PowerCommand 3.3 FOR KTA38 HYDRO MECHANICAL GENSET PAGE
TITLE
DESCRIPTION
1
INDEX
COVER PAGE
2
WIRING DIAGRAM
SCHEMATIC, ELECTRICAL CONNECTIONS
3
GENSET LOCATION, GENSET
DEVICE LOCATIONS ON GENSET AND HMI
4
LOCATION DIAGRAM, CONTROLS
DEVICE LOCATIONS IN CONTROL BOX
5
OPTIONS
ACCESSORY CONNECTIONS
6
ADDITIONAL PINOUTS
ADDITIONAL PINOUT CONNECTIONS C
C
Notes: 1.
Fusing requirements for Arc flash protection for TB7 (Bus/Utility Voltage Sense)*: If your potential circuits have available incident energy > 1.2 Cal/cm2 or 5J/cm2 then you need to protect for arc flash in the lines feeding TB7**.
Available Incident energy > 1.2 Cal/cm2 or 5J/cm2 is typically found when any of the the following is true:
2.
A)
LL Voltage > 240Vac OR
B)
Paralleled OR
C)
Alternator size > 125kVA
Fusing requirements for Arc flash protection for TB7 (Bus/Utility Voltage Sense)*: If Available Incident energy is > 1.2 Cal/cm2 or 5J/cm2 then the use of current limiting fuses or other suitable means in the lines feeding J22 and TB7** are needed.
The following suggested current limiting fuses will accomplish this:
B
B
A) Fuse rating: 600Vac, 0.5A, AIC=200kA, fast acting, current limiting, Class CC (e.g. Ferraz Shawmut ATMR ½ or equiv.) B) Use 600Vac rejection type fuse holder with AIC=200kA rating, e.g. Ferraz Shawmut 30323R or equiv. C) Fuses must be placed near the voltage source. * Per NFPA 70E and Cummins Electrical Safety Policy. **Fusing protecting the circuit feeding TB7 must also meet all local code requirements. 3.
For enclosure-container wiring diagrams refer to the following drawings. 0630-2941 0630-3613 0630-3080 0630-2867 0630-2868 0630-2873
A
A
UNLESS OTHERWISE SPECIFIED, ALL DIMENSIONS ARE IN MILLIMETERS
.X ` .XX`
ANG TOL: `
6
5
4
3
HOLE
DIM
X `
0.00- 4.99 +0.15/-0.08 5.00- 9.99 +0.20/-0.10 10.00-17.49 +0.25/-0.13 17.50-24.99 +0.30/-0.13 SCALE :
SIM TO
DWN
DO NOT SCALE PRINT
CKD
N_SCHOTTLER
APVD
M_POZO
DATE
01-04-2011
- CONFIDENTIAL -
PROPERTY OF CUMMINS POWER GENERATION
2
CUMMINS POWER GENERATION
N_SCHOTTLER
FOR INTERPRETATION OF DIMENSIONING AND TOLERANCING, SEE ASME Y14.5M-1994
DIAGRAM, SCHEMATIC
SITE CODE FIRST USED ON
KTA38
PGK
DWG SIZE
D
SHEET
A035H705
1
OF
6
DWG REV
C
1
