ANNEXURE-1 INPUTS REQUIRED OF CONGO CROSS SUBSTATION S.No.
Activity
Inputs Required
Responsibility (K & A)
Substations wise Inputs Required : 1
a) Congo Cross 11KV Switchgear
1) Incomer from Kingtom -1 details : a)
Cable details
Number of runs
1
Number of core
3
Area of conductor
3 x 185 mm2
Type of conductor
AL
Length of cable
2862 m
Type of Insulation
PILC
Type of Shield Type of Sheath Armour & Jacket Impedance ( Zero, Positive & Negative – R Parameter ) Impedance ( Zero, Positive & Negative – X Parameter ) Impedance ( Zero, Positive & Negative – L Parameter ) Impedance ( Zero, Positive & Negative – Z Parameter ) Impedance ( Zero, Positive & Negative – C Parameter ) b)
Protection Relay details
Type
MCGG
Model Number Type of Curve
MCGG52H1CD0753D STANDARD INVERSE
Relay Setting values of existing system
420 A 400 A
c)
Maximum Load Demand
d)
Power Factor
e)
X/R ratio.
f)
Circuit Breaker Operation Philosophy
0.8
g) Short Circuit Current (KA)
20kA@3s
2) Outgoing to Murray Town details: STEG(No Breaker) a)
Cable details
Number of runs
1
1
Number of core
3
Area of conductor
185mm2
Type of conductor
copper
Date of Received Inputs
Remarks
Length of cable Type of Insulation
XLPE
Type of Shield Type of Sheath Armour & Jacket Impedance ( Zero, Positive & Negative – R Parameter ) Impedance ( Zero, Positive & Negative – X Parameter ) Impedance ( Zero, Positive & Negative – L Parameter ) Impedance ( Zero, Positive & Negative – Z Parameter ) Impedance ( Zero, Positive & Negative – C Parameter ) b)
Protection Relay details
Type
MCGG MCGG52H1CD0753D
Model Number Type of Curve
STANDARD INVERSE 220 A
Relay Setting values of existing system
400 A
c)
Maximum Load Demand
d)
Power Factor
e)
X/R ratio.
f)
Circuit Breaker Operation Philosophy
0.8
g) Short Circuit Current (KA)
20kA@3s
3) Outgoing to Murray Town details: a)
Cable details
Number of runs
1(ABC)
Number of core
3
Area of conductor
3 x 150 mm2
Type of conductor
Al
Length of cable
250 m
Type of Insulation
XLPE
Type of Shield Type of Sheath Armour & Jacket Impedance ( Zero, Positive & Negative – R Parameter ) Impedance ( Zero, Positive & Negative – X Parameter ) Impedance ( Zero, Positive & Negative – L Parameter ) Impedance ( Zero, Positive & Negative – Z Parameter )
Impedance ( Zero, Positive & Negative – C Parameter ) b)
Protection Relay details
Type
MCGG MCGG52H1CD0753D
Model Number Type of Curve
STANDARD INVERSE 320 A
Relay Setting values of existing system
400 A
c)
Maximum Load Demand
d)
Power Factor
e)
Circuit Breaker Operation Philosophy
0.8
f) Short Circuit Current (KA)
4) Outgoing to Signal Hill HT feeder details: a)
Cable details
Number of runs
1
Number of core
3
Area of conductor
3 x 240 mm2
Type of conductor
COPPER
Length of cable
1100 m
Type of Insulation
PILC
Type of Shield Type of Sheath Armour & Jacket Impedance ( Zero, Positive & Negative – R Parameter ) Impedance ( Zero, Positive & Negative – X Parameter ) Impedance ( Zero, Positive & Negative – L Parameter ) Impedance ( Zero, Positive & Negative – Z Parameter ) Impedance ( Zero, Positive & Negative – C Parameter ) b)
Protection Relay details
Type
MCGG MCGG52H1CD0753D
Model Number Type of Curve
STANDARD INVERSE
Relay Setting values of existing system c)
Maximum Load Demand
d)
Power Factor
e)
Circuit Breaker Operation Philosophy
f) Short Circuit Current (KA)
260 A 400 A 0.8
20kA@3s
5) Bus Coupler details (No Breaker): a)
Cable details
Number of runs Number of core Area of conductor Type of conductor Length of cable Type of Insulation Type of Shield Type of Sheath Armour & Jacket Impedance ( Zero, Positive & Negative – R Parameter ) Impedance ( Zero, Positive & Negative – X Parameter ) Impedance ( Zero, Positive & Negative – L Parameter ) Impedance ( Zero, Positive & Negative – Z Parameter ) Impedance ( Zero, Positive & Negative – C Parameter ) b)
Protection Relay details
Type
MCGG MCGG52H1CD0753D
Model Number Type of Curve
STANDARD INVERSE 260 A
Relay Setting values of existing system c)
Circuit Breaker Operation Philosophy.
