PCB PARAMETRIZATION

Instr ns truc ucti tion ons s for fo r SERVICE UPDATES: 20/08/ 20/08/201 2012 2 2°edi 2°editi tion on

PCB sof tw are versio vers ion n V3.5.0 V3.5.0-89 -89 or hig her

CONTENTS

1

CONTROL PANEL MENU .................................................................................................................................... 3 1.1

ENGINEER MENU .......................................................... ........................................................... ....................... 3

2

PARAMETER LIST ................................................................................................................................................ 4

3

ERROR LIST ......................................................................................................................................................... 28

4

GAS ADAPTIVE SYSTEM .................................................. ........................................................... ..................... 33

5

FAULT FINDING ......................................................... ........................................................... ............................... 34

6

BURNER PHASE (FAULT HISTORY) ............................................................................................................. . 54

1

CONTROL CONTROL PANEL MENU

The following procedure is used to access the four boiler pro- gramming menus: • from the main menu C; • A e C for approx. 6 seconds; • B to see menus 1 - 2 - 3 - 4; • B to confirm the selected menu; • C to go back one menu at a time to the main menu.

The four menus are: 1 ENDUSER 2 COMMISSIONING 3 ENGINEER 4 OEM

1.1

(visible pressing the button C) (visible with a buttons combination) (visible only with PASSWORD 10101) 10101) (visible only with PASSWORD)

ENGINEER ENGINEER menu men u

 Access Engineer  menu  menu as described in section 1. This level includes all parameters present on Enduser and Commissioning menus. The details of this menu are given in next section. Some menus are avaible only if the system is correctly configured (e.g. solar menu). The parameters with grey underlight are different default values depending on boiler model.

2

PARAMETER LIST Parameter

Level 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Parameter

INFORMATION Room temperature Room temperature min Room temperature max Boiler temperature Outside temp Outside temp min Outside temp max Instant HW heater temp State central heating CH1 State central heating CH2 State central heating CH3 State hot water State boiler State SithermPro Telephone customer service

Displayed if the heating circuit is activated Displayed if the heating circuit is activated

Only with LMS15 pcb

Level

1 2 3 5 6

1 1 1 3 3

Parameter

SET TIME AND DA TE

Def au l t

OPERATOR SECTION

Def au l t

Hours / minutes Day / month Year Start of summertime End of summertime

Level

20

1

Change Language

24

2

Lighting

26

3

Operation lock

27

1

Programming lock

29

2

Units

40

2

Used as

42

2

 Assignment device 1

43

2

 Action operation

54 70

2 2

Readjustment room sensor Software version

Parameter

Off Temporarily Permanently On Off On Off 1 °C , bar 2 °F , PSI Operator unit 1 Room unit 1 Room unit 2 Room unit 3 Temps / mode CH1 Central heating 1 and 2 Central Heating 1 and 3  All central heatings 0 Locally 1 Centrally -3°C…+3°C

Block of the control panel buttons A e B The parameters can be displayed but not changed

The control panel is installed in the boiler The control panel is configured as room unit of heating circuit 1 The control panel is configured as room unit of heating circuit 2 The control panel is configured as room unit of heating circuit 3  As room unit 1, the action of the respective control panel can be assigned to heating circuit 1 or to 2 heating circuits. The room unit controls only the respective heating circuit. Only room unit 1 can be Centrally. It also controls dhw mode and standby.

Level

WIRELESS

120 121 130

2 2 2

Binding Test mode Room unit 1

 Activation of wireless link with basic unit Test mode is used for checking the wireless communication Check of link

131 132 133 134 135 140

2 2 2 2 2 2

Room unit 2 Room unit 3 Outside sensor Repeater Operator unit Delete all devices

Check of link Check of link Check of link Check of link Check of link

Parameter

Level

TIME CENTRA L HEATING 1 – 2 – 3

1 500 514 501 502 503 504 505 506

2 520 534 521 522 523 524 525 526

3 540 554 541 542 543 544 545 546

1

Select days

Selection of days or groups of days for time program

1 1 1 1 1 1 1

Select default timings? 1st Time ON 1st Time OFF 2nd Time ON 2nd Time OFF 3rd Time ON 3rd Time OFF

Is it possibile to select up to 3 preselect time programs

516

536

556

1

Default values

Parameter

TIME HOT WATER

1 1 1 1 1 1 1 1

Select days Select default timings? 1st Time ON 1st Time OFF 2nd Time ON 2nd Time OFF 3rd Time ON 3rd Time OFF

576

1

Default values

Default Defau lt

Yes No

Level

TIME AUXILIARY

1 1 1 1 1 1 1 1

Select days Select default timings? 1st Time ON 1st Time OFF 2nd Time ON 2nd Time OFF 3rd Time ON 3rd Time OFF

616

1

Default values

Yes No

Level

Def au l t

Selection of days or groups of days for time program Is it possibile to select up to 3 preselect time programs

600 614 601 602 603 604 605 606

Parameter

Default

Yes No

Level

560 574 561 562 563 564 565 566

Parameter

Default

Displayed if the control panel is configured as room unit Displayed if the control panel is configured as room unit Displayed if the control panel is configured as room unit

Default

Selection of days or groups of days for time program Is it possibile to select up to 3 preselect time programs

HOL IDA Y HEA TING 1 – 2 – 3

1 641 642 643

2 651 652 653

3 661 662 663

1

Select

Is it possibile to select up to 8 holiday periods

1 1

Start End

648

658

668

1

Operating level

Day and month of holiday start Day and month of holiday end Off Reduced

Def au l t

131 132 133 134 135 140

2 2 2 2 2 2

Parameter

Room unit 2 Room unit 3 Outside sensor Repeater Operator unit Delete all devices

Check of link Check of link Check of link Check of link Check of link

Level

TIME CENTRA L HEATING 1 – 2 – 3

1 500 514 501 502 503 504 505 506

2 520 534 521 522 523 524 525 526

3 540 554 541 542 543 544 545 546

1

Select days

Selection of days or groups of days for time program

1 1 1 1 1 1 1

Select default timings? 1st Time ON 1st Time OFF 2nd Time ON 2nd Time OFF 3rd Time ON 3rd Time OFF

Is it possibile to select up to 3 preselect time programs

516

536

556

1

Default values

Parameter

Yes No

Level

TIME HOT WATER

560 574 561 562 563 564 565 566

1 1 1 1 1 1 1 1

Select days Select default timings? 1st Time ON 1st Time OFF 2nd Time ON 2nd Time OFF 3rd Time ON 3rd Time OFF

576

1

Default values

Parameter

Yes No

Level

TIME AUXILIARY

1 1 1 1 1 1 1 1

Select days Select default timings? 1st Time ON 1st Time OFF 2nd Time ON 2nd Time OFF 3rd Time ON 3rd Time OFF

616

1

Default values

Yes No

Level

Default Defau lt

Selection of days or groups of days for time program Is it possibile to select up to 3 preselect time programs

600 614 601 602 603 604 605 606

Parameter

Def au l t

Default

Selection of days or groups of days for time program Is it possibile to select up to 3 preselect time programs

HOL IDA Y HEA TING 1 – 2 – 3

1 641 642 643

2 651 652 653

3 661 662 663

1

Select

Is it possibile to select up to 8 holiday periods

1 1

Start End

648

658

668

1

Operating level

Day and month of holiday start Day and month of holiday end Off Reduced

Def au l t

2463

3

Settling time HW

2670

3

Parameter

2672 2675 2681 2682

3 3 3 3

Parameter Parameter Parameter Parameter

Parameter 

3 3 3 3

Ion current filtered Position stepper motor Learning value gas quality Operating phase

2720

2

Release sel type of gas

2721

2

Type of gas

2725

3

Sel individual boiler setting

2726 2729

3 3

Ind boil setting ion curr LF Ind boil setting ion curr HF

2740

3

Triggering drift test

2741 2742 2743 2744 2745 2746 2747 2748 2749

3 3 3 3 3 3 3 3 3

Parameter Parameter Parameter Parameter Parameter Parameter Parameter Parameter Reset drift test

3510

SITHERM PRO

Default

Ionization current actual value Gas valve stepper motor position Gas calorific power measurement Release of ga type selection: 0 Off 1 On Type of gas: 1 Natural gas 2 Liquefied gas  Activation of combustion adjustment: Off Set low-fire ion current  Activation of correction at low power Save low-fire ion current Stored of correction at low power Set high-fire ion current  Activation of correction at high power Save high-fire ion current Stored of correction at high power  Setting of correction at low power Setting of correction at high power Manual test of combustion adjustment: 0 Disabled 1 Test done at high and low power 2 Test done only at high power 3 Test done only at low power 4 Test done at high and low power alternatively for 3 times Last test result at low power Last test filtred result at low power Correction at low power Threshold of correction at low power Last test result at high power Last test filtred result at high power Correction at high power Threshold of correction at high power Reset of correction results

CASCADE Lead strategy

On

Precirculation time on DHW way (3WV position) during precirculation function Precirculation time on CH way (3WV position) during precirculation function

Level 3

1min

30°C Table1 Table1 Table1

L e v el

2700 2702 2703 2706

Parameter 

Validity time of parameter 2462  Activation of Super Over Temperature Function (SOT): On Off Increase of boiler setpoint for the control of SOT

Lead strategy:

Off Natural gas

Off

0uA 0uA

0

No Default Late on, late off

2463

3

Settling time HW

2670

3

Parameter

2672 2675 2681 2682

3 3 3 3

Parameter Parameter Parameter Parameter

Parameter 

3 3 3 3

Ion current filtered Position stepper motor Learning value gas quality Operating phase

