ELMO-F Vacuum Units with Vacuum Pumps, Range 2BE Selection example Application:

Vacuum Pumps

Compressors

100.000 m /h

30.000

10.000

10.000

Hybrid systems with roots fans

Hybrid gas-jet systems

Single-stage liquid-ring vacuum pumps 2BV or 2BE

Single-stage, double-action liquid-ring compressors 2BK, also combined with 2BE

Single-stage, single action liquid-ring vacuum pumps 2BV or 2BE

100

0,001

0,01

0,03

0,1

1,013

0,2 0,2

a Duty point: . V = 570 m3/h at 50 Hz p1 = 100 mbar

m /h 3

30.000

1000

e.g. foundry machines, casting technology

100.000 Multipump systems

3

2

3

10

Vacuum in bar

14

d Selection and order code: ELMO-F vacuum unit with vacuum pump 2BE1 153 - 0 No. 157 E r Type 2BE1 153-0BY4-Z F43+F44+F97 Motor 1LA5 183 - 4AA60 1) Note: When ordering motor, always indicate as separate item.

1000

Double-stage liquid-ring compressors 2BG, also combined with 2BE

7

5

s Choose the performance curve which lies closest to the duty point a. In this example, No. 157 E

100

ELMO systems as standard or customer-specific solutions covering a wide range of uses: from 1 mbar to 14 bar, from 10 to 100,000 m3/h

20

Pressure in bar

Selection and ordering examples for applications in the machine tools industry Selection diagram

Suction capacity V

3000

APV-5018e

m3/h 253E 2000

2) Motor should be ordered separately. For prices, other voltages etc., see Siemens price list M11. 3) Permissible voltage range: Degree of protection

Rated voltage acc. to DIN IEC 38

perm. Voltage range acc. to DIN VDE or DIN IEC 34-1

IP 55

400 V D / 690 V Y **

EEx e II T3

400 V D / 690 V Y **

380...420 V D / 660...725 V Y *** 400 V D / 690 V Y *

* Voltage tolerance here ±5% ** Voltage tolerance here ±10%

1500 252E

*** This voltage range is also shown on the rating plate, together with the currents occuring in this range. For this range, the permissible voltage tolerance acc. to DIN VDE 0530 or IEC 34-1 is ±5%

1000 203E

4) Based on operating duty “Standard” for inlet pressures: 2BE1: < 200 / W 200 mbar abs.

800 600 400

5) Measuring-surface sound-pressure level acc. to EN 21680-1, measured at 1 m distance in a free field, at medium inlet pressure and with inlet and discharge pipes connected. Tolerance: +3 dB.

202E 157E

300 30

1 2 Selection example

50

6) Special materials of construction, gaskets, motors and expanded scope of supply available on request.

Suction capacities from 20 to 500 m3 /h on request

80 100

200 300

500 mbar 1013

Inlet pressure (abs.) p 1

F

1) Scope of supply: 2BE1: vacuum pump with internal sealant supply, complete with mounted manifold, discharge-liquid separator, coupling, coupling guard and baseplate; without motor.

7) See accessories. 8) Including motor. For dimensions, see page 61.

The selection diagram corresponding to PNEUROP with a tolerance of ±10% for: • The evacuation of 100% saturated air with a temperature of 20 °C (68 °F). • Discharge pressure is 1013 mbar. • The operating liquid is water with a temperature of 15 °C (59 °F).

Selection and ordering information Curve No.

Motor Rated output

Vacuum pump Motor - Order No. 2)

Rated voltage 3)

Rated current

V

A

1LA5 183 - 4AA60 1MA6 186 - 4BC80 1LA5 207 - 6AA60 1MA6 207 - 6BC80 1LA5 223 - 6AA60 1MA6 253 - 6BC80 1LA6 283 - 8AB60 1MJ6 283 - 8CB60 1LA6 313 - 8AB60 1MJ6 313 - 8CB60

400 D / 690 Y 400 D / 690 Y 400 D / 690 Y 400 D / 690 Y 400 D / 690 Y 400 D / 690 Y 400 D / 690 Y 400 D / 690 Y 400 D / 690 Y 400 D / 690 Y

35 D / 20.2 Y 33.5 D / 19.3 Y 45.5 D / 26.3 Y 39 D / 22.5 Y 61 D / 35.3 Y 66 D / 38.2 Y 84 D / 48.5 Y 84 D / 48.5Y 138 D / 80 Y 138 D / 80 Y

kW d

157E 202E 203E 252E 253E

58

18.5 17.5 22 20 30 33 45 45 75 75

Operating fluid requirement 4)

Soundpressure level 5)

Degree of protection

Rated speed rpm

m3/h

dB(A)

IP 55 EEx e II T3 IP 55 EEx e II T3 IP 55 EEx e II T3 IP 55 EEx de II C IP 55 EEx de II C

1460 1470 975 980 980 985 730

1.9 / 1.3

70

2.1 / 1.4

71

2.6 / 1.7

71

4.4 / 2.9

73

740

5.2 / 3.5

73

Order No. 6) Vacuum pump

Accessories + mounting 7)

