Tcb Lostinpar

July 11, 2018 | Author: krp857349 | Category: Components, Electrical Engineering, Technology, Computing And Information Technology
Share Embed Donate


Short Description

Otis TCB board list of installation parameters...

Description

OTIS

FIELD COMPONENT COMPONENT MANUAL

Part:

4 - AA3

No.:

GAA26800BA VIIIa

Vintage: 01 / 1

Central & East Europe Area

Software Data

Page:

1/1

TCB

Date:

4-Jul-2000

FOD BERLIN

List of Installation Parameters

TCB List of Installation Parame Parameters ters

 Authorization Date D1:

29-Feb-2000

Running on PCB:

GAA 26800 BA

Software Version:

GAA 30084 AAB

Document Revision : Date Date 20-Jun-2000

Auth or A. Gerwing / G. Priebe

Page Page 1 - 28

Comment Original Document

Copyright 2000, OTIS GmbH & Co. OHG Berlin. No part of this document may be copied or reproduced in any form or by any means without the prior writ ten consent of OTIS GmbH.

OTIS

FIELD COMPONENT COMPONENT MANUAL

Part:

4 - AA3

No.:

GAA26800BA VIIIa

Vintage: 01 / 1

Central & East Europe Area

Software Data

Page:

2/2

TCB

Date:

4-Jul-2000

FOD BERLIN

List of Installation Parameters

1 - SYSTEM No.

Symbol

Default

Purpos e and Range

0.

TOP

2

Top position: 1 (1) 31

1.

LOBBY

0

Lobby position: 0 (1) 31

2.

BOTTOM

0

Bottom position: 0 (1) 30

3.

CFT-P

255

Cafeteria Position: 0 (1) 31 > 31 Disabled

4.

OPERAT

1

Operation FCL/DCL/SAP FCL/DCL/SAPB: B: 0 FCL 1 DCL 2 SAPB 3 SAPB with Car Coming Light 4 FCL, delete both calls on arrival 5 FCL with single button

5.

EN-BSM

0

Enable Basement mode (for DCL: both Up- and Down Hall Calls at lobby): 0 Disabled 1 Enabled

6.

PI

4

Type of serial serial Position Indicator: 0 7/16 Segment 1 Multilight via RIB 2 7 Segment-PI and LM-PI via RIB 3 Brazilian 10-Segment 4 OTIS 2000: LCD and ELD 5 Australian Dot Matrix 6 Australian Dot Matrix and Direction Indicator

7.

PI-OPT

0

Vendor PI option 0 no option 1 returning to ground floor 2 overloaded 4 out of service 8 lift on firefighting service note: if more than one of the above options should be available then you must add the appropriate numbers (e.g. to select 1+4 you must program 5)

8.

ELD-fOPG

20

front door movement movement time: opening 0 (0.1) 10.0 s 0 = automatic (not yet implemented)

9.

ELD-fCLG

20

front door movement time: closing 0 (0.1) 10.0 s 0 = automatic (not yet implemented)

sin ce

OTIS

FIELD COMPONENT MANUAL

Part:

4 - AA3

No.:

GAA26800BA VIIIa

Vintage: 01 / 1

Central & East Europe Area

FOD BERLIN

Software Data

Page:

3/3

TCB

Date:

4-Jul-2000

List of Installation Parameters

1 - SYSTEM No.

Symbol

Default

Purpos e and Range

10.

ELD-rOPG

20

rear door movement t ime: opening 0 (0.1) 10.0 s 0 = automatic (not yet implemented)

11.

ELD-rCLG

20

rear door movement time: clos ing 0 (0.1) 10.0 s 0 = automatic (not yet implemented)

12.

ELD-LNG

5

set Language for ELD: 0 (1) 19 0=SwiGer, 1=SwiFra, 2=SwiIta, 4=Italy, 5=UK, 6=Spain, 8=Germany, 9=Austria, 10=Sweden, 12=Belgium, 13=Portugal, 14=Egypt, 16=SthAfrica, 17=Finland, 18=Arabia, 20=Moscow, 21=StPetrbrg, 22=not used, 24=Hungary, 25=Poland, 26=Czech,

sin ce

3=France, 7=Netherlnd, 11=Luxem, 15=Denmark 19=Kuweit, 23=AGB, 27=UKB

13.

ELD-Sym1

0

Enable Non-Smoking symbol: 0 Disabled 1 symbol is displayed

14.

ELD-DOOR

0

Select Type of Door Display: 0: 1 COP for 1 door or 2 COPs for 2 doors 1: only 1 COP for 2 doors

15.

ELD-MSG

0

Enables Customer Messages on ELD: 0 no customer messages are displayed 1 customer messages are enabled (use SETUP-ELD to define the texts)

16.

EN-SFR

0

Enable SFR (signal flicker): 0 Disabled 1 Enabled

17.

LR-T

20

Light Relay time (IO 0026, PX2:4): 0 (1) 255 s Note: LR-T is started after the car has become IDLE. As soon as LR-T has expired the LR output is activated and the ELD (CPI-11) is switched to Sleep-Mode.

18.

LR-MODE

0

Fan / Light Relay mode option (IO 0026, PX2:4): 0 LR pulls only when door closed (Light) 1 LR pulls even if door is opened (Fan)

19.

EN-HLC

0

Enable Hall Lanterns on car calls: 0 Disabled 1 HLC 2 HL also during closing 3 HLC and during door closing

20.

HDL-TYP

0

Hall Direction/Lantern Type for OTIS 2000 Hall Button Box (IOs 814ff, 846ff): 0 Direction Indicator 1 Hall Lantern

OTIS

FIELD COMPONENT MANUAL

Part:

4 - AA3

No.:

GAA26800BA VIIIa

Vintage: 01 / 1

Central & East Europe Area

FOD BERLIN

Software Data

Page:

4/4

TCB

Date:

4-Jul-2000

List of Installation Parameters

1 - SYSTEM No.

Symbol

Default

Purpos e and Range

21.

HL-SET

0

Hall Lantern/Gong Setup: 0 HL/G at same pins 1 HL/G at different pins (RS4A) 2 NAO Chime board

22.

CR-DIR

0

Correction Fast Run Preferred Direction: 0 Down 1 Up

23.

CR-DO

0

Door opening after Correction Run 0 no door opens 1 only front door opens 2 only rear door opens 3 both front and rear door will open

sin ce

note: this is intended for DO2000, because a new init run is performed after each INS 24.

EN-RR

0

Enable Reduced Run (RR): 0 Disabled 1 Enabled (short or medium run)

25.

ERO-TYP

0

Define ERO type 0 without limit 1 car stops at terminal landings (same as TCI-limit) 2 ERO-input disabled (for LCB_II version D2)

26.

REM-TYP

0

Type of installed REM 0 REM-II, REM-III, REM-SL 1 REM-G

27.

