Zamil Steel Design Manual

October 3, 2017 | Author: Ayubkhan2 | Category: Framing (Construction), Crane (Machine), Screw, Beam (Structure), Structural Engineering
Share Embed Donate


Short Description

steel design manual...

Description

PEB DIVISION

ZAMIL STEEL COMPANY LIMITED PRE-ENGINEERED BUILDINGS DIVISION

DESIGN MANUAL D M

03 . 10 .0 0

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

P R E F AC E

This revision of design manual has been prepared to account for the changes of ZAMIL STEEL standards during the last four years since 1999 regarding single skin & Tempcon panels, built-up sections standard dimensions, serviceability consideration and some standard connections, also this revision of design manual presents the results of special technical studies carried out in the ZAMIL STEEL PRD department including finite element studies using most recent software techniques, buckling analysis studies and also derived formulas using numerical correlation studies. Designers can make use of these studies to enhance the design process. This revision of the design manual also resolves some miscellaneous and confusing points that were reported to PRD department. The contents of this manual were rearranged and presented in “Adobe Acrobat” format along with navigation pane to ensure effective and fast use of this manual. Design/Quote engineers are strongly advised to read this manual as a whole in conjunction with the standard codes and manuals stated in clause 2.1 page 2-1 of this manual. The clauses containing the major changes made in this revision of design manual (DM 03.10.00) are as follows :2.4. Serviceability consideration _________ 2-15 3.5. Expansion Joints __________________ 3-8 3.7. Bracing Systems Arrangement_______ 3-11 4.1.2.1. Built up section _________________ 4-3 4.1.2.2. Galvanized primary members______ 4-5 4.3. Flange braces____________________ 4-22 4.6. Standard Anchor Bolts _____________ 4-67 4.7.8. Crane Beam ___________________ 4-74 5.1. Panels___________________________ 5-1 5.2.1.7. Double ‘C’ -sections ____________ 5-27 5.2.2. Design Of Roof Purlins ___________ 5-29 5.2.4. Design Of Eave Struts ____________ 5-35 6.1.2. End wall Rafter Design Concept _____ 6-2 6.2.2. End Wall Posts Design Concept _____ 6-6 7.2.3.1 Top Running Cranes ____________ 7-11 7.3. Bracing Design Notes ______________ 7-13

DM 03.10.00

I

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

P R E F AC E

8.2.1.2.Connection for Lateral Load _______ 8-2 9.1. Design of Joists ___________________ 9-2 9.3. Design of Beams __________________ 9-7 10.11. Egypt Jobs in Non-Free Zone Areas 10-6 12.1. Drainage ______________________ 12-1

Your feedback and comments are highly appreciated for the continuous improvement of this manual.

MTS AAG OCT. 2003

DM 03.10.00

II

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

RESPONSIBILLITIES

Design Engineer’s Responsibilities: 1. Reports to his Design Supervisor. 2. Studies and validates contract requirements, given in the Contract Information Form (CIF) and raises queries and requests for clarifications as necessary. 3. Designs buildings assigned to him using design codes, specifications, procedures and standards of Zamil Steel together with engineering rationale. 4. Designs all building components satisfying the stability, serviceability and stress requirements simultaneously under design loads and load combinations. 5. Optimizes the design by utilizing optimizing techniques in order to achieve the most economical and an adequate design. 6. Plans to finish his work according to the schedules and deadlines assigned. Gives early warning to his supervisor if the schedules cannot be met. 7. Alerts his supervisor in cases such as special design requirements and non-standard building configuration. 8. Gives clear instructions to detailing engineers on his jobs in order to make sure that his designs are understood. 9. Reviews approval and erection drawings and gives final approval on them. 10. Checks other design engineer’s work if checking is assigned to him. 11. Participates in design meetings and suggests improvement of design engineering practices. Quote Design Engineer’s Responsibilities: The engineer designing a quote should be efficient in his work. He is required to cope up with the design accuracy as well as the speed at the same time. His task is not limited only to the design of the building as it is presented in the C.I.F. Beyond this; he should suggest the optimal building configuration and come up with the most economical design as well. The ideal and the professional approach that is required from the quote design engineer is summarized below: 1. Go over the CIF and thoroughly absorb what is requested in terms of dimensions, design loads, special details etc. 2. Think of the best possible solution that will provide the same shape of the building, but may be with different bay spacing, different type of frames, different frame orientations, etc. which will produce the most economical design of the building. 3. Contact the sales representative in charge of the quote and discuss alternative solutions (if any). 4. If approved, design the quotation accordingly and mention the deviations, additions and deletions clearly in his design summary. 5. The guidelines regarding planning a PEB in order to reach the best and most competitive offer are outlined in chapter 3.

DM 03.10.00

III

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

T AB L E O F C O N T E N T

CHAPTER 1: MATERIALS ....................................................................................................................................... 1-1 1.1. PLATES ......................................................................................................................................................... 1-1 1.2. COLD FORMED SECTIONS.......................................................................................................................... 1-1 1.3. HOT ROLLED SECTIONS ............................................................................................................................. 1-2 1.4. SHEETING ..................................................................................................................................................... 1-2 1.5. SKYLIGHT PANELS...................................................................................................................................... 1-3 1.6. TRIMS ............................................................................................................................................................ 1-3 1.7. ROUND BARS ............................................................................................................................................... 1-3 1.8. CABLE BRACING ......................................................................................................................................... 1-3 1.9. ANCHOR BOLTS........................................................................................................................................... 1-3 1.10. MISCELANEOUS ........................................................................................................................................ 1-4 1.11. BOLTS ......................................................................................................................................................... 1-4 1.12. NUTS............................................................................................................................................................ 1-4 1.13. WASHERS ................................................................................................................................................... 1-5 1.14. SELF DRILLING SCREWS.......................................................................................................................... 1-5 1.15. RIVETS......................................................................................................................................................... 1-6 CHAPTER 2: STANDARD CODES & LOADS......................................................................................................... 2-1 2.1. STANDARD CODES AND M ANUALS .................................................................................................................... 2-1 2.2. DESIGN LOADS ................................................................................................................................................. 2-2 2.2.1. Dead Load .............................................................................................................................................. 2-2 2.2.2. Live Loads & Collateral Loads ................................................................................................................ 2-3 2.2.3. Roof Snow Load ..................................................................................................................................... 2-4 2.2.4. Wind Load............................................................................................................................................... 2-7 2.2.5. Crane Loads ........................................................................................................................................... 2-8 2.2.6. Seismic Loads ...................................................................................................................................... 2-11 2.3. LOAD COMBINATIONS ..................................................................................................................................... 2-13 2.4. SERVICEABILITY CONSIDERATION .................................................................................................................... 2-15 CHAPTER 3: PLANNING PEB.................................................................................................................................3-1 3.1. M AIN FRAME CONFIGURATION ..........................................................................................................................3-1 3.1.1. Main frame orientation ............................................................................................................................3-1 3.1.2. Main frame types ....................................................................................................................................3-2 3.1.2.1 Clear Span ........................................................................................................................................................ 3-2 3.1.2.2. Multi - Span...................................................................................................................................................... 3-2 3.1.2.3. Lean- T0........................................................................................................................................................... 3-3 3.1.2.4. Mono- slope ..................................................................................................................................................... 3-4 3.1.2.5. Space Saver .................................................................................................................................................... 3-4 3.1.2.6. Roof System..................................................................................................................................................... 3-5 3.1.2.7. Multi- Gable...................................................................................................................................................... 3-6

3.1.3. Roof Slope ..............................................................................................................................................3-6 3.1.4. Eave Height ............................................................................................................................................3-7 3.2. ROOF PURLINS .................................................................................................................................................3-7 3.3. WALL GIRTS ....................................................................................................................................................3-7 3.4. END W ALL SYSTEMS ........................................................................................................................................3-8 3.5. EXPANSION JOINTS ..........................................................................................................................................3-8 3.6. BAY SPACING ..................................................................................................................................................3-9 3.7. BRACING SYSTEMS ARRANGEMENT ................................................................................................................3-11 3.7.1. Bracing for wind and seismic loads in the longitudinal direction ..........................................................3-11 3.7.2. Wind and seismic bracing in P&B endwalls..........................................................................................3-12 3.7.3. Crane Bracing .......................................................................................................................................3-12 3.8. MEZZANINE FLOORS .......................................................................................................................................3-13 3.9. CRANES SYSTEMS ..........................................................................................................................................3-14

DM 03.10.00

IV

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

T AB L E O F C O N T E N T

CHAPTER 4: MAIN FRAMING DESIGN ................................................................................................................. 4-1 4.1. M AIN FRAME DESIGN PROCEDURE AND CONSTRAINTS ...................................................................................... 4-1 4.1.1. ASFAD ................................................................................................................................................... 4-1 4.1.2. Design Constraints................................................................................................................................. 4-3 4.1.2.1. Built up section ................................................................................................................................................ 4-3 4.1.2.2. Galvanized primary members .......................................................................................................................... 4-5 4.1.2.3. Fabrication Limitation....................................................................................................................................... 4-6 4.1.2.4. Shipping Limitation .......................................................................................................................................... 4-7 4.1.2.5. Shot Blast and Paint Line Limitations .............................................................................................................. 4-7 4.1.2.6. Other guidelines............................................................................................................................................... 4-8 4.1.2.7. Optimization..................................................................................................................................................... 4-9

4.2. DESIGN OF JACK BEAMS................................................................................................................................ 4-11 4.2.1. Loads ................................................................................................................................................... 4-11 4.2.2. Connection details................................................................................................................................ 4-12 4.2.3. Design parameters............................................................................................................................... 4-12 4.2.4. Design Procedure ................................................................................................................................ 4-13 4.3. FLANGE BRACES ........................................................................................................................................... 4-22 4.3.1. Brace members requirements.............................................................................................................. 4-22 4.3.1.1. Stiffness requirements ................................................................................................................................... 4-22 4.3.1.2. Strength requirements ................................................................................................................................... 4-23

4.3.2. Spread sheet for checking flange brace system adequacy ................................................................. 4-24 4.4. DESIGN OF RIGID FRAME CONNECTIONS ......................................................................................................... 4-28 4.4.1. Design of Pinned Base Plate ............................................................................................................... 4-28 4.4.2. Design of Fixed Base Plate.................................................................................................................. 4-40 4.4.3. Design of horizontal knee connection .................................................................................................. 4-47 4.4.4. Design of rafter intermediate & ridge splices ....................................................................................... 4-54 4.4.5 Design of Pinned Cap Plate.................................................................................................................. 4-55 4.5. STANDARD FRAME CONNECTIONS CODES ...................................................................................................... 4-58 4.5.1 Anchor Bolt Pattern Codes ................................................................................................................... 4-58 4.5.2 Knee Connections................................................................................................................................. 4-64 4.5.3 Rafter Splice Codes .............................................................................................................................. 4-65 4.6. STANDARD ANCHOR BOLTS ........................................................................................................................... 4-67 4.7. WELDING PROCEDURE ................................................................................................................................... 4-69 4.7.1.Types of Welds and Standard Sizes..................................................................................................... 4-69 4.7.2. Main Frame with Horizontal Knee Connection .................................................................................... 4-70 4.7.3. Vertical Knee Connection .................................................................................................................... 4-71 4.7.4. Interior Columns Connections.............................................................................................................. 4-71 4.7.5. Ridge Splices ....................................................................................................................................... 4-72 4.7.6. Base Plate of Cold-Formed EW Post .................................................................................................. 4-72 4.7.7. Mezzanine Connections....................................................................................................................... 4-73 4.7.8. Crane Beam ......................................................................................................................................... 4-74

CHAPTER 5: SECONDARY MEMBERS DESIGN...................................................................................................5-1 5.1. PANELS ............................................................................................................................................................5-1 5.1.1. Single Skin Panels ..................................................................................................................................5-1 5.1.1.1. Steel Panels .....................................................................................................................................................5-1 5.1.1.2. Aluminum Panels..............................................................................................................................................5-8

5.1.2. Tempcon Panels ...................................................................................................................................5-10 5.1.2.1. Steel Tempcon Panels....................................................................................................................................5-11 5.1.2.2. Aluminum Tempcon Panels............................................................................................................................5-16

5.2. SECONDARY STRUCTURAL FRAMING ...............................................................................................................5-20 5.2.1. Cold Formed Cross Sections Properties and Capacities .....................................................................5-21 5.2.1.1. 200mm depth Z-sections ................................................................................................................................5-21 5.2.1.2. 250mm depth Z-sections ................................................................................................................................5-22 5.2.1.3. Z-sections overlaps.........................................................................................................................................5-23 5.2.1.4. 120mm depth C-sections................................................................................................................................5-24 5.2.1.5. 200mm depth C-sections................................................................................................................................5-25 5.2.1.6. 300mm depth C-sections................................................................................................................................5-26

DM 03.10.00

V

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

T AB L E O F C O N T E N T 5.2.1.7. Double ‘C’ -sections........................................................................................................................................5-27 5.2.1.8. Eave Strut-section ..........................................................................................................................................5-28

5.2.2. Design Of Roof Purlins .........................................................................................................................5-29 5.2.2.1 Roof Purlins design loads ................................................................................................................................5-29 5.2.2.2. Roof Purlins design concept ...........................................................................................................................5-29 5.2.2.3. Roof Purlins connections ................................................................................................................................5-32

5.2.3. Design Of Wall Girts ............................................................................................................................5-33 5.2.3.1. Wall Girts Design Loads .................................................................................................................................5-33 5.2.3.2. Wall Girt Design Concept: ..............................................................................................................................5-33 5.2.3.3. Wall Girt Connections .....................................................................................................................................5-34

5.2.4. Design Of Eave Struts ..........................................................................................................................5-35 5.2.4.1. Eave strut Design Loads.................................................................................................................................5-35 5.2.4.2. Eave strut Design Concept: ............................................................................................................................5-35 5.2.4.3. Eave Strut Connections: .................................................................................................................................5-36

CHAPTER 6: END WALLS DESIGN ........................................................................................................................6-1 6.1. POST & BEAM ENDWALL RAFTERS ...................................................................................................................6-1 6.1.1. Design Loads: .........................................................................................................................................6-2 6.1.2. Design Concept.......................................................................................................................................6-2 6.1.3. End Wall Rafter Guide Design Tables ....................................................................................................6-3 6.2. ENDWALL POSTS ..............................................................................................................................................6-6 6.2.1. Design Loads: .........................................................................................................................................6-6 6.2.2. Design Concept.......................................................................................................................................6-6 6.2.3. End Wall Rafter Guide Design Tables ....................................................................................................6-8 6.3. END W ALL DESIGN SOFT WARE ........................................................................................................................6-9 6.4. DIAPHRAGM ACTION AT P&B END W ALLS .......................................................................................................6-11 CHAPTER 7: BRACING SYSTEM DESIGN............................................................................................................ 7-1 7.1. BRACING STRUCTURAL TYPES ......................................................................................................................... 7-1 7.1.1. X-bracing................................................................................................................................................ 7-1 7.1.2. Portal Bracing:........................................................................................................................................ 7-2 7.1.3. Minor Axis Bending ................................................................................................................................ 7-3 7.2. BRACING SYSTEMS .......................................................................................................................................... 7-4 7.2.1. Wind Bracing.......................................................................................................................................... 7-4 7.2.1.1. Longitudinal bracing:........................................................................................................................................ 7-4 7.2.1.2. Transversal bracing in P&B end walls ............................................................................................................. 7-8

7.2.2. Seismic Bracing ..................................................................................................................................... 7-9 7.2.2.1.Sidewall bracing X-bracing ............................................................................................................................... 7-9 7.2.2.2.Sidewall bracing Portal Bracing ...................................................................................................................... 7-10

7.2.3. Crane Bracing ...................................................................................................................................... 7-11 7.2.3.1 Top Running ................................................................................................................................................... 7-11 7.2.3.2 Underhung...................................................................................................................................................... 7-12

7.3. BRACING DESIGN NOTES ............................................................................................................................... 7-13 CHAPTER 8: CRANE SYSTEMS DESIGN ..............................................................................................................8-1 8.1. CRANES SYSTEMS DESIGN RULES: ...................................................................................................................8-1 8.2. DIFFERENT CRANE TYPES .................................................................................................................................8-2 8.2.1. Top Running Cranes ...............................................................................................................................8-2 8.2.1.1. Bracket System.................................................................................................................................................8-2 8.2.1.2.Connection for Lateral Load ..............................................................................................................................8-2 8.2.1.3. Independent Crane Column..............................................................................................................................8-3 8.2.1.4. Stepped Column...............................................................................................................................................8-4 8.2.1.5. Crane Tower .....................................................................................................................................................8-5 8.2.1.6. Crane Beam Design .........................................................................................................................................8-8

8.2.2. Under hung Cranes / Monorails ............................................................................................................8-12 8.2.3. Jib Cranes: ............................................................................................................................................8-13 8.2.4 Gantry Cranes & Semi-gantry................................................................................................................8-15

DM 03.10.00

VI

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

T AB L E O F C O N T E N T CHAPTER 9: MEZZANINE FLOOR DESIGN...........................................................................................................9-1 9.1. DESIGN OF JOISTS ............................................................................................................................................9-2 9.2. DESIGN OF JOISTS CONNECTIONS .....................................................................................................................9-4 9.3. DESIGN OF BEAMS............................................................................................................................................9-7 9.4. DESIGN OF BEAMS CONNECTIONS .....................................................................................................................9-9 9.5. DESIGN OF COLUMNS .....................................................................................................................................9-14 9.6. DESIGN OF FLOORING .....................................................................................................................................9-16 9.6.1 Mezzanine Deck.....................................................................................................................................9-16 9.6.2. Chequered Plate ...................................................................................................................................9-16 9.6.3. Gratings.................................................................................................................................................9-17 9.7.MISCELLANEOUS ITEMS ...................................................................................................................................9-18 9.7.1. Staircases .............................................................................................................................................9-18 9.7.2. Handrails ...............................................................................................................................................9-18 9.8. SPECIAL CASES..............................................................................................................................................9-19 9.8.1. Roof Platforms ......................................................................................................................................9-19 9.8.2. Catwalk .................................................................................................................................................9-19 9.9. FLOOR VIBRATION...........................................................................................................................................9-20 9.9.1. Vibration due to heel drop impact .........................................................................................................9-20 9 9 2 Vibration due to forcing impact 9-28 CHAPTER 10: SPECIAL DESIGN REQUIREMENTS............................................................................................10-1 10.1. ROYAL COMMISSION:....................................................................................................................................10-1 10.2. SAUDI CONSOLIDATED ELECTRICITY COMPANY (SCECO): ............................................................................10-1 10.3. SAUDI ARAMCO:...........................................................................................................................................10-1 10.4. JEBEL ALI FREE ZONE AUTHORITY (JAFZA).................................................................................................10-2 10.5. DUBAI ..........................................................................................................................................................10-4 10.6. SHARJAH .....................................................................................................................................................10-4 10.7. ABU DHABI...................................................................................................................................................10-5 10.8. VIETNAM: .....................................................................................................................................................10-5 10.9. SHANGHAI CHINA: ........................................................................................................................................10-5 10.10. WIND SPEED IN SAUDI ARABIAN: .................................................................................................................10-5 10.11. EGYPT JOBS IN NON-FREE ZONE AREAS .....................................................................................................10-6 10.12. SNOW LOADS .............................................................................................................................................10-6 CHAPTER 11: SPECIAL BUILDINGS....................................................................................................................11-1 11.1. CAR CANOPIES.............................................................................................................................................11-1 11.2. POULTRY BUILDINGS ....................................................................................................................................11-6 11.3. BULK STORAGE BUILDINGS ..........................................................................................................................11-8 11.4. HANGAR BUILDINGS ...................................................................................................................................11-13

CHAPTER 12: MISCELLANEOUS SERVICES......................................................................................................12-1 12.1. DRAINAGE ...................................................................................................................................................12-1 12.2. NATURAL LIGHTING ......................................................................................................................................12-7 12.3. VENTILATION ..............................................................................................................................................12-10 12.3.1. Ventilation Design Using Air Change Method...................................................................................12-11 12.3.2. Ventilation Design Using Heat Removal Method..............................................................................12-12 12.4. FOOTING .................................................................................................................................................12-14 12.4.1. Spread Footings with hairpin ............................................................................................................12-15 12.4.2 Spread Footings without hairpin ........................................................................................................12-23

DM 03.10.00

VII

ZAMIL STEEL BUILDINGS DESIGN MANUAL 1. Materials

PEB DIVISION

CHAPTER 1: MATERIALS Pre-engineered buildings (PEB) system mainly makes use of built-up sections, cold formed members as well as some hot rolled sections. The materials of these components conform to ASTM (American Society for Testing and Materials) specifications or equivalent standards. The specifications of materials are updated as per the current usage and available inventory. In the following table, type, order size, usage and material specifications are listed for each component of pre-engineered buildings in order to facilitate design.

1.1. PLATES Thickness (mm) 4.0 5.0 6.0 8.0 10.0 12.0 15.0 20.0 25.0 30.0 40.0 50.0

ORDER SIZE

USAGE

1500mm W x 6000mm L 1500mm W x 6000 mm L 1500mm W x 6000mm L

Webs of built-up sections Webs & Flanges of built-up sections

2100mm W x 6000mm L

SPECIFICATIONS

Webs and Flanges of built-up sections Webs and Flanges of built-up sections, Connection plates

ASTM - A 572 M GRADE 345 Type 1

Flanges of built-up sections

Fy = 34.5 kN/cm2 Fu = 45 kN/cm2

2100mm W x 6000mm L Connection Plates 2000mm W x 6000mm L

Connection Plates

1.2. COLD FORMED SECTIONS TYPE

SECTIONS

ORDER SIZE

BLACK COIL

200Z15 200Z17 200Z20 200Z22 200Z25 200Z30 180C20 180C25 200C20

COIL 1.5mm T x 345mm W COIL 1.75mm T x 345mm W COIL 2.0mm T x 345mm W COIL 2.25mm T x 345mm W COIL 2.5mm T x 345mm W COIL 3.0mm T x 345mm W COIL 2.0mm T x 390mm W COIL 2.5mm T x 390mm W COIL 2.0mm T x 390mm W

200C25

COIL 2.5mm T x 390mm W

300C2.0 200Z15 200Z17 200Z20 200Z22 200Z25 180C20 180C25 200C20 200C25

COIL 2.0mm T x 495mm W COIL 1.5mm T x 345mm W COIL 1.75mm T x 345mm W COIL 2.0mm T x 345mm W COIL 2.25mm T x 345mm W COIL 2.50mm T x 345mm W COIL 2.0mm T x 390mm W COIL 2.5mm T x 390mm W COIL 2.0mm T x 390mm W COIL 2.5mm T x 390mm W

120C20 120C25 120C30

COIL 2.0mm T x 260mm W COIL 2.5mm T x 260mm W COIL 3.0mm T x 260mm W

GALVANIZED

NARROW COILS GALVANIZED

DM 03.10.00

USAGE

SPECIFICATIONS

Purlins & Girts

Eave Struts

ASTM-A607 GRADE 50 (For Red Oxide Primed) Fy = 34.5 kN/cm2

End wall Rafters, F. Openings, Eave Struts, Wind Columns & Mezzanine joists

Purlins & Girts

Eave Struts

ASTM A653 SQ50 Class 1 (Galvanized) Fy = 34.5 kN/cm2

End Wall Rafters, Eave Struts, Framed Openings & Wind Columns Space Frame Chored Members & Slide Door Leaves

1-1

ZAMIL STEEL BUILDINGS DESIGN MANUAL 1. Materials

PEB DIVISION

1.3. HOT ROLLED SECTIONS TYPE I SECTIONS

ORDER SIZE

USAGE Wind Columns, Endwall Rafters & Mezzanine Joists

IPEa 200 x 18.4 x 12.0m L TUBES

150 mm x 150mm x 4.5mm x 12.0m L 200mm x 200mm x 6.0mm x 12.0m L

CHANNEL ANGLES

PIPES Galvanized

120mm x 60mm x 5.0mm x 8.5m L PFC 200 x 75 x 23 x 9.0m L PFC 260 x 75 x 28 x 9.0m L PFC 380 x 100 x 54 x 9.0m L 40mm x 40mm x 3.0mm x 12.0m L 50mm x 50mm x 3.0mm x 12.0m L 60mm x 60mm x 4.0mm x 12.0m L 60mm x 60mm x 5.0mm x 12.0m L 60mm x 60mm x 6.0mm x 12.0m L 75mm x 75mm x 6.0mm x 12.0m L 100mm x 100mm x 8.0mm x 12.0m L 42mm x 2.3mm x 6.6m L 48mm x 2.8mm x 6.6m L 89mm x 2.8mm x 6.6m L

Rigid Frame and Mezzanine Columns

SPECIFICATIONS JIS-G3101 SS540 or 10025- S355JR Fy = 34.5 kN/cm2

EN

JIS-3466 STKR-490 Fy = 32.5 kN/cm2

Space Frame Truss Members Cap Channel for Crane Beams, Stringer for Staircase

Flange Bracing, X Bracing and Open Web Joist Members Hand Rails/Space Frame Diag. Memb. Space Frame Diagonal Members

EN10025-S355JR Fy = 35.5 kN/cm2

ASTM 572 Grade 50 Fy = 34.5 kN/cm2

JIS-G-6344-STK500 Fy = 35.5 kN/cm2

L: Length, W: Width, T: Thickness

1.4. SHEETING Panel Type

Type A ( Hi-Rib)

Finish/Color Bare Zincalume

Type G (Deep Rib) Type R

Order Size

0.5 0.6 0.7

Type B (Hi-Rib+)

Type C (Lo-Rib)

Thickness

XRW Painted Z/A All Standard Colors

0.5

XRW Painted Z/A Frost White XPD Painted Z/A Frost White

0.6 0.7 0.5 0.6 0.7

Aluminum Plain

Coil 1145 mm W

USAGE Type A: Sheeting Panels for Roof, Walls, Mezzanine Deck, Partitions & Liners Type B: Sheeting Panels for Roof, Walls, Partitions & Liners Type C: Liners Sliding Doors, Top & Bottom Layer of TCLR, Bottom Layer of TCHR Type G: Mezzanine Deck & Roof Sheeting Type R: Sheeting Panels for Walls, Partitions & Liners

XRW Painted Z/A Frost White Bare Zincalume

Type F (5-Rib)

XRW Painted Z/A Frost White XPD Painted Z/A Frost White Aluminum Plain Aluminum Frost White

DM 03.10.00

0.5 0.5 0.6 0.5 0.6 0.7 0.5 0.6 0.7 0.70

ASTM - A 792 M GRADE 345 B Coating AZ150 Fy = 34.5 kN/cm2

Alloy Type AA3003 H26 Fy = 16.15 kN/cm2

0.70

Aluminum Frost White Type D & E (Sculptured Panel)

SPECIFICATIONS

Coil 411 mm W

Coil 1278 mm W

Partitions, Liners and Soffit Panels

Top Layer of TCHR in Roof and Walls

ASTM-A792 GRADE 50B Coating AZ150 Fy = 34.5 kN/cm2

ASTM-A792 GRADE 50B Coating AZ150 Fy = 34.5 kN/cm2

Alloy Type AA3003 H26 Fy = 16.15 kN/cm2

1-2

ZAMIL STEEL BUILDINGS DESIGN MANUAL 1. Materials

PEB DIVISION

1.5. SKYLIGHT PANELS Panel Type

Order Lengt h

Type A ( Hi-Rib) 3250 mm

Type B (Hi-Rib) Type F (5 Rib)

2750 mm 3250 mm

Type G (Deep Rib) Type R

USAGE

SPECIFICATIONS

Translucent Panels for Roof, Walls Translucnet Panels for Roof, Walls Translucent Panels for Roof, Walls Translucent Panels for Roof, Walls

ASTM D 3841-86 Type I Tensile Strength = 10.3kN/cm2, Flexural Strength = 20.7kN/cm2

Translucent Panels for Walls

1.6. TRIMS TYPE EAVE TRIM CORNE TRIM R GABLE TRIM DOWN SPOUTS GUTTERS VALLEY GUTTERS

COLOR Frost White Bronze Brown

ORDER SIZE COIL 0.5mm T x 288mm W

Frost White Bronze Brown Frost White Bronze Brown All Standard Colors Zinc / Alum

COIL 0.5mm T x 326mm W

SPECIFICATIONS

ASTM - A792 M GRADE 345B Fy = 34.5 kN/cm2

COIL 0.5mm T x 350mm W COIL 0.5mm T x 563mm W COIL 1.0mm T x 1145mm W

1.7. ROUND BARS ROD DIAMETER

ORDER LENGTH

USAGE

SPECIFICATIONS

12.0m

As Sag Rods X-Bracing in Roof and Walls

ASTM - A 615M GRADE 300 Fy = 27.7 kN/cm2

16mm 24mm

1.8. CABLE BRACING Strand Diameter 1 / 2 inch (12.70 mm)

ORDER DESCRIPTION Zinc Coated, 7-wire strand 6 Wire layer eccentrically twisted over one center wire Coil

USAGE Cable Bracing in Roof and Walls

Additional Items:

M24 Eye Bolt Brace Grip 1/2" Diameter x 970mm L

SPECIFICATIONS ASTM - A475 - CLASS A Extra High Strength Breaking Load = 119.7 kN Class 4.6 Electro Galvanized ASTM - A475-78 - CLASS A

L: Length, W: Width, T: Thickness

1.9. ANCHOR BOLTS BOLT DIAMETER (mm) M16

ORDER LENGTH (mm) 400mm

M20 M24 M30 M36

500mm 600mm 900mm 1000mm

DM 03.10.00

USAGE

SPECIFICATIONS

Anchor bolts for End Wall & Partitions Column bases Anchor Bolts for Main Frame & Mezzanine column bases

ASTM A36M or JIS-G 3101 - SS 400 Type J Hot Dip Galvanized Fy = 23.5 kN/cm2

1-3

ZAMIL STEEL BUILDINGS DESIGN MANUAL 1. Materials

PEB DIVISION

1.10. MISCELANEOUS TYPE Slide Door Rails CHEKERED PLATE GRATINGS

ROLL-UP DOOR GUIDE GUIDE KITS

ORDER SIZE Rails (SD/DSD) x 6000 mm L CH.PL. 5mm T x 2000mm W x 6000mm L PLAIN GALVANIZED GRAITING

USAGE Door Rail Tracks

BAR 30mm x 3mm @ 30mm CENTER and Twisted BAR 100mm PITCH x 995mm W x 6000mm L 5000 mm HEIGHT - RIGHT 5000 mm HEIGHT - LEFT 4000 mm HEIGHT - RIGHT 4000 mm HEIGHT - LEFT TOP TRACK 2.0mm T x 6000mm L BOTTOM TRACK 3.0mm T x 6000mm L BOTTOM TRACK 4.0mm T x 6000mm L

SPECIFICATIONS ASTM - A 1 ASTM - A 36 Fy = 22.0 kN/cm2

Floors in Catwalks, Mezzanine & Platforms

EN 10025 GRADE 275

Door Guide For Roll-Up Doors Sliding Door T1, T2 Guides Sliding Door B1 Guides Sliding Door B1 Guides

Australian Standards AS-3902

BS - 2989

1.11. BOLTS BOLT DIAMETER (mm) M12 M12

ORDER LENGTH

USAGE

SPECIFICATIONS

Secondary Connections Purlins & Girts Eave Strut, P&B Frame Connections

DIN 933 Class 4.6 Yellow Chromate Fully Threaded DIN 933 Class 8.8 HDG Fully Threaded Bolt and Nut

Connections of Primary Sections

ASTM - A 325 M Type 1 HDG Fully Threaded Bolt and Nut

35

M6

35 55 50 70 60 80 70 90 90 110 110 120 16

M12

36

Framed Openings

M12

25

Sliding Doors

M16 M20 M24 M27 M30

Other Moment Connections

Ridge Ventilator & Valley Gutters

DIN 933 Class 4.6 Stove Bolt Elec. Galvanized Fully Threaded DIN 933 Class 4.6 Fin Necked Bolt Elec. Galvanized, Fully Threaded DIN 933 Class 4.6 Countersunk Bolt Elec. Galvanized, Fully Threaded

L: Length, W: Width, T: Thickness

1.12. NUTS Nut Diameter (mm) M12 M16 M20 M24 M30 M36 M12 M16 M20 M24 M27

USAGE

SPECIFICATIONS

Secondary Connections - Machine Bolt For Anchor Bolts

DIN 934 Class 5 Yellow Chromate

For Cable Bracing & Anchor Bolts For Anchor Bolts

DIN 934 Class 5 Electro Galvanized Hex. Nut

DIN 934 Class 8 HDG High Strength Nut for Main Connections

ASTM – A563M HDG Hexagonal Nut

For Machine Bolts with Valley Gutters & Ridge Ventilator

DIN 934 Class 5 Elec. Galvanized Hex. Nut

M30 M6

DM 03.10.00

1-4

ZAMIL STEEL BUILDINGS DESIGN MANUAL 1. Materials

PEB DIVISION

1.13. WASHERS Washer Diameter (mm) M16 M20 M24 M30 M36 M12 M16 M20 M24 M27 M30

USAGE

SPECIFICATIONS

For Anchor Bolts DIN 125 Type A Flat Mild Elec. Galvanized

For Anchor Bolts & Cable Bracing For Anchor Bolts

ASTM - F436 Type 1 Round Hard

For High Strength Bolt of Main Connections

ASTM - A48 M Class275 B Cast Iron HDG Hill Side Washer DIN 125 Type A Flat Mild Elect. Galvanized

M24

Bracing System

M12

For Sliding Doors

M6

For Machine Bolt with Valley Gutters & Ridge Ventilator

1.14. SELF DRILLING SCREWS Description SDS Dacromet #5.5x25 SDS Dacromet #5.5x57 SDS Dacromet #5.5x32 SDS Dacromet #4.8x20 SDS Dacromet #5.5x62 SDS Dacromet #5.5x77 SDS Dacromet #5.5x107 SDS Dacromet #5.5x137 SDS Buildex #5.5x25 SSD Stainless Steel Screw #5.5x28 SSD Stainless Steel Screw 5.5x40 SSD Stainless Steel Screw 4.8x20 SSD Stainless Steel Screw 5.5x65 SSD Stainless Steel Screw 5.5x62 SSD Stainless Steel Screw 5.5x77 SSD Stainless Steel Screw 5.5x107 SSD Stainless Steel Screw 5.5x130

DM 03.10.00

Specifications SPEDEC SD5 T15-5.5 x 25mm

Usage Single skin roof fixed at low rib

SPEDEC SD5 T15-5.5x57mm

Single skin roof fixed at high rib, gutter strap

SPEDEC SD12-5.5x32mm

Mezzanine deck, hot rolled sections

SPEDEC SL2-T-A14-4.8x20 SPEDEC SD5 T15-5.5 x 62mm

Stitch screws for fastening panel to panel (side lap), panel to trims TCHR-65, TCMD-35, TCLR-35

SPEDEC SD5 T15-5.5 x 77mm

TCHR-80, TCMD-50, TCLR-50

SPEDEC SD5 T15-5.5 x 107mm

TCHR-105, TCMD-75, TCLR-75

SPEDEC SD5 T15-5.5 x 137mm

TCHR-130, TCMD-100, TCLR-100

Buildex 12-14x25mm No.6310-04813CS SSD Stainless Steel Screw #5.5x28

Single Skin non-roof

SSD Stainless Steel Screw 5.5x40 SSD Stainless Steel Screw 4.8x20 SSD Stainless Steel Screw 5.5x65

Stainless steel single skin fixed at low rib Stainless steel screws for mezzanine deck, hot rolled sections Stainless steel stitch screws

SSD Stainless Steel Screw 5.5x62

Stainless steel screws single skin roof fixed at high rib, gutter strap TCHR-65, TCMD-35, TCLR-35

SSD Stainless Steel Screw 5.5x77

TCHR-80, TCMD-50, TCLR-50

SSD Stainless Steel Screw 5.5x107

TCHR-105, TCMD-75, TCLR-75

SSD Stainless Steel Screw 5.5x130

TCHR-130, TCMD-100, TCLR-100

1-5

ZAMIL STEEL BUILDINGS DESIGN MANUAL 1. Materials

PEB DIVISION

1.15. RIVETS Description Pop Rivet Zinc Coated 1/8”

Specifications SD46BS

Pop Rivet Bronze Brown 1/8”

SD46BS

Stainless Steel Pop Rivet 1/8”

SSD46SSBS

DM 03.10.00

Usage Laps of trims, gutter, downspouts, Gutter end closure, gutter-downspout connection.

1-6

ZAMIL STEEL BUILDINGS DESIGN MANUAL 2. Standard codes & loads

PEB DIVISION

CHAPTER 2: STANDARD CODES & LOADS 2.1. Standard Codes and Manuals ZAMIL STEEL (PEB) standard codes and manuals used in for calculating applied loads and design of different building’s components are as follows:•

The standard design codes that govern the design procedures and calculations pertaining to builtup sections are as follows: 1) 2)



The standard procedures for the design of cold-formed sections are based on following code: 3)



AISC: American Institute of Steel Construction, Manual of Steel Construction, Allowable Stress Design, Ninth Edition 1989. AWS-D1-1-96: American Welding Society, Structural Welding Code Steel Manual 1996.

AISI: American Iron and Steel Institute, Cold Formed Steel Design Manual, 1986 Edition and 1989 addendum.

For the standard design loads and design practice the design engineer has to refer to the MBMA manual which is exclusively used for low rise metal buildings. 4)

MBMA: Metal Buildings Manufacturers Association, Low Rise Building Systems Manual 1996. The earlier version is of 1986 with 1990 supplement.

The above codes are to be used for the design of buildings by Zamil Steel design engineers unless otherwise specified in the Contract Information Form (C.I.F).

DM 03.10.00

2-1

ZAMIL STEEL BUILDINGS DESIGN MANUAL 2. Standard codes & loads

PEB DIVISION

2.2. Design loads Zamil Steel pre-engineered buildings are designed to take the following types of loads. ZAMIL STEEL Standard design loads is as per MBMA 1996. But the designer must always follow the loads mentioned in the C.I.F. that may require design loads as per building code other than MBMA. 2.2.1. Dead Load This includes the self-weight of rigid frames and imposed dead load due to secondary elements like roof sheeting, purlins, insulation, etc. Following are some standard dead loads (in kN/m2): Purlin + Panel (0.5mm): Purlin + Panel (0.5mm) + Liner (0.5mm) Purlin + Mark Series Roof Purlin + Tempcon Panel

0.10 0.15 0.15 0.15

These loads are pertaining to steel panels. The exact weights of all types of panels & purlins are given in chapter (5) Mezzanine Dead Loads (in kN/m2): Table 2.1. Mezzanine Dead Loads Dead Load Type 75mm Thick Concrete Slab 100mm Thick Concrete Slab 125mm Thick Concrete Slab 150mm Thick Concrete Slab 0.6mm Thick Mezzanine Deck Joists (LL < 5.0 kN/m2) Joists (LL > 5.0 kN/m2) Beams (LL < 5.0 kN/m2) Beams (LL > 5.0 kN/m2) 50mm Screed 25mm Ceramic Tile + 25 Grout Vinyl Tile Carpet 200mm Hollow Block Wall with Plasteron both sides ( per unit wall area ) 200mm Reinforced Block Wall with Plaster(per unit wall area )

Load in kN/m2 1.80 2.40 3.00 3.60 0.06 0.15 0.20 0.15 0.20 1.20 1.20 0.05 0.05 3.50* 5.00*

* Loads should be Verified by customer DM 03.10.00

2-2

ZAMIL STEEL BUILDINGS DESIGN MANUAL 2. Standard codes & loads

PEB DIVISION

2.2.2. Live Loads & Collateral Loads Roof Live Loads The roof live load depends on the tributary area of rigid frames. Refer to table 3.1 and Section 3 of MBMA 1996 for live loads. For built-up frames minimum uniformly distributed live load on roof is 0.57kN/m2 and 1.0 kN/m2 on roof and purlins as per MBMA 1996. However MBMA 1986 allows the use of 0.57kN/m2 as live load for roof and purlins where ground snow load is less than 0.57kN/m2 (*). Roof live loads as per other building codes should be verified before proceeding in your design. Some customers/consultants may require pattern loading in live load applications. Collateral Loads Collateral loads are included in roof live loads that arise due to sprinklers, ducts, lighting fixtures and ceilings. These loads are outlined in Table C2.4.1.2 of Section C2 of MBMA Manual. Following are some of the collateral loads (in kN/m2). Ceiling (Gypsum Board) HVAC Duct Lighting Fixtures Sprinklers

0.15 0.05 0.05 0.15

Mezzanine Live Loads: For Deck Panel: A Live Load of 0.50 kN/m2 has to be considered to account for concreting and curing (in addition to dead load) when designing the mezzanine deck panel. For Floor Live Loads Of Different Occupancy or Use refer to Table 8.1 of Section 8 of MBMA 1996 Manual. Also commonly used occupancies are summarized in table (2.2) :Table 2.2. Commonly Used Occupancies Loads 2

Occupancy Or Use Assembly areas Hospitals Manufacturing

Fixed Movable Operating rooms Wards Light Heavy

Offices Computer Rooms School Classrooms Storage Stores

*

Class rooms first corridors Light Heavy Retail Wholesale

Uniform Load (Kn/m )

Concentrated (Kn)

2.87 4.79 2.87 1.92 5.99 11.97 2.39 4.79 1.92 4.79 5.99 11.97 4.79 5.99

4.45 4.45 8.90 13.34 8.90 8.90 4.45 4.45 4.45 4.45

Low rise building systems manual MBMA1986 – Section C3.1 DM 03.10.00

2-3

ZAMIL STEEL BUILDINGS DESIGN MANUAL 2. Standard codes & loads

PEB DIVISION

Reduction in Mezzanine Live Load: i) MBMA 1996: For A1 > 37.2m2 (400 ft2) and L0 > 4.79kN/m2 (100 psf) reduction in live load is applied as given:

 4.57  L = L 0  0.25 +  A 1   where, L = reduced design live load in kN/m2 L0 = unreduced uniform design live load (kN/m2) of area supported by the member A1 = influence area in m2 which is: - 4x tributary area of a column - 2x tributary area of a beam - panel area for a two-way slab Minimum L: L > 0.5L0 for members supporting one floor > 0.4L0 for members supporting two or more floors. ii)

MBMA 1986: For members supporting more than13.9m2 (150 ft2) and Live Load > 4.79 kN/m2 reduction in live load is calculated as: R = r (10.8A-150) where, R = Reduction in percent r = Rate of reduction equal to 0.08 percent A = Area of floor supported by the member in m2 Maximum R: R < 0.4 for members receiving load from one level only < 0.6 for other members < 23.1 (1+D/L) Where, D = Dead load in kN/m2 for the area supported by the member L = Unit live load in kN/m2 for the area supported by the member.

2.2.3. Roof Snow Load i) MBMA 1996 Snow loads, if any, on roofs are to be applied as per Section 4 of MBMA 1996 which depends on the geographical locations, roof slope and building geometry. The roof snow load pf are determined as: pf = Is C pg where:

DM 03.10.00

pg = ground snow load Is = Importance factor as per Table 4.1.1(a) C = Roof Type Factor 0 for roof slope θ > 70o and as per Table 4.1.1(b) for θ < 70o

2-4

ZAMIL STEEL BUILDINGS DESIGN MANUAL 2. Standard codes & loads

PEB DIVISION

The roof snow load has to be checked for the following situations (if prevailing) Check for: 1) Minimum Roof Snow Loads pf values should be checked with Minimum Roof Snow Loads given as: For slope < 15o: i) When pg < 20 psf ----- Min pf = Is pg ii) When pg > 20 psf ----- Min pf = Is x 20 2) Unbalanced Roof Snow Loads i) Gable Roofs: (but not applicable for Clear Span & mono-slope frames) 2.5o < slope < 15o --- 0.5pf on one slope and pf on the other slope 15o < slope < 70o --- Cu pf on one slope and no load on the other slope Cu as per Table 4.2.1 of MBMA Manual ii) Multi-Gable Roofs: For slopes > 2.5o roof snow loads shall be increased from 0.5pf at the ridge to Cm pf at the valley. The maximum height of snow at the valley need not exceed the elevation of the snow at the lower adjacent ridge. Cm as per Table 4.2.2 of MBMA Manual Height of snow = Snow Load (kN/m2) / D (in kN/m3) D (Density) = 0.435pg + 2.243 < 4.805kN/m3. 3)

Partial Snow Loads

Partial loading has to be checked for multi-span frames and purlins. For Multi-span Framing: Load on Exterior Modules = pf Load on Interior Modules = 0.5 pf For roof purlins: Load on Exterior Bays = pf Load on Interior Bays = 0.5 pf 4) Drifts on Lower Roofs Procedure: Step-1:

Check the need of drift loads

Drift Loads need to be considered if:

DM 03.10.00

2-5

ZAMIL STEEL BUILDINGS DESIGN MANUAL 2. Standard codes & loads

PEB DIVISION

hr −hb > 0.2 hb Where

hb = Height of uniform snow on lower roofs ( pfl / D ) hr = Difference in height between the upper and lower roofs

Step 2:

Calculate drift height

Calculate drift height for both windward (lower) and leeward (upper) cases. Leeward Drift:

h d = 0.43 3 Wb

where:

4

p g + 10 - 1.5 ≤ (h r − h b )

Wb = Roof size along the drift for upper roof > 7.62m (25ft) hb = Height of uniform snow on lower roofs ( pfl / D ) hr = Difference in height between the upper and lower roofs

Windward Drift:

h d = 0.5 x 0.43 3 Wb

where:

Wb =

4

p g + 10 - 1.5 ≤ (h r − h b )

Roof Size along the drift for lower roof

Take the larger hd of above. Step 3:

Calculate Width of Drift Wd:

For hd < (hr – hb ) : Wd = 4 hd For hd > (hr – hb ) :

4h d2 Wd = hr − hb

DM 03.10.00

2-6

ZAMIL STEEL BUILDINGS DESIGN MANUAL 2. Standard codes & loads

PEB DIVISION

Step 4:

Calculate Maximum Intensity pt:

pt = D (hd + hb ) Note: If upper roof slope > 10o extra drift of 0.4hd (sliding drift) has to be considered. However the total drift of 1.4hd shall not exceed (hr –hb ). ii) Snow Load as per MBMA 1986 The roof snow load shall be determined in accordance with the formula: pf = 0.7 pg Roof snow loads in excess of 0.96kN/m2 (20 psf) may be modified when roof angle ‘a’ is greater than 30o according to the formula: pf = 0.7 cs pg

 a - 30  o o cs = 1 −   for 30 < a ≤ 70  40  =0 for a > 70 o where, cs = Slope reduction factor a = Roof angle in degrees Note: Drift load calculations as per MBMA 1986 are similar to as per MBMA 1996. 2.2.4. Wind Load The wind loads are determined in accordance with Section 5 of MBMA 1996. Wind loads are governed by wind speed, roof slope, eave height and open wall conditions of the building. Zamil Steel buildings are not designed for a wind speed less than 110 km/h. Wind design pressure p depends on Importance Factor Iw , velocity pressure q and pressure coefficient GCp as per the following formula: p = Iw q (GCp) where velocity pressure q is evaluated as: q (kN/m2) = 2.456 V2 H2/7 10-5 Where

DM 03.10.00

V = Wind velocity in km/h H = Eave Height (min as 4.57m) = Mean height for roof slope angle > 10o

2-7

ZAMIL STEEL BUILDINGS DESIGN MANUAL 2. Standard codes & loads

PEB DIVISION

GCp values are given for Rigid Frames for transverse and longitudinal directions in Tables 5.4(a) and 5.4(b) of MBMA 1996 Manual respectively. For secondary members GCp values are either evaluated from the formulae given in Tables 5.5(a) through 5.5(f) or directly obtained from the summarized Tables 5.7(a) & 5.7(b). Iw is importance factor taken from table 5.2(a) of MBMA 1996 manual. Open Wall Conditions: GCp values largely depend on the open wall conditions. Buildings are thus defined as Enclosed, Partially Enclosed and Open Buildings. Partially Enclosed Building: A building in which:

1) the total area of openings in a wall that receives positive pressure exceeds 5% of that wall area 2) the total area of openings in a wall that receives positive pressure exceeds the sum of the areas of openings for the balance of the building envelope ( walls and roof ) and

3) the density of the openings in the balance of the building envelope does not exceed 20% This can be expressed as: Ao > 0.05 Ag and and Ao > Aoi

A oi < 0.20 A gi Where: Ao = Total areas of openings in a wall that receives positive external pressure Ag = The gross area of that wall in which Ao is identified Aoi = Total area of openings in building envelope - Ao Agi = Building Envelope Area - Ag Examples of Partially Enclosed Buildings: 1) Building with one side wall or one end wall fully open for access. After applying the above criteria, it is found that this situation satisfies all the criteria mentioned for partially enclosed building and thus, should be treated as partially enclosed building. 2) Building with two opposite walls fully open. This situation may be regarded either as partially enclosed building or open building. If open wall area is 80% of the total wall area then it is regarded as open building. Otherwise it should be treated as partially open building which is the normal case. Open Building: A building in which at least 80% of all walls are open Enclosed Building: A building neither defined as Partially Enclosed building nor as an open building Note: In MBMA1986 ‘Importance Factor’ Iw does not appear in the formula i.e., its value is set to 1.0, while as per MBMA 1996, Iw is read from table 5.2(a) of the manual. 2.2.5. Crane Loads Crane Loads are determined using the crane data available from the crane manufacturer and in accordance with Section 6 of MBMA. Crane data includes wheel load, crab weight, crane weight, wheel-base, end hook approach (used when two cranes operate in one aisle) and minimum vertical and horizontal clearances.

DM 03.10.00

2-8

ZAMIL STEEL BUILDINGS DESIGN MANUAL 2. Standard codes & loads

PEB DIVISION

Wheel Load: Wheel Load (WL) for top running crane: (Assuming 2 end truck wheels at one end of bridge) WL = 0.25BW + 0.5(RC+HT) where, WL = maximum Wheel Load RC = Rated Capacity of the crane HT = weight of Hoist with Trolley BW = Bridge Weight For an under-hung monorail crane, the maximum wheel load may be calculated as: WL = RC + HT Vertical Impact: Top running crane: WL (maximum wheel load) used for the design of crane runway beams, their connections and support brackets shall be increased by 10% for pendant operated bridge cranes and 25% for cab-operated bridge cranes. Vertical impact shall not be required for the design of frames, support columns and foundations. Wheel Load with vertical impact for top running crane: WL = 0.25BW + 0.5(RC+HT) x I where, I = vertical Impact (1.1 or 1.25) Wheel Load with vertical impact for under-hung monorail crane: WL = (RC + HT) x I Underhung Monorail crane: Vertical impact is 25%; maximum wheel load WL = 1.25 x (RC+HT) Lateral Force: Lateral Wheel Load =

0.2x(RC + HT) / 4 = 0.05(RC+HT)

Longitudinal Force per side wall: Longitudinal loads are calculated as 10% of the wheel load. Longitudinal crane bracing is designed to resist this force. For top running crane: Longitudinal Wheel Load = 0.1x2x[0.25BW + 0.5(RC+HT)] = 0.2x[0.25BW + 0.5(RC+HT)] For monorail crane: Longitudinal Wheel Load = 0.1x(RC+HT) A detailed procedure of crane beam analysis has been provided in Section 6.5 of this manual. The crane beam reactions are then used as applied loads on the main frame.

DM 03.10.00

2-9

ZAMIL STEEL BUILDINGS DESIGN MANUAL 2. Standard codes & loads

PEB DIVISION

Allowable Fatigue Stress Range: Use appropriate allowable stress range in the crane beam design program following the steps given below: Step1: Determine the Crane Service Classification using the following table: Table 2.3. CRANE SERVICE CLASSIFICATION Service Classifications

Usage

No. of Lifts per hour

Speed

Service

Repair Shops, Light B

assembly operations, Service and Light

2-5

Low

5-10

Moderate

10-20

High Speed

Light

Warehousing C

Moderate Machine

Moderate

Shops Heavy Machine shops, Foundaries,

D

Fabricating Plants, Steel Warehouses,

Heavy Duty

Container Yards, Mills

Step2: Determine AISC Loading Condition using the following table: Table 2.4. Loading Condition for Parts and Connections Subjected to Fatigue Service Class B C D

AISC Loading Condition R > 0.5 R < 0.5 1 1 2 2 3

where, R = TW/(TW+RC) For Under-hung monorail cranes R = TW/(TW+2RC) for Top Running cranes TW = Total Weight of the crane including bridge + hoist with trolley

Step3: Select the Allowable Stress Range for an appropriate crane-supporting member According the table next page :

DM 03.10.00

2-10

ZAMIL STEEL BUILDINGS DESIGN MANUAL 2. Standard codes & loads

PEB DIVISION

Table 2.5. ALLOWABLE STRESS RANGE (kN/cm2) STRESS CATEGORY LOADING CYCLES

1) B/U Runway Beams 2) B/U Brackets 3) Full penetration Groove Welded Splice on Runway Beams 4) Base Metal @ Welded Transverse Stiffeners 5) Bracket Flange Connection to Frame Columns 6) Bracket Stiffener Connection to the Frame Column 7) Bracket Stiffener Connection to the Frame Rafter for Underhung Cranes 8) Bracket Web Connection to Frame Column 11) A325 Bolts in tension

AISC Loading Condition 1 2 3 Up to Up to Up to 100,000 500,000 2,000,000 33.8 20.0 12.4 33.8 20.0 12.4 24.1 14.5 9.0 24.1

14.5

9.0

15.2

9.0

5.5

15.2

9.0

5.5

15.2

9.0

5.5

10.3

8.3

6.2

16.6

16.6

16.6

2.2.6. Seismic Loads i) MBMA 1996 Seismic forces are evaluated using Equivalent Lateral Force Procedure as outlined in Section 7.4 of MBMA 1996. As per this method seismic base shear V is determined in accordance with the following equation: V = Cs W where, Cs (The Seismic design coefficient) =

2.5C a R

Ca (Seismic Coefficient) as defined in Table 7.4.1.1 (MBMA 1996) R (Response modification factor) as defined in Table 7.3.3 (MBMA 1996) W = Total Dead Load Note: The total dead load includes: 1) In buildings with storage type of live loads, 25% of such live loads to be included in total dead load. 2) The actual partition weight or a minimum weight of 0.5kN/m2 of floor area, whichever is greater must be added. 3) Total operating weight of permanent equipment. 4) Roof snow load has to be included in case it is greater than 1.5kN/m2. Snow load can be reduced by 80% if approved by the local building official. The lateral seismic force Fx induced at any level shall be determined as follows: Fx =

wx h x n

∑wh

V

k i i

i =1

DM 03.10.00

2-11

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

2. Standard codes & loads

Where : wi and wx = The portion of the total gravity load of the building W assigned to level i or x. hi and hx = The height from the base to level i or x. k = An exponent related to the building period. (For Low Rise Buildings k = 1)

The Main frames and P&B frames are designed for lateral seismic forces. Longitudinal bracing shall be designed for an additional seismic force in addition to the wind force. ii) MBMA 1986 Base Shear V: V = 0.14ZKW Where, V = The total lateral seismic force or shear at the base K=1.0 for moment resisting frames Z=0.1875 for Zone I Z=0.375 for Zone II Z=0.75 for Zone III Z=1.00 for Zone IV W = the total dead load including collateral loads and partition loads where applicable. Note: In case live load is of storage type, include 25% of live load in dead load. Also where the snow load is 1.5kN/m2 (31psf) or greater, 25% of the snow load shall be included with the total dead load.

