1. MICS Kerys .......................................................................................................................................................................................... 2 1.1. Aim and structure .................................................................................................................................................................... 2 2. Using the interface ................................................................................................................................................................................ 2 2.1. Presentation of the keypad....................................................................................................................................................... 2 2.1.1 The display .............................................................................................................................................................................. 3 2.1.2 The alphanumeric keys............................................................................................................................................................ 3 2.1.3 The generating set operational keys ........................................................................................................................................ 4 2.1.4 The navigation keys ................................................................................................................................................................ 5 2.1.5 The signalling control keys ..................................................................................................................................................... 5 2.2. Interface ergonomics ............................................................................................................................................................... 5 2.2.1 Description of the screens ....................................................................................................................................................... 6 2.2.2 The home screen ..................................................................................................................................................................... 6 2.2.3 Navigation screens .................................................................................................................................................................. 7 2.2.4 Operating and configuration screens ....................................................................................................................................... 8 2.2.4.1. Upper band indicators ................................................................................................................................................ 8 2.2.4.2. Upper band commands............................................................................................................................................... 9 2.2.4.3. Lower band functions................................................................................................................................................. 9 2.2.5 The dialogue boxes.................................................................................................................................................................. 9 2.2.5.1. Confirming an entry in a main screen ........................................................................................................................ 9 2.2.5.2. Entering text ............................................................................................................................................................. 10 2.2.5.3. Entering numerical values ........................................................................................................................................ 10 2.2.5.4. Selecting from a list.................................................................................................................................................. 11 2.2.6 Saving modifications............................................................................................................................................................. 11 3. Using menus ....................................................................................................................................................................................... 12 3.1. Layout of the menus .............................................................................................................................................................. 12 3.1.1 Generating set operating modes ............................................................................................................................................ 13 3.1.2 Menu layout according to operating mode............................................................................................................................ 18 3.2. Operating menus.................................................................................................................................................................... 19 3.2.1 Driving .................................................................................................................................................................................. 19 3.2.2 Function keys ........................................................................................................................................................................ 19 3.2.3 Synchronisation column........................................................................................................................................................ 19 3.2.4 Power plant measurements summary .................................................................................................................................... 19 3.2.5 Measurements ....................................................................................................................................................................... 19 3.2.5.1. Generating set electrical measurements ................................................................................................................... 19 3.2.5.2. BUSBAR/grid(s) electrical measurements ............................................................................................................... 19 3.2.5.3. Mechanical measurements ....................................................................................................................................... 19 3.2.5.4. Generating set harmonic measurements ................................................................................................................... 19 3.2.5.5. BUSBAR/grid(S) harmonic measurements.............................................................................................................. 19 3.2.5.6. Rotating field measurements .................................................................................................................................... 19 3.2.5.7. Customised display of analogue values.................................................................................................................... 19 3.2.6 Alarms and faults .................................................................................................................................................................. 19 3.2.6.1. Help .......................................................................................................................................................................... 19 3.2.7 User settings .......................................................................................................................................................................... 19 3.2.7.1. Set points .................................................................................................................................................................. 19 3.2.7.2. Power thresholds ...................................................................................................................................................... 19 3.2.7.3. Wattmetric control / General parameters.................................................................................................................. 19 3.2.7.4. Wattmetric control / Thresholds............................................................................................................................... 19 3.2.7.5. Generating set priorities ........................................................................................................................................... 19 3.2.7.6. User parameters (1/2) ............................................................................................................................................... 19 3.2.7.7. User parameters (2/2) ............................................................................................................................................... 19 3.3. Regional parameters .............................................................................................................................................................. 19 4. Generating set starting modes ............................................................................................................................................................. 19 4.1. General information............................................................................................................................................................... 19 4.2. Prerequisites .......................................................................................................................................................................... 19 4.3. Manual starting...................................................................................................................................................................... 19 4.4. Starting using the no load test function ................................................................................................................................. 19 4.5. Starting using the load test function ...................................................................................................................................... 19 4.6. Starting in automatic mode.................................................................................................................................................... 19 5. Definitions .......................................................................................................................................................................................... 19 5.1. Glossary................................................................................................................................................................................. 19
1/62
33502015901_2_1
1. MICS Kerys 1.1. Aim and structure The MICS KERYS system comprises a range of electronic modules which are to be used for control and command operations, setting and protecting generating sets which stand alone or feature as part of a power plant. The system includes the following modules: ¾ industrial programmable automatic control module (A.P.I.) ¾ All or nothing logical inputs and outputs module ¾ Analogue inputs and outputs module ¾ temperature acquisition module ¾ electrical safety module ¾ Man-Machine Interface Module ¾ adjustment module An industrial programmable automatic control module and a Man-Machine Interface module form the basic configuration of the system.
2. Using the interface 2.1. Presentation of the keypad Generating set control keys
Alphanumeric keypad.
Signalling control keys
Navigation keys
Back-lit display with touch panel Man Machine Interface operation indicator LED (flashing)
2/62
33502015901_2_1
2.1.1 The display The display has the following specifications: ¾ 7-inch colour TFT display, 16/9, 65536 colours ¾ dimensions: 154 mm x 86 mm ¾ neon backlighting ¾ 480 x 234 resolution ¾ touch panel (8 columns x 8 rows)
2.1.2 The alphanumeric keys Pressing these keys successively allows the facial values to be entered. The characters entered appear in the order they were typed on the keypad.
