SRAL XD 3.7 Training Manual

May 1, 2017 | Author: Edwin Giraldo | Category: N/A
Share Embed Donate


Short Description

Download SRAL XD 3.7 Training Manual...

Description

s

Training Manual SRAL XD (plug-in IDU) SVR 3.7 Low Capacity Digital Radio - 7...38 GHz Training documentation IMC 0031METD Issue 1, June 2006

Copyright (C) Siemens S.p.A. 2006 V.le Piero e Alberto Pirelli, 10 I-20126 Milano

Issued by Customer Documentation Department S.S. 11 Padana Superiore, km 158 I-20060 Cassina de’ Pecchi MI

DISCLAIMER Siemens may have patents, patent applications, trademarks, copyrights, or other intellectual property rights relevant to the subject matters present in this document. If not explicitly defined by a license agreement written by Siemens, the ownership of this document does not give any use license for the above mentioned patents, trademarks, copyrights, or other intellectual properties. For your convenience, Siemens may make this document available. The entire risk deriving from the use, or the results of the use, of this document are at user’s charge. The information contained in this document is subjected to changes without notice. Technical specifications and features are binding only insofar as they are specifically and expressly agreed previously in a written contract. Siemens gives no assurance relevant to the accuracy of the results or of the output deriving from such information. In case of utilization of the information transferred by means of this document, we advise You to verify if the export licenses, required by the laws, have been granted or if there are not any other impediments arising from the laws in course in Italy, Germany or relevant to the export.

index

SRAL XD (plug-in IDU) SVR 3.7 Low Capacity Digital Radio 7...38 GHz

Safety Rules

1

Glossary

2

SYSTEM DESCRIPTION

3

PHYSICAL INTERFACES

4

CONFIGURATIONS

5

FUNCTIONAL DESCRIPTION

6

PROTECTION SYSTEM ARCHITECTURE

7

SERVICE CHANNELS MANAGEMENT AND PROTECTION

8

EXTERNAL CONNECTIONS

9

Training Manual

IMC 0031METD Issue 1, June 2006

ACTIVATION

10

LOOP BACK

11

MAINTENANCE

12

TECHNICAL CHARACTERISTICS

13 14 15

SRAL XD (plug-in IDU)

Siemens

Status of Manual STATUS OF MANUAL –

Current:



Previous:

Issue 1, June 2006

1 Chp. 1

Safety Rules

Issue 1, June 2006

2 Chp. 2

Glossary

Issue 1, June 2006

3 Chp. 3

SYSTEM DESCRIPTION

Issue 1, June 2006

4 Chp. 4

PHYSICAL INTERFACES

Issue 1, June 2006

5 Chp. 5

CONFIGURATIONS

Issue 1, June 2006

6 Chp. 6

FUNCTIONAL DESCRIPTION

Issue 1, June 2006

7 Chp. 7

PROTECTION SYSTEM ARCHITECTURE

Issue 1, June 2006

8 Chp. 8

SERVICE CHANNELS MANAGEMENT AND PROTECTION

Issue 1, June 2006

9 Chp. 9

EXTERNAL CONNECTIONS

Issue 1, June 2006

10 Chp. 10

ACTIVATION

Issue 1, June 2006

11 Chp. 11

LOOP BACK

Issue 1, June 2006

12 Chp. 12

MAINTENANCE

Issue 1, June 2006

13 Chp. 13

TECHNICAL CHARACTERISTICS

Issue 1, June 2006

IMC 0031METD Issue 1, June 2006 © 2006 Siemens AG

V

Siemens

SRAL XD (plug-in IDU)

Warnhinweise In elektrischen Anlagen stehen zwangsläufig bestimmte Teile der Geräte unter Spannung. Einige Teile können auch eine hohe Betriebstemperatur aufweisen. Eine Nichtbeachtung dieser Situation und der Warnhinweise kann zu Körperverletzung und Sachschäden führen. Deshalb wird vorausgesetzt, dass nur geschultes und qualifiziertes Personal die Anlagen installiert und wartet. Beachten sie bitte die nötigen Sicherheitsanforderungen und leisten Sie durch ein problembewußtes Verhalten Ihren Beitrag zur Verhütung von Unfällen jeder Art. Gefahren für Leib und Leben / Leben und Gesundheit bzw. Verletzungen, die aus sicherheitswidrigem Verhalten resultieren können, sind von einer Haftung durch das Training Institute ausgeschlossen.

Warning High Voltages are present in certain parts of this equipment. Some parts can also have high operating temperatures. Non-observance of these conditions and the safety instructions can result in personal injury or in equipment damage. Therefore only trained and qualified personnel may install and maintain the system. Please ensure the necessary safety requirements are met and, by demonstrating a responsible attitude, play your part in avoiding accidents of any kind. Danger to life and limb, life and well being or injuries that could result from actions adverse to safety are excluded from any liability on the part of the Training Institute.

Atención Algunos elementos de este equipo presentan tensiones altas. Incluso algunos componentes pueden presentar alta temperatura. No observar estas condiciones y las instrucciones de seguridad puede causar daños personales, así como daños al equipo. Por lo tanto el sistema debe ser instalado y mantenido por personal cualificado. Tenga presente los requerimientos de seguridad y contribuya a la prevención de accidentes de toda índole, actuando consciente de los problemas que pudieran surgir. El Training Institute' no se responsabiliza por daños y perjuicios resultantes de actuaciones contrarias a los aspectos de seguridad y que pongan en peligro la salud y la vida de las personas involucradas.

Attention Des tensions élevées sont inévitablement présentes à des points spécifiques de cet équipement électrique. Certains éléments peuvent aussi avoir en service des température élevées. La non-observation de ces conditions et des instructions de sécurité peut engendrer des dégats personnelles ou un endommagement du matériel. Pour ces raisons seulement le personnel formé et qualifié est permis d’installer et de maintenir le système. Veuillez tenir compte des exigences de sécurité nécessaires et contribuer à la prévention des accidents de toutes sortes par un comportement conscient des risques. Le Training Institute décline toute responsabilité pour les dangers menaçant le corps et la vie / la vie et la santé et/ou les blessures pouvant résulter d'actes contraires à la sécurité.

VI

IMC 0031METD Issue 1, June 2006 © 2006 Siemens AG

SRAL XD (plug-in IDU)

Siemens

Attenzione In certe parti dell’apparato sono presenti alte tensioni. In servizio, certi componenti possono raggiungere temperature elevate. La non osservanza di queste condizioni e delle istruzioni di sicurezza può provocare incidenti alle persone o danni all’apparato. Per questo l’installazione e la manutenzione del sistema deve essere affidata solo a personale qualificato e preparato. Assicurarsi che i requisiti di sicurezza siano soddisfatti e contribuire alla prevenzione di incidenti di qualsiasi tipo tenendo sempre in considerazione i rischi presenti. Il “Training Institute” declina ogni responsabilità relativa a danni alla salute e alla vita del personale conseguenza di azioni ed interventi che non rispettano le procedure di sicurezza.

IMC 0031METD Issue 1, June 2006 © 2006 Siemens AG

VII

Siemens

VIII

SRAL XD (plug-in IDU)

IMC 0031METD Issue 1, June 2006 © 2006 Siemens AG

SRAL XD (plug-in IDU)

Siemens

INDEX 1 1.1 1.2

1.3 2 2.1 3 3.1 3.2 3.3 3.4 3.5

3.6

4 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 5 5.1 5.2 5.3 5.4 5.5 5.6 6 6.1

Safety Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1 Safety rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1 1.2.1 Electrical safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.1 1.2.1.1 Warnings for the electrical safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.1 1.2.1.2 Waste equipment management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.1 1.2.2 External operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.3 ESDS Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.4 Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.1 List of abbreviations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1 SYSTEM DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.1 SRAL XD system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1 System building . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1 System configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2 Network Topologies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2 IDU-ODU Interconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2 3.5.1 51.84 Mbit/s or 155.520 Mbit/s signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.3 3.5.2 ODU Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.3 Supporting frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.3 3.6.1 1+0 supporting frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.3 3.6.2 1+1 Supporting frame for frequency diversity . . . . . . . . . . . . . . . . . . . . . . . .3.4 3.6.3 1+1 Supporting frame for Hot stand-by with integrated antenna . . . . . . . . . .3.4 3.6.4 1+1 Supporting frame for Hot stand-by with independent antenna . . . . . . . .3.4 PHYSICAL INTERFACES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.1 Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1 E1 Tributary signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1 Ethernet (10/100 baseT) tributary signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1 E3 tributary signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1 WST signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1 User channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2 Alarm and remote control external lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2 Monitoring of received RF power on the ODU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2 Supervision interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2 CONFIGURATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5.1 16xE1 IDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1 32xE1 IDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1 1xE3 IDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2 ETH IDU ( 4xLAN + 8xE1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2 Licence fee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2 Configuration summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.3 FUNCTIONAL DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6.1 IDU ARCHITECTURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1

IMC 0031METD Issue 1, June 2006 © 2006 Siemens AG

1

Siemens

SRAL XD (plug-in IDU)

