Description
Artificial Lift
Sliding Sleeves
Table of Contents Company Profile ...................................................................................................................................................................5 Sliding Sleeves at Evolution Oil Tools.............................................................................................................................6 Sliding Sleeve Infographic.................................................................................................................................................7 Sliding Sleeve Specifications.............................................................................................................................................7 Sliding Sleeve Technical Information................................................................................................................13 Locations ..............................................................................................................................................................................33
Company Profile
Knowledgeable
Evolution Oil Tools is a group of
personnel providing
in order to meet your completion
and developing quality
provide wholesale products to
products and timely solutions to the Oil & Gas Industry
people that were brought together and subsurface tool needs. We accommodate your completion / service requirements. A portion of our product offering includes our own proprietary designs, patents and patent agreements to ensure that you are getting the required technology from the source. We can also offer Design and Engineering support to the product solutions provided to you. Our group combined, offers you over 100 years of experience in the Oil & Gas Industry, with the majority of that experience being in the tool business. We can also offer servicing capabilities for our product lines.
Make Evolution your tool solutions provider for all of your completion and subsurface tool needs and take advantage of our experience.
© 2014 Evolution Oil Tools Inc. All rights reserved.
This document is uncontrolled when printed.
5
Sliding Sleeves at Evolution Oil Tools
In Flow Control applications, Sliding Sleeves are essential tools for allowing communication between the tubular and the annulus. This enables circulation and selective zone production in the oil or gas recovery operation. Sliding Sleeves are set into either open or closed positions using standard wireline methods and the Evolution EB Shifting Tool. The tool comes in a variety of configurations based on the application requirements. Generally, Evolution Sliding Sleeves are distinguished as being either using upward jarring or downward jarring to open the tool; by the types of O-rings and seals that are installed in the tool, and by the nipple profile used in the tool. Evolution Oil Tools offers a complete line of Sliding Sleeve products to meet your needs.
6
This document is uncontrolled when printed.
© 2014 Evolution Oil Tools Inc. All rights reserved.
Sliding Sleeves
© 2014 Evolution Oil Tools Inc. All rights reserved.
This document is uncontrolled when printed.
7
Sliding Sleeves
SLFU / SLFA Sliding Sleeve
SL
SLFD Sliding Sleeve
Evolution Oil
SL
Evolution Oil
F
Baker-style "F" Top No-Go Nipple
Tools. F
Tools.
Baker-style "F" Top No-Go Nipple Profile.
Profile. U/A
UP to open.
D
DOWN to open.
Standard Material (Flow Wet): 4140-4145 L-80. (Other materials available upon request.) Elastomer: Viton O-rings and Carbon/Teflon Vee Seals. Max Temperature Rating: 375 ° F. Shifting Profile/Tool: Otis-style B. *Standard Pressure Sliding Sleeve, Average 6,000 +/- PSI working pressure.
NEFU / NEFA Sliding Sleeve
NE F
NEFD Sliding Sleeve
Non-Elastomeric
NE
Baker-style "F" Top No-Go Nipple Profile.
F
Non-Elastomeric Baker-style "F" Top No-Go Nipple Profile.
U/A
UP to open.
D
DOWN to open.
Standard Material (Flow Wet): 4140-4145 L-80. (Other materials available upon request.) Seals: Non-Elastomeric O-rings and Carbon/Teflon Vee Seals. Max Temperature Rating: 400 ° F. Shifting Profile/Tool: Otis-style B. *Standard Pressure Sliding Sleeve, Average 6,000 +/- PSI working pressure.
8
This document is uncontrolled when printed.
© 2014 Evolution Oil Tools Inc. All rights reserved.
Sliding Sleeves
SLXA Sliding Sleeve
SLXO Sliding Sleeve
SL
Evolution Oil
X
Otis-style "X" Selective Nipple Profile.
SL
Tools.
Evolution Oil Tools.
X
Otis-style "X" Selective Nipple
O
DOWN to open.
Profile. A
UP to open.
Standard Material (Flow Wet): 4140-4145 L-80. (Other materials available upon request.) Elastomer: Viton O-rings and Carbon/Teflon Vee Seals. Max Temperature Rating: 375 ° F. Shifting Profile/Tool: Otis-style B. *Standard Pressure Sliding Sleeve, Average 6,000 +/- PSI working pressure.
NEXA Sliding Sleeve
NE X
NEXO Sliding Sleeve
Non-Elastomeric Otis-style "X" Selective Nipple Profile.
NE X
Non-Elastomeric Otis-style "X" Selective Nipple Profile.
A
UP to open.
O
DOWN to open.
Standard Material (Flow Wet): 4140-4145 L-80. (Other materials available upon request.) Seals: Non-Elastomeric O-rings and Carbon/Teflon Vee Seals. Max Temperature Rating: 400 ° F. Shifting Profile/Tool: Otis-style B. *Standard Pressure Sliding Sleeve, Average 6,000 +/- PSI working pressure.
© 2014 Evolution Oil Tools Inc. All rights reserved.
This document is uncontrolled when printed.
9
Sliding Sleeves
SLA Sliding Sleeve
SLO Sliding Sleeve
SL
Evolution Oil
SL
Evolution Oil
*O
DOWN to open.
Tools. *A
Tools.
UP to open.
*These Sliding Sleeves have no Nipple Profiles, they have an Minimum I.D. > tubing drift O.D. or equal to tubing I.D. Standard Material (Flow Wet): 4140-4145 L-80. (Other materials available upon request.) Elastomer: Viton o-rings and Carbon/Teflon Vee Seals. Max Temperature Rating: 375 ° F. Shifting Profile/Tool: Otis-style B. *Standard Pressure Sliding Sleeve, Average 6,000 +/- PSI working pressure.
NEA Sliding Sleeve
NE *A
NEO Sliding Sleeve
Non-Elastomeric UP to open.
NE
Non-Elastomeric
*O
DOWN to open.
*These Sliding Sleeves have no Nipple Profiles, they have an Minimum I.D. > tubing drift O.D. or equal to tubing I.D. Standard Material (Flow Wet): 4140-4145 L-80. (Other materials available upon request.) Seals: Non-Elastomeric O-rings and Carbon/Teflon Vee Seals. Max Temperature Rating: 400 ° F. Shifting Profile/Tool: Otis-style B. *Standard Pressure Sliding Sleeve, Average 6,000 +/- PSI working pressure.
