Solon LD / [Meaning ]

Troub rouble le Shooti Shooting ng

Duplicated door open/close command (ER_DOOR_COMMAND)

TCD 191

Part: TCD Code Ctrl No.: Solon_LD-TS-03-0 Page: 104/120

The open&close signals are inputted to DCD PCB at same time

Detection

 

○ Operation CPU   ○ Speed CPU

Application

Si231

[Countermeasures] 1. Check the voltage of DOC PCB as below When the command occurs

[Explanation ] If the door close &open command are inputted to DCD PCB, it sends an error signal to CP through car communication

DO-07(open) DO-06(Close)

±

0.7V 0.1V 0.7V ±0.1V

When the command cut ±

24V 10% 24V ±10%

2. Check the signals through ANN (2 row-13 & 14 column) 3. Even if the open and close command are cut the voltage is not 24V ±10%, check the followings 1)

Re Rem mov ove e the the insulation DO co con nne nect ctor orbetween from rom DOC-1 C140 PCB and proceed test 1&2 and earth. 2) If 1) is is n no ormal, rre eplace DO DOC-140 PCB. 4. Replace DCD-231 PCB

 

Solon LD / TCD 192 [Meaning ]

Troub rouble le Shooti Shooting ng

Do or or p os os it it iio o n t ro ro u ub b le le Door position detector error

Detection

 

○ Operation CPU   ○ Speed CPU

Part: TCD Code Ctrl No.: Solon_LD-TS-03-0 Page: 105/120

Application

Si231

[Countermeasures] ( SED1 SED1 Door app licati on )

[Explanation ] ( SED1 SED1 Door app applic lic ation ) In case of the trouble of door thermal, under voltage, over voltage & current, TCD192 occurs.

1. Check the JN2 connector of DCD-231 PCB JN2-1(red), JN2-2(white), JN2-3(Green), JN2-4(black) 2. Check the voltage of JN2 connector  1) JN2-1 ⇔JN2-4: 15V±10% 2) in case the voltage is not 15V±10%, remove the JN2 connector and check the voltage on DCD-231 PCB. 3) If the voltage of 2) is 15V±10%, the R.E is detective. 4) But if the voltage of 2) is not 15V±10%, the DCD-231 PCB detective. 3. Check the phase voltage voltage between of JN2 connector  1)Check the phase JN2-4 and JN2-2(A phase) as turning a motor with manual. When the motor stops, if the voltage is 15V ±10% or 1V less is detected any one time in 10times trial, the phase A is normal. 2) Check the phase B as Phase A. 3) The Phase A & B is normal, the DCD-231 PCB is detective. 2. Check if the OLS and CLS are working normally.

 

Solon LD / Door voltage trouble(ER_DOOR_VOLTAGE)

TCD 193 [Meaning ]

Troub rouble le Shooti Shooting ng

Door input voltage error

[Explanation ] Error detected and transmitted to operation CPU when the input voltage of DCD-231 PCB is over or low voltage. 1) Low voltage : under AC 77V (110V -30%) 2) High voltage : over AC 154V (110V +40%)

Detection

 

○ Operation CPU   ○ Speed CPU

Part: TCD Code Ctrl No.: Solon_LD-TS-03-0 Page: 106/120

Application

Si231

[Countermeasures]

1. Check the PJ1 connector of DCD-23X PCB. The voltage between PJ1-17 and PJ1-8 is  AC 110V±20%. (normal) 2. Above 1 is normal : DCD-23X PCB is troubled 3. Above 1 is abnormal, check below items: 1) Main power voltage is within AC323V~AC418V. (normal) 2) 1) is normal : Control transformer is troubled.

 

Solon LD / TCD 194 [Meaning ]

Troub rouble le Shooti Shooting ng

Door moto m otorr th thermal ermal ttrou rouble ble (ER_ (ER_DOO DOOR_M R_MOTO OTOR_T R_THER HERMAL) MAL) Door motor over_heat error

Detection

 

○ Operation CPU   ○ Speed CPU

Part: TCD Code Ctrl No.: Solon_LD-TS-03-0 Page: 107/120

Application

Si231

[Countermeasures] 1. Check if the door motor is real heat .