6.1.1 IDU (16xE1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1 6.2 2 Mbit/s (16xE1) Tributary Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1 6.3 BB (16xE1) Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.2 6.4 Controller unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.3 6.5 IDU (32xE1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.3 6.5.1 2 Mbit/s (32xE1) Tributary Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.4 6.5.2 BB (32xE1) Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.5 6.5.3 Controller unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.6 6.6 IDU (1xE3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.6 6.6.1 34 Mbit/s (1xE3) Tributary Unit + 2 Mbit/s WST . . . . . . . . . . . . . . . . . . . . . . 6.7 6.6.2 BB (1xE3) Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.7 6.7 Controller unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.8 6.8 IDU (ETH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.8 6.8.1 4xLAN (10/100BaseT) + 8x2 Mbit/s (8xE1) Tributary Unit (DATA INTERFACE UNIT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.9 6.8.1.1 Data interface unit description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.9 6.8.1.2 BB (16xE1) Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.13 6.8.1.3 Controller unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.14 6.9 IDU composition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.14 6.9.1 IDU 16xE1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.14 6.9.2 IDU 1xE3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.16 6.9.3 IDU ETH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.17 6.10 IDU 32xE1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.19 6.11 LED, MONITORING POINTS, CONNECTORS AND SWITCHES . . . . . . . . . . . . . 6.20 6.12 ODU ARCHITECTURE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.22 6.12.1 BB-I (Base-Band and Cable Interface) Section. . . . . . . . . . . . . . . . . . . . . . 6.22 6.12.2 Power Supply Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.22 6.12.3 Modem Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.22 6.12.4 Controller Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.22 6.12.5 IF section. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.23 6.12.6 RF Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.23 6.12.7 ODU identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.23 6.12.8 “Vertical” polarization application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.24 6.12.9 “Horizontal” polarization application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.24 6.12.10 “Rx field measure” connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.24 7 PROTECTION SYSTEM ARCHITECTURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.1 7.1 Tributary Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.1 7.2 Rx tributary Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.2 7.2.1 Tx tributary Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.2 7.2.2 Protection Structures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.3 7.2.3 Hardware protection logic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.4 7.2.4 Hitless protection logic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.6 8 SERVICE CHANNELS MANAGEMENT AND PROTECTION. . . . . . . . . . . . . . . . . . 8.1 8.1 User channel (USR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.2

2

IMC 0031METD Issue 1, June 2006 © 2006 Siemens AG

SRAL XD (plug-in IDU)

9 9.1

9.2

9.3

9.4 10 10.1

10.2

10.3

11 11.1 12 12.1

Siemens

8.1.1 Radio Embedded Communication Channel (R) . . . . . . . . . . . . . . . . . . . . . . .8.2 8.1.2 Tributary Embedded Communication Channel (D) . . . . . . . . . . . . . . . . . . . .8.3 EXTERNAL CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9.1 16xE1 IDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.1 9.1.1 Primary supply voltage connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9.1 9.1.2 Connector functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9.1 1xE3 IDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.1 9.2.1 Primary supply voltage connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9.1 9.2.2 Connector functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9.1 ETH IDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.2 9.3.1 Primary supply voltage connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9.2 9.3.2 Connector functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9.2 32xE1 IDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.2 9.4.1 Primary supply voltage connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9.2 ACTIVATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10.1 PRESETTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.1 10.1.1 Hardware settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10.1 10.1.1.1 System E2PROM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10.1 ACTIVATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.2 10.2.1 Local checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10.2 10.2.2 IDU first installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10.2 10.2.3 Alignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10.3 10.2.4 Local checks on the equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10.3 10.2.4.1 Control of the system configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10.3 10.2.4.2 Configuration of IP address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10.4 10.2.5 Link checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10.4 10.2.5.1 Final checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10.4 10.2.5.2 Switching test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10.4 10.2.5.3 Restore of the operating conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10.4 NORMAL OPERATING CONDITIONS AND ALARMS . . . . . . . . . . . . . . . . . . . . . . 10.5 10.3.1 Normal operating conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10.5 10.3.2 Alarm conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10.5 LOOP BACK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11.1 Loop-backs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.1 11.1.1 Tributary loop-backs (Fig. 11.1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11.1 MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12.1 TROUBLESHOOTING AND RESTORING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.1 12.1.1 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12.1 12.1.2 Unit replacement procedures in 1+0 systems . . . . . . . . . . . . . . . . . . . . . . .12.2 12.1.2.1 ODU replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12.2 12.1.2.2 IDU-ODU cable replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12.2 12.1.2.3 Replacement of the IDU units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12.2 12.1.2.4 ODU replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12.3 12.1.2.5 IDU-ODU cable replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12.4

IMC 0031METD Issue 1, June 2006 © 2006 Siemens AG

3

Siemens

12.2

12.3

13 13.1

13.2 13.3

4

SRAL XD (plug-in IDU)

12.1.2.6 Replacement of the IDU units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.4 12.1.3 Configuration change . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.5 LIST OF SPARE PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.6 12.2.1 IDU spare parts list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.6 12.2.2 ODU spare parts list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.7 PROCEDURE FOR SPARE PARTS USE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.10 12.3.1 Procedure for the IDU unit replacement . . . . . . . . . . . . . . . . . . . . . . . . . . 12.10 12.3.2 Procedure for the ODU replacement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.11 TECHNICAL CHARACTERISTICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.1 General characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.1 13.1.1 ODU ND characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.8 13.1.1.1 Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.8 13.1.1.2 Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.9 13.1.2 ODU HD/HP characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.10 13.1.2.1 Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.10 13.1.2.2 Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.11 13.1.3 ODU HDe characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.13 13.1.3.1 Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.13 13.1.3.2 Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.14 13.1.4 IDU characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.16 13.1.4.1 Protected configuration specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.16 13.1.4.2 Operating mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.16 13.1.4.3 Hardware alarm detection time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.16 13.1.4.4 Operational switching time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.16 13.1.4.5 Characteristics of 2 Mbit/s tributary interface (E1) . . . . . . . . . . . . . . . . . . 13.17 13.1.4.6 Characteristics of 34 Mbit/s tributary Interface (E3) . . . . . . . . . . . . . . . . . 13.17 13.1.4.7 Characteristics of Ethernet ports interface . . . . . . . . . . . . . . . . . . . . . . . . 13.18 13.1.4.8 Characteristics of channel auxiliary interfaces . . . . . . . . . . . . . . . . . . . . . 13.18 13.1.4.9 Power supply characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.20 13.1.5 Guaranteed consumptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.20 13.1.6 Mechanical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.21 13.1.7 Environmental conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.22 13.1.8 EMC/EMI characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.22 13.1.9 Safety characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.23 13.1.10 Antenna P/N . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.23 IDU/ODU CONNECTION WITH BRAIDED COAXIAL CABLE . . . . . . . . . . . . . . . 13.24 13.2.1 Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.24 IDU/ODU CONNECTION WITH 1/4” COAXIAL CABLE. . . . . . . . . . . . . . . . . . . . 13.27 13.3.1 1/4” coaxial cable - Connection on IDU side . . . . . . . . . . . . . . . . . . . . . . . 13.27 13.3.2 Andrew and RFS-Kabelmetal sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.27 13.3.3 Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.28

IMC 0031METD Issue 1, June 2006 © 2006 Siemens AG

SRAL XD (plug-in IDU)

Siemens

LIST OF FIGURES Fig. 3.1 Fig. 3.2 Fig. 3.3 Fig. 3.4 Fig. 3.5 Fig. 3.6 Fig. 3.7 Fig. 3.8 Fig. 3.9 Fig. 3.10 Fig. 3.11 Fig. 3.12 Fig. 3.13 Fig. 3.14 Fig. 3.15 Fig. 3.16 Fig. 3.17 Fig. 3.18 Fig. 4.1 Fig. 4.2 Fig. 4.3 Fig. 4.4 Fig. 4.5 Fig. 5.1 Fig. 5.2 Fig. 5.3 Fig. 5.4 Fig. 5.5 Fig. 5.6 Fig. 5.7 Fig. 5.8 Fig. 5.9 Fig. 5.10 Fig. 5.11 Fig. 5.12 Fig. 5.13 Fig. 5.14

SRAL XD equipment block diagram (with 16xE1 IDU) . . . . . . . . . . . . . . . . . . . . . 3.5 SRAL XD equipment block diagram (with 32xE1 IDU) . . . . . . . . . . . . . . . . . . . . . 3.6 SRAL XD equipment block diagram (with 1xE3 IDU) . . . . . . . . . . . . . . . . . . . . . 3.7 SRAL XD equipment block diagram (with ETH IDU) . . . . . . . . . . . . . . . . . . . . . . 3.8 1+0 system with 1 integrated antenna (Terminal) . . . . . . . . . . . . . . . . . . . . . . . . 3.9 1+0 system with 1 independent antenna (Terminal). . . . . . . . . . . . . . . . . . . . . . 3.10 2x(1+0) dual terminal system, Repeater A/D with 2 integrated antennas . . . . . 3.11 2x(1+0) dual terminal system, Repeater A/D with 2 independent antennas. . . . 3.12 1+1 FD, PD system with 2 integrated antennas (Terminal) . . . . . . . . . . . . . . . . 3.13 1+1 FD, PD system with 2 independent antennas (Terminal) . . . . . . . . . . . . . . 3.14 1+1 PD system with 1 independent antenna (Terminal). . . . . . . . . . . . . . . . . . . 3.15 SRAL XD - 7/8 GHz: 1+1 H/S, FD system with 1 independent antenna (Terminal) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.16 SRAL XD - 13-38 GHz: 1+1 H/S system with 1 integrated antenna (Terminal) . 3.17 SRAL XD - 13-38 GHz: 1+1 H/S system with 1 independent antenna (Terminal) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.18 1+0 supporting frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.19 1+1 supporting frame for frequency diversity . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.20 1+1 Supporting frame for Hot stand-by . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.21 1+1 Supporting frame for Hot stand-by . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.22 IDU physical interfaces (16xE1 IDU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.5 IDU physical interfaces (32xE1 IDU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.6 IDU physical interfaces (1xE3 IDU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.7 IDU physical interfaces ( ETH IDU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.8 Network supervision . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.9 SRAL XD equipment: single terminal 1+0 configuration. . . . . . . . . . . . . . . . . . . . 5.4 SRAL XD equipment: dual terminal 2×(1+0) configuration. . . . . . . . . . . . . . . . . . 5.5 SRAL XD equipment: single terminal 1+1 H/S configuration (one antenna) . . . . 5.6 SRAL XD equipment: single terminal 1+1 PD configuration (one antenna) . . . . . 5.7 SRAL XD equipment: Repeater with tributary Add/Drop (A/D-RPT) configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.8 SRAL XD equipment: single terminal 1+0 configuration. . . . . . . . . . . . . . . . . . . . 5.9 SRAL XD equipment: single terminal 1+1 H/S configuration (one antenna) . . . 5.10 SRAL XD equipment: single terminal 1+1 PD configuration (one antenna) . . . . 5.11 SRAL XD equipment: single terminal 1+0 configuration. . . . . . . . . . . . . . . . . . . 5.12 SRAL XD equipment: single terminal 1+1 H/S configuration (one antenna) . . . 5.13 SRAL XD equipment: single terminal 1+1 PD configuration (one antenna) . . . . 5.14 SRAL XD equipment: single terminal 1+0 configuration. . . . . . . . . . . . . . . . . . . 5.15 SRAL XD equipment: single terminal 1+1 H/S configuration (one antenna) . . . 5.16 SRAL XD equipment: single terminal 1+1 PD configuration (one antenna) . . . . 5.17

