Samsung
Smart Building Solution
Samsung Smart Building Solution 1
www.samsungtechwin.com
Introduction We are aiming for unsurpassed technology in the area of safety and energy solutions Samsung Techwin Techwin has leveraged outstanding technological competencies to emerge as a global leader in energy and safety solutions. We believe that creating new paradigms that are a step ahead of changing times is the only way to sustain growth and elevate customer value in today's fast-paced business environment. Samsung Techwin Techwin has played a pivotal role in the development of the precision machinery industry. industry. we are proactively addressing the dynamic marketplace, taking advantage of core competencies acquired to date to restructure our business model for greater profitability. Samsung Techwin is already a leader in security imaging, and now we are ready to make strides as a top-tier maker of precision control devices and systems. Our product lines will span next-generation "intelligent" robots for industrial, surveillance and medical applications as well as compressors and generators for ships, offshore structures and renewable energy production. Our commitment to excellence does not stop with technology development to ensure top quality. We continue to transform and work hard in order to earn the trust of our customers. To this end our corporate culture puts a priority on cultivating top-notch personnel, maintaining an open management policy and sharing benefits. We have taken on the creative challenge of applying cutting-edge technology to make life safer and more convenient. Our ultimate goal is your well-being and happiness, and we invite you to watch how we shape a better future for all.
Contents Smart Building Samsung Smart Building Solution Management Software
Smart Products
- Solution Overview & Features
- Software application
- System Architecture Architecture
- Smart Building Management
- Controllers - Sensors
BAS Products
S/W Functions 04
08
10
12
Make the
Building Smarter & Greener with Samsung Techwin
Samsung Smart Building Solution 3
Samsung
Smart Building Solution Samsung Smart Building Solution is an intelligent automated system designed for buildings, which creates a comfortable environment; utilizing integrated facility control, efficient building operation and improved energy efficiency.
Smart User Experience • Convenient building operation with friendly UX(User eXperience) • Compatible with standard web browsers • Access anytime, anywhere via a web-based remote building management system
Open structure for seamless customized integration • Advanced scalability with standard OS(Windows 2008 server, Windows XP, Windows 7) • Support for standard protocols such as BACnet, LonWorks, Modbus and oBIX(Open Building Information eXchange) • Seamless integration regardless of manufacturer
Vivid video surveillance with CCTV integration • Real-time remote monitoring available with CCTV • Support 4-channel live view to enhance your central management control • Auto video pop-up in case of events
Rapid response to events via remote control • Auto E-mail alert in case of events • Support for surveillance cameras to control remotely • Integration with mobile devices enables real-time video verification and energy analysis data monitoring
4 Samsung Smart Building Solution
Solution Overview & Features
Web-based remote building management system Support for standard protocols such as BACnet, LonWorks, Modbus and oBIX(Open Building Information eXchange) Enhanced convenience with friendly UX(User eXperience) Efficient building operation through energy saving Seamless integration regardless of manufacturer Remote video monitoring and auto video pop-up in case of events Auto e-mail alert in case of events Scalable communication with standard protocols among networks, controllers and sensors
Samsung Smart Building Solution 5
System architecture Samsung Smart
V ideo
RGB
Matrix
Access Control Server
TSM server
BEMS Server Total Management Server
CCTV Monitor
Ethernet TCP/IP,
HVAC
HVAC
Gateway
Power
Gateway
s k r o W n o L
Gateway
t e n C A B
s u b d o M
Meters
Lighting
Gateway s k r o W n Lighting Cont, o L
Lighting Cont,
Control
BACnet,
LonWorks,
Building Energy Management
Gateway s u b d o Power Meters M
GAS Meters
Meters
Sensors VAV
Sensor
VAV
Sensor
Lighting Cont, Flow Meters
Sensors Terminal Unit
Terminal Unit
Terminal Unit
Terminal Unit
Thermostats
Thermostats
Meters Program Switch
Sensors
HVAC Control System 6 Samsung Smart Building Solution
Power / Lighting Control System
Sensors
Building Energy Management System
Building Solution HVAC
Hot and Cold Water Control
Hot-water Supply Control Power Management
Matrix
V ideo / RGB Matrix
Boiler Control
Sunblind Control
Lighting Control
Security & Video Surveillance
Web Based Monitoring Service BUILDING NETWORK PROTOCOL
ODBC
Firewall
Firewall Modem
Internet Browser
Modem
Web Station
Internet
Mobile Device
Station
Modbus,
XML,
HTTP,
oBIX,
Sunblind
FOX
Access Control
IP CCTV
Gateway
NVR Speed Dome
s k r o W n o L
ACU
P I / P C T
P I / P C T
NVR
Motor Controller Fingerprint & RF
Fixed Dome
Box Cam RF Receiver
Monitor
Fingerprint Reader
5 8 4 / 2 2 4 / 2 3 2 S R
Fingerprint & RF
RF & Keypad
Zoom Cam Network Controller Remote Controller
Fingerprint Reader
Fingerprint Reader
Speed Dome RF/LF Reader
Roll Screen Video Server
Fixed Box RF/LF Card
Roll Screen System
Security System Samsung Smart Building Solution 7
Smart Building Management Software Software Application
HVAC management
HVAC facility monitoring and control for pleasant indoor environment
Power Monitoring
Status control of power supply, voltage in the electric room and switches
Lighting Control
Monitoring and control of lighting appliances status per floor
8 Samsung Smart Building Solution
Smart Building Management Software Function Smart HMI
Graphic User Interface A powerful graphic editor to create graphics for a variety of animations and 3D symbols makes your surveillance and control vivid on the screen.
