SC520.1 LSMR Procedures for SCFT

Share Embed Donate


Short Description

LTE Data...

Description

Ed.

00

Method of Procedure SC520.1 LSMR Procedures for SCFT

Date of Release:31-Oct-2014

Prepared By: Gaurav Gupta Reviewed By: Mr. Hiren Joshi

1|P a g e NEO eNB Part (R4G Project) © SAMSUNG Electronics Co., Ltd.

Change EARFCN Value/ Ed 00

COPYRIGHT This manual is proprietary to SAMSUNG Electronics Co., Ltd. and is protected by copyright. No information contained herein may be copied, translated, transcribed or duplicated for any commercial purposes or disclosed to the third partyin any form without the prior written consent of SAMSUNG Electronics Co., Ltd.

TRADEMARKS Product names mentioned in this manual may be trademarks and/or registered trademarks of their respective companies.

2|P a g e NEO eNB Part (R4G Project) © SAMSUNG Electronics Co., Ltd.

Change EARFCN Value/ Ed 00

Document History Edition

Date of Issue

Author

Remarks

00

31-Oct-2014

Gaurav Gupta

New Document

3|P a g e NEO eNB Part (R4G Project) © SAMSUNG Electronics Co., Ltd.

Troubleshooting flow

Table of Contents

Part – I (Pre-Checks During SCFT)

1.

Remote Electrical Tilt

2.

Physical Cell ID

3.

MIMO Configuration

4.

Track Area Code

5.

Alarm List

6.

RRH Lock / Unlock

7.

SON ANR

8.

EARFCN for UL & DL

Part-II (Checks During SCFT) 1.

OCNS Testing During SCFT

2.

eNB

3.

Smart Scheduler On/Off.

Internal Neighbour Relation Ship

© SAMSUNG Electronics Co., Ltd.

page 4 of 32

Change EARFCN Value/ Ed 00

Part – I (Pre-Checks During SCFT)

1.

Remote Electrical Tilt

2.

Physical Cell ID

3.

MIMO Configuration

4.

Track Area Code

5.

Alarm List

6.

RRH Lock / Unlock

7.

SON ANR

8.

EARFCN for UL & DL

5|P a g e NEO eNB Part (R4G Project) © SAMSUNG Electronics Co., Ltd.

Change EARFCN Value/ Ed 00

1)

Remote Electrical Tilt (RET)

1) How to check RET values: Write “RTRV-RET-INF” in command line and then click on “Execute” option. 2) Note: b)

a) No need to fill any values

appeared after selecting the command.

In Response Window :

Connect_Bord_ID represent L9CA card; 0 means first L9CA card just above the UAMA Card . Connect_Port_ID (0,1,2) represents the port sector on the Card

6|P a g e NEO eNB Part (R4G Project) © SAMSUNG Electronics Co., Ltd.

Change EARFCN Value/ Ed 00

b) How to Change RET Values: Write “CHG-RET-INF” in command line and values before Connect_BOA

= 0

click on “Execute” option. (for first L9CA Card)

Connect_POR=0/1/2 ALD_ID

=

0

ANT_ID=1 Remember:

Tilt = Value in degree * 10.

For Example: if value in degree=2, Then Tilt = 2*10 =20 RET Degree.

7|P a g e NEO eNB Part (R4G Project) © SAMSUNG Electronics Co., Ltd.

fill

following

Change EARFCN Value/ Ed 00

2) Physical Cell ID (PCI)

1) How to check PCI values: Write “RTRV-CELL-IDLE” in command line and then click on “Execute” option.

Note:

No need to fill any values

8|P a g e NEO eNB Part (R4G Project) © SAMSUNG Electronics Co., Ltd.

appeared after selecting the command.

Change EARFCN Value/ Ed 00

2) How to Change PCI Values: Write “CHG-CELL-IDLE” in command line and values before

Remember :

fill

following

click on “Execute” option.

A) SON ANR function should be off before executing the command. B) Sector should be locked before executing the command.

Cell_Num =0

andPHY_Cell_ID = Enter Required Value

and

then Click on “Execute”.

Cell_Num =1

andPHY_Cell_ID = Enter Required Value

and

then Click on “Execute”.

