Reciprocating Pump Catalog
National Oilwell Pumps Wheatley Gaso Pumps Omega Pumps
Selecting a NOI Reciprocating Pump A reciprocating pump is a positive displacement machine, liquid discharge pressure being limited only by the strength of the structural parts. Liquid volume or capacity delivered is constant regardless of pressure, and is varied only by driver speed, speed reduction, and/or plunger/piston size changes. Determining plunger or piston rod load, calculating volumetric efficiency, and evaluating the types of devices available for pulsation control and inlet/discharge are critical in the pump selection process.
Reciprocating Pump Selection: The Basics The Fluid Understanding the characteristics of the fluid being pumped is essential to making the correct reciprocating pump selection for your application. To make the proper pump selection, you will need to know: ● What is the fluid composition (including % and type of solids present) ● What are temperatures at inlet and outlet ● What is the specific gravity of liquid at outlet and inlet pressures and temperatures. ● Are corrosives and/or abrasives present in the liquid ● What is Vapor pressure at pumping temperature ● What is the viscosity of liquid at pumping temperature The Capacity Determining the gallons per minute, barrels per hour or barrels per day required to meet the needs of the application is critical in pump selection process. The Pressure Evaluating the pressure conditions required for any pumping application will be required before the correct NOI reciprocating pump can be identified. To ensure correct selection, you will need to know. ● What is the required liquid pressure at discharge ● What is the required liquid pressure at inlet/suction (NPSHR) Other factors can play a significant role in pump selection: ● Electrical hazards ● Flange rating required ● Preferred/specified metallurgy of major parts ● Driver type ● Space limitation/constraints ● Site ambient temperature range ● Indoor/outdoor application ● Storage/future use considerations The following conversion charts and engineering data will assist you determining the essential items identified above. The comprehensive evaluation of these items will ensure that you are utilizing the best available NOI reciprocating pump technology for your application. For specific recommendations or engineering assistance, please consult your NOI sales representative.
Formulas and factors to help pick the right pump. It is easy to select the right multiplex pump to best meet your anticipated volume and pressure requirements. ● First calculate the hydraulic horsepower. ● Then determine the input horsepower required. Use input horsepower to identify the smallest pump suitable for the application or the combination of pumps needed to meet the total requirement. ● Further selection of plunger size and operating speed will tailor the pump to your volume and discharge pressure requirements. Helpful sizing formulas hyd. hp = gpm x psi x .00058 hyd. hp = bbl/day x psi x .000017 hyd. hp = gpm x psi/1714 hyd. hp = bbl/day x psi/58,800 input hp = hyd. hp/mech. eff. bbl/day = gpm x 34.285 bbl/day = m3/d x 6.2897 bbl/day gpm = BDP/34.285 gpm = bbl/day x .02916 feet water = psi x 2.31 psi = feet water x .433 psi = kg/cm2 x 14.223 m/d = bbl/day 6.2897 kg/cm2 = Psi x .0703 mm = inches x 25.4 kg = pounds x .45359 liter = gallons x 3.785
Application Plunger pumps for fluid injection projects. The simplest plunger pump installation is in reality a complex hydraulic system. While it is not possible to anticipate all of the operational peculiarities of a pump installation, it is to the operator’s advantage to consider certain well-known design factors and incorporate these factors into the station arrangement. The following will help determine these factors. Suction pressure Plunger pumps have certain characteristics which must be considered in designing the pump inlet system to assure satisfactory performance. A positive inlet pressure is required by a plunger pump while running to enable it to fill on each stroke. This pressure is referred to as Net Positive Inlet Pressure (NPIP) and is measured on the absolute pressure scale. Fig. 1 shows that absolute pressure is the sum of local barometric pressure plus gauge pressure. NPIP is affected by many factors: pump speed, plunger diameter, valve type and through area, valve spring load, temperature, and vapor pressure of liquid being pumped as well as local uncorrected barometric pressure. A conservative approach to designing a pump inlet system is to assume that any plunger pump in water injection service requires a minimum NPIP of 15 psia, above vapor pressure, while running. Obviously any NPIP above this minimum will result in improved fluid end performance and provides insurance against unpredictable changes in operating conditions such as an increase in water temperature, lower tank water level, gas entrainment, etc.
Major positive and negative pressures in a pump inlet system: Positive A. Liquid Level above Pump Inlet (psi) = (feet x .433) B. Atmospheric Pressure (psia) = Local uncorrected barometric reading (inches of mercury x .4912) C. Gas Blanket Pressure (psi) (usually of small magnitude and can be ignored in NPIP calculations) Negative D. Vapor Pressure of Fluid (psia) E. Friction in Piping (psi) F. Acceleration Head (psi) Additional information concerning these factors: A. Supply Tank Elevation The supply tank should be located at an elevation as high as possible with relation to the pump suction, taking advantage of the natural terrain. Since pipe friction is usually of a low order, it is sometimes advantageous to disregard the accepted rule “to make the inlet line as short as possible” and increase line length in order to gain additional tank elevation. Before locating the pump and supply tank, make calculations to determine if an elevated tank with a long inlet line or a tank at a lower elevation with a short inlet line provides the greater NPIP. B. Atmospheric Pressure This is the true local uncorrected barometric pressure at the altitude of pump location expressed in psia. Refer to Figure 1. Note: Barometric pressure as reported by the weather bureau is normally corrected to sea level conditions. The uncorrected reading must be used. C. Gas Blanket Pressure A gas blanket on the supply tank adds additional positive pressure to the inlet system. Furthermore, a gas blanket of a few ounces prevents absorption of oxygen by the water and reduces corrosion in the pumps and piping. D. Vapor Pressure This is the absolute pressure at which the liquid will change to vapor at a given temperature. Vapor pressure becomes most critical when pumping fluid hydrocarbons; e.g., propane, crude oil, butane, L.N.G., etc., or water at elevated temperatures. Table on page 5 reflects the vapor pressure/temperature relationship of water. E. Friction in Piping The inlet line should be as short as practical with a minimum of bends and fittings. A single inlet line between pump and tank or header should be adequate for most installations. When more than one pump is drawing from the same tank, it is best to run individual inlet lines from each pump to the tank. If bends or elbows are necessary in the line, they should be of long radius. F. Acceleration Pressure This is the theoretical inertia effect of the fluid mass in the inlet line and is probably the least understood factor affecting pump performance. In effect, it is the pressure necessary to accelerate the fluid at the beginning of each plunger stroke. The acceleration pressure may be quite large in high speed reciprocating pumps with long inlet lines. It is a function of the volume of fluid in the inlet line, the pump speed, number of plungers, and pump displacement. The pressure required to accelerate cold water without cavitation may be calculated with the formula:
Pac = KNLQ D s2 Where: Pac = Acceleration Pressure (psia) Factor for type of pump Duplex Double Acting Pump K = .000451 Triplex Single Acting Pump K = .000259 Quintuplex Single Acting Pump K = .000157 N = Pump Speed (rpm) L = Inlet Line Length (Ft.) Q = Pump Discharge (gpm) Ds =Inlet Line Diameter (inches) From the above calculation it will be readily seen that large diameter inlet pipe is important. Tests have demonstrated that the acceleration pressure requirement can be practically canceled by locating a suction stabilizer in the inlet line as close as possible to the pump intake. Therefore, the use of suction stabilizers on each pump is strongly recommended. Typical Inlet System (Open Type) Where: NPIP Required (Net Positive Inlet Pressure) = That absolute pressure in psia, above vapor pressure, as determined by test, required to fill the pump cylinders sufficiently so that no more than a 3% drop in capacity from maximum is achieved (15.0 psia assumed in these examples). NPIP Available = That pressure in psia of liquid being pumped existing at the pump inlet. Pa = Atmospheric pressure in psia due to altitude. (Three elevations - 0, 3000 and 5000 feet are used in our examples). Pv = Vapor pressure in psia of liquid being pumped. (1.7 psia in these examples). Pf = Pressure drop in psi caused by friction in piping and fittings. (.1 psi in these examples). H = Height of liquid above pump inlet measured in feet. P1 = Pressure in psig at pump inlet. P2 = Pressure in psig at tank outlet. To determine H (minimum height of liquid above pump inlet) solve the following: H(ft) = (NPIP Req’d. + Pv + Pf - Pa) x 2.3 P2(psig) = H x .443 P1(psig) = P2 - Pf or P1(psia) = P1(psig)+ Pa(psia) It will be seen that as the barometric pressure decreases, the level in the supply tank must be increased to provide the same absolute NPIP at the pump inlet. If the vapor pressure or pressure loss increase, the supply tank level must be increased proportionally to maintain the NPIP required. The above calculations provide minimum NPIP; a good operating practice is to provide an additional 5 to 10 feet of head for contingencies. Calculation of Inlet System To provide sufficient Net Positive Inlet Pressure (NPIP) it is necessary to determine the minimum height of liquid required in the supply tank. The interrelationship of vapor pressure of the liquid being pumped, the atmospheric pressure and the liquid level above the pump inlet is shown in the examples (Fig. 3).
Low Inlet Pressure Where sufficient NPIP is not available, increased inlet pressure may be obtained by the use of an inlet charging centrifugal pump. Total horsepower requirements are not increased by the use of the charging pump as the power input to he main pump will be reduced by the power requirement of the charging pump. High Inlet Pressure In single acting pumps high inlet pressure actually increases the bearing loads and for this reason correction must be made to plunger size selection if the inlet pressure is more than 5% of the discharge pressure. For triplex pumps the plunger size should be determined in the basis of an artificial discharge pressure (Px) equal to the actual Discharge pressure (Pd) plus one-half the actual inlet pressure (Pi). Px=Pd+1/z Pi (for single acting triplex pumps)
Recommended Auxiliary Equipment Suction Stabilizer As previously pointed out the use of a suction stabilizer on each pump is recommended. A simple vertical chamber with a closed top, water level gauge and air charging connection will perform satisfactorily as a suction stabilizer if properly pressurized with an air or gas cushion on top of the fluid. Water absorbs air and gasses; therefore, this type of chamber requires regular attention. Commercial stabilizers, equipped with a rubber diaphragm separating the air from the fluid, are available and can be charged to a predetermined pressure with air or nitrogen. This charge will normally be retained for a long period of time.
For quintuplex pumps the artificial pressure should be the actual discharge pressure plus two-thirds the actual inlet pressure. Px = Pd + 2/3 Pi (for single acting quintuplex pumps)
Discharge Pulsation Dampeners A pulsation dampener should be installed on each pump as close to the fluid end as possible.
The work performed by the pump, however, is calculated in the usual manner using the actual discharge pressure less the pump inlet pressure.
All positive displacement reciprocating pumps discharge fluid in a pulsating manner. The harmonic relationship between the pump speed, the piping system and other pumps in the system may cause pulsations to be amplified and result in transient pressure peaks far in excess of the average discharge pressure. These peaks are not always obvious and seldom will be indicated on pressure gauges.
Inlet and Discharge Piping Inlet Piping Line The line from the supply tank to the pump should be as short and direct as practical and of sufficient diameter to limit the fluid velocity to 1 to 2 feet/second. It should be free of any restrictions and all fittings should be full opening type with low resistance to the fluid flow. Discharge Piping Line The discharge line must not be smaller than the discharge connection at the pump; it should be of a diameter sufficient to permit a maximum fluid velocity of not more than 12 feet/second. This line should be streamlined through gradual turns with friction not greater than those caused by 45 deg. long radius elbows. Do not install any bend directly adjacent to the pump discharge.
The pump may sound satisfactory with little or no audible fluid knock but, such pressure peaks subject the pump and piping system to excessively high stresses. Many tests have shown that a pulsation dampener minimizes these pressure peaks and contributes to longer pump and valve life. The need for pulsation dampeners is increased where multiple pump installations are involved. When two or more pumps are discharging into a common header, the normal pressure peaks of each pump may occur simultaneously with the result that the pressure peaks for the system will be considerably higher than for a single pump.
Safety Devices By-Pass Line A by-pass valve and by-pass return line to the supply tank (not inlet line) are recommended for all installations. This will permit loadless starting and facilitate checking the pump and prime mover. Relief Valves A relief valve must be mounted on the discharge line as close to the pump as possible. No other valve should be interposed between the pump and relief valve. The relief valve must have adequate relieving capacity and be set no higher than 1.25 times the rated plunger working pressure. Relief discharge should be piped back to the supply tank (not the inlet line). Caution: Be certain that all pipe, pipe fittings, hose, etc., in the discharge line have working pressure ratings equal to or greater than the maximum pressure rating of the pump fluid end. Warning: Provide a means to prevent materials that may have been introduced into the discharge system (rubber balls, steel balls, etc.) from entering the discharge manifold on the pump or blocking the entrance to the pressure relief valve.
Low Fluid Level Controls Low fluid level shut-down controls should be provided on all installations to protect the pump from operations with insufficient fluid to fill the pump. Operations under starved suction conditions will result in severe knocking and high shock pressures within the fluid end. The low fluid level sensor should be located on the tank to assure the minimum NPIP at the pump inlet as described in “Calculation on Inlet System” on the previous page. Low Oil Pressure Low Oil Pressure or low oil level shut-down is strongly recommended to safeguard the pump power end against lubrication failure. Low Discharge Pressure Shut-down Low Discharge Pressure Shut-down is recommended as a protection against property damage due to discharge line failure. High Discharge Pressure Shut-down High Discharge Pressure Shut-down is recommended as extra insurance against pump damage in the event of relief valve malfunction.
National-Oilwell Pump Nomenclature 100 T – 4 L Rated Input Horsepower Single-Acting Plunger Type
Fluid End Pressure Ratings
“S”
Simplex
“XL”
“D”
Duplex
“L”
Extra Low Pressure Low Pressure
“T”
Triplex
“LS”
Low Pressure Special Rating
“Q”
Quintuplex
“M”
Medium Pressure
“MS” Medium Pressure Special Rating “H”
Nominal Stroke Length
High Pressure
Quick Reference Pump Selection Single-Acting, Continuous Duty Pumps Pump Model No. Rated Horsepower 2
5
11
22
30 31 32*
55
59
60
80
100
100
103
110
125
130
133
163
165
184
200
202
NEW
OLD
2S-1L 2S-1M 2S-1H 5S-2L 5S-2M 5S-2H 11D-2L 11D-2M 11D-2H 22T-2L 22T-2M 22T-2H 30T-2L 30T-2H 31Q-2L 32T-2L 32T-2M 32T-2H 55T-3L 55T-3SC 55T-3LS 55T-3M 55T-3MS 55T-3H 59T-3L 59T-3M 59T-3MS 59T-3H 60T-3L 60T-3M 60T-3H 80T-3L 80T-3M 80T-3H 100T-4L 100T-4M 100T-4H 101T-4L 101T-4M 101T-4H 103Q-3L 103Q-3M 103Q-3MS 103Q-3H 110Q-3L 110Q-3M 110Q-3MS 110Q-3H 125T-4L 125T-4M 125T-4H 130T-4L 130T-4M 130T-4H 133T-4L 133T-4M 133T-4H 163Q-4L 163Q-4M 163Q-4H 165T-5L 165T-5M 165T-5H 184T-7XL 184T-7L 184T-7M 184T-7H 200T-5L 200T-5M 200T-5H 202T-6L 202T-6M
P50BLS P50B P50BH P50ALS P50A P50H P100ALS P100A P100H T225LS T225M T225H J-30-L J-30-H 5P200A T225LS T225M T225H 3364-7 3365-5SC 3364-6 3364-3 3364-2 3364-1 T365AL T365AM T365MS T365H J-60-L J-60-M J-60-H 80T-3L 80T-3M 80T-3H J-100-L J-100-M J-100-H T100-4 T100-3 T100-2 Q3115AL Q3115AM Q3115MS Q3115H HP125AL HP125AM HP125MS HP125H A344-H A334-H A324-H 130T-4L 130T-4M 130T-4H T140-4 T140-3 T140-2 HP165AL HP165AM HP165MS J-165-L J-165-M J-165-H HP250XL HP250BL HP250BM HP250BH J-200-L J-200-M J-200-H A346-H A336-H
Gallons Per Minute (USGPM) 4.80 3.60 1.20 10.41 7.97 2.60 23.80 18.24 5.96 42.70 32.70 10.70 51.65 22.95 57.40 42.69 32.68 10.67 95.62 77.46 95.62 46.86 46.86 23.91 134.90 93.71 33.74 14.99 137.7 61.2 28.95 174.3 61.2 28.9 209.1 82.9 56.2 209.1 114.7 48.5 232.9 161.8 58.2 25.9 235.6 163.6 58.9 26.2 293.8 165.2 92.9 241.3 103.6 56.2 209.1 114.7 48.5 339.8 186.5 78.8 326.4 154.3 81.6 636.7 347.9 203.4 87.0 326.4 154.3 81.6 353.7 176.3
Maximum Displacement Liters / Sec Barrels Per Day Cubic Meters (l/s) (BPD) Per Hour (m3/hr) 0.30 164 1.08 0.23 125 0.83 0.08 41 0.27 0.66 357 2.36 0.50 274 1.81 0.16 90 0.59 1.50 816 5.40 1.15 626 4.14 0.38 205 1.35 2.69 1,464 9.69 2.06 1,121 7.42 0.67 366 2.42 3.26 1,771 11.73 1.45 787 5.21 3.62 1,968 13.04 2.69 1,464 9.69 2.06 1,121 7.42 0.67 366 2.42 6.03 3,279 21.72 4.89 2,656 17.59 6.03 3,279 21.72 2.96 1,607 10.64 2.96 1,607 10.64 1.51 820 5.43 8.51 4,627 30.65 5.91 3,213 21.28 2.13 1,157 7.66 0.95 515 3.41 8.69 4,722 31.27 3.86 2,099 13.90 1.82 992 6.57 11.00 5,976 39.58 3.86 2,099 13.90 1.82 992 6.57 13.19 7,171 47.49 5.23 2,843 18.83 3.55 1,928 12.77 13.2 7,171 47.5 7.2 3,935 26.1 3.1 1,663 11.0 14.70 7,987 52.9 10.21 5,547 36.7 3.67 1,997 13.2 1.63 888 5.9 14.9 8,079 53.5 10.3 5,610 37.2 3.7 2,020 13.4 1.7 898 5.9 18.5 10,072 66.7 10.4 5,666 37.5 5.9 3,187 21.1 15.2 8,272 54.8 6.5 3,551 23.5 3.5 1,928 12.8 13.2 7,171 47.5 7.2 3,935 26.1 3.1 1,663 11.0 21.4 11,652 77.2 11.8 6,394 42.3 5.0 2,702 17.9 20.6 11,191 74.1 9.7 5,290 35.0 5.1 2,798 18.5 40.2 21,832 144.6 21.9 11,927 79.0 12.8 6,975 46.2 5.5 2,982 19.7 20.6 11,191 74.1 9.7 5,290 35.0 5.1 2,798 18.5 22.3 12,127 80.3 11.1 6,045 40.0
Maximum Pressure Pounds Per Kilopascals Square Inch (kPa) (psi) 1,149 7,920 2,042 14,081 4,595 31,681 1,149 7,920 2,042 14,081 4,595 31,681 1,149 7,920 2,042 14,081 4,595 31,681 1,443 9,949 2,565 17,688 4,660 32,130 2,000 13,790 5,000 34,474 2,042 14,081 2,037 14,046 2,050 14,134 4,600 31,716 1,391 9,591 1,817 12,527 1,480 10,204 3,561 24,552 2,473 17,050 3,300 22,753 970 6,686 2,295 15,825 4,789 33,017 10,000 68,948 1,500 10,342 3,200 22,063 5,000 34,474 2,017 13,906 4,267 29,420 5,161 35,584 1,659 11,436 3,180 21,925 5,000 34,474 1,220 8,408 2,744 18,919 5,378 37,081 970 6,686 2,295 15,825 4,789 33,017 10,000 68,948 1,037 7,149 2,454 16,922 5,121 35,306 10,000 68,948 1,500 10,342 3,180 21,925 5,000 34,474 1,750 12,065 3,111 21,450 5,000 34,474 1,440 9,929 3,600 24,821 6,000 41,369 1,220 8,408 2,744 18,919 5,378 37,081 1,650 11,376 3,120 21,512 5,000 34,474 728 5,020 1,204 8,299 2,912 20,081 6,000 41,369 1,680 11,583 3,349 23,097 5,000 34,474 1,500 10,342 3,180 21,925
Type
Simplex
Simplex
Duplex
Triplex
Triplex Quintuplex Triplex
Triplex
Triplex
Triplex
Triplex
Triplex
Triplex
Quintuplex
Quintuplex
Triplex
Triplex
Triplex
Quintuplex
Triplex
Triplex
Triplex
Triplex
Single-Acting, Continuous Duty Pumps (continued) Pump Model No. Rated Horsepower 217
250
267 300
308
350
430
543
622
625
750 1069
NEW
OLD
217Q-4L 217Q-4M 217Q-4H 250T-5L 250T-5M 250T-5H 267Q-6L 267Q-6M 300Q-5L 300Q-5M 300Q-5H 308T-7XL 308T-7L 308T-7M 308T-7H 350Q-5L 350Q-5M 350Q-5H 430T-7L 430T-7M 430T-7H 543Q-7XL 543Q-7L 543Q-7M 543Q-7H 622T-8XL 622T-8L 622T-8M 622T-8MS 625Q-7L 625Q-7M 625Q-7H D-750L C-1000
HP200AL HP200AM HP200MS 250T-5L 250T-5M 250T-5H A-546 A-536 J-275-L J-275-M J-275-H HP360XL HP360AL HP360AM HP360H Q350-4 Q350-3 Q350-2
HP600XL HP600AL HP600AM HP600H T600-7 T600-5 T600-4 T600-3 J-625-L J-625-M J-625-H D-750L C-1000
Gallons Per Minute (USGPM) 339.8 186.5 78.8 368.5 215.5 103.3 663.3 330.5 544.0 257.1 136.0 636.7 347.9 203.4 87.0 489.6 323.2 154.9 535.5 301.2 192.8 1121.3 612.6 358.2 153.1 1039.6 530.4 339.5 190.9 850.8 544.5 306.3 560 929
Maximum Displacement Liters / Sec Barrels Per Day Cubic Meters (l/s) (BPD) Per hour (m3/hr) 21.4 11,652 77.2 11.8 6,394 42.3 5.0 2,702 17.9 23.2 12,634 83.7 13.6 7,388 48.9 6.5 3,541 23.5 41.8 22,741 150.7 20.9 11,331 75.1 34.3 18,651 123.6 16.2 8,816 58.4 8.6 4,663 30.9 40.2 21,832 144.6 21.9 11,927 79.0 12.8 6,975 46.2 5.5 2,982 19.7 30.9 16,787 111.2 20.4 11,082 73.4 9.8 5,312 35.2 33.8 18,360 121.6 19.0 10,328 68.4 12.2 6,610 43.8 70.7 38,445 254.6 38.6 21,003 139.1 22.6 12,283 81.4 9.7 5,251 34.8 65.6 35,643 236.1 33.5 18,186 120.5 21.4 11,639 77.1 12.0 6,547 43.4 53.7 29,172 193.2 34.4 18,671 123.7 19.3 10,502 69.6 35.3 19,200 127.2 58.6 31,851 211.0
Maximum Pressure Pounds Per Kilopascals Square Inch (kPa) (psi) 1,440 9,929 3,600 24,821 6,000 41,369 1,544 10,646 3,026 20,865 5,000 34,474 1,420 9,791 3,180 21,925 1,650 11,376 3,000 20,684 5,000 34,474 1,220 8,410 2,169 14,952 3,600 24,821 8,000 55,158 1,670 11,511 3,483 24,017 6,000 41,369 1,550 10,687 3,150 21,719 5,000 34,474 1,220 8,410 2,169 14,952 3,600 24,821 8,000 55,158 1,640 11,307 2,502 17,254 4,279 29,505 7,232 49,863 1,550 10,686 3,150 21,719 5,000 34,474 5,000 34,474 3,705 25,545
Type
Quintuplex
Triplex
Quintuplex Quintuplex
Triplex
Quintuplex
Triplex
Quintuplex
Triplex
Quintuplex
Triplex - Piston Triplex
Double-Acting, Continuous Duty Piston Pumps Rated Horsepower 12 33 74 104 127 130 250 258
Pump Model No. 535 545 1847-A 1550 1654 1757 1759 2651 2652
Gallons Per Minute (USGPM) 69.6 117 160 281.7 233.8 336.8 637.2 391.9 702.3
Maximum Displacement Liters / Sec Barrels Per Day (l/s) (BPD) 4.4 7.4 10.1 17.8 14.7 21.2 40.2 24.7 44.3
2,387 4,012 5,487 9,658 8,016 11,547 21,849 13,434 24,079
Cubic Meters Per Hour (m3/hr) 15.8 26.6 36.3 64.0 53.1 76.5 144.7 89.0 159.5
Maximum Pressure Pounds Per Kilopascals Square Inch (kPa) (psi) 796 5,487 509 3,509 990 6,826 1,440 9,929 1,800 12,411 1,750 12,066 1,042 7,184 1,760 12,135 1,125 7,757
Type
Duplex Duplex Duplex Duplex Duplex Duplex Duplex Duplex
Single-Acting, Intermittent Duty Pumps (1) Rated Horsepower 185 340 350 400 500 600 1300 2250
Pump Model No. JWS-185 JWS-340 W-350 JWS-400 W-500 W-600-S W-1300 W-2250
Maximum Displacement at Minimum Pressure Gallons Per Liters / Sec Minimum Minute (l/s) Pressure (USGPM) PSI (kPa) 367 23.2 780 (5378) 367 23.2 1,430 (9860) 689 43.5 741 (5109) 618 39.0 1,004 (6923) 689 43.5 1,058 (7295) 558 35.2 1,660 (11445) 1,515 95.6 1,250 (8619) 1,515 95.6 2,164 (14920)
Maximum Displacement at Maximum Pressure Gallons Per Liters / Sec Maximum Minute (l/s) Pressure (USGPM) PSI (kPa) 20 1.3 10000 (68,950) 39 2.5 10000 (68,950) 12 .8 25451 (175,485) 63 4.0 10000 (68,950) 16 1.0 25096 (173,037) 19 1.2 20372 (140,460) 115 7.3 165121 (113,850) 131 8.3 19894 (137,164)
Type
Piston or Plunger Piston or Plunger Plunger Piston or Plunger Plunger Plunger Plunger Plunger
(1) Applications at pressures above 15,000 PSIG must be approved by National Oilwell Engineering Department • The maximum displacement (volume) values listed assume 100% volumetric efficiency. Actual "in service" displacement (volume) will vary depending on the inlet piping and the fluid being pumped. • The rated horsepower listed includes allowances for mechanical efficiencies and is the maximum horsepower allowed for the pump model. • An auxiliary lubrication system may be required for operating speeds below 200 RPM. Please consult your Sales and Service location for details. • Pumps will not produce the maximum displacement listed at the maximum pressure listed. Consult our Sales & Service location for details.
