Report PT Test
Short Description
Descripción: Applause_Rev01...
Description
NORCONTROL PANAMÁ, S.A. Ciudad del Saber Edificio 223 Ciudad de Panamá, Apartado Postal # 6-8648, El Dorado Tel. (507)265-4150 Fax (507)265-7471 R.U.C. 719769-1-472808 D.V.35 www.appluscorp.com
PT TESTS 1. DESCRIPTION OF WORK 1.1 Objective 1.2 Scope 1.3. Inspection Dates 1.4. Place of Inspection 1.5. Personal 2. APPLICABLE DOCUMENTS 3. EQUIPMENT 4. WORKS CARRIED OUT 5. RESULTS 6. RECOMMENDATIONS 7. CONCLUSIONS ANNEXES
Prepared by: Date / Signature Diana Gonzalez Ing. Inspector END Approved by: Date / Signature Ing. José A Tapia
Customer: SEIL PANAMA N / A Reference:
1. DESCRIPTION OF WORK
1.1 Objective Conduct non destructive testing of Penetrant Inks (PT) in twelve (12) welds of the bottom plates of the Service water tank belong to SEIL SUB-Contractor, PANAMA COLON POWER PROJECT. 1.2 Scope Inspection by non-destructive tests PT to twelve (12) welds of the bottom plates of the Service water tank belong to SEIL PANAMA SUB-Contractor, PANAMA COLON POWER PROJECT. 1.3 Inspection Dates The inspection was performed on 19/01/2017 at the site indicated by SEIL PANAMA customer. 1.4 Place of Inspection PANAMA COLON POWER PROJECT– Colón, Panamá. 1.5 Personal
Metallurgical Engineer Diana Marcela González Moreno
2. APPLICABLE DOCUMENTS The tests have been performed as specified by the inspection test procedure by UT, MT and PT APPLUS NORCONTROL and other applicable documents.
IT-MEC-003 03 Procedimiento Ensayo Mediante Ultrasonido scan A defectologia.
IT-MEC-001.03 Procedimiento Ensayo mediante Líquidos Penetrantes.
IT-MEC-002 03 Procedimiento Ensayo Mediante Partículas Magnéticas.
Asme Code Section VIII division I rules for construccion vessels. Mandatory appendix 12 Ultrasonic Examination of Welds (UT); Mandatory appendix 6 Methods for Magnetic Particle Examination (MT); Mandatory appendix 8 Methods for Liquid Penetrant Examination (PT).
Asme Code section V, Article 4.
Standard Practice for Ultrasonic Contact Examination of Weldments (ASTM E164).
Standard Test Method for Liquid Penetrant Examination (ASTM E 165-2)
(Año 2017)
Página 2 de 5
Standard Guide for Magnetic Particle Testing (ASTM E 709)
3. EQUIPMENT For the accomplishment of the works, the following equipments were used: • Penetrant Ink Kit. •Photographic camera. •Laptop. 4. WORKS CARRIED OUT
Inspection was done using Penetrant Inks to the bottom welds of the small tank FW001, FW002, FW003, FW004, FW005, FW006, FW007, FW008, FW009, FW010, FW011, FW012, in the PANAMA COLON POWER PROJECT belong to SEIL SUB-Contractor. Imagen 1. Plate temperature
Imagen 2. Clean surface
Imagen 3. Aplicación del penetrante.
Imagen 4. Aplicación del revelador.
(Año 2017)
Página 3 de 5
5. RESULTS During the inspection by Penetrating Inks, no relevant indications were found in the weld bead, good anchoring, filling and presentation were observed, and mechanical cleaning allowed a satisfactory test. The temperature control was carried out throughout the inspection procedure. 6. RECOMMENDATIONS N/A 7. CONCLUSIONS The welds inspected on the bottom plates of the tank are in accordance with the acceptance standard referenced for this non-destructive test.