Video surveillance screen In sync with the IP cameras installed in the facility room, display the event video in case of events and record the video with NVR within a specific time limit.
Point monitoring and control Collect data at a certain interval and in case of events, monitor data by floor and by facilities and search by settpoint name
History History data can be saved in various formats such as chart and report form. Real-time and time-phased history management let you check archive charts anytime. You can break down the charts into a group for comparing data at a glance.
System monitoring System Monitoring recognizes and displays the operation status of each controller on the network. You can check every single I/O operation status of connected controllers in detail.
Alarm List of recent 5 alarms is always xed at the bottom of the screen. It can also be hidden. In case of events, alarm video pop-up is generated for user’s immediate response. Past alarm videos can be output in the time frame upon request through history management.
Schedule You can make a daily, holiday or weekday schedule and edit your schedule with the simple click.
Samsung Smart Building Solution 9
Smart Products BACnet controllers for optimum building operation SMART Controllers for your building
• Adopt
BACnet protocol, the international standard protocol • Default and two types of extension modules for enhanced flexibility • Built-in energy-efficient control logic for optimal management system
SAG-B0640/B1280 Network gateway controller (64M/128M) • Control, monitoring, data logging, alarm, scheduling and network management and web service integrated • Remotely send data to the standard Web browser AX • System integration software Niagara technology adopted
SAC-B1612 BACnet Programmable Controller (28-point) Programmable controller for customized control of HVAC facilities including conditioner, refrigerator, boiler etc.
SAC-C1200I/C1212I I/O Extension Module for SAC-B1612 I/O Extension Module for SAC-B1612
SAC-B0608 BACnet Programmable Controller (14-point) Programmable controller for Rooftop Units, Fan coil Units, Chilled ceilings, Heat pumps, Unit ventilators and air conditioning units
SAC-B0507V BACnet VAV(Variable Air Volume) Controller • Controller for VAV Box control with its built-in actuator • Embedded air flow sensor, damper actuator and VAV application program
10
BAS Integrated building automation systems
Smart indoor sensor only for room SMART Sensors for your building
SAF-S0100/S0400 LCD Communicating Sensor (Temperature / Humidity) • Control room’s temperature, humidity level • System status indicator • Energy efficiency indicating with leaf icon for occupant's greener habit
SAF-S0500 Adjustable Thermostat Sensor • View the space temperature • Adjust the setpoint • Apply occupancy overrides • Built-in LAN port
Sunblind Controller SMART Sunblind controllers for your building
SAC-L0404S/L0408S Sunblind Controller • Integration with building system via standard protocol Lontalk • Sunblind control according to sunlight and room occupancy optimizes energy savings made as a result of HVAC parameters
Samsung Smart Building Solution 11
Samsung Smart Building Solution
BAS Products Software Mobile Application Network Control Unit HVAC Controller Sensor Sunblind Controller
SAS-B1000/B2000 Web-oriented multi-protocol building automation management software
Technical Specifications SAS-B1000
SAS-B2000
Device Supported device
Gateway
Max. Register device
3
Unlimited
Interconnection with X Energy management S/W
O ( option )
Function
History
Key Features SAS-B1000 •
for small enterprise system
Schedule
SAS-B2000 •
for large enterprise system
- Stable system operation : web-based remote building management system based on Niagara platform - Total management with just one S/W : HVAC, power, lighting, sunblind, CCTV - Easy-to-use: Manage everything within 3 clicks - Maximum user convenience: bookmark, point search - Compatibility: Open protocols supported (BACnet, oBIX, Modbus, Onvif) - Scalability : Configurable from small system to large system - Optimum customization : Intuitive UI and management - Multi-site monitoring and control - Seamless 3rd party system integration with various drivers - Alarm monitoring: video, message pop-up in case of alarms - Video surveillance: Compatible with standard protocol (Onvif) Real-time remote monitoring available with CCTV - System monitoring: Monitoring I/O operation status of controllers - Schedule: set operation schedule(daily, holiday, weekday) - Point control: search or bookmark certain facility for easier management
Video
Type Period Record count Chart builder Types of graph Type Order Function Supported format Supported Resolution Driver Object Registration Point Registration
Graph, Table Min 1 sec. Depends on SAG-Bxxx series Comparison of two more histories by graph Line, Area, Bar, Stacked bar, Discrete Line, Discrete Area, Pie Day/Week/Holiday/D-day Boolean, Numeric, Enumerate, String, Calender LiveView(up to 4 channel), PTZ/Preset Control, Video pop-up in case of events
MPEG-4 640 X 480
Onvif 1.2 supported Max 500 per screen 100 8 per group 500 Group Main pop-up Available Admin, Operator Authority User 50 User management Expiration Configurable per ID Off, normal, Fault Type Source state, Ack state, point, Alarm class, Priority, Normal time, Ack Filtering time, User, Alarm data, Last update Saving the generated alarm notes Memo Alarm Priority Setting the alarm class priority (Low, Normal, Emergency, High) Sending by class E-mail Video Video verification of camera linked to the point verification Graphic Monitoring
General OS
Windows XP professional, windows 7 32 bit, windows server 2008( IIS disabled)
System requirements (Recommended)
Main Functions
System requirements (Minimum)
CPU: Dual Core 2.0GHz, RAM: 2GB HDD: 500GB, Resolution: 1280x960 Web browser: Internet Explorer 7.0, 8.0, Network: 1 GB with RJ-45 connector
CPU: Intel Pentium IV, RAM: 1GB HDD: 100GB, Resolution: 1280x960 Web browser: Internet Explorer 7.0, 8.0, Network: 10/100MB with RJ-45 connector * Specifications are subject to change without notice.
