ELMO-F Vacuum Units with Vacuum Pumps, Range 2BE Selection example Application:
Vacuum Pumps
Compressors
100.000 m /h
30.000
10.000
10.000
Hybrid systems with roots fans
Hybrid gas-jet systems
Single-stage liquid-ring vacuum pumps 2BV or 2BE
Single-stage, double-action liquid-ring compressors 2BK, also combined with 2BE
Single-stage, single action liquid-ring vacuum pumps 2BV or 2BE
100
0,001
0,01
0,03
0,1
1,013
0,2 0,2
a Duty point: . V = 570 m3/h at 50 Hz p1 = 100 mbar
m /h 3
30.000
1000
e.g. foundry machines, casting technology
100.000 Multipump systems
3
2
3
10
Vacuum in bar
14
d Selection and order code: ELMO-F vacuum unit with vacuum pump 2BE1 153 - 0 No. 157 E r Type 2BE1 153-0BY4-Z F43+F44+F97 Motor 1LA5 183 - 4AA60 1) Note: When ordering motor, always indicate as separate item.
1000
Double-stage liquid-ring compressors 2BG, also combined with 2BE
7
5
s Choose the performance curve which lies closest to the duty point a. In this example, No. 157 E
100
ELMO systems as standard or customer-specific solutions covering a wide range of uses: from 1 mbar to 14 bar, from 10 to 100,000 m3/h
20
Pressure in bar
Selection and ordering examples for applications in the machine tools industry Selection diagram
Suction capacity V
3000
APV-5018e
m3/h 253E 2000
2) Motor should be ordered separately. For prices, other voltages etc., see Siemens price list M11. 3) Permissible voltage range: Degree of protection
Rated voltage acc. to DIN IEC 38
perm. Voltage range acc. to DIN VDE or DIN IEC 34-1
IP 55
400 V D / 690 V Y **
EEx e II T3
400 V D / 690 V Y **
380...420 V D / 660...725 V Y *** 400 V D / 690 V Y *
* Voltage tolerance here ±5% ** Voltage tolerance here ±10%
1500 252E
*** This voltage range is also shown on the rating plate, together with the currents occuring in this range. For this range, the permissible voltage tolerance acc. to DIN VDE 0530 or IEC 34-1 is ±5%
1000 203E
4) Based on operating duty “Standard” for inlet pressures: 2BE1: < 200 / W 200 mbar abs.
800 600 400
5) Measuring-surface sound-pressure level acc. to EN 21680-1, measured at 1 m distance in a free field, at medium inlet pressure and with inlet and discharge pipes connected. Tolerance: +3 dB.
202E 157E
300 30
1 2 Selection example
50
6) Special materials of construction, gaskets, motors and expanded scope of supply available on request.
Suction capacities from 20 to 500 m3 /h on request
80 100
200 300
500 mbar 1013
Inlet pressure (abs.) p 1
F
1) Scope of supply: 2BE1: vacuum pump with internal sealant supply, complete with mounted manifold, discharge-liquid separator, coupling, coupling guard and baseplate; without motor.
7) See accessories. 8) Including motor. For dimensions, see page 61.
The selection diagram corresponding to PNEUROP with a tolerance of ±10% for: • The evacuation of 100% saturated air with a temperature of 20 °C (68 °F). • Discharge pressure is 1013 mbar. • The operating liquid is water with a temperature of 15 °C (59 °F).
Selection and ordering information Curve No.
Motor Rated output
Vacuum pump Motor - Order No. 2)
Rated voltage 3)
Rated current
V
A
1LA5 183 - 4AA60 1MA6 186 - 4BC80 1LA5 207 - 6AA60 1MA6 207 - 6BC80 1LA5 223 - 6AA60 1MA6 253 - 6BC80 1LA6 283 - 8AB60 1MJ6 283 - 8CB60 1LA6 313 - 8AB60 1MJ6 313 - 8CB60
400 D / 690 Y 400 D / 690 Y 400 D / 690 Y 400 D / 690 Y 400 D / 690 Y 400 D / 690 Y 400 D / 690 Y 400 D / 690 Y 400 D / 690 Y 400 D / 690 Y
35 D / 20.2 Y 33.5 D / 19.3 Y 45.5 D / 26.3 Y 39 D / 22.5 Y 61 D / 35.3 Y 66 D / 38.2 Y 84 D / 48.5 Y 84 D / 48.5Y 138 D / 80 Y 138 D / 80 Y
kW d
157E 202E 203E 252E 253E
58
18.5 17.5 22 20 30 33 45 45 75 75
Operating fluid requirement 4)
Soundpressure level 5)
Degree of protection
Rated speed rpm
m3/h
dB(A)
IP 55 EEx e II T3 IP 55 EEx e II T3 IP 55 EEx e II T3 IP 55 EEx de II C IP 55 EEx de II C
1460 1470 975 980 980 985 730
1.9 / 1.3
70
2.1 / 1.4
71
2.6 / 1.7
71
4.4 / 2.9
73
740
5.2 / 3.5
73
Order No. 6) Vacuum pump
Accessories + mounting 7)
2BE1 153-0 B Y 4 - Z 2BE1 153-0 B Y 4 - Z 2BE1 202-0 B Y 4 - Z 2BE1 202-0 B Y 4 - Z 2BE1 203-0 B Y 4 - Z 2BE1 203-0 B Y 4 - Z 2BE1 252-0 B Y 4 - Z 2BE1 252-0 B Y 4 - Z 2BE1 253-0 B Y 4 - Z 2BE1 253-0 B Y 4 - Z
F43 + F44 + F97 F43 + F44 + F98 F43 + F44 + F97 F43 + F44 + F97 F43 + F44 + F96 F43 + F44 + F97 F43 + F44 + F97 F43 + F44 + F97 F43 + F44 + F97 F43 + F44 + F97
Total weight 8) kg 432 500 825 870 815 1000 1690 1710 2110 2150
elmo vacuum technology GmbH
236
266
288
elmo vacuum technology GmbH
14000 316
16000 346
9500 200
18000 390
10700 220
6800 132
All figures are for guidance only. For precise design, please ask for our catalogue sheets or contact your nearest office.