DM 03.10.00

2-12

ZAMIL STEEL BUILDINGS DESIGN MANUAL 2. Standard codes & loads

PEB DIVISION

2.3. Load combinations The Load Combinations as given in Section 9 of MBMA 1996 shall be considered in the design of all buildings unless special combinations are requested in the C.I.F. The following two load combinations are always considered for any building. 1. DL + LL 2. DL + WL Building with Cranes 3. DL + CR 4. DL + CR + 0.5 WL 5. DL + CR + 0.5 LL (applicable as per MBMA 1974 only) Building in Snow Zones 6. DL + SL 7. DL + CR DL + CR + 0.5SL DL + CR + 0.75SL 8. DL + SL + 0.5 WL 9. DL + 0.5 SL + WL

if Pf ≤ 0.62kN/m2 if 0.62 kN/m2 < Pf < 1.48 kN/m2 if Pf ≥ 1.48 kN/m2

Building with Mezzanine Mezzanine Load is added to all previous load combinations where applicable. Building in Seismic Zones 10. [(0.9-0.5Av)*DL] + EL 11. [(1.1+0.5Av)*DL] + [(0.5)*FL] + [( R )*SL] + EL Where Av : Effective Peak Velocity Related Acceleration [ Refer Figure 7.1.4(a) page 1-7-2 of MBMA ‘96] R = 0 for ground snow < 30 psf (1.436 kN/m2) R = 0.2 for ground snow > 30 psf (1.436 kN/m2) Note: For FL>4.79kN/m2 use coefficient of FL as 1.0 DL includes total weight of bridge plus hoist with trolley in the presence of crane For MBMA 1986 the load combinations are: 10. DL+EL 11. DL+SL+EL 11a. DL+EL+CR

12. DL 13. DL 14. DL 15. DL

DM 03.10.00

Buildings in High Temperatures Variation Zone + TL + LL + TL + WL or EL + TL + SL + TL

2-13

ZAMIL STEEL BUILDINGS DESIGN MANUAL 2. Standard codes & loads

PEB DIVISION

where, DL LL WL EL CR SL TL FL

= Dead Load = Live load plus applicable Collateral Load = Wind load = Seismic Load = Crane load plus applicable Collateral Load = Snow load plus applicable Collateral Load = Thermal load = Floor Live Load (Mezzanine Live Load)

Notes : 1. Whenever the building geometry or loading is not symmetric, wind and seismic loads applied left and right both should be considered in their corresponding combinations. 2. When load combination 2 is applied on frames, exclude collateral loads, special roof dead loads (such as roof units), and the mezzanine dead load from `DL'. 3. The allowable stresses for Load Combinations including wind load or seismic load should be increased by 33% as per AISC. 9th Edition, Section A 5.2. of Part 5. 4. Seismic loads should be calculated according to Section 7 of MBMA 1996. 5. Load Combinations 12, 13, 14 and 15 are not stated in the MBMA 1996 Manual. However if the engineer feels that the temperature loads may seriously affect the building, he can check these combinations and if found of little effect, they must be deleted from the calculations and should be used only if required in the CIF. 6. Load combinations including crane or mezzanine are only applicable when the main members supporting the crane or mezzanine are directly connected to the structure. 7. If more than one crane is present, the following loading, where applicable, is to be considered in `CR' (as per Section 6.3 of MBMA 1996 & Table 6.3) as follows:

a) Multiple cranes bumper to bumper in the same frame span (aisle): i) Consider any single crane producing the most unfavorable effect. ii) Consider any two adjacent cranes, with simultaneous vertical wheel loads and 50% of the lateral load from both cranes OR 100% of the lateral load for either one of the cranes whichever is critical.

b) Multiple crane aisles each with single crane: i) Consider single crane in any aisle producing the most unfavorable effect. ii) Consider any two aisles with simultaneous vertical wheel loads and 50% of the lateral load from both cranes or 100% of the lateral load for either one of the cranes whichever is critical. DM 03.10.00

2-14

ZAMIL STEEL BUILDINGS DESIGN MANUAL 2. Standard codes & loads

PEB DIVISION

c) Multiple cranes in multiple aisles:

i) Consider single crane in any aisle producing the most unfavorable effect. ii) Consider any two adjacent cranes in any one aisle, with simultaneous vertical wheel loads and 50% of the lateral load from both cranes or 100% of the lateral load for either one of the cranes whichever is critical. iii) Consider any two adjacent aisles each with one crane, with simultaneous vertical wheel loads and 50% of the lateral load from both cranes or 100% of the lateral load for either one of the cranes whichever is critical. iv) Consider any two adjacent cranes in any aisle, and one crane in any other nonadjacent aisle with simultaneous vertical wheel loads and 50% of the lateral load from three cranes or 100% of the lateral load for any one of the three cranes whichever is critical. 8. Although loading combinations have been stated for Cranes and Mezzanine loads together, Zamil Steel Building Co. strongly recommends that such situations of rigid frame supporting both the crane and mezzanine be avoided whenever possible. (i.e. provide an additional separate support for the mezzanine or crane as the solution). This will eliminate any undesirable vibration in the mezzanine floor due to the operation of the crane. 9. These loading conditions must be specified on calculation sheets. In case customer loadspecifications to be used, the above-mentioned criteria will be overruled.

2.4. Serviceability consideration In addition to strength considerations as stipulated in various building and design codes, due consideration must also be given to deflection and vibration limitations. Standard codes of practice do not impose clear and rigid criteria for limiting the deflection of various structural members leaving it to the professional design engineer’s judgment. Zamil Steel has adopted a conservative policy on defining deflections based upon its extensive building design experience. One good reference available on this subject is “Serviceability Design Considerations for Low-Rise Buildings” published by AISC. The currently adopted deflection limitations by Zamil Steel are illustrated in the tables next page.

DM 03.10.00

2-15

ZAMIL STEEL BUILDINGS DESIGN MANUAL 2. Standard codes & loads

PEB DIVISION

Table 2.6. Serviceability Consideration 1. S t a n d a r d B u i l d i n g Structural Element Main Frame Jack Beams Roof Purlins

Deformation

Vertical

Mezzanine Beam/Joist Main Frame End Wall Columns Wall Girts

Horizontal

Max Limit Span/150 Span/240 Span/150 Span/240 Span/360 E.Height/45 Height/90 Span/90

Loading DL+LL Or DL+SL DL+LL Or DL+SL DL+LL Or DL+SL DL+LL LL DL+WL WL WL

2. B u i l d i n g s W i t h B l o c k w a l l s Structural Element Main Frame Jack Beams Roof Purlins

Deformation

Vertical

Mezzanine Beam/Joist Main Frame End Wall Columns Wall Girts

Horizontal

Max Limit Sapn/150 Span/240 Sapn/150 Span/240 Span/360 E.Height/(45+R*55)(1) Height/90 Sapn/90

Loading DL+LL Or DL+SL DL+LL Or DL+SL DL+LL Or DL+SL DL+LL LL DL+WL WL WL

3. B u i l d i n g s W i t h G l a z e d w a l l s Structural Element Main Frame Jack Beams Roof Purlins

Deformation

Vertical

Mezzanine Beam/Joist Main Frame End Wall Columns Wall Girts

Horizontal

Max Limit sapn/150 Span/240 Sapn/150 Sapn/240 Sapn/360 E.Height/(45+R*205)(2) Height/90 Sapn/90

Loading DL+LL Or DL+SL DL+LL Or DL+SL DL+LL Or DL+SL DL+LL LL DL+WL WL WL

4. B u i l d i n g s W i t h C r a n e s Structural Element Main Frame Jack Beams Roof Purlins

Deformation

Max Limit Span/150 Span/240 Span/150 Span/240 Span/360

Loading DL+LL Or DL+SL DL+LL Or DL+SL DL+LL Or DL+SL DL+LL LL

Vertical

Bay/225

CR

Sapn/500

CR

Span/600 Span/800 Span/1000 E.Height/100 E.Height/240 Height/90 Span/90 Span/400

Crane Class(3) A,B,C Crane Class(3) D Crane Class(3) E,F DL+WL O DL+CR DL+WL O DL+CR WL WL CR

Mezzanine Beam/Joist Relative deflection of adjacent frames at point of support of UHC or MR beam Rigid Frame Rafters supporting UHC or MR beams running laterally in the building Crane Beam Main Frame Carrying Pendant Operated Main Frame Crarrying Cab Operated End Wall Columns Wall Girts Crane Beam

Horizontal

(1)

RW= (block height)/(Eave height) RG= (Glazed height)/(Eave height) (3) Cranes class according to CMAA Note: The maximum eave height to be considered while using this table is 9m. For EH>9m different limitations have to be used. (2)

DM 03.10.00

2-16

ZAMIL STEEL BUILDINGS DESIGN MANUAL 3. Planning PEB

PEB DIVISION

CHAPTER 3: PLANNING PEB Planning of the PEB buildings (low rise metal buildings)(1) and arranging different building components is a very important step for the designer before proceeding with the design of each component. The Following building configurations are significantly affecting the building Stability and Cost:1) 2) 3) 4) 5) 6) 7) 8) 9)

Main Frame configuration (orientation, type, roof slope , eave height) Roof purlins spacing wall girts (connection & spacing) End wall system Expansion joints Bay spacing Bracing systems arrangement Mezzanine floor beams/columns (orientation & spacing) Crane systems

Some of the above configurations may be governed by customer requirements stated in (CIF) but generally the optimal configuration guide lines are outlined in this chapter. For cases when considerable saving in building cost can be achieved by changing some of the input configuration stated in (CIF) without affecting the building end use it should be reported to the sales representative in charge.

3.1. Main Frame Configuration Main frame is the basic supporting component in the PEB systems; main frames provide the vertical support for the whole building plus providing the lateral stability for the building in its direction while lateral stability in the other direction is usually achieved by a bracing system. The width of the building is defined as the out-to-out dimensions of girts/eave struts and these extents define the sidewall steel lines. Eave height is the height measured from bottom of the column base plate to top of the eave strut. Rigid frame members are tapered using built-up sections following the shape of the bending moment diagram. Columns with fixed base are straight. Also the interior columns are always maintained straight.

3.1.1. Main frame orientation Building should be oriented in such a way that the length is greater than the width. This will result in more number of lighter frames rather than less number of heavy frames, this also will reduce the wind bracing forces results in lighter bracing systems.

(1)

The characteristics of the low rise metal buildings are as per section A15 of MBMA 96

DM 03.10.00

3-1

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

3. Planning PEB

3.1.2. Main frame types There are Several types of main frames used in ZAMIL STEEL for PEB buildings, The choice of the type of main frame to be used is dependant on :1) Total width of the building. 2) The permitted spacing between columns in the transversal direction according to customer requirements and the function of the building. 3) The existence of sub structure (RC or masonry ) 4) The architectural requirements of the customer specially the shape of the gable. 5) The type of rain drainage (internal drainage availability). 6) Any customer special requirements. The available types of main frames are clear span, multi span, lean-to, mono-slope, space saver, roof system and multi-gable. Description and usage of each type are as follows 3.1.2.1 Clear Span Clear Span rigid frames are single gable frames and offer full-width clear space inside the building without interior columns. This type of frame is extensively used anywhere an unobstructed working area is desired in diverse applications such as auditoriums, gymnasiums, aircraft hangars, showrooms and recreation facilities. The deepest part of the frame is the knee, the joint between the rafter and the column, which is generally designed as horizontal knee connection. An alternate design of knee joint is as vertical knee connection that is employed for flush side-wall construction. Clear Span rigid frames are appropriate and economical when: i) Frame width is in the range 24m-30m. ii) Headroom at the exterior walls is not critical.

3.1.2.2. Multi - Span When clear space inside the building is not the crucial requirement then Multi-Span rigid frames offer greater economy and theoretically unlimited building size. Buildings wider than around 90m experience a build up of temperature stresses and require temperature load analysis and design. Multi-span rigid frames have straight interior columns, generally hot-rolled tube sections pin connected at the top with the rafter. When lateral sway is critical, the interior columns may be moment connected at the top with the rafter, and in such a situation built-up straight columns are more viable than hot-rolled tube columns.

DM 03.10.00

3-2

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

3. Planning PEB

Multi-Span rigid frame with an interior column located at ridge requires the rafter at ridge to have a horizontal bottom flange in order to accommodate horizontal cap plate. Multi-Span rigid frame is the most economical solution for wider buildings (width > 24m) and is used for buildings such as warehouses, distribution centers and factories. The most economical modular width in multi-span buildings is in the range 18m-24m. The disadvantages of such a framing system include: • • • •

The susceptibility to differential settlement of column supports, locations of the interior columns are difficult to change in future Longer un-braced interior columns especially for wider buildings. Horizontal sway may be critical and governing the design in case of internal columns pined with rafter.

3.1.2.3. Lean- T0 Lean-To is not a self-contained and stable framing system rather an add-on to the existing building with a single slope. This type of frame achieves stability when it is connected to an existing rigid framing. Usually column rafter connection at knee is pinned type, which results in lighter columns. Generally columns and rafters are straight except that rafters are tapered for larger widths (> 12m). For clear widths larger than 18m, tapered columns with moment resisting connections at the knee are more economical. Lean-To framing is typically used for building additions, equipment rooms and storage. For larger widths “Multi-Span-Lean-To” framing can be adopted with exterior column tapered and moment connected at the knee.

DM 03.10.00

3-3

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

3. Planning PEB

3.1.2.4. Mono- slope Mono-Slope or single-slope framing system is an alternative to gable type of frame that may be either Clear Span or multi-span. Mono-Slope configuration results in more expensive framing than the gable type. Mono-Slope framing system is frequently adopted where: i) ii) iii)

Rainwater needs to be drained away from the parking areas or from the adjacent buildings Larger headroom is required at one sidewall A new building is added directly adjacent to an existing building and it is required to avoid: • The creation of a valley condition along the connection of both buildings. • The imposition of additional loads on the columns and foundations of the existing building.

For larger widths “mono-slope-multi-span” framing will be more economical when column free area inside the building is not an essential requirement. 3.1.2.5. Space Saver Space Saver framing system offers straight columns, keeping the rafter bottom flange horizontal for ceiling applications with rigid knee connection. Selection of Space Saver is appropriate when: i) ii) iii) iv)

The frame width is between 6m to 18m and eave height does not exceed 6m. Straight columns are desired. Roof slope of < 0.5:10 are acceptable. Customer requires minimum air volume inside the building especially in cold storage ware houses.

DM 03.10.00

3-4

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

3. Planning PEB

3.1.2.6. Roof System A Roof System framing consists of beam (rafter) resting onto a planned or an existing substructure. The substructure is normally made of concrete or masonry. The rafter is designed in such a way to result in only vertical reaction (no horizontal reaction) by prescribing a roller support condition at one end. The roller supports are provided at one end by means of roller rods. If the roller support condition is not properly achieved in reality and only slotted holes are provided at one end then a horizontal reaction HR has to be considered for the design of supporting system. HR is calculated as: HR = µVR Where, µ = Coefficient of friction between steel and steel VR = Vertical reaction at that end.

A Roof System is generally not economical for spans greater than 12m although it can span as large as 36m. This is due to fact that the Roof System stresses are concentrated at mid-span rather than at the knees.

DM 03.10.00

3-5

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

3. Planning PEB

3.1.2.7. Multi- Gable Multi-Gable buildings are not recommended due to maintenance requirement of valley region, internal drainage and bracing requirement inside the building at columns located at valley. Especially in snow areas, Multi-Gable framing should be discouraged. However for very wide buildings this type of framing offers a viable solution due to: • •

reduced height of ridge and thus the reduced height of interior columns, and temperature effects can be controlled by dividing the frame into separate structural segments

Thus, Multi-Gable buildings are more economical than Multi-Span buildings for very wide buildings. MultiGable frames may be either Clear Spans or Multi-Spans. The columns at the valley location should be designed as rigidly connected to rafters on either side using a vertical type of connection. 3.1.3. Roof Slope A good reduction in rigid frame weight can be achieved by using steeper slopes for Clear Span frames of large widths. Example: Consider Clear Span building of width 42m and eave height of 6m: With slope 0.5:10 ---- Frame Weight = 3682 Kg With slope 1.0:10 ---- Frame Weight = 3466 Kg With slope 1.5:10 ---- Frame Weight = 3328 Kg With slope 2.0:10 ---- Frame Weight = 3240 Kg Higher roof slopes may result in heavy frames in the case of Multi-Span frame buildings due to the longer interior columns. Higher roof slopes help reduce the deflection in wider span buildings. In the areas of high snow higher roof slopes (slopes > 1:10) help reduce the snow loads if snow load governs. Higher roof slope tends to increase the prices of fascias since fascias are designed to cover the ridge. Also increased height of fascias cause the rise in frame weight due to additional wind forces from fascias. However roof slope starts from 2:10 needs sag rods between purlins thus adding to the price of the building.

DM 03.10.00

3-6

ZAMIL STEEL BUILDINGS DESIGN MANUAL 3. Planning PEB

PEB DIVISION

Optimum roof slopes: • Multi-Span Buildings: • Clear Span, Width up to 45m: • Clear Span, Width up to 60m: • Clear Span, Width > 60m:

0.5:10 1.0:10 1.5:10 2.0:10

3.1.4. Eave Height Eave height is governed by: • Clear height at eave (head clearance) • Mezzanine clear heights below beam and above joist • Crane beam / Crane hook heights Minimize eave height to the bare minimum requirement since the eave height affects the price of the building by adding to the price of sheeting, girts and columns. If columns are unbraced eave height affects the frame weight significantly. Also higher eave heights increase the wind loads on the building. If eave height to width ratio becomes more than 0.8 then the frame may have a fixed based design in order to control the lateral deflection. 3.2. Roof Purlins Roof purlins are to be arranged according to the following guide lines as applicable:1. 900 mm between first roof purlin and the eave strut 2. Intermediate spacing in case of single skin panels not exceeding 1750 mm(*). 3. Intermediate spacing in case of Tempcon panels not exceeding 2000 mm(*). 4. Equal intermediate roof purlin spacing are preferred satisfying the following conditions :• The minimum distance between any purlin line and end wall column position is 150 mm. • The minimum distance between any purlin line and main frames splices is 150 mm. 5. If Zamil Steel Standard skylights(1) are required the lighter weight solution of the following is to be used :• Provide an extra run of purlins at the skylight location. • Provide standard 1.5m spacing over the span where skylights exist and use wider spacing at other spans. 3.3. Wall Girts Our standard practice is to have: • Endwall girts as flush with end wall columns (columns spacing is around 5m-6m), which provides a diaphragm action in the P&B endwalls and avoids the need of endwall bracing. • Side wall girts as by-framed (by-pass) that allows lapping of the girts and larger main frames columns spacing can be used. If there are no customer special requirements (special wall openings, block walls, etc.) wall girt spacing are as follows:2250mm(*) form finish floor level (to allow for recent or future erection of ZAMIL STEEL standard personal doors), then girt spacing not exceeding 2000mm(∗)

(1) (∗)

Zamil Standard skylight can only fit to 1.5m purlin spacing, available length of 3.25m can span over 2 purlins. Panel strength must be checked for any used spacing

DM 03.10.00

3-7

ZAMIL STEEL BUILDINGS DESIGN MANUAL 3. Planning PEB

PEB DIVISION

3.4. End Wall Systems The standard end wall are designed as post & beam (all connections are pinned) the lateral stability is provided by the diaphragm action (see clause 6.4.) in the absence of this shear diaphragm wind bracing are required (see clause 7.2.1.2. of this manual). End rigid frame are used in case of:1) Future extension is intended or if stated clearly in the (C.I.F.), in this case only wind posts are required. 2) Crane running to the endwall 3) Open for access condition prevails at the endwall 4) X-bracing is not allowed at endwall in the case of by-framed end wall.

3.5. Expansion Joints The maximum length of the building without any expansion joint can be calculated using following formula.

L=

Where ∆max L E ∆T K

Example:

∆ max KE∆ T

= Maximum Allowable Expansion in cm. = Length of building in cm. = Coefficient of linear expansion (0.0000117/ oC) = Temp. Difference in oC = 1.0 for building w/o air-conditioning = 0.7 for building w / air-conditioning = 0.55 for building w / heating and air-conditioning

Calculate the maximum length when expansion joint is required for the following locations: Dhahran, Jeddah and Riyadh Consider 2.8-cm expansion slot, which is derived from purlin expansion joint detail

Note: 2mm expansion per purlin connection, assuming 14 bays gives: 14 x 2 = 2.8cm Solution: Temperature difference in Saudi Arabia: Dhahran - 35 oC ) Based on "Engineer's Guide to Solar Energy" By Yvonne Howell & Justin A. Bereny - page 175 Jeddah - 30 oC ) Riyadh - 40 oC ) I

Dhahran Area 1)

Building without air-conditioning (K = 1.0)

L= 2)

Building with air-conditioning (K = 0.70) L=

DM 03.10.00

2 .8 = 6837cm ≈ 68m 1x 35x 0.0000117 6837 = 9767 cm ≈97m 0.70 3-8

ZAMIL STEEL BUILDINGS DESIGN MANUAL 3. Planning PEB

PEB DIVISION

3)

Building with heating and air-conditioning (K = 0.55) L=

II

6837 = 12431 cm ≈ 124m 0.55

Jeddah Area 1)

Building without air-conditioning L=

2)

Building with air-conditioning L=

3)

7977 = 11396 cm ≈ 113m 0.70

.

Building with heating and air-conditioning L=

III

2 .8 = 7977cm ≈ 79m 1x 30 x 0.0000117

7977 = 14504 cm ≈ 145m 0.55

Riyadh Area 1)

Building without air-conditioning L=

2)

Building with air-conditioning L=

3)

2 .8 = 5983 cm ≈ 59 m 1x 40 x 0.0000117 5983 = 8547 cm ≈ 85m 0.70

Building with heating and air-conditioning L=

5983 = 10878 cm ≈ 108m. 0.55

3.6. Bay Spacing For standard loads the most economical bay spacing is around 8m. The standard loads are: Live Loads on roof and frame (kN/m2) 0.57

Wind Speed (km/h) 130

For greater loads than standard loads the economical bay spacing tends to decrease. For buildings with heavy cranes (crane capacity > 10 MT) the economical bay spacing ranges between 6m and 7m. Smaller end bays than interior bays will taper off the effect of higher deflection and bending moment in end bays as compared to interior bays and help reduce the weights of purlins/girts in the end bays. This will avoid the need of nested purlins/girts in the end bays and result in uniform size of purlin/girt sizes. DM 03.10.00

3-9

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

3. Planning PEB

Some buildings require bay spacing more than 10m in order to have a greater clear space at the interior of the building in Multi-Span buildings. Such a situation can be handled by providing jack beams (see clause 4.2.) that support the intermediate frames without interior columns. Thus the exterior columns will have bay spacing of say 6m while the interior columns are spaced at 12m. Intermediate frames allow the purlin to span for 6m as shown in the Figure next page

Estimation of economical bay spacing: Example No. 1 Building Length = 70m No. of Interior bays = (70-12)/8 = 7.25 Use 7 @ 8m Size of End bays = (70-8x7)/2 = 7m Bay Spacing: 1 @ 7 + 7 @ 8 + 1 @ 7 Example No. 2 Building Length = 130m --- Needs an expansion joint No. of Interior bays = (130-24)/8 = 13.25 Use 14 @ 7.5m Size of End bays = (130-14x7.5)/4 = 6.25m Bay Spacing: 1 @ 6.25 + 7 @ 7.5 + 1 @ 6.25 + Exp. Jt + 1@ 6.25 + 7 @ 7.5 + 1 @ 6.25

DM 03.10.00

3-10

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

3. Planning PEB

3.7. Bracing Systems Arrangement Bracing is a structural system used to provide stability in a structure in a direction where applied forces on that structure would otherwise make it unstable. Whether it is a force due to wind, crane or seismic applications, the bracing system will always eventually transmit that load down to the column base and then to the foundations. The rules of arranging different types of bracing systems are as follows:-

3.7.1. Bracing for wind and seismic loads in the longitudinal direction 1. In long buildings, braced bays shall be provided in intervals not to exceed five bays. 2. Although there is a diaphragm action available in Zamil Steel Buildings roof, this action is not as of yet quantitatively determined. Therefore, the Design Engineer shall not take diaphragm action into consideration, until a future revision to this rule is made. 3. A braced bay shall not be located in the end bay of a building if the endwall system at the end is a post and beam frame. If an exception to this is necessary, the design engineer must design the endwall members as either built-up or hot-rolled sections. 4. Sidewall bracing shall be generally placed in the same bays of roof bracing. This may not be possible at times due to openings in the sidewalls. In such cases, sidewall bracing shall be placed in bays adjacent to those containing the roof bracing with a consideration that load transfers to the adjacent bays. 5. Roof rod bracing shall not cross the ridgeline. 6. Cables / rods braces shall not exceed 15m in length. If a cross bracing contains rods longer than 15m, then the bracing should be broken to two sets of bracings with a strut member between them so that the rod/cable lengths shall not exceed 15 m. 7. Roof bracing shall be comprised of ASTM A 475 Class A extra high strength cables or ASTM A 572 Grade 36 rods or ASTM 572 Grade 50 angles. 8. Sidewall bracing shall be comprised of any one of the following types: • Cables • Rods or angles. • Portal frame with / without rods or angles. 9. There shall be only one type of bracing in the same sidewall. Do not mix different type / material in the same sidewall. 10. It is preferable to use only one type of wall bracing in the whole building otherwise the lateral loads (especially seismic loads) will not be divided equally between bracing lines, For cases when this will result in excessive weight for bracing system advanced calculation (rather than those described in clause 7.2.1.1.) is to be done to determine the force that will be carried by each type depending on its stiffness and location. DM 03.10.00

3-11

ZAMIL STEEL BUILDINGS DESIGN MANUAL 3. Planning PEB

PEB DIVISION

3.7.2. Wind and seismic bracing in P&B endwalls 1. Endwall bracing is not required for a fully sheeted P&B endwall with flush girt construction. If P&B endwalls have by-framed girts then this endwall needs bracing. 2. If required, bracing in P&B endwalls shall comprise cables or rods, unless otherwise specified by the customer. In such a case the endwall members shall be either built-up or hot-rolled members. 3. If an endwall requires bracing and the customer requests that no bracing to be placed in the plane of the endwall, then it is recommended that the load in the plane of the endwall is transferred back to the first rigid frame through additional roof bracing in the end bay. 4. In wide buildings, if endwall bracing is required, it shall be provided in intervals not to exceed five endwall sections.

3.7.3. Crane Bracing 1. In crane buildings, bracing has to be designed for longitudinal crane loads for top running or underhung cranes. The bracing shall be placed in intervals not to exceed five bays. 2. Longitudinal bracing for top running cranes shall be comprised of any one of the following types. • Rods (for cranes with a capacity of 15 tons or less) •

Angles (for cranes with capacity exceeding 15 tons)



Portal frame with rods (or angles)



Portal frame without rods (or angles)

3. Longitudinal bracing for top running cranes shall be of only one type in the same longitudinal plane of a building. 4. Longitudinal bracing for underhung cranes shall consist of either rods or angles. 5. Lateral bracing for underhung cranes (attached to crane brackets), if any shall consist of either rods or angles. 6. Whenever a brace rod is used for crane bracing, the minimum diameter of that rod shall be 19mm. 7. A brace rod shall not exceed 15m in length. If angle are used the critical slenderness ratio of a bracing angle shall not exceed 300.

DM 03.10.00

3-12

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

3. Planning PEB

3.8. Mezzanine Floors The following guide lines are to be considered while planning mezzanine floor:1. Most economical mezzanine column spacing is around 6m. Mezzanine columns should be aligned with rigid frame column and wind column grid lines. 2. Generally aligning joists with the shorter panel side results in lighter weight for mezzanine floor. 3. Clear height above mezzanine joist and below mezzanine beam must be maintained preferably between 2.5m-3.0m and not to be less than 2m. 4. Top landing requirements in mezzanine staircases is governed by the relative orientation of the staircase to the building orientation as shown in the following Figure. 5. Maximum number of rises in a single straight flight without mid-landing is 15. If the number of rises exceeds 15 then mid-landing must be provided. Remember the rise varies between 160mm to 200mm but preferably a rise of 175mm is commonly used.

6. The choice of single or double flight should be based on the mezzanine layout, available space and customer’s requirements.

DM 03.10.00

3-13

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

3. Planning PEB

3.9. Cranes Systems The following guide lines are to be considered while choosing the crane structural system:1. Avoid top running cranes running in the transverse directions since it requires extra supporting system. 2. Top running cranes are the most economical option as compared to underhung cranes. 3. Use bracket as Crane runway beam support when vertical loads < 250kN. Otherwise use a separate crane column or a stepped column. Stepped columns are more economical than separate crane column especially for larger eave height buildings. 4. Underhung cranes are employed in case where the crane span is smaller than the building aisle width. 5. Underhung crane capacity should be limited to 10MT and under-hung monorail crane capacity should not exceed 5MT for a reasonably economical design of frame.

DM 03.10.00

3-14

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

CHAPTER 4: MAIN FRAMING DESIGN 4.1. Main Frame Design Procedure and Constraints Main frame method of design, the choice of haunch depths, haunch lengths and splice location has a significant effect on the economy of the building as a whole. In house special software (ASFAD) is used for the design procedure. 4.1.1. ASFAD Design and analysis of rigid frames is carried out using an in-house developed software ASFAD. This package was developed to satisfy the requirements of the Pre-Engineered Steel Buildings industry using C++ language utilizing the latest programming, analysis and design techniques. It has many features to facilitate design of various elements and to ensure the economy, safety, uniformity and high quality of the structural designs. Refer to the computer aids manual for detail information and user guidelines on this software. However some features are outlined here. Structural modeling is based on dividing the Structure into Members, which connect to each other at common points called Nodes. Following are few examples of node numbering:

The method used for the analysis of a Structure is the Stiffness Matrix Method. DM 03.10.00

4-1

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

Members may have variable properties along their lengths. Such Members are called non-prismatic elements and the stiffness coefficients for such Members are calculated by numerical integration techniques. End forces at nodes due to intermediate member loading are also calculated by the same numerical integration techniques. The numerical integration technique is based on the Energy Method which is achieved by dividing a Member into Segments (Members are broken into Sections and Section are broken into Segments). The accuracy of this method depends on the length of Segment and number of Segments in the Member. Analysis results for different models have proven that the use of a 0.5 meter segment and a minimum of 10 segments per member lead to very accurate and acceptable results. Loading is defined by specifying various Load Cases, Load Categories & Load Conditions. Example: The Load Condition “Dead + Wind + Crane” Load Categories in a Load Condition

Dead

Load Cases within Category

Dead

All Possible Load Case Combinations

+

Wind

Crane

+

Wind right Wind left Wind end

Crane-1 Crane-2 Crane-3 Crane-4

Dead Dead Dead Dead

+ + + +

Wind right Wind right Wind right Wind right

+ + + +

Crane-1 Crane-2 Crane-3 Crane-4

Dead Dead Dead Dead

+ + + +

Wind left Wind left Wind left Wind left

+ + + +

Crane-1 Crane-2 Crane-3 Crane-4

Dead Dead Dead Dead

+ + + +

Wind end Wind end Wind end Wind end

+ + + +

Crane-1 Crane-2 Crane-3 Crane-4

As shown in the above example categorizing Load Cases makes one Load Condition sufficient to specify all possible 12 Load Case combinations rather than specifying each of them individually.

DM 03.10.00

4-2

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

4. Main framing design

Design Codes for checking of stresses using ASFAD are:AISC Ninth edition 1989 BS 5950 Part 1: 1990 BS 5950 Part 1: 2000 Egyptian code ECP97 Egyptian code ECP2001 Eurocode 3 All the Sections within a Member are checked segment by segment and the most critical point within the section is reported for bending & axial stresses, shear stresses & deflections. Since Members are non-prismatic elements the critical buckling Load is determined for the whole member using numerical integration techniques. This will simulate the actual buckling behavior of the non-prismatic member accurately rather than analyzing the Member at each segment individually that does not take into effect the interaction of all segments when they behave as one member. Auto design of built up Section dimensions (widths and thicknesses) are available for some codes but in general user defined dimensions are checked for stresses according to specified code, some limitations must be taken into consideration while choosing the dimensions of the built up section to be checked as indicated below. 4.1.2. Design Constraints 4.1.2.1. Built up section Geometrical limitation were established to achieve the following targets 1. Ease shop fabrication 2. Limit the reduction of allowable stresses due to high (width / thickness) ratios resulting in non economical designs. 3. To ensure sound designs and optimize material cutting and minimize material waste Table 4.1 illustrates the used web plates and flange plates used and the accepted combination between them to form a built up sections, this table is called plate 7

DM 03.10.00

4-3

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

Table 4.1 Built Up Geometry Limitation PLATE 7 Web Depth (mm)

200

Min Web Thick. (mm)

300

400

500 4

600

700

800

900 5

1000 6

1100

1200

1300

1400

1500

8

1600

1700

1800

10

Flange size 125X5 125X6 125X8 150X5 150X6 150X8 150X10 175X6 175X8 175X10 175X12 200X6 200X8 200X10 200X12 225X8 225X10 225X12 225X15 250X8 250X10 250X12 250X15 300X10 300X12 300X15 300X20 350X12 350X15 350X20 350X25

NOTES: • Hatched areas are not to be used. • Upon manual design designer must consider provision of clause G2 of AISC 9th Edition. Page 5-51. • Upon special depths, the following limitations have to be checked. hw t w ≤ 180

t f t w ≤ 2 .5 hw w f ≤ 5



where hw = web depth, tw = web thickness, tf = flange thickness and wf = flange width. The above dimensions are not applicable for galvanized members

DM 03.10.00

4-4

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

4.1.2.2. Galvanized primary members The following limitation should be considered The maximum dimensions of built up or hot rolled piece are 830x750x9500mm (including any welded parts like gusset plates, bracket) The maximum weight of any one piece 1050kg * For special cases where larger dimensions/weights can not be avoided out side galvanized must be sought, extra charges should be accounted be estimate department. Built up cross sections to be conformed Table 4.2 Galvanized Built Up Geometry Limitation PLATE 8 Web Depth (mm) Min Web Thick. (mm)

200

300

400 5

500

600 6

700

800 8

900 10

1000

1100

1200

12

1300

1400

1500

15

1600

1700

1800

20

Flange size 125X5 125X6 125X8 150X6 150X8 150X10 175X8 175X10 175X12 200X8 200X10 200X12 225X10 225X12 225X15 250X10 250X12 250X15 300X12 300X15 300X20 350X15 350X20 350X25

NOTES: • • •

Hatched areas are not to be used. For regular design refer to limitations of PLATE 7. Upon special depths, the following limitations have to be checked. hw t w ≤ 100 w f 2t f ≤ 13 w f t f ≥ 0.25hwt w

where hw = web depth, tw = web thickness, tf = flange thickness and wf = flange width

DM 03.10.00

4-5

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

4.1.2.3. Fabrication Limitation Conrac is an automatic welding machine, which welds the web to the top and bottom flanges with single side fillet welding with one head fixed at one flange (straight) and the other head movable in order to fabricate tapered built-up sections. Following are the size limitations of built-up members welded by this machine. Size Limitations: 1)

Minimum web thickness = 3mm;

Maximum web thickness = 12mm

2)

Minimum flange thickness = 5mm; Maximum flange thickness = 25mm

3)

Minimum web depth = 180mm;

Maximum web depth = 1500mm

4)

Minimum flange width = 125mm;

Maximum flange width = 380mm

5)

Minimum member length = 1500mm;

6)

Minimum Fillet Weld Size = 3mm; Maximum Fillet Weld Size = 8mm Fillet weld size depends upon the material thickness (see clause 4.7.1.)

7)

If the sizes are out of the above ranges manual welding has to be undertaken.

8)

Width of continuous Flange should be constant along the one welded piece. Also top and bottom flange widths must be same.

9)

Variation of thickness at any butt weld splice of continuous Flange / Web within the one welded

Maximum member length = 16000mm

piece should be limited to maximum 6mm. 10)

Maximum thickness of a flange that can be bent is 19mm

11)

One of the flanges (normally top) of the built-up member must be straight.

12)

Butt web splices must be perpendicular to the straight flange.

13)

Maximum bend angle for the flange is 28.44o (normally top flange bends at peak while bottom flange is straight in multi-span building frames)

14)

In relation to the straight flange the maximum slope that welding head can follow at the other flange is 15o.

The previous rules should be respected in the design of built up section to be fabricated using conrac machine those rules are illustrated in the sketch next page:-

DM 03.10.00

4-6

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

(BUS) CONRAC FABRICTION LIMITATION L1 Feild Splice Plate

Feild Splice Plate

H W1

H W1

HW2

TF1

TF2

STRAIGHT FLANGE

H W2

TF3

TF4

TF4

MAX 28.44

FLANGE BENT

MAX 15

WEB BUTT WELD

BTF2

TW2

TF4

H W1

S(mm)

HW2

TF2

TF1

BTF1

TW1

BBF2

SEC. 2-2

1.

3mm ≤ (Tw1 , Tw2) ≤ 12mm

2.

5mm ≤ (TF1 , TF2 , TF3 ,TF4 ) ≤ 25mm

3.

180mm ≤ (HW1 , HW2) ≤ 1500mm

4.

125mm ≤ (BTF1 , BBF1 BTF2 , BBF2 ) ≤ 380mm

5.

1500mm ≤ L1 ≤ 16000mm

6.

3mm ≤ S ≤ 8mm

7.

BTF1 = BBF1 = BTF2 = BBF2

8.

│TF2 - TF1│ ≤ 6mm ,

│TF3 - TF4│ ≤ 6mm

& │ Tw1 - Tw2 │≤ 6mm 9.

TF3

BBF1

TF4 ≤ 19mm

SEC. 1-1

4.1.2.4. Shipping Limitation Maximum fabricated out-to-out length of the piece is 12m for transportation by truck and 11.7m for transportation by dry cargo container. 4.1.2.5. Shot Blast and Paint Line Limitations •

Maximum built-up member length

= 15,000mm



Maximum built-up member width

= 392mm (for paint line); 800mm (for shot blasting)



Maximum built-up member depth

= 1500mm



Maximum built-up member weight

= 2MT

DM 03.10.00

4-7

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

4.1.2.6. Other guidelines 1. At Knee connection column depth and rafter depth should be the same as applicable if not the difference to be limited at ± 200mm. 2. For main column at Crane Bracket zone , preferably the depth of that column to be constant starting at a minimum distance of 150 mm below the bracket, and extending all the way up to the top of the column.

3. In a tapered section, the minimum difference in web depths at start and end should be 100 mm. •

Minimum base plate thickness

=

12 mm



Minimum base plate width

=

220 mm



Minimum splice plate thickness

=

10 mm



Minimum splice plate width

=

200 mm



Minimum Anchor bolt diameter

=

20 mm (except end-wall post = 16mm)



Minimum splice bolt

=

16 mm

DM 03.10.00

4-8

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

4.1.2.7. Optimization The following rules should be followed to produce the most economical frame profiles. These rules result in lighter frames while satisfying fabrication, shipping and erection limitations. 1. Minimize number of splices in the columns and rafters by providing maximum possible lengths regardless of the material savings that can be produced otherwise. Section lengths should be multiple of 3m i.e., 3m, 6m, 9m and 12m in order to reduce the scrap. 2. In case of different bay spacing avoid using more than 3 frames. 3. Different frame should be adopted if saving of 5% on all frames with a minimum of 1.0ton is ascertained. 4. When different frames have to be used due to different bay spacing, maintain the same web cuts for all such frames. 5. Minimize the number of different flange widths in a frame. Maximum different widths of flanges in all the frames should preferably be less than three. 6. As much as possible maintain uniformity in the base plate detail and anchor bolt sizes for all the frames. 7. Try to locate the splices at the locations where the bending moment is least and/or where the depth is least in a frame. 8. Try to follow the shape of bending moment diagram for the controlling load combination in the configuration of the frame by maintaining the stress unity check ratios closer to 1. Controlling Deflections: Lateral Sway ∆h: If lateral sway ∆h exceeds the prescribed limit (normally EH/45) then check the EH/Width ratio. If H/B > 0.75 then fixing the base would result in more economical frame. If H/B 1.0 increase web thickness. Slenderness Ratio Check: The slenderness ratio (KLu)/r of a member under compression must be less than 200. Usually in the minor axis this ratio may exceed the limit. Increasing the flange width in comparison to web depth would improve the slenderness ratio. K = Effective length factor Lu = Unbraced Length r = Radius of gyration (√I/A) Note: While optimizing keep in mind to satisfy clauses from 4.1.2.1 to 4.1.2.6

(1) (2)

Refer for clause 4.3.1. for flange brace requirements Refer to clause 7.2.3.1. for connection details

DM 03.10.00

4-10

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

4. Main framing design

4.2. Design of Jack Beams A Jack Beam is employed to support another beam or rafter, thus eliminating a column support at that location. Jack beams are commonly used in multi-span buildings where the client may need additional clear space for equipment or for material handling purpose. Jack beams may also be required in sidewalls where an oversized framed opening (i.e. larger than the bay spacing) is required, thus eliminating a sidewall column. 4.2.1. Loads Jack beams are designed to support dead plus live loads (i.e. gravity loads), and dead plus wind uplift loads in their major axis. When sidewall jack beams are required, they are generally not designed to withstand any lateral or horizontal wind loads in their minor axis. To eliminate this minor axis bending in the jack beam, the intermediate rigid frame rafter resting on the jack beam should always be braced in the roof back to the adjacent main rigid frames. Therefore the horizontal load from the wind transmitted to the rafter is then distributed through the bracing to the adjacent main rigid frames. These adjacent rigid frames should be designed for additional vertical and horizontal loads from the jack beam. Refer to sketch below showing bracing arrangement:

DM 03.10.00

4-11

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

4.2.2. Connection details Typical details showing the connection of jack beam to the main rigid frame and supporting arrangement are shown below:

4.2.3. Design parameters Parameters for Allowable Stresses: Lx Ly

= full length of beam = Lb (maximum length from either support to rafter being supported)

For deign using AISC (ASD 1989) = 1.75 - for a single point load • Cb = 1.0 - for 2 or more point loads • Allowable stresses are calculated in accordance with the AISC Specifications as documented in Section 5. • For the DL + WL (uplift) conditions, the allowable stresses are increased by 33%.

DM 03.10.00

4-12

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

4. Main framing design

4.2.4. Design Procedure 1) Design the main rigid frame without jack beam loads. 2) Modify the input of main rigid frame to model the intermediate rigid frame in the detail mode of ASFAD. 3) Design the jack beam, using the reactions from intermediate rigid frame for a maximum vertical deflection of span/240. Use ASFAD-Detail Mode Input Level to design the jack beam. 4) Redesign intermediate frame in step 2 by applying the actual deflection of jack beam as support settlement. Other alternative to this approach is to estimate the stiffness of the elastic support provided by the jack beam and provide an elastic support condition with the calculated stiffness. Stiffness k = Total Load /(deflection under that load). 5) Redesign the main rigid frame in step 1 for the additional vertical and/or horizontal loads from jack beam (reactions of jack beam) Miscellaneous Notes: 1) The connection from the jack beam to the rafter being supported shall always be designed as a pinned connection. 2) Bearing stiffeners shall always be supplied on the rafter being supported at the jack beam location. 3) If larger clear height inside the building is desired, the jack beam can be located in the rafter line as shown in sketch below.

DM 03.10.00

4-13

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

Example: Design the jack beam as shown below:

Dead Load Live Load Wind Load Bay Spacing

= 0.15 kN/m² = 1.0 kN/m² = 1.2 kN/m² = 6.0mm

Step 1: The frame shown above is designed as multi-span of 2 modules for the given loading. The ASFAD input of the main rigid frame in MACRO MODE is shown below. *HEADER TITLE:MAIN FRAME: MULTI-SPAN(2@18) MBMA'86 1.00LL/130KPH WIND 7M EH/6M BAY INIT:MSA *SPANS 18.00

18.00

*MEMBERS 200.00 S=000.00 H=007.00 F=NT C=2 500.00 130x06 4 130x06 0.00 B 2.25D 3.80D 5.3D 500.00 S=00.5 500.00 130x06 600.00 130x06 750.00 180x08 P 0.90 1.50

E=000.00 C=2-4 4 130x06 0.00 4 130x06 6.00 5 180x10 3.00 0.60 B=T.T.T.T.T..TTT................

300.00 F=NN C=2 300.00 180x06 4 180x08 B SYM *LOADS DEAD LIVE WIND BAY

0.00

0.15 1.00 1.2 Q 6.00

*END

DM 03.10.00

4-14

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

Step 2: The input shown in step 1 is modified in DETAIL MODE of ASFAD for a frame without an interior column and instead with a support at that location as shown below. Node no. 4 has been reduced as dummy node by fixing that node and prescribing the support condition for node 3. From the member list member 4-3 has been removed. *HEADER TITLE:INTER-FRAME: MULTI-SPAN(2@18) MBMA'86 1.00LL/130KPH WIND 7M EH/6M BAY INIT:MSA *NODES 1 2 3 4 5 6

0.306 0.456 18.000 18.000 35.544 35.694

0.000 6.566 7.315 0.000 6.566 0.000

*SUPPORTS 1 X Y 3 Y 4 X Y M 6 X Y *MEMBERS 1 2 0.00 0.24 NNN NNN 200.0 500.0 130.0x06.0 4.0 130.0x06.0 B 2.25D 3.80D 5.30D

0.00

2 3 0.24 0.00 NNN NNN 500.0 500.0 130.0x06.0 4.0 500.0 600.0 130.0x06.0 4.0 600.0 750.0 180.0x08.0 5.0 B 0.47T 1.97D 3.47T B 12.48T 13.98D 15.49D

130.0x06.0 0.00 130.0x06.0 6.00 180.0x10.0 3.00 4.97D 6.47T 7.98D 16.99T

3 5 0.00 0.24 NNN NNN 750.0 600.0 180.0x08.0 5.0 600.0 500.0 130.0x06.0 4.0 500.0 500.0 130.0x06.0 4.0 B 0.57T 2.07D 3.58D B 12.59D 14.09T 15.59D

180.0x10.0 3.00 130.0x06.0 6.00 130.0x06.0 0.00 5.08T 6.58D 8.08T 17.09T

6 5 0.00 0.24 NNN NNN 200.0 500.0 130.0x06.0 4.0 130.0x06.0 B 2.25D 3.80D 5.30D *LOADS 1 G ALL 2 3 2 5 2 3 2 5 1 1 1 DM 03.10.00

2 DEAD

GWY

-1.00

3 5 3 3 3 5 3 3 2 2 2

GUY GUY GCY GCY GUY GUY GCY GCY GUX GUX GUX

-0.90 -0.90 -0.41 -0.41 -5.99 -5.99 -2.74 -2.74 1.80 -3.96 -5.04

DEAD DEAD DEAD DEAD LIVE LIVE LIVE LIVE WINDLEFT WINDRIGHT WINDEND

9.48T

10.98D

9.58D

11.08T

0.00

4-15

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

2 2 2 2 2 2 2 2 2 3 3 3 6 6 6 5 5 5 5 5 5 STATIC

1 WINDLEFT 1 WINDRIGHT 1 WINDEND 3 WINDLEFT 3 WINDRIGHT 3 WINDEND 3 WINDLEFT 3 WINDRIGHT 3 WINDEND 5 WINDLEFT 5 WINDRIGHT 5 WINDEND 5 WINDLEFT 5 WINDRIGHT 5 WINDEND 6 WINDLEFT 6 WINDRIGHT 6 WINDEND 3 WINDLEFT 3 WINDRIGHT 3 WINDEND DEAD

GCX GCX GCX LCY LCY LCY LUY LUY LUY LUY LUY LUY GUX GUX GUX GCX GCX GCX LCY LCY LCY

0.78 -1.72 -2.19 3.29 2.14 3.29 7.20 4.68 7.20 4.68 7.20 7.20 3.96 -1.80 5.04 1.72 -0.78 2.19 -2.14 -3.29 -3.29

*LOADCOND 1.00 1.00 DEAD 1.00 LIVE 0.75 1.00 DEAD 1.00 WIND *DESIGN 1 2 KX=1.5 OFF-KX=0.0 6 5 KX=1.5 OFF-KX=0.0 *CONNECTIONS RT 1 2 3 ID 2 3 1 ED 2 3 3 SD 3 5 1 ID 3 5 2 LT 6 5 3 P 1 2 P 6 5 *END

Step 3: The reactions of intermediate frame of step 2 are obtained from the output as shown below: Structure Reactions and Displacements - Load Case no. 1...DEAD

Node No. ---1 2 3 4 5 6

Vertical Horizontal Moment Vertical Horizontal Rotation Reaction Reaction Reaction Displac. Displac. Angle (kN) (kN) (kN.m) (cm) (cm) (deg) ---------- ---------- ---------- ---------- ---------- ---------10.460 2.292 0.000 0.000 0.000 0.074 0.000 0.000 0.000 -0.011 0.006 -0.091 25.742 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 -0.011 -0.005 0.091 10.460 -2.292 0.000 0.000 0.000 -0.074

DM 03.10.00

4-16

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

4. Main framing design

Structure Reactions and Displacements - Load Case no. 2...LIVE

Node No. ---1 2 3 4 5 6

Vertical Horizontal Moment Vertical Horizontal Rotation Reaction Reaction Reaction Displac. Displac. Angle (kN) (kN) (kN.m) (cm) (cm) (deg) ---------- ---------- ---------- ---------- ---------- ---------44.692 11.179 0.000 0.000 0.000 0.364 0.000 0.000 0.000 -0.051 0.027 -0.450 126.464 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 -0.051 -0.026 0.450 44.692 -11.179 0.000 0.000 0.000 -0.364

Structure Reactions and Displacements - Load Case no. 3...WINDEND

Node No. ---1 2 3 4 5 6

Vertical Horizontal Moment Vertical Horizontal Rotation Reaction Reaction Reaction Displac. Displac. Angle (kN) (kN) (kN.m) (cm) (cm) (deg) ---------- ---------- ---------- ---------- ---------- ----------56.257 0.599 0.000 0.000 0.000 -0.164 0.000 0.000 0.000 0.065 -0.086 0.415 -146.693 0.000 0.000 0.000 -0.000 -0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.065 0.085 -0.415 -56.257 -0.599 0.000 0.000 0.000 0.164

Structure Reactions and Displacements - Load Case no. 5...WINDLEFT

Node No. ---1 2 3 4 5 6

Vertical Horizontal Moment Vertical Horizontal Rotation Reaction Reaction Reaction Displac. Displac. Angle (kN) (kN) (kN.m) (cm) (cm) (deg) ---------- ---------- ---------- ---------- ---------- ----------60.012 -27.279 0.000 0.000 0.000 -1.564 0.000 0.000 0.000 -0.119 8.189 0.252 -124.070 0.000 0.000 0.000 8.222 -0.136 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.222 8.272 -0.588 -29.766 -11.115 0.000 0.000 0.000 -0.960

Structure Reactions and Displacements - Load Case no. 6...WINDRIGHT

Node No. ---1 2 3 4 5 6

Vertical Horizontal Moment Vertical Horizontal Rotation Reaction Reaction Reaction Displac. Displac. Angle (kN) (kN) (kN.m) (cm) (cm) (deg) ---------- ---------- ---------- ---------- ---------- ----------29.767 11.115 0.000 0.000 0.000 0.960 0.000 0.000 0.000 0.222 -8.272 0.588 -124.069 0.000 0.000 0.000 -8.223 0.135 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 -0.119 -8.190 -0.252 -60.012 27.279 0.000 0.000 0.000 1.564

The summary of reactions at node 3 is as follows: DEAD 25.742 kN LIVE 126.46 kN WINDEND -146.70 kN WINDLEFT -124.07 kN WINDRIGHT -124.07 Kn

DM 03.10.00

4-17

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

Using these reactions jack beam can be designed in DETAIL MODE of ASFAD. The input file can be prepared as follows: *HEADER TITLE:JACKBEAM INIT:MSA *NODES 1 0.000 2 12.000

0.000 0.000

*SUPPORTS 1 X Y 2 X Y *MEMBERS 1 2 0.00 0.00 NNN NNN 400.0 700.0 250.0x15.0 6.0 250.0x12.0 700.0 400.0 250.0x15.0 6.0 250.0x12.0 B 6.0D *LOADS 1 2 DEAD 1 2 DEAD 1 2 LIVE 1 2 WINDLEFT 1 2 WINDRIGHT 1 2 WINDEND STATIC DEAD

GWY GCY GCY GCY GCY GCY

-1.00 -25.74 -126.46 124.07 124.07 146.70

0.00 6.00

6.0 6.0 6.0 6.0 6.0

*LOADCOND 1.00 1.00 DEAD 1.00 LIVE 0.75 1.00 DEAD 1.00 WIND *DESIGN 1 2 KX=1.0 CB=1.75 *END

Step 4: The deflections of Jack Beam are read from detail force summary report shown below. Note the highlighted lines. Member

1 - 2

Section Point @ dist No. No. (m) ---------------1 1 1 1 1 1 1 1 1 1 1

DM 03.10.00

0 1 2 3 4 5 6 7 8 9 10

0.00 0.60 1.20 1.80 2.40 3.00 3.60 4.20 4.80 5.40 6.00

Load Case No.

1 DEAD

Moment (kN.m) --------

Axial (kN) --------

Shear (kN) --------

0.00 10.37 20.46 30.27 39.80 49.05 58.03 66.73 75.14 83.28 91.15

0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

17.51 17.05 16.58 16.12 15.66 15.19 14.73 14.26 13.80 13.33 12.87

Deflection (cm) -------0.000 -0.123 -0.242 -0.352 -0.450 -0.536 -0.607 -0.663 -0.703 -0.727 -0.735

4-18

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

Member

1 - 2

Load Case No.

Section Point @ dist No. No. (m) ---------------1 1 1 1 1 1 1 1 1 1 1 Member

0 1 2 3 4 5 6 7 8 9 10 1 - 2

0.00 0.60 1.20 1.80 2.40 3.00 3.60 4.20 4.80 5.40 6.00

1 1 1 1 1 1 1 1 1 1 1

Member

0 1 2 3 4 5 6 7 8 9 10

1 - 2

0.00 0.60 1.20 1.80 2.40 3.00 3.60 4.20 4.80 5.40 6.00

DM 03.10.00

0 1 2 3 4 5 6 7 8 9 10

Axial (kN) --------

Shear (kN) --------

0.00 37.94 75.88 113.81 151.75 189.69 227.63 265.57 303.50 341.44 379.38

0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

63.23 63.23 63.23 63.23 63.23 63.23 63.23 63.23 63.23 63.23 63.23

0.00 0.60 1.20 1.80 2.40 3.00 3.60 4.20 4.80 5.40 6.00

Deflection (cm) -------0.000 -0.484 -0.950 -1.385 -1.776 -2.118 -2.405 -2.632 -2.796 -2.896 -2.929

3 WINDEND

Moment (kN.m) --------

Axial (kN) --------

Shear (kN) --------

0.00 -44.01 -88.02 -132.03 -176.04 -220.05 -264.06 -308.07 -352.08 -396.09 -440.10

-0.00 -0.00 -0.00 -0.00 -0.00 -0.00 -0.00 -0.00 -0.00 -0.00 -0.00

-73.35 -73.35 -73.35 -73.35 -73.35 -73.35 -73.35 -73.35 -73.35 -73.35 -73.35

Load Case No.

Section Point @ dist No. No. (m) ---------------1 1 1 1 1 1 1 1 1 1 1

Moment (kN.m) --------

Load Case No.

Section Point @ dist No. No. (m) ----------------

2 LIVE

Deflection (cm) -------0.000 0.562 1.103 1.606 2.061 2.457 2.790 3.053 3.243 3.359 3.398

4 WINDLEFT

Moment (kN.m) --------

Axial (kN) --------

Shear (kN) --------

0.00 -37.22 -74.44 -111.66 -148.88 -186.10 -223.33 -260.55 -297.77 -334.99 -372.21

-0.00 -0.00 -0.00 -0.00 -0.00 -0.00 -0.00 -0.00 -0.00 -0.00 -0.00

-62.03 -62.03 -62.03 -62.03 -62.03 -62.03 -62.03 -62.03 -62.03 -62.03 -62.03

Deflection (cm) -------0.000 0.475 0.932 1.358 1.743 2.078 2.359 2.582 2.743 2.841 2.874

4-19

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

Member

1 - 2

Load Case No.

Section Point @ dist No. No. (m) ---------------1 1 1 1 1 1 1 1 1 1 1

0 1 2 3 4 5 6 7 8 9 10

0.00 0.60 1.20 1.80 2.40 3.00 3.60 4.20 4.80 5.40 6.00

5 WINDRIGHT

Moment (kN.m) --------

Axial (kN) --------

Shear (kN) --------

0.00 -37.22 -74.44 -111.66 -148.88 -186.10 -223.33 -260.55 -297.77 -334.99 -372.21

-0.00 -0.00 -0.00 -0.00 -0.00 -0.00 -0.00 -0.00 -0.00 -0.00 -0.00

-62.03 -62.03 -62.03 -62.03 -62.03 -62.03 -62.03 -62.03 -62.03 -62.03 -62.03

Deflection (cm) -------0.000 0.475 0.932 1.358 1.743 2.078 2.359 2.582 2.743 2.841 2.874

Using these deflections the intermediate frame should be redesigned by adding these deflections as nodal settlements in loads header as follows: 3 3 3 3 3

DEAD LIVE WINDEND WINDLEFT WINDRIGHT

S S S S S

Y=-0.735 Y=-2.929 Y= 3.398 Y= 2.874 Y= 2.874

Step 5: Using the reactions of Jack Beam, as loads on the main frame of Step 1 the main adjacent frame should be redesigned. These loads are read from the output file of Jack Beam as follows.: Structure Reactions and Displacements - Load Case no. 1...DEAD

Node No. ---1 2

Vertical Horizontal Moment Vertical Horizontal Rotation Reaction Reaction Reaction Displac. Displac. Angle (kN) (kN) (kN.m) (cm) (cm) (deg) ---------- ---------- ---------- ---------- ---------- ---------17.512 -0.000 0.000 0.000 0.000 -0.119 17.512 -0.000 0.000 0.000 0.000 0.119

Structure Reactions and Displacements - Load Case no. 2...LIVE

Node No. ---1 2

Vertical Horizontal Moment Vertical Horizontal Rotation Reaction Reaction Reaction Displac. Displac. Angle (kN) (kN) (kN.m) (cm) (cm) (deg) ---------- ---------- ---------- ---------- ---------- ---------63.230 -0.000 0.000 0.000 0.000 -0.466 63.230 -0.000 0.000 0.000 0.000 0.466

Structure Reactions and Displacements - Load Case no. 3...WINDEND

Node No. ---1 2

Vertical Horizontal Moment Vertical Horizontal Rotation Reaction Reaction Reaction Displac. Displac. Angle (kN) (kN) (kN.m) (cm) (cm) (deg) ---------- ---------- ---------- ---------- ---------- ----------73.350 0.000 0.000 0.000 0.000 0.540 -73.350 0.000 0.000 0.000 0.000 -0.540

DM 03.10.00

4-20

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

Structure Reactions and Displacements - Load Case no. 4...WINDLEFT

Node No. ---1 2

Vertical Horizontal Moment Vertical Horizontal Rotation Reaction Reaction Reaction Displac. Displac. Angle (kN) (kN) (kN.m) (cm) (cm) (deg) ---------- ---------- ---------- ---------- ---------- ----------62.035 0.000 0.000 0.000 0.000 0.457 -62.035 0.000 0.000 0.000 0.000 -0.457

Structure Reactions and Displacements - Load Case no. 5...WINDRIGHT

Node No. ---1 2

Vertical Horizontal Moment Vertical Horizontal Rotation Reaction Reaction Reaction Displac. Displac. Angle (kN) (kN) (kN.m) (cm) (cm) (deg) ---------- ---------- ---------- ---------- ---------- ----------62.035 0.000 0.000 0.000 0.000 0.457 -62.035 0.000 0.000 0.000 0.000 -0.457

Main frame should be redesigned by adding the loads to the LOADS header as follows: 3 3 3 3 3

DM 03.10.00

4 4 4 4 4

DEAD LIVE WINDLEFT WINDRIGHT WINDEND

GCY GCY GCY GCY GCY

-17.512 -63.230 62.035 62.035 73.350

4-21

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

4.3. Flange braces Lateral stability of compression members/flanges is a very important factor in the design of PEB members, increasing the number of braced points thus decreasing the unbraced length of compression members/flanges improves the performance of these members/flanges under compression forces and increases their compressive strength. When the compression flange is directly connected to roof purlins/wall girts the flange is considered braced at the points of intersection with those members, but when those members are connected with the opposite flange then flange brace angle is required to connect the compression flange with roof purlins/wall girts, the flange brace system comprising flange brace angles and roof purlins/wall girts is providing lateral stability to compression flange. Zamil standard flange brace angle (L50x50x3) is being used as illustrated in the following sketch.

