Clash Manager (User)

TM-1221

TRAINING GUIDE

AVEVA Plant (12 Series)

www.aveva.com

AVEVA Plant (12 Series) Clash Manager (User) TM-1221

Revision Log Date 12/06/2008 27/06/2008 21/07/2008

Revision 0.1 0.2 1.0

Description of Revision Issued for Review Reviewed Approved for Training 12.0.0.3

Author

Reviewed

Approved

VJ VJ VJ

PF PF

RP

Updates All headings containing updated or new material will be highlighted.

Suggestion / Problems If you have a suggestion about this manual or the system to which it refers please report it to the AVEVA Group Solutions Centre at [email protected]

This manual provides documentation relating to products to which you may not have access or which may not be licensed to you. For further information on which products are licensed to you please refer to your licence conditions.

Visit our website at http://www.aveva.com

Disclaimer Information of a technical nature, and particulars of the product and its use, is given by AVEVA Solutions Ltd and its subsidiaries without warranty. AVEVA Solutions Ltd. and its subsidiaries disclaim any and all warranties and conditions, expressed or implied, to the fullest extent permitted by law. Neither the author nor AVEVA Solutions Ltd or any of its subsidiaries shall be liable to any person or entity for any actions, claims, loss or damage arising from the use or possession of any information, particulars or errors in this publication, or any incorrect use of the product, whatsoever.

Trademarks AVEVA and Tribon are registered trademarks of AVEVA Solutions Ltd or its subsidiaries. Unauthorised use of the AVEVA or Tribon trademarks is strictly forbidden. AVEVA product names are trademarks or registered trademarks of AVEVA Solutions Ltd or its subsidiaries, registered in the UK, Europe and other countries (worldwide). The copyright, trademark rights or other intellectual property rights in any other product, its name or logo belongs to its respective owner.

www.aveva.com 2

AVEVA Plant (12 Series) Clash Manager (User) TM-1221

Copyright Copyright and all other intellectual property rights in this manual and the associated software, and every part of it (including source code, object code, any data contained in it, the manual and any other documentation supplied with it) belongs to AVEVA Solutions Ltd. or its subsidiaries. All other rights are reserved to AVEVA Solutions Ltd and its subsidiaries. The information contained in this document is commercially sensitive, and shall not be copied, reproduced, stored in a retrieval system, or transmitted without the prior written permission of AVEVA Solutions Limited. Where such permission is granted, it expressly requires that this Disclaimer and Copyright notice is prominently displayed at the beginning of every copy that is made. The manual and associated documentation may not be adapted, reproduced, or copied in any material or electronic form without the prior written permission of AVEVA Solutions Ltd. The user may also not reverse engineer, decompile, copy or adapt the associated software. Neither the whole nor part of the product described in this publication may be incorporated into any third-party software, product, machine or system without the prior written permission of AVEVA Solutions Limited or save as permitted by law. Any such unauthorised action is strictly prohibited and may give rise to civil liabilities and criminal prosecution.

The AVEVA products described in this guide are to be installed and operated strictly in accordance with the terms and conditions of the respective licence agreements, and in accordance with the relevant User Documentation. Unauthorised or unlicensed use of the product is strictly prohibited.

Printed by AVEVA Solutions on 14 November 2008 © AVEVA Solutions and its subsidiaries 2001 – 2007 AVEVA Solutions Ltd, High Cross, Madingley Road, Cambridge, CB3 0HB, United Kingdom.