Drawing Name: A035H706 Revision: C Part Name: A035H705 Revision: C Sheet 1 of 7
VISIO
6
REMOTE E-STOP 1B 1A 2B 2A
JUMPER 1
REMOTE E-STOP
1
2
4
3
4
5
JUMPER 2
3A
3B
4A
4B
D
USER INTERFACE
Sw B+ K7
3300 TB1-16
5 J20-11 Starter Disconnect Input 1B 2B
K10-86
PCC3300
E-STOP B+
BASEBOARD
3B
E-STOP
FUSED B+
2
1
P2-7
5
4
6
1
K16-A P21-9 (AUX 105)
RETURN P25-6
P25-2 P25-11
P29-6 RUN (WAKE-UP)
K10-SP
PCC NET SHLD
TB1-4 SEE SHEET 5 TB1-6 SEE SHEET 5
HARNESS, INTERFACE PCC3300-AUX101: A035E359
FUSED B+,4B
2B
P20-18
3B 4B
P20-19
P1-4 P1-5
BARGRAPH
2B BUS L2
P14-1
PART NUMBERS AUX 101: 0327-1536
REMOTE E-STOP 1B
J4-1
3B BUS L3 4B BUS L4
P1-3 PCC NET A (+)
PART NUMBERS HMI 114: 0300-6366-02
W1 SHIELD
HARNESS, INTERFACE PC TOOL TO PCC3300: A040D379
TB7-2 FUSED B+ - 2B
TB7-4
J4-3
5
J4-4
6
J4-5
P1-5 (AUX 101)
A
P12-3 P12-6
1B
SEE SHEET 5
SEE SHEET 5 P10-3, P11-6
SEE SHEET 5 P11-6 SENSE
P10-9, P11-5
P11-5 RETURN
P10-4, P11-8
P11-8 SENSE
P10-10, P11-7
P11-7 RETURN
SEE SHEET 5
SEE SHEET 5
EXHAUST TEMP RIGHT BANK RTD (E7) E7-A E7-B
EXHAUST TEMP LEFT BANK RTD (E6)
SEE SHEET 5
SEE SHEET 5
E6-A
SEE SHEET 5
SEE SHEET 5
E6-B
SEE SHEET 5
SEE SHEET 5
SEE SHEET 5
SEE SHEET 5
SEE SHEET 5
SEE SHEET 5
LEGEND
SEE SHEET 5
OPTIONAL
MODBUS FACTORY CONNECTIONS
J26-6 N/A
D1
J26-7 FIELD CURRENTJ26-8 B+ RETURN HARNESS, ALTERNATING CURRENT: A034Y614
1
3B
2
4B
3
5B
FAST ON CONNECTOR
J26-9 AVR B+
HARNESS, INTERFACE PCC3300 TO AUX 105: A035G905
SET SCREW TERMINAL
J26-14 FIELD CURRENT+ LOW COOLANT TEMPERATURE (S4)
J26-16 AVR PWM+
PLUG CONNECTOR
J26-17 N/A J26-18 KEYSWITCH B+ OUT P26-15
GENSET VOLTAGE P22-1
RING TERMINAL
P26-1 P1939 SHLD
P22-2
P26-10 P1939 (-)
P22-3
G
SEE SHEET 5
J26-5 AVR B+ RETURN P12-1
ALTERNATOR
C SEE SHEET 5 SEE SHEET 5
AUX 101 IS REQUIRED FOR EXHAUST TEMPERTURE SENSING.
P26-2
-
KS
B1-SW1
SEE SHEET 5
B
J26-3 AVR PWM-
P12-4
P26-11 P1939 (+)
P22-4
120 ohm
B
Opens @ 85F, Closes @ 65F
P26-12 PCC NET A (+) P26-13 PCC NET B (-) P26-4 SHLD
AUX 104
V
P21-8 P21-2 P21-3
HM ECM & AVR
U
GOV POWER STAGE
P21-12
AUX 105
TERMINAL BLOCK W
4
TB15-5 WAKE-UP3
TB7-3
P12-5
N
8 9
P12-2
B
7
TB15-4 RS485 B
SEE FUSING REQUIREMENTS ON SHEET 1.
P6-2 B+ RETURN P6-1 HMI FUSED B+
DRIVER RATING S: 4 AMPS PEAK : 6 AMPS +
PC TOOL
K16
TB15-3 RS485 A
P1-4 PCC NET B(-) P1-5 SYSTEM WAKE-UP
P11 P10
