SAP2000-Example Moving Load
Short Description
book...
Description
Moving Load Analysis of Box Girder Using SAP2000
ACECOMS, AIT
SAP2000 Tutorial Example
Moving Load Analysis of Box Girder Using SAP2000 Table of Content Objective ...................................................................................................................................................... 3 Problem ........................................................................................................................................................ 3 Material .................................................................................................................................................... 3 Plan and Elevation View .......................................................................................................................... 3 Sections .................................................................................................................................................... 3 Step-by-Step Solution................................................................................................................................... 4 Start modeling by template....................................................................................................................... 4 Modify Structure ...................................................................................................................................... 5 Define Material Properties ....................................................................................................................... 8 Define Frame Section Properties.............................................................................................................. 9 Assign Frame Sections ........................................................................................................................... 11 Define Lanes and Vehicles ..................................................................................................................... 13 Define Moving Load Cases .................................................................................................................... 17 Set Analysis Options and Start Analysis ................................................................................................ 18 View Results........................................................................................................................................... 20
Moving Load Analysis of Box Girder
2/ 22
ACECOMS, AIT
SAP2000 Tutorial Example
Objective To demonstrate and practice step-by-step on the modeling, moving load analysis
Problem Plot influence line for vertical displacement at point A in Lane 1and plot moving load M33 moment for bridge as shown below for worst case of HS20-44 truck load and HS20-44L lane load applied to each lane simultaneously.
Material SteelEc = 5,000 ksi Poissons Ratio =
0.2
Lane 2 Centerline Frame Elements Centerline Lane 1 Centerline
20'
50'
6'
6'
Plan and Elevation View
100'
100'
100'
Sections Box Girder A = I = AShear =
35 500 12 ft2
ft2 ft4
40 400 30 ft2
ft2 ft4
Column A = I = AShear =
Moving Load Analysis of Box Girder
3/ 22
SAP2000 Tutorial Example
ACECOMS, AIT
Step-by-Step Solution Start modeling by template
Step 1-1: Start up screen of SAP2000, click on or go to File > New Model. Select working unit = “Kip, ft, F” and select “Portal Frame”.
Step 1-2: Enter “Portal Frame” parameters as shown in above figure and click OK.
Moving Load Analysis of Box Girder
4/ 22
SAP2000 Tutorial Example
ACECOMS, AIT
Step 1-3: Back to main screen, showing structure in “3D view” (left window) and “XZ Plane” view (right window). Close “3D view” window to enlarge “X-Z Plane” by clicking at top-right of “3D View” window.
Modify Structure
Step 2-1 (Display Joint & Frame Labels): Click on or go to View > Set Display Options, check the “Labels” box in “Joints” and “Frames/Cables” and click “OK”.
Moving Load Analysis of Box Girder
5/ 22
SAP2000 Tutorial Example
ACECOMS, AIT
Step 2-2 (Delete Columns at both ends):Select Frame 1 and 4 by clicking on them one by one and press “Delete” button in keyboard.
Step 2-3 (Assign Restraints): Select Joint 2 and 8. Click on or go to Assign > Joint > Restraints, click on Hinge support button and click “OK”.
Moving Load Analysis of Box Girder
6/ 22
SAP2000 Tutorial Example
ACECOMS, AIT
Step 2-4 (Move Joint 5): Click on Joint 5 and go to Edit > Move. Specify Delta Z = “20” (ft) and click “OK”.
Step 2-5 (Divide Frame 5, 6 and 7): Select Frame 5, 6 and 7 by drawing selection rectangular to cover all of them. Go to Edit > Divide Frame, enter Divide into “2” Frames and click “OK”.
Moving Load Analysis of Box Girder
7/ 22
SAP2000 Tutorial Example
ACECOMS, AIT
Define Material Properties
Step 3-1 (Change Working Unit): Select “Kip, in ,F” from drop-down menu at the bottom-right of screen.
Step 3-2 (Define Concrete Material): Click on or go to Define > Materials. Select “CONC” and click on “Modify/Show Material”, enter “5000” (ksi) and click “OK” 2 times.
Moving Load Analysis of Box Girder
8/ 22
SAP2000 Tutorial Example
ACECOMS, AIT
Define Frame Section Properties
Step 4-1(Change Working Unit): Select “Kip, ft ,F” from drop-down menu at the bottom-right of screen.
Step 4-2 (Define Column Section): Click on or go to Define > Frame/Cable Sections. Select “Add General” from second drop-down menu and click on “Add New Property”
Moving Load Analysis of Box Girder
9/ 22
SAP2000 Tutorial Example
ACECOMS, AIT
Step 4-3 (Define Column Section): Enter section property as shown above figure and click “OK”.
Step 4-4 (Define Column Section): Enter Section Name = “COLUMN”, select Material = “CONC” and click “OK”.
Moving Load Analysis of Box Girder
10/ 22
SAP2000 Tutorial Example
ACECOMS, AIT
Step 4-5 (Define Girder Section): Repeat Step 4-2 to Step 4-5 to define ”BOXGIRDER” section property.
Step 4-6: Back to “Frame Properties” dialog shows “BOXGIRDER” and “COLUMN” section have been added in the list and click “OK”.