IMC 0031METD Issue 1, June 2006 © 2006 Siemens AG

5

Siemens

Fig. 6.1 Fig. 6.2 Fig. 6.3 Fig. 6.4 Fig. 6.5 Fig. 6.6 Fig. 6.7 Fig. 6.8 Fig. 6.9 Fig. 6.10 Fig. 6.11 Fig. 6.12 Fig. 6.13 Fig. 6.14 Fig. 6.15 Fig. 6.16 Fig. 6.17 Fig. 6.18 Fig. 6.19 Fig. 6.20 Fig. 6.21 Fig. 6.22 Fig. 6.23 Fig. 6.24 Fig. 6.25 Fig. 6.26 Fig. 6.27 Fig. 6.28 Fig. 6.29 Fig. 6.30 Fig. 6.31 Fig. 6.32 Fig. 6.33 Fig. 7.1 Fig. 7.2 Fig. 7.3 Fig. 7.4 Fig. 7.5

6

SRAL XD (plug-in IDU)

16xE1 IDU block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.25 Data interface unit block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.26 Access Board payload block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.27 BaseBand Board payload block diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.28 1xE3 IDU block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.29 ETH IDU block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.30 Data interface unit block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.31 VLAN tag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.32 ODU’s functional block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.33 Tributary protection general block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.34 Rx general protection block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.35 (1+1) FD Tx section protection block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . 6.36 IDU front panel in (1+1 - 16xE1) configuration . . . . . . . . . . . . . . . . . . . . . . . . . 6.37 IDU front panel in (1+1 - 1xE3) configuration . . . . . . . . . . . . . . . . . . . . . . . . . . 6.38 IDU front panel in (1+1 - ETH ) configuration . . . . . . . . . . . . . . . . . . . . . . . . . . 6.39 IDU front panel in (1+1 - 32xE1) configuration . . . . . . . . . . . . . . . . . . . . . . . . . 6.40 Summary of the front panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.41 Base Band unit front panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.42 Controller unit front panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.43 1+1 FD: position of the switches and CH A and CH B LEDs switching on . . . . 6.44 1+1 FD: position of the switches and CH A and CH B LEDs switching on . . . . 6.45 1+1 FD: position of the switches and CH A and CH B LEDs switching on . . . . 6.46 1+1 FD: position of the switches and CH A and CH B LEDs switching on . . . . 6.47 1+1 Hot Standby: position of the switches and CH A and CH B LEDs switching on . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.48 1+1 Hot Standby: position of the switches and CH A and CH B LEDs switching on . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.49 1+1 Hot Standby: position of the switches and CH A and CH B LEDs switching on . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.50 1+1 Hot Standby: position of the switches and CH A and CH B LEDs switching on . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.51 ODU’s functional block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.52 “Vertical” polarization application (ODU “Normal Density” - ND and ODU “High Density enhanced HDe) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.53 “Vertical” polarization application (ODU “High Density” - HD) . . . . . . . . . . . . . . 6.54 “Horizontal” polarization application (ODU “Normal Density” - ND and ODU “High Density enhanced - HDe). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.55 “Horizontal” polarization application (ODU “High Density” - HD) . . . . . . . . . . . . 6.56 “Rx field measure” connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.57 Tributary protection general block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.7 Rx general protection block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.8 (1+1) FD Tx section protection block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.9 (1+1) HS Tx section protection block diagram. . . . . . . . . . . . . . . . . . . . . . . . . . 7.10 Tx protection in Hot-Standby configuration with one antenna . . . . . . . . . . . . . . 7.11

IMC 0031METD Issue 1, June 2006 © 2006 Siemens AG

SRAL XD (plug-in IDU)

Fig. 7.6 Fig. 7.7 Fig. 7.8 Fig. 7.9 Fig. 7.10 Fig. 7.11 Fig. 8.1 Fig. 8.2 Fig. 8.3 Fig. 8.4 Fig. 8.5 Fig. 8.6 Fig. 8.7 Fig. 9.1 Fig. 9.2 Fig. 9.3 Fig. 9.4 Fig. 9.5 Fig. 9.6 Fig. 9.7 Fig. 9.8 Fig. 9.9 Fig. 9.10 Fig. 9.11 Fig. 9.12 Fig. 9.13 Fig. 9.14 Fig. 9.15 Fig. 9.16 Fig. 9.17 Fig. 9.18 Fig. 9.19 Fig. 9.20 Fig. 9.21 Fig. 9.22 Fig. 9.23 Fig. 9.24 Fig. 9.25 Fig. 9.26 Fig. 9.27

Siemens

Tx protection in Frequency Diversity configuration (with two antennas) . . . . . . 7.12 Rx Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.13 Alarms of Hardware protection logic. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.14 Hardware protection logic architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.15 Alarms of Hitless protection logic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.16 Hitless Protection Logic Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.17 1+1 configuration of User channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.4 2x(1+0) configuration of User channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.5 Repeater configuration of User channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.6 1+1 configuration of R channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.7 2x(1+0) configuration of R channels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.8 1+1 configuration of D channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.9 2x(1+0) configuration of D channels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.10 16xE1 IDU - Primary Power Supply Connections . . . . . . . . . . . . . . . . . . . . . . . . 9.3 16xE1 IDU - ODU connections (connector coax. type SMA) . . . . . . . . . . . . . . . . 9.4 16xE1 IDU - 2 Mbit/s 120 ohm (Sub-D) from 1 to 8 Tributary Connections . . . . . 9.5 16xE1 IDU - 2 Mbit/s 120 ohm (Sub-D) from 9 to 16 Tributary Connections . . . . 9.6 16xE1 IDU - 2 Mbit/s 75 ohm (Sub-D) from 1 to 8 Tributary Connections . . . . . . 9.7 16xE1 IDU - 2 Mbit/s 75 ohm (Sub-D) from 9 to 16 Tributary Connections . . . . . 9.8 16xE1 IDU - 2 Mbit/s (75 ohm coax.) from 1 to 16 Tributary Connections . . . . . . 9.9 16xE1 IDU - 2 Mbit/s (120 ohm LEMO) from 1 to 16 Tributary Connections . . . 9.10 16xE1 IDU - Alarm connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.11 16xE1 IDU - 64 kbit/s (V.11) service channel connnection: USER/Dext (USER 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.12 16xE1 IDU - 64 kbit/s (V.11) service channel connnection: USER/Dext (USER 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.13 16xE1 IDU - (CH1 and CH2) 64 kbit/s (V11) service channel connnection . . . . 9.14 16xE1 IDU - Supervision connections (Q LAN - V LAN) . . . . . . . . . . . . . . . . . . 9.15 16xE1 IDU - Connection example (Q LAN - V LAN) . . . . . . . . . . . . . . . . . . . . . 9.16 16xE1 IDU - V-BUS Connection ( with Controller P/N 634-001/74) . . . . . . . . . . 9.17 16xE1 IDU - LCT connection (RS 232) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.18 1xE3 IDU - Primary Power Supply Connections . . . . . . . . . . . . . . . . . . . . . . . . 9.19 1xE3 IDU - ODU connections (connector coax. type SMA) . . . . . . . . . . . . . . . . 9.20 1xE3 IDU - 34 Mbit/s tributary connections (75 ohm coax.) . . . . . . . . . . . . . . . . 9.21 1xE3 IDU - 2 Mbit/s WST Signal connections (75 ohm coax.) . . . . . . . . . . . . . . 9.22 1xE3 IDU - Alarm connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.23 1xE3 IDU - 64 kbit/s (V.11) service channel connection: USER/Dext (USER 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.24 1xE3 IDU - 64 kbit/s (V.11) service channel connection: USER/Dext (USER 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.25 1xE3 IDU - (CH1 and CH2) 64 kbit/s (V11) service channel connection . . . . . . 9.26 1xE3 IDU - Supervision connections (Q LAN - V LAN) . . . . . . . . . . . . . . . . . . . 9.27 1xE3 IDU - Connection example (Q LAN - V LAN) . . . . . . . . . . . . . . . . . . . . . . 9.28 1xE3 IDU - V-BUS Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.29