2S-1 Simplex Plunger Pump Specifications 7.13
6.50 C 3.25
8.44
ÿ.75 TYP 3 PLACES 1.500 1.499
ÿ
.375 x .188 KEYWAY 2.813 LONG
7.03
F A
B 7.06
Pump Size: maximum plunger size x stroke length, in.(mm) 2.000 x 1.000 (50.8 x 25.4) Rated BPH (kW) at 350 RPM 2.5 (1.9) Rated plunger load, pounds (kg) 2030 (921) Maximum discharge pressure: psi (kPa) “L” model: 1149 (7920) “M” model: 2042 (14081) “H” model: 4595 (31681) Crankshaft extension: Diameter, in.(mm): 1.500 (38.1) Length, in.(mm): 3.375 (85.73) Keyway width x depth, in.(mm): 3/8 x 3/16 (9.53 x 4.76) Maximum recommended sheave diameter, in.(mm): 25 (635) For larger sizes: Contact Customer Service Oil Capacity, gallons (L) Crankcase: 1/2 (1.89) Weight, pump only on wood shipping skids, pounds (kg): 219 (99) Weight varies with pump model Standard Materials for Fluid Ends: “L” & “M” models Cast Ductile Iron, Cast 316 Stainless Steel Cast Nickel-Aluminum-Bronze Plate Carbon Steel “H” model Forged/Plate Carbon Steel Forged 15-5 Stainless Steel
.63 11.88 2.75 5.75
13.75 D E
Pump Model 2S-1L 2S-1M 2S-1H
Flange Connections Discharge Connection Sizes Suction Connection Sizes 1 (25.4)-11 1/2 FNPT 2 (50.8)-11 1/2 FNPT 1 (25.4)-11 1/2 FNPT 2 (50.8)-11 1/2 FNPT 3/4 (19.05)-14 NPT 1 1/4 (31.75)-11 1/2 THDS
A 3 1/8 3 1/8 3 3/4
Dimensions (Inches) B C D E 4 7/8 3 1/2 20 3/8 29 9/16 4 7/8 3 1/2 20 3/8 29 9/16 4 1/4 5 1/2 20 31 5/16
F 5 15/16 5 15/16 7 1/8
2S-1 Simplex Plunger Pump Performance Data PUMP
2S-1L (P50BLS)
2S-1M (P50B)
2S-1H
PUMP
2S-1L (P50BLS)
2S-1M (P50B)
2S-1H
English Units Plunger Plunger BPD Dia. Area per In. Sq. In. RPM 2.000 3.1416 0.4663 1.875 2.7612 0.4098 1.750 2.4053 0.3570 1.625 2.0739 0.3078 1.500 1.7671 0.2623 1.750 2.4053 0.3570 1.625 2.0739 0.3078 1.500 1.7671 0.2623 1.375 1.4849 0.2204 1.250 1.2272 0.1821 1.125 0.9940 0.1475 1.000 0.7854 0.1166 0.875 0.6013 0.0892 0.750 0.4418 0.0656 Brake Horsepower Required
GPM per RPM 0.0136 0.0120 0.0104 0.0090 0.0076 0.0104 0.0090 0.0076 0.0064 0.0053 0.0043 0.0034 0.0026 0.0019
Metric Units Plunger Plunger Dia. Area mm cm2 51 20.268 48 17.814 44 15.518 41 13.380 38 11.401 44 15.518 41 13.380 38 11.401 35 9.580 32 7.917 29 6.413 25 5.067 22 3.879 19 2.850 Kilowatts Required
L/Sec. per RPM 0.0009 0.0008 0.0007 0.0006 0.0005 0.0007 0.0006 0.0005 0.0004 0.0003 0.0003 0.0002 0.0002 0.0001
M3/Hr per RPM 0.0031 0.0027 0.0024 0.0020 0.0017 0.0024 0.0020 0.0017 0.0015 0.0012 0.0010 0.0008 0.0006 0.0004
50 RPM Max. Press. PSI 646 735 844 979 1149 844 979 1149 1367 1654 2042 2585 3376 4595
BPD 24 21 18 16 14 18 16 14 12 10 8 6 5 4
GPM 0.7 0.6 0.5 0.4 0.4 0.5 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0.4
150 RPM
BPD 70 62 54 47 40 54 47 40 34 28 23 18 14 10
200 RPM
GPM 2.0 1.8 1.6 1.3 1.1 1.6 1.3 1.1 1.0 0.8 0.6 0.5 0.4 0.3 1.1
BPD 94 82 72 62 53 72 62 53 45 37 30 24 18 14
GPM 2.7 2.4 2.1 1.8 1.5 2.1 1.8 1.5 1.3 1.1 0.9 0.7 0.5 0.4
250 RPM
BPD 117 103 90 77 66 90 77 66 56 46 37 30 23 17
2.0
50 RPM 150 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 4455 0.15 0.04 0.46 0.13 5069 0.14 0.04 0.41 0.11 5819 0.12 0.03 0.35 0.10 6749 0.10 0.03 0.31 0.08 7920 0.09 0.02 0.26 0.07 5819 0.12 0.03 0.35 0.10 6749 0.10 0.03 0.31 0.08 7920 0.09 0.02 0.26 0.07 9426 0.07 0.02 0.22 0.06 11405 0.06 0.02 0.18 0.05 14081 0.05 0.01 0.15 0.04 17821 0.04 0.01 0.12 0.03 23276 0.03 0.01 0.09 0.02 31681 0.02 0.01 0.07 0.02 0.3 0.8
200 RPM
M3/Hr 0.62 0.54 0.47 0.41 0.35 0.47 0.41 0.35 0.29 0.24 0.20 0.15 0.12 0.09
L/Sec. 0.17 0.15 0.13 0.11 0.10 0.13 0.11 0.10 0.08 0.07 0.05 0.04 0.03 0.02 1.5
GPM 3.4 3.0 2.6 2.2 1.9 2.6 2.2 1.9 1.6 1.3 1.1 0.8 0.7 0.5 1.8
250 RPM
M3/Hr 0.77 0.68 0.59 0.51 0.43 0.59 0.51 0.43 0.36 0.30 0.24 0.19 0.15 0.11
300 RPM
BPD 140 123 108 93 79 108 93 79 67 55 45 35 27 20
GPM 4.1 3.6 3.1 2.7 2.3 3.1 2.7 2.3 1.9 1.6 1.3 1.0 0.8 0.6
350 RPM
BPD 164 144 125 108 92 125 108 92 78 64 52 41 32 23
GPM 4.8 4.2 3.6 3.1 2.7 3.6 3.1 2.7 2.2 1.9 1.5 1.2 0.9 0.7
2.1
2.5
300 RPM
350 RPM
L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. 0.21 0.93 0.26 1.08 0.30 0.19 0.81 0.23 0.95 0.26 0.16 0.71 0.20 0.83 0.23 0.14 0.61 0.17 0.71 0.20 0.12 0.52 0.14 0.61 0.17 0.16 0.71 0.20 0.83 0.23 0.14 0.61 0.17 0.71 0.20 0.12 0.52 0.14 0.61 0.17 0.10 0.44 0.12 0.51 0.14 0.08 0.36 0.10 0.42 0.12 0.07 0.29 0.08 0.34 0.10 0.05 0.23 0.06 0.27 0.08 0.04 0.18 0.05 0.21 0.06 0.03 0.13 0.04 0.15 0.04 1.3 1.6 1.9
Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 72% Mechanical Efficiency. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
5S-2 Simplex Plunger Pump Specifications 7.13
6.50 C
C
3.25
8.44 ÿ.75 TYP 3 PLACES 1.500 ÿ1.499
.38 X .18 X 2.81 LG KEYWAY "5S-2H" ONLY
7.03
F
F
A
A
B
B
7.06
.63 11.88 2.75 5.75
13.75 D
D E
Pump Model 5S-2L 5S-2M 5S-2H
Flange Connections Discharge Connection Sizes Suction Connection Sizes 1 (25.4)-11 1/2 FNPT 2 (50.8)-11 1/2 FNPT 1 (25.4)-11 1/2 FNPT 2 (50.8)-11 1/2 FNPT 3/4 (19.05)-14 NPT 1 1/4 (31.75)-11 1/2 THDS
E
A 3 1/8 3 1/8 3 3/4
Pump Size: maximum plunger size x stroke length, in.(mm) 2.000 x 2.188 (50.8 x 55.56) Rated BHP (kW) at 350 RPM 5.5 (4.1) Rated plunger load, pounds (kg) 2030 (921) Maximum discharge pressure: psi (kPa) “L” model: 1149 (7920) ”M” model: 2042 (14081) ”H” model: 4595 (31681) Crankshaft extension: in.(mm) Diameter, in.(mm): 1.500 (38.1) Length, in.(mm): 3.375 (85.73) Keyway width x depth, in.(mm): 3/8 x 3/16 (9.53 x 4.76) Maximum recommended sheave diameter, in.(mm): 25 (635) For larger sizes: Contact Factory Oil Capacity, gallons (L) Crankcase: 1/2 (1.89) Weight, pump only on wood shipping skids, pounds (kg): 218 (99.1) Weight varies with pump model Standard Materials for Fluid Ends: ”L” & ”M” models Cast Ductile Iron Cast Nickel-Aluminum-Bronze Cast 316 Stainless Steel Plate Carbon Steel ”H” model Forged Carbon Steel Forged 15-5 Stainless Steel
Dimensions (Inches) B C D E 4 7/8 3 1/2 20 3/8 29 9/16 4 7/8 3 1/2 20 3/8 29 9/16 4 1/4 5 1/2 20 31 5/16
F 5 15/16 5 15/16 7 1/8
5S-2 Simplex Plunger Pump Performance Data PUMP
5S-2L (P50ALS)
5S-2M (P50A)
5S-2H (P50H)
PUMP
5S-2L (P50ALS)
5S-2M (P50A)
5S-2H (P50H)
English Units Plunger Plunger BPD Dia. Area per In. Sq. In. RPM 2.000 3.1416 1.0200 1.875 2.7612 0.8965 1.750 2.4053 0.7809 1.625 2.0739 0.6734 1.500 1.7671 0.5737 1.750 2.4053 0.7809 1.625 2.0739 0.6734 1.500 1.7671 0.5737 1.375 1.4849 0.4821 1.250 1.2272 0.3984 1.125 0.9940 0.3227 1.000 0.7854 0.2550 0.875 0.6013 0.1952 0.750 0.4418 0.1434 Brake Horsepower Required
GPM per RPM 0.0297 0.0261 0.0228 0.0196 0.0167 0.0228 0.0196 0.0167 0.0141 0.0116 0.0094 0.0074 0.0057 0.0042
Metric Units Plunger Plunger Dia. Area mm cm2 51 20.268 48 17.814 44 15.518 41 13.380 38 11.401 44 15.518 41 13.380 38 11.401 35 9.580 32 7.917 29 6.413 25 5.067 22 3.879 19 2.850 Kilowatts Required
L/Sec. per RPM 0.0019 0.0016 0.0014 0.0012 0.0011 0.0014 0.0012 0.0011 0.0009 0.0007 0.0006 0.0005 0.0004 0.0003
M3/Hr per RPM 0.0068 0.0059 0.0052 0.0045 0.0038 0.0052 0.0045 0.0038 0.0032 0.0026 0.0021 0.0017 0.0013 0.0010
50 RPM Max. Press. PSI 646 735 844 979 1149 844 979 1149 1367 1654 2042 2585 3376 4595
BPD 51 45 40 34 29 40 34 29 25 20 17 13 10 8
GPM 1.49 1.31 1.14 0.98 0.84 1.14 0.98 0.84 0.70 0.58 0.47 0.37 0.28 0.21 0.8
150 RPM
BPD 153 135 118 102 87 118 102 87 73 60 49 39 30 22
200 RPM
GPM 4.46 3.92 3.42 2.95 2.51 3.42 2.95 2.51 2.11 1.74 1.41 1.12 0.85 0.63 2.3
BPD 204 180 157 135 115 157 135 115 97 80 65 51 40 29
250 RPM
GPM 5.95 5.23 4.56 3.93 3.35 4.56 3.93 3.35 2.81 2.32 1.88 1.49 1.14 0.84
BPD 255 225 196 169 144 196 169 144 121 100 81 64 49 36
4.0
50 RPM 150 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 4455 0.34 0.09 1.01 0.28 5069 0.30 0.08 0.89 0.25 5819 0.26 0.07 0.78 0.22 6749 0.22 0.06 0.67 0.19 7920 0.19 0.05 0.57 0.16 5819 0.26 0.07 0.78 0.22 6749 0.22 0.06 0.67 0.19 7920 0.19 0.05 0.57 0.16 9426 0.16 0.04 0.48 0.13 11405 0.13 0.04 0.40 0.11 14081 0.11 0.03 0.32 0.09 17821 0.08 0.02 0.25 0.07 23276 0.06 0.02 0.19 0.05 31681 0.05 0.01 0.14 0.04 0.6 1.7
200 RPM
M3/Hr 1.35 1.19 1.03 0.89 0.76 1.03 0.89 0.76 0.64 0.53 0.43 0.34 0.26 0.19
L/Sec. 0.38 0.33 0.29 0.25 0.21 0.29 0.25 0.21 0.18 0.15 0.12 0.09 0.07 0.05 3.0
GPM 7.44 6.54 5.69 4.91 4.18 5.69 4.91 4.18 3.52 2.91 2.35 1.86 1.42 1.05 3.9
250 RPM
M3/Hr 1.69 1.48 1.29 1.12 0.95 1.29 1.12 0.95 0.80 0.66 0.53 0.42 0.32 0.24
300 RPM
BPD 306 269 235 203 173 235 203 173 145 120 97 77 59 44
GPM 8.92 7.84 6.83 5.89 5.02 6.83 5.89 5.02 4.22 3.49 2.82 2.23 1.71 1.26
350 RPM
BPD 357 314 274 236 201 274 236 201 169 140 113 90 69 51
GPM 10.41 9.15 7.97 6.87 5.86 7.97 6.87 5.86 4.92 4.07 3.29 2.60 1.99 1.46
4.7
5.5
300 RPM
350 RPM
L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. 0.47 2.03 0.56 2.36 0.66 0.41 1.78 0.49 2.08 0.58 0.36 1.55 0.43 1.81 0.50 0.31 1.34 0.37 1.56 0.43 0.26 1.14 0.32 1.33 0.37 0.36 1.55 0.43 1.81 0.50 0.31 1.34 0.37 1.56 0.43 0.26 1.14 0.32 1.33 0.37 0.22 0.96 0.27 1.12 0.31 0.18 0.79 0.22 0.92 0.26 0.15 0.64 0.18 0.75 0.21 0.12 0.51 0.14 0.59 0.16 0.09 0.39 0.11 0.45 0.13 0.07 0.29 0.08 0.33 0.09 2.9 3.5 4.1
Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 72% Mechanical Efficiency. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
11D-2 Duplex Plunger Pump Specifications C/2 3.25 9.12
C
10.44
3.25
%%c 1.500^1.499;
.375 x .188 KEYWAYP2.000 LONG
DISCHARGEPCONNE CTION
F5.9
.44 A 13.38 B 7.06
.63 TYP SUCTIONPCONNECTI ON 2.50
13.75
5.75
DP20.38
Pump Size: maximum plunger size x stroke length, in.(mm) 2.000 x 2.188 (50.8 x 55.56) Rated BHP (kW) at 400 RPM: 11 (8) Rated plunger load, pounds (kg) 2030 (921) Maximum discharge pressure: psi (kPa) “L” model: 1149 (7920) “M” model: 2042 (14081) “H” model: 4595 (31681) Crankshaft extension: Diameter, in.(mm): 1.500 (38.1) Length, in.(mm): 3.375 (85.73) Keyway width x depth, in.(mm): 3/8 x 3/16 (9.53 x 4.76) Maximum recommended sheave diameter, in.(mm): 25 (635) For larger sizes: Contact Factory Oil Capacity, gallons (L) Crankcase: 7/8 (3.31) Weight, pump only on wood shipping skids, pounds (kg) “L” model: 305 (138) “M” model: 305 (138) “H” model: 350 (159) Standard Materials for Fluid Ends: “L” model Cast Ductile Iron Cast Nickel-Aluminum-Bronze Forged 316 Stainless Steel Forged/Plate Carbon Steel “M” model Cast Ductile Iron Cast Nickel-Aluminum-Bronze Forged 316 Stainless Steel Forged/Plate Carbon Steel “H” model Forged 15-5 Stainless Steel
22.70PSUCTION & DISCHARGE
EP29.34
Pump Model 11D-2L 11D-2M 11D-2H
Flange Connections Discharge Connection Sizes Suction Connection Sizes 1 (25.4)-11 1/2 NPT 2 (50.8)-11 1/2 NPT 1 (25.4)-11 1/2 NPT 2 (50.8)-11 1/2 NPT 3/4 (19.05)-14 NPT 1 1/4 (31.75)-11 1/2 NPT
A 3 1/8 3 1/8 3 3/4
Dimensions (Inches) B C D E 4 7/8 7 1/2 20 3/8 29 3/8 4 7/8 7 1/2 20 3/8 29 3/8 4 1/4 9 1/2 20 32 1/8
F 6 6 7 7/8
11D-2 Duplex Plunger Pump Performance Data PUMP
11D-2L (P100ALS)
11D-2M (P100A)
11D-2H (P100H)
PUMP
11D-2L (P100ALS)
11D-2M (P100A)
11D-2H (P100H)
English Units Plunger Plunger BPD Dia. Area per In. Sq. In. RPM 2.000 3.1416 2.0400 1.875 2.7612 1.7930 1.750 2.4053 1.5619 1.625 2.0739 1.3467 1.500 1.7671 1.1475 1.750 2.4053 1.5619 1.625 2.0739 1.3467 1.500 1.7671 1.1475 1.375 1.4849 0.9642 1.250 1.2272 0.7969 1.125 0.9940 0.6455 1.000 0.7854 0.5100 0.875 0.6013 0.3905 0.750 0.4418 0.2869 Brake Horsepower Required
GPM per RPM 0.0595 0.0523 0.0456 0.0393 0.0335 0.0456 0.0393 0.0335 0.0281 0.0232 0.0188 0.0149 0.0114 0.0084
Metric Units Plunger Plunger Dia. Area mm cm2 51 20.268 48 17.814 44 15.518 41 13.380 38 11.401 44 15.518 41 13.380 38 11.401 35 9.580 32 7.917 29 6.413 25 5.067 22 3.879 19 2.850 Kilowatts Required
L/Sec. per RPM 0.0038 0.0033 0.0029 0.0025 0.0021 0.0029 0.0025 0.0021 0.0018 0.0015 0.0012 0.0009 0.0007 0.0005
M3/Hr per RPM 0.0135 0.0119 0.0103 0.0089 0.0076 0.0103 0.0089 0.0076 0.0064 0.0053 0.0043 0.0034 0.0026 0.0019
50 RPM Max. Press. PSI 646 735 844 979 1149 844 979 1149 1367 1654 2042 2585 3376 4595
BPD 102 90 79 68 58 79 68 58 49 40 33 26 20 15
GPM 3.0 2.6 2.3 2.0 1.7 2.3 2.0 1.7 1.4 1.2 0.9 0.7 0.6 0.4 2
150 RPM
BPD 306 269 235 203 173 235 203 173 145 120 97 77 59 44
200 RPM
GPM 8.9 7.8 6.8 5.9 5.0 6.8 5.9 5.0 4.2 3.5 2.8 2.2 1.7 1.3
BPD 408 359 313 270 230 313 270 230 193 160 130 102 79 58
5
50 RPM 150 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 4455 0.68 0.19 2.03 0.56 5069 0.59 0.16 1.78 0.49 5819 0.52 0.14 1.55 0.43 6749 0.45 0.12 1.34 0.37 7920 0.38 0.11 1.14 0.32 5819 0.52 0.14 1.55 0.43 6749 0.45 0.12 1.34 0.37 7920 0.38 0.11 1.14 0.32 9426 0.32 0.09 0.96 0.27 11405 0.26 0.07 0.79 0.22 14081 0.21 0.06 0.64 0.18 17821 0.17 0.05 0.51 0.14 23276 0.13 0.04 0.39 0.11 31681 0.10 0.03 0.29 0.08 1 4
250 RPM
GPM 11.9 10.5 9.1 7.9 6.7 9.1 7.9 6.7 5.6 4.6 3.8 3.0 2.3 1.7
BPD 510 449 391 337 287 391 337 287 242 200 162 128 98 72
GPM 14.9 13.1 11.4 9.8 8.4 11.4 9.8 8.4 7.0 5.8 4.7 3.7 2.8 2.1
350 RPM
BPD 714 628 547 472 402 547 472 402 338 279 226 179 137 101
GPM 20.8 18.3 15.9 13.7 11.7 15.9 13.7 11.7 9.8 8.1 6.6 5.2 4.0 2.9
400 RPM
BPD 816 718 625 539 459 625 539 459 386 319 259 204 157 115
GPM 23.8 20.9 18.2 15.7 13.4 18.2 15.7 13.4 11.2 9.3 7.5 5.9 4.6 3.3
6
7
10
11
200 RPM
250 RPM
350 RPM
400 RPM
M3/Hr 2.70 2.38 2.07 1.78 1.52 2.07 1.78 1.52 1.28 1.06 0.86 0.68 0.52 0.38
L/Sec. 0.75 0.66 0.57 0.50 0.42 0.57 0.50 0.42 0.35 0.29 0.24 0.19 0.14 0.11
M3/Hr 3.38 2.97 2.59 2.23 1.90 2.59 2.23 1.90 1.60 1.32 1.07 0.84 0.65 0.48
4
L/Sec. M3/Hr 0.94 4.73 0.82 4.16 0.72 3.62 0.62 3.12 0.53 2.66 0.72 3.62 0.62 3.12 0.53 2.66 0.44 2.24 0.37 1.85 0.30 1.50 0.23 1.18 0.18 0.91 0.13 0.67 5
L/Sec. M3/Hr 1.31 5.40 1.15 4.75 1.01 4.14 0.87 3.57 0.74 3.04 1.01 4.14 0.87 3.57 0.74 3.04 0.62 2.55 0.51 2.11 0.42 1.71 0.33 1.35 0.25 1.03 0.18 0.76 7
L/Sec. 1.50 1.32 1.15 0.99 0.84 1.15 0.99 0.84 0.71 0.59 0.48 0.38 0.29 0.21 8
Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 80% Mechanical Efficiency. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
22T-2 Triplex Plunger Pump Specifications
ÿ.750 TYP
4.00 TYP
5.25
24.13
5.25
12.94
ÿ
2.000 1.999
.500 X .250 KEYWAY 2.625 LONG
DISCHARGE CONNECTION
C
.44 A 14.25 B 7.50
SUCTION CONNECTION
.63 2.50
13.75
5.75
D
E
Pump Model 22T-2L 22T-2M 22T-2H
Flange Connections Discharge Connection Sizes Suction Connection Sizes 1 (25.4)-11 1/2 NPT 2 (50.8)-11 1/2 NPT 1 (25.4)-11 1/2 NPT 2 (50.8)-11 1/2 NPT 3/4 (19.1)-14 NPT 1 1/4 (31.8)-11 1/2 NPT
A 3 1/8 3 1/8 3 3/4
Pump Size: maximum plunger size x stroke length, in.(mm) 2.000 x 2.250 (50.8 x 57.15) Rated BHP (kW) at 465 RPM: 22 (17) Rated plunger load, pounds (kg): 2550 (1157) Maximum discharge pressure: psi (kPa) “L” model: 1443 (9949) “M” model: 2565 (17688) “H” model: 4600 (39797) Crankshaft extension: Diameter, in.(mm): 2.000 (50.8) Length, in.(mm) : 3.875 (98.43) Keyway width x depth, in.(mm): 1/2 x 1/4 (12.7 x 6.35) Maximum recommended sheave diameter, in.(mm): 33.5 (850.9) For larger sizes: Contact Customer Service Pinion shaft extension, if gear reducer is supplied in.(mm) For belt or chain drive: N/A For direct drive: Diameter: N/A Length: N/A Keyway (width x length): N/A Accessory gear reduction unit ratio: N/A Oil Capacity, gallons (L) Crankcase: 1-1/4 (4.73) Gear Reducer - varies with ratio: N/A Weight, pump only on wood shipping skids, pounds (kg) “L” model: 395 (179) “M” model: 395 (179) “H” model: 395 (179) Standard Materials for Fluid Ends: “L” model Cast Ductile Iron Cast Nickel-Aluminum-Bronze Cast 316 Stainless Steel Forged/Plate Carbon Steel “M” model Cast Ductile Iron Cast Nickel-Aluminum-Bronze Cast 316 Stainless Steel Forged/Plate Carbon Steel “H” model Forged 15-5 Stainless Steel
Dimensions (Inches) B C D E 4 7/8 5 15/16 22 5/8 29 1/2 4 7/8 5 15/16 22 5/8 29 1/2 4 1/4 7 7/8 20 32 1/8
F 11 1/2 11 1/2 13 1/2
22T-2 Triplex Plunger Pump Performance Data PUMP
22T-2L (T225LS)
22T-2M (T225M)
22T-2H (T225H)
PUMP
22T-2L (T225LS)
22T-2M (T225M)
22T-2H (T225H)
English Units Plunger Plunger BPD Dia. Area per In. Sq. In. RPM 2.000 3.1416 3.1474 1.875 2.7612 2.7663 1.750 2.4053 2.4097 1.625 2.0739 2.0778 1.500 1.7671 1.7704 1.750 2.4053 2.4097 1.625 2.0739 2.0778 1.500 1.7671 1.7704 1.375 1.4849 1.4876 1.250 1.2272 1.2295 1.125 0.9940 0.9959 1.000 0.7854 0.7869 0.875 0.6013 0.6024 0.750 0.4418 0.4426 Brake Horsepower Required
Metric Units Plunger Plunger Dia. Area cm cm2 51 20.268 48 17.814 44 15.518 41 13.380 38 11.401 44 15.518 41 13.380 38 11.401 35 9.580 32 7.917 29 6.413 25 5.067 22 3.879 19 2.850 Kilowatts Required
50 RPM GPM per RPM 0.0918 0.0807 0.0703 0.0606 0.0516 0.0703 0.0606 0.0516 0.0434 0.0359 0.0290 0.0229 0.0176 0.0129
Max. Press. PSI 812 924 1060 1230 1443 1060 1230 1443 1717 2050 2050 3247 4241 4600
BPD 158 139 121 104 89 121 104 89 75 62 50 40 31 23
GPM 4.6 4.0 3.5 3.0 2.6 3.5 3.0 2.6 2.2 1.8 1.5 1.1 0.9 0.6 2.4
50 RPM M3/Hr per RPM 0.0208 0.0183 0.0160 0.0138 0.0117 0.0160 0.0138 0.0117 0.0099 0.0081 0.0066 0.0052 0.0040 0.0029
L/Sec. per RPM 0.0058 0.0051 0.0044 0.0038 0.0033 0.0044 0.0038 0.0033 0.0027 0.0023 0.0018 0.0014 0.0011 0.0008
Max. Press. kPa 5596 6368 7310 8477 9949 7310 8477 9949 11840 14134 14134 22386 29239 31716
M3/Hr 1.04 0.92 0.80 0.69 0.59 0.80 0.69 0.59 0.49 0.41 0.33 0.26 0.20 0.15
L/Sec. 0.29 0.25 0.22 0.19 0.16 0.22 0.19 0.16 0.14 0.11 0.09 0.07 0.06 0.04 1.8
150 RPM
BPD 473 415 362 312 266 362 312 266 224 185 150 119 91 67
GPM 13.8 12.1 10.5 9.1 7.7 10.5 9.1 7.7 6.5 5.4 4.4 3.4 2.6 1.9
200 RPM
BPD 630 554 482 416 355 482 416 355 298 246 200 158 121 89
GPM 18.4 16.1 14.1 12.1 10.3 14.1 12.1 10.3 8.7 7.2 5.8 4.6 3.5 2.6
250 RPM
BPD 787 692 603 520 443 603 520 443 372 308 249 197 151 111
GPM 22.9 20.2 17.6 15.2 12.9 17.6 15.2 12.9 10.8 9.0 7.3 5.7 4.4 3.2
350 RPM
BPD 1102 969 844 728 620 844 728 620 521 431 349 276 211 155
GPM 32.1 28.2 24.6 21.2 18.1 24.6 21.2 18.1 15.2 12.6 10.2 8.0 6.1 4.5
465 RPM
BPD 1464 1287 1121 967 824 1121 967 824 692 572 464 366 281 206
GPM 42.7 37.5 32.7 28.2 24.0 32.7 28.2 24.0 20.2 16.7 13.5 10.7 8.2 6.0
7.2
9.7
12
17
22
150 RPM
200 RPM
250 RPM
350 RPM
465 RPM
M3/Hr 3.13 2.75 2.39 2.06 1.76 2.39 2.06 1.76 1.48 1.22 0.99 0.78 0.60 0.44
L/Sec. 0.87 0.76 0.67 0.57 0.49 0.67 0.57 0.49 0.41 0.34 0.27 0.22 0.17 0.12 5.4
M3/Hr 4.17 3.66 3.19 2.75 2.35 3.19 2.75 2.35 1.97 1.63 1.32 1.04 0.80 0.59
L/Sec. 1.16 1.02 0.89 0.76 0.65 0.89 0.76 0.65 0.55 0.45 0.37 0.29 0.22 0.16 7.2
M3/Hr 5.21 4.58 3.99 3.44 2.93 3.99 3.44 2.93 2.46 2.04 1.65 1.30 1.00 0.73
L/Sec. 1.45 1.27 1.11 0.96 0.81 1.11 0.96 0.81 0.68 0.57 0.46 0.36 0.28 0.20 9.0
M3/Hr 7.30 6.41 5.59 4.82 4.10 5.59 4.82 4.10 3.45 2.85 2.31 1.82 1.40 1.03
L/Sec. 2.03 1.78 1.55 1.34 1.14 1.55 1.34 1.14 0.96 0.79 0.64 0.51 0.39 0.29 13
M3/Hr 9.69 8.52 7.42 6.40 5.45 7.42 6.40 5.45 4.58 3.79 3.07 2.42 1.86 1.36
L/Sec. 2.69 2.37 2.06 1.78 1.51 2.06 1.78 1.51 1.27 1.05 0.85 0.67 0.52 0.38 17
Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
30T-2 Triplex Plunger Pump Specifications
1/2" x 1/4" KEYWAY
7/1 6
8
1.750 1.749
13/ 16 (USABLE SHAFT EXTENSION)
3
20
5/1 6
DIA.
4
CENTERLINE PLUNGER #1
"C"
9/1 6 6
4
13
1/ 8
CENTERLINE PLUNGER #2
CENTERLINE PLUNGER #3
1/ 14 8
"C"\2
DIA.
4
9/1 6
4-7/8" HOLES 2.500 2.499
SHAFT EXTENSION FOR DIRECT DRIVE 5/8" x 5/16" KEYWAY
1" NPT (TYP. BOTH SIDES)
Pump Size (maximum plunger size x stroke length in.(mm) 2 1/4 x 2 (57.2 x 50.8) Rated bhp at 500 rpm (kw): 30 (22.4) Rated plunger load pounds(Kg): 3565 (1617) Maximum discharge pressure: psi(kPa) L model: 2000 (13,788) H model: 5000 (34,470) Crankshaft extension: in.(mm) Diameter: 2.5/2.499 (63.5/63.4746) Length: 4 15/16 (125.4) Keyway (width x depth): 5/8 x 5/16 (15.88 x 7.94) Maximum recommended sheave in.(mm): 37.5 (952.5) Minimum recommeded sheave in.(mm): 20 (508) For larger sizes: Contact Customer Service Pinion shaft extension, if gear reducer is supplied in.(mm) For belt or chain drive: Contact Customer Service For direct drive: Diameter: 1.75/1.749 (44.5/44.425) Length: 3 13/16 (96.8) Keyway (width x depth): 1/2 x 1/4 (12.7 x 6.4) Accessory gear reduction unit ratio: 3.50:1, 3.83:1, 4.2:1 Oil Capacity gallons (L) Crankcase: 1.2 (4.5) Gear Reducer: 2/3 (2.5) Weight, pump only on wood shipping skids pounds (Kg): 640 (290) Gear reducer, approximate pounds (Kg): 300 (136.08)
CENTERLINE DISCHARGE
11
"A"
A
5
3/ 4
"B" CENTERLINE SUCTION
3/ 4
5
1 1/2" STD. PIPE TAP (CRADLE DRAIN) 7/ 21 8 3/ 4
21 6
"D" "E"
Pump Model 30T-2L Threaded 30T-2L Flanged 30T-2H
Flange Connections Discharge Connection Sizes Suction Connection Sizes 1 1/2 (38.10) Int. Pipe Thds. 2 1/2 (63.5) Int. Pipe Thds. 1 1/2 (38.10) API-2000 RJ 2 1/2 (63.5) ANSI-150 FF 1 (25.4) ANSI-2500 RJ 2 (50.8) ANSI-300 FF
A 3 3/4 3 3/4 3 5/8
Dimensions in inches (mm) B C D E 4 1/4 15 3/4 24 9/16 32 7/8 4 1/4 18 1/4 24 9/16 34 1/16 4 17 1/2 24 5/16 33 9/16
30T-2 Triplex Plunger Pump Performance Data PUMP
30T-2L
30T-2H
PUMP
30T-2L
30T-2H
English Units Plunger Plunger BPD Dia. Area per In. Sq. In. RPM 2.250 3.9761 3.5410 2.000 3.1416 2.7980 1.750 2.4053 2.1430 1.500 1.7671 1.5737 1.500 1.7671 1.5737 1.375 1.4849 1.3234 1.250 1.2272 1.0937 1.125 0.9940 0.8846 1.000 0.7854 0.6994 0.938 0.6910 0.6137 Brake Horsepower Required
GPM per RPM 0.1033 0.0816 0.0625 0.0459 0.0459 0.0386 0.0319 0.0258 0.0204 0.0179
Metric Units Plunger Plunger Dia. Area mm cm2 57 25.652 51 20.268 44 15.518 38 11.401 38 11.401 35 9.580 32 7.917 29 6.413 25 5.067 24 4.458 Kilowatts Required
L/Sec. per RPM 0.0065 0.0051 0.0039 0.0029 0.0029 0.0024 0.0020 0.0016 0.0013 0.0011
M3/Hr per RPM 0.0235 0.0185 0.0142 0.0104 0.0104 0.0088 0.0072 0.0059 0.0046 0.0041
200 * RPM Max. Press. PSI 897 1135 1482 2000 2000 2401 2905 3586 4539 5000
BPD GPM 709 20.66 560 16.32 429 12.50 315 9.18 315 9.18 265 7.72 219 6.38 177 5.16 140 4.08 123 3.58 12.0
300 RPM
BPD 1063 840 643 473 473 398 329 266 210 185
350 RPM
GPM 30.99 24.48 18.75 13.77 13.77 11.58 9.57 7.74 6.12 5.37 18.0
BPD 1240 980 751 551 551 464 383 310 245 215
200 * RPM 300 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 6185 4.69 1.30 7.04 1.96 7826 3.71 1.03 5.56 1.54 10218 2.84 0.79 4.26 1.18 13790 2.08 0.58 3.13 0.87 13790 2.08 0.58 3.13 0.87 16554 1.75 0.49 2.63 0.73 20029 1.45 0.40 2.17 0.60 24725 1.17 0.33 1.76 0.49 31295 0.93 0.26 1.39 0.39 34474 0.81 0.23 1.22 0.34 8.9 13.4
GPM 36.16 28.56 21.88 16.07 16.07 13.51 11.17 9.03 7.14 6.27 21.0
350 RPM
M3/Hr L/Sec. 8.21 2.28 6.49 1.80 4.97 1.38 3.65 1.01 3.65 1.01 3.07 0.85 2.54 0.70 2.05 0.57 1.62 0.45 1.42 0.40 15.7
400 RPM
BPD 1417 1120 858 630 630 530 438 354 280 246
GPM 41.32 32.64 25.00 18.36 18.36 15.44 12.76 10.32 8.16 7.16 24
400 RPM
M3/Hr 9.38 7.41 5.68 4.17 4.17 3.51 2.90 2.34 1.85 1.63
450 RPM
BPD 1594 1260 965 709 709 596 493 399 315 277
GPM 46.49 36.72 28.13 20.66 20.66 17.37 14.36 11.61 9.18 8.06
500 RPM
BPD 1771 1399 1072 787 787 662 547 443 350 307
GPM 51.65 40.80 31.25 22.95 22.95 19.30 15.95 12.90 10.20 8.95
27
30
450 RPM
500 RPM
L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. 2.61 10.56 2.93 11.73 3.26 2.06 8.34 2.32 9.27 2.57 1.58 6.39 1.77 7.10 1.97 1.16 4.69 1.30 5.21 1.45 1.16 4.69 1.30 5.21 1.45 0.97 3.94 1.10 4.38 1.22 0.81 3.26 0.91 3.62 1.01 0.65 2.64 0.73 2.93 0.81 0.51 2.08 0.58 2.32 0.64 0.45 1.83 0.51 2.03 0.56 18 20 22
Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. * For operations below 200 RPM, auxiliary lubrication system required. Not all plunger sizes are shown. Contact National-Oilwell for additional information. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
31Q-2 Quintuplex Plunger Pump Specifications
15.12 C/2
C 18.50
9.25 12.69
4.31
ÿ.75 TYP 4 PLACES
.500 x .250 x 3.75 LONG KEYWAY 2.1252 .124
ÿ
Pump Size: maximum plunger size x stroke length, in.(mm): 1.750 x 2.250 (44.5 x 57.15) Rated BHP (kW) at 490 RPM: 31 (23) Rated plunger load, pounds (kg): 2030 (921) Maximum discharge pressure: psi (kPa) “L” model: 2042 (14081) Crankshaft extension: Diameter, in.(mm): 2.125 (53.98) Length, in.(mm): 4.31 (109.5) Keyway width x depth, in.(mm): 1/2 x 1/4 (12.7 x 6.35) Maximum recommended sheave diameter, in.(mm): 33.5 (850.9) For larger sizes: Contact Customer Service Oil Capacity, gallons (L) Crankcase: 2 (7.57) Gear Reducer-varies with ratio: N/A Weight, pump only on wood shipping skids, pounds (kg) “L” model: 658 (298) Standard Materials for Fluid Ends: “L” model Cast Ductile Iron Cast Nickel-Aluminum-Bronze Cast Duplex Stainless Steel Forged/Plate Carbon Steel
DISCHARGE CONNECTION
F A
4.81 13.38 .44
B
6.56
.63 2.50
SUCTION CONNECTION
13.75
6.70
D
E
Pump Model Cast L.E. Forged L.E.