2BE1 153-0 B Y 4 - Z 2BE1 153-0 B Y 4 - Z 2BE1 202-0 B Y 4 - Z 2BE1 202-0 B Y 4 - Z 2BE1 203-0 B Y 4 - Z 2BE1 203-0 B Y 4 - Z 2BE1 252-0 B Y 4 - Z 2BE1 252-0 B Y 4 - Z 2BE1 253-0 B Y 4 - Z 2BE1 253-0 B Y 4 - Z

F43 + F44 + F97 F43 + F44 + F98 F43 + F44 + F97 F43 + F44 + F97 F43 + F44 + F96 F43 + F44 + F97 F43 + F44 + F97 F43 + F44 + F97 F43 + F44 + F97 F43 + F44 + F97

Total weight 8) kg 432 500 825 870 815 1000 1690 1710 2110 2150

elmo vacuum technology GmbH

236

266

288

elmo vacuum technology GmbH

14000 316

16000 346

9500 200

18000 390

10700 220

6800 132

All figures are for guidance only. For precise design, please ask for our catalogue sheets or contact your nearest office.

20500 500

12400 275

7400 160

Speed performance area of 2BE1 pumps

Speed of pump in rpm

210

8200 220

5000 110

22500 630

14000 315

330

Selection overviews for range 2BE1

9300 250

5600 132

3400 75

m3/h kW

15400 390

372

472

530

m3/h kW

5800 160

3600 80

2100 45

2BE1 403 - 0

2BE1 503 - 0

m3/h kW

4700 132

4400 110 8000 250

3200 65

1700 38

m3/h kW

1450 32

m3/h kW

4000 100

2400 54

1650 38 2650 65

1850 46

1000 23

2950 83

2050 58

1120 27

1240 33

840 22

440 10.8

m3/h kW

2BE1 153 - 0 760 18

340 8.1

m3/h kW

2BE1 152 - 0 660 16

290 7

1400 44.2

940 30

510 13.5

400 10.5

360 9

290 7

m3/h kW

2BE1 103 - 0 m3/h kW

200 4.9

m3/h kW

2BE1 102 - 0

1300

150 3.6

1100

m3/h kW

980

2BE1 101 - 0

920

2BE1 151 - 0

880

2BE1 303 - 0

820

2BE1 353 - 0

m3/h kW

840 20

m3/h kW

2BE1 203 - 0

790

580 13.5

740

m3/h kW

660

2BE1 202 - 0

590

2800 56

1150 26

565

m3/h kW

2BE1 603 - 0

11600 346

7200 200

4200 90

2BE1 703 - 0

m3/h kW

10500 275

6400 160

3700 75

2550 50

2BE1 253 - 0

2BE1 252 - 0

420

1450

600 16.5

460 12.4

400 11

330 8.2

235 5.8

175 4.3

1625

660 19.5

500 15

440 13

380 10

270 6.9

190 5

1810

710 24

540 18.1

480 16

2190

490 16

340 11.1

250 8.3

Selection Overviews for Range 2BE1

F

59

60

190

200

210

18500 270

14900 220

15200 250

13000 190

21000 335

12500 205

10700 160

23500 380

17800 280

9000 kW 130

m3/h

7400 kW 110

m3/h

230

2BE3 52. - 2

2BE3 50. - 2

All figures are for guidance only. For precise design, please ask for our catalogue sheets or contact your nearest office.

Speed performance area of 2BE3 pumps

Speed of pump in rpm

180

26400 470

20500 345

240

270

17200 295

14100 240

10500 170

8600 138

29400 550

22700 410

2BE3 42. - 2

2BE3 40. - 2

260

300

19100 340

15800 280 20900 395

17100 325

320

330

32500 640

24900 26400 27200 475 525 545

12100 210

10000 170

5600 kW 82

m3/h

4100 kW 63

m3/h

290

F

170

Selection overviews for range 2BE3

37000 805

13700 245

9200 205

6500 108

4800 80

340

30500 675

370

m3/h kW

15050 285

12300 287

380

m3/h 2BE3 72. - 2 kW

22800 426

18700 375

350

420

25500 575

21200 470

2BE3 60. - 2

8400 160

6150 113

3750 kW 62

18500 415

9200 180

6750 130

4100 70

490

2900 51

15100 338

470

m3/h

450

m3/h 2700 kW 45

440

m3/h 2BE3 62. - 2 kW

kW

m3/h

16600 335

13600 276

2BE3 32. - 2

2BE3 30. - 2

400

2BE3 67. -2

7500 130

5500 95

390

9950 210

7300 149

530

4700 85

3300 60

560

8400 185

610

10700 11400 230 270

7800 168

570

5200 100

3700 71

630

5600 116

4000 81

690

6000 126

4300 91

740

6500 151

4700 109

810

Selection Overviews for Range 2BE3

elmo vacuum technology GmbH

Dimensions for ELMO-F Units 2BE and Accessories Dimensions for 2BE1 15. to 2BE1 25. (mm) PV-5028

N2.2 N1.1 N4.0 N2.0

H3

H1

N1.0

H2

N3.0

B

L L1 2BE1 153 to 2BE1 253

2BE1 Type

Curve No.