Option S/W Video surveillance In sync with the IP cameras installed in the facility room, display the event video upon triggering an alarm and record the video with NVR within a specific time limit.
History History data can be saved in various formats such as chart and report form. Real-time and time-phased history management let you check archive charts anytime. You can break down the charts into a group for comparing data at a glance.
Point monitoring and control
Alarm Monitoring
Collect data at a certain interval and In case of alarm occurring, video pops in case of events, monitor data by up automatically. You can extract realfloor and by facilities and search by time or time-phased archives. settpoint name
System monitoring
Schedule
System Monitoring recognizes You c an make a dail y, ho liday or and displays the operation status weekday schedule and edit your of each controller on the network. schedule with the simple click. You ca n ch ec k ev er y si ng le I/O operation status of connected controllers in detail.
SAS-E1000
Station for Energy Management
SAS-E2000
Point for Energy Management
SAS-D1000
BACnet IP driver 500 points
SAS-D1100
Additional BACnet 500 points
SAS-D3000
Modbus TCP driver 500 points
SAS-D3100
Additional Modbus TCP 500 points
SAS-D4000
oBIX driver 500 points
SAS-D4100
Additional oBIX 500 points
SAS-D5000
MsSQL driver
SAS-D6000
ONVIF driver
13
Mobile Application Mobile multi-site building automation management software
Technical Specifications Function
History
Type
Graph, Table
Period
Min 1 sec.
Record count
Depends on SAG-Bxxx series
Chart builder
Comparison of two more histories by graph
Types of graph Line, bar Schedule
Video
Key Features - Remote building total management and system monitoring via mobile devices - Multiple building management with a single device - Convenient building operation with intuitive UI - Enhanced esthetic with elaborated graphical control - Real-time energy consumption monitoring: building management cost reduction - Auto alarm pop-up for immediate response - Integrated system control: HVAC, power, light, sunblind and energy management - Bookmark: quick link to frequently managed floors, equipments and important alarms - In case of alarms, real-time video verification enables rapid responses. - Compatibility: open protocols supported(oBIX)
Graphic Monitoring
User management
Alarm
Type
Day/Week/Holiday/D-day
Order
Boolean, Numeric, Calendar
Functio n
Vid eo pop-up in case of events, 1CH li ve view
Supported format
H.264, MJPEG
Supported resolution
640 X 480
Object
Max 500 per screen
Registration
100
Authority
Admin, Operator
User
50
Expiration
Configurable per ID
Type
Offnormal, Fault
Alarm verification Alarm history verification(Ack) Video verification Video verification of camera linked to the point
General OS
Android Honeycomb
Supported device
Galaxy Tab 10.1 * Specifications are subject to change without notice.
Key Functions
Equipment control
Schedule monitoring
Alarm list
Energy management
Video verification
Point control and monitoring of each equipment. Control categorized per floor and equipments and administrators.
Daily, holiday, regular day schedule. Controlled points output: Boonlean, Numeric
Occurred alarm monitoring per site’s point Alarm list per point , a larm descr iptio n monitoring
Energy management through comparison between current energy consumption and target energy consumption
Real-time video monitoring via IP camera installed in machine room. Auto video pop-up in case of alarm
System status Connection status of each devices
14
Configuration
History
Point search, control
User configuration(user ID, p/w), application settings etc.
History graph created per each control point. Multiple graphs comparison at once
Control point search and management. Categorization possible
SAG-B0640 / B1280 Network Control Unit (64M/128M)
Technical Specifications SAG-B0640
SAG-B1280
Operational IBM PowerPC 405 EP 250MHz 64MB DDR RAM 64MB Serial Flash
Processor Memory
IBM Power PC 440 524MHz 128MB DDR RAM 128MB Serial Flash
Network 2 Ethernet Ports - 10/100Mbps (RJ-45 connectors) 1 RS-232 Port (9-pin D- shell connector) 1 RS-485 non-isolated port (3 screw connector on base board) 1 One 20-Pin Euro-DIN Connector (for I/O and Power modules) 2 communication card option slots X 1
Methods
USB port
Operating Systems QNX RTOS, IBM J9 JVM Java Virtual Machine, Niagara AX
Type
Key Features
Mechanical
Control and management of external devices over the Internet
Material
Control, monitoring, data logging, alarm, scheduling and network management and web service integrated
Cooling
•
•
•
Remotely send data to the standard Web browser
•
Information integration from multi gateways via software
•
•
•
Chassis: plastic Cover: plastic
Dimensions (WxHxD) Weight
Internal air convention 160 X 122 X 62 mm (6.3''x 4.8''x 2.4'') (including connectors) 0.708Kg (1 lb 9 oz)
Environmental OperatingTemperature
Enhanced flexibility by adopting system integration software Niagara AX technology
Storage Temperature Humidity
0°C to 50°C (32°F ~122°F) 0°C to 60°C (32°F ~140°F) 5% ~ 95% RH
Stand-alone control, power management and integrated application
* Specifications are subject to change without notice.