www.aveva.com 3

Contents 1

Introduction .............................................................................................................................................. 6 1.1 Aim .................................................................................................................................................... 6 1.2 Objectives ......................................................................................................................................... 6 1.3 Prerequisites .................................................................................................................................... 6 1.4 Course Structure.............................................................................................................................. 6 1.5 Using this guide ............................................................................................................................... 6 2 Clash Manager Login............................................................................................................................... 8 2.1 Access to Clash Manager ............................................................................................................... 8 2.1.1 Starting Clash Manager ............................................................................................................. 8 3 Creating Clash Sets ............................................................................................................................... 10 3.1 Add a new Clash Set...................................................................................................................... 11 3.2 Setting the Obstruction List.......................................................................................................... 11 3.3 Setting the Check List ................................................................................................................... 12 3.4 Setting the exclusion List ............................................................................................................. 13 3.4.1 Adding Items - Wildcards ......................................................................................................... 13 Exercise 5 – Clash Sets ................................................................................................................................ 16 4 Running a Clash Set .............................................................................................................................. 17 4.1 Running Clash Sets ....................................................................................................................... 17 4.1.1 Items on the Run Clash Set Dialog Box................................................................................... 18 Exercise 6 – Running Clash Sets................................................................................................................. 21 5 Interpreting the Clash Report ............................................................................................................... 23 5.1 Clash Report................................................................................................................................... 23 5.1.1 Clash Groups Report ............................................................................................................... 23 5.1.2 Clash Detail Report .................................................................................................................. 23 5.1.3 Filter Pane ................................................................................................................................ 23 5.2 Viewing the Clash Report.............................................................................................................. 24 5.3 Clash Detail..................................................................................................................................... 25 5.4 Displaying the Clash Group in PDMS .......................................................................................... 26 5.5 Clearing the Plant Design (PDMS) 3D Labels ............................................................................. 27 5.6 Clearing the Plant Design (PDMS) Display.................................................................................. 27 Exercise 7 – The Clash Report ..................................................................................................................... 27 6 Clash Allocation and Approval............................................................................................................. 28 6.1 Automatic Approval of Clashes.................................................................................................... 28 6.2 Manual Approval of Clashes......................................................................................................... 29 6.3 Clash Allocation ............................................................................................................................. 30 Exercise 8 – The Clash Approval ................................................................................................................. 31 7 Clash Report and Element Report Filters ........................................................................................... 32 7.1 Basic Filter option.......................................................................................................................... 32 7.2 Advanced Filter option .................................................................................................................. 34 Exercise 9 – Clash Report Filtering ............................................................................................................. 36

www.aveva.com 4

AVEVA Plant (12 Series) Clash Manager (User) TM-1221

www.aveva.com 5

CHAPTER 1

1 Introduction Clash Manager is used to group clashes together and allocate them to owning disciplines for investigation. Clashes can then be approved or reallocated to other disciplines with comments, for example a hole in a floor plate may be required so the Pipe to Floor Clash is reallocated from the Piping Department to the Structural Department. Clash Manager is not intended to replace good design practice using Plant Design (PDMS) it is intended to enhance clash management.

1.1

Aim

The following points need to be understood by the trainees •

1.2

Understand how Clash manager can be used to manage interference checking in Plant Design (PDMS).

Objectives

At the end of this training, you will have a • Broad view of Clash Management

1.3

Prerequisites

• •

1.4

There must also be a copy of SQL or ORACLE available for creating a Clash Manager ORACLE or SQL instance. The User should have knowledge of PDMS

Course Structure

Training will consist of oral and visual presentations, demonstrations and set exercises. Each workstation will have a training project, populated with model objects. This will be used by the trainees to practice their methods, and complete the set exercises.

1.5

Using this guide

Certain text styles are used to indicate special situations throughout this document, here is a summary; Information the user has to Key-in 'will be red' Annotation for trainees benefit:

L

Additional information Refer to other documentation

www.aveva.com 6

AVEVA Plant (12 Series) Clash Manager (User) TM-1221

www.aveva.com 7

CHAPTER 2

2 Clash Manager Login

2.1

Access to Clash Manager

Access to Clash Manager will be done from Aveva Plant Design (PDMS) so we first need to enter Aveva Plant Design (PDMS) in the project SAM. Starting PDMS Start > All Programs > AVEVA > Model Management 12.0 > Model Management PDMS

The Admin User Name is SYSTEM The SYSTEM Password is XXXXXX Select the /SAMPLE MDB Enter Design