20500 500
12400 275
7400 160
Speed performance area of 2BE1 pumps
Speed of pump in rpm
210
8200 220
5000 110
22500 630
14000 315
330
Selection overviews for range 2BE1
9300 250
5600 132
3400 75
m3/h kW
15400 390
372
472
530
m3/h kW
5800 160
3600 80
2100 45
2BE1 403 - 0
2BE1 503 - 0
m3/h kW
4700 132
4400 110 8000 250
3200 65
1700 38
m3/h kW
1450 32
m3/h kW
4000 100
2400 54
1650 38 2650 65
1850 46
1000 23
2950 83
2050 58
1120 27
1240 33
840 22
440 10.8
m3/h kW
2BE1 153 - 0 760 18
340 8.1
m3/h kW
2BE1 152 - 0 660 16
290 7
1400 44.2
940 30
510 13.5
400 10.5
360 9
290 7
m3/h kW
2BE1 103 - 0 m3/h kW
200 4.9
m3/h kW
2BE1 102 - 0
1300
150 3.6
1100
m3/h kW
980
2BE1 101 - 0
920
2BE1 151 - 0
880
2BE1 303 - 0
820
2BE1 353 - 0
m3/h kW
840 20
m3/h kW
2BE1 203 - 0
790
580 13.5
740
m3/h kW
660
2BE1 202 - 0
590
2800 56
1150 26
565
m3/h kW
2BE1 603 - 0
11600 346
7200 200
4200 90
2BE1 703 - 0
m3/h kW
10500 275
6400 160
3700 75
2550 50
2BE1 253 - 0
2BE1 252 - 0
420
1450
600 16.5
460 12.4
400 11
330 8.2
235 5.8
175 4.3
1625
660 19.5
500 15
440 13
380 10
270 6.9
190 5
1810
710 24
540 18.1
480 16
2190
490 16
340 11.1
250 8.3
Selection Overviews for Range 2BE1
F
59
60
190
200
210
18500 270
14900 220
15200 250
13000 190
21000 335
12500 205
10700 160
23500 380
17800 280
9000 kW 130
m3/h
7400 kW 110
m3/h
230
2BE3 52. - 2
2BE3 50. - 2
All figures are for guidance only. For precise design, please ask for our catalogue sheets or contact your nearest office.
Speed performance area of 2BE3 pumps
Speed of pump in rpm
180
26400 470
20500 345
240
270
17200 295
14100 240
10500 170
8600 138
29400 550
22700 410
2BE3 42. - 2
2BE3 40. - 2
260
300
19100 340
15800 280 20900 395
17100 325
320
330
32500 640
24900 26400 27200 475 525 545
12100 210
10000 170
5600 kW 82
m3/h
4100 kW 63
m3/h
290
F
170
Selection overviews for range 2BE3
37000 805
13700 245
9200 205
6500 108
4800 80
340
30500 675
370
m3/h kW
15050 285
12300 287
380
m3/h 2BE3 72. - 2 kW
22800 426
18700 375
350
420
25500 575
21200 470
2BE3 60. - 2
8400 160
6150 113
3750 kW 62
18500 415
9200 180
6750 130
4100 70
490
2900 51
15100 338
470
m3/h
450
m3/h 2700 kW 45
440
m3/h 2BE3 62. - 2 kW
kW
m3/h
16600 335
13600 276
2BE3 32. - 2
2BE3 30. - 2
400
2BE3 67. -2
7500 130
5500 95
390
9950 210
7300 149
530
4700 85
3300 60
560
8400 185
610
10700 11400 230 270
7800 168
570
5200 100
3700 71
630
5600 116
4000 81
690
6000 126
4300 91
740
6500 151
4700 109
810
Selection Overviews for Range 2BE3
elmo vacuum technology GmbH
Dimensions for ELMO-F Units 2BE and Accessories Dimensions for 2BE1 15. to 2BE1 25. (mm) PV-5028
N2.2 N1.1 N4.0 N2.0
H3
H1
N1.0
H2
N3.0
B
L L1 2BE1 153 to 2BE1 253
2BE1 Type
Curve No.