OBIX client/server and Niagara Network (Fox) Niagara client/server drivers included
Recommended Peripherals Other Products (H/W)
Dimensions
SAG-M0200
SAG-P1000
Dual port RS-485 option card
24V AC/DC, 50/60Hz Power Supply Module. DIN rail mountable
Unit: mm (inch)
Other Products (S/W) 160(6.3'')
) ' ' 8 . 4 ( 2 2 1
SAG-D0200
Driver for MS/TP BACnet communications over RS-232 or RS-485 port
SAG-D0300
BACnet IP client license
SAG-D0400
Modbus driver license over serial
SAG-D0500
Modbus driver license over Ethernet
SAG-D0600
Extended memory part for 64Mb to 128Mb ( SAG-B0640)
SAG-D0700
Extended memory part for 128Mb to 256Mb ( SAG-B1280)
SAG-D0800
Web user interface engine license
SAG-D1000
Web programming tool license (SAG-D0800 required)
62(2.4'')
15
SAC-B1612 BACnet Programmable Controller (28-point) - 16 UI, 12 UO Technical Specifications SAC-B1612
Points
28-point controller
Universal inputs
16
SAF-S0100 inputs
12
Universal outputs
12
Max. extension module
2
Electrical Voltage
24VAC, ±15%, 50/60Hz, Class 2
Protection
3.0A user-replaceable fuse
Power Consumption
22 VA Typical + all output loads, max 65VA
Communication
Key Features •
•
•
•
•
•
•
Baud Rate
9,600/19,200/ 38,400/ 76,800 bps
Addressing
DIP switch(0-127)
Hardware
Programmable controller for customized control of HVAC facilities including conditioner, refrigerator, boiler etc. 16 UI, 12 UO(software configurable) Enhanced scalability with I/O extension module(up to 2) supporting up to 40 inputs and 36 outputs GUI-based HVAC control sequence programming tool provided
Processor
STM32(ARM Cortex™ M3) MCU, 32 bit
CPU speed
72 MHz
Memory
1 MB Non-volatile Flash (applications), 2 MB Non-volatile Flash (storage), 96 kB RAM
Status Indicator
Green LEDs : Power Status & LAN Tx Orange LEDs : Controller Status & LAN Rx
Environmental Operating Temperature
0°C to 50°C ; 32°F to 122°F
Support Niagara -based S-Controller Pro
Storage Temperature
-20°C to 50°C ; -4°F to 122°F
Built-in resistors and jumpers to control I/O eliminating the need for external resistor
Humidity
0 ~ 90% RH
Rugged hardware Inputs and Outputs minimizing the need for external protection components
Material
ABS
Color
Casing: Black / Connectors: Gray
Dimensions (W x H x D)
195.6mm x 119.4mm x 50.8mm (7.7” x 4.7” x 2.0”)
Weight
0.53kg (1.17lbs)
Installation
Direct din-rail mounting
AX
Mechanical
Inputs Universal, Software Configurable Voltage
- 0 to 10V DC (40k Ω input impedance) - 0 to 5V DC (high input impedance)
Current
0 to 20mA with 249Ω jumper configurable internal resistor
Digital
Dry Contact
Input Pulse types
Dimensions
Unit: mm (inch)
Resistor
Power supply output
195.60( 7.70˝ )
UI1 to UI4; 50Hz maximum; Min 10ms On/10ms Of - SO output compatible UI5 to UI16: 1Hz maximum; Min 500ms On/500ms Off - Dry contact 0 to 350 K Ω. All thermistor types that operate in this range are supported. The following temperature sensors are pre-configured: - Thermistor : 10K Ω Type 2, 3 (10K Ω @ 25°C; 77°F) - Platinum : Pt1000 (1K Ω @ 0°C; 32°F) - Nickel : RTD Ni1000 (1K Y @ 0°C; 32°F) RTD Ni1000 (1K Ω @ 21°C; 69.8°F) 15VDC; maximum 320mA (16 inputs x 20mA each)
Output
57.20 ( 2.25˝ ) 119.40 ( 4.70˝ )
158.70( 6.25˝ )
50.80( 2.00˝ )
Universal
0-10VDC linear, digital 0-12VDC (on/off), floating PWM, or 0-20mA (jumper configurable); software configurable. Built-in snubbing diode to protect against back EMF, for example when used with a 12VDC relay. - PWM control : adjustable period from 2 to 65 sec. - Floating control : requires two consecutive outputs · Min pulse on/off: 500msec. · Adjustable drive time period - HOA : Hand-Off-Auto switch (when equipped) · Hand position potentiometer range: 0-12.5VDC - 60mA max. @ 12VDC (60°C; 140°F)
Load resistance
Minimum 200Ω for 0-10VDC and 0-12VDC outputs Maximum 500Ω for 0-20mA output
Reset fuse
60mA @ 60°C; 140°F 100mA @ 20°C; 68°F * Specifications are subject to change without notice.