CPC-TYP

0

select use of CPC outputs: 0 car position contact 1 'car here' light 2 French SSM 3 Arrival Hall Lantern (AHL-2)

28.

N+2 WIRE

0

enable 3-wire buttons: 0 normal car and hall buttons 1 3-wire car buttons 2 3-wire hall buttons 3 3-wire car and hall buttons

29.

DFCR-DEL

0

Delay for DFC-Relay 0 disabled 1 (1) 255 s delay for which DFCR output is kept active after DFC input has been opened Note:

For Module BDC

 AA A

OTIS

FIELD COMPONENT MANUAL

Part:

4 - AA3

No.:

GAA26800BA VIIIa

Vintage: 01 / 1

Central & East Europe Area

FOD BERLIN

Software Data

Page:

5/5

TCB

Date:

4-Jul-2000

List of Installation Parameters

2 - OCSS No.

Symbol

Default

Purpos e and Range

0.

CPR-T

20

Car Call Preference: 0 (0.1) 25.5 s

1.

 ARD-P

255

 Au tomatic Return Device Posi ti on: 0 (1) 31 > 31 Disabled

2.

 ARD-T

0

Set Delay for ARD (Automatic Return Device) mode: 0 (10) 2550 s

3.

 ARB L-T

0

Delay for Aut omatic Return To Bottom Landing 0 (10) 2550 s

4.

 ARB L-PRK

0

 ARB L park opti on 0 stay at bottom after ARBL has been performed 1 return to previous park landing after ARBL has been performed

5.

CTL/PKS

0

Select CTL or PKS swi tch: 0 IO 0010 is CTL input 1 IO 0010 is PKS input

6.

PKS-P

255

Parking Service Positio n: 0 (1) 31 > 31 Disabled

7.

PKS -TYP

0

Parking Shutoff Type: 0 ETO 1 NAO 2 ETO with door open after shutdown

8.

PKS-T

0

Parking Shutoff Time: 0 (1) 255 s

9.

PKS-DO

0

PKS default door: 0 Both doors will open at PKS-P 1 Only front door opens 2 Only rear door opens

10.

EN-SHB

0

Enable Separate Hall Buttons: 0 Normal HB-operation 1 Rear HB as Separate Riser

11.

DCP-T

50

Time until DCP-mode (delayed car protection): 25 (1) 255 s

12.

CTL-DO

0

CTL default door (car to any landing): 0 Both doors will open at CTL-P 1 Only front door opens 2 Only rear door opens

13.

CTL-P

255

CTL (Car To Any Landing) position: 0 (1) 31 > 31 Disabled

sin ce

OTIS

FIELD COMPONENT MANUAL

Part:

4 - AA3

No.:

GAA26800BA VIIIa

Vintage: 01 / 1

Central & East Europe Area

Software Data

Page:

6/6

TCB

Date:

4-Jul-2000

FOD BERLIN

List of Installation Parameters

2 - OCSS No.

Symbol

Default

Purpos e and Range

14.

 ANS

0

 ANS (anti nuis ance servi ce): 0 Disabled >0 Number of calls to trigger ANS

15.

 ATT

0

 ATT (Att endant Servic e) type: 0 Start with DCB or RDCB 1 Start with ATTU or ATTD 2 NAO (USA)

16.

ISC

0

Independent 0 1 2 3 4

17.

ISPS-TYP

0

Independent Servic e Park Swit ch (IO 638) 0 car calls allowed when ISPS active 1 no car calls allowed when ISPS active

18.

ISC-T

0

Independent Service Close Timeout 0 (1) 30 s max door open time when FPD is installed

19.

SPEECH

0

Speech Mode: 0 Floor message on CC only 1 Floor message also on HC

20.

CPMT-D

0

Car Position Message Trigger for Vendor type PI 0 (0.1) 25.5 sec

21.

DCMT-A

0

Door Clos e Message Trigger for Vendor type PI 0 (0.1) 25.5 sec

22.

DOMT-O

0

Door Open Message Trigger Optio n for Vendor type PI 0 trigger on opening and reopen 1 trigger on opening only

23.

DOC

0

Door Reopen Count: 0 No limit 1 (1) 255 Number of allowed door reopenings

24.

DS-CCB

0

Disable CCs behind movin g car: 0 CCs behind allowed 1 CCs behind not allowed

25.

DS-DOB

0

Disable DOB but ton: 0 DOB/RDOB always enabled 1 DOB disabled if door closed 2 RDOB disabled if door closed 3 Both disabled if door closed

Service: Start on constant pressure of CCB Start on constant pressure of DCB Start on ISD/ISU NAO (USA) Start on momentary pressure of CCB

sin ce

OTIS

FIELD COMPONENT MANUAL

Part:

4 - AA3

No.:

GAA26800BA VIIIa

Vintage: 01 / 1

Central & East Europe Area

FOD BERLIN

Software Data

Page:

7/7

TCB

Date:

4-Jul-2000

List of Installation Parameters

2 - OCSS No.

Symbol

Default

Purpos e and Range

26.

EN-RB

0

Enable car call Reset Button (IO 627, 725) 1 enabled in ATT mode 2 enabled in CHC mode 4 enabled in EFS mode 8 enabled in ISC mode note: if more than one of the above options should be available then you must add the appropriate numbers (e.g. to select 1+4 you must program 5)

27.

DHB-TYP

0

Enable DoorHoldButton for CARGO 2000 (IOs 620,628) DHB doortime can be canceled by... 0 press DCB or any CCB 1 press DCB or any CCB, or press DHB again (in this case the DHB-T is a 10-sec-timer!)

28.

PARK-1

255

Park Clock Position 1: 0 (1) 31 > 31 Disabled

29.

PARK-2

255

Park Clock Position 2: 0 (1) 31 > 31 Disabled

30.

PARK-3

255

Park Clock Position 3: 0 (1) 31 > 31 Disabled

31.

PARK-4

255

Park Clock Position 4: 0 (1) 31 > 31 Disabled

32.

PARK-5

255

Park Clock Position 5: 0 (1) 31 > 31 Disabled

33.

PARK-6

255

Park Clock Position 6: 0 (1) 31 > 31 Disabled

34.

PARK-7

255

Park Clock Position 7: 0 (1) 31 > 31 Disabled

35.

PARK-8

255

Park Clock Position 8: 0 (1) 31 > 31 Disabled

sin ce

OTIS

FIELD COMPONENT MANUAL

Part:

4 - AA3

No.:

GAA26800BA VIIIa

Vintage: 01 / 1

Central & East Europe Area

FOD BERLIN

Software Data

Page:

8/8

TCB

Date:

4-Jul-2000

List of Installation Parameters

3 - GROUP No.

Symbol

Default

Purpos e and Range

sin ce

0.

GRP-NO

1

Car identifier in gr oup: 1 (1) 3

1.

GROUP

1

Number of cars in group: 1 (1) 3

2.

CNL

1

Cars parking in Lobby: 1 (1) 3

3.