2.1.1

Starting Clash Manager

Utilities > Clash Manager Start Up…

www.aveva.com 8

AVEVA Plant (12 Series) Clash Manager (User) TM-1221

At the Model Management Logon Screen Select CLASH_SAM in Project field and Click on Logon

L

Note once the windows user name has been added to Clash manager the login screen is not normally shown

The Main Clash Manager Screen is now displayed.

www.aveva.com 9

CHAPTER 3

3 Creating Clash Sets Clash Sets are groups of Plant Design (PDMS) items that are to be clash checked against other Plant Design (PDMS) items. Clash sets are used to organise the Plant Design (PDMS) items being checked into manageable sizes. Clash sets are based on discipline and area. It is assumed that you are familiar with normal clashing in Plant Design (PDMS). In Clash Set you define your Obstruction List, Exclusion List, Check List, Tolerance etc To create a Clash Set Select Tools > Clash Sets form the Clash Manager Main Menu.

L

Remember to be able to create a Clash Set you must be a ticked Administrator in Clash Manager Configuration > Security > Users

Initially there will be no clash sets. We will create a Clash Set that will allow us to check pipes in the TRAINPIPE zone against all items in zones TRAINPIPE and TRAINSTR under site TRAINSITE.

www.aveva.com 10

AVEVA Plant (12 Series) Clash Manager (User) TM-1221

3.1

Add a new Clash Set

Select the Add Button

Set a title TrainSet Set the MDS /SAMPLE

3.2

Setting the Obstruction List

A Obstruction list is a list of named elements covering a range of elements and their attributes from within the specified MDB that form the Obstruction list Select the obstruction list pane using the Right Hand Mouse Button.

Select Browse

www.aveva.com 11

AVEVA Plant (12 Series) Clash Manager (User) TM-1221

Using the AVEVA Plant Design (PDMS) Browser we could select any items to be in our obstruction list. As we wish lets select under Site /TRAINSITE Zone /TRAINPIPE and Click on Add Button. Select Zone /TRAINEQUI and Click on Add Button.

Dismiss the form

3.3

Setting the Check List

A Check list is a list of elements covering a range of elements and their attributes from within the specified MDB that form the ‘check list’ for clash detection Select the Browse PDMS Model button under the Check List

www.aveva.com 12

AVEVA Plant (12 Series) Clash Manager (User) TM-1221

Select the Zone /TRAINPIPE and click on Add button

Dismiss the form

3.4

Setting the exclusion List

The Exclusion List is list of AVEVA Plant Design (PDMS) items that will not be included in the Obstruction List. For this we are going to exclude a Equipment by using wild cards.

3.4.1

Adding Items - Wildcards

Regular Expression Summary Value Meaning ^ Matches the start of a line $ Matches the end of a line . Matches any character * Matches zero or more occurrences of the previous expression [string] Matches any one of the characters listed in string

In addition to the standard Regular Expression syntax there is a simple NOT operator . If the exclamation mark is the first character of the Regular Expression, the rule evaluates TRUE if the expression fails. If wildcards were entered at the 'Add to Check List' dialog box as necessary, check the wildcard expansion. Examples of Regular Expression Syntax Example Matches Expression ^[AB]305$ A string beginning with ‘A’ or ‘B’ and ending with ‘305’ [AB]305 A string containing ‘A’ or ‘B’ followed by ‘305’ !TEMP45 Any string that does NOT contain ‘TEMP45’ ^/S45/.*/TEMP45$ A string beginning /S45 and ending with TEMP45 !^/S45 Any string that does not begin with /S45

Result of Example Expression A305 or B305 IBMA305HAL or PQRB305LMN /THIS/string/Matches /S45/ABCanythinggoeshere345/TEMP 45

www.aveva.com 13

AVEVA Plant (12 Series) Clash Manager (User) TM-1221

We will now add some “exclusions” using wild cards. On the Exclude List Select Add

Click on OK button

Once you have used wild cards you can check that you are getting the results you require.

