Content
Scope of Work
Project Plan 110 Upgrade SIMO MIMO Jabo
Structure Organization
Delivery Plan
Technical Solution Implementation Implementat ion Flow and Checklist
Issue and Risk Project
HUAW EI TECHNOLOGIES CO., LTD.
Huawei Confidential
Page 2
Scope of Work Work - Wirele Wireless ss Region H3I
Jabodetabek
North Sulawesi
South West Sumatera
Scenario 1.1 1.2 1.3 1.2.a 1.1 1.2 1.3 1.2 1.3
Grand Total
Quantity Total Qty 7 17 110 84 2 46 22 83 15 11 58 47 251 251
Scenario
Jabo-1
Jabo-2
Grand To Total
1.1 1.2 1.2.a 1.3
2 10 2 49
5 7 0 35
7 17 2 84
Grand Total
63
47
110
RFC Cabinet RFC Cabinet + TP Cabinet RRU
Scenario 1.1 : Swap Existing MRFU to New RRU RRU ( RRU Install on pole near BTS C Cabinet abinet ( On Ground ) Scenario 1.2 : Add RFC Cabinet, Re-Use Re-Use MRFU from ex-Dismantle ex-Dismantle 1.1 ( 3 Sector) Scenario 1.2a : Add RFC Cabinet, Re-Use MRFU from ex-Dismantle 1.1 ( 4 Sector) Scenario 1.3 : Add RFC Cabinet, Re-Use Re-Use MRFU from Customer Customer WH ( 3 Sector )
HUAW EI TECHNOLOGIES CO., LTD.
Huawei Confidential
Page 3
: 65 sites : 38 sites : 7 sites
Sco Scope pe of Wor Work k - Powe Power r Region
North Sulawesi
Power Solution
Add PSU 1*30A 2U
2
Add PSU 1*50A 2U
4
New TP48200A + 100Ah
8
Add PSU 1*50A 2U
1
South Sumatera West New TP48200A + 100Ah
Jabotabek
Quantity Total
17
Swap Batteries to 2*100Ah
2
Add PSU 1*30A 2U
3
Add PSU 1*50A 2U
3
New TP48200A + 100Ah
38
Swap Batterei to 1*100Ah
1
14
20
45
Power Scenario
Add PSU 1*30A 2U
5
Add PSU 1*50A 2U
8
New TP48200A + 100Ah
63
Swap Batterei to 1*100Ah
1
Swap Batterei to 2*100Ah
2
Grand Total Grand Total
HUAW EI TECHNOLOGIES CO., LTD.
79
Quantity
79
Huawei Confidential
Page 4
79
Structure Team 251 SIMO MIMO Org Structure RPM Maya Della
Novianoka
RPC Intan Kumalasari
Acceptance Mgr Dedy Kurniawan
Project Manager Tommy Tri P.
Technical SolutionTeam Deka Irisandi
Engineer Aris Budiyanto
CR Managemennt
FSC Anis Farida
QC Regional Charles Pandapotan
Material Delivery
FSC Noer Fajar
FSC Hendro Prasetyo
Access and Alarm Management
Kharis Nugraha Collo. SAAF
eATP, BOQ
Quality
HUAW EI TECHNOLOGIES CO., LTD.
Huawei Confidential
Page 5
DC Support Miftahul Hasnah
Project Plan and Scenario Project Plan Milestone PO Release
June July Augustus September TOTAL W24 W25 W26 W27 W28 W29 W30 W31 W32 W33 W34 W35 W36 W37 W38 110 Done
PO Registration Material Inbound TSS Colo submit Colo Approval SAAF Submit
110 110 110 110 110 110
SAAF Approval MOS Site Integrated ( Beaming ) e-ATP CAC
110 110 110 110 110
Done 7 40 99
40 40 11
24 3 30 0
99 99
11 11
99 7 7
11 10 10 7
41
24 24 10
38
31 31 24
10 10 31
28 28 10
28 41
st
RRU RRU scen scenar ario io wi will ll im impl plem emen ente ted d as 1 nd batch RFC RFC ca cabi bine nett wi will ll be im impl plem emen ente ted d as 2 batch RFC+ RFC+TP TP cabi cabine nett wi will ll be impl implem emen ente ted d as 3rd batch Th This is RFC an and d TP cabi bin net migh ight be have so som me acce accele lerratio ation n in o case we found and confirmed by H3I that the site no TP needed. (existing TP still enough to cover current and upcoming upco ming DC pow power er requ requirem irement) ent)
HUAW EI TECHNOLOGIES CO., LTD.