2720

2

Release sel type of gas

2721

2

Type of gas

2725

3

Sel individual boiler setting

2726 2729

3 3

Ind boil setting ion curr LF Ind boil setting ion curr HF

2740

3

Triggering drift test

2741 2742 2743 2744 2745 2746 2747 2748 2749

3 3 3 3 3 3 3 3 3

Parameter Parameter Parameter Parameter Parameter Parameter Parameter Parameter Reset drift test

3510

SITHERM PRO

Default

Ionization current actual value Gas valve stepper motor position Gas calorific power measurement Release of ga type selection: 0 Off 1 On Type of gas: 1 Natural gas 2 Liquefied gas  Activation of combustion adjustment: Off Set low-fire ion current  Activation of correction at low power Save low-fire ion current Stored of correction at low power Set high-fire ion current  Activation of correction at high power Save high-fire ion current Stored of correction at high power  Setting of correction at low power Setting of correction at high power Manual test of combustion adjustment: 0 Disabled 1 Test done at high and low power 2 Test done only at high power 3 Test done only at low power 4 Test done at high and low power alternatively for 3 times Last test result at low power Last test filtred result at low power Correction at low power Threshold of correction at low power Last test result at high power Last test filtred result at high power Correction at high power Threshold of correction at high power Reset of correction results

CASCADE Lead strategy

On

Precirculation time on DHW way (3WV position) during precirculation function Precirculation time on CH way (3WV position) during precirculation function

Level 3

1min

30°C Table1 Table1 Table1

L e v el

2700 2702 2703 2706

Parameter 

Validity time of parameter 2462  Activation of Super Over Temperature Function (SOT): On Off Increase of boiler setpoint for the control of SOT

Lead strategy:

Off Natural gas

Off

0uA 0uA

0

No Default Late on, late off

5040

3

Discharging protection

5050 5051 5055

3 3 3

Charging temp max Storage tank temp max Recooling temp

5056

3

Recooling heat gen/CHs

5057

3

Recooling collector

5060

3

El imm heater optg mode

5061

3

El immersion heater release

5062

3

El immersion heater control

5070

3

Hot water boost

5071

3

Charging prio time push

5085

3

Excess heat draw

5090

3

With buffer

5092

3

With prim contr/system pump

5093

3

With solar integration

Parameter 

Level

 Attivazione della pompa Q3 in caso di temperatura di mandata troppo alta This function ensures ensures that the DHW charging pump (Q3) is activated only when the heat source temperature is high enough: Off Disabled  Always Enabled Timed  Active only if the heat source is not able to supply heat or if it is not available Maximum charging temperature from solar collector Maximum hot water tank temperature Recooling hot water tank temperature Tank recooling through heating circuit: On Off Tank recooling through solar collector: Off Summer  Always Electric immersion heater used for DHW tank: Substitute The electric immersion heater is only used if the boiler delivers a fault status message or has been shut down via boiler l ock. Summer The electric immersion heater is used when all connected heating circuits have switched to summer operation. The DHW is again heated by the boiler as soon as at least one of the heating circuits has switched back to Heating mode. But the electric immersion heater is also used if the boiler delivers a fault status message or has been shut down via boiler lock.  Always DHW is always heated with the electric immersion heater  Electric immersion heater release: 24h/day Hot water release Time hot water Electric immersion heater control mode: External thermostat Hot water sensor If the DHW temperature drops by more than 2 switching differentials (l5024) below the Reduced setpoint: On Off The DHW storage tank is charged with absolute priority during the set period of time Surplus heat can be fed to the DHW storage tank: On Off DHW storage tank receives its heat via buffer storage tank: Yes No DHW storage tank receives its heat via the primary controller or with the help of the system pump: Yes No DHW storage tank receives its heat from the solar collectors: Yes No

INSTANTANEOUS HW HEATER

Timed

65°C 90°C 80°C Off

Off 

Substitute

Hot water release

Hot water sensor 

On 0min On

No

No

Yes

Default Defau lt

5040

3

Discharging protection

5050 5051 5055

3 3 3

Charging temp max Storage tank temp max Recooling temp

5056

3

Recooling heat gen/CHs

5057

3

Recooling collector

5060

3

El imm heater optg mode

5061

3

El immersion heater release

5062

3

El immersion heater control

5070

3

Hot water boost

5071

3

Charging prio time push

5085

3

Excess heat draw

5090

3

With buffer

5092

3

With prim contr/system pump

5093

3

With solar integration

Parameter 

Level

 Attivazione della pompa Q3 in caso di temperatura di mandata troppo alta This function ensures ensures that the DHW charging pump (Q3) is activated only when the heat source temperature is high enough: Off Disabled  Always Enabled Timed  Active only if the heat source is not able to supply heat or if it is not available Maximum charging temperature from solar collector Maximum hot water tank temperature Recooling hot water tank temperature Tank recooling through heating circuit: On Off Tank recooling through solar collector: Off Summer  Always Electric immersion heater used for DHW tank: Substitute The electric immersion heater is only used if the boiler delivers a fault status message or has been shut down via boiler l ock. Summer The electric immersion heater is used when all connected heating circuits have switched to summer operation. The DHW is again heated by the boiler as soon as at least one of the heating circuits has switched back to Heating mode. But the electric immersion heater is also used if the boiler delivers a fault status message or has been shut down via boiler lock.  Always DHW is always heated with the electric immersion heater  Electric immersion heater release: 24h/day Hot water release Time hot water Electric immersion heater control mode: External thermostat Hot water sensor If the DHW temperature drops by more than 2 switching differentials (l5024) below the Reduced setpoint: On Off The DHW storage tank is charged with absolute priority during the set period of time Surplus heat can be fed to the DHW storage tank: On Off DHW storage tank receives its heat via buffer storage tank: Yes No DHW storage tank receives its heat via the primary controller or with the help of the system pump: Yes No DHW storage tank receives its heat from the solar collectors: Yes No

INSTANTANEOUS HW HEATER

5464

2

Hot water preheat release

5470 5476 5482 5490 5491

1 3 3 3 3

HW preheat time when no CH Keep hot periodically Flow switch time cons Parameter Parameter

Parameter 

Level

5710

2

Temps / mode CH1

5711

3

Cooling circuit 1

5715

2

Temps / mode CH2

5721

2

Temps / mode CH3

5730

2

Hot water sensor

5731

2

HW controlling element

5732 5733

3 3

Pump off change div valve Delay pump off

5734

3

Basic pos HW div valve

5736

3

Hot water separate circuit

5737

3

Optg action HW div valve

5738

3

Midposition DHW div valve

5774

3

Ctrl boiler pump/HW valve

Preheat mode: 24h/day Hot water release Time central heating CH3 Time hot water Time auxiliary Preheat time Duration time of preheat function Minimum response time of the flow switch for detecting consumption

CONFIGURATION Heating circuit 1 activation: 0 Off 1 On Cooling circuit 1 activation: Off 4-pipe system cooling Heating circuit 2 activation: 0 Off 1 On Heating circuit 3 activation: Off On DHW sensor selection: 1 Hot water sensor B3 DHW storage tank sensor 2 Thermostat Sensor used as DHW thermostat 3 HW outlet sensor B38 Instantaneous water heater outlet sensor   Actuator type for DHW request control: No charging request No function Charging pump  Actuator used as charging pump Diverting valve  Actuator used as diverting valve Set the time the pumps are deactivated when the diverti ng valve switches over Set the delay time for the pumps to be deactivated after the diverting valve has switched over Default DHW diverting valve position: Last request Central heating Default for boiler with DHW tank Hot water Default for instantaneous water heater boiler  The DHW separate circuit can only be employed in a cascaded system: On Off The diverting valve position selected here is the position used when the output is active: Position on HW Position on CH DHW diverting valve can be driven to the mid-position: On Off  Activation mode of boiler pump and DHW diverting valve:  All requests Request CH1/HW only

Timed

65°C 90°C 80°C Off

Off 

Substitute

Hot water release

Hot water sensor 

On 0min On

No

No

Yes

Default Defau lt

Time hot water 

Table1 Table1 1s Table1 Off

Default On

Off

Off

Off

Table1

Diverting valve 0s 0s Table1

Off

Position on HW

Off

 All requests

5464

2

Hot water preheat release

5470 5476 5482 5490 5491

1 3 3 3 3

HW preheat time when no CH Keep hot periodically Flow switch time cons Parameter Parameter

Parameter 

Level

Preheat mode: 24h/day Hot water release Time central heating CH3 Time hot water Time auxiliary Preheat time Duration time of preheat function Minimum response time of the flow switch for detecting consumption

CONFIGURATION Heating circuit 1 activation: 0 Off 1 On Cooling circuit 1 activation: Off 4-pipe system cooling Heating circuit 2 activation: 0 Off 1 On Heating circuit 3 activation: Off On DHW sensor selection: 1 Hot water sensor B3 DHW storage tank sensor 2 Thermostat Sensor used as DHW thermostat 3 HW outlet sensor B38 Instantaneous water heater outlet sensor   Actuator type for DHW request control: No charging request No function Charging pump  Actuator used as charging pump Diverting valve  Actuator used as diverting valve Set the time the pumps are deactivated when the diverti ng valve switches over Set the delay time for the pumps to be deactivated after the diverting valve has switched over Default DHW diverting valve position: Last request Central heating Default for boiler with DHW tank Hot water Default for instantaneous water heater boiler  The DHW separate circuit can only be employed in a cascaded system: On Off The diverting valve position selected here is the position used when the output is active: Position on HW Position on CH DHW diverting valve can be driven to the mid-position: On Off  Activation mode of boiler pump and DHW diverting valve:  All requests Request CH1/HW only

