COMUNICACIÓN ENTRE MOTOR / TRANSMISIÓN CAN-BUS 120Ω Engine ECU END USER
Trans. EST37
60Ω
E.C.U
E.C.U
120Ω
120Ω
120Ω
Can L
Can H
1 - Can H
2 - Can L
Codes 56-58, 65, 66, 69, 6A, 6B, 6E
Plug X4 22
MEDIDAS EN EL CAN-BUS USING DIGITAL MULTI-METER - RESISTANCE (Ω) IGNITION OFF. ALL CONTROLS HAVE TO BE CONNECTED MEASUREMENT BETWEEN
SPECIFIED VALUE
ACTUAL VALUE
CAN H (X4 PIN 1)
40 Ω
0Ω
40 Ω
60 Ω or 120 Ω
RED PROBE AND CAN L (X4 PIN 2) BLACK PROBE 40 Ω
33
☺Ω
POSSIBLE CAUSE S.C. FROM CAN H TO CAN L CONNECTION TO 1 or 2 END RESISTOR IS CUT OFF OR RESISTOR HAS FAILED END RESISTOR CUT OFF, DAMAGED OR CAN WIRE INTERRUPTED
MEDIDAS EN EL CAN-BUS USING DIGITAL MULTI-METER - VOLTAGE(V) IGNITION ON. ALL CONTROLS HAVE TO BE CONNECTED MEASUREMENT BETWEEN
SPECIFIED VALUE
ACTUAL VALUE 24 V
CAN H (X4 PIN 1) RED PROBE
2.4 V - 2.9 V
AND
0 V - 2.3 V 3.0 V - 24 V
GROUND - BLACK PROBE
24 V
CAN L (X4 PIN 2) RED PROBE AND GROUND - BLACK PROBE
44
0V
2.2 V - 2.7 V
0V 0 V - 2.1 V 2.8V - 24 V
POSSIBLE CAUSE S.C. FROM CAN H TO BATTERY S.C. FROM CAN H TO GROUND S.C. FROM CAN H TO AN AUXILIARY COMPONENT. S.C. FROM CAN L TO BATTERY S.C. FROM CAN L TO GROUND S.C. FROM CAN L TO AN AUXILIARY COMPONENT.
POSICIÓN DEL ACELERADOR Terex I.D. B19
REFER. TO ENGINE & COOLING TRAINING FOR DETAILED OPERATION.
FUNCIÓN GOLPEAR ABAJO FUNCTION; KICK-DOWN CAN ONLY BE EXECUTED IN AUTOMATIC MODE. KICK-DOWN ALLOWS THE OPERATOR TO DOWNSHIFT, PROVIDING THAT THE VEHICLE SPEED IS WITHIN A SAFE OPERATING RANGE. WHEN IN 2nd GEAR AUTOMATIC,THERE ARE 2 OPTIONS TO OBTAIN 1st GEAR; 1. MANUALLY SHIFT GEAR LEVER TO LEFT 2. USE KICK-DOWN OPERATION; S74 MAKES CONTACT POWER VIA F11 SIGNALS PLUG X7 PIN 16 (WIRE #422) ACTIVATES ECU PLUG X1 PIN 22
TRANSMISSION PILOT PRESSURE 16 bar+2 bar (232 psi)
99
TRABA DIFERENCIAL TRANSMISIÓN
Y7
10 10
INTERRUPTORES TRABA DIFERENCIAL & RETARDADOR D - Diff. Lock Request Switch (S60) R - Retarder Request Switch (S81)
D
R
1
1 - Diff. Lock Indicator Lamp Ref. Next Slide
2 - Not Used
2 Differential Lock Indicator Lamps
11 11
OPERACIÓN TRABA DIFERENCIAL OPERATOR WARNING
1
SYSTEM IS DESIGNED FOR POWERSHIFT DIFFERENTIAL LOCK IN BOTH TRANSMISSION AND AXLE. DIFFERENTIAL LOCK CAN BE MANUALLY ACTIVATED UP TO 3RD GEAR - ALL SPEEDS. WARNING! - CRITERIA FOR 4TH TO 6TH GEAR IS THAT TORQUE THROUGH TRANSMISSION MUST BE BELOW 400Nm. 4TH TO 6TH GEAR CRITERIA IS CONTROLLED VIA THE EST(TRANSMISSION ECU) SYSTEM TRANSMISSION ECU WILL NOT ACTIVATE SIGNAL TO DIFFERENTIAL LOCK IF TORQUE IS GREATER THAN 400Nm.
OPERATION; S60 SENDS REQUEST SIGNAL TO PLUG X7 PIN 8 TRANS. ECU RECEIVES REQUEST SIGNAL AT PLUG X1 PIN 30 (WIRE#430) TRANS. ECU DETERMINES DIFF. LOCK OPERATING PARAMETERS ARE OKAY. ACTUATION SIGNAL TO DIFF. LOCK SOLENOID IS SENT VIA PLUG X9 PINS 11 & 12
INTERRUPTOR RETARDADOR R - Retarder Request Switch (S81)
MANUAL RETARDER OPERATION(SWITCH ON); SELECT RETARDER REQUEST SWITCH (S81) PROVIDING THAT THE TRANSMISSION ‘STOP’ LAMP IS OUT, TRANSMISSION IS IN LOCK-UP, FOOT IS OFF GAS AND THE TRANSMISSION OIL TEMP. IS WITHIN OPERATING RANGE - A RETARDER APPLY WILL BE MADE.
R
WARNING/FAULTS CODES; WS SUMP TEMP. WARNING WR RETARDER TEMP. WARNING WE HIGH ENGINE SPEED WARNING B7
HIGH SUMP TEMP. FAULT
B8
HIGH RETARDER TEMP. FAULT
19 19
AUTOMATIC RETARDER OPERATION(SWITCH OFF); APPROACHING AN OVER-SPEED CONDITION, THE TRANSMISSION WILL AUTOMATICALLY UP-SHIFT TO DECREASE ENGINE RPM. WITH THE ACCELERATOR PEDAL RELEASED (OFF GAS), THE RETARDER WILL AUTOMATICALLY APPLY WHEN VEHICLE SPEED REACHES 2000 RPM AND WILL DIS-ENGAGE AT 1850 RPM. THE RETARDER WILL AUTOMATICALLY DIS-ENGAGE WHEN TRANSMISSION OIL TEMPERATURE REACHES 150°C (300°F). VEHICLE SPEED MUST BE REDUCED USING SERVICE BRAKES. WITH THE ACCELERATOR APPLIED (ON GAS), THE RETARDER WILL AUTOMATICALLY APPLY AT 2600 RPM AND DIS-ENGAGE AT 2450 RPM. ABNORMAL OPERATION WILL ACTIVATE TRANSMISSION FAULT CODES THAT WILL BE DISPLAYED AND RECORDED BY THE ECU.
OPERATION; PEDAL POTENTIOMETER WORKS ON 0 TO 5 V SCALE. RELAYS ARE ACTIVATED WHEN PEDAL POTENTIOMETER >1V. THIS ALLOWS 24V (FUSED) FROM BUSBAR TO ACTIVATE APPROPRIATE SOLENOIDS AND LAMPS. RELAYS ARE DE-ACTIVATED WHEN PEDAL POTENTIOMETER 50°C &