Ventilacion de La Mina Raura
December 10, 2018 | Author: Royer Emerson Cahuana | Category: N/A
Short Description
Download Ventilacion de La Mina Raura...
Description
UNIVERSIDAD UNIVERSIDAD NACIONAL DE PIURA
FACULT ACULTAD DE INGENIERIA INGENI ERIA DE MINAS M INAS TEMA
:
INTEGRANTES
:
VENTILACION DE LA MINA RAURA Zambrano Hurtado Gloria Ramos García Jose Luis López Ramírez Juan Carlos Merino Carhuachinchay Jhermain Ojeda Carrión Keber
PROFESOR
: ING. JOSE CHANG VALDIVIEZO.
MINA RAURA: UBICACION
MINA RAURA: UBICACION
UBICACIÓN Y ACCESO UBICACION: Raura
Oyón
Cerro de Pasco Distrito: San Miguel de Cauri
Provincia: Lauricocha
Lima
La Oroya
Dpto: Huánuco ALTITUD: 4,700 m.s.n.m. ACCESO: 1- Huacho-Sayán-Oyón-Raura Huacho-Sayán-Oyón-Raura 2- Huánuco-Jesús-Cauri-Raura 3- Pasco-Oyón-Raura
CÍA. MINERA RAURA S.A. RECIBIÓ EN DICIEMBRE DEL 2005 LA CERTIFICACIÓN INTERNACIONAL EN ISO14001 (AUDITORA INTERNACIONAL BUREAU VERITAS) LA AUDITORIA INTERNACIONAL DE OHSAS SE REALIZARA EN EL MES DE OCTUBRE DEL 2006 SE ASEGURA QUE NUESTROS PROCESOS Y NUESTRAS OPERACIONES CUMPLEN CON LOS ESTÁNDARES INTERNACIONALES DE SEGURIDAD Y CALIDAD AMBIENTAL
INTRODUCCION LA UNIDAD MINERA RAURA, DE PROPIEDAD DE LA CÍA. MINERA RAURA S.A. INICIÓ SUS OPERACIONES EN 1960. ESTAS OPERACIONES SE EJECUTARON MEDIANTE LABORES SUBTERRÁNEAS CON PRODUCCIÓN DE MINERAL POLIMETÁLICO ACTUALMENTE, CÍA. MINERA RAURA S.A., ES UNA EMPRESA PERUANA DE LA MEDIANA MINERÍA, DEDICADA A LAS ACTIVIDADES MINERO METALÚRGICAS DE EXPLOTACIÓN, BENEFICIO Y COMERCIALIZACIÓN DE CONCENTRADOS DE MINERALES POLIMETÁLICOS (ZINC, PLATA, COBRE Y PLOMO).
LOS MÉTODOS DE EXPLOTACIÓN SON: SHIRINKAGE, CORTE Y RELLENO ASCENDENTE (BREASTING Y TALADROS INCLINADOS), CÁMARAS Y PILARES, BLOCK CAVING (TALADROS LARGOS). COMPAÑÍA MINERA RAURA S.A. BUSCA DESARROLLAR UN SISTEMA DE VENTILACIÓN ÓPTIMO QUE BRINDE UN AMBIENTE SEGURO , SALUDABLE Y CÓMODO AL PERSONAL EN INTERIOR MINA COMPAÑÍA MINERA RAURA S.A. BUSCA LOGRAR AHORROS EN SUS COSTOS DE OPERACIÓN REFERENTE A VENTILACIÓN EN UNA MINA COMO RAURA NO SE PUEDE LOGRAR BUENOS RESULTADOS EN VENTILACIÓN SINO SE CUENTA CON LOS EQUIPOS Y LA INFRAESTRUCTURA ADECUADOS, EL DIRECCIONAMIENTO Y VOLUMEN DE AIRE REQUERIDO SE DEBE LOGRAR CON AYUDA DE VENTILACIÓN MECÁNICA
PLANO ISOMETICO - RAURA
CIRCUITO DE VENTILACION PRIMARIO
INGRESO DE AIRE A CATUVA Nv 300 (SHUCSHAPAJ) INGRESA AIRE Nv 380 (TINQUICOCHA) INGRESA AIRE Nv 590 (HIDRO) INGRESA AIRE Nv 630 (CATUVA) INGRESA AIRE Nv 700 (CATUVA) INGRESA AIRE