[Explanation ]

Error detected and transmitted to operation CPU when the motor coil temperature is over 130℃.

* Cautio Cautio n : Motor f rame temperature temperature is o ver 100 100  when the moto r were real heat. heat.

2. In case that the door motor is real heat 1) Remove any obstacles to door open/close on car or landing sill. 2) Refer to the countermeasure 1), 2) of TCD 191. 3. In case that the door motor is not real heat. Check if between PJ2-4 and PJ2-5 pins are shortage after powerPCB. off and disconnecting PJ2 connector from DCD-23X 1) Shortage: DCD-23X PCB is troubled 2) Open: Motor is troubled.

 

Solon LD / TCD 195 [Meaning ]

Troub rouble le Shooti Shooting ng

Door motor moto r over current tro ubl e( e(ER ER_D _DOO OOR_ R_OC OC)) Door motor over_current error

[Explanation ]

Error detected and transmitted to operation CPU when the over current flows in inverter part .

Detection

 

○ Operation CPU   ○ Speed CPU

Part: TCD Code Ctrl No.: Solon_LD-TS-03-0 Page: 108/120

Application

Si231

[Countermeasures] 1. Check the below items (Motor side) after disconnecting PJ2 connector from DCD-23X PCB. 1) Check the isolation of between PJ2-1,2,3 pin and Earth. 2) Check resistance value between PJ2-1 and PJ-2 pin. Value for 50W Door Motor: 17.6Ω±10% Value for 80W Door Motor: 10Ω±10% 3) Check the resistance as above PJ2-1,3 and PJ-2,3 pin. 4) In case that the test result were not good, motor is troubled 2. If the result is normal, check below Items after power off. 1) Check the isolation of between PJ2-1,2,3 pin and Earth. 2) Check the isolation at PJ2-1,2 , PJ2-1,3 and PJ-2,3 pin. 3. Check shortage between DCD-23X & door box frame. 4. Replace DCD-23X PCB.

 

Solon LD / TCD 199 [Meaning ]

Troub rouble le Shooti Shooting ng

ER_P ER _PCB_P CB_Prot rot ect_Fa ect_Failil (Korea do domesti mesti c onl y) The security approval for PCB is failed. When a DOC or DCL PCB is replaced, it detects error. Or SPEC data is damaged, it also detects an error

[Explanation ]

Whenever a DOC PCB or DCL PCB is replaced replaced in Korea, the security security system in CP request serviceman’s ID and approval number. If this requirement is not satisfied, the PCB protection program will not removed. So, its operation shall be locked.

Detection

 

○ Operation CPU   ○ Speed CPU

Part: TCD Code Ctrl No.: Solon_LD-TS-03-0 Page: 109/120

Application

Si231

[Countermeasures] 1. If this error is founded in your field, request new PCB.  And the wrong PCB that makes makes TCD199 must be back to manufacturer with claim letter.

 

Solon LD / TCD 200 [Meaning ]

Troub rouble le Shooti Shooting ng Detection

CNET LO LON N co commu mmunic nica atio tion n tr troub ouble le DPRAM communication between Main LON and i186 does not operate

[Explanation ] 1.It will detect an error if the 4th bit(DPRAM: 0x10) of input port of i186 system is ‘HIGH’ condition and and a condition that that the TOKEN is not pa passed ssed

 

○ Operation CPU   ○ Speed CPU

Part: TCD Code Ctrl No.: Solon_LD-TS-03-0 Page: 110/120

Application

Si231

[Countermeasures] 1. If the trouble doesn’t disappear after system reset on DOC-140, Check if ROM(OS ROM) of DOC-140 & ROM of main LON are mounted correctly. 2. If the trouble doesn’t disappear after performing 1 item above, Replace ROM(OS ROM) of DOC-140 & ROM of main LON.

through LON continuously continuously more than 6 cycle (180msec). 2. In case the main LON CPU of DOC-140 PCB is unable to work. (The 2nd bit(CNET_CPU_ERR:0x04) bit(CNET_CPU _ERR:0x04) of input port of i186 system is ‘HIGH’ ‘HIG H’ condition condition))

I186EC_Port3_Input & 0x20

*SYS_INPUT_PORT & 0x10

Coil[VALID_186_TOKEN]

Coil[VALID_186_TOKEN]

+1

err_count

0x9300

err_count > 5

*SYS_INPUT_PORT & 0x04

[Condition ] LON LED on DOC-140 will light off.