IMC 0031METD Issue 1, June 2006 © 2006 Siemens AG

7

Siemens

Fig. 9.28 Fig. 9.29 Fig. 9.30 Fig. 9.31 Fig. 9.32 Fig. 9.33 Fig. 9.34 Fig. 9.35 Fig. 9.36 Fig. 9.37 Fig. 9.38 Fig. 9.39 Fig. 9.40 Fig. 9.41 Fig. 9.42 Fig. 9.43 Fig. 9.44 Fig. 9.45 Fig. 9.46 Fig. 9.47 Fig. 9.48 Fig. 9.49 Fig. 9.50 Fig. 9.51 Fig. 9.52 Fig. 9.53 Fig. 10.1 Fig. 10.2 Fig. 10.3 Fig. 10.4 Fig. 10.5 Fig. 10.6 Fig. 10.7 Fig. 10.8 Fig. 11.1 Fig. 12.1 Fig. 12.2 Fig. 12.3 Fig. 13.1 Fig. 13.2 Fig. 13.3

8

SRAL XD (plug-in IDU)

1xE3 IDU - LCT connection (RS 232) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.30 ETH IDU - Primary Power Supply Connections. . . . . . . . . . . . . . . . . . . . . . . . . 9.31 ETH IDU - ODU connections (connector coax. type SMA) . . . . . . . . . . . . . . . . 9.32 ETH IDU - 2 Mbit/s 75 ohm (Sub-D) from 1 to 8 Tributary Connections . . . . . . 9.33 ETH IDU - 2 Mbit/s 120 ohm (Sub-D) from 1 to 8 Tributary Connections . . . . . 9.34 ETH IDU - 10/100 BaseT Ethernet Lan Ports (RJ45) . . . . . . . . . . . . . . . . . . . . 9.35 ETH IDU - Alarm connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.36 ETH IDU - 64 kbit/s (V.11) service channel connection: USER/Dext (USER 1) 9.37 ETH IDU - 64 kbit/s (V.11) service channel connection: USER/Dext (USER 2) 9.38 ETH IDU - (CH1 and CH2) 64 kbit/s (V11) service channel connection . . . . . . 9.39 ETH IDU - Supervision connections (Q LAN - V LAN) . . . . . . . . . . . . . . . . . . . 9.40 ETH IDU - Connection example (Q LAN - V LAN). . . . . . . . . . . . . . . . . . . . . . . 9.41 ETH IDU - V-BUS Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.42 ETH IDU - LCT connection (RS 232). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.43 Primary Power Supply Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.44 ODU connections (connector coax. type SMA) . . . . . . . . . . . . . . . . . . . . . . . . . 9.45 2 Mbit/s 75 ohm (MiniRJ21) from 1 to 8 / 9 to 16 / 17 to 24 / 25 to 32 Tributary Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.46 2 Mbit/s 120 ohm (MiniRJ21) from 1 to 8 / 9 to 16 / 17 to 24 / 25 to 32 Tributary Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.47 Alarm connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.48 64 kbit/s (V.11) service channel connnection: USER/Dext (USER 1) . . . . . . . . 9.50 64 kbit/s (V.11) service channel connnection: USER/Dext (USER 2) . . . . . . . . 9.51 (CH1 and CH2) 64 kbit/s (V11) service channel connnection . . . . . . . . . . . . . . 9.52 Supervision connections (Q LAN - V LAN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.53 Connection example (Q LAN - V LAN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.54 V-BUS Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.55 V-BUS Connection example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.56 IDU Key position (16xE1 Tributary unit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.6 IDU Key position (1xE3 Tributary unit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.7 IDU Key position (ETH Tributary unit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.8 IDU Key position (32xE1 Tributary unit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.9 LEDs status in the normal operating conditions of a 1+0/1+1 system (16xE1) 10.10 LEDs status in the normal operating conditions of a 1+0/1+1 system (1xE3) . 10.11 LEDs status in the normal operating conditions of a 1+0/1+1 system (ETH) . 10.12 LEDs status in the normal operating conditions of a 1+0/1+1 system (32xE1) 10.13 Tributary loop-back . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.2 IDU assembly LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.12 Ethernet tributary unit LAN Ports LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.13 Flow chart No. 1 - Intervention procedure because of failure . . . . . . . . . . . . . 12.14 ETSI Block diagram of Tx RF side. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.32 Mask of the RF signal for 7 to 38 GHz ODU ND according to the traffic capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.33 ETSI Block diagram of Rx RF side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.34

IMC 0031METD Issue 1, June 2006 © 2006 Siemens AG

SRAL XD (plug-in IDU)

Siemens

Fig. 13.4 ETSI Block diagram of Tx RF side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.35 Fig. 13.5 Mask of the RF signal for 7 to 38 GHz ODU (HP mode) according to the traffic capacity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.36 Fig. 13.6 Mask of the RF signal for 23, 26, 28 and 38 GHz ODU (HD mode) according to the traffic capacity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.37 Fig. 13.7 Mask of the RF signal for 7, 8,15 and 18 GHz ODU (HD mode) according to the traffic capacity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.38 Fig. 13.8 ETSI Block diagram of Rx RF side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.39 Fig. 13.9 ETSI Block diagram of Tx RF side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.40 Fig. 13.10Mask of the RF signal for 18, 23 and 38 GHz ODU (ND mode) according to the traffic capacity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.41 Fig. 13.11Mask of the RF signal for 18 Ghz ODU (HD mode) or 23, 38 GHz ODU (HD mode) according to the traffic capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.42 Fig. 13.12ETSI Block diagram of Rx RF side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.43 Fig. 13.13Shape of 2 Mbit/s tributary interface output signal. . . . . . . . . . . . . . . . . . . . . . 13.44 Fig. 13.14Shape of 34 Mbit/s tributary interface output signal. . . . . . . . . . . . . . . . . . . . . 13.45 Fig. 13.15Temperature/humidity climatic diagram for IDU. . . . . . . . . . . . . . . . . . . . . . . . 13.46 Fig. 13.16Temperature/humidity climatic diagram for ODU. . . . . . . . . . . . . . . . . . . . . . . 13.47 Fig. 13.17Temperature/humidity climatic diagram for IDU-ODU storage . . . . . . . . . . . . 13.48 Fig. 13.18Braided coaxial cable - IDU/ODU tipical connection . . . . . . . . . . . . . . . . . . . . 13.49 Fig. 13.191/4” coaxial cable - IDU/ODU tipical connection . . . . . . . . . . . . . . . . . . . . . . . 13.50 Fig. 13.201/4” coaxial cable - Connection on IDU side . . . . . . . . . . . . . . . . . . . . . . . . . . 13.51

IMC 0031METD Issue 1, June 2006 © 2006 Siemens AG

9

Siemens

10

SRAL XD (plug-in IDU)

IMC 0031METD Issue 1, June 2006 © 2006 Siemens AG

SRAL XD (plug-in IDU)

Siemens

LIST OF TABLES Tab. 3.1 System configurations for SRAL XD equipment . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2 Tab. 5.1 Configuration summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.3 Tab. 6.1 Plug-in 16xE1 IDU composition P/N 732-101/61 (Controller unit P/N 634-001/73 equipped) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.15 Tab. 6.2 Plug-in 16xE1 IDU composition P/N 732-101/61 (Controller unit P/N 634-001/74 equipped) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.16 Tab. 6.3 Plug-in 1xE3 IDU composition P/N 732-101/61 . . . . . . . . . . . . . . . . . . . . . . . . . 6.17 Tab. 6.4 Plug-in ETH IDU composition P/N 732-101/61. . . . . . . . . . . . . . . . . . . . . . . . . . 6.18 Tab. 6.5 Plug-in 32xE1 IDU composition P/N 732-101/62 . . . . . . . . . . . . . . . . . . . . . . . . 6.19 Tab. 6.6 Summary of the front panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.20 Tab. 8.1 User channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.2 Tab. LCT connector (RS 232). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.18 Tab. 10.1KEY alarms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.3 Tab. 12.1List of spare parts - 16xE1 IDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.6 Tab. 12.2List of spare parts - ETH IDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.6 Tab. 12.3List of spare parts - 1xE3 IDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.6 Tab. 12.4List of spare parts - 32xE1 IDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.7 Tab. 12.5ODU “HD/HP” 7 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.7 Tab. 12.6ODU “HD/HP” 8 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.7 Tab. 12.7ODU “HD/HP” 15 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.7 Tab. 12.8ODU “HD/HP” 18 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.7 Tab. 12.9ODU “HD/HP” 23 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.7 Tab. 12.10ODU “HD/HP” 26 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.8 Tab. 12.11ODU “HD/HP” 28 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.8 Tab. 12.12ODU “HD/HP” 38 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.8 Tab. 12.13ODU “HD/HP Low Power” 38 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.8 Tab. 12.14ODU “ND” 7 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.8 Tab. 12.15ODU “ND” 8 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.8 Tab. 12.16ODU “ND” 13 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.9 Tab. 12.17ODU “ND” 15 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.9 Tab. 12.18ODU “ND” 18 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.9 Tab. 12.19ODU “ND” 23 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.9 Tab. 12.20ODU “ND” 26 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.9 Tab. 12.21ODU “ND” 28 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.9 Tab. 12.22ODU “ND” 38 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.9 Tab. 12.23ODU “HDe” 18 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.10 Tab. 12.24ODU “HDe” 23 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.10 Tab. 12.25ODU “HDe” 38 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.10 Tab. 12.26ODU “HDe Low Power” 38 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.10 Tab. 13.1Antenna P/N . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.23