5710

2

Temps / mode CH1

5711

3

Cooling circuit 1

5715

2

Temps / mode CH2

5721

2

Temps / mode CH3

5730

2

Hot water sensor

5731

2

HW controlling element

5732 5733

3 3

Pump off change div valve Delay pump off

5734

3

Basic pos HW div valve

5736

3

Hot water separate circuit

5737

3

Optg action HW div valve

5738

3

Midposition DHW div valve

5774

3

Ctrl boiler pump/HW valve

5840

3

Solar controlling element

5841

3

External solar exchanger

5870

3

Combi storage tank

5890

2

Relay output QX1

5891

3

Relay output QX2

See relay output QX1

5892

3

Relay output QX3

See relay output QX1

 Actuator configuration in case of solar storage tanks: Charging pump Used as charging pump Diverting valve Used as diverting valve In the case of solar plant diagrams with 2 storage tanks, it must be selected whether there is an external heat exchanger for both the DHW and the buffer storage tank or for only one of them.: Commonly Hot water storage tank Buffer storage tank Functions specific to combi storage tanks are activated via this setting (for example, the electric immersion heater installed in the buffer storage tank can be used for both space heating and DHW heating): Yes No 0 None 1 Circulating pump Q4 DHW circulating pump 2 El imm heater HW K6 3 Collector pump Q5 Solar collector pump 4 Cons circuit pump VK1 Q15 Consumer circuit 1 pump 5 Boiler pump Q1 Boiler pump 6 Bypass pump Q12 7 Alarm output K10  Alarm relay signals faults 8 2nd pump speed CH1 Q21 9 2nd pump speed CH2 Q22 10 2nd pump speed CH3 Q23 11 heating pump CH3 Q20 Pump/zone valve for heating circuit 3 12 Cons circuit pump VK2 Q18 13 System pump Q14 Pump activated at every heat request from consumer circuits 14 Heat gen shutoff valve Y4 15 Solid fuel boiler pump Q10 Solid flue boiler pump 16 Time setting 5 K13 The relay is controlled according to setting made in “time auxiliary program” 17 Buffer return valve Y15 18 Solar pump ext exch K9 19 Solar ctrl elem buffer K8 20 Solar ctrl elem swi pool K18 Contact to heat swimming pool by solar (in case of several heat exchangers) 22 Swimming pool pump Q19 25 Cascade pump Q25 Common cascade pump 26 St tank transfer pump Q11 27 Hot water mixing pump Q35 28 HW interm circ pump Q33 29 Heat request K27 30 Refrigeration request K28 Cooling request from cooling circuit 1 33 Heating pump CH1 Q2 Pump/zone valve for heating circuit 1 34 Heating pump CH2 Q6 Pump/zone valve for heating circuit 2 35 Hot water ctrl elem Q3 Pump/diverting valve for DHW tank 36 Instant WH ctrl elem Q34 Pump/diverting valve for instantaneous DHW production 38 Water refill K34 Water refill electrovalve 39 2nd boiler pump speed Q27 2nd boiler pump speed 40 Status output K35 41 Status information K36 42 Flue gas damper K37 43 Fan shutdown K38 External fan control

Time hot water 

Table1 Table1 1s Table1 Off

Default On

Off

Off

Off

Table1

Diverting valve 0s 0s Table1

Off

Position on HW

Off

 All requests

Charging pump

Commonly

No

heating pump CH1 Q2

Boiler pump Q1 Table1

 Actuator configuration in case of solar storage tanks: Charging pump Used as charging pump Diverting valve Used as diverting valve In the case of solar plant diagrams with 2 storage tanks, it must be selected whether there is an external heat exchanger for both the DHW and the buffer storage tank or for only one of them.: Commonly Hot water storage tank Buffer storage tank Functions specific to combi storage tanks are activated via this setting (for example, the electric immersion heater installed in the buffer storage tank can be used for both space heating and DHW heating): Yes No 0 None 1 Circulating pump Q4 DHW circulating pump 2 El imm heater HW K6 3 Collector pump Q5 Solar collector pump 4 Cons circuit pump VK1 Q15 Consumer circuit 1 pump 5 Boiler pump Q1 Boiler pump 6 Bypass pump Q12 7 Alarm output K10  Alarm relay signals faults 8 2nd pump speed CH1 Q21 9 2nd pump speed CH2 Q22 10 2nd pump speed CH3 Q23 11 heating pump CH3 Q20 Pump/zone valve for heating circuit 3 12 Cons circuit pump VK2 Q18 13 System pump Q14 Pump activated at every heat request from consumer circuits 14 Heat gen shutoff valve Y4 15 Solid fuel boiler pump Q10 Solid flue boiler pump 16 Time setting 5 K13 The relay is controlled according to setting made in “time auxiliary program” 17 Buffer return valve Y15 18 Solar pump ext exch K9 19 Solar ctrl elem buffer K8 20 Solar ctrl elem swi pool K18 Contact to heat swimming pool by solar (in case of several heat exchangers) 22 Swimming pool pump Q19 25 Cascade pump Q25 Common cascade pump 26 St tank transfer pump Q11 27 Hot water mixing pump Q35 28 HW interm circ pump Q33 29 Heat request K27 30 Refrigeration request K28 Cooling request from cooling circuit 1 33 Heating pump CH1 Q2 Pump/zone valve for heating circuit 1 34 Heating pump CH2 Q6 Pump/zone valve for heating circuit 2 35 Hot water ctrl elem Q3 Pump/diverting valve for DHW tank 36 Instant WH ctrl elem Q34 Pump/diverting valve for instantaneous DHW production 38 Water refill K34 Water refill electrovalve 39 2nd boiler pump speed Q27 2nd boiler pump speed 40 Status output K35 41 Status information K36 42 Flue gas damper K37 43 Fan shutdown K38 External fan control

5840

3

Solar controlling element

5841

3

External solar exchanger

5870

3

Combi storage tank

5890

2

Relay output QX1

5891

3

Relay output QX2

See relay output QX1

5892

3

Relay output QX3

See relay output QX1

Charging pump

Commonly

No

heating pump CH1 Q2

Boiler pump Q1 Table1

6051 6052 6054

2 2 2

Voltage value 2 H2 module 1 Funct value 2 H2 module 1 Function input H2 module 2

6055

2

Contact type H2 module 2

6057 6058 6059 6060 6062

2 2 2 2 2

Voltage value 1 H2 module 2 Funct value 1 H2 module 2 Voltage value 2 H2 module 2 Funct value 2 H2 module 2 Function input H2 module 3

6063

2

Contact type H2 module 3

6065 6066 6067 6068

2 2 2 2

Voltage value 1 H2 module 3 Funct value 1 H2 module 3 Voltage value 2 H2 module 3 Funct value 2 H2 module 3

6097

2

Sensor type collector

6098 6100 6110

3 2 3

Readjustm collector sensor Readjustm outside sensor Time constant building

6120

3

System frost protection

6200 6205 6212 6213 6215 6217 6220 6230 6231

2 3 2 2 2 2 3 2 2

Save sensors Reset to default parameters Check no. heat source 1 Check no. heat source 2 Check no. storage tank Check no. heating circuits Software version Info 1 OEM Info 2 OEM

Parameter 

Level

Parameter for characteristic definition of sensor Parameter for characteristic definition of sensor See function input H1 NO NC Parameter for characteristic definition of sensor Parameter for characteristic definition of sensor Parameter for characteristic definition of sensor Parameter for characteristic definition of sensor See function input H1 NO NC Parameter for characteristic definition of sensor Parameter for characteristic definition of sensor Parameter for characteristic definition of sensor Parameter for characteristic definition of sensor Solar collector sensor type: 1 NTC 2 PT1000 Correction of readed collector sensor value Correction of readed outside sensor value Time thermic constant building Plant frost protection (only with outside sensor): On Off Stored of sensor used in plant Not used Manufactoring information Manufactoring information Manufactoring information Manufactoring information Manufactoring information Manufactoring information Manufactoring information

LPB SYST SYSTEM EM

6600 6601

3 3

Device address Segment address

6604

3

Bus power supply function

6605

3

Bus power supply state

6610

3

Display system messages

6612

3

 Alarm delay

6620

3

 Action changeover functions

Choice of cascade device address from 1 to 16 (1 = master) Choice of cascade segment from 0 to 14 Bus power supply type: Off Timed Bus power supply state: On Off Visualization of system messages: Yes No  Alarm time delay  Action function changeover: System Segment

0V 0 None NO 0V 0 0V 0 None NO 0V 0 0V 0 PT1000 0°C 0°C 15h Off No No

Table1

Default 1 0 Timed

No --System

6051 6052 6054

2 2 2

Voltage value 2 H2 module 1 Funct value 2 H2 module 1 Function input H2 module 2

6055

2

Contact type H2 module 2

6057 6058 6059 6060 6062

2 2 2 2 2

Voltage value 1 H2 module 2 Funct value 1 H2 module 2 Voltage value 2 H2 module 2 Funct value 2 H2 module 2 Function input H2 module 3

6063

2

Contact type H2 module 3

6065 6066 6067 6068

2 2 2 2

Voltage value 1 H2 module 3 Funct value 1 H2 module 3 Voltage value 2 H2 module 3 Funct value 2 H2 module 3

