Step by Step Dus Integration

February 9, 2017 | Author: Rashad Ahmad | Category: N/A
Share Embed Donate


Short Description

hi...

Description

STEP BY STEP DUS INTEGRATION 1- Connect DUS Splitter to LMT port in the DUS 2- Connect a serial to USB cable from Port LMT A at the splitter to client usb port. 3- Open a hyper terminal (Eg: TerraTerm) 4-Put the DUS in backup mode: $ reload -OSE Delta PowerPC/BL410393 Welcome to OSE Shell ose5.5. Start of @(#)CXC1731599 R2A13 2012-02-17 09:46:41 GMT $ Plug-in Unit Product Name: DUS4101 Plug-in Unit Product No: KDU137624/1 Plug-in Unit Product rev: R3C Plug-in Unit Product Date: 20120903 Plug-in Unit Product Serial: C826325559 Ethernet MAC_address 0: 0x9055AE526F8D RAM size: 2048 Mbytes Stop due to remain in basic/backup set 5-Format both drive D and C2 $ formathd /d All data on volume will be destroyed. Continue? y/n (n):y Formatting Hard Disk... $ $ reload -OSE Delta PowerPC/BL410393 Welcome to OSE Shell ose5.5. Start of @(#)CXC1731599 R2A13 2012-02-17 09:46:41 GMT $ Plug-in Unit Product Name: DUS4101 Plug-in Unit Product No: KDU137624/1

Plug-in Unit Product rev: R3C Plug-in Unit Product Date: 20120903 Plug-in Unit Product Serial: C826325559 Ethernet MAC_address 0: 0x9055AE526F8D RAM size: 2048 Mbytes Stop due to remain in basic/backup set $ formathd /c2 All data on volume will be destroyed. Continue? y/n (n):y Formatting Hard Disk... $ $ reload -OSE Delta PowerPC/BL410393 Welcome to OSE Shell ose5.5. Start of @(#)CXC1731599 R2A13 2012-02-17 09:46:41 GMT $ Plug-in Unit Product Name: DUS4101 Plug-in Unit Product No: KDU137624/1 Plug-in Unit Product rev: R3C Plug-in Unit Product Date: 20120903 Plug-in Unit Product Serial: C826325559 Ethernet MAC_address 0: 0x9055AE526F8D RAM size: 2048 Mbytes Stop due to remain in basic/backup set 6- Set IP $ ifconfig le0 169.254.1.10 netmask 255.255.0.0 $ ifconfig le0: inet 169.254.1.10 netmask 255.255.0.0 broadcast 169.254.255.255 $ ----------------------------------------------------------------------------------------------------------Connect Ethernet cable to Port LMT B at the splitter to Ethernet Port at client Turn of anti-virus/Symantec Change laptop IP to the following:

7- FTP Basic Package Connect to DUS using FTP and transfer directory /c2 and /d of the basic package CXP9021502%16_R21CK to directory /c2 and /d of the DUS. Do ensure your transfer mode set to Binary

8- Activate Basic Package $ reload OSE Delta PowerPC/BL410393 Welcome to OSE Shell ose5.5. Start of @(#)CXC1731599 R2A13 2012-02-17 09:46:41 GMT $ Plug-in Unit Product Name: DUS4101 Plug-in Unit Product No: KDU137624/1 Plug-in Unit Product rev: R3C Plug-in Unit Product Date: 20120903 Plug-in Unit Product Serial: C826325559 Ethernet MAC_address 0: 0x9055AE526F8D RAM size: 2048 Mbytes BoardMgr: Starting Configuration Version: basic_cv CM State: Fallback (own)

Copying new boot image to flash.. Image copied suÿ OSE Delta PowerPC/BL410512 username: Start of @(#)CXC1731602 R79X10 2012-06-18 07:54:20 GMT Plug-in Unit Product Name: DUS4101 Plug-in Unit Product No: KDU137624/1 Plug-in Unit Product rev: R3C Plug-in Unit Product Date: 20120903 Plug-in Unit Product Serial: C826325559 Ethernet MAC_address 0: 0x9055AE526F8D RAM size: 2048 Mbytes BoardMgr: Starting Configuration Version: basic_cv CM State: NormalActive (own), Undefined (peer), peer supa=0xffffffff Component rtrdb (V08.05.0000 (PATCH-A)/OSE-powerpc EMBEDDED) Copyright (C) 1994-2012 by Enea Software AB Constructing Database rtrdb RTRDB: Default persistence is transient Loading '/gzip//d/configuration/cv/basic_cv/db.dat' Ready All programs loaded and started All configured PIUs started on node Login Server Ready --------------activate basic package done. Reconnect to DUS using hyperterminal-----username: rbs password: Welcome to OSE Shell ose5.5. $ $ $ cv ls Please wait for list.... Name: basic_cv Date: Sat Aug 25 22:29:19 2012 Id: no value (cv product id) Type: other Package upgrade: CXP102051/16_R21CK Operator: no value (operators name) Comment: no value (operators comments) Status: ok

Number of CVs = 1 (Max 50) $ $ vols volume total used free frw device unit / 0K 0K 100% 0K 100% FR/null 0K 0K 100% 0K 100% FRW /gzip 1K 1K 100% 0K 0% -RW none /mole 1K 1K 100% 0K 0% -RW none /erpdout 1K 1K 100% 0K 0% -RW none /ffs 1K 1K 100% 0K 0% -RW none /rmd 1014K 22K 2% 992K 98% FRW ram_disk 0 /h 1014K 14K 1% 1000K 99% FRW ram_disk 1 /d 976M 123M 13% 852M 87% FRW usbdd 0 /zip 1K 1K 100% 0K 0% -RW none /c 5859M 257M 4% 5602M 96% FRW usbdd 0 /j 5859M 257M 4% 5602M 96% FRW /c 0 $ 9- Upgrade Package Ftp L12B ICP4 CXP102051%16_R25AK Upgrade package folder to directory /c/tmp in DUS

10- Once upgrade package transferred, connect to hyperterminal and reload $ reload OSE Delta PowerPC/BL410512 username: Start of @(#)CXC1731602 R79X10 2012-06-18 07:54:20 GMT

Plug-in Unit Product Name: DUS4101 Plug-in Unit Product No: KDU137624/1 Plug-in Unit Product rev: R3C Plug-in Unit Product Date: 20120903 Plug-in Unit Product Serial: C826325559 Ethernet MAC_address 0: 0x9055AE526F8D RAM size: 2048 Mbytes BoardMgr: Starting Configuration Version: basic_cv CM State: NormalActive (own), Undefined (peer), peer supa=0xffffffff All programs loaded and started Component rtrdb (V08.05.0000 (PATCH-A)/OSE-powerpc EMBEDDED) Copyright (C) 1994-2012 by Enea Software AB Constructing Database rtrdb RTRDB: Default persistence is transient Loading '/gzip//d/configuration/cv/basic_cv/db.dat' Ready All configured PIUs started on node Login Server Ready

11- Connect to EM with 169.254.1.10 IP Go to Upgrade and Backup Go to UP tab

Click on Create UP button and fill up the following and click create package button.

Next, click on Install Package button when it became visible.

Click on Full Install

Click on Upgrade Node, and select Hard Upgrade

Click on Confirm Upgrade and Select Make upgrade permanent – Yes.

Upgrade Node complete.

Create CV

Set autoConfigurationAllowed to TRUE

Upgrade SW done.