10
This document is uncontrolled when printed.
© 2014 Evolution Oil Tools Inc. All rights reserved.
Sliding Sleeves
SLRA Sleeve
SLRO Sliding Sleeve
SL
Evolution Oil
R
Otis-style "R" Selective Nipple Profile.
SL
Tools.
Evolution Oil Tools.
R
Otis-style "R" Selective Nipple Profile.
A
UP to open.
O
DOWN to open.
Standard Material (Flow Wet): 4140-4145 L-80. (Other materials available upon request.) Elastomer: Viton O-rings and Carbon/Teflon Vee Seals. Max Temperature Rating: 375 ° F. Shifting Profile/Tool: Otis-style B. High Pressure Sliding Sleeve, up to 10,000 PSI working pressure.
NERA Sliding Sleeve
NE R
NERO Sliding Sleeve
Non-Elastomeric Otis-style "R" Selective Nipple Profile.
NE
Non-Elastomeric
R
Otis-style "R" Selective Nipple
O
DOWN to open.
Profile. A
UP to open.
Standard Material (Flow Wet): 4140-4145 L-80. (Other materials available upon request.) Seals: Non-Elastomeric O-rings and Carbon/Teflon Vee Seals. Max Temperature Rating: 400 ° F. Shifting Profile/Tool: Otis-style B. High Pressure Sliding Sleeve, up to 10,000 PSI working pressure.
© 2014 Evolution Oil Tools Inc. All rights reserved.
This document is uncontrolled when printed.
11
Sliding Sleeves
EL Sliding Sleeve
E
Evolution Oil Tools.
L
Baker-style "F" Top No-Go Nipple Profile.
Standard Material (Flow Wet): 4140-4145 L-80. (Other materials available upon request.) Elastomer: Viton O-rings and 90 Duro Nitrile or HSN bonded seals and replaceable seals. Max Temperature Rating: 250 ° F. Shifting Profile/Tool:
*Baker-style D-2. * Otis style B with POSITIVE non self-releasing keys. Shear to release.
*Standard Pressure Sliding Sleeve, Average 6,000 +/- PSI working pressure.
EZ Sliding Sleeve
E
EZD Sliding Sleeve
Evolution Oil
E
Evolution Oil
Tools. *Z
Tools.
UP to open.
*ZD
DOWN to open.
*These Sliding Sleeves have no Nipple Profiles, they have an Minimum I.D. > tubing drift O.D. or equal to tubing I.D. Standard Material (Flow Wet): 4140-4145 L-80. (Other materials available upon request.) Elastomer: Viton O-rings and 90 Duro Nitrile or HSN bonded seals and replaceable seals. Max Temperature Rating: 250 ° F. Shifting Profile/Tool: Otis style B with POSITIVE non self-releasing keys. Shear to release. *Standard Pressure Sliding Sleeve, Average 6,000 +/- PSI working pressure. Otis® is a registered trademark of Halliburton Energy Services Inc.
Baker® is a registered trademark of Baker Hughes Inc. *Different Sizes of Sliding Sleeves have different Working Pressure Ratings, contact Evolution to confirm.
12
This document is uncontrolled when printed.
© 2014 Evolution Oil Tools Inc. All rights reserved.
SLFU Sliding Sleeve
Applications
Description
Displacing kill or completion fluid
The Evolution Model SLFU Sliding Sleeve is a
Allowing multiple zones to produce up one
down hole device, normally screwed into the
tubing string Selective testing of individual zones
production tubing, that allows communication between the tubing and the casing.
Selective stimulation of individual zones Circulating to kill the well
The device uses Viton O-rings as well as replaceable
Gas lifting the well
upper and lower easy-to-replace Vee seals. The Vee
Landing a blanking plug in the profile in the
seals can be of various elastomer types. The
upper sub to shut in the well, test the tubing,
standard seal material is a carbon graphite/Teflon®
or test the sleeve itself
composition.
Circulating inhibitors or methanol The SLFU Sliding Sleeve has a Baker®-style ‘F’ Top No-Go Nipple profile and a sealing bore in the
Features & Benefits
upper sub which serves as a receptacle for other
Non-elastomeric O-rings
Flow Control devices such as blanking plugs and
Can be run in any location in the tubing
separation tools. The lower sub also contains a seal
string
bore.
More than one can be used in the tubing string
The SLFU Sliding Sleeve can be installed at any point in the tubing string. More than one can be installed without any loss of function. When multiple sliding sleeves are in place, they can be selectively opened and closed in the tubing string. The EB Shifting Tool is used to shift the SLFU Sliding Sleeve open and closed. The tool is designed to that normal wireline activities will not open or close the sleeve inadvertently. Upward jarring opens the Inner Sleeve and downward jarring closes the Inner Sleeve. It is available in tubing sizes from 1.900” up to 5 ½”, in 4140 L-80 material, as well as premium steels such as 9 Cr, 13 Cr and Incoloy 925. The standard thread is EUE, but various premium threads may be machined into this tool as required.
Baker® is a registered trademark of Baker Hughes Inc.
© 2014 Evolution Oil Tools Inc. All rights reserved.
This document is uncontrolled when printed.
13
SLFD Sliding Sleeve
Applications
Description
Displacing kill or completion fluid
The Evolution Model SLFD Sliding Sleeve is a
Allowing multiple zones to produce up one
down hole device, normally screwed into the
tubing string Selective testing of individual zones
production tubing, that allows communication between the tubing and the casing.
Selective stimulation of individual zones Circulating to kill the well
The device uses Viton O-rings as well as replaceable
Gas lifting the well
upper and lower easy-to-replace Vee seals. The Vee
Landing a blanking plug in the profile in the
seals can be of various elastomer types. The
upper sub to shut in the well, test the tubing,
standard seal material is a carbon graphite/Teflon®
or test the sleeve itself
composition.