CIRCUITO PRIMARIO CATUVA
CIRCUITO DE VENTILACION PRIMARIO
SALIDA DE AIRE CATUVA Nv 630, RB 66 Nv 630, RB 69 Nv 630, RB 70 Nv 630, RB 02 Nv 630, RB 23 Nv 630, RB 10 Nv 700, RB 09
BALANCE DE AIRE PARA MINA CATUVA NECESIDADES DE AIRE PARA CATUVA POR LA CANTIDAD DE HOMBRES POR GUARDIA 148 hombres x 6.0 m3/min 888.00 m3/min POR EL USO DE EQUIPO DIESEL 1681.50 HP x 3.0 m3/HP/min 5,044.50 m3/min POR EL USO DE EXPLOSIVOS 25.0 m/min x 8 Nv x 11.11 m2 2,222.00 m3/min TOTAL
8,154.50 m3/min 287,972.90 CFM
BALANCE DE AIRE PARA MINA CATUVA INGRESO DE AIRE ( ANTES ) LUGAR DE INGRESO Nv 300, Cx 575
m3/min
CFM
1,534.91
54,204.73
Nv 380, Cr 080 SW Nv 380
594.45 199.32
20,992.78 7,038.91
Nv 590, Cr 070 SW Nv 590 RB
528.96 140.99
18,680.01 4,979.00
86.14
3,041.99
2,062.54 114.94 5,262.25
72,837.77 4,059.06 185,834.25
Nv 590, Gl 480 Nv 630, Cx 230 SW Nv 700 TOTAL
BALANCE DE AIRE PARA MINA CATUVA INGRESO DE AIRE ( DESPUES ) LUGAR DE INGRESO Nv 300, Cx 575
m3/min
CFM
2,944.75
104,000.50
Nv 380, Cr 080 SW Nv 380
594.45 199.32
20,992.78 7,038.91
Nv 590, Cr 070 SW Nv 590 RB
1,529.11 140.99
54,000.00 4,979.00
86.14
3,041.99
3123.35 114.94 8,733.27
110,300.00 4,059.06 308,412.24
Nv 590, Gl 480 Nv 630, Cx 230 SW Nv 700 TOTAL
RESUMEN BALANCE DE AIRE CIRCUITO PRINCIPAL CATUVA INGRESO DE AIRE CFM
185,834.25
308,412.24
NECESIDAD DE AIRE CFM
287,972.90
287,972.90
COBERTURA
OBSERVACION
%
64.50
107.10
ANTES DE INSTALAR VENTILADORES DESPUES DE LA INSTALACION DE VENTILADORES
- LAS CORRECCIONES HECHAS AL CIRCUITO PRINCIPAL:
INCREMENTO DE CAUDAL DE AIRE DE 185,834.25 CFM A 308,412.24 CFM - SE LOGRO INSTALANDO 02 VENTILADORES DE 100,000 CFM Y
01 VENTILADOR DE 50,000 CFM, ASÍ COMO EL MEJORAMIENTO DE PUERTAS Y TAPONES DE VENTILACION - CON ESTA CORRECCION EL SISTEMA DE VENTILACION
CUMPLE CON LA NECESIDAD DE AIRE REQUERIDO EN MINA CATUVA
PUERTA DE VENTILACION
VENTILACION SECUNDARIA
- PARA LOS CIRCUITOS SECUNDARIOS, LUEGO DE LA
EVALUACION SE DETERMINO COMPLETAR LAS PREPARACIONES EN LAS LABORES DE EXPLOTACION - LA CONSTRUCCION DE DUCTOS METALICOS PARA ELIMINAR
CAIDAS DE PRESION EN LOS CODOS - EL USO DE MANGAS DE VENTILACION CON LOS DIAMETROS
APROPIADOS - PARA LABORES MAYORES A 60.0 m DE LONGITUD SE
INSTALAN VENTILADORES EN SERIE GENERALMENTE CADA 100.0 m (DEPENDIENDO DE LA CAPACIDAD DEL VENTILADOR)
VENTILADOR SECUNDARIO
DISTRIBUCION Y COSTO DE VENTILACION ANTERIOR VENTILADOR
MOTOR
FACTOR
CAPACIDAD
(Kw)
(horas)
(CFM)
Kw-h
$/Kw-hora
$/dia
$/año
UBICACIÓN
VMR-12
75.00
1.0
50,000