Use the Right Hand Mouse button on the Exclude List window Select Evaluate This will show the Expansion of the Exclusion List

www.aveva.com 14

AVEVA Plant (12 Series) Clash Manager (User) TM-1221

Using wildcards create the exclusion list that includes all the Equipments with 103 Click on Dismiss button Details of Clash Set Data form Extents tab Limits tab History tab Nocheck Within field "new" Tolerance field MAP Override checkbox

The items on this tab are used to specify the overlap, gap and clearances. The items on this tab are used to specify the co-ordinates of the space occupied by the clash set. The items on this tab show the dates and details of previous clash runs No clash checks between items within the same hierarchy of given Types A clash which is between the same two elements of an existing clash and is within this tolerance is not treated as new clash If checked, causes desclash to ignore errors in the Spatial Map, which would otherwise abort the desclash run.

Ignore Connections Ignore Connections at steelwork Junctions checkbox Branch Check radio group Used to select either 'A Check' or 'B Check'. The default is 'B Check'. For a complete explanation of 'A Check' and 'B check' see the DESIGN User Manual. Check ADD checkbox Passes the ‘Check ADD’ option to desclash. This causes the Clash Check List to be automatically added to the Obstruction List. Any existing contents of the Obstruction list are ignored. OK button Confirms selections made and closes dialog box Cancel button Ignores selections made and closes dialog box. When you are happy that the form is correct OK the form At this point you may wish to ensure the Spatial Map is up to date, go back to Plant Design (PDMS) Design and open a command window Display>Command Line… and type MAP BUILD NEW MDB and hit return (if you choose not to update the Spatial Map check the Map Override option). Whenever you update Plant Design (PDMS) you must remember to do a Savework.

www.aveva.com 15

AVEVA Plant (12 Series) Clash Manager (User) TM-1221

Exercise 1 – Clash Sets Create a Clash Set as described above to Clash check a Pipe Zone.

www.aveva.com 16

CHAPTER 4

4 Running a Clash Set This section discusses submitting clash runs.

4.1

Running Clash Sets

There are two ways of submitting a Clash set from the main Clash Manager Window Select Run > Clash Set > TrainSet

Alternatively you could select Tools > Clash Sets…

www.aveva.com 17

AVEVA Plant (12 Series) Clash Manager (User) TM-1221

Select the required Clash Set TrainSet and Run Desclash Button

4.1.1

Items on the Run Clash Set Dialog Box

Branch Check Type radio group

Used to select either 'A Check' or 'B Check' for this run. The default is set in the data associated with the Clash Set. 'A Check' does a full primitive by primitive check of every component within a branch. This option is not normally recommended. 'B Check' is a simplified check which ignores clashes between certain pairs of components within the branches. This option is normally used.

MAP Override checkbox

If checked, causes desclash to ignore errors in the Spatial Map, which would otherwise abort the desclash run. The default is given in the Clash Set data.

www.aveva.com 18

AVEVA Plant (12 Series) Clash Manager (User) TM-1221

Check ADD checkbox Passes the ‘Check ADD’ option to desclash. This causes the Clash Check List to be automatically added to the Obstruction List. Any existing contents of the Obstruction List are ignored. The default is given in the Clash Set data. Ignore Connections checkbox

Ignore Connections at steelwork Junctions. The default is given in the Clash Set data.

Clash Run Comments Displays the comments associated with the Clash Set data. field Progress bar and During the clash run, the bar graphically indicates the percentage adjacent indications progress. During the clash run, a 'Loading item number' message appears above the bar and is continually updated. During the clash run, continually updated numbers below the bar show 'Total clashes processed' and a 'Significant Elements'. During the clash run, a 'Heartbeat' at the bottom right-hand of the dialog box shows that the process is in operation. If the clash update cannot be completed, an error message appears. Run button

To initiate a clash run

Cancel button

To abort a clash run

As each item on the CheckList is processed by desclash, the data is loaded into the Clash Manager Database while at the same time desclash continues processing subsequent CheckList items. Select the Run Button

