TI170&175&390&395 User Manual

November 3, 2017 | Author: Freddy Cuervo Camargo | Category: Battery Charger, Personal Computers, Infrared, Battery (Electricity), Secure Digital
Share Embed Donate


Short Description

Download TI170&175&390&395 User Manual...

Description

TI170/TI175/TI390/TI395 UFPA Infrared Camera User Manual Please read carefully before first use

ZHEJIANG ULIRVISION TECHNOLOGY CO., LTD

To Our Customer Dear Customer: Thank you for choosing TI Series Infrared Camera! Please read this user manual carefully before first use. Also please keep in a safe place for reference in the future. Please operate with the recommended instructions in user manual. We reserve the right to change this user manual without further notice. The copyright owner is Zhejiang ULIRvision Technology Co., LTD Sincerely, ULIRvision Technical Support

WARNING DO NOT OPEN OR EXCHANGE PARTS! REPAIR ONLY CAN BE CONDUCTED BY STUFF! NOTICE

z

In order not to cause malfunction or even damage the device please do not direct the lens towards strong high-temperature radiation source (such as the sun) whether the power is on or off!

z

Avoid violent shock and impact during operation or transport.

z

Storage temperature is between -40℃ and 60℃. The device must be kept in original packing case during transport.

z

Typical storage place is cool, dry, ventilated, and without strong electromagnetic field.

z

Keep the lens surface off grease or any chemical substance which would damage the lens. Close the lid after operation.

z

Please regularly backup data on PC to prevent potential data loss and format the internal FLASH memory duly to make it operate properly.

Table of Contents 1. 2.

3.

4.

5.

Product Summary.......................................................... 1 1.1 Standard Item List...................................................... 2 1.2 Optional Item List ....................................................... 2 Battery and Charger...................................................... 2 2.1 Charging Battery ........................................................ 3 2.2 Direct Charging .......................................................... 3 2.3 Attention for Using Battery Charger ........................ 3 Panel Function Summary ............................................ 3 3.1 Main Control Panel .................................................... 4 3.2 Side View .................................................................... 7 3.3 Bottom View................................................................ 8 3.3 Left Side View............................................................. 8 Quick Start Reference .................................................. 9 4.1 Battery Setting............................................................. 9 4.2 Quick Operations ....................................................... 9 4.3 Measure Target Temperature................................. 10 4.4 Infrared Image and Voice Annotation ................... 10 4.5 Infrared Image Playback ......................................... 10 4.6 Telephoto and Wide-angle lens ............................. 11 4.7 Connect to PC .......................................................... 12 4.8 Video and Audio output........................................... 12 Operation Menu............................................................ 13 5.1 Display Summary..................................................... 13 5.2 Main Menu ................................................................ 15 5.2.1 File ..................................................................... 16 Manage ........................................................... 16 Save ................................................................ 17 Record & Play ................................................ 17 Delete .............................................................. 18 Format............................................................. 18 5.2.2 Measure............................................................ 19 Spot Measure................................................. 20 Line Measure ................................................. 21 Horizontal Line Measure .......................... 21 Vertical Line Measure............................... 22 i

Vertical Line Measure.............................. 22 Area (Rect) Measure................................. 23 Parameters ................................................... 24 Emissivity.................................................... 25 Distance...................................................... 25 Adjust Ratio................................................ 25 Adjust Temp............................................... 25 Save Setting................................................... 26 5.2.3 Image ................................................................ 26 Image Setup................................................... 26 Alarm Switch .............................................. 27 Alarm Temp................................................ 27 Alarm Color ................................................ 27 Isotherm Color ........................................... 27 Isotherm Temp .......................................... 27 Hot Superposition...................................... 27 Thermal Superposition Attribute.............. 29 Fusion ......................................................... 29 Alarm Color ................................................ 32 Analysis Setup ............................................... 33 Temp Range .............................................. 33 IR Lens ....................................................... 33 Ambient Temp ........................................... 34 Reference................................................... 34 Ref Temp.................................................... 34 Image Reverse .............................................. 34 Clear Screen .................................................. 34 L&S (Auto/Manual Mode)............................. 34 5.2.4 Setup ................................................................. 34 System Setup................................................. 35 Language ................................................... 35 Auto Rectify................................................ 36 Auto Save................................................... 36 Video ........................................................... 36 Transparence............................................. 36 Display Device........................................... 36 Screen Save .............................................. 36 ii