Circulating inhibitors or methanol The SLFD Sliding Sleeve has a Baker®-style ‘F’ Top No-Go Nipple profile and a sealing bore in the
Features & Benefits
upper sub which serves as a receptacle for other
Box-by-Pin configuration
Flow Control devices such as blanking plugs and
H 2 S service ready
separation tools. The lower sub also contains a seal
Non-elastomeric O-rings
bore.
Can be run in any location in the tubing string More than one can be used in the tubing string
The SLFD Sliding Sleeve can be installed at any point in the tubing string. More than one can be installed without any loss of function. When multiple sliding sleeves are in place, they can be selectively opened and closed in the tubing string. The EB Shifting Tool is used to shift the SLFD Sliding Sleeve open and closed. The tool is designed to that normal wireline activities will not open or close the sleeve inadvertently. Downward jarring opens the Inner Sleeve and upward jarring closes the Inner Sleeve. It is available in tubing sizes from 1.900” up to 5 ½”, in 4140 L-80 material, as well as premium steels such as 9 Cr, 13 Cr and Incoloy 925. The standard thread is EUE, but various premium threads may be machined into this tool as required.
Baker® is a registered trademark of Baker Hughes Inc.
14
This document is uncontrolled when printed.
© 2014 Evolution Oil Tools Inc. All rights reserved.
NEFU Sliding Sleeve
Applications
Description
Displacing kill or completion fluid
The Evolution Model NEFU Sliding Sleeve is a
Allowing multiple zones to produce up one
down hole device, normally screwed into the
tubing string Selective testing of individual zones
production tubing, that allows communication between the tubing and the casing.
Selective stimulation of individual zones Circulating to kill the well
The device contains non-elastomeric (Teflon®
Gas lifting the well
encapsulated Viton) O-rings as well as replaceable
Landing a blanking plug in the profile in the
upper and lower easy-to-replace Vee seals. The Vee
upper sub to shut in the well, test the tubing,
seals can be of various elastomer types. The
or test the sleeve itself
standard seal material is a carbon graphite/Teflon®
Circulating inhibitors or methanol
composition. The NEFU Sliding Sleeve has an F Landing Nipple
Features & Benefits
profile and a sealing bore in the upper sub which
Non-elastomeric O-rings
serves as a receptacle for other Flow Control
Can be run in any location in the tubing
devices such as blanking plugs and separation
string
tools. The lower sub also contains a seal bore.
More than one can be used in the tubing string
The NEFU Sliding Sleeve can be installed at any point in the tubing string. More than one can be installed without any loss of function. When multiple sliding sleeves are in place, they can be selectively opened and closed in the tubing string. The EB Shifting Tool is used to shift the NEFU Sliding Sleeve open and closed. The tool is designed to that normal wireline activities will not open or close the sleeve inadvertently. Upward jarring opens the Inner Sleeve and downward jarring closes the Inner Sleeve. It is available in tubing sizes from 1.900” up to 5 ½”, in 4140 L-80 material, as well as premium steels such as 9 Cr, 13 Cr and Incoloy 925. The standard thread is EUE, but various premium threads may be machined into this tool as required.
© 2014 Evolution Oil Tools Inc. All rights reserved.
This document is uncontrolled when printed.
15
NEFD Sliding Sleeve
Applications
Description
Displacing kill or completion fluid
The Evolution Model NEFD Sliding Sleeve is a
Allowing multiple zones to produce up one
down hole device, normally screwed into the
tubing string Selective testing of individual zones
production tubing, that allows communication between the tubing and the casing.
Selective stimulation of individual zones Circulating to kill the well
The device contains non-elastomeric (Teflon®
Gas lifting the well
encapsulated Viton) O-rings as well as replaceable
Landing a blanking plug in the profile in the
upper and lower easy-to-replace Vee seals. The Vee
upper sub to shut in the well, test the tubing,
seals can be of various elastomer types. The
or test the sleeve itself
standard seal material is a carbon graphite/Teflon®
Circulating inhibitors or methanol
composition. The NEFD Sliding Sleeve has an F Landing Nipple
Features & Benefits
profile and a sealing bore in the upper sub which
Non-elastomeric O-rings
serves as a receptacle for other Flow Control
Can be run in any location in the tubing
devices such as blanking plugs and separation
string
tools. The lower sub also contains a seal bore.
More than one can be used in the tubing string
The NEFD Sliding Sleeve can be installed at any point in the tubing string. More than one can be installed without any loss of function. When multiple sliding sleeves are in place, they can be selectively opened and closed in the tubing string. The EB Shifting Tool is used to shift the NEFD Sliding Sleeve open and closed. The tool is designed to that normal wireline activities will not open or close the sleeve inadvertently. Downward jarring opens the Inner Sleeve and upward jarring closes the Inner Sleeve. It is available in tubing sizes from 1.900” up to 5 ½”, in 4140 L-80 material, as well as premium steels such as 9 Cr, 13 Cr and Incoloy 925. The standard thread is EUE, but various premium threads may be machined into this tool as required.
16
This document is uncontrolled when printed.
© 2014 Evolution Oil Tools Inc. All rights reserved.
SLXA Sliding Sleeve
Applications
Description
Displacing kill or completion fluid
The Evolution Model SLXA Sliding Sleeve is a
Allowing multiple zones to produce up one
down hole device, normally screwed into the
tubing string Selective testing of individual zones
production tubing, that allows communication between the tubing and the casing.
Selective stimulation of individual zones Circulating to kill the well
The device uses Viton O-rings as well as replaceable
Gas lifting the well
upper and lower easy-to-replace Vee seals. The Vee
Landing a blanking plug in the profile in the
seals can be of various elastomer types. The
upper sub to shut in the well, test the tubing,
standard seal material is a carbon graphite/Teflon®
or test the sleeve itself
composition.
Circulating inhibitors or methanol The SLXA Sliding Sleeve has an Otis®-style ‘X’ Selective Nipple profile and a sealing bore in the
Features & Benefits
upper sub which serves as a receptacle for other
Pin by pin thread configuration.
Flow Control devices such as blanking plugs and
All sliding sleeves are H 2 S service ready.
separation tools. The lower sub also contains a seal
O-ring and Vee seal sealing mechanism
bore.