1800.00
0.045
81.00
29160.00
VMR-13
11.25
1.0
8,000
270.00
0.045
12.15
4374.00
VMR-14
95.25
0.8
50,000
1714.50
0.045
77.15
27774.90 Nv 300,Cx 035
VMR-11
22.50
1.0
20,000
540.00
0.045
24.30
8748.00 Nv 340, Rp 895
VMR-10
24.00
1.0
20,000
576.00
0.045
25.92
9331.20 Nv 380, Cx 100
VMR-09
11.25
1.0
15,000
270.00
0.045
12.15
4374.00
VMR-05
37.50
0.8
18,000
675.00
0.045
30.38
VMR-06
15.00
0.8
15,000
270.00
0.045
12.15
4374.00
Nv 490, Cx 943
VMR-08
15.00
1.0
15,000
360.00
0.045
16.20
5832.00
Nv 490
VMR-03
41.25
0.8
20,000
742.50
0.045
33.41
12028.50
VMR-04
34.50
0.8
20,000
621.00
0.045
27.95
10060.20 Nv 540, Tj 082
VMR-01
191.25
1.0
120,000
4590.00
0.045
206.5
74358.00
Nv 630
VMR-02
150.00
1.0
100,000
3600.00
0.045
162.0
58320.00
Nv 630
VMR-15
24.00
0.8
15,000
432.00
0.045
19.44
6998.40
VMR-16
24.00
0.8
20,000
432.00
0.045
19.44
6998.40 Nv 740, Tj 130
VMR-27
40.73
1.0
20,000
977.40
0.045
43.98
15833.88 Nv 440, COBRI
TOTAL
812.48
17870.4
804.1
Nv 300 Nv 300, Tj 835
Nv 380, Cx 315
10935.00 Nv 490, Cx 943
255966.4
Nv 590, Cx 112
Nv 630, Tj 990
DISTRIBUCION Y COSTO DE VENTILACION ACTUAL VENTILADOR
MOTOR
FACTOR
CAPACIDAD
(Kw)
(horas)
(CFM)
Kw-h
$/Kw-hora
$/dia
$/año
UBICACIÓN
VMR-12
75.00
1.0
50,000
1800.00
0.045
81.00
29160.00
VMR-13
11.25
1.0
8,000
270.00
0.045
12.15
4374.00
Nv 300, Tj 835
VMR-09
11.25
1.0
15,000
270.00
0.045
12.15
4374.00
Nv 380, Cx 315
VMR-06
15.00
0.8
15,000
270.00
0.045
12.15
4374.00
Nv 490, Cx 943
VMR-08
15.00
1.0
15,000
360.00
0.045
16.20
5832.00
Nv 490
VMR-03
41.25
0.8
20,000
742.50
0.045
33.41
12028.50
Nv 590, Cx 112
VMR-01
191.25
1.0
120,000
4590.00
0.045
206.55
74358.00
Nv 630
VMR-02
150.00
1.0
100,000
3600.00
0.045
162.00
58320.00
Nv 630
VMR-15
24.00
0.8
15,000
432.00
0.045
19.44
6998.40
TOTAL
534.00
555.05
166284.90
12334.50
Nv 300
Nv 630, Tj 990
VENTAJAS LOGRADAS - SE REDUJO EL NUMERO DE VENTILADORES INSTALADOS DE
16 A 09, CON EL CONSIGUIENTE AHORRO DE ENERGIA - SE DA MAS EFICIENCIA A LAS OPERACIONES DEBIDO A QUE
LOS TIEMPOS PARA VENTILACION SON MENORES - DEBIDO A QUE SE CONSTRUYERON CHIMENEAS DE
VENTILACION EN LAS LABORES SE HACE POSIBLE EL USO DE ANFO - EL AHORRO EN VENTILACION CALCULADO SOLO PARA
CATUVA ES: 89,681.58 US$/AÑO
VENTILACION SECUNDARIA
RB-83 Y RB 79 NV 540 A 300 B BALILLA NV-540 NV-490 RB-83 RB-79
NV-380
NV-300
PLANTA RB-83 NV 540 A 300 B. BALILLA NV-300
NV-380 RB-83
NV-540
NV-490
SECCION RB-83 NV 540 A 300 B BALILLA NV-540
NV-490
RB-83 CUERPO DE MINERAL LONGITUD =238.00 MTS INCLINACION =-79°