Power Save................................................ 36 Storage Medium ........................................................ 37 Time & Date ................................................... 37 Factory Default .............................................. 37 System Information ....................................... 39 Disc Information............................................. 39 6. Building Thermal Imaging Summary ...................... 40 7. Technical Specifications............................................ 41 8. Technical Support ....................................................... 44

iii

Disclaimer Limited Warranty Each ULIRvision product is warranted to be free from defects in material and workmanship under normal use and service. This warranty extends only to the original buyer or end-user customer of an ULIRvision authorized reseller, and does not apply to fuses, disposable batteries, or to any product which, in ULIRvision’s opinion, has been misused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation or handling. ULIRvision warrants that product will operate substantially in accordance with its functional specifications. ULIRvision does not warrant that product will be error free or operate without interruption. ULIRvision’s warranty obligation is limited, at ULIRvision’s option, to refund of the purchased price, free of charge repair, or replacement of a defective product which is returned to an ULIRvision authorized service center within the warranty period. Quality Assurance The development and production of this product is qualified per ISO9001 standard.

THIS WARRANTY IS BUYER’S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. ULIRVISION SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY. © 2012 ULIRvision Technology Co. All rights reserved. iv

1. Product Summary The TI170/TI175/TI390/TI395 Infrared Camera (equipped with Uncooled Focal Plane Array Micro-bolometer) produces crisp thermal image and accurate temperature reading to help increase system maintenance quality and efficiency in many industries. TI170/TI175/TI390/TI395 Infrared Camera is packed with advance features, such as colored thermal images, multi-measurement methods, real-time video, voice annotation, sound and color alarm, IR fusion, Built-in flash and SD card storages.

Typical Application: z z z z z z

Power Industry: Monitor and diagnose the condition of electrical wire and equipment, detect power leak, and prevent system malfunction. Petrochemical Industry: oil pipeline check, material interface detect, heat leakage, insulation structure and power equipment detect. Fire Protection: forest fire protection and latent fire source search, self-ignition prevention and detection of special material, electric fire precaution detect. Medical Application: Accurately measure human body temperature and analyze temperature field distribution. Building Industry: humidity, air leakage and insulation defects detect. Other Applications: Civil engineering, scientific research, and railway etc

1

1.1 Standard Item List TI170/TI175/TI390/TI395 infrared camera comes with the following standard items and accessories: Name Infrared Camera Li-Ion Battery Charger SD Card SD Card Reader USB Cable Video Cable Converter cable User Manual Warranty Card IRSee Software CD Adapter Transport Case

Quantity 1 SET 2 PCS 1 PC 1 PC 1 PC 1 PC 1 PC 1 pc 1 PC 1 PC 1 PC 1 PC 1 PC

1.2 Optional Item List

z z

  Wide-angle lens   Telephoto lens

2.

Battery and Charger

It is recommended to charge battery immediately when device indicates low power, please read more about battery installation and removal methods on Page 8. Device comes with two sets of Li-Ion battery and one battery charger. It is strongly recommended to operate only with the included battery and charger. Use any other brand charger or Li-Ion battery may cause fire or critical damage. 2

2.1 Charging Battery Align the notch of the battery at the charger’s mount, press the battery downward gently along the triangular arrow, and fit it to the end. z Connect the charger to an AC outlet, during charging, the red LED will be on, and when charging is completed, the green LED will be on instead. : It is about 4 hour s to completely charge one battery.

z

2.2 Direct Charging It is available to charge the built-in battery with the adapter; it is about 5 hours to fully charge a run-out battery. The indicator indicates orange in charging and remains green when fully charged. 2.3 Attention for Using Battery Charger z z z z z z

3.

Battery Charging can only be conducted inside of a house. Do not short-circuit the battery. Do not put the battery in high temperature environment (≥60℃). Never disassemble the battery or put it into fire, which may cause explosion. Do not try to modify the battery or the charger. Li-Ion battery has no memory effect, charging can be conducted at any time. Please remove the charger from AD socket as soon as charging is completed.

Panel Function Summary

In this manual, “long press” means Long press button down for about 2 seconds, and “press” or “short press” means press and release.

3

3.1 Main Control Panel

1. Power LED Light After infrared camera is turned on, the indicator functions as a power indicator in green; functions as a charging indicator in orange, indicating the battery is being charged now.