Huawei Confidential
Page 6
69
Scenario 1.1 Swap Existing MRFU to RRU1800 2T2R (7 Sites) RRU 2T2R 3959
Ver er.. B AC type BTS3900A V
BTS3900A V Ver er.. B AC type
TCU
TCU
SLPU
SLPU
PMU
PSU
PSU
PSU
PMU
PSU
WBBP
WBBP
WBBP UBBPe4 WBBP
PSU
PDU
PDU c N A F
PSU
UMPT
WBBP c N A F
d U E P U
WBBP
WBBP UBBPe4 WBBP
UMPT
d U E P U
Install New Pole Near BTS Cabinet for New RRU Install 3 new RRU2T2R 3959 at New Pole U F R M 0 0 8 1 L G
U F R M 0 0 8 1 L G
U F R M 0 0 8 1 L G
U F R W 0 0 1 2 U
U F R W 0 0 1 2 U
U MRFU GL1800 F Dismantle 3 pcs existing MRFU R W Reconfigur Reconfigure e from SIMO to MIMO remotely at NOC 0 0 1 2 Update License additional RRC Connected User and Optional Feature Phase 2 U
BOTTOM OF RACK
HUAW EI TECHNOLOGIES CO., LTD.
U F R W 0 0 1 2 U
U F R W 0 0 1 2 U
BOTTOM OF RACK
Huawei Confidential
Page 7
U F R W 0 0 1 2 U
Scenario 1.2 Reusing MRFU ex-Dismantle Scenario 1.1 – 3 Sector (17 Sites) BTS3900A
BTS3900A Install new RFC Cabinet
TCU SLPU PMU
PSU
Move Existing 3 MRFU from existing RFC to new RFC Cabinet
TCU SLPU
PSU
PSU
PMU
PSU
PSU
Install 3 New MRFU to New RFC Cabinet ( Re-use from Ex-Dismantle Scenario 1.1)
PSU
Connect RF Cross Cable between MRFU PDU
PDU
WBBP c N
WBBP
WBBP
F A UBBPe4 WBBP
U F R M 0 0 8 1 L G
U F R M 0 0 8 1 L G
UMPT
Reconfigure from SIMO to MIMO remotely at NOC
WBBP d U E P U
WBBP
c N
WBBP
F A
UBBPe4 WBBP
UMPT
DCDU
DCDU
FMU
FMU
U F R M 0 0 8 1 L G
Update License additional RRC Connected User and Optional Feature Phase 2 d U E P U
DCDU FMU
U F R
U F R
U F R
U F R
U F R
U F R
U F R
U F R
U F R
U F R
U U F F R R
W 0 0 1 2 U
W 0 0 1 2 U
W 0 0 1 2 U
W 0 0 1 2 U
W 0 0 1 2 U
W 0 0 1 2 U
M 0 0 8 1 L G
M 0 0 8 1 L G
M 0 0 8 1 L G
M 0 0 8 1 L G
M 0 M 0 0 0 8 8 1 L 1 L G G
BOTTOM OF RACK
BOTTOM OF RACK
HUAW EI TECHNOLOGIES CO., LTD.
BOTTOM OF RACK
Huawei Confidential
Page 8
HUAW EI TECHNOLOGIES CO., LTD.
Huawei Confidential
Scenario 1.2.a Reusing MRFU ex-Dismantle Scenario 1.1 – 4 Sector (2 Site) BTS3900A
BTS3900A
BTS3900A
BTS3900A
Install new RFC Cabinet
Move Existing 1 MRFU from 1st RFC to 2 nd RFC
PMU
TCU
TCU
TCU
TCU
SLPU
SLPU
SLPU
SLPU
PSU
PSU
PSU
PMU
PDU
PSU
PSU
PSU
PMU
PSU
PSU
PSU
PMU
PSU
PDU
PDU
Cabinet Install 4 New MRFU to New RFC Cabinet ( Re-use
PSU
PSU
from Ex-Dismantle Scenario 1.1) Connect RF Cross Cable between MRFU
PDU
Reconfigure from SIMO to MIMO remotely at NOC
WBBP c N WBBP A F UBBPe4
WBBP
WBBP
U F R M 0 0 8 1 L G
U F R M 0 0 8 1 L G
UMPT
WBBP c N WBBP A F UBBPe4
d U E P U
WBBP
WBBP
UMPT
Update License additional RRC Connected User and
d U E P U
Optional Feature Phase 2
DCDU
DCDU
DCDU
DCDU
FMU
FMU
FMU
FMU
U F R M 0 0 8 1 L G
U F R W 0 0 1 2 U
U F R W 0 0 1 2 U
BOTTOM OF RACK
U F R W 0 0 1 2 U
U F R M 0 0 8 1 L G
U F R W 0 0 1 2 U
U F R W 0 0 1 2 U
BOTTOM OF RACK
U F R W 0 0 1 2 U
U F R M 0 0 8 1 L G
U F R M 0 0 8 1 L G
U F R W 0 0 1 2 U
U F R W 0 0 1 2 U
BOTTOM OF RACK
U F R W 0 0 1 2 U
U F R M 0 0 8 1 L G
U F R M 0 0 8 1 L G
U F R W 0 0 1 2 U
DCDU FMU U F R W 0 0 1 2 U
U F R W 0 0 1 2 U
BOTTOM OF RACK
Page 9
U F R M 0 0 8 1 L G
U F R M 0 0 8 1 L G
U F R M 0 0 8 1 L G
U F R M 0 0 8 1 L G
BOTTOM OF RACK
HUAW EI TECHNOLOGIES CO., LTD.