MIT-ST

0

MIT (Moderate incomming traffic) Startdelay: 0 (1) 255 s

4.

MIT-T

0

MIT Time-Out: 0 (1) 255 s

5.

MIT-VD

0

MIT Variable Interval Dispatch : 0 (1) 255 s

6.

MIT-DOOR

0

MIT Default Door 0 open door if car is not selected 1 keep door closed if car is not selected

7.

MIT-NLB

0

MIT No Lobby Bypass 0 Answer hall calls 1 Don’t answer hall calls

8.

DUPK-P

255

Dual Up Peak Border Position: 0 (1) 31 > 31 Disabled

9.

DUPK-G

0

Dual Up Peak Group : 0 Car belongs to subgroup 1 1 Car belongs to subgroup 2

10.

MOT-T

0

MOT (Moderate Outgoin g tr affic ) Time-Out: 0 (1) 255 s

11.

EN-UCB

0

Enable Up Call Bypass: 0 Disabled 1 Enabled

12.

TFS-P

255

Transfer Floor Positi on: 0 (1) 31 > 31 Disabled

13.

EN-ZBS

0

Enable separate basement zone: 0 No free car parks in basement zone 1 A free car parks in basement zone

14.

SEL-COMP

0

Select MCS310 Compatible Commun icati on 0 Triplex - Ring ICD 3.3; Group consists of MCS120 / 220 / 220M 1 Duplex - Ring ICD 3.0 (MCS310 with G44) 2 Duplex - Ring ICD 3.3 (MCS310 with G57)

15.

L-PARK

0

Lobb y Park Option (only if SEL-COMP 0 Disabled 1 Enabled

0)

OTIS

FIELD COMPONENT MANUAL

Part:

4 - AA3

No.:

GAA26800BA VIIIa

Vintage: 01 / 1

Central & East Europe Area

FOD BERLIN

Software Data

Page:

9/9

TCB

Date:

4-Jul-2000

List of Installation Parameters

3 - GROUP No.

Symbol

Default

Purpos e and Range

16.

PRKDST

0

Minimum Distance to park target to do park run 0 (1) 31

17.

EN-GSS

0

Group Successive Starting 0 disabled 1 GSS triggered by remote I/Os GSSI (972), GSSO (973) for multiple simplex cars 2 GSS triggered by serial group communication Note: during EPO only

18.

MG-DEL

0

Motor Generator Delay fo r GSS 0 (1) 255 s note: this delay depends on the duration of the acceleration phase Note: during EPO only

sin ce

OTIS

FIELD COMPONENT MANUAL

Part:

4 - AA3

No.:

GAA26800BA VIIIa

Vintage: 01 / 1

Central & East Europe Area

Software Data

Page:

10 / 10

TCB

Date:

4-Jul-2000

FOD BERLIN

List of Installation Parameters

4 - DRIVE No.

Symbol

Default

Purpos e and Range

sin ce

0.

DRV-TYP

0

Drive Type: 0

 AA A OVF20

1.

EN-ADO

0

Enable Advanced Door Opening 0 disabled (XADO) 1 enabled (ADO)

2.

1AT

5

1A Time: 0 (0.1) 25.5 s

3.

2AT

5

2A Time: 0 (0.1) 25.5 s

4.

DDP

32

DDP Time (fast r un): 0 (1) 45 s Note: This parameter is ignored for VF drives. A fixed value of ‘255’ is used instead.

5.

3P

32

3P Time (slow run): 0 (1) 45 s Note: This parameter is ignored for VF drives. A fixed value of ‘255’ is used instead.

6.

SPEED

100

Speed (fast ru n mode): 25 40 63 100 160 175 250 cm/s

7.

EN-MPD

0

Enable Motor Protection Device: 0 Disabled 1 MPD-3 (immediate stop) 2 MPD-1, MPD-2 (run to target)

8.

MPD-T

10

Motor Protection Device Time: 0 (1) 254 s 255 wait forever

9.

HY-TYP

0

Hydro Drive Type for Hydro: 0 Star - Delta 1 Soft 2 Direct 3 LSCH-2

10.

L-T

10

Set Star/Soft Time for Hydro: 0 (0.1) 25.5 s

11.

UX-D

20

Set Star/Delta gap / add. Soft Time (L+UX) for Hydr o: 0.06 (0.004) 1.020 s

12.

UXT-D

0

Set delay between UX and UXT for Hydr o: (contract option) 0 (0.1) 1 s

 AA A

OTIS

FIELD COMPONENT MANUAL

Part:

4 - AA3

No.:

GAA26800BA VIIIa

Vintage: 01 / 1

Central & East Europe Area

FOD BERLIN

Software Data

Page:

11 / 11

TCB

Date:

4-Jul-2000

List of Installation Parameters

4 - DRIVE No.

Symbol

Default

Purpos e and Range

13.

EN-PLS

0

Enable PLS1 (Oil Max-Pressur e Limit Swit ch) for Hydro: 0 Disabled 1 Enabled

14.

EN-OTS

0

Enable OTS (Oil Over Temperature Swit ch) fo r Hydro : 0 Disabled 1 stop at next target 2 immediate stop for AHVS

15.

 ACD/UXT

0

Select ACD or UXT output for Hydro: 0 ACD and UXT disabled 1 ACD enabled 2 UXT enabled (contract option)

16.

P-OFF-D

0

Set Power Off d elay for L SVF-W 0, 255 Disabled 1 (1) 254 s

17.

P-ON-D

10

Set Power On delay f or L SVF-W 8 (1) 20 s

sin ce

OTIS

FIELD COMPONENT MANUAL

Part:

4 - AA3

No.:

GAA26800BA VIIIa

Vintage: 01 / 1

Central & East Europe Area

FOD BERLIN

Software Data

Page:

12 / 12

TCB

Date:

4-Jul-2000

List of Installation Parameters

5 - DOORS No.

Symbol

Default

Purpose and Range

sin ce

0.

DOOR

2

Type of Doors: 0 FLH 1 9550T & ACG 2 9550T & TLD 3 OVL/MRDS & ACG 4 OVL & TLD/CLD 5 DCSS-4 without TRO 6 MCG 7 Kiekert / MLI & ACG without TRO 8 Kiekert / MLI & TLD/CLD without TRO 9 OVL-Penang & ACG 10 OVL-Penang & CLD/TLD 11 GENERIC (see parameters below) 12 DCSS-5

 AAB

Type of Doors: 0 FLH 1 9550T & ACG 2 9550T & TLD 3 OVL/MRDS & ACG 4 OVL & TLD/CLD 5 DCSS –4 without TRO 6 MCG 7 Kiekert / MLI & ACG without TRO 8 Kiekert / MLI & TLD/CLD without TRO 9 OVL-Penang & ACG 10 OVL-Penang & CLD/TLD 11 GENERIC (see parameters below) 12 DCSS-5

 AAB

1.

REAR

2

2.