TCD 200

3. Replace DOC-140 even if nothing is improved after performing item 2 above.

 

Solon LD / TCD 202

Troub rouble le Shooti Shooting ng Detection

Car com commu muni nica cati tion on trou tr oubl ble e

[Meaning ]

Car LON communication trouble on main OPB( OPB ID = 1 )

[Explanation ] CND_OPB_Node_State & 0x01 TCD 202

* TCD 202 is detected on MAIN LON and write in DPRAM. variable of appropriate data is read and saved is CND_OPB_Node_State.

 

○ Operation CPU   ○ Speed CPU

LON LEDs of DOC-140 and DCL-243 DCL-243 are flickering with 1.2 1.2 sec. cycle

Application

Si231

[Countermeasures] 1. Check the ON/OFF state of LON LED in DOC-140 (0.06 sec. cycle when normal). 2. Check the ON/OFF state of DCL-243 LED (0.2 sec. cycle when normal). 3. Verify if the connector(SC) for LON communication is normally connected. 4. Verify if OPB ID is 1 (DIP 1 ‘ON’). 5. Verify if DCL-243 has a terminal resistor(DIP 8) set. 6. Measure the resistance between pins No. 1, 2 of SC connector. If it is is approximately approximately 10 OHM, normal. If there is no resistance, check for disconnection. disconnection. 7. Replace ROM(OS ROM) of DOC-120 & ROM Main LON. 8. Replace DCL-243. 9. Replace DOC-140.

[Condition ]

Part: TCD Code Ctrl No.: Solon_LD-TS-03-0 Page: 111/120

 

Solon LD / TCD 205

Troub rouble le Shooti Shooting ng Detection

DES co comm mmun unic ica ation tion ttro roub uble le

[Meaning ]

Application

Si231

1. Check the flickering state of LON LED in DES-102 PCB ( 1 sec. cycle when normal ). 2. Verify if the connector(P7) for LON communication is normally connected. 3. Measure the resistance between pins No. 3, 4 of P7 connector.

[Explanation ] CND_OPB_Node_State & 0x04 TCD 205

LON_OK LED of DES PCB is hold

○ Operation CPU   ○ Speed CPU

[Countermeasures]

DES PCB LON communication trouble ( OPB ID = 4 )

[Condition ]

 

Part: TCD Code Ctrl No.: Solon_LD-TS-03-0 Page: 112/120

If it is is approximately approximately 10 OHM, normal. If there is no resistance, check for disconnection. disconnection. 4. Replace ROM(Main LON ROM) of DOC-120 & DES-100 PCB ROM. 5. Replace DES-102 PCB 6. Replace DOC-140 PCB.

 

Solon LD / ER_REAR_OPB_COM

TCD 206 [Meaning ]

Troub rouble le Shooti Shooting ng Detection

 

○ Operation CPU   ○ Speed CPU

Part: TCD Code Ctrl No.: Solon_LD-TS-03-0 Page: 113/120

Application

Si231

Car LON communication trouble on main OPB( OPB ID = 5 )

[Explanation ]

* TCD 202 is detected on MAIN LON and write in DPRAM. variable of appropriate data is read and saved is CND_OPB_Node_State.

1. Check the ON/OFF state of LON LED in DOC-140 (0.06 sec. cycle when normal). 2. Check the ON/OFF state of DCL-243 LED (0.2 sec. cycle when normal). 3. Verify if the connector(SC) for LON communication is normally connected. 4. Verify if OPB ID is 5 (DIP 1,3 ‘ON’). 5. Verify if DCL-243 has a terminal resistor(DIP 8) set. 6. Measure the resistance between pins No. 1, 2 of SC connector. If it is is approximately approximately 10 OHM, normal. If there is no resistance, check for disconnection. disconnection. 7. Replace ROM(OS ROM) of DOC-140 & ROM Main LON. 8. Replace DCL-243. 9. Replace DOC-140. 10. Check the ROM version of DCL PCB.