16
SAC-C1200I/C1212I I/O Extension Module for SAC-B1612
Technical Specifications SAC-C1200I
SAC-C1212I
Electrical Voltage Protection Power Consumption
SAC-C1200I
Max 50 VA
Communication Communication Bus Baud Rate Addressing
RS-485 38,400 bps DIP switch(0-127)
Hardware
SAC-C1212I
Key Features
Processor
STM32(ARM Cortex™ M3) MCU, 32 bit
CPU speed
64 MHz
Memory
64 KB Non-volatile Flash, 20 KB RAM Green LED : Power Status & LAN Tx Orange LED : Module Status & LAN Rx
Status Indicator
SAC-C1200I •
24VAC, ±15%, 50/60Hz, Class 2 3.0A user-replaceable fuse 22 VA Typical + all output loads Max 16VA
Environmental Operating Temperature Storage Temperature Humidity
12-point input extension module
SAC-C1212I
0°C to 50°C; 32°F to 122°F -20°C to 50°C; -4°F to 122°F Less than 90% RH
Mechanical
24-point I/O extension module
•
Material
ABS
Color
Casing: Black / Connectors: Gray
General Features
Dimensions (W x H x D)
195.6mm x 119.4mm x 50.8mm (7.7” x 4.7” x 2.0”)
Weight
0.53kg (1.17lbs)
I/O Extension Module for SAC-B1612
Inputs
12 UI, 12 UO(software configurable)
•
•
•
•
•
•
•
Programmable controller for customized control of HVAC facilities including conditioner, refrigerator, boiler etc. GUI-based HVAC control sequence programming tool provided
Voltage Current
Support Niagara AX -based S-Controller Pro Built-in resistors and jumpers to control I/O eliminating the need for external resistor Rugged hardware Inputs and Outputs minimizing the need for external protection components
Digital Input Pulse types
Resistor
Power supply output
Universal, Software Configurable - 0 to 10V DC (40k Ω input impedance) - 0 to 5V DC (high input impedance) 0 to 20mA with 249Ω jumper configurable internal resistor Dry Contact 1Hz maximum, 500ms On/500ms Off - Dry contact 0 to 350 K Ω. All thermistor types that operate in this range are supported. The following temperature sensors are pre-configured - Thermistor : 10K Ω Type 2, 3 (10K Ω @ 25°C; 77°F) - Platinum : Pt1000 (1K Ω @ 0°C; 32°F) - Nickel : RTD Ni1000 (1K Y @ 0°C; 32°F) RTD Ni1000 (1K Ω @ 21°C; 69.8°F) 15VDC; maximum 240mA (12 inputs x 20mA each)
Output
Dimensions
Universal
0-10VDC linear, digital 0-12VDC (on/off), floating PWM, or 0-20mA (jumper configurable); software configurable. Built-in snubbing diode to protect against back EMF, for example when used with a 12VDC relay. - PWM control : adjustable period from 2 to 65 sec. - Floating control : requires two consecutive outputs3 · Min pulse on/off: 500msec. · Adjustable drive time period - HOA : Hand-Off-Auto switch (when equipped) · Hand position potentiometer range: 0-12.5VDC - 60mA max. @ 12VDC (60°C; 140°F)
Load resistance
Minimum 200Ω for 0-10VDC and 0-12VDC outputs Maximum 500Ω for 0-20mA output
Reset fuse
60mA @ 60°C; 140°F 100mA @ 20°C; 68°F
Unit: mm (inch)
195.60( 7.70˝ )
57.20 ( 2.25˝ ) 119.40 ( 4.70˝ )
* Specifications are subject to change without notice. 158.70( 6.25˝ )
50.80( 2.00˝ )
17
SAC-B0608 BACnet Programmable Controller (14-point) - 6 UI, 8 UO Technical Specifications SAC-B0608
Electrical Voltage Protection Power Consumption
24VAC; ±15%; 50/60Hz; Class 2 2.0A user-replaceable fuse 14 VA Typical + all output loads, max 23VA
Communication EOL resistor Baud Rate Addressing
Built-in, jumper selectable 9,600/19,200/ 38,400/ 76,800 bps DIP switch
Hardware Processor CPU speed Memory
Key Features •
•
•
•
•
•
Status Indicator
Programmable controller for customized control of HVAC facilities including conditioner, refrigerator, boiler etc.