Once the Clash Run is completed the above dialog will get closed.

www.aveva.com 19

AVEVA Plant (12 Series) Clash Manager (User) TM-1221

Right mouse click on the above Clash Sets window and select Display Counts

In the above Clash Sets window, you can view total number of Clashes and Unapproved Clashes Select Dismiss Following the Clash Run a report will have been created and the Clash Manager Graph will have been updated to show the number of Clashes and if they are approved or not.

www.aveva.com 20

AVEVA Plant (12 Series) Clash Manager (User) TM-1221

Exercise 2 – Running Clash Sets Run your clash set that you created in the previous chapter

www.aveva.com 21

AVEVA Plant (12 Series) Clash Manager (User) TM-1221

www.aveva.com 22

CHAPTER 5

5 Interpreting the Clash Report Once a Clash set has been run a Clash report will be generated, this section discusses the clash run and describes how you display any clashes found.

5.1

Clash Report

Reports on clashes are presented in a separate window that includes a main menu with dropdown menus, a toolbar and a status bar. A popup menu is available for both reports. There are two types of report, namely, Clash Groups and Clash Detail. Both reports are in tabular format. The reports appear in separate panes, and either or both can be displayed. The pane that is 'Active' has a dark blue title bar; the 'Inactive' pane has a grey title bar. Scroll bars are available for access to data that overspills the panes. Details of the current filter can be displayed in a separate pane, titled Filter, at the bottom of the window.

5.1.1

Clash Groups Report

Each row of this report is dedicated to a clash group. The data in the columns is identified by the column headings. The width of a column can be set by double-clicking on the column heading. The width then toggles between that of the heading and that of the widest data item in the column The left-hand column shows the status of the group, as follows: GREEN tick Approved RED cross Unapproved BLUE question mark Pending GREEN tick superimposed on Conditionally Approved. BLUE question mark Fields in the report are colour-highlighted as follows: YELLOW Indicates the owner discipline, and if appropriate, highlights the element which belongs to the discipline RED UNALLOCATED discipline CYAN Change highlighting.

5.1.2

Clash Detail Report

Each row of this report is dedicated to an individual clash within the group(s) selected in the Clash Groups report. The structure of the report, column one indications and field colour-coding are as described for the Clash Groups report.

5.1.3

Filter Pane

This pane displays the filter criteria and values currently set to limit the data shown on clash reports. The information appears in a two-column table showing criteria in the left-hand column and values in the righthand column.

www.aveva.com 23

AVEVA Plant (12 Series) Clash Manager (User) TM-1221

5.2

Viewing the Clash Report

Select Tools > Clash Report > Display Report

Alternatively you can select the Clash Report Icon

www.aveva.com 24

AVEVA Plant (12 Series) Clash Manager (User) TM-1221

The Clash Report will be displayed: -

The above Report shows Clash Groups allocated to Piping and EQUI disciplines. One Clash Group is approved and the rest require investigation. The columns are as follows: Group Status Level Type Group Element 1 Discipline 1 Group Element 2 Discipline 2

5.3

Sequential Clash Group Number Approved, Unapproved, Pending, Conditional. HH, HS, HI, II, IS, SS TOU, CLA, CLE Name of PDMS Element 1 Discipline of PDMS Element 1 Name of PDMS Element 2 Discipline of PDMS Element 2

Clash Detail

Each Clash Group may have more than one clash in it. Select a Clash Group

The Clash Detail will be displayed in the bottom pane.

www.aveva.com 25

AVEVA Plant (12 Series) Clash Manager (User) TM-1221

5.4

Displaying the Clash Group in PDMS

If the Auto View Button is selected each time you click on a Clash Group You will be navigated to the Clash in PDMS.

Select the Auto View Button Select Clash Group

The Plant Design (PDMS) view above is of Clash Group in ISO3

www.aveva.com 26

AVEVA Plant (12 Series) Clash Manager (User) TM-1221

5.5

Clearing the Plant Design (PDMS) 3D Labels

Select the Clear 3D Labels Icon and the Plant Design (PDMS) labels will be removed from the display.