For motor size:

B

H1

H2

H3

L

L1

Vacuum-/pressure-side pipe socket N1.0/N2.0 DN DIN 2501 PN 10

N1.1/N2.2 DN DIN 2501 PN 10

N3.0 Connection for op. liquid ISO 7/1

N4.0 Drain of separator ISO 7/1

2BE1 153

157 E 158 E

180M 180L

450

845

325

700

1265

1610

65

100

Rp ¼

Rp 2

2BE1 202

202 E 204 E 203 E 206 E

200L

660

1085

415

940

1625

1755

100

125

Rp 1

Rp 3

225M 250M

660

1110

415

965

1625

1935 2030

100

125

Rp 1

Rp 3

252 E 254 E 253 E 256 E

280M

630

1400

555

1185

1800

2255

125

150

Rp 1¼

Rp 3

315M

700

1400

555

1185

2060

2540

125

150

Rp 1¼

Rp 3

2BE1 203 2BE1 252 2BE1 253

Accessories 2BE For vacuum pump Type

Order No.

Weight kg

Compressed-air gauge, loose Chrome-nickel steel

0.8 - 4 m3/h

2BE1 15. to 2BE1 20.

2BX9 284 - 0HX02

8

for operating liquid

0.8 - 4 m3/h

2BE1 25.

2BX9 284 - 0HX03

14

2BE1

2BX9 012 - 1HD20

1

Pressure gauge -1 to +0.6 bar including shutoff tap and gaskets

Order codes Discharge-liquid separator

F43

Manifold

F44

Coupling, coupling protection, baseplate incl. motor mounting

F96, F97, F98

elmo vacuum technology GmbH

F

61

ELMO-F Systems

Standard closed-circuit units Key: M

010 030 080 130

030 010 PV-5054

N1.0

Connections: Vacuum pump Three-phase motor Separator Heat exchanger

280 N6.0

130

N1.0 N2.2 N3.3 N4.0 N4.1 N5.0 N6.0 N8.6

Gas inlet Gas outlet Make-up Overflow Total drain Cooling water inlet Cooling water outlet Measurement point

170

N5.0 260

N2.2

080

N4.0 N3.3 N8.6 N4.1

LG

ELMO-F closed-circuit vacuum pump range 2BW3 The ELMO-F Standard closed-circuit vacuum pumps/compressors 2BW consist of a vacuum pump/compressor with three-phase motor, liquid separator, heat exchanger, base frame and pipework. The schematic structure is shown in the picture above right.

With ELMO-F closed-circuit vacuum pumps/compressors 2BW, the condensate from the extracted process vapours is conveyed as the operating liquid in a closed circuit (vacuum pump/compressor ) separator ) heat exchanger ) vacuum pump/compressor). This prevents polluted waste water and avoids the need to use fresh water. Recovered condensate can be removed for further use. The cooling water is only heated up, not polluted.

Closed-circuit vacuum pump with roots backing pump

M 020 N1.1

(

M 010

N2.2 N4.0

163 080

N3.3

Key:

Connections:

010 Vacuum pump with motor 020 Roots backup pump 080 Separator, vertical 130 Heat exchanger 163 Non-return valve

N1.1 N2.2 N3.3 N3.4 N4.0 N4.1 N5.0 N6.0 N8.9

Gas inlet Gas outlet Make-up TI measurement nozzle Overflow Total drain Cooling water inlet Cooling water outlet Measurement point

N8.9 N4.1 130 N3.4

F

PV-5314b

N5.0 N6.0

ELMO-F closed-circuit vacuum pump with roots backing pump for inlet pressures to 10 mbar abs. Further versions: ELMO-F vacuum pumps with backing pumps like gas ejectors, steam ejectors, roots pumps (see figure above) and ELMO-G for low limit pressure from 1 to 100 mbar abs. ELMO-F plants with several parallel vacuum pumps and compressors for higher suction capacities.

62

To optimize the speed of ELMO-F closed-circuit vacuum pumps and compressors in accordance with the required process data, the following drives are possible:

For a flexible matching of ELMO-F closed-circuit vacuum pumps and compressors to the process data, the following control concepts can be supplied:

• Direct drive via coupling with electrical or other motors (e.g. Diesel motor) • Drive via belt drive with electrical or other motors (e.g. Diesel motor) • Drive via gear with electrical or other motors (e.g. Diesel motor)

• Bypass control, • Speed control with frequency converters when using electrical motors, • Process-bound complete control systems for plants

elmo vacuum technology GmbH

ELMO-F Systems

Vacuum system with roots backing pump and gas ejector

Series-connected ELMO-F compressors

Process

Gas ejector

Roots blower

Process

(

ELMO-F vacuum pump

Process

Process ELMO-F 2BE compressor

Separator

ELMO-F 2BG compressor

) Separator

Heat exchanger

Heat exchanger 1 mbar

1400 mbar

Sets for the range to 1 mbar.

Separator

800 mbar

Heat exchanger 14 bar

Series connection of ELMO-F compressors for use up to 14 bar abs.

When combined with reliable components such as roots pumps or gas ejectors, the area of use of ELMO-F compressors is considerably extended. Even mixed operation from vacuum to pressure presents no problems for the machines.