Do not wrench on the outer housing. The SLXA Sliding Sleeve can be installed at any point in the tubing string. More than one can be installed without any loss of function. When multiple sliding sleeves are in place, they can be selectively opened and closed in the tubing string. The EB Shifting Tool is used to shift the SLXA Sliding Sleeve open and closed. The tool is designed to that normal wireline activities will not open or close the sleeve inadvertently. Upward jarring opens the Inner Sleeve and downward jarring closes the Inner Sleeve. It is available in tubing sizes from 1.900” up to 5 ½”, in 4140 L-80 material, as well as premium steels such as 9 Cr, 13 Cr and Incoloy 925. The standard thread is EUE, but various premium threads may be machined into this tool as required.
Otis® is a registered trademark of Halliburton Energy Services Inc.
© 2014 Evolution Oil Tools Inc. All rights reserved.
This document is uncontrolled when printed.
17
SLXO Sliding Sleeve
Applications
Description
Displacing kill or completion fluid
The Evolution Model SLXO Sliding Sleeve is a
Allowing multiple zones to produce up one
down hole device, normally screwed into the
tubing string Selective testing of individual zones
production tubing, that allows communication between the tubing and the casing.
Selective stimulation of individual zones Circulating to kill the well
The device contains non-elastomeric (Teflon®
Gas lifting the well
encapsulated Viton) O-rings as well as replaceable
Landing a blanking plug in the profile in the
upper and lower easy-to-replace Vee seals. The Vee
upper sub to shut in the well, test the tubing,
seals can be of various elastomer types. The
or test the sleeve itself
standard seal material is a carbon graphite/Teflon®
Circulating inhibitors or methanol
composition.
Features & Benefits
Selective Nipple profile and a sealing bore in the
Pin by pin thread configuration.
upper sub which serves as a receptacle for other
All sliding sleeves are H 2 S service ready.
Flow Control devices such as blanking plugs and
O-ring and Vee seal sealing mechanism
separation tools. The lower sub also contains a seal
Do not wrench on the outer housing.
bore.
The SLXO Sliding Sleeve has an Otis®-style ‘X’
The SLXO Sliding Sleeve can be installed at any point in the tubing string. More than one can be installed without any loss of function. When multiple sliding sleeves are in place, they can be selectively opened and closed in the tubing string. The EB Shifting Tool is used to shift the SLXO Sliding Sleeve open and closed. The tool is designed to that normal wireline activities will not open or close the sleeve inadvertently. Upward jarring opens the Inner Sleeve and downward jarring closes the Inner Sleeve. It is available in tubing sizes from 1.900” up to 5 ½”, in 4140 L-80 material, as well as premium steels such as 9 Cr, 13 Cr and Incoloy 925. The standard thread is EUE, but various premium threads may be machined into this tool as required.
Otis® is a registered trademark of Halliburton Energy Services Inc.
18
This document is uncontrolled when printed.
© 2014 Evolution Oil Tools Inc. All rights reserved.
NEXA Sliding Sleeve
Applications
Description
Displacing kill or completion fluid
The Evolution Model NEXA Sliding Sleeve is a
Allowing multiple zones to produce up one
down hole device, normally screwed into the
tubing string Selective testing of individual zones
production tubing, that allows communication between the tubing and the casing.
Selective stimulation of individual zones Circulating to kill the well
The device contains non-elastomeric (Teflon®
Gas lifting the well
encapsulated Viton) O-rings as well as replaceable
Landing a blanking plug in the profile in the
upper and lower easy-to-replace Vee seals. The Vee
upper sub to shut in the well, test the tubing,
seals can be of various elastomer types. The
or test the sleeve itself
standard seal material is a carbon graphite/Teflon®
Circulating inhibitors or methanol
composition. The NEXA Sliding Sleeve has an Otis®-style ‘X’
Features & Benefits
Selective Nipple profile and a sealing bore in the
Pin by pin thread configuration.
upper sub which serves as a receptacle for other
All sliding sleeves are H 2 S service ready.
Flow Control devices such as blanking plugs and
O-ring and Vee seal sealing mechanism
separation tools. The lower sub also contains a seal
Do not wrench on the outer housing.
bore. The NEXA Sliding Sleeve can be installed at any point in the tubing string. More than one can be installed without any loss of function. When multiple sliding sleeves are in place, they can be selectively opened and closed in the tubing string. The EB Shifting Tool is used to shift the NEXA Sliding Sleeve open and closed. The tool is designed to that normal wireline activities will not open or close the sleeve inadvertently. Upward jarring opens the Inner Sleeve and downward jarring closes the Inner Sleeve. It is available in tubing sizes from 1.900” up to 5 ½”, in 4140 L-80 material, as well as premium steels such as 9 Cr, 13 Cr and Incoloy 925. The standard thread is EUE, but various premium threads may be machined into this tool as required.
Otis® is a registered trademark of Halliburton Energy Services Inc.
© 2014 Evolution Oil Tools Inc. All rights reserved.
This document is uncontrolled when printed.
19
NEXO Sliding Sleeve
Applications
Description
Displacing kill or completion fluid
The Evolution Model NEXO Sliding Sleeve is a
Allowing multiple zones to produce up one
down hole device, normally screwed into the
tubing string Selective testing of individual zones
production tubing, that allows communication between the tubing and the casing.
Selective stimulation of individual zones Circulating to kill the well
The device contains non-elastomeric (Teflon®
Gas lifting the well
encapsulated Viton) O-rings as well as replaceable
Landing a blanking plug in the profile in the
upper and lower easy-to-replace Vee seals. The Vee
upper sub to shut in the well, test the tubing,
seals can be of various elastomer types. The
or test the sleeve itself
standard seal material is a carbon graphite/Teflon®
Circulating inhibitors or methanol
composition.
Features & Benefits
Selective Nipple profile and a sealing bore in the
Pin by pin thread configuration.
upper sub which serves as a receptacle for other
All sliding sleeves are H 2 S service ready.
Flow Control devices such as blanking plugs and
O-ring and Vee seal sealing mechanism
separation tools. The lower sub also contains a seal
Do not wrench on the outer housing.
bore.