CT3
TB7-1 USE PT’s IF LL VOLTAGE >600VAC
KS
CI#4 FUEL LEVEL SWITCH (WAKE-UP)
REMOTE I/O
P14-2 REMOTE E-STOP 2B
TB15-1 GND
1B BUS L1
M
BT2
AUX 101
P1-1
TB1-14 SEE SHEET 5 TB1-15
BUS VOLTAGE
M
CI#12 RUPTURE BASIN SWITCH (WAKE-UP)
P1-2
TB15-5 WAKE-UP3
CT3-6B
HMI 114
KS
KS
B1-SW2
RUPTURE BASIN RETURN
TB1-13 SEE SHEET 5
TB1-16
HARNESS, BUS: A035E847
BT1
B1-BAT
G
P1-3
TB1-11 SEE SHEET 5 TB1-12 SEE SHEET 5
CT2
CT3-5B
G1-D+
ENG SP3
P2-2 P2-4
CT2-4B SP2
P2-9
CUSTOMER INPUTS 1B FUEL LEVEL RETURN
TB1-10 SEE SHEET 5
BUS CURRENT CT1
CT2-3B
COOLANT LEVEL (S7)
Starter 2
Starter 1
GND-ENG
P2-3
TB1-9 SEE SHEET 5
CT1-2B SP1
P28-3 B+ RETURN
B+ RETURN
P2-1
TB1-7 SEE SHEET 5 TB1-8 SEE SHEET 5
P29-3 SYSTEM WAKE-UP BUS CT SHORTING BLOCK CT1-1B
K4+
G1-B+
B1-GND
TB1-2 PCC NET B (-)
P25-8
P28-1 HMI FUSED B+
1B 3B
TB1-3 B+ RETURN TB1-5 CUSTOMER FUSED B+
HARNESS, INTERFACE (PCC3300 TO HMI): A035G075
P25-5
D
TB1-1 PCC NET A (+)
P25-4 SP3
25OCT12
T.AJAYI
P20-8
P25-3
P29-1 PCC NET (+)
DATE
APVD
S2
P20-19
J25-1
P29-2 PCC NET (-)
K4
K4-BAT K4
B1-BAT
P2-8
P20-18
P25-10 J25-7 J25-12 P25-9
S1
G1-GND
P20-12
USE SHIELDED TWISTED PAIR FOR PCC NET ONLY TERMINATE SHIELD ON ONE END
JTB
HEATER CONTROL (P3)
P20-7
P20-6
P25-6
B1-BAT
SHIELD GROUNDED IN FOUR PLACES
P20-1
P29-4 AUTO (CONFIGURABLE WAKE-UP)
X20 (20A)
BATTERY CHARGING ALTERNATOR 24VDC
FSO (K1)
P2-11
GND SIG
TB15-5 WAKE-UP1
P3-B P3-A P3-C
X21 (20A)
B+
P29 must be disconnected to use PC Tools on TB15
B1-BAT
TLD
5B
S7-B S7-D
HARNESS ENGINE: A035H837
X10 (10A)
DWN CKD
-
TB-BAT
S7-C
HARNESS, INTERFACE (WORT BOX): A035H282
-
K9-1
P2-15
SwB+ - 3B B
A
C
4B
HMI-SP1 F-FSO 3A
P20-5
FUSED B+
2B 3B
P20-22
DISPLAY
C
1B
SP4
P2-14 ENG SP4
P20-2 P20-4
TB15-4 RS485 B
PART NUMBERS: HMI 320: 0300-6315-02
K4-S1
INPUT (WAKE-UP ON OPEN) P25-2
PC TOOL
HARNESS, INTERFACE PC TOOL: A035A671
P2-10
ECO - 129979
REVISION
2B
P2-13
FSO K8
P20-20 P20-21
PART NUMBERS PCC3300: 0327-1601
1
NO
J20-11
4
6
P2-6
P-SWB+
LTR
T26
P2-12
P20-17
TB15-1 GND TB15-3 RS485 A
HMI 320
5
P20-9 P20-10
LOCAL E-STOP B+ 4
J20-16 Oil Priming Pump Relay Driver P20-3 P20-15 P20-14
4B GND
3
Starter K9
1 REL NO
3B
S7-B
1
6
P2-5
T26
J20-13 Relay Coil B+ Supply
SW B+
1B
4
3300 TB1-15
REMOVE JUMPERS 1 AND 2 TO INSTALL REMOTE ESTOP
2
3