IMC 0031METD Issue 1, June 2006 © 2006 Siemens AG

11

Siemens

SRAL XD (plug-in IDU)

Tab. 13.2Construction characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tab. 13.3Mechanical characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tab. 13.4Range of temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tab. 13.5Electrical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tab. 13.6Attenuation, (dB/100) Standard conditions: VSWR 1.0; ambient temperature 24°C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tab. 13.7Average Power Rating, kW Standard conditions: VSWR 1.0; ambient temperature 40°C; inner conductor temperature 100°C; . . . . . . . . . . . . . . . . . Tab. 13.8Andrew set. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tab. 13.9RFS-Kabelmetal set. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tab. 13.10Construction characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tab. 13.11Mechanical characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tab. 13.12Range of temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tab. 13.13Electrical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tab. 13.14Attenuation, (dB/100m) Standard conditions: VSWR 1.0; ambient temperature 24°C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tab. 13.15Average Power Rating, kW Standard conditions: VSWR 1.0; ambient temperature 40°C; inner conductor temperature 100°C; . . . . . . . . . . . . . . . . . Tab. RF signal attenuation limit values (23, 26, 28 and 38 GHz - HD) . . . . . . . . . . Tab. RF signal attenuation limit values (7, 8, 15 and 18 GHz - HD) . . . . . . . . . . . .

12

13.24 13.24 13.24 13.25 13.25 13.26 13.27 13.27 13.28 13.28 13.28 13.29 13.30 13.31 13.37 13.38

IMC 0031METD Issue 1, June 2006 © 2006 Siemens AG

SRAL XD (plug-in IDU)

1

Safety Rules

1.1

General

Siemens

This document contains all the safety rules and the correct precautions to be followed during operations on the equipment to avoid injuries to personnel and/or damages to the equipment components.

1.2

Safety rules

The equipment complies with the 89/336/EEC European specification. The equipment is preconfigured for supply from station batteries (-48 VDC ± 20%); then follow the on force specifications for low voltage supplied equipment's.

1.2.1

Electrical safety

1.2.1.1

Warnings for the electrical safety

The equipment complies with the CEI EN 60950-1 safety specifications. The equipment must be installed, started up, managed and repaired only by properly trained personnel. ●

Before supplying the equipment, it is necessary to complete the wiring of the connections to the protection ground, the insertion of all the units and/or modules provided for the requested configuration and also the connection of all the necessary connectors.



The connection to the protection ground must not be removed or damaged.

1.2.1.2

Waste equipment management

The radio equipment at the end of its life can be classified as “16 02 14 equipment out of use different from the equipment listed in 16 02 09 to 16 02 13” according to the dangerous waste list determined in article 1 para. 4 of Government Recc. 91/689/EEC on the dangerous waste updated in Recc. 2001/118/EC.

IMC 0031METD Issue 1, June 2006 © 2006 Siemens AG

1-1

Siemens

SRAL XD (plug-in IDU)

INFORMATION TO USER (FOR ITALIAN MARKET ONLY) According to the art. 13 of the legislative decree, D.Lgs nr. 151 of the 25th of july 2005. "adopting directives 2002/95/CE, 2002/96/CE e 2003/108/CE, releted on the restriction of the use of certain hazardous substances in electrical and electronic equipment, and on disposal of electrical and electronic waste". The crossed-out bin symbol on equipment, means that the product, at the end of its useful life, must be disposed separately from the municipal waste. User should return it to the municipalities collection system or to the ratailers if you buy a new equivalent product. Differentiated waste of old appliances will result in recycling, treatment and environmental compatible disposal, which will help to prevent potential negative consequences on the environment and human health and consequently the reuse of renewable raw material The misdemenour of the disposal will lead to financial penalties as defined in artt. 50 onwards, of the legislative decree nr. 22 of the 5th of february 1997.

The equipment does not include:

1-2



Cadmium



Mercury



Asbestos



Radioactive materials



PCB



Berillium

IMC 0031METD Issue 1, June 2006 © 2006 Siemens AG

SRAL XD (plug-in IDU)

1.2.2

Siemens

External operations

Some other operations involving danger conditions are the ones executed outside during the equipment installation and starting up phase. During the execution of such operations, it is necessary to follow strictly the safety rules listed here below: ●

During installation, while the antenna and/or the external supporting-frame for rod are lifted, it is strictly forbidden to stay or to pass in the underlying area. Such an area must be properly restricted or signalled according to the on force rules.



For the external operations to be executed on the antenna, on the frame and on the ODU, all the necessary safety rules against accidental fallings of the operators must be respected, according to the on force rules. For example, it is necessary to use protection fences and belts.



During the equipment starting up phase, the operators must not be in front of the antenna. If one of the above mentioned safety rules is not respected, some injuries to the personnel can be caused.

IMC 0031METD Issue 1, June 2006 © 2006 Siemens AG

1-3

SRAL XD (plug-in IDU)

Siemens

1.3

ESDS Precautions The ESDS (Electro Static Discharge Sensitive) electronic devices can be partially or permanently damaged by the static electricity that is commonly present in the operating environment. The main ESDS devices are: –

CMOS components



Large Scale Integration components in MOS technology



SAW (Surface Acoustic Wave) components



Operational amplifiers with MOS/FET inputs



MOS/FET components and arrays



Microwave semiconductors and microcircuits at frequencies > 1 GHz

Modules containing ESDS devices are identified by following adhesive labels:

In order avoid any damage while handling the modules, the user should wear an antistatic elastic bracelet, grounded by means a spiral cord. Those modules that are mounted on the equipment (faulty or spare parts) shall be stores in their original antistatic package marked by the labels above shown.

1-4

IMC 0031METD Issue 1, June 2006 © 2006 Siemens AG

SRAL XD (plug-in IDU)

2

Glossary

2.1

List of abbreviations

Siemens

A/D-RPT Add/Drop Repeater AC Alternating Current ACI Adjacent Channel Interference AGC Automatic Gain Control ALM Alarm ATPC Automatic Transmit Power Control AUX Auxiliary BB Base Band BER Bit Error Rate BOL Beginning Of Life BSC Basic Station Center BTS Basic Terminal Station

IMC 0031METD Issue 1, June 2006 © 2006 Siemens AG

2-1

Siemens

SRAL XD (plug-in IDU)

CCI Co-Channel Interference CH Channel CMD Command CPM Continuous Phase Modulation CW Continuous Wave D/A Digital/Analog DC Direct Current DCE Data Communication Equipment DEM Demodulator DTE Data Terminal Equipment DTMF Dual Tone Multi Frequency EM ElectroMagnetic EN Enable EOL End Of Life

2-2

IMC 0031METD Issue 1, June 2006 © 2006 Siemens AG

SRAL XD (plug-in IDU)

Siemens

EOW Engineering Order Wire E&M “Ear and Mouth” ESDS Electro Static Discharge Sensitive ETH Ethernet EXT External FD Frequency Diversity FEC Forward Error Corrector GA Gate Array GND Ground H High H/S Hot-Standby HD High Density HDB3 High Density Bipolar 3 HDLC High Data Link Control

IMC 0031METD Issue 1, June 2006 © 2006 Siemens AG

2-3

Siemens

SRAL XD (plug-in IDU)

HL Hitless HP High Performance HW Hardware I/O Input/Output IC Integrated Circuit ID Identifier IDU Indoor Unit IF Intermediate Frequency IN Input IND Indicative INT Internal ITMN Installation Test Manual L Low LAN Local Area Network

2-4

IMC 0031METD Issue 1, June 2006 © 2006 Siemens AG

SRAL XD (plug-in IDU)

Siemens

LCT Local Craft Terminal LSI Large Scale Integration MEM Memorization MOD Modulator MSC Mobile Service switching Center MTTR Mean Time To Repair ND Normal Density NE Network Element NRZ Not Return-to-Zero NURG Not Urgent ODU Outdoor Unit OMC Operation & Maintenance Center OSI Open System Interconnection OUT Output

IMC 0031METD Issue 1, June 2006 © 2006 Siemens AG

2-5

Siemens

SRAL XD (plug-in IDU)

OW Overflow PC Personal Computer PD Polarization Diversity PDH Plesiochronous Digital Hierarchy PLL Phase Lock Loop QAM Quadrature Amplitude Modulation RF Radio Frequency RIEP Recapitulary RPT Repeater RS Reed Solomon Rx Reception S/I Sensitivity/Interference SLIC Subscriber Line Circuit SRAL Low capacity Siemens Radio Access

2-6

IMC 0031METD Issue 1, June 2006 © 2006 Siemens AG

SRAL XD (plug-in IDU)

Siemens

SW Software TCM Trellis Code Modulation TCP/IP Transmission Control Protocol/Internet Protocol TMN Telecommunications Management Network TRIB Tributary TS Service telephone Tx Transmission UHF Ultra High Frequency URG Urgent VCO Voltage Controlled Oscillator

IMC 0031METD Issue 1, June 2006 © 2006 Siemens AG

2-7

Siemens

2-8

SRAL XD (plug-in IDU)

IMC 0031METD Issue 1, June 2006 © 2006 Siemens AG

SRAL XD (plug-in IDU)

3

SYSTEM DESCRIPTION

3.1

SRAL XD system

Siemens

In this Training Manual is described the SRAL XD system operating at 7 GHz, 8 GHz, 13 GHz, 15 GHz, 18 GHz, 23 GHz, 26 GHz, 28 GHz and 38 GHz with the plug-in IDU only with the following traffic capacity: ●

2×E1



4×E1



8×E1



16×E1



32xE1



1xE3 + 1WST



4xEthernet Interfaces (10/100 BaseT) + 8xE1

The 2 Mbit/s capacity, having the channel arrangement like the one of 2x2 Mbit/s capacity, is derived from 2x2 Mbit/s option.