d) Short Circuit Current (KA)
6) Outgoing to Wilberforce HT feeder details : a)
Cable details
Number of runs
1
Number of core
3
Area of conductor
185 mm2
Type of conductor
COPPER
Length of cable
2500 m
Type of Insulation
XLPE
Type of Shield Type of Sheath Armour & Jacket Impedance ( Zero, Positive & Negative – R Parameter ) Impedance ( Zero, Positive & Negative – X Parameter ) Impedance ( Zero, Positive & Negative – L Parameter )
150 ACSR
Impedance ( Zero, Positive & Negative – Z Parameter ) Impedance ( Zero, Positive & Negative – C Parameter ) b)
Protection Relay details
Type
MCGG MCGG52H1CD0753D
Model Number Type of Curve
STANDARD INVERSE 520 A
Relay Setting values of existing system c)
Circuit Breaker Operation Philosophy.
d) Short Circuit Current (KA)
20kA@3s
7) Outgoing to Bata Plastic HT feeder details : a)
Cable details
1
Number of runs
3
Number of core Area of conductor
3 x 120 mm2
Type of conductor
COPPER
Length of cable
2500 m
Type of Insulation
XLPE
Type of Shield Type of Sheath Armour & Jacket Impedance ( Zero, Positive & Negative – R Parameter ) Impedance ( Zero, Positive & Negative – X Parameter ) Impedance ( Zero, Positive & Negative – L Parameter ) Impedance ( Zero, Positive & Negative – Z Parameter ) Impedance ( Zero, Positive & Negative – C Parameter ) b)
Protection Relay details
Type Model Number Type of Curve
MCGG MCGG52H1CD0753D STANDARD INVERSE
Relay Setting values of existing system c)
Maximum Load Demand
d)
Power Factor
e)
Circuit Breaker Operation Philosophy.
200 A 200 A 0.8
f) Short Circuit Current (KA)
8) Outgoing to Technical Institute details: (No Breaker & Cable is Faulty) Faulty
a)
Cable details
Number of runs
NO CABLE
Number of core Area of conductor Type of conductor Length of cable Type of Insulation Type of Shield Type of Sheath Armour & Jacket Impedance ( Zero, Positive & Negative – R Parameter ) Impedance ( Zero, Positive & Negative – X Parameter ) Impedance ( Zero, Positive & Negative – L Parameter ) Impedance ( Zero, Positive & Negative – Z Parameter ) Impedance ( Zero, Positive & Negative – C Parameter ) b)
Protection Relay details
Type
MCGG
Model Number Type of Curve
MCGG52H1CD0753D STANDARD INVERSE
Relay Setting values of existing system
260 A
c)
Maximum Load Demand
400 A
d)
Power Factor.
e)
0.8
Circuit Breaker Operation Philosophy.
f) Short Circuit Current (KA)
9) Outgoing to Local Trafo of 1000 KVA details: a)
Cable details
Number of runs Number of core
1 single
Area of conductor
1 x 70 mm2
Type of conductor
COPPER
Length of cable Type of Insulation
8m XLPE
Type of Shield Type of Sheath Armour & Jacket Impedance ( Zero, Positive & Negative – R Parameter ) Impedance ( Zero, Positive & Negative – X Parameter )
Impedance ( Zero, Positive & Negative – L Parameter ) Impedance ( Zero, Positive & Negative – Z Parameter ) Impedance ( Zero, Positive & Negative – C Parameter ) b)
Protection Relay details
Type
MCGG MCGG52H1CD0753D
Model Number
STANDARD INVERSE
Type of Curve
Relay Setting values of existing system
50 A
c)
Maximum Load Demand
50 A
d)
Power Factor.
e)
0.8
Circuit Breaker Operation Philosophy.
f) Short Circuit Current (KA)
10) Incomer from Freetown 161 JICA HT details : a)
Cable details
Number of runs
1
Number of core
3
3 x185mm2
Area of conductor
COPPER
Type of conductor Length of cable
200 m (UG) + 3300m (OHL)
XLPE
Type of Insulation Type of Shield Type of Sheath Armour & Jacket
Impedance ( Zero, Positive & Negative – R Parameter ) Impedance ( Zero, Positive & Negative – X Parameter ) Impedance ( Zero, Positive & Negative – L Parameter ) Impedance ( Zero, Positive & Negative – Z Parameter ) Impedance ( Zero, Positive & Negative – C Parameter ) b)
Protection Relay details
Type
MCGG MCGG52H1CD0753D
Model Number Type of Curve
STANDARD INVERSE
Relay Setting values of existing system c) Circuit Breaker Operation Philosophy. d) Short Circuit Current (KA)