CT21-1 CT-23
POWERSTAGE
B+ RETURN - 1B
CT21-2/3 CT22-1
P21-6
K10-SP
P21-9
FUSED B+ - 3B
87
85
30
86 E-STOP B+ - 2B
P21-11
PART NUMBERS AUX 105: A028T766
CT23-1 CT-21
J1-5 J1-4 J1-3
P1 - 2 P1-5 GOV PS POWER P1-4 ACT LS DRIVER P1-3 GOV PS POWER
OIL PRESSURE (E1)
K10 KEYSWITCH
CT-22 CT22-2/3
J1-1 J1-2
Part numbers Aux 104: 0327-1507 P1 Mate: 0323-2216 : Sockets: 0323-1200
120 ohm
FUEL ACTUATOR (6AMP MAX) ACT (-) ACT (+)
P1 - 1
E1-B E1-A E1-C
CT23-2/3
P11-5 GOVERNOR PWM + P11-4 GOVERNOR PWM -
XU (.5A)
USE PT’s IF LL VOLTAGE >600VAC
XV (.5A)
MAG PICK-UP (P1) P1-A P1-B
P11-1 +5V P11-2 RETURN
XW (.5A)
P11-3 SENSE COOLANT TEMP LEFT BANK (E2) E2-A
PMG-P2 PMG-P3
P18-2
P11-10 -
PMG-P4
P18-3
P11-11 SENSE P11-12 RETURN
E4-A
P11-13 SENSE
E4-B
AVR CONTROL FIELD (+)
P17-1
FIELD (-)
P17-2
OIL TEMPERATURE (E4)
P11-14 RETURN P11-15 SENSE P11-16 RETURN
UNLESS OTHERWISE SPECIFIED, ALL DIMENSIONS ARE IN MILLIMETERS
PC TOOL
J5-3 J5-4 J5-5
TB15-1 GND TB15-3 RS485 A TB15-4 RS485 B
RS485 SHIELD
X `
COOLANT TEMP RIGHT BANK (E3) HARNESS, INTERFACE PC TOOL: A040G672
E3-A
DIM
J5-1
E3-B
.X `
TB15-5 WAKE-UP
.XX` ANG TOL: `
6
5
A
P11-9 +
PMG
G
E2-B
P11-8 SHIELD
4
3
HOLE
A
AVR POWER P18-1
0.00- 4.99 +0.15/-0.08 5.00- 9.99 +0.20/-0.10 10.00-17.49 +0.25/-0.13 17.50-24.99 +0.30/-0.13 SCALE :
SIM TO
DO NOT SCALE PRINT
- CONFIDENTIAL PROPERTY OF CUMMINS POWER GENERATION
2
DWN CKD
CUMMINS POWER GENERATION
N_SCHOTTLER N_SCHOTTLER
APVD
M_POZO
DATE
01-04-2011
FOR INTERPRETATION OF DIMENSIONING AND TOLERANCING, SEE ASME Y14.5M-1994
DIAGRAM, SCHEMATIC
SITE CODE FIRST USED ON
KTA38
PGK
DWG SIZE
D
SHEET
A035H705
2
OF
6
DWG REV
C
1
Drawing Name: A035H706 Revision: C Part Name: A035H705 Revision: C Sheet 2 of 7
VISIO
6
4
5
2
3
1 REL NO
LTR
NO
C
-
ECO - 129979
REVISION
DWN CKD
-
TLD
JTB
DATE
APVD
25OCT12
T.AJAYI
D
D
COOLANT TEMP RIGHT BANK (E3)
LOW COOLANT TEMPERATURE (S4)
COOLANT TEMP LEFT BANK (E2)
COOLANT LEVEL (S7)
MAG PICKUP (P1) A
C C
C
C A B
B
TB-BAT
K4 T 26
OIL TEMPERATURE (E4)
OIL PRESSURE (E1)
GND ENG
B
B
COOLANT LEVEL (S7)
SEE NOTE 1
HMI 114
HMI 320
- LOW COOLANT LEVEL SENSOR (S7) IS LOCATED AT THE TOP OF THE RADIATOR. - NOT ALL CONNECTION POINTS ARE SHOWN, SEE SPECIFIC HARNESS INSTALLATION DRAWINGS FOR EACH OPTION FOR MORE INFORMATION.
