Rumus Dan Perhitungan Bising

August 24, 2022 | Author: Anonymous | Category: N/A
Share Embed Donate


Short Description

Download Rumus Dan Perhitungan Bising...

Description

 

I.  RUMUS DAN PERHITUNGAN 1.1  Rumus 1.1.1  E quiva ui vale lent nt C Co ontinuous N No oi se Lev Leve el (Leq) 1 Menit

Leq 1 menit  = 10 log 1⁄60 10,× ....10,×  × 5  Dimana : : Equivalen  Equivalentt Continuous Continuous Level  1  1 menit (dB(A)). : Nilai kebisingan 5 detik ke 1 –  12  12 (dB(A)). 1.1.2  E quiva ui vale lent nt C Co ontinuous N No oi se Lev Leve el (Leq) 10 Menit. Leq (1 menit) L1 –  L12

Leq 10 menit  = 10 log 1⁄10 10,×I....10,×X  × 1  Dimana : Leq (10 menit) : Equivalent Continuous Level 10 menit (dB(A)). LI –  LX : Hasil perhitungan Leq (1 menit) ke I –  X  X (dB(A)). 1.1.3  E quiva ui vale lent nt C Co ontinuous N No oi se Lev Leve el (Leq) pada L2

L2 = 10 log1 g 1⁄2 10,×  10,×  Dimana : Leq (1 menit) L1 –  L12

: Equivalent Continuous Level pada pukul 9.00-11.00 WIB (dB(A)). : Nilai kebisingan dari Leq (10 menit) dari pukul 9.00 dan 11.00 WIB (dB(A)). 1.1.4  E quiva ui vale lent nt C Co ontinuous N No oi se Lev Leve el (Leq) Selama Siang Hari (Ls).

Ls = 10 log 1⁄16 T1×10,× ....T4×10,×   Dimana : Ls L1 –  L4 T1 –  T4 16

: Equivalent Continuous Level selama siang hari (dB(A)). : Hasil perhitungan Leq (10 menit) ke 1 - 4 (dB(A)). : Durasi jam mewakili waktu ke 1 –  4  4 (jam). : Durasi selama 16 jam pada siang hari (jam). 1.1.5  E quiva ui vale lent nt C Co ontinuous N No oi se Lev Leve el (Leq) Selama Malam Hari (Lm).

Lm = 10 log1 g 1⁄8 T5×10,× .. ..  T7 × 10,×   Dimana : Lm L5 –  L7 T5 –  T7 8

: Equivalent Continuous Level selama malam hari (dB(A)). : Hasil perhitungan Leq (10 menit) ke 5 - 7 (dB(A)). : Durasi jam mewakili waktu ke 5 –  7  7 (jam). : Durasi selama 8 jam pada malam hari (jam). 1.1.6  E quiva ui vale lent nt C Co ontinuous N No oi se Lev Leve el (Leq) Selama 24 Jam (Lsm).

Ls Lsm m = 10 log log1/ 1/24 24 (16 (16 × 10,×  8 × 10 1 0,×+ ) 

 

Dimana : Lsm : Equivalent Continuous Level selama 24 jam (dB(A)). Ls : Hasil perhitungan Ls (dB(A)). Lm : Hasil perhitungan Lm (dB(A)). 24 : Durasi selama 24 jam pada siang-malam hari (jam). 1.2  Perhitungan Diketahui : Data Data Hasil Hasil Pengamatan pada Tabel 5.1 dan Tabel 5.2 (Kebisingan), (Kebisingan), serta Tabel 5.17 (Getaran) : Lsm dan Peak Value :

Ditanya Jawab ui vale lent nt C Co ontinuous N No oi se Lev Leve el (Leq) 1 menit 1.2.1  E quiva Pehitungan menit ke I pada jam ke 1 menggunakan Sound Level Meter  pukul   pukul 10.00 WIB

Leq 1 menit  = 10 log 1⁄60 10,× ....10,×  × 5  Leq 1 menit  = 10 log 1⁄60 10,×,  10,×,  10,×,  10,×,  10,×,  10,×,  10,×,  10,×,  10,×,  10,×,  10,×,  10,×,  × 5 = 67 67,6 ,6 dB A A  Pehitungan menit ke I pada jam ke 1 menggunakan Sound Level Meter pukul 11.00 WIB

Leq 1 menit  = 10 log 1⁄60 10,× ....10,×  × 5  Leq 1 menit  = 10 log 1⁄60 10,×,  10,×,  10,×,  10,×,  10,×,  10,×  10,×,  10,×,  10,×,  10,×,  10,×,  10,×,  × 5 = 66 66,3 ,3 dB A A  1.2.2  E quiva ui vale lent nt C Co ontinuous N No oi se Lev Leve el (Leq) 10 menit Perhitungan Leq 10 menit pada jam ke I menggunakan Sound Level Meter pukul

10.00 WIB

Leq 10 menit  = 10 log 1⁄10 10,×I ....10,×X  × 1  Leq Leq 110 men eniit = 10 log log 1⁄10 10,×,  10,×,  10,×,  10,×,  10,×,  10,×,  10,×,  10,×,  10,×,  10,×,  × 1 = 79 79,8 ,8 dB A A  Perhitungan Leq 10 menit pada jam ke I menggunakan Sound Level Meter pukul 11.00 WIB

Leq 10 menit  = 10 log 1⁄10 10,×I ....10,×X  × 1 

 

