Sample ATP BTS 3900 Axis

November 11, 2017 | Author: Maulana Arif Rahman Hakim | Category: Electrical Connector, Electronic Engineering, Electrical Engineering, Electronics, Manufactured Goods
Share Embed Donate


Short Description

Download Sample ATP BTS 3900 Axis...

Description

ATP BTS 2G (BTS 3900 (Indoor/Outdoor) Doc. No. : AF-CL-0168-3-140209 Ver. 1.2 04-03-09

HUAWEI ATP BTS 2G (BTS 3900 (Indoor/Outdoor)

PT. HUAWEI TECH INVESTMENT APPROVED BY :

Name : Bruce Shelton Date :

PT. NATRINDO TELEPON SELULER APPROVED BY :

Name : Michael J. Bullough Date : 5th March 2009

PT. Huawei Tech. Investment All Rights Reserved. Doc. No: AF-CL-0168-3-140209 Ver. 1.2

ATP BTS 2G (BTS 3900 (Indoor/Outdoor) Doc. No. : AF-CL-0168-3-140209 Ver. 1.2 04-03-09

ATP BTS 2G BTS 3900 (Indoor / Outdoor)

SITE REGION

:

SITE ID

:

SITE NAME

:

SITE LOCATION

:

BTS TYPE

:

Huawei Technologies Co., Ltd. All Rights Reserved.

NTS

HUAWEI 2

Name : Date :

Name : Date :

ATP BTS 2G (BTS 3900 (Indoor/Outdoor) Doc. No. : AF-CL-0168-3-140209 Ver. 1.2 04-03-09

TABLE OF CONTENTS 1. Acceptance Testing 2. Acceptance Test Procedure 2.1

2.2

2.3

2.4

Installation Checklist 2.1.1

Indoor installation check list

2.1.2

Outdoor installation check list

Environment Monitoring Functional Test 2.2.1

Basic Shelter Alarms Monitoring Test

2.2.2

Function Test for Indoor BTS

2.2.3

Function Test for Outdoor BTS

BTS VSWR Test & Power transmitting 2.3.1

Feeder System VSWR test result

2.3.2

Power transmitting

BTS Commissioning Record 2.4.1

Call Tests

2.4.2

Handover Tests

2.4.3

24 Hours Stability Test

2.4.4

Alarm query test

2.5

Punch List Summary

2.6

Revision History

NTS

HUAWEI 3

Name :

Name :

Date :

Date :

ATP BTS 2G (BTS 3900 (Indoor/Outdoor) Doc. No. : AF-CL-0168-3-140209 Ver. 1.2 04-03-09

1. Acceptance Testing 1.1

NTS

Acceptance testing shall be carried out by the Contractor. The Contractor shall perform all tests required for commissioning and integration of the Equipment, Software and/or Services, as per the latest approved Schedule 3.

HUAWEI 4

Name :

Name :

Date :

Date :

ATP BTS 2G (BTS 3900 (Indoor/Outdoor) Doc. No. : AF-CL-0168-3-140209 Ver. 1.2 04-03-09

2.1. Installation Checklist 2.1.1. Indoor Installation Checklist SITE:

SITE CONFIG:

DATE:

Equipment overall condition Procedure

Pass

1

Visually inspect the cabinets for any damage.

2

Check that the cabinet doors and locks operate correctly.

Fail

N/A

Remark

Fail

N/A

Remark

Fail

N/A

Remark

Fail

N/A

Remark

Remarks Site Documentation Procedure 3 4

Pass

Check that the equipment is installed according to the as plan site design package. Check that the indoor cable ladder is installed according to the as plan side design package (applicable for Indoor Equipment)

Remarks Civil Works Check Procedure

Pass

5

Check that the cabinets have been securely fastened and are levelled correctly.

6

Check that indoor cable ladder above the cabinet has been installed correctly (applicable for Indoor Equipment).

7

Check that the DDF are grounded to the main grounding bus bar.

Remarks Equipment Specific Checks Procedure 8

Check that all equipment internal cables are correctly installed and labelled.

9

Check that the cabinet blanking panels have been installed.

NTS

Pass

HUAWEI 5

Name :

Name :

Date :

Date :

ATP BTS 2G (BTS 3900 (Indoor/Outdoor) Doc. No. : AF-CL-0168-3-140209 Ver. 1.2 04-03-09

Cabinet External Cabling Check Procedure 10

Check each the equipment rack is grounded to the main grounding bus bar and labelled.

11

Check that the Abis cables are connected to the correct position of DDF.