Flange Connections Discharge Connection Sizes Suction Connection Sizes 1 NPT (25.4)-11 1/2 THDS 2 NPT (50.8)-11 1/2 THDS 1 NPT (25.4)-11 1/2 THDS 2 NPT (50.8)-11 1/2 THDS
A 3 3/8 3 1/2
Dimensions (Inches) B C D E 4 7/8 19 1/2 22 5/8 30 3/8 4 7/8 20 20 3/8 30 3/8
F 5 15/16 6 3/16
31Q-2 Quintuplex Plunger Pump Performance Data PUMP
31Q-2L (5P200A)
PUMP
31Q-2L (5P200A)
English Units Plunger Plunger BPD Dia. Area per In. Sq. In. RPM 1.750 2.4053 4.0162 1.625 2.0739 3.4630 1.500 1.7671 2.9507 1.375 1.4849 2.4794 1.250 1.2272 2.0491 1.125 0.9940 1.6598 Brake Horsepower Required
GPM per RPM 0.1171 0.1010 0.0861 0.0723 0.0598 0.0484
Metric Units Plunger Plunger Dia. Area cm cm2 44 15.518 41 13.380 38 11.401 35 9.580 32 7.917 29 6.413 Kilowatts Required
L/Sec. per RPM 0.0074 0.0064 0.0054 0.0046 0.0038 0.0031
M3/Hr per RPM 0.0266 0.0229 0.0195 0.0164 0.0136 0.0110
50 RPM Max. Press. PSI 844 979 1149 1367 1654 2042
BPD 201 174 148 124 103 83
GPM 5.86 5.05 4.30 3.62 2.99 2.42 4
150 RPM
BPD 603 520 443 372 308 249
250 RPM
GPM 17.6 15.2 12.9 10.8 8.96 7.26
BPD 1005 866 738 620 513 415
10
50 RPM 150 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 5819 1.33 0.37 3.99 1.11 6749 1.15 0.32 3.44 0.96 7920 0.98 0.27 2.93 0.81 9426 0.82 0.23 2.46 0.68 11405 0.68 0.19 2.04 0.57 14081 0.55 0.15 1.65 0.46 3.0 7.5
350 RPM
GPM 29.3 25.3 21.5 18.1 14.9 12.1
BPD 1406 1213 1033 868 718 581
GPM 41.0 35.4 30.1 25.3 20.9 16.9
400 RPM
BPD 1607 1386 1181 992 820 664
GPM 46.9 40.4 34.4 28.9 23.9 19.4
490 RPM
BPD 1968 1697 1446 1215 1005 814
GPM 57.4 49.5 42.2 35.4 29.3 23.7
17
22
26
31
250 RPM
350 RPM
400 RPM
490 RPM
M3/Hr 6.65 5.73 4.89 4.11 3.39 2.75
L/Sec. 1.85 1.59 1.36 1.14 0.94 0.76 13
M3/Hr 9.31 8.03 6.84 5.75 4.75 3.85
L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. 2.59 10.64 2.96 13.04 3.62 2.23 9.18 2.55 11.24 3.12 1.90 7.82 2.17 9.58 2.66 1.60 6.57 1.82 8.05 2.24 1.32 5.43 1.51 6.65 1.85 1.07 4.40 1.22 5.39 1.50 17 19 23
Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
32T-2 Triplex Plunger Pump Specifications
ÿ .75 TYP 4 PLACES
4.00 TYP
5.25
24.13
5.25
12.94
ÿ
2.000 1.999
.500 X .250 KEYWAY 2.625 LONG
DISCHARGE CONNECTION
C
.44 A 14.25 B 7.50
SUCTION CONNECTION
.63 2.50
13.75
5.75
Pump Size: maximum plunger size x stroke length, in.(mm): 2.000 x 2.250 (50.8 x 57.15) Rated BHP (kW) at 465 RPM: 32 (24) Rated plunger load, pounds (kg): Spec Maximum discharge pressure: psi (kPa) “L” model: 2037 (14046) “M” model: 2050 (14134) “H” model: 4600 (31716) Crankshaft extension: Diameter, in.(mm): 2.000 (50.8) Length, in.(mm): 3.875 (98.4) Keyway width x depth, in.(mm): 1/2 x 1/4 (12.7 x 6.35) Maximum recommended sheave diameter, in.(mm): 33.5 (850.9) For larger sizes: Contact Customer Service Pinion shaft extension, if gear reducer is supplied in.(mm) For belt or chain drive: N/A For direct drive: Diameter: N/A Length: N/A Keyway (width x length): N/A Accessory gear reduction unit ratio: N/A Oil Capacity, gallons (L) Crankcase: 1-1/4 (4.73) Gear Reducer-varies with ratio: N/A Weight, pump only on wood shipping skids, pounds (kg): 395 (179) Standard Materials for Fluid Ends: “L” & “M” models Cast Ductile Iron Cast Nickel-Aluminum-Bronze Cast 316 Stainless Steel Forged/Plate Carbon Steel “H” model Forged 15-5 Stainless Steel
D
E
Pump Model 32T-2L 32T-2M 32T-2H
Flange Connections Discharge Connection Sizes Suction Connection Sizes 1 (25.4)-11 1/2 NPT 2 (50.8)-11 1/2 NPT 1 (25.4)-11 1/2 NPT 2 (50.8)-11 1/2 NPT 3/4 (19.1)-14 NPT 1 1/4 (31.8)-11 1/2 NPT
A 3 3/8 3 1/8 3 3/4
Dimensions (Inches) B C D E 4 7/8 5 15/16 22 5/8 29 1/2 4 7/8 5 15/16 22 5/8 29 1/2 4 1/4 7 7/8 20 32 1/8
F 11 1/2 11 1/2 13 1/2
32T-2 Triplex Plunger Pump Performance Data PUMP
32T-2L (T225LS)
32T-2M (T225M)
32T-2H (T225H)
PUMP
32T-2L (T225LS)
32T-2M (T225M)
32T-2H (T225H)
English Units Plunger Plunger BPD Dia. Area per In. Sq. In. RPM 2.000 3.1416 3.1474 1.875 2.7612 2.7663 1.750 2.4053 2.4097 1.625 2.0739 2.0778 1.500 1.7671 1.7704 1.750 2.4053 2.4097 1.625 2.0739 2.0778 1.500 1.7671 1.7704 1.375 1.4849 1.4876 1.250 1.2272 1.2295 1.125 0.9940 0.9959 1.000 0.7854 0.7869 0.875 0.6013 0.6024 0.750 0.4418 0.4426 Brake Horsepower Required
GPM per RPM 0.0918 0.0807 0.0703 0.0606 0.0516 0.0703 0.0606 0.0516 0.0434 0.0359 0.0290 0.0229 0.0176 0.0129
Metric Units Plunger Plunger Dia. Area cm cm2 51 20.268 48 17.814 44 15.518 41 13.380 38 11.401 44 15.518 41 13.380 38 11.401 35 9.580 32 7.917 29 6.413 25 5.067 22 3.879 19 2.850 Kilowatts Required
L/Sec. per RPM 0.0058 0.0051 0.0044 0.0038 0.0033 0.0044 0.0038 0.0033 0.0027 0.0023 0.0018 0.0014 0.0011 0.0008
M3/Hr per RPM 0.0208 0.0183 0.0160 0.0138 0.0117 0.0160 0.0138 0.0117 0.0099 0.0081 0.0066 0.0052 0.0040 0.0029
50 RPM Max. Press. PSI 1146 1304 1497 1736 2037 1497 1736 2037 2050 2050 2050 4584 4600 4600
BPD 158 139 121 104 89 121 104 89 75 62 50 40 31 23
GPM 4.59 4.03 3.51 3.03 2.58 3.51 3.03 2.58 2.17 1.79 1.45 1.15 0.88 0.65 3.4
150 RPM
200 RPM
BPD GPM 473 13.8 415 12.1 362 10.5 312 9.1 266 7.7 362 10.5 312 9.09 266 7.75 224 6.51 185 5.38 150 4.36 119 3.44 91 2.64 67 1.94 10.2
BPD 630 554 482 416 355 482 416 355 298 246 200 158 121 89
50 RPM 150 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 7901 1.04 0.29 3.13 0.87 8989 0.92 0.25 2.75 0.76 10319 0.80 0.22 2.39 0.67 11968 0.69 0.19 2.06 0.57 14046 0.59 0.16 1.76 0.49 10319 0.80 0.22 2.39 0.67 11968 0.69 0.19 2.06 0.57 14046 0.59 0.16 1.76 0.49 14134 0.49 0.14 1.48 0.41 14134 0.41 0.11 1.22 0.34 14134 0.33 0.09 0.99 0.27 31603 0.26 0.07 0.78 0.22 31716 0.20 0.06 0.60 0.17 31716 0.15 0.04 0.44 0.12 2.5 7.6
250 RPM
GPM 18.4 16.1 14.1 12.1 10.3 14.1 12.1 10.3 8.68 7.17 5.81 4.59 3.51 2.58 13.6
BPD 787 692 603 520 443 603 520 443 372 308 249 197 151 111
200 RPM
M3/Hr L/Sec. 4.17 1.16 3.66 1.02 3.19 0.89 2.75 0.76 2.35 0.65 3.19 0.89 2.75 0.76 2.35 0.65 1.97 0.55 1.63 0.45 1.32 0.37 1.04 0.29 0.80 0.22 0.59 0.16 10.2
GPM 22.9 20.2 17.6 15.2 12.9 17.6 15.2 12.9 10.8 8.96 7.26 5.74 4.39 3.23 17
250 RPM
M3/Hr 5.21 4.58 3.99 3.44 2.93 3.99 3.44 2.93 2.46 2.04 1.65 1.30 1.00 0.73
350 RPM
BPD 1102 969 844 728 620 844 728 620 521 431 349 276 211 155
GPM 32.1 28.2 24.6 21.2 18.1 24.6 21.2 18.1 15.2 12.6 10.2 8.03 6.15 4.52
465 RPM
BPD 1464 1287 1121 967 824 1121 967 824 692 572 464 366 281 206
GPM 42.7 37.5 32.7 28.2 24.0 32.7 28.2 24.0 20.2 16.7 13.5 10.7 8.17 6.00
24
32
350 RPM
465 RPM
L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. 1.45 7.30 2.03 9.69 2.69 1.27 6.41 1.78 8.52 2.37 1.11 5.59 1.55 7.42 2.06 0.96 4.82 1.34 6.40 1.78 0.81 4.10 1.14 5.45 1.51 1.11 5.59 1.55 7.42 2.06 0.96 4.82 1.34 6.40 1.78 0.81 4.10 1.14 5.45 1.51 0.68 3.45 0.96 4.58 1.27 0.57 2.85 0.79 3.79 1.05 0.46 2.31 0.64 3.07 0.85 0.36 1.82 0.51 2.42 0.67 0.28 1.40 0.39 1.86 0.52 0.20 1.03 0.29 1.36 0.38 12.7 18 24
Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
55T-3 Triplex Plunger Pump Specifications ÿ.75 TYP 2 PLACES 17.44
E/2
8.50
E
8.50 12.19 16.63
ÿ
2.500 2.499
.625 x .313 KEYWAY 3.875 LONG
D DISCHARGE CONNECTION
7.50
F
6.00 A 14.16 B
1.00 TYP
Pump Size: maximum plunger size x stroke length, in.(mm) 2.500 x 3.000 (63.5 x 76.2) Rated BHP (kW) at 500 RPM: 55 (41) Rated plunger load, pounds (kg): 4370 (1982) Maximum discharge pressure: psi (kPa) “L” model: 1391 (9591) “SC” model: 1817 (12527) “LS” model: 1480 (10204) “M” model: 3561 (24552) “MS” model: 2473 (17050) “H” model: 5564 (38363) Crankshaft extension: Diameter, in.(mm): 3.500 (88.9) Length, in.(mm): 3.875 (98.43) Keyway width x depth, in.(mm): 5/8 x 5/16 (15.88 x 7.94) Maximum recommended sheave in.(mm): 38 (965.2) For larger sizes: Contact Customer Service Oil Capacity, gallons (L) Crankcase: 2.50 (9.46) Weight, pump only on wood shipping skids, pounds (kg): 895 (406) Weight varies with pump model Standard Materials for Fluid Ends: “L” & “M” models Cast Nickel-Aluminum-Bronze “SC” model Cast Ductile Iron “LS”, “MS”, & “H” models Carbon Steel Plate
SUCTION CONNECTION 5/8-11UNC-3B 3/4 FULL THREAD 1 PLACE C
5.25
Pump Model 55T-3L 55T-3LS 55T-3M 55T-3MS 55T-3H
30.75
Flange Connections Discharge Connection Sizes Suction Connection Sizes 2 (50.8)-NPT 2 1/2 (63.5)-NPT 1 1/2 (38.1)-NPT 2 (50.8)-NPT 2 (50.8)-NPT 2 1/2 (63.5)-NPT 1 1/2 (38.1)-NPT 2 (50.8)-NPT 1 1/2 (38.1)-NPT 2 (50.8)-NPT
A 3 3/16 3 3/8 3 3/16 3 3/8 3 3/8
Dimensions (Inches) B C D E 3 3/4 28 3/4 39 3/16 18 4 28 3/4 41 18 1/2 3 3/4 28 3/4 39 3/16 18 4 28 3/4 41 18 1/2 4 28 3/4 41 18 1/2
F 5 11/32 6 15/32 5 11/32 6 15/32 6 15/32
55T-3 Triplex Plunger Pump Performance Data PUMP
55T-3L (3364-7) 55T-3SC (3364-5SC) 55T-3LS (3364-6)
55T-3M (3364-3) 55T-3MS (3364-2) 55T-3H (3364-1)
PUMP
55T-3L (3364-7) 55T-3SC (3364-5SC) 55T-3LS (3364-6)
55T-3M (3364-3) 55T-3MS (3364-2) 55T-3H (3364-1)
English Units Plunger Plunger BPD Dia. Area per In. Sq. In. RPM 2.500 4.9087 6.5571 2.250 3.9761 5.3113 2.000 3.1416 4.1966 2.250 3.9761 5.3113 2.000 3.1416 4.1966 1.750 2.4053 3.2130 2.500 4.9087 6.5571 2.250 3.9761 5.3113 2.000 3.1416 4.1966 1.750 2.4053 3.2130 1.750 2.4053 3.2130 1.500 1.7671 2.3606 1.250 1.2272 1.6393 1.750 2.4053 3.2130 1.500 1.7671 2.3606 1.250 1.2272 1.6393 1.000 0.7854 1.0491 Brake Horsepower Required
GPM per RPM 0.1912 0.1549 0.1224 0.1549 0.1224 0.0937 0.1912 0.1549 0.1224 0.0937 0.0937 0.0688 0.0478 0.0937 0.0688 0.0478 0.0306
Metric Units Plunger Plunger Dia. Area mm cm2 64 31.669 57 25.652 51 20.268 57 25.652 51 20.268 44 15.518 64 31.669 57 25.652 51 20.268 44 15.518 44 15.518 38 11.401 32 7.917 44 15.518 38 11.401 32 7.917 25 5.067 Kilowatts Required
L/Sec. per RPM 0.0121 0.0098 0.0077 0.0098 0.0077 0.0059 0.0121 0.0098 0.0077 0.0059 0.0059 0.0043 0.0030 0.0059 0.0043 0.0030 0.0019
M3/Hr per RPM 0.0434 0.0352 0.0278 0.0352 0.0278 0.0213 0.0434 0.0352 0.0278 0.0213 0.0213 0.0156 0.0109 0.0213 0.0156 0.0109 0.0069
100 RPM Max. Press. PSI 890 1099 1391 1099 1391 1817 890 1099 1391 1480 1817 2473 3561 1817 2473 3300 3300
BPD 656 532 420 532 420 322 656 532 420 322 322 237 164 322 237 164 105
GPM 19.12 15.49 12.24 15.49 12.24 9.37 19.12 15.49 12.24 9.37 9.37 6.88 4.78 9.37 6.88 4.78 3.06 11
200 RPM
BPD 1312 1063 840 1063 840 643 1312 1063 840 643 643 473 328 643 473 328 210
250 RPM
GPM 38.25 30.98 24.48 30.98 24.48 18.74 38.25 30.98 24.48 18.74 18.74 13.77 9.56 18.74 13.77 9.56 6.12
BPD 1640 1328 1050 1328 1050 804 1640 1328 1050 804 804 591 410 804 591 410 263
22
100 RPM 200 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 6138 4.34 1.21 8.69 2.41 7578 3.52 0.98 7.04 1.95 9591 2.78 0.77 5.56 1.54 7578 3.52 0.98 7.04 1.95 9591 2.78 0.77 5.56 1.54 12527 2.13 0.59 4.26 1.18 6138 4.34 1.21 8.69 2.41 7578 3.52 0.98 7.04 1.95 9591 2.78 0.77 5.56 1.54 10204 2.13 0.59 4.26 1.18 12527 2.13 0.59 4.26 1.18 17050 1.56 0.43 3.13 0.87 24552 1.09 0.30 2.17 0.60 12527 2.13 0.59 4.26 1.18 17050 1.56 0.43 3.13 0.87 24552 1.09 0.30 2.17 0.60 38363 0.69 0.19 1.39 0.39 8 16
GPM 47.81 38.73 30.60 38.73 30.60 23.43 47.81 38.73 30.60 23.43 23.43 17.21 11.95 23.43 17.21 11.95 7.65
350 RPM
BPD 2295 1859 1469 1859 1469 1125 2295 1859 1469 1125 1125 827 574 1125 827 574 368
GPM 66.94 54.22 42.84 54.22 42.84 32.80 66.94 54.22 42.84 32.80 32.80 24.10 16.73 32.80 24.10 16.73 10.71
420 RPM
BPD 2754 2231 1763 2231 1763 1350 2754 2231 1763 1350 1350 992 689 1350 992 689 441
GPM 80.32 65.06 51.41 65.06 51.41 39.36 80.32 65.06 51.41 39.36 39.36 28.92 20.08 39.36 28.92 20.08 12.85
500 * RPM
BPD 3279 2656 2099 2656 2099 1607 3279 2656 2099 1607 1607 1181 820 1607 1181 820 525
GPM 95.62 77.46 61.20 77.46 61.20 46.86 95.62 77.46 61.20 46.86 46.86 34.42 23.91 46.86 34.42 23.91 15.30
28
39
46
55
250 RPM
350 RPM
420 RPM
500 * RPM
M3/Hr 10.86 8.80 6.95 8.80 6.95 5.32 10.86 8.80 6.95 5.32 5.32 3.91 2.71 5.32 3.91 2.71 1.74
L/Sec. 3.02 2.44 1.93 2.44 1.93 1.48 3.02 2.44 1.93 1.48 1.48 1.09 0.75 1.48 1.09 0.75 0.48 21
M3/Hr 15.20 12.31 9.73 12.31 9.73 7.45 15.20 12.31 9.73 7.45 7.45 5.47 3.80 7.45 5.47 3.80 2.43
L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. 4.22 18.24 5.07 21.72 6.03 3.42 14.78 4.10 17.59 4.89 2.70 11.67 3.24 13.90 3.86 3.42 14.78 4.10 17.59 4.89 2.70 11.67 3.24 13.90 3.86 2.07 8.94 2.48 10.64 2.96 4.22 18.24 5.07 21.72 6.03 3.42 14.78 4.10 17.59 4.89 2.70 11.67 3.24 13.90 3.86 2.07 8.94 2.48 10.64 2.96 2.07 8.94 2.48 10.64 2.96 1.52 6.57 1.82 7.82 2.17 1.06 4.56 1.27 5.43 1.51 2.07 8.94 2.48 10.64 2.96 1.52 6.57 1.82 7.82 2.17 1.06 4.56 1.27 5.43 1.51 0.68 2.92 0.81 3.47 0.97 29 35 41
Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency.*For Speeds above 420 RPM - consult the Factory. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
59T-3 Triplex Plunger Pump Specifications 14.31
C 13.00
6.50 C/2 11.56
ÿ.75 TYP 4 PLACES
4.13
2.500 2.499
ÿ
ROTATION DIRECTION DISCHARGE CONNECTION
F A 17.89
.75
B
7.37
.63
4.00
G 7.43
SUCTION CONNECTION
19.38
D
E
Pump Model 59T-3L 59T-3M 59T-3MS 59T-3H
Flange Connections Discharge Connection Sizes Suction Connection Sizes 2 1/2 (63.5)-8 NPT 4 (101.6)-8 NPT 2 (50.8)-11 1/2 NPT 2 1/2 (63.5)-8 NPT 2 (50.8)-11 1/2 NPT 2 (63.5)-8 NPT 1 (25.4)-11 1/2 NPT 1 1/2 (38.1)-11 1/2 NPT
A 5 1/8 3 7/16 4 9/16 3 7/8
Pump Size: maximum plunger size x stroke length, in.(mm): 3.00 x 3.500 (76.2 x 88.9) Rated BHP (kW) at 420 RPM: 59 (44) Rated plunger load, pounds (kg): 4760 (2159) Maximum discharge pressure: psi (kPa) “L” model: 970 (6686) “M” model: 2295 (15825) “MS” model: 4789 (33017) “H” model: 10000 (68948) Crankshaft extension: Diameter, in.(mm): 2.500 (63.5) Length, in (mm): 4.13 (104.9) Keyway width x depth, in.(mm): 5/8 x 5/16 (15.88 x 7.94) Maximum recommended sheave diameter, in.(mm): 38 (965.2) For larger sizes: Contact Factory Pinion shaft extension, if gear reducer is supplied, in.(mm) For belt or chain drive: N/A For direct drive: Diameter: 2.000 (50.8) Length: 4.250 (108.0) Keyway width x depth: 1/2 x 1/4 (12.70 x 6.35) Accessory gear reduction unit: 3.00:1, 3.12:1, 3.23:1, 3.36:1, 3.49:1, 3.62:1, 3.78:1, 3.94:1, 4.11:1, 4.29:1, 4.48:1, 4.69:1, 4.93:1, 5.17:1 Oil Capacity, gallons (L) Crankcase: 2.50 (9.46) Gear Reducer - varies with ratio: 1.25 to 1.50 (4.73 to 5.68) Weight, pump only on wood shipping skids, pounds (kg) “L” model: 1100 (499) “M” model: 980 (445) “MS” model: 1080 (490) “H” model: 1035 (469) Standard Materials For Fluid End Bodies “L” model Cast Ductile Iron Forged/Plate Carbon Steel Cast Nickel-Aluminum-Bronze Cast Duplex Stainless Steel “M” model Cast Ductile Iron Cast/Forged/Plate Carbon Steel Cast Nickel-Aluminum-Bronze Cast Duplex Stainless Steel “MS” model Forged Nickel-Aluminum-Bronze Forged 316 Stainless Steel Forged/Plate Carbon Steel “H” model Forged 15-5 Stainless Steel
Dimensions (Inches) B C D E 7 17 1/8 28 41 1/16 5 3/8 16 5/8 27 3/16 40 5/16 5 3/8 16 1/2 26 7/8 40 1/16 4 3/8 28 24 3/4 39 5/8
F 9 7/8 8 1/8 9 5/16 8 3/16
G 1 7/8 -3/4 -7/8 -7/8
59T-3 Triplex Plunger Pump Performance Data PUMP
59T-3L (T365AL)
59T-3M (T365AM)
59T-3MS (T365MS)
59T-3H (T365H)
PUMP
59T-3L (T365AL)
59T-3M (T365AM)
59T-3MS (T365MS)
59T-3H (T365H)
English Units Plunger Plunger BPD Dia. Area per In. Sq. In. RPM 3.000 7.0686 11.0160 2.875 6.4918 10.1171 2.750 5.9396 9.2565 2.625 5.4119 8.4341 2.500 4.9087 7.6500 2.500 4.9087 7.6500 2.375 4.4301 6.9041 2.250 3.9761 6.1965 2.125 3.5466 5.5271 2.000 3.1416 4.8960 1.875 2.7612 4.3031 1.750 2.4053 3.7485 1.625 2.0739 3.2321 1.500 1.7671 2.7540 1.375 1.4849 2.3141 1.250 1.2272 1.9125 1.125 0.9940 1.5491 1.000 0.7854 1.2240 0.875 0.6013 0.9371 0.750 0.4418 0.6885 Brake Horsepower Required
GPM per RPM 0.3213 0.2951 0.2700 0.2460 0.2231 0.2231 0.2014 0.1807 0.1612 0.1428 0.1255 0.1093 0.0943 0.0803 0.0675 0.0558 0.0452 0.0357 0.0273 0.0201
Metric Units Plunger Plunger Dia. Area mm cm2 76 45.604 73 41.883 70 38.320 67 34.915 64 31.669 64 31.669 60 28.581 57 25.652 54 22.881 51 20.268 48 17.814 44 15.518 41 13.380 38 11.401 35 9.580 32 7.917 29 6.413 25 5.067 22 3.879 19 2.850 Kilowatts Required
L/Sec. per RPM 0.0203 0.0186 0.0170 0.0155 0.0141 0.0141 0.0127 0.0114 0.0102 0.0090 0.0079 0.0069 0.0059 0.0051 0.0043 0.0035 0.0029 0.0023 0.0017 0.0013
M3/Hr per RPM 0.0730 0.0670 0.0613 0.0559 0.0507 0.0507 0.0457 0.0410 0.0366 0.0324 0.0285 0.0248 0.0214 0.0182 0.0153 0.0127 0.0103 0.0081 0.0062 0.0046
50 RPM Max. Press. PSI 673 733 801 880 970 970 1074 1197 1342 1515 1724 1979 2295 2694 3206 3879 4789 6061 7916 10000
BPD 551 506 463 422 383 383 346 310 277 245 216 188 162 138 116 96 78 62 47 35
GPM 16.1 14.8 13.50 12.30 11.16 11.16 10.07 9.04 8.06 7.14 6.28 5.47 4.71 4.02 3.37 2.79 2.26 1.78 1.37 1.00 7
150 RPM
BPD 1653 1518 1389 1266 1148 1148 1036 930 830 735 646 563 485 414 348 287 233 184 141 104
250 RPM
GPM 48.19 44.26 40.50 36.90 33.47 33.47 30.21 27.11 24.18 21.42 18.83 16.40 14.14 12.05 10.12 8.37 6.78 5.35 4.10 3.01
BPD 2754 2530 2315 2109 1913 1913 1727 1550 1382 1224 1076 938 809 689 579 479 388 306 235 173
21
50 RPM 150 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 4643 3.65 1.01 10.95 3.04 5055 3.35 0.93 10.05 2.79 5526 3.07 0.85 9.20 2.55 6064 2.79 0.78 8.38 2.33 6686 2.53 0.70 7.60 2.11 6686 2.53 0.70 7.60 2.11 7408 2.29 0.64 6.86 1.91 8254 2.05 0.57 6.16 1.71 9254 1.83 0.51 5.49 1.53 10447 1.62 0.45 4.86 1.35 11886 1.43 0.40 4.28 1.19 13645 1.24 0.34 3.72 1.03 15825 1.07 0.30 3.21 0.89 18572 0.91 0.25 2.74 0.76 22102 0.77 0.21 2.30 0.64 26744 0.63 0.18 1.90 0.53 33017 0.51 0.14 1.54 0.43 41787 0.41 0.11 1.22 0.34 54579 0.31 0.09 0.93 0.26 68948 0.23 0.06 0.68 0.19 5 16
GPM 80.32 73.77 67.50 61.50 55.78 55.78 50.34 45.18 40.30 35.70 31.38 27.33 23.57 20.08 16.87 13.95 11.30 8.92 6.83 5.02
300 RPM
BPD 3305 3036 2777 2531 2295 2295 2072 1859 1659 1469 1291 1125 970 827 695 574 465 368 282 207
GPM 96.39 88.52 80.99 73.80 66.94 66.94 60.41 54.22 48.36 42.84 37.65 32.80 28.28 24.10 20.25 16.73 13.55 10.71 8.20 6.02
350 RPM
BPD 3856 3541 3240 2952 2678 2678 2417 2169 1935 1714 1507 1312 1132 964 810 670 543 429 328 241
GPM 112.5 103.3 94.49 86.10 78.09 78.09 70.48 63.26 56.42 49.98 43.93 38.27 32.99 28.11 23.62 19.52 15.81 12.49 9.57 7.03
420 RPM
BPD 4627 4250 3888 3543 3213 3213 2900 2603 2322 2057 1808 1575 1358 1157 972 804 651 515 394 290
GPM 134.9 123.9 113.4 103.3 93.71 93.71 84.58 75.91 67.71 59.98 52.71 45.92 39.59 33.74 28.35 23.43 18.98 14.99 11.48 8.43
35
42
49
59
250 RPM
300 RPM
350 RPM
420 RPM
M3/Hr 18.24 16.75 15.33 13.97 12.67 12.67 11.43 10.26 9.15 8.11 7.13 6.21 5.35 4.56 3.83 3.17 2.57 2.03 1.55 1.14
L/Sec. 5.07 4.65 4.26 3.88 3.52 3.52 3.18 2.85 2.54 2.25 1.98 1.72 1.49 1.27 1.06 0.88 0.71 0.56 0.43 0.32 26
M3/Hr 21.89 20.10 18.39 16.76 15.20 15.20 13.72 12.31 10.98 9.73 8.55 7.45 6.42 5.47 4.60 3.80 3.08 2.43 1.86 1.37
L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. 6.08 25.54 7.09 30.65 8.51 5.59 23.45 6.52 28.15 7.82 5.11 21.46 5.96 25.75 7.15 4.66 19.55 5.43 23.46 6.52 4.22 17.74 4.93 21.28 5.91 4.22 17.74 4.93 21.28 5.91 3.81 16.01 4.45 19.21 5.34 3.42 14.37 3.99 17.24 4.79 3.05 12.81 3.56 15.38 4.27 2.70 11.35 3.15 13.62 3.78 2.38 9.98 2.77 11.97 3.33 2.07 8.69 2.41 10.43 2.90 1.78 7.49 2.08 8.99 2.50 1.52 6.38 1.77 7.66 2.13 1.28 5.36 1.49 6.44 1.79 1.06 4.43 1.23 5.32 1.48 0.86 3.59 1.00 4.31 1.20 0.68 2.84 0.79 3.41 0.95 0.52 2.17 0.60 2.61 0.72 0.38 1.60 0.44 1.92 0.53 31 37 44
Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
60T-3 Triplex Plunger Pump Specifications
5/8" x 5/16 KEYWAY
2.250
3 7/8" (USEABLE SHAFT EXT.)
DIA.
2.249
SUCTION & DISCHARGE CONNECTIONS MAY BE
23
9/1 6
MADE AT EITHER END
3/ 4
17
11/ 16
"C"/2
9
1/ 5 2
"C"
18
1/ 5 2
9
3.000 2.999
DIA.
5 1/8" (USEABLE SHAFT EXT.)
