Winfiol Command
September 20, 2017 | Author: errorneous_syntax | Category: N/A
Short Description
Download Winfiol Command...
Description
COMMAND 2G IN WION FIOL Check all alarm in the node Check Critical alarms Check major alarms Check Minor alarms Check External alarms Check Internal alarms Check TG number of specific cell Print MOs for cell Check if the site is Up(CONFIG)/Down(BLOCK) Check this TRX in which sector Total site in one BSC Total site down in one BSC Alarm in one BSC Check RBLT status function or Not Manage info object fault Check ARFCN & BCCH Check Device Check Time Slot Check load software Check perangkat RBLT Cell Name Display RBLT from the site ID Check Equipment Check E1 Status (Working or ABL) Check Quality E1(bit slave) Check ABIS status
allip; allip:acl=a1; allip:acl=a2; allip:acl=a3; allip:alcat=ext; rxasp:moty=rxotg-TG; rxtcp:moty=rxotg,cell=’SiteID’a; rxmsp:mo=rxotg-TG,subord; rxcdp:mo=rxotg-TG; rxmop:mo=rxotrx-TG#-TRX#; rxmfp:moty=rxocf; rxasp:moty=rxocf; allip:alcat=bts; dtstp:dip=all; rxmfp:mo=rxocf-TG; rxcdp:mo=rxotg-TG; rxmdp:dev= rblt-TG,moty=rxots; rxmsp:mo=rxotg-TG,subord; rxmop:mo=rxotg-TG; rxmdp:mo=rxotgrx-TG-0&-1&&-11; rxtcp:mo=rxotg-TG; rxtcp:moty=rxotg,cell=’siteID’a rxapp:mo=rxotg-TG; dtstp:dip=TGrblt; dtqup:dip=TGrblt; rxapp:dip=rxotg-TG;
LOCK , RESTART, UNLOCK Block site from TG Remove site our fo service Put the site in service again Unblock site from TG Lock per TRX Unlock per TRX Lock – TS Unlock – TS Lock – Several TS Unlock – Several TS
rxbli:mo=rxotg-TG,subord,force; rxese:mo=rxotg-TG,subord; rxesi:mo=rxotg-TG,subord; rxble:mo=rxotg-TG,subord; rxbli:mo=rxotrx-TG-TRX,subord,force; rxble:mo=rxotrx-TG-TRX,subord; rxbli:mo=rxots-TG-TRX-TS,force; rxble:mo=rxots-TG-TRX-TS; rxbli:mo=rxots-TG-TRX-TS(0&&-7),subord; rxble:mo=rxots-TG-TRX-TS(0&&-7);
LOADING Rxesi:mo=rxotg-TG,subord; Rxble:mo=rxotg-TG,subord;
RELOADING Rxbli:mo=rxotg-TG,subord,force; Rxese:mo=rxotg-TG,subord; Rxesi:mo=rxotg-TG,subord; Rxble:mo=rxotg-TG,subord; HALTED & UNHALTED CELL Halted Cell Unhalted Cell check status site
rlstc:cell=’SiteIDa,b,c’,state=halted; rlstc:cell=’SiteIDa,b,c’,state=active rlstp:cell=’SiteIDa,b,c’
CHECK ROUTE STATUS Check route status Check route device, ,status block Print all route device Out of service In service De-block the device Find SNT name, MISC1=CIC Check the status of SNT=E1
strsp:r= ; strdp:r= ,state=bloc; blodi:dev= ; exdae:dev= ; exdai:dev= ; blode:dev= ; exdep:dev= ; ntstp:snt=RTDMA-1017;
MOST ‘rl***’ COMMANDS Check cell resources (sectoral busy or idle) Check cell frequency Check GPRS state Print cell info Print cell frequencies Print cell hopping
rlcrp:cell=’SiteIDa,b,c’; rlcfp:cell=’SiteIDa.b.c’; rlgsp:cell=’SiteIDa,b,c’; rlmbp:id=all; rlcfp:cell= ‘SiteIDa.b.c’; rlchp:cell=’SiteIDa,b,c’;
CHANGE BCCH FOR A GIVEN SITE Check the old BCCH Halt the cell Active the cell Change the BCCH Check the measurement frequencies Change the measurement frequency for the idle list only Delete the old BCCH from the idle list only Check the Neigboring sites Check measurement frequency for each neighbour site
rldep:cell=’SiteIDa,b,c’; rlstc:cell=’SiteIDa,b,c’,state=halted; rlstc:cell=’SiteIDa,b,c’,state=active; rldec:cell=’SiteIDa,b,c’,BCCHNO=75; rlmfp:cell=’SiteIDa,b,c’; rlmfc:cell=’SiteIDa,b,c’,LISTTYPE=idle,MBCCHNO=75; rlmfe:cell=’SiteIDa,b,c’,LISTTYPE=idle,MBCCHNO=72; rlnrp:cell=’SiteIDa,b,c’,cellr=all,nodata; rlmfp:cell= ‘SiteIDa,b,c;
ADD NEW BCCH FOR IDLE AND ACTIVE LIST FOR EACH NEIGHBOR SITE rlmfc:cell=’SiteIDa,b,c’,LISTTYPE=iddle,MBCCHNO=75; rlmfc:cell=’SiteIDa,b,c’,LISTTYPE=active,MBCCHNO=75; Check measurement frequency for each neighbour site rlmfp:cell=’SiteIDa,b,c’; Couble check that the cell is active rlstp:cell=’SiteIDa,b,c’; Change SPDCH RLGSC:cell= ‘SiteIDa,b,c’,spdch= ;
Check SW restart time syrip:sdt; Check processor load plldp: Check for software error syrip:survey; Take Log before doing this command, it will print and cease the alarm Cease MT failed authentication alarm in MSC mgaar; Cease Sizure supervision alarm setar; Cease Sizure Quality supervision alarm segar:r= ;
syrip:event= ;
CHECK RP AND EM exrpp:rp= ; exemp:rp= ,em=all; CONTINUITY CHECK FAILURE Check route device Check route state Print the device failed first continuity Re-check for route Print device state Block the device Remove the device from the service Put the device again in-service De-block the device
strdp:r= ; strsp:r= ; tccfp:r= ; stdep:dev= ; blodi:dev= ; exdae:dev= ; exdai:dev= ; blode:dev= ;
DEFINE A CELL IN MSC OR MSS Print all cell defined in MSC Define new cell in MSC
mgcep:cell= ; MGCEI:CELL= ,CGI= ,BSC= ;
TRANSMISSION REMOTE BSC (RTLT) Check status E1 remote bsc Check quality E1 remote bsc
dtstp:dip=002rtlt; dtqup:dip=002rtlt;
HINT To search for all rl*** command in ALEX just write rl*** To search for all rx*** command in ALEX just write rx***
View more...
Comments