12

Check that the alarm cabling has been connected from the BTS to the DDF

13

Check that the support cabinet cables are correctly connected and labelled.

14

Check that the feeder jumper cables are tightened all the BTS.

15

Check that the support cabinet cabling has been cable tied to the cable ladder.

16

17

Pass

Fail

N/A

Remark

Pass

Fail

N/A

Remark

Check that the indoor feeder cable labelling is correct. Check that the DC power cable is the correct size and is terminated correctly.

18

Check the transmission cables, DC Cables and feeder jumpers are be correctly labelled

19

Check that support equipment is installed correctly.

Remarks Final Checks Procedure 20

Check that all installation and packing materials have been removed from the site.

Remarks

NTS

HUAWEI 6

Name :

Name :

Date :

Date :

ATP BTS 2G (BTS 3900 (Indoor/Outdoor) Doc. No. : AF-CL-0168-3-140209 Ver. 1.2 04-03-09

2.1.2. Outdoor Installation Checklist SITE:

SITE CONFIG:

DATE: Antennas

Procedure 21

Visually inspect the antennas and feeders for any installation damage.

22

Check that the correct type of antenna has been installed.

Pass

Fail

N/A

Remark

Fail

N/A

Remark

Fail

N/A

Remark

Remarks Feeders Procedure

Pass

23

Check that the bending radius of all feeders is greater than 20 x Ǿ and all feeder clamps are tightened

24

Check that outdoor feeder labelling is correct at the top and the bottom of the tower.

25

Check that the top feeder grounding is correctly terminated.

Remarks

Connectors Procedure 26

Check that all top feeder connectors are tight.

27

Check that all top feeders to jumper connections are tight.

28

Check that all top jumpers to antenna connections are tight.

Pass

Remarks

NTS

HUAWEI 7

Name :

Name :

Date :

Date :

ATP BTS 2G (BTS 3900 (Indoor/Outdoor) Doc. No. : AF-CL-0168-3-140209 Ver. 1.2 04-03-09

Weather sealing Procedure 29

Pass

Fail

N/A

Remark

Check all top grounding kits are weather-sealed correctly.

30

Check all feeders to jumper connections are weather-sealed correctly.

31

Check all jumpers to antenna connections are weather-sealed correctly.

Remarks Antenna Steelwork Procedure

Pass

32

Check that the antenna supporting steelwork is correctly installed.

33

Check all antenna mounting clamps and brackets have been tightened.

Fail

N/A

Remark

N/A

Remark

Remarks Antenna Installation Check Procedure 34

Check that the antennas are mounted at the correct height.

35

Check that the direction of all antennas in all sectors is correct.

Pass

Fail

Remarks

NTS

HUAWEI 8

Name :

Name :

Date :

Date :

ATP BTS 2G (BTS 3900 (Indoor/Outdoor) Doc. No. : AF-CL-0168-3-140209 Ver. 1.2 04-03-09

Antenna Installation Date

Sector

Sector 1

Antenna

DFRU11

Sector 2 RXD12

Height

M

Direction

Deg

Down tilt M/E

DFRU21 M

Deg

Sector 3

RXD22 M

M

Deg

/ Deg

DFRU31

Deg

/ Deg

RXD32

M Deg

M Deg

/ Deg

Remarks Outdoor Site Documentation Procedure

Pass

36

Check that the antenna layout is according to the site drawing.

37

Check that the feeder cable ladder is installed as per the site drawing.

38

Check that the feeder gland plate is installed as per the site drawing (applicable for Indoor Equipment)

Remarks SITE:

Fail

N/A

SITE CONFIG:

Remark

DATE: Civil Works Inspection

Procedure 39

40

Pass

Fail

N/A

Remark

Fail

N/A

Remark

Check that the feeder cable ladder is correctly installed Check that the feeder grand plate has been correctly installed (applicable for Indoor Equipment).

Remarks Feeder Grounding Procedure 41

Check number/location of feeder grounding kits.

42

Check all grounding is correctly terminated

NTS

Pass

HUAWEI 9

Name :

Name :

Date :

Date :

ATP BTS 2G (BTS 3900 (Indoor/Outdoor) Doc. No. : AF-CL-0168-3-140209 Ver. 1.2 04-03-09

43

Check all grounding kits are weather sealed correctly.

Remarks Concluding Checks Procedure 44

Pass

Fail

N/A

Remark

Check that all installation and packing materials have been removed from the site.

Remarks Notes: For the Swap BTS, this part “Outdoor Installation Checklist” is not be involved.