Environmental Operating Temperature
6 UI, 8 UO(software configurable)
Storage Temperature
GUI-based HVAC control sequence programming tool provided
Humidity
Support Niagara AX -based S-Controller Pro
STM32(ARM Cortex™ M3) MCU, 32 bit 68 MHz 384 KB Non-volatile Flash(applications), 1MB Non-volatile Flash (storage), 64KB RAM Green LEDs : Power Status & LAN Tx Orange LEDs : Controller Status & LAN Rx 0°C to 50°C; 32°F to 122°F -20°C to 50°C; -4°F to 122°F Less than 90% RH
Mechanical
Built-in resistors and jumpers to control I/O eliminating the need for external resistor Rugged hardware Inputs and Outputs minimizing the need for external protection components
ABS Casing: Black / Connectors: Gray Dimensions (W x H x D) 144.8 x 119.4 x 50.8 mm (5.7” x 4.7” x 2.0”) Weight 0.44kg (0.97lbs) Installation Direct din-rail mounting Material Color
Inputs Voltage Current Digital Input Pulse types
Resistor
Power supply output
Dimensions
Unit: mm (inch)
Output
Digital
144.78( 5.70˝ )
Universal, Software Configurable - 0 to 10V DC (40k Ω input impedance) - 0 to 5V DC (high input impedance) 0 to 20mA with 249Ω jumper configurable internal resistor Dry Contact Dry contact; 500ms minimum ON/OFF 0 to 350 K Ω. All thermistor types that operate in this range are supported. The following temperature sensors are pre-configured: - Thermistor : 10K Ω Type 2, 3 (10K Ω @ 25°C; 77°F) - Platinum : Pt1000 (1K Ω @ 0°C; 32°F) - Nickel : RTD Ni1000 (1K Y @ 0°C; 32°F) RTD Ni1000 (1K Ω @ 21°C; 69.8°F) 15VDC; maximum 120mA (6 inputs x 20mA each) 24VAC Triac, digital (on/off), floating, or PWM; software configurable · 0.5A continuous · 1.0A @ 15% duty cycle for a 10-minute period - PWM control: adjustable period from 2 to 65sec - Floating control: · Min pulse on/off: 500msec. · Adjustable drive time period External power supply 0-10VDC linear, digital 0-12VDC (on/off), floating or PWM; software configurable.
57.15 ( 2.25˝ )
119.38 ( 4.70˝ )
Universal
50.80 ( 2.00˝ ) 107.95( 4.25˝ )
Built-in snubbing diode to protect against back EMF, for example when used with a 12VDC relay. - PWM control: adjustable period from 2 to 65sec. - Floating control: · Min pulse on/off: 500msec. · Adjustable drive time period - 60mA max. @ 12VDC (60oC; 140oF) - Minimum resistance 200 - Auto-reset fuse · 60mA @ 60oC; 140oF · 100mA @ 20oC; 68oF * Specifications are subject to change without notice.
18
SAC-B0507V BACnet VAV(Variable Air Volume)
Technical Specifications SAC-B0507V
Electrical Voltage Protection Power Consumption
24VAC, ±15%, 50/60Hz, Class 2 2.0A user-replaceable fuse 3.0A user-replaceable fuse for triacs when using the internal power supply 14 VA typical plus all external loads 85 VA maximum
Communication Communication Bus EOL resistor Baud Rate Addressing
BACnet MS/TP Built-in, jumper selectable 9,600/19,200/ 38,400/ 76,800 bps Field configurable with any SAF-S0100 model
Hardware Processor CPU speed Memory
Key Features
Status Indicator
Controller only for VAV box control Meets the requirements of VAV zone applications, including: - Cooling only VAV boxes - Cooling with Reheat VAV boxes - Parallel Fan VAV boxes - Series Fan VAV boxes - Dual-Duct VAV system Accurate on-board air flow sensor for precise air flow monitoring and control at low and high air flow rates Built-in actuator with a brushless motor and integrated position feedback system Integrated VAV Performance Assessment Control Charts (VPACC) control sequences auto-detecting abnormal operation of VAV Covering all industry-standard VAV applications Rugged hardware Inputs and Outputs minimizing the need for external protection components
Operating Temperature Storage Temperature Humidity
•
•
•
•
•
•
•
Environmental
32.63 ( 1.28˝ )
Material ABS Casing: Black / Connectors: Gray Color Dimensions (W x H x D) 214.3 x 122.7 x 63.0 mm (8.4''x 4.8''x 2.5'' inches) 0.42kg (0.92lbs) Weight
Integrated Damper Actuator Motor Torque Rotation degree Fits Shaft Diameter
Voltage Current Digital Input Pulse types
Differential Pressure R an ge A cc ura cy Power supply output
181.7( 7.15˝ )
Belimo LMZS-H brushless DC motor 35 in-lb, 4 Nm 95˚ adjustable 5/16 ~ ¾", 8.5 ~ 18.2mm
Inputs
Unit: mm (inch)
0°C to 50°C; 32°F to 122°F -20°C to 50°C; -4°F to 122°F Less than 90% RH
Mechanical
Resistor
Dimensions
STM32(ARM Cortex™ M3) MCU, 32 bit 68 MHz 384 KB Non-volatile Flash, 1MB Non-volatile Flash, 64KB RAM Green LEDs : Power Status & LAN Tx Orange LEDs : Controller Status & LAN Rx
Universal, Software Configurable - 0 to 10V DC (40k Ω input impedance) - 0 to 5V DC (over 40k Ω input impedance) 0 to 20mA with 249Ω jumper configurable internal resistor Dry Contact Dry contact; 500ms minimum ON/OFF 0 to 350 K Ω. All thermistor types that operate in this range are supported. The following temperature sensors are pre-configured: - Thermistor : 10K Ω Type 2, 3(10KO @ 25°C; 77°F) - Platinum : Pt1000(1K Ω @ 0°C; 32°F) - Nickel : RTD Ni1000(1 K Y @ 0°C; 32°F) RTD Ni1000(1K Ω @ 21°C; 69.8°F) 0 ~ 500 Pa (0 ~ 2.0 in. W.C.) ±5.5% of reading over operating temperature range 15VDC, max 80mA (4 inputs x 20mA)
Output
) ˝ 3 8 . 4 ( 7 . 2 2 1
Digital
24VAC Triac, digital (on/off), floating, or PWM; software configurable · 0.5A continuous · 1.0A @ 15% duty cycle for a 10-minute period - PWM control: adjustable period from 2 to 65sec. - Floating control: · Min pulse on/off: 500msec. · Adjustable drive time period External power supply 0-10VDC linear, digital 0-12VDC (on/off), floating or PWM; so ftware configurable.