Cell_Num =2

andPHY_Cell_ID = Enter Required Value

and

then Click on “Execute”.

Note:Cell_Num = 0,1,2

represents

9|P a g e NEO eNB Part (R4G Project) © SAMSUNG Electronics Co., Ltd.

sector 1,2,3

Change EARFCN Value/ Ed 00

3) MIMO Configuration (Mode & Type)

1) How to check MIMO Configuration: Write “RTRV-DL-SCHED” in command line and then click on “Execute” option.

Note:

No need to fill any values

10 | P a g e NEO eNB Part (R4G Project) © SAMSUNG Electronics Co., Ltd.

appeared after selecting the command.

Change EARFCN Value/ Ed 00

2) How to Change MIMO Configuration: Write “CHG-DL-SCHED” in command line and following values before

fill

click on “Execute” option.

Cell_Num =0

and

DL_MIMO_MODE = TM3 or TM4

and

then Click on “Execute”.

Cell_Num =1

and

DL_MIMO_MODE = TM3 or TM4

and

then Click on “Execute”.

Cell_Num =2

and

DL_MIMO_MODE = TM3 or TM4

11 | P a g e NEO eNB Part (R4G Project) © SAMSUNG Electronics Co., Ltd.

and

then Click on “Execute”.

Change EARFCN Value/ Ed 00

4) Tracking Area Code (TAC)

ID

1) How to check TAC ID : Write “RTRV-DL-SCHED” in command line and then click on “Execute” option.

Note:

No need to fill any values

12 | P a g e NEO eNB Part (R4G Project) © SAMSUNG Electronics Co., Ltd.

appeared after selecting the command.

Change EARFCN Value/ Ed 00

2) How to Change TAC ID: Write “CHG-CELL-INF” in command line and before

fill

following values

click on “Execute” option.

Cell_NUM = 0/1/2 Cell_Size = Very Small,Large etc. Tracking_Area = Put required TAC Note:

In case if we are changing TAC the same should be changed in MME also.

13 | P a g e NEO eNB Part (R4G Project) © SAMSUNG Electronics Co., Ltd.

Change EARFCN Value/ Ed 00

5) Check Alarm List 1) How to check Alarm List : Write “RTRV-ALM-List” in command line and then click on “Execute” option.

Note:

No need to fill any values

14 | P a g e NEO eNB Part (R4G Project) © SAMSUNG Electronics Co., Ltd.

appeared after selecting the command.

Change EARFCN Value/ Ed 00

6) RRH

Lock/UnLock

Select eNB SAP ID as mentioned below and right click on mouse a table will open in which a option called “Administrative State” will appear . Click on Locked in order to off the RRH and Unlocked in order to On the RRH as mentioned below.

15 | P a g e NEO eNB Part (R4G Project) © SAMSUNG Electronics Co., Ltd.

Change EARFCN Value/ Ed 00

7) SON ANR 1) How to check SON ANR : Write “RTRV-SONFN-CELL” in command line and then click on “Execute” option. Note:

No need to fill any values

16 | P a g e NEO eNB Part (R4G Project) © SAMSUNG Electronics Co., Ltd.

appeared after selecting the command.

Change EARFCN Value/ Ed 00

2) How to Enable SON ANR : Write “CHG-SONFN-CELL” in command line and drfine following parametrs before

click on “Execute” option.

CELL_NUM = 0/1/2 ANR_ENABLE = Auto

17 | P a g e NEO eNB Part (R4G Project) © SAMSUNG Electronics Co., Ltd.

Change EARFCN Value/ Ed 00

8) EARFCN

1) How to check EARFCN for UL & DL : Write “RTRV-EUTRA-FA” in command line and then click on “Execute” option.

Note:

No need to fill any values

18 | P a g e NEO eNB Part (R4G Project) © SAMSUNG Electronics Co., Ltd.

appeared after selecting the command.

Change EARFCN Value/ Ed 00

2.1) How to Change EARFCN for UL & DL : Write following command “CHG-EUTRA-F A” in command line define following parameters before execute the command.

a) CELL_NUM = 0/1/2 b) FA_INDEX = 0 (always) c) EARFCN_UL & EARFCN_DL : put decided value Note: after execute 2.1 go to 2.2

19 | P a g e NEO eNB Part (R4G Project) © SAMSUNG Electronics Co., Ltd.