3.2

System building

Fig. 3.1 shows the SRAL XD (with 16xE1 IDU) equipment block diagram while Fig. 3.3 shows the SRAL XD (with 32xE1 IDU) equipment block diagram, Fig. 3.3 shows the SRAL XD (with 1xE3 IDU) equipment block diagram, Fig. 3.4 shows the SRAL XD (with the 4 Ethernet + 8xE1 IDU) equipment block diagram. The equipment has been realized by physically subdividing it into two assemblies: one for outdoor installation (ODU) and one for indoor installation (IDU). This subdivision allows: ●

the RF losses, due to the interconnection between ODU and the antenna, to be minimized



a common IDU, for all the applications to be realized.

According to the configurations, one or two ODUs can be equipped. The connection between IDU and ODU is made through a single coaxial cable. It is possible to use antennas with diameter dependently of the hop lenght to be realized. The ODU is available in two versions:

IMC 00031METD Issue 1, June 2006 © 2006 Siemens AG

3-1

SRAL XD (plug-in IDU)

Siemens



Normal Density (ND) able to perform traditional channel arrangements 2/4/8/16xE1/1xE3 in 3.5/7/14/28/28 MHz via 4 CPM modulation format.



High Density/High Performance (HD/HP) able to perform both High Density arrangements (8/16xE1/1xE3 in 7/14/14 MHz), via 16 TCM modulation format, and Normal Density arrangements (2/4/8/16xE1/1xE3 in 3.5/7/14/28/28 MHz), via 4 QAM modulation format. Normal Density arrangement performed by ODU HD/HP is named High Performance since it provides improved system gain in comparison to ODU ND.



High Density enhanced (HDe) able to perform both High Density arrangements (8/16xE1/32xE1 in 7/14/28 MHz), via 16 TCM modulation format, and Normal Density arrangements (4/8/16xE1 in 7/14/28 MHz), via 4 QAM modulation format.

3.3

System configurations

For the SRAL XD equipment the configurations (system types) are provided as listed in the following table. Tab. 3.1

System configurations for SRAL XD equipment

System type 1+0 2×(1+0) A/D-RPT 1+1 PD 1+1 FD 1+1 H/S 1+1 PD, FD

Denomination 1+0 single terminal 2×(1+0) dual terminal or Add/Drop repeater with 2 antennas 1+1 single terminal system with 1 antenna

1+1 single terminal system with 2 antennas

Ref.

Note

Fig. 3.5 Fig. 3.6 and Fig. 3.7

1

Fig. 3.11, Fig. 3.10, Fig. 3.12 and Fig. 3.13 Fig. 3.8 and Fig. 3.9

1) Configurations not available for 1xE3 capacity and 4xLan+8xE1 capacity.

3.4

Network Topologies

Possible topologies of the “SRAL XD” equipment are shown in UMN Manual.

3.5

IDU-ODU Interconnection

The interconnection between the IDU (with 16x2 BB unit) and the ODU (Fig. 3.5 to Fig. 3.14) consists of only one two-way line transporting one composite signal comprising the 51.84 Mbit/s IDU-ODU stream and of the ODU power supply voltage.

3-2

IMC 00031METD Issue 1, June 2006 © 2006 Siemens AG

SRAL XD (plug-in IDU)

Siemens

The interconnection between the IDU (with 32x2 BB unit) and the ODU consists of only one two-way line transporting one composite signal comprising the 155.520 Mbit/s IDU-ODU stream and of the ODU power supply voltage.

3.5.1

51.84 Mbit/s or 155.520 Mbit/s signal

With regard to the transmission/reception of the 51.84 or 155.520 Mbit/s stream, the IDU-ODU link consists of an active hybrid. The active hybrid on the transmission path allows to forward the 51.84 or 155.520 Mbit/s stream to the output i.e., either towards the ODU or towards the IDU. Afterwards, by means of the properly connected operational amplifiers the cited signal will be suppressed on the receive side (i.e., towards the unit proper). The signal that has been received from the ODU (or from the IDU) is sent to the Receive Circuits via the active hybrid. A 128 kbit/s auxiliary channel is present on the 51.84 or 155.520 Mbit/s stream connecting the IDU and the ODU. The channel also transports all the data necessary for the equipment to operate properly (alarms, data channel, etc.).

3.5.2

ODU Power Supply

The IDU-ODU interconnection cable also transports the auxiliary DC voltage, required to power the ODU, which is supplied by the corresponding BB 16xE1/32xE1/1xE3 unit of the IDU. In this unit are also present the soft-start circuits, the current limitation circuit and the generation of the open cable alarm or short-circuited cable alarm.

3.6

Supporting frame

3.6.1

1+0 supporting frame

The 1+0 supporting frame (Fig. 3.15) consists of a mechanical structure, and relevant waveguide accessories, suitable for pole or wall mounting of the Outdoor Unit in 1+0 configuration. From an electrical point of view the frame is a passive device (i.e. waveguide section) that provides interconnection between its two ports with negligible insertion loss. The 1+0 supporting frame is used (quantity: 2) also in 1+1 and 2x(1+0) configurations with 2 antennas.

IMC 00031METD Issue 1, June 2006 © 2006 Siemens AG

3-3

SRAL XD (plug-in IDU)

Siemens

3.6.2

1+1 Supporting frame for frequency diversity

The 1+1 supporting frame from frequency diversity (Fig. 3.16) consists of a mechanical structure, and relevant waveguide accessories, suitable for pole or wall mounting of the Outdoor Unit in 1+1 Frequency Diversity configuration. The two ODU parts are interconnected to the antenna port through a circulator. Both the ODU’s transmit at the same time, delivering the signal on two RF channels at different frequecies on the same polarisation.

3.6.3

1+1 Supporting frame for Hot stand-by with integrated antenna

The 1+1 supporting frame for Hot Stand-by (Fig. 3.17) consists of a mechanical structure, and relevant waveguide accessories, suitable for pole or wall mounting of the Outdoor Unit in 1+1 HSBY (Hot Stand-by) unbalanced or balanced configuration. From an electrical point of view the 1+1 frame is a balanced or unbalanced coupler. The signal incoming from the antenna port is split unbalanced-wise the two ODU’s.

3.6.4

1+1 Supporting frame for Hot stand-by with independent antenna

The 1+1 supporting frame for Hot Stand-by (Fig. 3.18) consists of a mechanical structure, and relevant waveguide accessories, suitable for pole or wall mounting of the Outdoor Unit in 1+1 HSBY (Hot Stand-by) unbalanced or balanced configuration. From an electrical point of view the 1+1 frame is a balanced or unbalanced coupler. The signal incoming from the antenna port is split unbalanced-wise the two ODU’s.

3-4

IMC 00031METD Issue 1, June 2006 © 2006 Siemens AG

SRAL XD (plug-in IDU)

Fig. 3.1

Siemens

SRAL XD equipment block diagram (with 16xE1 IDU) Integrated antenna

V-BUS(*) Interface F Interface Control and supervision signals and channels

V-LAN Interface Q-LAN Interface

IDU-ODU interconnection (coaxial cable)

ALM Interface IDU E1 Interfaces USER-1 Interface USER-2 Interface

ODU

Tributary and services signals (payload)

PS Interface

IDU-CABLE interface

ODU-CABLE interface

RSSI interface

ANTENNA interface

RF interface

(*) This interface is available with Controller (P/N 634-001/74) only

IDU Basic functions:

• • • •



System interfacing to external world Baseband digital signal processing IDU-ODU cable interface management (from/to ODU) Supervision and configuration/management of the equipment Equipment’s power supply management

ODU Basic functions:

• • • • • •

IMC 00031METD Issue 1, June 2006 © 2006 Siemens AG

IDU-ODU cable interface management Modulation of baseband digital signal (from IDU) Demodulation of the received RF signal (to IDU) Supervision and configuration/management of the ODU Management of comm. channel from/to IDU CONTROLLER RSSI Interface (Received Signal Strength Indication) to measure the RF received signal

3-5

SRAL XD (plug-in IDU)

Siemens

Fig. 3.2

SRAL XD equipment block diagram (with 32xE1 IDU) Integrated antenna

V-BUS Interface F Interface V-LAN Interface Q-LAN Interface ALM Interface E1 Interfaces 32

USER-1 Interface USER-2 Interface PS Interface

Control and supervision signals and channels IDU Tributary and services signals (payload)

IDU-ODU interconnection (coaxial cable)

IDU-CABLE interface

ODU

ODU-CABLE interface

IDU Basic functions:

• • • •



System interfacing to external world Baseband digital signal processing IDU-ODU cable interface management (from/to ODU) Supervision and configuration/management of the equipment Equipment’s power supply management

ANTENNA interface

RF interface

ODU Basic functions:

• • • •

• •

3-6

RSSI interface

IDU-ODU cable interface management Modulation of baseband digital signal (from IDU) Demodulation of the received RF signal (to IDU) Supervision and configuration/management of the ODU Management of comm. channel from/to IDU CONTROLLER RSSI Interface (Received Signal Strength Indication) to measure the RF received signal