The member/members providing the lateral stability for compression members/flanges must satisfy stiffness and strength requirements. 4.3.1. Brace members requirements 4.3.1.1. Stiffness requirements The minimum stiffness of brace members (Kreq) required to prevent lateral translation is function of (1) :•

• •

Moment of inertia of the compression member or compression flange (I). No. of unbraced segments of the compression member/flange. The unbraced segment length of the compression member or compression flange (L).

The equivalent stiffness of flange brace system comprising brace angles and 5-bays of roof purlins/wall girts as illustrated below usually gives values less than (Kreq) specially with high depths of columns/rafters.

ROOF PURLIN/WALL GIRT

BRACED BAY

(1)

RAFTER/COLUMN

BRACED BAY FLANGE BRACE ANGLE

STEEL STRUCTURES design and behavior Salmon & Johnson (Forth edition)

DM 03.10.00

4-22

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

Brace members with stiffness less than (K req.) give buckling load less than the load defined by Euler’s formula

PE =

π 2 .E.I L2

Where (I) & (L) as described above and (E) is the Young’s modulus = 19995 KN/cm2 Buckling analysis and correlation study was performed in ZAMIL STEEL research and development department in order to obtain the formula governing the value of buckling load of continuous beam (compression flange) on intermediate elastic supports (flange brace system) with stiffness less than (Kreq). The formula was based on calculating the effective buckling length β.L thus the buckling load is calculated as follows:-

PCR =

π 2 .E.I ( βL) 2

The β value is function of (L), (I) and (KACT)

Models with different bay spacing from 5.0m to 9.0m, different web depth from 300mm to 1500mm and 5 unbraced bays with standard purlin sizes (200Z15,200Z20,200Z25) for short and continuous laps and using the standard flange brace angle (L50x50x3) were studied. Equivalent stiffness tables of different cases were established. A Simple spread sheet was developed for the purpose of checking the brace system and the buckling load of the compression flange and decide whether the flange brace system is adequate or not. 4.3.1.2. Strength requirements The required strength for restraint of compression flanges can be summarized in the following rules (1):1) The intermediate lateral restraints should be capable of resisting total force not less than 2.5% of the maximum value of the force in the compression flange within the relevant span, divided between the intermediate lateral restraints in proportion to their spacing but not less than 1% at any braced point at a time. 2) Bracing system that supply intermediate lateral restraint to more than one member should be designed to resist the sum of lateral restraint forces from each member as calculated above reduced by factor (Kr) where (Nr >1) Kr = (0.2+1/Nr)0.5 Nr = Number of parallel members restrained. 3) Purlins adequately restrained by sheeting need not normally be checked for forces caused by restraining rafters of roof trusses or portal frames that carry predominantly roof loads provided that either :  There is bracing of adequate stiffness in the plane of rafter OR  The roof sheeting is capable of acting as a stressed –skin diaphragm.

(1)

BS 5950-1:2000 SECTION 4 CLUASE (4.3.2)

DM 03.10.00

4-23

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

4. Main framing design

4.3.2. Spread sheet for checking flange brace system adequacy

• •

In the section Dim&Grade choose the web depth and fill the rest of section information. In the brace system Choose the bay spacing between frames, purlin size and lap type, no. of intermediate FB along the compression flange, FB profile and fill in the flange braces spacing (L) and No. of restrained frames.

The spread sheet calculates the following:1. The equivalent system stiffness (Eq. system stiffness) according to brace system given data. 2. Section comprised (Compression flange+1/6 web) properties. 3. Euler’s buckling load (PE). 4. The critical buckling load (Pcr) as function of (β). 5. The allowable flange stresses to prevent buckling (fALL-BUCK) =(12*Pcr)/(23*A). 6. The max. expected stresses on compression flange (fx) based on lateral torsional & local buckling and plate girder reduction in accordance with AISC(ASD 1989), the actual stresses from computer analysis(ASFAD) can be overwritten by the user see example next page. 7. The minimum flange brace spacing (Lmin) the system can support the chosen flange brace (L) must be greater than (Lmin). 8. The Required stiffness (Kreq.) to prevent any lateral translation which is corresponding to β=1 thus Euler’s buckling load can be reached, for system stiffness equal to or greater than (Kreq.) critical buckling load (Pcr) = Euler’s buckling load (PE). 9. Flange brace buckling report message is “bracing system is adequate” if (fALL-BUCK) > (fx) otherwise set of recommendations to enhance the system are shown. DM 03.10.00

4-24

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

10. Flange brace angle properties and forces are calculated, angle section is checked under eccentric

compression according to AISC (ASD 1989) part 5, accumulated restraint force depending on the no. restrained frames are also calculated according to (BS 5950-1:2000 SECTION 4 CLUASE (4.3.2)). Example Data : Clear span 40m Bay spacing 7.5m Roof purlin 200z25 Over lap type continuous Loads and restraint are printed out from ASFAD as below :*HEADER TITLE : INIT : CONST: Page=66 Fy=34.50 Fp=0.75 Segment=0.60 Bolt=A325 Moment=0.50 OUTPUT: I R D -C -FC -FM -FP -T -M *SPANS 40.00 EH 8.00 *MEMBERS 500.00 Slope=0.000 Ht=8.000 Girt=200.0 Disp=0.000 250.00 1400.00 x10.00 10.00 250.00x10.00 0.00 Bracing 4.00F 6.00F 8.00F 1350.00 Slope=1.000 Purlin=200.0 End=20.000 250.00 1000.00 x10.00 10.00 250.00x10.00 0.00 200.00 1000.00 x10.00 8.00 200.00x10.00 12.10 Bracing 0.90F 2.65F 4.40F 6.15T 7.90F Bracing 14.90F 17.15T 19.40F Sym

Fy=34.50 Fix=N Conn=2

9.65T

11.40F

13.15T

*LOADS DEAD 0.10 LIVE 1.25 COLL 0.00 SNOW 0.00 P1-100.0 TEMP 0.00 0.00 BAY 7.50 WIND 130.00 CMB86 SFI STATIC 2 DEAD *LOADCOND *AUTODESIGN Vert-Def 180.00 Sway-Def 45.00 #StdAll BC #DwRatio 4.000 #MinThk 0 0 #Max_Kw 180.000 #Max_Kb 35.000 #Max_Uc 1.000 *END

DM 03.10.00

4-25

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

4. Main framing design

ASFAD stresses result (member 2-3): *************************************************************************************** * Member 2 - 3 Length = 19.203 meters Fy = 34.50 kN/cm2 Weight = 2082.760 Kg *************************************************************************************** * Web Depth Top Flange Web Bottom Flange Section Length (....mm....) Section (.....mm.....) thick (.....mm.....) Unity No. (m) Start End type width x thick (mm) width x thick Check ---------- --------------- ------- ---------------- ------ ---------------- ----1 7.103 1350.00 1000.00 I-00 250.00 x 10.00 10.00 250.00 x 10.00 Pass 2 12.100 1000.00 1000.00 I-00 200.00 x 10.00 8.00 200.00 x 10.00 Pass Maximum Forces Allowable Stresses Calculated Stresses Section Moment Axial @ Dist Load (......kN/cm2.....) (......kN/cm2.....) No. (kN.m) (kN) (m) cond Fa Fb-Top Fb-Bott fa fb-Top fb-Bott ---- ---------------------------- --------------------- --------------------1 -1112.38 -207.01 0.65 1 8.85 20.70 20.70 -1.12 17.47 -17.47 2 436.85 -187.00 17.20 1 7.23 20.70 20.70 -1.56 -13.21 13.21

Stress Ratio ------0.97 0.85

Checking bracing System For Comp. Flange Member 2-3 –Section (1) FB Spacing (L) = 175 Choose hw=1400 Bottom flange under compression at dist 0.65

1) Flange Buckling Report gives that the safe buckling stresses (FALL-BUCK) are less than the max. expected stresses, meanwhile the actual stress in the flange may not exceed (FALL-BUCK). 2) FB Angle Stresses in bracing system report is FAIL.

DM 03.10.00

4-26

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

4. Main framing design

Before starting to improve the brace system check (over write fx) by the actual stresses from ASFAD output = (17.47+1.12) = 18.59kn/cm2 Check FB-Profile as a Double.

Messages now are adjusted and the bracing system is adequate for the critical case of loading and no need for system improvement. Force from compression flange was divided between double angle and the stresses are OK.

DM 03.10.00

4-27

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

4.4. Design of Rigid Frame Connections All main frames connections are designed using ASFAD deign package reporting the straining actions and stresses ratios and also the connection codes. In the following section manual calculations procedure of different types of connections are outlined, however finite elements models are now being studied thus figuring out the realistic performance of connections including: actual load distribution, effect of prying forces thus driving manual calculation procedure conforming to the finite elements studies. The results of finite elements studies and revised manual procedure will soon be available for deign engineers. 4.4.1. Design of Pinned Base Plate Two checks shall be made for the required plate thickness of a pinned base plate. One is for bearing, the other for uplift. The larger thickness required by design shall be used as per AISC 9th Edition; page 3-106. Minimum plate thickness shall be 12 mm. I

Plate thickness for bearing: Pc Pt Vmax Vt

= maximum axial compression = maximum axial tension = maximum shear = shear occurring simultaneously with Pt

m

= (D - 0.95 d)/2 for H columns = (D - 0.8 d)/2 for tube columns

n

= (B - 0.8 bf)/2 for H & tube columns

n′ =

db f 4

(applicable to H columns only)

k = m, n, or n′ whichever is highest Allowable bearing pressure fp:

fp =

Pc < 0.35f c′ BD

fc’ is the compressive strength of concrete in kN/cm2 (2.07kN/cm2) Required plate thickness tPL:

t PL = 2k II

fp Fy

≥ 12mm

Plate thickness for uplift:

For an H-shaped column, it is assumed that the components of uplift load, resisted by the column web and flanges are in direct proportion to their distances from the bolts. The bolts are assumed to act as a fixed support for the plate when the latter bends under uplift. The moment arm for plate bending is typically taken

DM 03.10.00

4-28

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

as the distance between the center of the bolt and the centerline of flange or web, less one quarter of the bolt diameter. The following derivations elaborate the bolt force distribution to the webs, flanges and stiffeners: Bolt distribution: Representing the plate in bending as a beam, and assuming that the beams: (i)

are cantilevered and restrained against rotation at one end, and fixed at the other end (@ bolt line).

(ii)

deflect equally at their ends.

(iii)

have approximately the same stiffness

the sketch below serves as a clarification of the beam action:

Note that the moment arm will always be equal to the distance from the center of the bolt to the centerline of the load carrying elements (flange, web, gusset, stiffener) less one quarter of the bolt diameter.

Let P be the bolt load, P1 the bolt load distribution to element 1, and P2 the bolt load distribution to element 2. With the deflections being equal, ∆1 = ∆2 DM 03.10.00

4-29

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

P1 L13/(12EI) = P2 L23/(12EI)

L P1 = P2  2  L1

  

3

since P = P1 + P2 ⇒ P1 = P - P2

or P2 =

P L 1 +  2  L1

L P = P2 + P2  2  L1

3

  

3   L   = P2 1 +  2   L 1 

similarly P1 =

  

3

  

P L 1 +  1  L2

  

3

Three cases will be considered: Base plate with 2, 4 and 6 bolts. i)

Base plate with two bolts:

db = bolt diameter b = 0.5 bf a = 0.5 (h + tf) T = Tension per bolt = 0.5 Pt Uplift Force in web per bolt Pw:

Pw =

Pw =

T 3

 0.5g   0.5g  1+    +  a   a 

3

T  0.5g  1 + 2   a 

3

Uplift Force in each half flange per bolt Pf:

DM 03.10.00

4-30

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

Pf =

T 3

 a  a  +   1 +   0.5g   a 

3

Plate moment due to uplift force in web:

PL (2Pw )(g - 0.5d b ) = 8 8 = 0.25 Pw (g-0.5db)

Pf =

T  a   2 +   0.5g 

3

Plate moment due to uplift force in flange:

PL (Pf )(a - 0.25d b ) = 2 2 = 0.5Pf (a-0.25db) Required plate thickness due to uplift in web is:

t PL =

6M = Fb h

6 x0.25Pw (g - 0.5d b ) = 0.75Fy h

2Pw (g - 0.5d b ) ≥ 12mm Fy h

Required plate thickness due to load to flange is:

t PL =

ii)

6M = Fb b

6x0.5Pf (a - 0.25d b ) 2Pf (a - 0.25d b ) =2 ≥ 12mm 0.75Fy b Fy b

Base plate with four bolts: Tension per bolt: T = 0.25 Pt Uplift Force in web per bolt row (row parallel to web) Pw:

Pw =

2T

 0.5g  1+    a 

3

Uplift Force in each half flange per bolt:

DM 03.10.00

4-31

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

Pf =

T  a   1 +   0.5g 

3

Plate moment due to uplift force in web:

PL (2Pw )(g - 0.5d b ) = 8 8 = 0.25 Pw (g-0.5db)

Plate moment due to uplift force in flange:

PL (Pf )(a - 0.25d b ) = 2 2 = 0.5Pf (a-0.25db) Required plate thickness due to uplift in web is:

6M = Fb h

t PL =

6 x0.25P w (g - 0.5d b ) = 0.75 Fy h

2 Pw (g - 0.5d b ) ≥ 12 mm Fy h

Required plate thickness due to load to flange is:

t PL =

iii)

6x0.5Pf (a - 0.25d b ) 2Pf (a - 0.25d b ) =2 ≥ 12mm 0.75Fy b Fy b

6M = Fb b

Base plate with six bolts: T = Tension per bolt = Pt /6

Uplift Force in web per bolt row (row parallel to web) Pw:

Pw =

DM 03.10.00

2T

 0.5g  1+    a 

3

+T

4-32

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

Uplift Force in each half flange per bolt:

Pf =

T  a   1 +  0.5g  

3

Plate moment due to uplift force in web:

PL (2Pw )(g - 0.5d b ) = 8 8 = 0.25 Pw (g-0.5db)

Plate moment due to uplift force in flange:

PL (Pf )(a - 0.25d b ) = 2 2 = 0.5Pf (a-0.25db) Required plate thickness due to uplift in web is:

t PL =

6M = Fb h

6 x0.25Pw (g - 0.5d b ) = 0.75Fy h

2Pw (g - 0.5d b ) ≥ 12mm Fy h

Required plate thickness due to load to flange is:

t PL =

6M = Fb b

6x0.5Pf (a - 0.25d b ) 2Pf (a - 0.25d b ) =2 ≥ 12mm 0.75Fy b Fy b

Note: In all of the above three conditions, the bending in the plate due to uplift force in the flange was performed by assuming a = a. In case a ≠ a! then an additional set of calculations for bending and required plate thickness shall be made using a' in place of a. The critical of the three computed required plate thicknesses shall be used in design.

DM 03.10.00

4-33

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

iv)

Base plate with four bolts for a tube column:

For tube column, it is assumed that the two tube walls closest to the anchor bolts transmit the uplift load and the plate is fixed at each bolt line: T = Tension per bolt row (on each side of tube)

M=

Tab(a + b) L2

Required plate thickness is:

t PL =

6M = Fb b f

6xTab(a + b) = 0.75Fy b f L2

8Tab ≥ 12mm Fy b f L

Design of Welds: I

H-Columns:

i) Flange welds are designed for the load distribution to the flange from the maximum tension in the column. Maximum required calculated fillet weld (two sides) would be:

Fillet Weld Size (cm) =

Pf ≥ 0.5cm 10.24b f

Where 10.24kN/cm is the allowable flow per one cm for E70XX electrode (Ft = 48.3 kN/cm2) ii)

Web weld is designed for the critical case resulting from two conditions. These are: 1. 2.

Maximum shear reaction Load distribution to the web from maximum tension in the column plus the shear force occurring simultaneously (combined shear and tension action).

Minimum required calculated fillet weld (two sides) would be:

Pw2 + Vt2 Vmax Weld Size(cm) = OR (which ever is greater) 10.24h 10.24h

DM 03.10.00

4-34

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

II

Tube columns:

Since an interior tube column will seldom have a horizontal shear force at its base, it is sufficient to design the weld on the two faces of the tube closest to the anchor bolts to resist the uplift load and then use that weld on all four walls. Minimum required calculated fillet weld (all around tube) should be:

Weld Size (cm) =

Pt 2b f 10.24

Example 1: = 2.068 kN/cm2 f′c = 34.5 kN/cm2 Fy = 125 kN Pc = 50 kN (Due to Wind) Pt Vmax = 25 kN Vt = 20 kN (Due to Wind) Column size: W300x5 + F200x10 Assume base plate size as shown in Fig. Bolt Size: Tension per bolt = 50/4 = 12.5kN

Area of bolt =

12.5 = 0.68cm 2 13.8x1.33

Diameter of bolt = 0.93cm ⇒ Use 2.0 cm (minimum bolt diameter for rigid frame anchor bolts) Plate thickness for bearing:

m = 1/2 (35 - 0.95 x32) = 2.3 cm n = 1/2 (20.0 - 0.8x20.0) = 2.00 cm h = 30.0 cm

n′ = k

32x20 = 6.32cm 4 = n′ = 6.32 cm

Allowable bearing pressure fp:

fp =

DM 03.10.00

125 = 0.178kN/cm 2 < 0.724 (= 0.35f c′ ) 20x35

4-35

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

Required plate thickness tPL:

t PL = 2x6.32

0.178 = 0.91cm 34.5

Use 12 mm plate thickness Plate thickness for uplift: Tension per bolt: T = 0.25 x 50 =12.5kN a=

1/2 (d - tf - p) = 1/2 (32 – 1 - 11) = 10 cm

Uplift Force in web per bolt row (row parallel to flange) Pw:

Pw =

2x12.5

 0.5x10  1+    10 

3

= 22.2kN

Uplift Force in each half flange per bolt row (row parallel to web):

Pf =

12.5

 10  1+    0.5x10 

3

= 1.39 kN

Required plate thickness due to uplift in web is:

t PL =

2x22.2(10 - 1.0) = 0.54cm 34.5x1.33x30

Required plate thickness due to load in flange is:

t PL = 2

2x1.39(10 - 0.5) = 0.34cm 34.5x1.33x20

Use a minimum of 12mm thick plate. Welds: Flange Weld: Maximum required calculated fillet weld (two sides) would be:

Fillet Weld Size (cm) =

1.39 = 0.007cm 10.24x20

Use a minimum of 5mm weld.

DM 03.10.00

4-36

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

ii)

Web weld

Minimum required calculated fillet weld (two sides) would be:

Weld Size(cm) =

25 = 0.04cm (based on maximum shear) 2 x10.24 x30

OR

Weld Size(cm) =

22.2 2 + 20 2 = 0.0486cm (based on combined tension and shear) 2x10.24x30

Use a minimum of 5mm weld Anchor Bolts: i)

Required embedment length:

Allowable bond stress : u =

Use

u

=

0.16 f c′

≤ 0.138 (kN/cm 2 )

db 0.16 2.068 u= = 0.1151 < 0.138 (kN/cm 2 ) 2.0

Required Embedment Length L =

L=

0.1151kN/cm2

T πud b

12.5 = 17.3cm πx0.115x2

Use 55.5cm as per ZS Standard. ii)

Combined shear and tension:

Actual Shear Stress f v =

20 = 1.59kN/cm 2 π 4( ) x4.0 4

Allowable Tensile Stress Ft =17.9-1.8fv 13.8 kN/cm2 Use Ft = 1.33x13.8kN/cm2 = 18.35kN/cm2 (Allowable stress is increased by 33% )

Actual f t =

DM 03.10.00

50 = 3.97kN/cm 2 < 18.35kN/cm 2 OK π 4( ) x4.0 4

4-37

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

Example 2: fc = 2.068 kN/cm2 Fy = 34.5 kN/cm2 = 125 kN Pc Pt = 50 kN (Due to Wind) Vmax = 25 kN Vt = 20 kN (Due to Wind) Bolt Size: Tension per bolt = 50/4 = 12.5kN

Area of bolt =

12.5 = 0.68cm 2 13.8x1.33

Diameter of bolt = 0.93cm ⇒ Use 2.0 cm (minimum bolt diameter for rigid frame anchor bolts) Required thickness for bearing: m = 1/2 (34 - 0.8 x 20) = 9 cm p = 27cm n = 1/2 (23 - 0.8 x 20) = 3.5 cm k = 9 cm Allowable bearing pressure fp:

fp =

125 = 0.16kN/cm 2 < 0.724 (= 0.35f c′ ) 23x34

Required plate thickness tPL:

t PL = 2x9x

0.16 = 1.23cm 34.5

Use 15 mm plate thickness Plate thickness for uplift: Tension per bolt: T = 0.25 x 50 =12.5kN a = 3.5-0.5x0.6 = 3.2 cm b = p – a = 27-3.2 = 23.8 cm L = p – 0.5db = 27 – 0.5x2 = 26 cm (Assume bolt diameter is 2.0 cm) Required plate thickness:

t PL =

DM 03.10.00

8x12.5x3.2x23.8 = 0.565cm 34.5x1.33x26x20 4-38

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

Use a minimum of 12mm thick plate. Welds: Minimum required calculated fillet weld (all around tube) should be:

Weld Size (cm) =

50 = 0.092cm 2x20x10.24x1.33

Use a minimum of 5mm weld Anchor Bolts: i)

Required embedment length:

Allowable bond stress : u = u=

0.16 f c′ db

≤ 0.138 (kN/cm 2 )

0.16 2.068 = 0.1151 < 0.138 (kN/cm 2 ) 2.0

Use u = 0.1151kN/cm2

Required Embedment Length L =

L=

T πud b

12.5 = 17.3cm πx0.1151x2

Use 55.5cm as per ZS Standard. ii)

Combined shear and tension:

Actual Shear Stress f v =

20 = 1.59kN/cm 2 π 4( ) x4.0 4

Allowable Tensile Stress Ft =17.9-1.8fv 13.8 kN/cm2 Use Ft = 1.33x13.8kN/cm2 = 18.35kN/cm2 (Allowable stress is increased by 33% )

Actual f t =

DM 03.10.00

50 = 3.97kN/cm 2 < 18.35kN/cm 2 OK π 4( ) x4.0 4

4-39

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

4.4.2. Design of Fixed Base Plate With the following given data, a fixed base plate assembly can be designed using the method outlined below: = axial compression Pc Pt = axial tension M = bending moment (occurring simultaneously with Pc) = bending moment (occurring simultaneously with Pt) Mt Plate Thickness for Bearing: Bearing pressure at the extreme edges of base plate fp is calculated as:

fp = fa + fb =

Pc 6M ± ≤ Fp A BD 2

Where Fp is the allowable unit contact pressure of the footing. A=BD (Area of base plate) Assuming Size of footing same as base plate size ⇒ Fp = 0.35fc′ Step 1: Assume the base plate dimensions using the detailing guidelines assuming 8 bolt pattern (Refer Detailing Manual Page 32 of Section 5.3) Step 2: Check the base plate dimensions Calculate e = M/P and check for e < D/6 Case I: If e < D/6 ⇒ No tension at the base plate Calculate the extreme pressures as:

f p1 =

Pc 6M + BD BD 2

f p2 =

Pc 6M − BD BD 2

Check that fp1 < ( Fp = 0.35 fc′ ) If fp1 > Fp then calculate B by assuming that fp1 = Fp

B=

Pc 6M + Fp D Fp D 2

Recalculate fp1 and fp2 using new B. Write fp as a function of x (x along D):

DM 03.10.00

4-40

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

 f p1 − f p2 f p = f p1 −   D

 x  

Integrating twice, the moment per unit width expression is obtained.

M PL = f p1

x 2  f p1 − f p2 − 2  D

 x3   6 

Using x = m, calculate MPLm @ critical section and compute thickness of plate

6M PLm 0.75Fy

t PL = Case II:

If e > D/6 ⇒ Tension at the base plate. In this case a procedure using triangular distribution is adopted with maximum pressure = allowable bearing pressure Fp and assuming the maximum allowable stress Ft in the tension bolt simultaneously (balanced condition) Considering the strain compatibility assuming deformed plane section:

εs D - y -c = εc y Where, εs = Ft /Es and εc = Fp /Ec are strains in steel and concrete respectively c = distance from centroid of tension bolts to left edge of plate

⇒ y=

nFp (D - c ) Ft + nFp

n = modular ratio = Es/Ec Resultant Compression R = 0.5ByFp (= Area of pressure diagram shown as shaded) Calculate T = R - P Then calculate the area of bolts in tension:

As =

T Ft

Using 8-bolt pattern calculate area of one bolt (assuming 8 bolts pattern) Ab = As/4 Then calculate Φ of the bar (minimum 20mm Φ) Note: Always add 3mm to the required bolt Φ to account for corrosion.

DM 03.10.00

4-41

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

Calculation of Actual Stresses After obtaining preliminary design data using a balanced condition, now actual stresses are calculated using the accurate analysis. Assume stresses in steel = σs and in concrete = σc under applied loading. For three unknowns y, σs and σc we need three equations. We have 2 equilibrium equations and one compatibility equation as given below: Vertical equilibrium 0.5Byσc- σs As - Pc = 0 ---------------- 1 Moment equilibrium: Taking moment of all forces about column centroid: σs As(0.5D-c)+( σs As + Pc)(0.5D-y/3)-Pce = 0 -------------------- 2 Strain compatibility (plane section after deformation):

εs σ s / Es D - y -c = = ------------------------- 3 εc σ c / Ec y Eliminating σc and σs from these equations gives: y3 + K1 y2 + K2 y + K3 = 0 --------------------------------- 4 Where, K1 = 3 (e – 0.5D)

K2 =

6nA s (0.5D - c + e) B

K3 = K2 (c-D) Equation 4 can be solved using Newton Raphson algorithm: yn+1 = yn – f (y)/f ′(y) From equation 2:

T=

Pc (e + y/3 - D/2) (D - c - y/3)

Tensile stress in bolts: σs = T/As From equation 3:

σc =

σsy ≤ Fp n(D - y - c)

Plate Thickness for Compression: Using the triangular distribution with extreme stress σc calculate stress at distance ‘m’ σcx = σc – x σc / y

DM 03.10.00

4-42

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

Double integrating:

Mx =σc

x2 x3 −σ c 2 6y

m2 m3 −σc Mm = σ c 2 6y t PL =

6M m 0.75Fy

Plate Section w/Stiffener

Note: Thickness of base plate can be restricted by providing edge stiffeners. In this case a revised section modulus of plate considering stiffener size has to be used. Step 3: Bolt Design for Uplift Maximum Tension T in the bolts on one side due to uplift Pt and associated Moment Mt may be calculated based on the assumption that the resultant compression is located at the centroid of bolts on compression side:

T=

M t Pt + Lb 2

Area of bolts on one side = T/Ft Note: Add 3mm to the Φ of bolt to account for corrosion. Step 4: Thickness of Base Plate for Uplift Moment in the plate MPL = TL/8 Where, P = Tension in the bolts (tension side) L = p-0.5db p = centriodal distance from the outside of bolts to inside bolts.

t PL =

6M PL 0.75Fy b f

bf : width of flange Step 5: Welding of Flanges & Web to the Base Plate Force in the tension flange is greater of:

M P  bf x t f x − c  Sx A c 

and

M P  bf x t f x t + t   Sx A c 

Where, Sx and Ac are section modulus and area of cross section of column section at base. Required fillet weld on flange (both sides) = Flange Tension/ (2xbfx10.24) Required fillet weld on web (both side) = Shear (V) / (hw x10.24x2) DM 03.10.00

4-43

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

Note: Minimum weld size is 5mm; Increase stresses by 33% for wind induced forces. Step 6: Embedment Length of Bolt Required Embedment Length = Tension in one bolt / (πµdb) Step 7: Check for Stiffener If k 30. Thickness of stiffener shall be maintained same as thickness of flange tf. -----------------------------------------------------------------------------------------------------------Example: M= 200kN-m Pc = 85kN Pt = 12kN (Due to Wind) Mt = 130kN-m (Due to Wind) V= 55kN d= 800mm; bf = 200mm; tf = 10mm; tw = 5mm; Sx of Column = 2120.7cm3; A = 80cm2; Fy = 34.5kN/cm2; fc′=2.07kN/cm2 Assume Base Plate sizes as per the guidelines provided in the detailing manual page 32 of 5.3 Assume 8-Bolt Pattern (FC-8) Preliminary Design (Estimate Bolt Size): i) Check for Compression: Assume D=820+250=1070mm; B=250mm; c=65+60=125mm; n=9; Ft=13.8kN/cm2 e = M/P = 20000/85 =235 > D/6 Use Triangular Pressure Distribution at base Depth of neutral axis y:

y=

nFp (D - c ) Ft + nFp

=

9 x0.724x(10 7 - 12.5) = 30.31cm 13.8 + 9 x0.724

Resultant Compression R = 0.5ByFp=0.5x25x30.31x0.724=274.3 kN

Calculate T = R – P = 274.3-85 = 189.3 kN Then calculate the area of bolts in tension:

As =

T 189.3 = = 13.72cm 2 Ft 13.8

Ab = 13.72/4=3.43cm2 ⇒ Φ = 20.89+3 =23.89mm ⇒ Use 28mm Φ bolts

DM 03.10.00

4-44

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

ii)

Check for Uplift:

T=

M t Pt 13000 12 + = + = 164.5kN Lb 2 82 2

Area of bolts on one side = T/Ft = 164.5/(13.8x1.33)= 8.96cm2 Ab = 8.96/4=2.24cm2 ⇒ Φ = 16.9+3=19.9 mm Use 8-Bolt Pattern with 24 Φ bolts Edge Distance = 55mm Length of Base Plate = 800 + 20 + 2 x (55+60) = 1050mm Width of Base Plate = 2 x (55+60) = 230mm Check for Actual Stresses Plate Thickness for Bearing: Eccentricity e = M/P = 20000/85 = 235.3cm modulur ratio ‘n’ = 9 Coefficients of cubic equation: K1 = 3 (e – 0.5D) = 3x (235.3-0.5x105) = 548.4

K2 =

6nA s (0.5D - c + e) 6 x9x18.1x(0 .5x105 - 11.5 + 235 .3) = = 11,738 B 23

K3 = K2 (c-D)=11738 x (11.5-105)= -1,097,568 y3 + 548.4y2 + 11738y-1097568 = 0 Using Newton Raphson Algorithm: yn = yn-1 – f(yn-1 )/f′(yn-1) f(y) = y3 + 548.4y2 + 11738y-1097568 f′(y) = 3y2 + 1097y+11738 Assume yo = 0.5x105 = 52.5cm y1 = 53.5 – 1174908 / 77599 = 37.36cm y2 = 37.36 – 158509 / 56908 = 34.57cm Similarly y3 = 34.48cm y4 = 34.48cm ⇒ convergence ⇒ y = 34.48cm From equation 2:

T=

Pc (e + y/3 - D/2) 85x(235.3 + 11.49 - 52.5) = = 201.38kN (D - c - y/3) 105 - 11.5 - 11.49

Tensile stress in bolts: σs = T/As = 201.38/18.1 = 11.13kN/cm2 Allowable Tensile stress Ft = 17.9-1.8fv < 13.8kN/cm2 fv = V/(2As)=55/(2x18.1)=1.52kN/cm2 Ft = 17.9-1.8x1.52=15.16kN/cm2 > 13.8kN/cm2 – Use Ft = 13.8kN/cm2 DM 03.10.00

4-45

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

From equation 3:

σc =

σsy 11.13x34.48 = = 0.722kN/cm 2 < 0.724kN/cm 2 (Fp ) - - - -OK n(D - y - c) 9x(105 - 34.48 - 11.5)

Plate Thickness for Compression: Using the triangular distribution with extreme stress σc calculate stress at distance ‘m’ m = 0.5 (D-0.95d) = 0.5 (105-0.95x82) = 13.55cm

Mm = σ c

tm =

 13.55 2 13.55 3  m2 m3  = 57.6kN - cm/cm −σ c = 0.722x − 2 6y 6x34.48   2

6M m = 0.75Fy

6x57.6 = 3.65cm 0.75x34.5

n = 0.5 (B –0.8bf) = 0.5 (23-0.8x20) = 3.5cm

σ Fy

c Use 38mm = plate. t n =thick 2n base 2x3.5

0.6 = 0.92cm 34.5

Thickness of Base Plate for Uplift Moment in the plate MPL = TL/8 = 201.4x(12-0.5x2.4)/8 =271.9kN-cm

t PL =

6M PL 6 x271.9 = = 1.78cm < 3.8cm - - OK 0.75Fy b f 0.75x34.5x20

Welding of Flanges & Web to the Base Plate Force in the tension flange is greater of:

M P   20000 85  −  = 167.4kN b f x t f x  − c  = 20x1.0x   2121 80  Sx A c  M P  13000 12  +  = 125.6k b f x t f x  t + t  = 20x1.0x   2121 80   Sx A c  Required fillet weld on flange = 167.4/ (2x20x10.24) = 0.41cm Use 5mm weld to the flanges all around Required fillet weld on web = V / (hw x10.24x2) = 55 / (80x10.24x2) = 0.034cm Use minimum 5mm weld on web. Embedment Length of Bolt Tension in one bolt = 164.5/4 = 41.125kN Required Embedment Length = 41.125/ (π x 0.096 x 2.4) = 56.9cm

DM 03.10.00

4-46

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

4.4.3. Design of horizontal knee connection Five sizes of A325N bolts are used in moment connections. These are 16mm φ, 20mm φ, 24mm φ, 27mm φ, 30mm φ bolts. There are two types of connections that may be used for a knee splice. Type I, which contains two bolts per row, and Type II, which contains four bolts per row. Each type is further sub-divided into three different cases by increasing the total number of bolts and/or adding stiffeners to the splice for each case. The sketches shown are of three cases of Type I. Dimension X of stiffeners = 0.5 (W f - tw) Dimension Y = 1.5X Note that if ‘e’ is greater than 600 mm, provide one row of “stitch” bolts (total of two) at mid-span of knee. These bolts are not considered in the analysis of the connection.

Typical Values (mm) Bolts < 24mm φ a 105 b 60 c 60 g 100 p 100 f 45

Bolts > 24mm φ 135 80 60 120 120 55

X1 = a - tf Y1 = 1.5X1 Stiffeners and holes shown in dashed lines are optional.

DM 03.10.00

4-47

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

The analysis of the connection assumes that the bolts on one end resist the tensile stress whereas the flange, stiffeners (if present) and a portion of the web resist the compressive stress. Each of the bolts (acting in tension) distributes its load to the adjacent elements in direct proportion to the relative distances of these elements from the bolt. The procedure outlined below shall be followed for the connection analysis and design: 1.

Compute y and I of an equivalent section comprising the bolts acting in tension and the other elements acting in compression.

2.

Calculate P/A ± Mc/I for the extreme bolts and for the compression flange.

3.

Check for the allowable bolt load and compression flange stress.

4.

If not adequate, search for another connection case with more and/or larger bolts, or with additional stiffeners, and repeat steps 1 through 3.

5.

Calculate required cap plate thickness based on plate bending.

6.

Compare actual element stresses in tension to an allowable stress equal to 0.6 Fy.

7.

Compute all required weld sizes.

8.

Check web thickness in knee area for shear and reinforce with an additional stiffener at mid-span of knee if necessary. As an alternative use a thicker web in the knee area.

The detailed procedure is elaborated in the following example. Example: M = 366 kN-m Pc = 62 kN V = 67 kN Column depth = 1200 mm; Girt depth = 200 mm; Rafter Web depth = 1200 mm Type I, case 2 without stiffeners Bolts: 10 φ 20 mm A325N bolts Column bf = 250 mm; Column tf = 10 mm; Column tw = 8 mm; Rafter tw = 10 mm Gusset tg = 10 mm (Stiffener C); Fy = 34.5 kN/m2 Step I: Calculation of neutral axis depth y:

Bolts: Row # 1 Row # 2 Row # 3 Web: Flange: Total:

y=

Area, A, cm2 6.283 6.283 6.283 0.8(y –1.0) 25.00 0.8y + 43.05

y cm 127.0 117.0 107.0 0.5(y – 1) + 1 0.5

(A) (y) cm3 797.965 735.133 672.300 0.4 y2 - 0.400 12.500 0.4y2 + 2,217.5

ΣAy 0.4 y 2 + 2217.5 ⇒ y = 38.1cm = 0.8y + 43.05 ΣA

DM 03.10.00

4-48

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

Calculation of I: Compute the moment arm for each element: Bolts, row # 1: d = 127.0 - 38.1 = 88.9 cm Bolts, row # 2: d = 117.0 - 38.1 = 78.9 cm Bolts, row # 3: d = 107.0 - 38.1 = 68.9 cm Web: d = 38.1 – [0.5(38.1-1.0) +1.0] = 18.55 cm Flange: d = 38.1 - 0.5 = 37.6 cm

Bolts: Row # 1 Row # 2 Row # 3 Web: Flange: Total:

Area, A cm2 6.283 6.283 6.283 29.68 25.00 A 73.53 cm2

Arm, d cm 88.9 78.9 68.9 18.55 37.6

(A) (d2) cm4 496.6 x 102 391.1 x 102 298.3 x 102 102.1 x 102 353.4 x 102 I = 1.676 x 105 cm4

I0 34.04 x 102 -

Step 2: Actual Stresses:

f=

P Mc ± A I

Stress in bolts =

62 36600 x88.9 − = −18.57 kN/cm 2 5 73.53 1.676 x10

Load in bolts = 18.57 x 3.14 cm2 = 58.3 kN per bolt

Stress in compression flange =

62 36600 x37.6 + = 9.05kN/cm 2 5 73.53 1.676x10

Step 3: Allowable Stresses: Shear stress fv = 67/ (10 x 3.14) = 2.13kN/cm2 Allowable tensile stress in A325 bolts Ft:

Ft = 30.34 2 − 4.39f v2 = 30.34 2 − 4.39x2.13 2 = 30kN/cm 2 > 18.57kN/cm 2 - - - OK Allowable stress in Flange: Fb = 0.6 Fy = 0.6 x 34.5 = 20.7kN/cm2 > 9.05kN/cm2 ----OK Step 5: Plate Thickness i)

Loads in Bolts:

Load in bolt row # 1 = 58.3 kN / bolt DM 03.10.00

4-49

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

36600x78.9   62 − Load in bolt row #2 =   x3.14 = 51.5 kN / bolt 5  73.53 1.676x10  36600 x68.9   62 Load in bolt row #3 =  −  x3.14 = 44.6 kN / bolt 5  73.53 1.676x10  Bolt distribution from row # 1 (distribution from each bolt):

58.3

Load distributed to gusset =

 5.0  1+    5.5 

3

58.3

Load distributed to flange =

 5.5  1+    5.0 

3

= 33.3 kN

= 25.0 kN

Bolt distribution from row # 2 (distribution from each bolt): Load distributed to flange =

Load to web

51.5  4.5  1+    5.0 

3

51.5

=

 5.0  1+    4.5 

3

= 29.8 KN

= 21.7 KN

Bolt distribution from row # 3: Load to web

=

44.6 kN (Neglecting distributed load to flange)

The bolt distribution is assumed to be distributed on each element as follows: Flange :

Over entire width of flange.

Web: Over a distance equal to the bolt pitch, or the physically available distance if the latter is smaller (this may be applicable to distribution from row # 2 or distribution from row adjacent to a stiffener). Gusset :

Over entire width of gusset.

Stiffener: ii)

Over entire width of stiffener.

Plate moment: Typically, the moment and required plate thickness equations are: M = Pi Li/2

t= DM 03.10.00

6M ≥ 12mm Fb b i 4-50

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

Where Pi = Distributed Load to element Li = L - ¼ bd Fb = 0.75 Fy bi = distribution width for the element in question. M due to gusset load = 33.3 x (5.0 cm - 0.5 cm)/2 = 75.0 kN-cm

6x75 = 1.32cm 0.75x4.5x10

t=

M due to flange load = 25 x 5.5 / 2 = 68.8 kN-cm Or 29.8 x 4.5 / 2 = 67.1 kN-cm Use M = 68.8 kN-cm

6x68.8 = 1.13cm 0.75x4.5x12.5

t=

M due to web load from row # 2 = 21.7 x 4.5 / 2 = 48.9 kN-cm

6x48.9 = 1.12cm 0.75x4.5x(4.0 + 5.0)

t=

M due to web load from row # 3 = 44.6 x 4.5 / 2 = 100.35 kN-cm t=

6x100.35 = 1.52cm 0.75x4.5x10

Use a 20 mm cap plate Step 5: Tensile stresses: Allowable stress = 0.6 x 34.5 = 20.7 kN/cm2

Actual stress =

ΣPi t i bi

Gusset stress =

2 x 33.3 = 7.01 kN/cm 2 < 20.7 kN/cm2 1.0 x9.5

Flange stress =

25 + 29.8 = 4.38 kN/cm 2 < 20.7 kN/cm2 12.5x1.0

Web stress =

2 x 21.7 = 6.02 kN/cm2 < 20.7 kN/cm2 9 .0 x 0 .8

Or

2 x 44.6 =11.15 kN/cm2 < 20.7 kN/cm2 10 x 0.8

DM 03.10.00

=

4-51

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

Step 6: Welds: Note the following general rule: Lgusset = 1.5 x W gusset Lstiffener = 1.5 x W stiffener Gusset weld to column flange and rafter end plate (fillet both sides) =

66.6 = 0.23 cm 1.5x9.5x10.24 x 2

Use 5 mm fillet both sides Gusset weld to cap plate (fillet both sides) =

66.6 = 0.33 cm 9.5x10.24 x 2

Use 5 mm fillet both sides Flange weld to cap plate (fillet one side) =

2(25 + 29.8) = 0.428 cm 25.0 x10.24

Use 5 mm fillet one side Web weld to cap plate (fillet one side) =

2 x 21.7 2 x 44.6 or = 0.47 cm or 0.871 cm 9.0 x10.24 10x10.24

Use 5 mm fillet both sides Note that if a larger than desired weld size is required by calculation, then the Design Engineer may cut down that weld size by half by specifying the weld on both sides instead. Step 7: Knee web shear: Total shear = bolt loads = 58.3 x 2 + 51.5 x 2 + 44.6 x2 = 308.8 kN

V 308.8 = = 2.57 kN/cm2 dt w 120 x1.0 120 = 120 h/tw = 1 .0

fv =

a/h ≈ 1.0

⇒ kv = 9.34 ⇒ Cv = 0.583 ⇒ Fv = 6.96 kN/cm2

Where,

Cv =

31034k v Fy (h/t w )

2

; k v = 4.00 +

Fy 5.34 and Fv = (C v ) 2 2.89 (a/h)

Since fv < Fv OK Note: A similar analysis and design shall be performed for the positive moment (inside flange in tension).

DM 03.10.00

4-52

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

4. Main framing design

Design Sketch:

Gusset plate of 10cm width can be notched to fit in the available 9.5cm projection of cap plate

DM 03.10.00

4-53

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

4.4.4. Design of rafter intermediate & ridge splices For rafter and ridge splices, the design is based on a selection from two different cases, all of the type I (2 bolts per row) series. The bolts, bolt gages, bolt pitches, dimensions a, b, c & f and method of analysis and design are similar to those previously outlined for a knee connection, with the exception that the design moment shall be at least equal to one third of the section capacity as a minimum. Normally design moment is assumed to be 50% of the section capacity (0.3Fy Sx). Stiffeners and bolts represented by a dashed line are optional.

Dim. a b c g p f

DM 03.10.00

Bolt Size < 24mm > 24mm 115 70 60 100 100 45

135 80 60 120 120 55

4-54

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

4.4.5 Design of Pinned Cap Plate Design of cap plate involves design checks for thickness of cap plate, thickness of rafter bottom splice plate and size of stiffener. The procedure is outlined in the example as shown below. The rafter web above the interior column shall always contain a bearing stiffener. Example: Pc

= 200 kN Pt = 90 kN (Due to Wind Load) Design cap plate, rafter bottom flange and the stiffener

Cap Plate Design

T = 0.25x90 = 22.5 kN/bolt Allowable Ft in the absence of shear is 30.3kN/cm2 (44ksi)

db =

4T 4x22.5 = = 0.84cm πFt πx30.3x1.33

Use 4-16mm Ø A325 bolts = 0.5S - 0.5d - 0.25db + 0.5 t Moment Arm (L1) = 0.5 (27.0) - 0.5 (15.0) - 0.25 (1.6) + 0.5 (0.45) = 5.825 cm

DM 03.10.00

4-55

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

M=

TL 1 22.5x5.825 = = 65.53kN - cm 2 2

6M 6x65.53 = = 1.523cm 0.75Fy (0.5d) 0.75x34.5x1.33x0.5x15

t PL =

Use 20 mm cap plate Bottom Rafter Splice Plate

Uplift force in web (per row of bolt) Pw =

Pw =

2x22.5  0.5x7  1+    0.5x27 

3

2T  0.5g  1+    0.5s 

3

= 44.23kN

Load to each stiffener (Ps) = [Pt - 2Pw] (0.5) Ps = [90 - (2) (44.23)](0.5) = 0.77 kN (negligible)

M plate =

Pw ( g − 0.5d b ) 44.23(7 − 0.5x1.6) = = 34.28kN 8 8

t plate =

6M 6x34.28 = = 0.419cm 0.75Fy D 0.75x34.5x1.33x34

Use 10mm rafter flange Stiffener Area = (2) (9.8) (1.0) + (34) (0.4) = 33.2 cm2

I=

DM 03.10.00

1.0x20 3 + 34x0.4 3 = 666.85cm 4 12

4-56

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

r=

I 666.85 = = 4.48cm A 33.2

Stiffener length = 65.0-1.0 = 64 cm

KL 0.75x64 = = 10.71 ⇒ Fa = 20.22kN/cm 2 r 4.48 fa =

P 200 = = 6.02kN/cm 2 A 33.2

fa < Fa --- OK Stiffener Welds:

Weld to flange =

200 = 0.5cm 2x(9.8 + 9.8)10.24

Use 6mm weld

Weld to web =

200 = 0.15cm 2x64x10.24

Use 4mm weld

DM 03.10.00

4-57

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

4. Main framing design

4.5. Standard Frame Connections Codes 4.5.1 Anchor Bolt Pattern Codes I) Pinned Base Details for By-Framed Columns

* For bolts pitch & edge spacing refer to updated E-drive

DM 03.10.00

4-58

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

4. Main framing design

II) Pinned Base Details for Flush Columns

* For bolts pitch & edge spacing refer to updated E-drive

DM 03.10.00

4-59

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

4. Main framing design

III) Pinned Base & Cap Plate Details for Interior Tube Columns

* For bolts pitch & edge spacing refer to updated E-drive

DM 03.10.00

4-60

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

4. Main framing design

IV) Pinned Base & Cap Plate Details for Interior Built-Up Columns

* For bolts pitch & edge spacing refer to updated E-drive

DM 03.10.00

4-61

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

4. Main framing design

V) Fixed Base Details with 8-Bolt Pattern

DM 03.10.00

4-62

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

4. Main framing design

VI) Fixed Base Details with 16-Bolt Pattern

DM 03.10.00

4-63

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

4.5.2

4. Main framing design

Knee Connections

I) Horizontal Knee Connection Details

II) Vertical Knee Connection Details

DM 03.10.00

4-64

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

4. Main framing design

III) Vertical Knee Connection (straight column)

4.5.3 Rafter Splice Codes I) Ridge Splice Details

DM 03.10.00

4-65

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

4. Main framing design

II) Rafter Splice Details

DM 03.10.00

4-66

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

4. Main framing design

4.6. Standard Anchor Bolts

DM 03.10.00

4-67

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

Design of Anchor Bolts (Conforming to ASTM A-36 Steel) •

Design for pure Tension Allowable Tensile Stress Ft = 0.33 Fu



Design for Shear Allowable Shear Stress Fv = 0.17 Fu



Design for Tension combined with shear Allowable Tensile Stress Ft = 17.94 -1.8*fv < 13.8kN/Cm2



Embedment Length

Allowable Bond Stress u (kN/cm2) :

u=

0.16 f c′ db

≤ 0.138 kN/cm 2

Where, db= diameter of bolt in cm Required Embedment Length Le:

Le =

T uπd b

Where, T is maximum tension in bolt (in kN)

DM 03.10.00

4-68

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

4.7. Welding Procedure All the welding design in pre-engineered building is in accordance with the specifications of American Welding Society (AWS-1996). The standard welding procedures are outlined in this section. The design engineer should check the adequacy of the welds under the given loading and design the weld considering the guidelines provided herein. 4.7.1.Types of Welds and Standard Sizes LEGEND:

TABLE 2.2 AWS. D1-1-1996

DM 03.10.00

4-69

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

4. Main framing design

4.7.2. Main Frame with Horizontal Knee Connection

DM 03.10.00

4-70

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

4.7.3. Vertical Knee Connection

4.7.4. Interior Columns Connections

INTERIOR COLUMN

DM 03.10.00

MULTI GABLE INTERMEDIATE CONN.

4-71

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

4.7.5. Ridge Splices

HOT ROLLED & BUILT UP PEAK SPLICE

COLD FORM PEAK SPLICE

4.7.6. Base Plate of Cold-Formed EW Post

BASE PLATE OF END WALL POST

DM 03.10.00

4-72

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

4.7.7. Mezzanine Connections

MEZZANINE BRACKET

MEZZANINE END PLATE

MEZZANINE CONN

MEZZANINE BEAM CONNECTION PLATE

JOIST SEATED CONNECTION

DM 03.10.00

4-73

ZAMIL STEEL BUILDINGS DESIGN MANUAL 4. Main framing design

PEB DIVISION

4.7.8. Crane Beam

BUILT-UP SECTION W/OUT TOP FLANGE

CRANE BEAM CAP CHANNEL

BUILT-UP SECTION W/ TOP FLANGE

HOT ROLLED SECTION

SEC. A-A

DM 03.10.00

A

B

A

B

SEC. B-B

4-74

ZAMIL STEEL BUILDINGS DESIGN MANUAL 5. Secondary members design

PEB DIVISION

CHAPTER 5: SECONDARY MEMBERS DESIGN The secondary members in the PEB system includes panels, roof purlins, side walls girts, end wall girts and eave struts 5.1. Panels Two types of panels are used in PEB buildings single skin panels and tempcon panel 5.1.1. Single Skin Panels Single skin panels are used as roof and wall sheeting, roof and wall liners, partition and soffit sheeting. The panel profiles currently under use as follows: 1. 2. 3. 4. 5. 6. 7.

Type ‘A’ - High-Rib Panel Type ‘D’ – Sculptured Z-liner panel Type ‘E’ - Flat Z-Liner Panel Type ‘G’ - Deep Rib Panel Type ‘R’ Type ‘S’ Type ‘K’

The roof panels are normally plain zincalume that may be upgraded to all Zamil Steel’s standard colors while the wall panels are always used in standard colors. The liner panels are used to conceal the roof purlins, wall girts and the fiber glass insulation on the inside of the building when neat finished appearance is required. Zamil Steel raw material stock for metal panels consists of Steel Coils and Aluminum Coils 5.1.1.1. Steel Panels The standard specification for the base material of steel coil is conforming to ASTM A-792 Grade 50-B with minimum yield strength of 34.5 KN/cm2. Zamil Steel offers three types of exterior face finish coatings for its steel panels, which are: 1) 2) 3)

‘XRW’ ‘XPD’ ‘XSE’

Exterior Roof and Wall Exterior Premium Durability Exterior Severe Environment

The section properties and allowable loads for the steel panels are shown in Tables 5.1.1 to 5.1.7. Since Type ‘D’ and ‘E’ panels have similar properties and allowable loads, load table for only Type ‘E’ has been provided.