3/62
33502015901_2_1
2.1.3 The generating set operational keys 1 2 3
4
8 9 10 11 12
13 14 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
7 6 5
Manual mode selection. The illuminated led indicates that the mode is active Selecting stop mode. The illuminated led indicates that the mode is active Automatic mode selection The illuminated led indicates that the mode is active Test in progress In automatic mode: test sequence control In manual mode: starting and stopping the motor Generating set circuit breaker opening control Open generating set circuit breaker Grid circuit breaker opening control Open grid circuit breaker Grid circuit breaker closing control Closed grid circuit breaker Grid voltage status Grid circuit breaker closing control Closed generating set circuit breaker Generating set voltage status
If test is requested a screen is brought up with the choice of a test under load or test off load.
4/62
33502015901_2_1
2.1.4 The navigation keys These keys are described in the section on "Interface Ergonomics".
2.1.5 The signalling control keys The
key is used to clear any faults
The
keys stops the buzzer
The
key controls the keypad indicator test.
2.2. Interface ergonomics The KERYS interface screen has a touch panel enabling various menus and commands to be accessed. The active zones on the screen are indicated by rectangles. The extended zones indicate the control keys, the recessed zones indicate the indicators. However, in some cases, the indicators allow access to menus listing general information; for example, pressing the fault indicator displays the list of alarms and faults. When an indicator is active, pressing one of these indicators displays the list of faults and alarms 15/10/02
19:10 :00
-1Electrical archives
GS 1
Event archives
-2Mechanical archives
Control key
Auto
Faults
Alarms
-3 – Event metering
Key selected.
These keys only need to be touched briefly. If they are pressed for too long and there is a key in the same position on the new screen, the corresponding command will be performed. Warning
5/62
33502015901_2_1
It is also possible to navigate through the menus using the keypad. Scroll up
Move up one level or quit if in dialogue box
Scroll left
Scroll right
Confirms the function of the selected key
Scroll down
Lastly, it is possible to access a menu directly by pressing the corresponding number key.
2.2.1 Description of the screens There are three types: ¾ the home screen ¾ the navigation screens ¾ the operation and configuration screens
2.2.2 The home screen This screen is the entry point to the system. It enables the main functions of the navigation to be accessed. 15/10/03
19:10 :00
GS 1
Home
Auto
Faults
-1Operation
-6System -2Fault finding -3Archiving/Metering
6/62
Alarms
-5Configuration -4Maintenance
33502015901_2_1
2.2.3 Navigation screens These screens enable the various sub-menus to be accessed. Upper level
15/10/03
19:10 :00
Active menu title
GS 1
Operation
Lower levels
Auto
Faults
Alarms
-0Welcome
-1Operation -2Function keys
-7User adjustments -6Alarms & Faults
-4Central measurements summary
-5Measurements
When a key is selected the lower level sub-menu appears if available or the allocated operation screen. A sub-menu can also be accessed by pressing the corresponding numbered key.
7/62
33502015901_2_1
2.2.4 Operating and configuration screens These screens bring up the information and commands relating to the active menu. They are divided into three zones: ¾ an upper band present on all types of screens ¾ the centre section in which the specific information relating to the selected menu appears ¾ a lower band Upper band
15/10/03
19:10 :00
GS 1
Centre section
Event archives
Auto
Faults
Alarms
-3 – Central measurements summary
-1Electrical archives
Lower band
2.2.4.1.
Upper band indicators System date System time Number of generating set with which the man machine interface is in dialogue with
Indication of alarm on the generating set concerned (flashing) Indication of fault on the generating set concerned (flashing) Indication of the operating mode of the generating set concerned
Name of the active screen 15/10/02
8/62
19:10 :00
GS 1
Welcome
Auto
Faults
Alarms
33502015901_2_1
2.2.4.2.
Upper band commands Access to the Alarms & Faults screen
Access to the regional parameters screen Access to the regional parameters screen
Access to the Alarms & Faults screen
Access to the operation screen
19:10:00
Welcome
15/10/03
If in power plant configuration, open a dialogue box enabling the generating set which you want to connect to be selected
2.2.4.3.
Auto
GS 1
Faults
Alarms
1st action: access to the home screen 2nd action: return to previously selected menu
Lower band functions Return to the navigation menu Pressing one or more of the short cut keys directs you to the functions linked to the active screen
Return to previous active operation screen
-3 – Central measurements summary
-1Function keys
2.2.5 The dialogue boxes To make it easier to enter information, there are special screens called "dialogue boxes" which appear if required.
2.2.5.1.
Confirming an entry in a main screen
When a value in the main menu has been modified the following dialogue box appears: Validation Validation of data entered Confirm
Esc.
The "Confirm" key saves the change, the "Esc." escape key cancels the change.
9/62
33502015901_2_1
2.2.5.2.
Entering text Name of the function modified
Text to be modified or created.
Inserts a space to the left of the cursor Title configuration CDE AERO Insert Confirm
Copy
Delete title
Paste
Delete a character
Esc.
Deletes the letter highlighted by the cursor Closes the menu without saving the modifications.
Deletes all the text
Saves the modifications and closes the dialogue box Left or right arrows on the keypad are used to move within the text. Characters are entered via alphanumeric keys on the keypad.
2.2.5.3.
Entering numerical values
The dialogue box heading displays the type of value entered,its unit of measurement and the variable concerned. These indications are linked to the type of modified parameter. When present, displays the minimum possible value When present, displays the maximum possible value
Thank you for interesting in our services. We are a non-profit group that run this website to share documents. We need your help to maintenance this website.