(Año 2017)
Página 4 de 5
ANNEX 1: INSPECTION REPORT USING PENETRATING INKS
(Año 2017)
Página 5 de 5
REPORTE DE INSPECCIÓN ENSAYO DE LIQUIDOS PENETRANTES
ODT:
REPORTE N°:
PROCEDIMIENTO:
P&ID:
OT-
PT-
PR-END-028.03
N.A.
FECHA:
ID/TAG:
LUGAR:
SISTEMA:
19-ene-17
Bottom plate of Services water Tank
Colón - Panama
N.A.
Hoja
1 de 3
ENSAYO DE LÍQUIDOS PENETRANTES MATERIAL UTILIZADO
PENETRANTE
FABRICANTE
TIPO DE CLASIFICACIÓN
MAGNAFLUX
SKL-SP2
-
-
MAGNAFLUX
SKC-S
MAGNAFLUX
SKD-S2
EMULSIFICANTE LIMPIADOR / REMOVEDOR REVELADOR
PROCEDIMIENTO DE APLICACIÓN
LIMPIEZA
PENETRANTE
QUÍMICA
LIMPIEZA DEL PENETRANTE
VISIBLE
X
SOLVENTE
REVELADOR
X
POLVO SECO:
MECÁNICA
X
COLOREADO
AGUA
HÚMEDO NO ACUOSO:
SOLVENTE
X
FLUORECENTE
POST-EMULSIFICABLE
SOLUCION ACUOSA.
X
VARIABLES DE INSPECCIÓN
ACTIVIDAD
DURACIÓN
METODO DE APLICACIÓN
TEMPERATURA (°C)
ILUMINACIÓN
LIMPIEZA
5 Min
TIPO II METODO C
AMBIENTE
-
PENETRANTE
10 Min
TIPO II METODO C
AMBIENTE
-
LIMPIEZA
5 Min
TIPO II METODO C
AMBIENTE
-
REVELADOR
10 Min
TIPO II METODO C
AMBIENTE
-
VISTA GENERAL
RESULTADOS
REFERENCIA JUNTAS SOLDADAS
TIPO DE INDICACIÓN
FORMA
DIMENSIÓN
JUNTA FW 001 de la lamina A1
SIN INDICACIONES REELEVANTES
-
-
EVALUACIÓN CONFORME
JUNTA FW 002 de la lamina A1
SIN INDICACIONES REELEVANTES
-
-
CONFORME
JUNTA FW 003 de la lamina A1
SIN INDICACIONES REELEVANTES
-
-
CONFORME
JUNTA FW 004 de la lamina A1
SIN INDICACIONES REELEVANTES
-
-
CONFORME
JUNTA FW 005 de la lamina A1
SIN INDICACIONES REELEVANTES
-
-
CONFORME
JUNTA FW 006 de la lamina A1
SIN INDICACIONES REELEVANTES
-
-
CONFORME
JUNTA FW 007 de la lamina A1
SIN INDICACIONES REELEVANTES
-
-
CONFORME
JUNTA FW 008 de la lamina A1
SIN INDICACIONES REELEVANTES
-
-
CONFORME
JUNTA FW 009 de la lamina A1
SIN INDICACIONES REELEVANTES
-
-
CONFORME
JUNTA FW 010 de la lamina A1
SIN INDICACIONES REELEVANTES
-
-
CONFORME
JUNTA FW 011 de la lamina A1
SIN INDICACIONES REELEVANTES
-
-
CONFORME
JUNTA FW 012 de la lamina A1
SIN INDICACIONES REELEVANTES
-
-
CONFORME
CONCLUSIONES
SE EVIDENCIA POROSIDAD AGRUPADA EN LAS JUNTA # 1. Por la tecnica de líquidos no se observan indicaciones relevantes Elaboró:
Diana Marcela Gonzalez
Revisó:
Jose Tapías
Aprobó:
Certificado:
Nivel II Líquidos Penetrantes
Fecha:
23/01/2017
Fecha:
Firma:
Cargo:
FR-END-053.01 Ensayo de liquidos penetrantes
Ingeniera END Applus
Firma:
Firma:
Cargo:
Cargo:
ODT:
REPORTE N°:
PROCEDIMIENTO: PR-END-028.03
P&ID:
HOJA 2 DE 3
REGISTRO FOTOGRAFICO
Area a inspeccionar e identificación de la pieza
Foto 1. Instrumentos de medición y control. La Temperatura de la lámina a inspeccionar estuvo en un rango de 46 °C ‐ 48.2°C
Foto 4. Revisión del lote y fecha del kit de tintas penetrantes.