For motor size:
B
H1
H2
H3
L
L1
Vacuum-/pressure-side pipe socket N1.0/N2.0 DN DIN 2501 PN 10
N1.1/N2.2 DN DIN 2501 PN 10
N3.0 Connection for op. liquid ISO 7/1
N4.0 Drain of separator ISO 7/1
2BE1 153
157 E 158 E
180M 180L
450
845
325
700
1265
1610
65
100
Rp ¼
Rp 2
2BE1 202
202 E 204 E 203 E 206 E
200L
660
1085
415
940
1625
1755
100
125
Rp 1
Rp 3
225M 250M
660
1110
415
965
1625
1935 2030
100
125
Rp 1
Rp 3
252 E 254 E 253 E 256 E
280M
630
1400
555
1185
1800
2255
125
150
Rp 1¼
Rp 3
315M
700
1400
555
1185
2060
2540
125
150
Rp 1¼
Rp 3
2BE1 203 2BE1 252 2BE1 253
Accessories 2BE For vacuum pump Type
Order No.
Weight kg
Compressed-air gauge, loose Chrome-nickel steel
0.8 - 4 m3/h
2BE1 15. to 2BE1 20.
2BX9 284 - 0HX02
8
for operating liquid
0.8 - 4 m3/h
2BE1 25.
2BX9 284 - 0HX03
14
2BE1
2BX9 012 - 1HD20
1
Pressure gauge -1 to +0.6 bar including shutoff tap and gaskets
Order codes Discharge-liquid separator
F43
Manifold
F44
Coupling, coupling protection, baseplate incl. motor mounting
F96, F97, F98
elmo vacuum technology GmbH
F
61
ELMO-F Systems
Standard closed-circuit units Key: M
010 030 080 130
030 010 PV-5054
N1.0
Connections: Vacuum pump Three-phase motor Separator Heat exchanger
280 N6.0
130
N1.0 N2.2 N3.3 N4.0 N4.1 N5.0 N6.0 N8.6
Gas inlet Gas outlet Make-up Overflow Total drain Cooling water inlet Cooling water outlet Measurement point
170
N5.0 260
N2.2
080
N4.0 N3.3 N8.6 N4.1
LG
ELMO-F closed-circuit vacuum pump range 2BW3 The ELMO-F Standard closed-circuit vacuum pumps/compressors 2BW consist of a vacuum pump/compressor with three-phase motor, liquid separator, heat exchanger, base frame and pipework. The schematic structure is shown in the picture above right.
With ELMO-F closed-circuit vacuum pumps/compressors 2BW, the condensate from the extracted process vapours is conveyed as the operating liquid in a closed circuit (vacuum pump/compressor ) separator ) heat exchanger ) vacuum pump/compressor). This prevents polluted waste water and avoids the need to use fresh water. Recovered condensate can be removed for further use. The cooling water is only heated up, not polluted.
Closed-circuit vacuum pump with roots backing pump
M 020 N1.1
(
M 010
N2.2 N4.0
163 080
N3.3
Key:
Connections:
010 Vacuum pump with motor 020 Roots backup pump 080 Separator, vertical 130 Heat exchanger 163 Non-return valve
N1.1 N2.2 N3.3 N3.4 N4.0 N4.1 N5.0 N6.0 N8.9
Gas inlet Gas outlet Make-up TI measurement nozzle Overflow Total drain Cooling water inlet Cooling water outlet Measurement point
N8.9 N4.1 130 N3.4
F
PV-5314b
N5.0 N6.0
ELMO-F closed-circuit vacuum pump with roots backing pump for inlet pressures to 10 mbar abs. Further versions: ELMO-F vacuum pumps with backing pumps like gas ejectors, steam ejectors, roots pumps (see figure above) and ELMO-G for low limit pressure from 1 to 100 mbar abs. ELMO-F plants with several parallel vacuum pumps and compressors for higher suction capacities.
62
To optimize the speed of ELMO-F closed-circuit vacuum pumps and compressors in accordance with the required process data, the following drives are possible:
For a flexible matching of ELMO-F closed-circuit vacuum pumps and compressors to the process data, the following control concepts can be supplied:
• Direct drive via coupling with electrical or other motors (e.g. Diesel motor) • Drive via belt drive with electrical or other motors (e.g. Diesel motor) • Drive via gear with electrical or other motors (e.g. Diesel motor)
• Bypass control, • Speed control with frequency converters when using electrical motors, • Process-bound complete control systems for plants
elmo vacuum technology GmbH
ELMO-F Systems
Vacuum system with roots backing pump and gas ejector
Series-connected ELMO-F compressors
Process
Gas ejector
Roots blower
Process
(
ELMO-F vacuum pump
Process
Process ELMO-F 2BE compressor
Separator
ELMO-F 2BG compressor
) Separator
Heat exchanger
Heat exchanger 1 mbar
1400 mbar
Sets for the range to 1 mbar.
Separator
800 mbar
Heat exchanger 14 bar
Series connection of ELMO-F compressors for use up to 14 bar abs.
When combined with reliable components such as roots pumps or gas ejectors, the area of use of ELMO-F compressors is considerably extended. Even mixed operation from vacuum to pressure presents no problems for the machines.