Leq Leq 110 men eniit = 10 log log 1⁄10 10,×,  10,×,  10,×,  10,×,  10,×,  10,×,  10,×,  10,×,  10,×,  10,×,  × 1 = 76 76,9 ,9 dB A A  ui vale lent nt C Co ontinuous N No oi se Lev Leve el (Leq) pada pukul 09.00-11.00 WIB (L2) 1.2.3  E quiva ,×, L2 = 10 log g11⁄2 10  10,×,   L2 = 78,59 dBA 

ui vale lent nt C Co ontinuous N No oi se Lev Leve el (Leq) selama siang hari (Ls) 1.2.4  E quiva ,× Ls = 10 log 1⁄16 T1×10 ....T4×10,×  

Ls siang  = 10 log 1⁄16 3 × 1 0,×  2 × 1 0,×,  6 × 1 0,× 71,98 98 dB dB A A   5 × 1 0,×  = 71, ui vale lent nt C Co ontinuous N No oi se Lev Leve el (Leq) selama malam hari (Lm) 1.2.5  E quiva

Lm = 10 log1⁄8 T5×10,× .. . . TT77 × 10,×   Lmmalam Lm malam = 10 log 1⁄8 2 × 1 0,×   3 × 10 1 0,×  3 × 10,× = 66,67 dB 

ui vale lent nt C Co ontinuous N No oi se L evel vel (Leq) selama 24 jam (Lsm) 1.2.6  E quiva

Lsm Lsm = 10 log log1/ 1/24 24 ((16 16 × 10,×  8 × 10,×+ ) 

Lsm Lsm = 10 log log1/ 1/24 24 ((16 16 × 10,×,  8 × 10,×,+ ) = 71, 1,88 88 dB A A  Tabel 6.1 Hasil Perhitungan Perhitungan Kebisingan Lingkungan

Tabel 6.1 Hasil Perhitungan Perhitungan Kebisingan Lingkungan

 

II.  Pembahasan Dalam praktikum kali ini yaitu pengukuran terhadap tingkat kebisingan dengan  bantuan alat yang bernama Sound Level Meter (SLM), pengukuran ini berlokasi di Plaza Kampus A Universitas Trisakti. Sebelum dilakukannya perhitungan tingkat kebisingan, alat yang digunakan yaitu Sound Level Meter  dikalibrasi  dikalibrasi terlebih dahulu pada 94 dB agar hasil pengukuran yag dilakukan akurat dan konsisten dengan instrumen lainnya, untuk nilai yang dicatat adalah nilai yang muncul tiap 5 detik selama 10 menit. Pengukuran kebisingan

ini dilakukan pada siang hari agar diperoleh data yang mewakili selang waktu tertentu dimana dalam praktikum ini mewakili selang waktu antara pukul 09.00-11.00 WIB (L2). Setelah penentuan tempat lokasi sampling, praktikan melakukan pengukuran secara insitu karena terdapat beberapa data meterologi yang hanya dapat diambil datanya pada saat dilokasi sampling. Parameter yang diukur secara insitu berupa kecepatan angin, suhu, kelembapan dan tekanan. Pengukuran parameter ini dilakukan secara bergiliran karena keterbatasan alat ukur yang disediakan. Suhu yang diperoleh 32 ˚C setelah dilakukan  pengukuran suhu, suhu, dilakukan pengukuran kecepatan angin yaitu, yaitu, 0,54 m/s, kelembapan 54% RH, tekanan 779 mmHg, dan arah angin yang berhembus dari arah selatan menuju utara. Kondisi lokasi sampling saat praktikan melakukan pengambilan sampel terdapat beberapa mahasiswa yang berlalu lalang sambil berbincang serta aktivitas para penjual penju al di plaza yang sedang membuat makanan dan minuman bagi para pembeli. Setelah dilakukan sampling selama 10 menit, kemudian dihitung nilai masing –  masing  masing Leq 1 menit diperoleh untuk menghitung Leq 10 menit. Untuk nilai Leq 10 menit pertama adalah sebesar 79,8 dB(A) , dan Leq 10 menit kedua adalah sebesar 76,9 dB(A). Setelah diperoleh data Leq 10 menit, dihitung kembali dengan memasukkan data –  data  data pendukung antara lain L1, L2, L3, L4, L5, L6, L7, dan Lm. Untuk perhitungan Ls diperoleh 71,98 dB(A), nilai Lm sebesar 66,78 dB(A). Yang kemudian nilai Ls dan Lm dijumlahkan maka didapatkan nilai untuk Lsm sebesar 71,88 dB(A). Menurut Keputusan Menteri Negara Lingkungan Hidup nomor 48 tahun 1996 tentang Baku Tingkat Kebisingan yang diperuntukan kawasan/lingkungan kegiatan sekolah atau sejenisnya adalah sebesar 55 dB(A), yang artinya nilai kebisingan yang berlokasi di d i plaza kampus A telah melebihi baku mutu yang seharusnya. Hal ini menandakan bahwa tingkat kebisingan di lokasi ini sudah tergolong tidak baik dan dapat menganggu kesehatan manusia dan kenyamanan lingkungan. III.  Kesimpulan Kesimpulan yang didapatkan dari percobaan dan perhitungan praktikum kebisingan lingkungan adalah sebagai berikut : 1.  Tingkat kebisingan Lsm di plaza Kampus A Universitas Trisakti yang  diperoleh dari hasil perhitungan L2 adalah sebesar 71,88 dB(A). 2.  Nilai kebisingan di siang hari (Ls) adalah sebesar 71,98 dB(A), pada malam hari (Lm) adalah 66,78 dB(A), dan Lsm sebesar 71,88 dB(A). 3.  Jika dibandingkan dengan nilai batas ambang baku mutu, maka nilai kebisingan di  plaza sudah melewati nilai batas ambang yang artinya dapat menyebabkan efek samping bagi kesehatan manusia yang memiliki kegiatan di sekitarnya.

 

LAMPIRAN

LOKASI SAMPLING

View more...