Training - 2G BSS Statistic Counter and KPI Formula.pdf

April 17, 2018 | Author: Dadan Dawud | Category: Performance Indicator, Nokia, Computer Networking, Data Transmission, Digital & Social Media
Share Embed Donate


Short Description

2G BSS Statistic Counter and KPI Formula...

Description

2G BSS Statistic Counter and KPI Formula

1

© Nokia Siemens Networks

Contents  Background  Measurement Report  BSS Counters  KPIs  What’s BSS Network Doctor  How To Grab Statistic From Reporting Suite  NED Introduction (related to counter)  Performance Report  Performance Indicator Sample  T3-RG10-Gemini Formula

2

© Nokia Siemens Networks

Background  To provide information related to 2G BSS Statistic, counter, and KPI

Formula which daily used

3

© Nokia Siemens Networks

Measurement Report

4

© Nokia Siemens Networks

BSS Counters Performance Measurements

Performance measurements and observations are divided into the

following groups according to their function:    

Call control measurements (CSW) GPRS measurements (PSW) Transmission measurements Observations

Performance Measurements Hierarchy

Report KPI

Aggregation Level PI Counters

Measurement Tables Measurements & Observations

5

© Nokia Siemens Networks

BSS Counters Measurement Tables • Measurements & Observations •Measurement Tables •Measurement Counters •(Aggregation level) Measurement tables of the Call Control measurements can be seen below Call Control measurements Traffic Measurement

Link Balance per MS Classmark Measurement

Reversed Hunting Measurement

Resource Availability Measurement

Timing Advance Statistics Measurement

Non-BCCH Layer Offset Measurement

Resource Access Measurement

Resource Availability per BSC Measurement

UTRAN Handover Adjacent Cell Measurement

Handover Measurement

BSC Level Clear Code (SERLEV) Measurement

UTRAN Neighbouring Cell Signal Level Measurement

Power Control Measurement

MS Speed Detection Measurement

Total FEP Measurement

Load Measurement

Dual Band Measurement

DFCA Measurement

Availability Measurement

C/I Ratio Measurement

DFCA Assignment Measurement

OSI/X.25 Measurement

Hot Spot Measurement

BSC-BSC Measurement

Undefined Adjacent Cell Measurement

High Speed Data Measurement

WPS Measurement

RX Quality Statistics Measurement

Channel Finder Measurement

IMSI-Based Handover Measurement

Handover Adjacent Cell Measurement

MS Capability Indication Measurement

CS DTM Measurement

BSC Level Clear Code Measurement

Defined Adjacent Cell Measurement

AMR RX Quality Measurement

BSC Level Clear Code (PM) Measurement

FER Measurement

DFCA SAIC Measurement

Underlay-Overlay Statistics Measurement

Position Based Services Measurement

Soft Channel Capacity Measurement

RX Level Statistics Measurement 6

© Nokia Siemens Networks

BSS Counters Measurement Tables

How to activate tables?  These can be activated at BSC level or can be activated at NetAct level.  If they are part of optional feature, the feature needs to be present on the PRFILE of each BSC. The parameter related to the feature needs to be activated.  Start date and End date needs to be defined.  Start time and End time of each day of the week needs to be defined  Period needs to be defined Set parameter in PR_FILE (WOC): ZWOC:10,65,FF; Set measurement (TPM): ZTPM:,:, ,:; ZTPM:MEASUR,CHAN_FIN:ALL,0–0–24–0,60:DB1=0,DB2=8; Start measurement (TPS): ZTPS:MEASUR,CHAN_FIN; *usually this is done by bcs engineer 7

© Nokia Siemens Networks

Active measurement table status sample

BSS Counters Measurement Tables

Measurement reporting interval to each measurement can be unique. – 15min, 30min, 1hour etc… During optimization these different measurement reporting intervals should be verified to support need of optimization activities.

Note! Any changes to measurement interval should be agreed with OSS administrator to avoid any overload situation in OSS.

 How to check that all data is available in OSS Can be checked running Reporting Suite reports – Some KPIs are using several tables, so if all data is not available, results might be strange. – If you want to check all data, all tables should be run

8

© Nokia Siemens Networks

BSS Counters Numbering Counter = XXXYYY where XXX = measurement table YYY = counter number in measurement table Example: counter 001001 or c1001 XXX = 001 = c1 = traffic measurement YYY = 001 = SEIZURE ATTEMPTS WITH BUSY SDCCH

Description in NED

9

© Nokia Siemens Networks

KPIs Performance Measurements Hierarchy

Report KPI

Aggregation Level PI Counters

Measurement Sample

Measurement Tables Measurements & Observations

KPI Formula Sample

 Performance Indicators (PIs) and Key Performance Indicators (KPIs) are created based on data in counters. – Tables must be activated and data must be available in OSS  Performance Reports are created based on KPI analysis 10

© Nokia Siemens Networks

What’s BSS Network Doctor BSS Network Doctor is a reporting package which provides effective tools to cover all functional areas of Nokia NetAct: Configuration Management, Fault Management, and Performance Management (PM), with special focus on the needs of network planning, operation and maintenance.

ND List 11

© Nokia Siemens Networks

How To Grab Statistic From Reporting Suite With Reporting Suite is easy to get statistic measurement in BSC or cell level and helpful for network monitoring and analysis purpose

How To Grab Statistic From Reporting Suite

12

© Nokia Siemens Networks

NED - Introduction From NED all the tables and counters with description can be found

Trigger point figures can be found from here

Counter data descriptions can be found from here

Tables can be found from here 13

© Nokia Siemens Networks

Performance Report

14

© Nokia Siemens Networks

Performance Indicator Sample Main KPI

accessbility

accessbility

15

© Nokia Siemens Networks

mobility

accessbility

retainability

retainability

Performance Indicator Sample Additional KPI

capacity

traffic

16

© Nokia Siemens Networks

capacity

Availability

traffic

traffic

T3-RG10-Gemini Formula Formula Table

*Same color is indicating same formula

17

© Nokia Siemens Networks

Thank You!!! 18

© Nokia Siemens Networks

View more...