Examples of vacuum/compressor systems with ELMO-F pumps
Double unit 2BW4 203 - 0ZY99 - Z Suction flow: N2, Dichlorethane (EDC), VC, HCL Suction capacity: 105 Nm3/h Vacuum: 0.16 bar abs. Pressure: 1.7 bar abs. Drive capacity: 38 kW
F Power unit 2BW4 253 - 0BL4. - Z with gas ejector Condenser evacuation Suction flow: Vapour-air mixture Leakage air flow evaporation: 10.32 kg/h Vacuum: 0.015 bar abs. Drive capacity: 47 kW
elmo vacuum technology GmbH
63
Radial Blowers Range 2CF1 and 2CF2
Selection diagram 50 Hz Pa
40
4000
A PV-5020c
90dB(A)
30
20 16 12
Pressure difference
pf
mbar
3000
86
2000
75
1600
77
76
1200
10
1000
8
800
6
600
5
500
4
400
3
300
2
200
1
100 1
91
87
71
61
81
82 79
78
68
C
B
68 1,5
D
84
2
E
83
3
4
F
80
5
6
G
85
7 8 9 10 12
H
92 16
96 3
30 m /min 50 60
20
Capacity V 60
80 100
150
200
300
400 500
700
m3/h
1400 2000
1000
3600
Selection diagram 60 Hz mbar
Pa
40
4000
A PV-5104c
86dB(A)
pf
20 16 12
Pressure difference
30
3000
72
1600
77
77 1200
10
1000
8
800
6
600
5
500
4
400
3
300
2
200
1
100 1
83
64
84
91
87
63 79
79
70
C
The performance curves are valid for a medium with a density r = 1.2 kg/m³ (measured on the suction side).
86
77
2000
B
84
70 1,5
2
D
3
4
84 5
E
86 6
F
G
87
7 8 9 10 12
H
96
92 16
30 m3/min 50 60
20
Capacity V 60
80 100
150
200
300
400 500
700
1000
1400
2000
m3/h
3600
elmo vacuum technology GmbH
Radial Blowers Range 2CF1 and 2CF2 and Accessories Selection and ordering information Size
Designation letter
mm
Speed
rpm
Soundpressure level at 1 m distance 1) dB(A)
Other voltages
Tempe- Motor rature of Type conveying liquid 2) max.°C
Order No. Rated output kW
Rated voltage 3)
Rated current
V
Weight approx.
•AVAILABLE EX
kg
0.34 5) 0.36 5) 0.52 5) 0.69 5) 1.2 5) 2.6 5) 8.2 5)
•2CF1 052 - 0BA1 •2CF2 052 - 2EA 1 •2CF2 062 - 0EA 1 •2CF2 072 - 0EA 1 •2CF2 082 - 0EA 1 •2CF1 142 - 0EA 1 •2CF1 182 - 0EA 6
6.2 4.3 8.8 10.2 12.5 30 74
0.35 0.23 0.58 0.68 1.35 2.3 7.3
2CF1 052 - 0BA8 2CF2 052 - 2EA 8 •2CF2 062 - 0EA 1 2CF2 072 - 0EA 8 2CF2 082 - 0EA 8 2CF1 142 - 0EA 8 2CF1 182 - 0EA 8
6.2 4.3 8.8 10.2 12.5 30 74
0.85 0.80
•2CF1 052 - 1BH1
6.2 4.5
STOCK
A
Radial blowers with three-phase motor 50 Hz, IP 54 degree of protection 50 50 63 71 80 140 180
B C D E F G H
7350 4) 2850 2780 2750 2740 2900 2890
79 68 78 82 82 87 91
65 50 110 110 110 65 65
1LA5 053 1PP4 060 1LA5 060 1LA5 063 1LA5 070 1LA5 083 1LA5 113
0.12 0.06 0.18 0.25 0.42 1.17 4.2
230 d/ 400 * 230 d/ 400 * 230 d/ 400 * 230 d/ 400 * 230 d/ 400 * 230 d/ 400 * 400 d/ 690 *
Radial blowers with three-phase motor 60 Hz, IP 54 degree of protection 50 50 63 71 80 140 180
B C D E F G H
7350 4) 3300 3240 3300 3280 3480 3480
79 70 79 83 84 87 91
65 50 110 110 110 65 65
1LA5 053 1LA5 050 1LA5 060 1LA5 063 1LA5 073 1LA5 083 1LA5 113
0.14 0.09 0.24 0.29 0.63 1.27 4.2
460 * 460 * 460 * 460 * 460 * 460 * 460 *
Radial blowers with single-phase AC motor 50 Hz, IP 54 degree of protection 50 50
B C
7490 4) 2850
79 68
60 50
1LF5 053 1LF4 063
0.12 0.09
230 6) 230 6)
2CF2 052 - 2EH 1
Accessories for dischargeside
Weight approx.
Hose for inletside
Weight approx.
for dischargeside
Weight approx.
Metal filter for inletside
Weight approx.