IMC 00031METD Issue 1, June 2006 © 2006 Siemens AG

SRAL XD (plug-in IDU)

Fig. 3.3

Siemens

SRAL XD equipment block diagram (with 1xE3 IDU) Integrated antenna

V-BUS Interface F Interface Control and supervision signals and channels

V-LAN Interface Q-LAN Interface

IDU-ODU interconnection (coaxial cable)

ALM Interface IDU E3 Interface WST Interface USER-1 Interface USER-2 Interface

ODU

Tributary and services signals (payload)

PS Interface

IDU-CABLE interface

ODU-CABLE interface

IDU Basic functions:

• • • •



System interfacing to external world Baseband digital signal processing IDU-ODU cable interface management (from/to ODU) Supervision and configuration/management of the equipment Equipment’s power supply

IMC 00031METD Issue 1, June 2006 © 2006 Siemens AG

RSSI interface

ANTENNA interface

RF interface

ODU Basic functions:

• • • • • •

IDU-ODU cable interface management Modulation of baseband digital signal (from IDU) Demodulation of the received RF signal (to IDU) Supervision and configuration/management of the ODU Management of comm. channel from/to IDU CONTROLLER RSSI Interface (Received Signal Strength Indication) to measure the RF received signal

3-7

SRAL XD (plug-in IDU)

Siemens

Fig. 3.4

SRAL XD equipment block diagram (with ETH IDU)

V-BUS Interface

Control and supervision signals and channels

F Interface V-LAN Interface Q-LAN Interface ALM Interface ETH Interfaces 4

E1 Interfaces 8

USER-1 Interface USER-2 Interface PS Interface

Integrated antenna IDU-ODU interconnection (coaxial cable)

IDU Tributary and services signals (payload)

IDU-CABLE interface

ODU

ODU-CABLE interface

IDU Basic functions:

• • • •



System interfacing to external world Baseband digital signal processing IDU-ODU cable interface management (from/to ODU) Supervision and configuration/management of the equipment Equipment’s power supply management

ODU Basic functions:

• • • •

• •

3-8

RSSI RF interface ANTENNA interface interface

IDU-ODU cable interface management Modulation of baseband digital signal (from IDU) Demodulation of the received RF signal (to IDU) Supervision and configuration/management of the ODU Management of comm. channel from/to IDU CONTROLLER RSSI Interface (Received Signal Strength Indication) to measure the

IMC 00031METD Issue 1, June 2006 © 2006 Siemens AG

SRAL XD (plug-in IDU)

Fig. 3.5

Siemens

1+0 system with 1 integrated antenna (Terminal)

16xE1 / 32xE1 / ETH IDU

Tx5

Tx1

Tx9

Rx5

Rx1

Tx13

Rx9

ODU CABLE

s

Rx13

USER/Dext

I

USER/Dext

C H

C H

A

B

O D

C B

'

U

L

PS

SRAL XD Q-LAN

ALMs

V-LAN LCT

0

T E S

M N /

C / M

T

W

J

'

µ TEL

4 WIRE + E&M ______________________ EXP2 I

I

LINE STATUS _I I _II

Ä

OR

EOW

V.11 LINE1

PWR- 48V

LCT

-

1xE3 IDU

Tx

Tx

Rx

Rx

ODU CA BLE ODU CABLE

s 34 Mb/s

LINE STATUS _I I _II

T

M

C

E S T

N / W

/ M J

U

'

EOW

V.11 LINE1

Ä

O D

L

V-BUS

USER/Dext '

µ TEL

C B

B

Vbattery

V-LAN

LCT

PWR- 48V

C H

A

CAUTION

Q-LAN

USER/Dext

C H

PS

SRAL XD

2 Mb/s WST

ALMs

I

4 WIRE + E&M ______________________ EXP2 I

External EOW (OPTIONAL)

LCT

-

IMC 00031METD Issue 1, June 2006 © 2006 Siemens AG

3-9

SRAL XD (plug-in IDU)

Siemens

Fig. 3.6

1+0 system with 1 independent antenna (Terminal)

16xE1 / 32xE1 / ETH IDU

Tx5

Tx1

Tx9

Rx5

Rx1

Tx13

Rx9

s

Rx13

I

USER/Dext

LCT

µ TEL

I

LINE STATUS _I I _II

Ä

OR

EOW

V.11 LINE1

PWR- 48V

V-LAN

0

4 WIRE + E&M ______________________ EXP2 I

USER/Dext

PS

SRAL XD Q-LAN

ALMs

LCT

-

1xE3 IDU

Tx

Rx

Tx

Rx

ODU CABLE

s

34 Mb/s

C

C

C

O

H A

H B

B L

D U

' PS

SRAL XD

2 Mb/s WST Q-LAN

V-LAN

V-BUS LCT

ALMs

USER/Dext

USER/Dext '

µ TEL

Ä

LINE STATUS _I I _II

M N / W

C / M J

EOW

V.11 LINE1

PWR- 48V

T E S T

I

4 WIRE + E&M ______________________ EXP2 I

External EOW (OPTIONAL)

LCT

-

3-10

IMC 00031METD Issue 1, June 2006 © 2006 Siemens AG

SRAL XD (plug-in IDU)

Fig. 3.7

Siemens

2x(1+0) dual terminal system, Repeater A/D with 2 integrated antennas

16xE1 IDU

Tx5

Tx1

Tx9

Rx5

Rx1

Tx13

Rx9

ODU CABLE

s

Rx13

USER/Dext

I

USER/Dext

C H A

C H B

C B L

O D U

C H A

C H B

C B L

O D U

'

PS

SRAL XD Q-LAN

ALMs

V-LAN LCT

0

'

T E S

M N /

C / M

T

W

J

ODU CABLE

'

PS

EOW

µ TEL

Ä

LINE STATUS _I I _II

I

4 WIRE + E&M ______________________ EXP2 I

V.11 LINE1

PWR- 48V

LCT

-

External EOW (OPTIONAL)

IMC 00031METD Issue 1, June 2006 © 2006 Siemens AG

3-11

SRAL XD (plug-in IDU)

Siemens

Fig. 3.8

2x(1+0) dual terminal system, Repeater A/D with 2 independent antennas

16xE1 IDU

Tx1

Tx5

Rx1

Tx9

Rx5

Tx13

Rx9

ODU CABLE

s

Rx13

USER/Dext

I

USER/Dext

C H A

C H B

C B L

O D U

C H A

C H B

C B L

O D U

'

PS

SRAL XD Q-LAN

ALMs

V-LAN LCT

0

'

T E S

M N /

C / M

T

W

J

ODU CABLE

'

PS

3-12

PWR- 48V µ TEL

Ä

LINE STATUS _I I _II

I

4 WIRE + E&M ______________________ EXP2 I

External EOW (OPTIONAL)

EOW

V.11 LINE1

LCT

-

IMC 00031METD Issue 1, June 2006 © 2006 Siemens AG

SRAL XD (plug-in IDU)

Fig. 3.9

Siemens

1+1 FD, PD system with 2 integrated antennas (Terminal)

16xE1 / 32xE1 / ETH IDU

Tx5

Tx1

Tx9

Rx5

Rx1

Tx13

Rx9

s

Rx13

I

USER/Dext

LCT

µ TEL

I

LINE STATUS _I I INS _II

Ä'

LCT

OR

EOW ______

V.11 LINE1

PWR- 48V

V-LAN

0

4 WIRE + E&M ______________________ EXP1 EXP2 I

USER/Dext

PS

SRAL XD Q-LAN

ALMs

V.11 LINE2

-

+

1xE3 IDU

Tx

Rx

Tx

External EOW (OPTIONAL)

ODU CABLE

Q-LAN

V-LAN

C H B

C B L

O D U

'

V-BUS LCT

USER/Dext

USER/Dext '

µ TEL

Ä'

I

LCT

M N

C /

/ W

M J

4 WIRE + E&M ______________________ EXP1 EXP2 I

LINE STATUS _I I INS _II

T E S T

EOW ______

V.11 LINE1

PWR- 48V

© 2006 Siemens AG

C H A

PS

SRAL XD

2 Mb/s WST

ALMs

+

IMC 00031METD Issue 1, June 2006

Rx

s

34 Mb/s

V.11 LINE2

-

3-13

SRAL XD (plug-in IDU)

Siemens

Fig. 3.10 1+1 FD, PD system with 2 independent antennas (Terminal)

16xE1 / 32xE1 / ETH IDU Tx5

Tx1

Tx9

Rx5

Rx1

Tx13

Rx9

s

Rx13

I

USER/Dext

LCT

µ TEL

I

LINE STATUS _I I INS _II

Ä'

LCT

OR

EOW ______

V.11 LINE1

PWR- 48V

V-LAN

0

4 WIRE + E&M ______________________ EXP1 EXP2 I

USER/Dext

PS

SRAL XD Q-LAN

ALMs

V.11 LINE2

-

+

1xE3 IDU

External EOW (OPTIONAL) Tx

Tx

Rx

Rx ODU CABLE

s

34 Mb/s

Q-LAN

V-LAN

USER/Dext

USER/Dext '

µ TEL

Ä'

I

LCT

M N

C /

/ W

M J

C B L

O D U

'

4 WIRE + E&M ______________________ EXP1 EXP2 I

LINE STATUS _I I INS _II

T E S T

EOW ______

V.11 LINE1

PWR- 48V

3-14

C H B

V-BUS LCT

+

C H A

PS

SRAL XD

2 Mb/s WST

ALMs

V.11 LINE2

-

IMC 00031METD Issue 1, June 2006 © 2006 Siemens AG

SRAL XD (plug-in IDU)