7/8" DIA. HOLE THRU
3/4" x 3/8" KEYWAY
4 PLACES, AS SHOWN
1 1/2" N.P.T. (TYP. BOTH SIDES) DISCHARGE
6
7/ 8
5
1/ 4
"B"
1
7/ 8
15
5/ 8
"A"
CENTERLINE
SUCTION 1
CENTERLINE
2" STD. PIPE TAP 5/ 8
(CRADLE DRAIN)
6
30 3/4" STD. PIPE TAP
1/ 2
7 (POWER END OIL DRAIN)
"D"
Pump Size: maximum plunger size x stroke length in.(mm): 3 x 3 (76.2 x 76.2) Rated bhp at 500 rpm (kw): 60 (44.74) Rated plunger load, pounds(Kg): 4750 (2154.5) Maximum discharge pressure: psi(kPa) “L” model: 1500 (10,341) “M” model: 3200 (22,061) “H” model: 5000 (34,470) Crankshaft extension: in.(mm) Diameter: 3 (76.2) Length long side: 5 3/4 (146.2) Length short side: 5 9/16 (141.3) Keyway (width x depth): 3/4 x 3/8 (19.1 x 9.5) Maximum recommended sheave in.(mm): 37.5 (952.5) Minimum recommended sheave in. (mm): 20 (508) For larger sizes: Contact Customer Service Pinion shaft extension, if gear reducer is supplied in.(mm) For belt or chain drive: Contact Customer Service For direct drive: Diameter: 2 1/4 (57.2) Length: 3 7/8 (98.4) Keyway (width x depth): 5/8 x 5/16 (15.9 x 7.9) Accessory gear reduction unit ratios: 2.34:1, 2.77:1, 3.03:1, 3.5:1 Oil Capacity, gallons (L) Crankcase: 2 (7.6) Gear Reducer: 1 (3/8) Weight, pump only on wood shipping skids pounds (Kg): 1145 (519.3) Gear reducer, approximate pounds (Kg): 315 (142.88)
3/ 8
3
"E"
Pump Model 60T-3L Threaded 60T-3L Flanged 60T-3M 60T-3H
Flange Connection Discharge Connection Sizes Suction Connection Sizes 2 (50.8) Int. Pipe Thds. 3 (76.2) Int. Pipe Thds. 2 (50.8) API-2000# RJ 3 (76.2) ANSI-150#FF 1 1/2 (38.1) API-5000#RJ 2 1/2 (63.5) ANSI-150 FF 1 1/4 (31.75) ANSI-2500 RJ 2 1/2 (63.5) ANSI-300 FF
A 4 1/8 4 1/8 4 4
Dimensions in inches (mm) B C D E 4 7/8 20 1/2 33 5/8 43 3/4 4 7/8 20 1/2 33 5/8 44 7/8 4 1/2 22 1/4 33 5/8 43 3/4 4 1/2 22 5/8 33 5/8 44 7/8
60T-3 Triplex Plunger Pump Performance Data PUMP
60T-3L
60T-3M
60T-3H
PUMP
60T-3L
60T-3M
60T-3H
English Units Plunger Plunger BPD Dia. Area per In. Sq. In. RPM 3.000 7.0686 9.4423 2.750 5.9396 7.9341 2.500 4.9087 6.5571 2.250 3.9761 5.3113 2.000 3.1416 4.1966 2.000 3.1416 4.1966 1.750 2.4053 3.2130 1.625 2.0739 2.7704 1.500 1.7671 2.3606 1.375 1.4849 1.9835 1.375 1.4849 1.9835 1.250 1.2272 1.6393 1.125 0.9940 1.3278 1.000 0.7854 1.0491 Brake Horsepower Required
GPM per RPM 0.2754 0.2314 0.1912 0.1549 0.1224 0.1224 0.0937 0.0808 0.0688 0.0579 0.0579 0.0478 0.0387 0.0306
Metric Units Plunger Plunger Dia. Area mm cm2 76 45.604 70 38.320 64 31.669 57 25.652 51 20.268 51 20.268 44 15.518 41 13.380 38 11.401 35 9.580 35 9.580 32 7.917 29 6.413 25 5.067 Kilowatts Required
L/Sec. per RPM 0.0174 0.0146 0.0121 0.0098 0.0077 0.0077 0.0059 0.0051 0.0043 0.0036 0.0036 0.0030 0.0024 0.0019
M3/Hr per RPM 0.0625 0.0526 0.0434 0.0352 0.0278 0.0278 0.0213 0.0184 0.0156 0.0131 0.0131 0.0109 0.0088 0.0069
200 RPM Max. Press. PSI 672 800 968 1195 1500 1512 1975 2290 2688 3200 3200 3871 4779 5000
BPD GPM 1889 55.1 1587 46.3 1312 38.2 1063 31.0 840 24.5 840 24.5 643 18.7 555 16.2 473 13.8 397 11.6 397 11.6 328 9.6 266 7.7 210 6.1 25.0
200 RPM Max. Press. kPa M3/Hr L/Sec. 4633 12.51 3.47 5514 10.51 2.92 6672 8.69 2.41 8237 7.04 1.95 10342 5.56 1.54 10425 5.56 1.54 13616 4.26 1.18 15791 3.67 1.02 18533 3.13 0.87 22063 2.63 0.73 22063 2.63 0.73 26687 2.17 0.60 32947 1.76 0.49 34474 1.39 0.39 18.6
300 RPM
BPD 2833 2381 1968 1594 1259 1259 964 832 709 596 596 492 399 315
350 RPM
GPM 82.6 69.4 57.4 46.5 36.7 36.7 28.1 24.2 20.7 17.4 17.4 14.3 11.6 9.2 37.0
BPD 3305 2777 2295 1859 1469 1469 1125 970 827 695 695 574 465 368
GPM 96.4 81.0 66.9 54.2 42.8 42.8 32.8 28.3 24.1 20.2 20.2 16.7 13.6 10.7 43.0
300 RPM
350 RPM
M3/Hr L/Sec. 18.76 5.21 15.77 4.38 13.03 3.62 10.55 2.93 8.34 2.32 8.34 2.32 6.38 1.77 5.51 1.53 4.69 1.30 3.94 1.09 3.94 1.09 3.26 0.90 2.64 0.73 2.08 0.58 27.6
M3/Hr L/Sec. 21.89 6.08 18.39 5.11 15.20 4.22 12.31 3.42 9.73 2.70 9.73 2.70 7.45 2.07 6.42 1.78 5.47 1.52 4.60 1.28 4.60 1.28 3.80 1.06 3.08 0.86 2.43 0.68 32.1
400 RPM
BPD 3777 3174 2623 2125 1679 1679 1286 1109 945 794 794 656 532 420
GPM 110.2 92.6 76.5 62.0 49.0 49.0 37.5 32.3 27.5 23.1 23.1 19.1 15.5 12.2
450 RPM
BPD 4250 3571 2951 2391 1889 1889 1446 1247 1063 893 893 738 598 473
GPM 123.9 104.1 86.1 69.7 55.1 55.1 42.2 36.4 31.0 26.0 26.0 21.5 17.4 13.8
500 RPM
BPD 4722 3968 3279 2656 2099 2099 1607 1386 1181 992 992 820 664 525
GPM 137.7 115.7 95.6 77.5 61.2 61.2 46.9 40.4 34.4 28.9 28.9 23.9 19.4 15.3
48
54
60
400 RPM
450 RPM
500 RPM
M3/Hr 25.02 21.02 17.37 14.07 11.12 11.12 8.51 7.34 6.25 5.26 5.26 4.34 3.52 2.78
L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. 6.95 28.14 7.82 31.27 8.69 5.84 23.65 6.57 26.28 7.30 4.83 19.54 5.43 21.72 6.03 3.91 15.83 4.40 17.59 4.89 3.09 12.51 3.47 13.90 3.86 3.09 12.51 3.47 13.90 3.86 2.36 9.58 2.66 10.64 2.96 2.04 8.26 2.29 9.18 2.55 1.74 7.04 1.95 7.82 2.17 1.46 5.91 1.64 6.57 1.82 1.46 5.91 1.64 6.57 1.82 1.21 4.89 1.36 5.43 1.51 0.98 3.96 1.10 4.40 1.22 0.77 3.13 0.87 3.47 0.97 35.8 40 45
Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. Below 200 RPM External Auxiliary lubrication system required The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
80T-3 Triplex Plunger Pump 5/8" x 5/16" KEYWAY
2.250 2.249
Specifications
3 7/8" (USEABLE SHAFT EXT.)
DIA.
23 9/16
SUCTION & DISCHARGE CONNECTIONS MAY BE MADE AT EITHER END
17 11/16
"C" / 2
9
5 1/2
18
"C"
5 1/2
9 3/4
7/8" DIA. HOLE THRU 4 PLACES, AS SHOWN 3.000 2.999
DIA.
5 1/8" (USEABLE SHAFT EXT.)
3/4" x 3/8" KEYWAY
1 1/2" N.P.T. (TYP. BOTH SIDES) DISCHARGE "A" "B"
1"
6 7/8
5 1/4
15 5/8
1 7/8
CENTERLINE
SUCTION CENTERLINE
2" STD. PIPE TAP (CRADLE DRAIN)
1 7/8
6 5/8 30
3 3/8
7 1/2
"D"
Pump Size (maximum plunger size x stroke length in.(mm): 3 3/8 x 3 (85.7 x 76.2) Rated bhp at 500 rpm (kw): 80 (59.65) Rated plunger load, pounds(Kg): 6336 (2874) Maximum discharge pressure: psi(kPa) “L” model: 2016 (13,901) “M” model: 4267 (29,420) “H” model: 5161 (35,598) Crankshaft extension: in.(mm) Diameter: 3 (76.2) Length long side: 5 1/8 (130.2) Length short side: 5 9/16 (141.3) Keyway (width x depth): 3/4 x 3/8 (19.1 x 9.5) Maximum recommended sheave in.(mm): 37.5 (952.5) Minimum recommended sheave in.(mm): 20 (508) For larger sizes: Contact Customer Service Pinion shaft extension, if gear reducer is supplied in.(mm) For belt or chain drive: Contact Customer Service For direct drive: Diameter: 2 1/4 (57.2) Length: 3 7/8 (98.4) Keyway (width x depth): 5/8 x 5/16 (15.9 x 7.9) Accessory gear reduction unit ratios: 2.34:1, 2.77:1, 3.03:1, 3.5:1 Oil Capacity, gallons (L) Crankcase: 2 (7.6) Gear Reducer: 1 (3.8) Weight, pump only on wood shipping skids pounds (Kg): 1195 (542.0) Gear reducer, approximate pounds (Kg): 315 (142.88)
"E" 3/4" STD. PIPE TAP (POWER END OIL DRAIN)
Pump Type
Flange Connections Discharge Connection Sizes Suction Connection Sizes 80T-3L(Flanged) 2” API-2000# RJ 3” ANSI-150# FF 80T-3L(Threaded) 2” N.P.T. 3” N.P.T. 80T-3M 1 1/2” API-5000# RJ 2 1/2” ANSI-150# FF 80T-3H 1 1/4” ANSI-2500# RJ 2 1/2” ANSI-300# FF
A 4 1/8 4 1/8 4 4
Dimensions in inches (mm) B C D E 4 7/8 22 1/2 34 5/8 45 7/8 4 7/8 20 1/2 34 5/8 44 3/4 4 1/2 22 1/4 34 5/8 44 3/4 4 1/2 22 5/8 34 5/8 45 7/8
80T-3 Triplex Plunger Pump Performance Data PUMP
80T-3L
80T-3M
80T-3H
PUMP
80T-3L
80T-3M
80T-3H
English Units Plunger Plunger BPD Dia. Area per In. Sq. In. RPM 3.375 8.9462 11.9503 3.250 8.2958 11.0815 3.000 7.0686 9.4423 2.750 5.9396 7.9341 2.500 4.9087 6.5571 2.250 3.9761 5.3113 2.000 3.1416 4.1966 2.000 3.1416 4.1966 1.750 2.4053 3.2130 1.625 2.0739 2.7704 1.500 1.7671 2.3606 1.375 1.4849 1.9835 1.375 1.4849 1.9835 1.250 1.2272 1.6393 Brake Horsepower Required
GPM per RPM 0.3486 0.3232 0.2754 0.2314 0.1912 0.1549 0.1224 0.1224 0.0937 0.0808 0.0688 0.0579 0.0579 0.0478
Metric Units Plunger Plunger Dia. Area mm cm2 86 57.717 83 53.521 76 45.604 70 38.320 64 31.669 57 25.652 51 20.268 51 20.268 44 15.518 41 13.380 38 11.401 35 9.580 35 9.580 32 7.917 Kilowatts Required
L/Sec. per RPM 0.0220 0.0204 0.0174 0.0146 0.0121 0.0098 0.0077 0.0077 0.0059 0.0051 0.0043 0.0036 0.0036 0.0030
M3/Hr per RPM 0.0792 0.0734 0.0625 0.0526 0.0434 0.0352 0.0278 0.0278 0.0213 0.0184 0.0156 0.0131 0.0131 0.0109
200 RPM Max. Press. PSI 708 764 896 1067 1500 1594 2017 2017 2634 3055 3584 4267 4267 5161
Max. Press. kPa 4883 5266 6180 7355 10342 10987 13906 13906 18162 21064 24711 29420 29420 35584
BPD GPM 2391 69.7 2217 64.6 1889 55.1 1587 46.3 1312 38.2 1063 31.0 840 24.5 840 24.5 643 18.7 555 16.2 473 13.8 397 11.6 397 11.6 328 9.6 32.0
300 RPM
BPD 3586 3325 2833 2381 1968 1594 1259 1259 964 832 709 596 596 492
350 RPM
GPM 104.6 97.0 82.6 69.4 57.4 46.5 36.7 36.7 28.1 24.2 20.7 17.4 17.4 14.3 48.0
BPD 4183 3879 3305 2777 2295 1859 1469 1469 1125 970 827 695 695 574
GPM 122.0 113.1 96.4 81.0 66.9 54.2 42.8 42.8 32.8 28.3 24.1 20.2 20.2 16.7 56.0
200 RPM
300 RPM
350 RPM
M3/Hr L/Sec. 15.83 4.40 14.68 4.08 12.51 3.47 10.51 2.92 8.69 2.41 7.04 1.95 5.56 1.54 5.56 1.54 4.26 1.18 3.67 1.02 3.13 0.87 2.63 0.73 2.63 0.73 2.17 0.60 23.9
M3/Hr L/Sec. 23.75 6.60 22.02 6.12 18.76 5.21 15.77 4.38 13.03 3.62 10.55 2.93 8.34 2.32 8.34 2.32 6.38 1.77 5.51 1.53 4.69 1.30 3.94 1.09 3.94 1.09 3.26 0.90 35.8
M3/Hr L/Sec. 27.70 7.70 25.69 7.14 21.89 6.08 18.39 5.11 15.20 4.22 12.31 3.42 9.73 2.70 9.73 2.70 7.45 2.07 6.42 1.78 5.47 1.52 4.60 1.28 4.60 1.28 3.80 1.06 41.8
400 RPM
BPD 4781 4433 3777 3174 2623 2125 1679 1679 1286 1109 945 794 794 656
GPM 139.4 129.3 110.2 92.6 76.5 62.0 49.0 49.0 37.5 32.3 27.5 23.1 23.1 19.1 64
400 RPM
M3/Hr 31.66 29.36 25.02 21.02 17.37 14.07 11.12 11.12 8.51 7.34 6.25 5.26 5.26 4.34
450 RPM
BPD 5378 4987 4250 3571 2951 2391 1889 1889 1446 1247 1063 893 893 738
GPM 156.8 145.4 123.9 104.1 86.1 69.7 55.1 55.1 42.2 36.4 31.0 26.0 26.0 21.5
500 RPM
BPD 5976 5541 4722 3968 3279 2656 2099 2099 1607 1386 1181 992 992 820
GPM 174.3 161.6 137.7 115.7 95.6 77.5 61.2 61.2 46.9 40.4 34.4 28.9 28.9 23.9
72
80
450 RPM
500 RPM
L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. 8.80 35.62 9.90 39.58 11.00 8.16 33.03 9.18 36.70 10.20 6.95 28.14 7.82 31.27 8.69 5.84 23.65 6.57 26.28 7.30 4.83 19.54 5.43 21.72 6.03 3.91 15.83 4.40 17.59 4.89 3.09 12.51 3.47 13.90 3.86 3.09 12.51 3.47 13.90 3.86 2.36 9.58 2.66 10.64 2.96 2.04 8.26 2.29 9.18 2.55 1.74 7.04 1.95 7.82 2.17 1.46 5.91 1.64 6.57 1.82 1.46 5.91 1.64 6.57 1.82 1.21 4.89 1.36 5.43 1.51 47.7 54 60
Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. For operations below 200 RPM, auxiliary lubrication system required. Not all plunger sizes are shown. Contact National-Oilwell for additional information. 3-3/8 & 3-1/4” Plungers require spherical valves The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
100T-4 Triplex Plunger Pump 5/8 "x 5/16 " KEYWAY 6 1/2
9 3/8
Specifications
2.375 DIA. 2.374
24 7/16
8 1/2
11 7/16
"C"
58 1/4
22 1/2
6 1/2
PLUNGER NO. 1
8 5/16
"C/2"
6 1/2
11 1/4
PLUNGER NO. 2
PLUNGER NO. 3
4 PUMP MOUNTING HOLES 7/8 " DIA. THRU AS SHOWN
7/8 "x 7/16 " KEYWAY SHAFT EXTENSION FOR DIRECT DRIVE
3.750 DIA. 3.749
1 1/2 " STD. PIPE TAP MUD TRAP DRAIN
1 1/2 " STD. PIPE TAP CRADLE DRAIN TYPICAL BOTH SIDES
"B"
4 1/2
6"
9"
10 7/8
19 5/8
"A"
DISCHARGE CENTERLINE
SUCTION CENTERLINE
1" NPT (POWER END OIL DRAIN)
2 7/8
Pump Size maximum plunger size x stroke length in.(mm): 3 3/8 x 4 (85.7 x 101.6) Rated bhp at 450 rpm (kw): 100 (75) Rated plunger load pounds(Kg): 6595 (2991.4) Maximum discharge pressure: psi(kPa) “L” model: 1659 (11,4440) “M” model: 3180 (21,939) “H” model: 5000 (34,474) Crankshaft extension: in.(mm) Diameter: 3 3/4 (95.25) Length long side: 8 1/2 (215.9) Length short side: 8 5/16 (211.38) Keyway (width x depth): 7/8 x 7/16 (22.2 x 11.1) Maximum recommended sheave in.(mm): 44 (1118) Minimum recommended sheave in.(mm): 24 (610) For larger sizes: Contact Factory Pinion shaft extension, if gear reducer is supplied in.(mm) For belt or chain drive: Contact Factory For direct drive: Diameter: 2 3/8 (60.33) Length: 6 1/2 (165.10) Keyway (width x depth): 5/8 x 5/16 (15.9 x 7.9) Accessory gear reduction unit ratios: 2.60:1, 3.15:1, 3.42:1, 3.89:1, 4.27:1 Oil Capacity gallons (L) Crankcase: 5.5 (20.8) Gear Reducer: 3 (11.40) Weight, pump only on wood shipping skids pounds (Kg): 2300 (1043.3) Gear reducer, approximate pounds (Kg): 500 (226.8)
SUCTION & DISCHARGE CONNECTIONS MAY BE MADE AT EITHER END.
16 1/8 32 13/16
6" 4 3/4
"D" 2" STD. PIPE TAP CRADLE DRAIN
33 1/8 "E"
Pump Model 100T-4L 100T-4M 100T-4H
Flange Connection Discharge Connection Sizes Suction Connection Sizes 2 1/2 (63.5) API-2000 RJ 5 (127) ANSI-150 FF 1 1/2 (38.1) API-5000 RJ 3 (76.2) ANSI-150 FF 1 1/2 (38.1) ANSI-2500 RJ 3 (76.2) ANSI-300 FF
A 5 5/8 4 3/4 4 3/4
Dimensions in inches (mm) B C D E 6 7/8 25 1/2 41 5/8 57 3/8 5 1/4 23 3/4 40 7/8 54 3/8 5 1/4 25 1/2 40 1/2 55 3/8
100T-4 Triplex Plunger Pump Performance Data PUMP
100T-4L
100T-4M
100T-4H
PUMP
100T-4L
100T-4M
100T-4H
English Units Plunger Plunger BPD Dia. Area per In. Sq. In. RPM 3.375 8.9462 15.9338 3.250 8.2958 14.7754 3.000 7.0686 12.5897 2.750 5.9396 10.5788 2.500 4.9087 8.7428 2.250 3.9761 7.0817 2.125 3.5466 6.3167 2.000 3.1416 5.5954 1.875 2.7612 4.9178 1.750 2.4053 4.2840 1.625 2.0739 3.6938 1.750 2.4053 4.2840 1.625 2.0739 3.6938 1.500 1.7671 3.1474 1.375 1.4849 2.6447 1.250 1.2272 2.1857 Brake Horsepower Required
GPM per RPM 0.4647 0.4309 0.3672 0.3085 0.2550 0.2065 0.1842 0.1632 0.1434 0.1249 0.1077 0.1249 0.1077 0.0918 0.0771 0.0637
200 RPM
Metric Units Plunger Plunger Dia. Area mm cm2 86 57.717 83 53.521 76 45.604 70 38.320 64 31.669 57 25.652 54 22.881 51 20.268 48 17.814 44 15.518 41 13.380 44 15.518 41 13.380 38 11.401 35 9.580 32 7.917 Kilowatts Required
L/Sec. per RPM 0.0293 0.0272 0.0232 0.0195 0.0161 0.0130 0.0116 0.0103 0.0090 0.0079 0.0068 0.0079 0.0068 0.0058 0.0049 0.0040
Max. Press. PSI 737 795 933 1110 1500 1659 1860 2099 2388 2742 3180 2742 3180 3732 4441 5000
BPD GPM 3187 92.9 2956 86.2 2518 73.4 2116 61.7 1749 51.0 1417 41.3 1264 36.8 1120 32.6 984 28.7 857 25.0 739 21.5 857 25.0 739 21.5 630 18.4 529 15.4 438 12.7 45.0
200 RPM M3/Hr per RPM 0.1055 0.0979 0.0834 0.0701 0.0579 0.0469 0.0418 0.0371 0.0326 0.0284 0.0245 0.0284 0.0245 0.0208 0.0175 0.0145
Max. Press. kPa 5083 5481 6433 7656 10342 11436 12821 14474 16468 18905 21925 18905 21925 25731 30623 34474
M3/Hr L/Sec. 21.11 5.86 19.57 5.44 16.68 4.63 14.01 3.89 11.58 3.22 9.38 2.61 8.37 2.32 7.41 2.06 6.51 1.81 5.68 1.58 4.89 1.36 5.68 1.58 4.89 1.36 4.17 1.16 106.37 3.50 48.26 87.91 33.6
250 RPM
BPD 3984 3694 3148 2645 2186 1771 1580 1399 1230 1071 924 1071 924 787 662 547
GPM 116.2 107.7 91.8 77.1 63.7 51.6 46.1 40.8 35.9 31.2 26.9 31.2 26.9 22.9 19.3 15.9 56.0
250 RPM
300 RPM
BPD 4781 4433 3777 3174 2623 2125 1896 1679 1476 1286 1109 1286 1109 945 794 656
GPM 139.4 129.3 110.2 92.6 76.5 62.0 55.3 49.0 43.0 37.5 32.3 37.5 32.3 27.5 23.1 19.1 67.0
300 RPM
350 RPM
BPD 5577 5172 4407 3703 3060 2479 2211 1959 1722 1500 1293 1500 1293 1102 926 765
GPM 162.7 150.8 128.5 108.0 89.2 72.3 64.5 57.1 50.2 43.7 37.7 43.7 37.7 32.1 27.0 22.3 78
350 RPM
400 RPM
BPD 6374 5911 5036 4232 3498 2833 2527 2239 1968 1714 1478 1714 1478 1259 1058 875
GPM 185.9 172.4 146.9 123.4 102.0 82.6 73.7 65.3 57.4 50.0 43.1 50.0 43.1 36.7 30.9 25.5 89
400 RPM
450 RPM
BPD 7171 6649 5666 4761 3935 3187 2843 2518 2214 1928 1663 1928 1663 1417 1191 984
GPM 209.1 193.9 165.2 138.8 114.7 92.9 82.9 73.4 64.5 56.2 48.5 56.2 48.5 41.3 34.7 28.7 100
450 RPM
M3/Hr L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. 26.39 7.33 31.66 8.80 36.94 10.26 42.22 11.73 47.49 13.19 24.47 6.80 29.36 8.16 34.25 9.52 39.15 10.88 44.04 12.23 20.85 5.79 25.02 6.95 29.19 8.11 33.36 9.27 37.53 10.42 17.52 4.87 21.02 5.84 24.53 6.81 28.03 7.79 31.53 8.76 14.48 4.02 17.37 4.83 20.27 5.63 23.16 6.44 26.06 7.24 11.73 3.26 14.07 3.91 16.42 4.56 18.76 5.21 21.11 5.86 10.46 2.91 12.55 3.49 14.64 4.07 16.74 4.65 18.83 5.23 9.27 2.57 11.12 3.09 12.97 3.60 14.83 4.12 16.68 4.63 8.14 2.26 9.77 2.71 11.40 3.17 13.03 3.62 14.66 4.07 7.09 1.97 8.51 2.36 9.93 2.76 11.35 3.15 12.77 3.55 6.12 1.70 7.34 2.04 8.56 2.38 9.79 2.72 11.01 3.06 7.09 1.97 8.51 2.36 9.93 2.76 11.35 3.15 12.77 3.55 6.12 1.70 7.34 2.04 8.56 2.38 9.79 2.72 11.01 3.06 5.21 1.45 6.25 1.74 7.30 2.03 8.34 2.32 9.38 2.61 132.96 4.38 159.55 5.26 186.15 6.13 212.74 7.01 239.33 7.88 60.33 109.89 72.40 131.86 84.46 153.84 96.53 175.82 108.59 197.79 41.8 50.0 58.0 66 75
Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. For operations below 200 RPM, auxiliary lubrication system required. Not all plunger sizes are shown. Contact National-Oilwell for additional information. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
101T-4 Triplex Plunger Pump Specifications
DIRECTION OF ROTATION 18.25
14.44 8.00 16.00
C
C
6.00 TYP 12.19
19.50 ÿ.75 TYP 4 PLACES
.750 X .375 KEYWAY 5.125 LONG
3.000 ÿ2.999
"101T-4H" ONLY
F
10.33
F A
A
B
B
10.00
1.00 TYP 5.25 8.81
21.75 24.25 D E
Pump Model 101T-4L 101T-4M 101T-4H
Flange Connections Discharge Connection Sizes Suction Connection Sizes 3” - 600# ANSI FF 6” - 150# ANSI FF 2” - 1500# ANSI FF 4” - 300# ANSI FF 2” - 2500# ANSI RJ 3” - 2500# ANSI RJ
D E
A 4 5/8 5 1/16 5 1/8
33.38
Pump Size: maximum plunger size x stroke length, in.(mm): 3.375 x 4.500 (85.725 x 114.3) Rated BHP (kW) at 400 RPM: 100 (75) Rated plunger load, pounds (kg): 6600 (2994) Maximum discharge pressure: psi (kPa) “L” model: 1220 (8408) “M” model: 2744 (18919) “H” model: 5378 (37081) Crankshaft extension: Diameter, in.(mm): 3.000 (95.25) Length, in.(mm): 5.13 (130.3) Keyway width x depth, in.(mm): 3/4 x 3/8 (19.1 x 9.5) Maximum recommended sheave diameter, in.(mm): 50 (1270) For larger sizes: Contact Factory Pinion shaft extension, if gear reducer is supplied, in.(mm) For belt or chain drive: N/A For direct drive: Diameter: 2.000 (50.8) Length: 4.25 (108.0) Keyway width x depth: 1/2 x 1/4 (12.70 x 6.35) Accessory gear reduction unit: 3.00:1, 3.12:1, 3.23:1, 3.36:1, 3.49:1, 3.62:1, 3.78:1, 3.94:1, 4.11:1, 4.29:1, 4.48:1, 4.69:1, 4.93:1, 5.17:1 Oil Capacity, gallons (L) Crankcase: 6 (22.71) Gear Reducer - varies with ratio: 1.25 to 1.50 (4.73 to 5.68) Weight, pump only on wood shipping skids, pounds (kg) “L” model: 1740 (649.4) “M” model: 1600 (597.2) “H” model: 1820 (679.3) Standard Materials for Fluid Ends: “L” model Cast Duplex Stainelss Steel Cast Nickel-Aluminium-Bronze Forged/Plate Carbon Steel “M” model Cast Duplex Stainless Steel Cast Nickel-Aluminium-Bronze Forged/Plate Carbon Steel “H” model Forged/Plate Carbon Steel
Dimensions (Inches) B C D E 7 7/8 21 33 3/4 48 3/8 6 3/16 21 33 3/8 47 9/16 6 1/8 30 1/8 36 3/4 52 7/16
F 9 3/8 9 11 7/8
101T-4 Triplex Plunger Pump Performance Data PUMP
101T-4L (T100-4)
101T-4M (T100-3)
101T-4H (T100-2)
PUMP
101T-4L (T100-4)
101T-4M (T100-3)
101T-4H (T100-2)
English Units Plunger Plunger BPD Dia. Area per In. Sq. In. RPM 3.375 8.9462 17.9255 3.250 8.2958 16.6223 3.125 7.6699 15.3682 3.000 7.0686 14.1634 2.875 6.4918 13.0077 2.750 5.9396 11.9012 2.625 5.4119 10.8438 2.500 4.9087 9.8357 2.375 4.4301 8.8767 2.250 3.9761 7.9669 2.125 3.5466 7.1063 2.000 3.1416 6.2948 1.875 2.7612 5.5326 1.750 2.4053 4.8195 1.625 2.0739 4.1556 1.500 1.7671 3.5408 1.375 1.4849 2.9753 1.250 1.2272 2.4589 Brake Horsepower Required
GPM per RPM 0.5228 0.4848 0.4482 0.4131 0.3794 0.3471 0.3163 0.2869 0.2589 0.2324 0.2073 0.1836 0.1614 0.1406 0.1212 0.1033 0.0868 0.0717
Metric Units Plunger Plunger Dia. Area mm cm2 86 57.717 83 53.521 79 49.483 76 45.604 73 41.883 70 38.320 67 34.915 64 31.669 60 28.581 57 25.652 54 22.881 51 20.268 48 17.814 44 15.518 41 13.380 38 11.401 35 9.580 32 7.917 Kilowatts Required
L/Sec. per RPM 0.0330 0.0306 0.0283 0.0261 0.0239 0.0219 0.0200 0.0181 0.0163 0.0147 0.0131 0.0116 0.0102 0.0089 0.0076 0.0065 0.0055 0.0045
M3/Hr per RPM 0.1187 0.1101 0.1018 0.0938 0.0862 0.0788 0.0718 0.0651 0.0588 0.0528 0.0471 0.0417 0.0366 0.0319 0.0275 0.0235 0.0197 0.0163
50 RPM Max. Press. PSI 738 796 861 934 1017 1111 1220 1345 1490 1660 1861 2101 2390 2744 3182 3735 4445 5378
BPD 897 832 769 709 651 596 543 492 444 399 356 315 277 241 208 178 149 123
GPM 26.1 24.2 22.4 20.7 19.0 17.4 15.8 14.3 12.9 11.6 10.4 9.2 8.1 7.0 6.1 5.2 4.3 3.6 13
150 RPM
BPD 2689 2494 2306 2125 1952 1786 1627 1476 1332 1196 1066 945 830 723 624 532 447 369
250 RPM
GPM 78.4 72.7 67.2 62.0 56.9 52.1 47.4 43.0 38.8 34.9 31.1 27.5 24.2 21.1 18.2 15.5 13.0 10.8
BPD 4482 4156 3843 3541 3252 2976 2711 2459 2220 1992 1777 1574 1384 1205 1039 886 744 615
38
50 RPM 150 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 5087 5.9 1.6 17.8 4.9 5485 5.5 1.5 16.5 4.6 5933 5.1 1.4 15.3 4.2 6438 4.7 1.3 14.1 3.9 7010 4.3 1.2 12.9 3.6 7661 3.9 1.1 11.8 3.3 8408 3.6 1.0 10.8 3.0 9270 3.3 0.90 9.8 2.7 10272 2.9 0.82 8.8 2.5 11445 2.6 0.73 7.9 2.2 12831 2.4 0.65 7.1 2.0 14485 2.1 0.58 6.3 1.7 16481 1.8 0.51 5.5 1.5 18919 1.6 0.44 4.8 1.3 21942 1.4 0.38 4.1 1.1 25751 1.2 0.33 3.5 1.0 30646 1.0 0.27 3.0 0.82 37081 0.8 0.23 2.4 0.68 10 28
GPM 130.7 121.2 112.1 103.3 94.8 86.8 79.1 71.7 64.7 58.1 51.8 45.9 40.3 35.1 30.3 25.8 21.7 17.9
300 RPM
BPD 5378 4987 4611 4250 3903 3571 3254 2951 2664 2391 2132 1889 1660 1446 1247 1063 893 738
GPM 156.8 145.4 134.5 123.9 113.8 104.1 94.9 86.1 77.7 69.7 62.2 55.1 48.4 42.2 36.4 31.0 26.0 21.5