2. HotKey button 1 Press to automatically focus, and Long press to turn on / off LED light. 3. HotKey button 2 Press to switch between measured objects (point, line and area), and fusion zone, setting range of thermal superposing temperature, color code, temperature upper and lower limits; and Long press to turn on / off the laser. 4

4, 5, 6,7 Direction buttons Up ( ), Down ( ), Left ( ), and Right ( ) keys have different usages in different modes. In main menu, direction buttons are used for moving selected items or changing slide-bar value. In real time Infrared view mode, directions buttons provide one-click access. In Fusion or Superpose imaging mode, press Right ( ) to make better overlaying between visual and infrared images. Press Left ( ) and Right ( ) to select preview images. Press Left ( ) to freeze Infrared image and press again to unfreeze. Press Up ( ), or Down ( ) to switch between normal view and 1-8x zoom continuous After press Hotkey button 2 in area measure(in yellow flashing) : z z

z

z

Select measured spots: press Up (

), Down (

), Left ( ),

and Right ( ) button to move the spot in the same direction. Select the measure line and sampling line; press Up ( ), Down ( ), Left ( ), and Right ( ) button to move the line in the same direction.

Select area box: in move menu, press Up ( ), Down ( ), Left ( ), and Right ( ) buttons to move area box, and in size menu, press Up ( ) and Down ( ) to resize the vertical direction area box, press Left ( ) and Right ( ) buttons to resize horizontal area box. Select Fusion area: in fusion imaging mode, press Up ( ), Down ( ), Left ( ), and Right ( ) buttons to move infrared image area at same direction; press Up ( ), Down ( ) buttons to resize vertical fusion area; and press Left ( ) and Right ( ) buttons to resize horizontal fusion area.

5

z

Select and set thermal superposing temperature range: in thermal superposing imaging mode, press Up ( ) and Down (

z

) buttons to select slide-bar, and press the Left ( ) and

Right ( ) keys to set the superposing temperature upper or lower limit, as well as the temperature values above or below the superposing temperature. Select Color Palette or temperature measurement limit: Press Left ( ) and Right ( ) to change Color Palette; and Press Up ( ) and Down ( ) buttons to change temperature limit.

8. (Menu / Enter) button This button has different functions under different conditions: 1).In real time Infrared view mode, press this button to open the main menu. 2).In the menu mode, press the key to confirm operation. 3).In real time Infrared view mode, long press this button to manually rectify measurement result, LCD screen will display the word “rectifying.” 4).In image viewing mode, long press this button to exit. :After auto rectifying, if device has abnormal noise, long press button to perform manual rectifying usually solves such issues. 9, 10, Manual Focus (T / W) button Press T/W button to manually focus to get better thermal image when auto-focus thermal image is not good enough. 11, 12, CW / CCW imaging mode switch Press the button to switch image models among infrared, visible, fusion, superpose, and picture in picture (P-I-P). 13. Shutter key Press the button to save the current image. 6

3.2 Side View

14. Power ON/OFF button Long press this button to power on/ off the device. 15. Multifunctional interface for audio output or video output Please insert converter cable. It can be connected to headphones to listen the playback audio notes as analog audio output interface; It can be connected to the monitor to play videos as a video output interface. 16. SD card interface MICRO 2G SD card can be inserted into the interface to expand storage volume. 17. USB Interface Standard USB interface can be connected to the computer for data transmission.

7

3.3 Bottom View

18. External DC In External DC requirement is DC 5V. 19. Screw nut on tripod Size of screw nut on tripod 1/4” _20. 3.3 Left Side View

20. 3.2" Color 270° tiltable LCD

8

4.

Quick Start Reference

4.1 Battery Setting Insert and move in the lithium battery as indicated direction, user can easily insert and move the battery.

Battery Installation

Battery Removal

4.2 Quick Operations z z z

Insert the battery correctly. Long press Power button until the LED light is on, and wait until system finishes initialization. Slide IR Lens lid down, point to target, and adjust focus to get crisp thermal image. 9

z

Long press the

button to rectify thermal image.

4.3 Measure Target Temperature z

z z

z

Point device to measurement target, and press HotKey button 1 to auto-focus. On the upper-right LCD corner, *=×× displays the spot measurement result. For better accuracy, long press button to perform manual rectify. Select Area (Rect) Measurement to measure max, min, and average temperature within a rectangle box. It is recommended to press button to freeze thermal image first, and then apply different and detailed analysis. Press button one more time to unfreeze. When measure result is outside standard temperature range, screen display changes to indicate either below or above temperature range. E.g.: TI175/TI395 is with -20 ~ 250 ℃, then the Camera Will Display> 250.0 ℃ or
View more...

Comments

Copyright ©2017 KUPDF Inc.
SUPPORT KUPDF