A
A
RADIATOR VIEW
CT-21
CT-23
LOCAL E-STOP DIM
X `
VIEW A-A
VIEW B-B
UNLESS OTHERWISE SPECIFIED, ALL DIMENSIONS ARE IN MILLIMETERS
.X `
5
4
0.00- 4.99 +0.15/-0.08 5.00- 9.99 +0.20/-0.10 10.00-17.49 +0.25/-0.13 17.50-24.99 +0.30/-0.13
.XX` ANG TOL: `
6
HOLE
CT-22
3
SCALE :
SIM TO
DWN
N_SCHOTTLER
DO NOT SCALE PRINT
CKD
N_SCHOTTLER
APVD
M_POZO
DATE
01-04-2011
- CONFIDENTIAL - FOR INTERPRETATION
PROPERTY OF CUMMINS POWER GENERATION
2
OF DIMENSIONING AND TOLERANCING, SEE ASME Y14.5M-1994
CUMMINS POWER GENERATION SITE CODE
FIRST USED ON
KTA38
DIAGRAM, SCHEMATIC DWG SIZE
PGF D
A035H705
SHEET
3
OF
6
DWG REV
C
1
Drawing Name: A035H706 Revision: C Part Name: A035H705 Revision: C Sheet 3 of 7
VISIO
6
4
5
2
3
1 REL NO
LTR
NO
ECO - 129979
C
-
REVISION
DWN CKD
-
TLD
JTB
APVD
DATE
T.AJAYI
25OCT12
D
C
SWITCH (WAKE-UP)
CI#12 RUPTURE BASIN
MODBUS
SWITCH (WAKE-UP)
K16
CI#4 FUEL LEVEL
D
REMOTE E-STOP
K22
E-STOP B+
1 A
2 A
3 4 A A
5 A
1 A
2 A
3 4 A A
1 A
2 A
3 4 A A
1 A
2 A
3 4 A A
1 A
2 A
3 4 A A
5 A
1 A
2 3 A A
4 5 A A
1 A
2 A
3 4 A A
5 A
1 B
2 B
3 4 B B
5 B
1 B
2 B
3 4 B B
1 B
2 B
3 4 B B
1 B
2 B
3 4 B B
1 B
2 B
3 4 B B
5 B
1 B
2 3 B B
4 5 B B
1 B
2 B
3 4 B B
5 B
BUS CT SHORTING BLOCK
K17
OPTIONAL RELAYS 6X (K13,K14,K15,K19,K20,K21)
B+ RETURN
SW B+
FUSED B+
FAT (2A)
K18
K23
F-FSO (3A)
1A
2A
3A
4A
5A
6A
HEATER POWER
A
1 A
B
1 2 3 4 5 B B B B B L L L/N L/N G 1B
2B
3B
4B
5B
2 A
3 4 A A
BUS VOLTAGE 5 A
1 A
2 A
3 A
4 A
1 2 3 4 B B B B L1 L2 L3 N
C
6B
AUX 104
TB8
TB1 K7
K8
J18
K9
TB3
J 1
TB5
TB10 J14
J26
J25 TB 15
J4
J3
J 11
J20 J21 J2
J11
TB 15 J14
A
CT2
CT3
J1
TB7
J22
DIM
X `
VIEW C-C
UNLESS OTHERWISE SPECIFIED, ALL DIMENSIONS ARE IN MILLIMETERS
.X ` .XX`
ANG TOL: `
4
A
3300
AUX 105
5
CT1
J12
AC WIRE ENTRANCE
AUX 101
6
B
TB 9
3
HOLE
B
DC WIRE ENTRANCE
J17
J 10
0.00- 4.99 +0.15/-0.08 5.00- 9.99 +0.20/-0.10 10.00-17.49 +0.25/-0.13 17.50-24.99 +0.30/-0.13 SCALE :
SIM TO
DWN
DO NOT SCALE PRINT
CKD
N_SCHOTTLER
APVD
M_POZO
DATE
01-04-2011
- CONFIDENTIAL - FOR INTERPRETATION
PROPERTY OF CUMMINS POWER GENERATION
2
CUMMINS POWER GENERATION
N_SCHOTTLER
OF DIMENSIONING AND TOLERANCING, SEE ASME Y14.5M-1994
SITE CODE FIRST USED ON
KTA38
DIAGRAM, SCHEMATIC DWG SIZE
PGK D
A035H705
SHEET
4
OF
6
DWG REV
C
1
Drawing Name: A035H706 Revision: C Part Name: A035H705 Revision: C Sheet 4 of 7
VISIO
6
4
5
2
3
1 REL NO
ECO - 129979
LTR
NO
C
1
REVISION REMOVE TB10-5 B+ AND TB10-10 GND CONNECTIONS, ADD B+ RETURN -2B AND FUSED B+ -1A (ZONE D-5)
DWN CKD
APVD
DATE
TLD
T.AJAYI
25OCT12
JTB