EN-DDO

0

Enable DDO (double door o peration): 0 Disabled 1 double door on car call and on hall call 2 double door on car call, selected door on hall call

3.

EN-ADM

0

 Al ternating Door Mode 0 doors can open simultaneously 1 ADM preference to front door 2 ADM preference to rear door 

4.

F:DO-TYP

0

type of DO handling 00 DO never pulled 01 DO pulled when car door fully opened 10 DO pulled during opening 11 DO pulled when car door opening and also when fully opened note: only applicable if DOOR=11

OTIS

FIELD COMPONENT MANUAL

Part:

4 - AA3

No.:

GAA26800BA VIIIa

Vintage: 01 / 1

Central & East Europe Area

FOD BERLIN

Software Data

Page:

13 / 13

TCB

Date:

4-Jul-2000

List of Installation Parameters

5 - DOORS No.

Symbol

Default

Purpose and Range

5.

F:DC-TYP

0

type of DC handling 00 DC never pulled 01 DC pulled when car door fully closed 10 DC pulled during closing 11 DC pulled when car door closing and also when fully closed note: only applicable if DOOR=11

6.

F:EN-ACG

0

enable DW input for ACG 0 automatic hoistway doors 1 manual hoistway doors note: only applicable if DOOR=11

7.

F:EN-DCL

0

enable DCL input at IO 694 0 no DCL switch 1 DCL at IO no. 694 note: only applicable if DOOR=11

8.

F:DOL-D

0

automatic DOL si mulation 0 DOL at IO no. 0000 0.1 (0.1) 25.5s DOL is simulated after specified time if no DOL exists note: only applicable if DOOR=11

9.

R:DO-TYP

0

type of RDO handling 00 RDO never pulled 01 RDO pulled when car door fully opened 10 RDO pulled during opening 11 RDO pulled when car door opening and also when fully opened note: only applicable if REAR=11

10.

R:DC-TYP

0

type of RDC handling 00 RDC never pulled 01 RDC pulled when car door fully closed 10 RDC pulled during closing 11 RDC pulled when car door closing and also when fully closed note: only applicable if REAR=11

11.

R:EN-ACG

0

enable DW input for ACG 0 automatic rear hoistway doors 1 manual rear hoistway doors note: only applicable if REAR=11

12.

R:EN-DCL

0

enable RDCL input at IO 695 0 no RDCL switch 1 RDCL at IO no. 695 note: only applicable if REAR=11

sin ce

OTIS

FIELD COMPONENT MANUAL

Part:

4 - AA3

No.:

GAA26800BA VIIIa

Vintage: 01 / 1

Central & East Europe Area

FOD BERLIN

Software Data

Page:

14 / 14

TCB

Date:

4-Jul-2000

List of Installation Parameters

5 - DOORS No.

Symbol

Default

Purpose and Range

13.

R:DOL-D

0

automatic RDOL s imulation 0 RDOL at IO no. 544 0.1 (0.1) 25.5s RDOL is simulated after specified time if no RDOL exists note: only applicable if REAR=11

14.

15.

CM-TYP

CM-PROT

0

0

type of CMR handling 00 no CMR 01 CMR is pulled when car door is fully closed 02 CMR is pulled when car door is fully closed and a demand is present 03 CMR is pulled when car door is fully closed and the delay CM-D has expired 11 CMR is pulled when car door is closing and also when car door is fully closed 21 CMR is pulled when car door is closing and delay CM-D has expired note:

ACG-2: CMR can only pull if DW is active (i.e. landing door is closed)

note:

only applicable if DOOR=11 or REAR=11

max. ON-time of CMR when car st ops i n ERO 0 CMR not pulled 10 (10) 2540 s CMR drops after specified time (CMR pulls again when moving or switched to NOR) 255 no protection: CMR is always pulled during ERO note: only applicable if DOOR=11 or REAR=11

16.

DO-D

0

delay between CMR and DO 0 (0.1) 25.5 s DO is delayed for the specified time after CM has been dropped note: only applicable if DOOR=11 or REAR=11

17.

CM-D

0

delay between door m ovement and CM a) CM-TYP = 02, 03 0..255 CM pulls 0..25.5s after car door has fully closed b) CM-TYP = 21 0..255 CM pulls 0..25.5s after car door has started to close (if no DCL exists) note: only applicable if DOOR=11 or REAR=11

sin ce

OTIS

FIELD COMPONENT MANUAL

Part:

4 - AA3

No.:

GAA26800BA VIIIa

Vintage: 01 / 1

Central & East Europe Area

FOD BERLIN

Software Data

Page:

15 / 15

TCB

Date:

4-Jul-2000

List of Installation Parameters

5 - DOORS No.

Symbol

Default

Purpose and Range

18.

TRO-TYP

0

enable TRO outpu t 0 no TRO output 1 TRO at P6:5 for DO2000 (no DC allowed!) 2 TRO at P6:7 for MLI / Kiekert-2 (no DO allowed!) 3 TRO at P6:5 for AT20 (no DC allowed!)

19.

SEL-CMR

0

note:

only applicable if DOOR=11 and DO-TYP=0 resp. DC-TYP=0

note:

cut jumper J1 on LCBII !

select separate CM relay output (MCS220M) 0 (one door) CMR at RDC-output (P6:10) 1 (two doors) CMR at RSL (IO no. 785) NOTE: only applicable for FLH, MCG, ACG

20.

CMR-ES

0

CMR handling during Emergency Stop 0 drop CMR during ESR 1 keep CMR pulled during ESR

21.

TCI-TYP

0

type of CMR handling during TCI 0 CMR pulls only when TCIB is operated 1 CMR pulls always for CARGO2000 (100% ED required!)

22.

LDR

0

Limited Door Reversal: 0 Full DOB, full EDP, full LRD 1 Full DOB, limited EDP, full LRD

23.

EN-PMO

0

Enable PMO (door time monitoring): 0 Disabled 1 Enabled

24.

EN-NDG

0

Enable NDG (nudgin g): 0 Disabled 1 Enabled

25.

NDG-T

20

Nudging Time: 0 (1) 255 s

26.

EN-CK

0

Enable Cancel Doortime with CCB: 0 disabled 1 enable CK 2 enable CBC 3 enable CK and CBC note:

CK = cancel doortime with car button CBC = cancel car call with car button (press twice)

27.

DW-DLY

10

Debouncing Time of Door Contact DW: 0 (0.1) 25.5 s

28.

DO-BEL

0

Open Door Bell Timer: 0 (0.1) 25.5 s

sin ce

OTIS

FIELD COMPONENT MANUAL

Part:

4 - AA3

No.:

GAA26800BA VIIIa

Vintage: 01 / 1

Central & East Europe Area

FOD BERLIN

Software Data

Page:

16 / 16

TCB

Date:

4-Jul-2000

List of Installation Parameters

5 - DOORS No.

Symbol

Default

Purpose and Range

29.