6097

2

Sensor type collector

6098 6100 6110

3 2 3

Readjustm collector sensor Readjustm outside sensor Time constant building

6120

3

System frost protection

6200 6205 6212 6213 6215 6217 6220 6230 6231

2 3 2 2 2 2 3 2 2

Save sensors Reset to default parameters Check no. heat source 1 Check no. heat source 2 Check no. storage tank Check no. heating circuits Software version Info 1 OEM Info 2 OEM

Parameter 

Level

Parameter for characteristic definition of sensor Parameter for characteristic definition of sensor See function input H1 NO NC Parameter for characteristic definition of sensor Parameter for characteristic definition of sensor Parameter for characteristic definition of sensor Parameter for characteristic definition of sensor See function input H1 NO NC Parameter for characteristic definition of sensor Parameter for characteristic definition of sensor Parameter for characteristic definition of sensor Parameter for characteristic definition of sensor Solar collector sensor type: 1 NTC 2 PT1000 Correction of readed collector sensor value Correction of readed outside sensor value Time thermic constant building Plant frost protection (only with outside sensor): On Off Stored of sensor used in plant Not used Manufactoring information Manufactoring information Manufactoring information Manufactoring information Manufactoring information Manufactoring information Manufactoring information

LPB SYST SYSTEM EM

6600 6601

3 3

Device address Segment address

6604

3

Bus power supply function

6605

3

Bus power supply state

6610

3

Display system messages

6612

3

 Alarm delay

6620

3

 Action changeover functions

6621

3

Summer changeover

6623

3

Optg mode changeover

6624

3

Manual source lock

6625

3

Hot water assignment

6630

3

Cascade master

6631

3

Ext source with eco mode

6632

3

Note OT limit ext source

6640

3

Clock mode

6650

3

Outside temp source

Parameter 

Level

6704

2

Display SW diagnostic code

6705 6706 6710 6740 6741 6742 6743 6745 6800 6805 6806 6810 - 6996

1 1 2 3 3 3 3 3 2 2 2 2

SW diagnostic code Burn ctrl phase lockout pos Reset alarm relay Flow temp 1 alarm Flow temp 2 alarm Flow temp 3 alarm Boiler temp alarm Hot water charging alarm History 1 SW diagnostic code 1 Burner control phase 1 History from 2 to 20

Parameter 

Level

7040

3

Choice of cascade device address from 1 to 16 (1 = master) Choice of cascade segment from 0 to 14 Bus power supply type: Off Timed Bus power supply state: On Off Visualization of system messages: Yes No  Alarm time delay  Action function changeover: System Segment

Summer changeover: Locally Centrally Option mode changeover: Locally Centrally Lock mode: Locally Segment DHW assignment: Local CHs DHW used the setting of boiler  All CHs in segment DHW used the setting of boiler in same cascade segment  All CHs in system DHW used the setting of boiler in cascade system Cascade master:  Always Cascade master is the boiler also if address is not 1  Automatically Cascade master is the boiler with address 1 In ECO mode, external heat sources on the LPB are operated as follows: Off On hot water On External heat sources can be locked or released according to their own parameters, based on the outside temperature: Yes No Clock mode:  Autonomously Every boiler has own time program Slave without remote setting Slave boilers not use the master time program Slave with remote setting Slave boilers use the master time program Master The master time program is used Boiler address where is connected outside sensor: - - . - - no outside sensor connected The first 2 numbers are hte segment number, the second part is the boiler number 

FAULT Visualization of diagnostic code: 0 No 1 Yes Diagnostic code currently pending Lockout phase indicating where the fault occured Reset of alarm relay value displayed value displayed value displayed value displayed value displayed Last fault occured Diagnostic code of last fault occured Lockout phase indicating where the last fault occured Previous fault history

SERVICE/SPECIAL SERVICE/SPEC IAL OPERATION Burner hours interval

Burner hours before boiler maintenance

0V 0 None NO 0V 0 0V 0 None NO 0V 0 0V 0 PT1000 0°C 0°C 15h Off No No

Table1

Default 1 0 Timed

No --System

Locally

Centrally

Segment

 All CHs in system

 Automatically

Off

No

 Autonomously

Default Yes

No -----------

Default Defau lt ---

Summer changeover: Locally Centrally Option mode changeover: Locally Centrally Lock mode: Locally Segment DHW assignment: Local CHs DHW used the setting of boiler  All CHs in segment DHW used the setting of boiler in same cascade segment  All CHs in system DHW used the setting of boiler in cascade system Cascade master:  Always Cascade master is the boiler also if address is not 1  Automatically Cascade master is the boiler with address 1 In ECO mode, external heat sources on the LPB are operated as follows: Off On hot water On External heat sources can be locked or released according to their own parameters, based on the outside temperature: Yes No Clock mode:  Autonomously Every boiler has own time program Slave without remote setting Slave boilers not use the master time program Slave with remote setting Slave boilers use the master time program Master The master time program is used Boiler address where is connected outside sensor: - - . - - no outside sensor connected The first 2 numbers are hte segment number, the second part is the boiler number 

6621

3

Summer changeover

6623

3

Optg mode changeover

6624

3

Manual source lock

6625

3

Hot water assignment

6630

3

Cascade master

6631

3

Ext source with eco mode

6632

3

Note OT limit ext source

6640

3

Clock mode

6650

3

Outside temp source

Parameter 

Level

6704

2

Display SW diagnostic code

6705 6706 6710 6740 6741 6742 6743 6745 6800 6805 6806 6810 - 6996

1 1 2 3 3 3 3 3 2 2 2 2

SW diagnostic code Burn ctrl phase lockout pos Reset alarm relay Flow temp 1 alarm Flow temp 2 alarm Flow temp 3 alarm Boiler temp alarm Hot water charging alarm History 1 SW diagnostic code 1 Burner control phase 1 History from 2 to 20

Visualization of diagnostic code: 0 No 1 Yes Diagnostic code currently pending Lockout phase indicating where the fault occured Reset of alarm relay value displayed value displayed value displayed value displayed value displayed Last fault occured Diagnostic code of last fault occured Lockout phase indicating where the last fault occured Previous fault history

Parameter 

Level

7040

3

Burner hours interval

Burner hours before boiler maintenance

7041 7042 7043 7044 7045 7051

3 3 3 3 2 3

Burn hrs since maintenance Burner start interval Burn starts since maint Maintenance interval Time since maintenance Message ionization current

7130

2

Chimney sweep function

7131

2

Burner output

7140

2

Manual control

7143

2

Controller stop function

7145

2

Controller stop setpoint

7146

2

Deaeration function

7147

2

Type of venting

Burner hours reset after boiler maintenance Burner ignition number before boiler maintenance Burner ignition number reset after boiler maintenance Operation boiler time before boiler maintenance Operation boiler time reset after boiler maintenance Ionization current value Chimney swwp function: On Off Burner output power during chimney sweep function: Partial load Full load Max heating load Manual control function: On Off Controller stop function: On Off Power setpoint during controller stop function Deaeration function: On Off Deaeration function mode: None Heating circuit continuous Heating circuit cycled Hot water continuous Hot water cycled

7170 7231 7232 7233

2 2 2 2

Telephone customer service Refilll time current week Refill time to date Number of refills to date

7244

3

Press superv water refill

7250 7251

3 3

PStick storage pos Parameter

7252

3

PStick command

7253

3

PStick progress

7254

3

Parameter

FAULT

SERVICE/SPECIAL SERVICE/SPEC IAL OPERATION

Locally

Centrally

Segment

 All CHs in system

 Automatically

Off

No

 Autonomously

Default Yes

No -----------

Default Defau lt ---

0h --O --0Month No Off

Max heating load

Off

Off 100% Off

None

0 value displayed value displayed value displayed Used sensor for water pressure supervision for refill function: None With input H1 With input H2 module 1 With input H2 module 2 With input H2 module 3 With input H3 Selection of the dataset number to write/read Description of dataset selected  Actions with Pstick: No operation Reading from stick Writing on stick The progress made appears as a percentage which, when stick operation is active (reading or writing) shows the percentage already completed. Status of Pstick: No stick No operation Writing on stick

None

7041 7042 7043 7044 7045 7051

3 3 3 3 2 3

Burn hrs since maintenance Burner start interval Burn starts since maint Maintenance interval Time since maintenance Message ionization current

7130

2

Chimney sweep function

7131

2

Burner output

7140

2

Manual control

7143

2

Controller stop function

7145

2

Controller stop setpoint

7146

2

Deaeration function

7147

2

Type of venting

7170 7231 7232 7233

2 2 2 2

Telephone customer service Refilll time current week Refill time to date Number of refills to date

7244

3

Press superv water refill

7250 7251

3 3

PStick storage pos Parameter

7252

3

PStick command

7253

3

PStick progress

7254

3

Parameter

Burner hours reset after boiler maintenance Burner ignition number before boiler maintenance Burner ignition number reset after boiler maintenance Operation boiler time before boiler maintenance Operation boiler time reset after boiler maintenance Ionization current value Chimney swwp function: On Off Burner output power during chimney sweep function: Partial load Full load Max heating load Manual control function: On Off Controller stop function: On Off Power setpoint during controller stop function Deaeration function: On Off Deaeration function mode: None Heating circuit continuous Heating circuit cycled Hot water continuous Hot water cycled

0h --O --0Month No Off

Max heating load

Off

Off 100% Off

None

0 value displayed value displayed value displayed Used sensor for water pressure supervision for refill function: None With input H1 With input H2 module 1 With input H2 module 2 With input H2 module 3 With input H3 Selection of the dataset number to write/read Description of dataset selected  Actions with Pstick: No operation Reading from stick Writing on stick The progress made appears as a percentage which, when stick operation is active (reading or writing) shows the percentage already completed. Status of Pstick: No stick No operation Writing on stick