The NEXO Sliding Sleeve has an Otis®-style ‘X’
The NEXO Sliding Sleeve can be installed at any point in the tubing string. More than one can be installed without any loss of function. When multiple sliding sleeves are in place, they can be selectively opened and closed in the tubing string. The EB Shifting Tool is used to shift the NEXO Sliding Sleeve open and closed. The tool is designed to that normal wireline activities will not open or close the sleeve inadvertently. Upward jarring opens the Inner Sleeve and downward jarring closes the Inner Sleeve. It is available in tubing sizes from 1.900” up to 5 ½”, in 4140 L-80 material, as well as premium steels such as 9 Cr, 13 Cr and Incoloy 925. The standard thread is EUE, but various premium threads may be machined into this tool as required. Otis® is a registered trademark of Halliburton Energy Services Inc.
20
This document is uncontrolled when printed.
© 2014 Evolution Oil Tools Inc. All rights reserved.
SLA Sliding Sleeve
Applications
Description
Displacing kill or completion fluid
The Evolution Model SLA Sliding Sleeve is a down
Allowing multiple zones to produce up one
hole device, normally screwed into the production
tubing string Selective testing of individual zones
tubing, that allows communication between the tubing and the casing.
Selective stimulation of individual zones Circulating to kill the well
The device has replaceable upper and lower seals
Gas lifting the well
which are easy and inexpensive to replace. They
Landing a blanking plug in the profile in the
can be of various elastomer types.
upper sub to shut in the well, test the tubing, or test the sleeve itself Circulating inhibitors or methanol
The SLA Sliding Sleeve has no profile in the upper sub nor seal bores in either the upper sub or lower sub. This allows greater ID clearance. However, it restricts the installation of various flow control
Features & Benefits
devices, and should be used with careful
Pin by pin thread configuration.
consideration.
All sliding sleeves are H 2 S service ready. O-ring and Vee seal sealing mechanism
The Evolution Model EB Shifting Tool is used to shift
Do not wrench on the outer housing.
the SLA Sliding Sleeve open and closed. The tool is designed so that normal wireline activities will not open or close the sleeve inadvertently. Upward jarring opens the Inner Sleeve and downward jarring closes the Inner Sleeve. It is available in tubing sizes from 1.900” up to 5 1/2”, in 4140 L-80 material, as well as premium steels such as 9Cr or 13 Cr. The standard thread is EUE, but various premium threads may be machined into this tool as required.
Otis® is a registered trademark of Halliburton Energy Services Inc.
© 2014 Evolution Oil Tools Inc. All rights reserved.
This document is uncontrolled when printed.
21
SLO Sliding Sleeve
Applications
Description
Displacing kill or completion fluid
The Evolution Model SLO Sliding Sleeve is a down
Allowing multiple zones to produce up one
hole device, normally screwed into the production
tubing string Selective testing of individual zones
tubing, that allows communication between the tubing and the casing.
Selective stimulation of individual zones Circulating to kill the well
The device has replaceable upper and lower seals
Gas lifting the well
which are easy and inexpensive to replace. They
Landing a blanking plug in the profile in the
can be of various elastomer types.
upper sub to shut in the well, test the tubing, or test the sleeve itself Circulating inhibitors or methanol
The SLO Sliding Sleeve has no profile in the upper sub nor seal bores in either the upper sub or lower sub. This allows greater ID clearance. However, it restricts the installation of various flow control
Features & Benefits
devices, and should be used with careful
Pin by pin thread configuration.
consideration.
All sliding sleeves are H 2 S service ready. O-ring and Vee seal sealing mechanism
The Evolution Model EB Shifting Tool is used to
Do not wrench on the outer housing.
shift the SLO Sliding Sleeve open and closed. The tool is designed so that normal wireline activities will not open or close the sleeve inadvertently. Downward jarring opens the Inner Sleeve and upward jarring closes the Inner Sleeve. It is available in tubing sizes from 1.900” up to 5 1/2”, in 4140 L-80 material, as well as premium steels such as 9Cr or 13 Cr. The standard thread is EUE, but various premium threads may be machined into this tool as required.
Otis® is a registered trademark of Halliburton Energy Services Inc.
22
This document is uncontrolled when printed.
© 2014 Evolution Oil Tools Inc. All rights reserved.
NEA Sliding Sleeve
Applications
Description
Displacing kill or completion fluid
The Evolution Model NEA Sliding Sleeve is a
Allowing multiple zones to produce up one
down hole device, normally screwed into the
tubing string Selective testing of individual zones
production tubing, that allows communication between the tubing and the casing.
Selective stimulation of individual zones Circulating to kill the well
The device contains non-elastomeric (Teflon®
Gas lifting the well
encapsulated Viton) O-rings as well as replaceable
Landing a blanking plug in the profile in the
upper and lower easy-to-replace Vee seals. The Vee
upper sub to shut in the well, test the tubing,
seals can be of various elastomer types. The
or test the sleeve itself
standard seal material is a carbon graphite/Teflon®
Circulating inhibitors or methanol
composition.
Features & Benefits
sub nor seal bores in either the upper sub or lower
Pin by pin thread configuration.
sub. This allows greater ID clearance. However, it
All sliding sleeves are H 2 S service ready.
restricts the installation of various flow control
O-ring and Vee seal sealing mechanism
devices, and should be used with careful
Do not wrench on the outer housing.
consideration.
The NEA Sliding Sleeve has no profile in the upper
High temperature seals The Evolution Model EB Shifting Tool is used to shift the NEA Sliding Sleeve open and closed. The tool is designed so that normal wireline activities will not open or close the sleeve inadvertently. Upward jarring opens the Inner Sleeve and downward jarring closes the Inner Sleeve. It is available in tubing sizes from 1.900” up to 5 1/2”, in 4140 L-80 material, as well as premium steels such as 9Cr or 13 Cr. The standard thread is EUE, but various premium threads may be machined into this tool as required.
Otis® is a registered trademark of Halliburton Energy Services Inc.
© 2014 Evolution Oil Tools Inc. All rights reserved.
This document is uncontrolled when printed.
23
NEO Sliding Sleeve
Applications
Description
Displacing kill or completion fluid
The Evolution Model NEO Sliding Sleeve is a
Allowing multiple zones to produce up one
down hole device, normally screwed into the
tubing string Selective testing of individual zones
production tubing, that allows communication between the tubing and the casing.