DM 03.10.00

5-1

ZAMIL STEEL BUILDINGS DESIGN MANUAL 5. Secondary members design

PEB DIVISION

Table 5.1 - Type “A” Steel Panel

Panel Thickness mm 0.50 0.60 0.70

Weight 2 kg/m

Area 2 cm

Ix 4 cm

4.99 5.99 6.99

6.36 7.63 8.90

4.05 5.13 6.15

Top in Compression Zx-Top Zx-Bott. 3 3 cm cm 2.15 2.96 3.64

4.97 6.30 7.61

Ma kN.m 0.44 0.61 0.75

Ix 4 cm

Bottom in Compression Zx-Top Zx-Bott. 3 3 cm cm

3.44 4.50 5.61

2.22 2.83 3.44

3.14 4.31 5.55

Ma kN.m 0.46 0.58 0.71

Web Shear & Cripp. Va Pa kN kN 11.89 5.97 18.58 9.44 25.45 13.40

Allowable loads in kN/m2 Panel Thickness mm

Number of Spans 1

0.50

2

3

1

0.60

2

3

1

0.70

2

3

• • • •

Load Case

1.00

1.25

1.50

1.75

Span in meters 2.00 2.25

2.50

2.75

3.00

3.50

D+L WP WS D+L WP WS D+L WP WS D+L WP WS D+L WP WS D+L WP WS D+L WP WS D+L WP WS D+L WP WS

3.45 4.69 4.40 3.68 4.91 4.69 4.60 6.13 5.87 4.38 6.51 5.76 4.64 6.19 6.51 5.80 7.73 8.13 5.25 7.87 7.18 5.68 7.58 8.00 7.10 9.46 10.00

1.77 2.65 2.25 2.36 3.14 3.00 2.94 3.92 3.75 2.24 3.36 2.95 2.97 3.96 4.17 3.71 4.95 5.20 2.69 4.03 3.68 3.64 4.85 5.12 4.54 6.06 6.40

1.02 1.54 1.30 1.64 2.18 2.09 1.93 2.73 2.46 1.30 1.95 1.71 2.06 2.75 2.89 2.45 3.44 3.22 1.55 2.33 2.13 2.52 3.37 3.56 2.93 4.21 4.01

0.64 0.97 0.82 1.20 1.60 1.53 1.22 1.82 1.55 0.82 1.23 1.07 1.52 2.02 2.13 1.54 2.31 2.03 0.98 1.47 1.34 1.85 2.47 2.61 1.85 2.77 2.53

0.43 0.65 0.55 0.92 1.23 1.17 0.82 1.22 1.04 0.55 0.82 0.72 1.16 1.55 1.63 1.03 1.55 1.36 0.66 0.98 0.90 1.42 1.89 2.00 1.24 1.86 1.69

0.22 0.33 0.28 0.53 0.79 0.68 0.42 0.63 0.53 0.28 0.42 0.37 0.68 0.99 0.89 0.53 0.79 0.70 0.34 0.50 0.46 0.81 1.21 1.10 0.63 0.95 0.87

0.17 0.25 0.21 0.40 0.60 0.51 0.31 0.47 0.40 0.21 0.32 0.28 0.51 0.76 0.67 0.40 0.60 0.52 0.25 0.38 0.35 0.61 0.91 0.83 0.48 0.71 0.65

0.13 0.19 0.16 0.31 0.46 0.39 0.24 0.36 0.31 0.16 0.24 0.21 0.39 0.59 0.51 0.31 0.46 0.40 0.19 0.29 0.27 0.47 0.70 0.64 0.37 0.55 0.50

0.08 0.12 0.10 0.19 0.29 0.25 0.15 0.23 0.19 0.10 0.15 0.13 0.25 0.37 0.32 0.19 0.29 0.25 0.12 0.18 0.17 0.30 0.44 0.40 0.23 0.35 0.32

D + L = Dead + Live Load WP = Wind Pressure WS = Wind Pressure Material conforming to ASTM or equivalent

DM 03.10.00

0.30 0.46 0.39 0.73 0.97 0.93 0.57 0.86 0.73 0.38 0.58 0.51 0.92 1.22 1.22 0.73 1.09 0.95 0.46 0.69 0.63 1.11 1.50 1.51 0.87 1.30 1.19

(Deflection limit Span/180) (Deflection limit Span/120) (Deflection limit Span/120) 2 A792 Grade 50B (Fy = 34.5 kN/cm )

5-2

ZAMIL STEEL BUILDINGS DESIGN MANUAL 5. Secondary members design

PEB DIVISION

Table 5.2 - Type “E” Steel Panel

Panel Thickness mm

Weight kg/m2

Area cm2

Ix cm4

0.50 0.60 0.70

5.38 6.45 7.53

6.85 8.22 9.59

1.93 2.62 3.36

Top in Compression Zx-Top Zx-Bott. cm3 cm3 1.17 1.62 2.13

1.82 2.33 2.87

Ma kN.m

Ix cm4

0.24 0.33 0.44

3.00 3.89 4.82

Bottom in Compression Zx-Top Zx-Bott. cm3 cm3 7.94 10.00 12.09

1.36 1.76 2.17

Ma kN.m 0.28 0.36 0.45

Web Shear & Cripp. Va Pa kN kN 3.67 4.58 5.50

4.09 6.37 8.94

Allowable loads in kN/m2 Panel Thickness mm

Number of Spans 1

0.50

2

3

1

0.60

2

3

1

0.70

2

3

• • • •

Load Case

1.00

1.25

1.50

1.75

Span in meters 2.00 2.25

2.50

2.75

3.00

3.50

D+L WP WS D+L WP WS D+L WP WS D+L WP WS D+L WP WS D+L WP WS D+L WP WS D+L WP WS D+L WP WS

1.65 2.47 2.99 2.24 2.99 2.56 2.80 3.73 3.20 2.23 3.35 3.84 2.88 3.84 3.52 3.60 4.80 4.40 2.87 4.30 4.80 3.60 4.80 4.69 4.50 6.00 5.87

0.84 1.26 1.91 1.43 1.91 1.64 1.59 2.39 2.05 1.14 1.72 2.46 1.84 2.46 2.25 2.16 3.07 2.82 1.47 2.20 3.07 2.30 3.07 3.00 2.77 3.84 3.75

0.49 0.73 1.14 1.00 1.33 1.14 0.92 1.38 1.42 0.66 0.99 1.48 1.28 1.71 1.56 1.25 1.87 1.96 0.85 1.27 1.83 1.60 2.13 2.09 1.60 2.40 2.61

0.31 0.46 0.72 0.73 0.98 0.84 0.58 0.87 1.04 0.42 0.63 0.93 0.94 1.25 1.15 0.79 1.18 1.44 0.53 0.80 1.15 1.18 1.57 1.53 1.01 1.51 1.92

0.21 0.31 0.48 0.50 0.74 0.64 0.39 0.58 0.80 0.28 0.42 0.62 0.67 0.96 0.88 0.53 0.79 1.10 0.36 0.54 0.77 0.86 1.20 1.17 0.68 1.01 1.46

0.11 0.16 0.25 0.25 0.38 0.41 0.20 0.30 0.46 0.14 0.21 0.32 0.35 0.52 0.56 0.27 0.40 0.60 0.18 0.28 0.39 0.44 0.66 0.75 0.35 0.52 0.74

0.08 0.12 0.18 0.19 0.29 0.34 0.15 0.22 0.35 0.11 0.16 0.24 0.26 0.39 0.47 0.20 0.30 0.45 0.14 0.21 0.30 0.33 0.50 0.62 0.26 0.39 0.56

0.06 0.09 0.14 0.15 0.22 0.28 0.12 0.17 0.27 0.08 0.12 0.18 0.20 0.30 0.39 0.16 0.23 0.35 0.11 0.16 0.23 0.26 0.38 0.52 0.20 0.30 0.43

0.04 0.06 0.09 0.09 0.14 0.21 0.07 0.11 0.17 0.05 0.08 0.12 0.13 0.19 0.28 0.10 0.15 0.22 0.07 0.10 0.14 0.16 0.24 0.34 0.13 0.19 0.27

D + L = Dead + Live Load WP = Wind Pressure WS = Wind Pressure Material conforming to ASTM or equivalent

DM 03.10.00

0.14 0.22 0.34 0.35 0.52 0.51 0.27 0.41 0.63 0.20 0.29 0.44 0.47 0.71 0.70 0.37 0.56 0.82 0.25 0.38 0.54 0.61 0.90 0.93 0.47 0.71 1.02

(Deflection limit Span/180) (Deflection limit Span/120) (Deflection limit Span/120) 2 A792 Grade 50B (Fy = 34.5 kN/cm )

5-3

ZAMIL STEEL BUILDINGS DESIGN MANUAL 5. Secondary members design

PEB DIVISION

Table 5.3 - Type “G” Steel Panel

Panel Thickness mm 0.50 0.60 0.70

Weight 2 kg/m

Area 2 cm

Ix 4 cm

5.62 6.74 7.86

7.16 8.59 10.02

16.19 22.53 28.94

Top in Compression Zx-Top Zx-Bott. 3 3 cm cm 3.69 5.34 7.22

13.13 16.34 19.57

Ma kN.m 0.76 1.10 1.49

Ix 4 cm 11.28 15.02 19.16

Bottom in Compression Zx-Top Zx-Bott. 3 3 cm cm 4.51 5.76 7.06

4.09 5.54 7.17

Ma kN.m 0.85 1.14 1.46

Web Shear & Cripp. Va Pa kN kN 7.60 4.78 14.85 7.68 25.65 10.99

Allowable loads in kN/m2 Panel Thickness mm

Number of Spans 1

0.50

2

3

1

0.60

2

3

1

0.70

2

3

• • • •

Load Case

1.00

1.25

1.50

1.75

Span in meters 2.00 2.25

2.50

2.75

3.00

3.50

D+L WP WS D+L WP WS D+L WP WS D+L WP WS D+L WP WS D+L WP WS D+L WP WS D+L WP WS D+L WP WS

6.08 8.11 9.07 6.80 9.07 8.11 8.50 11.33 10.13 8.80 11.74 12.16 9.12 12.16 11.74 11.40 15.20 14.66 11.92 15.90 15.58 11.68 15.58 15.90 14.60 19.46 19.86

3.89 5.19 5.80 4.35 5.80 5.19 5.44 7.25 6.48 5.63 7.51 7.78 5.84 7.78 7.51 7.30 9.73 9.38 7.63 10.17 9.97 7.48 9.97 10.17 9.34 12.46 12.71

2.70 3.60 4.03 3.02 4.03 3.60 3.78 5.04 4.50 3.91 5.22 5.41 4.05 5.41 5.22 5.07 6.75 6.52 5.30 7.07 6.92 5.19 6.92 7.07 6.49 8.65 8.83

1.99 2.65 2.69 2.22 2.96 2.65 2.78 3.70 3.31 2.87 3.83 3.59 2.98 3.97 3.83 3.72 4.96 4.79 3.89 5.19 4.58 3.81 5.09 5.19 4.77 6.35 6.49

1.52 2.03 1.80 1.70 2.27 2.03 2.13 2.83 2.53 2.20 2.93 2.40 2.28 3.04 2.93 2.85 3.80 3.67 2.98 3.97 3.07 2.92 3.89 3.97 3.65 4.87 4.97

0.88 1.30 0.92 1.09 1.45 1.30 1.36 1.81 1.62 1.23 1.85 1.23 1.46 1.95 1.88 1.82 2.43 2.32 1.58 2.37 1.57 1.87 2.49 2.54 2.34 3.11 2.96

0.66 1.00 0.69 0.90 1.20 1.07 1.12 1.50 1.31 0.92 1.39 0.92 1.21 1.61 1.55 1.51 2.01 1.74 1.19 1.78 1.18 1.54 2.06 2.10 1.93 2.57 2.22

0.51 0.77 0.53 0.76 1.01 0.90 0.94 1.26 1.01 0.71 1.07 0.71 1.01 1.35 1.30 1.27 1.69 1.34 0.91 1.37 0.91 1.30 1.73 1.77 1.62 2.16 1.71

0.32 0.48 0.34 0.56 0.74 0.66 0.61 0.91 0.64 0.45 0.67 0.45 0.74 0.99 0.96 0.85 1.24 0.85 0.58 0.86 0.57 0.95 1.27 1.30 1.09 1.59 1.08

D + L = Dead + Live Load WP = Wind Pressure WS = Wind Pressure Material conforming to ASTM or equivalent

DM 03.10.00

1.20 1.60 1.27 1.34 1.79 1.60 1.68 2.24 2.00 1.69 2.32 1.69 1.80 2.40 2.32 2.25 3.00 2.90 2.17 3.14 2.15 2.31 3.08 3.14 2.88 3.84 3.92

(Deflection limit Span/180) (Deflection limit Span/120) (Deflection limit Span/120) 2 A792 Grade 50B (Fy = 34.5 kN/cm )

5-4

ZAMIL STEEL BUILDINGS DESIGN MANUAL 5. Secondary members design

PEB DIVISION

Table 5.4 - Type “R” Steel Panel

Panel Thickness mm 0.50 0.60 0.70

Weight 2 kg/m

Area 2 cm

Ix 4 cm

4.49 5.39 6.29

5.73 6.87 8.02

3.8 5.16 6.48

Top in Compression Zx-Top Zx-Bott. 3 3 cm cm 1.27 1.91 2.53

6.53 8.30 10.13

Ma kN.m 0.26 0.39 0.52

Ix 4 cm

Bottom in Compression Zx-Top Zx-Bott. 3 3 cm cm 1.49 1.91 2.34

1.30 1.79 2.34

Ma kN.m 0.27 0.37 0.48

Span in meters 2.00 2.25 0.41 0.28 0.61 0.43 0.36 0.25 0.54 0.43 0.72 0.57 0.69 0.55 0.68 0.53 0.90 0.71 0.67 0.47 0.55 0.39 0.83 0.58 0.48 0.34 0.74 0.58 0.99 0.78 1.04 0.82 0.93 0.73 1.23 0.97 0.91 0.64 0.69 0.49 1.04 0.73 0.62 0.44 0.96 0.76 1.28 1.01 1.39 1.05 1.20 0.92 1.60 1.26 1.17 0.82

2.50 0.21 0.31 0.18 0.35 0.46 0.44 0.39 0.58 0.34 0.28 0.42 0.25 0.47 0.63 0.59 0.53 0.79 0.47 0.35 0.53 0.32 0.61 0.82 0.76 0.67 1.00 0.60

2.75 0.16 0.23 0.14 0.29 0.38 0.33 0.29 0.44 0.26 0.21 0.32 0.19 0.39 0.52 0.45 0.40 0.60 0.35 0.27 0.40 0.24 0.51 0.68 0.57 0.50 0.75 0.45

2.23 3.01 3.89

Web Shear & Cripp. Va Pa kN kN 4.61 2.63 8.42 4.18 12.13 5.95

Allowable loads in kN/m2 Panel Thickness mm

Number of Spans 1

0.50

2

3

1

0.60

2

3

1

0.70

2

3

• • • •

Load Case D+L WP WS D+L WP WS D+L WP WS D+L WP WS D+L WP WS D+L WP WS D+L WP WS D+L WP WS D+L WP WS

1.00 2.08 2.77 2.85 2.16 2.88 2.77 2.70 3.60 3.47 3.12 4.16 3.85 2.96 3.95 4.16 3.70 4.93 5.20 4.16 5.55 4.98 3.84 5.12 5.55 4.80 6.40 6.93

D + L = Dead + Live Load WP = Wind Pressure WS = Wind Pressure Material conforming to ASTM or equivalent

DM 03.10.00

1.25 1.33 1.78 1.46 1.38 1.84 1.78 1.73 2.30 2.22 2.00 2.66 1.97 1.89 2.53 2.66 2.37 3.16 3.33 2.66 3.55 2.55 2.46 3.28 3.55 3.07 4.09 4.44

1.50 0.92 1.23 0.85 0.96 1.28 1.23 1.20 1.60 1.54 1.30 1.85 1.14 1.32 1.75 1.85 1.64 2.19 2.15 1.64 2.46 1.48 1.71 2.28 2.47 2.13 2.84 2.78

1.75 0.60 0.91 0.53 0.71 0.94 0.91 0.88 1.18 1.00 0.82 1.23 0.72 0.97 1.29 1.36 1.21 1.61 1.36 1.03 1.55 0.93 1.25 1.67 1.81 1.57 2.09 1.75

3.00 0.12 0.18 0.11 0.24 0.32 0.25 0.23 0.34 0.20 0.16 0.24 0.14 0.33 0.44 0.34 0.31 0.46 0.27 0.20 0.31 0.18 0.43 0.57 0.44 0.39 0.58 0.35

3.50 0.08 0.11 0.07 0.18 0.24 0.16 0.14 0.21 0.13 0.10 0.15 0.09 0.24 0.32 0.22 0.19 0.29 0.17 0.13 0.19 0.12 0.31 0.42 0.28 0.24 0.36 0.22

(Deflection limit Span/180) (Deflection limit Span/120) (Deflection limit Span/120) 2 A792 Grade 50B (Fy = 34.5 kN/cm )

5-5

ZAMIL STEEL BUILDINGS DESIGN MANUAL 5. Secondary members design

PEB DIVISION

Table 5.5 - Type “S” Steel Panel

Panel Thickness mm 0.50 0.60 0.70

Top in Compression Zx-Top Zx-Bott. cm3 cm3

Weight kg/m2

Area cm2

Ix cm4

4.78 5.74 6.70

6.09 7.31 8.54

5.76 8.07 10.16

1.93 2.67 3.62

7.38 9.46 11.35

Ma kN.m 0.40 0.55 0.75

Ix cm4 5.52 7.33 9.20

Bottom in Compression Zx-Top Zx-Bott. cm3 cm3 2.47 3.15 3.84

3.89 5.34 7.00

Ma kN.m 0.51 0.65 0.79

2.50 0.32 0.49 0.47 0.65 0.87 0.68 0.61 0.92 0.85 0.45 0.68 0.62 0.83 1.11 0.94 0.86 1.29 1.17 0.57 0.86 0.78 1.01 1.34 1.28 1.08 1.62 1.47

2.75 0.24 0.37 0.35 0.54 0.72 0.56 0.46 0.69 0.66 0.34 0.51 0.47 0.69 0.91 0.77 0.64 0.97 0.88 0.43 0.64 0.58 0.84 1.11 1.06 0.81 1.22 1.10

Web Shear & Cripp. Va Pa kN kN 4.97 3.39 9.71 5.43 15.83 7.76

Allowable loads in kN/m2 Panel Number Thickness of mm Spans 1

0.50

2

3

1

0.60

2

3

1

0.70

2

3

• • • •

Load Case D+L WP WS D+L WP WS D+L WP WS D+L WP WS D+L WP WS D+L WP WS D+L WP WS D+L WP WS D+L WP WS

1.00 3.20 4.26 5.43 2.71 3.59 4.26 3.08 4.10 5.33 4.40 5.85 6.92 4.34 5.76 5.85 4.94 6.57 7.33 6.00 7.98 8.41 6.21 8.23 7.98 7.06 9.39 10.00

D + L = Dead + Live Load WP = Wind Pressure WS = Wind Pressure Material conforming to ASTM or equivalent

DM 03.10.00

1.25 2.05 2.72 3.47 2.17 2.87 2.72 2.47 3.28 3.41 2.82 3.75 4.43 3.33 4.43 3.75 3.95 5.26 4.69 3.84 5.11 5.38 4.04 5.38 5.11 5.06 6.74 6.40

1.50 1.42 1.89 2.16 1.81 2.40 1.89 2.06 2.73 2.37 1.96 2.60 2.87 2.31 3.07 2.60 2.89 3.85 3.26 2.65 3.55 3.60 2.81 3.74 3.55 3.51 4.68 4.44

1.75 0.95 1.39 1.36 1.33 1.77 1.39 1.67 2.22 1.74 1.33 1.91 1.81 1.70 2.26 1.91 2.12 2.83 2.39 1.67 2.50 2.27 2.06 2.74 2.61 2.58 3.44 3.26

Span in meters 2.00 2.25 0.63 0.44 0.95 0.67 0.91 0.64 1.02 0.81 1.36 1.07 1.06 0.84 1.20 0.84 1.70 1.26 1.33 1.05 0.89 0.62 1.33 0.94 1.21 0.85 1.30 1.03 1.73 1.37 1.46 1.16 1.63 1.18 2.17 1.71 1.83 1.45 1.12 0.78 1.68 1.18 1.52 1.07 1.58 1.25 2.10 1.66 2.00 1.58 1.98 1.48 2.63 2.08 2.50 1.97

3.00 0.19 0.28 0.27 0.45 0.60 0.47 0.35 0.53 0.51 0.26 0.39 0.36 0.58 0.77 0.65 0.50 0.74 0.68 0.33 0.50 0.45 0.70 0.93 0.89 0.62 0.94 0.85

3.50 0.12 0.18 0.17 0.28 0.43 0.35 0.22 0.33 0.32 0.17 0.25 0.23 0.40 0.56 0.48 0.31 0.47 0.43 0.21 0.31 0.28 0.50 0.69 0.65 0.39 0.59 0.53

(Deflection limit Span/180) (Deflection limit Span/120) (Deflection limit Span/120) 2 A792 Grade 50B (Fy = 34.5 kN/cm )

5-6

ZAMIL STEEL BUILDINGS DESIGN MANUAL 5. Secondary members design

PEB DIVISION

Table 5.6 - Type “K” Steel Panel

Panel Thickness mm 0.50 0.60 0.70

Weight kg/m2 5.32 6.38 7.45

Area cm2 6.10 7.32 8.54

Ix cm4 23.42 30.52 37.84

Top in Compression Zx-Top Zx-Bott. cm3 cm3 7.00 9.26 10.01 11.68 12.18 14.12

Ma kN.m 1.45 2.07 2.52

Ix cm4 23.42 30.52 37.84

Bottom in Compression Zx-Top Zx-Bott. cm3 cm3 7.00 9.26 10.01 11.68 12.18 14.12

Ma kN.m 1.45 2.07 2.52

Web Shear & Cripp. Va Pa kN kN 4.55 6.34 8.88 9.97 15.35 13.96

Allowable loads in kN/m2 Panel Number Thickness of mm Spans 1

0.50

2

3

1

0.60

2

3

1

0.70

2

3

• • • •

Load Case D+L WP WS D+L WP WS D+L WP WS D+L WP WS D+L WP WS D+L WP WS D+L WP WS D+L WP WS D+L WP WS

1.00 9.10 12.10 12.10 5.07 6.72 9.65 5.77 7.67 10.06 16.56 22.02 22.02 7.98 10.57 18.83 9.07 12.06 19.62 20.16 26.81 26.81 11.17 14.80 26.81 12.70 16.89 33.59

D + L = Dead + Live Load WP = Wind Pressure WS = Wind Pressure Material conforming to ASTM or equivalent

DM 03.10.00

1.25 7.28 9.68 9.68 4.06 5.38 7.72 4.62 6.14 8.04 10.60 14.10 14.10 6.38 8.45 14.10 7.26 9.65 15.70 12.90 17.16 17.16 8.93 11.84 17.16 10.16 13.51 21.50

1.50 5.16 6.86 6.86 3.38 4.48 6.43 3.85 5.11 6.70 7.36 9.79 9.79 5.32 7.05 9.79 6.05 8.04 12.26 8.96 11.92 11.92 7.45 9.87 11.92 8.47 11.26 14.93

1.75 3.79 5.04 5.04 2.90 3.84 5.04 3.30 4.38 5.75 5.01 7.19 7.19 4.56 6.04 7.19 5.18 6.89 9.01 6.21 8.76 8.76 6.38 8.46 8.76 7.26 9.65 10.97

Span in meters 2.00 2.25 2.58 1.81 3.86 2.71 3.86 2.71 2.54 2.25 3.36 2.99 3.86 3.05 2.88 2.56 3.84 3.41 4.83 3.82 3.36 2.36 5.04 3.54 5.04 3.54 3.99 3.27 5.28 4.35 5.51 4.35 4.54 4.03 6.03 5.36 6.90 5.45 4.16 2.92 6.24 4.39 6.24 4.39 5.04 3.98 6.70 5.30 6.70 5.30 6.30 4.98 8.40 6.64 8.40 6.64

2.50 1.32 1.98 1.98 1.86 2.47 2.47 2.31 3.07 3.09 1.72 2.58 2.58 2.65 3.52 3.52 3.24 4.41 4.41 2.13 3.20 3.20 3.23 4.29 4.29 4.02 5.37 5.37

2.75 0.99 1.49 1.49 1.53 2.04 2.04 1.87 2.56 2.56 1.29 1.94 1.94 2.19 2.91 2.91 2.44 3.65 3.65 1.60 2.40 2.40 2.67 3.55 3.55 3.02 4.44 4.44

3.00 0.76 1.14 1.14 1.29 1.71 1.71 1.44 2.15 2.15 0.99 1.49 1.49 1.84 2.45 2.45 1.88 2.81 2.81 1.23 1.85 1.85 2.24 2.98 2.98 2.33 3.49 3.49

3.50 0.48 0.72 0.72 0.95 1.26 1.26 0.91 1.36 1.36 0.63 0.94 0.94 1.35 1.80 1.80 1.18 1.77 1.77 0.78 1.16 1.16 1.65 2.19 2.19 1.47 2.20 2.20

(Deflection limit Span/180) (Deflection limit Span/120) (Deflection limit Span/120) 2 A792 Grade 50B (Fy = 34.5 kN/cm )

5-7

ZAMIL STEEL BUILDINGS DESIGN MANUAL 5. Secondary members design

PEB DIVISION

5.1.1.2. Aluminum Panels Aluminum panels have base material of aluminum and are available in one skin thickness of 0.7mm only. Following are the load tables for available types ‘A’, ‘R’ and ‘S’ panel. Table 5.7 - Type “A” Aluminum Panel

Panel Thickness mm 0.70

Weight kg/m2

Area cm2

Ix cm4

2.47

8.90

6.15

Top in Compression Zx-Top Zx-Bott. cm3 cm3 3.64

7.61

Ma kN.m 0.35

Ix cm4

Bottom in Compression Zx-Top Zx-Bott. cm3 cm3

5.61

3.44

5.55

Ma kN.m 0.33

Web Shear & Cripp. Va Pa kN kN 11.91 6.27

Allowable loads in kN/m2 Panel Thickness mm

Number of Spans 1

0.70

2

3

Note:

D+L =

Load Case

1.00

1.25

1.50

1.75

Span in meters 2.00 2.25

2.50

2.75

3.00

3.50

D+L WP WS D+L WP WS D+L WP WS

1.81 2.71 2.47 2.64 3.52 3.73 3.30 4.40 4.67

0.93 1.39 1.27 1.69 2.25 2.39 1.75 2.62 2.39

0.54 0.80 0.73 1.17 1.56 1.66 1.01 1.52 1.38

0.34 0.51 0.46 0.81 1.15 1.11 0.64 0.96 0.87

0.23 0.34 0.31 0.55 0.82 0.75 0.43 0.64 0.58

0.12 0.17 0.16 0.28 0.42 0.38 0.22 0.33 0.30

0.09 0.13 0.12 0.21 0.31 0.29 0.16 0.25 0.22

0.07 0.10 0.09 0.16 0.24 0.22 0.13 0.19 0.17

0.04 0.06 0.06 0.10 0.15 0.14 0.08 0.12 0.11

Dead + Live Load

0.16 0.24 0.22 0.38 0.57 0.52 0.30 0.45 0.41

(Deflection limit Span/180)

WP

=

Wind Pressure

(Deflection limit Span/120)

WS

=

Wind Pressure

(Deflection limit Span/120) 2

Material conforming to Alloy Type AA 300 3H26 (Fy = 16.15 kN/cm ) or equivalent

DM 03.10.00

5-8

ZAMIL STEEL BUILDINGS DESIGN MANUAL 5. Secondary members design

PEB DIVISION

Table 5.8 - Type “R” Aluminum Panel

Panel Thickness mm 0.70

Weight kg/m2

Area cm2

Ix cm4

2.22

8.01

6.48

Top in Compression Zx-Top Zx-Bott. cm3 cm3 2.53

10.13

Ma kN.m 0.24

Ix cm4 3.89

Bottom in Compression Zx-Top Zx-Bott. cm3 cm3 2.34

2.34

Ma kN.m 0.22

Web Shear & Cripp. Va Pa kN kN 5.68 2.78

Allowable loads in kN/m2 Panel Thickness mm

Number of Spans 1

0.70

2

3

Note:

D+L =

Load Case

1.00

1.25

1.50

1.75

Span in meters 2.00 2.25

2.50

2.75

3.00

3.50

D+L WP WS D+L WP WS D+L WP WS

1.91 2.56 1.72 1.76 2.35 2.56 2.20 2.93 3.20

0.98 1.46 0.88 1.13 1.50 1.64 1.41 1.88 1.66

0.56 0.85 0.51 0.78 1.04 1.14 0.98 1.30 0.96

0.36 0.53 0.32 0.57 0.77 0.77 0.67 0.96 0.60

0.24 0.36 0.21 0.44 0.59 0.52 0.45 0.67 0.41

0.12 0.18 0.11 0.28 0.38 0.26 0.23 0.35 0.21

0.09 0.14 0.08 0.22 0.31 0.20 0.17 0.26 0.16

0.07 0.11 0.06 0.17 0.26 0.15 0.13 0.20 0.12

0.04 0.07 0.04 0.11 0.16 0.10 0.08 0.13 0.08

Dead + Live Load

0.17 0.25 0.15 0.35 0.46 0.36 0.32 0.47 0.28

(Deflection limit Span/180)

WP

=

Wind Pressure

(Deflection limit Span/120)

WS

=

Wind Pressure

(Deflection limit Span/120) 2

Material conforming to Alloy Type AA 300 3H26 (Fy = 16.15 kN/cm ) or equivalent

DM 03.10.00

5-9

ZAMIL STEEL BUILDINGS DESIGN MANUAL 5. Secondary members design

PEB DIVISION

Table 5.9 - Type “S”- Aluminum panel Panel Thickness mm 0.70

Weight 2 kg/m 2.34

Area 2 cm 8.54

Ix 4 cm 9.74

Top in Compression Zx-Top Zx-Bott. 3 3 cm cm 3.23 11.41

Ma kN.m 0.31

Ix 4 cm 8.70

Bottom in Compression Zx-Top Zx-Bott. Ma 3 3 cm cm kN.m 3.75 6.32 0.36

Web Shear & Cripp. Va Pa kN kN 5.51 9.10

Allowable loads in kN/m2 Panel Number Thickness of mm Spans 1

0.70

2

3

Note:

D+L =

Load Case D+L WP WS D+L WP WS D+L WP WS

1.00 2.48 3.30 3.83 2.88 3.83 3.30 3.60 4.80 4.13

Dead + Live Load

1.25 1.59 2.11 2.45 1.84 2.45 2.11 2.30 3.07 2.64

1.50 1.10 1.47 1.70 1.28 1.70 1.47 1.60 2.13 1.84

1.75 0.81 1.08 1.25 0.94 1.25 1.08 1.18 1.57 1.35

Span in meters 2.00 2.25 0.62 0.49 0.82 0.65 0.96 0.76 0.72 0.57 0.96 0.76 0.82 0.65 0.90 0.71 1.20 0.95 1.03 0.82

2.50 0.40 0.53 0.61 0.46 0.61 0.53 0.58 0.77 0.66

2.75 0.33 0.44 0.51 0.38 0.51 0.44 0.48 0.63 0.55

3.00 0.28 0.37 0.43 0.32 0.43 0.37 0.40 0.53 0.46

3.50 0.20 0.27 0.27 0.24 0.31 0.27 0.29 0.39 0.34

(Deflection limit Span/180)

WP

=

Wind Pressure

(Deflection limit Span/120)

WS

=

Wind Pressure

(Deflection limit Span/120) 2

Material conforming to Alloy Type AA 300 3H26 (Fy = 16.15 kN/cm ) or equivalent

5.1.2. Tempcon Panels The Tempcon insulated panels are composed of two single skin panels with polyurethane foam in between. Three types are available. 1. High-Rib (TCSP) with overall panel thickness of 75, 85 and 100 mm and metal thicknesses of 0.5 mm and 0.7mm available with steel and aluminum single skin panels. 2. Low-Rib (TCTP) with overall panel thickness of 60 mm. and metal thicknesses of 0.5 mm and 0.7mm available with steel and aluminum single skin panels. 3. Modified (TCMP) with overall panel thickness of 60,75,85 and 100 mm thickness 0.5mm available only with steel single skin panels . Usage: These panels are intended for use as thermally efficient roof and wall claddings for buildings. Properties and allowable loads are shown on Tables 5.10 to 5.18

DM 03.10.00

5-10

ZAMIL STEEL BUILDINGS DESIGN MANUAL 5. Secondary members design

PEB DIVISION

5.1.2.1. Steel Tempcon Panels Table 5.10 - Tempcon High Rib (TCSP) Insulated Steel Panel Total depth 100mm

Section Properties Skin Thickness (mm)

Area cm2

Ix cm4

Top in Compression Zx-Top Zx-Bott. cm3 cm3

Ma kN.m

Ix cm4

Bottom in Compression Zx-Top Zx-Bott. cm3 cm3

Ma kN.m

Web Shear & Cripp. Va Pa kN kN

Exterior

Interior

Weight kg/m2

0.7

0.7

15.18

16.03

166.33

21.07

47.54

4.35

165.93

28.38

31.16

5.86

4.75

10.99

0.7

0.5

13.50

13.89

136.33

19.84

32.03

4.10

129.94

25.11

21.09

4.36

4.75

8.59

0.5

0.5

11.58

11.46

97.94

12.22

30.84

2.52

110.26

18.89

20.63

3.90

4.63

8.59

Span in meters 2.75 3.46

3.00 3.17

3.25 2.93

3.50 2.72

3.75 2.48

4.00 2.18

Allowable Load Table [ kN/m2 ] Skin Thickness (mm)

Number of Spans 1

Ext. 0.7 2

Load Case D+L

1.50 6.34

1.75 5.43

2.00 4.75

2.25 4.23

2.50 3.80

WP

8.43

7.23

6.32

5.62

5.06

4.60

4.22

3.89

3.61

3.29

2.90

WS D+L

8.84 5.32

7.58 4.56

6.63 3.99

5.90 3.55

5.31 3.19

4.82 2.90

4.42 2.66

4.08 2.46

3.79 2.28

3.54 2.13

3.32 1.99

WP

7.08

6.06

5.31

4.72

4.25

3.86

3.54

3.27

3.03

2.83

2.65

WS D+L

6.74 5.54

5.78 4.75

5.06 4.16

4.50 3.69

4.05 3.32

3.68 3.02

3.37 2.77

3.11 2.56

2.89 2.37

2.70 2.22

2.53 2.08

3

WP WS D+L

7.37 7.03 6.34

6.32 6.02 5.43

5.53 5.27 4.75

4.91 4.68 4.23

4.42 4.22 3.80

4.02 3.83 3.46

3.68 3.51 3.17

3.40 3.24 2.93

3.16 3.01 2.68

2.95 2.81 2.24

2.76 2.63 1.85

1

WP WS

8.43 8.84

7.23 7.58

6.32 6.63

5.62 5.90

5.06 5.31

4.60 4.82

4.22 4.42

3.89 4.08

3.56 3.78

3.10 3.20

2.73 2.64

D+L

4.58

3.93

3.44

3.05

2.75

2.50

2.29

2.11

1.96

1.83

1.72

WP WS

6.09 6.74

5.22 5.78

4.57 5.06

4.06 4.50

3.66 4.05

3.32 3.68

3.05 3.37

2.81 3.11

2.61 2.89

2.44 2.70

2.28 2.53

D+L

5.21

4.46

3.90

3.47

3.12

2.84

2.60

2.40

2.23

2.08

1.95

WP

6.92

5.93

5.19

4.62

4.15

3.78

3.46

3.20

2.97

2.77

2.60

WS D+L

7.03 6.17

6.02 5.29

5.27 4.63

4.68 3.99

4.22 3.23

3.83 2.67

3.51 2.24

3.24 1.91

3.01 1.65

2.81 1.44

2.63 1.26

Int. 0.7

Ext. 0.7 2 Int. 0.5 3

1 Ext. 0.5 2 Int. 0.5 3

WP

8.20

7.03

6.15

5.31

4.30

3.55

2.98

2.54

2.19

1.91

1.68

WS D+L

8.57 4.58

7.35 3.93

6.43 3.44

5.71 3.05

5.14 2.75

4.67 2.50

4.29 2.29

3.93 2.11

3.34 1.96

2.72 1.83

2.24 1.72

WP

6.09

5.22

4.57

4.06

3.66

3.32

3.05

2.81

2.61

2.44

2.28

WS D+L

6.56 5.21

5.63 4.46

4.92 3.90

4.38 3.47

3.94 3.12

3.55 2.84

2.98 2.60

2.54 2.39

2.19 2.06

1.91 1.80

1.68 1.58

WP

6.92

5.93

5.19

4.62

4.15

3.78

3.46

3.18

2.74

2.39

2.10

WS

6.84

5.86

5.13

4.56

4.10

3.73

3.42

3.16

2.74

2.39

2.10

• D + L = Dead + Live Load (Deflection limit Span/180) • WP = Wind Pressure (Deflection limit Span/120) • WS = Wind Pressure (Deflection limit Span/120) • Material conforming to ASTM A792 Grade 50B (Fy = 34.5 kN/cm2) or equivalent

DM 03.10.00

5-11

ZAMIL STEEL BUILDINGS DESIGN MANUAL 5. Secondary members design

PEB DIVISION

Table 5.11 - Tempcon High Rib (TCSP) Insulated Steel Panel Total depth 85mm

Section Properties Skin Thickness (mm)

Area cm2

Ix cm4

Top in Compression Zx-Top Zx-Bott. cm3 cm3

Ma kN.m

Ix cm4

Bottom in Compression Zx-Top Zx-Bott. cm3 cm3

Ma kN.m

Web Shear & Cripp. Va Pa kN kN

Exterior

Interior

Weight kg/m2

0.7

0.7

14.66

16.03

110.00

16.13

39.03

3.33

112.76

21.37

27.26

4.42

3.90

0.7

0.5

12.98

13.89

90.60

15.09

26.45

3.12

89.09

18.85

18.50

3.82

3.90

8.59

0.5

0.5

11.06

11.46

64.39

9.25

25.13

1.91

74.69

14.20

17.93

2.93

3.77

8.59

10.99

Allowable Load Table [ kN/m2 ] Skin Thickness (mm)

Number of Spans 1

Ext. 0.7 2 Int. 0.7 3

1 Ext. 0.7 2 Int. 0.5 3

1 Ext. 0.5 2 Int. 0.5 3

1.75 4.46

2.00 3.90

2.25 3.47

2.50 3.12

Span in meters 2.75 2.84

3.00 2.60

3.25 2.40

3.50 2.18

3.75 1.81

4.00 1.49

6.92

5.93

5.19

4.61

4.15

3.78

3.46

3.19

2.89

2.52

2.22

7.29

6.25

5.47

4.86

4.38

3.98

3.65

3.37

3.13

2.78

2.29

D+L

4.39

3.76

3.29

2.92

2.63

2.39

2.19

2.02

1.88

1.75

1.64

WP

5.83

5.00

4.38

3.89

3.50

3.18

2.92

2.69

2.50

2.33

2.19

WS

5.54

4.75

4.15

3.69

3.32

3.02

2.77

2.56

2.37

2.21

2.08

D+L

4.57

3.92

3.43

3.05

2.74

2.49

2.28

2.11

1.96

1.83

1.71

WP

6.08

5.21

4.56

4.05

3.65

3.31

3.04

2.80

2.60

2.43

2.28

WS

5.77

4.94

4.33

3.85

3.46

3.15

2.88

2.66

2.47

2.31

2.16

D+L

5.20

4.46

3.90

3.47

3.12

2.84

2.60

2.29

1.83

1.49

1.23

WP

6.92

5.93

5.19

4.61

4.15

3.78

3.46

3.14

2.71

2.23

1.84

WS

7.29

6.25

5.47

4.86

4.38

3.98

3.65

3.37

2.70

2.19

1.81

D+L

4.39

3.76

3.29

2.92

2.63

2.39

2.19

2.02

1.88

1.75

1.64

WP

5.83

5.00

4.38

3.89

3.50

3.18

2.92

2.69

2.50

2.33

2.19

WS

5.54

4.75

4.15

3.69

3.32

3.02

2.77

2.56

2.37

2.21

2.07

D+L

4.57

3.92

3.43

3.05

2.74

2.49

2.28

2.11

1.96

1.83

1.71

WP

6.08

5.21

4.56

4.05

3.65

3.31

3.04

2.80

2.60

2.43

2.28

WS

5.77

4.94

4.33

3.85

3.46

3.15

2.88

2.66

2.47

2.31

2.16

D+L

5.03

4.31

3.77

3.02

2.45

2.02

1.70

1.45

1.25

1.06

0.87

WP

6.68

5.73

5.01

4.02

3.25

2.69

2.26

1.92

1.66

1.45

1.27

WS

7.10

6.09

5.33

4.73

4.26

3.87

3.47

2.83

2.26

1.84

1.52

D+L

4.27

3.66

3.20

2.85

2.56

2.33

2.14

1.97

1.83

1.67

1.47

WP

5.68

4.87

4.26

3.79

3.41

3.10

2.84

2.62

2.43

2.22

1.95

WS D+L

5.35 4.45

4.58 3.81

4.01 3.34

3.57 2.97

3.21 2.67

2.69 2.43

2.26 2.12

1.92 1.81

1.66 1.56

1.45 1.36

1.27 1.19

WP

5.92

5.07

4.44

3.94

3.55

3.23

2.82

2.41

2.07

1.81

1.59

WS

5.57

4.77

4.18

3.71

3.34

3.04

2.79

2.41

2.07

1.81

1.59

Load Case D+L

1.50 5.20

WP WS

• D + L = Dead + Live Load (Deflection limit Span/180) • WP = Wind Pressure (Deflection limit Span/120) • WS = Wind Pressure (Deflection limit Span/120) • Material conforming to ASTM A792 Grade 50B (Fy = 34.5 kN/cm2) or equivalent

DM 03.10.00

5-12

ZAMIL STEEL BUILDINGS DESIGN MANUAL 5. Secondary members design

PEB DIVISION

Table 5.12 - Tempcon High Rib (TCSP) Insulated Steel Panel Total depth 75mm

Section Properties Skin Thickness (mm)

Area cm2

Ix cm4

Top in Compression Zx-Top Zx-Bott. cm3 cm3

Ma kN.m

Ix cm4

Bottom in Compression Zx-Top Zx-Bott. cm3 cm3

Ma kN.m

Web Shear & Cripp. Va Pa kN kN

Exterior

Interior

Weight kg/m2

0.7

0.7

14.31

16.03

79.23

13.03

33.47

2.69

83.46

17.08

24.97

3.53

3.35

0.7

0.5

12.63

13.89

65.64

12.13

22.84

2.51

66.14

15.01

16.80

3.10

3.35

8.59

0.5

0.5

10.71

11.46

46.04

7.34

21.44

1.52

54.80

11.29

16.11

2.33

3.22

8.59

10.99

Allowable Load Table [ kN/m2 ] Skin Thickness (mm)

Number of Spans 1

Ext. 0.7 2 Int. 0.7 3

1 Ext. 0.7 2 Int. 0.5 3

1 Ext. 0.5 2 Int. 0.5 3

1.75 3.83

2.00 3.35

2.25 2.98

2.50 2.68

Span in meters 2.75 2.43

3.00 2.23

3.25 2.00

3.50 1.60

3.75 1.30

4.00 1.07

5.94

5.09

4.45

3.96

3.56

3.24

2.97

2.71

2.34

1.95

1.61

6.28

5.39

4.71

4.19

3.77

3.43

3.14

2.90

2.53

2.06

1.69

D+L

3.78

3.24

2.83

2.52

2.27

2.06

1.89

1.74

1.62

1.51

1.42

WP

5.03

4.31

3.77

3.35

3.02

2.74

2.51

2.32

2.15

2.01

1.89

WS

4.75

4.07

3.56

3.17

2.85

2.59

2.37

2.19

2.04

1.90

1.78

D+L

3.94

3.37

2.95

2.62

2.36

2.15

1.97

1.82

1.69

1.57

1.48

WP

5.24

4.49

3.93

3.49

3.14

2.86

2.62

2.42

2.24

2.09

1.96

WS

4.95

4.24

3.71

3.30

2.97

2.70

2.47

2.28

2.12

1.98

1.85

D+L

4.46

3.83

3.35

2.98

2.68

2.43

2.11

1.66

1.33

1.08

0.89

WP

5.94

5.09

4.45

3.96

3.56

3.24

2.96

2.48

1.99

1.62

1.33

WS

6.28

5.39

4.71

4.19

3.77

3.43

3.14

2.50

2.00

1.63

1.34

D+L

3.78

3.24

2.83

2.52

2.27

2.06

1.89

1.74

1.62

1.51

1.42

WP

5.03

4.31

3.77

3.35

3.02

2.74

2.51

2.32

2.15

2.01

1.89

WS

4.75

4.07

3.56

3.17

2.85

2.59

2.37

2.19

2.04

1.90

1.67

D+L

3.94

3.37

2.95

2.62

2.36

2.15

1.97

1.82

1.69

1.57

1.48

WP

5.24

4.49

3.93

3.49

3.14

2.86

2.62

2.42

2.24

2.09

1.96

WS

4.95

4.24

3.71

3.30

2.97

2.70

2.47

2.28

2.12

1.98

1.85

D+L

4.29

3.68

3.03

2.40

1.94

1.60

1.35

1.15

0.93

0.76

0.62

WP

5.70

4.89

4.03

3.19

2.58

2.13

1.79

1.53

1.32

1.13

0.93

WS

6.16

5.28

4.62

4.11

3.70

3.28

2.64

2.07

1.66

1.35

1.11

D+L

3.71

3.18

2.78

2.47

2.22

2.02

1.85

1.71

1.52

1.33

1.17

WP

4.93

4.23

3.70

3.29

2.96

2.69

2.46

2.28

2.03

1.76

1.55

WS

4.56

3.91

3.42

3.04

2.58

2.13

1.79

1.53

1.32

1.15

1.01

D+L

3.86

3.31

2.90

2.57

2.32

2.00

1.68

1.44

1.24

1.08

0.95

WP

5.14

4.40

3.85

3.42

3.08

2.67

2.24

1.91

1.65

1.43

1.26

WS

4.75

4.07

3.56

3.17

2.85

2.59

2.24

1.91

1.65

1.43

1.26

Load Case D+L

1.50 4.46

WP WS

• D + L = Dead + Live Load (Deflection limit Span/180) • WP = Wind Pressure (Deflection limit Span/120) • WS = Wind Pressure (Deflection limit Span/120) • Material conforming to ASTM A792 Grade 50B (Fy = 34.5 kN/cm2) or equivalent

DM 03.10.00

5-13

ZAMIL STEEL BUILDINGS DESIGN MANUAL 5. Secondary members design

PEB DIVISION

Table 5.13 - Tempcon Low Rib (TCTP) Insulated Steel Panel Total depth 60mm

Section Properties Skin Thickness (mm)

Area cm2

Ix cm4

Top in Compression Zx-Top Zx-Bott. cm3 cm3

Ma kN.m

Ix cm4

Bottom in Compression Zx-Top Zx-Bott. cm3 cm3

Ma kN.m

Web Shear & Cripp. Va Pa kN kN

Exterior

Interior

Weight kg/m2

0.7

0.7

13.88

15.01

95.69

23.64

36.00

4.88

95.69

36.00

23.64

4.88

3.60

10.99

0.7

0.5

12.20

12.86

78.34

23.64

24.00

4.88

74.40

36.00

15.60

3.22

3.60

8.59

0.5

0.5

10.52

10.72

63.47

15.60

24.00

3.22

63.47

24.00

15.60

3.22

3.60

8.59

Allowable Load Table [ kN/m2 ] Skin Thickness (mm)

Number of Spans 1

Ext. 0.7 2 Int. 0.7 3

1 Ext. 0.7 2 Int. 0.5 3

1 Ext. 0.5 2 Int. 0.5 3

Load Case D+L

1.50 4.80

1.75 4.11

2.00 3.60

2.25 3.20

2.50 2.88

Span in meters 2.75 2.62

3.00 2.40

3.25 2.22

3.50 1.93

3.75 1.57

4.00 1.30

WP

6.38

5.47

4.79

4.26

3.83

3.48

3.19

2.95

2.74

2.36

1.94

WS D+L

6.38 3.84

5.47 3.29

4.79 2.88

4.26 2.56

3.83 2.30

3.48 2.09

3.19 1.92

2.95 1.77

2.74 1.65

2.36 1.54

1.94 1.44

WP

5.11

4.38

3.83

3.40

3.06

2.79

2.55

2.36

2.19

2.04

1.92

WS

5.11

4.38

3.83

3.40

3.06

2.79

2.55

2.36

2.19

2.04

1.92

D+L

4.00

3.43

3.00

2.67

2.40

2.18

2.00

1.85

1.71

1.60

1.50

WP

5.32

4.56

3.99

3.55

3.19

2.90

2.66

2.46

2.28

2.13

2.00

WS

5.32

4.56

3.99

3.55

3.19

2.90

2.66

2.46

2.28

2.13

2.00

D+L

4.80

4.11

3.60

3.20

2.88

2.62

2.40

1.98

1.58

1.29

1.06

WP

6.38

5.47

4.79

4.26

3.83

3.48

3.19

2.95

2.37

1.93

1.59

WS

6.38

5.47

4.79

4.26

3.83

3.48

3.19

2.82

2.25

1.83

1.51

D+L

3.84

3.29

2.88

2.56

2.30

2.09

1.92

1.77

1.65

1.54

1.44

WP

5.11

4.38

3.83

3.40

3.06

2.79

2.55

2.36

2.19

2.04

1.92

WS D+L

5.11 4.00

4.38 3.43

3.83 3.00

3.40 2.67

3.06 2.40

2.79 2.18

2.55 2.00

2.36 1.85

2.19 1.71

2.04 1.60

1.92 1.50

WP

5.32

4.56

3.99

3.55

3.19

2.90

2.66

2.46

2.28

2.13

2.00

WS

5.32

4.56

3.99

3.55

3.19

2.90

2.66

2.46

2.28

2.13

2.00

D+L

4.80

4.11

3.60

3.20

2.88

2.62

2.04

1.60

1.28

1.04

0.86

WP

6.38

5.47

4.79

4.26

3.83

3.48

3.05

2.40

1.92

1.56

1.29

WS

6.38

5.47

4.79

4.26

3.83

3.48

3.05

2.40

1.92

1.56

1.29

D+L

3.84

3.29

2.88

2.56

2.30

2.09

1.92

1.77

1.65

1.54

1.44

WP

5.11

4.38

3.83

3.40

3.06

2.79

2.55

2.36

2.19

2.04

1.92

WS

5.11

4.38

3.83

3.40

3.06

2.79

2.55

2.36

2.19

2.04

1.92

D+L

4.00

3.43

3.00

2.67

2.40

2.18

2.00

1.85

1.71

1.60

1.50

WP

5.32

4.56

3.99

3.55

3.19

2.90

2.66

2.46

2.28

2.13

2.00

WS

5.32

4.56

3.99

3.55

3.19

2.90

2.66

2.46

2.28

2.13

2.00

• D + L = Dead + Live Load (Deflection limit Span/180) • WP = Wind Pressure (Deflection limit Span/120) • WS = Wind Pressure (Deflection limit Span/120) • Material conforming to ASTM A792 Grade 50B (Fy = 34.5 kN/cm2) or equivalent

DM 03.10.00

5-14

ZAMIL STEEL BUILDINGS DESIGN MANUAL 5. Secondary members design

PEB DIVISION

Table 5.14 - Tempcon Modified (TCMP) Insulated Steel Panel

Panel Section Properties TCMP PANEL Thickness Weight T (mm) 60 75 85 100

2

kg/m 11.66 12.18 12.53 13.06

Top in Compression

Bottom in Compression

Web Shear & Cripp.

Exterior Skin Thk (mm)

Ix

Zx-Top

Zx-Bott.

Ma

Ix

Zx-Top

Zx-Bott.

Ma

Va

Pa

cm4

cm3

cm3

kN.m

cm4

cm3

cm3

kN.m

kN

kN

0.5

5.76

1.93

7.38

0.40

5.52

2.47

3.89

0.51

4.97

3.39

Span in meters 2.00 2.25 0.63 0.44 0.95 0.67 0.91 0.64 1.02 0.81 1.36 1.07 1.06 0.84 1.20 0.84 1.70 1.26 1.33 1.05

2.50 0.32 0.49 0.47 0.65 0.87 0.68 0.61 0.92 0.85

2.75 0.24 0.37 0.35 0.54 0.72 0.56 0.46 0.69 0.66

3.00 0.19 0.28 0.27 0.45 0.60 0.47 0.35 0.53 0.51

3.50 0.12 0.18 0.17 0.28 0.43 0.35 0.22 0.33 0.32

Panel Load Table [ kN/m2 ] Panel Number Thickness of mm Spans 1

0.50

2

3

Load Case D+L WP WS D+L WP WS D+L WP WS

1.00 3.20 4.26 5.43 2.71 3.59 4.26 3.08 4.10 5.33

1.25 2.05 2.72 3.47 2.17 2.87 2.72 2.47 3.28 3.41

1.50 1.42 1.89 2.16 1.81 2.40 1.89 2.06 2.73 2.37

1.75 0.95 1.39 1.36 1.33 1.77 1.39 1.67 2.22 1.74

• D + L = Dead + Live Load

(Deflection limit Span/180) • WP = Wind Pressure (Deflection limit Span/120) • WS = Wind Pressure (Deflection limit Span/120) • Material conforming to ASTM A792 Grade 50B (Fy = 34.5 kN/cm2) or equivalent

DM 03.10.00

5-15

ZAMIL STEEL BUILDINGS DESIGN MANUAL 5. Secondary members design

PEB DIVISION

5.1.2.2. Aluminum Tempcon Panels Table 5.15 - Tempcon High Rib (TCSP) Insulated Aluminum Panel Total depth 100mm

Section Properties Skin Thickness (mm)

Area cm2

Ix cm4

Top in Compression Zx-Top Zx-Bott. cm3 cm3

Ma kN.m

Ix cm4

Bottom in Compression Zx-Top Zx-Bott. cm3 cm3

Ma kN.m

Web Shear & Cripp. Va Pa kN kN

Exterior

Interior

Weight kg/m2

0.7

0.7

6.99

16.03

160.27

19.89

46.99

1.92

178.02

29.43

35.90

2.85

4.70

9.07

0.7

0.5

6.40

13.89

131.78

18.72

31.65

1.81

132.38

25.39

21.75

2.10

4.70

7.45

0.5

0.5

5.73

11.46

95.75

11.95

30.32

1.16

112.08

19.06

21.29

1.84

4.55

7.45

Span in meters 2.75 2.03

3.00 1.71

3.25 1.37

3.50 1.10

3.75 0.89

4.00 0.74

Load Table [ kN/m2 ] Skin Thickness (mm)

Number of Spans 1

Ext. 0.7 2 Int. 0.7 3

1 Ext. 0.7 2 Int. 0.5 3

1 Ext. 0.5 2 Int. 0.5 3

Load Case D+L

1.50 6.27

WP

8.33

6.68

5.12

4.04

3.27

2.71

2.27

1.94

1.65

1.34

1.10

WS D+L

8.81 4.84

7.55 4.15

6.61 3.63

5.87 3.22

4.85 2.90

3.77 2.64

2.90 2.42

2.28 2.16

1.83 1.86

1.49 1.62

1.22 1.42

WP

6.43

5.51

4.83

4.29

3.86

3.51

3.22

2.87

2.47

2.15

1.89

WS D+L

6.67 5.50

5.71 4.71

5.00 4.12

4.04 3.66

3.27 3.08

2.71 2.54

2.27 2.14

1.94 1.82

1.67 1.57

1.46 1.37

1.28 1.20

WP

7.31

6.27

5.48

4.87

4.09

3.38

2.84

2.42

2.09

1.82

1.60

WS D+L

6.94 6.27

5.95 4.73

5.21 3.62

4.63 2.86

4.09 2.32

3.38 1.86

2.84 1.43

2.42 1.13

2.09 0.90

1.82 0.73

1.60 0.60

WP

8.33

6.29

4.82

3.81

3.08

2.55

2.14

1.69

1.35

1.10

0.91

WS D+L

8.81 3.97

7.31 3.41

5.59 2.98

4.42 2.65

3.58 2.38

2.80 2.17

2.16 1.87

1.70 1.59

1.36 1.37

1.11 1.20

0.91 1.05

WP

5.28

4.53

3.96

3.52

3.17

2.88

2.49

2.12

1.83

1.59

1.40

WS D+L

6.67 4.52

5.71 3.87

4.82 3.39

3.81 3.01

3.08 2.71

2.55 2.39

2.14 2.01

1.82 1.71

1.57 1.48

1.37 1.29

1.20 1.13

WP

6.01

5.15

4.50

4.00

3.60

3.18

2.68

2.28

1.97

1.71

1.51

WS D+L

6.94 4.11

5.95 3.02

5.21 2.31

4.63 1.83

3.85 1.48

3.18 1.22

2.68 1.03

2.28 0.82

1.97 0.66

1.71 0.53

1.51 0.44

WP

5.46

4.01

3.07

2.43

1.97

1.63

1.37

1.16

0.98

0.80

0.66

WS D+L

8.56 3.97

6.40 3.41

4.90 2.98

3.87 2.65

3.14 2.36

2.37 1.95

1.83 1.64

1.44 1.40

1.15 1.20

0.94 1.05

0.77 0.92

WP

5.28

4.53

3.96

3.52

3.14

2.59

2.18

1.86

1.60

1.39

1.23

WS D+L

5.46 4.52

4.01 3.77

3.07 2.89

2.43 2.28

1.97 1.85

1.63 1.53

1.37 1.28

1.16 1.09

1.00 0.94

0.87 0.82

0.77 0.72

WP

6.01

5.02

3.84

3.04

2.46

2.03

1.71

1.45

1.25

1.09

0.96

WS

6.72

5.02

3.84

3.04

2.46

2.03

1.71

1.45

1.25

1.09

0.96

1.75 5.02

2.00 3.85

2.25 3.04

2.50 2.46

• D + L = Dead + Live Load (Deflection limit Span/180) • WP = Wind Pressure (Deflection limit Span/120) • WS = Wind Pressure (Deflection limit Span/120) • Material conforming to ALLOY 3003 H26 (Fy = 16.15 kN/cm2) or equivalent

DM 03.10.00

5-16

ZAMIL STEEL BUILDINGS DESIGN MANUAL 5. Secondary members design

PEB DIVISION

Table 5.16 - Tempcon High Rib (TCSP) Insulated Aluminum Panel Total depth 85mm

Section Properties Skin Thickness (mm)

Weight kg/m2

Area cm2

Ix cm4

Top in Compression Zx-Top Zx-Bott. cm3 cm3

Ma kN.m

Ix cm4

Bottom in Compression Zx-Top Zx-Bott. cm3 cm3

Ma kN.m

Web Shear & Cripp. Va Pa kN kN

Exterior

Interior

0.7

0.7

6.47

16.03

105.79

15.16

38.47

1.47

120.20

22.17

31.21

2.14

3.85

9.07

0.7

0.5

5.88

13.89

87.33

14.17

26.05

1.37

90.34

19.02

18.95

1.83

3.85

7.45

0.5

0.5

5.21

11.46

62.46

8.96

24.60

0.87

75.61

14.30

18.37

1.38

3.69

7.45

Span in meters 2.75 1.49

3.00 1.15

3.25 0.90

3.50 0.72

3.75 0.59

4.00 0.49 0.73

Load Table [ kN/m2 ] Skin Thickness (mm)

Number of Spans 1

Ext. 0.7 2 Int. 0.7 3

1 Ext. 0.7 2 Int. 0.5 3

1 Ext. 0.5 2 Int. 0.5 3

Load Case D+L

1.50 5.13

WP

6.82

5.09

3.90

3.08

2.50

2.06

1.73

1.36

1.09

0.88

WS

7.25

6.21

5.44

4.51

3.39

2.55

1.96

1.54

1.23

1.00

0.83

D+L

4.36

3.74

3.27

2.91

2.62

2.27

1.91

1.62

1.40

1.22

1.07

WP

5.80

4.97

4.35

3.87

3.48

3.02

2.53

2.16

1.86

1.62

1.43

WS

5.46

4.68

3.90

3.08

2.50

2.06

1.73

1.48

1.27

1.11

0.97

D+L

4.54

3.89

3.41

2.90

2.35

1.94

1.63

1.39

1.20

1.04

0.92

WP

6.04

5.18

4.53

3.85

3.12

2.58

2.17

1.85

1.59

1.39

1.22

WS

5.69

4.87

4.26

3.79

3.12

2.58

2.17

1.85

1.59

1.39

1.22

D+L

4.87

3.58

2.74

2.17

1.64

1.23

0.95

0.75

0.60

0.49

0.40

WP

6.48

4.76

3.65

2.88

2.33

1.85

1.42

1.12

0.90

0.73

0.60

WS

7.25

6.21

4.87

3.49

2.55

1.91

1.47

1.16

0.93

0.75

0.62

D+L

3.97

3.41

2.98

2.65

2.35

1.94

1.63

1.39

1.20

1.04

0.92

WP

5.28

4.53

3.96

3.52

3.12

2.58

2.17

1.85

1.59

1.39

1.22

WS

5.46

4.68

3.65

2.88

2.33

1.93

1.62

1.38

1.19

1.04

0.91

D+L

4.52

3.87

3.39

2.71

2.19

1.81

1.52

1.30

1.12

0.93

0.77

WP

6.01

5.15

4.50

3.60

2.92

2.41

2.03

1.73

1.49

1.30

1.14

WS

5.69

4.87

4.26

3.60

2.92

2.41

2.03

1.73

1.49

1.30

1.14

D+L

3.08

2.26

1.73

1.37

1.11

0.88

0.68

0.53

0.43

0.35

0.29

WP

4.10

3.01

2.30

1.82

1.47

1.22

1.02

0.80

0.64

0.52

0.43

WS

6.54

4.81

3.68

2.91

2.13

1.60

1.23

0.97

0.78

0.63

0.52

D+L

3.97

3.41

2.77

2.19

1.77

1.46

1.23

1.05

0.90

0.79

0.69

WP

5.28

4.53

3.68

2.91

2.35

1.95

1.64

1.39

1.20

1.05

0.92

WS D+L

4.10 3.85

3.01 2.83

2.30 2.17

1.82 1.71

1.47 1.39

1.22 1.15

1.02 0.96

0.87 0.82

0.75 0.71

0.66 0.62

0.58 0.54

WP

5.12

3.76

2.88

2.28

1.84

1.52

1.28

1.09

0.94

0.82

0.72

WS

5.12

3.76

2.88

2.28

1.84

1.52

1.28

1.09

0.94

0.82

0.72

1.75 3.83

2.00 2.93

2.25 2.32

2.50 1.88

• D + L = Dead + Live Load (Deflection limit Span/180) • WP = Wind Pressure (Deflection limit Span/120) • WS = Wind Pressure (Deflection limit Span/120) • Material conforming to ALLOY 3003 H26 (Fy = 16.15 kN/cm2) or equivalent

DM 03.10.00

5-17

ZAMIL STEEL BUILDINGS DESIGN MANUAL 5. Secondary members design

PEB DIVISION

Table 5.17 - Tempcon High Rib (TCSP) Insulated Aluminum Panel Total depth 75mm

Section Properties Skin Thickness (mm)

Area cm2

Ix cm4

Top in Compression Zx-Top Zx-Bott. cm3 cm3

Ma kN.m

Ix cm4

Bottom in Compression Zx-Top Zx-Bott. cm3 cm3

Ma kN.m

Web Shear & Cripp. Va Pa kN kN

Exterior

Interior

Weight kg/m2

0.7

0.7

6.12

16.03

75.93

12.22

32.89

1.18

88.08

17.65

28.18

1.71

3.29

9.07

0.7

0.5

5.53

13.89

63.02

11.36

22.42

1.10

67.25

15.17

17.30

1.47

3.29

7.45

0.5

0.5

4.86

11.46

44.31

7.04

20.91

0.68

55.61

11.39

16.62

1.10

3.14

7.45

Span in meters 2.75 1.07

3.00 0.83

3.25 0.65

3.50 0.52

3.75 0.42

4.00 0.35 0.52

Load Table [ kN/m2 ] Skin Thickness (mm)