Order No.
kg
Order No.
kg
Order No.
kg
Order No.
kg
Order No.
kg
2CF1 052 2CF2 052 2CF2 062 2CF2 072 2CF2 082
•2CX3 000
0.45
•2CX3000
0.45
1.5 1.2 1.2 1.3 1.4
•2CX3 004
1.5 0.7 1.1 1.2 1.2
•2CX3 730 •2CX3 731 •2CX3 732
For type
0.24 0.28 0.30
not necessary •2CX3 705 •2CX3 706 2CX3 726
Filter bag for dischargeside
Weight approx.
Guard screen for inletside
Order No.
kg
Order No.
0.19 0.22 0.24
2CX3 004
•2CX3 717 •2CX3 717 2CX3 720 2CX3 721
2CX3 722 2CX3 723 2CX3 724 2CX3 725
2CX3 003
2CX3 733
Weight approx.
Connecting elbow Weight approx.
Heating cartridge •AVAILABLE EX for dischargeWeight STOCK side approx.
kg
Order No.
Order No.
kg
kg
2CF1 052 2CF2 052
2CX3 002 2CX3 713
0.75 1.5
– –
– –
2CX3 001 –
1.8 –
2CX3 005 –
0.75 –
2CF2 062 2CF2 072 2CF2 082
2CX3 714 2CX3 715 2CX3 716
1.5 1.5 1.5
2CX3 735 2CX3 736 2CX3 737
0.22 0.25 0.27
– – –
– – –
– – –
– – –
Features The blower and motor form a single unit with the impeller mounted directly on the motor shaft. Only the types 2CF1 052-0BA. and 2CF1 052-1BH. have a gearbox between the impeller and the motor. Drive The blowers have surface-cooled, three-phase or single-phase motors with IP 55 class of protection. They are suitable for continuous operation.
elmo vacuum technology GmbH
Voltage code number
500 V *, 50 Hz
3
Required voltage and frequency: C
9
C Please indicate in plain text and add L1 Y. 1) The tabulated values are with medium throttling. 2) Max. ambient temperature 40 °C. 3) Permissible voltage range. Rated voltage acc. to DIN IEC 38*
Permissible voltage range acc. to DIN VDE 0530 or DIN IEC 34-1**
Frequency Hz
230 V D / 400 V Y 220...240 V D / 380...420 V Y 50 400 V D / 690 V Y 380...420 V D / 660...725 V Y 50 460 V Y 460 V D
440...480 V Y 440...480 V D
60 60
* Voltage tolerance here ±10%. ** This voltage range is also shown on the rating plate, together with the currents occuring in this range. For this range, the permissble voltage tolerance acc. to DIN VDE 0530 or DIN IEC 34-1 is ±5%. 5) At 400 V, 50 Hz.
Duct connector for inletWeight side approx.
not necessary 2CX3 726 2CX3 727 •2CX3 728
Voltage, frequency
4) 2-pole motor with gearbox.
Selection and ordering information For type
2CF ... – ... c C The rated voltages shown alongside are available at no extra cost.
Noise In the performance curves and selection tables, the noise values given are for an average sound-pressure level, measured at a distance of 1 m. The noise levels given are for a steadily-running machine, connected for extraction, and are evaluated according to DIN 45 635, Part 13. Tolerance is + 3 dB.
1.2 2.4 1.8 2 2
6) Permissible voltage tolerance ±5%. For dimensions, see page 66.
Selection example Required air performance: [ = 6 m3/min, at 50 Hz }pf = 1100 Pa Two selections are possible: Type 2CF2 072 ([ : -15 %), curve E Type 2CF2 082 ([ : +5 %), curve F Eventual choice depends on cost and performance priorities.
Applications • The extraction of gases from moulding presses and injection machines. • The extraction of dust, chips, fibres and threads when using a preseparator. • Holding of paper, cardboard. • Cooling.
Other designs Radial blowers with 3-phase motors for other voltages and/or frequencies are available on request. Accessories can also be supplied.
65
Dimensions for Radial Blowers 2CF1 and 2CF2
Dimensions for 2CF1 0, 2CF1 1, 2CF2 0 (mm) D2
D1
D3
B4
B2
B2 B3
M8
A5
B3 N K A3
R
M
A1
D4
D4
A1 A3
B4
E
A5
E
D3
D2
D1
PV-5145
A4
A2 A6
PV-5146c
A2
A4
C3
C7
C5 C6
C6
C7
C1 C3
C2
2CF1 052
C2
2CF1 142 to 2CF1 182
Type
Curve
A1
A2
A3
A4
A5
A6
B1
B2
B3
B4
C1
C2
C3
2CF1 052 - 0BA. 2CF1 052 - 1BH. 2CF1 142 - 0EA. 2CF1 182 - 0EA.