Siemens

Fig. 3.11 1+1 PD system with 1 independent antenna (Terminal)

16xE1 / 32xE1 / ETH IDU

Tx5

Tx1

Tx9

Rx5

Rx1

Tx13

Rx9

s

Rx13

I

USER/Dext

LCT

µ TEL

I

LINE STATUS _I I INS _II

Ä'

LCT

OR

EOW ______

V.11 LINE1

PWR- 48V

V-LAN

0

4 WIRE + E&M ______________________ EXP1 EXP2 I

USER/Dext

PS

SRAL XD Q-LAN

ALMs

V.11 LINE2

-

+

1xE3 IDU

External EOW (OPTIONAL)

Tx

Tx

Rx

Rx ODU CABLE

s

34 Mb/s

Q-LAN

USER/Dext

Ä'

I

LCT

M N /

C / M

T

W

J

C B L

O D U

'

4 WIRE + E&M ______________________ EXP1 EXP2 I

LINE STATUS _I I INS _II

T E S

EOW ______

V.11 LINE1

µ TEL

© 2006 Siemens AG

C H B

V-BUS

USER/Dext '

PWR- 48V

IMC 00031METD Issue 1, June 2006

V-LAN

LCT

+

C H A

PS

SRAL XD

2 Mb/s WST

ALMs

V.11 LINE2

-

3-15

SRAL XD (plug-in IDU)

Siemens

Fig. 3.12 SRAL XD - 7/8 GHz: 1+1 H/S, FD system with 1 independent antenna (Terminal)

16xE1 / 32xE1 / ETH IDU

Tx1

Tx5

Rx1

Tx9

Rx5

Tx13

Rx9

s

Rx13

USER/Dext

I

USER/Dext

µ TEL

LCT

LCT

OR

EOW ______ 4 WIRE + E&M ______________________ EXP1 EXP2 I

I

LINE STATUS _I I INS _II

Ä'

V-LAN

0

V.11 LINE1

PWR- 48V

PS

SRAL XD Q-LAN

ALMs

V.11 LINE2

-

+

1xE3 IDU

Tx

Rx

Tx

Rx ODU CABLE

s

34 Mb/s

Q-LAN

V-LAN

USER/Dext

USER/Dext '

µ TEL

3-16

Ä'

I

LCT

M N /

C / M

T

W

J

C B L

O D U

'

4 WIRE + E&M ______________________ EXP1 EXP2 I

LINE STATUS _I I INS _II

T E S

EOW ______

V.11 LINE1

PWR- 48V

+

C H B

V-BUS LCT

External EOW (OPTIONAL)

C H A

PS

SRAL XD

2 Mb/s WST

ALMs

V.11 LINE2

-

IMC 00031METD Issue 1, June 2006 © 2006 Siemens AG

SRAL XD (plug-in IDU)

Siemens

Fig. 3.13 SRAL XD - 13-38 GHz: 1+1 H/S system with 1 integrated antenna (Terminal)

16xE1 / 32xE1 / ETH IDU

Tx1

Tx5

Rx1

Tx9

Rx5

Tx13

Rx9

s

Rx13

I

USER/Dext

LCT

µ TEL

I

LINE STATUS _I I INS _II

Ä'

LCT

OR

EOW ______

V.11 LINE1

PWR- 48V

V-LAN

0

4 WIRE + E&M ______________________ EXP1 EXP2 I

USER/Dext

PS

SRAL XD Q-LAN

ALMs

V.11 LINE2

-

+

1xE3 IDU External EOW (OPTIONAL) Tx

Rx

Tx

Rx ODU CABLE

s

34 Mb/s

Q-LAN

V-LAN

USER/Dext

USER/Dext '

µ TEL

© 2006 Siemens AG

Ä'

I

LCT

M N

C /

/ W

M J

C B L

O D U

'

4 WIRE + E&M ______________________ EXP1 EXP2 I

LINE STATUS _I I INS _II

T E S T

EOW ______

V.11 LINE1

PWR- 48V

IMC 00031METD Issue 1, June 2006

C H B

V-BUS LCT

+

C H A

PS

SRAL XD

2 Mb/s WST

ALMs

V.11 LINE2

-

3-17

SRAL XD (plug-in IDU)

Siemens

Fig. 3.14 SRAL XD - 13-38 GHz: 1+1 H/S system with 1 independent antenna (Terminal)

16xE1 / 32xE1 / ETH IDU

Tx5

Tx1

Tx9

Rx5

Rx1

Tx13

Rx9

s

Rx13

I

USER/Dext

µ TEL

EOW ______ I

LINE STATUS _I I INS _II

Ä'

LCT

OR

LCT

V.11 LINE1

PWR- 48V

V-LAN

0

4 WIRE + E&M ______________________ EXP1 EXP2 I

USER/Dext

PS

SRAL XD Q-LAN

ALMs

V.11 LINE2

-

+

1xE3 IDU External EOW (OPTIONAL) Tx

Rx

Tx

Rx

ODU CABLE

Q-LAN

V-LAN

H B

C

O

B L

D U

'

V-BUS LCT

USER/Dext

USER/Dext '

µ TEL

Ä'

I

LCT

M N /

C / M

T

W

J

4 WIRE + E&M ______________________ EXP1 EXP2 I

LINE STATUS _I I INS _II

T E S

EOW ______

V.11 LINE1

PWR- 48V

3-18

C

PS

SRAL XD

2 Mb/s WST

ALMs

+

C H A

s

34 Mb/s

V.11 LINE2

-

IMC 00031METD Issue 1, June 2006 © 2006 Siemens AG

SRAL XD (plug-in IDU)

Siemens

Fig. 3.15 1+0 supporting frame B

A

ODU Waveguide

Frame

1+0 supporting frame Code

Freq. Band (GHz)

Freq. Range (GHz)

W.G. Type

Port A Flange type

Port B Flange type

534-108/69

7

7.1 - 7.9

WR112 R84

UDR84

PDR84

534-108/69

8

7.7 - 8.5

WR112 R84

UDR84

PDR84

534-108/71

13

12.75-13.25

WR 75 R120

UBR120

PBR120

534-108/72

15

14.4 - 15.35

WR62 R140

UBR140

PBR140

534-108/73

18

17.7 - 19.7

WR42 R220

UBR220

PBR220

534-108/73

23

21.2 - 23.6

WR42 R220

UBR220

PBR220

534-108/73

26

24.5 - 26.5

WR42 R220

UBR220

PBR220

534-108/74

28

27.5 - 29.5

WR28 R320

UBR320

PBR320

534-108/74

38

37.5 - 39.5

WR28 R320

UBR320

PBR320

IMC 00031METD Issue 1, June 2006 © 2006 Siemens AG

3-19

SRAL XD (plug-in IDU)

Siemens

Fig. 3.16 1+1 supporting frame for frequency diversity C

ODU

A

B Circulator

ODU

Frame

1+1 supporting frame for frequency diversity

3-20

Code

Freq. Band (GHz)

Freq. Range (GHz)

Guide type

Port A Port B, C Insertion Flange Flange Loss type type (dB)

534-108/80

7

7.1 - 7.9

WR112 R84

UDR84

PDR84

534-108/81

8

7.7 - 8.5

WR112 R84

UDR84

PDR84

Isolation (dB)

< 0.3

> 20

< 0.2

> 26

< 0.3

> 20

< 0.2

> 26

IMC 00031METD Issue 1, June 2006 © 2006 Siemens AG

SRAL XD (plug-in IDU)

Siemens

Fig. 3.17 1+1 Supporting frame for Hot stand-by C

ODU

A

B Coupler

ODU

Frame

1+1 Supporting frame for Hot stand-by with integrated antenna Code 534-120/07 534-120/17 534-120/07 534-120/17 534-120/09 534-120/19 534-120/01 534-120/11 534-120/02 534-120/12 534-120/03 534-120/13 534-120/04 534-120/14 534-120/05 534-120/15 534-120/06 534-120/16

IMC 00031METD Issue 1, June 2006 © 2006 Siemens AG

Freq. Band (GHz) 7 7 8 8 13 13 15 15 18 18 23 23 26 26 28 28 38 38

Freq. Range (GHz) 7.1-7.9 7.1-7.9 7.7-8.5 7.7-8.5 12.75-13.25 12.75-13.25 14.4-15.35 14.4-15.35 17.7-19.7 17.7-19.7 21.2-23.6 21.2-23.6 24.5-26.5 24.5-26.5 27.5-29.5 27.5-29.5 37.5-39.5 37.5-39.5

Port A Coupler Guide type Flange type type unbal. WR112 R84 UDR84 bal. WR112 R84 UDR84 unbal. WR112 R84 UDR84 bal. WR112 R84 UDR84 unbal. WR75 R120 UBR120 bal. WR75 R120 UBR120 unbal. WR62 R140 UBR140 bal. WR62 R140 UBR140 unbal. WR42 R220 UBR220 bal. WR42 R220 UBR220 unbal. WR42 R220 UBR220 bal. WR42 R220 UBR220 unbal. WR28 R320 UBR320 bal. WR28 R320 UBR320 unbal. WR28 R320 UBR320 bal. WR28 R320 UBR320 unbal. WR28 R320 UBR320 bal. WR28 R320 UBR320

Port B,C Insertion Coupling Flange loss (dB) type (dB) PDR84 < 11
View more...

Comments

Copyright ©2017 KUPDF Inc.
SUPPORT KUPDF