MIN-C

20

Min Doortime Car: 0 (0.1) 25.5 s

30.

MAX-C

40

Max Doort ime Car: 0 (0.1) 25.5 s

31.

MIN-H

40

Min Doortime Hall: 0 (0.1) 25.5 s

32.

MAX-H

60

Max Doortime Hall: 0 (0.1) 25.5 s

33.

DOR-T

0

Door reverse time: 0 (0.004) 1 s

34.

RDOR-T

0

Rear door reverse time: 0 (0.004) 1 s

35.

DTC-T

20

Door Close Protection Time: 10 (1) 254 s DTC-time 255 Disabled

36.

DTO-T

20

Door Open Protection Time: 10 (1) 254 s DTO-time 255 Disabled

37.

LOB-NT

40

Lobby Door Time: 0 (0.1) 25.5 s

38.

CFT-NT

40

Cafeteria Door Tim e: 0 (0.1) 25.5 s

39.

SPB-NT

0

Special DOB Door Time: 0 (0.1) 25.5 s

40.

DHB-T

120

DHB Doortime: 0 (1) 255 s 0 (10) 2550s

for DHB-TYP=0 (see 2-OCSS) for DHB-TYP=1 (see 2-OCSS)

41.

WCO-T

0

Wild Car Door Time: 0 (0.1) 25.5 s

42.

SHO-T

0

Shabat Door Time: 0 (0.1) 25.5 s

43.

SHO-LT

0

Shabat Lobby Door Time: 0 (0.1) 25.5 s

44.

DAR-T

60

MPD/Hydro Door Open Time: 0 (1) 255 s

45.

DXT-T

0

DXT Time (extended d oor t ime): 0 (0.1) 25.5 s

sin ce

OTIS

FIELD COMPONENT MANUAL

Part:

4 - AA3

No.:

GAA26800BA VIIIa

Vintage: 01 / 1

Central & East Europe Area

Software Data

Page:

17 / 17

TCB

Date:

4-Jul-2000

FOD BERLIN

List of Installation Parameters

6 - POSITION REFERENCE No.

Symbol

Default

Purpos e and Range

sin ce

0.

LV-MOD

2

Leveling Mode: 0 DZ-STP stop with DZ: use DZ-DLY

(in 4ms units)

1 LV-STP

stop with LVU/LVD (for CARGO 2000): for CA-MOD=1 DZ at P1:6, LV at P1:11 (LV-U-D, LV-D-D not applicable)

2 DZ-STP

stop with DZ, 1LV/2LV: use LV-U-D, LV-D-D

(in 4ms units)

3 IP-STP

stop with IPU, IPD: (for 1-Speed Drive) (LV-U-D, LV-D-D not applicable)

4 UIS/DIS

stop with UIS, DIS: (for Hydraulic Drive) use LV-U-D for DIS (in 4 ms units) use LV-D-D for UIS (in 4 ms units)

Note: this parameter is ignored for: - Gamma S/D, Spec_60 and Dynalift - LSVF-W, OVF20 1.

DZ-TYP

0

DZ coding: 0 DZ = 1LV 1 DZ = 1LV and 2LV 2 POSY operation (if neither RLV nor ADO) to stop: DZ = 1LV and 2LV after stop: DZ = 1LV or 2LV Note: this parameter is ignored for: - OVF10 (DZ=P1:6) - CARGO2000 (DZ=P1:6, LV=P1:11)

2.

CA-MOD

0

CARGO mode: 0 no CARGO mode 1 CARGO 2000 (MCS120,MCS220) (uses DZ at P1:6, LV at P1:11)

3.

DZ-DLY

0

Delay for DZ: 0 (0.004) 1 s

(LV-MOD = 0)

4.

LV-U-D

12

Delay for DZ, 1LV/2LV (in u p di rectio n): 0 (0.004) 1 s (LV-MOD = 2, 4)

5.

LV-D-D

12

Delay for DZ, 1LV/2LV (in do wn direct ion): 0 (0.004) 1 s (LV-MOD = 2, 4)

6.

T-BASE

0

Time b ase fo r IPU-D, IPD-D, 1LS-D and 2LS-D: 0 0.1 s 1 0.004 s

7.

IPU-D

0

Delay for IPU: 0 (0.1) 25.5 s 0 (0.004) 1 s

(if T-BASE=0) (if T-BASE=1)

OTIS

FIELD COMPONENT MANUAL

Part:

4 - AA3

No.:

GAA26800BA VIIIa

Vintage: 01 / 1

Central & East Europe Area

Software Data

Page:

18 / 18

TCB

Date:

4-Jul-2000

FOD BERLIN

List of Installation Parameters

6 - POSITION REFERENCE No.

Symbol

Default

Purpos e and Range

8.

IPD-D

0

Delay for IPD: 0 (0.1) 25.5 s 0 (0.004) 1 s

(if T-BASE=0) (if T-BASE=1)

Delay for 1LS: 0 (0.1) 25.5 s 0 (0.004) 1 s

(if T-BASE=0) (if T-BASE=1)

Delay for 2LS: 0 (0.1) 25.5 s 0 (0.004) 1 s

(if T-BASE=0) (if T-BASE=1)

9.

10.

1LS-D

2LS-D

0

0

11.

EN-RLV

0

Enable RLV operation: 0 Disabled 1 Enabled

12.

RLV-TYP

0

RLV - Type: 0 1

RLV Relevelling DRLV Delayed Relevelling (using DIS1)

13.

RL-CNT

3

Limit of RLV steps: 0 (1) 255

14.

RL-DIS

255

Set RLV time up (DIS lost): 0 (0.1) 25.5 s

15.

RL-UIS

255

Set RLV tim e down (UIS lost ): 0 (0.1) 25.5 s 0 (0.004) 1 s (hydraulic drive)

16.

RL-U-D

0

Set RLV delay up: 0 (0.004) 1 s

17.

RL-D-D

0

Set RLV delay down: 0 (0.004) 1 s

sin ce

OTIS

FIELD COMPONENT MANUAL

Part:

4 - AA3

No.:

GAA26800BA VIIIa

Vintage: 01 / 1

Central & East Europe Area

FOD BERLIN

Software Data

Page:

19 / 19

TCB

Date:

4-Jul-2000

List of Installation Parameters

7 – Service No.

Symbol

Default

Purpos e and Range

sin ce

0.

Encoder

17

Pulse Width of Speed Encoder for SPB 0 (1) 63 mm

 AA A

Distance between two rising edges of the tension device. 1.

SDI-Dir

0

Direction of Speed and Direction Indicator 0,1

 AA A

Use this parameter to invert the display of the SDI 2.

SDI-Max

30

Maximum s peed value of SDI 0 (0.01) 0.63 m/s

 AA A

Speed at which all 8 LEDs of the Speed/Direction-Indicator are switched on. If during manual rescue operation the measured car speed is higher than this value, the LEDs are blinking and the buzzer is turned on. 3.