PARALLELING CIRCUIT BREAKER RELAY CONTROL
OPTIONAL RELAYS PCC 3300 TB1 13
21
43
43
A2
14
22
44
44
ALARM RELAY K21
RTD CONNECTIONS ALARM MODULE FUSED B+ -1A
D
PCC 3300 TB1
TB1-5
B+
K19
TB1-6 TB1-8 TB1-9
A1
13
21
43
43
A2
14
22
44
44
CONFIGURABLE RELAY K13
A1
13
21
43
43
A2
14
22
44
44
J22-4 (N)
PCC 3300 TB8
A1
13
21
43
43
A2
14
22
44
44
TB1-5
B+
J2-
TB1-8
A1
13
21
43
43
A2
14
22
44
44
CONFIGURABLE RELAY K15
RED
FAT (2A)
RED WHITE
PCC 3300 TB8-7
A1
CIRCUIT BREAKER TRIPPED
K18 (TEMPERATURE MONITORING)
PC3300 TB10
A2
16
18
26
28
25
13
21
43
43
A2
14
22
44
44
TB10-2
TB1-10
GND
W2
RED WHITE
TB1-9
A1
RTD
RED 15 Tb
Generator Circuit Breaker
RTD
RED
SDE Contact
V2
RED
K17 (DELAYED MAKE)
RTD
WHITE RED
CLOSE STATUS OUTPUT
TB5
U2
RED WHITE
PCC 3300 TB8-12
RTD
RED
TB8-9
W1
RED WHITE
OPEN STATUS OUTPUT
TB8-10
N.D.E BEARING D.E BEARING
RED WHITE
R
PTC Ta
RTD
RED
J1+
CONFIGURABLE RELAY K14 K20
J22-3 (W)
D
WHITE
K17 (TIMER 0-10SEC)
AUDIBLE ALARM MODULE
B+ RETURN -2B
TB1-10
GND
THERMISTOR RELAY
RESET
A1
TB10-10
RTD
RED
C ALT. TEMP THERMISTORS
C
V1
RED WHITE
RTD
RED
U1
RED
RTD
HEATERS (COOLANT, CONTROL BOX, ALTERNATOR) HEATER CONTROL BOX Fuel Level
GROUND FAULT RELAY PCC 3300 TB8
B+ RETURN - 2B
RHI1 RHI1
High level warning
HT2
5
3
8
6
4
1
B
K22 RH99M
PCC 3300 TB1-13
BATT -VE (B+ RETURN)
- WIRING DIAGRAMS SHOWN ON THIS SHEET ARE GENERALIZED, SEE SPECIFIC INSTALLATION DRAWINGS FOR EACH OPTION FOR MORE INFORMATION.
TB8-13 Low Fuel warning
TB1-12
HE2
SHUNT TRIP
Customer Inputs Terminal block 1A
2A
3A
4A
1B
2B
3B
4B
RESET
CONTROL BOX HEATER
Low Fuel Shutdown 1A
2A
3A
4A
5A
1B
2B
3B
4B
5B
ALTERNATOR HEATER Ground Fault Relay is available on single set applications only.
A
14
32 31 34 25 26 27 11
ST-1 ST-2
TEST
TB1-13
ON (RELAY OPERATIONAL)
BATT +VE (SW B+) HE1
T2
PCC 3300 TB1-14 TB8-8
K23
HT1
T1
A1 A2
90
126
E
255
254
253
252
250
N
L
E
CT3
PCC 3300 TB1
FUSE1 4A
B
CT1
Fused B+ - 1A
A
HP HA UNLESS OTHERWISE SPECIFIED, ALL DIMENSIONS ARE IN MILLIMETERS
.X ` .XX`
ANG TOL: `
6
5
4
3
HOLE
DIM
X `
0.00- 4.99 +0.15/-0.08 5.00- 9.99 +0.20/-0.10 10.00-17.49 +0.25/-0.13 17.50-24.99 +0.30/-0.13 SCALE :
SIM TO
DO NOT SCALE PRINT
- CONFIDENTIAL PROPERTY OF CUMMINS POWER GENERATION
2
DWN
CUMMINS POWER GENERATION
N_SCHOTTLER
CKD
N_SCHOTTLER
APVD
M_POZO
DATE
01-04-2011
FOR INTERPRETATION OF DIMENSIONING AND TOLERANCING, SEE ASME Y14.5M-1994
DIAGRAM, SCHEMATIC
SITE CODE FIRST USED ON
KTA38
PGK
DWG SIZE
D
SHEET
A035H705
5
OF
6
DWG REV
C
1
Drawing Name: A035H706 Revision: C Part Name: A035H705 Revision: C Sheet 5 of 7