Selective stimulation of individual zones Circulating to kill the well
The device contains non-elastomeric (Teflon®
Gas lifting the well
encapsulated Viton) O-rings as well as replaceable
Landing a blanking plug in the profile in the
upper and lower easy-to-replace Vee seals. The Vee
upper sub to shut in the well, test the tubing,
seals can be of various elastomer types. The
or test the sleeve itself
standard seal material is a carbon graphite/Teflon®
Circulating inhibitors or methanol
composition. The NEO Sliding Sleeve has no profile in the upper
Features & Benefits
sub nor seal bores in either the upper sub or lower
Pin by pin thread configuration.
sub. This allows greater ID clearance. However, it
All sliding sleeves are H 2 S service ready.
restricts the installation of various flow control
O-ring and Vee seal sealing mechanism
devices, and should be used with careful
Do not wrench on the outer housing.
consideration.
High temperature seals. The Evolution Model EB Shifting Tool is used to shift the NEO Sliding Sleeve open and closed. The tool is designed so that normal wireline activities will not open or close the sleeve inadvertently. Downward jarring opens the Inner Sleeve and upward jarring closes the Inner Sleeve. It is available in tubing sizes from 1.900” up to 5 1/2”, in 4140 L-80 material, as well as premium steels such as 9Cr or 13 Cr. The standard thread is EUE, but various premium threads may be machined into this tool as required.
Otis® is a registered trademark of Halliburton Energy Services Inc.
24
This document is uncontrolled when printed.
© 2014 Evolution Oil Tools Inc. All rights reserved.
NEA Sliding Sleeve
Description The Evolution Model SLRA Sliding Sleeve is a high
Applications
pressure down hole device, normally screwed into
Displacing kill or completion fluid
the production tubing, that allows communication
Allowing multiple zones to produce up one
between the tubing and the casing.
tubing string Selective testing of individual zones
The device uses Viton O-rings as well as replaceable
Selective stimulation of individual zones
upper and lower easy-to-replace Vee seals. The Vee
Circulating to kill the well
seals can be of various elastomer types. The
Gas lifting the well
standard seal material is a carbon graphite/Teflon®
Landing a blanking plug in the profile in the
composition.
upper sub to shut in the well, test the tubing, or test the sleeve itself Circulating inhibitors or methanol
The SLRA Sliding Sleeve has an Otis®-style ‘R’ Selective Nipple profile and a sealing bore in the upper sub which serves as a receptacle for other Flow Control devices such as blanking plugs and
Features & Benefits Pin by pin thread configuration. All sliding sleeves are H 2 S service ready. O-ring and Vee seal sealing mechanism Do not wrench on the outer housing. High pressure applications
separation tools. The lower sub also contains a seal bore. The SLRA Sliding Sleeve can be installed at any point in the tubing string. More than one can be installed without any loss of function. When multiple sliding sleeves are in place, they can be selectively opened and closed in the tubing string. The EB Shifting Tool is used to shift the SLRA Sliding Sleeve open and closed. The tool is designed to that normal wireline activities will not open or close the sleeve inadvertently. Upward jarring opens the Inner Sleeve and downward jarring closes the Inner Sleeve. It is available in tubing sizes from 1.900” up to 5 ½”, in 4140 L-80 material, as well as premium steels such as 9 Cr, 13 Cr and Incoloy 925. The standard thread is EUE, but various premium threads may be machined into this tool as required.
Otis® is a registered trademark of Halliburton Energy Services Inc.
© 2014 Evolution Oil Tools Inc. All rights reserved.
This document is uncontrolled when printed.
25
SLRA Sliding Sleeve
Applications
Description
Displacing kill or completion fluid
The Evolution Model SLRA Sliding Sleeve is a high
Allowing multiple zones to produce up one
pressure down hole device, normally screwed into
tubing string Selective testing of individual zones
the production tubing, that allows communication between the tubing and the casing.
Selective stimulation of individual zones Circulating to kill the well
The device uses Viton O-rings as well as replaceable
Gas lifting the well
upper and lower easy-to-replace Vee seals. The Vee
Landing a blanking plug in the profile in the
seals can be of various elastomer types. The
upper sub to shut in the well, test the tubing,
standard seal material is a carbon graphite/Teflon®
or test the sleeve itself
composition.
Circulating inhibitors or methanol The SLRA Sliding Sleeve has an Otis®-style ‘R’ Selective Nipple profile and a sealing bore in the
Features & Benefits
upper sub which serves as a receptacle for other
Pin by pin thread configuration.
Flow Control devices such as blanking plugs and
All sliding sleeves are H 2 S service ready.
separation tools. The lower sub also contains a seal
O-ring and Vee seal sealing mechanism
bore.
Do not wrench on the outer housing. High pressure applications
The SLRA Sliding Sleeve can be installed at any point in the tubing string. More than one can be installed without any loss of function. When multiple sliding sleeves are in place, they can be selectively opened and closed in the tubing string. The EB Shifting Tool is used to shift the SLRA Sliding Sleeve open and closed. The tool is designed to that normal wireline activities will not open or close the sleeve inadvertently. Upward jarring opens the Inner Sleeve and downward jarring closes the Inner Sleeve. It is available in tubing sizes from 1.900” up to 5 ½”, in 4140 L-80 material, as well as premium steels such as 9 Cr, 13 Cr and Incoloy 925. The standard thread is EUE, but various premium threads may be machined into this tool as required.
Otis® is a registered trademark of Halliburton Energy Services Inc.
26
This document is uncontrolled when printed.
© 2014 Evolution Oil Tools Inc. All rights reserved.
SLRO Sliding Sleeve
Applications
Description
Displacing kill or completion fluid
The Evolution Model SLRO Sliding Sleeve is a high
Allowing multiple zones to produce up one
pressure down hole device, normally screwed into
tubing string Selective testing of individual zones
the production tubing, that allows communication between the tubing and the casing.