Spe-Rng

20

SPB Contract Speed Tolerance Range 0 (0.01) 0.5 m/s

 AA A

The LED CON-SPE is switched on if the measured car speed is in the range SPEED +/- SPE-RNG 4.

BRE-Max

10

Maximum speed for Brake Release Electrical 0 (0.01) 0.30 m/s

 AA A

Manual rescue operation: SPB drops the brake if the measured car speed is higher than BRE-MAX. 5.

BRE-Min

7

Minimum speed for Brake Release Electrical 0 (0.01) 0.29 m/s

 AA A

Manual rescue operation: SPB is pulls the brake again if the car speed has become lower than BRE-MIN. 6.

BRE-Hold

10

Reduce Power for B rake Release Electr ical 0 (0.01) 0.63 m/s

 AA A

Manual rescue operation: The power for the BRE device is reduced after the measured car speed has reached BRE-Hold. 7.

BRE-Tout

5

Timeout for Brake Release Electrical 0 (0.1) 0.5 sec

 AA A

Manual rescue operation: The brake is dropped if no speed is detected after BRE-TOUT. 8.

SPB-Temp

60

Temperature Limit for Service Panel Board 0 (1) 63 degrees Celsius HTS is activated if the SPB detects a temperature which is higher than SPB-TEMP.

 AA A

OTIS

FIELD COMPONENT MANUAL

Part:

4 - AA3

No.:

GAA26800BA VIIIa

Vintage: 01 / 1

Central & East Europe Area

FOD BERLIN

Software Data

Page:

20 / 20

TCB

Date:

4-Jul-2000

List of Installation Parameters

8 – EMERGENCY No.

Symbol

Default

Purpos e and Range

0.

ES-TYP

0

Define ES-Type: 0 ESS connected 1 ESB connected (closed door will remain closed) 2 ESB connected (closed door will open)

1.

ES-LRCU

0

define ES with LRCU check (IOs 964, 965, 966) 0-4 disabled else time for LRCU selftest

2.

ES-SLOW

0

enable slow recover run after ES 0 never (always start fast) 1 start slow after /ES during deceleration note: only applicable for OVF10, LSVF-W, OVF20

3.

EFO-P

255

EFO (emergency fireman operation) position: 0 (1) 31 > 31 Disabled

4.

EFO-NC

0

EFO (emergency fireman operation) position: 0 EFO-P 1 Next commitable landing

5.

EFO-DC

0

EFO with doors c losed: 0 Disabled 1 (1) 255 s DC time

6.

EFO-DO

0

EFO default door: 0 Both doors will open at EFO position 1 Only front door opens 2 Only rear door opens

7.

EFO-OP

0

EFO override option: 0 No override possible 1 XEFO input overrides EFO after arrival at return landing 2 After EFS no EFO is permitted if EFO or AEFO are still active 3 Functions 1 + 2 together

8.

EFONDG

0

Enable nudging speed for EFO 0 Door closes with full speed 1 Door closes with nudging speed

9.

EFO-REV

0

 Al lo wed Rever sal Devices duri ng EFO 0 all devices disabled 1 only SGS/DOS allowed 2 DOB and SGS/DOS allowed

sin ce

OTIS

FIELD COMPONENT MANUAL

Part:

4 - AA3

No.:

GAA26800BA VIIIa

Vintage: 01 / 1

Central & East Europe Area

Software Data

Page:

21 / 21

TCB

Date:

4-Jul-2000

FOD BERLIN

List of Installation Parameters

8 – EMERGENCY No.

Symbol

Default

Purpos e and Range

10.

EFO-MP

0

EFO mode priority 1 ISC has priority 2 ATT has priority 4 EHS has priority note: if more than one of the above options should be available then you must add the appropriate numbers (e.g. to select 1+4 you must program 5)

11.

EFO-MP-T

0

EFO mode priority time 0 (1) 60 s max duration before EFO is started

12.

EFO-SD

0

EFO signal devices 0 no buzzer operation 1 constantly on 2 always flickering 3 constantly without EPO, flickering with EPO

13.

 ASL-P

255

 ASL (alternate s ervic e landi ng) posi ti on: 0 (1) 31 > 31 Disabled

14.

EFS-TYP

0

Type of EFS (Emergency Fireman Servic e) (if EFK (ASL) connected): 0 EFO 1 EFS 1 (Aut.) 2 EFS 2 (Man.) 3 ANSI (USA) 4 British Standard 5 Swiss Standard 6 Australia 7 New Zealand 8 EFS 2 (Man. with ESK) 9 New Zealand with DCB 10 GENERIC

15.

EFS-DO

0

EFS default door: 0 Both doors will open position 1 Only front door opens 2 Only rear door opens

16.

EFSINI

0

EFS init iation 1 2 4 8 16

of Phase II automatically when ISS operated when ESK operated when CFS operated when 1EFS operated

note: if more than one of the above options should be available then you must add the appropriate numbers (e.g. to select 1+4 you must program 5) note: only applicable if EFS-TYP=10

sin ce

OTIS

FIELD COMPONENT MANUAL

Part:

4 - AA3

No.:

GAA26800BA VIIIa

Vintage: 01 / 1

Central & East Europe Area

FOD BERLIN

Software Data

Page:

22 / 22

TCB

Date:

4-Jul-2000

List of Installation Parameters

8 – EMERGENCY No.

Symbol

Default

Purpos e and Range

17.

EFSCLD

0

EFS close door type 1 car button (constant pressure) 2 door close button (constant pressure) 4 up/down start buttons 8 CS start button 16 ANSI style ISC 32 car call demand (momentary pressure) note: if more than one of the above options should be available then you must add the appropriate numbers (e.g. to select 1+4 you must program 5) note: only applicable if EFS-TYP=10

18.

EFSOPD

0

EFS open door type 1 always automatically 2 when DOB constantly pressed 4 only on 1st arrival 8 Door Hold Function if door not fully opened or closed (I/Os DDM, RDDM) note: if more than one of the above options should be available then you must add the appropriate numbers (e.g. to select 2+4 you must program 6) note: valid values are 1, 2, 4 and 6 note: only applicable if EFS-TYP=10

19.

EFS-EX

0

EFS exit t ype 0 only if at EFO landing 1 if not moving and door is open 2 at any landing when door is closed note: only applicable if EFS-TYP=10

20.

EFS-RT

0

EFS return t ime (duration for which EFK must be low to force car back to EFO landing if EFK is switched on again while in EFS): 0-39 Function disabled 40-255 Time (in 100 ms units) EFK must be low

21.