[Condition ] LON LEDs of DOC-140 and DCL-243 DCL-243 are flickering with 1.2 1.2 sec. cycle

 

Solon LD / TCD 211 [Meaning ]

Part: TCD Code Ctrl No.: Solon_LD-TS-03-0 Page: 114/120

Troub rouble le Shooti Shooting ng

Oth the er ele eleva vato torr tro troub uble le Communication Communicat ion error with other car is detected in duplex operation.

[Explanation ] 1. In duplex, In case there is no transmission data for 1 sec. from other elevator, the trouble occurs. 2. When G/A transmission transmission from other other is failed 4 times in series, the trouble occurs occurs..

Detection

 

○ Operation CPU   ○ Speed CPU

Application

Si231

[Countermeasures] 1. In case of duplex, No.1 of the SPEC1(DIP S/W) must be on. In case of simplex, it must be off. 2. Check the condition of communication line between 2 elevators. The communication communication line must be a shield wire. 3. Check if terminal resistor(HJP-SH resistor(HJP-SH Jumper) is co connected. nnected. In case of figure below, don’t connect terminal resistor of No. 1 but No. 2. No. 1

No. 2

HJP SH

SH

SL

HJP SH SL

DHG-16X

DHG-16X

DHG-16X

SH

 

Solon LD / TCD 217 [Meaning ]

Troub rouble le Shooti Shooting ng Detection

Hall b but utto ton n ja jam md de ete tect ctio ion n When hall button is being pushed continuously, the trouble is detected.

 

○ Operation CPU   ○ Speed CPU

Part: TCD Code Ctrl No.: Solon_LD-TS-03-0 Page: 115/120

Application

[Countermeasures] 1. Check the floor where button jam is detected. The floor can be checked by ‘A21E’.

[Explanation ]

2. If abnormal, replace the button.

When hall button is being pushed for the time(Default :180 sec.) that is designated by SPEC, TCD 217 will occur. Button_Jam_Detect[0][UP_INDX]

TCD 217

Button_Jam_Detect[0][DN_INDX]

The floor button Jam detected  Address

Floor

0x9954

1st floor ~ 8th floor UP Button

0x9955

9th floor ~ 16th floor UP Button

0x9956

17th floor ~ 24th floor UP Button

0x9957

25th floor ~ 32nd floor UP Button

0x9958

1st floor ~ 8th floor DOWN Button

0x9959

9th floor ~ 16th floor DOWN Button

0x995A

17th floor ~ 24th floor DOWN Button

0x995B

25th floor ~ 32nd floor DOWN Button

Each floor is matched with each Bit.

Si231

 

Solon LD / TCD 223

Troub rouble le Shooti Shooting ng Detection

Hal l CPU t ro ro u ub b lle e

[Meaning ] 1 or more communication trouble on Hall Station B/D, detected.

 

○ Operation CPU   ○ Speed CPU

Part: TCD Code Ctrl No.: Solon_LD-TS-03-0 Page: 116/120

Application

Si231

[Countermeasures] 1. Check the floor of communication not activated by  ANN - A21E and the ttype ype of button to to check DHG-16X DHG-16X of the failed floor for failure.

[Explanation ] [Checking of hall button trouble] Enter as below on annunciator

HND_Fail_Node[[ 0 ] HND_Fail_Node TCD 223 0x8762

* HND_Fail_Node HND_Fail_N ode : 4Byte( 32bit )

K: A21E  ADDR:DAT K : 8762E 8762E If 8762=x02(0000 0010) DFG-16X of 2nd floor is failure. If 8762 =x30(0011 0000) DFG-16X of 5th, 6th floors are failure. To see floor 8th or higher higher is required to enter KEY-PAD KEY-PAD ‘0’ of annunciator.

 Address

Floor 

0x8762

1st floor ~ 8th floor

0x8763

9th floor ~ 16th floor 

0x8764

17th floor ~ 24th floor 

0x8765

25th floor ~ 32nd floor

Each floor is matched with each Bit. Ex) ADDR:0x8762 - DATA:0x04 means means 3rd floor is out of order.