Examples of vacuum/compressor systems with ELMO-F pumps

Double unit 2BW4 203 - 0ZY99 - Z Suction flow: N2, Dichlorethane (EDC), VC, HCL Suction capacity: 105 Nm3/h Vacuum: 0.16 bar abs. Pressure: 1.7 bar abs. Drive capacity: 38 kW

F Power unit 2BW4 253 - 0BL4. - Z with gas ejector Condenser evacuation Suction flow: Vapour-air mixture Leakage air flow evaporation: 10.32 kg/h Vacuum: 0.015 bar abs. Drive capacity: 47 kW

elmo vacuum technology GmbH

63

Radial Blowers Range 2CF1 and 2CF2

Selection diagram 50 Hz Pa

40

4000

A PV-5020c

90dB(A)

30

20 16 12

Pressure difference

pf

mbar

3000

86

2000

75

1600

77

76

1200

10

1000

8

800

6

600

5

500

4

400

3

300

2

200

1

100 1

91

87

71

61

81

82 79

78

68

C

B

68 1,5

D

84

2

E

83

3

4

F

80

5

6

G

85

7 8 9 10 12

H

92 16

96 3

30 m /min 50 60

20

Capacity V 60

80 100

150

200

300

400 500

700

m3/h

1400 2000

1000

3600

Selection diagram 60 Hz mbar

Pa

40

4000

A PV-5104c

86dB(A)

pf

20 16 12

Pressure difference

30

3000

72

1600

77

77 1200

10

1000

8

800

6

600

5

500

4

400

3

300

2

200

1

100 1

83

64

84

91

87

63 79

79

70

C

The performance curves are valid for a medium with a density r = 1.2 kg/m³ (measured on the suction side).

86

77

2000

B

84

70 1,5

2

D

3

4

84 5

E

86 6

F

G

87

7 8 9 10 12

H

96

92 16

30 m3/min 50 60

20

Capacity V 60

80 100

150

200

300

400 500

700

1000

1400

2000

m3/h

3600

elmo vacuum technology GmbH

Radial Blowers Range 2CF1 and 2CF2 and Accessories Selection and ordering information Size

Designation letter

mm

Speed

rpm

Soundpressure level at 1 m distance 1) dB(A)

Other voltages

Tempe- Motor rature of Type conveying liquid 2) max.°C

Order No. Rated output kW

Rated voltage 3)

Rated current

V

Weight approx.

•AVAILABLE EX

kg

0.34 5) 0.36 5) 0.52 5) 0.69 5) 1.2 5) 2.6 5) 8.2 5)

•2CF1 052 - 0BA1 •2CF2 052 - 2EA 1 •2CF2 062 - 0EA 1 •2CF2 072 - 0EA 1 •2CF2 082 - 0EA 1 •2CF1 142 - 0EA 1 •2CF1 182 - 0EA 6

6.2 4.3 8.8 10.2 12.5 30 74

0.35 0.23 0.58 0.68 1.35 2.3 7.3

2CF1 052 - 0BA8 2CF2 052 - 2EA 8 •2CF2 062 - 0EA 1 2CF2 072 - 0EA 8 2CF2 082 - 0EA 8 2CF1 142 - 0EA 8 2CF1 182 - 0EA 8

6.2 4.3 8.8 10.2 12.5 30 74

0.85 0.80

•2CF1 052 - 1BH1

6.2 4.5

STOCK

A

Radial blowers with three-phase motor 50 Hz, IP 54 degree of protection 50 50 63 71 80 140 180

B C D E F G H

7350 4) 2850 2780 2750 2740 2900 2890

79 68 78 82 82 87 91

65 50 110 110 110 65 65

1LA5 053 1PP4 060 1LA5 060 1LA5 063 1LA5 070 1LA5 083 1LA5 113

0.12 0.06 0.18 0.25 0.42 1.17 4.2

230 d/ 400 * 230 d/ 400 * 230 d/ 400 * 230 d/ 400 * 230 d/ 400 * 230 d/ 400 * 400 d/ 690 *

Radial blowers with three-phase motor 60 Hz, IP 54 degree of protection 50 50 63 71 80 140 180

B C D E F G H

7350 4) 3300 3240 3300 3280 3480 3480

79 70 79 83 84 87 91

65 50 110 110 110 65 65

1LA5 053 1LA5 050 1LA5 060 1LA5 063 1LA5 073 1LA5 083 1LA5 113

0.14 0.09 0.24 0.29 0.63 1.27 4.2

460 * 460 * 460 * 460 * 460 * 460 * 460 *

Radial blowers with single-phase AC motor 50 Hz, IP 54 degree of protection 50 50

B C

7490 4) 2850

79 68

60 50

1LF5 053 1LF4 063

0.12 0.09

230 6) 230 6)

2CF2 052 - 2EH 1

Accessories for dischargeside

Weight approx.

Hose for inletside

Weight approx.

for dischargeside

Weight approx.

Metal filter for inletside

Weight approx.

Order No.

kg

Order No.

kg

Order No.

kg

Order No.

kg

Order No.

kg

2CF1 052 2CF2 052 2CF2 062 2CF2 072 2CF2 082

•2CX3 000

0.45

•2CX3000

0.45

1.5 1.2 1.2 1.3 1.4

•2CX3 004

1.5 0.7 1.1 1.2 1.2

•2CX3 730 •2CX3 731 •2CX3 732

For type

0.24 0.28 0.30

not necessary •2CX3 705 •2CX3 706 2CX3 726

Filter bag for dischargeside

Weight approx.