B B G H
70 70 210 260
70 70 180 230
50 50 140 180
100 100 275 350
80 80 250 320
100 100 – –
– – – –
85 85 180 230
50 50 140 180
22 22 35 45
– – 300 400
70 70 360 480
12 12 18 18
C4
C5
C6
C7
D1
D2
D3
D4
E
K
M
N
R
– – – –
– – 55 80
62 62 125 170
90 90 230 310
96 96 263 337
111 111 301 386
103 103 284 364
120 120 360 460
250 250 302 376
– – 4 x 11.5 4 x 14
– – 15 15
– – M 10 M 12
12 12 – –
E
B4
D1
D2
E
D2
D1
D3
4 x M6
A5 A3 A2
D4
D4
A3 A5
B3 B2 B1
B1
D3
26
B4
PV-5148
Curve B B G H
PV-5147a
Type 2CF1 052 - 0BA. 2CF1 052 - 1BH. 2CF1 142 - 0EA. 2CF1 182 - 0EA.
A1
Pg 16 26
16 C5
4x
A4
A4
C1
C1
2CF2 052 - 2EA1, 2CF2 052 - 2EH.
C6
C3 x C4
2CF2 062 to 2CF2 082
C2
C3 x C4 C7
C7
7
C5
C2
Type
Curve
A1
A2
A3
A4
A5
A6
B1
B2
B3
B4
C1
2CF2 052 - 2EA. 2CF2 052 - 2EH. 2CF2 062 - 0EA. 2CF2 072 - 0EA. 2CF2 082 - 0EA.
C C D E F
– – 110 120 130
– – 92 100 108
42.3 42.3 63 71 80
143 143 155 172 192
96 96 138 156 175
– – – – –
80 80 130 140 150
– – 108 118 129
– – 80 90 100
95 95 32 35 39
73 73 120 160 160
Type
Curve
C2
C3
C4
C5
C6
C7
D1
D2
D3
D4
E
2CF2 052 - 2EA. 2CF2 052 - 2EH. 2CF2 062 - 0EA. 2CF2 072 - 0EA. 2CF2 082 - 0EA.
C C D E F
120 120 160 200 200
12 12 12 12 12
16 16 16 16 16
62 62 51 54 57
– – 40 40 40
60 60 80 80 80
120 120 153 171 191
125 125 161 180 201
123 123 157 175 196
140 140 195 220 245
214 214 217 219 243
66
elmo vacuum technology GmbH
Dimensions for Accessories for Radial Blowers 2CF1 and 2CF2
Dimensions (mm) D C
65
4x 7
PV-5042
B A
PV-5043
B A
Connection piece for suction and pressure-side (to be used for hose, filter bag or heater cartridge) 60
D C
Connection piece for 2CF1
Connection piece for 2CF2
B
For ventilator Type
Connection piece for suction side Order No. A
B
C
D
for pressure-side Order No. A
B
C
D
2CF1 052 2CF2 062 2CF2 072 2CF2 082
2CX3 000 2CX3 726 2CX3 727 2CX3 728
46 73 88 93
84 108 118 129
100 130 140 150
2CX3 000 2CX3 705 2CX3 706 2CX3 726
46 63 68 73
84 92 100 108
100 110 120 130
54 80 95 100
54 70 75 80
B
Temperature range -55 to +150 °C: bending radius 12 to 75 mm; Hose can be compressed to 60 % of total length.
PV-5046a
PV-5045
2000
2500
Hose
A
A
Hose for 2CF1
Hose for 2CF2
For ventilator Type
Hose for suction side Order No.
2CF1 052 2CF2 052
2CX3 004 2CX3 717
54 83
2CF2 062 2CF2 072 2CF2 082
2CX3 717 2CX3 720 2CX3 721
83 95 102
A
for pressure-side Order No. A
B
58 72
2CX3 004 2CX3 722
54 51
58 51
72 102 102
2CX3 723 2CX3 724 2CX3 725
70 76 83
75 80 85
B
D
E
PV-5041
Metal filter complete with connection piece
4x
7 Metal filter for 2CF1 and 2CF2
B C
For ventilator Type
Order No.
2CF1 052 2CF2 052
2CX3 003 2CX3 730
50 70
2CF2 062 2CF2 072 2CF2 082
2CX3 731 2CX3 732 2CX3 733
70 100 102
B
C
D
E
84
1)
130 130
1)
108 118 129
130 180 180
165 180 180
140
1) The metal filter is supplied without connection piece, but with 2 m long plastic hose NW 83.
A 50
A
Filter bag complete with connection piece
B
C
B
PV-5048
PV-5047
Filter bag for 2CF1
Filter bag for 2CF2
C
Flow resistance of empty bag 500 Pa at [ = 2 m3/min For ventilator Type
Order No.
A
B
C
2CF1 052 2CF2 052
2CX3 002 2CX3 713
55 48
250 250
500 500
2CF2 062 2CF2 072 2CF2 082
2CX3 714 2CX3 715 2CX3 716
71 76 81
300 300 350
600 600 700
7
C A
PV-5044
Guard screen for suction-side
Guard screen for 2CF2
For ventilator Type
Order No.