Foto 2. Limpieza mecanica (con grata) a la soldadura a inspeccionar. Se elimina irregularidades superficiales que puedan enmascarar indicaciones de discontinuidades inaceptables.
Foto 5. Aplicación del líquido penetrante sobre la soldadura a inspeccionar. Se deja actuar 10 minutos. Vista junta FW 001 de la lámina A1
Foto 7. Vista junta FW 003 de la lámina A1
Foto 9. Vista junta FW 006 de la lámina A1
FR-END-053.01 Ensayo de liquidos penetrantes
Foto 3. Limpieza mecanica (con grata) a la soldadura a inspeccionar. Se elimina irregularidades superficiales que puedan enmascarar indicaciones de discontinuidades inaceptables.
Foto 6. Vista junta FW 002 de la lámina A1
Foto 8. Vista junta FW 004 de la lámina A1
Foto 10. Vista junta FW 007 de la lámina A1
Foto 11. Vista junta FW 008 de la lámina A1
ODT:
REPORTE N°:
PROCEDIMIENTO: PR-END-028.03
P&ID:
HOJA 3 DE 3
REGISTRO FOTOGRAFICO
Foto 12. Vista junta FW 009 de la lámina A1
Foto 13. Vista junta FW 010 de la lámina A1
Foto 14. Vista junta FW 011 de la lámina A1
Foto 15. Vista junta FW 012 de la lámina A1
Foto 17. Aplicación del revelador. Se dejó actuar por 10 minutos monitoreando el comportamiento de las indicaciones , este procedimiento se realizó con cada uno de las juntas soldadas en la lamina A1.
Foto 16. Remoción del exceso de líquido penetrante. Aproximadamente 7 minutos en la limpieza con cleaner
Foto 18. Vista del revelador en la junta FW 001 de la lámina A1. No se observa indicaciones
FR-END-053.01 Ensayo de liquidos penetrantes
Foto 19. Vista del revelador en la junta FW 002 de la lámina A1. No se observa indicaciones
Foto 20. Vista del revelador en la junta FW 003 de la lámina A1. No se observa indicaciones
ODT:
REPORTE N°:
PROCEDIMIENTO: PR-END-028.03
P&ID:
HOJA 3 DE 3
REGISTRO FOTOGRAFICO
Foto 21. Vista del revelador en la junta FW 004 de la lamina A1. No se observa indicaciones. Debido a tanta iluminación solar no se logró una buena fotografía.
Foto 24. Vista del revelador en la junta FW 007 de la lámina A1. No se observa indicaciones
Foto 27. Vista del revelador en la junta FW 010 de la lámina A1. No se observa indicaciones.
FR-END-053.01 Ensayo de liquidos penetrantes
Foto 22. Vista del revelador en la junta FW 005 de la lamina A1. No se observa indicaciones.
Foto 25. Vista del revelador en la junta FW 008 de la lámina A1. No se observa indicaciones.
Foto 28. Vista del revelador en la junta FW 011 de la lámina A1. No se observa indicaciones.
Foto 23. Vista del revelador en la junta FW 006 de la lamina A1. No se observa indicaciones.
Foto 26. Vista del revelador en la junta FW 009 de la lámina A1. No se observa indicaciones.
Foto 29. Vista del revelador en la junta FW 012 de la lámina A1. Se observa un poro, se recomienda remover lo cual se realiza inmediatamente.
View more...