350 RPM
BPD 6274 5818 5379 4958 4553 4166 3796 3443 3107 2789 2488 2204 1937 1687 1455 1240 1042 861
GPM 183.0 169.7 156.9 144.6 132.8 121.5 110.7 100.4 90.6 81.3 72.5 64.3 56.5 49.2 42.4 36.1 30.4 25.1
63
75
88
250 RPM
300 RPM
350 RPM
M3/Hr 29.7 27.5 25.4 23.5 21.5 19.7 18.0 16.3 14.7 13.2 11.8 10.4 9.2 8.0 6.9 5.9 4.9 4.1
L/Sec. 8.2 7.6 7.1 6.5 6.0 5.5 5.0 4.5 4.1 3.7 3.3 2.9 2.5 2.2 1.9 1.6 1.4 1.1
M3/Hr 35.6 33.0 30.5 28.1 25.8 23.6 21.5 19.5 17.6 15.8 14.1 12.5 11.0 9.6 8.3 7.0 5.9 4.9
47
400 RPM
BPD 7171 6649 6148 5666 5204 4761 4338 3935 3551 3187 2843 2518 2214 1928 1663 1417 1191 984
GPM 209.1 193.9 179.3 165.2 151.8 138.8 126.5 114.7 103.6 92.9 82.9 73.4 64.5 56.2 48.5 41.3 34.7 28.7 100
400 RPM
L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. 9.9 41.6 11.5 47.5 13.2 9.2 38.5 10.7 44.0 12.2 8.5 35.6 9.9 40.7 11.3 7.8 32.8 9.1 37.5 10.4 7.2 30.2 8.4 34.5 9.6 6.6 27.6 7.7 31.5 8.8 6.0 25.1 7.0 28.7 8.0 5.4 22.8 6.3 26.1 7.2 4.9 20.6 5.7 23.5 6.5 4.4 18.5 5.1 21.1 5.9 3.9 16.5 4.6 18.8 5.2 3.5 14.6 4.1 16.7 4.6 3.1 12.8 3.6 14.7 4.1 2.7 11.2 3.1 12.8 3.5 2.3 9.6 2.7 11.0 3.1 2.0 8.2 2.3 9.4 2.6 1.6 6.9 1.9 7.9 2.2 1.4 5.7 1.6 6.5 1.8 56 65 75
Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
103Q-3 Quintuplex Plunger Pump Specifications
18.63
C/2 10.50
C
21.00
15.94
5.50 ÿ.75 TYP 4 PLACES
ÿ
2.500 2.499
.625 x .313 KEYWAY 5.250 LONG
DISCHARGE CONNECTION
F
A
19.13 .75
B
8.75
.75 4.25 8.00
SUCTION CONNECTION
18.88 D
E
Pump Model 103Q-3L 103Q-3M 103Q-3MS 103Q-3H
Flange Connections Discharge Connection Sizes Suction Connection Sizes 3 (76.2)-600# ANSI FF 6 (152.4)-150# ANSI FF 2 (50.8)-1500# ANSI FF 3 (76.2)-300# ANSI FF 2 (50.8) NPT-11 1/2 THDS 3 (76.2) NPT-11 1/2 THDS 1 (25.4) NPT-11 1/2 THDS 1 1/2 (38.1) NPT-11 1/2 THDS
A 5 3 7/16 4 9/16 3 7/8
Pump Size: maximum plunger size x stroke length, in.(mm): 3.000 x 3.500 (76.2 x 88.9) Rated BHP (kW) at 435 RPM: 102 (76) Rated plunger load, pounds (kg): 4760 (2159) Maximum discharge pressure: psi (kPa) “L” model: 970 (6686) “M” model: 2295 (15825) “MS” model: 4789 (33017) “H” model: 10000 (68948) Crankshaft extension: Diameter, in.(mm): 2.500 (63.5) Length : 5.250 (133.35) Keyway (width x depth): 5/8 x 5/16 (15.875 x 7.938) Maximum recommended sheave in.(mm): 38 (965.2) For larger sizes: Contact Factory Pinion shaft extension, if gear reducer is supplied, in.(mm) For belt or chain drive: N/A For direct drive: Diameter: 2.000 (50.8) Length: 4.250 (108.0) Keyway width x depth: 1/2 x 1/4 (12.70 x 6.35) Accessory gear reduction unit: 3.00:1, 3.12:1, 3.23:1, 3.36:1, 3.49:1, 3.62:1, 3.78:1, 3.94:1, 4.11:1, 4.29:1, 4.48:1, 4.69:1, 4.93:1, 5.17:1 Oil Capacity, gallons (L) Crankcase: 5 (18.93) Gear Reducer - varies with ratio: 1.25 to 1.50 (4.73 to 5.68) Weight, pump only on wood shipping skids, pounds (kg) “L” model: 1620 (735) “M” model: 1450 (658) “MS” model: 1600 (726) “H” model: 1700 (771) Standard Materials for Fluid Ends: “L” model Cast Ductile Iron Cast Nickel-Aluminum-Bronze Cast Duplex Stainless Steel Forged/Plate Carbon Steel “M” model Cast Ductile Iron, Cast Nickel-Aluminum-Bronze Cast Duplex Stainless Steel Forged/Plate Carbon Steel “MS” model Forged Nickel-Aluminum-Bronze Forged/Plate Carbon Steel Forged 316 Stainless Steel “H” model Forged 15-5 Stainless Steel
Dimensions (Inches) B C D 7 1/4 29 28 5 3/4 30 27 3/16 5 3/4 26 1/2 26 7/8 4 3/8 28 25 3/4
E 41 5/8 40 7/8 40 1/8 39 7/8
F 9 7/8 8 1/8 8 7/8 7 3/4
103Q-3 Quintuplex Plunger Pump Performance Data PUMP
103Q-3L (Q3115AL)
103Q-3M (Q3115AM)
103Q-3MS (Q3115MS)
103Q-3H (Q3115H)
PUMP
103Q-3L (Q3115AL)
103Q-3M (Q3115AM)
103Q-3MS (Q3115MS)
103Q-H (Q3115H)
English Units Plunger Plunger BPD Dia. Area per In. Sq. In. RPM 3.000 7.0686 18.3599 2.875 6.4918 16.8618 2.750 5.9396 15.4274 2.625 5.4119 14.0568 2.500 4.9087 12.7500 2.500 4.9087 12.7500 2.375 4.4301 11.5068 2.250 3.9761 10.3275 2.125 3.5466 9.2118 2.000 3.1416 8.1600 1.875 2.7612 7.1718 1.750 2.4053 6.2475 1.625 2.0739 5.3869 1.500 1.7671 4.5900 1.375 1.4849 3.8569 1.250 1.2272 3.1875 1.125 0.9940 2.5819 1.000 0.7854 2.0400 0.875 0.6013 1.5619 0.750 0.4418 1.1475 Brake Horsepower Required
GPM per RPM 0.5355 0.4918 0.4500 0.4100 0.3719 0.3719 0.3356 0.3012 0.2687 0.2380 0.2092 0.1822 0.1571 0.1339 0.1125 0.0930 0.0753 0.0595 0.0456 0.0335
Metric Units Plunger Plunger Dia. Area mm cm2 76 45.604 73 41.883 70 38.320 67 34.915 64 31.669 64 31.669 60 28.581 57 25.652 54 22.881 51 20.268 48 17.814 44 15.518 41 13.380 38 11.401 35 9.580 32 7.917 29 6.413 25 5.067 22 3.879 19 2.850 Kilowatts Required
L/Sec. per RPM 0.0338 0.0310 0.0284 0.0259 0.0235 0.0235 0.0212 0.0190 0.0170 0.0150 0.0132 0.0115 0.0099 0.0084 0.0071 0.0059 0.0048 0.0038 0.0029 0.0021
M3/Hr per RPM 0.1216 0.1117 0.1022 0.0931 0.0845 0.0845 0.0762 0.0684 0.0610 0.0540 0.0475 0.0414 0.0357 0.0304 0.0255 0.0211 0.0171 0.0135 0.0103 0.0076
50 RPM Max. Press. PSI 673 733 801 880 970 970 1074 1197 1342 1515 1724 1979 2295 2694 3206 3879 4789 6061 7916 10000
BPD 918 844 772 703 638 638 576 517 461 408 359 313 270 230 193 160 130 102 79 58
GPM 26.8 24.6 22.5 20.5 18.6 18.6 16.8 15.1 13.4 11.9 10.5 9.1 7.9 6.7 5.6 4.6 3.8 3.0 2.3 1.7 12
150 RPM
BPD 2754 2530 2315 2109 1913 1913 1727 1550 1382 1224 1076 938 809 689 579 479 388 306 235 173
250 RPM
GPM 80.3 73.8 67.5 61.5 55.8 55.8 50.3 45.2 40.3 35.7 31.4 27.3 23.6 20.1 16.9 13.9 11.3 8.9 6.8 5.0
BPD 4590 4216 3857 3515 3188 3188 2877 2582 2303 2040 1793 1562 1347 1148 965 797 646 510 391 287
35
50 RPM 150 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 4643 6.1 1.69 18.2 5.07 5055 5.6 1.55 16.8 4.65 5526 5.1 1.42 15.3 4.26 6064 4.7 1.29 14.0 3.88 6686 4.2 1.17 12.7 3.52 6686 4.2 1.17 12.7 3.52 7408 3.8 1.06 11.4 3.18 8254 3.4 0.95 10.3 2.85 9254 3.1 0.85 9.2 2.54 10447 2.7 0.75 8.1 2.25 11886 2.4 0.66 7.1 1.98 13645 2.1 0.57 6.2 1.72 15825 1.8 0.50 5.4 1.49 18572 1.5 0.42 4.6 1.27 22102 1.3 0.35 3.8 1.06 26744 1.1 0.29 3.2 0.88 33017 0.9 0.24 2.6 0.71 41787 0.7 0.19 2.0 0.56 54579 0.5 0.14 1.6 0.43 68948 0.4 0.11 1.1 0.32 9 26
GPM 133.9 123.0 112.5 102.5 93.0 93.0 83.9 75.3 67.2 59.5 52.3 45.6 39.3 33.5 28.1 23.2 18.8 14.9 11.4 8.4
300 RPM
BPD 5508 5059 4629 4218 3825 3825 3453 3099 2764 2448 2152 1875 1617 1377 1158 957 775 612 469 345
GPM 160.6 147.5 135.0 123.0 111.6 111.6 100.7 90.4 80.6 71.4 62.8 54.7 47.1 40.2 33.7 27.9 22.6 17.8 13.7 10.0
350 RPM
BPD 6426 5902 5400 4920 4463 4463 4028 3615 3225 2856 2511 2187 1886 1607 1350 1116 904 714 547 402
GPM 187.4 172.1 157.5 143.5 130.2 130.2 117.5 105.4 94.0 83.3 73.2 63.8 55.0 46.9 39.4 32.5 26.4 20.8 15.9 11.7
59
70
82
250 RPM
300 RPM
350 RPM
M3/Hr 30.4 27.9 25.5 23.3 21.1 21.1 19.1 17.1 15.3 13.5 11.9 10.3 8.9 7.6 6.4 5.3 4.3 3.4 2.6 1.9
L/Sec. 8.45 7.76 7.10 6.47 5.87 5.87 5.29 4.75 4.24 3.75 3.30 2.87 2.48 2.11 1.77 1.47 1.19 0.94 0.72 0.53 44
M3/Hr 36.5 33.5 30.7 27.9 25.3 25.3 22.9 20.5 18.3 16.2 14.3 12.4 10.7 9.1 7.7 6.3 5.1 4.1 3.1 2.3
435 RPM
BPD 7987 7335 6711 6115 5547 5547 5006 4493 4008 3550 3120 2718 2344 1997 1678 1387 1124 888 680 500
GPM 232.9 213.9 195.7 178.3 161.8 161.8 146.0 131.0 116.9 103.5 91.0 79.3 68.3 58.2 48.9 40.4 32.8 25.9 19.8 14.6 102
435 RPM
L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. 10.14 42.6 11.82 52.9 14.70 9.31 39.1 10.86 48.6 13.50 8.52 35.8 9.94 44.5 12.35 7.76 32.6 9.05 40.5 11.25 7.04 29.6 8.21 36.7 10.21 7.04 29.6 8.21 36.7 10.21 6.35 26.7 7.41 33.2 9.21 5.70 23.9 6.65 29.8 8.27 5.09 21.4 5.93 26.5 7.37 4.50 18.9 5.26 23.5 6.53 3.96 16.6 4.62 20.7 5.74 3.45 14.5 4.02 18.0 5.00 2.97 12.5 3.47 15.5 4.31 2.53 10.6 2.96 13.2 3.67 2.13 8.9 2.48 11.1 3.09 1.76 7.4 2.05 9.2 2.55 1.43 6.0 1.66 7.4 2.07 1.13 4.7 1.31 5.9 1.63 0.86 3.6 1.01 4.5 1.25 0.63 2.7 0.74 3.3 0.92 52 61 76
Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
110Q-3 Quintuplex Plunger Pump INTERNAL LUBE PUMP
Specifications
PRESSURE GAUGE
21.75
C/2 10.50
C
21.00
15.94
8.31
ÿ.75 TYP 4 PLACES
.750 x .375 KEYWAY 6.250 LONG ÿ
3.250 3.249
DISCHARGE CONNECTION
F
A
6.63 19.13 .75
B
8.75
15.50 .75 4.25 8.00
SUCTION CONNECTION
18.88 D E
Pump Model 110Q-3L 110Q-3M 110Q-3MS 110Q-3H
Flange Connections Discharge Connection Sizes Suction Connection Sizes 3 (76.2)-600# ANSI FF 6 (152.4)-150# ANSI FF 2 (50.8)-1500# ANSI FF 3 (76.2)-300# ANSI FF 2 (50.8) NPT-11 1/2 THDS 3 (76.2) NPT-11 1/2 THDS 1 (25.4) NPT-11 1/2 THDS 1 1/2 (38.1) NPT-11 1/2 THDS
A 5 3 7/16 4 9/16 3 7/8
Pump Size: maximum plunger size x stroke length, in.(mm): 3.000 x 3.500 (76.2 x 88.9) Rated BHP (kW) at 440 RPM: 110 (82) Rated plunger load, pounds (kg): 5090 (2309) Maximum discharge pressure: psi (kPa) ”L” model: 1037 (7149) ”M” model: 2454 (16922) ”MS” model: 5121 (35306) ”H” model: 10000 (68948) Crankshaft extension: Diameter, in.(mm): 3.250 (82.55) Length, in.(mm): 8.31 (211.1) Keyway width x depth, in.(mm): 3/4 x 3/8 (19.05 x 9.525) Maximum recommended sheave diameter, in.(mm): 38 (965.2) For larger sizes: Contact Factory Pinion shaft extension, if gear reducer is supplied, in.(mm) For belt or chain drive: N/A For direct drive: Diameter: 2.000 (50.8) Length: 4.250 (108.0) Keyway width x depth: 1/2 x 1/4 (12.70 x 6.35) Accessory gear reduction unit: 3.00:1, 3.12:1, 3.23:1, 3.36:1, 3.49:1, 3.62:1, 3.78:1,3.94:1, 4.11:1, 4.29:1, 4.48:1, 4.69:1, 4.93:1, 5.17:1 Oil Capacity, gallons (L) Crankcase: 5 (18.93) Gear Reducer - varies with ratio: 1.25 to 1.50 (4.73 to 5.68) Weight, pump only on wood shipping skids, pounds (kg) ”L” model: 1670 (757) ”M” model: 1500 (680) ”MS” model: 1650 (748) ”H” model: 1750 (794) Standard Materials for Fluid Ends: ”L” model Cast Ductile Iron Cast Nickel-Aluminum-Bronze Cast Duplex Stainless Steel Cast/Forged/Plate Carbon Steel ”M” model Cast Ductile Iron Cast Nickel-Aluminum-Bronze Cast Duplex Stainless Steel Cast/Forged/Plate Carbon Steel ”MS” model Forged Nickel-Aluminum-Bronze Forged 15-5 Stainless Steel Cast/Forged/Plate Carbon Steel ”H” model Forged Carbon Steel Forged 15-5 Stainless Steel
Dimensions (Inches) B C D 7 1/4 29 28 5 3/4 30 27 3/16 5 3/4 26 1/2 26 7/8 4 3/8 28 25 3/4
E 41 5/8 40 7/8 40 1/8 39 7/8
F 9 7/8 8 1/8 8 7/8 7 3/4
110Q-3 Quintuplex Plunger Pump Performance Data PUMP
110Q-3L (HP125AL)
110Q-3M (HP125AM)
110Q-3MS (HP125MS)
110Q-H (HP125H)
PUMP
110Q-3L (HP125AL)
110Q-3M (HP125AM)
110Q-3MS (HP125MS)
110Q-H (HP125H)
English Units Plunger Plunger BPD Dia. Area per In. Sq. In. RPM 3.000 7.0686 18.3599 2.875 6.4918 16.8618 2.750 5.9396 15.4274 2.625 5.4119 14.0568 2.500 4.9087 12.7500 2.500 4.9087 12.7500 2.375 4.4301 11.5068 2.250 3.9761 10.3275 2.125 3.5466 9.2118 2.000 3.1416 8.1600 1.875 2.7612 7.1718 1.750 2.4053 6.2475 1.625 2.0739 5.3869 1.500 1.7671 4.5900 1.375 1.4849 3.8569 1.250 1.2272 3.1875 1.125 0.9940 2.5819 1.000 0.7854 2.0400 0.875 0.6013 1.5619 0.750 0.4418 1.1475 Brake Horsepower Required
GPM per RPM 0.5355 0.4918 0.4500 0.4100 0.3719 0.3719 0.3356 0.3012 0.2687 0.2380 0.2092 0.1822 0.1571 0.1339 0.1125 0.0930 0.0753 0.0595 0.0456 0.0335
Metric Units Plunger Plunger Dia. Area mm cm2 76 45.604 73 41.883 70 38.320 67 34.915 64 31.669 64 31.669 60 28.581 57 25.652 54 22.881 51 20.268 48 17.814 44 15.518 41 13.380 38 11.401 35 9.580 32 7.917 29 6.413 25 5.067 22 3.879 19 2.850 Kilowatts Required
L/Sec. per RPM 0.0338 0.0310 0.0284 0.0259 0.0235 0.0235 0.0212 0.0190 0.0170 0.0150 0.0132 0.0115 0.0099 0.0084 0.0071 0.0059 0.0048 0.0038 0.0029 0.0021
M3/Hr per RPM 0.1216 0.1117 0.1022 0.0931 0.0845 0.0845 0.0762 0.0684 0.0610 0.0540 0.0475 0.0414 0.0357 0.0304 0.0255 0.0211 0.0171 0.0135 0.0103 0.0076
100 * RPM Max. Press. PSI 720 784 857 941 1037 1037 1149 1280 1435 1620 1843 2116 2454 2880 3428 4148 5121 6481 8465 10000
BPD 1836 1687 1543 1406 1275 1275 1151 1033 922 816 718 625 539 459 386 319 259 204 157 115
GPM 53.5 49.2 45.0 41.0 37.2 37.2 33.6 30.1 26.9 23.8 20.9 18.2 15.7 13.4 11.2 9.3 7.5 5.9 4.6 3.3 25
200 RPM
BPD 3672 3373 3086 2812 2550 2550 2302 2066 1843 1632 1435 1250 1078 918 772 638 517 408 313 230
250 RPM
GPM 107.1 98.4 90.0 82.0 74.4 74.4 67.1 60.2 53.7 47.6 41.8 36.4 31.4 26.8 22.5 18.6 15.1 11.9 9.1 6.7
BPD 4590 4216 3857 3515 3188 3188 2877 2582 2303 2040 1793 1562 1347 1148 965 797 646 510 391 287
50
GPM 133.9 123.0 112.5 102.5 93.0 93.0 83.9 75.3 67.2 59.5 52.3 45.6 39.3 33.5 28.1 23.2 18.8 14.9 11.4 8.4
300 RPM
BPD 5508 5059 4629 4218 3825 3825 3453 3099 2764 2448 2152 1875 1617 1377 1158 957 775 612 469 345
63
100 * RPM 200 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 4965 12.2 3.4 24.3 6.8 5406 11.2 3.1 22.3 6.2 5909 10.2 2.8 20.4 5.7 6485 9.3 2.6 18.6 5.2 7149 8.4 2.3 16.9 4.7 7149 8.4 2.3 16.9 4.7 7922 7.6 2.1 15.2 4.2 8826 6.8 1.9 13.7 3.8 9895 6.1 1.7 12.2 3.4 11171 5.4 1.5 10.8 3.0 12710 4.8 1.3 9.5 2.6 14591 4.1 1.1 8.3 2.3 16922 3.6 1.0 7.1 2.0 19859 3.0 0.8 6.1 1.7 23634 2.6 0.7 5.1 1.4 28598 2.1 0.6 4.2 1.2 35306 1.7 0.5 3.4 1.0 44684 1.4 0.4 2.7 0.8 58362 1.0 0.3 2.1 0.6 68948 0.8 0.2 1.5 0.4 19 37
250 RPM
M3/Hr 30.4 27.9 25.5 23.3 21.1 21.1 19.1 17.1 15.3 13.5 11.9 10.3 8.9 7.6 6.4 5.3 4.3 3.4 2.6 1.9
L/Sec. 8.4 7.8 7.1 6.5 5.9 5.9 5.3 4.8 4.2 3.8 3.3 2.9 2.5 2.1 1.8 1.5 1.2 0.9 0.7 0.5 47
GPM 160.6 147.5 135.0 123.0 111.6 111.6 100.7 90.4 80.6 71.4 62.8 54.7 47.1 40.2 33.7 27.9 22.6 17.8 13.7 10.0 75
300 RPM
M3/Hr 36.5 33.5 30.7 27.9 25.3 25.3 22.9 20.5 18.3 16.2 14.3 12.4 10.7 9.1 7.7 6.3 5.1 4.1 3.1 2.3
350 RPM
BPD 6426 5902 5400 4920 4463 4463 4028 3615 3225 2856 2511 2187 1886 1607 1350 1116 904 714 547 402
GPM 187.4 172.1 157.5 143.5 130.2 130.2 117.5 105.4 94.0 83.3 73.2 63.8 55.0 46.9 39.4 32.5 26.4 20.8 15.9 11.7
440 RPM
BPD 8079 7420 6789 6186 5610 5610 5064 4545 4054 3591 3156 2749 2371 2020 1698 1403 1137 898 688 505
GPM 235.6 216.4 198.0 180.4 163.6 163.6 147.7 132.5 118.2 104.7 92.0 80.2 69.1 58.9 49.5 40.9 33.1 26.2 20.0 14.7
87
110
350 RPM
440 RPM
L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. 10.1 42.6 11.8 53.5 14.9 9.3 39.1 10.9 49.1 13.7 8.5 35.8 9.9 45.0 12.5 7.8 32.6 9.1 41.0 11.4 7.0 29.6 8.2 37.2 10.3 7.0 29.6 8.2 37.2 10.3 6.4 26.7 7.4 33.5 9.3 5.7 23.9 6.7 30.1 8.4 5.1 21.4 5.9 26.8 7.5 4.5 18.9 5.3 23.8 6.6 4.0 16.6 4.6 20.9 5.8 3.4 14.5 4.0 18.2 5.1 3.0 12.5 3.5 15.7 4.4 2.5 10.6 3.0 13.4 3.7 2.1 8.9 2.5 11.2 3.1 1.8 7.4 2.1 9.3 2.6 1.4 6.0 1.7 7.5 2.1 1.1 4.7 1.3 5.9 1.7 0.9 3.6 1.0 4.6 1.3 0.6 2.7 0.7 3.3 0.9 56 65 82
Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. *Operation below 150 RPM requires an “optional” externally-mounted electric motor-driven auxillary lubrication system. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
125T-4 Triplex Plunger Pump Specifications
43 C PUMP L
F
9 7/8 E 21 1/2 3 3/4
4
3 5/8
3.750 3.749
DIA
7/8 x 7/16 KEYWAY
B
9
2 3/8
3 1/4 1/ 54
AND DISCHARGE
C CRANK L
E 9 7/8
FACE OF SUCTION
21 1/2
26
Pump Size maximum plunger size x stroke length in.(mm): 4 x 4 (101.6 x 101.6) Rated bhp at 450 rpm (kw): 125 (93) Rated plunger load pounds(Kg): 8250 (3742.2) Maximum discharge pressure: psi(kPa) “L” model: 1500 (10,342) “M” model: 3180 (21,925) “H” model: 5000 (34,474) Crankshaft extension: in.(mm) Diameter: 3 3/4 (95.25) Length: 7 1/2 (191) Keyway (width x depth): 7/8 x 7/16 (22.2 x 11.1) Maximum recommended sheave in.(mm): 44 (1118) Minimum recommended sheave in.(mm): 24 (610) For larger sizes: Contact Factory Pinion shaft extension, if gear reducer is supplied in.(mm) For belt or chain drive: Contact Factory For direct drive: Diameter: 2 7/8 (73) Length: 6 3/4 (171) Keyway (width x depth): 3/4 x 3/8 (19 x 9.5) Accessory gear reduction unit: 2.596:1, 3.109:1, 3.947:1, 6.192:1 Oil Capacity, gallons (L) Crankcase & Gear - Approximate: 10 (38) Weight, pump only on wood shipping skids pounds (Kg): 1747 (792) with Gear reducer, approximate pounds (Kg): 2322 (1053)
28
9 1/4
36 3/8 A
Pump Model 125T-4L 125T-4M 125T-4H
Flange Connections Discharge Connection Sizes Suction Connection Sizes 3 (76.2) Sch. 160, V-Bevel 6 (152.4) Sch. 40, V-bevel 3 (76.2) Sch. 160, V-Bevel 4 (101.6) Sch. 40, V-bevel 2 (50.8) Sch. 160, V-Bevel 3 (76.1) Sch. 40, V-bevel
A 53 52 1/8 52 1/8
B 2 4 6 3/8
Dimensions in inches (mm) C D E F G 15 3/4 20 1/2 16 32 6 14 19 7/8 15 30 4 12 3/4 17 7/8 15 30 3
H 3 3 2
J 56 7/8 56 56
125T-4 Triplex Plunger Pump Performance Data PUMP
125T-4L
125T-4M
125T-4H
PUMP
125T-4L
125T-4M
125T-4H
English Units Plunger Plunger BPD Dia. Area per In. Sq. In. RPM 4.000 12.5664 22.3816 3.750 11.0447 19.6714 3.500 9.6211 17.1359 3.000 7.0686 12.5897 2.750 5.9396 10.5788 2.500 4.9087 8.7428 2.375 4.4301 7.8904 3.000 7.0686 12.5897 2.750 5.9396 10.5788 2.500 4.9087 8.7428 2.250 3.9761 7.0817 2.000 3.1416 5.5954 1.875 2.7612 4.9178 1.750 2.4053 4.2840 1.625 2.0739 3.6938 2.250 3.9761 7.0817 2.000 3.1416 5.5954 1.875 2.7612 4.9178 1.750 2.4053 4.2840 1.625 2.0739 3.6938 1.500 1.7671 3.1474 1.375 1.4849 2.6447 Brake Horsepower Required
GPM per RPM 0.6528 0.5737 0.4998 0.3672 0.3085 0.2550 0.2301 0.3672 0.3085 0.2550 0.2065 0.1632 0.1434 0.1249 0.1077 0.2065 0.1632 0.1434 0.1249 0.1077 0.0918 0.0771
Metric Units Plunger Plunger Dia. Area mm cm2 102 81.073 95 71.256 89 62.072 76 45.604 70 38.320 64 31.669 60 28.581 76 45.604 70 38.320 64 31.669 57 25.652 51 20.268 48 17.814 44 15.518 41 13.380 57 25.652 51 20.268 48 17.814 44 15.518 41 13.380 38 11.401 35 9.580 Kilowatts Required
L/Sec. per RPM 0.0412 0.0362 0.0315 0.0232 0.0195 0.0161 0.0145 0.0232 0.0195 0.0161 0.0130 0.0103 0.0090 0.0079 0.0068 0.0130 0.0103 0.0090 0.0079 0.0068 0.0058 0.0049
M3/Hr per RPM 0.1483 0.1303 0.1135 0.0834 0.0701 0.0579 0.0523 0.0834 0.0701 0.0579 0.0469 0.0371 0.0326 0.0284 0.0245 0.0469 0.0371 0.0326 0.0284 0.0245 0.0208 0.0175
150 RPM Max. Press. PSI 657 747 857 1167 1389 1500 1500 1167 1389 1681 2075 2626 2988 3180 3180 2075 2626 2988 3430 3978 4669 5000
BPD 3358 2951 2571 1889 1587 1312 1184 1889 1587 1312 1063 840 738 643 555 1063 840 738 643 555 473 397
GPM 97.9 86.1 75.0 55.1 46.3 38.2 34.5 55.1 46.3 38.2 31.0 24.5 21.5 18.7 16.2 31.0 24.5 21.5 18.7 16.2 13.8 11.6 42
250 RPM
BPD 5596 4918 4284 3148 2645 2186 1973 3148 2645 2186 1771 1399 1230 1071 924 1771 1399 1230 1071 924 787 662
GPM 163.2 143.4 124.9 91.8 77.1 63.7 57.5 91.8 77.1 63.7 51.6 40.8 35.9 31.2 26.9 51.6 40.8 35.9 31.2 26.9 22.9 19.3
300 RPM
BPD 6715 5902 5141 3777 3174 2623 2368 3777 3174 2623 2125 1679 1476 1286 1109 2125 1679 1476 1286 1109 945 794
70
150 RPM 250 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 4527 22.2 6.2 37.1 10.3 5150 19.5 5.4 32.6 9.0 5912 17.0 4.7 28.4 7.9 8047 12.5 3.5 20.8 5.8 9577 10.5 2.9 17.5 4.9 10342 8.7 2.4 14.5 4.0 10342 7.8 2.2 13.1 3.6 8047 12.5 3.5 20.8 5.8 9577 10.5 2.9 17.5 4.9 11588 8.7 2.4 14.5 4.0 14306 7.0 2.0 11.7 3.3 18106 5.6 1.5 9.3 2.6 20601 4.9 1.4 8.1 2.3 21925 4.3 1.2 7.1 2.0 21925 3.7 1.0 6.1 1.7 14306 7.0 2.0 11.7 3.3 18106 5.6 1.5 9.3 2.6 20601 4.9 1.4 8.1 2.3 23649 4.3 1.2 7.1 2.0 27427 3.7 1.0 6.1 1.7 32189 3.1 0.9 5.2 1.4 34474 2.6 0.7 4.4 1.2 31 52
GPM 195.8 172.1 149.9 110.2 92.6 76.5 69.0 110.2 92.6 76.5 62.0 49.0 43.0 37.5 32.3 62.0 49.0 43.0 37.5 32.3 27.5 23.1
350 RPM
BPD 7834 6885 5998 4407 3703 3060 2762 4407 3703 3060 2479 1959 1722 1500 1293 2479 1959 1722 1500 1293 1102 926
GPM 228.5 200.8 174.9 128.5 108.0 89.2 80.5 128.5 108.0 89.2 72.3 57.1 50.2 43.7 37.7 72.3 57.1 50.2 43.7 37.7 32.1 27.0
84
97
300 RPM
350 RPM
M3/Hr 44.5 39.1 34.1 25.0 21.0 17.4 15.7 25.0 21.0 17.4 14.1 11.1 9.8 8.5 7.3 14.1 11.1 9.8 8.5 7.3 6.3 5.3
L/Sec. 12.4 10.9 9.5 6.9 5.8 4.8 4.4 6.9 5.8 4.8 3.9 3.1 2.7 2.4 2.0 3.9 3.1 2.7 2.4 2.0 1.7 1.5 63
M3/Hr 51.9 45.6 39.7 29.2 24.5 20.3 18.3 29.2 24.5 20.3 16.4 13.0 11.4 9.9 8.6 16.4 13.0 11.4 9.9 8.6 7.3 6.1
400 RPM
BPD 8953 7869 6855 5036 4232 3498 3157 5036 4232 3498 2833 2239 1968 1714 1478 2833 2239 1968 1714 1478 1259 1058
GPM 261.1 229.5 199.9 146.9 123.4 102.0 92.1 146.9 123.4 102.0 82.6 65.3 57.4 50.0 43.1 82.6 65.3 57.4 50.0 43.1 36.7 30.9 111
400 RPM
450 RPM
BPD 10072 8853 7712 5666 4761 3935 3551 5666 4761 3935 3187 2518 2214 1928 1663 3187 2518 2214 1928 1663 1417 1191
GPM 293.8 258.2 224.9 165.2 138.8 114.7 103.6 165.2 138.8 114.7 92.9 73.4 64.5 56.2 48.5 92.9 73.4 64.5 56.2 48.5 41.3 34.7 125
450 RPM
L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. 14.4 59.3 16.5 66.7 18.5 12.7 52.1 14.5 58.6 16.3 11.0 45.4 12.6 51.1 14.2 8.1 33.4 9.3 37.5 10.4 6.8 28.0 7.8 31.5 8.8 5.6 23.2 6.4 26.1 7.2 5.1 20.9 5.8 23.5 6.5 8.1 33.4 9.3 37.5 10.4 6.8 28.0 7.8 31.5 8.8 5.6 23.2 6.4 26.1 7.2 4.6 18.8 5.2 21.1 5.9 3.6 14.8 4.1 16.7 4.6 3.2 13.0 3.6 14.7 4.1 2.8 11.4 3.2 12.8 3.5 2.4 9.8 2.7 12.8 3.1 4.6 18.8 5.2 21.1 5.9 3.6 14.8 4.1 16.7 4.6 3.2 13.0 3.6 14.7 4.1 2.8 11.4 3.2 12.8 3.5 2.4 9.8 2.7 11.0 3.1 2.0 8.3 2.3 9.4 2.6 1.7 7.0 1.9 7.9 2.2 73 83 93
Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. Not all plunger sizes are shown. Contact National-Oilwell for additional information. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
130T-4 Triplex Plunger Pump 5/8" x 5/16" KEYWAY 6 1/2
9 3/8
Specifications
2.375 DIA. 2.374
24 7/16
11 7/16
48 7/8
6 1/2
CL PLUNGER #1
11 1/4
C 6 1/2
22 1/2
CL PLUNGER #2
CL PLUNGER #3
8 5/16
7/8" x 7/16" KEYWAY (BOTH ENDS)
7/8" DIA. MOUNTING HOLES - 4 PLACES
SHAFT EXTENSION FOR DIRECT DRIVE 3.750 3.749
SUCTION AND DISCHARGE CONNECTIONS MAY BE MADE EITHER END.