Guard screen for inletside

Order No.

kg

Order No.

0.19 0.22 0.24

2CX3 004

•2CX3 717 •2CX3 717 2CX3 720 2CX3 721

2CX3 722 2CX3 723 2CX3 724 2CX3 725

2CX3 003

2CX3 733

Weight approx.

Connecting elbow Weight approx.

Heating cartridge •AVAILABLE EX for dischargeWeight STOCK side approx.

kg

Order No.

Order No.

kg

kg

2CF1 052 2CF2 052

2CX3 002 2CX3 713

0.75 1.5

– –

– –

2CX3 001 –

1.8 –

2CX3 005 –

0.75 –

2CF2 062 2CF2 072 2CF2 082

2CX3 714 2CX3 715 2CX3 716

1.5 1.5 1.5

2CX3 735 2CX3 736 2CX3 737

0.22 0.25 0.27

– – –

– – –

– – –

– – –

Features The blower and motor form a single unit with the impeller mounted directly on the motor shaft. Only the types 2CF1 052-0BA. and 2CF1 052-1BH. have a gearbox between the impeller and the motor. Drive The blowers have surface-cooled, three-phase or single-phase motors with IP 55 class of protection. They are suitable for continuous operation.

elmo vacuum technology GmbH

Voltage code number

500 V *, 50 Hz

3

Required voltage and frequency: C

9

C Please indicate in plain text and add L1 Y. 1) The tabulated values are with medium throttling. 2) Max. ambient temperature 40 °C. 3) Permissible voltage range. Rated voltage acc. to DIN IEC 38*

Permissible voltage range acc. to DIN VDE 0530 or DIN IEC 34-1**

Frequency Hz

230 V D / 400 V Y 220...240 V D / 380...420 V Y 50 400 V D / 690 V Y 380...420 V D / 660...725 V Y 50 460 V Y 460 V D

440...480 V Y 440...480 V D

60 60

* Voltage tolerance here ±10%. ** This voltage range is also shown on the rating plate, together with the currents occuring in this range. For this range, the permissble voltage tolerance acc. to DIN VDE 0530 or DIN IEC 34-1 is ±5%. 5) At 400 V, 50 Hz.

Duct connector for inletWeight side approx.

not necessary 2CX3 726 2CX3 727 •2CX3 728

Voltage, frequency

4) 2-pole motor with gearbox.

Selection and ordering information For type

2CF ... – ... c C The rated voltages shown alongside are available at no extra cost.

Noise In the performance curves and selection tables, the noise values given are for an average sound-pressure level, measured at a distance of 1 m. The noise levels given are for a steadily-running machine, connected for extraction, and are evaluated according to DIN 45 635, Part 13. Tolerance is + 3 dB.

1.2 2.4 1.8 2 2

6) Permissible voltage tolerance ±5%. For dimensions, see page 66.

Selection example Required air performance: [ = 6 m3/min, at 50 Hz }pf = 1100 Pa Two selections are possible: Type 2CF2 072 ([ : -15 %), curve E Type 2CF2 082 ([ : +5 %), curve F Eventual choice depends on cost and performance priorities.

Applications • The extraction of gases from moulding presses and injection machines. • The extraction of dust, chips, fibres and threads when using a preseparator. • Holding of paper, cardboard. • Cooling.

Other designs Radial blowers with 3-phase motors for other voltages and/or frequencies are available on request. Accessories can also be supplied.

65

Dimensions for Radial Blowers 2CF1 and 2CF2

Dimensions for 2CF1 0, 2CF1 1, 2CF2 0 (mm) D2

D1

D3

B4

B2

B2 B3

M8

A5

B3 N K A3

R

M

A1

D4

D4

A1 A3

B4

E

A5

E

D3

D2

D1

PV-5145

A4

A2 A6

PV-5146c

A2

A4

C3

C7

C5 C6

C6

C7

C1 C3

C2

2CF1 052

C2

2CF1 142 to 2CF1 182

Type

Curve

A1

A2

A3

A4

A5

A6

B1

B2

B3

B4

C1

C2

C3

2CF1 052 - 0BA. 2CF1 052 - 1BH. 2CF1 142 - 0EA. 2CF1 182 - 0EA.

B B G H

70 70 210 260

70 70 180 230

50 50 140 180

100 100 275 350

80 80 250 320

100 100 – –

– – – –

85 85 180 230

50 50 140 180

22 22 35 45

– – 300 400

70 70 360 480

12 12 18 18

C4

C5

C6

C7

D1

D2

D3

D4

E

K

M

N

R

– – – –

– – 55 80

62 62 125 170

90 90 230 310

96 96 263 337

111 111 301 386

103 103 284 364

120 120 360 460

250 250 302 376

– – 4 x 11.5 4 x 14

– – 15 15

– – M 10 M 12

12 12 – –

E

B4

D1

D2

E

D2

D1

D3

4 x M6

A5 A3 A2

D4

D4

A3 A5

B3 B2 B1

B1

D3

26

B4

PV-5148

Curve B B G H

PV-5147a

Type 2CF1 052 - 0BA. 2CF1 052 - 1BH. 2CF1 142 - 0EA. 2CF1 182 - 0EA.