None

Reading from stick EMC test active Writing error Reading error Incompatible data set Wrong stick type Stick format error Check data set Data set disabled Reading disabled

Parameter 

Level

INPUT/OUTPUT TEST

7700

3

Relay test

7730 7750 7760 7820 7821 7822 7830 7831 7832 7833 7834 7835 7840 7841 7845 7846 7848 7849 7851 7852 7862 7860 7865

3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

Outside temp B9 Hot waterr temp B3 Boiler temp B2 Sensor temp BX1 Sensor temp BX2 Sensor temp BX3 Sensor temp BX21 module 1 Sensor temp BX22 module 1 Sensor temp BX21 module 2 Sensor temp BX22 module 2 Sensor temp BX21 module 3 Sensor temp BX22 module 3 Voltage signal H1 Contact state H1 Voltage signal H2 Contact state H2 Voltage signal H2 module 2 Contact state H2 module 2 Voltage signal H2 module 3 Contact state H2 module 3 Frequency H4 Contact state H4 Contact state H5

Operatin relays test: No test Everything off Relay output QX1 Relay output QX2 Relay output QX3 Relay output QX4 Relay output QX21 module 1 Relay output QX21 module 2 Relay output QX21 module 3 Relay output QX22 module 1 Relay output QX22 module 2 Relay output QX22 module 3 Relay output QX23 module 1 Relay output QX23 module 2 Relay output QX23 module 3 value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed

Default Defau lt

No test

Reading from stick EMC test active Writing error Reading error Incompatible data set Wrong stick type Stick format error Check data set Data set disabled Reading disabled

Parameter 

Level

INPUT/OUTPUT TEST

7700

3

Relay test

7730 7750 7760 7820 7821 7822 7830 7831 7832 7833 7834 7835 7840 7841 7845 7846 7848 7849 7851 7852 7862 7860 7865

3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

Outside temp B9 Hot waterr temp B3 Boiler temp B2 Sensor temp BX1 Sensor temp BX2 Sensor temp BX3 Sensor temp BX21 module 1 Sensor temp BX22 module 1 Sensor temp BX21 module 2 Sensor temp BX22 module 2 Sensor temp BX21 module 3 Sensor temp BX22 module 3 Voltage signal H1 Contact state H1 Voltage signal H2 Contact state H2 Voltage signal H2 module 2 Contact state H2 module 2 Voltage signal H2 module 3 Contact state H2 module 3 Frequency H4 Contact state H4 Contact state H5

Operatin relays test: No test Everything off Relay output QX1 Relay output QX2 Relay output QX3 Relay output QX4 Relay output QX21 module 1 Relay output QX21 module 2 Relay output QX21 module 3 Relay output QX22 module 1 Relay output QX22 module 2 Relay output QX22 module 3 Relay output QX23 module 1 Relay output QX23 module 2 Relay output QX23 module 3 value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed

7950 7951 7952

3 3 3

Input EX21 module 1 Input EX21 module 2 Input EX21 module 3

value displayed value displayed value displayed

Parameter  8000 8001 8002 8003 8005 8007 8008 8009 8010 8011 8023

Parameter  8100 8101 8102 8103 8104 8105 8106 8107 8108 8109 8110 8111 8112 8113 8114 8115 8116 8117 8118 8119 8120 8121 8122 8123 8124 8125 8126 8127 8128 8129 8130

Level 2 2 2 2 2 2 2 2 2 2 2

No test

STATE

Default

DIAGNOSTIC CASCADE

Default Defau lt

State central heating CH1 State central heating CH2 State central heating CH3 State hot water State boiler State solar State solid fuel boiler State burner State buffer State swimming pool State SithermPro

Level 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

Default Defau lt

Priority/state source 1 Priority/state source 2 Priority/state source 3 Priority/state source 4 Priority/state source 5 Priority/state source 6 Priority/state source 7 Priority/state source 8 Priority/state source 9 Priority/state source 10 Priority/state source 11 Priority/state source 12 Priority/state source 13 Priority/state source 14 Priority/state source 15 Priority/state source 16

value displayed state displayed value displayed state displayed value displayed state displayed value displayed state displayed value displayed state displayed value displayed state displayed value displayed state displayed value displayed state displayed value displayed state displayed value displayed state displayed value displayed state displayed value displayed state displayed value displayed state displayed value displayed state displayed value displayed state displayed value displayed

7950 7951 7952

Parameter  8000 8001 8002 8003 8005 8007 8008 8009 8010 8011 8023

Parameter 

3 3 3

2 2 2 2 2 2 2 2 2 2 2

8131 8138 8139 8140 8141 8150

3 3 3 3 3 3

Parameter 

Priority/state source 1

Priority/state source 16

value displayed state displayed value displayed state displayed value displayed state displayed value displayed state displayed value displayed state displayed value displayed state displayed value displayed state displayed value displayed state displayed value displayed state displayed value displayed state displayed value displayed state displayed value displayed state displayed value displayed state displayed value displayed state displayed value displayed state displayed value displayed

Cascade flow temp Cascade flow temp setp Cascade return temp Cascade return temp setp Source seq ch'over current

state displayed value displayed value displayed value displayed value displayed value displayed

Priority/state source 2 Priority/state source 3 Priority/state source 4 Priority/state source 5 Priority/state source 6 Priority/state source 7 Priority/state source 8 Priority/state source 9 Priority/state source 10 Priority/state source 11 Priority/state source 12 Priority/state source 13 Priority/state source 14 Priority/state source 15

Level 3 3 2 2 3 3 2 2 2 3 2 2 3 3 2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 1 1 1 1 3 3

Level

STATE

Default

DIAGNOSTIC CASCADE

Default Defau lt

DIAGNOSTICS HEAT GENERATION

Default Defau lt

DIAGNOSTICS CONSUMER CONSUMERS S

Default Defau lt

State central heating CH1 State central heating CH2 State central heating CH3 State hot water State boiler State solar State solid fuel boiler State burner State buffer State swimming pool State SithermPro

Level 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

8304 8308 8310 8311 8312 8313 8314 8315 8316 8318 8321 8323 8324 8325 8326 8327 8329 8330 8331 8338 8339 8390 8499 8501 8502 8510 8511 8512 8513 8513 8514 8515 8519 8520 8527 8530 8531 8532 8560 8570

value displayed value displayed value displayed

Level

8100 8101 8102 8103 8104 8105 8106 8107 8108 8109 8110 8111 8112 8113 8114 8115 8116 8117 8118 8119 8120 8121 8122 8123 8124 8125 8126 8127 8128 8129 8130

Parameter 

Input EX21 module 1 Input EX21 module 2 Input EX21 module 3

Boiler pump Q1 Boiler pump speed Boiler temperature Boiler setpoint Boiler switching point Parameter Boiler return temp Boiler return temp setpoint Flue gas temp Flue gas temp max Primary exchanger temp Fan speed Set point fan Current fan control Burner modulation Water pressure Ionization current Hours run 1st stage Start counter 1st stage Hours run heating mode Hours run HW Current phase number Collector pump 1 Solar ctrl elem buffer Solar ctrl elem swi pool Collector temp 1 Collector temp 1 max Collector temp 1 min dt collector 1/exchanger 1 dt collector 1/HW dt collector 1/buffer dt collector 1/swimming pool Solar flow temp Solar return temp Total Solar Gain Hours run solar Hours run collect overtemp Hours run collector pump Solid fuel boiler temp Hours run solid fuel boiler

value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value reset value displayed value displayed value displayed value displayed value displayed value displayed value displayed value reset value reset value reset value reset value displayed value displayed value displayed value displayed value displayed value reset value reset value displayed value displayed value displayed value displayed value displayed value displayed value reset value reset value reset value reset value displayed value reset

8131 8138 8139 8140 8141 8150

Parameter  8304 8308 8310 8311 8312 8313 8314 8315 8316 8318 8321 8323 8324 8325 8326 8327 8329 8330 8331 8338 8339 8390 8499 8501 8502 8510 8511 8512 8513 8513 8514 8515 8519 8520 8527 8530 8531 8532 8560 8570

Parameter 

8700 8701 8702 8703 8704 8730 8731 8732 8740 8741 8743 8744 8749 8760 8761 8762 8770 8771 8773 8774 8779 8790 8791 8792 8800 8801 8804 8803 8809 8820 8830 8831 8832 8835 8836 8852 8853 8860 8875 8885 8895 8900 8901 8930 8931 8950 8951 8952 8962

3 3 3 3 3 3

Cascade flow temp Cascade flow temp setp Cascade return temp Cascade return temp setp Source seq ch'over current

state displayed value displayed value displayed value displayed value displayed value displayed

Level 3 3 2 2 3 3 2 2 2 3 2 2 3 3 2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 1 1 1 1 3 3

Boiler pump Q1 Boiler pump speed Boiler temperature Boiler setpoint Boiler switching point Parameter Boiler return temp Boiler return temp setpoint Flue gas temp Flue gas temp max Primary exchanger temp Fan speed Set point fan Current fan control Burner modulation Water pressure Ionization current Hours run 1st stage Start counter 1st stage Hours run heating mode Hours run HW Current phase number Collector pump 1 Solar ctrl elem buffer Solar ctrl elem swi pool Collector temp 1 Collector temp 1 max Collector temp 1 min dt collector 1/exchanger 1 dt collector 1/HW dt collector 1/buffer dt collector 1/swimming pool Solar flow temp Solar return temp Total Solar Gain Hours run solar Hours run collect overtemp Hours run collector pump Solid fuel boiler temp Hours run solid fuel boiler