Number of Spans 1

Ext. 0.7 2 Int. 0.7 3

1 Ext. 0.7 2 Int. 0.5 3

1 Ext. 0.5 2 Int. 0.5 3

Load Case D+L

1.50 4.20

WP

5.59

4.11

3.14

2.48

2.01

1.61

1.24

0.97

0.78

0.63

WS

6.23

5.34

4.54

3.41

2.48

1.87

1.44

1.13

0.90

0.74

0.61

D+L

3.75

3.21

2.81

2.50

2.19

1.81

1.52

1.29

1.11

0.97

0.85

WP

4.99

4.27

3.74

3.32

2.91

2.40

2.02

1.72

1.48

1.29

1.14

WS D+L

4.67 3.91

4.00 3.35

3.14 2.93

2.48 2.33

2.01 1.89

1.66 1.56

1.40 1.31

1.19 1.12

1.03 0.96

0.89 0.81

0.79 0.67

WP

5.19

4.45

3.90

3.10

2.51

2.08

1.75

1.49

1.28

1.12

0.98

WS

4.86

4.17

3.64

3.10

2.51

2.08

1.75

1.49

1.28

1.12

0.98

D+L

3.91

2.87

2.20

1.62

1.18

0.89

0.69

0.54

0.43

0.35

0.29

WP

5.20

3.82

2.92

2.31

1.78

1.33

1.03

0.81

0.65

0.53

0.43

WS D+L

6.23 3.75

5.10 3.21

3.70 2.81

2.60 2.32

1.90 1.88

1.42 1.55

1.10 1.30

0.86 1.11

0.69 0.96

0.56 0.83

0.46 0.72

WP

4.99

4.27

3.74

3.08

2.50

2.06

1.73

1.48

1.27

1.11

0.98

WS

4.67

3.82

2.92

2.31

1.87

1.55

1.30

1.11

0.95

0.83

0.73

D+L

3.91

3.35

2.75

2.17

1.76

1.45

1.22

1.04

0.83

0.67

0.56

WP

5.19

4.45

3.65

2.89

2.34

1.93

1.62

1.38

1.19

1.01

0.83

WS D+L

4.86 2.42

4.17 1.78

3.64 1.36

2.89 1.08

2.34 0.83

1.93 0.63

1.62 0.48

1.38 0.38

1.19 0.30

1.04 0.25

0.89 0.20

WP

3.22

2.37

1.81

1.43

1.16

0.94

0.72

0.57

0.46

0.37

0.30

WS

5.21

3.83

2.93

2.15

1.57

1.18

0.91

0.71

0.57

0.46

0.38

D+L

3.70

2.88

2.20

1.74

1.41

1.16

0.98

0.83

0.72

0.62

0.51

WP

4.92

3.83

2.93

2.31

1.87

1.55

1.30

1.11

0.96

0.83

0.73

WS D+L

3.22 3.03

2.37 2.22

1.81 1.70

1.43 1.34

1.16 1.09

0.96 0.90

0.80 0.76

0.69 0.64

0.59 0.56

0.52 0.47

0.45 0.39

WP

4.02

2.96

2.26

1.79

1.45

1.20

1.01

0.86

0.74

0.64

0.57

WS

4.02

2.96

2.26

1.79

1.45

1.20

1.01

0.86

0.74

0.64

0.57

1.75 3.09

2.00 2.36

2.25 1.87

2.50 1.43

• D + L = Dead + Live Load (Deflection limit Span/180) • WP = Wind Pressure (Deflection limit Span/120) • WS = Wind Pressure (Deflection limit Span/120) • Material conforming to ALLOY 3003 H26 (Fy = 16.15 kN/cm2) or equivalent

DM 03.10.00

5-18

ZAMIL STEEL BUILDINGS DESIGN MANUAL 5. Secondary members design

PEB DIVISION

Table 5.18 - Tempcon Low Rib (TCTP) Insulated Aluminum Panel Total depth 60mm

Section Properties Skin Thickness (mm)

Area cm2

Ix cm4

Top in Compression Zx-Top Zx-Bott. cm3 cm3

Ma kN.m

Ix cm4

Bottom in Compression Zx-Top Zx-Bott. cm3 cm3

Ma kN.m

Web Shear & Cripp. Va Pa kN kN

Exterior

Interior

Weight kg/m2

0.7

0.7

6.22

15.01

103.04

27.64

36.00

2.67

103.04

36.00

27.64

2.67

3.60

9.07

0.7

0.5

5.63

12.86

83.19

27.64

24.00

2.32

75.81

36.00

16.11

1.56

3.60

7.45

0.5

0.5

5.04

10.72

64.50

16.11

24.00

1.56

64.50

24.00

16.11

1.56

3.60

7.45

Load Table [ kN/m2 ] Skin Thickness (mm)

Number of Spans 1

Ext. 0.7 2 Int. 0.7 3

1 Ext. 0.7 2 Int. 0.5 3

1 Ext. 0.5 2 Int. 0.5 3

1.75 4.11

2.00 3.60

2.25 2.66

2.50 1.94

Span in meters 2.75 1.46

3.00 1.12

3.25 0.88

3.50 0.71

3.75 0.58

4.00 0.47

6.38

5.47

4.79

3.99

2.91

2.19

1.69

1.33

1.06

0.86

0.71

6.38

5.47

4.79

3.99

2.91

2.19

1.69

1.33

1.06

0.86

0.71

D+L

3.84

3.29

2.88

2.56

2.30

2.09

1.92

1.77

1.65

1.44

1.18

WP

5.11

4.38

3.83

3.40

3.06

2.79

2.55

2.36

2.19

2.02

1.78

WS

5.11

4.38

3.83

3.40

3.06

2.79

2.55

2.36

2.19

2.02

1.78

D+L

4.00

3.43

3.00

2.67

2.40

2.18

2.00

1.70

1.36

1.11

0.91

WP

5.32

4.56

3.99

3.55

3.19

2.90

2.66

2.46

2.04

1.66

1.37

WS

5.32

4.56

3.99

3.55

3.19

2.90

2.66

2.46

2.04

1.66

1.37

D+L

4.80

4.11

3.06

2.15

1.57

1.18

0.91

0.71

0.57

0.46

0.38

WP

6.38

5.47

4.59

3.23

2.35

1.77

1.36

1.07

0.86

0.70

0.57

WS

6.38

5.41

4.14

2.94

2.14

1.61

1.24

0.98

0.78

0.63

0.52

D+L

3.84

3.29

2.88

2.46

1.99

1.65

1.38

1.18

1.02

0.89

0.78

WP

5.11

4.38

3.83

3.27

2.65

2.19

1.84

1.57

1.35

1.18

1.04

WS

5.11

4.38

3.83

3.40

3.06

2.79

2.55

2.34

1.95

1.59

1.31

D+L

4.00

3.43

3.00

2.67

2.40

2.06

1.73

1.37

1.10

0.89

0.74

WP

5.32

4.56

3.99

3.55

3.19

2.74

2.30

1.96

1.65

1.34

1.10

WS

5.32

4.56

3.99

3.55

3.19

2.74

2.30

1.87

1.50

1.22

1.01

D+L

4.80

3.54

2.37

1.67

1.22

0.91

0.70

0.55

0.44

0.36

0.30

WP

6.38

5.31

3.56

2.50

1.82

1.37

1.05

0.83

0.66

0.54

0.45

WS

6.38

5.31

3.56

2.50

1.82

1.37

1.05

0.83

0.66

0.54

0.45

D+L

3.84

3.29

2.88

2.46

1.99

1.65

1.38

1.18

1.02

0.89

0.74

WP

5.11

4.38

3.83

3.27

2.65

2.19

1.84

1.57

1.35

1.18

1.04

WS

5.11

4.38

3.83

3.27

2.65

2.19

1.84

1.57

1.35

1.18

1.04

D+L

4.00

3.43

3.00

2.67

2.34

1.75

1.35

1.06

0.85

0.69

0.57

WP

5.32

4.56

3.99

3.55

3.19

2.63

2.03

1.59

1.28

1.04

0.86

WS

5.32

4.56

3.99

3.55

3.19

2.63

2.03

1.59

1.28

1.04

0.86

Load Case D+L

1.50 4.80

WP WS

• D + L = Dead + Live Load (Deflection limit Span/180) • WP = Wind Pressure (Deflection limit Span/120) • WS = Wind Pressure (Deflection limit Span/120) • Material conforming to ALLOY 3003 H26 (Fy = 16.15 kN/cm2) or equivalent

DM 03.10.00

5-19

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

5. Secondary members design

5.2. Secondary Structural Framing The secondary structural framing includes roof Purlins, Side & end wall girts and eave struts. The cross sections used for those members are cold formed sections, types of cold formed sections used and their properties & design tables are as follows:-

DM 03.10.00

5-20

ZAMIL STEEL BUILDINGS DESIGN MANUAL 5. Secondary members design

PEB DIVISION

5.2.1. Cold Formed Cross Sections Properties and Capacities 5.2.1.1. 200mm depth Z-sections Notes :-

20

Y 6M R=

Dimensions are out to out of section thickness ‘t’.

2.

All sections are designed in accordance with the Cold-Formed Steel Design Manual, AISI 1986 Edition.

3.

Specific yield strength Fy of light gauge cold-formed steel = 2 34.50 kN/cm

4. 5.

Coil width = 345mm For the properties of Nested Purlins add the appropriate individual section properties except Rx, Ry and H/t.

6.

Section are used for roof purlins & wall girts

M

1.

d

X

X

200 Z 20 t = THICKNESS SHAPE d=Depth Y 60MM

Table 5.19 Section Properties Ix

Section

4

(cm )

About X-X Axis Gross Effect. Sxc Sxc = Sx 3 (cm ) 3 (cm )

About Y-Y Axis Iyc Sy

Rx

Iy

(cm)

(cm )

(cm )

4

4

Others Rmin

Ry

Ixy

(cm )

3

(cm)

(cm )

(cm)

4

200Z15

308.3

30.83

26.28

7.72

42.49

21.25

5.98

2.87

83.08

1.91

200Z17

358.8

35.88

31.50

7.71

49.86

24.93

7.01

2.87

97.11

1.92

200Z20

409.1

40.91

38.49

7.70

57.30

28.65

8.05

2.88

111.20

1.92

200Z22

459.1

45.91

44.41

7.69

64.83

32.41

9.10

2.89

125.34

1.93

200Z25

509.0

50.90

50.90

7.68

72.43

36.22

10.16

2.90

139.52

1.93

200Z30

607.9

60.79

60.79

7.66

87.88

43.94

12.32

2.91

168.03

1.94

Section Capacities Allowable Shear Force

General Data Section Weight (kg/m)

Thick (mm)

Area 2 (cm )

200Z15

4.06

1.50

5.18

200Z17

4.74

1.75

200Z20

5.42

200Z22

Effect. Area 2 (cm )

Allowable Bending Moment (kN.m)

H/t

(kN)

Ma*

Ma2**

4.90

123.33

10.33

5.43

5.07

6.04

5.77

105.43

16.44

6.51

6.07

2.00

6.90

6.74

92.00

24.61

7.95

7.42

6.09

2.25

7.76

7.66

81.56

35.14

9.17

8.56

200Z25

6.77

2.50

8.62

8.62

73.20

45.59

10.51

9.81

200Z30

8.12

3.00

10.35

10.35

60.67

65.65

12.56

11.72

(*) (Sxc)Effective x 0.6fy (**) Based on a reduction factor of 0.70 for continuous spans and an increase of 33% on allowable stress for wind load applications resulting in compression in the unrestraint flange while the other tension flange are fastened to sheeting. (Applicable only if the span of the longest member is not more than 20% longer than the shortest span). For simple spans multiply Ma2 values by 0.5/0.7.

DM 03.10.00

5-21

ZAMIL STEEL BUILDINGS DESIGN MANUAL 5. Secondary members design

PEB DIVISION

5.2.1.2. 250mm depth Z-sections Notes :21

Y

1. Dimensions are out to out of section thickness ‘t’. M 6M R=

d

X

2. All sections are designed in accordance with the Cold-Formed Steel Design Manual, AISI 1986 Edition.

X

3. Specific yield strength Fy of light gauge cold-formed steel = 2 34.50 kN/cm

250 Z 20 t = THICKNESS SHAPE d=Depth

4. Coil width = 390mm 5. For the properties of Nested Purlins add the appropriate individual section properties except Rx, Ry and H/t. 6. Section is used for roof purlins & wall girts (Special loads or bay spacings.

Y 60MM

Table 5.20 Section Properties About X-X Axis Ix

Section

4

(cm )

Gross Effect. Sxc Sxc = Sx 3 (cm ) 3 (cm )

About Y-Y Axis Rx

Iy

Iyc

(cm)

(cm )

(cm )

4

Sy

4

Others Ry

Ixy

(cm )

(cm)

(cm )

(cm)

3

Rmin

4

250Z20

661.5

54.0

51.64

9.21

56.78

28.39

8.1

2.7

136.4

1.88

250Z25

823.7

67.24

67.24

9.19

71.72

35.86

10.22

2.71

171.21

1.89

Section Capacities Allowable Shear Force

General Data Section Weight (kg/m)

Thick (mm)

Area 2 (cm )

250Z20

6.12

2.0

7.80

250Z25

7.65

2.5

9.75

Effect. Area 2 (cm )

Allowable Bending Moment (kN.m)

H/t

(kN)

Ma*

Ma2**

7.67

114.5

19.77

10.67

9.96

9.75

91.2

38.79

13.89

12.97

(*) (Sxc)Effective x 0.6fy (**) Based on a reduction factor of 0.70 for continuous spans and an increase of 33% on allowable stress for wind load applications resulting in compression in the unrestraint flange while the other tension flange are fastened to sheeting. (Applicable only if the span of the longest member is not more than 20% longer than the shortest span). For simple spans multiply Ma2 values by 0.5/0.7.

DM 03.10.00

5-22

ZAMIL STEEL BUILDINGS DESIGN MANUAL 5. Secondary members design

PEB DIVISION

5.2.1.3. Z-sections overlaps Z-shaped purlins are adopted for pre-engineered buildings that can provide a great advantage of being lapped at support points and nested together in order to increase the stiffness. This capability provides additional strength and reduces deflections. Type of Laps: There are three types of Purlin laps used according to lap length: 1. Short Lap: These purlins are with a 130-mm total lap over supports (65 mm from either side), and distance between bolts being 80 mm. This lap is constant whether it occurs in end bays or in interior bays. This type of lap is normally used for short bays (< 6m) and light loads. The capacity of this lap connection is determined as follows: Allowable shear per 12 mm A307 bolt = 7.8 kN. Therefore allowable couple = 0.08 x 7.8 x 2 = 1.25 kN-m 2. Continuous Lap: For moderate bays (6m-9m) the lap is 385mm on either side of support making the total lap length of 770mm. It is termed ‘Continuous Lap’ since it provides a reasonable continuity of purlins over the supports. 3. Long Lap: For long bays (> 9m) the lap length is of 705 mm on either side of support. It is referred as `Long Lap'. This type of lap provides almost full continuity used for long bays and heavier loads. Purlin Lap Details Note: All Bolts M12 - MB A307



NOTE: For nested Z-purlins (full laterally restraint) bending moment and shear force capacities are the summations of capacities of the individual sections.

DM 03.10.00

5-23

ZAMIL STEEL BUILDINGS DESIGN MANUAL 5. Secondary members design

PEB DIVISION

5.2.1.4. 120mm depth C-sections Notes :60mm

1.

Dimensions are out to out of section thickness, t.

2.

All sections are designed in accordance with the Cold-Formed Steel Design Manual, AISI 1986 Edition

3.

Specific yield strength “Fy” of light gauge cold2 formed steel = 34.50 kN/cm

4.

C.G. = Center of Gravity

5.

S.C. = Shear Center

6.

Coil width = 260 mm

L

Y

d

S.C. X

C.G. X

120 C 20 t = THICKNESS SHAPE d=Depth

Xcg

Xcm

Y

7. Section are used for framed openings, Doors Table 5.21 Section Properties Gross Ix 4 (cm )

About X-X Axis Defl. Gross Eff. Ix Sx Sx 4 3 4 (cm ) (cm ) (cm )

Rx

Iy

(cm)

120C20

120.2

120.2

20.04

20.04

120C25

148.5

148.5

24.76

120C30

175.9

175.9

29.33

Section

(cm )

About Y-Y Axis Min. Max. Sy Sy 4 3 3 (cm ) (cm ) (cm )

(cm )

(cm )

(cm )

4.81

25.97

12.99

6.58

12.67

2.24

2.05

2.921

24.76

4.78

32.34

16.71

8.26

15.51

2.23

2.085

2.924

29.33

4.75

38.67

19.33

9.97

18.23

2.23

2.121

2.294

Iyc

4

Others Xcm Xcg

Ry

Section Capacities Allowable Shear Force

General Data Section

Allowable Bending Moment (kN-m)

Effect Area 2 (cm )

H/t

(kN)

(mm)

Gross Area 2 (cm )

Mag

Maws *

2.0

17.43

5.20

5.20

55.00

29.38

3.21

1.71

5.10

2.5

18.65

6.50

6.50

43.60

37.57

4.04

2.15

6.12

3.0

19.86

7.80

7.80

36.00

44.67

4.85

2.58

Weight

Thick

L

(kg/m)

(mm)

120C20

4.08

120C25 120C30

(*) Based on a reduction factor of 0.40 for simple spans with one unbraced compression side and an increase of 33% on allowable stress for wind load application.

DM 03.10.00

5-24

ZAMIL STEEL BUILDINGS DESIGN MANUAL 5. Secondary members design

PEB DIVISION

5.2.1.5. 200mm depth C-sections Notes :85mm

1.

Dimensions are out to out of section thickness, t.

2.

All sections are designed in accordance with the ColdFormed Steel Design Manual, AISI 1986 Edition

3.

Specific yield strength “Fy” of light gauge cold-formed 2 steel = 34.50 kN/cm

4.

C.G. = Center of Gravity

5.

S.C. = Shear Center

6.

Coil width = 390 mm

7.

Section are used for framed openings, wall girts & end wall posts and beams, mezzanine Joist.

d

L

Y

S.C. X

C.G. X

200 C 20 t = THICKNESS SHAPE d=Depth

Xcg

Xcm

Y

Table 5.22 Section Properties Gross Ix 4 (cm )

About X-X Axis Defl. Gross Eff. Ix Sx Sx 4 3 4 (cm ) (cm ) (cm )

Rx

Iy

(cm)

200C20

491.7

481.8

49.17

41.45

200C25

610.6

609.9

61.06

53.71

Section

(cm )

About Y-Y Axis Min. Max. Sy Sy 4 3 3 (cm ) (cm ) (cm )

(cm )

(cm )

(cm )

7.86

73.37

36.69

12.12

29.98

3.07

2.447

3.989

7.91

91.76

45.88

15.19

37.32

3.07

2.459

4.016

Iyc

4

Others Xcm Xcg

Ry

Section Capacities Allowable Shear Force

General Data Section

Allowable Bending Moment (kN-m)

Effect Area 2 (cm )

H/t

(kN)

Mag

Maws *

(mm)

Gross Area 2 (cm )

2.0

20.0

7.80

7.28

92.0

25.03

8.56

4.55

2.5

21.2

9.75

9.23

73.2

45.98

11.10

5.91

Weight

Thick

L

(kg/m)

(mm)

200C20

6.11

200C25

7.64

(*) Based on a reduction factor of 0.40 for simple spans with one unbraced compression side and an increase of 33% on allowable stress for wind load application.

DM 03.10.00

5-25

ZAMIL STEEL BUILDINGS DESIGN MANUAL 5. Secondary members design

PEB DIVISION

5.2.1.6. 300mm depth C-sections

Notes:

85mm

L

Y

S.C. X

C.G. X

2.

Dimensions are out to out of section thickness, t.

3.

All sections are designed in accordance with the Cold-Formed Steel Design Manual, AISI 1986 Edition.

4.

Specific yield strength “Fy” of light gauge cold-formed 2 steel = 34.50 kN/cm

5.

C.G. = Center of Gravity

6.

S.C. = Shear Center

7.

Coil width = 495 mm

8.

Section is used as end wall rafter and posts mezzanine Joist.

d

300 C 20 t = THICKNESS SHAPE d=Depth

Xcg

Xcm

Y

Table 5.23 Section Properties Section

300C20

Gross Ix 4 (cm )

About X-X Axis Defl. Gross Sx Eff. 3 Ix (cm ) Sx 3 4 (cm ) (cm )

1308.5 1308.5

87.23

74.29

(cm )

About Y-Y Axis Min. Max. Sy Sy 4 3 3 (cm ) (cm ) (cm )

(cm )

(cm )

(cm )

91.81

45.91

3.04

2.19

3.61

Rx

Iy

(cm) 11.50

Iyc

4

14.55

41.90

Ry

Others Xcg Xcm

Section Capacities Allowable Shear Force

General Data

Allowable Bending Moment (kN.m)

Section

300C20

Weight

Thick

L

Effect Area 2 (cm )

H/t

(kN)

Ma

Ma2*

(mm)

Gross Area 2 (cm )

(kg/m)

(mm)

7.78

2.0

25.65

9.90

9.14

142.0

15.94

15.34

8.18

(*) Based on a reduction factor of 0.40 for simple spans with one unbraced compression side and an increase of 33% on allowable stress for wind load application.

DM 03.10.00

5-26

ZAMIL STEEL BUILDINGS DESIGN MANUAL 5. Secondary members design

PEB DIVISION

5.2.1.7. Double ‘C’ -sections - Double ‘C’ section are C-sections connected back to back using stitch bolts forming assembled I-section used as end wall posts & rafters or as mezzanine joists. - C-section of depths 200mm and 300mm are used for assembled I–sections. - For Fully Lateral Braced sections the capacity of the double sections capacities are twice the single sections capacities (tables 5.22&5.23). - For cases of sections laterally braced at intervals (gable posts & rafters) the section properties about axis YY are calculated as I –section for the cases when the stitch bolts spacing satisfying the requirements of AISI 1986,1989 addendum clause (D1.1.) otherwise two ‘C’ section are considered acting independently. - The section properties of the double ‘C’ satisfying the AISI requirements above are as follows

Y 85mm

L

85mm

200 ][ 20 d

C.G. X

X

t = THICKNESS SHAPE d=Depth

S.C.

Y

Table 5.24 – 200 Double ‘C’ -Section Properties SECTION PROPERTIES ABOUT X-X AXIS Defl. Gross Ix. Sx. 4 3 cm cm

SECTION

Gross Ix 4 cm

200][20

982.0

963.66

200][25

1221.2

300][20

2617

DM 03.10.00

ABOUT Y-Y AXIS Eff. Sx. 3 cm

Rx. cm

Iy 4 cm

Iyc 4 Cm

Sy 3 cm

Ry cm

98.34

82.90

7.86

240.8

120.4

28.33

3.90

1219.8

132.12

107.42

7.91

302

151

35.53

3.94

2617

174.46

148.58

11.50

278.6

139.4

32.77

3.75

5-27

ZAMIL STEEL BUILDINGS DESIGN MANUAL 5. Secondary members design

PEB DIVISION

5.2.1.8. Eave Strut-section Notes: 1. Calculation dimensions are out to out of Section thickness, t. 2. All Sections are designed with reference to the Specifications of "Cold-Formed Steel Design Manual" AISI 1986 Edition. 3. Specific yield strength of light gage Cold-Formed steel Fy = 34.50 KN/cm2 4. (+) Based on reduction factor of 0.40 for simple span due to wind load uplift or suction - with 33% increase (with fully unbraced compression flange). 5. (*) Based on reduction factor of 0.60 for continuous span due to wind load uplift or suction - with 33% increase (Applicable if the longest member span is not more than 20% of the shortest span). 6. CG = Center of Gravity. 7. SC = Shear Center 8. Used as eave strut

Table 5.25 Section Properties GENERAL DATA SECTION

WEIGHT KG/M

THICK mm

L mm

180ES20 180ES25

5.88 7.35

2.0 2.5

22.50 26.70

Legend: G = gravity

W = wind

GROSS AREA cm2 7.50 9.38

C = continuous

EFF. AREA cm2 7.00 8.93

H/t

82.00 65.20

ALLOW. SHEAR FORCE KN

28.09 45.98

NOMINAL MOMENT STRENGT H KN-M 12.78 16.72

ALLOWABLE BENDING MOMENT (KN-M) (Ma)g

(Ma)wc*

(Ma)ws+

7.65 10.01

6.11 8.00

4.07 5.33

S = simple span

Section Capacities SECTION PROPERTIES SECTION

180ES20 180ES25

DM 03.10.00

Gross Ix cm4 390.5 484.1

ABOUT X-X AXIS Defl. Gross Eff. Ix Sx Sx 4 3 cm cm cm3 387.20 43.40 37.00 484.30 53.80 48.45

Rx cm

Iy cm4

7.21 7.19

74.10 92.50

ABOUT Y-Y AXIS Min. Max. Sy Sy 3 cm cm3 37.10 12.70 27.90 46.30 15.90 34.70 Iyc cm3

Ry cm

OTHERS Xcg cm

3.14 3.14

2.66 2.67

5-28

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

5. Secondary members design

5.2.2. Design Of Roof Purlins Purlins are secondary members supporting the roof panels, sections used for roof purlins are Z-sections. 5.2.2.1 Roof Purlins design loads • • •

Gravity loads [Dead , Live , Collateral (if any) , Snow (if any)] Wind loads [uplift (suction) , pressure] Axial force due to the longitudinal wind loads especially the strut purlins (refer to chapter 7).

5.2.2.2. Roof Purlins design concept Purlin top flanges are assumed to be restrained against lateral buckling by the roof panels. The coldformed purlins are designed as per AISI (Cold-Formed Steel Design Manual 1986) Sections B and C. The performance and allowable stresses depends on the loading conditions 1. Under gravity loads Gravity loads have two components perpendicular to the sheeting and laterally in the direction of sheeting, The perpendicular component is carried by roof purlins only producing Mx (major axis bending) and the lateral component is carried by shear diaphragm consisting of sheeting and purlins. For cases of non symmetrical pitched roof about ridge (geometry & loading), loads are transferred from the plane of sheeting to the plane of rafter’s top flange, producing relative displacement between purlin top flange and purlin reaction point. AISI (Cold-Formed Steel Design Manual 1986) limits this relative displacement to (purlin span/360) (1) The specification requires anchored braces to be connected to only one line of purlins in each purlin bay of each roof slope if provision is made to transmit forces from other purlin lines through the roof sheeting and its fastening system. This bracing system reduces the lateral displacement thus ensures purlin top flange fully restraint and transmit the lateral forces to the rafter’s top flange plane. Braces at supports, mid span or one third points are suggested by specifications. Finite element study for different slopes under gravity loads was carried out, the results of this study lead to the following conclusions:1) Although Z-sections are point symmetrical thus the stresses should be calculated about the principle axes but due to top flange restraint by sheeting the actual stresses doesn’t exceed the value (Mx / Zx) at any point regardless of roof slope or restraint condition. 2) Anchored Braces (AB) at supports are needed starting from roof slope 2:10 to reduce the lateral displacement and ensure that purlins top flanges adequately restraint. 3) Sag rods/angles are also needed starting from the same roof slope 2:10 for erection purposes and also to reduce the lateral displacement of the bottom flange at purlins mid span. 4) Only One line of purlins of each roof slope to be braced and the forces from other purlins to be transmitted through sheeting. 5) The line of purlins to be braced is the nearest to the peak point of the slope or at the lines were sheeting interrupts (Example: Roof monitor). 6) Anchored Braces can be moved to the next purlin line In case of any obstruction.

(1)

Clause (D3.2.1.) Page (I-58) AISI Cold-Formed Steel Design Manual 1986 Edition ,1989 Addendum

DM 03.10.00

5-29

ZAMIL STEEL BUILDINGS DESIGN MANUAL 5. Secondary members design

PEB DIVISION

7) The purlin Anchored Braces (min L50x50x3) connecting purlins with rafter’s top flange as shown in the following sketch.

Purlin anchor brace (AB) For continuous lap 8) The force in anchor braces in continuous multiple span Z-purlin restraint at supports can be calculated as follows∗:-

Where:-

 0.053b1.88 L0.13  p L = C tr  Sinθ − 0.95 1.07 0.94  *W nP d t  

PL

= The force in anchor brace angle when PL are positive the brace angle is under tension otherwise under compression.

Ctr

= 0.63 = 0.87 = 0.81

b d t L θ nP W

= Flange width = Depth of the section = thickness = span length = angle between the vertical and the plane of the web of Z-section, degree = No. of parallel purlin lines. (between 4-20) = Total gravity load supported by the purlin lines between adjacent supports.



for braces at end supports of multiple span systems for braces at the first interior supports for all other braces

Eq. (D3.2.1-4) Page (I-59) AISI Cold-Formed Steel Design Manual 1986 Edition ,1989 Addendum

DM 03.10.00

5-30

ZAMIL STEEL BUILDINGS DESIGN MANUAL 5. Secondary members design

PEB DIVISION

2. Under wind load (suction) Under suction the compression flange is the bottom unrestraint flange. The moment capacities of the sections are reduced by factor depending on the section shape and span type. Referring to tables from (5.19 – 5.20) the moment capacities of different sections for different cases are calculated. 3. Axial loads When purlins act as roof bracing truss member (refer to chapter 7), the allowable axial stress is then calculated as per Section C 4 of AISI 1986 Manual and combined stresses to be checked as per C 5 of AISI 1986 Manual. Purlins when designed for load combinations with wind loads; allowable stresses are increased by 33%. Checking the purlins under different loading is carried out using ASFAD (Purlin input), AISI 1980 and AISI 1986 codes are available. For the cases when purlins at braced bays fails under axial and bending try consequently one of the following :• Reinforce the existing purlin section with anther nested purlin at the braced bay •

Add strut purlin (Det.#3) at distance 200mm from original purlin, the axial force now is divided between the original purlin and the strut purlin, the original purlin is checked under combined bending moment and half axial loads, The strut purlin is to be connected to original purlins using 200Z15 pieces each (2000mm) to ensure that strut purlin is laterally restraint.



Add strut tube (refer to table 9.10 for sections properties & allowable loads) axial loads are carried by the strut tube and purlins are designed only for bending moment. Below is guide table for choosing sections to be checked using ASFAD Table 5.26 – Roof purlin design BAY SPACING (M)

6.0

6.5

7.0

7.5

8.0

8.5

9.0

WIND SPEED (KMPH) LIVE LOAD (KN/M2) END BAY SECOND BAY INTERIOR BAY END BAY SECOND BAY INTERIOR BAY END BAY SECOND BAY INTERIOR BAY END BAY SECOND BAY INTERIOR BAY END BAY SECOND BAY INTERIOR BAY END BAY SECOND BAY INTERIOR BAY END BAY SECOND BAY INTERIOR BAY

110

130

150

0.57

1.0

0.57

1.0

0.57

1.0

Z15 SHORT Z15 SHORT Z15 SHORT Z15 SHORT Z15 SHORT Z15 SHORT Z15 CONT Z15 CONT Z15 CONT Z15 CONT Z15 CONT Z15 CONT Z17 CONT Z17 CONT Z15 CONT Z17 CONT Z17 CONT Z15 CONT Z20 CONT Z20 CONT Z17 CONT

Z15 CONT Z15 CONT Z15 CONT Z17 CONT Z17 CONT Z15 CONT Z20 CONT Z20 CONT Z17 CONT Z20 CONT Z20 CONT Z17 CONT Z22 CONT Z22 CONT Z20 CONT Z25 CONT Z25 CONT Z20 CONT Z30 LONG Z22 LONG Z20 LONG

Z15 CONT Z15 CONT Z15 CONT Z17 CONT Z15 CONT Z15 CONT Z17 CONT Z15 CONT Z15 CONT Z20 CONT Z15 CONT Z15 CONT Z22 CONT Z17 CONT Z15 CONT Z25 CONT Z17 CONT Z15 CONT Z30 CONT Z20 CONT Z17 CONT

Z15 CONT Z15 CONT Z15 CONT Z17 CONT Z17 CONT Z15 CONT Z20 CONT Z20 CONT Z17 CONT Z20 CONT Z20 CONT Z17 CONT Z22 CONT Z22 CONT Z20 CONT Z25 CONT Z25 CONT Z20CONT Z30 LONG Z22 LONG Z20 LONG

Z17 CONT Z15 CONT Z15 CONT Z20 CONT Z15 CONT Z15 CONT Z22 CONT Z17 CONT Z15 CONT Z25 CONT Z20 CONT Z15 CONT Z30 CONT Z20 CONT Z17 CONT Z40 CONT Z22 CONT Z17CONT Z40 CONT Z25 CONT Z20 CONT

Z17 CONT Z15 CONT Z15 CONT Z20 CONT Z17 CONT Z15 CONT Z22 CONT Z20 CONT Z17 CONT Z25 CONT Z20 CONT Z17 CONT Z30 CONT Z22 CONT Z20 CONT Z40 CONT Z25 CONT Z20 CONT Z40 LONG Z22 LONG Z20 LONG

NOTES: The following are the points that have been considered for the above table. 1) 8 continuous bays 4) Refer standard lap lengths for short, continuous and long laps. 2) Dead load, DL = 0.10KN/M2 (inc. Self Weight) 5) Eave Height = 9m 3) Purlin Spacing = 1.5 M. 6) The maximum possible load combinations considered are: DL+LL; DL+WL 7) Design according to AISI 1986 Manual for the Design of cold-formed steel members.

DM 03.10.00

5-31

ZAMIL STEEL BUILDINGS DESIGN MANUAL 5. Secondary members design

PEB DIVISION

5.2.2.3. Roof Purlins connections Different types of roof purlins standard connections are shown below:-

200Z15 L=250mm @2000mm

PURLIN STRUT

NORMAL PURLIN

SDS 5.5X25mm STRUT CLIP (05-0139)

SDS 5.5X25mm

60

60

STRUT CLIP

25

(2) - M12 x 35mm MSB

25

200

STANDARD PURLIN

(6) - M12 x 35mm MSB WITH STRUT CLIP SHEAR CAPACITY: 41.5kN

(8) - M12 x 35mm MSB

SHEAR CAPACITY: 20.7kN DETAIL #1

STRUT PURLIN W/STRIT CLIP SHEAR CAPACITY: 62.2kN

DETAIL #4

DETAIL #3

200Z15 L=250mm @2000mm PURLIN STRUT

Using SDS 5.5x25mm

STRUT CLIP

60

60

80

80

NORMAL PURLIN

200

(4) - M12 x 35mm MSB CLIP CONNECTED PURLIN

(8) - M12 x 35mm MSB

SHEAR CAPACITY : 41.5KN

CLIP CONNECTED STRUT PURLIN

DETAIL #5

SHEAR CAPACITY : 83.0KN DETAIL #6

Shear Capacity of Purlin Connections

(M12 A307 Bolt shear: 1.13 x 6.8948 x 1.33 = 10.37kN)

Detail #1: 2 bolts in single shear ⇒ Shear Capacity: 2 x 10.37 = 20.74kN Detail #3: 6 bolts in single shear ⇒ Shear Capacity: 6 x 10.37 = 62.23kN Detail #4 & #5: 4 bolts in single shear ⇒ Shear Capacity: 4 x 10.37 = 41.48kN Detail #6: 8 bolts in single shear ⇒ Shear Capacity: 8 x 10.37 = 82.97kN * Both purlin’s combined stresses and purlin’s connections should be checked to support the axial loads acting on purlins due to wind.

DM 03.10.00

5-32

ZAMIL STEEL BUILDINGS DESIGN MANUAL 5. Secondary members design

PEB DIVISION

5.2.3. Design Of Wall Girts Girts are used to provide framework for wall cladding for sidewalls and endwalls. Our standard practice is to employ Z-sections by-framed (by-pass) construction for sidewall girts using the advantage of lapped girts, and Z-sections or C-sections flush construction for endwall girts in order to use diaphragm action effectively (refer to clause 6.4). 5.2.3.1. Wall Girts Design Loads Wind Load (Suction & Pressure) is producing bending about major axis. 5.2.3.2. Wall Girt Design Concept: Girts outside flanges are assumed to be restrained against lateral buckling by the wall panels. For the case of wind pressure the outside restraint flange is in compression. For the case of wind suction inside unrestraint flange is in compression, The moment capacities of the sections are reduced by factor (as per AISI 1986 clause C3.1.3) depending on the section shape and span type. Referring to tables from (5.19-5.23) the moment capacities of different sections for different cases are calculated. Sag Rods: If bay spacing exceeds 8.5m, sag rods are employed to reinforce the girt in the minor axis against dead load (due to self-weight). For bay spacing exceeding 9.5m, two rows of sag rods are used at one third locations of that bay. Checking the girts under different loading are carried using ASFAD (Purlin input), AISI 1980 and AISI 1986 codes are available. Below is guide tables for choosing sections to be checked using ASFAD (Purlin input). Table 5.27 – End Wall Girts Design GIRT SPAN (M)

3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0

110 (0.56)

120 (0.66)

Z15 Z15 Z15 Z15 Z17 Z20 Z22 Z25 Z30 Z30 Z40 Z45 Z45

Z15 Z15 Z15 Z15 Z20 Z20 Z25 Z30 Z35 Z40 Z45 Z50

WIND SPEED in KPH (q in kN/m2) 130 140 (0.78) (0.90)

Z15 Z15 Z15 Z17 Z20 Z25 Z30 Z40 Z40 Z45 Z50

Z15 Z15 Z17 Z20 Z22 Z30 Z35 Z40 Z45 Z50

150 (1.04)

160 (1.18)

Z15 Z15 Z20 Z22 Z25 Z30 Z40 Z45 Z50

Z15 Z17 Z20 Z25 Z30 Z40 Z45 Z50

NOTES: The following points have been considered for the above table. 1) Designed for Simple Span 5) Eave Height = 9m 2) Tributary Width = 1.9m 6) Wind Pressure and Suction both have been considered 3) Deflection Limit = Span /120 4) MBMA GCp Coefficients used for fully enclosed building condition.

DM 03.10.00

5-33

ZAMIL STEEL BUILDINGS DESIGN MANUAL 5. Secondary members design

PEB DIVISION

Table 5.28 – Side Wall Girts Design BAY SPACING (M) 6.0

6.5

7.0

7.5

8.0 8.5

9.0

WIND SPEED in KPH (q in kN/m2) END BAY SECOND BAY INTERIOR BAY END BAY SECOND BAY INTERIOR BAY END BAY SECOND BAY INTERIOR BAY END BAY SECOND BAY INTERIOR BAY END BAY SECOND BAY INTERIOR BAY END BAY SECOND BAY INTERIOR END BAY SECOND BAY INTERIOR BAY

110 (0.56)

120 (0.66)

130 (0.78)

140 (0.90)

150 (1.04)

160 (1.18)

Z15 SHORT Z15 SHORT Z15 SHORT Z15 SHORT Z15 SHORT Z15 SHORT Z15 SHORT Z15 SHORT Z15 SHORT Z15 CONT Z15 CONT Z15 CONT Z15 CONT Z15 CONT Z15 CONT Z17 CONT Z17 CONT Z15 CONT Z17 CONT Z17 CONT Z15 CONT

Z15 SHORT Z15 SHORT Z15 SHORT Z15 SHORT Z15 SHORT Z15 SHORT Z15 CONT Z15 CONT Z15 CONT Z15CONT Z15 CONT Z15 CONT Z17 CONT Z17 CONT Z15 CONT Z17 CONT Z17 CONT Z15 CONT Z20 CONT Z20 CONT Z17 CONT

Z15 CONT Z15 CONT Z15 CONT Z15 CONT Z15 CONT Z15 CONT Z15CONT Z15 CONT Z15 CONT Z17 CONT Z17 CONT Z15 CONT Z20 CONT Z20 CONT Z15 CONT Z20 CONT Z20 CONT Z17 CONT Z22 CONT Z22 CONT Z20 CONT

Z15 CONT Z15 CONT Z15 CONT Z15 CONT Z15 CONT Z15 CONT Z17 CONT Z17 CONT Z15 CONT Z20 CONT Z20 CONT Z15 CONT Z20 CONT Z20 CONT Z17 CONT Z22 CONT Z22 CONT Z20 CONT Z25 CONT Z25 CONT Z20 CONT

Z15 CONT Z15 CONT Z15 CONT Z17 CONT Z17 CONT Z15 CONT Z20 CONT Z20 CONT Z17 CONT Z20 CONT Z20 CONT Z17 CONT Z22 CONT Z22 CONT Z20 CONT Z25 CONT Z25 CONT Z20 CONT Z30 LONG Z22 LONG Z20 LONG

Z17 CONT Z17 CONT Z15 CONT Z17 CONT Z17 CONT Z17 CONT Z20 CONT Z20 CONT Z17 CONT Z22 CONT Z22 CONT Z20 CONT Z25 CONT Z25 CONT Z20 CONT Z30 LONG Z22 LONG Z20 LONG Z35 LONG Z25 LONG Z22 LONG

NOTES: The following points have been considered for the above table. 1) 2) 3) 4)

8 continuous bays. Tributary Width = 1.9m Refer standard lap lengths for short, continuous and long laps. Wind Pressure and Suction both have been considered.

5) MBMA GCp Coefficients used. 6) Eave Height = 9m 7) Fully Enclosed Building Condition 8) Deflection Limitation = Span/120

5.2.3.3. Wall Girt Connections

MAIN FRAME COLUMN FLANGE

END WALL COLUMN

05-0137

(2) - M12 x 35mm MSB

BY-PASS SIDE WALL GIRT

DM 03.10.00

(2) - M12 x 35mm MSB

FLUSH END WALL GIRT

5-34

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

5. Secondary members design

5.2.4. Design Of Eave Struts Eave struts simply supported members 180 mm in depth and 2.0 mm or 2.5 mm in thickness. The section properties are shown in table (5.25). Eave struts are well suited at the corners to support sheeting. 5.2.4.1. Eave strut Design Loads In addition axial loads accumulated through bracings (refer to chapter 7) eave struts may also be subjected to the gravity (DL+LL) and the wind uplift (suction). 5.2.4.2. Eave strut Design Concept: 1. Eave strut is laterally restraint and fully supported by roof sheeting. 2. The wall sheeting is considered to provide full support for eave strut against vertical deflections in the following cases : • Fully sheeted walls, where the wall sheeting is resting on ground slab / beam. • Partially sheeted walls with block wall underneath where the bottom girt is resting on the block wall. • Partially sheeted walls with openings / block where the fully sheeted height with no openings below the eave strut is more than half the bay spacing, in such case the diaphragm action will be adequate to provide the vertical support. For the previous cases the eave strut are designed only to carry axial loads accumulated from roof bracing otherwise the eave strut is subjected to combined bending moment about major axis and axial from bracing system the allowable load carrying capacities are shown in table 5.29.

DM 03.10.00

5-35

ZAMIL STEEL BUILDINGS DESIGN MANUAL 5. Secondary members design

PEB DIVISION

Table 5.29 – Eave Strut Capacity Bay

Wind Vecocity

Eave Height

B (m)

V (km/hr)

H (m) 6 8 10 6 8 10 6 8 10 6 8 10 6 8 10 6 8 10 6 8 10 6 8 10 6 8 10

110

6.00

130

150

110

7.5

130

150

110

9.00

130

150

1. 2. 3. 4. 5.

Enclosed Building 180 ES 180 ES 20 25 Mw Pall Pall (kN-m) (kN) (kN) 1.22 75.5 109.9 1.35 71.7 106.0 1.46 68.7 102.7 1.81 59.2 92.7 1.99 54.7 88.0 2.13 51.2 84.2 2.49 42.9 75.4 2.73 37.9 70.0 2.92 33.8 65.6 1.91 40.5 64.4 2.11 37.2 61.0 2.28 34.5 58.2 2.83 26.0 49.2 3.10 22.0 45.0 3.33 18.7 41.6 3.89 11.2 33.5 4.26 6.50 28.5 4.56 2.60 24.4 2.76 19.8 37.0 3.04 16.8 34.0 3.28 14.4 31.4 4.07 6.60 23.2 4.47 2.80 19.2 4.80 N.A 16.0 5.61 N.A. 8.5 6.13 N.A. 3.8 6.57 N.A. N.A.

Partially Enclosed Building 180 ES 180 ES 20 25 Mw Pall Pall (kN-m) (kN) (kN) 1.72 61.6 95.3 1.88 57.3 90.7 2.03 53.8 87.0 2.50 42.9 75.3 2.73 37.8 69.9 2.93 33.7 65.5 3.40 24.2 55.3 3.72 18.3 49.0 3.98 13.6 43.9 3.68 28.2 51.6 2.94 24.3 47.4 3.16 21.1 44.1 3.90 11.1 33.4 4.27 6.3 28.4 4.57 2.5 24.3 5.32 N.A. 14.8 5.81 N.A. 8.9 6.22 N.A. 4.1 3.86 N.A. 25.3 4.24 N.A. 21.5 4.56 N.A. 18.4 5.61 N.A. 8.4 6.14 N.A. 3.7 6.58 N.A. N.A. 7.66 N.A. N.A. 8.36 N.A. N.A. 8.95 N.A. N.A.

Open Building 180 ES 180 ES 20 25 Mw Pall Pall (kN-m) (kN) (kN) 0.86 87.6 122.5 0.95 84.3 119.1 1.03 81.7 116.3 1.30 73.4 107.7 1.43 69.5 103.6 1.54 66.4 100.4 1.81 59.3 92.8 1.98 54.8 88.1 2.13 51.3 84.3 1.34 50.9 75.1 1.49 48.1 72.3 1.61 45.9 70.0 2.02 38.7 62.5 2.23 35.3 59.0 2.40 32.5 56.1 2.82 26.1 49.3 3.10 22.1 45.1 3.33 18.8 41.6 1.93 29.1 46.7 2.14 26.7 44.1 2.32 24.6 42.0 2.91 18.2 35.3 3.21 15.1 32.1 3.46 12.5 29.4 4.06 6.6 23.2 4.46 2.9 19.3 4.79 N.A. 16.1

Building is enclosed, Gcp - 1.2; partially enclosed building, Gcp = 1.6; open building Gcp = 0.9 Roof angle a < 10. First purlin is at a distance of 900 mm from eave. Design is as per AISI 1986. The allowable stresses have been increased by 33% due to wind.

NOTATION: B = V = H =

Bay spacing (m) Wind speed (kph) Eave height (m)

Mw Pall

= =

Allowable Bending moment for wind uplift (kN.m) Allowable axial load (kN)

5.2.4.3. Eave Strut Connections: STIFFENER PLATE (2)-M12 x 35mm HSB EACH END

(2)-M12 x 35mm HSB EACH END

DETAIL #8

DETAIL #7 Shear Capacity: 43.5kN Standard Eave Strut

DM 03.10.00

Shear Capacity: 87.1kN Eave Strut w/ Shear Plate

5-36

ZAMIL STEEL BUILDINGS DESIGN MANUAL 6. End walls Design

PEB DIVISION

CHAPTER 6: END WALLS DESIGN 6.1. Post & Beam Endwall Rafters All end wall rafters are designed as simple beams over the endwall posts. They are comprised of: • "C" or double "C" cold-formed sections refer to tables (---) or • Built-up sections or • Hot rolled sections

Table 6.1. Hot Rolled Sections Dimensions DESCRIPTION

WEIGHT Kg/M

DEPTH cm

AREA 2 cm

FLANGE WIDTH cm

FLANGE THICK cm

WEB THICK cm

IPEA 200 x 18.4

18.4

19.7

23.5

10.00

0.70

0.45

UB 305 x 102 x 28

28.0

30.89

36.3

10.19

0.89

0.60

UB 406 x 140 x 39

39.0

39.73

49.40

14.18

0.86

0.63

DESCRIPTION

Ix 4 cm

Sx 3 cm

Rx cm

Iy 4 cm

Sy 3 cm

Ry cm

IPEA 200 x 18.4

1596

162.0

8.24

117.0

23.4

2.23

Section properties

UB 305 x 102 x 28

5421

351.0

12.2

157.0

30.8

2.08

UB 406 x 140 x 39

12452

626.9

15.90

411.0

58.0

2.89

DM 03.10.00

6-1

ZAMIL STEEL BUILDINGS DESIGN MANUAL 6. End walls Design

PEB DIVISION

6.1.1. Design Loads: i) Dead + Live ii) Dead + roof Wind suction 6.1.2. Design Concept Under gravity loads (Dead +Live) The top flange of the end wall rafters is under compression and it is braced against lateral torsional buckling at every purlin location. Under uplift loads (Dead +Wind) The bottom flange of the end wall rafters is under compression and it is unbraced against lateral torsional buckling. The buckling length is the distance between end wall columns, this may Significantly reduce the section bending capacity or flange braces are to be used. Another approach is to make use of the restraint tension flange (tension flange restraints spacing is arranged so that no torsional buckling failure mode is allowed). The following procedure was suggested by the BRITISH STANDARD (1). Compression flange lateral torsional buckling length is reduced according to the following formula:-

LYR = (nt .u.vt ).LY

  4a / hs vt =  2 2  1 + (2a / hs ) + 0.05(λ / x) 

0.5

Where :LYR: Reduced lateral buckling length. nt : The slenderness correction factor depending on the shape of moment = 0.928 for case of simple beam under uniform loads(2) u : Buckling parameter a : hs : x : D : TF : λ : LY : rY :

= 0.9 for hot rolled section = 1.0 for Built-up sections The distance between the axis of roof purlins and end wall rafter axis The distance between shear centers of flanges = (D – TF) Torsion index = D/TF Section depth. Flange thickness. LY/rY Lateral buckling length = distance between end wall columns Radius of gyration of buckling about the minor axis

Example :- end wall rafter IPEA 200 , COLUMN SPACING 600cm : LYR = 0.928*0.9*0.56*600 = 280.6cm

(1) (2)

Structural use of steel work in buildings BS 5950-1:2000 part 1 Annex (G) For general formula refer to G.4.3 of the above reference

DM 03.10.00

6-2

ZAMIL STEEL BUILDINGS DESIGN MANUAL 6. End walls Design

PEB DIVISION

Simplified method:Finite element study was performed to determine the effective unsupported length of the compression flange for the previous example using roof purlins spacing 170Cm, the study results gives LYR =272 cm which means that the BS 5950 formula are slightly conservative. For end wall beam commonly used cross section IPEA 200 LYR (compression flange lateral buckling) = Roof Purlin Spacing * 1.6 6.1.3. End Wall Rafter Guide Design Tables Table 6.2. End Wall Rafter Design - Built-Up sections End Bay 6.0m Span (m)

7.5m

9.0m

Wind Speed (kph) 110

130

150

110

130

150

110

130

150

2

Wind Pressure, q (kN/m ) 0.56

0.78

1.04

0.56

0.78

1.04

0.56

0.78

1.04

4.5

BUR1

BUR1

BUR1

BUR1

BUR1

BUR1

BUR1

BUR1

BUR1

5.0

BUR1

BUR1

BUR1

BUR1

BUR1

BUR1

BUR1

BUR1

BUR1

5.5

BUR1

BUR1

BUR1

BUR1

BUR1

BUR1

BUR1

BUR1

BUR1

6.0

BUR1

BUR1

BUR1

BUR1

BUR1

BUR1

BUR1

BUR1

BUR1

6.5

BUR1

BUR1

BUR1

BUR1

BUR1

BUR1

BUR1

BUR1

BUR1

7.0

BUR1

BUR1

BUR1

BUR1

BUR1

BUR1

BUR1

BUR1

BUR1

7.5

BUR1

BUR1

BUR1

BUR1

BUR1

BUR1

BUR1

BUR1

BUR2

8.0

BUR1

BUR1

BUR1

BUR1

BUR1

BUR2

BUR1

BUR1

BUR3

8.5

BUR1

BUR1

BUR1

BUR1

BUR1

BUR2

BUR1

BUR1

BUR4

9.0

BUR1

BUR1

BUR2

BUR1

BUR1

BUR3

BUR1

BUR2

BUR4

Legend Section

Description

Weight (kg/m)

BUR1

Built Up Rafter: 200 x 4 Web + 125 x 5 Flange

16.1

BUR2

Built Up Rafter: 200 x 4 Web + 125 x 6 Flange

18.1

BUR3

Built Up Rafter: 200 x 4 Web + 150 x 6 Flange

20.4

BUR4

Built Up Rafter: 200 x 4 Web + 150 x 8 Flange

25.1

Assumptions 1. The wind load has been applied in accordance with MBMA 1986 edition 1990 Supplement. Wind coefficients GCp = -1.3 as per MBMA table 5.7(a) 2. Maximum deflection was limited to span / 180. 3. The design has been made in accordance with AISI August 19, 1986 Edition with 11, 1989 addendum (2nd printing Nov. 1993) for Cold Formed Sections and AISC 1989 for Built-Up and Hot Rolled sections. 2 4. Yield strength of all material is assumed to be 34.5 kN/cm . An increase of 33% on the allowable stresses was considered as allowed by AISI and AISC specifications for wind load application. 5. All the rafters are considered braced at a maximum spacing of 1500 mm at the top flange. 6. Fully Enclosed Building condition has been assumed. 7. Rafter members are assumed as simply supported. 2 2 8. Gravity loads include Live load of 0.57kN/m and Dead Load of 0.1 kN/m (excluding self weight of rafter)

DM 03.10.00

6-3

ZAMIL STEEL BUILDINGS DESIGN MANUAL 6. End walls Design

PEB DIVISION

Table 6.3. End Wall Rafter Design - Cold formed Section End Bay 6.0m

7.5m

Span (m)

9.0m

Wind Speed (kph) 110

130

150

110

130

150

110

130

150

2

Wind Pressure, q (kN/m ) 0.56

0.78

1.04

0.56

0.78

1.04

0.56

0.78

4.5

200C25

200DC20

200DC25

200DC20

200DC25

300DC20

200DC20

200DC25

5.0

200DC20

200DC25

300DC20

200DC20

200DC25

200DC25

300DC20

5.5

200DC20

200DC25

200DC25

300DC20

200DC25

6.0

200DC25

300DC20

200DC25

6.5

200DC25

7.0

300DC20

7.5

300DC20

1.04

300DC20

300DC20

Legend Section

Description

Weight (kg/m)

200C25

]200x85x2.5

7.64

200DC20

][200x85x2.0

12.22

200DC25

][200x85x2.5

15.28

300DC20

][300x85x2.0

15.60

Assumptions 1. 2. 3. 4. 5. 6. 7. 8.

The wind load has been applied in accordance with MBMA 1986 edition 1990 Supplement. Wind coefficients GCp = -1.3 as per MBMA table 5.7(a) Maximum deflection was limited to span / 180. The design has been made in accordance with AISI August 19, 1986 Edition with 11, 1989 addendum (2nd printing Nov. 1993) for Cold Formed Sections and AISC 1989 for Built-Up and Hot Rolled sections. 2 Yield strength of all material is assumed to be 34.5 kN/cm . An increase of 33% on the allowable stresses was considered as allowed by AISI and AISC specifications for wind load application. All the rafters are considered braced at a maximum spacing of 1500 mm at the top flange. Fully Enclosed Building condition has been assumed. Rafter members are assumed as simply supported. 2 2 Gravity loads include Live load of 0.57kN/m and Dead Load of 0.1 kN/m (excluding self weight of rafter)

DM 03.10.00

6-4

ZAMIL STEEL BUILDINGS DESIGN MANUAL 6. End walls Design

PEB DIVISION

Table 6.4. End Wall Rafter Design – Hot rolled Section End Bay 6.0m

7.5m

Span

9.0m

Wind Speed (kph)ff

(m)

110

130

150

110

130

150

110

130

150

2

Wind Pressure, q (kN/m ) 0.56

0.78

1.04

0.56

0.78

1.04

0.56

0.78

1.04

4.5

HR1

HR1

HR1

HR1

HR1

HR1

HR1

HR1

HR1

5.0

HR1

HR1

HR1

HR1

HR1

HR1

HR1

HR1

HR1

5.5

HR1

HR1

HR1

HR1

HR1

HR1

HR1

HR1

HR1

6.0

HR1

HR1

HR1

HR1

HR1

HR1

HR1

HR1

HR1

6.5

HR1

HR1

HR1

HR1

HR1

HR1

HR1

HR1

HR1

7.0

HR1

HR1

HR1

HR1

HR1

HR1

HR1

HR1

HR1

7.5

HR1

HR1

HR1

HR1

HR1

HR1

HR1

HR1

HR2

8.0

HR1

HR1

HR1

HR1

HR1

HR2

HR1

HR1

HR2

8.5

HR1

HR1

HR1

HR1

HR1

HR2

HR1

HR2

HR2

9.0

HR1

HR1

HR2

HR1

HR1

HR2

HR2

HR2

HR2

Legend Section

Description

Weight (kg/m)

HR1

Hot Rolled Section: IPE 200 A

18.4

HR2

Hot Rolled Section: UB 305 x 102 x 28

28.0

HR3

Hot Rolled Section: UB 406 x 140 x 39

39.0

Assumptions 1.

The wind load has been applied in accordance with MBMA 1986 edition 1990 Supplement.

Wind coefficients GCp = -1.3 as

per MBMA table 5.7(a) 2. 3.

Maximum deflection was limited to span / 180. The design has been made in accordance with AISI August 19, 1986 Edition with 11, 1989 addendum (2nd printing Nov. 1993) for Cold Formed Sections and AISC 1989 for Built-Up and Hot Rolled sections.

4.

2

Yield strength of all material is assumed to be 34.5 kN/cm . An increase of 33% on the allowable stresses was considered as allowed by AISI and AISC specifications for wind load application.

5.

All the rafters are considered braced at a maximum spacing of 1500 mm at the top flange.

6.

Fully Enclosed Building condition has been assumed.

7.

Rafter members are assumed as simply supported.

8.