EFS-RC

0

EFS recall type 1 EFK off timeout 2 EFK off, moving 4 EFK off, not moving 8 EFK off, not moving, door closed 16 EFK off, not moving, door opened 32 EFS1 off note: if more than one of the above options should be available then you must add the appropriate numbers (e.g. to select 1+4 you must program 5) note: only applicable if EFS-TYP=10

sin ce

OTIS

FIELD COMPONENT MANUAL

Part:

4 - AA3

No.:

GAA26800BA VIIIa

Vintage: 01 / 1

Central & East Europe Area

FOD BERLIN

Software Data

Page:

23 / 23

TCB

Date:

4-Jul-2000

List of Installation Parameters

8 – EMERGENCY No.

Symbol

Default

Purpos e and Range

22.

EF-I-LT

0

EFO/EFS input latchi ng 1 EFO input is latched 2 AEFO input is latched 4 EFK input is latched 8 ASL input is latched note: if more than one of the above options should be available then you must add the appropriate numbers (e.g. to select 1+4 you must program 5) note: only applicable if EFS-TYP=10

23.

EN-BAK

0

Enable E2P-backup of EFO/EFS: 0 Disable backup 1 Enable backup

24.

HDWPOS

0

Hardware pos ition reference: 0 Disabled 1 One contact per floor 2 Binary coded contacts 3 Signal at every odd floor

25.

EPO-P

255

EPO (emergency power operation) Position: 0 (1) 31 EPO A/C (position) EPO E (hydro: bottom) = 32 EPO B/D (next floor) EPO F (hydro: next floor down) >32 Disabled

26.

EPO-DC

0

EPO with doors c losed: 0 Disabled 1 (1) 255 s

27.

EPO-DO

0

EPO default door: 0 Both doors will open at EPO position 1 Only front door opens 2 Only rear door opens

28.

EPO-PR

0

EPO prio rity if EFO/EFS: 0 No priority for EPO 1 EPO has priority

29.

EQO

0

Earthquake Operation Version: 0 California 1 New Zealand

30.

EPS-TYP

0

Express Priority Service: xx0 automatic ISC xx1 return to normal xx2 automatic CHCS x0x immediate return x1x stop at next commitable landing x2x serve car calls en route 1xx with Tale Tell Lights (EHS-2)

31.

EHS-T

0

EHS time-out: 0 Disabled 1 (1) 255 s

sin ce

OTIS

FIELD COMPONENT MANUAL

Part:

4 - AA3

No.:

GAA26800BA VIIIa

Vintage: 01 / 1

Central & East Europe Area

FOD BERLIN

Software Data

Page:

24 / 24

TCB

Date:

4-Jul-2000

List of Installation Parameters

9 - SECURITY No.

Symbol

Default

Purpos e and Range

0.

EN-FPD

0

Enable FPD (fireproof doors): 0 Disabled 1 Enabled

1.

EN-IST

0

Enable IST (intermittent stop): 0 Disabled 1 In up direction only 2 In down direction only 3 In both directions 5 In up direction only, if ISTS active 6 In down direction only, if ISTS active 7 In both directions, if ISTS active

2.

IST-P

255

Intermittent Stop Position: 0 (1) 31 >31 Disabled

3.

EN-CRO

0

Enable CRO (card reader operation ): 0 Disabled 1 Single contact reader uses CRO-Mask and IO639 (CRC) 2 Australian Card Key sec type 2 uses IOs 480... (CRS0...) and IO665 (BOS) signals are low active 3 Australian Card Key sec type 1 uses IOs 480... (CRS0...) signals are low active 4 Multi contact reader uses IOs 480... (CRS0...) signals are high active CRC is override signal note: CRO-Mask: 0: car call only when CRC active 1: car call allowed any time

4.

GCBTYP

0

General Control of But tons t ype: 0 disabled 1 GCB-1 (car calls disabled; park run allowed) 2 GCB-2 (all calls disabled)

5.

RIOT-P

255

RIOT Operation Position: 0 (1) 31 >31 Disabled

6.

SACTYP

0

Secure Access Type: 0 SAC disabled 1 SAC enabled, without ISC override 3 SAC enabled, with ISC override 5 SAC enabled, without ISC override, clear only possible if security enabled 7 SAC enabled, with ISC override, clear only possible if security enabled else SAC disabled

sin ce

OTIS

FIELD COMPONENT MANUAL

Part:

4 - AA3

No.:

GAA26800BA VIIIa

Vintage: 01 / 1

Central & East Europe Area

FOD BERLIN

Software Data

Page:

25 / 25

TCB

Date:

4-Jul-2000

List of Installation Parameters

9 - SECURITY No.

Symbol

Default

Purpos e and Range

7.

SAC-D1

0

Secure Access di git 1: 0 disabled 1 (1) 6 use CSA1 - CSA6 as code input >6 disabled

8.

SAC-D2

0

Secure Access di git 2: 0 disabled 1 (1) 6 use CSA1 - CSA6 as code input >6 disabled

9.

SAC-D3

0

Secure Access di git 3: 0 disabled 1 (1) 6 use CSA1 - CSA6 as code input >6 disabled

sin ce

OTIS

FIELD COMPONENT MANUAL

Part:

4 - AA3

No.:

GAA26800BA VIIIa

Vintage: 01 / 1

Central & East Europe Area

FOD BERLIN

Software Data

Page:

26 / 26

TCB

Date:

4-Jul-2000

List of Installation Parameters

10 - TEST No.

Symbol

Default

Purpos e and Range

0.

TPOS 1

255

Test pos ition 1(automatic test run): 0 (1) 31 > 31 Disabled

1.

TPOS 2

255

Test pos ition 2(automatic test run): 0 (1) 31 > 31 Disabled

2.

TDELAY

255

Test Delay for automatic test run : 0 (1) 255 s

3.

DEBUG

0

Debug parameter: 0 (1) 255

4.

DEBUG1

0

Debug parameter1: 0 (1) 255

5.

EN-1CL

0

Enable Init_1CL: default position (Mot_VLV): 0 Disabled 1 Enabled

6.

EN-EVT

0

Enable Storage of 10 events into E2PROM: 0 Disabled 1 Enabled

7.

EN-CRT

0

Enable contract handling: operate up to 32 openings 0 Disabled 1 Enabled

8.