Outside temp Outside temp min. Outside temp max. Outside temp attenuated Outside temp composite Central heating pump 1 Heat circ mix valve 1 open Heat circ mix valve 1 close Room temp 1 Room setpoint 1 Flow temp 1 Flow temp setpoint 1 Room thermostat 1 Central heating pump 2 Heat circ mix valve 2 open Heat circ mix valve 2 close Room temp 2 Room setpoint 2 Flow temp 2 Flow temp setpoint 2 Room thermostat 2 Central heating pump 3 Heat circ mix valve 3 open Heat circ mix valve 3 close Room temp 3 Room setpoint 3 Flow temp 3 Flow temp setpoint 3 Room thermostat 3 Hot water pump Hot water temp 1 Hot water temp setpoint Hot water temp 2 Hot water circulation temp HW charging temp Instant HW heater temp Instant HW heater setpoint Hot water flow Flow temp setp VK1 Flow temp setp VK2 Flow temp setp VK3 Swimming pool temp Swimming pool setpoint Primary controller temp Primary controller setpoint Common flow temp Common flow temp setpoint Common return temp Common output setpoint

Default Defau lt

DIAGNOSTICS CONSUMER CONSUMERS S

Default Defau lt

value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value reset value displayed value displayed value displayed value displayed value displayed value displayed value displayed value reset value reset value reset value reset value displayed value displayed value displayed value displayed value displayed value reset value reset value displayed value displayed value displayed value displayed value displayed value displayed value reset value reset value reset value reset value displayed value reset

Level

3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

DIAGNOSTICS HEAT GENERATION

value displayed value reset value reset value reset value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed

8700 8701 8702 8703 8704 8730 8731 8732 8740 8741 8743 8744 8749 8760 8761 8762 8770 8771 8773 8774 8779 8790 8791 8792 8800 8801 8804 8803 8809 8820 8830 8831 8832 8835 8836 8852 8853 8860 8875 8885 8895 8900 8901 8930 8931 8950 8951 8952 8962

3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

Outside temp Outside temp min. Outside temp max. Outside temp attenuated Outside temp composite Central heating pump 1 Heat circ mix valve 1 open Heat circ mix valve 1 close Room temp 1 Room setpoint 1 Flow temp 1 Flow temp setpoint 1 Room thermostat 1 Central heating pump 2 Heat circ mix valve 2 open Heat circ mix valve 2 close Room temp 2 Room setpoint 2 Flow temp 2 Flow temp setpoint 2 Room thermostat 2 Central heating pump 3 Heat circ mix valve 3 open Heat circ mix valve 3 close Room temp 3 Room setpoint 3 Flow temp 3 Flow temp setpoint 3 Room thermostat 3 Hot water pump Hot water temp 1 Hot water temp setpoint Hot water temp 2 Hot water circulation temp HW charging temp Instant HW heater temp Instant HW heater setpoint Hot water flow Flow temp setp VK1 Flow temp setp VK2 Flow temp setp VK3 Swimming pool temp Swimming pool setpoint Primary controller temp Primary controller setpoint Common flow temp Common flow temp setpoint Common return temp Common output setpoint

value displayed value reset value reset value reset value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed

8980 8981 8982 8983 9005 9006 9009 9031 9032 9033 9050 9051 9052 9053 9054 9055 9056 9057 9058

3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

Buffer temp 1 Buffer setpoint Buffer temp 2 Buffer temp 3 Water pressure H1 Water pressure H2 Water pressure H3 Relay output QX1 Relay output QX2 Relay output QX3 Relay output QX21 module 1 Relay output QX22 module 1 Relay output QX23 module 1 Relay output QX21 module 2 Relay output QX22 module 2 Relay output QX23 module 2 Relay output QX21 module 3 Relay output QX22 module 3 Relay output QX23 module 3

value displayed value reset value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed

Parameter 

Level

BURNER CONTROL

9500 9504 9512 9524 9529 9540

3 3 2 2 2 3

Prepurge time Required speed prepurging Required speed ignition Required speed LF Required speed HF Postpurge time

9650

3

Chimney drying

9651 9652

3 3

Req speed chimney drying Duration chimney drying

Fan running time of prepurge Prepurging fan speed Ignition fan speed Minimum power fan speed Maximum power fan speed Fan running time of postpurge Mode: Off Temporarily Permanently Fan speed during the function Operation time of function

Default Defau lt 1s Table1 Table1 Table1 Table1 5s Off 500rpm 10min

8980 8981 8982 8983 9005 9006 9009 9031 9032 9033 9050 9051 9052 9053 9054 9055 9056 9057 9058

Parameter 

3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

Buffer temp 1 Buffer setpoint Buffer temp 2 Buffer temp 3 Water pressure H1 Water pressure H2 Water pressure H3 Relay output QX1 Relay output QX2 Relay output QX3 Relay output QX21 module 1 Relay output QX22 module 1 Relay output QX23 module 1 Relay output QX21 module 2 Relay output QX22 module 2 Relay output QX23 module 2 Relay output QX21 module 3 Relay output QX22 module 3 Relay output QX23 module 3

Level

value displayed value reset value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed value displayed

BURNER CONTROL

9500 9504 9512 9524 9529 9540

3 3 2 2 2 3

Prepurge time Required speed prepurging Required speed ignition Required speed LF Required speed HF Postpurge time

9650

3

Chimney drying

9651 9652

3 3

Req speed chimney drying Duration chimney drying

Fan running time of prepurge Prepurging fan speed Ignition fan speed Minimum power fan speed Maximum power fan speed Fan running time of postpurge Mode: Off Temporarily Permanently Fan speed during the function Operation time of function

Default Defau lt 1s Table1 Table1 Table1 Table1 5s Off 500rpm 10min

3

ERROR LIST

Error

Internal Code

Description

28

Flue gas temp sensor

30 31

Flow sensor 1 Flow sensor cooling 1

Central heating enabled without any control (room thermostat, room unit o outside sensor) or outside sensor fault Short circuit Open circuit Solid fuel boiler sensor not found or in short circuit Common flow sensor not found or in short circuit Short circuit (lockout) Open circuit (lockout) Short circuit (temporary error) Open circuit (temporary error) Flow sensor mixing zone 1 not found or in short circuit Flow sensor cooling circuit not found or in short circuit

32

Flow sensor 2

Flow sensor mixing zone 2 not found or in short circuit

38

Flow sensor prim contr

40

Return sensor 1

46 47

Return sensor cascade Common return sensor HW sensor 1 (boiler with tank)

Flow sensor primary controller not found or in short circuit Short circuit Open circuit Return sensor cascade not found or in short circuit Common return sensor not found or in short circuit Short circuit Open circuit

10

Outside sensor

20

Boiler sensor 1

25 26

Boiler sensor solid fuel Common flow sensor

50

1 2

539 540 543 544

1 2

1 2

3

ERROR LIST

Error

Internal Code

Description

28

Flue gas temp sensor

30 31

Flow sensor 1 Flow sensor cooling 1

Central heating enabled without any control (room thermostat, room unit o outside sensor) or outside sensor fault Short circuit Open circuit Solid fuel boiler sensor not found or in short circuit Common flow sensor not found or in short circuit Short circuit (lockout) Open circuit (lockout) Short circuit (temporary error) Open circuit (temporary error) Flow sensor mixing zone 1 not found or in short circuit Flow sensor cooling circuit not found or in short circuit

32

Flow sensor 2

Flow sensor mixing zone 2 not found or in short circuit

38

Flow sensor prim contr

40

Return sensor 1

46 47

Return sensor cascade Common return sensor HW sensor 1 (boiler with tank) HW sensor 2 HW flow sensor HW circulation sensor Room sensor 1 Room sensor 2 Room sensor 3 Storage tank sensor 1 Storage tank sensor 2 Storage tank sensor 3 Collector sensor 1 Collector sensor 2

Flow sensor primary controller not found or in short circuit Short circuit Open circuit Return sensor cascade not found or in short circuit Common return sensor not found or in short circuit Short circuit Open circuit Solar DHW sensor not found or in short circuit DHW flow sensor not found or in short circuit DHW circulation sensor not found or in short circuit Room sensor circuit 1 not found or in short circuit Room sensor circuit 2 not found or in short circuit Room sensor circuit 3 not found or in short circuit Storage tank sensor 1 not found or in short circuit Storage tank sensor 2 not found or in short circuit Storage tank sensor 3 not found or in short circuit Solar collector sensor 1 not found or in short circuit Solar collector sensor 2 not found or in short circuit Short circuit (lockout) Short circuit (temporary error)  Automatic filling loop loop error (lockout) (lockout)  Automatic filling loop error (temporary (temporary error) LPB bus error More than 1 boiler using in the same address No comunication comunication / comunication error More than 1 room unit using in the same Central heating No radio comunication Internal counter out of range External modul 1 not found External modul 2 not found

10

Outside sensor

20

Boiler sensor 1

25 26

Boiler sensor solid fuel Common flow sensor

50 52 54 57 60 65 68 70 71 72 73 74 78

Water pressure sensor

81 82 83 84 85 91 98 99

LPB short-circuit/comm LPB address collision BSB short-circuit BSB address collision BSB Radio communication communicati on Data loss in EEPROM Extension module 1 Extension module 2

