User Manual for TDC3000(V1.3.3)

March 7, 2018 | Author: Said Wahdan | Category: Capacitor, Electrical Connector, Power Supply, Mains Electricity, Transformer
Share Embed Donate


Short Description

Descripción: haomi tan delta user manual...

Description

Tan Delta and Capacitance Tester TDC3000

User Manual (V1.3.3)

Content 1.Safety Instruction……………………………………………………………………………….........2 2.Applications…………………………………………………………………………………………..2 3.Technical Index………………………………………………………………………………………3 4. Test Wiring Connection……………………………………………………………………………..3 4.1 Definitions…………………………………………………………………………………………..3 4.2 Test Wiring Connection Diagram…………………………………………………………………...4 4.3 GSTG with internal power and internal reference capacitor………………………………………..9 4.4 Shield Layer of Low Voltage Cables………………………………………………………………11 4.5 Typical Applications in Power System…………………………………………………………….12 5.Operation Guide………………………………………………………………………………........20 5.1 Protection Units……………………………………………………………………………………20 5.2 Panel of Tester……………………………………………………………………………………...21 5.3 Operation of Tester………………………………………………………………………………...23 6.Trouble Shooting……………………………………………………………………………………26 7.Package List…………………………………………………………………………………………26

1

1.Safety Instruction 1) The tester must be connected to earth properly before use. 2) The HV output terminals should be clean before starting test. 3) The test voltage is very high, so the users must keep enough safe distance from the sample and 4) 5) 6) 7)

high voltage circuit. The tester should be power off when making wiring connections. It is forbid to touch the terminals and cables when testing. Any replacement should be made after tester is switched off The tester should not be connected to the live power line at all.

8) The operator or user should get a certification of high voltage electrical test from local professional institute. 9) Please do not use the tester in rain, high temperature, large amount of dust environment 10) The tester should be repaired by certificated engineer in case that there is fault. The above warnings should be read and understood before using the tester.

2.Applications Tan Delta and Capacitance Tester TDC3000 is applied to measure the dissipation factor (PF) of insulating materials in heavy interference site, such as power plants, power substations etc.. It also can be applied in laboratory for high accuracy capacitance and dissipation measurement. The tester is all-in-one design: including precision digital bridge, power unit, internal reference capacitor (Cn), booster transformer and other electronic circuits. The typical applications of Tan Delta and Capacitance Tester TDC3000 are as following: 1)measure the dissipation & capacitance of power transformer and distribution transformer 2)measure the dissipation & capacitance of current transformer and voltage transformer 3)measure the dissipation & capacitance of high voltage circuit breaker 4)measure the dissipation & capacitance of high voltage motor 5)measure the dissipation & capacitance of insulation bushing

3.Technical Index The detailed technical indexes of TDC3000 are as following: 1)Test Standard: IEC60247 2)Dielectric Dissipation Factor(tgδ) measuring range: no limit accuracy: ±(reading×1%+0.00040) resolution: 0.001%

2

3)Capacitance (Cx) measuring range: Internal HV: 3pF~60000pF/10kV, 60pF~1uF/0.5kV External HV: 3pF~1.5μF/10kV, 60pF~30μF/0.5kV accuracy: ±(reading×1%+1 pF) resolution: 0.001pF(4 valid digital) 4)Input Current Range: 10μA~5A 5)Internal HV adjustment: rise or fall smoothly range: 0.5~10kV / 200mA (max.) accuracy: ±(reading×1%+10V) resolution: 100V 6)CVT Output: voltage: 3~50V, current: 3~30A 7)Frequency Selection range: 50Hz or 60Hz (single point, locked) 45Hz/55Hz, 55Hz/65Hz (double variable point, locked) accuracy: ±0.01Hz 8)Interference Ratio: interference current is no more than 2 times of test current 9)Test Time: 40s typical 10)RS232 interface 11)Built-in micro-thermal printer 12)Power Supply: AC180V~270V, 50Hz/60Hz 13)Environmental Condition storage temperature: -20℃~60℃ operating temperature: -10℃~50℃ humidity: 1 displays Rx and

Inductive

Lx,Q,U,I,φ,P,F,t

Resistive

Cx(Lx),Rx,U,I,φ,P,F,t seriated Lx

Cx, if |Q|
View more...