A1

Pg 16 26

16 C5

4x

A4

A4

C1

C1

2CF2 052 - 2EA1, 2CF2 052 - 2EH.

C6

C3 x C4

2CF2 062 to 2CF2 082

C2

C3 x C4 C7

C7

7

C5

C2

Type

Curve

A1

A2

A3

A4

A5

A6

B1

B2

B3

B4

C1

2CF2 052 - 2EA. 2CF2 052 - 2EH. 2CF2 062 - 0EA. 2CF2 072 - 0EA. 2CF2 082 - 0EA.

C C D E F

– – 110 120 130

– – 92 100 108

42.3 42.3 63 71 80

143 143 155 172 192

96 96 138 156 175

– – – – –

80 80 130 140 150

– – 108 118 129

– – 80 90 100

95 95 32 35 39

73 73 120 160 160

Type

Curve

C2

C3

C4

C5

C6

C7

D1

D2

D3

D4

E

2CF2 052 - 2EA. 2CF2 052 - 2EH. 2CF2 062 - 0EA. 2CF2 072 - 0EA. 2CF2 082 - 0EA.

C C D E F

120 120 160 200 200

12 12 12 12 12

16 16 16 16 16

62 62 51 54 57

– – 40 40 40

60 60 80 80 80

120 120 153 171 191

125 125 161 180 201

123 123 157 175 196

140 140 195 220 245

214 214 217 219 243

66

elmo vacuum technology GmbH

Dimensions for Accessories for Radial Blowers 2CF1 and 2CF2

Dimensions (mm) D C

65

4x 7

PV-5042

B A

PV-5043

B A

Connection piece for suction and pressure-side (to be used for hose, filter bag or heater cartridge) 60

D C

Connection piece for 2CF1

Connection piece for 2CF2

B

For ventilator Type

Connection piece for suction side Order No. A

B

C

D

for pressure-side Order No. A

B

C

D

2CF1 052 2CF2 062 2CF2 072 2CF2 082

2CX3 000 2CX3 726 2CX3 727 2CX3 728

46 73 88 93

84 108 118 129

100 130 140 150

2CX3 000 2CX3 705 2CX3 706 2CX3 726

46 63 68 73

84 92 100 108

100 110 120 130

54 80 95 100

54 70 75 80

B

Temperature range -55 to +150 °C: bending radius 12 to 75 mm; Hose can be compressed to 60 % of total length.

PV-5046a

PV-5045

2000

2500

Hose

A

A

Hose for 2CF1

Hose for 2CF2

For ventilator Type

Hose for suction side Order No.

2CF1 052 2CF2 052

2CX3 004 2CX3 717

54 83

2CF2 062 2CF2 072 2CF2 082

2CX3 717 2CX3 720 2CX3 721

83 95 102

A

for pressure-side Order No. A

B

58 72

2CX3 004 2CX3 722

54 51

58 51

72 102 102

2CX3 723 2CX3 724 2CX3 725

70 76 83

75 80 85

B

D

E

PV-5041

Metal filter complete with connection piece

4x

7 Metal filter for 2CF1 and 2CF2

B C

For ventilator Type

Order No.

2CF1 052 2CF2 052

2CX3 003 2CX3 730

50 70

2CF2 062 2CF2 072 2CF2 082

2CX3 731 2CX3 732 2CX3 733

70 100 102

B

C

D

E

84

1)

130 130

1)

108 118 129

130 180 180

165 180 180

140

1) The metal filter is supplied without connection piece, but with 2 m long plastic hose NW 83.

A 50

A

Filter bag complete with connection piece

B

C

B

PV-5048

PV-5047

Filter bag for 2CF1

Filter bag for 2CF2

C

Flow resistance of empty bag 500 Pa at [ = 2 m3/min For ventilator Type

Order No.

A

B

C

2CF1 052 2CF2 052

2CX3 002 2CX3 713

55 48

250 250

500 500

2CF2 062 2CF2 072 2CF2 082

2CX3 714 2CX3 715 2CX3 716

71 76 81

300 300 350

600 600 700

7

C A

PV-5044

Guard screen for suction-side

Guard screen for 2CF2

For ventilator Type

Order No.

A

C

2CF2 062 2CF2 072 2CF2 082

2CX3 735 2CX3 736 2CX3 737

130 140 150

108 118 129

84

Connecting elbow for 2CF1 elmo vacuum technology GmbH

PV-5040

55

57

57

130

PV-5039

270

Heater cartridge for 2CF1 052 Heating capacity: 1000 W; power connection: 230 V Flow resistance: approx. 550 Pa at [ = 1.2 m3/min

67

Radial Blower, Range 1BA

Selection diagram 1BA4 420 - 6FE04

1BE4 425 - 6JE03

300

5

270

4,5 4

210

3,5

180

3

150

2,5

120

2

90 60 30

These single-circuit radial blowers are particularly suitable for vacuum cleaners, small vacuum-transfer machines and pneumatic mail systems with short running times. The blowers have motors without fans. The air is sucked through a prefilter and simultaneously cools the motor. The blowers have commutator motors which are suitable for a 230 V, 50 Hz electrical supply. The service-life of the brushes (before re-machining the commutator) is given in the table below. The motor rotor, with bearings, should be replaced at the end of this period. Phase control and radio interference suppression are both possible.