A
C
2CF2 062 2CF2 072 2CF2 082
2CX3 735 2CX3 736 2CX3 737
130 140 150
108 118 129
84
Connecting elbow for 2CF1 elmo vacuum technology GmbH
PV-5040
55
57
57
130
PV-5039
270
Heater cartridge for 2CF1 052 Heating capacity: 1000 W; power connection: 230 V Flow resistance: approx. 550 Pa at [ = 1.2 m3/min
67
Radial Blower, Range 1BA
Selection diagram 1BA4 420 - 6FE04
1BE4 425 - 6JE03
300
5
270
4,5 4
210
3,5
180
3
150
2,5
120
2
90 60 30
These single-circuit radial blowers are particularly suitable for vacuum cleaners, small vacuum-transfer machines and pneumatic mail systems with short running times. The blowers have motors without fans. The air is sucked through a prefilter and simultaneously cools the motor. The blowers have commutator motors which are suitable for a 230 V, 50 Hz electrical supply. The service-life of the brushes (before re-machining the commutator) is given in the table below. The motor rotor, with bearings, should be replaced at the end of this period. Phase control and radio interference suppression are both possible.
0 300
Suction capacity V
Suction capacity V
240
300
5
270
4,5
m3/min
m3/h
m3/min
m3/h
240
4
210
3,5
180
3
150
2,5
120
2
1,5
90
1,5
1
60
1
0,5
30 0 300
APV-5333b
50 0 mbar 200 150 100 p Total pressure difference (vacuum)
0,5 APV-5334a
mbar 200 150 100 50 0 p Total pressure difference (vacuum)
Selection and ordering information Motor
Suction capacity max.
Vacuum max.
Order No.
Weight approx.
Average power consumption
Rated voltage
Frequency
Speed
Service life of brushes
W
V
Hz
rpm
h
m3/h
mbar
1100
230
50
32000 to 43200
850
184
235
1BA4 420 - 6FE01
1.6
1400
230
50
34000 to 47 000
850
206
271
1BA4 425 - 6JE03
1.7
Dimensions (mm)
PV-5331b
a
b
c
d
e
f
1BA4 420 - 6FE01
138.8
97.5
121.7
24.5
110.2
63.25
1BA4 425 - 6JE03
138.8
97.5
121.7
24.5
110.2
63.25
b a
e
Type
f
d
c
kg
Radial blower
68
elmo vacuum technology GmbH
Conversion Tables
Suction capacity
Pressure Multiplication of the value with units
With conversion factor
Results in the value with units
Multiplication of the value with units
With conversion factor
Results in the value in units
Pa
0.01
mbar
l/min
0.06
m3/h
hPa
1.0
mbar
gal/min
0.227
m3/h
kPa
10.0
mbar
ft3/min
1.699
m3/h
mm H2O
0.098
mbar
m3/h
16.667
l/min
m H2O
98.07
mbar
m3/h
4.403
gal/min
at
980.7
mbar
m3/h
0.588
ft3/min
inch H2O
2.491
mbar
PSI lpf/in2
68.948
mbar
mbar
100
Pa
mbar
10.2
mm H2O
Multiplication of the value with units
With conversion factor
Results in the value in units
mbar
10.2 · 10-3
m H2O
hp
0.746
kW
mbar
1.02 · 10-3
at
Btu/h
293.1
kW
mbar
0.4016
inch H2O
kW
1.341
hp
mbar
14.505 · 10-3
PSI lpf/in2
kW
3.41 · 10-3
Btu/h
Electrical power
Example of conversion:
Weight
250 [inch H2O] · 2.491 = 622.5 [mbar]
Multiplication of the value with units
With conversion factor
Results in the value in units
lbm
0.454
kg
kg
2.205
lbm
Multiplication of the value with units
With conversion factor
Results in the value in units
in.
25.4
mm
in.
0.0254
m
ft
305
mm
ft
0.305
m
m
39.37
in.
m
3.28
ft
The following formula is used to convert values in the unit — inch of mercury vacuum to values in the unit — mbar abs.ii: 1013 - X [inches of mercury vacuum] · 33.8 q Y [mbar abs.]
Length
Types of pressure • Absolute pressure The pressure measured from absolute zero, using ideal vacuum as the datum. The measured pressure is always greater than the reference pressure. • Total pressure difference, pressure The pressure measured above the prevailing atmospheric pressure. The datum is the prevailing atmospheric pressure and the measured pressure is always higher than the datum. • Total pressure difference, vacuum The pressure measured lower than the prevailing atmospheric pressure. The datum is the prevailing atmospheric pressure and the measured pressure is always lower than the datum.
Total pressure difference (vacuum)
Temperature conversion
Total pressure difference (gauge)
to
°F
K
°F
°C
K
°F
t [°F] = 1.8 · T [K] - 459.67
°C
°F
t [°F] = 1.8 · t [°C] + 32
T [K] =
t [°F] + 459.67 1.8
t [°C] =
t [°F] - 32 1.8
A PV-5057a
Absolute pressure
Conversion from
100% vacuum 0 mbar
elmo vacuum technology GmbH
Atmosphere Biometric pressure approx. 1013 mbar
69
General Safety Information
NOTE: The products in this catalogue are used in the • capital goods industry • consumer goods industry
and in such sectors as • agriculture • the building industry and • allied trades. This equipment has bare parts that are dangerous because they are live during operation, in some cases these are moving or rotating parts. Such parts could cause severe injury to persons and severe damage to property, for example in the event of unauthorised removal of protective covers, improper use, wrong operation or insufficient maintenance. The people in charge of safety must therefore guarantee that • only qualified personnel are allowed to work
on or around this equipment;
supplied with the equipment, and are under an obligation to systematically follow the instructions given therein; • unqualified personnel are not allowed to work on these machines or equipment or in the vicinity thereof. Qualified personnel are persons who – on account of their training, experience, instruction, knowledge of the appropriate standards, specifications, accident prevention regulations and the operating enviroment – have been authorised by those responsible for plant safety to perform the necessary work and at the same time to recognise and circumvent potential hazards. Knowledge of first aid and familiarity with the pertinent life-saving equipment are also necessary. The debarring of unqualified personnel from work on heavy-current equipment is regulated by DIN VDE 0105 or IEC 364.