Change EARFCN Value/ Ed 00

2.1) How to Change EARFCN for UL & DL: Write following command “CHG-CELL-IDLE ” in command line define following parameters before execute the command. a) CELL_NUM = 0/1/2 b) EARFCN_DL = Put decided value c)

EARFCN_UL = Put decided value

20 | P a g e NEO eNB Part (R4G Project) © SAMSUNG Electronics Co., Ltd.

Change EARFCN Value/ Ed 00

Part-II (Checks During SCFT)

1.

Smart Scheduler On/Off.

2.

OCNS Testing During SCFT

3.

eNB Internal Neighbour Relationship

21 | P a g e NEO eNB Part (R4G Project) © SAMSUNG Electronics Co., Ltd.

Change EARFCN Value/ Ed 00

1) Smart Scheduler On/Off. How to OFF Smart Scheduler : a)

Write “CHG-SCHRSERV-INF” in command line and Select “Administrative = schrlocked” then click on “Execute” option

22 | P a g e NEO eNB Part (R4G Project) © SAMSUNG Electronics Co., Ltd.

Change EARFCN Value/ Ed 00

b)

Write “CHG-CELLSCHR-CONF” in command line and Select “CELL_NUM=0/1/2 ART_CELL=False” then click on “Execute” option.

23 | P a g e NEO eNB Part (R4G Project) © SAMSUNG Electronics Co., Ltd.

&SM

Change EARFCN Value/ Ed 00

2) How to On Smart Scheduler :

a)

Write “CHG-SCHRSERV-INF” in command line and Select “Administrative = schrunlocked” then click on “Execute” option

24 | P a g e NEO eNB Part (R4G Project) © SAMSUNG Electronics Co., Ltd.

Change EARFCN Value/ Ed 00

b)

Write “CHG-CELLSCHR-CONF” in command line and Select “CELL_NUM=0/1/2 SMART_CELL=True” then click on “Execute” option.

25 | P a g e NEO eNB Part (R4G Project) © SAMSUNG Electronics Co., Ltd.

&

Change EARFCN Value/ Ed 00

2) OCNS Testing

1) OCNS Loading : Write “Test-OCNS” in command line and define following parameters

a) SUB_CELL_NUM = 0/2/4 b) Modulation

= select decided value

c)

= select decided value

26 | P a g e NEO eNB Part (R4G Project) © SAMSUNG Electronics Co., Ltd.

Cell Load

Change EARFCN Value/ Ed 00

2) Terminating OCNS Testing :Write “Term-Test” in command line and define INVOCATION_ID mentioned below.

INVOCATION_ID = 0/1/2 + Execute

27 | P a g e NEO eNB Part (R4G Project) © SAMSUNG Electronics Co., Ltd.

Change EARFCN Value/ Ed 00

3) eNB Internal Neighbour Relationship

Step-1:

Select “Configuration”

28 | P a g e NEO eNB Part (R4G Project) © SAMSUNG Electronics Co., Ltd.

and then go to “Neighbour” option

Change EARFCN Value/ Ed 00

Step-2: b) c)

a)

Select Target eNB

Check Target eNB SAP ID is appear below “NeighbourRelation Info”. Go to “CELL_NUM” and select cell/Sector

29 | P a g e NEO eNB Part (R4G Project) © SAMSUNG Electronics Co., Ltd.

Change EARFCN Value/ Ed 00

Step-3: Let us consider we select sector-0 then we can see that the remaining sectors are appearing as aneighbour of sector-0 in “Target_Cell_Num”

30 | P a g e NEO eNB Part (R4G Project) © SAMSUNG Electronics Co., Ltd.

Change EARFCN Value/ Ed 00

31 | P a g e NEO eNB Part (R4G Project) © SAMSUNG Electronics Co., Ltd.

Change EARFCN Value/ Ed 00

32 | P a g e NEO eNB Part (R4G Project) © SAMSUNG Electronics Co., Ltd.

View more...