INTRODUCTION PROCESS DESCRIPTION BATTERY LIMIT CONDITIONS KEY FEATURES OF MAIN EQUIPMENT OPERATING VARIABLE AND PROCESS CONTROL SAFETY INTERLOCKS AND ALARMS ANALYTICAL CONTROL PRECOMMISSIONING PROCEDURE COMMISSIONING PROCEDURE SHUT DOWN PROCEDURE TROUBLE SHOOTING MAINTENANCE DO’S AND DON’TS SAFETY EMERGENCY SHUT DOWN PROCEDURE UTILITY CONSUMPTION ANNEXURES
5 6 7 8 9 10 11 12 13 14 15 16 17
Prepared By:
3 5 8 9 14 16 18 19 40 43 45 48 50 51 54 58 59
SIC
Version No.
00
Doc. No.
EOL/SRU/SWS/RD/001
Reviewed By:
AM
Revision
02
Doc. type
Operating Manual
Approved By
HOD
05.06.11
Page no.
Page 2 of 73
Date
Essar Refinery Integrated Management System
1. INTRODUCTION 1.1 OBJECTIVE The Sour Water Stripping Unit (5100) processes sour water generated in the following units: Crude Distillation Unit (1000) Vacuum Distillation Unit (1100) Amine Regeneration Unit (1200) Saturated Gas Separation Unit (1300) Visbreaker Unit (2000) Naphtha Hydrotreater Unit (3000) Unsaturated Gas Separation Unit (3500) Diesel Hydrodesulphurization Unit (4000) Sulphur Recovery Unit (5000) The Hydrogen Sulphide (H2S) and Ammonia (NH3) present in the sour water are stripped off and are routed to the Sulphur Recovery Unit (5000). The stripped water is partially routed to the Crude desalters of the Crude Distillation Unit (1000). The remaining stripped water is sent to the Waste Water Treatment Plant (8400).
1.2 SECTIONS OF SWS The SWS unit consists of three sections. They are as follows: The degassing section. Sour water stripping section. Low pressure condensate collection section.
1.3 FEED SPECIFICATION The design of the unit is based on the refinery crude mix of 70% Arabian Light and 30% Arabian Heavy. The Unit receives sour water feed from the above said units. The unit is designed to process 185030 kg/hr of sour water. The feed quantity comes to 169467 kg/hr of sour water if the deferred units are not considered. The feed quantity from the individual units and their constituents are listed below.
1.4 PRODUCT SPECIFICATION The stripped water produced in the unit is required to meet the following specifications: H2S: maximum 10 ppm wt. NH3: maximum 100 ppm wt.
1.5 TURNDOWN AND OVERDESIGN REQUIREMENTS The unit is capable of operating at 50% of its hydraulic design capacity. It is also capable of operating at 110% of its hydraulic design capacity. The overdesign on the stripper including the overhead system is based on 10% overdesign on the reboiler duty.
Prepared By:
SIC
Version No.
00
Doc. No.
EOL/SRU/SWS/RD/001
Reviewed By:
AM
Revision
02
Doc. type
Operating Manual
Approved By
HOD
05.06.11
Page no.
Page 4 of 73
Date
Essar Refinery Integrated Management System
2. PROCESS DESCRIPTION The SWS unit consists of three sections. They are as follows: The degassing section. Sour water stripping section. Low pressure condensate collection section.
2.1 DEGASSING SECTION The sour water from CDU/VDU/SGU/VBU/NHT and UGS are collected in the Sour water buffer vessel (75V-001) located in the Visbreaker Unit (VBU). From there it is routed to the Sour water collecting vessel (51V-201) at a pressure of 4 kg/cm2g and temperature of 40°C. The sour water line from DHDS joins the sour water line from VBU to 51V-201. The sour water flashes from 4 kg/cm2g to 0.2 kg/cm2g on entering the collecting vessel as a result of which, the lighter hydrocarbons present in the sour water get separated and are routed to the H 2S flare header. The pressure in this vessel is floating on the flare pressure. Fuel gas is used for blanketing purpose. Liquid hydrocarbons present in the sour water are skimmed off and are pumped by the Slop oil Pump (51P-201) to the Wet slop tank in PIT.