Gravity loads include Live load of 0.57kN/m and Dead Load of 0.1 kN/m (excluding self weight of rafter)

DM 03.10.00

2

2

6-5

ZAMIL STEEL BUILDINGS DESIGN MANUAL 6. End walls Design

PEB DIVISION

6.2. Endwall Posts All endwall posts are flush with the endwall structural line in end post&beam gable type and they are supporting end wall rafters. In all cases end wall posts are oriented so that end wall wind pressure is producing bending moments about the column major axis. Endwall posts are comprised of:

i) "C" or Double "C" cold-formed sections or ii) Built-up sections or iii) Hot rolled sections (table 6.1.) 6.2.1. Design Loads: i) End wall wind pressure (compression or suction) ii) Roof (Dead + Live) for end post & beam walls only iii) Roof (Dead + wind) for end post & beam only 6.2.2. Design Concept End wall posts are the supporting elements for end wall girts/block walls for wind loads (pressure or suction) which produce bending moment about posts major axes, end wall posts are designed as simple beam supported at foundation level (base plate) and are connected with Spanner(1) at roof purlins level. For Post & Beam end walls additional vertical loads from end wall rafters are transmitted to posts producing axial loads (compression or tension). End wall post buckling length about major axis is the column length(2) Flanges unsupported length is depending on the end wall type and position as follows:1) Sheeting with flush end wall girts Outer flanges unbraced length is the girt spacing. Inner flange unbraced length:Column web depth

No flange braces

≤ 200mm

Girt spacing

200mm – 350mm

1.6* Girt spacing

> 350mm

With flange braces

Notes

Flange brace spacing

Whichever is smaller

Flange brace spacing

2) Sheeting with by pass end wall girts Outer flanges unbraced length is the girt spacing Inner flange unbraced length:Column web depth

No flange braces

With flange braces

Notes

≤ 200mm

1.6* Girt spacing

Flange brace spacing

Whichever is smaller

> 200mm

Flange brace spacing

(1)

Spanners are cold formed C-sections connecting the end wall post with the two adjacent roof purlins thus transmitting the force to roof bracing (2) For the cases when end bay RC mezzanine Floor are supported on the end wall posts the column is considered braced at this point and the buckling length is depending on the segments lengths.

DM 03.10.00

6-6

ZAMIL STEEL BUILDINGS DESIGN MANUAL 6. End walls Design

PEB DIVISION

3) Block wall flush with column When designing an endwall that is called out on the C.I.F. as "open for block work" and flush with columns design the column as braced at standard girt clip locations and add the following note. “Contractor has to tie block work to wind columns at intervals not exceeding stability and wind column bracing.”

mm for lateral

Outer flanges unbraced length is the Clip spacing. Inner flange unbraced length:Column web depth

Unbraced length

≤ 200mm

Clip spacing

200mm – 350mm

1.6* Clip spacing

> 350mm

Unbraced within wall height

4) Block wall by bass with column Outer & inner flanges are considered unbraced within wall height.

Notes on endwall design •

For endwall columns that have to be designed for loading due to structural accessories such as mezzanines, lean-to, canopies, etc., built-up or hot-rolled columns must be used.



Wind columns sections having depths more than 300mm interfere with the rigid frame rafter in case a standard distance of 385mm is maintained from endwall steel line to center of rigid frame for a rigid frame end. In this situation we must keep the column top depth 200mm within the rafter zone. The following sketch shows the detailing procedure for the case of built-up section and hot rolled sections.

UB 305 OR UB406

BUILT-UP SECTION

HOTROLLED SECTIONS

END WALL COLUMNS WITH DEPTHS > 300mm

DM 03.10.00

6-7

ZAMIL STEEL BUILDINGS DESIGN MANUAL 6. End walls Design

PEB DIVISION

6.2.3. End Wall Posts Guide Design Tables Table 6.5. Allowable End Post Heights Cold Formed Section mm ]200x85x2.0 ]200x85x2.5 ][200x85x2.0 ][200x85x2.5 ][300x85x2.0 * ][300x85x2.5 * ][300x85x3.0 * ][300x100x3.0 * ][300x100x4.0 * ][400x125x3.0 * ][400x125x4.0

Weight Kg/m 6.11 7.64 12.22 15.28 15.60 19.43 23.32 25.20 33.60 33.20 44.28

Hot Rolled Section mm IPE 200 A UB 305x102x28 UB 406x140x39

Weight Kg/m

Built Up Section mm W200x4 F125x5 W200x4 F125x6 W200x4 F150x6 W200x4 F150x8 W200x4 F175x8 W300x4 F125x6 W300x4 F150x6 W400x4 F150x6 W400x4 F175x6

Weight Kg/m

18.40 28.00 39.00

16.09 18.05 20.41 25.12 28.26 21.20 23.55 26.69 29.10

Allowable Endwall Post Heights (in m) Wind Speed 110 kph Wind Speed 130 kph Spacing Spacing 4.5 6.0 7.5 9.0 4.5 6.0 7.5 9.0 5.9 5.2 4.8 4.4 5.1 4.5 4.1 3.8 6.7 5.9 5.3 4.9 5.7 5.1 4.6 4.2 8.0 7.1 6.4 5.9 7.0 6.1 5.6 5.1 8.5 7.8 7.2 6.7 7.7 6.9 6.2 5.7 10.5 9.3 8.4 7.8 9.1 8.0 7.3 6.7 11.5 10.5 9.5 8.8 10.3 9.1 8.2 7.6 12.1 11.1 10.4 9.6 10.9 9.9 9.0 8.3 12.6 11.6 10.8 10.2 11.4 10.4 9.8 9.1 13.7 12.5 11.7 11.1 12.4 11.3 10.6 10.0 16.3 14.9 14.0 13.2 14.7 13.5 12.4 11.4 17.7 16.2 15.2 14.3 16.0 14.7 13.7 13.0

Wind Speed 160 kph Spacing 4.5 6.0 7.5 9.0 4.3 3.8 3.4 3.2 4.8 4.2 3.8 3.5 5.8 5.1 4.6 4.3 6.5 5.7 5.2 4.8 7.6 6.7 6.1 5.6 8.6 7.6 6.9 6.3 9.3 8.2 7.5 6.9 10.0 9.0 8.2 7.6 10.9 10.0 9.2 8.5 12.9 11.4 10.3 9.5 14.1 12.9 11.9 11.0

Wind Speed 110 Km/h Spacing 4.5 6.0 7.5 9.0 9.3 8.5 7.7 7.1 13.4 11.9 10.8 10.0 17.3 15.8 14.8 14.0

Wind Speed 130 Km/h Spacing 4.5 6.0 7.5 9.0 8.3 7.3 6.6 6.1 11.7 10.3 9.4 8.6 15.6 14.3 13.4 12.4

Wind Speed 160 Km/h Spacing 4.5 6.0 7.5 9.0 6.9 6.1 5.5 5.1 9.8 8.6 7.8 7.2 13.8 12.3 11.2 10.3

Wind Speed 110 Km/h Spacing 4.5 6.0 7.5 9.0 9.2 8.4 7.9 7.5 9.7 8.9 8.3 7.9 10.1 9.2 8.6 8.2 11.1 10.1 9.5 9.0 11.6 10.7 10.0 9.4 12.7 11.7 10.9 10.3 13.2 12.1 11.3 10.7 16.0 14.6 13.7 12.9 18.0 16.5 15.4 14.6

Wind Speed 130 Km/h Spacing 4.5 6.0 7.5 9.0 8.3 7.6 7.1 6.7 8.8 8.0 7.5 7.1 9.1 8.3 7.8 7.4 10.0 9.2 8.6 8.1 10.5 9.6 9.0 8.5 11.5 10.5 9.6 8.9 11.9 10.9 10.2 9.6 14.4 13.2 12.1 11.2 16.2 14.9 13.9 13.2

Wind Speed 160 Km/h Spacing 4.5 6.0 7.5 9.0 7.3 6.6 6.0 5.6 7.7 7.1 6.5 6.0 8.0 7.4 6.9 6.5 8.8 8.1 7.5 7.1 9.3 8.5 7.9 7.5 10.0 8.8 8.0 7.4 10.5 9.6 8.7 8.0 12.6 11.1 10.1 9.3 14.3 13.1 12.3 11.3

Spanner Size 200C2.0 200C2.5 200C3.0

End Bay Purlin Size 200Z1.75 200Z2.0 29.9 29.9 30.7 35.1 30.7 35.1

200Z1.5 26.3 26.3 26.3

200Z2.5 29.9 38.0 43.8

Assumptions 1. The wind load has been applied in accordance with MBMA 1996 edition.

Wind coefficients for pressure GCp = 1.0 and

suction GCp = -1.0 as per MBMA table 5.7(a) for interior posts. 2. Maximum deflection was limited to height / 120. 3. The design has been made in accordance with AISI August 19, 1986 Edition with 11, 1989 addendum (2nd printing November 1993) for Cold Formed Sections and AISC 1989 for Built Up and Hot Rolled sections. 2

4. Yield strength of all material is assumed to be 34.5 kN/cm . An increase of 33% on the allowable stresses was considered as allowed by AISI and AISC specifications for wind load application. 5. All the columns are considered braced at a maximum spacing of 2250 mm. 6. Fully Enclosed Building condition is assumed. 7. (*) Not in stock sections

DM 03.10.00

6-8

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

6. End walls Design

6.3. End Wall Design Soft Ware Since endwall design for non-standard loading is not possible using the tables 6.2 - 6.5, an endwall design program is available. The salient features of this software are: a) b) c) d) e)

Wind loads are applied as per MBMA 1986 code Internal forces are calculated by structural analysis as simple span for all elements Cold-formed elements are designed in accordance with AISI 1986 Edition Built-up elements are designed in accordance with AISC 1989 Edition. All elements are considered to be fully braced in the lateral direction by purlins, girts or block wall.

This software allows the input on the following items: i)

ii) iii) iv)

v)

End Wall Condition: Post and Beam Endwall or Rigid Frame End Wall. In case of rigid frame EW condition corner columns are omitted and rafter is not considered. Only interior end wall columns are analyzed. Open Wall Condition: Fully enclosed or Partially Enclosed Condition. Appropriate GCp values are used. Rafter span has to be provided. Column heights are calculated automatically. Section profiles have to be provided either as cold-formed, built-up members or hot rolled members. Start with the least size and go for higher sizes in order to bring the unity checks close to 1.0 and deflection within limits by making red flags (!) disappear. Next page shows a sample design sheet for the endwall design. When this software is available, use it rather than tables.

DM 03.10.00

6-9

ZAMIL STEEL BUILDINGS DESIGN MANUAL 6. End walls Design

PEB DIVISION

End Wall Framing Design Sheet DL LL WL

0.10 0.57 1.00

kN/m2 kN/m2 kN/m2 7.00 6.00

Eave Height End Bay

Roof Slope Ridge Distance Enclosde Bldg Post & Beam End

0.50 : 10 30.00

m

2 1

1

m m

- Wind Loads are applied as per MBMA 1986 Edition with 1990 Supplement. - Internal Forces are calculated by structural analysis as Simple Span for all elements. - Cold Formed elements are designed in accordance with AISI 1986 Edition with 1989 Addendum. - Built-UP elements are designed in accordance with AISC 1989 Edition. - All elements are considered to be Fully Braced in the Lateral direction by purlins , girts or blockwall. Rafter Spans

7.00

7.00

7.00

7.00

7.00

7.00

7.00

7.00

7.00

7.00

Column Heights

Conc. Load kN

Control. Load Case

Internal Forces Shear Moment Axial kN kN.m kN

7.00

DC200X85X2.0

DL+WL

21.44

7

DC300X85X3.0

DL+WL

-23.89

7.35

DC300X85X2.5

DL+WL

47.27

14

DC300X85X3.0

DL+WL

-23.89

7.70

DC300X85X2.5

DL+WL

51.88

21

DC300X85X3.0

DL+WL

-23.89

8.05

DC300X85X3.0

DL+WL

56.70

28

DC300X85X3.0

DL+WL

-23.89

8.40

DC300X85X3.0

DL+WL

61.74

35

DC300X85X3.0

DL+WL

-23.89

8.25

DC300X85X3.0

DL+WL

59.55

42

DC300X85X3.0

DL+WL

-23.89

7.90

DC300X85X3.0

DL+WL

54.61

49

DC300X85X3.0

DL+WL

-23.89

7.55

DC300X85X2.5

DL+WL

49.88

56

DC300X85X3.0

DL+WL

-23.89

7.20

DC300X85X2.5

DL+WL

45.36

63

DC300X85X3.0

DL+WL

-23.89

6.85

DC300X85X2.5

DL+WL

41.06

70

DC300X85X3.0

DL+WL

-23.89

6.50

DC200X85X2.0

DL+WL

18.48

Cold Formed : Built -Up :

DM 03.10.00

Section

-13.65

-27.30

-27.30

-27.30

-27.30

-27.30

-27.30

-27.30

-27.30

-27.30

-13.65

Stress Ratios Mom. & Ax. Shear (Actual / Allowable)

Deflection @mid cm

12.25

0.97

0.18

5.48

-13.65

0.88

0.06

0.79

25.73

0.91

0.31

3.98

-13.65

0.88

0.06

0.79

26.95

0.99

0.32

4.79

-13.65

0.88

0.06

0.79

28.18

0.86

0.19

4.82

-13.65

0.88

0.06

0.79

29.40

0.94

0.20

5.71

-13.65

0.88

0.06

0.79

28.88

0.91

0.20

5.31

-13.65

0.88

0.06

0.79

27.65

0.83

0.19

4.47

-13.65

0.88

0.06

0.79

26.43

0.95

0.32

4.43

-13.65

0.88

0.06

0.79

25.20

0.87

0.30

3.66

-13.65

0.88

0.06

0.79

23.98

0.79

0.29

3.00

-13.65

0.88

0.06

0.79

11.38

0.84

0.17

4.08

C200X85X2.0 Single "C" - Depth: 200 mm , Flange 85mm ,Thickness: 2.0 mm DC300X100X2.5 Double "C" - Depth: 300 mm , Flange 100 mm , Thickness: 2.5 mm 200X3W+150X6F Depth: 200 , Web Thk: 3 , Flange Width: 150 , Flange Thk: 6 (All in mm)

6-10

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

6. End walls Design

6.4. Diaphragm Action at P&B End Walls Diaphragm action is the resistance to racking generally offered by the panels, fasteners and members to which they are attached. Diaphragm response to load, is dependent on several variables including panel configuration, type and spacing of fasteners, panel length, cover width, material strength, supporting frame work, the loading regime and diaphragm size. Diaphragm action can be explained for only flush mounted girt system. For exterior mounted girt system, the connection between girt and the main frame dictates the shear stiffness provided by the wall to the end frame. The strength of a diaphragm is defined as the ultimate load Pu. Ultimate strength is limited by any of the three possible failure mechanisms. One involves the longitudinal edge of a panel over the line, where force transfer is made at ends and from there to the structural system. The second case involves interior panels; particularly the imperfect interior panel to panel or side lap connections which are called “strut-like buckling” the third mode involves end fastener failure. 1. Fasteners Failures in Edge Members Su = Pu/L = [2α1 + np α2 + ne] Qf /L Where Su = Ultimate shear strength (kN/m) Pu = Ultimate load (kN) α1 = Σxi/w1: the end distribution factor per panel. α2 = Σxj/w1: Purlin distribution factor similar to α1 np = Number of purlins or joists excluding supports at panel ends. ne = Total number of edge connectors along the edge excluding those at the purlins and ends. L = Length of diaphragm (Diaphragm dimension parallel to the direction of load application) xi = Distance from panel centerline to any fastener xj = Distance of bolts in other direction Qf = Shear strength of sheet-to-frame connection. 2. Strut-like buckling: Su = [2 λ1 + np + nsαs + 4 Σ(xi/w1)2 + 2 np Σ(xj/w1)2] Qf/L Where λ1 = 1/{1+(Ls /135)2} : Strut-Like-Buckling Factor αs = Qf / Qs : Relative Fastner stiffness Ls = Purlin spacing w1 = Panel cover width ns = Number of side lap (stitch) connectors not at purlins (panel-to-panel only) Qs = Stitch connector strength

DM 03.10.00

6-11

ZAMIL STEEL BUILDINGS DESIGN MANUAL 6. End walls Design

PEB DIVISION

3. Fasteners failure in end members: Su = Qf / C1 Where, 1/ 2

2          a  2  L   C1 =   +  2   2  xj    x   n 1    2 + n p + α s n s + 4∑  i  + 2n p ∑       w1   w 1     

a = Diaphragm width n1 = Total number of end connectors over the section width ‘a’

Reference: “Steel Deck Institute, Diaphragm Design Manual First Edition” by Larry D. Luttrell Sponsored by “The Steel Deck Institute” Example: Shear Strength Evaluation Panel type : Type ‘A’ Steel length : L = 6m (236.2in) Number of purlins : 2 : 2m (78.7in) Purlin spacing Ls Covering width : 0.9m Number of sheet-sheet connectors along L : ns = 3 Test type : Diaphragm Sheet base-metal thickness : 0.5mm Diaphragm width ‘a’ : 1.8m (70.87in) Structural fasteners : SD5-5.5x25 SFS = 10 kN Qs = 10 kN Qf = (number of end connectors per sheet)(number of sheets)+1 = 7 n1 = 1.0 αs = 1/{1+(Ls/135)2} = 0.7462 λ1 = Σxi/w1 = 2.07 ; α2 = 2.07 α1

DM 03.10.00

6-12

ZAMIL STEEL BUILDINGS DESIGN MANUAL 6. End walls Design

PEB DIVISION

1. Fasteners failure in edge members: Su = (2x2.07+2x2.07+3) x10/6 = 18.8 kN/m 2. Strut like buckling: Su = {2x0.7462+2+3x1.0+4x4.28+2x2x4.28}x10/6 = 67.9 kN/m 3. Fastener failure in end members: 2  1.8  2  6   C1 =   +     7   2 + 2 + 1.0 x3 + 4x4.28 + 2x2x4.28  

1/ 2

= 0.295

Su = QF / C1 = 10/0.295 = 33.8 kN/m Least value is 18.8 KN/M for 1.8m wide diaphragm Factor of safety = 2 Allowable shear strength of 1.0m diaphragm = 18.8/(1.8x2) = 5.22 kN/m Zamil wall panels are properly fastened to the supporting structural units framing and are capable of resisting loads through in-plane shear resistance. This shear resistance is causing a shear transfer of these loads to the foundation with practically no deflection. The resistance of wall sheeting acting as a diaphragm is approximately 5.22 kN./m. The minimum effective lengths of sheeting required for a standard wind load of 1.0 kN/m2 are shown in the following table so as to eliminate sag rods and diagonals. The effective lengths shall be exclusive of any framed openings for accessories etc.

DM 03.10.00

6-13

ZAMIL STEEL BUILDINGS DESIGN MANUAL 6. End walls Design

PEB DIVISION

Table 6.6. Effective length of side wall sheeting (in meters) Width of Building (m)

4

5

6

7

8

9

6

2.3

2.8

3.4

3.9

4.5

5

9

3.4

4.2

5.1

5.8

6.8

7.5

12

4.6

5.6

6.8

7.8

9

10

15

5.7

7

8.5

9.8

11.3

12.5

18

6.9

8.4

10.2

11.7

13.5

15

Eave height (m)

Table 6.10. Effective length of end wall sheeting (in meters) End bay (m) 4.5 6 7.5

Eave height (m) 4 2.9 2.3 1.7

5 2.1 2.8 3.6

6 2.6 3.4 4.3

7 3 3.9 5

8 3.4 4.5 5.8

9 3.9 5 6.5

Explanation: If the eave height of the building is 6 m and the end bay of the building is 6 m, then the minimum sheeting length along the width of the building is 3.4m in each endwall column bay as per the second table. This is obtained as: (6/2)x1.0x6/5.22=3.4m

DM 03.10.00

6-14

ZAMIL STEEL BUILDINGS DESIGN MANUAL 7. Bracing system design

PEB DIVISION

CHAPTER 7: BRACING SYSTEM DESIGN Rigid frames offer no lateral resistance normal to their plane in the longitudinal direction of pre-engineered buildings, unless fixed at the base which is not a viable solution for most of the frames. Thus stability in longitudinal direction is achieved by bracing in roof and sidewall provided at certain bays. The main purpose of a bracing system is the transmission of lateral forces due to wind, crane, seismic, etc. to the column bases and eventually to the foundations. Zamil steel standard bracing systems are X bracings, and for special requirements portal bracings and minor axis bending are adopted. 7.1. Bracing Structural Types Three structural types of bracing are used X-bracing, portal bracing and Minor axes bending 7.1.1. X-bracing This is the standard bracing system commonly used in the roof and sidewalls of pre-engineered steel buildings. Materials used for the diagonals are galvanized cable strands, rods, and angles. Out of these, galvanized cable strand is very common. The distribution of forces in the roof bracing is elaborated in section 7.2. The force distribution from the eave to the sidewall bracing and to the foundation is explained in the following sketch. Horizontal Reaction H = P (force at eave) Vertical Reaction V = P x E / B In case the rod/cables get too long (12m-15m), sidewall bracing can be broken down as shown in the following sketch by means of a horizontal strut member. The reactions are calculated as: H=P V = P (E1+E2)/B Note: X-Bracing is designed to resist only tensile loads. Available Cable: ASTM A475 Class A Extra high strength cables are presently available in ½ inch (12mm) size with breaking load of 119.7kN. The allowable load is 60 kN obtained by using a factor of safety of 2 and an increase in load by 33% due to wind load considerations. Available Rods: ASTM A 572 Grade 36 rod is presently available in one size of 24mm with Fy=24.8kN/cm2 and Fu=40.0kN/cm2 ⇒ Ft = 0.33Fu =13.2kN/cm2. Tallowable = 79kN with obtained by increase the allowable tensile stress by 33% increase for wind forces considerations.

DM 03.10.00

7-1

ZAMIL STEEL BUILDINGS DESIGN MANUAL 7. Bracing system design

PEB DIVISION

7.1.2. Portal Bracing: This form of bracing is usually provided at the exterior side walls or between interior columns along the length of the building in very wide multispan and multigable buildings where diagonal 'X' bracing is not permitted due to a desire to have clear non-obstructed space. Columns and rafters used in portal frames are either built-up or hot rolled sections. Portal frame columns are directly stitch bolted to the web of the rigid frame columns and need not be anchored to the substructure. If head clearance requirement is not for the full available height, then Xbracing can be provided above portal bracing. If the difference between the portal frame and the eave is more than 2m, X-bracing has to be provided. If this difference is from 0.50m to 2.0m then a kicker angle is sufficient to transfer the horizontal load from eave strut to the portal frame. Portal frame should be designed with stitched flanges of column braced at stitched points while the other flanges unbraced. Rafter should be treated fully unbraced (both top & bottom flanges). (Use Cb for columns = 1.75 and Cb for rafter = 2.3 when the design code is AISC 89) Portal frame without X-bracing: Apply horizontal accumulated force P at eave to the portal frame as shown below: H1 = H2 = P/2 V1 = V2 = Ph/L

Portal frame with X-bracing: The distribution of horizontal force is shown in the sketch.

Tx = P =

TL L2 + h 12

Ty =

Th 1 L2 + h 12

The portal has to be designed for the following forces: H1 = H2 = P/2 V1 = Ph/L; V2 = Ph/L+Ty

DM 03.10.00

7-2

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

7. Bracing system design

7.1.3. Minor Axis Bending In this method the rigid frame columns are analyzed as fixed at the base in the minor axis direction so as to resist the lateral forces applied along the length of the building. This system is recommended generally for open structures with narrow widths, low eave heights and having a large number of bays. The lateral force along the eave of the building is divided by the total number of main frame columns, resulting in a small force per column that can be resisted by the section properties of the column about its weak axis. The design engineer should check for the horizontal sway of the frame in the longitudinal direction of the building. Minor axis bending becomes uneconomical and less suitable for enclosed buildings with greater widths, high eave height and smaller number of bays. This bracing system is most common in car canopies, which require walls to be fully open for access. Example: Consider a car canopy with the following data: Cross section area is as shown in the sketch: Wind Velocity Pressure: 1.4 Bay Spacing: 6 bays @ 6m ------------------------------A procedure outlined in MBMA 1996 Section 4 for open buildings should be followed: Number of rigid frames N = 7 Projected Area: Column area = 0.6x3 = 1.8m2 Rafter area = 0.45x6 = 2.7m2 As = Total Steel Projected Area = 4.5m2 AE = Total projected area outlined by frame = Width x Average Height = 6x3=18m2 ϕ = Solidity Ratio = As / AE = 4.5/18 = 0.25 GCp(0) = 1.45+0.43(1-ϕ) = 1.77 (Equation A4-17 of MBMA ’96 for 0.1< ϕ > 55.3kN 7.2. Bracing Systems Different bracing systems are required according to the applied loads on the building those systems are Wind Bracing, Seismic bracing and Crane bracing. 7.2.1. Wind Bracing 7.2.1.1. Longitudinal bracing: The wind load acting on the endwall is transmitted to the wind columns by sheeting and girts. The columns then transmit the wind force equally to their bases and to the building roof. The force transmitted to building roof travels in the roof through purlins, instantaneously gets divided equally in the braced bays, and eventually gets transferred to the sides of the building and down into the sidewall foundation. The following sketch illustrates the flow of wind loads in the bracing system:

In the above sketch, the rods shown in heavy lines are those acting (in tension) to resist the wind acting in the direction shown. When the wind reverses directions, the other rods, shown dashed, will act instead. Note that for the above example, the rods between grids C & D are assumed to take no load for whichever direction the wind is acting in. However, for the case where there is a load applied at the ridgeline of the building, these rods will act in tension. Note that all strut members and their connections, used in the end bays and braced bays, shall be designed for the axial loads shown on the above diagram. The standard end connections are (2 Nos.) 12 mm φ A307 bolts in purlins and (2 Nos.) 12 mm φ A325N bolts on eave struts with allowable shear loads of 22 kN and 47 kN (an increase of 33% for wind included) respectively. DM 03.10.00

7-4

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

7. Bracing system design

When the actual loads exceed these allowable loads, the connection shall be modified by: Either changing the A307 bolts to A325N bolts, or by Adding a clip, thus increasing the number of bolts resisting the axial load in shear, or by A similar method to increase the capacity of the connection. The various options are shown in the purlin connection details in clause 5.2.2.3. of this manual. Example 1: An example showing the generalized procedure for the computation of forces in bracing due to wind in an un-symmetrical building is presented. This method is based on the truss analogy assuming each braced bay acts like a truss as shown in the following sketch. Building Data: Building Width: 24m Eave Height (left): 6m Eave Height (right): 5.7m Slope (left): 0.5 to 10 Slope (right): 1.0 to 10 Ridge Distance (from left): 14m No. of braced bays: 2 Wind Pressure: 0.7 Bay Spacing: 7.5m Ridge Height: 6.7m

Step 1: Calculate the tributary area associated for each column Tributary area for corner column = 6.075x3 = 18.225m2 Tributary area for 1st interior column = 6.3x6 = 37.8m2 and so on.

Step 2: Calculate the force transmitted to each braced bay at the location of column lines. With n = Nos. of braced bays =2 Force at corner column = 0.7x18.225/(2n) = 3.189 kN Force at 1st interior column = 0.7x37.8/(2n) = 6.615 kN and so on. Step 3: Calculate reactions at both ends using the forces using moment and force equilibrium equations. DM 03.10.00

7-5

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

7. Bracing system design

Reaction @ right = (3.071x24 + 6.615x18 + 6.917x12 + 6.615x6)/24 = 13.145 kN Reaction @ left = 3.189 + 6.615 + 6.917 + 3.071 – 13.14 = 13.262 kN Step 4: Draw shear force diagram using the forces and reactions The shear force at each column location indicates the axial force in the strut purlin at that location. This force is distributed to the bracing cable/rod. Step 5: Calculate cable/rod force: Length of rod in the 1st bay = √(7.52+6.0072) = 9.61m Bracing force in 1st bay = axial force x length of cable/bay spacing = 10.073x9.61/7.5 = 12.91kN Bracing force in 2nd bay = 3.458x9.61/7.5 = 4.43 kN Bracing force at ridge (left) = 3.458x7.76/7.5 = 3.58 kN Bracing force at ridge (right) = 3.458x8.51/7.5 = 3.92 kN Bracing force in last bay = 10.073x9.62/7.5 = 12.93 kN Step 6: Calculate cable/rod force of left sidewall: Cable/rod length = 9.6m Bracing force = 13.262x9.6/7.5 = 16.975 kN Similarly Calculate cable/rod force of right sidewall: Cable/rod length = 9.42m Bracing force = 13.145x9.42/7.5 = 16.51 kN Step 7: Calculate the bracing force transmitted to foundations. Horizontal Reaction H @ near side wall = P (force at eave) = 13.262kN Vertical Reaction V @ near side wall = P x E / B = 13.262x6/7.5=10.61kN Where, E = Eave Height and B = Bay spacing Horizontal Reaction H @ far side wall = P (force at eave) = 13.145kN

DM 03.10.00

7-6

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

7. Bracing system design

Vertical Reaction V @ near side wall = P x E / B = 13.145x5.7/7.5=10.0kN Simplified Bracing calculations for Symmetric Frames: A much simplified procedure may be adopted for a symmetric frame and bracing pattern. The following example elaborates this procedure. Example 2: The computation of forces in bracing due to wind in a symmetrical building is presented. This method is based on the truss analogy assuming each braced bay acts like a truss as shown in the following sketch. Building Data: Building Width: 24m Eave Height: 6m Slope: 1.0 to 10 No. of braced bays: 2 Wind Pressure: 0.7 Bay Spacing: 7.5m Step 1: Calculate the tributary area associated for each column Tributary area for corner column = 6.15x3 = 18.45m2 Tributary area for 1st interior column = 6.6x6 = 39.6m2 and so on. Step 2: Calculate the force transmitted to each braced bay at the location of column lines. With n = Nos. of braced bays =2 Force at mid column = 0.7x39.6/(2x2)=6.93 kN Force on either side of ridge P1 = 3.7kN Force at 1st interior column P2 = 0.7x39.6/(2x2) + P1 = 10.63 kN Force at corner column P3 = 0.7x18.45/(2x2) + P2 = 13.86 kN

DM 03.10.00

7-7

ZAMIL STEEL BUILDINGS DESIGN MANUAL 7. Bracing system design

PEB DIVISION

Step 3: Calculate cable/rod force: Length of cable in the 1st bay = √(7.52+6.032) = 9.623m Bracing force F1 = 3.7x9.623/7.5 = 4.75 kN Bracing force F2 = 10.63x9.623/7.5 = 13.64 kN Step 4: Calculate cable/rod force of sidewalls: Cable/rod length = 9.6m Bracing force F3 = 13.86x9.6/7.5 = 17.74 kN Step 5: Calculate the bracing force transmitted to foundations. Horizontal Reaction H = P (force at eave) = 13.86kN Vertical Reaction V = P x E / B = 13.86x6/7.5=11.09kN Where, E = Eave Height and B = Bay spacing 7.2.1.2. Transversal bracing in P&B end walls Wind bracing is required in by-framed P&B endwalls in the absence of diaphragm action. Bracing is designed for the portion of wind force acting on the sidewall on half end bay width. This transverse lateral force is transmitted to the endwall rafter as an axial force and then back to an endwall post foundation through a brace rod placed in the plane of the endwall. P = Transverse lateral load = = q x GCp x h x B / 4n Where, GCp = 0.5+0.7 = 1.2 @ End Zone (Table 5.4a of MBMA 1996) B = Side Wall End Bay h = peak height S = endwall braced bay spacing n = number of braced bay Horizontal Reaction at column: H = P; Vertical Reaction V = P h / S Tension in the rod

T = P

h

2

+ S S

2

Note that the other brace rod, shown in a dashed line above, acts whenever the wind reverses directions. DM 03.10.00

7-8

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

7. Bracing system design

7.2.2. Seismic Bracing The seismic loads applied in the longitudinal direction of the building are computed as per MBMA code unless otherwise is required by the customer and stated in the (C.I.F.). The forces at roof for each wind column influence area are calculated. The distribution of seismic forces in the roof bracing should be made exactly as shown for wind forces. The following sketch illustrates the flow of seismic loads in the roof bracing:

Note: Wind and seismic loads should not be combined. 7.2.2.1.Sidewall bracing X-bracing In the absence of mezzanine floors, only accumulated roof bracing load at eave needs to be transferred to the wall bracing in a manner similar to wind bracing. Horizontal Reaction H = P (force at eave) Vertical Reaction V = P x E / B Tension in the wall bracing cable = P x Cable Length / Bay Spacing Sidewall bracing may include the seismic forces at mezzanine floor levels if the building has mezzanine. In this case an additional seismic force at mezzanine level should be added and no strut member is required since the mezzanine beam/joist acts like a strut member. The reactions are calculated as: H = P+F1 V = [P (E1+E2) + F1 x E2]/B

DM 03.10.00

7-9

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

7. Bracing system design

7.2.2.2.Sidewall bracing Portal Bracing At interior mezzanine column locations portal bracing is often required in certain bays to resist the seismic forces pertaining to the tributary area of that mezzanine column in longitudinal direction. The portal has to be designed for seismic force F per braced bay at mezzanine level. For 2 level mezzanine building the portal frame can be designed with mezzanine beam/joist for forces as shown below:

F1 = Force at 1st Mezzanine Level F2 = Force at 2nd Mezzanine Level

DM 03.10.00

7-10

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

7. Bracing system design

7.2.3. Crane Bracing 7.2.3.1 Top Running The longitudinal load travels through the runway beam until it reaches a braced bay. Once there, it is transferred in compression through a diagonal angle and directly to the vertical bracing system comprised of rods, angles or portal frames. This eliminates the need for a strut beam. The following sketches illustrate the bracing slot locations.

The lower rods/angles/portal are designed for longitudinal crane force per braced bay in addition to the accumulated wind force carried over from the roof. The reactions are calculated as: H = P+F V = [P (E1+E2) + FxE2]/B Tension in rod/angle T = (P+F)x Rod Length/B

DM 03.10.00

7-11

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

7. Bracing system design

Important Notes: • Note that in case of portal bracing, portal rafter is provided at the location of lower rod slots. •

Diagonal angles are connecting top flange of the crane beam (in the level of crane longitudinal force) with rigid frame column from both direction in order to transmit the crane longitudinal force from the crane beam to vertical bracing system. These angles are provided at every rigid frame column to prevent buckling of column at these positions as shown in the sketch above.



In lieu of a crane bracket if a separate crane column or frame supports the runway beam, then brace rods or angles may be used in the plane of the runway beam thus eliminating the need of the diagonal angle mentioned above.

7.2.3.2 Underhung i) Longitudinal bracing: The longitudinal load in a runway beam of an underhung crane is transmitted through vertical rods or angles to the roof of the building. Once the load reaches the roof, it is carried to the sidewall foundations through the roof bracing system.

Note: Always provide a flange brace on either side of bracket from purlin closest to crane bracket. ii)

Lateral Bracing:

Case 1 If the underhung crane bracket is less than 500 mm in length, then no lateral bracing is required. The lateral load induced in the runway beam is transmitted to the rigid frame rafter through bending in the bracket.

DM 03.10.00

7-12

ZAMIL STEEL BUILDINGS DESIGN MANUAL 7. Bracing system design

PEB DIVISION

Forces induced in the rafter are: Horizontal Force H and Moment M = He Case 2 On the other hand, when the underhung crane bracket is 500 mm or more in length, angles are used to transmit the lateral crane load to the frame rafter: Note that two loads (each equal to H) shall be applied to the frame rafter as shown when designing the frame. Also note that the bracing angle should be designed to take compression or tension.

Case 1

Case 2

7.3. Bracing Design Notes 1. Wind and Seismic forces should not be combined and shall be worked out independently. 2. When deign of bracing system subjected to both wind&crane loads is performed according to (AISC ASD 1989), Only the following load combinations(1) to be checked :• crane load (without 1.333 increase to allowable loads) • wind load (with 1.333 increase to allowable loads) • crane + 0.5 wind (with 1.333 increase to allowable loads). 3. For crane bracing system the breaking force should not be divided between braced bays along the crane line but to be applied totally on one bay to account for cases when the crane bridge is directly loaded in the a braced bay.

(1)

Unless otherwise is required by customer

DM 03.10.00

7-13

ZAMIL STEEL BUILDINGS DESIGN MANUAL 8. Cranes systems design

PEB DIVISION

CHAPTER 8: CRANE SYSTEMS DESIGN Cranes in industrial buildings are used to improve material handling productivity and to allow more efficient utilization of space by reducing or eliminating traffic due to forklifts etc. The most common types of Crane Systems in pre-engineered steel buildings are: 1) 2) 3) 4)

Top-running Under-hung cranes / Monorails JIB cranes Gantry & Semi-gantry cranes

8.1. Cranes Systems Design Rules: The following are assumptions, rules and limitations made when designing crane support components: 1. Runway beam is simply supported. 2. One or two cranes may act per bay (as specified by customer). If two cranes act per bay, the design engineer shall obtain the necessary information from the customer specifying the minimum possible distance between the wheels of the separate cranes. If this information cannot be obtained from the customer, then the Design Engineer shall assume this data as shown in the latest available Morris catalog. This information must be shown in the calculation sheets and on drawings. 3. Generally, four wheels are considered per crane (2 at each end). 4. Cranes are either cab operated (25% vertical impact), or pendant operated (10% vertical impact). Unless it is clearly specified that the crane is cab operated, the Design Engineer shall assume it to be pendant operated. 5. All top-running crane runway beams are built-up sections with cap channels. All under-hung crane runway beams are hot rolled sections generally are not in the Zamil Steel scope of supply. Only the flange of the beam supporting the crane wheels resists the lateral loads induced by the operation of the crane. This includes the cap channels for top running cranes. 6. The cap channel shall be directly welded on both sides to the web of the runway beam, without the top flange. 7. If a shop splice is needed on runway beam it shall be located at a distance not to exceed 1/4 span from either end of beam. 8. Refer to clause 3.9 for the guide lines to be considered while choosing the crane structural system Refer to clause 2.4 for serviceability consideration.

DM 03.10.00

8-1

ZAMIL STEEL BUILDINGS DESIGN MANUAL 8. Cranes systems design

PEB DIVISION

8.2. Different Crane Types 8.2.1. Top Running Cranes 8.2.1.1. Bracket System

eb P

COLUMN WEB STIFFNERS (N.S & F.S)

b M

a c

RIGID FRAME COLUMN

TYP TYP BRACKET WEB STIFFNER (N.S & F.S)

d TYP

CRANE BEAM BRACKET

e

Main frame column Moment, M = P.e Maximum bracket moment, M = P.eb Maximum bracket shear, V = P The bracket shall have end stiffeners welded to the top flange, bottom flange, and web located beneath the centerline of the runway beam. The welds (to top flange and web) on the stiffener shall be designed to transmit the vertical load P. The welds on the bracket flanges to the column shall be full strength welds. The weld on the bracket web to the column flange shall be designed to transmit the shear force V. Typically, the following bracket sections shall be used whenever possible. P (kN)

Bracket Size

Flanges (mm x mm)

tweb (mm)

depth (mm)

Stiffener N.S.&F.S. (mm x mm x mm)

a (mm)

b (mm)

c (mm)

d (mm)

UPTO 300

200x10W+ 500x8F

200x10

8

520

86x8x500

Full Strength Weld

8

5

Full Strength Weld

8.2.1.2.Connection for Lateral Load The lateral load on a crane runway beam is transmitted to the main frame column by means of a pair of angles connected to the top flange of the runway beam. Note that the connection has a capacity for a maximum lateral load of 45 kN governed by one 20mm φ A325N bolt in shear (considering the possibility of only one angle resisting the entire lateral load). Refer to clause 7.2.3.1 for the detailed sketch for crane/bracket arrangement.

DM 03.10.00

8-2

ZAMIL STEEL BUILDINGS DESIGN MANUAL 8. Cranes systems design

PEB DIVISION

8.2.1.3. Independent Crane Column Whenever an independent crane column is used, it is turned 90° with respect to the main frame column. The column is designed for an axial load equal to the maximum crane reaction at the frame line as well as an eccentric moment equal to 50% of the maximum reaction times half the column depth. It is tied back to the main frame column, which provides it with bracing against axial buckling in the weak direction. These bracing elements are normally connected to the crane column web at one end and to the main frame column flange at the other end. For optimum spacing, the braces shall be placed at intervals Ly where, Ly = Lx (ry/rx)

DM 03.10.00

[Note that Kx = Ky = 1.0]

8-3

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

8. Cranes systems design

8.2.1.4. Stepped Column The use of a separate crane column shall be limited to eave heights less or equal to 15m beyond which a stepped crane column becomes the only option. Note that the stepped crane column should always require a fixed base.

DM 03.10.00

8-4

ZAMIL STEEL BUILDINGS DESIGN MANUAL 8. Cranes systems design

PEB DIVISION

8.2.1.5. Crane Tower The "Crane Tower" frame is a frame, normally used to support the crane steel, which extends past the building framework. It is comprised of a truss with "H" columns as the chords and angles as the diagonal members.

Case (a) R1 = H R2 = Hh/B R3 = R2 + P

Case (b) R1 = H R2 = Hh/B R3 = P - R2

The axial load in horizontal and diagonal members may be easily obtained by the joint method of analysis. A typical crane tower is presented which is designed for the following loading. Crane capacity: 25 T Bridge span : 30 m Beam span :9m Crane leg ht. :6m Crane type: Morris

DM 03.10.00

8-5

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

DM 03.10.00

8. Cranes systems design

8-6

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

DM 03.10.00

8. Cranes systems design

8-7

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

8. Cranes systems design

8.2.1.6. Crane Beam Design Crane beams are designed as simple beams using ASFAD (Crane Beam Input-CBDA). The input contains sizes of beam section (hot-rolled / built-up) with cap channel, the crane data (Or direct straining actions) and design parameters. The crane data includes trolley weight, bridge weight, maximum static wheel load, vertical impact ratio, lateral kick ratio, longitudinal kick ratio as percentage, wheel base and bumper distance. This data can be obtained from crane manufacturer catalogues. In the absence of such a data Morris crane data should be used and mentioned in the design calculation package. The design parameters include beam span, un-braced length for top flange, effective wheel bearing length N, allowable fatigue stress range and the information about the end-bearing stiffener. The effective bearing length can be assumed as twice the depth of rail. The procedure for preparing the input for crane beam design program is outlined in Computer Aids Manual. The estimation of allowable fatigue stress range has been explained in Table 2.3 When using built-up crane beam it is recommended to limit web slenderness web ratio to 120 (hw/tw ≤120), design table 8.1 have been provided for standard spans and bridge span 15m, 18m and 20m for crane capacity ranging from 1 MT to 25 MT. This table will also provide a guideline for choosing an appropriate section that can be used in the input of CBDA program. Table 8.2 gives the reactions resulting from the design of crane beams that can be used as loads on the crane supporting rigid frames.

DM 03.10.00

8-8

ZAMIL STEEL BUILDINGS DESIGN MANUAL 8. Cranes systems design

PEB DIVISION

Table 8.1. – Built-Up Crane Beam with parallel flange cap channel MORRIS Cranes

Crane Beam Span (m)

Crane Bridge Span(m)

15

18

20

Crane Capacities(T) Single Girder Cranes 1

2

3.2

5

6.3

8

6

PFC200X75 ### 0X0 200X5 200X8 0.43

PFC200X75 ### 0X0 250X5 200X8 0.45

PFC200X75 ### 0X0 300X5 200X8 0.47

PFC200X75 # 0X0 350X5 200X8 0.49

PFC200X75 # 0X0 400X5 200X8 0.51

PFC200X75 ## 0X0 450X5 200X8 0.53

7.5

PFC200X75 ### 0X0 300X5 200X8 0.47

PFC200X75 ### 0X0 350X5 200X8 0.49

PFC200X75 # 0X0 350X5 200X8 0.49

PFC200X75 # 0X0 500X5 200X8 0.55

PFC260X75 ## 0X0 450X5 260X8 0.60

PFC260X75 ## 0X0 500X5 260X8 0.62

9

PFC200X75 ### 0X0 350X5 200X8 0.49

PFC200X75 ### 0X0 400X5 200X8 0.51

PFC260X75 # 0X0 400X5 260X8 0.58

PFC260X75 # 0X0 500X5 260X8 0.62

PFC260X75 ## 0X0 600X5 260X8 0.66

PFC380X100 ## 0X0 500X5 260X8 0.88

6

PFC200X75 ### 0X0 200X5 200X8 0.43

PFC200X75 ### 0X0 250X5 200X8 0.45

PFC200X75 ### 0X0 300X5 200X8 0.47

PFC200X75 # 0X0 350X5 200X8 0.49

PFC200X75 # 0X0 400X5 200X8 0.51

PFC200X75 ## 0X0 450X5 200X8 0.53

7.5

PFC200X75 ### 0X0 250X5 200X8 0.47

PFC200X75 ### 0X0 350X5 200X8 0.49

PFC200X75 # 0X0 350X5 200X8 0.49

PFC200X75 # 0X0 500X5 200X8 0.55

PFC260X75 ## 0X0 450X5 260X8 0.60

PFC260X75 ## 0X0 500X5 260X8 0.62

9

PFC200X75 ### 0X0 350X5 200X8 0.49

PFC200X75 ### 0X0 400X5 200X8 0.49

PFC260X75 # 0X0 400X5 260X8 0.58

PFC260X75 # 0X0 500X5 260X8 0.62

PFC260X75 ## 0X0 600X5 260X8 0.66

PFC380X100 ## 0X0 500X5 260X8 0.88

6

PFC200X75 ### 0X0 200X5 200X8 0.43

PFC200X75 ### 0X0 250X5 200X8 0.45

PFC200X75 ### 0X0 300X5 200X8 0.47

PFC200X75 # 0X0 350X5 200X8 0.49

PFC200X75 ## 0X0 400X5 200X8 0.51

PFC200X75 ## 0X0 450X5 200X8 0.53

7.5

PFC200X75 ### 0X0 300X5 200X8 0.47

PFC200X75 ### 0X0 350X5 200X8 0.49

PFC200X75 # 0X0 350X5 200X8 0.49

PFC200X75 # 0X0 500X5 200X8 0.55

PFC260X75 ## 0X0 450X5 260X8 0.60

PFC260X75 ## 0X0 500X5 260X8 0.62

9

PFC200X75 ### 0X0 350X5 200X8 0.49

PFC200X75 ### 0X0 400X5 200X8 0.51

PFC260X75 # 0X0 400X5 260X8 0.58

PFC260X75 # 0X0 500X5 260X8 0.62

PFC260X75 ## 0X0 600X5 260X8 0.66

PFC380X100 ## 0X0 550X5 260X8 0.90

NOTE: 1.

Fatigue Criteria (Loading Condition 2) is considered.

2.

Based on Pendent Operated Crane.

3.

Section Details: ( # = With No-Bearing Stiffener. ## = With Bearing Stiffener. ### = No Stiffener) Data Sequence: Cap Channel Top Flange Size (mm) Web Size (mm) Bottom Flange Size (mm) Weight (kN/m)

DM 03.10.00

Continued.....

8-9

ZAMIL STEEL BUILDINGS DESIGN MANUAL 8. Cranes systems design

PEB DIVISION

Table 8.1.(cont’d) – Built-Up Crane Beam with parallel flange cap channel MORRIS Cranes Crane Bridge Span(m)

15

18

20

Crane Beam Span (m)

Crane Capacities(T) Single Girder Cranes

Double Girder Cranes

10

12.5

16

20

25

6

PFC260X75 ## 0X0 450X5 260X8 0.60

PFC260X75 ## 0X0 500X6 260X8 0.66

PFC380X100 ## 0X0 450X6 260X8 0.90

PFC380X100 ## 0X0 450X8 260X8 0.97

PFC380X100 ## 260X8 500X8 260X8 1.16

7.5

PFC380X100 ## 0X0 450X5 260X8 0.86

PFC380X100 ## 0X0 500X6 260X8 0.92

PFC380X100 ## 0X0 550X6 260X8 0.94

PFC380X100 ## 0X0 600X8 260X8 1.06

PFC380X100 ## 260X8 650X8 260X8 1.25

9

PFC380X100 ## 0X0 550X5 260X8 0.90

PFC380X100 ## 0X0 600X6 260X8 0.97

PFC380X100 ## 0X0 750X8 260X8 1.15

PFC380X100 ## 0X0 850X8 260X8 1.21

PFC380X100 ## 260X8 800X8 260X8 1.34

6

PFC260X75 ## 0X0 400X5 260X8 0.58

PFC260X75 ## 0X0 450X6 260X8 0.64

PFC380X100 ## 0X0 450X8 260X8 0.97

PFC380X100 ## 0X0 450X8 260X8 0.97

PFC380X100 ## 260X8 500X8 260X8 1.16

7.5

PFC380X100 ## 0X0 450X5 260X8 0.86

PFC380X100 ## 0X0 500X6 260X8 0.92

PFC380X100 ## 0X0 550X8 260X8 1.03

PFC380X100 ## 0X0 600X8 260X8 1.06

PFC380X100 ## 260X8 700X8 260X8 1.28

9

PFC380X100 ## 0X0 550X5 260X8 0.90

PFC380X100 ## 0X0 500X6 260X8 0.97

PFC380X100 ## 0X0 700X8 260X8 1.12

PFC380X100 ## 0X0 850X8 260X8 1.21

PFC380X100 ## 260X8 850X8 260X8 1.37

6

PFC260X75 ## 0X0 450X5 260X8 0.60

PFC260X75 ## 0X0 450X6 260X8 0.64

PFC380X100 ## 0X0 450X8 260X8 0.97

PFC380X100 ## 0X0 450X8 260X8 0.97

PFC380X100 ## 260X8 500X8 260X8 1.16

7.5

PFC380X100 ## 0X0 450X5 260X8 0.86

PFC380X100 ## 0X0 550X6 260X8 0.94

PFC380X100 ## 0X0 550X8 260X8 1.03

PFC380X100 ## 0X0 600X8 260X8 1.06

PFC380X100 ## 260X8 650X8 260X8 1.25

9

PFC380X100 ## 0X0 550X5 260X8 0.90

PFC380X100 ## 0X0 650X6 260X8 0.99

PFC380X100 ## 0X0 750X8 260X8 1.15

PFC380X100 ## 0X0 850X8 260X8 1.21

PFC380X100 ## 260X8 850X8 260X8 1.37

NOTE: 1.

Fatigue Criteria (Loading Condition 2) is considered.

2.

Based on Pendent Operated Crane.

3.

Section Details: ( # = With No-Bearing Stiffener. ## = With Bearing Stiffener. ### = No Stiffener) Data Sequence: Cap Channel Top Flange Size (mm) Web Size (mm) Bottom Flange Size (mm) Weight (kN/m)

DM 03.10.00

8-10

ZAMIL STEEL BUILDINGS DESIGN MANUAL 8. Cranes systems design

PEB DIVISION

Table 8.2. – Top Running Crane Reactions at Runway Beam supports (Kn) MORRIS Crane Type

Crane Capacity (t)

1

2

3.2

Single Girder Cranes

5

6.3

8

10

12.5

16

Double Girder Cranes

20

25

DM 03.10.00

Crane Reaction Type

Bridge Span =15 m 6 7.5 9

Crane Beam Span (m) Bridge Span =18 m 6 7.5 9

Bridge Span =20 m 6 7.5 9

MAXIMUM

20

22

24

21

23

25

22

24

26

MINIMUM

11

12

13

12

14

15

13

14

16

LATERAL

1

1

1

1

1

1

1

1

1

LONGITUDINAL

2

2

2

2

2

2

3

3

3

MAXIMUM

29

31

33

30

33

35

31

34

36

MINIMUM

12

14

15

14

16

17

15

17

18

LATERAL

2

2

2

2

2

2

2

2

2

LONGITUDINAL

3

3

3

4

4

4

4

4

4

MAXIMUM

39

42

45

40

43

46

41

45

48

MINIMUM

14

15

17

15

17

19

16

18

20

LATERAL

3

3

3

3

3

3

3

3

3

LONGITUDINAL

5

5

5

5

5

5

5

5

5

MAXIMUM

55

59

63

57

62

66

58

63

67

MINIMUM

16

18

20

19

21

23

20

22

24

LATERAL

4

5

5

4

4

5

4

4

5

LONGITUDINAL

7

7

7

7

7

7

7

7

7

MAXIMUM

67

72

76

69

75

79

71

77

81

MINIMUM

19

22

24

21

24

26

23

25

28

LATERAL

5

6

6

5

5

6

5

5

6

LONGITUDINAL

8

8

8

9

9

9

9

9

9

MAXIMUM

83

88

94

84

91

98

86

93

100

MINIMUM

22

24

28

24

27

31

25

28

33

LATERAL

7

7

8

7

7

7

7

7

7

LONGITUDINAL

10

10

10

11

11

11

11

11

11

MAXIMUM

99

107

111

99

108

114

101

111

117

MINIMUM

24

28

31

26

31

33

27

32

35

LATERAL

9

9

9

8

9

9

8

9

9

LONGITUDINAL

12

12

12

13

13

13

13

13

13

MAXIMUM

119

128

134

120

130

137

123

134

141

MINIMUM

28

32

34

30

35

38

32

37

40

LATERAL

10

11

11

10

11

11

10

11

11

LONGITUDINAL

15

15

15

15

15

15

16

16

16

MAXIMUM

171

187

199

179

196

207

185

202

215

MINIMUM

15

18

21

21

24

27

26

29

33

LATERAL

13

14

15

13

14

15

13

14

15

LONGITUDINAL

23

23

23

25

25

25

25

25

25

MAXIMUM

204

222

236

214

233

247

222

242

257

MINIMUM

17

20

24

24

28

32

31

35

39

LATERAL

16

17

18

16

17

18

16

17

18

LONGITUDINAL

28

28

28

29

29

29

31

31

31

MAXIMUM

243

265

281

256

279

295

246

273

291

MINIMUM

18

21

25

27

31

35

34

39

44

LATERAL

19

21

22

19

21

22

18

20

21

LONGITUDINAL

33

33

33

35

35

35

36

36

36

8-11

ZAMIL STEEL BUILDINGS DESIGN MANUAL 8. Cranes systems design

PEB DIVISION

8.2.2. Under hung Cranes / Monorails Zamil Steel supply does not include the crane beam for under-hung cranes or monorails. Scope of supply includes only crane brackets with crane bracing and stops. Brackets for under hung cranes shall be designed to resist the vertical crane load in tension. The bracket web shall lie in the same plane as the rafter web. Unless otherwise required by design, the following bracket section shall be used for all under hung cranes: Overall depth = 200 mm Flanges = 150 mm x 6 mm Web = 5 mm The maximum capacity of this bracket is 236 kN (in tension). The cap plates on the bracket and the rafter flange to which the bracket is bolted to shall have a minimum thickness equal to that required for a pinned base plate under uplift which is 12mm. If the rafter flange thickness is less than required, then a scab plate, whose minimum thickness shall be equal to the required flange thickness less the actual flange thickness but not less than 6mm, shall be welded to the rafter flange. The weld size is determined based on the plate thickness joined. The rafter shall have a bearing stiffener welded to its bottom flange and web, and located beneath the centerline of the runway beam. This bearing stiffener shall extend over a length equal to the rafter web depth less 10mm. The welds (to the flange and web) on the stiffener shall be designed to resist the crane vertical load.

STIFFENER (NEAR SIDE AND FAR SIDE)

RIGID FRAME RAFTER

BRACE ANGLE CRANE BRACKET TEE CLIP

CRANE BEAM (NOT BY ZAMIL STEEL)

CAP CHANNEL

ELVEVATION UNDER SIDE OF BEAM

If the bracket is less than 300mm in length, then no brace angle is required and it is designed for an additional major-axis bending moment equal to the lateral load times the bracket length. Note that for all types of brackets supporting under-hung cranes, the frame shall be designed to resist a lateral load as well as a concentrated moment (if applicable) induced in brackets.

DM 03.10.00

8-12

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

8. Cranes systems design

8.2.3. Jib Cranes: Jib cranes are normally connected to one of the flanges of a column and are comprised of a boom, which turn in a circular motion carrying the lifted weight. The column flange shall be designed for a moment to be resisted by one end of the column in the weak direction, that is one flange (plate) which bends about its own major axis. An alternate to this is to design a hot-rolled channel to be attached to the rigid frame column to take the entire minor axis bending (on its own major axis).

DM 03.10.00

8-13

ZAMIL STEEL BUILDINGS DESIGN MANUAL 8. Cranes systems design

PEB DIVISION

The analysis and design shall be performed as follows:

H = PL/h2 RL = RR = Hh2/h

The design moment, M = RL h1 or M = RR h3 whichever is larger. For design according to AISC 89 Fb = 0.75 Fy .......... .(b f / 2t f ) < 54 Fy Otherwise

Fb = [1.075 − 0.006 (b f / 2t f ) Fy ]Fy ≤ 0 .6 Fy

Also fb = M/S where S = Sx of flange plate (≈ 0.5Sy of column section or Sx of the channel section) Note: Column stiffeners at attachment points of jib must be full depths of column otherwise torsional forces are transferred to the web.