100

2 clock time masters

105

Maintenance message

109

Boiler temp supervision

1 2

539 540 543 544

1 2

1 2

506 560 793 797

499

Not correct configuration of clock time 503 504

Flatness 2 test on flow sensor Flatness 2 test on r eturn sensor

419 420 421

110

Lockout SLT

426 427 428 429 431 436 437 438

111

Shutdown limit thermost

117

Water pressure too high

118

Water pressure too low

119

Shutd water press swi

121 122

Flow temp CH1 Flow temp CH2

Maximum temperature of Electronic Safe Limit temperature Return temperature higher than flow temperature temperature more than 10K (temporary error) Return temperature egual or higher than flow temperature more than 10K-2 Temperature slope Unlock limit of temperature slope not reached Flow – return temperature higher than 56K (temporary error) Unlock limit of Flow – return temperature higher than 56K  Accepted times return temperature temperature higher than than flow temperature more than 10K reached (lockout error) Electronic Safe Limit temperature on return temperature  Accepted times Temperature Temperature slope slope reached  Accepted times Flow – return temperature temperature higher higher than 56K reached (lockout error) Maximum limit of flow temperature

565

Static water pressure limit (lockout error) > 2.8 bar

566

Static water pressure limit (temporary error) > 2.8 bar

125

Boiler temp too high

126

HW charg temp

Static pressure limit (lockout error) < 0.5 bar Water pressure limit (lockout error) Water pressure limit (temporary error) Flow temperature Central heating 1 not reached Flow temperature Central heating 2 not reached Reached limit of flow temperature of flow setpoint plus 30K for 2 times in 10 minutes No flow temperature variation for 20 seconds No return temperature variation for 20 seconds Maximum temperature of DHW charging not reached

127

Legionella temp

Legionella limit temperature temperatur e not reached

128

Loss of flame in op

Loss of flame during operation

130

Flue gas temp too high

Flue temperature limit reached

132

Safety shutdown

Lock on GP contact

133

Safety time exceeded

Loss of flame during ignition phase

563 564

500

151

BMU internal

152

Parameterization

501 502

325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 345 346

Software error Software error  Software error  Software error  Software error  Ingniter relay closing error Ingniter relay opening error Gas valve relay closing error Gas valve relay opening error Ingnition error of canal 2 Swithing off error of canal 2 Safety relay closing error Safety relay opening error Ingnition error of canal 1 Swithing off error of canal 1 Software error on micro 1 Gas type change error

347 348 349 350 572 573 574 575 576 577 578 579 580 581 153 160

Unit locked Fan speed threshold

164

Flow press switch CH

active 171  Alarm contact 1 active

active 172  Alarm contact 2 active active 173  Alarm contact 3 active active 174  Alarm contact 4 active

561 562 800 805 801 802 803 806 807 804 808 565 565

Max fan speed = Postpurge fan speed accepted Input HX parameterization: limit thermostat Input HX parameterization parameterization Input HX parameterization: air presure switch 10V signal input parameterization Input H6 with 2 different funtions associated Input H7 with 2 different funtions associated Input B4 with 2 different funtions associated Bypass pump Q12 parameterization Cooling request K28 parameterization parameterization Water filling K34 parameterization Hardware reset button pressed more than 10 seconds Fan speed threshold not reached Flow pressure switch Central heating (lockout error) Flow pressure switch Central heating (temporary error)  Alarm contact input input H1  Alarm contact input input H4  Alarm contact input input H2 of extension extension module module 1  Alarm contact input input H2 of extension extension module module 2  Alarm contact input input H2 of extension extension module module 3  Alarm contact input input H5  Alarm contact input input H6  Alarm contact input input H3  Alarm contact input input H7 Static water pressure limit (lockout error) Static water pressure limit (lockout error)

176 177

Water press 2 too high Water press 2 too low

178

Limit thermostat CH1

Limit thermostat Central heating 1 (mix zone)

179

Limit thermostat CH2

Limit thermostat Central heating 2 (mix zone)

195

Water refill time

196

Water refill time/week

241 242 243 260

Flow sensor yield Return sensor yield Swimming pool sensor Flow sensor 3

270

Exc temp diff h' exch

320

HW charging sensor

321

HW outlet sensor

322 323

Water press 3 too high Water press 3 too low

324

BX same sensors

325

BX/e'module same sens

326

BX/m'grp same sens

327

E'module same funct

791 795 792 796

507 1 2 565 565

Water refill time for sigle refilling elapsed (lockout error) Water refill time elapsed (temporary error) Water refill time weekly elapsed (lockout error) Water refill time weekly elapsed (temporary (temporary error) Flow sensor yield not found or in short circuit Return sensor yield not found or in short circuit Swimming sensor not found or in short circuit Flow sensor mixing zone 1 not found or in short circuit Temperature differential between flow temperature and exchanger exchanger temperature - Dry fire (lockout error) Charging DHW sensor not found or in short circuit Short circuit Open circuit Static water pressure limit (lockout error) Static water pressure limit (lockout error) More than one sensor with the same function associated More than one sensor (also on external module) with the same function associated More than one sensor (also on mixing zone) with the same function associated More than one sensor on external module with the same

328

Mix group same funct

329

E'mod/m'grp same funct

330 331 332 333 334 335 336 337

BX1 no function BX2 no function BX3 no function BX4 no function BX5 no function BX21 no function BX22 no function B1 no function

function associated More than one sensor on mixing zone with the same function associated More than one sensor (external module and mixing zone) with the same function associated No function associated to input BX1 No function associated to input BX2 No function associated to input BX3 No function associated to input BX4 No function associated to input BX5 No function associated to input BX21 No function associated to input BX22 No function associated to input B1

338

B12 no function

No function associated to input B12

339 340 343

Coll pump Q5 missing Coll pump Q16 missing Solar integration missing

Collector pump Q5 not found or not configurated configurat ed Collector pump Q16 not found or not configurated configurat ed Solar integrated not found or not configurated

344

Solar buffer K8 missing

Solar buffer not found or not configurated

345 346

Sol swi pool K18 missing Boiler pump Q10 missing

347

Solid fuel boil comp sens

348 349

Solid fuel boil addr err Buff valve Y15 missing

Swimming pool from solar not found or not configurated configurated Collector pump Q16 not found or not configurated configurat ed Solid fuel boiler comparative sensor not found or not configurated Solid fuel boiler address error Buffer valve not found or not configurated

350

Buffer address error

Buffer address error

351 353 371 372 373

Prim/sys pump addr err Casc sens B10 missing Flow temp CH3 Limit thermostat CH3 Extension module 3 359

System pump address error Cascade sensor not found or not configurated Flow temperature temperatur e Central heating 3 not reached Limit thermostat Central heating 3 (mix zone) External modul 3 not found Control value out of range

360

Calculated value over the threshold

361

Calculated value under the threshold

362

Gas valve stepper position over the threshold

363 364

Gas valve stepper position under the threshold Ionization current out of range

365

R value out of range

366 367 368 369 370 221 357

Open contact on stepper motor Short circuit on stepper motor Low supply voltage on stepper st epper motor High supply voltage on stepper motor Prevention of startup for a stepper motor is interrupted Fan speed out of range Fan speed out of range Ionization or fan speed with electrode drift test not in the defined area. Problem: Power supply, blower-PWM setting Too much corrrection of drift test Too much corrrection of drift test Drift test performed 4 times consecutive (temporary error) Control value limit reached during the test drift Ionization drift crash during testing

374

375

Sitherm Pro calculation

BV stepper motor

358 376

Drift test limit value

371 372 373 768 769

377 384 385 386

Drift test prevented Extraneous ligth Mains undervoltage Fan speed tolerance

429

Dyn water pres too high

430

Dyn water water pres too low low

431

Primary exch sensor (aluminium exchanger)

432

Function ground missing

433

Heat exch temp

418

558 559 557 1 2 547 548 746 747 508 509

Drift test counter c ounter monitor has excedded Flame present with gas valve closed Low supply voltage Fan speed out of range Dynamic water pressure too high (lockout error) Dynamic test times excedded (lockout error) Dynamic pressure test failed (lockout error) Short circuit (temporary error) Open circuit (temporary error) Short circuit (lockout error) Open circuit (lockout error) Feedback error from PCB (SR) Feedback erro from gas valve realy (BV1) Exchanger temperature > 95°C (lockout error) Exchanger temperature > 95°C (temporary error)

4

GAS ADA PTIVE SYSTEM

LUNA4 is provided with a brand new system GAC (Gas Adaptive Control): the electronic control together with the gas valve grant an automatic control of the combustion and ensure the following advantages during the installation as well as for the end user: • Reduction of the time for the installation, as any manual intervention has been deleted (adjustment or nozzles change); • The boiler is able to adapt to the quality of the gas and to the length of t he flue tubes maintaining a constant efficiency helping a reduction of the gas consumption and generating less pollution. The Gas Adaptive System maintains correct combustion by comparing the measured Flame Signal and the Reference Flame Signal. The Reference Signal follows a set curve depending on fan speed and it is part of the software. The system measures constantly the signal during the operation of the boiler and adjusts the gas flow rate in order to maintain the correct signal and the correct CO level. In this way is also considered the oxidation of the component (flame electrode and burner). The electronic gas valve has a modulator used to set the properly flame signal and so the correct air / gas ratio (LAMBDA). If the system is not able to assure the correct flame signal the boiler goes in lockout. The flame signal detected by the burner control is independent from: - value and type of supply voltage; - quality of the ground in the installation.

5

FAULT FAUL T FINDING 1 Initial Fault Finding Checks 1. Check that gas, water and electrical supplies are available at the boiler. NOTE: When instructed press and hold the ‘Reset’ for between 1-3 seconds to reset the boiler.