SAC-B0507V
Universal 19.05 ( 0.75˝ )
125.4( 4.94˝ )
15 ( 0.59˝ )
Built-in snubbing diode to protect against back EMF, for example when used with a 12VDC relay. - PWM control: adjustable period from 2 to 65sec. - Floating control: · Min pulse on/off: 500msec. · Adjustable drive time period - 60mA max. @ 12VDC (60°C; 140°F) - Minimum resistance 200Ω - Auto-reset fuse · 60mA @ 60°C; 140°F · 100mA @ 20°C; 68°F * Specifications are subject to change without notice.
19
SAF-S0100/S0400 LCD Communicating Sensor (Temperature / Humidity)
Technical Specifications SAF-S0100
SAF-S0400
Electrical Voltage
16V DC max, Class 2
Power Consumption
400mW typical
LCD Display Type
47 X 30 mm (1.85” X1.18” inches) with backlight
Symbols
Language-independent icons for mode and operating status
Temperature resolution
±0.1°C; ±0.1°F
Environmental Operating(Storage)
5°C ~ 40°C (-20~+50%)
Key Features
Humidity
0 ~ 95% RH
SAF-S0100
Mechanical
•
LCD communicating sensor to measure the room’s temperature level
SAF-S0400 •
LCD communicating sensor to measure the room’s temperature, humidity level
•
Encourage occupants to have greener habits with leaf icon while saving energy costs.
Material
ABS
Color
White
Dimensions (W x H x D) 83.55 x 117.27 x 26.83 mm (3.29” x 4.62” x 1.06” inches) Weight
0.18 kg (0.4 lbs)
Temperature Sensor
Low energy efficiency
Moderate energy efficiency
Higher energy efficiency
Highest energy efficiency
Simple and slim style sensors Control the room temperature to enhance occupants’ convenience Quick access to the network with the built-in LAN port Extended operation for non-business hours for maintaining comfort as well as saving power consumption Release/ set HVAC mode, set point and fan speed Show the system information including temperature, set point, occupancy and HVAC mode on the LCD display Reduce setup cost and enhance system maintenance using single CAT 5e cable
•
•
•
•
•
•
•
Dimensions
Unit: mm (inch)
Type
10K Ω NTC Thermistor
Range
5°C to 40°C; 41°F to 104°F
Accuracy
±0.5°C; ±0.9°F
Resolution
0.1°C; 0.18°F
Humidity Sensor Function
X
O
Communications Rate
38,400 bps
Communications
RS-485
Wiring
Cable length: 200m (650ft) maximum
Cable Type
T568B Cat 5e network cable, 4 twisted pairs
Connectors
IN : RJ-45 OUT: RJ-45 (pass-through for daisy chain connection) Network Access Jack: 3.5mm (1/8”) stereo plug connector
Daisy-chaining
Ranging from 4 to 12 SAF-S0100/SAF-S0400 sensors depending on the controller model - See the controller’s datasheet * Specifications are subject to change without notice.