DM 03.10.00

8-14

ZAMIL STEEL BUILDINGS DESIGN MANUAL 8. Cranes systems design

PEB DIVISION

8.2.4 Gantry Cranes & Semi-gantry Gantry cranes are cranes, which are comprised of a rigid frame supporting the hoist mechanism instead of the more common simple span bridge. The following are some of the typical representations of such cranes:

The analysis of the support runway beams for semi-gantry cranes is identical to the top-running runway beams with the exception of the lateral load. Lateral load is applied on one side of the crane only, equal to: 2 x 10% (C + T) or 0.2 (C + T)/n Where n = no. of wheels per side (normally 2) C = Crane capacity T = Trolley weight

DM 03.10.00

8-15

ZAMIL STEEL BUILDINGS DESIGN MANUAL 9. Mezzanine floor design

PEB DIVISION

CHAPTER 9: MEZZANINE FLOOR DESIGN Generally, the mezzanine framing is connected to the main rigid frame columns for lateral stability. Mezzanine beams and joists are analyzed and designed as simple span members. Zamil Steel’s standard mezzanine structure consists of built-up beams that support built-up, hot rolled or cold-formed mezzanine joists, which in turn support a metal deck. A reinforced concrete slab (not supplied by Zamil Steel) is cast on the metal deck as a finished surface. The metal deck is not designed to carry the floor live loads; it is intended only to carry the reinforced concrete slab during pouring. The reinforced concrete slab must be designed to carry the floor loads. Interior mezzanine stub columns that are 150x150x4.5mm and 200x200x6mm tube sections support mezzanine beams. The models adopted for the mezzanine framing are shown below:

However, when a building has more than two stories, horizontal sway may be a critical factor in the design of the structure. In those cases, the following models may be used for the analysis and design of such structures:

The above two models will generally yield the following results: decreased horizontal sway decreased size of mezzanine beam section decreased size of column section to which mezzanine beams are rigidly connected As a standard practice, Zamil Steel uses a metal deck system to support the mezzanine concrete floor slab when it is in green stage. Some mezzanines use checkered plate or grating flooring supported by hot rolled or built up ‘I' sections which are in turn supported by the mezzanine beams. Generally the built-up sections are used whenever the use of the heaviest cold-formed sections yields in an overstress and/or an overdeflection.

DM 03.10.00

9-1

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

9. Mezzanine floor design

It is essential for the Design Engineer to have an established clearance above and under the mezzanine beam, which is acceptable to the customer prior to the beginning of the design. This is important since changing this clearance, once design is started, may alter the overall design of the structure. 9.1. Design of Joists Joists are generally double "C" sections cold-formed of depth 200 mm or 300mm. The 200 C-section is available with thickness 2.0 and 2.5mm. The 300 C-section has only one thickness of 2.0mm. Refer tables 5.25 – 5.28 and clause 5.2.1.7 for the section properties and capacities. Joists are analyzed and designed as simply supported members spanning the distance between mezzanine beams. They are fastened to the floor panels at their top flange at 300mm intervals thus ensuring full allowable bending capacity. If a single ‘C' section is used, it is important to supply sag angles (or equivalent) to fasten continuously to the bottom flange of each joist, thus preventing possible side bowing of the joists when these are loaded. Use of such section is therefore not recommended. Double C back-to-back sections are used standard stitch bolted @ 1200 mm spacing. The design tables 9.1 , 9.2 and 9.3 for joists gives the allowable load in kN/m’. The design according to AISC(ASD) 1989 is based on deflection, bending stress and shear stress criteria. Example: Assume total dead load including the weight of panel, concrete slab, finish floor and self-weight of joist is approximately equal to 2.8kN/m2. The live load is 3kN/m2. Joist spacing of 1.5m and span =6m The total load on the joist is = (2.8 +3.0) x1.5 = 8.7kN/m 1. Cold-formed section From table 9.1 the section is][300x85x2.5 (weight = 19.42kg/m) 2. Hot rolled section From table 9.2 the section is UB 305x102x28 (weight = 28kg/m) 3. Built-up section From table 9.3 the section is W200x4 F175x8 (weight = 28.26kg/m)

DM 03.10.00

9-2

ZAMIL STEEL BUILDINGS DESIGN MANUAL 9. Mezzanine floor design

PEB DIVISION

Table 9.1. – Design Of Cold Formed Mezzanine Joists ALLOWABLE UNIFORM DISTRBUTED LOAD (KN/m') ALONG SIMPLLY SUPPORTED MEZZANINE JOIST Unsupported Length =0 Yeild Stress =34.5KN/Cm2 Cold Formed Sections ][200x85x2.0

Weight (Kg/m) 12.22

3 15.2 s

3.5 11.2 s

4 8.5 m

4.5 6.7 m

5 4.9 m

Joist Span (m) 5.5 6 6.5 3.7 m 2.9 m 2.2 d

7 1.8 d

7.5 1.5 d

8 1.2 d

8.5 1.0 d

9 0.8 d

][200x85x2.5

15.28

19.3 s

14.1 s

10.8 s

8.4 m

6.1 m

4.6 m

3.6 m

2.8 d

2.2 d

1.8 d

1.5 d

1.3 d

1.1 d

][300x85x2.0

15.6

21.3 s

18.2 s

15.2 s

12.0 s

9.7 s

8.0

6.8

5.8

5.0

4.1

3.4

2.8

d

2.4 d

][300x85x2.5*

19.42

36.3 s

26.7 s

20.4 s

16.1 s

13.1 s

10.8 s

][300x85x3.0*

23.32

45.4 s

33.3 s

25.5 s

20.2 m

16.3 m

13.5

][300x100x3.0*

25.2

52.3 s

38.4 s

29.4 s

23.2 s

18.8 m

15.6 m

13.1 m

10.3 m

8.2 m

6.7 m

][300x100x4.0*

33.6

70.6 s

51.9 s

39.7 s

31.4 s

25.4 s

21.0 s

17.1 s

13.4 m

10.8 m

8.7 m

][400x125x3.0*

33.2

53.3

45.7

40.0

35.6

31.5

26.1

21.9

18.7

16.1

][400x125x4.0*

44.28

123.3 s

s

s

90.6 s

s

69.4 s

s

54.8 s

s

44.4 m

s

m

s

36.7 m

s

9.1 s 11.3

m

s

30.8 m

m

d

d

d

7.5 s

6.0 s

4.9 d

4.0 d

3.4 d

2.8 d

8.9

7.2

5.8

4.8

4.0

d

3.4 d

5.5 d

4.6 d

3.9 d

7.2 m

6.0 m

5.1 d

m

s

26.3 m

m

m

22.6 m

14.0

m

m

19.7 m

12.3

d

m

16.8 m

m

10.7

9.0 m

14.0 m

11.8 m

Table 9.2. – Design Of Hot Rolled Mezzanine Joists ALLOWABLE UNIFORM DISTRBUTED LOAD (KN/m') ALONG SIMPLLY SUPPORTED MEZZANINE JOIST Unsupported Length =0 Yeild Stress =34.5KN/Cm2 Hot Rolled

Weight

Sections

(Kg/m)

IPE 200 A

18.4

Joist Span (m) 3

3.5

30.7

m m

UB 305x102x28

28

69.4

UB 400x140x39

39

123.3 m

4

22.5

m

51.0

m

90.6 m

4.5

15.9

m

39.1

m

69.4 m

5

11.2

d

30.9

m

54.8 m

5.5

8.1

d

25.0

m

44.4 m

6

6.1

d

20.7

m

36.7 m

6.5

4.7

d

16.0

m

30.8 m

7

3.7

d

12.6

m

26.3 m

7.5

3.0

d

10.1

m

22.6 m

8

2.4

d

8.2

m

18.8 m

8.5

2.0

d

6.8

d

15.5 d

9

1.7

d

1.4 d

5.6

d

4.8 d

12.9 d

10.9 d

Table 9.3. – Design Of Built-Up Mezzanine Joists ALLOWABLE UNIFORM DISTRBUTED LOAD (KN/m') ALONG SIMPLLY SUPPORTED MEZZANINE BEAM 2 Unsupported Length = 0 cm Yeild Stress = 34.5 KN/Cm Built Up

Weight

Sections

(Kg/m')

Joist Span (m) 3.00 m

3.50 m

4.00 m

4.50 d

5.00 d

5.50 d

6.00 d

6.50 d

7.00 d

7.50 d

8.00 d

8.50

9.00

d

1.4 d

W200x4 F125x5

16.09

27.7

W200x4 F125x6

18.06

32.3 m

23.7 m

18.1 m

13.1 d

9.5 d

7.1 d

5.5 d

4.3 d

3.5 d

2.8 d

2.3 d

1.9 d

1.6 d

W200x4 F150x6

20.41

37.8 m

27.8 m

21.3 m

15.3 d

11.1 d

8.4 d

6.4 d

5.1 d

4.1 d

3.3 d

2.7 d

2.3 d

1.9 d

W200x4 F150x8

25.12

48.8

m

m

m

d

d

d

d

d

d

d

d

d

2.5 d

W200x4 F175x8

28.26

56.2 m

41.3 m

31.6 m

23.2 d

16.9 d

12.7 d

9.8 d

7.7 d

6.2 d

5.0 d

4.1 d

3.4 d

2.9 d

W300x4 F125x5

19.23

45.2 m

33.2 m

25.4 m

20.1 m

16.3 m

13.4 m

11.3 d

8.9 d

7.1 d

5.8 d

4.8 d

4.0 d

3.3 d

W300x4 F125x6

21.20

52.0

m

m

m

m

m

m

m

d

d

d

d

d

3.9 d

W350x4 F125x6

22.77

62.8 m

46.2 m

35.4 m

27.9 m

22.6 m

18.7 m

15.7 m

13.4 m

11.5 d

9.4 d

7.7 d

6.4 d

5.4 d

W350x4 F150x6

25.12

69.9 s

53.3 m

40.8 m

32.2 m

26.1 m

21.6 m

18.1 m

15.4 m

13.3 d

10.8 d

8.9 d

7.4 d

6.3 d

W400x4 F150x6

26.69

61.2

s

m

m

m

m

m

m

m

d

d

8.4 d

W400x4 F175x6

29.05

61.2 s

52.5 s

45.9 s

40.8 s

34.7 m

28.7 m

24.1 m

20.5 m

17.7 m

15.4 m

13.5 d

11.2 d

9.5 d

W450x4 F175x6

30.62

54.4 s

46.6 s

40.8 s

36.3 s

32.6 s

29.7 s

27.2 s

23.7 m

20.4 m

17.8 m

15.6 m

13.8 m

12.3 d

W450x4 F150x8

32.97

54.4

s

s

s

s

s

s

s

m

m

m

m

13.7 m

W500x5 F150x8

38.47

95.6 s

82.0 s

71.7 s

63.7 s

53.1 m

43.9 m

36.9 m

31.4 m

27.1 m

23.6 m

20.8 m

18.4 m

16.4 m

W500x5 F175x8

41.61

95.6 s

82.0 s

71.7 s

63.7 s

57.4 s

49.4 m

41.5 m

35.4 m

30.5 m

26.6 m

23.3 m

20.7 m

18.4 m

20.3

35.8

38.2

52.5

46.6

s

15.6

27.4

29.3

45.9

40.8

s

11.1

20.1

23.1

37.9

36.3

8.1

14.7

18.7

30.7

32.6

6.1

11.0

15.5

25.4

29.7

4.7

8.5

13.0

21.3

27.2

NOTES :1. Allowable deflection span/240 . 2. Clips = L65x65x5(A36) 4. Joists are considered fully braced. 5. Unstiffened webs (Kv = 5.34) 6. (*) Not in stock sections 7. (m) bending moment control (CB =1) 8. (d) deflection control 9. (s) Shear at support control (for end connection types with no web holes)

DM 03.10.00

3.7

6.7

10.3

18.2

25.1

s

2.9

5.3

8.2

15.7

22.7

2.4

4.3

6.7

13.7

19.7

2.0

3.6

5.5

11.9

17.4

1.6

3.0

4.6

10.0

15.4

3. Steel yield strength, Fy = 34.50 kN/cm2.

9-3

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

9. Mezzanine floor design

9.2. Design of Joists Connections Joists ends are generally bolted to the mezzanine beam webs using 12-mm diameter A307N bolts, and A36 angles. Double `C' and built-up joists use two angles, one on either side of the joists webs. Refer to table 9.4 for end capacities. Connections MZE-021 through MZE-024 are employed for connecting the joists with mezzanine beam web. If joists have to be connected to built up column web or flange the same connections are used. Connections MZE-025, MZE-026 and MZE-027 are used when joists have to be connected to tube columns. MZE-018 and MZE-019 are used for seated connections. MZE-021 •

Shear Diameter of bolt = 12mm For A 307 Bolts: Fv = 6.895kN/cm2 (10ksi) Single shear for one bolt = Fv x Ab = 6.895 x π x(0.6)2 = 7.8kN 4 bolts in single shear or 2 bolts in double shear = 4 x 7.8 = 31.2kN ---Governs



Check for bearing Fp = 1.2 Fu = 1.2 x44.8 = 53.76 kN/cm2 Allowable load per one bolt = 0.3x1.2x53.76 = 19.35kN For 2 bolts ⇒ 2 x 19.35 = 38.71kN



Check for edge distance Check for minimum edge distance Le > 1.5d = 1.5x12 = 18mm > 35mm OK Check for minimum spacing s > 3d ⇒ 50mm > 3x12 = 36mm OK

DM 03.10.00

9-4

ZAMIL STEEL BUILDINGS DESIGN MANUAL 9. Mezzanine floor design

PEB DIVISION

Table 9.4. – Mezzanine Joist Connections All Bots: A 307 M12 x 38 2 2 Joist/Beam: Fy = 34.5kN/cm ; Fu = 44.8kN/cm 2; 2 Angles: A572 Grade 50 ∠75x75x6 (UNO); Fy = 34.5kN/cm Fu = 4.8 kN/cm Connection Type MZE-021

End Connections Capacity(kN) 31.2

Connection Type MZE-022

End Connection Capacity(kN) 46.8

Connection Type MZE-023

Connection Type

End Connection Capacity(kN)

Connection Type

MZE-017

31.2

MZE-024

Connection Type For Hot Rolled Joist

End Connection Capacity(kN)

Connection Type For B/U Joist

MZE-018

65

MZE-019

End Connection Capacity(kN) 62.4

End Connection Capacity(kN) 31.2

End Connection Capacity(kN) 55 for 3mm 73 for 4mm Web Web

Note: Weld Size X= Joist Web Thickness ( X < 4mm )

DM 03.10.00

9-5

ZAMIL STEEL BUILDINGS DESIGN MANUAL 9. Mezzanine floor design

PEB DIVISION

Table 9.4.continued – Mezzanine Joist Connections All Bolts: A 307-M12mm x 38 2 2 Joist: Fy = 34.5kN/cm ; Fu = 44.8kN/cm ; Min. Web Thickness = 4mm 2 2 End Plate: 10mm thick; Fy = 34.5kN/cm ; Fu = 44.8kN/cm Weld Size: X = 5mm for 150 Tube Column; 6mm for 200 Tube Column

Connection Type MZE-025

Connection Type MZE-027

DM 03.10.00

End Connection Capacity(kN) 15.6

Connection Type

End Connection Capacity(kN)

MZE-026

23.4

End Connection Capacity(kN) 31.2

9-6

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

9. Mezzanine floor design

9.3. Design of Beams Mezzanine beam sections are usually built up, the top flanges are assumed to be braced against lateral buckling at each joist location. The beam deflection shall be limited to span/240 under dead and live loads and span/360 under live load alone (refer to clause 2.3). If the beam end connection is a one sided connection, the minimum angle thickness shall be 10 mm, but it has to be checked for torsion also. Refer to table 9.5. for quick selection of beams built-up sections with joist spacing 2.00m . Note: If mezzanine beam is supporting a block-wall/partition wall its load (kN/m’) should be added to floor load. Example: Assume total dead load including the weight of panel, concrete slab, finish floor, weight of joists and selfweight of beam is approximately equal to 3.0kN/m2. The live load is 3kN/m2. Joist span =6m, Beam span = 8m The total load on the interior beam is = (3.0 +3.0) x6 = 36kN/m From table 9.5 the section is W500x5 F200x12 (weight = 57.31kg/m)

DM 03.10.00

9-7

ZAMIL STEEL BUILDINGS DESIGN MANUAL 9. Mezzanine floor design

PEB DIVISION

Table 9.5. – Design Of Built-Up Mezzanine beams ALLOWABLE UNIFORM DISTRBUTED LOAD (KN/m') ALONG SIMPLLY SUPPORTED MEZZANINE BEAM 2 Unsupported Length = 200 cm Yeild Stress = 34.5 KN/Cm Built Up

Weight

Sections

(Kg/m')

Beam Span (m) 4.00 m

4.50 m

5.00 m

5.50 m

6.00 m

6.50 m

7.00

7.50

8.00

8.50

9.00

9.50

10.00

d

d

d

d

d

d

2d

W300x4 F125x5

19.23

23

W300x4 F125x6

21.20

26 m

21 m

17 m

14 m

12 m

10 m

8d

7d

6d

5d

4d

3d

3d

W300x4 F150x6

23.55

33

m

m

m

m

m

d

d

d

d

d

d

d

3d

W300x4 F150x8

28.26

42 m

33 m

27 m

22 m

19 m

15 d

12 d

10 d

8d

7d

6d

5d

4d

W300x4 F175x8

31.40

49 m

39 m

32 m

26 m

22 m

18 d

14 d

11 d

9d

8d

7d

6d

5d

W400x4 F125x5

22.37

32 m

25 m

20 m

17 m

14 m

12 m

10 m

9m

8m

7m

6m

5d

5d

W400x4 F125x6

24.34

37

m

m

m

m

m

m

m

m

m

m

m

d

5d

W400x4 F150x6

26.69

46 s

36 m

30 m

24 m

20 m

17 m

15 m

13 m

12 m

10 d

8d

7d

6d

W400x4 F150x8

31.40

46 s

41 s

37 s

31 m

26 m

22 m

19 m

17 m

15 m

13 d

11 d

9d

8d

W400x4 F175x8

34.54

46 s

41 s

37 s

33 s

30 m

26 m

22 m

20 m

17 m

14 d

12 d

10 d

9d

W400x4 F175x10

40.04

46

s

s

s

s

m

m

d

d

d

11 d

W400x5 F175x10

43.18

86 m

68 m

55 m

45 m

38 m

32 m

28 m

24 m

21 m

18 d

15 d

13 d

11 d

W500x5 F150x6

33.76

--

--

41 m

34 m

28 m

24 m

21 m

18 m

16 m

14 m

13 m

11 m

10 m

W500x5 F150x8

38.47

--

--

51 m

42 m

35 m

30 m

26 m

23 m

20 m

18 m

16 m

14 m

13 m

m

m

m

m

m

m

m

m

m

15 d

18

26

29

41

14

21

24

37

s

12

17

20

33

15

16

31

12

14

28

10

12

26

8

11

24

6

9

21

5

8

18

4

7

15

18

3

4

6

13

47.10

--

--

57 s

52 s

48 s

42 m

36 m

32 m

28 m

25 m

22 m

20 m

18 m

W500x5 F200x10

51.03

--

--

57 s

52 s

48 s

44 s

41 m

35 m

31 m

28 m

25 m

22 m

20 m

W500x5 F200x12

57.31

--

--

57 s

52 s

48 s

44 s

41 s

38 s

36 s

32 m

29 m

26 m

23 m

m

m

m

24 m

m

21

3

W500x5 F175x10

m

23

4

57

m

27

5

--

m

30

s

6

--

m

35

s

7

41.61

m

41

s

9

W500x5 F175x8

m

49

10

17

W500x6 F200x12

61.23

--

--

95

W600x6 F200x10

59.66

--

--

--

--

69 s

61 m

52 m

46 m

40 m

35 m

32 m

28 m

26 m

W600x6 F200x12

65.94

--

--

--

--

69 s

64 s

59 s

53 m

46 m

41 m

37 m

33 m

30 m

W600x6 F225x10

63.59

--

--

--

--

69 s

64 s

57 m

50 m

44 m

39 m

35 m

31 m

28 m

s

s

m

m

m

m

33 m

79

66

56

49

s

42

s

37

33

29

26

W600x6 F225x12

70.65

--

--

--

--

69

W600x6 F225x10

63.59

--

--

--

--

69 s

64 s

57 m

50 m

44 m

39 m

35 m

31 m

28 m

W600x6 F225x12

70.65

--

--

--

--

69 s

64 s

59 s

55 s

51 m

45 m

40 m

36 m

33 m

W600x6 F250x12

75.36

--

--

--

--

69 s

64 s

59 s

55 s

52 s

49 s

44 m

39 m

36 m

s

s

s

s

s

s

W600x6 F250x14

83.21

--

--

--

--

69

W600x8 F250x14

92.63

--

--

--

--

W700x8 F250x12

91.06

--

--

--

--

--

W700x8 F250x14

98.91

--

--

--

--

--

64

64

118 m 100 m

59

59

55

55

51

52

45

49

40

46

s

36

43

s

40 m

87 m

75 m

66 m

59 m

52 m

47 m

42 m

--

92 m

80 m

71 m

63 m

56 m

50 m

45 m

--

104 m

91 m

80 m

71 m

63 m

57 m

51 m

m

m

m

m

m

m

52 m

W700x8 F300x12

100.48

--

--

--

--

--

--

107

W700x8 F300x15

114.61

--

--

--

--

--

--

120 s

111 m

98 m

87 m

77 m

69 m

63 m

W800x8 F300x12

106.76

--

--

--

--

--

--

--

--

92 s

85 m

76 m

68 m

61 m

W800x8 F300x15

120.89

--

--

--

--

--

--

--

--

92 s

86 s

82 s

77 s

73 m

W800x8 F350x15

132.67

--

--

--

--

--

--

--

--

92 s

86 s

82 s

77 s

73 s

93

82

72

64

58

NOTES :1. Allowable deflection span/240 . 2. Choose the adequate connections from tables 9.6-9.9 E=19995 kN/cm2 3. Steel yield strength, Fy = 34.50 kN/cm2 4. Unstiffened webs (Kv = 5.34) 5. (*) Not in stock sections 6. (m) bending moment control (CB =1) 7. (d) deflection control 8. (s) Shear at support control (for end connection types with no web holes)

DM 03.10.00

9-8

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

9. Mezzanine floor design

9.4. Design of Beam Connections Mezzanine connections MZE-001, MZE-003, MZE-005 and MZE-007 are used to connect mezzanine beams to built-up column webs by means of angle T-clip bolted connections. Connections MZE-002, MZE-004, MZE-006 and MZE-008 are used to connect mezzanine beams to builtup column flanges. A plate is welded at the end of the beam, which is bolt connected to the column flange. Connections MZE-009, MZE-011, MZE-013 and MZE-015 are used to connect mezzanine beams to tube columns. In this type of connections tube is welded to plate which is then connected to another outstanding plate forming a T-shape. The outstanding plate is bolt connected to the web of the beam. Connections MZE-010, MZE-012, MZE-014 and MZE-016 are used to connect hot-rolled mezzanine beams to tube columns. These are similar to MZE-009 except that the outstanding plate is bolted to a plate, which is welded to the beam. Since hot-rolled beams are not commonly used, this type of connection is normally not used. Furthermore the capacity is significantly reduced due to eccentric weld at the beam end. MZE-001 A325 Bolts Dia 20mm; Fv= 14.48kN/cm2 (21ksi) •

Shear Single shear for one bolt = 14.48 x π x (1.0)2 = 45.5kN 4 bolts in single shear = 4 x 45.5 = 181.96kN



Bearing Fp = 1.2Fu = 1.2 x 44.8 = 53.76kN/cm2 Allowable load/bolt = 2.0 x 0.4 x 53.76 = 43.01kN Allowable load in bearing = 3 x 43.01 = 129kN ---Governs

DM 03.10.00

9-9

ZAMIL STEEL BUILDINGS DESIGN MANUAL 9. Mezzanine floor design

PEB DIVISION

Table 9.6. – Mezzanine Beam Connections All Bots: A 325 N 2 2 Beams: Fy = 34.5kN/cm ; Fu = 44.8 kN/cm 2 2 Angles: A572 Grade 50 ∠75x75x6 (UNO); Fy = 34.5 kN/cm , Fu = 44.8 kN/cm Bolt Type

Diameter (mm)

MZE-001

20

MZE-005

20

DM 03.10.00

End Connection Capacity, kN Beam Web Beam Web Thk : 5 mm. Thk. : 4 mm 129.0 161.3

215.0 for 4mm Web

268.8 for 5mm Web

Bolt Type

Diameter (mm)

MZE-003

20

MZE-007

20

End Connection Capacity, kN Beam Web Beam Web Thk : 5 mm. Thk. : 4 mm 172.0 215.0

322.6 for 5 mm web

387.1 for 6 mm web

455.1 for 8 mm web

9-10

ZAMIL STEEL BUILDINGS DESIGN MANUAL 9. Mezzanine floor design

PEB DIVISION

Table 9.7. – Mezzanine Beam Connections All Bots A 325 N 2 2 Beams: Fy = 34.KN/cm ; Fu = 44.8 KN/cm 2 2 End Plate: 10mm thick; Fy = 34.5 KN/cm ; Fu = 44.8 KN/cm Welding using E70XX Electrode; Weld Size = Beam Web thickness (but < 5mm) Bolt Type

Diameter (mm)

MZE-002

20

MZE-006

20

DM 03.10.00

End Connection Capacity, kN Beam Web Beam Web Thk Thk. : 4 : 5 mm. mm 114.3 141.5

202.6 for 4mm web

251.9 for 5mm web

Bolt Type

Diameter (mm)

MZE-004

20

MZE-008

20

End Connection Capacity, kN Beam Web Thk. : 4 Beam Web Thk : 5 mm. mm 158.4 196.7

307.1 for 5 mm web

366.8 for 6 mm web

455.1 for 8 mm web

9-11

ZAMIL STEEL BUILDINGS DESIGN MANUAL 9. Mezzanine floor design

PEB DIVISION

Table 9.8. – Mezzanine Beam Connections All Bots A 325 N 51 2 2 Beams: Fy = 34.5kN/cm ; Fu = 44.8kN/cm ; Min. Web Thickness = 4mm 2 2 End Plate: 10mm thick; Fy = 34.5kN/cm ; Fu = 44.8 kN/cm Weld Size:X = 5mm for 150 Tube Column; 6mm for 200 Tube Column Type MZE-009

Bolt Diameter 20mm

End Connection Capacity, KN 136.5

MZE-011

Bolt Diameter 20mm

MZE-015

20mm

Type

End Connection Capacity, KN 182.0

For beam web thickness of 4mm Capacity is 129kN MZE-013

DM 03.10.00

20mm

227.5

273.1

9-12

ZAMIL STEEL BUILDINGS DESIGN MANUAL 9. Mezzanine floor design

PEB DIVISION

Table 9.9. – Mezzanine Beam Connections All Bots A 325 N 2 2 Beams: Fy = 34.5kN/cm ; Fu = 44.8 kN/cm 2 2 End Plates: Fy = 34.5 kN/cm ; Fu = 44.8 kN/cm Welding using E70XX Electrode Weld Size:X = 5mm for 150 Tube Column ; 6mm for 200 Tube Column Y = 5mm / Beam Web Thickness (whichever is lesser) Type MZE-010

Bolt Dia. 20mm

MZE-014

20mm

DM 03.10.00

End Connection Capacity, kN 79.7 for 4mm 99.6 for 5mm Web Web

162.2 for 5mm Web

194.6 for 6mm Web

Type MZE-012

Bolt Dia. 20mm

MZE-016

20mm

End Connection Capacity, kN 99.6 for 4mm 124.5 for 5mm Web Web

201.6 for 5mm Web

242.0 for 6mm Web

9-13

ZAMIL STEEL BUILDINGS DESIGN MANUAL 9. Mezzanine floor design

PEB DIVISION

9.5. Design of Columns Mezzanine stub columns may be either hot rolled tube columns, hot rolled or built-up "H" sections. Columns which are pinned at base and top are designed for an axial load as well as a differential bending moment (if any) applied at the intersection of the mezzanine beams and the column. This bending moment is normally due to unequal spans on the sides of an "H" column, or to a similar condition. For quick selection of mezzanine columns use the following chart.

Table 9.10. – Tube Column Properties & Allowable load Tube

Size B x D x T (mm)

Weight kg/m

Area cm2

Ix cm4

Sx cm3

rx cm

MT2 MT4

150x150x4.5 200x200x6.0

20.1 35.8

25.67 45.63

896 2830

120 283

5.91 7.88

Fy = 32.5 kN/cm2; Es = 20,000 kN/cm2; End Conditions as Pinned

Allowable Loads For Mezzanine Columns 800

Allowable Axial Load (kN)

700 600 M

500

MT4

400 300

MT2 M

200 100 0 2

3

4

5

6

7

8

9

10

11

12

Unbraced Length (m) KL KL > 200 for > MT2 200 r

r

DM 03.10.00

9-14

ZAMIL STEEL BUILDINGS DESIGN MANUAL 9. Mezzanine floor design

PEB DIVISION

For the design the column base plate and cap plate the table 9.11. can be used. Table 9.11. – Column Base & Cap Plates Design

Tube Code MT2 MT4

Allowable Loads on Base Plate in Bearing Condition (kN) Base Plate Tube Size 10 12 15 Thickness (mm) 150 x 150 59.3 85.3 133.3 200 x 200 83.2 119.9 187.4

20

25

237.0 333.0

370.3 520.4

Note: Base plate size is 230 mm x 340 mm for both tube columns MT2 and MT4 when anchor bolt φ is < 30mm. For φ is > 30mm the base plate size is 250mm x 420mm

DM 03.10.00

9-15

ZAMIL STEEL BUILDINGS DESIGN MANUAL 9. Mezzanine floor design

PEB DIVISION

9.6. Design of Flooring 9.6.1 Mezzanine Deck Total design load shall be equal to the total dead weights of the concrete slab and panel. This is so because the panel is assumed to support the wet concrete until the latter hardens and the concrete slab (excluding the panel) will then support the floor live load. The standard floor panels are 0.5-mm type A (high-rib) or type G(deep-rib) or type K. A live load of 0.5kN/m2 has to be considered to account for the wet concrete workmanship. Refer to table 5.1, 5.3 and 5.6 for design of mezzanine deck. 9.6.2. Chequered Plate Allowable loads for 5mm thick chequered plate are calculated for three cases: Single Span Two Continuous Spans Three Continuous Spans The maximum allowable deflection considered is Span/180.

A llo w ab le L o a d s fo r C h e q u ere d P la te 30 28 26 24

Allowable Load (kN/m2)

22 20 18 O ne Span

16

T w o S p an s

14

T h ree S p an s

12 10 8 6 4 2 0 0 .4

0.5

0 .6

0 .7

0.8

0.9

1

1.1

1.2

1 .3

1.4

1.5

S p an (m )

DM 03.10.00

9-16

ZAMIL STEEL BUILDINGS DESIGN MANUAL 9. Mezzanine floor design

PEB DIVISION

9.6.3. Gratings Allowable loads are adopted from safe load tables of Flowforge (grating) panels of REDMAN FISHER for load bearing bars @ 30mm pitch and Bearer bar section of 30mm x 3mm.

Span (m)

0.3

0.5

0.6

0.8

0.9

1.1

1.2

1.4

1.5

1.7

1.8

Allowable Load (kN/m2)

224

100

56

36

25

16

11

8

5

4

3

A l l owabl e L oads for G r ati n g s

150

140

130

120

110

100

Load (kN/m2)

90

80

70

60

50

40

30

20

10

0 0 .2

0 .4

0 .6

0 .8

1 .0

1 .2

1 .4

1 .6

1 .8

S i m p l y su p p o r te d sp a n (m )

DM 03.10.00

9-17

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

9. Mezzanine floor design

9.7.Miscellaneous Items 9.7.1. Staircases Zamil Steel standard staircase is designed to provide a firm and rigid construction. The stair stringers are detailed in such a way that different stair treads (such as checkered plate, grating or concrete filled treads) can be accommodated without modifications. Zamil Steel standard staircase is a double flight type with intermediate landing. The main structural members are shop assembled to ease erection leaving only the simple task of connecting the main members to the floor framing and attaching the selected type of treads along with Zamil Steel's standard handrail system. Zamil Steel Standard Staircase is designed for the following: 1)

Staircase can span upto 8500 mm considering the stringer (PFC 260 x 75 x 28) capacity. Span is the horizontal distance between the two supports regardless of slope.

2)

Treads can be 30 x 3 x 30 x 100 Grating or 5mm thick "Z" shaped chequerred plate or 5 mm thick "C" shaped plain plate filled with concrete

3)

Stringer is designed for a 5.00 kN/m2 live load on staircase in addition to its self weight.

4)

Treads are designed for their own self weight plus a live load of 5.00 kN/m2 uniformly distributed load over full area or 1.5 kN concentrated load at tread midpoint.

5)

Maximum allowable deflection is span/240 for stringer and treads.

6)

Stringer is connected to floor slab by means of 2 expansion bolts.

7)

Tread run is 260 mm.

Note: For details of staircase with concrete, gratings and chequerred plate, refer Detailing Manual. 9.7.2. Handrails Zamil Steel standard Handrail is built out of 48 mm diameter pipe that is used as a top rail and a tube 40mm x 40mm for mid rail and for handrail posts. The height of the post is 900 mm. measured from the top of the flooring to the centerline of the top rail. Handrail posts are connected to the stringer by means of 6mm plates that are welded to the post at the bottom. Handrails are provided at platforms, catwalks and staircases for safety reasons.

DM 03.10.00

9-18

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

9. Mezzanine floor design

9.8. Special Cases 9.8.1. Roof Platforms A roof platform is a structural framing system mounted on top of the roof and is specifically designed to support heavy roof accessories, such as HVAC units, water tanks and other miscellaneous roof equipment. Zamil Steel standard roof platforms are made of built-up beam sections supported by built up column stubs, which are bolted to the top rafter top flanges. Bracing is sometimes provided in both directions to ensure the stability of the framing system. Normally gratings or chequered plates are used at roof platforms. Note that spacing of joists should be properly designed for chequered plates. Beams and if required joists should be designed to withstand the loading using simple shear connections similar to mezzanine beams and joists. The rafter supporting the roof platform shall be designed for the load applied at the stub columns locations. When a platform is required to support equipment it is recommended that the platform be enlarged to create a working area around the equipment for future maintenance of the equipment. Roof platforms differ from roof framed openings. Roof framed openings normally support lighter equipment that does not require frequent maintenance. When several platforms exist on top of the roof of a pre-engineered steel building then it is recommended that the platforms be provided with catwalks to avoid stepping on the high rib of the roof sheeting. The provision of handrails to roof platform is optional and should be specified at the time of requesting a quotation. 9.8.2. Catwalk A Catwalk is a narrow walkway used primarily by maintenance crews to provide access to mechanical equipment normally supported on roof platforms. Catwalks are usually: 1. mounted alongside crane beams. 2. suspended underneath rigid frame rafters. 3. elevated above the top of the building roof. The main frame column/rafter shall be designed to support the load applied at the point where catwalk is connected. Catwalks consists of beams, joists (normally cold-formed C sections) and gratings. Catwalks are generally provided with handrails for safety purposes. Handrails can be placed on one side or on both sides of the catwalk. Catwalk flooring can be made of steel grating or checkered plate. Catwalks should not be confused with roof platforms. Roof platforms support equipment and provide a working area around the equipment. Catwalks provide access to roof platforms, etc. Zamil Steel catwalks have two standard widths: 1000 mm and 1200 mm. Other sizes are also available depending on customer's requirements. In most buildings, access to the roof is limited to one or two external or internal locations. When the access to a roof is external, a catwalk is provided between the initial access point on the roof and the platforms on the roof. It is highly recommended to consider the provision of catwalks early in the design stage of pre-engineered steel buildings. When heavy equipment are supported on roof platforms access to those platforms should be properly laid out to avoid causing damage to the roof sheets.

DM 03.10.00

9-19

ZAMIL STEEL BUILDINGS DESIGN MANUAL 9. Mezzanine floor design

PEB DIVISION

9.9. Floor vibration In this study two types of vibrations have been considered for the design of steel-joist-concrete-slab flooring systems. The first one is due to heel drop impact applied by people walking on mezzanine floor which may cause perceptible vibrations depending upon the stiffness and inherent damping in the mezzanine system. The other type of vibration is due to an impact of suddenly applied force or an oscillating machine. Mainly stiffness of steel joists, their spacing and thickness of concrete slab are affected most by the localized impacts of dynamic loads due to smaller tributary areas as compared to mezzanine beams. Transformed sections have been used for the analysis with non-composite behavior. 9.9.1. Vibration due to heel drop impact Following are the design steps given for considering the vibration effect on the design of steel-joistconcrete-slab floor systems subjected to heel drop impact1. Step 1. Estimate Damping in the finished floor system. If the damping is more than 8-10% then vibration analysis is not required. The guidelines for estimating the damping are given as follows: a) Bare Mezzanine: 1% - 3% (1% for thin slab, 3% for thick slab) For 100mm thick slab use 1.5% Damping b) False Ceiling: 1% c) HVAC Ducting: 3% d) Partitions: 15% Step 2. Compute the transformed moment of inertia It for one beam. Transformed section is obtained by replacing the effective width of concrete slab by an equivalent steel plate of same thickness but having a reduced width of b/n, n being the modular ratio (n = Es / Ec = modulus of elasticity of steel / modulus of elasticity of concrete). n = 9 for normal-weight concrete and 14 for light-weight concrete. Effective depth of the concrete slab de corresponds to the solid slab equal in weight to the actual slab including concrete in the valleys of decking plus weight of steel panel.

d e

DM 03.10.00

9-20

ZAMIL STEEL BUILDINGS DESIGN MANUAL 9. Mezzanine floor design

PEB DIVISION

Step 3. Compute the natural frequency f of one joist considered as a simply supported transformed teebeam section as follows: For uniformly distributed load w :

f = 1.57

gEI t wL3

Where g E It w L f

= Acceleration due to gravity ( 980 cms/sec2) = Modulus of Elasticity of Steel (in kN/cm2) = Transformed moment of Inertia (in cm4) = Total load (in kN) = Joist span ( in cms) = natural frequency of one joist in cps (Hz)

b)

For the Mezzanine Joists supporting a single concentrated load W applied at mid-span:

f= c)

6.93 2π

EI t g WL3

Mezzanine Joists with both concentrated load W at mid-span and uniformly distributed load w:

f=

6.93 2π

EI t g 3

WL + 0.486wL4

Step 4. Compute Amplitude Aot of single joist as follows:

A 0t = DLFmax

L3 18EI t

Wherein DLFmax (Maximum dynamic load factor) can be obtained from the calculated frequency f in cps (Hz) in step 3 by using Fig. 1

DM 03.10.00

9-21

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

9. Mezzanine floor design

Step 5. Estimate Effective Number of Joists Neff using Fig. 2 Since the use of amplitude of a single tee-joist overestimates the amplitude of a floor system subject to the heel-drop impact the effective number of joists Neff resisting the impact needs to be calculated. In Fig.2 s is spacing of joist, de is effective depth of slab, L the joist span and I = It (transformed moment of inertia of one joist)

DM 03.10.00

9-22

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

9. Mezzanine floor design

Step 6. Compute Amplitude of the floor system, Ao = Aot / Neff Step 7. Plot on the Modified Reiher-Meister scale Fig. 3 and find out the degree of perceptibility of vibration using Ao in inches and frequency f in cps (Hz). In Fig.3 Vibrations are classified in four categories as follows: Not Perceptible --Vibration though present, is not perceived by the occupants Slightly Perceptible --Vibration is perceived but it does not annoy Distinctly Perceptible --Vibrations annoys and disturbs Strongly Perceptible --Vibration is so severe that it makes people sick Hospital and School buildings should not exceed the boundary of ‘Not Perceptible’. For Office and other buildings vibration should be limited to ‘Slightly Perceptible’ range.

DM 03.10.00

9-23

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

9. Mezzanine floor design

Step 8. Redesign the Mezzanine System if necessary in order to decrease the vibration perceptibility by: • • • •

increasing the joist section decreasing the joist spacing decreasing the span of joists increasing the slab thickness

Note that increased slab thickness, presence of partitions and ductwork increase the damping significantly and hence help minimize the floor vibrations.

DM 03.10.00

9-24

ZAMIL STEEL BUILDINGS DESIGN MANUAL 9. Mezzanine floor design

PEB DIVISION

Example Check the following floor system for susceptibility to vibration: Data: 100mm Concrete Slab (Normal-Weight Concrete, Density 24kN/m3, n = Es/Ec = 9) Use Type ‘G’ Deck (Weight = 0.0562kN/m2) Span of Joists = 6m Joist Spacing = 1.75m Joist Section 130x6Flanges + 300x3 Web ( As = 24.6cm2 , Ixx = 4,327cm4 ) Assume Hung Ceiling and Little DuctWork. Solution: 1)

2)

Estimate Damping: Slab + Joist 3.0% Hung Ceiling 1.0% Duct Work 1.0% Total 5.0% < 8%

Need to investigate floor system.

Transformed Section Properties: Calculate Effective depth de of an equivalent solid slab by equating: Weight of Ribbed Concrete Slab + Weight of Steel Panel = Weight of Solid Slab

Considering the ribbed depth of 5cm: [(20x5x24x10-6) – (4.5x5x24x10-6)] + (20x0.0562x10-4) = 20x d x 24x10-6 d = 4.11cms Effective Depth de = 4.11 + 5 = 9.11cms

DM 03.10.00

9-25

ZAMIL STEEL BUILDINGS DESIGN MANUAL 9. Mezzanine floor design

PEB DIVISION

Location of C.G. of Transformed Joist Section:

Yb = Yb = 34.08 cms

19.44 x 9.11x (31.2 + 0.89 + 9.11 / 2) + 24.6 x15.6 177.1 + 24.6

Moment of Inertia of Transformed section It:

It = It = 15,118 cm4

3)

19.44 x9.113 + 177.1x 2.565 2 + 4327 + 24.6 x18.48 2 12

Frequency f of Mezzanine Joist Transformed Section Weight of Mezzanine Joist W: W=

f = 1.57

24x1.75x6x9.11x10-2 + 0.18942x6 = 24.09 kN

gEI t WL3 f = 1.57

980x20000x15118 24.09x600 3

f = 11.85 cps 4)

Amplitude of single joist Aot : 0.05f From Fig.1

DM 03.10.00

0.05x11.85 = 0.59 DLFmax = 1.3

9-26

ZAMIL STEEL BUILDINGS DESIGN MANUAL 9. Mezzanine floor design

PEB DIVISION

A 0t = DLFmax A 0t = 1.3

L3 18EI t

600 3 18 x 20000 x 15118

Aot = 0.0516 cms Effective No. of joists Neff :

5)

s/de = 175/9.11 = 19.21

L4 600 4 = = 8.57 x10 6 I t 15118

Neff = 2.4

From Fig 2 6)

System Amplitude: or Ao = 0.0085 inch

A0 =

0.0516 = 0.0215 cms 2 .4

Using Modified Reiher-Meister Scale Fig 3, it results to be in the range of distinctly perceptible vibration. N.G. This is not acceptable and needs revision in design either by • • •

decreasing the joist spacing increasing the joist section increasing the slab thickness

DM 03.10.00

9-27

ZAMIL STEEL BUILDINGS DESIGN MANUAL 9. Mezzanine floor design

PEB DIVISION

9.9.2. Vibration due to forcing impact Whenever the mezzanine floor is subjected to dynamic loads such as suddenly applied load or an oscillating machine, all the components of mezzanine floor have to be designed for such loads. The simplest approach in such cases is to calculate the dynamic load factor and multiply it with static loads to get design loads. In this section dynamic load factors for some common cases are provided. i)

Damped Harmonic Excitations

The forcing function is defined as: F sin ωf t where F is the amplitude of the forcing function and ωf is the frequency of the forcing function. The Dynamic Load Factor (DLF) is given as follows:

[1 - ( DLF =

ωf 2 ω ) ] sin ω f t - (2 β f ) cos ω f t ω ω ωf 2 2 ω [1 − ( ) ] + [2 β f ]2 ω ω

ω = natural frequency of the structure (radians/sec) β = damping ratio = c / (2Mω) ; M = mass of joist/beam supporting the vibrating machine The max DLF is given as:

1

DLFmax = [1 - (

ωf 2 2 ω ) ] + [2 β f ]2 ω ω

F

t

0 -F

If damping is negligible then:

DLFmax =

1 ω 1 − ( f )2 ω

Note that when ω = ωf , DLFmax will be ∞ that means it will lead to a large amplitude (failure). This phenomenon is called ‘Resonance’. This situation can be avoided by making ω >> ωf ii) Suddenly Applied Constant Force Example of this kind of force is like an object falling on the floor from certain height. The DLF depends on the natural frequency of the resisting joist/beam. DLF = 1- cos ω t

F

DLFmax = 2 iii)

Triangular Impulsive Force

0

t

It is a case of suddenly applied load and then gradually unloaded within time td (seconds). DM 03.10.00

9-28

ZAMIL STEEL BUILDINGS DESIGN MANUAL 9. Mezzanine floor design

PEB DIVISION

For t < td

DLF = 1 - cos ω t +

sin ω t t − ω td td

F

For t > td

sin ωt d − sin ω (t - t d ) - cosωt DLF = ωt d

1

0

td

Murray, T.M. (1975) “Design to Prevent Floor Vibrations”, AISC Engineering Journal, Vol. 12, No. 3.

DM 03.10.00

9-29

ZAMIL STEEL BUILDINGS DESIGN MANUAL 10. Special design requirements

PEB DIVISION

CHAPTER 10: SPECIAL DESIGN REQUIREMENTS Special design requirements are to be considered in terms of section size limitations, design loads and deflection criteria. These requirements must be explicitly stated in the CIF. In case it is felt that such requirements are not specified in the CIF, the group supervisor must consult Customer Service Department to confirm the actual requirements. Following are some of those special requirements that have subsequent impact on the building design:

10.1. Royal Commission: Jubail and Yanbu jobs falling within Royal Commission jurisdiction must be designed in accordance with Royal Commission Codes of Practice as applicable. i) qs

Wind applications in accordance with 1985 U.B.C. Code. = 670 Pa (0.67kN/m2) for Yanbu = 830 Pa (0.83kN/m2) for Jubail Exposure C shall be used unless otherwise specified.

ii)

Use Seismic Zone 1.

iii)

Minimum "LL" on the Roof Cover (sheets and purlins) is 1.0 kN/m² and 0.57 kN/m² on he frames.

iv)

Roof panel deflection shall be limited to L/240.

10.2. Saudi Consolidated Electricity Company (SCECO): iii)

Maximum vertical deflection for rigid frames and purlins shall be Span/240 for "DL+LL"and span/360 for "LL"

iii)

Maximum vertical and lateral deflection of crane - runway beams shall be Span/1000.

iii)

ANSI/ASCE7-88/1990 code loading is usually specified.

10.3. Saudi Aramco: Aramco jobs should be designed for the following requirements: 1) 2) 3) 4)

Minimum roof live loads shall be in accordance with Uniform Building Code (UBC) 1994 edition. Wind loads based on Exposure Category C shall be used. All buildings shall be considered as essential facilities for selection of Importance factor I. Crane runway beams, support brackets and connections shall be designed for impact loads as follows: Maximum Vertical Wheel Load shall be increased by: 25% Maximum Lateral force shall be increased by: 20% Maximum Longitudinal force shall be increased by: 10%

DM 03.10.00

10-1

ZAMIL STEEL BUILDINGS DESIGN MANUAL 10. Special design requirements

PEB DIVISION

5) Serviceability Considerations (as per UBC 94): Horizontal sway:

a) EH/240 b) EH/375 c) EH/100

d) e) f) g) h) i)

Span/180 Span/120 Span/600 Span/400 Span/225 Span/450

For Buildings with cranes OR 50mm whichever is less. For Buildings with partitions walls and/or sensitive architectural elements attached to the building frame for Buildings without the above (bldg with metal panels, wall cladding & bare frames) Vertical and Lateral deflection of Girts Deflection of Wall Panels Vertical Deflection of TRC beam Lateral Deflection of TRC beam Vertical Deflection of JIB crane Vertical Deflection of Monorail & Under-hung & Monorail Crane Beams

Design calculation must include:

a) Check for combined axial and bending for purlins designed as struts in the bracing system b) Check for effect of eccentricity at the connection between bracing and strut purlins. 6) High strength bolts are to be black with a shank not fully threaded and shall confirm to ASTM A-325 Type I. 7) Web at brace rod connection must be stiffened. 8) Minimum thickness of built-up sections should be 5mm 9) Cables should not be used as roof and wall bracing. 10) Web to flange welding for all built-up members must be double sided 11) Shot blasting of primary and secondary members prior to special coating with Hempel’s Zinc Chromate Primer 1205-SA/222 Yellow (unless noted otherwise) 10.4. Jebel Ali Free Zone Authority (JAFZA) For jobs in Dubai, UAE, following are the general requirements pertaining to Dubai municipality:

i)

6 mm thick material is required for main frames, wind columns, endwall rafters, canopy rafters, mezzanine beams, joists, columns and portal frames. Only purlins, eave struts and girts can be cold-fromed sections.

ii)

Live load is 0.60 kN/m2

iii)

Wind pressure is 1.0 kN/m2 and 1974 MBMA is to be followed.

iv)

Purlins at roof to be designed for pattern loading.

DM 03.10.00

10-2

ZAMIL STEEL BUILDINGS DESIGN MANUAL 10. Special design requirements

PEB DIVISION

v)

Rod bracing at roof to be minimum of 20mm diameter. Strut tube to be used at roof and wall brace intersection (size 200x200x6mm)

vi)

Minimum of 2 braced bays in a building

vii)

Angle bracing to be used at sidewalls.

viii)

Galvanized sag rod 16mm diameter to be used for purlins, sidewall and endwall girts for bays of more than 4.5m. Use 1 row for bay spacing < 7.6m and 2 rows for bay spacing > 7.6m

ix)

Design calculations must include calculations substantiating gutter size and downspout used. Number of downspouts shall be limited to minimum number required by Design. Optimize the number of downspouts.

x)

Design calculations must include the section sizes of main frames and loading diagrams.

xi)

Primary members to be shot blasted to SA 2 ½ and painted with the following: Primer: SIGMA 7412 – 75 Microns Under Coat: SIGMA 7682 – 85 Microns Finish Coat: SIGMA 7688 – 80 Microns

xii)

Secondary members to be of galvanized finish.

xiii)

Minimum of 4 galvanized anchor bolts must be used for all columns

xiv)

Use metric system of units in drawings and calculations

xv)

Flange braces to have a minimum thickness of 4.0 mm

Drafting Requirements xvi)

Sizes of the built-up sections shall be shown

xvii)

Details of bolt connections of main frames shall be shown on cross section drawing

xviii)

40mm notch should not be shown on drawings

xix)

Ramp at door entrance location should not be shown

xx)

Grid enumeration shown on order sketch should be adhered strictly.

xxi)

Columns sectoins must be shown for all columns shown on the anchor bolt plan.

xxii)

Center to center dimensions of rigid frame columns, end wall columns and framed opening jambs must be shown on anchor bolt plan

DM 03.10.00

10-3

ZAMIL STEEL BUILDINGS DESIGN MANUAL 10. Special design requirements

PEB DIVISION

10.5. Dubai i) Minimum 6-mm thickness for main frame and mezzanine beams. Multispan intermediate columns can be of 150x150x4.5 square tube. Wind columns, endwall rafters and mezzanine joists can be of cold formed or I-sections of any thickness. ii)

Live Load: 0.60 kN/m² (unless noted).

iii) Wind pressure: 1.00 kN/m² and MBMA 1974 code should be used (unless noted otherwise). iv)

Cable bracing may be used at roof and sidewall.

v)

Sag rods should be used for purlins at bays > 8m (1 row per bay).

vi)

Secondary members to be of galvanized material.

vii)

Use of metric system of units in drawings and calculations

10.6. Sharjah i) Minimum 4-mm thickness for main frame and mezzanine beams. Wind columns, endwall rafters and mezzanine joists can be of cold formed or I-sections of any thickness. ii)

Live Load: 0.57 kN/m² (unless noted).

iii)

Wind Load: 0.75 kN/m² applied as per MBMA 1974 (unless noted).

iv)

Cable bracing may be used at roof and sidewall.

v)

Sag rods should be used for purlins at bays > 8.5m (1 row per bay)

vi)

Secondary members to be of galvanized material.

vii)

Use of metric system of units in drawings and calculations

Drafting Requirements viii) Sizes of the built-up sections shall be shown ix) Details of bolt connections of main frames shall be shown on cross section drawing x) 40mm notch should not be shown on drawings xi) Ramp at door entrance location should not be shown DM 03.10.00

10-4

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

10. Special design requirements

xii) Grid enumeration shown on order sketch should be adhered strictly. xiii) Columns sectoins must be shown for all columns shown on the anchor bolt plan. xiv) Center to center dimensions of rigid frame columns, end wall columns and framed opening jambs must be shown on anchor bolt plan 10.7. Abu Dhabi i) • •

Abu Dhabi Municipality did not allow the use of cold-formed sections for end wall posts. Two alternatives can replace it which are: Using built-up sections. Using hot-rolled sections.

iii) For main frames: Minimum web thickness = 4mm; Minimum Flange thickness = 6mm iii) Minimum thickness of purlin = 2mm 10.8. Vietnam: For all the Vietnam jobs, the maximum rainfall intensity of 150 mm/hr is to be used. 10.9. Shanghai China: For all Shanghai China jobs Seismic Zone 3 to be considered. 10.10. wind Speed in Saudi Arabian: The basic wind speed for determining wind pressures in different locations of Saudi Arabia are as follows: Location Basic Wind Speed (KM/H) Eastern Province 125 Al-Jouf 139 ‘Ar’Ar 154 Bishah 125 Hail 144 Hawtah 128 Jiddah 125 Jizan 130 Khamis Mushayt 125 Medina 139 Najran 125 Qasim 165 Qaisumah 157 Rafha 150 Riyadh 144 DM 03.10.00

10-5

ZAMIL STEEL BUILDINGS DESIGN MANUAL 10. Special design requirements

PEB DIVISION

Tabuk Turaif Yanbu

144 139 125

10.11. Egypt Jobs in Non-Free Zone Areas∗ The following are the design requirements for Egypt jobs: I. To provide a statement in the design calculations package that the method of calculation of web shear and buckling allowable stress is in accordance with the Egyptian Design Code requirements. II. Minimum plate thickness to be used for built up sections is 5 mm. III. Vertical deflection should be limited to: • Span/300 for frames and mezzanine beams under live load only. • Span/900 for crane beams IV. Angle bracing should be used for roof, walls as well as cranes. No cable braces are allowed. 10.12. Snow Loads Ground Snow Loads pg based on 50 year mean recurrence is presented for some prominent countries as follows. The ground snow data for USA is available in Appendix Section A22 of MBMA 1996 in detail. Snow data for countries Japan, Korea, Pakistan, Turkey, France, Germany, Greece, Iceland, Italy, Northern Ireland, Scotland, Spain, Canada and Greenland is available in Section A24 of Appendix. Here data for other countries is provided for Kazakhstan, Romania, Czech and Slovakia Republic. i) Snow Load for Kazakhstan City Name

Almaty Aqmola Aqtau Aqtobe Atyrau Dzhezkazgan Ekibastuz Koshetau Oral



pg (kN/m2) 0.70 0.70 0.50 0.70 0.70 0.70 0.70 1.00 0.70

City Name

Oskemen Pavlodar Qaranghandy Qostanay Qyzylorda Rudnyy Semey Shymkent Taldyqorghan

pg (kN/m2) 1.00 0.70 0.70 0.70 0.50 0.70 1.00 0.50 0.70

No Special requirements of free zone area

DM 03.10.00

10-6

ZAMIL STEEL BUILDINGS DESIGN MANUAL 10. Special design requirements

PEB DIVISION

ii) Snow Load for Romania

City Name

Abrud Adjud Agnita Aiud Alba Iulia Alesd Anina Arad Avrameni Azuga Babadag Bacau Baia De Arama Baia Mare Baia Sprie Baraolt Baicoi Baile Govora Baile Herculane Baile Olanesti Baile Tusnad Bailesti Bechet Beclean Beius Beresti Bicaz Bistrita Birlad Blaj Bocsa Boldestt-Scaeni Borsec Borsa Botosani Brad Brasov Braila Breaza Brezoi Bucuresti Budesti

DM 03.10.00

pg (kN/m2)

2.00 2.50 1.50 1.50 1.50 2.00 2.00 1.50 2.50 3.50 2.00 2.50 2.00 2.00 3.50 1.50 2.00 2.00 2.00 2.00 2.50 3.00 3.00 2.00 2.00 2.50 2.00 1.50 2.50 1.50 1.50 2.00 3.50 2.00 2.50 2.00 2.00 3.00 2.00 2.00 2.50 3.00

City Name

Buftea Buhusi Busteni Buzau Buzias Calafat Caracal Caransebes Carei Cavnic Calan Calarasi Calimanesti Cehu Silvaniel Cernavoda Chisineu-Cris Cisnadie Cimpia Turzh Cimpina Cimpulung Cimpulung Moldovenesc Cluj-Napoca Codlea Comarnic Comanesti Constanta Codsa Mica Corabia Costesti Cotnari Covasna Craiova Cugir Curtea De Arges Curtici Dahabani Dej Deta Deva Dorohoi Dr. Petru Groza Dragnesti – Olt

pg (kN/m2)

2.50 2.00 3.50 2.00 1.50 3.00 2.50 1.50 1.50 3.50 2.00 3.00 2.00 1.50 3.00 1.50 2.00 1.50 2.00 2.00 2.50 1.50 2.00 2.00 2.00 2.00 1.50 3.00 2.00 2.50 2.00 2.50 2.00 2.00 1.50 3.00 1.50 1.50 1.50 3.00 2.00 2.50

City Name

Dragasani Drobeta Tr. Severin Dumbraveni Eforie Nord Eforie Sud Fagaras Falticeni Faurei Fetesti Fieni Filiasi Focsani Galati Gaesti Gheorghieni Gherla Giurgiu Gurahont Gura Humorului Hateg Hirlau Hirsova Horezu Huedin Hunedoara Husi Ianga Iasi Ineu Isaccea Intorsura Buzaului Jimbolia Joseni Lipova Ludus Lugoj Lupeni Mangalia Marghita Macin Marasesti Medgidia

pg (kN/m2)

2.50 2.50 1.50 2.00 2.00 2.00 3.00 2.50 3.00 2.00 2.50 2.00 3.00 2.50 2.50 1.50 3.00 2.00 2.50 2.00 2.50 3.00 2.00 1.50 2.00 2.50 2.50 2.50 1.50 3.00 3.00 1.50 2.50 1.50 1.50 1.50 2.00 2.00 1.50 3.00 2.50 2.50