2. Electrical supply = 230V ~ 50 Hz. 4. The preferred minimum gas pressure is 10 mbar. 5. Carry out electrical system checks, i.e. Earth Continuity, Resistance to Earth, Short Circuit and Polarity with a suitable meter. NOTE: These checks must be repeated after any servicing or fault finding. 6. Ensure all external controls are calling for heat and check all external and internal fuses. Before any servicing or replacement of parts, ensure the gas and electrical supplies are isolated.

Table Of Error Codes

18.2 Error Codes 1. If a fault occurs on the boiler an error code may be shown by the facia display.

E20

Central Heating Flow NTC Fault

2. The codes are either a flashing two or three digit, number preceded by the symbol 'E '.

E28

Flue NTC Fault

E40

Central Heating Return NTC Fault

E50

Hot Water NTC Fault

E83

Communications error 

E109

Pre-Circulation Fault

E110

Safety Thermostat Operated

E111

Maximum flow temperature exceeded

E117

System Water Pressure Too High

E118

System Water Pressure Too Low

E125

Circulation Fault (Primary Circuit)

E128

Flame Failure

E130

Flue NTC Operated

E133

Interruption Of Gas Supply or Flame Failure

E151

PCB Fault

E160

Fan or Fan Wiring Fault

E384

False flame

E20, E28, E40, E50, E83, E151, E160 and E384 indicate possible faulty components. E110

and E111 shows overheat of the primary.

E117 is displayed when the primary water pressure is more than 2.7 bar. E118 is displayed when the primary water pressure is less than 0.5 bar. E133

indicates that the gas supply has been interrupted, ignition has failed or the flame has not been detected. E125 is displayed in either of two situations:i) If within 15 seconds of the burner lighting the boiler temperature has not changed by 1°. ii) If within 10 minutes of the burner lighting the boiler temperature twice exceeds the selected temperature by 30°. In these instances poor primary circulation is indicated. E128 is displayed if there has been a flame failure during normal burner operation.

3. By pressing the 'Reset' button for between 1-3 seconds when E 110, E125 & E133 are displayed it is possible to relight the boiler.

4. If this does not have any effect, or error codes are displayed regularly further investigation is required. .

.

Refer to Annex 1 “Illustrated Wiring Diagram” for position of terminals and components Central Heating - Follow operational sequence NO * Turn on mains power. Go to section ‘A’ If Error 83, 151 or 384 is flashing or re-occurs regularly The display illuminates check all PCB and communication connections, if this has no effe effect ct chan chan e PCB. PCB. YES * Error 110 flashing Error 111 flashing Error 133 flashing Error 125 flashing

YES

NO

Press the ‘Reset’ button for between 1-3 seconds

NO

If the E110 or E111 is still flashing. Go to section ‘H’

YES

Error 20, 28, 40 or 50 flashing

Go to section ‘D’

NO YES

Go to section ‘I’

Error 117 or 118 flashing NO

Ensure controls are set to demand and verify the contacts are closed

CH Rad. Symbol flashes

NO NO

Set the Central Heating temperature to Maximum. Pump runs.

YES

Ensure all controls and Programmers are calling for heat

Go to section ‘B’

YES

Fan runs after up to 3 minutes

NO

Error 160 flashing Go to section ‘C’

NO

Error 160 flashing Go to section ‘C’

YES

Fan runs at correct speed YES

Spark at ignition electrodes for up to 5 seconds and for 4 attempts. YES

NO

YES

Error 133 flashing

Go to section ‘F’ Press the ‘Reset’ button for between 1-3 seconds

Go to section ‘E’

NO

YES YES

Burner does not stay alight after 5 seconds

Burner lights

NO

Error 128 or Error 374 flashing. Go to section ‘N’

YES YES

YES

Error E125 flashing after 1 minute

Error E109 flashing

Error 133 flashing. Go to section ‘G’

Go to section ‘J’

NO YES

Error E110 or E111 flashing

Go to section ‘H’

NO NO

3 way valve open to central heating circuit

Go to section ‘K’

YES

Burner output modulates to maintain the temperature set YES

Burner goes out

Check the Central Heating NTC sensor Go to section ‘D’

YES

Go to section ‘M’

Error E130 flashing NO

NO

YES

YES

Fan stops after 10 seconds

Operation sequence successful

Fault Finding Solutions Sections

 A

Is there 230V at: NO

1.

Main terminals L and N

Check electrical supply

YES

NO

2.

Main terminal fuse

Replace fuse

YES

Display illuminated

NO

3.

B

PCB – X10 connector Mains terminals L & N

Connection OK at connector x40

Check wiring

Main or Display PCB fault

NO

Switch to DHW mode maximum flow rate and press reset. During the next three minutes is there:-

230V at PCB –connector x13 pump terminals Blue to Brown (See Wi ring Diagram)

YES

230V between PCB –connector x13 pump terminal Blue and PCB –connector x11 pump terminal Black. (See Wiring Diagram)

NO

Replace PCB

YES

YES

230V at Pump

NO NO

Replace Pump

Replace PCB

Check wiring

C

NO

1.

Fan connections correct at fan and PCB Connectors X11 & X23 See Wiring Diagram Diagram

Make connections

YES

YES

Is there 230V AC at fan terminals connector X11 blue to brown. See Wiring Diagram NO

Replace PCB

YES

Fan jammed of faulty winding

Replace fan

Temperature sensor faulty. Check correct location and wiring

D

YES

Cold resistance approximately 10kΩ @ 25° C (DHW and CH sensors) (resistance reduces with increase in temp.)

Gas at burner

E

NO

NO

Replace sensor

Ensure gas is on and purged

YES

Check wiring & PCB – X15 connector, is there 24 V DC across Gas valve terminals black to green. See Wiring Diagram.

Replace gas valve

NO

Replace PCB

F

NO

Check and correct if necessary 1. Ignition electrode and lead 2. Electrode connection 3. Spark gap and position

G

YES

Check wiring. Voltage at PCB – X15 connector is 24V DC across the igniter unit terminals Blue to Brown for 5 seconds during ignition phase . See Wiring Diagram

1.

Check the gas supply pressure: For Natural Gas greater than 10 - 11 mbar

2.

Check and correct if necessary 1.CO2 values - see instruction 2. Flame sensing electrode and lead connections 3. Flame sensing electrode position

YES

Replace PCB YES

Replace PCB

Flame current should be more than 1,7 μ A NO

Replace flame sensing electrode

Replace igniter unit

H

Overheat thermostat operated or faulty.

NO

Check for and correct any system faults. NO

 Allow to cool. Continuity across thermostat terminals more than 1.5 ohm

YES

Replace safety thermostat YES

NO

YES

Is E110 or E111 still flashing

Check Flow, Return, sensors. See section ‘D’

I

CH system pressure less than 0.5 bar or more than 2.7 bar. NO

J

Ensure that the system and boiler are fully vented.

YES

Restore System Pressure YES

Check wiring and pcb connection at connector x22 is there approx. 5 V DC between the green and black terminals

Replace pressure sensor  NO

Replace PCB

NO

System fault, correct.

Check flow temperature sensor connections and position. Cold resistance approximately. 10kΩ @ 25° C (CH sensors) (resistance reduces with increase in temp.)

YES

NO

YES

Go to section ‘B’

K

Is there 230V at:

1

PCB connector x13 3 way valve terminals Blue to Black central heating mode Blue to Brown domestic hot water mode See Wiring Diagram

NO

Replace PCB

YES

Check 3 way valve cable.

YES

2

Motor, 3 way valve

Replace motor 3 way valve

Replace sensor

Replace PCB

L

Is mains water filter and assembly clean and the rotor free to move.

YES

PCB connector x22 Hall effect sensor terminals. Check that the voltage is approximately 5 V DC between Red and Blue See Wiring Diagram

YES

Replace Hall Effect Sensor

NO NO

Clean or replace

Replace PCB

M 1.

Temperature sensors faulty. Cold resistance approximately 10kΩ @ 25° C (CH sensor) 20kΩ @ 25° C (Flue sensor) (resistance reduces with increase in temp.)

NO

Replace sensor

YES

2.

If pump is running the heat exchanger could be obstructed

Replace heat exchanger

N E128 flashing E374 flashing

Check if there is recirculation of flue gas in the sealed chamber 

YES

NO

1.

NO

2.

E376 flashing

YES

1.

Check and correct if necessary: 1. Selection of gas type 2. Flame sensing electrode position

Check supply pressure at the gas valve Check and correct if necessary: 1. Selection of gas type 2. Flame sensing electrode and lead connections 3. Flame sensing electrode position

Check wiring and PCB X25 connector (stepper motor gas valve) and X15 (EV gas valve)

Reset Drift Test results: -press both buttons for 6 seconds -enter at “specialist” level -go to Sitherm Pro menu -go to parameter 2749 -select yes

YES

NO

Replace PCB Replace flame sensing electrode

YES

Replace gas valve

NO

Replace PCB

WIRING DIAGRAM

6

BURNER BURNER PHASE (fault hist hi stor ory) y)

Phase 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

Description Permitted afterburn time Permitted time with air pressure switch closed or fan speed Permitted time with fan speed Standby Start prevention Maximum fan ramp-up time to prepurge speed Maximum fan ramp-up time to ignition speed Preventilation Maximum time to reach ignition speed after prepurging Maximum waiting time 1 Maximum waiting time 2 Preignition time 1st safety time (gas valve open) 2nd safety time (gas valve close) Interval (flame stabilization) Control mode Change to postpurging at last operating speed Change to postpurging at prepurge speed Postpurging at last operating speed Temporary error Lock-out error Postpurging at prepurge speed Chimney drying