2.2 SOUR WATER STRIPPING SECTION The sour water feed pumps (51P-202A/S) pump the sour water from the collecting vessel (51V-201) to the sour water stripper column (51C-201). The sour water is preheated from 40°C to 68-70°C against the stripped water from the column bottom in the feed/bottom exchanger (51E-201). The sour water stripper column contains 28 trays. Except tray no.6 (which is a chimney tray) all the trays are valve trays. The sour water stripper consists of a washing section (trays 1to 6) and a stripping section (trays 7 to 28). The sour water flow controller to the column is cascaded with the level controller on 51V-201. The sour water enters the stripper column on the 7 th tray. Two vertical thermosyphon type reboilers (51E-202A/B) are provided for heating the column bottom liquid. The stripped water enters the bottom of the reboilers on the tube side and the vapours generated leave the reboiler at the top. Low pressure Steam (LP steam) is used as the heating medium. The flow of LP steam to the reboilers is controlled by a flow controller which is cascaded with the sour water feed controller. The LP steam flow is controlled on ratio with the feed flow. The condensate generated in the reboilers is separated by traps whose downstream is connected to the LP condensate knock out vessel (51V-301).
Prepared By:
SIC
Version No.
00
Doc. No.
EOL/SRU/SWS/RD/001
Reviewed By:
AM
Revision
02
Doc. type
Operating Manual
Approved By
HOD
05.06.11
Page no.
Page 5 of 73
Date
Essar Refinery Integrated Management System
A part of the liquid collected in tray no.6 (chimney tray) is pumped by the circulating reflux water pumps (51P-204A/S) to circulating water air coolers (51EA202A/B), where it is cooled from 98°C to 65°C before entering in the top of the column to wash the overhead gas. The temperature of the overhead gas is controlled by changing the angle of the Fin fan blades (pitch control). The flow of reflux water is controlled by a flow controller. There is a provision for routing the stripped water from the stripped water cooler (51E-203) downstream to the chimney tray. The stripped water from the column bottom, at a temperature of 118°C, is pumped by the stripped water bottom pumps (51P-203A/S) to the feed/bottom exchanger (51E-201) and then to the stripped water air coolers (51EA-201A/B/C/D). The stripped water is cooled to a temperature of around 65°C at the outlet of the air coolers. It is then cooled to 40°C at the outlet of the stripped water trim cooler (51E203). Sea cooling water is used as the cooling medium in 51E-203. The stripped water is then routed partially to the Desalters of the Crude Distillation Unit (CDU). The rest of the stripped water is routed to the Waste Water Treatment Plant (8400) for further treatment. The bottom level controller of 51C-201 controls the stripped water flow to WWTP. A start-up/recycle line is provided for routing the stripped water from the outlet of 51E-203 to 51V-201. This line is used during internal circulation of the plant during start-up/shutdown and also during low throughput of SWS. The stripper top pressure is maintained at 0.9 kg/cm 2g by a pressure controller which is cascaded with the SWS acid gas flow controllers located in the two trains of the Sulphur Recovery Unit (SRU). There is a second pressure controller which vents the overhead gas to the H2S flare in case of a high pressure build-up due to SWS acid gas cut-off in SRU. The stripper overhead line to SRU is steam jacketed in order to avoid plugging due to ammonium salts deposition. In case of a pressure build-up which could not be controlled by the flare pressure controller, two PSVs (51PSV-019A/S) are provided with a set point of 3.5 kg/cm 2g to protect the column.
2.3 LOW PRESSURE CONDENSATE COLLECTION SECTION The Low pressure condensate from the SWS reboilers (51E-202A/B) is routed to the LP condensate flash vessel (51V-301). The vessel also receives low pressure condensate from the ARU reboilers (12E-202A/B/C/D) via the condensate collection vessel (12V-203). It also receives condensate from the LP condensate flash drum (50V-009). The LP condensate produced in DHDS is also routed to this vessel. The vessel is provided with condensate overhead condensers (51EA-301A/B). The
Prepared By:
SIC
Version No.
00
Doc. No.
EOL/SRU/SWS/RD/001
Reviewed By:
AM
Revision
02
Doc. type
Operating Manual
Approved By
HOD
05.06.11
Page no.
Page 6 of 73
Date
Essar Refinery Integrated Management System
condensate from 51V-301 is pumped with condensate pumps (51P-301A/S) to the Refinery LP condensate system on level control.
Prepared By:
SIC
Version No.
00
Doc. No.
EOL/SRU/SWS/RD/001
Reviewed By:
AM
Revision
02
Doc. type
Operating Manual
Approved By
HOD
05.06.11
Page no.
Page 7 of 73
Date
Essar Refinery Integrated Management System
3. BATTERY LIMIT CONDITIONS S.NO.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
TEMPERATURE (°C) DESIGN OPERATING
SERVICE
Sour Water Acid gas to SRU Stripped water to CDU Stripped water to WWTP Fuel Gas Low Pressure Steam Demineralized Water Sea Cooling Water Supply Sea Cooling Water Return Sweet Cooling Water Supply Sweet Cooling water Return Service Water Instrument Air Plant Air Nitrogen