Assign Frame Sections
Step 5-1 (Select Girders): Draw selection rectangular to cover frame 8 to 13. Selection Status at the bottom-left of screen shows “7 Points, 6 Lines Selected”.
Moving Load Analysis of Box Girder
11/ 22
SAP2000 Tutorial Example
ACECOMS, AIT
Step 5-2 (Assign Girder Sections): Click on or go to Assign > Frame/Cable > Sections, select “BOXGIRDER” and click “OK”.
Step 5-3 (Select Columns): Change back to undeformed mode by clicking on from Display > Show Undeformed Shape. Click on frame 2 and 3 one by one.
Moving Load Analysis of Box Girder
or
12/ 22
SAP2000 Tutorial Example
Step 5-4 (Assign Columns): Click on Sections, select “COLUMN” and click “OK”.
ACECOMS, AIT
or go to Assign > Frame/Cable >
Define Lanes and Vehicles
Step 6-1 (Define Lane 1): Click on or go to Define > Bridge Loads > Lanes and click “Add New Lane”. Enter Frame = “8”, Eccentricity = “-6” and click on “Add”. Repeat this step to define eccentricity = “-6” to frame 9 to 13 and click “OK”.
Moving Load Analysis of Box Girder
13/ 22
SAP2000 Tutorial Example
ACECOMS, AIT
Step 6-2 (Define Lane 2): Back to “Define Bridge Lanes” dialog and click “Add New Lane”. Enter Frame = “8”, Eccentricity = “6” and click on “Add”. Repeat this step to define eccentricity = “6” to frame 9 to 13 and click “OK” 2 times.
Step 6-3 (Select Vehicles): Click on or go to Define > Bridge Loads > Vehicles, select “Add Standard Vehicle” and click on “Add Vehicle”.
Step 6-4 (Select Vehicles): Select Vehicle Type = “HSn-44”, enter Scale Factor = “20” and click “OK”.
Moving Load Analysis of Box Girder
14/ 22
SAP2000 Tutorial Example
ACECOMS, AIT
Step 6-5 (Select Vehicles): Back to “Define Vehicles” dialog, click on “Add Vehicle”. Select Vehicle Type = “HSn-44L”, enter Scale Factor = “20” and click “OK” .
Step 6-6 (Select Vehicles): Back to “Define Vehicles” dialog shows 2 vehicle types have been added in list. Click on “OK” to finish this step.
Moving Load Analysis of Box Girder
15/ 22
SAP2000 Tutorial Example
ACECOMS, AIT
Step 6-7 (Define Vehicle Classes): Click on or go to Define > Bridge Loads > Vehicle Classes, select “Add new Class”. Select “HSn441”, enter Scale Factor = “1” and click “Add”. Select “HSn442”, enter Scale Factor = “1” and click “Add”. Click “OK” 2 times.
Step 6-8 (Define Bridge Response): Click on or go to Define > Bridge Loads > Bridge Responses, select all response results, select Method of Calculation = “Exact”. Click “OK”.
Moving Load Analysis of Box Girder
16/ 22
ACECOMS, AIT
SAP2000 Tutorial Example
Define Moving Load Cases
Step 7-1: Click on
or go to Define > Analysis Cases. Click on “Add New Case”.
Step 7-2: Specify parameters shown in above figure and click “OK”
Moving Load Analysis of Box Girder
17/ 22
SAP2000 Tutorial Example
ACECOMS, AIT
Set Analysis Options and Start Analysis
Step 8-1 (Set Analysis Options): Go to Analysis > Set Analysis Options. Select “XZ Plane” and click “OK”.
Step 8-2: Click on or go to Analysis > Run Analysis. Select “MODAL” case and click on “Run/Do Not Run Case” (not required in this example). Click on “Run Now”.
Moving Load Analysis of Box Girder
18/ 22
SAP2000 Tutorial Example
ACECOMS, AIT
Step 8-3: After analysis is complete, check error messages in analysis window. If no error report, click on “OK” to finish analysis step.
Step 8-4: Click on
to change back to undeformed mode.
Moving Load Analysis of Box Girder
19/ 22
SAP2000 Tutorial Example
ACECOMS, AIT
View Results
Step 9-1 (View Influence Line): Go to Display > Show Influence Lines > Joints. Specify “LANE1”, Joint ID = “10” (middle of bridge), Vector Type = “Displacement” and Component = “U3”. Click “Tables” to view in tabular form or click on “OK” to view influence line in diagram.
Moving Load Analysis of Box Girder
20/ 22
SAP2000 Tutorial Example
ACECOMS, AIT
Step 9-2 (View Moment 3-3 Diagram): Click on or go to Display > Show Forces/Stresses > Frames/Cables. Specify parameters as shown in above figure and click “OK”.
Step 9-3 (View Moment 3-3 Diagram): Click on or go to Display > Show Forces/Stresses > Frames/Cables. Specify parameters as shown in above figure and click “OK”.
Moving Load Analysis of Box Girder
21/ 22
SAP2000 Tutorial Example
ACECOMS, AIT
Step 9-4 (View Moment 3-3 Diagram): Force diagram in each frame can be displayed by right-mouse clicking. When move mouse over particular diagram, distance and force value will be displayed at the bottom of diagram.
Moving Load Analysis of Box Girder
22/ 22
View more...