Polarization Gain (dBi) Electrical Tilt (continuously adjustable) Horizontal Beamwidth (º), -3dB Vertical Beamwidth (º), -3dB Front to Back Ratio (dB) 180º±30º total power Cross Polar Discrimination (dB) Boresight Sidelobe suppresssion (dB) First sidelobe above horizon First null ll (dB) Impedance (W) VSWR
B1, B2 1710-2170
16,5
16,7
2—10
2—10
65,2
60
8
7
>25
>25
>10
>10
17
17
Typ 18
Typ 20
< 1.5:1 > 30
Interband isolation (dB)
> 30
Max power per input (W) External RET
B1
50
Intraband isolation (dB)
Intermodulation IM3 (dBc)
B2
±45º
R1
< -150 300 AISG 2.0 / 3GPP Protocol
*All specications are subject to change without notice. Refer to TELNET for the most current information.
Input
18 x 7/16 female connectors
Position
Bottom, 3x6 (7/16)
Dimensions (mm), H x Ø
2230 + 300 x 450
Weight (Kg)
88
Max wind speed (Km/h)
200
Azimuth (Full antenna / Per Sector)
1 of 2
± 50º / ± 15º
www.telnet -ri.es
V150505
Radome
Fiber glass + polyester
End Caps
Stainless Steel
Screws and nuts
Stainless Steel
IEC 60068 -2-1: Cold
IEC 60068-2-32: Free Fall Test
IEC 60068 -2-2: Dry heat
IEC 60068-2-56: Damp Heat Steady State
IEC 60068 -2-6: Sine Vibration
IEC 60068-2-64: Random Vibration
IEC 60068 -2-14: Change of Temperature
IEC 60529: IP Code Test
IEC 60068 -2-18: Water (Handheld shower)
IEC 60695-2-1/2: Resistance to re
IEC 60068 -2-27: Shock Test
UNE-EN 60598-2-3: Resistance to wind
IEC 60068 -2-29: Bump Test
Particular Specication: Resistance to ice
IEC 60068 -2-30: Damp Heat Cyclic
Temperature Humidity Saline Fog IP specication
2 of 2
–33º C a 70º C 50º C, 98HR IEC68-2-52, severity 2 IP66, IEC 60529 (Feb 2001)