Selective stimulation of individual zones Circulating to kill the well
The device uses elastomeric O-rings as well as
Gas lifting the well
replaceable upper and lower easy-to-replace Vee
Landing a blanking plug in the profile in the
seals. The Vee seals can be of various elastomer
upper sub to shut in the well, test the tubing,
types. The standard seal material is a carbon
or test the sleeve itself
graphite/Teflon® composition.
Circulating inhibitors or methanol The SLRO Sliding Sleeve has an Otis®-style ‘R’ Selective Nipple profile and a sealing bore in the
Features & Benefits
upper sub which serves as a receptacle for other
Pin by pin thread configuration.
Flow Control devices such as blanking plugs and
All sliding sleeves are H 2 S service ready.
separation tools. The lower sub also contains a seal
O-ring and Vee seal sealing mechanism
bore.
Do not wrench on the outer housing. High pressure applications.
The SLRO Sliding Sleeve can be installed at any point in the tubing string. More than one can be installed without any loss of function. When multiple sliding sleeves are in place, they can be selectively opened and closed in the tubing string. The EB Shifting Tool is used to shift the SLRO Sliding Sleeve open and closed. The tool is designed to that normal wireline activities will not open or close the sleeve inadvertently. Downward jarring opens the Inner Sleeve and upward jarring closes the Inner Sleeve. It is available in tubing sizes from 1.900” up to 5 ½”, in 4140 L-80 material, as well as premium steels such as 9 Cr, 13 Cr and Incoloy 925. The standard thread is EUE, but various premium threads may be machined into this tool as required.
Otis® is a registered trademark of Halliburton Energy Services Inc.
© 2014 Evolution Oil Tools Inc. All rights reserved.
This document is uncontrolled when printed.
27
NERA Sliding Sleeve
Applications
Description
Displacing kill or completion fluid
The Evolution Model NERA Sliding Sleeve is a
Allowing multiple zones to produce up one
high pressure down hole device, normally screwed
tubing string
into the production tubing, that allows
Selective testing of individual zones
communication between the tubing and the
Selective stimulation of individual zones
casing.
Circulating to kill the well Gas lifting the well
The device contains non-elastomeric (Teflon®
Landing a blanking plug in the profile in the
encapsulated Viton) O-rings as well as replaceable
upper sub to shut in the well, test the tubing,
upper and lower easy-to-replace Vee seals. The Vee
or test the sleeve itself
seals can be of various elastomer types. The
Circulating inhibitors or methanol
standard seal material is a carbon graphite/Teflon® composition.
Features & Benefits
The NERA Sliding Sleeve has an Otis®-style ‘R’
Pin by pin thread configuration.
Selective Nipple profile and a sealing bore in the
All sliding sleeves are H 2 S service ready.
upper sub which serves as a receptacle for other
O-ring and Vee seal sealing mechanism
Flow Control devices such as blanking plugs and
Do not wrench on the outer housing.
separation tools. The lower sub also contains a seal
High pressure applications up to 10,000 PSI
bore. The NERA Sliding Sleeve can be installed at any point in the tubing string. More than one can be installed without any loss of function. When multiple sliding sleeves are in place, they can be selectively opened and closed in the tubing string. The EB Shifting Tool is used to shift the NERA Sliding Sleeve open and closed. The tool is designed to that normal wireline activities will not open or close the sleeve inadvertently. Upward jarring opens the Inner Sleeve and downward jarring closes the Inner Sleeve. It is available in tubing sizes from 1.900” up to 5 ½”, in 4140 L-80 material, as well as premium steels such as 9 Cr, 13 Cr and Incoloy 925. The standard thread is EUE, but various premium threads may be machined into this tool as required.
Otis® is a registered trademark of Halliburton Energy Services Inc.
28
This document is uncontrolled when printed.
© 2014 Evolution Oil Tools Inc. All rights reserved.
NERO Sliding Sleeve
Applications
Description
Displacing kill or completion fluid
The Evolution Model NERO Sliding Sleeve is a
Allowing multiple zones to produce up one
high pressure down hole device, normally screwed
tubing string
into the production tubing, that allows
Selective testing of individual zones
communication between the tubing and the
Selective stimulation of individual zones
casing.
Circulating to kill the well Gas lifting the well
The device contains non-elastomeric (Teflon®
Landing a blanking plug in the profile in the
encapsulated Viton) O-rings as well as replaceable
upper sub to shut in the well, test the tubing,
upper and lower easy-to-replace Vee seals. The Vee
or test the sleeve itself
seals can be of various elastomer types. The
Circulating inhibitors or methanol
standard seal material is a carbon graphite/Teflon® composition.
Features & Benefits
The NERO Sliding Sleeve has an Otis®-style ‘R’
Pin by pin thread configuration.
Selective Nipple profile and a sealing bore in the
All sliding sleeves are H 2 S service ready.
upper sub which serves as a receptacle for other
O-ring and Vee seal sealing mechanism
Flow Control devices such as blanking plugs and
Do not wrench on the outer housing.
separation tools. The lower sub also contains a seal
High pressure applications up to 10,000 PSI
bore. The NERO Sliding Sleeve can be installed at any point in the tubing string. More than one can be installed without any loss of function. When multiple sliding sleeves are in place, they can be selectively opened and closed in the tubing string. The EB Shifting Tool is used to shift the NERO Sliding Sleeve open and closed. The tool is designed to that normal wireline activities will not open or close the sleeve inadvertently. Downward jarring opens the Inner Sleeve and upward jarring closes the Inner Sleeve. It is available in tubing sizes from 1.900” up to 5 ½”, in 4140 L-80 material, as well as premium steels such as 9 Cr, 13 Cr and Incoloy 925. The standard thread is EUE, but various premium threads may be machined into this tool as required.
Otis® is a registered trademark of Halliburton Energy Services Inc.
© 2014 Evolution Oil Tools Inc. All rights reserved.
This document is uncontrolled when printed.
29
EL Sliding Sleeve
Applications
Description
Displacing kill or completion fluid
The Evolution Model EL Sliding Sleeve is a down
Allowing multiple zones to produce up one
hole device, normally screwed into the production
tubing string Selective testing of individual zones
tubing, that allows communication between the tubing and the casing.