1 1/2" N.P.T. MUD TRAP DRAIN
DIA. (BOTH ENDS)
2
1 1/2" N.P.T. DRAIN BOTH SIDES
10 7/8
B
19 5/8
A
CL DISCHARGE
CL SUCTION
6 2
Pump Size maximum plunger size x stroke length in.(mm): 3 5/8 x 4 (92.1 x 101.6) Rated bhp at 450 rpm (kw): 130 (97) Rated plunger load, pounds(Kg): 8590 (3899) Maximum discharge pressure: psi(kPa) “L” model: 1750 (12,070) “M” model: 3111 (21,458) “H” model: 5000 (34,474) Crankshaft extension: in.(mm) Diameter: 3 3/4 (95.25) Length long side: 8 1/2 (215.9) Length short side: 8 5/16 (211.4) Keyway (width x depth): 7/8 x 7/16 (22.2 x 11.1) Maximum recommended sheave in.(mm): 44 (1118) Minimum recommended sheave in.(mm): 24 (610) For larger sizes: Contact Factory Pinion shaft extension, if gear reducer is supplied in.(mm) For belt or chain drive: Contact Factory For direct drive: Diameter: 2 3/8 (60.33) Length: 6 1/2 (165.10) Keyway (width x depth): 5/8 x 5/16 (15.9 x 7.9) Accessory gear reduction unit: 2.60:1, 3.15:1, 3.42:1, 3.89:1, 4.27:1 Oil Capacity, gallons (L) Crankcase: 5.5 (20.8) Gear Reducer: 3 (11.40) Weight, pump only on wood shipping skids pounds (Kg): 2360 (1070.5) Gear reducer, approximate pounds (Kg): 500 (226.8)
2" N.P.T. DRAIN
27 1/8
8 3/4
D E
Pump Model 130T-4L 130T-4M 130T-4H
Flange Connections Discharge Connection Sizes Suction Connection Sizes 2 1/2 (63.5) API-2000 RJ 5 (127) ANSI-150 FF 1 1/2 (38.1) API-5000 RJ 3 (76.2) ANSI-150 FF 1 1/2 (38.1) ANSI-2500 RJ 3 (76.2) ANSI-300 FF
A 5 5/8 4 3/4 4 3/4
Dimensions in inches (mm) B C D E 6 7/8 25 1/2 42 5/8 58 3/8 5 1/4 23 3/4 41 7/8 55 3/8 5 1/4 25 1/2 41 1/2 56 3/8
130T-4 Triplex Plunger Pump Performance Data PUMP
130T-4L
130T-4M
130T-4H
PUMP
130T-4L
130T-4M
130T-4H
English Units Plunger Plunger BPD Dia. Area per In. Sq. In. RPM 3.625 10.3206 18.3818 3.500 9.6211 17.1359 3.250 8.2958 14.7754 3.000 7.0686 12.5897 2.750 5.9396 10.5788 2.625 5.4119 9.6390 2.500 4.9087 8.7428 2.375 4.4301 7.8904 2.250 3.9761 7.0817 2.125 3.5466 6.3167 2.000 3.1416 5.5954 1.875 2.7612 4.9178 1.750 2.4053 4.2840 1.625 2.0739 3.6938 1.500 1.7671 3.1474 1.375 1.4849 2.6447 Brake Horsepower Required
GPM per RPM 0.5361 0.4998 0.4309 0.3672 0.3085 0.2811 0.2550 0.2301 0.2065 0.1842 0.1632 0.1434 0.1249 0.1077 0.0918 0.0771
Metric Units Plunger Plunger Dia. Area mm cm2 92 66.584 89 62.072 83 53.521 76 45.604 70 38.320 67 34.915 64 31.669 60 28.581 57 25.652 54 22.881 51 20.268 48 17.814 44 15.518 41 13.380 38 11.401 35 9.580 Kilowatts Required
L/Sec. per RPM 0.0338 0.0315 0.0272 0.0232 0.0195 0.0177 0.0161 0.0145 0.0130 0.0116 0.0103 0.0090 0.0079 0.0068 0.0058 0.0049
M3/Hr per RPM 0.1218 0.1135 0.0979 0.0834 0.0701 0.0638 0.0579 0.0523 0.0469 0.0418 0.0371 0.0326 0.0284 0.0245 0.0208 0.0175
150 RPM Max. Press. PSI 832 893 1035 1215 1446 1587 1750 1939 2160 2422 2734 3111 3571 4142 4861 5000
BPD 2758 2571 2217 1889 1587 1446 1312 1184 1063 948 840 738 643 555 473 397
GPM 80.4 75.0 64.6 55.1 46.3 42.2 38.2 34.5 31.0 27.6 24.5 21.5 18.7 16.2 13.8 11.6 44
250 RPM
BPD 4596 4284 3694 3148 2645 2410 2186 1973 1771 1580 1399 1230 1071 924 787 662
300 RPM
GPM 134.0 124.9 107.7 91.8 77.1 70.3 63.7 57.5 51.6 46.1 40.8 35.9 31.2 26.9 22.9 19.3
BPD 5515 5141 4433 3777 3174 2892 2623 2368 2125 1896 1679 1476 1286 1109 945 794
73
GPM 160.8 149.9 129.3 110.2 92.6 84.3 76.5 69.0 62.0 55.3 49.0 43.0 37.5 32.3 27.5 23.1
350 RPM
BPD 6434 5998 5172 4407 3703 3374 3060 2762 2479 2211 1959 1722 1500 1293 1102 926
87
150 RPM 250 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 5739 18.3 5.1 30.4 8.5 6156 17.0 4.7 28.4 7.9 7139 14.7 4.1 24.5 6.8 8379 12.5 3.5 20.8 5.8 9971 10.5 2.9 17.5 4.9 10944 9.6 2.7 16.0 4.4 12065 8.7 2.4 14.5 4.0 13369 7.8 2.2 13.1 3.6 14896 7.0 2.0 11.7 3.3 16700 6.3 1.7 10.5 2.9 18852 5.6 1.5 9.3 2.6 21450 4.9 1.4 8.1 2.3 24623 4.3 1.2 7.1 2.0 28557 3.7 1.0 6.1 1.7 33515 3.1 0.9 5.2 1.4 34474 2.6 0.7 4.4 1.2 33 54
300 RPM
M3/Hr 36.5 34.1 29.4 25.0 21.0 19.2 17.4 15.7 14.1 12.6 11.1 9.8 8.5 7.3 6.3 5.3
L/Sec. 10.1 9.5 8.2 6.9 5.8 5.3 4.8 4.4 3.9 3.5 3.1 2.7 2.4 2.0 1.7 1.5 65
GPM 187.6 174.9 150.8 128.5 108.0 98.4 89.2 80.5 72.3 64.5 57.1 50.2 43.7 37.7 32.1 27.0 101
350 RPM
M3/Hr 42.6 39.7 34.3 29.2 24.5 22.3 20.3 18.3 16.4 14.6 13.0 11.4 9.9 8.6 7.3 6.1
400 RPM
BPD 7353 6855 5911 5036 4232 3856 3498 3157 2833 2527 2239 1968 1714 1478 1259 1058
GPM 214.5 199.9 172.4 146.9 123.4 112.5 102.0 92.1 82.6 73.7 65.3 57.4 50.0 43.1 36.7 30.9 116
400 RPM
450 RPM
BPD 8272 7712 6649 5666 4761 4338 3935 3551 3187 2843 2518 2214 1928 1663 1417 1191
GPM 241.3 224.9 193.9 165.2 138.8 126.5 114.7 103.6 92.9 82.9 73.4 64.5 56.2 48.5 41.3 34.7 130
450 RPM
L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. 11.8 48.7 13.5 54.8 15.2 11.0 45.4 12.6 51.1 14.2 9.5 39.1 10.9 44.0 12.2 8.1 33.4 9.3 37.5 10.4 6.8 28.0 7.8 31.5 8.8 6.2 25.5 7.1 28.7 8.0 5.6 23.2 6.4 26.1 7.2 5.1 20.9 5.8 23.5 6.5 4.6 18.8 5.2 21.1 5.9 4.1 16.7 4.6 18.8 5.2 3.6 14.8 4.1 16.7 4.6 3.2 13.0 3.6 14.7 4.1 2.8 11.4 3.2 12.8 3.5 2.4 9.8 2.7 11.0 3.1 2.0 8.3 2.3 9.4 2.6 1.7 7.0 1.9 7.9 2.2 75 86 97
Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. Not all plunger sizes are shown. Contact National-Oilwell for additional information. For operations below 200 RPM, auxiliary lubrication system required. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
133T-4 Triplex Plunger Pump Specifications
INTERNAL LUBE PUMP
ÿ .75 TYP 4 PLACES PRESSURE GAUGE
19.37
8.00 18.25 16.00
C
C/2 13.23
ROTATION DIRECTION 9.84
ÿ
3.750 3.749
.875 x .500 KEYWAY 7.750 LONG DISCHARGE CONNECTION
F A 20.31
B 10.00
1.00 SUCTION CONNECTION
5.25
8.81
24.25
D
E
Pump Model 133T-4L 133T-4M 133T-4H
Flange Connections Discharge Connection Sizes Suction Connection Sizes 3 (76.2)-600# ANSI FF 6 (152.4)-150# ANSI FF 2 (50.8)-1500# ANSI FF 4 (101.6)-300# ANSI FF 2 (50.8)-2500# ANSI RJ 3 (76.2)-2500# ANSI RJ
A 4 5/8 5 1/16 5 1/8
Pump Size: maximum plunger size x stroke length, in.(mm): 3.375 x 4.500 (85.7 x 114.3) Rated BHP (kW) at 400 RPM: 133 (99) Rated plunger load, pounds (kg): 8800 (3992) Maximum discharge pressure: psi (kPa) “L” model: 1440 (9929) “M” model: 3600 (24821) “H” model: 6000 (41369) Crankshaft extension: Diameter, in.(mm): 3.750 (95.25) Length, in.(mm): 9.84 (249.9) Keyway width x depth, in.(mm): 7/8 x 1/2 (22.225 x 12.7) Maximum recommended sheave diameter, in. (mm): 53 (1346.2) For larger sizes: Contact Factory Pinion shaft extension, if gear reducer is supplied, in. (mm) For belt or chain drive: N/A For direct drive: Diameter: 2.000 (50.8) Length: 4.25 (108.0) Keyway width x depth: 1/2 x 1/4 (12.70 x 6.35) Accessory gear reduction unit: 3.00:1, 3.12:1, 3.23:1, 3.36:1, 3.49:1, 3.62:1, 3.78:1, 3.94:1, 4.11:1, 4.29:1, 4.48:1, 4.69:1, 4.93:1, 5.17:1 Oil Capacity, gallons (L) Crankcase: 6 (22.71) Gear Reducer - varies with ratio: 1.25 to 1.50 (4.73 to 5.68) Weight, pump only on wood shipping skids, pounds (kg) “L” model: 1650 (748) “M” model: 1650 (748) “H” model: 1650 (748) Standard Materials For Fluid End Bodies “L” model Cast Nickel-Aluminum-Bronze Cast Duplex Stainless Steel Forged/Plate Carbon Steel “M” model Cast Nickel-Aluminum-Bronze Cast Duplex Stainless Steel Forged/Plate Carbon Steel “H” model Forged Carbon Steel Duplex Stainless Steel
Dimensions (Inches) B C D E 7 7/8 2 33 3/4 48 5/8 6 3/16 2 33 3/8 47 3/4 6 1/8 30 1/8 36 3/4 52 1/2
F 9 5/8 9 12 1/8
133T-4 Triplex Plunger Pump Performance Data PUMP
133T-4L (T140-4)
133T-4M (T140-3)
133T-4H (T140-2)
PUMP
133T-4L (T140-4)
133T-4M (T140-3)
133T-4H (T140-2)
English Units Plunger Plunger BPD Dia. Area per In. Sq. In. RPM 3.375 8.9462 17.9255 3.250 8.2958 16.6223 3.125 7.6699 15.3682 3.000 7.0686 14.1634 2.875 6.4918 13.0077 2.750 5.9396 11.9012 2.625 5.4119 10.8438 2.500 4.9087 9.8357 2.375 4.4301 8.8767 2.250 3.9761 7.9669 2.125 3.5466 7.1063 2.000 3.1416 6.2948 1.875 2.7612 5.5326 1.750 2.4053 4.8195 1.625 2.0739 4.1556 1.500 1.7671 3.5408 1.375 1.4849 2.9753 1.250 1.2272 2.4589 Brake Horsepower Required
GPM per RPM 0.5228 0.4848 0.4482 0.4131 0.3794 0.3471 0.3163 0.2869 0.2589 0.2324 0.2073 0.1836 0.1614 0.1406 0.1212 0.1033 0.0868 0.0717
Metric Units Plunger Plunger Dia. Area mm cm2 86 57.717 83 53.521 79 49.483 76 45.604 73 41.883 70 38.320 67 34.915 64 31.669 60 28.581 57 25.652 54 22.881 51 20.268 48 17.814 44 15.518 41 13.380 38 11.401 35 9.580 32 7.917 Kilowatts Required
L/Sec. per RPM 0.0330 0.0306 0.0283 0.0261 0.0239 0.0219 0.0200 0.0181 0.0163 0.0147 0.0131 0.0116 0.0102 0.0089 0.0076 0.0065 0.0055 0.0045
M3/Hr per RPM 0.1187 0.1101 0.1018 0.0938 0.0862 0.0788 0.0718 0.0651 0.0588 0.0528 0.0471 0.0417 0.0366 0.0319 0.0275 0.0235 0.0197 0.0163
100 RPM Max. Press. PSI 984 1061 1147 1245 1356 1440 1440 1793 1986 2213 2481 2801 3187 3600 4243 4980 5926 6000
BPD 1793 1663 1537 1417 1301 1191 1085 984 888 797 711 630 554 482 416 355 298 246
GPM 52.3 48.5 44.8 41.3 37.9 34.7 31.6 28.7 25.9 23.2 20.7 18.4 16.1 14.1 12.1 10.3 8.7 7.2 34
150 RPM
BPD 2689 2494 2306 2125 1952 1786 1627 1476 1332 1196 1066 945 830 723 624 532 447 369
250 RPM
GPM 78.4 72.7 67.2 62.0 56.9 52.1 47.4 43.0 38.8 34.9 31.1 27.5 24.2 21.1 18.2 15.5 13.0 10.8
BPD 4482 4156 3843 3541 3252 2976 2711 2459 2220 1992 1777 1574 1384 1205 1039 886 744 615
51
300 RPM
GPM 130.7 121.2 112.1 103.3 94.8 86.8 79.1 71.7 64.7 58.1 51.8 45.9 40.3 35.1 30.3 25.8 21.7 17.9
BPD 5378 4987 4611 4250 3903 3571 3254 2951 2664 2391 2132 1889 1660 1446 1247 1063 893 738
84
100 RPM 150 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 6782 11.9 3.3 17.8 4.9 7314 11.0 3.1 16.5 4.6 7911 10.2 2.8 15.3 4.2 8584 9.4 2.6 14.1 3.9 9346 8.6 2.4 12.9 3.6 9929 7.9 2.2 11.8 3.3 9929 7.2 2.0 10.8 3.0 12360 6.5 1.8 9.8 2.7 13696 5.9 1.6 8.8 2.5 15260 5.3 1.5 7.9 2.2 17108 4.7 1.3 7.1 2.0 19313 4.2 1.2 6.3 1.7 21974 3.7 1.0 5.5 1.5 24821 3.2 0.9 4.8 1.3 29256 2.8 0.8 4.1 1.1 34335 2.3 0.7 3.5 1.0 40861 2.0 0.5 3.0 0.8 41369 1.6 0.5 2.4 0.7 25 38
250 RPM
M3/Hr 29.7 27.5 25.4 23.5 21.5 19.7 18.0 16.3 14.7 13.2 11.8 10.4 9.2 8.0 6.9 5.9 4.9 4.1
L/Sec. 8.2 7.6 7.1 6.5 6.0 5.5 5.0 4.5 4.1 3.7 3.3 2.9 2.5 2.2 1.9 1.6 1.4 1.1 63
GPM 156.8 145.4 134.5 123.9 113.8 104.1 94.9 86.1 77.7 69.7 62.2 55.1 48.4 42.2 36.4 31.0 26.0 21.5 100
300 RPM
M3/Hr 35.6 33.0 30.5 28.1 25.8 23.6 21.5 19.5 17.6 15.8 14.1 12.5 11.0 9.6 8.3 7.0 5.9 4.9
350 RPM
BPD 6274 5818 5379 4958 4553 4166 3796 3443 3107 2789 2488 2204 1937 1687 1455 1240 1042 861
GPM 183.0 169.7 156.9 144.6 132.8 121.5 110.7 100.4 90.6 81.3 72.5 64.3 56.5 49.2 42.4 36.1 30.4 25.1 117
350 RPM
400 RPM
BPD 7171 6649 6148 5666 5204 4761 4338 3935 3551 3187 2843 2518 2214 1928 1663 1417 1191 984
GPM 209.1 193.9 179.3 165.2 151.8 138.8 126.5 114.7 103.6 92.9 82.9 73.4 64.5 56.2 48.5 41.3 34.7 28.7 133
400 RPM
L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. 9.9 41.6 11.5 47.5 13.2 9.2 38.5 10.7 44.0 12.2 8.5 35.6 9.9 40.7 11.3 7.8 32.8 9.1 37.5 10.4 7.2 30.2 8.4 34.5 9.6 6.6 27.6 7.7 31.5 8.8 6.0 25.1 7.0 28.7 8.0 5.4 22.8 6.3 26.1 7.2 4.9 20.6 5.7 23.5 6.5 4.4 18.5 5.1 21.1 5.9 3.9 16.5 4.6 18.8 5.2 3.5 14.6 4.1 16.7 4.6 3.1 12.8 3.6 14.7 4.1 2.7 11.2 3.1 12.8 3.5 2.3 9.6 2.7 11.0 3.1 2.0 8.2 2.3 9.4 2.6 1.6 6.9 1.9 7.9 2.2 1.4 5.7 1.6 6.5 1.8 75 87 99
Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
163Q-4 Quintuplex Plunger Pump Specifications
20.79 14.00 TYP
C 28.00 TYP
C/2 19.22
ÿ.75 TYP 4 PLACES
6.27
.750 x .375 KEYWAY 5.125 LONG
ÿ
3.000 2.999
ROTATION DIRECTION
DISCHARGE CONNECTION
F A
1.00 20.42
B 10.00 .75
SUCTION CONNECTION 5.25
24.25
9.89
D
E
Pump Model 163Q-4L 163Q-4M 163Q-4H
Flange Connections Discharge Connection Sizes Suction Connection Sizes 3 (76.2)-600# ANSI FF 6 (152.4)-150# ANSI FF 2 (50.8)-1500# ANSI FF 4 (101.6)-300# ANSI FF 2 (50.8)-11 1/2 NPT 3 (76.2)-8 NPT
A 4 5/8 5 1/16 5 1/16
Pump Size: maximum plunger size x stroke length, in.(mm): 3.375 x 4.500 (85.725 x 114.3) Rated BHP (kW) at 390 RPM: 163 (121) Rated plunger load, pounds (kg): 6600 (2994) Maximum discharge pressure: psi (kPa) “L” model: 1220 (8408) “M” model: 2744 (18919) “H” model: 5378 (37081) Crankshaft extension: Diameter, in.(mm): 3.000 (76.2) Length, in.(mm): 6.27 (159.3) Keyway width x depth, in.(mm): 3/4 x 3/8 (19.05 x 9.525) Maximum recommended sheave diameter, in.(mm): 53 (1346.2) For larger sizes: Contact Customer Service Pinion shaft extension, if gear reducer is supplied, in.(mm) For belt or chain drive: N/A For direct drive: Diameter: 2.500 (63.5) Length: 5.000 (127.0) Keyway width x depth: 5/8 x 5/16 (15.88 x7.94) Accessory gear reduction unit: 2.06:1, 2.26:1, 3.60:1, 4.25:1, 4.65:1, 4.88:1, 5.13:1, 5.40:1, 5.69:1 Oil Capacity, gallons (L) Crankcase: 7 (26.5) Gear Reducer-varies with ratio: 2.00 to 2.25 (7.57 to 8.52) Weight, pump only on wood shipping skids, pounds (kg): 2913 (1322) Weight varies with pump model Standard Materials for Fluid Ends: “L” model Cast Nickel-Aluminum-Bronze Cast Duplex Stainless Steel Plate Carbon Steel Cast Ductile Iron “M” model Cast Nickel-Aluminum-Bronze Cast Duplex Stainless Steel Plate Carbon Steel Forged Nickel-Aluminum-Bronze “H” model Forged 15-5 Stainless Steel Forged/Plate Carbon Steel
Dimensions (Inches) B C D E 7 7/8 33 33 3/8 49 7/16 5 7/8 33 33 38 3/4 6 3/16 31 1/2 33 39 3/4
F 9 5/8 9 1/2 10 3/4
G 3 3/8 7/8 -1 5/8
163Q-4 Quintuplex Plunger Pump Performance Data PUMP
163Q-4L (HP165AL)
163Q-4M (HP165AM)
163Q-4H (HP165MS)
PUMP
163Q-4L (HP165AL)
163Q-4M (HP165AM)
163Q-4H (HP165MS)
English Units Plunger Plunger BPD Dia. Area per In. Sq. In. RPM 3.375 8.9462 29.8759 3.250 8.2958 27.7038 3.125 7.6699 25.6137 3.000 7.0686 23.6056 2.875 6.4918 21.6795 2.750 5.9396 19.8353 2.625 5.4119 18.0731 2.500 4.9087 16.3928 2.375 4.4301 14.7945 2.250 3.9761 13.2782 2.125 3.5466 11.8438 2.000 3.1416 10.4914 1.875 2.7612 9.2209 1.750 2.4053 8.0325 1.625 2.0739 6.9260 1.500 1.7671 5.9014 1.375 1.4849 4.9588 1.250 1.2272 4.0982 Brake Horsepower Required
GPM per RPM 0.8714 0.8080 0.7471 0.6885 0.6323 0.5785 0.5271 0.4781 0.4315 0.3873 0.3454 0.3060 0.2689 0.2343 0.2020 0.1721 0.1446 0.1195
Metric Units Plunger Plunger Dia. Area mm cm2 86 57.717 83 53.521 79 49.483 76 45.604 73 41.883 70 38.320 67 34.915 64 31.669 60 28.581 57 25.652 54 22.881 51 20.268 48 17.814 44 15.518 41 13.380 38 11.401 35 9.580 32 7.917 Kilowatts Required
L/Sec. per RPM 0.0550 0.0510 0.0471 0.0434 0.0399 0.0365 0.0333 0.0302 0.0272 0.0244 0.0218 0.0193 0.0170 0.0148 0.0127 0.0109 0.0091 0.0075
M3/Hr per RPM 0.1979 0.1835 0.1697 0.1564 0.1436 0.1314 0.1197 0.1086 0.0980 0.0880 0.0785 0.0695 0.0611 0.0532 0.0459 0.0391 0.0328 0.0271
50 RPM Max. Press. PSI 738 796 861 934 1017 1111 1220 1345 1490 1660 1861 2101 2390 2744 3182 3735 4445 5378
BPD 1494 1386 1281 1181 1084 992 904 820 740 664 593 525 462 402 347 296 248 205
GPM 43.6 40.4 37.4 34.4 31.6 28.9 26.4 23.9 21.6 19.4 17.3 15.3 13.4 11.7 10.1 8.6 7.2 6.0 21
150 RPM
BPD 4482 4156 3843 3541 3252 2976 2711 2459 2220 1992 1777 1574 1384 1205 1039 886 744 615
200 RPM
GPM 130.7 121.2 112.1 103.3 94.8 86.8 79.1 71.7 64.7 58.1 51.8 45.9 40.3 35.1 30.3 25.8 21.7 17.9
BPD 5976 5541 5123 4722 4336 3968 3615 3279 2959 2656 2369 2099 1845 1607 1386 1181 992 820
63
GPM 174.3 161.6 149.4 137.7 126.5 115.7 105.4 95.6 86.3 77.5 69.1 61.2 53.8 46.9 40.4 34.4 28.9 23.9
250 RPM
BPD 7469 6926 6404 5902 5420 4959 4519 4099 3699 3320 2961 2623 2306 2009 1732 1476 1240 1025
84
50 RPM 150 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 5087 9.9 2.7 29.7 8.2 5485 9.2 2.5 27.5 7.6 5933 8.5 2.4 25.4 7.1 6438 7.8 2.2 23.5 6.5 7010 7.2 2.0 21.5 6.0 7661 6.6 1.8 19.7 5.5 8408 6.0 1.7 18.0 5.0 9270 5.4 1.5 16.3 4.5 10272 4.9 1.4 14.7 4.1 11445 4.4 1.2 13.2 3.7 12831 3.9 1.1 11.8 3.3 14485 3.5 1.0 10.4 2.9 16481 3.1 0.8 9.2 2.5 18919 2.7 0.7 8.0 2.2 21942 2.3 0.6 6.9 1.9 25751 2.0 0.5 5.9 1.6 30646 1.6 0.5 4.9 1.4 37081 1.4 0.4 4.1 1.1 16 47
200 RPM
M3/Hr 39.6 36.7 33.9 31.3 28.7 26.3 23.9 21.7 19.6 17.6 15.7 13.9 12.2 10.6 9.2 7.8 6.6 5.4
L/Sec. 11.0 10.2 9.4 8.7 8.0 7.3 6.7 6.0 5.4 4.9 4.4 3.9 3.4 3.0 2.5 2.2 1.8 1.5 63
GPM 217.8 202.0 186.8 172.1 158.1 144.6 131.8 119.5 107.9 96.8 86.4 76.5 67.2 58.6 50.5 43.0 36.2 29.9 104
250 RPM
M3/Hr 49.5 45.9 42.4 39.1 35.9 32.8 29.9 27.1 24.5 22.0 19.6 17.4 15.3 13.3 11.5 9.8 8.2 6.8
300 RPM
BPD 8963 8312 7685 7082 6504 5951 5422 4918 4439 3984 3554 3148 2767 2410 2078 1771 1488 1230
GPM 261.4 242.4 224.1 206.5 189.7 173.6 158.1 143.4 129.5 116.2 103.6 91.8 80.7 70.3 60.6 51.6 43.4 35.9 125
300 RPM
390 RPM
BPD 11652 10805 9990 9207 8455 7736 7049 6394 5770 5179 4620 4092 3597 3133 2702 2302 1934 1599
GPM 339.8 315.1 291.4 268.5 246.6 225.6 205.6 186.5 168.3 151.0 134.7 119.3 104.9 91.4 78.8 67.1 56.4 46.6 163
390 RPM
L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. 13.7 59.4 16.5 77.2 21.4 12.7 55.1 15.3 71.6 19.9 11.8 50.9 14.1 66.2 18.4 10.9 46.9 13.0 61.0 16.9 10.0 43.1 12.0 56.0 15.6 9.1 39.4 10.9 51.2 14.2 8.3 35.9 10.0 46.7 13.0 7.5 32.6 9.0 42.3 11.8 6.8 29.4 8.2 38.2 10.6 6.1 26.4 7.3 34.3 9.5 5.4 23.5 6.5 30.6 8.5 4.8 20.8 5.8 27.1 7.5 4.2 18.3 5.1 23.8 6.6 3.7 16.0 4.4 20.7 5.8 3.2 13.8 3.8 17.9 5.0 2.7 11.7 3.3 15.2 4.2 2.3 9.9 2.7 12.8 3.6 1.9 8.1 2.3 10.6 2.9 78 93 121
Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. *Operation below 150 RPM requires an “optional” externallymounted electric motor-driven auxillary lubrication system. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
165T-5 Triplex Plunger Pump 15 5/8 4.125 4.123
3.000 2.999
DIA
Specifications
DIA
8 1/8
9 7/16
6 3/16
3/4" x 3/8" KEYWAY
SUCTION AND DISCHARGE CONNECTIONS MAY BE MADE AT EITHER END
13 1/8
7 1/2
"C"
51 7/8
7 1/2
26 1/4
26 15/16
1" x 1/2" KEYWAY
5 7/8
1 1/8" DIA HOLES 4 PLACES AS SHOWN 1" x 1/2" KEYWAY 4.125 4.123
SHAFT EXTENSION FOR DIRECT DRIVE
DIA
14 1/2
"D" 36 1/2
+ "B"
6
10
12 1/4
7
2 1/4 CENTERLINE SUCTION
2 1/4
"F"
29
CENTERLINE DISCHARGE
"A"
1 1/2 " STD PIPE TAP CRADLE DRAIN, BOTH SIDES
Pump Size (maximum plunger size x stroke length in.(mm) 4 x 5 (102 x 127) Rated bhp at 400 rpm (kw) 165 (123) Rated plunger load, pounds (Kg) 9800 (4445.2) Maximum discharge pressure: psi (kPa) “L” model: 1650 (11,376) “M” model: 3120 (21,512) “H” model: 5000 (34,474) Crankshaft extension: in.(mm) Diameter: 4.125 (104.8) Length long side: 8 1/8 (206.4) Length short side: 5 7/8 (149.2) Keyway (width x depth): 1 x 1/2 (25.4 x 12.7) Maximum recommended sheave in.(mm): 50 (1270) Minimum recommended sheave in.(mm): 36 (914) For larger sizes: Contact Factory Pinion shaft extension, in.(mm): if gear reducer is supplied For belt or chain drive: Contact Factory For direct drive: Diameter: 3.0 (76.2) Length: 6 3/16 (157.2) Keyway (width x depth): 3/4 x 3/8 (19.05 x 9.53) Accessory gear reduction unit: 2.8:1, 3.22:1, 3.46:1, 4.00:1, 4.38:1, 4.78:1, 4.96:1, 5.74:1 Oil Capacity, gallons (L) Crankcase: 8 (30) Gear Reducer-varies with ratio: 2.25 to 3.5 (8.52 to 13.25) Weight, pump only on wood shipping skids pounds (Kg): 4000 (1814) Gear reducer, approximate pounds (Kg): 800 (363)
1 1/2 " STD PIPE TAP MUD TRAP DRAIN 3 3/4
7 3/4
2" STD PIPE TAP CRADLE DRAIN
19 3/4 40 3/4 "E"
1" STD PIPE TAP POWER END OIL DRAIN
Pump Model 165-5L 165-5M 165-5H
Flange Connections Discharge Connection Sizes Suction Connection Sizes 3 (76.2) API-2000 RJ 6 (152.4) ANSI-150 FF 2 (50.8) API-5000 RJ 4 (101.6) ANSI-150 FF 2 (50.8) ANSI-2500 RJ 3 (76.2) API-2000 RJ
A 5 11/16 4 3/4 4 3/4
Dimensions (Inches) B C D E 7 5/8 27 3/4 48 3/4 65 3/4 6 1/2 26 1/2 48 3/8 64 7/8 6 1/2 26 1/2 48 3/8 64 1/4