VISIO
6
PCC3300 BASEBOARD PART NUMBERS PCC3300: 0327-1601
4
5
2
3
1 REL NO
LTR
NO
ECO - 129979
C
-
REVISION
DWN CKD
-
TLD
JTB
APVD
DATE
T.AJAYI
25OCT12
TB1-1 PCC NET A (+) SEE SHEET 2 TB1-2 PCC NET B (-) SEE SHEET 2
PCC3300
TB1-3 B+ RETURN SEE SHEET 2 TB1-5 CUSTOMER FUSED B+ SEE SHEET 2 TB1-4 CONFIGURABLE O/P #5
BASEBOARD
AUX 101 REMOTE I/O
PART NUMBERS PCC3300: 0327-1601
TB1-6 CONFIGURABLE O/P #1-A
D
J2-1 RELAY 1 NO
TB1-7 CONFIGURABLE O/P #1-B TB1-8 CONFIGURABLE O/P #2-A
TB8-1 DISCRETE INPUT RETURN
J2-2 RELAY 1 COM
TB8-2 DISCRETE INPUT RETURN
J2-3 RELAY 1 NC
TB1-9 CONFIGURABLE O/P #2-B
TB8-3 DELAYED OFF RELAY DRIVER
J2-4 RELAY 2 NO
TB1-10 REMOTE START RETURN
TB8-4 SWITCHED B+ RELAY DRIVER
J2-5 RELAY 2 COM
TB1-11 REMOTE START TB1-12 CONFIGURABLE I/P #1
TB8-5 REMOTE FAULT RESET TB8-6 START TYPE
J2-7 RELAY 3 NO
TB1-13 RETURN TB1-14 CONFIGURABLE I/P #2
TB8-7 CONFIGURABLE INPUT #13
J2-8 RELAY 3 COM
TB8-8 CONFIGURABLE INPUT #14
J2-9 RELAY 3 NC
TB1-15 REMOTE E-STOP SEE SHEET 2 TB1-16 REMOTE E-STOP SEE SHEET 2
TB8-9 CONFIGURABLE OUTPUT #4
J2-10 RELAY 4 NO
TB8-10 CONFIGURABLE OUTPUT #3
J2-11 RELAY 4 COM
TB8-11 LOAD DUMP RELAY DRIVER
J2-12 RELAY 4 NC
J2-6 RELAY 2 NC
TB8-12 DISCRETE INPUT RETURN TB3-1 RETURN
TB8-13 DISCRETE INPUT RETURN
TB3-2 MASTER CAN SHIELD
J3-1 RELAY 5 NO
TB3-3 MASTER CAN L
J3-2 RELAY 5 COM
TB3-4 MASTER CAN H
J3-3 RELAY 5 NC
TB3-5 CONFIGURABLE OUPUT #20 STATUS TB3-6 CONFIGURABLE OUPUT #21 STATUS TB3-7 SPARE OUTPUT FOR FURTURE USE TB3-8 CONFIGURABLE OUPUT #22 STATUS
TB9-1 KW LOAD SETPOINT
J3-4 RELAY 6 NO
TB9-2 ANALOG RETURN
J3-5 RELAY 6 COM
TB9-3 KVAR LOAD SETPOINT
J3-6 RELAY 6 NC
C
TB9-4 VOLTAGE BIAS OUTPUT / CONFIGURABLE ANALOGY OUTPUT #2 OUTPUT PREDICTOR
TB3-9 TRANSFER INHIBIT/CONFIGURABLE INPUT #20 SWITCH
TB9-5 SPEED BIAS OUTPUT / CONFIGURABLE ANALOG OUTPUT #1 OUTPUT PREDICTOR
TB3-10 RETRANSFER INHIBIT/CONFIGURABLE INPUT #21 SWITCH TB3-11 MASTER FIRST START STATUS TB3-12 RETURN
TB9-6 ANALOGY RETURN
J4-1 RELAY 7 NO
TB9-7 KW LOAD SHARE LEVEL TB9-8 NOT USED
J4-2 RELAY 7 COM J4-3 RELAY 7 NC
TB9-9 LOAD SHARE SHIELD
J4-4 RELAY 8 NO
TB5-1 GENSET CB CLOSE STATUS
TB9-10 + KVAR LOAD SHARE LEVEL
J4-5 RELAY 8 COM
TB5-2 GENSET CB CLOSE STATUS
TB9-11 - KVAR LOAD SHARE LEVEL
J4-6 RELAY 8 NC
TB5-3 GENSET CB OPEN STATUS TB5-4 GENSET CB OPEN STATUS
J10-1 CAN H
TB5-5 GENSET CB OPEN STATUS
J10-2 CAN L
TB5-6 UTILITY CB CLOSE STATUS
J10-3 INPUT #3 CURRENT SOURCE (SEE SHEET 2)
TB5-7 UTILITY CB CLOSE STATUS
J10-4 INPUT #4 CURRENT SOURCE (SEE SHEET 2)