5.6

Clearing the Plant Design (PDMS) Display

Select the Clear 3D Display Icon and the Plant Design (PDMS) display will be cleared ready for the next clash display.

Exercise 3 – The Clash Report Work through the clash Groups and try to understand why each Clash Group has been created, Assigned and Automatically Approved.

www.aveva.com 27

CHAPTER 7

6 Clash Allocation and Approval It is not always possible to clear all the clashes in Plant Design (PDMS) sometimes it will be necessary to accept or approve a clash. Clash Manager gives you that ability. Once a clash has been approved it can be ignored in future clash runs. Following investigation it may be more appropriate to change the ownership of a clash to another discipline for fixing or clash approval.

6.1

Automatic Approval of Clashes

In the Clash report displayed, there are five clash groups, out of which one is automatically approved.

Rules can be set to automatically approve a clash by a administrator or Clash Coordinator. Select Tools > Settings > Clash Manager Configuration and then select Accept tab Details of setting up of rules is explained in Clash Manager Administration course

www.aveva.com 28

AVEVA Plant (12 Series) Clash Manager TM-1221

6.2

Manual Approval of Clashes

Clashes can also be manually approved, if the user has access rights to do it Access Clash Report by Selecting Tools > Clash Report > Display Report Select the Clash Record which has to be manually approved, Right mouse click and select the Approve option

The Status will change from Unknown to Approved

After approval the colour will change to make it visible

www.aveva.com 29

AVEVA Plant (12 Series) Clash Manager TM-1221

Rerun the same Clash Set, just to check that status of the clash which has been approved manually remains the same

There will be change in colour, so that user can make out that it has been manually approved.

6.3

Clash Allocation

Whilst investigating a clash it may become more appropriate to allocate the clash to the Group Element discipline for correction or approval. We can change the ownership of some Clash Groups to Group Element 2 or Group Element 1 Identify Clash Group Select Set Owner Element

www.aveva.com 30

AVEVA Plant (12 Series) Clash Manager TM-1221

Exercise 4 – The Clash Approval Work through the clash groups and manually approve a clash group and rerun the clash set and check the status of the clash.

www.aveva.com 31

CHAPTER 7

7 Clash Report and Element Report Filters By using the filter option, the user can restrict the data displayed on Clash and Element reports. When the filter form is used for Element report, the facilities are restricted and unavailable facilities are disabled or shaded out. In the filter form, there are two tabs one is Basic and another one is Advanced

7.1

Basic Filter option

In the Clash report displayed, there are five clash groups, out of which two are approved.

Now let’s display only the groups which are approved in Clash Report

In Clash Report displayed, select Tools > Set Filter or Click on Set Filter button on the tool bar

In the Filter form displayed, Uncheck the Unapproved, Conditional, Pending options and Check Enable filter option as shown

www.aveva.com 32

AVEVA Plant (12 Series) Clash Manager TM-1221

Click on OK button Only Approved Clashes are now displayed in the report

www.aveva.com 33

AVEVA Plant (12 Series) Clash Manager TM-1221

7.2

Advanced Filter option

In the Advanced filter option we can filter the report based on Automatic/Manual assignment of Status, Automatic/Manual assignment of Discipline, Priority, Class etc. In the Clash report displayed, there are two clash groups, out of which one is manually approved and another automatically approved.

Let’s filter the one which is manually approved In the Filter form displayed, Select Advanced tab, Check

www.aveva.com 34

AVEVA Plant (12 Series) Clash Manager TM-1221

Uncheck Automatically Set option in Status box

Click on OK button

Now only Clashes which have been manually approved are displayed in Clash Report

www.aveva.com 35

AVEVA Plant (12 Series) Clash Manager TM-1221

Exercise 5 – Clash Report Filtering Work through the clash groups and filter the desired data.