F 23 25 5/16 25 5/16
165T-5 Triplex Plunger Pump Performance Data PUMP
165T-5L
165T-5M
165T-5H
PUMP
165T-5L
165T-5M
165T-5H
English Units Plunger Plunger BPD Dia. Area per In. Sq. In. RPM 4.000 12.5664 27.9770 3.750 11.0447 24.5892 3.500 9.6211 21.4199 3.250 8.2958 18.4692 3.000 7.0686 15.7371 2.750 5.9396 13.2235 2.750 5.9396 13.2235 2.500 4.9087 10.9285 2.375 4.4301 9.8630 2.250 3.9761 8.8521 2.125 3.5466 7.8959 2.000 3.1416 6.9943 2.000 3.1416 6.9943 1.875 2.7612 6.1473 1.750 2.4053 5.3550 1.625 2.0739 4.6173 1.500 1.7671 3.9343 Brake Horsepower Required
GPM per RPM 0.8160 0.7172 0.6247 0.5387 0.4590 0.3857 0.3857 0.3187 0.2877 0.2582 0.2303 0.2040 0.2040 0.1793 0.1562 0.1347 0.1147
Metric Units Plunger Plunger Dia. Area mm cm2 102 81.073 95 71.256 89 62.072 83 53.521 76 45.604 70 38.320 70 38.320 64 31.669 60 28.581 57 25.652 54 22.881 51 20.268 51 20.268 48 17.814 44 15.518 41 13.380 38 11.401 Kilowatts Required
L/Sec. per RPM 0.0515 0.0452 0.0394 0.0340 0.0290 0.0243 0.0243 0.0201 0.0181 0.0163 0.0145 0.0129 0.0129 0.0113 0.0099 0.0085 0.0072
M3/Hr per RPM 0.1853 0.1629 0.1419 0.1223 0.1042 0.0876 0.0876 0.0724 0.0653 0.0586 0.0523 0.0463 0.0463 0.0407 0.0355 0.0306 0.0261
100 RPM Max. Press. PSI 780 887 1019 1181 1386 1650 1650 1996 2212 2465 2763 3120 3120 3549 4074 4725 5000
BPD 2798 2459 2142 1847 1574 1323 1323 1093 987 886 790 700 700 615 536 462 394
GPM 81.6 71.7 62.5 53.9 45.9 38.6 38.6 31.9 28.8 25.8 23.0 20.4 20.4 17.9 15.6 13.5 11.5 42
200 RPM
BPD 5596 4918 4284 3694 3148 2645 2645 2186 1973 1771 1580 1399 1399 1230 1071 924 787
250 RPM
GPM 163.2 143.4 124.9 107.7 91.8 77.1 77.1 63.7 57.5 51.6 46.1 40.8 40.8 35.9 31.2 26.9 22.9
BPD 6995 6148 5355 4618 3935 3306 3306 2733 2466 2214 1974 1749 1749 1537 1339 1155 984
83
GPM 204.0 179.3 156.2 134.7 114.7 96.4 96.4 79.7 71.9 64.5 57.6 51.0 51.0 44.8 39.0 33.7 28.7
300 RPM
BPD 8394 7377 6426 5541 4722 3968 3968 3279 2959 2656 2369 2099 2099 1845 1607 1386 1181
104
100 RPM 200 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 5377 18.5 5.1 37.1 10.3 6118 16.3 4.5 32.6 9.0 7023 14.2 3.9 28.4 7.9 8145 12.2 3.4 24.5 6.8 9559 10.4 2.9 20.8 5.8 11376 8.8 2.4 17.5 4.9 11376 8.8 2.4 17.5 4.9 13765 7.2 2.0 14.5 4.0 15252 6.5 1.8 13.1 3.6 16994 5.9 1.6 11.7 3.3 19052 5.2 1.5 10.5 2.9 21512 4.6 1.3 9.3 2.6 21512 4.6 1.3 9.3 2.6 24471 4.1 1.1 8.1 2.3 28092 3.5 1.0 7.1 2.0 32580 3.1 0.8 6.1 1.7 34474 2.6 0.7 5.2 1.4 31 62
250 RPM
M3/Hr 46.3 40.7 35.5 30.6 26.1 21.9 21.9 18.1 16.3 14.7 13.1 11.6 11.6 10.2 8.9 7.6 6.5
L/Sec. 12.9 11.3 9.9 8.5 7.2 6.1 6.1 5.0 4.5 4.1 3.6 3.2 3.2 2.8 2.5 2.1 1.8 78
GPM 244.8 215.2 187.4 161.6 137.7 115.7 115.7 95.6 86.3 77.5 69.1 61.2 61.2 53.8 46.9 40.4 34.4 124
300 RPM
M3/Hr 55.6 48.9 42.6 36.7 31.3 26.3 26.3 21.7 19.6 17.6 15.7 13.9 13.9 12.2 10.6 9.2 7.8
350 RPM
BPD 9792 8607 7497 6465 5508 4629 4629 3825 3453 3099 2764 2448 2448 2152 1875 1617 1377
GPM 285.6 251.0 218.7 188.5 160.6 135.0 135.0 111.6 100.7 90.4 80.6 71.4 71.4 62.8 54.7 47.1 40.2
400 RPM
144
BPD GPM 11191* 326* 9836 286.9 8568 249.9 7388 215.5 6295 183.6 5290 154.3 5290 154.3 4372 127.5 3946 115.1 3541 103.3 3159 92.1 2798 81.6 2798 81.6 2459 71.7 2142 62.5 1847 53.9 1574 45.9 165
350 RPM
400 RPM
L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. 15.4 64.9 18.0 74.1* 20.6* 13.6 57.0 15.8 65.1 18.1 11.8 49.7 13.8 56.8 15.8 10.2 42.8 11.9 48.9 13.6 8.7 36.5 10.1 41.7 11.6 7.3 30.7 8.5 35.0 9.7 7.3 30.7 8.5 35.0 9.7 6.0 25.3 7.0 29.0 8.0 5.4 22.9 6.4 26.1 7.3 4.9 20.5 5.7 23.5 6.5 4.4 18.3 5.1 20.9 5.8 3.9 16.2 4.5 18.5 5.1 3.9 16.2 4.5 18.5 5.1 3.4 14.3 4.0 16.3 4.5 3.0 12.4 3.4 14.2 3.9 2.5 10.7 3.0 12.2 3.4 2.2 9.1 2.5 10.4 2.9 92 108 123
Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. For Operations below 200 RPM, an auxiliary lubrication system is required. Not all plunger sizes are shown. Contact National-Oilwell for additional information. *Spherical Valves must be installed when the pump is fitted with 4.0” (102mm) plungers The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
184T-7 Triplex Plunger Pump INTERNAL LUBE PUMP
Specifications PRESSURE GAUGE
22.01 13.01 TYP
D SUCTION
26.00 TYP
C DISCHARGE
30.24
ÿ 1.13 TYP 4 PLACES
ÿ
1.250 x .625 KEY WAY 10.125 LONG
4.500 4.499
DISCHARGE CONNECTION
ROTATION DIRECTION
G 1.50
1.50
A
26.17
13.75
B
H
1.25
SUCTION CONNECTION
6.50
11.74
Pump Size: maximum plunger size x stroke length, in.(mm): 5.750 x 7.125 (146.05 x 180.975) Rated BHP (kW) at 265 RPM: 184 (137) Rated plunger load, pounds (kg): 11580 (5253) Maximum discharge pressure: psi (kPa) “XL” model: 728 (5020) “L” model: 1204 (8299) “M” model: 2912 (20081) “H” model: 6000 (41369) Crankshaft extension: Diameter, in.(mm): 4.500 (114.3) Length, in.(mm): 12.250 (311.15) Keyway width x depth, in.(mm): 1.25 x 5/8 (31.75 x 15.75) Maximum recommended sheave diameter, in.(mm): 63 (1600.2) For larger sizes: Contact Factory Oil Capacity, gallons (L) Crankcase: 17 (64.35) Weight, pump only on wood shipping skids, pounds (kg) “XL” model: 4900 (2223) “L” model: 4600 (2087) “M” model: 4300 (1950) “H” model: 3800 (1724) Standard Materials for Fluid Ends: “XL” model Cast Duplex Stainless Steel Cast Carbon Steel “L” model Cast Nickel-Aluminum-Bronze Forged/Plate Carbon Steel “M” model Cast Nickel-Aluminum-Bronze Cast Duplex Stainless Steel Forged/Plate Carbon Steel “H” model Forged 15-5 Stainless Steel
34.50
E
F
Pump Model 184T-7XL 184T-7L 184T-7M 184T-7H
Flange Connections Discharge Connection Sizes Suction Connection Sizes 4 (101.6)-600# ANSI FF 10 (254.0)-150# ANSI FF 4 (101.6)-900# ANSI FF 6 (152.4)-150# ANSI FF 2.5 (63.5)-1500# ANSI FF 4 (101.6)-300# ANSI FF 2 (50.8)-2500# ANSI RTJ 4 (101.6)-300# ANSI RF
A 10 8 1/4 6 7/8 3 7/16
B 14 3/8 14 3/8 8 3/4 12 7/16
Dimensions (Inches) C D E F 34 36 48 3/8 72 33 33 46 3/4 71 34 36 48 3/8 71 31 33 53 5/16 68 3/8
G 16 5/8 13 1/4 16 5/8 11 1/2
H 7 1/4 1 -1 1/2 2 1/4
184T-7 Triplex Plunger Pump Performance Data PUMP
184T-7XL (HP250XL)
184T-7L (HP250BL)
184T-7M (HP250BM)
184T-7H (HP250BH)
PUMP
184T-7XL (HP250XL)
184T-7L (HP250BL)
184T-7M (HP250BM)
184T-7H (HP250BH)
English Units Plunger Plunger BPD Dia. Area per In. Sq. In. RPM 5.750 25.9672 82.3820 5.500 23.7583 75.3741 5.375 22.6906 71.9869 5.250 21.6475 68.6776 5.000 19.6349 62.2926 4.750 17.7205 56.2191 4.500 15.9043 50.4570 4.250 14.1862 45.0064 4.000 12.5664 39.8673 3.750 11.0447 35.0396 3.500 9.6211 30.5234 3.250 8.2958 26.3186 3.125 7.6699 24.3331 3.000 7.0686 22.4253 2.875 6.4918 20.5955 2.750 5.9396 18.8435 2.625 5.4119 17.1694 2.500 4.9087 15.5732 2.375 4.4301 14.0548 2.250 3.9761 12.6143 2.125 3.5466 11.2516 2.000 3.1416 9.9668 1.875 2.7612 8.7599 1.750 2.4053 7.6308 1.625 2.0739 6.5797 1.500 1.7671 5.6063 Brake Horsepower Required
GPM per RPM 2.4028 2.1984 2.0996 2.0031 1.8169 1.6397 1.4717 1.3127 1.1628 1.0220 0.8903 0.7676 0.7097 0.6541 0.6007 0.5496 0.5008 0.4542 0.4099 0.3679 0.3282 0.2907 0.2555 0.2226 0.1919 0.1635
Max. Press. PSI 446 487 510 535 590 653 728 816 922 1048 1204 1396 1510 1638 1784 1950 2140 2359 2614 2912 3265 3686 4194 4814 5584 6000
Metric Units Plunger Plunger Dia. Area mm cm2 146 167.530 140 153.279 137 146.391 133 139.661 127 126.677 121 114.326 114 102.608 108 91.524 102 81.073 95 71.256 89 62.072 83 53.521 79 49.483 76 45.604 73 41.883 70 38.320 67 34.915 64 31.669 60 28.581 57 25.652 54 22.881 51 20.268 48 17.814 44 15.518 41 13.380 38 11.401 Kilowatts Required
L/Sec. per RPM 0.1516 0.1387 0.1325 0.1264 0.1146 0.1035 0.0928 0.0828 0.0734 0.0645 0.0562 0.0484 0.0448 0.0413 0.0379 0.0347 0.0316 0.0287 0.0259 0.0232 0.0207 0.0183 0.0161 0.0140 0.0121 0.0103
100 * RPM 150 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 3075 54.6 15.2 81.9 22.7 3361 49.9 13.9 74.9 20.8 3519 47.7 13.2 71.5 19.9 3688 45.5 12.6 68.2 19.0 4066 41.3 11.5 61.9 17.2 4506 37.2 10.3 55.9 15.5 5020 33.4 9.3 50.1 13.9 5628 29.8 8.3 44.7 12.4 6354 26.4 7.3 39.6 11.0 7229 23.2 6.4 34.8 9.7 8299 20.2 5.6 30.3 8.4 9624 17.4 4.8 26.1 7.3 10410 16.1 4.5 24.2 6.7 11295 14.9 4.1 22.3 6.2 12299 13.6 3.8 20.5 5.7 13442 12.5 3.5 18.7 5.2 14753 11.4 3.2 17.1 4.7 16265 10.3 2.9 15.5 4.3 18022 9.3 2.6 14.0 3.9 20081 8.4 2.3 12.5 3.5 22512 7.5 2.1 11.2 3.1 25414 6.6 1.8 9.9 2.8 28916 5.8 1.6 8.7 2.4 33194 5.1 1.4 7.6 2.1 38498 4.4 1.2 6.5 1.8 41369 3.7 1.0 5.6 1.5 52 78
M3/Hr per RPM 0.5457 0.4993 0.4768 0.4549 0.4126 0.3724 0.3342 0.2981 0.2641 0.2321 0.2022 0.1743 0.1612 0.1485 0.1364 0.1248 0.1137 0.1032 0.0931 0.0836 0.0745 0.0660 0.0580 0.0505 0.0436 0.0371
100 * RPM
BPD 8239 7538 7199 6868 6230 5622 5046 4501 3987 3504 3053 2632 2434 2243 2060 1885 1717 1558 1406 1262 1126 997 876 764 658 561
GPM 240.3 219.8 210.0 200.3 181.7 164.0 147.2 131.3 116.3 102.2 89.0 76.8 71.0 65.4 60.1 55.0 50.1 45.4 41.0 36.8 32.8 29.1 25.5 22.3 19.2 16.4 70
150 RPM
BPD GPM 12358 360.4 11307 329.8 10799 314.9 10302 300.5 9344 272.5 8433 246.0 7569 220.7 6751 196.9 5981 174.4 5256 153.3 4579 133.5 3948 115.1 3650 106.5 3364 98.1 3090 90.1 2827 82.4 2576 75.1 2336 68.1 2109 61.5 1893 55.2 3067 49.2 2717 43.6 2388 38.3 2293 33.4 1977 28.8 1685 24.5 105
175 RPM
BPD 14417 13191 12598 12019 10902 9839 8830 7877 6977 6132 5342 4606 4259 3925 3605 3298 3005 2726 2460 2208 1970 1745 1533 1336 1152 982
GPM 420.5 384.7 367.4 350.5 318.0 287.0 257.5 229.7 203.5 178.8 155.8 134.3 124.2 114.5 105.1 96.2 87.6 79.5 71.7 64.4 57.4 50.9 44.7 38.9 33.6 28.6 122
175 RPM
M3/Hr 95.5 87.4 83.4 79.6 72.2 65.2 58.5 52.2 46.2 40.6 35.4 30.5 28.2 26.0 23.9 21.8 19.9 18.1 16.3 14.6 13.0 11.6 10.2 8.8 7.6 6.5
L/Sec. 26.5 24.3 23.2 22.1 20.1 18.1 16.2 14.5 12.8 11.3 9.8 8.5 7.8 7.2 6.6 6.1 5.5 5.0 4.5 4.1 3.6 3.2 2.8 2.5 2.1 1.8 91
200 RPM
BPD 16477 15075 14398 13736 12459 11244 10092 9002 7974 7008 6105 5264 4867 4486 4120 3769 3434 3115 2811 2523 2251 1994 1752 1527 1316 1122
GPM 480.6 439.7 419.9 400.6 363.4 327.9 294.3 262.5 232.6 204.4 178.1 153.5 141.9 130.8 120.1 109.9 100.2 90.8 82.0 73.6 65.6 58.1 51.1 44.5 38.4 32.7 139
200 RPM
M3/Hr 109.1 99.9 95.4 91.0 82.5 74.5 66.8 59.6 52.8 46.4 40.4 34.9 32.2 29.7 27.3 25.0 22.7 20.6 18.6 16.7 14.9 13.2 11.6 10.1 8.7 7.4
225 RPM
BPD 18536 16960 16198 15453 14016 12650 11353 10127 8971 7884 6868 5922 5475 5046 4634 4240 3864 3504 3163 2839 2532 2243 1971 1717 1481 1262
GPM 540.6 494.6 472.4 450.7 408.8 368.9 331.1 295.4 261.6 229.9 200.3 172.7 159.7 147.2 135.2 123.7 112.7 102.2 92.2 82.8 73.8 65.4 57.5 50.1 43.2 36.8 157
225 RPM
265 RPM
BPD 21832 19975 19077 18200 16508 14899 13372 11927 10565 9286 8089 6975 6449 5943 5458 4994 4550 4127 3725 3343 2982 2642 2322 2023 1744 1486
GPM 636.7 582.6 556.4 530.8 481.5 434.5 390.0 347.9 308.1 270.8 235.9 203.4 188.1 173.3 159.2 145.6 132.7 120.4 108.6 97.5 87.0 77.0 67.7 59.0 50.9 43.3 184
265 RPM
L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. 30.3 122.8 34.1 144.6 40.2 27.7 112.3 31.2 132.3 36.8 26.5 107.3 29.8 126.4 35.1 25.3 102.4 28.4 120.5 33.5 22.9 92.8 25.8 109.3 30.4 20.7 83.8 23.3 98.7 27.4 18.6 75.2 20.9 88.6 24.6 16.6 67.1 18.6 79.0 21.9 14.7 59.4 16.5 70.0 19.4 12.9 52.2 14.5 61.5 17.1 11.2 45.5 12.6 53.6 14.9 9.7 39.2 10.9 46.2 12.8 9.0 36.3 10.1 42.7 11.9 8.3 33.4 9.3 39.4 10.9 7.6 30.7 8.5 36.2 10.0 6.9 28.1 7.8 33.1 9.2 6.3 25.6 7.1 30.1 8.4 5.7 23.2 6.4 27.3 7.6 5.2 20.9 5.8 24.7 6.9 4.6 18.8 5.2 22.1 6.2 4.1 16.8 4.7 19.7 5.5 3.7 14.9 4.1 17.5 4.9 3.2 13.1 3.6 15.4 4.3 2.8 11.4 3.2 13.4 3.7 2.4 9.8 2.7 11.5 3.2 2.1 8.4 2.3 9.8 2.7 104 117 137
Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. *Operation below 150 RPM requires an “optional” externally-mounted electric motor-driven auxillary lubrication system. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
200T-5 Triplex Plunger Pump 5 11/16 11 1/8
9 1/4
4.875 4.873
Specifications
7/8 " x 7/16 KEYWAY 3.500 3.499
DIA.
DIA. 1 1/4 " x 5/8 " KEYWAY
30 5/8
SUCTION AND DISCHARGE CONNECTIONS MAY BE MADE AT EITHER END
18 5/16
7 1/2
"C"
55 1/2
7 1/2
13 1/8
13 1/8
6 5 5/8
7
SHAFT EXTENSION FOR DIRECT DRIVE
1 1/8 " DIA. HOLE THRU 4 PLACES, AS SHOWN
1 1/4 " x 5/8 " KEYWAY 4.875 4.873
DIA.
16 3/4
"D" 36 1/2
31 1/4
CENTERLINE DISCHARGE
"B"
6
7 9
12 1/4 4 1/2
1 1/2 " STD. PIPE TAP MUD TRAP DRAIN 3 3/4
7 3/4
19 3/4
"F"
CENTERLINE SUCTION
2 1/4
1" STD. PIPE TAP POWER END OIL DRAIN
"A"
1 1/2 " STD. PIPE TAP CRADLE DRAIN, BOTH SIDES
Pump Size maximum plunger size x stroke length in.(mm): 4 x 5 (102 x 127) Rated bhp at 400 rpm (kw): 200 (149.1) Rated plunger load, pounds(Kg): 11,870(5384.2) Maximum discharge pressure: psi(kPa) “L” model: 1680 (11,583) “M” model: 3350 (23097) “H” model: 5000 (34,474) Crankshaft extension: in.(mm) Diameter: 4.875 (123.8) Length long side: 11.75 (298.0) Length short side: 5-5/8 (142.9) Keyway (width x depth): 1 1/4 x 5/8 (32 x 16) Maximum recommended sheave in.(mm): 58 (1473) Minimum recommended sheave in.(mm): 36 (914) For larger sizes: Contact Customer Service Pinion shaft extension, if gear reducer is supplied in.(mm) For belt or chain drive: Contact Customer Service For direct drive: Diameter: 3.5 (88.9) Length: 5-11/16 (144.5) Keyway (width x depth): 7/8 x 7/16 (22.2 x 11.1) Accessory gear reduction unit: 2.27:1, 2.89:1, 3.25:1, 3.36:1, 3.69:1, 4.38:1, 4.84:1, 5.63:1 Oil Capacity, gallons (L) Crankcase: 6 1/2 (24.6) Gear Reducer-varies with ratio: 3.5 to 6.5 (13.2 to 24.6) Weight, pump only on wood shipping skids pounds (Kg): 4486 (2035) Gear reducer, approximate pounds (Kg): 1100 (499)
2" STD. PIPE TAP CRADLE DRAIN
40 3/4 "E"
Pump Model 200T-5L 200T-5M 200T-5H
Flange Connections Discharge Connection Sizes Suction Connection Sizes 3 (76.2) API-2000 RJ 6 (152.4) ANSI-150 FF 2 (50.8) API-5000 RJ 4 (101.6) ANSI-150 FF 2 (50.8) ANSI-2500 RJ 3 (76.2) API-2000 RJ
A 5 11/16 4 3/4 4 3/4
Dimensions in inches B C D 7 5/8 27 3/4 48 3/4 6 1/2 26 1/2 48 3/8 6 1/2 26 1/2 48 3/8
(mm) E 65 3/4 64 7/8 64 1/4
F 23 25 5/16 25 5/16
200T-5 Triplex Plunger Pump Performance Data PUMP
200T-5L
200T-5M
200T-5H
PUMP
200T-5L
200T-5M
200T-5H
English Units Plunger Plunger BPD Dia. Area per In. Sq. In. RPM 4.000 12.5664 27.9770 3.750 11.0447 24.5892 3.500 9.6211 21.4199 3.250 8.2958 18.4692 3.000 7.0686 15.7371 2.750 5.9396 13.2235 2.625 5.4119 12.0487 2.500 4.9087 10.9285 2.375 4.4301 9.8630 2.250 3.9761 8.8521 2.125 3.5466 7.8959 2.000 3.1416 6.9943 1.875 2.7612 6.1473 1.750 2.4053 5.3550 1.375 1.4849 3.3059 1.250 1.2272 2.7321 Brake Horsepower Required
GPM per RPM 0.8160 0.7172 0.6247 0.5387 0.4590 0.3857 0.3514 0.3187 0.2877 0.2582 0.2303 0.2040 0.1793 0.1562 0.0964 0.0797
Metric Units Plunger Plunger Dia. Area mm cm2 102 81.073 95 71.256 89 62.072 83 53.521 76 45.604 70 38.320 67 34.915 64 31.669 60 28.581 57 25.652 54 22.881 51 20.268 48 17.814 44 15.518 35 9.580 32 7.917 Kilowatts Required
L/Sec. per RPM 0.0515 0.0452 0.0394 0.0340 0.0290 0.0243 0.0222 0.0201 0.0181 0.0163 0.0145 0.0129 0.0113 0.0099 0.0061 0.0050
M3/Hr per RPM 0.1853 0.1629 0.1419 0.1223 0.1042 0.0876 0.0798 0.0724 0.0653 0.0586 0.0523 0.0463 0.0407 0.0355 0.0219 0.0181
100 RPM Max. Press. PSI 945 1075 1234 1431 1680 1998 2193 2418 2679 2985 3350 3778 4299 4935 5000 5000
BPD 2798 2459 2142 1847 1574 1323 1205 1093 987 886 790 700 615 536 331 274
GPM 81.6 71.7 62.5 53.9 45.9 38.6 35.1 31.9 28.8 25.8 23.0 20.4 17.9 15.6 9.6 8.0 50
200 RPM
BPD 5596 4918 4284 3694 3148 2645 2410 2186 1973 1771 1580 1399 1230 1071 662 547
250 RPM
GPM 163.2 143.4 124.9 107.7 91.8 77.1 70.3 63.7 57.5 51.6 46.1 40.8 35.9 31.2 19.3 15.9 100
BPD 6995 6148 5355 4618 3935 3306 3013 2733 2466 2214 1974 1749 1537 1339 827 684
GPM 204.0 179.3 156.2 134.7 114.7 96.4 87.9 79.7 71.9 64.5 57.6 51.0 44.8 39.0 24.1 19.9
300 RPM
BPD 8394 7377 6426 5541 4722 3968 3615 3279 2959 2656 2369 2099 1845 1607 992 820
125
100 RPM 200 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 6513 18.5 5.1 37.1 10.3 7410 16.3 4.5 32.6 9.0 8506 14.2 3.9 28.4 7.9 9865 12.2 3.4 24.5 6.8 11583 10.4 2.9 20.8 5.8 13779 8.8 2.4 17.5 4.9 15123 8.0 2.2 16.0 4.4 16673 7.2 2.0 14.5 4.0 18474 6.5 1.8 13.1 3.6 20583 5.9 1.6 11.7 3.3 23097 5.2 1.5 10.5 2.9 26051 4.6 1.3 9.3 2.6 29640 4.1 1.1 8.1 2.3 34026 3.5 1.0 7.1 2.0 34474 2.2 0.6 4.4 1.2 34474 1.8 0.5 3.6 1.0 37 75
250 RPM
M3/Hr 46.3 40.7 35.5 30.6 26.1 21.9 20.0 18.1 16.3 14.7 13.1 11.6 10.2 8.9 5.5 4.5
L/Sec. 12.9 11.3 9.9 8.5 7.2 6.1 5.5 5.0 4.5 4.1 3.6 3.2 2.8 2.5 1.5 1.3 93
GPM 244.8 215.2 187.4 161.6 137.7 115.7 105.4 95.6 86.3 77.5 69.1 61.2 53.8 46.9 28.9 23.9 150
300 RPM
M3/Hr 55.6 48.9 42.6 36.7 31.3 26.3 23.9 21.7 19.6 17.6 15.7 13.9 12.2 10.6 6.6 5.4
350 RPM
BPD 9792 8607 7497 6465 5508 4629 4218 3825 3453 3099 2764 2448 2152 1875 1158 957
GPM 285.6 251.0 218.7 188.5 160.6 135.0 123.0 111.6 100.7 90.4 80.6 71.4 62.8 54.7 33.7 27.9 175
350 RPM
400 RPM
BPD GPM 11191* 326* 9836 286.9 8568 249.9 7388 215.5 6295 183.6 5290 154.3 4820 140.6 4372 127.5 3946 115.1 3541 103.3 3159 92.1 2798 81.6 2459 71.7 2142 62.5 1323 38.6 1093 31.9 200
400 RPM
L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. 15.4 64.9 18.0 74.1* 20.6* 13.6 57.0 15.8 65.1 18.1 11.8 49.7 13.8 56.8 15.8 10.2 42.8 11.9 48.9 13.6 8.7 36.5 10.1 41.7 11.6 7.3 30.7 8.5 35.0 9.7 6.7 27.9 7.8 31.9 8.9 6.0 25.3 7.0 29.0 8.0 5.4 22.9 6.4 26.1 7.3 4.9 20.5 5.7 23.5 6.5 4.4 18.3 5.1 20.9 5.8 3.9 16.2 4.5 18.5 5.1 3.4 14.3 4.0 16.3 4.5 3.0 12.4 3.4 14.2 3.9 1.8 7.7 2.1 8.8 2.4 1.5 6.3 1.8 7.2 2.0 112 130 149
Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. For Operations below 200 RPM, an auxiliary lubrication system is required. Not all plunger sizes are shown. Contact National-Oilwell for additional information. Spherical Valves must be installed when the pump is fitted with 4.0” (102mm) plungers The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
202T-6 Triplex Plunger Pump 1.250
Specifications
DIA. AUXILIARY DRIVE SHAFT 1" DIA. HOLE THRU 4 PLACES AS SHOWN
2 3/4 25 1/2 21 1/4 E FACE OF SUCTION
12
F FACE OF DISCHARGE
24 51 1/2 E FACE OF SUCTION 26 6 1/2 4
5 1/2 8 3/4
1" x 3/8" KEYWAY
4.495
4 1/2
DIA
12" TO REMOVE VALVES
D C 14 1/4 3/8 B 24
4 11 1/2
2 1/2
5 1/2
A
39 51
7 5/8
16" TO REMOVE PLUNGERS
73 1/8 9" TO REMOVE CONNECTING RODS AND CROSSHEADS
Pump Model 202T-6L 202T-6M 202T-6H
F FACE OF DISCHARGE
Pump Size maximum plunger size x stroke length, in.(mm): 4 1/4 x 6 (107.9 x 152.4) Rated bhp at 320 rpm (kw): 202 (150.58) Rated plunger load, pounds(Kg): 12,500(5670) Maximum discharge pressure: psi(kPa) “L” model: 1500 (10,342) “M” model: 3180 (21,925) Crankshaft extension: in.(mm) Diameter: 4.495 (114.17) Length: 8 3/4 (222.25) Keyway (width x depth): 1 x 3/8 (25.4 x 9.53) Maximum recommended sheave, in.(mm): 58 (1473) Minimum recommended sheave, in.(mm): 36 (914) For larger sizes: Contact Customer Service Pinion shaft extension, if gear reducer is supplied, in.(mm) For belt or chain drive: Contact Customer Service For direct drive: Diameter: 3.438 (87.33) Length: 7 3/8 (187.33) Keyway (width x depth): 7/8 x 7/16 (22.2 x 11.1) Accessory gear reduction unit: 1.59:1, 1.78:1, 2.487:1, 3.12:1, 4.44:1, 5.48:1 Oil Capacity, gallons (L) Crankcase: 34 (128.7) Gear Reducer: Varies with ratio Weight, pump only on wood shipping skids pounds (Kg): 3952 (1792.60)
2"NPT CRADLE DRAIN (BOTH SIDES)
Flange Connections Discharge Connection Sizes Suction Connection Sizes 3” ANSI-600 L.R. 6” ANSI-150 F.F. 2 1/2” ANSI-1500 L.R. 4” ANSI-150 F.F. 2” SCH. 160 PIPE BEVELED FOR WELD 4” ANSI-300 R.F.