2. Verify if controller DOJ PCB XHA MIC is connected, and see if voltage between HA plug pin 3-4 of DHG-16X at failed floor is DC24V. 3. Verify if the ID of DHG-16X at failed floor is set correctly. 4. Resistance between HA connector pin1-2 in DHG-16X at the failed floor must be 2 ±0.5Ω. If not so, the pulse transformer(PT1, position position in DHG-16X) in DHG-16X is a failure. 5. Check between pin 3-4 of HA connector in DHG-16X at the failed floor. if it is open circuit, replace DHG-16X.

 

Solon LD / TCD 224

Troub rouble le Shooti Shooting ng Detection

Hal l n no o d ttrr ou ou b bll e (A llll )

[Meaning ] Communicati Communication on error with all floor in hall line is detected

NCD_P_SVC_Fl[ 0 ]

check_floor 

○ Operation CPU   ○ Speed CPU

Application

Si231

[Countermeasures]

[Explanation ]

Normal_Floor[ Normal_Floo r[ 0 ]

 

Part: TCD Code Ctrl No.: Solon_LD-TS-03-0 Page: 117/120

check_floor 

TCD 224

H_Data_Receive_Wait_Counter H_Data_Receive_Wa it_Counter == 0

[Condition ] When TCD224 occurs, operation mode would be ACD26 and perform backup operation.

1. Check if the jumper(HJP-SH) of DOC-140 is set correctly. 2. Check if XHA MIC of DOJ-130 PCB is connected. 3. Check if SH connector of DOC-140 is connected. 4. Check if terminal resistor(120Ω) in diverging box at bottom floor  is connected. 5. Check if the volt of XHA MIC of DOJ-130 PCB is DC24V after removing XHA MIC . 1) 1th ~ 8th floor: XHA 3-4 is to be DC24V. 2) 9th ~ 16th floor: XHA 5-6 is to be DC24V. 3) 17th ~ 24th floor: XHA 7-8 is to be DC24V. 4) 25th ~ 32th floor: TB2 (Terminal Block) 5-6 is to be DC24V.

 

Solon LD / TCD 236

Part: TCD Code Ctrl No.: Solon_LD-TS-03-0 Page: 118/120

Troub rouble le Shooti Shooting ng

TCI L O OC CK ttrr ou ou b bll e

[Meaning ]  Abnormal E.M E.M switch ON is detected detected unde underr CAR TOP MAINT o operation. peration.

Detection

 

○ Operation CPU   ○ Speed CPU

Application

[Countermeasures] 1. ERO switch ON / OFF in E&I panel 2. Main power OFF / ON

[Explanation ] When TCD236 occurs, TOCI TOCI switch is switched to NORMAL NORMAL side under Car TOP Maintenance operation.

Si231

 

Solon LD / TCD 237

Troub rouble le Shooti Shooting ng Detection

CRT co comm mmun unic ica ation tion ttro roub uble le

[Meaning ] When communication error between CRT & CP occurs

 

○ Operation CPU   ○ Speed CPU

Application

Si231

[Countermeasures] 1. Check if CRT option is applied. (When SPEC has CRT option even if a project does not apply for CRT, the trouble will occur)

[Explanation ] In case that there is no receive data from CRT for 8 sec., TCD237 would be occurs.

CRT_Comm_Error_Counter == 0

Part: TCD Code Ctrl No.: Solon_LD-TS-03-0 Page: 119/120

TCD 237

Crt_Id ADDR:0x0002 Crt_Operation ADDR:0x0020 2. Check if the connection between between CRT & CP is correct. (SM connector) Communication cable should be twisted & shielded. 3. Check if HJP-SL jumper is connected.

 

Solon LD / TCD 238

DES PCB t ro ro u ub b lle e

[Meaning ] DES PCB error occurs

Troub rouble le Shooti Shooting ng Detection

 

○ Operation CPU   ○ Speed CPU

Part: TCD Code Ctrl No.: Solon_LD-TS-03-0 Page: 120/120

Application

[Countermeasures] Refer to explanation of DES-102 PCB on PCB part

[Explanation ] In case of below conditi condition, on, TCD238 will occur. occur. 1. DES parameter error  2. Speed error  3. Temperature error  4. LCD error  5. Over speed detected 6. Communication error  7. Battery fault 8. Direction error 