0 300

Suction capacity V

Suction capacity V

240

300

5

270

4,5

m3/min

m3/h

m3/min

m3/h

240

4

210

3,5

180

3

150

2,5

120

2

1,5

90

1,5

1

60

1

0,5

30 0 300

APV-5333b

50 0 mbar 200 150 100 p Total pressure difference (vacuum)

0,5 APV-5334a

mbar 200 150 100 50 0 p Total pressure difference (vacuum)

Selection and ordering information Motor

Suction capacity max.

Vacuum max.

Order No.

Weight approx.

Average power consumption

Rated voltage

Frequency

Speed

Service life of brushes

W

V

Hz

rpm

h

m3/h

mbar

1100

230

50

32000 to 43200

850

184

235

1BA4 420 - 6FE01

1.6

1400

230

50

34000 to 47 000

850

206

271

1BA4 425 - 6JE03

1.7

Dimensions (mm)

PV-5331b

a

b

c

d

e

f

1BA4 420 - 6FE01

138.8

97.5

121.7

24.5

110.2

63.25

1BA4 425 - 6JE03

138.8

97.5

121.7

24.5

110.2

63.25

b a

e

Type

f

d

c

kg

Radial blower

68

elmo vacuum technology GmbH

Conversion Tables

Suction capacity

Pressure Multiplication of the value with units

With conversion factor

Results in the value with units

Multiplication of the value with units

With conversion factor

Results in the value in units

Pa

0.01

mbar

l/min

0.06

m3/h

hPa

1.0

mbar

gal/min

0.227

m3/h

kPa

10.0

mbar

ft3/min

1.699

m3/h

mm H2O

0.098

mbar

m3/h

16.667

l/min

m H2O

98.07

mbar

m3/h

4.403

gal/min

at

980.7

mbar

m3/h

0.588

ft3/min

inch H2O

2.491

mbar

PSI lpf/in2

68.948

mbar

mbar

100

Pa

mbar

10.2

mm H2O

Multiplication of the value with units

With conversion factor

Results in the value in units

mbar

10.2 · 10-3

m H2O

hp

0.746

kW

mbar

1.02 · 10-3

at

Btu/h

293.1

kW

mbar

0.4016

inch H2O

kW

1.341

hp

mbar

14.505 · 10-3

PSI lpf/in2

kW

3.41 · 10-3

Btu/h

Electrical power

Example of conversion:

Weight

250 [inch H2O] · 2.491 = 622.5 [mbar]

Multiplication of the value with units

With conversion factor

Results in the value in units

lbm

0.454

kg

kg

2.205

lbm

Multiplication of the value with units

With conversion factor

Results in the value in units

in.

25.4

mm

in.

0.0254

m

ft

305

mm

ft

0.305

m

m

39.37

in.

m

3.28

ft

The following formula is used to convert values in the unit — inch of mercury vacuum to values in the unit — mbar abs.ii: 1013 - X [inches of mercury vacuum] · 33.8 q Y [mbar abs.]

Length

Types of pressure • Absolute pressure The pressure measured from absolute zero, using ideal vacuum as the datum. The measured pressure is always greater than the reference pressure. • Total pressure difference, pressure The pressure measured above the prevailing atmospheric pressure. The datum is the prevailing atmospheric pressure and the measured pressure is always higher than the datum. • Total pressure difference, vacuum The pressure measured lower than the prevailing atmospheric pressure. The datum is the prevailing atmospheric pressure and the measured pressure is always lower than the datum.

Total pressure difference (vacuum)

Temperature conversion

Total pressure difference (gauge)

to

°F

K

°F

°C

K

°F

t [°F] = 1.8 · T [K] - 459.67

°C

°F

t [°F] = 1.8 · t [°C] + 32

T [K] =

t [°F] + 459.67 1.8

t [°C] =

t [°F] - 32 1.8

A PV-5057a

Absolute pressure

Conversion from

100% vacuum 0 mbar

elmo vacuum technology GmbH

Atmosphere Biometric pressure approx. 1013 mbar

69

General Safety Information

NOTE: The products in this catalogue are used in the • capital goods industry • consumer goods industry

and in such sectors as • agriculture • the building industry and • allied trades. This equipment has bare parts that are dangerous because they are live during operation, in some cases these are moving or rotating parts. Such parts could cause severe injury to persons and severe damage to property, for example in the event of unauthorised removal of protective covers, improper use, wrong operation or insufficient maintenance. The people in charge of safety must therefore guarantee that • only qualified personnel are allowed to work

on or around this equipment;

supplied with the equipment, and are under an obligation to systematically follow the instructions given therein; • unqualified personnel are not allowed to work on these machines or equipment or in the vicinity thereof. Qualified personnel are persons who – on account of their training, experience, instruction, knowledge of the appropriate standards, specifications, accident prevention regulations and the operating enviroment – have been authorised by those responsible for plant safety to perform the necessary work and at the same time to recognise and circumvent potential hazards. Knowledge of first aid and familiarity with the pertinent life-saving equipment are also necessary. The debarring of unqualified personnel from work on heavy-current equipment is regulated by DIN VDE 0105 or IEC 364.