NTS

HUAWEI 10

Name :

Name :

Date :

Date :

ATP BTS 2G (BTS 3900 (Indoor/Outdoor) Doc. No. : AF-CL-0168-3-140209 Ver. 1.2 04-03-09

2.2 Environment Monitoring Functional Test 2.2.1 Basic Shelter Alarms Monitoring Functional Test for BTS 3900 SITE: NO

DATE: Basic Shelter alarm test( only for the indoor BTS)

1

Fire alarm

[BSC ID No 65384]

2

Door Open alarm

[BSC ID No 65385]

3

High temperature alarm

[BSC ID No 65386]

4

Spare

[BSC ID No 65387]

5

AC Removal alarm

[BSC ID No 65388]

6

Genset run

[BSC ID No 65389]

7

Genset failure

[BSC ID No 65390]

8

Genset low fuel

[BSC ID No 65391]

9

Phase R failure alarm

[BSC ID No 65392]

10

Phase S failure alarm

[BSC ID No 65393]

11

Phase T Failure alarm

[BSC ID No 65394]

12

Arrester Failure alarm

[BSC ID No 65395]

13

Rectifier Module alarm

[BSC ID No 65396]

14

Rectifier High voltage alarm

[BSC ID No 65397]

15

Rectifier Low voltage alarm

[BSC ID No 65398]

16

OBL Failure alarm

[BSC ID No 65399]

Pass

Fail

Remark

Audit

* Remark: Alarm test is tested end to end to verify correct operation from sensor to OMC message

NTS

HUAWEI 11

Name :

Name :

Date :

Date :

ATP BTS 2G (BTS 3900 (Indoor/Outdoor) Doc. No. : AF-CL-0168-3-140209 Ver. 1.2 04-03-09

2.2.2 Function Test for Indoor BTS SITE:

SITE CONFIG:

No.

Huawei

1

Procedure T01-0101

Power-On Test

2

T01-0201

Fan check

3

T01-0202

Board Indicators check

4

T01-0301

Transmission Test

5

T02-0101

Logging In to the Site Maintenance Terminal System

6

T02-0201

Board Software Loading

7

T02-0202

Board Software Activation

8

T02-0301

Site Reset Hierarchically

9

T02-0302

Cell Management State Changes

10

T02-0303

Cell Performance

11

T02-0401

BT Management State Change

12

T02-0402

BT Test

13

T02-0403

Viewing Channel State

14

T02-0501

RC Attribute Management

15

T02-0502

Changing RC Management State

16

T02-0601

Board Operation

17

T02-0602

Board Loopback Test

18

T02-0603

Board Alarm

19

T03-0101

Switching On an MS

20

T03-0102

Calls

21

T03-0103

Basic Data Services

22

T03-0104

SMS test

23

T04-0101

VSWR of the Antenna System

24

T04-0102

DTF Test

25

T04-0103

DFRU Transmit Power

NTS

Test Description

DATE: Pass

Fail

Remark

Audit

HUAWEI 12

Name :

Name :

Date :

Date :

ATP BTS 2G (BTS 3900 (Indoor/Outdoor) Doc. No. : AF-CL-0168-3-140209 Ver. 1.2 04-03-09

2.2.3 Function Test for Outdoor BTS SITE: No.

SITE CONFIG: Test Description

Huawei

DATE: Pass

Fail

Remark

Audit

Procedure 1

T01-0101

Power-On Test

2

T01-0102

Charging and Discharging of Storage Batteries

3

T01-0201

Board Indicators check

4

T01-0202

Running Status of the DPMU

4

T01-0301

Transmission Test

5

T02-0101

6

T02-0201

Logging In to the Site Maintenance Terminal System Board Software Loading

7

T02-0202

Board Software Activation

8

T02-0301

Site Reset Hierarchically

9

T02-0302

Cell Management State Changes

10

T02-0303

Cell Performance

11

T02-0401

BT Management State Change

12

T02-0402

BT Test

13

T02-0403

Viewing Channel State

14

T02-0501

RC Attribute Management

15

T02-0502

Changing RC Management State

16

T02-0601

Board Operation

17

T02-0602

Board Loopback Test

18

T02-0603

Board Alarm

19

T03-0101

Switching On an MS

20

T03-0102

Calls

21

T03-0103

Basic Data Services

22

T03-0104

SMS test

NTS

HUAWEI 13

Name :

Name :

Date :

Date :

ATP BTS 2G (BTS 3900 (Indoor/Outdoor) Doc. No. : AF-CL-0168-3-140209 Ver. 1.2 04-03-09

23

T03-0201

Door Status Alarm

24

T03-0202

Water Alarm

25

T03-0203

Smoke Alarm

26

T03-0204

Power Supply Failure

27

T04-0101

VSWR of the Antenna System

28

T04-0102

DTF Test

29

T04-0103

DFRU Transmit Power

NTS

HUAWEI 14

Name :

Name :

Date :

Date :

ATP BTS 2G (BTS 3900 (Indoor/Outdoor) Doc. No. : AF-CL-0168-3-140209 Ver. 1.2 04-03-09

2.3. BTS VSWR Test & Power transmitting power 2.3.1 Feeder system VSWR test result SITE:

SITE CONFIG:

D AT E :

V S W R a n d R et ur n L os s No.

