Description
CONTROL SYSTEM LAB
Transfer Function of DC Servo Motor
Contents INTRODUCTION ....................................................................................... 3 Specification............................................................................................ 6 DC Servo Motor.................................................................................... 6 Front Panel Description ....................................................................... 6 Armature volt adjustment.................................................................... 6 Field Volt Adjustment .......................................................................... 7 PRINCIPLE OF OPERATING....................................................................... 7 TRANSFER FUNCTION OF DC SERVO MOTOR ....................................... 9 Armature Controlled D.C. Servo Motor .............................................. 12
Join the Technical Community Today! http://www.pantechsolutions.net
INTRODUCTION In the dc motor that includes two windings; a stationary field winding on the stator and a second winding for the rotating armature. This type of motor can be controlled by varying either the field current or the armature current. Most modern servomotors are somewhat different in construction. The field winding is replaced with two or more powerful rare‐earth magnets on the stator. Since the field strength of these motors is constant, they can only be controlled by varying the armature current, in a permanent magnet motor the output torque, is directly proportional to the armature current, The constant of proportionality is referred to as the torque constant of the motor and is represented . The transfer function relating motor torque to armature current can be expressed as follows: DC motor that includes two windings; a stationary field winding on the stator and a second winding for the rotating armature. This type of motor can be controlled by varying either the field current or the armature current. Most modern servomotors are somewhat different in construction. The field winding is replaced with two or more powerful rare‐earth magnets on the stator. Since the field strength of these motors is constant, they can only be controlled by varying the armature current, In a permanent magnet motor the output torque, is directly proportional to the armature current, The constant of proportionality is
Join the Technical Community Today! http://www.pantechsolutions.net
referred to as the torque constant of the motor and is represented The transfer function relating motor torque to armature current can be expressed as follows:
ABOUT OUR TRAINER Pictorial View
Front Panel View
Join the Technical Community Today! http://www.pantechsolutions.net
Join the Technical Community Today! http://www.pantechsolutions.net
Specification Armature voltage Va
0 - 50V DC
Field Voltage
0 - 50VDC
Vf
AC voltage
0 – 20 VAC.
DC Servo Motor Armature winding voltage
50V DC
Field winding voltage
50V DC
Power
120W
Armature current (Ia)
2.6A(max)
Moment of inertia (J)
g/cm2.
Front Panel Description DC voltmeter DC Ammeter AC voltmeter AC Ammeter
Armature volt adjustment
Join the Technical Community Today! http://www.pantechsolutions.net
Pot
= Adjust the armature voltage from 3V to 50V.
Pot
= Adjust the armature voltage from 3V to 50V.
A and AA = Connect to the motor armature terminal respectively.
Field Volt Adjustment Pot
= Adjust the field voltage from 0V to 50V.
Switch ‘S2' = Switch ON/OFF the field voltage. F and FF
= Connect to the motor field terminal respectively.
AC voltage = Adjust the AC voltage from 0V to 20V. AC output (P&N) = AC output voltage.
PRINCIPLE OF OPERATING A DC motor is used in a control system where an appreciable amount of shaft power is required. The DC motors are either armature-controlled with fixed field, or field-controlled with fixed armature current. DC motors used in instrument employ a fixed permanent-magnet field, and the control signal is applied to the armature terminals.
Join the Technical Community Today! http://www.pantechsolutions.net
Km = Proportionality constant Tm = Motor torque Nf = Field flux ia = Armature current
In addition to the torque when conductor moves in magnetic field, voltage is generated across its terminals which opposes the current flow and hence called as Back e.m.f denoted as eb
This back e.m.f is directly proportional to the shaft velocity Tm. Equations (i) and (ii) form the basic equation of d.c. servo motor operation.
Basic Classification Basically d.c. servo motors are classified as: (i) Variable magnetic flux motors. (ii) Constant magnetic flux motors.
Join the Technical Community Today! http://www.pantechsolutions.net
In variable magnetic flux motors magnetic field is produced by the field windings which are connected to the external supply. These are also called as separately excited or field controlled motors.
TRANSFER FUNCTION OF DC SERVO MOTOR
The constant magnetic flux motors are also known as permanent magnet d.c. motors. These motors have relatively linear torque-speed characteristics. Derivation of transfer functions for (i) Field controlled d.c. servo motor (ii) Armature controlled d.c. servo-motors.
Join the Technical Community Today! http://www.pantechsolutions.net
ii. Field Controlled DC Servo motor
Assumptions (1) Constant armature current is fed into the motor. (2) Nf % If. Flux produced is proportional to field current. Nf = Kf If (3) Torque is proportional to product of flux and armature current. Tm % N Ia . Tm = K` N Ia = K’ Kf If Ia Tm = Km Kf If Where Km = K` Ia = constant Apply kirchoff’s law to field circuit.
Now shaft torque Tm is used for driving load against the inertia and frictional torque.
Join the Technical Community Today! http://www.pantechsolutions.net
Finding Laplace Transforms of equations (1), (2) and (3) we get,
Tm (s) = Km Kf If(s) Ef (s) = (SLf + Rf) If (s) Tm (s) = Jms 2m (s) + Bms2m (s)
Eliminate If (s) from equations (4) and (5)Input = Ef(S) Output = Rotational displacement 2m (S)
Join the Technical Community Today! http://www.pantechsolutions.net
Armature Controlled D.C. Servo Motor Join the Technical Community Today! http://www.pantechsolutions.net
Assumptions: (i)
Flux is directly proportional to current through field winding. Nm = Kf If = constant
(ii) Torque produced is proportional to product of flux and armature current.
T = K`m N Ia T = K`m Kf If Ia
(iii) Back e.m.f is directly proportional to shaft velocity Tm, as flux N is constant.
Apply Kirchhoff’s law to armature circuit:
Join the Technical Community Today! http://www.pantechsolutions.net
Also Tm = {Jms + sBm} 2m (s) 2 Equating equations of Tm,
Join the Technical Community Today! http://www.pantechsolutions.net
Where Jm = Jm/Bm and
Join the Technical Community Today! http://www.pantechsolutions.net
Join the Technical Community Today! http://www.pantechsolutions.net
Did you enjoy the read? Pantech solutions creates information packed technical documents like this one every month. And our website is a rich and trusted resource used by a vibrant online community of more than 1, 00,000 members from organization of all shapes and sizes.
Join the Technical Community Today! http://www.pantechsolutions.net
What do we sell? Our products range from Various Microcontroller development boards, DSP Boards, FPGA/CPLD boards, Communication Kits, Power electronics, Basic electronics, Robotics, Sensors, Electronic components and much more . Our goal is to make finding the parts and information you need easier and affordable so you can create awesome projects and training from Basic to Cutting edge technology.
Join the Technical Community Today! http://www.pantechsolutions.net
View more...
Comments