variations, or to provide for every possible contingency that might arise in installation, operation or maintenance. The operating instructions therefore only contain the information necessary to enable qualified personnel (see above) to operate the machines or equipment correctly in industrial applications. In the event that the machines or equipment are intended for service outside of industry, where more exacting demands may be placed on them (such as touch protection for children), the installation work must be supplemented by further protective measures that are to be implemented by others. Where clarifications are necessary, particularly with respect to lack of product-specific detailed information, please contact the sales office concerned, quoting the type designation of the machine or equipment. It is advisable to arrange for our service centres to take charge of the necessary planning, installation, commissioning and after-sales service.

• this personnel have access at all times while

working on the equipment to the appropriate operating instructions and other documents

70

For the sake of clarity, the operating instructions supplied with the machines are not intended to cover all details of equipment

elmo vacuum technology GmbH

Conditions of Sale and Delivery, Export Regulations Small orders With small orders, the costs of handling the order exceed the value of the order. It is recommended that requirements are added together. If this is not possible, we will be obliged to charge a handling supplement of EUR 20.- for orders with a net goods value of less

than EUR 100.– to cover a proportion of our costs for order handling and invoicing.

Ordering special versions If products are orders that are different from the versions given in the catalogue, a “–Z” is to be added to the order number given in the catalogue, and the required characteristic is then also to be added in full text.

Conditions of Sale and Delivery Within Germany:

For export:

The General Conditions of Sale apply, plus the

The General Conditions of Delivery for products and services from the electrical industry and all other conditions agreed with the recipients of the price lists.

General Conditions of Delivery for electrical products and services. Prices are given in EURO ex factory, excluding packaging; this is charged at cost.

a Unless otherwise stated on the individual pages of this catalogue, we reserve the right to make changes, especially to the given values, dimensions and weights. Illustrations are not binding.

Value-added tax is not included in the prices. It will be charged at the rate valid at the time in accordance with the requirements of the law.

We also reserve the right to make price modifications and will charge the prices valid on delivery.

Export regulations According to the current provisions (09/98) of the German and US export regulations, the products listed in this catalogue do not require any export permit. Export or re-export is therefore allowed without the permission of the competent authorities unless the Order on

Trade marks

Foreign Trade lays down country-specific restrictions. The markings given on the delivery slip and invoice are the decisive criteria. An export permit obligation may arise for specific countries as a result of the intended use of the products.

All product designations are trade marks or product names of elmo vacuum technology GmbH or other companies.

elmo vacuum technology GmbH

Responsible for the technical content Lutz Kasimir elmo vacuum technology GmbH Marketing Communication

71

Only Quality Has a Future

Electronic check of the dimension accuracy of an ELMO-G impeller.

Fully automatical final check of endshields of ELMO-F and -G drives.

Technical progress and market success are inseparable from the high quality of ELMO vacuum pumps and compressors. To guarantee this high quality level, a reliable quality assurance system has been established for monitoring all phases of production from development to delivery.

This quality assurance system meets the worldwide requirements, corresponds with the relevant standards and specifications and fulfils the requirements of ISO 9001. This gives our customers the following advantages: maximum operational safety; high, consistent supply reliability; • compliance with the requirements of the European Market; • participation in national and international tenders. • •

Check of performance data and printing of the test protocol.

72

elmo vacuum technology GmbH

Your direct contact to elmo

Sales region

Address

Contact

Telephone

Fax

elmo vacuum technology GmbH A Siemens Company Humboldtstraße 59 D-90459 Nürnberg Germany

Mr. J. Müller, Dep. M BD2 [email protected]

+49 (911) 433-7773

+49 (911) 433-6935

Siemens E&A, Inc Dep. IPD/VP&C 4620 Forest Ave Norwood, OH 45212 USA

[email protected] www.siemensvpc.com/sales

+1 (513) 841-3300

+1 (513) 841-3302

Mr. Leslie J. Croyston [email protected]

+65 845-4780

+65 845-4789

Siemens Ltd. 885, Mountain Highway Bayswater, Vic. 3153 Australia

Mr. Glenn Plymin, Dep. A&D [email protected]

+61 (3) 9721-7542

+61 (3) 9721-7908

Siemens Vacuum Pump & Compressor Co. Ltd. No. 448, BaiYucheng ZiBo 255213 BoShan, ZiBo, ShangDong Rep. of China

Mrs. Qiulan Liu, Dep. elmo GM [email protected]

+86 (533) 465-4800

+86 (533) 465-0166

Europe Headquarters Europe

America Headquarters NAFTA

Asia Headquarters Asia Pacific elmo vacuum technology Pte. Ltd. A Siemens Company Blk 164 Kallang Way, #04-38 Singapore 349248 Australia Headquarters Australia

China Headquarters China

The above table shows our regional headquarters worldwide. For your local contact partner, please take a look in our Internet site under www.elmo-vacuum.com >> contacts or contact the regional office for further assistance.