TB5-8 UTILITY CB OPEN STATUS
TB10-1 RETURN
TB5-9 UTILITY CB OPEN STATUS
TB10-2 RETURN
J10-5 INPUT #5 CURRENT SOURCE J10-6 INPUT #6 CURRENT SOURCE
TB10-3 UTILITY CB POS A SWITCH
J10-7 5VDC SUPPLY #1 (20 mA MAX)
TB10-4 UTILITY CB POS B/CONFIGURABLE INPUT #23 SWITCH
J10-8 5VDC SUPPLY #2 (20 mA MAX)
TB10-5 UTILITY CB TRIPPED SWITCH
J10-9 INPUT #3 CURRENT RETURN (SEE SHEET 2)
TB10-6 UTILITY CB INHIBIT/CONFIGURABLE INPUT #25 SWITCH
J10-10 INPUT #4 CURRENT RETURN (SEE SHEET 2)
TB10-7 GENSET CB POS A SWITCH
J10-11 INPUT #5 CURRENT RETURN
TB10-8 GENSET CB POS B/CONFIGURABLE INPUT #26 SWITCH
B
J10-12 INPUT #6 CURRENT RETURN
TB10-9 RETURN TB10-10 GENSET CB TRIPPED SWITCH TB10-11 GENSET CB INHIBIT/CONFIGURABLE INPUT #28 SWITCH
J11-1 INPUT #1 RETURN
TB10-12 UTILITY SINGLE MODE VERIFY/CONFIGURABLE INPUT #29 SWITCH TB10-13 SYNC ENABLE/CONFIGURABLE INPUT #28 SWITCH
J11-2 INPUT #1 SENSE J11-3 INPUT #2 RETURN
TB10-14 LOAD DEMAND STOP CONFIGURABLE I/P#31
J11-4 INPUT #2 SENSE
TB10-15 RAMP LOAD/UNLOAD CONFIGURABLE I/P#32
J11-5 INPUT #3 SENSE RETURN (SEE SHEET 2)
TB10-16 RETURN
J11-6 INPUT #3 SENSE (SEE SHEET 2)
TB10-17 RETURN
J11-7 INPUT #4 SENSE RETURN (SEE SHEET 2) J11-8 INPUT #4 SENSE (SEE SHEET 2) J11-9 INPUT #5 SENSE RETURN J11-10 INPUT #5 SENSE J11-11 INPUT #6 SENSE RETURN J11-12 INPUT #6 SENSE J11-13 INPUT #7 RETURN J11-14 INPUT #8 SENSE (ANALOG 0-38VDC) J11-15 INPUT #8 RETURN J11-16 INPUT #8 SENSE (ANALOG 0-38VDC)
A
A
UNLESS OTHERWISE SPECIFIED, ALL DIMENSIONS ARE IN MILLIMETERS
.X ` .XX`
ANG TOL: `
6
5
4
3
HOLE
DIM
X `
0.00- 4.99 +0.15/-0.08 5.00- 9.99 +0.20/-0.10 10.00-17.49 +0.25/-0.13 17.50-24.99 +0.30/-0.13 SCALE :
SIM TO
DO NOT SCALE PRINT
- CONFIDENTIAL PROPERTY OF CUMMINS POWER GENERATION
2
DWN
CUMMINS POWER GENERATION
N_SCHOTTLER
CKD
N_SCHOTTLER
APVD
M_POZO
DATE
01-04-2011
FOR INTERPRETATION OF DIMENSIONING AND TOLERANCING, SEE ASME Y14.5M-1994
DIAGRAM, SCHEMATIC
SITE CODE FIRST USED ON
KTA38
PGK
DWG SIZE
D
SHEET
A035H705
6
OF
6
DWG REV
C
1
Drawing Name: A035H706 Revision: C Part Name: A035H705 Revision: C Sheet 6 of 7
Part A035H705 C Description
Legacy Name
External Regulations
Application Status
Release Phase Code
Security Classification
DIAGRAM,SCHEMATIC
A035H705
None
Production & Service
Production
Proprietary
Alternates
Part Specifications :A035H705 C Name
Description
A030B356
SPECIFICATION,MATERIAL
Legacy Name CES10903
A035H706
DRAWING,ENGINEERING
A035H706
Drawing Name: A035H706 Revision: C Part Name: A035H705 Revision: C Sheet 7 of 7
View more...
Comments