variations, or to provide for every possible contingency that might arise in installation, operation or maintenance. The operating instructions therefore only contain the information necessary to enable qualified personnel (see above) to operate the machines or equipment correctly in industrial applications. In the event that the machines or equipment are intended for service outside of industry, where more exacting demands may be placed on them (such as touch protection for children), the installation work must be supplemented by further protective measures that are to be implemented by others. Where clarifications are necessary, particularly with respect to lack of product-specific detailed information, please contact the sales office concerned, quoting the type designation of the machine or equipment. It is advisable to arrange for our service centres to take charge of the necessary planning, installation, commissioning and after-sales service.
• this personnel have access at all times while
working on the equipment to the appropriate operating instructions and other documents
70
For the sake of clarity, the operating instructions supplied with the machines are not intended to cover all details of equipment
elmo vacuum technology GmbH
Conditions of Sale and Delivery, Export Regulations Small orders With small orders, the costs of handling the order exceed the value of the order. It is recommended that requirements are added together. If this is not possible, we will be obliged to charge a handling supplement of EUR 20.- for orders with a net goods value of less
than EUR 100.– to cover a proportion of our costs for order handling and invoicing.
Ordering special versions If products are orders that are different from the versions given in the catalogue, a “–Z” is to be added to the order number given in the catalogue, and the required characteristic is then also to be added in full text.
Conditions of Sale and Delivery Within Germany:
For export:
The General Conditions of Sale apply, plus the
The General Conditions of Delivery for products and services from the electrical industry and all other conditions agreed with the recipients of the price lists.
General Conditions of Delivery for electrical products and services. Prices are given in EURO ex factory, excluding packaging; this is charged at cost.
a Unless otherwise stated on the individual pages of this catalogue, we reserve the right to make changes, especially to the given values, dimensions and weights. Illustrations are not binding.
Value-added tax is not included in the prices. It will be charged at the rate valid at the time in accordance with the requirements of the law.
We also reserve the right to make price modifications and will charge the prices valid on delivery.
Export regulations According to the current provisions (09/98) of the German and US export regulations, the products listed in this catalogue do not require any export permit. Export or re-export is therefore allowed without the permission of the competent authorities unless the Order on
Trade marks
Foreign Trade lays down country-specific restrictions. The markings given on the delivery slip and invoice are the decisive criteria. An export permit obligation may arise for specific countries as a result of the intended use of the products.
All product designations are trade marks or product names of elmo vacuum technology GmbH or other companies.
elmo vacuum technology GmbH
Responsible for the technical content Lutz Kasimir elmo vacuum technology GmbH Marketing Communication
71
Only Quality Has a Future
Electronic check of the dimension accuracy of an ELMO-G impeller.
Fully automatical final check of endshields of ELMO-F and -G drives.
Technical progress and market success are inseparable from the high quality of ELMO vacuum pumps and compressors. To guarantee this high quality level, a reliable quality assurance system has been established for monitoring all phases of production from development to delivery.
This quality assurance system meets the worldwide requirements, corresponds with the relevant standards and specifications and fulfils the requirements of ISO 9001. This gives our customers the following advantages: maximum operational safety; high, consistent supply reliability; • compliance with the requirements of the European Market; • participation in national and international tenders. • •
Check of performance data and printing of the test protocol.
72
elmo vacuum technology GmbH
Your direct contact to elmo
Sales region
Address
Contact
Telephone
Fax
elmo vacuum technology GmbH A Siemens Company Humboldtstraße 59 D-90459 Nürnberg Germany
Mr. J. Müller, Dep. M BD2
[email protected]
+49 (911) 433-7773
+49 (911) 433-6935
Siemens E&A, Inc Dep. IPD/VP&C 4620 Forest Ave Norwood, OH 45212 USA
[email protected] www.siemensvpc.com/sales
+1 (513) 841-3300
+1 (513) 841-3302
Mr. Leslie J. Croyston
[email protected]
+65 845-4780
+65 845-4789
Siemens Ltd. 885, Mountain Highway Bayswater, Vic. 3153 Australia
Mr. Glenn Plymin, Dep. A&D
[email protected]
+61 (3) 9721-7542
+61 (3) 9721-7908
Siemens Vacuum Pump & Compressor Co. Ltd. No. 448, BaiYucheng ZiBo 255213 BoShan, ZiBo, ShangDong Rep. of China
Mrs. Qiulan Liu, Dep. elmo GM