DISP-ALL

0

display of inputs in M-1-1-2 (System-Status-Inputs) 0 only those inputs are displayed which are used by the specific configuration 1 all inputs are displayed, even if not available for the specific configuration

sin ce

OTIS Central & East Europe Area

FOD BERLIN

FIELD COMPONENT MANUAL

Part:

4 - AA3

No.:

GAA26800BA VIIIa

Vintage: 01 / 1 Software Data

Page:

27 / 27

TCB

Date:

4-Jul-2000

List of Installation Parameters

Index 1AT ........................................... 10 1LS-D........................................ 18 2AT ........................................... 10 2LS-D........................................ 18 3P ............................................. 10  ACD/UXT .................................. 11  ANS............................................. 6  ARBL -PRK ................................. 5  ARBL -T....................................... 5  ARD-P......................................... 5  ARD-T ......................................... 5  ASL-P ....................................... 21  ATT ............................................. 6 BOTTOM .................................... 2 BRE-Hold ................................. 19 BRE-Tout ................................. 19 CA-MOD ................................... 17 CFT-NT ..................................... 16 CFT-P ......................................... 2 CM-D......................................... 14 CM-PROT ................................. 14 CMR-ES .................................... 15 CM-TYP .................................... 14 CNL............................................. 8 CPC-TYP .................................... 4 CPMT-D ...................................... 6 CPR-T ......................................... 5 CR-DIR ....................................... 4 CR-DO ........................................ 4 CTL/PKS..................................... 5 CTL-DO ...................................... 5 CTL-P ......................................... 5 DAR-T ....................................... 16 DCMT-A ...................................... 6 DCP-T ......................................... 5 DDP .......................................... 10 DEBUG ..................................... 26 DEBUG1 ................................... 26 DFCR-DEL .................................. 4 DHB-T ....................................... 16 DHB-TYP .................................... 7 DISP-ALL .................................. 26 DO-BEL .................................... 15 DOC ............................................ 6 DO-D......................................... 14 DOMT-O ..................................... 6 DOOR ....................................... 12 DOR-T....................................... 16 DRV-TYPE ................................ 10 DS-CCB ...................................... 6 DS-DOB ...................................... 6 DTC-T ....................................... 16 DTO-T ....................................... 16 DUPK-G ...................................... 8 DUPK-P ...................................... 8 DW-DLY.................................... 15 DXT-T ....................................... 16 DZ-DLY ..................................... 17

DZ-TYP......................................17 EF-I-LT ......................................23 EFO-DC .....................................20 EFO-DO.....................................20 EFO-MP.....................................21 EFO-MP-T .................................21 EFO-NC .....................................20 EFONDG ...................................20 EFO-OP .....................................20 EFO-P........................................20 EFO-SD .....................................21 EFSCLD ....................................22 EFS-DO .....................................21 EFS-EX......................................22 EFSINI.......................................21 EFSOPD ....................................22 EFS-RC .....................................22 EFS-RT......................................22 EFS-TY......................................21 EHS-T........................................23 ELD-DOOR .................................3 ELD-fCLG ...................................2 ELD-fOPG...................................2 ELD-LNG.....................................3 ELD-MSG ....................................3 ELD-rCLG ...................................3 ELD-rOPG...................................3 ELD-Sym1...................................3 EN-1CL ......................................26 EN-ADM ....................................12 EN-ADO.....................................10 EN-BAK .....................................23 EN-BSM ......................................2 EN-CK .......................................15 Encoder ....................................19 EN-CRO ....................................24 EN-CRT .....................................26 EN-DDO ....................................12 EN-EVT .....................................26 EN-FPD .....................................24 EN-GSS .......................................9 EN-HLC .......................................3 EN-IST.......................................24 EN-MPD ....................................10 EN-NDG ....................................15 EN-OTS .....................................11 EN-PLS .....................................11 EN-PMO ....................................15 EN-RB .........................................7 EN-RLV .....................................18 EN-RR .........................................4 EN-SFR .......................................3 EN-SHB .......................................5 EN-UCB .......................................8 EN-ZBS .......................................8 EPO-DC.....................................23 EPO-DO ....................................23 EPO-P .......................................23

EPO-PR .................................... 23 EPS-TYP................................... 23 EQO .......................................... 23 ERO-TYP .................................... 4 ES-LRCU .................................. 20 ES-SLOW ................................. 20 ES-TYP ..................................... 20 F:DC-TYP ................................. 13 F:DOL-D ................................... 13 F:DO-TYP ................................. 12 F:EN-ACG................................. 13 F:EN-DCL ................................. 13 GCBTYP ................................... 24 GROUP .......................................8 GRP-NO......................................8 HDL-TY .......................................3 HDWPOS .................................. 23 HL-SET .......................................4 HY-TYP..................................... 10 IPD-D ........................................ 18 IPU-D ........................................ 17 ISC ..............................................6 ISC-T...........................................6 ISPS-TY ......................................6 IST-P......................................... 24 LDR........................................... 15 LOBBY........................................2 LOB-NT..................................... 16 L-PARK.......................................8 LR-MODE ................................... 3 LR-T............................................3 L-T ............................................ 10 LV-D-D ...................................... 17 LV-MOD .................................... 17 LV-U-D ...................................... 17 MAX-C ...................................... 16 MAX-H ...................................... 16 MG-DEL ......................................9 MIN-C........................................ 16 MIN-H........................................ 16 MIT-DOOR.................................. 8 MIT-NLB ..................................... 8 MIT-ST ........................................8 MIT-T ..........................................8 MIT-VD........................................8 MOT-T.........................................8 MPD-T....................................... 10 N+2 WIRE ................................... 4 NDG-T....................................... 15 OPERAT ..................................... 2 PARK-1.......................................7 PARK-2.......................................7 PARK-3.......................................7 PARK-4.......................................7 PARK-5.......................................7 PARK-6.......................................7 PARK-7.......................................7 PARK-8.......................................7

OTIS Central & East Europe Area

FOD BERLIN

FIELD COMPONENT MANUAL

Part:

4 - AA3

No.:

GAA26800BA VIIIa

Vintage: 01 / 1 Software Data

Page:

28 / 28

TCB

Date:

4-Jul-2000

List of Installation Parameters PI ............................................... 2 PI-OPT ........................................ 2 PKS -TY...................................... 5 PKS-DO ...................................... 5 PKS-P ......................................... 5 PKS-T ......................................... 5 P-OFF-D ................................... 11 P-ON-D ..................................... 11 PRKDST ..................................... 9 R:DC-TYP ................................. 13 R:DOL-D................................... 14 R:DO-TYP................................. 13 R:EN-ACG ................................ 13 R:EN-DCL ................................. 13 RDOR-T .................................... 16 REAR ........................................ 12 REM-TYP.................................... 4 RIOT-P...................................... 24

RL-CNT .....................................18 RL-D-D ......................................18 RL-DIS.......................................18 RL-U-D ......................................18 RL-UIS.......................................18 RLV-TY......................................18 SAC-D1 .....................................25 SAC-D2 .....................................25 SAC-D3 .....................................25 SACTYP ....................................24 SDI-Dir ......................................19 SEL-CMR ..................................15 SEL-COMP..................................8 SHO-LT .....................................16 SHO-T .......................................16 SPB-Brk ....................................19 SPB-Buz ...................................19 SPB-Con ...................................19

SPB-NT..................................... 16 SPB-Temp ................................ 19 SPEECH ..................................... 6 SPEED...................................... 10 Spe-Rng ................................... 19 T-BASE..................................... 17 TCI-TYP .................................... 15 TDELAY.................................... 26 TFS-P..........................................8 TOP.............................................2 TPOS 1 ..................................... 26 TPOS 2 ..................................... 26 TRO-TYP .................................. 15 UX-D ......................................... 10 UXT-D ....................................... 10 WCO-T...................................... 16