Selective stimulation of individual zones Circulating to kill the well
The device uses elastomeric O-rings as well as
Gas lifting the well
replaceable upper and lower easy-to-replace Vee
Landing a blanking plug in the profile in the
seals. The Vee seals can be of various elastomer
upper sub to shut in the well, test the tubing,
types. The standard seal material is a carbon
or test the sleeve itself
graphite/Teflon® composition.
Circulating inhibitors or methanol The EL Sliding Sleeve has an Baker®-style ‘F’ Selective Nipple profile and a sealing bore in the
Features & Benefits
upper sub which serves as a receptacle for other
Pin by pin thread configuration.
Flow Control devices such as blanking plugs and
All sliding sleeves are H 2 S service ready.
separation tools. The lower sub also contains a seal
O-ring and Vee seal sealing mechanism
bore.
Do not wrench on the outer housing. The EL Sliding Sleeve can be installed at any point in the tubing string. More than one can be installed without any loss of function. When multiple sliding sleeves are in place, they can be selectively opened and closed in the tubing string. The ED-2 Shifting Tool is used to shift the EL Sliding Sleeve open and closed. The tool is designed to that normal wireline activities will not open or close the sleeve inadvertently. Downward jarring opens the Inner Sleeve and upward jarring closes the Inner Sleeve. It is available in tubing sizes from 1.900” up to 5 ½”, in 4140 L-80 material, as well as premium steels such as 9 Cr, 13 Cr and Incoloy 925. The standard thread is EUE, but various premium threads may be machined into this tool as required.
Baker® is a registered trademark of Baker Hughes Inc.
30
This document is uncontrolled when printed.
© 2014 Evolution Oil Tools Inc. All rights reserved.
EZ Sliding Sleeve
Applications
Description
Displacing kill or completion fluid
The Evolution Model EZ Sliding Sleeve is a down
Allowing multiple zones to produce up one
hole device, normally screwed into the production
tubing string Selective testing of individual zones
tubing, that allows communication between the tubing and the casing.
Selective stimulation of individual zones Circulating to kill the well
The device uses elastomeric O-rings as well as
Gas lifting the well
replaceable upper and lower easy-to-replace Vee
Landing a blanking plug in the profile in the
seals. The Vee seals can be of various Elastomer
upper sub to shut in the well, test the tubing,
types. The standard seal material is a carbon
or test the sleeve itself
graphite/Teflon® composition.
Circulating inhibitors or methanol The EZ Sliding Sleeve does not have a landing nipple profile built in to the upper sub. This means
Features & Benefits
the sliding sleeve can be used in cases where
Pin by pin thread configuration.
economy is a primary concern for the operator. It
All sliding sleeves are H 2 S service ready.
still has all the operational features and reliability of
O-ring and Vee seal sealing mechanism
the premium sliding sleeves in the product line.
Do not wrench on the outer housing. No profile, economical design.
The EZ Sliding Sleeve can be installed at any point in the tubing string. More than one can be installed without any loss of function. When multiple sliding sleeves are in place, they can be selectively opened and closed in the tubing string. The Evolution EB Shifting Tool is used to shift the EZ Sliding Sleeve open and closed. The tool is designed to that normal wirline activities will not open or close the sleeve inadvertently. Upward jarring opens the Inner Sleeve and downward jarring closes the Inner Sleeve. The standard thread is EUE, but various premium threads may be machined into this tool as required.
© 2014 Evolution Oil Tools Inc. All rights reserved.
This document is uncontrolled when printed.
31
EZD Sliding Sleeve
Applications
Description
Displacing kill or completion fluid
The Evolution Model EZD Sliding Sleeve is a
Allowing multiple zones to produce up one
down hole device, normally screwed into the
tubing string Selective testing of individual zones
production tubing, that allows communication between the tubing and the casing.
Selective stimulation of individual zones Circulating to kill the well
The device uses elastomeric O-rings as well as
Gas lifting the well
replaceable upper and lower easy-to-replace Vee
Landing a blanking plug in the profile in the
seals. The Vee seals can be of various Elastomer
upper sub to shut in the well, test the tubing,
types. The standard seal material is a carbon
or test the sleeve itself
graphite/Teflon® composition.
Circulating inhibitors or methanol The EZD Sliding Sleeve does not have a landing nipple profile built in to the upper sub. This means
Features & Benefits
the sliding sleeve can be used in cases where
Pin by pin thread configuration.
economy is a primary concern for the operator. It
All sliding sleeves are H 2 S service ready.
still has all the operational features and reliability of
O-ring and Vee seal sealing mechanism
the premium sliding sleeves in the product line.
Do not wrench on the outer housing. No profile, economical design.
The EZD Sliding Sleeve can be installed at any point in the tubing string. More than one can be installed without any loss of function. When multiple sliding sleeves are in place, they can be selectively opened and closed in the tubing string. The Evolution EB Shifting Tool is used to shift the EZD Sliding Sleeve open and closed. The tool is designed to that normal wirline activities will not open or close the sleeve inadvertently. Downward jarring opens the Inner Sleeve and upward jarring closes the Inner Sleeve. The standard thread is EUE, but various premium threads may be machined into this tool as required.
32
This document is uncontrolled when printed.
© 2014 Evolution Oil Tools Inc. All rights reserved.
Locations
CANADA #3, 1820 – 30th Ave NE Calgary, Alberta T2E 7M5 Toll Free: 1-800-265-TOOL (8665) Main: 403-243-1442 Fax: 403-258-2614 6415A - 63 St. Close Lloydminster, Alberta T9V 3B5 Tel: 780-522-8294 Fax: 780-875-6337 4512 – 81 Ave Edmonton, Alberta Tel: 587-758-9091 Cell: 780-919-1722 Cell: 780-893-1019
UNITED STATES OF AMERICA P.O. Box 5363 2908 Coffey Street Victoria, Texas 77903 Main: 361-575-7900 Fax: 361-575-8081 2400 Kermit Hwy Odessa, Texas 79764 Cell: 432-638-7902
© 2014 Evolution Oil Tools Inc. All rights reserved.
This document is uncontrolled when printed.
33
www.eotools.com
34
This document is uncontrolled when printed.
© 2014 Evolution Oil Tools Inc. All rights reserved.
View more...
Comments