10-7

ZAMIL STEEL BUILDINGS DESIGN MANUAL 10. Special design requirements

PEB DIVISION

City Name

Medias Miercurea Ciuc Mizil Moinesti Moldova Noua Moreni Motru Nadlac Nasaud Navodari Negresti Negresti Oas Novaci Ocna Mures Ocna Subiului Ocnele Mari Odobesti Odorheiu Secuiesc Oltenita Oncesti Onesti Oradea Oravita Orastie Orsova Otelu Rosu Panciu Pascani Paltnis Petrila Petrosani Piatra Neamt Pitesti Pincota Plenita Ploiesti Plopeni Polovragi Predeal Radauti

DM 03.10.00

pg (kN/m2)

1.50 2.50 2.00 2.00 2.00 2.00 2.00 1.50 2.00 2.00 2.50 2.00 2.00 1.50 1.50 2.00 2.00 1.50 3.00 2.50 2.00 1.50 1.50 1.50 2.00 1.50 2.00 3.00 3.50 2.00 2.00 2.00 2.00 1.50 2.50 2.00 2.00 2.00 3.50 3.00

City Name

Rauseni Reghin Resita Risnov Roman Rosiori De Vede Rovinari RM.Sarat RM. Vilcea Rupea Salonta Satu Mare Sacele Saveni Savirseni Sebes Segarcea Semenic Sf. Gheorghe Sibiu Sighetul Marmatiei Sighisoara Simeria Sinaia Sinnicolau Mare Siret Singeroz Bai Slatina Slanic Slanic Moldova Slobozia Solca Sovata Strehaia Suceava Sulina Simleul Silvaneie Tasnad Techirghiol Tecugi

pg (kN/m2)

2.50 1.50 1.50 2.00 3.00 2.50 2.00 2.00 2.00 1.50 1.50 1.50 2.00 2.50 1.50 1.50 2.50 3.50 2.00 2.00 2.00 1.50 1.50 3.50 1.50 3.00 2.00 2.50 2.00 3.50 3.00 2.50 3.50 2.50 3.00 3.00 1.50 1.50 2.00 2.50

City Name

Tg. Bujor Tg. Carbunesti Tg. Frumos Tg. Jiu Tg. Lapus Tg. Logresti Tg. Mures Tg. Ocna Tg. Neamt Tg. Secuiesc Timisoara Tirgoviste Tirnaveni Topijta Topoloveni Tg. Magurele Tulcea Tandarei Tigleni Uricani Urlati Urziceni Vaslui Vascau Vatha Dornei Valenh De Munte Victoria Videle Viseu De Sus Vinju Mare Vlahita Voineasa Vulcani Zalau Zarnesti Zimnicea Zlatna

pg (kN/m2)

2.50 2.00 2.50 2.00 2.00 2.00 1.50 2.00 2.50 2.00 1.50 2.00 1.50 2.50 2.00 3.00 2.50 3.00 2.00 2.00 2.00 2.50 2.50 2.00 3.50 2.00 2.00 2.50 2.00 3.00 2.00 3.50 2.00 1.50 2.00 3.00 2.00

10-8

ZAMIL STEEL BUILDINGS DESIGN MANUAL 10. Special design requirements

PEB DIVISION

iii) Snow Load for Czech and Slovakia Republic

City Name

As Banovce Banska Bystrica Banska Stravnica Bardejov Benesov Beroun Blansko Boskovice Brandys nad Labem BRATISILAVA Breclav Brezno Brilina BRNO Broumav Bruntai Cadca Calovo Caslav Ces. Teisn Ceska Kemenice Ceska Lipa Ceska Trebova CESKE BUDEJOVICE Cesky Krumlov Cheb Chocen Chomutov Chotebor Chrudim Churdim Ciemy Balog Decin Delva Domazlice Dooruska Dubi Dubnica Dubuny Duchcov

DM 03.10.00

pg (kN/m2)

1.50 0.70 1.00 1.50 1.00 0.70 0.50 0.50 0.70 0.50 0.70 0.50 1.50 0.50 0.50 1.00 1.50 1.50 0.70 0.50 0.70 0.70 0.50 0.70 0.70 0.70 0.70 0.70 0.50 1.00 0.50 0.50 1.60 0.50 1.00 0.50 0.70 1.50 0.70 0.50 0.50

City Name

Dunajska Streda Dvory Dvur Kralove nad Labem Filakovo Frydek Mistek Frydiant Galanta GOTTALDOV Handlove Hardec Kralove Havlickuv Brod Hlinsko Hlonovec Hlucin Hodonin Holesov Holic Horice Horice Horovice Hranice Hronov Humerine Humpolec Ivancice Jablonec nad Nisou Jaromer Jesenic Jicin Jindrichuv Hradec Jirkov Kadan Kanory KARVINA Kezmarok Kladno Klatovy Kojetin Kolarovo Kolin KOSICE

pg (kN/m2)

0.70 0.70 0.70 0.70 0.70 0.70 0.70 0.50 1.00 0.50 1.00 1.50 1.00 0.50 0.50 0.50 0.50 0.70 0.70 0.50 0.50 1.00 0.70 1.00 0.50 1.50 0.50 1.50 0.50 0.70 0.70 0.50 1.00 0.70 1.00 0.50 0.50 0.50 0.70 0.50 0.70

City Name

Koslelec Kostelec nad Orlici Kralone Kraslice Kravare Krnov Krombachy Kromeriz Krupina Kunta Hora Kunta Hora Kyjov Kynsperk nad Ohri Levice Levoca LIBEREC Lipnic and Becon Liptovsky Mikulas Litomerice Litomyst Litovel Litvinov Louny Lovosice Lucence Lysa nad Labem Malacky Marianske Lazne Martin Michalovce Mikulov Milevsko Mimon Mlada Boleslav Modrany Moheinice Moravske Budejovice Most Myjava Nachod Nejdek

pg (kN/m2)

0.70 0.70 0.70 1.60 0.50 0.70 1.00 0.50 0.70 0.50 0.50 0.50 0.70 0.70 1.00 1.50 0.50 0.70 0.50 0.70 0.50 0.70 0.50 0.50 0.70 0.50 0.50 1.00 1.00 0.70 0.50 0.70 0.70 0.50 0.50 1.00 0.50 0.50 1.00 0.70 1.60

10-9

ZAMIL STEEL BUILDINGS DESIGN MANUAL 10. Special design requirements

PEB DIVISION

City Name

Nitra Novaky Nove Mesto Nove Zanky Novy Novy Bor Novy Bydzov Novy Jicin Nymburk Nyrany OLOMOUC Opava Orlova OSTRAVA Ostrov Otrokovice PARDUBICE Partizanska PAUBICE Pelhrimov Pezinok Piestany Pisek PLZEN Podebrady Podebrady Podunajske Biskupice Policka Poprad Povazska Bvstrica PRAHA (PRAGUE) Prelouc Prerov Presov Pribor Pribram Prievidza Prostejov Puchov Rakovnik

DM 03.10.00

pg (kN/m2)

0.70 0.70 0.70 0.70 0.50 1.00 0.50 0.70 0.50 0.50 0.50 0.50 0.70 0.50 1.00 0.50 0.50 0.70 0.50 1.00 0.70 0.70 0.50 0.50 0.50 0.50 0.70 1.00 1.00 1.00 0.50 0.50 0.50 0.70 0.70 0.70 1.00 0.50 0.70 0.50

City Name

Ricany Roudnice nad Labem Roznava Rumburk Ruzornberok Rychnov Rychnov nad Kneznov Rymarov Sabinov Sala Secovce Sered Skalica Slany Snina Sobeslav Sobota Sokolov Spisska Nova Ves Stara Tura Sternberk Strakonice Stranice Sumperk Supava Svil Svitavy Tabor Tachov Teplice Tisnov Topolcany Trebic Trebisov Trebon Trencin Trest Trnava Turnov Turzovka

pg (kN/m2)

0.70 0.50 1.00 1.00 1.00 0.70 0.70 1.50 0.70 0.70 0.70 0.70 0.50 0.50 1.00 0.50 0.70 0.70 1.00 1.00 0.70 0.50 0.50 1.00 0.70 1.00 0.70 0.70 0.70 0.50 0.50 0.70 0.70 0.50 0.50 0.70 1.00 0.70 0.70 1.50

City Name

Twdosovce Uherske Hradiste Uhersky Brod Unicov USTI nad Labem Usti nad Orl. Val Mezinci Varnsdorf Velke Mezirici Veseli nad Moravon Vlasim Vodnany Vranov Vrchlabi Vrutky Vselin Vsetin Vyskov Vysoke Myto Zabneh Zatec Zbraslav Zdar nad Saz Zian natlr Zilina Zlate Moravce Znojmo Zoztoky Zvolen

pg (kN/m2)

0.70 0.50 0.50 0.50 0.50 0.70 0.70 1.00 0.70 0.50 0.70 0.50 0.70 1.50 1.50 1.60 0.70 0.50 0.50 0.70 0.50 0.50 1.50 1.00 1.00 0.70 0.50 0.50 1.00

1010

ZAMIL STEEL BUILDINGS DESIGN MANUAL 11. Special buildings

PEB DIVISION

CHAPTER 11: SPECIAL BUILDINGS 11.1. Car Canopies Car parking shelter buildings are simple open buildings, providing maximum open space for vehicles movement with fewer columns. Generally vertical or curved fascias are added to enhance aesthetics. The following are the types frames adopted based on the covered width and accessibility. i) Gazelle iii) Falcon I v) Butterfly I Vii) Caracal

ii) Cheetah iv) Falcon II vi) Butterfly II

Gazelle

DM 03.10.00

Cheetah

11-1

ZAMIL STEEL BUILDINGS DESIGN MANUAL 11. Special buildings

PEB DIVISION

Falcon I

Butterfly I

DM 03.10.00

Falcon II

Butterfly II

11-2

ZAMIL STEEL BUILDINGS DESIGN MANUAL 11. Special buildings

PEB DIVISION

Caracal

Butterfly canopies must not be used at snow accumulation territories. Caracal canopy is not commonly used since it offers a hindrance in the movement of cars, thus the space is not effectively utilized. Since no portal bracing is allowed in this type of buildings, columns are stiffened in minor axis in order to withstand the longitudinal wind loading in lieu of wall bracing. Since minor axis bending requires the columns to have fixity at bottom in the minor axis, columns are straight prismatic builtup members with fixed base. Except Gazelle and Caracal canopies, other canopies are fixed in both major and minor axis directions. Loading: Car canopies are designed for dead, live and wind loading; snow and seismic loading is applied if required. In case of snow loads, fascias are not provided to avoid snow accumulation. Since such buildings are lightweight, seismic force generally does not govern. Live Load: For Gazelle, Falcon (T type) and Butterfly (Y type) canopy live load is applied in three cases. One case of uniform load of 0.57kN/m2 on the whole rafter and the other case of an unbalanced live load of 0.57kN/m2, which is applied on only on side of the rafter with respect to ridge. The third case is to apply an unbalanced load of 2kN at the end of the rafter (at eave) on one side only. The live loads are summarized as below

DM 03.10.00

11-3

ZAMIL STEEL BUILDINGS DESIGN MANUAL 11. Special buildings

PEB DIVISION

i) ii) iii)

Dead Load + Live Load (full width) Dead Load + Live Load (on half width) Dead Load + 2kN (@ edge)

For Cheetah Canopy load case (ii) and for Caracal Canopy both (ii) and (iii) are not applicable. Wind Load: Since the car shelter buildings are open buildings, the GCp coefficient is -0.7 a uniform suction at roof for all wind load cases i.e., wind left, wind right and wind end. However for the roof sheeting and purlins GCp coefficient should be determined from Table 5.5(b) of MBMA 1996 manual for Overhang Coefficients for components and Claddings. Buildings with Fascia: Buildings with fascia will be subjected to additional dead loads and wind loads. Note that the GCp coefficient for fascia is +1.3 on windward side and –1.3 on leeward side. Allowable Deflection The maximum allowable vertical deflection at the free end of the cantilever shall be limited to L/90, where L is the distance from the centerline of the column to the free end of the cantilever. Maximum allowable horizontal deflection in both minor and major axis direction is limited to EH/45. Allowable Stresses ASFAD detail level input should be used to model the frame. The following are design parameters used in the input: For Column Kx = 2.1 (effective length factor in the major axis direction) Ky = 1.0 (effective length factor in the minor axis direction) Lx = Column Height (unbraced length in the major axis direction) Ly = Column Height (unbraced length in the major axis direction) Cb = 1.0 (conservatively) For Rafter Kx = 2.1 (effective length factor in the major axis direction) Ky = 1.0 (effective length factor in the minor axis direction) Lx = Rafter Length (unbraced length in the major axis direction) Ly = Spacing of flange brace points Cb = 1.0 (conservatively)

DM 03.10.00

11-4

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

11. Special buildings

For load combinations including wind load, the allowable stresses are increased by 33%. This is achieved by using a stress reduction factor as load factor of 0.75 for those load combinations containing the wind load. Minor Axis bending The force acting on the fix-based column due longitudinal wind should be calculated as per the procedure outlined in clause 7.1.3 In the presence of fascias the increased projected area will give rise to higher longitudinal wind loads. This force is applied at top of the column in the minor axis direction. The analysis of the column (rotated by 900) is performed by defining the member as ‘H’ in the ASFAD input. Minor axis bending resistance requires the wider and thicker column flanges. Special Case An exceptional case may be that the sheeting is provided at the car canopy columns. In such case the rafter will experience an additional load due to pressure underneath the roof. The GCp values for the rafter should be evaluated as per Table 5.5b for Overhang Coefficients for Components and Claddings as per the tributary area of the rafter, which approximately works out to be -1.3. Service / Fuel Stations Service stations are similar to parking buildings. The distinguishing features of Zamil Steel service stations over vehicle parking shelters are: • • • •

Tubular Columns Flat Soffit Vertical Fascias Exposed pedestal, base plate and anchor bolts

DM 03.10.00

11-5

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

11. Special buildings

11.2. Poultry Buildings Zamil Steel poultry buildings were developed specifically for the poultry industry and are designed to accommodate the equipment and ventilation systems normally required for this specific application. The following are the main features of poultry buildings: i) Structural steel members are galvanized. If cold-formed members are used, these are formed from galvanized coil. If built-up members are used, these are hot dip galvanized after satisfying the size limitations outlined in Plate 8 (page1.54 of section 1.8) ii) Galvanized steel or Aluminum panels iii) Galvanized steel or Aluminum liners iv) Electro-galvanized connection machine bolts v) Corrosion resistant panel fasteners vi) 100mm thick fiberglass insulation vii) Weather tight neoprene foam closures Frame Configuration Frame type is clear span. Span varies from 12m to 15m. Bay spacing: If built-up members are used for main framing, standard bay spacing is 6m. If cold-formed members (C sections: single or double) are used for main framing, standard bay spacing is 2.5m. Roof Slope: Roof Slope is 2:10 Eave Height: Eave height is calculated based on the clear height of 2.5m.Normally the eave height ranges from 2.7m to 3m. Both end walls are post & beam. Loading Live Load: Standard live load on frame is 0.35kN/m2, however it is subject to change as per customer’s requirement to the maximum of 0.57kN m2. On roof the maximum live load is 0.57kN m2. Dead Load: Dead load is taken as self weight of panels, purlins and liner together as 0.15kN/ m2. Collateral Load: The collateral load generally varies between 0.1kN/ m2 and 0.25kN/ m2 depending upon the loads supported to purlins. Secondary Framing Normally the purlins are flush and girts are by-pass, however these can be used in any combination that would give the best economy. Flush purlins can support the liner panel, hiding the main framing. In such a case straight prismatic members shall be used. If columns are designed as unbraced, then flush girts can be used too. Again economy will govern the decision. Generally for a bay spacing of 2.5m-3.0m with a cold-formed main framing is suitable for flush purlin/girt system. By pass construction is more economical for 6m bay spacing. Special Design Features DM 03.10.00

11-6

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

11. Special buildings

Tie-Member: A tie member is provided for extra stability and stiffness of frame, if cold-formed main framing is used which is shown below.

Ventilation Hood: The hood on one sidewall is provided all along the length except the first two bays and the last bay in order to ventilate the fresh air from one side. At other sidewall windows are provided to ventilate the air. A typical framing with hood is shown below.

Framing of hood is designed by using either cold-formed (C sections) or using doubles angles back to back.

DM 03.10.00

11-7

ZAMIL STEEL BUILDINGS DESIGN MANUAL 11. Special buildings

PEB DIVISION

11.3. Bulk Storage Buildings Grain storage buildings are normally Clear Span buildings characterized by a steep slope (30o – 45o) that permits the efficient storage of piled granular material above the building eave height. Grain storage buildings have concrete bearing walls all around that supports grain loads and are designed as retaining walls as shown in the following sketch. This kind of arrangement does not impose grain loads on the steel framing and liners and results in an economical solution. Alternatively the reinforced concrete wall can have certain height and the steel frame column can be anchored above the wall.

However if customer requires steel walls to support the grains adequate wall liner panel must be provided to transfer the load to the wall girts and, in turn, to the rigid frame column. In such cases type ‘A’ liner panel is recommended. The pressure of the grains on the walls has a triangular distribution with a maximum pressure value at the base, p, equal to Cwh. Where, p = Cwz (pressure at level z in kN/m²) C = cos²α (coefficient of active pressure for a positive surchage) = w = α = z =

DM 03.10.00

1−sinα 1+sinα

(coefficient of active pressure for a level fill)

Density of material (kg/m3) Angle of repose ≈ Angle of Internal Friction Depth of Grains at which pressure is calculated measured from top

11-8

ZAMIL STEEL BUILDINGS DESIGN MANUAL 11. Special buildings

PEB DIVISION

Granular Material Properties Granular Material Wheat Maize Barley Oats Rye Corn Peas Beans Flour Sugar Coal Ashes Cement Lime Potatoes

Angle of Internal Friction ‘φ φ’

Angle of Repose ‘α α’

Density ‘w’ (kg/M3)

26 26 31 33 29 35 34 33 --35 35 10 ---

25 25 25 25 24 32 30 27 40 35 35 45 15 35 --

880 810 740 590 760 760 750 840 440 1000 910 710 1410 1000 660

Design The design of a grain storage building involves designing the following items for lateral grain pressure: • Girts • Liner Panel • Main Frame • Wind Columns The design steps are illustrated in the following example. Example: Frame Type: Clear Span Width: 24m Eave Height: 5.4m 12 Bays @ 5.0m Roof Slope: 300 The building is to be used for wheat storage. All walls are fully sheeted. Maximum height of wheat = 4m on the walls. Solution: Density of wheat = 880 kg/m3. DM 03.10.00

11-9

ZAMIL STEEL BUILDINGS DESIGN MANUAL 11. Special buildings

PEB DIVISION

Assume the most critical condition that is of positive surcharge. For positive surcharge the coefficient of active pressure is C = cos²α Using angle of repose for wheat α = 25o ⇒ C = cos225o = 0.8214 Pressure, p = 0.8214x8.8x4 = 28.91kN/m2 i) Girt Design Assume the girts are located at 0.4m, 0.9m, 1.5m, 2.2m, 3.0m and 4.0m. Locations of dotted lines that demarcate the tributary heights of girts are 0.2m, 0.65m, 1.2m, 1.85m, 2.6m and 3.5m. The pressures at dotted lines are calculated as: At 0.20m ⇒ At 0.65m ⇒ At 1.20m ⇒ At 1.85m ⇒ 15.54kN/m2 At 2.60m ⇒ 10.12kN/m2 At 3.50m ⇒ 3.61kN/m2

p1 = 0.8214x8.8x3.8 p2 = 0.8214x8.8x3.35 p3 = 0.8214x8.8x2.8 p4 = 0.8214x8.8x2.15

= 27.47kN/m2 = 24.21kN/m2 = 20.24kN/m2 =

p5 = 0.8214x8.8x1.4 = p6 = 0.8214x8.8x0.5 =

Uniformly distributed load at girts are calculated as follows: At first girt: q1 = 0.5x(p1+p2)x0.45 = 11.6kN/m At second girt: q2 = 0.5x(p2+p3)x0.55 = 12.2kN/m At third girt: q3 = 0.5x(p3+p4)x0.65 = 11.6kN/m At fourth girt: q4 = 0.5x(p4+p5)x0.75 = 9.62kN/m At fifth girt: q5 = 0.5x(p6)x0.50 = 0.9kN/m Girts should be designed for these pressures and pressures combined with wind pressure/suction.

DM 03.10.00

11-10

ZAMIL STEEL BUILDINGS DESIGN MANUAL 11. Special buildings

PEB DIVISION

ii) Liner Panel Design Allowable load table is provided for Type ‘A’ panel for very small spans ranging from 0.1m to 1.0m in order to assess the panel capacity accurately. Allowable Load for Type ‘A’ panel for grain pressure Panel Thickness mm 0.50

0.60

0.70

Number of Spans

Load Case

0.10

0.20

0.30

0.40

1 2 3 1 2 3 1 2 3

pressure pressure pressure pressure pressure pressure pressure pressure pressure

237.80 190.24 198.56 371.60 297.28 310.29 509.00 407.20 425.02

88.00 92.00 99.28 122.00 116.00 145.00 150.00 142.00 177.50

39.11 40.89 51.11 54.22 51.56 64.44 66.67 63.11 78.89

22.00 23.00 28.75 30.50 29.00 36.25 37.50 35.50 44.38

Span in meters 0.50 0.60 14.08 14.72 18.40 19.52 18.56 23.20 24.00 22.72 28.40

9.78 10.22 12.78 13.56 12.89 16.11 16.67 15.78 19.72

0.70

0.80

0.90

1.00

7.18 7.51 9.39 9.96 9.47 11.84 12.24 11.59 14.49

5.50 5.75 7.19 7.63 7.25 9.06 9.38 8.88 11.09

4.35 4.54 5.68 6.00 5.73 7.16 7.20 7.01 8.77

3.45 3.68 4.60 4.38 4.64 5.80 5.25 5.68 7.10

Using Type ‘A’ panel of 0.7mm thickness can satisfy the following pressure requirements. For 0.4m span ⇒ For 0.5m span ⇒ For 0.6m span ⇒ For 0.7m span ⇒ For 0.8m span For 1.0m span

p1 = 27.47kN/m2 p2 = 24.21kN/m2 p3 = 20.24kN/m2 p4 = 15.54kN/m2 ⇒ p5 = 10.12kN/m2 ⇒ p6 = 3.61kN/m2

iii) Wind Column Design

DL+WIND+GRAIN

DL+LIVE+GRAIN

iv) Main Framing

DM 03.10.00

11-11

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

11. Special buildings

Main frame should be designed for the following loading conditions: • • • •

DL+LL+Grain(@ Both Columns) DL+LL+Grain(@ One Column) DL+WL+Grain(@ Right Column) DL+WR+Grain(@ Left Column)

The gain load should be applied as triangular loading in ASFAD loading input. Note: For bay spacing > 6m, using soldier column with a tie beam at top to transfer the lateral grain load to main rigid frame columns would result in great savings in the girts.

DM 03.10.00

11-12

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

11. Special buildings

11.4. Hangar Buildings Aircraft hangar buildings are characterized by large clear span widths (48m to 84m) and very high eave heights (24m to 36m). Beyond 84m pre-engineered buildings can not be effectively utilized as hangar buildings and in such cases structural steel truss system is adopted. A hangar door is not within the scope of Zamil Steel supply that typically consists of several electrically controlled steel framed door leaves which telescope into covered pockets on one side or (mostly) on both sides of the building. The weight of a hangar door is supported on wheels traveling on a steel rail that is recessed below the finished floor level. Thus the supporting system shall be designed to withstand the lateral loads from the door at the location of door guides. Wind load and gravity load deflections are major factors in the design of a building with a hanger door. Deflection values of the supporting frames of the door are extremely important and must be defined to the door manufacturer as they represent an important design input for the hangar door. Vertical deflection of supporting rigid frames is limited to a maximum of +10.0cm and it has to be reported in the design calculation package. The supporting system for the doors may be designed in two ways: i) Provide cantilevered members from the end frame where the top guides of the door will be supported. This system is usually provided for light to medium weight doors (up to 6m height). ii) Provide two end frames with horizontal members in between which will support the door guides. This system of framing is provided for heavy-duty doors (over 6m in height). The spacing between the two end frames is generally 2.0m to 3.0m. The door pockets may be located within the same width of the building or they may be housed outside the building width in a structure similar to a lean-to. Outside pockets allow for a wider door opening. A typical hangar door supporting structure is shown in the sketch below, that not only accommodates the door guides but also acts like an endwall fascia support. The bracing should be broken at the support points throughout the building. This supporting system should be designed to resist the lateral wind forces from the door and fascia and transfer the loads to the longitudinal bracing system. The main elements that are required to be designed are the angle bracing and the strut tube. The details of door header, force distribution and the analysis are shown in the following sketch.

DM 03.10.00

11-13

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

11. Special buildings

Force in each hangar door support, P = End Wall Area x q x GCp /(2n) q = velocity pressure kN/m2 GCp = 1.0 n = number of supports Force in the angle, F = P/cosθ = P x H/√H2+V2 Force in the strut tube = P

DM 03.10.00

11-14

ZAMIL STEEL BUILDINGS DESIGN MANUAL 12. Miscellaneous services

PEB DIVISION

CHAPTER 12: MISCELLANEOUS SERVICES 12.1. Drainage A proper roof drainage system is essential part in a building design that can ensure durability of the roof system of a building by preventing overflow of water at the sides of the building. The design of a drainage system is governed by both the gutter and downspout capacities. Gutter Capacity For gutter capacity, a formula derived from the Copper Development Association Inc. is used. 28 13

16 13

10

 334,500  13 D s = 19B M    CWI 

where, Ds

= downspout spacing in (m)

B

= average width of gutter in (m)

M

= depth/width of gutter

W

= width of area being drained in (m)

A

= area of downspout in (cm2)

I

= maximum rainfall intensity in (mm/hr) [as per ZS standard I = 150mm/hr] **

C

= roof slope constant = 1.00 for roof slope from 0.0:10 to 2.0:10 = 1.10 for roof slope from 2.1:10 to 5.4:10 = 1.20 for roof slope from 5.5:10 to 8.2:10

**Reference:

= 1.30 for roof slope from 8.3:10 and higher Time Saver Standards for Architectural Design Data by John Hancock Calendar, 1974, page 384.

Downspout Capacity Downspout spacing based on downspout capacity is calculated as follows:

Ds =

440A CWI

Choice of downspout spacing Downspouts should be provided only at main frame column's locations for the following reasons: 1. Aesthetics of the building (to give a better appearance). 2. To avoid fouling of downspouts with any openings on the walls (for windows, slide doors etc.). 3. To make provision of downspout supports easier, in case of canopies or roof extension at side walls. Accordingly for small buildings downspouts may be provided every alternate bay as needed by design

DM 03.10.00

12-1

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

12. Miscellaneous services

The standard eave gutter, valley gutter and downspout are shown as follows:

Example 1: Using the standard Oasis gutter and standard downspout, calculate the maximum downspout capacity.

DM 03.10.00

12-2

ZAMIL STEEL BUILDINGS DESIGN MANUAL 12. Miscellaneous services

PEB DIVISION

B = 0.170 m M = 0.154/0.170 = 0.91 W = 30/2 = 15m C = 1.0 (Assume Slope 1:10) I = 150mm/hr A = 73 x 105 = 76.65cm2 Gutter capacity:

D s = 19 x(0.17)

28 13

16 13

10

 334,500  13 x (0.91)   = 17.45m  1.0 x 15x150 

Downspout capacity: Ds = 440 x 76.65 / [1.0 x 15 x 150] = 14.99m ⇒ governs, Use 14m Example 2:

Using the standard valley gutter and downspout, calculate the maximum downspout spacing. B = 0.4 m M = 0.19 / 0.4 = 0.475 W = X + Y = ½ (36 m) + ½ (36 m) = 36 m C = 1.0 (Assume Slope 1:10) I = 150mcm/hr A = 314.2cm2

DM 03.10.00

12-3

ZAMIL STEEL BUILDINGS DESIGN MANUAL 12. Miscellaneous services

PEB DIVISION

Gutter capacity: 28 13

10

16 13

 334,500  13 D s = 19 x(0.4) x (0.475)   = 25.25m  1.0 x36x150  Downspout capacity: Ds = 440 x 314.2 / [1.0 x 36 x 150] = 25.6m ⇒ Use 25m Gutter Capacity Tables 14.1 Oasis Eave Gutter at eave Building Width to be Drained (X) (m)

Maximum Downspout Spacing Ds (m)

≤6.0 7.0-9.0 10.0-12.0 13.0-15.0 16.0-18.0 19.0-21.0 22.0-24.0 27.0-30.0 33.0-36.0 39.0-45.0 48.0-60.0

28.0 20.0 15.0 12.0 10.0 8.0 7.0 6.0 5.0 4.0 3.0

Valley Gutter at common eave heights Building Width to be Drained W=X+Y (m) ≤12.0 13.0-18.0 19.0-24.0 25.0-30.0 31.0-36.0 37.0-42.0 43.0-48.0 49.0-54.0 55.0-60.0 61.0-66.0 67.0-72.0 73.0-84.0 85.0-96.0 97.0-108.0 109.0-120.0

DM 03.10.00

Maximum Downspout Spacing Ds (m)

48.0 35.0 28.0 24.0 21.0 18.0 16.0 14.0 12.0 11.0 10.0 9.0 8.0 7.0 6.0

12-4

ZAMIL STEEL BUILDINGS DESIGN MANUAL 12. Miscellaneous services

PEB DIVISION

Valley Gutter at high/low buildings Building Width to be Drained W=X+Y (m) ≤12.0 13.0-18.0 19.0-24.0 25.0-30.0 31.0-36.0 37.0-42.0 43.0-48.0 49.0-54.0 55.0-60.0 61.0-66.0 67.0-72.0 73.0-84.0 85.0-96.0 97.0-108.0 109.0-120.0

Maximum Downspout Spacing Ds (m) 45.0 33.0 26.0 22.0 19.0 17.0 15.0 14.0 12.0 11.0 10.0 9.0 8.0 7.0 6.0

Notes: Tables are based on 150mm/hr maximum rainfall intensity. Tables are based on the standard sizes of gutters and downspout. Coil thickness for Valley gutter is 1.0mm; 0.5mm for eave gutters and downspouts. Roof slope is < 2:10 Formulae are adopted from Copper Development Association Inc.

DM 03.10.00

12-5

ZAMIL STEEL BUILDINGS DESIGN MANUAL 12. Miscellaneous services

PEB DIVISION

Drainage Design Program Downspout spacing can be quickly evaluated by using the drainage design spreadsheet software available in the design calculation package. Following is a sample calculation shown.

Width of Drained Area (Left) Width of Drained Area (Right) Total Width of Drained Area ' W '

30.00 24.00 54.00

Roof Slope

1.00 :10

Rain Fall Intensity ' I '

150.00

Gutter Type Gutter Average Width ' B ' Gutter Depth / Width ' M '

Meter Meter Meter

mm per Hour

Common Eave Valley Gutter 0.40 Meter 0.48 314.15

Downspout Area ' A '

Roof Slope Slope 0.0> 10.0

Constant ' C ' C 1.00 1.10 1.20 1.30

cm 2

Required Down Spout Spacing ' DS ' The following Calculations are based on Formulas derived by: "The Copper Development Association Inc." Based on Gutter Capacity DS= 19 (B)28/13 (M)16/13 (334500 / CWI)10/13 DS= 15.40 Meter Based on Down Spout Capacity DS= 440 A / CWI DS= 14.22 Meter Maximum Down Spout Spacing Use Single Down Spouts

DM 03.10.00

@

14.22

Meter Meter Spacing

12-6

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

12. Miscellaneous services

12.2. Natural Lighting Maintaining a reasonable level of lighting inside a building by natural day light, by artificial (electric) lighting or by a combination of both is an essential requirement of building usage. Balancing of natural daylight with electric lighting is an economic issue. Determining the amount of natural daylight inside a building depends on many variables, some of which are building location, time and day of the year, local environmental conditions and size and location of translucent panels and windows relative to the building shell. Several procedures for calculating daylight lighting levels inside a building were developed in the past. A simple yet reasonably accurate method is the daylight factor method. Zamil Steel has adopted this method because of its worldwide acceptance and ease of application. Although this method was primarily developed for overcast sky conditions, it can also be used effectively for clear sky conditions. The Daylight Factor Method The daylight factor (DF) for a spot inside a building is a ratio of the interior horizontal illumination at that spot to the simultaneous external horizontal illumination. The advantage of this method lies in the fact that, since it is based on uniform overcast sky the exterior daylight is a constant that is independent of time of day or day of the year. This does not imply that the interior illumination is a constant; rather it is a constant fraction of the changing exterior illumination. This method is best understood through the example on the following page.

DM 03.10.00

12-7

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

12. Miscellaneous services

Example Consider an industrial building located at 30O N with the following building configuration: 30m wide, 75m long (10 bays at 7.5m), 8m eave height used as Auto Repair Garage. Determine the number of Zamil Steel roof skylights that will provide suitable natural daylight during 85% of the hours between 9:00 and 17:00 whereby the recommended level of illumination will be achieved or exceeded. Solution: 1. The daylight factor can be selected directly from tables or calculated from the exterior and interior horizontal illumination tables. Ei Ex

= Interior level of Illumination = 1100 Lux (Table 1) = Exterior Illumination = 12800 Lux (Figure 1)

2. Required Daylight factor, DFr = Ei/Ex = 1100/12800 = 8.6% 3. Select Light Loss Factor, Lf = 0.70 (Industrial/sloped Roof). 4. Use Zamil Steel skylights with a light transmittance value of t = 80% 5. Design Daylight factor DF = DFr/(Lf t) = 8.6/(0.7 X 0.8) = 15.4% 6. For a building length/height ratio (L/H) of 75/8 = 9.375 and Daylight Factor DF = 15.4% enter Figure No. 2 where: Ratio of glass area, Ag to floor area, Af : r = Ag/Af = 0.2 7. Ag = r x Af = 0.2 x (75x30) = 450m2 8. Number of skylight panels, N = Ag/As = 450/(3.25x0.9) = 154 where As = Net area of one roof skylight panel 9. Final Design: • • •

Use a minimum of 154 Zamil Steel Skylights. Distribute evenly on both sides of building ridge. Space skylights such that the spacing shall not exceed twice the roof height in both directions.

DM 03.10.00

12-8

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

DM 03.10.00

12. Miscellaneous services

12-9

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

12. Miscellaneous services

12.3. Ventilation The primary purpose of ventilation is the control of the interior environment of the building by the removal/reduction of: • Heat buildup thus providing comfort for workers, preserving goods and enabling equipment to function properly. • Gaseous by-products (the result of some manufacturing processes) thus providing a healthier atmosphere for workers. • Flammable fumes thus minimizing fire hazards (ventilation is also important after a fire has started at which time it helps in removing the fumes and smoke), and improving visibility for escapees and fire fighters. Ventilation must not be confused with air conditioning. Ventilation, whether natural or forced, does not have heat reduction characteristics. If a cooler temperature is desired ventilation alone will not suffice and air conditioning must be considered. Ventilation equipment comes in two categories: Inlet equipment and outlet equipment. Either one can be natural or forced (power).

The planning and correct distribution of ventilation equipment has a major role in the overall efficiency of the ventilation system. Ventilation efficiency is also affected by the location of equipment, partitions and doors inside a building. A detailed study of ventilation must be made at the planning stage of the building. For complex buildings, determining ventilation requirements may require vast calculations and computer modeling. Much simpler procedures normally suffice for typical pre-engineered buildings. There are two simple and practical methods for determining ventilation requirements: • The Air Change Method, which is based on a recommended rate of air changes per hour for different building usages when ventilator capacity is given. • The Heat Removal Method, which calculates the volume of air required to remove the heat gain inside a building. These methods are good tools to approximate the ventilation requirements of the building. More detailed and accurate ventilation plans should be sought by contracting ventilation specialists directly.

DM 03.10.00

12-10

ZAMIL STEEL BUILDINGS DESIGN MANUAL 12. Miscellaneous services

PEB DIVISION

12.3.1. Ventilation Design Using Air Change Method Quantity of ventilators, QV is evaluated as follows:

VxN Q = v R x 3600 where, R = V = N =

Exhaust capacity (m3/s) Building volume (m3) Air change per hour

In the table below, enter the stack height, which is the average of the eave height and the ridge (peak) height. Enter the temperature difference between the inside and outside of the building. Read the equivalent required total exhaust capacity in m3/s. Stack Height (m)

Temperature Difference (°°C)

ZRV 300

ZRV 600

3

5

0.779

1.559

5

0.916

1.832

10

1.109

2.218

5

1.021

2.041

10

1.257

2.514

15

1.438

2.876

10

1.382

2.763

15

1.591

3.182

10

1.492

2.983

15

1.726

3.452

6

9

12 15

The number of recommended air changes per hour is obtained from the following table: Type of Building Warehouses, Factories, Dining Rooms, Machine Shops, Engine Rooms, Textile Mills, Wood Working Shops Boiler Rooms, Paint Shops, Garages, Schools Buildings with fumes, Kitchens, Paper Mills, Textile Mills, Dye Houses

DM 03.10.00

N = Recommended Air Changes Per Hour From To 5

10

10

15

15

20

12-11

ZAMIL STEEL BUILDINGS DESIGN MANUAL 12. Miscellaneous services

PEB DIVISION

Finally, apply the equation, at top of the page, to determine the number of required ventilators. For efficient functioning of the ventilation system the free inlet area (permanent openings plus the effective area of the louvers) must be greater than 150% of ventilation area. 12.3.2. Ventilation Design Using Heat Removal Method Calculate the total heat gain (H) in the building:

H = where,

Hl Hi Hs Hs

Hs + Hl + Hi = = = =

Heat gain from lighting Heat gain from internal equipment, people, etc. Solar Heat Gain AxIxaxe

where, A = Roof Area I = Actual Solar Radiation striking the roof surface (= 0.945 kW/m² for Saudi Arabia) a = Solar radiation factor of the sheets (= 0.40 for Zamil Steel standard roof sheeting) e = Proportion of "a" transmitted into the building. This factor is dependent on the "U" value of insulation = 0.093 for a building with insulation = 1.000 for a building without insulation Calculate the ventilation rate required (VRreq'd):

VR req'd =

H S H xDxT

= Specific Heat Capacity of Air = 1.005 where, SH D = Density of Air = 1.206 kg/m3 T = Temperature difference (use °C difference per meter of stack height). Determine the quantity of ventilators needed, Quantity of ventilators =

VRreq© d capacity in m3/s of all ventilators R

where, R = Exhaust

Calculate the total area of gravity ventilators: Total ventilator area =

VR req'd 1

[0.03 x Stack height x T ]2

For special ventilators, the supplier's catalogue must be consulted.

DM 03.10.00

12-12

ZAMIL STEEL BUILDINGS DESIGN MANUAL 12. Miscellaneous services

PEB DIVISION

Example of Ventilation Design using the Air Change Method A Clear Span (CS) building that is used as a factory requires ventilation using gravity ridge ventilators. The building is 140 m long and 36 m wide. The eave height is 9m. The roof has a 0.5/10 slope. The temperature difference between the inside and outside of the building is not expected to exceed 10oC. Determine the number and size of gravity ventilators that are needed.

i) Stack height

= 9.45 m.

ii) R (for ZRV 300) =1.276 m3/s R (for ZRV 600)=2.551 m3/s

Exhaust capacity (R), at 9.45m stack height, is determined by interpolation The recommended number of air changes per hour (N) for factories is 5 to 10 times.

iii) N = 8 iv) V = 140 x 96 x 9.45 = 47,628 m3 v)

The average of the eave height and the ridge height.

QV =

47628 x10 = 82 . 95 1.276x3600

Volume of building.

Quantity of ZRV 300 ventilators required. Need 83 (ZRV 300) ridge ventilators. The maximum number of ridge ventilators (Qmax) that the building can accommodate.

vi)

Q max =

140 = 46 .67 3

vii) Qmax = 46 ventilators < Qv = 83 47628 x10

viii) Q V = 2.551x3600

= 41 . 49

Q max =

Building length (m) Ventilator lenght (m)

ZRV 300 cannot be used. Try ZRV 600 Quantity of ZRV 600 ventilators required. Qv < Qmax = 46

Use 42 gravity ridge ventilators (ZRV 600) for the building.

DM 03.10.00

12-13

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

12. Miscellaneous services

12.4. FOOTING There are two types of footing design normally adopted for footings supporting the pre-engineered building columns.

i) ii)

Spread footing without hairpin Spread footing with hairpin

Spread footing with hairpin (tie-rod cast in slab) is adopted when ground slab is used that enables the horizontal loads to be structurally transmitted into the slab and dissipated into the subsurface soil by means of frictional forces between the ground slab and the soil beneath it. This technique requires the provision of horizontal V-shaped reinforcing bars (called hairpins) anchored around the anchor bolts and protruding into the slab. Spread footings with hairpin are always designed as pin-based footings where hairpin is designed to resists horizontal load and footing is designed only for vertical loading. Since there will be no pier, horizontal loads do not impose any moment on the footing. Spread footing without hairpin have pier (pedestal) and the footing is designed for vertical, horizontal and moment that is imposed by the horizontal loads. Moment = Horizontal Force x Height of Pier In the presence of moment reaction for fixed based columns, the total moment is calculated as: Moment = Moment + Horizontal Force x Height of Pier

DM 03.10.00

12-14

ZAMIL STEEL BUILDINGS DESIGN MANUAL 12. Miscellaneous services

PEB DIVISION

12.4.1. Spread Footings with hairpin Spread footing with hairpin consists of thickened slab with welded wire mesh, tie rod cast in the slab termed as hairpin and an isolated footing cast monolithically with slab. The procedure for designing the thickened slab footing with hairpin is as follows: i) Get column load from reaction tables and add an estimated weight of the footing and overburden to obtain the total vertical load, P. ii) Obtain the allowable soil pressure, qall, from the soil test performed at the actual job site. This value should be supplied to Zamil Steel prior to the foundation design. In the absence of this information, the design engineer shall clearly state the design assumption made and ask for client verification in the design calculations.

iii) Calculate the required footing area, Af:

Af =

P q all

Select footing dimensions to give the required footing area. Normally, a square footing is adopted unless some limitation exists which would limit the size of the footing in one direction. In such a case, rectangular footing would be used. Note: The column must be located in the center of the footing for the above procedure. Otherwise, eccentricity must be considered.

DM 03.10.00

12-15

ZAMIL STEEL BUILDINGS DESIGN MANUAL 12. Miscellaneous services

PEB DIVISION

iv) Using Factored Loads:

• • • •

Determine the footing thickness required for punching and beam shear. Check the footing thickness for bending. Design the hairpin or tie rods to resist the lateral loads Prepare a design sketch.

The following example illustrates the procedures as outlined above for designing a thickened slab footing. Example Design thickened slab footing for the standard rigid frame using the following data: qall = 0 .0072kN/cm2 ; fc = 2.068kN/cm2; fy = 41.37kN/cm2. Column loads (from frame analysis output): PD = 12.2kN + footing weight + overburden PL = 54kKN HD = 4.93kKN HL = 21.8kN Puplift = 23kN Hbracing = 16.71kN Base plate size: 220 mm x 240 mm x l2 mm with (2) – M30 anchor bolts. Assume footing weight = 25kN PD = 12.2 + 25 = 37.2kN Note: For most thickened slabs, overburden does not exist. Calculate required footing area, Af

Af =

37.2 + 54 = 12667cm 2 0.0072

B = √Af = √12667 = 112.55 cm Use 120 cm x 120 cm footing

q act =

DM 03.10.00

91.2 = 0.0063kN/cm 2 < 0.0072kN/cm 2 OK 120 x120

12-16

ZAMIL STEEL BUILDINGS DESIGN MANUAL 12. Miscellaneous services

PEB DIVISION

Determine footing thickness a) Punching shear (two-way shear) Pu = 1.4 PD + 1.7 PL = 1.4 x 37.2 + 1.7 x 54 = 143.9kN

q ult =

Pu q act P

q ult =

143.9x0.00 63 = 0.0099 kN/cm 2 91.2

Effective depth, d (=thickness-concrete cover) is obtained using following quadratic equation. d2 (vc + qult/4) + d (vc + qult/2) w = [BL - w]2 qult/4 ------------- 1 where: vc = φ(0.0525 + 0.105 / β c ) √fc < 0.105 φ √fc where β c = w/x (w and x are the longer and shorter base plate dimensions respectively

β c = 240/220 = 1.09 > 2.0 use β c = 2.0 vc = 0.85 x 0.105 √2.068 = 0.1284kN/cm2 Using these values in equation 1 0.1309 d2 + 2.934 d - 34.442 = 0 Solving this quadratic equation: ⇒ d = 8.409cm Use Tmin = 30.0cm dmin = 30.0 - 7.5 - 1.0 = 21.5cm b) Beam shear Vu < φVn Vu < φ 0.0525 √fc bwd Vu = qult [(L - w)/2 - d] L = 0.0099 [(120.0 - 22.0)/2 - 21.5] x120.0 = 32.67kN < 0.85 (0.0525) = 32.67kN < 165.6kN --OK

( 2.068) (120.0) (21.5)

d = 21.5cm is adequate DM 03.10.00

12-17

ZAMIL STEEL BUILDINGS DESIGN MANUAL 12. Miscellaneous services

PEB DIVISION

Design the footing for moment:

M max =

M max =

(q ult x B)z 2

0.0099x 120x 492 = 1426kN - cm 2

Calculate As:

Ru =

ρ=

Mu

φbd

2

=

1426 = 0.029kN/cm 2 2 0.9x120x21.5

0.85f c′  2R u  1 − 1 −  f y  0.85f c′ 

⇒ ρ = 0.0007

ρmax = 0.75 ρb = 0.0214 > 0.0007 ρmin = 0.0018 when fy = 34.5kN/cm2 0.0020 when fy = 41.37kN/cm2 Use ρ = ρmin = 0.0020 As = ρbd = (0.0020) (120) (21.5) = 5.16cm2 Using 12 mm bars: Spacing

=

L (Abar)/As = 120x1.13/5.16 = 26.3cm

Therefore use 12mm φ bars at 25cm.

DM 03.10.00

12-18

ZAMIL STEEL BUILDINGS DESIGN MANUAL 12. Miscellaneous services

PEB DIVISION

Design the spread tie (hairpin) to resist later loads

ΣFy = 0 ⇒ H - 2T sin 60o = 0

T=

H 4.93 + 21.8 = = 15.44kN 0 2sin60 2sin60 0

Asteel = 0.6Fy ⇒ db = 0.89cm Use 12mm φ bar

To adequately resist the horizontal thrusts, the spread tie rod must extend into the slab a sufficient distance so that the length of the "failure tensile crack" will have enough reinforcing mesh crossing it - such that a proper factor of safety is developed. If the angle of the crack from the end of the ties is 45 degrees to the edge of the slab, and if the bolt gauge is assumed as zero (conservatively), then the projected length of the tensile crack is: = 2 (0.5) Lt + 2 (0.866) Lt = Lt + 1.732 Lt = 2.732 Lt

Lc

Assume the slab reinforcement is 150 x 150 - 4/4 ⇒

AS = 0.838 cm2/m

Assume the allowable stress for the mesh 13.79kN/cm2, the total tensile force resisting the opening of the tensile crack, Lc, is Ft

= (0.838) (13.79) (2.732 Lt) = 31.562 Lt kN/m

Ft = H 31.562Lt = 26.73

DM 03.10.00

12-19

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

12. Miscellaneous services

Lt = 26.73 / 31.562 = 0.847m Total Length = 2 Lt + bolt gauge = 2 x 0.847 + 0.10 = 1.8 m, say 2.0 Use 12mm φ hairpin. 2.0 meter long. Design Sketch

DM 03.10.00

12-20

ZAMIL STEEL BUILDINGS DESIGN MANUAL 12. Miscellaneous services

PEB DIVISION

Design of Slab The design of a concrete slab on ground must be carried by a qualified Foundation Engineer. The following table is provided only for guidance. The capacity of the slab depends on the thickness and quality of concrete, the reinforcement and the type of composition of the soil.

Type

Minimum

Reinforcement

Slab

No.

Thickness

Of

(kN/m2)

(mm)

Layers

-

50

None

Residential or Light Commercial

(23.74) (6) L > 142.43cm, say 180 cm If L =180 cm, then using equation, 3

Af =

129.83  6 x23.74  = 31230cm 2 1+   0.0072  180 

B = Af /L = 3230 /180 = 179.45 cm ⇒ Use 180cm The maximum soil pressure (qmax) can be calculated from the following equations:

q max = q min =

129.83  6 x23.74  1+ = 0.0072kN/cm 2   180x180  180 

129.83  6 x23.74  1− = 0.0008kN/cm 2   180  180x180 

qmax = 0.0072 KN/cm2 < 0.0072kN/cm2 ---OK

DM 03.10.00

12-26

ZAMIL STEEL BUILDINGS DESIGN MANUAL 12. Miscellaneous services

PEB DIVISION

Since this is a square footing, the soil bearing in the other direction need not be checked because Hbracing < HD + HL Use B = L = 180cm. Ultimate Pressure qult Pu

=

1.4 (PD) + 1.7 (PL) = 1.4 (75.83) + 1.7 (54) = 198.0kN

qult-max =

Pu x qmax / P = 198 x 0.0072 /129.8 = 0.011kN/cm2

qult-min =

Pu x qmin / P = 198 x 0.0008 /129.8 = 0.0012kN/cm2

Soil pressure diagram:

Footing Thickness Punching Shear Assume 35cm x 35cm pier Critical section for punching shear is shown in the sketch, which is at a distance of d/2 from the face of pier. Note:

As a general rule, the footing thickness, t, is about one-fifth of the larger footing dimension. A minimum thickness of 300 mm should be used.

DM 03.10.00

12-27

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

12. Miscellaneous services

Effective depth, d (=thickness-concrete cover) is obtained using following quadratic equation. d2 (vc + qavg/4) + d (vc + qavg/2) w = [BL - w]2 qavg/4 where: vc = φ(0.0525 + 0.105 / β c ) √fc < 0.105 φ √fc where β c = w/x = 1 (For a square pier w = x) > 2.0 use β c = 2.0 vc = 0.85 x 0.105 √2.068 = 0.1284kN/cm2 Using these values in quadratic equation 0.1298 d2 + 4.6 d – 47.54 = 0 Solving the quadratic equation: d = 8.36cm Use Tmin = 30.0cm dmin = 30.0 - 7.5 - 1.0 = 21.5cm Check actual punching shear

Vu-actual = qavg[BL-(w+d)(x+d)] = 0.0061 [180x180-(35+21.5)2]= 178.17kN Vu-allow = 0.105 φ √fcbod where, bo = 2 (w+d) + 2 (x+d) = 2 x 2 x (35+21.5) = 226cm Vu-allow = 0.105 x 0.85√2.068 x 226 x 21.5 = 623kN > 178.17kN --OK Beam shear Vu-allow = φ 0.0525 √fc Bd = 0.85 x 0.0525 x √2.068 x 180x21.5= 248.4kN Vu-actual = 0.5(qcrit+qmax) [0.5(L - w) - d] B where, qcrit = qmin+qs[L-(z-d)]=0.0012+0.00005[180-(72.5-21.5)]=0.00765kN/cm2 Vu-actual = 0.5(0.00765+0.011)[0.5(180 – 35) – 21.5] 180 = 85.6kN < 248.4kN --OK d = 21.5cm is adequate

DM 03.10.00

12-28

ZAMIL STEEL BUILDINGS DESIGN MANUAL 12. Miscellaneous services

PEB DIVISION

Design the footing for moment: Critical section for bending moment is right at the face of pier at a distance z from the right edge of footing.

qcrit = qz = qmin+qs[Lz]=0.0012+0.000054[180-72.5]=0.007kN/cm2 Mmax= [0.5 qz z2 + (qmax-qz)z2/3]B Mmax= [0.5x0.007x72.52 + (0.011-0.007)72.52 /3]180 = 4573kN-cm

Calculate As:

Ru =

ρ=

Mu

φbd

2

=

0.85f c′ fy

4573 = 0.061kN/cm 2 2 0.9x180x21.5

 2R u  1 − 1 −  0.85f c′  

⇒ ρ = 0.0015

ρmax = 0.75 ρb = 0.0214 > 0.0007 ρmin = 0.0018 when fy = 34.5kN/cm2 0.0020 when fy = 41.37kN/cm2 Use ρ = ρmin = 0.0020 As = ρbd = (0.0020) (180) (21.5) = 7.74cm2 Using 12 mm bars: Spacing = L (Abar)/As = 120x1.13/7.74 = 26.28cm Therefore use 12mm φ bars at 25cm both ways Check development length:

Ld =

0.6A b f y f c′

x 0.8 =

0.6x1.13x41.37x0.8 2.068

= 15.61cm

Available length = z-cover = 72.5-7.5=65cm > 15.61cm --OK DM 03.10.00

12-29

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

12. Miscellaneous services

Pier Design PD HD PL HL MD

= 12.22kN = 4.93kN = 54.0kN = 21.8kN = HD x arm = 4.93kN x 85.0 cm = 1853kN.cm

Apply overload factors and compute the eccentricity Mu = 1.4 MD + 1.7 ML = 1.4 (419.05) + 1.7 (1853) = 3736.77cm Pu = 1.4 PD + 1.7 PL = 1.4 (12.22) + 1.7 (54) = 108.91kN

e

= Mu/Pu = 3736.77/108.91 = 34.31cm

emin = 1.52 + 0.03 h = 1.52 + 0.03 (35) = 2.57 cm < 34.31 cm Use eccentricity, e = 34.31 cm Assume 35 cm x 35cm pier: Agross = 1225cm2 Check slenderness ratio: If KL/r < 22 ---- (for M1 = M2) then the column is classified as a short column and the P∆ effect can be ignored) KL/r = 1x85/(0.3x35) = 8.1 < 22 therefore short column Now proceed as for designing a short reinforced concrete column. Refer to the “Ultimate Strength Design Handbook” (Volume 2), Uniaxial Chart # 9. Compute e/h, g, K e/h = 34.31/35 = 0.98 g = (h – cover)/h = (35 – 2x7.0)/35 = 0.6

K=

Pu 108.91 = = 0.043 f c′ bh 2.068x35x35

K(e/h) = (0.043) (0.98) = 0.042 For fc = 3ksi; fy = 60ksi and g = 0.60 enter the chart with K(e/h) = 0.042 and e/h = 0.98 ⇒ ρg = 0.003

DM 03.10.00

12-30

ZAMIL STEEL BUILDINGS DESIGN MANUAL 12. Miscellaneous services

PEB DIVISION

ρg-min = 0.01 and ρg-max = 0.08 Using ρg = ρg-min = 0.01 Ast = 0.01 (35) (35) = 12.25 cm2 Use (8) - 16mm bars (Ast used = 16.09 cm2>12.25cm2 --OK Lateral tie spacing: Spacing < 16db = 16x1.6 = 25.6 cm < 48 ds = 48x0.90 = 43.2 cm = 35 cm 108.91kN Bearing strength on footing concrete: A1 = bxh = 35 x 35 = 1225 cm2 A2 = (w +4d)2 = 14641 cm2

√A2/A1=3.46 < 2.0 ⇒ Use 2.0 Therefore Pnb = 2 [(0.7) (0.85 fc A1)] = 2[0.70 (0.85 x 2.068 x 1225)] = 3014kN > 108.91kN Dowel bars are required between column and footing even though bearing strength on column and footing is adequate to transfer the factored loading. A Minimum area of reinforcement is required across the interface: As-min = 0.005 (b x h) but not < 4 bars = 0.005 (35 x 35) = 6.125 cm2 < 16.09 cm2 (As provided) Check development length as per ACI 12-3: The formula translated in metric unit is:

Ld =

0.762f y d b f c′

=

0.762x41.37x1.6 = 35.07cm 2.068

Ld shall not be less than 0.435 dbfy = 0.435x1.6x41.37 = 28.79cm The dowel bars must extend at least 35.07 cm into the footing and the pier. Also the number of dowel bars shall equal the number of vertical bars in the pier.

DM 03.10.00

12-31

ZAMIL STEEL BUILDINGS DESIGN MANUAL PEB DIVISION

12. Miscellaneous services

Design Sketch

DM 03.10.00

12-32

ZAMIL STEEL BUILDINGS DESIGN MANUAL 12. Miscellaneous services

PEB DIVISION

When a ground slab is not used as part of the foundation sub-structure, hair pins cannot be used and footings have to be designed to resist both vertical and horizontal loads. For this condition the following table provides guidelines for determining footing size and steel reinforcement.

Design Table for Spread footing without hair pins Column Reactions

Footing Size

Footing Reinforcement

Vertical

Horizontal

Length

Width

Depth

Bottom Steel

Top Steel

kN

kN

(cm)

(cm)

(cm)

Longitudinal

Transversal

Longitudinal

Transversal

30

15

150

150

35

6 Nos. 16 mm Ø

6 Nos. 16 mm Ø

6 Nos. 12 mm Ø

6 Nos. 12 mm Ø

45

20

180

180

35

6 Nos. 16 mm Ø

6 Nos. 16 mm Ø

6 Nos. 12 mm Ø

6 Nos. 12 mm Ø

60

60

260

180

50

7 Nos. 20 mm Ø

9 Nos. 20 mm Ø

7 Nos. 12 mm Ø

9 Nos. 12 mm Ø

75

80

300

210

50

8 Nos. 20 mm Ø

10 Nos. 20 mm Ø

8 Nos. 12 mm Ø

10 Nos. 12 mm Ø

90

100

320

210

50

8 Nos. 20 mm Ø

11 Nos. 20 mm Ø

8 Nos. 12 mm Ø

11 Nos. 12 mm Ø

105

160

360

280

50

10 Nos. 20 mm Ø

13 Nos. 20 mm Ø 13 Nos. 12 mm Ø

13 Nos. 12 mm Ø

The above table is based on the following assumptions: 1. Reinforcing bars are made of Grade 60 / deformed (60,000 psi tensile strength or 42 kg/mm²) steel. 2. Concrete compressive strength is 210 kg/cm² 3. Soil bearing capacity = 1.0 kg/cm²

DM 03.10.00

12-33

View more...