SUBNIVEL NV-380
NV-300
VENTILACION SECUNDARIA
VENTILACION SECUNDARIA
CALIDAD DEL AIRE - UN BUEN SISTEMA DE VENTILACIÓN REQUIERE TAMBIÉN EL
MONITOREO CONSTANTE DE VEHÍCULOS QUE INGRESAN A INTERIOR MINA, QUE LA EMISION DE GASES DE ESTOS VEHICULOS ESTE CONTROLADA
- LA CANTIDAD DE AIRE NO DEBE SER MENOR A 3.0 m3/min
POR CADA HP QUE DESARROLLEN LOS EQUIPOS - LA CALIDAD DEL AIRE ESTA EN FUNCIÓN AL CONTENIDO DE
O2 (MAYOR A 19.5% VOLUMEN)
- PARA EL USO DE ANFO LA VELOCIDAD NO DEBERÁ SER
MENOR A 25 m3/min
- LA EVALUACIÓN DEL CIRCUITO DE VENTILACIÓN SE
REALIZARA EN UN PERIODO MENOR A 06 MESES
CALIDAD DEL AIRE
MONITOREO SEMANAL DE CO
CONCLUSIONES: - EL NUMERO DE PERSONAL EN CATUVA ES: EE OPEMISS SRL : 65 hombres EE MICONG SRL : 55 hombres AESA MINING : 13 hombres OTROS : 15 hombres HACEN UN TOTAL DE 148 hombres, REQUIRIENDO UN TOTAL DE
888.00 m3/min DE AIRE
- EN MINA CATUVA SE TIENEN EN OPERACIÓN EN INTERIOR MINA EN SIMULTANEO DURANTE EL TURNO: SCOOPTRAMS : 06 und C BAJO PERFIL: 02 und CAMIONETAS : 13 und CAMIONES : 06 und VOLQUETES : 08 und EQ SERVICIOS : 02 und HACIENDO UN TOTAL DE 1681.50 HP Y REQUIRIENDO UN CAUDAL DE 5,044.50 m3/min DE AIRE
- EL PROBLE MA DE LA VENTILACION SE AGUDIZA DEBIDO A QUE LAS LABORES SE POLARIZAN - EL CIRCUITO PRIMARIO DE VENTILACION EN CATUVA ESTA DISEÑADO PARA SUMINISTRAR AIRE A CADA LABOR DE LA MINA, PARA ELLO ES NECESARIO ORGANIZAR LA VENTILACION SECUNDARIA - LAS LABORES DEBEN CUMPLIR SUS ETAPAS HASTA QUEDAR APTAS PARA SU EXPLOTACION, UNA BUENA PLANIFICACION DE LABORES AYUDARA A EVITAR FUTUROS PROBLEMAS DE VENTILACION - LAS CHIMENEAS DE VENTILACION QUE SON PARTE DEL CIRCUITO PRINCIPAL DE VENTILACION TAMBIEN PUEDEN SER USADAS COMO CHIMENEAS DE SERVICIOS PARA LINEA ELECTRICA, TUBERIA DE RH. AGUA, AIRE COMPRIMIDO, ETC, Y DEBEN SER INDEPENDIENTES DE LAS LABORES QUE VENTILAN LOS TAJEOS
- EL CIRCUITO PRINCIPAL DE VENTILACION EN CATUVA SE
ALIMENTA DE AIRE LIMPIO POR 05 NIVELES DE LA MINA EL CUAL SE CONDUCE A LAS LABORES EN OPERACIÓN
- 02 NIVELES ALIMENTAN AIRE EN DESCENSO Y 03 NIVELES
ALIMENTAN AIRE ASCENDENTE
- TODO ESTE AIRE SE HACE LLEGAR AL Nv 540 DE LA MINA QUE
SE CONVIERTE EN EL CENTRO DEL SISTEMA DE VENTILACION Y DESDE ALLI SE EXTRAE CON 02 VENTILADORES DE 100,000 CFM A TRAVES DE RBs A SUPERFICIE
-
SE DEBE MANEJAR EL CONCEPTO DE INSTALAR VENTILADORES SECUNDARIOS SOLO EN LABORES DE AVANCE
BIBLIOGRAFIA www.todoexpertos.com www.arqhys.com/ventilacion-minas. www.derenatura.com/elrinconminero www.raura.com
View more...