Please describe the DBS3900 equipment (hardware configuration, board position, cable connections). DBS3900 (Distributed Base Station 3900) DBS3900 is consist of BBU3900, RRU3606, ODU3601CE, accessories, cable and antenna system.
2.
Which is the board that can support transmissions interface and how many types of transmissions support? CMPT -FE electric -FE optic -E1
3.
Which board will provide the connection between BBU and RRU? HECM
4.
Please fill in which can be the power input for one BBU …….. .?How many amperes we need for one RRU?
+24V,-48V; 20 ampers for one RRU if we have APM, or 15 ampers if we have an indoor site 5.
What speed can support each transmission port?
-FE electric 10/100Mbits/s; -FE optic 10/100Mbits/s; -E1 2Mbits/s 6.
Which are the official scenarios regarding swap procedure?
Trebuie sa explice ceea ce le-a excplicat alex la training, in legatura cu pozitia RRUurilor, pe pilon, la baza pilonului sau pe shelter. Se va preciza si conexiunea pana la RRU, adica daca se vor pastra feederii existenti sau se vor folosi jumperi pana la combiner si de la combiner la antene. 7.
Please draw E1 cable connection.
8.
Please draw cable connection rules related to BTS swap
9.
Which is the power input for the APM30H and in which port we connect the alarm cable for outdoor sites? Do we have AC power inside the APM30?
220V sau 380V, and the alarms are connected on MON1 and MON0 Yes, we do have AC power inside APM. 10. When
we use DCDU equipment and which function it
has? We use DCDU when we install BBU in 19 inch rack and the DCDU provides -48V. 11. What
is mandatory to have before connecting optical fibers? Which is the color for single mode fiber, but for multi mode fiber?
SFP module is mandatory to have. Single mode fiber- yellow Multi mode fiber - orange
12. How
you differentiate one RRU for 410MHz from one which is for 450 MHz?
450Mhz is 450.A and 410Mhz is 450.D or 450.L (este diferentiat prin subbanda) 13. How
many external alarms can be provided by one BBU? Which are the names of the ports?
16 alarms on EXT_ALM1 and EXT_ALM0 14. Which
is the role of each RRU RF port? How many inputs and outputs have one combiner?
TX/RX - main RX – diversity
4 inputs, 2 outputs
15. The
VSWR alarm appears on transmission or reception side? What about RSSI value?
VSWR on transmission and RSSI on reception 16. If
on co-transmission the link from switch to the first BBU will come on FE0 port, which will be the transmission port for the second BBU?
FE1 17. If
the transmissions are on E1 we’ll use co-transmission anymore?
NO 18. Which
is the impedance for E1 cable? Please specify which is the size for grounding cable .
120 ohms, 6 mm for grounding cable 19. Please
specify the user name and password for Telnet or FTP connection to BBU.
System System 20. Which
is the BBU local IP address and mask? On which port you can make the connection?
IP:172.16.16.16 SNM:255.255.255.0 21. OMC
engineer informs you that on sector A you have VSWR alarm, which are the steps in solving this issue?
Verify the connectors and then verify the jumper. 22. OMC
engineer informs you that the second BBU can’t be reached, which will be your local verifications to clarify the position of this issue in the network transmissions?
First you need to ping the first BBU and then you should ping the gateway.
P.S. Raspunsurile nu sunt complete. Se vor detalia schemele in examen.
Thank you for interesting in our services. We are a non-profit group that run this website to share documents. We need your help to maintenance this website.