Huawei Confidential
Scenario 1.3 Reusing MRFU from H3I WH Scenario – 3 Sector (84 Sites) BTS3900A
BTS3900A Install new RFC Cabinet
TCU SLPU PMU
PSU
Move Existing 3 MRFU from existing RFC to new RFC Cabinet
TCU SLPU
PSU
PSU
PMU
PSU
PSU
Install 3 New MRFU to New RFC Cabinet ( Re-use from H3I WH)
PSU
Connect RF Cross Cable between MRFU PDU
PDU
WBBP c N
WBBP
WBBP
F A UBBPe4 WBBP
U F R M 0 0 8 1 L G
U F R M 0 0 8 1 L G
UMPT
Reconfigure from SIMO to MIMO remotely at NOC
WBBP d U E P U
WBBP
c N WBBP F A UBBPe4 WBBP
UMPT
DCDU
DCDU
FMU
FMU
U F R M 0 0 8 1 L G
Update License additional RRC Connected User and Optional Feature Phase 2 d U E P U
DCDU FMU
U F R
U F R
U F R
U F R
U F R
U F R
U F R
U F R
U F R
U F R
U U F F R R
W 0 0 1 2 U
W 0 0 1 2 U
W 0 0 1 2 U
W 0 0 1 2 U
W 0 0 1 2 U
W 0 0 1 2 U
M 0 0 8 1 L G
M 0 0 8 1 L G
M 0 0 8 1 L G
M 0 0 8 1 L G
M 0 M 0 0 0 8 8 1 1 L L G G
BOTTOM OF RACK
BOTTOM OF RACK
BOTTOM OF RACK
Page 10
HUAW EI TECHNOLOGIES CO., LTD.
Page 10
Huawei Confidential
RF Cross Cable Connection and Jumper Re-Connection
Main Jumper
CPRI Cable
HUAW EI TECHNOLOGIES CO., LTD.
Page 11
Huawei Confidential
Implementation Checklist Down time implementation Activity
PIC
Impact
Partner
2G&4G Down
Partner
2G&4G Down
Partner
2G&4G Down
Partner
2G&4G Down
Partner
2G&4G Down
Partner
2G&4G Down
Turn off Existing MRFU Move Existing MRFU to new MRFU Cabinet Connect RF Cross cable between MRFU Re-connect Jumper Inform to BSS for installation done. Running script command to configure from SIMO to MIMO
30 Min
30 Min
30 Min
HUAW EI TECHNOLOGIES CO., LTD.
Huawei Confidential
Page 12
Risk Project refer to SIMO MIMO 251
When SIMO only 1 (Main) Feeder line can detect VSWR alarm, There are possibility existing Diversity Feeder Line have VSWR alarm, but not detected. After MIMO implemented, both Feeder can detect VSWR alarm.
Limit Access Time dependency to CR Approval ( day time )
eATP Appro Approval val Proc Procedur edure e
Site Model ( Fix for the standard installa installation tion attend by HW RO, MS and H3I Team )
HUAW EI TECHNOLOGIES CO., LTD.
Huawei Confidential
Thank you www.huawei.com
Copyright©2011 Huawei Technologies Technologies Co., Ltd. All Rights Reserved. The information contained in this document is for reference purpose only, and is subject to change or withdrawal according to specific customer requirements and conditions.
Page 13
View more...
Comments