Cell

Feeder VSWR

1

Cell 1

Feeder Length(m)

Distance To Fault (DTF)

Return Loss (dB)

Audit

RXD12 TRX11

2

Cell 2

RXD22 TRX 21

3

Cell 3

RXD32 TRX 31

Notes: 1. VSWR value shall be refer to the specification manual from the supplier 2. Setting at site master for cable 7/8" (vf and cable loss shall be refer to the specification manual from supplier) 3. Setting at site master for cable 1-5/8" (vf and cable loss shall be refer to the specification manual from supplier) 4. VSWR < 1.3 5. DTF test will be carried out according to the test procedure and test result included in the test documentation.

NTS

HUAWEI 15

Name :

Name :

Date :

Date :

ATP BTS 2G (BTS 3900 (Indoor/Outdoor) Doc. No. : AF-CL-0168-3-140209 Ver. 1.2 04-03-09

2.3.2 Power transmitting DRFU Transmitting Power Test as per T04-0103 DFRU ARFCN

No.

Power level (dBm) W

Cell 1

Cell 2

Cell 3

dBm

DRFU0 DRFU1 DRFU2 DRFU3 DRFU4 DRFU5

* BTS3900 is 40W TX power

2.4 BTS Commissioning Record 2.4.1. Call Tests DFRU

TS0

TS1

TS2

TS3

TS4

TS5

TS6

TS7

Audit

NO. CELL0

CELL1

CELL2

NTS

DFRU

0

DFRU

1

DFRU

2

DFRU

3

DFRU

4

DFRU

5

BCCH SDDCH

BCCH SDDCH

BCCH SDDCH

HUAWEI 16

Name :

Name :

Date :

Date :

ATP BTS 2G (BTS 3900 (Indoor/Outdoor) Doc. No. : AF-CL-0168-3-140209 Ver. 1.2 04-03-09

2.4.2

Handover Tests Call Test

Origin

Target

Cell

Cell

Target Cell BCCH

Pass

Fail

Remark

Audit

BSIC

CELL1 CELL2 CELL3 CELL2 CELL1 CELL3 CELL3 CELL1 CELL2

NTS

HUAWEI 17

Name :

Name :

Date :

Date :

ATP BTS 2G (BTS 3900 (Indoor/Outdoor) Doc. No. : AF-CL-0168-3-140209 Ver. 1.2 04-03-09

2.4.3 24 Hours Stability Test Site ID: The purpose of this test is to confirm that the BTS 2G is able to run for 24 hours without any faults.

RESULT:

Date:

Remark : Notes: The 24 hours is to be monitored from the TOC/NOC, and will be passed if BTS is in normal operation with no alarms.

2.4.4 Alarm query test 1. This test will be done from OMC (Region TOC) 2. The purpose of this test is to confirm that the BTS alarms are visible and there are no active alarms

RESULT:

Date:

Remark : Notes: if the site has no active alarms then write “OK, no active alarms”, otherwise record the alarm information in detail

NTS

HUAWEI 18

Name : Date :

Name : Date :

ATP BTS 2G (BTS 3900 (Indoor/Outdoor) Doc. No. : AF-CL-0168-3-140209 Ver. 1.2 04-03-09

2.5 Punch List Summary Site ID: Note: Record any items which do not pass the test, or cannot be tested, together with a detailed description..

No.

Test Ref. No.

SEVERITY (Minor / Major)

DESCRIPTION

1 2 3 4 5 6 7

NTS

HUAWEI 19

Name : Date :

Name : Date :

Rectified By HUAWEI NTS

Due Date

ATP BTS 2G (BTS 3900 (Indoor/Outdoor) Doc. No. : AF-CL-0168-3-140209 Ver. 1.2 04-03-09

2.6 Revision History

Version

Date

Revised by

1.1

14 Feb 2009

Michael J Bullough

1.2

4 Mar 2009

Michael J Bullough

NTS

Revisions Added Revision History table, typographical changes

Minor rewording, page 3

HUAWEI 20

Name : Date :