83.55 ( 32.9˝ )
60.00 ( 2.36˝ )
) ˝ 2 6 . 4 ( 7 2 . 7 1 1
) ˝ 0 6 0 . 3 0 . 2 6 (
3.00typ ( 0.12˝ )
) ˝ 0 1 1 . 3 4 . 3 8 (
7.00 ( 0.28˝ )
26.83 ( 1.06˝ )
20
Mounting base plate shown detached
SAF-S0500 Adjustable Thermostat Sensor
Technical Specifications SAF-S0500
Environmental Operating Temperature
0°C to 50°C; 32°F to 122°F
Storage Temperature
-20°C to 70°C; -4°F to 158°F
Humidity
0 ~ 90% RH
Communication LAN Access Jack
Audio Jack, 1/8"(3.5mm)
Mechanical Material
ABS
Color
White
Dimensions (W x H x D)
117 x 84 x 40 mm (4.62" x 3.29" x 1.58”)
Weight
0.18kg (0.4lbs)
Control the room temperature inside to enhance occupants’ convenience
Installation
Wall mounting through mounting holes (see figure above for hole positions)
Extended operation for non-business hours for maintaining comfort as well as saving the power consumption
Output
Key Features •
•
•
Slim, compact style and clean lines well received by architects and building owners
•
Occupancy status with an LED indicator
•
Fan speed selector for improved personal comfort
•
•
•
Accurate temperature monitoring while some models have setpoint override for increased individual comfort Quick access to the network as soon as the controller gets started with the built-in LAN port Mounted on the wall or the electric cabinet with a separate sub-base
Types
10K Ω Type II Thermistor (10k Ω @ 25°C; 77°F)
Range
0°C to 50°C; 32°F to 122°F
Accuracy
±0.5°C, ±0.9°F
Functions Setpoint Adjustment
10k Ω linear rotary potentiometer
Occupancy override
Momentary push-button switch short-circuits the thermistor
LED
Green, powered by 12 VDC or 24 VAC
Fan speed Selection
5-position rotary-switch with factory-programmed resistance values
Auto
0Ω
Off
2,500 Ω
Fan speed 1
5,000 Ω
Fan Speed 2
7,500 Ω
Fan speed 3
10,000 Ω * Specifications are subject to change without notice.
Dimensions
Unit: mm (inch)
84( 3.29 )
60( 2.36 )
) 2 6 . 4 ( 7 1 1
) 6 3 . 2 ( 0 6
Ø25.4 ( 1.00 )
3.00typ ( 0.12 )
) 1 3 . 3 ( 4 8
7.00 ( 0.28 )
Mounting base plate shown detached
21
SAP-E1000/E1100/E2000/E2100 Enclosure for controllers
SAP-E1000
SAP-E2000
SAP-E1100
SAP-E2100
Technical Specifications
Key Features
SAP-E1000
SAP-E1000 •
SAP-E2000 •
X
Intercom
Compact Cabinet(SAP-E1100 including intercom)
Medium Cabinet(SAP-E2100 including intercom)
Material
Steel
Color
Silver
Dimensions (WxHxD) •
•
Preventing physical damage with curved edge Front-Acrylic cut-out for intercom setting
SAP -E1100
Weight
O
S AP-E2000
SAP-E2100
X
O
750 x 900 x 300 mm (29.5''x 35.4''x 11.8'')
800 x 1,500 x 300 mm(31.5''x 59''x 11.8'')
39 kg (86 lbs)
62 kg (137lbs) * Intercoms require additional order. * Specifications are subject to change without notice.
Unit: mm
Dimensions
800(11.8'') 300
750(29.5'') 750
'' 1500(59'')
900 900(35.4'')
SAP-E1000 / SAP-E1100
22
SAP-E2000 / SAP-E2100
SAC-L0404S/L0408S Sunblind Controllers (4CH/8CH)
Technical Specifications SAC-L0404S
SAC-L0408S
Electrical Voltage
230VAC 50/60Hz
Protection
Fuse or circuit breaker 16A
Hardware SAC-L0404S
Inputs
RJ-9 (Max 4)
Outputs
On/Off, 230 VAC / 5 A
EMC
EN61000-6-x, EN61000-4-x
Status Indicator
Power supply LED Outputs status LED Network status LED
Control Range
Max 4 blinds
SAC-L0408S
Key Features
Mechanical
Integration with building system via standard protocol Lontalk
Material
Sunblind control according to sunlight and room occupancy optimizes energy savings made as a result of HVAC parameters
Color
A comprehensive sunblind controller range: 4 or 8 sunblinds control, 230VAC
Mechanical Protectio n
IP 20
One controller to manage sunblinds in several rooms (depending on installation)
Dimensions (W x H x D)
290 x 154 x 50mm
Orders emitted by a remote control, presence and Lux level measure information given by multi-sensors
Box (W x H x D)
300 x 200 x 55 mm
Weights
1.2Kg
•
Modular solution : it can be adapted to an office repartitioning
Network
•
Installation on a double DIN rail or fixed onto the wall
Interface
•
Pluggable connectors: Easier connection in ceilings
Environmental
•
“ Pin service” : push button in front of the controllers
Operating Temperature
+5℃ ~ +45℃
Storage Temperature
-20℃ ~ +70℃
•
•
•
•
•
Max 8 blinds
Polycarbonate Plate
Black
Cover
Black
LonWorks® FTT-10A 78kbps, twisted pair
Humidity
+20% ~ +90% RH
Security
EN60669-2-1 * Specifications are subject to change without notice.
Dimensions
Unit: mm
290mm 275mm
m m m m 4 0 5 1 9
6.5mm
6 . 5 m m
23
Samsung Smart Building Solution
SAMSUNG TECHWIN CO., LTD. SAMSUNG TECHWIN R&D Center 701, Sampyeong-dong, Bundang-gu, Seongnam-si, Gyeonggi-do 463-400 , Korea TEL: 070-7147-8757/8528/8535 www.samsungtechwin.com S B 120
View more...
Comments