A 1 3/4 2 1/2
Dimensions (Inches) B C D E 3 3/4 22 1/4 28 5/8 13 1/2 5 3/4 22 28 1/4 16 3 22 1/4 28 5/8 17
F 13 1/2 16 18 1/4
202T-6 Triplex Plunger Pump Performance Data PUMP
202T-6L
202T-6M
PUMP
202T-6L
202T-6M
English Units Plunger Plunger BPD Dia. Area per In. Sq. In. RPM 4.250 14.1862 37.9001 4.125 13.3640 35.7035 4.000 12.5664 33.5725 3.875 11.7932 31.5070 3.750 11.0447 29.5070 3.625 10.3206 27.5727 3.500 9.6211 25.7039 3.375 8.9462 23.9007 3.250 8.2958 22.1631 3.125 7.6699 20.4910 3.000 7.0686 18.8845 3.000 7.0686 18.8845 2.875 6.4918 17.3436 2.750 5.9396 15.8682 2.625 5.4119 14.4584 2.500 4.9087 13.1142 2.000 3.1416 8.3931 Brake Horsepower Required
GPM per RPM 1.1054 1.0414 0.9792 0.9190 0.8606 0.8042 0.7497 0.6971 0.6464 0.5977 0.5508 0.5508 0.5059 0.4628 0.4217 0.3825 0.2448
Metric Units Plunger Plunger Dia. Area mm cm2 108 91.524 105 86.219 102 81.073 98 76.085 95 71.256 92 66.584 89 62.072 86 57.717 83 53.521 79 49.483 76 45.604 76 45.604 73 41.883 70 38.320 67 34.915 64 31.669 51 20.268 Kilowatts Required
L/Sec. per RPM 0.0697 0.0657 0.0618 0.0580 0.0543 0.0507 0.0473 0.0440 0.0408 0.0377 0.0347 0.0347 0.0319 0.0292 0.0266 0.0241 0.0154
M3/Hr per RPM 0.2510 0.2365 0.2224 0.2087 0.1954 0.1826 0.1703 0.1583 0.1468 0.1357 0.1251 0.1251 0.1149 0.1051 0.0958 0.0869 0.0556
100 RPM Max. Press. PSI 881 935 995 1060 1132 1211 1299 1397 1500 1500 1500 1768 1926 2105 2310 2546 3180
BPD 3791 3571 3358 3151 2951 2758 2571 2391 2217 2050 1889 1889 1735 1587 1446 1312 840
GPM 110.5 104.1 97.9 91.9 86.1 80.4 75.0 69.7 64.6 59.8 55.1 55.1 50.6 46.3 42.2 38.2 24.5 64
150 RPM
BPD 5686 5356 5036 4727 4427 4136 3856 3586 3325 3074 2833 2833 2602 2381 2169 1968 1259
200 RPM
GPM 165.8 156.2 146.9 137.8 129.1 120.6 112.5 104.6 97.0 89.6 82.6 82.6 75.9 69.4 63.3 57.4 36.7
BPD 7581 7141 6715 6302 5902 5515 5141 4781 4433 4099 3777 3777 3469 3174 2892 2623 1679
81
100 RPM 150 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 6075 25.1 7.0 37.7 10.5 6449 23.6 6.6 35.5 9.9 6858 22.2 6.2 33.4 9.3 7308 20.9 5.8 31.3 8.7 7803 19.5 5.4 29.3 8.1 8351 18.3 5.1 27.4 7.6 8958 17.0 4.7 25.5 7.1 9634 15.8 4.4 23.7 6.6 10342 14.7 4.1 22.0 6.1 10342 13.6 3.8 20.4 5.7 10342 12.5 3.5 18.8 5.2 12193 12.5 3.5 18.8 5.2 13276 11.5 3.2 17.2 4.8 14510 10.5 2.9 15.8 4.4 15925 9.6 2.7 14.4 4.0 17557 8.7 2.4 13.0 3.6 21925 5.6 1.5 8.3 2.3 48 60
GPM 221.1 208.3 195.8 183.8 172.1 160.8 149.9 139.4 129.3 119.5 110.2 110.2 101.2 92.6 84.3 76.5 49.0 127
200 RPM
M3/Hr 50.2 47.3 44.5 41.7 39.1 36.5 34.1 31.7 29.4 27.1 25.0 25.0 23.0 21.0 19.2 17.4 11.1
L/Sec. 13.9 13.1 12.4 11.6 10.9 10.1 9.5 8.8 8.2 7.5 6.9 6.9 6.4 5.8 5.3 4.8 3.1 95
250 RPM
BPD 9476 8926 8394 7877 7377 6894 6426 5976 5541 5123 4722 4722 4336 3968 3615 3279 2099
GPM 276.4 260.3 244.8 229.7 215.2 201.1 187.4 174.3 161.6 149.4 137.7 137.7 126.5 115.7 105.4 95.6 61.2 158
250 RPM
M3/Hr 62.8 59.1 55.6 52.2 48.9 45.7 42.6 39.6 36.7 33.9 31.3 31.3 28.7 26.3 23.9 21.7 13.9
300 RPM
BPD 11371 10712 10072 9453 8853 8272 7712 7171 6649 6148 5666 5666 5204 4761 4338 3935 2518
GPM 331.6 312.4 293.8 275.7 258.2 241.3 224.9 209.1 193.9 179.3 165.2 165.2 151.8 138.8 126.5 114.7 73.4 189
300 RPM
320 RPM
BPD GPM 12129 353.7 11426 333.2 10744 313.3 10083 294.1 9443 275.4 8824 257.3 8226 239.9 7649 223.1 7093 206.9 6558 191.2 6044 176.3 6044 176.3 5550 161.9 5078 148.1 4627 134.9 4197 122.4 2686 78.3 202
320 RPM
L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. 17.4 75.3 20.9 80.3 22.3 16.4 70.9 19.7 75.7 21.0 15.4 66.7 18.5 71.2 19.8 14.5 62.6 17.4 66.8 18.6 13.6 58.6 16.3 62.5 17.4 12.7 54.8 15.2 58.4 16.2 11.8 51.1 14.2 54.5 15.1 11.0 47.5 13.2 50.7 14.1 10.2 44.0 12.2 47.0 13.1 9.4 40.7 11.3 43.4 12.1 8.7 37.5 10.4 40.0 11.1 8.7 37.5 10.4 40.0 11.1 8.0 34.5 9.6 36.8 10.2 7.3 31.5 8.8 33.6 9.3 6.7 28.7 8.0 30.6 8.5 6.0 26.1 7.2 27.8 7.7 3.9 16.7 4.6 17.8 4.9 118 141 151
Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. Not all plunger sizes are shown. Contact National-Oilwell for additional information. For Operations below 120 RPM, an auxiliary lubrication system is required. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
217Q-4 Quintuplex Plunger Pump INTERNAL LUBE PUMP
Specifications
PRESSURE GAUGE
25.29
14.00 TYP
C 28.00 TYP
C/2 19.22
ÿ.75 TYP 4 PLACES
10.50
1.000 x .500 KEYWAY 9.000 LONG
ÿ 4.250 4.249
ROTATION DIRECTION
DISCHARGE CONNECTION
F A 20.42
1.00
B
10.00
Pump Size: maximum plunger size x stroke length, in.(mm): 3.375 x 4.500 (85.725 x 114.3) Rated BHP (kW) at 390 RPM: 217 (162) Rated plunger load, pounds (kg): 8800(3992) Maximum discharge pressure: psi (kPa) “L” model: 1440 (9929) “M” model: 3600 (24821) “H” model: 6000 (41369) Crankshaft extension: Diameter, in.(mm): 4.250 (107.95) Length, in.(mm): 10.50 (266.7) Keyway width x depth, in.(mm): 1 x 1/2 (25.4 x 38.1) Maximum recommended sheave diameter, in.(mm): 53 (1346.2) For larger sizes: Contact Customer Service Pinion shaft extension, if gear reducer is supplied, in.(mm) For belt or chain drive: N/A For direct drive: Diameter: 2.500 (63.5) Length: 5.000 (127.0) Keyway (width x length): 5/8 x 5/16 (15.88 x7.94) Accessory gear reduction unit: 2.06:1, 2.26:1, 3.60:1, 4.25:1, 4.65:1, 4.88:1, 5.13:1, 5.40:1, 5.69:1 Oil Capacity, gallons (L) Crankcase: 7 (26.5) Gear Reducer - varies with ratio: 2.00 to 2.25 (7.57 to 8.52) Weight, pump only on wood shipping skids, pounds (kg): 2948 (1337) Standard Materials for Fluid Ends: “L” & “M” models Cast Nickel-Aluminum-Bronze Cast Duplex Stainless Steel Forged/Plate Carbon Steel “H” model Forged/Plate Carbon Steel Forged 15-5 Stainless Steel Forged Nickel-Aluminum-Bronze
G .75
SUCTION CONNECTION
5.25
24.25
9.89
D
E
Pump Model 217Q-4L 217Q-4M 217Q-4H
Flange Connections Discharge Connection Sizes Suction Connection Sizes 3 (76.2)-600# ANSI FF 6 (152.4)-150# ANSI FF 2 (50.8)-1500# ANSI FF 4 (101.6)-300# ANSI FF 2 (50.8)-11 1/2 NPT 3 (76.2)-8 NPT
A 4 5/8 5 1/16 5 1/16
Dimensions (Inches) B C D E 7 7/8 33 33 3/8 49 7/16 5 7/8 33 33 38 3/4 6 3/16 31 1/2 33 39 3/4
F 9 5/8 9 1/2 10 3/4
G 3 3/8 7/8 -1 5/8
217Q-4 Quintuplex Plunger Pump Performance Data PUMP
217Q-4L (HP200AL)
217Q-4M (HP200AM)
217Q-4H (HP200MS)
PUMP
217Q-4L (HP200AL)
217Q-4M (HP200AM)
217Q-4H (HP200MS)
English Units Plunger Plunger BPD Dia. Area per In. Sq. In. RPM 3.375 8.9462 29.8759 3.250 8.2958 27.7038 3.125 7.6699 25.6137 3.000 7.0686 23.6056 2.875 6.4918 21.6795 2.750 5.9396 19.8353 2.625 5.4119 18.0731 2.500 4.9087 16.3928 2.375 4.4301 14.7945 2.250 3.9761 13.2782 2.125 3.5466 11.8438 2.000 3.1416 10.4914 1.875 2.7612 9.2209 1.750 2.4053 8.0325 1.625 2.0739 6.9260 1.500 1.7671 5.9014 1.375 1.4849 4.9588 1.250 1.2272 4.0982 Brake Horsepower Required
GPM per RPM 0.8714 0.8080 0.7471 0.6885 0.6323 0.5785 0.5271 0.4781 0.4315 0.3873 0.3454 0.3060 0.2689 0.2343 0.2020 0.1721 0.1446 0.1195
Metric Units Plunger Plunger Dia. Area mm cm2 86 57.717 83 53.521 79 49.483 76 45.604 73 41.883 70 38.320 67 34.915 64 31.669 60 28.581 57 25.652 54 22.881 51 20.268 48 17.814 44 15.518 41 13.380 38 11.401 35 9.580 32 7.917 Kilowatts Required
L/Sec. per RPM 0.0550 0.0510 0.0471 0.0434 0.0399 0.0365 0.0333 0.0302 0.0272 0.0244 0.0218 0.0193 0.0170 0.0148 0.0127 0.0109 0.0091 0.0075
M3/Hr per RPM 0.1979 0.1835 0.1697 0.1564 0.1436 0.1314 0.1197 0.1086 0.0980 0.0880 0.0785 0.0695 0.0611 0.0532 0.0459 0.0391 0.0328 0.0271
100 * RPM Max. Press. PSI 984 1061 1147 1245 1356 1440 1440 1793 1986 2213 2481 2801 3187 3600 4243 4980 5926 6000
BPD 2988 2771 2562 2361 2168 1984 1808 1640 1480 1328 1185 1050 923 804 693 591 496 410
GPM 87.1 80.8 74.7 68.8 63.2 57.9 52.7 47.8 43.2 38.7 34.5 30.6 26.9 23.4 20.2 17.2 14.5 12.0 56
150 RPM
BPD 4482 4156 3843 3541 3252 2976 2711 2459 2220 1992 1777 1574 1384 1205 1039 886 744 615
200 RPM
GPM 130.7 121.2 112.1 103.3 94.8 86.8 79.1 71.7 64.7 58.1 51.8 45.9 40.3 35.1 30.3 25.8 21.7 17.9
BPD 5976 5541 5123 4722 4336 3968 3615 3279 2959 2656 2369 2099 1845 1607 1386 1181 992 820
84
GPM 174.3 161.6 149.4 137.7 126.5 115.7 105.4 95.6 86.3 77.5 69.1 61.2 53.8 46.9 40.4 34.4 28.9 23.9
250 RPM
BPD 7469 6926 6404 5902 5420 4959 4519 4099 3699 3320 2961 2623 2306 2009 1732 1476 1240 1025
112
100 * RPM 150 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 6782 19.8 5.5 29.7 8.2 7314 18.4 5.1 27.5 7.6 7911 17.0 4.7 25.4 7.1 8584 15.6 4.3 23.5 6.5 9346 14.4 4.0 21.5 6.0 9929 13.1 3.6 19.7 5.5 9929 12.0 3.3 18.0 5.0 12360 10.9 3.0 16.3 4.5 13696 9.8 2.7 14.7 4.1 15260 8.8 2.4 13.2 3.7 17108 7.8 2.2 11.8 3.3 19313 6.9 1.9 10.4 2.9 21974 6.1 1.7 9.2 2.5 24821 5.3 1.5 8.0 2.2 29256 4.6 1.3 6.9 1.9 34335 3.9 1.1 5.9 1.6 40861 3.3 0.9 4.9 1.4 41369 2.7 0.8 4.1 1.1 42 63
200 RPM
M3/Hr 39.6 36.7 33.9 31.3 28.7 26.3 23.9 21.7 19.6 17.6 15.7 13.9 12.2 10.6 9.2 7.8 6.6 5.4
L/Sec. 11.0 10.2 9.4 8.7 8.0 7.3 6.7 6.0 5.4 4.9 4.4 3.9 3.4 3.0 2.5 2.2 1.8 1.5 84
GPM 217.8 202.0 186.8 172.1 158.1 144.6 131.8 119.5 107.9 96.8 86.4 76.5 67.2 58.6 50.5 43.0 36.2 29.9 139
250 RPM
M3/Hr 49.5 45.9 42.4 39.1 35.9 32.8 29.9 27.1 24.5 22.0 19.6 17.4 15.3 13.3 11.5 9.8 8.2 6.8
300 RPM
BPD 8963 8312 7685 7082 6504 5951 5422 4918 4439 3984 3554 3148 2767 2410 2078 1771 1488 1230
GPM 261.4 242.4 224.1 206.5 189.7 173.6 158.1 143.4 129.5 116.2 103.6 91.8 80.7 70.3 60.6 51.6 43.4 35.9 167
300 RPM
390 RPM
BPD GPM 11652 339.8 10805 315.1 9990 291.4 9207 268.5 8455 246.6 7736 225.6 7049 205.6 6394 186.5 5770 168.3 5179 151.0 4620 134.7 4092 119.3 3597 104.9 3133 91.4 2702 78.8 2302 67.1 1934 56.4 1599 46.6 217
390 RPM
L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. 13.7 59.4 16.5 77.2 21.4 12.7 55.1 15.3 71.6 19.9 11.8 50.9 14.1 66.2 18.4 10.9 46.9 13.0 61.0 16.9 10.0 43.1 12.0 56.0 15.6 9.1 39.4 10.9 51.2 14.2 8.3 35.9 10.0 46.7 13.0 7.5 32.6 9.0 42.3 11.8 6.8 29.4 8.2 38.2 10.6 6.1 26.4 7.3 34.3 9.5 5.4 23.5 6.5 30.6 8.5 4.8 20.8 5.8 27.1 7.5 4.2 18.3 5.1 23.8 6.6 3.7 16.0 4.4 20.7 5.8 3.2 13.8 3.8 17.9 5.0 2.7 11.7 3.3 15.2 4.2 2.3 9.9 2.7 12.8 3.6 1.9 8.1 2.3 10.6 2.9 104 124 162
Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. *Operation below 150 RPM requires an “optional” externallymounted electric motor-driven auxillary lubrication system. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
250T-5 Triplex Plunger Pump Specifications
7/8" X 7/16" KEYWAY 5 11/16 9 1/4
3.500 3.499
11 1/8
4.875 4.873
DIA.
DIA. 1 1/4" X 5/8" KEYWAY
30 5/8
SUCTION AND DISCHARGE CONNECTIONS MAY BE MADE AT EITHER END
18 5/16 13 1/8
"C"
55 1/2
7 1/2
7 1/2 13 1/8
6
1 1/8" DIA. HOLE THRU
7 5 5/8
4.875 4.873
SHAFT EXTENSION FOR DIRECT DRIVE
4 PLACES, AS SHOWN
1 1/4" X 5/8"KEYWAY
DIA.
16 3/4
"D" 36 1/2 1 1/2" STD. PIPE TAP CRADLE DRAIN, BOTH SIDES
+ +
+
+ CENTERLINE SUCTION
+
"B"
6"
+
+
12 1/4
+
+
9"
7
+ 2 1/4
CENTERLINE DISCHARGE "A"
+
+
31 1/4
+
+
+
+
+ 1 1/2" STD. PIPE TAP MUD TRAP DRAIN 3 3/4
1" STD. PIPE TAP POWER END OIL DRAIN
+
4 1/2
"F"
+
Pump Size maximum plunger size x stroke length, in.(mm): 4 1/2 x 5 (114 x 127) Rated bhp at 400 rpm (kw): 250 (187) Rated plunger load, pounds(Kg): 14855(6738) Maximum discharge pressure: psi(kPa) “L” model: 1544 (10646) “M” model: 3026 (20,865) “H” model: 5000 (3,474) Crankshaft extension: in.(mm) Diameter: 4.875 (123.8) Length long side: 11.75 (298.0) Length short side: 5 5/8 (142.9) Keyway (width x depth): 1 1/4 x 5/8 (32 x 16) Maximum recommended sheave in.(mm): 58 (1473) Minimum recommended sheave in.(mm): 36 (914) For larger sizes: Contact Customer Service Pinion shaft extension, if gear reducer is supplied, in.(mm) For belt or chain drive: Contact Customer Service For direct drive: Diameter: 3.5 (988.9) Length: 5 11/16 (114.5) Keyway (width x depth): 7/8 x 7/16 ((22.2 x 11.1) Accessory gear reduction unit: 2.27:1, 2.89:1, 3.25:1, 3.36:1, 3.69:1, 4.38:1, 4.84:1, 5.63:1 Oil Capacity, gallons (L) Crankcase: 6 1/2 (24.6) Gear Reducer-varies with ratio: 3.5 to 6.5 (13.2 to 24.6) Weight, pump only on wood shipping skids, pounds (Kg): 4486 (2035) Gear reducer, approximate pounds, (Kg): 1100 (499)
7 3/4
19 3/4
2" STD. PIPE TAP CRADLE DRAIN
40 3/4 "E"
Pump Model 250T-5L 250T-5M 250T-5H
Flange Connections Discharge Connection Sizes Suction Connection Sizes 3 (76.2) API-2000 RJ 6 (152.4) ANSI-150 FF 2 (50.8) API-5000 RJ 4 (101.6) ANSI-150 FF 2 (50.8) ANSI-2500 RJ 3 (76.2) API-2000 RJ
A 5 11/16 4 3/4 4 3/4
Dimensions in inches (mm) B C D E 7 5/8 27 3/4 48 3/4 65 3/4 6 1/2 26 1/2 48 3/8 64 7/8 6 1/2 26 1/2 48 3/8 64 1/4
F 23 25 5/16 25 5/16
250T-5 Triplex Plunger Pump Performance Data PUMP
250T-5L
250T-5M
250T-5H
PUMP
250T-5L
250T-5M
250T-5H
English Units Plunger Plunger BPD Dia. Area per In. Sq. In. RPM 4.500 15.9043 35.4084 4.250 14.1862 31.5835 4.000 12.5664 27.9770 3.750 11.0447 24.5892 3.500 9.6211 21.4199 3.250 8.2958 18.4692 3.000 7.0686 15.7371 2.750 5.9396 13.2235 2.500 4.9087 10.9285 2.250 3.9761 8.8521 2.125 3.5466 7.8959 2.000 3.1416 6.9943 1.875 2.7612 6.1473 Brake Horsepower Required
GPM per RPM 1.0327 0.9212 0.8160 0.7172 0.6247 0.5387 0.4590 0.3857 0.3187 0.2582 0.2303 0.2040 0.1793
Metric Units Plunger Plunger Dia. Area mm cm2 114 102.608 108 91.524 102 81.073 95 71.256 89 62.072 83 53.521 76 45.604 70 38.320 64 31.669 57 25.652 54 22.881 51 20.268 48 17.814 Kilowatts Required
L/Sec. per RPM 0.0652 0.0581 0.0515 0.0452 0.0394 0.0340 0.0290 0.0243 0.0201 0.0163 0.0145 0.0129 0.0113
M3/Hr per RPM 0.2345 0.2092 0.1853 0.1629 0.1419 0.1223 0.1042 0.0876 0.0724 0.0586 0.0523 0.0463 0.0407
100 RPM Max. Press. PSI 934 1047 1182 1345 1544 1791 2102 2501 3026 3736 4189 4728 5000
BPD 3541 3159 2798 2459 2142 1847 1574 1323 1093 886 790 700 615
GPM 103.3 92.1 81.6 71.7 62.5 53.9 45.9 38.6 31.9 25.8 23.0 20.4 17.9 63
200 RPM
BPD 7082 6317 5596 4918 4284 3694 3148 2645 2186 1771 1580 1399 1230
250 RPM
GPM 206.5 184.2 163.2 143.4 124.9 107.7 91.8 77.1 63.7 51.6 46.1 40.8 35.9 126
BPD 8853 7896 6995 6148 5355 4618 3935 3306 2733 2214 1974 1749 1537
GPM 258.2 230.3 204.0 179.3 156.2 134.7 114.7 96.4 79.7 64.5 57.6 51.0 44.8
300 RPM
BPD 10623 9476 8394 7377 6426 5541 4722 3968 3279 2656 2369 2099 1845
157
100 RPM 200 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 6440 23.5 6.5 46.9 13.0 7220 20.9 5.8 41.8 11.6 8151 18.5 5.1 37.1 10.3 9273 16.3 4.5 32.6 9.0 10646 14.2 3.9 28.4 7.9 12346 12.2 3.4 24.5 6.8 14490 10.4 2.9 20.8 5.8 17244 8.8 2.4 17.5 4.9 20865 7.2 2.0 14.5 4.0 25760 5.9 1.6 11.7 3.3 28879 5.2 1.5 10.5 2.9 32602 4.6 1.3 9.3 2.6 34474 4.1 1.1 8.1 2.3 47 94
250 RPM
M3/Hr L/Sec. 58.6 16.3 52.3 14.5 46.3 12.9 40.7 11.3 35.5 9.9 30.6 8.5 26.1 7.2 21.9 6.1 18.1 5.0 14.7 4.1 13.1 3.6 11.6 3.2 10.2 2.8 117
GPM 309.8 276.4 244.8 215.2 187.4 161.6 137.7 115.7 95.6 77.5 69.1 61.2 53.8 188
300 RPM
M3/Hr 70.4 62.8 55.6 48.9 42.6 36.7 31.3 26.3 21.7 17.6 15.7 13.9 12.2
350 RPM
BPD 12393 11055 9792 8607 7497 6465 5508 4629 3825 3099 2764 2448 2152
GPM 361.4 322.4 285.6 251.0 218.7 188.5 160.6 135.0 111.6 90.4 80.6 71.4 62.8 219
350 RPM
400 RPM
BPD
GPM
12634 11191 9836 8568 7388 6295 5290 4372 3541 3159 2798 2459
368.5 326.4 286.9 249.9 215.5 183.6 154.3 127.5 103.3 92.1 81.6 71.7 250
400 RPM
L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. 19.5 82.1 22.8 17.4 73.2 20.3 83.7 23.2 15.4 64.9 18.0 74.1 20.6 13.6 57.0 15.8 65.1 18.1 11.8 49.7 13.8 56.8 15.8 10.2 42.8 11.9 48.9 13.6 8.7 36.5 10.1 41.7 11.6 7.3 30.7 8.5 35.0 9.7 6.0 25.3 7.0 29.0 8.0 4.9 20.5 5.7 23.5 6.5 4.4 18.3 5.1 20.9 5.8 3.9 16.2 4.5 18.5 5.1 3.4 14.3 4.0 16.3 4.5 140 163 187
Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. For Operations below 200 RPM, an auxiliary lubrication system is required. Not all plunger sizes are shown. Contact National-Oilwell for additional information. Spherical Valves must be installed when the pump is fitted with 4.0” (102mm) plungers. Contact Factory for flow rates not listed above. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
267Q-6 Quintuplex Plunger Pump Specifications
FACE OF SUCTION & DISCHARGE
CLPUMP
32 7/8
24 1/2
19 5/8
CLCRANK
66 3/8
19 5/8
24 1/2
32 7/8
33 1/2
56" TO REMOVE CRANKSHAFT (EITHER SIDE)
7 1/4 1" DIA. HOLE THRU 6 PLACES AS SHOWN 1" x 3/8" KEYWAY 4.495
DIA
4.495
B
28 1/2
D
CENTERLINE DISCHARGE
10 5/8
14
24 5/8 C
9" TO REMOVE CONNECTING RODS AND CROSSHEADS
A
14 1/4
CENTERLINE SUCTION
Pump Size maximum plunger size x stroke length, in.(mm): 4 1/4 x 6 (107.0 x 152.4) Rated bhp at 360 rpm (kw): 267 (199.04) Rated plunger load, pounds(Kg): 10,000(4536) Maximum discharge pressure: psi (kPa) “L” model: 1420 (9791) “M” model: 3180 (21,925) Crankshaft extension: in.(mm) Diameter: 4.495 (114.17) Length: 7 1/4 (173.0) Keyway (width x depth): 1 x 3/8 (25.4 x 9.53) Maximum recommended sheave in.(mm): 58 (1473) Minimum recommended sheave in.(mm): 36 (914) For larger sizes: Contact Customer Service Pinion shaft extension, if gear reducer is supplied, in.(mm) For belt or chain drive: Contact Customer Servicey For direct drive: Diameter: 3.375 (85.73) Length: 4 1/2 (114.3) Keyway (width x depth): 7/8 x 7/16 (22.2 x 11.1) Accessory gear reduction unit: 2.698:1, 3.680:1, 5.50:1, 7.316:1, 9.50:1 Oil Capacity, gallons (L) Crankcase: 32 (121.3) Gear Reducer-varies with ratio: 5 1/4 to 7 1/2 (18.7 to 26.7) Weight, pump only on wood shipping skids, pounds (Kg): 6340 (2875.77) Gear unit, approximate pounds (Kg): 2219 (1006.52)
14 5/8
51
73 7/16
Pump Model 267Q-6L 267Q-6M
Flange Connections Discharge Connection Sizes Suction Connection Sizes 4” ANSI-600# L.R. 6” ANSI-300# F.F. 3” ANSI-1500# L.R. 4” ANSI-300# F.F.
Dimensions in inches (mm) A B C D 4 1/2 22 7/8 1 3/4 29 3/4 5 5/8 22 3/8 28 7/8
267Q-6 Quintuplex Plunger Pump Performance Data PUMP
267Q-6L
267Q-6M
PUMP
267Q-6L
267Q-6M
English Units Plunger Plunger BPD Dia. Area per In. Sq. In. RPM 4.250 14.1862 63.1669 4.125 13.3640 59.5059 4.000 12.5664 55.9541 3.875 11.7932 52.5116 3.750 11.0447 49.1784 3.625 10.3206 45.9545 3.500 9.6211 42.8398 3.375 8.9462 39.8345 3.250 8.2958 36.9384 3.125 7.6699 34.1517 3.000 7.0686 31.4742 3.000 7.0686 31.4742 2.875 6.4918 28.9060 2.750 5.9396 26.4470 2.625 5.4119 24.0974 2.500 4.9087 21.8571 2.375 4.4301 19.7260 2.250 3.9761 17.7042 2.125 3.5466 15.7917 2.000 3.1416 13.9885 Brake Horsepower Required
GPM per RPM 1.8424 1.7356 1.6320 1.5316 1.4344 1.3403 1.2495 1.1618 1.0774 0.9961 0.9180 0.9180 0.8431 0.7714 0.7028 0.6375 0.5753 0.5164 0.4606 0.4080
Metric Units Plunger Plunger Dia. Area mm cm2 108 91.524 105 86.219 102 81.073 98 76.085 95 71.256 92 66.584 89 62.072 86 57.717 83 53.521 79 49.483 76 45.604 76 45.604 73 41.883 70 38.320 67 34.915 64 31.669 60 28.581 57 25.652 54 22.881 51 20.268 Kilowatts Required
L/Sec. per RPM 0.1162 0.1095 0.1030 0.0966 0.0905 0.0846 0.0788 0.0733 0.0680 0.0628 0.0579 0.0579 0.0532 0.0487 0.0443 0.0402 0.1307 3.5603 1.7410 0.0257
M3/Hr per RPM 0.4184 0.3942 0.3706 0.3478 0.3257 0.3044 0.2838 0.2639 0.2447 0.2262 0.2085 0.2085 0.1915 0.1752 0.1596 0.1448 3.9669 1.9519 0.2089 0.0927
100 RPM Max. Press. PSI 705 748 796 848 905 969 1039 1118 1205 1304 1420 1420 1540 1684 1848 2037 2257 2515 2820 3180
BPD 6317 5951 5596 5252 4918 4596 4284 3984 3694 3416 3148 3148 2891 2645 2410 2186 1973 1771 1580 1399
GPM 184.2 173.6 163.2 153.2 143.4 134.0 124.9 116.2 107.7 99.6 91.8 91.8 84.3 77.1 70.3 63.7 57.5 51.6 46.1 40.8 84
150 RPM
BPD 9476 8926 8394 7877 7377 6894 6426 5976 5541 5123 4722 4722 4336 3968 3615 3279 2959 2656 2369 2099
GPM 276.4 260.3 244.8 229.7 215.2 201.1 187.4 174.3 161.6 149.4 137.7 137.7 126.5 115.7 105.4 95.6 86.3 77.5 69.1 61.2 126
100 RPM 150 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 4860 41.8 11.6 62.8 17.4 5159 39.4 10.9 59.1 16.4 5487 37.1 10.3 55.6 15.4 5846 34.8 9.7 52.2 14.5 6243 32.6 9.0 48.9 13.6 6681 30.4 8.5 45.7 12.7 7166 28.4 7.9 42.6 11.8 7707 26.4 7.3 39.6 11.0 8311 24.5 6.8 36.7 10.2 8989 22.6 6.3 33.9 9.4 9791 20.8 5.8 31.3 8.7 9791 20.8 5.8 31.3 8.7 10621 19.1 5.3 28.7 8.0 11608 17.5 4.9 26.3 7.3 12740 16.0 4.4 23.9 6.7 14046 14.5 4.0 21.7 6.0 8532 396.7 13.1 595.0 19.6 1141 195.2 356.0 292.8 534.0 0 20.9 174.1 31.3 261.2 21925 9.3 2.6 13.9 3.9 63 94
200 RPM
BPD GPM 12634 368.5 11902 347.1 11191 326.4 10503 306.3 9836 286.9 9191 268.1 8568 249.9 7967 232.4 7388 215.5 6831 199.2 6295 183.6 6295 183.6 5782 168.6 5290 154.3 4820 140.6 4372 127.5 3946 115.1 3541 103.3 3159 92.1 2798 81.6 168
200 RPM
M3/Hr 83.7 78.8 74.1 69.6 65.1 60.9 56.8 52.8 48.9 45.2 41.7 41.7 38.3 35.0 31.9 29.0 793.4 390.4 41.8 18.5
L/Sec. 23.2 21.9 20.6 19.3 18.1 16.9 15.8 14.7 13.6 12.6 11.6 11.6 10.6 9.7 8.9 8.0 26.1 712.1 348.2 5.1 126
250 RPM
BPD 15792 14877 13989 13128 12295 11489 10710 9959 9235 8538 7869 7869 7227 6612 6025 5465 4932 4427 3948 3498
GPM 460.6 433.9 408.0 382.9 358.6 335.1 312.4 290.5 269.3 249.0 229.5 229.5 210.8 192.8 175.7 159.4 143.8 129.1 115.1 102.0 210
250 RPM
300 RPM
BPD 18951 17852 16787 15754 14754 13787 12852 11951 11082 10246 9443 9443 8672 7935 7230 6558 5918 5312 4738 4197
GPM 552.7 520.7 489.6 459.5 430.3 402.1 374.8 348.6 323.2 298.8 275.4 275.4 252.9 231.4 210.9 191.2 172.6 154.9 138.2 122.4 250
300 RPM
320 RPM
BPD 20214 19042 17906 16804 15738 14706 13709 12748 11821 10929 10072 10072 9250 8464 7712 6995 6313 5666 5054 4477
GPM 589.6 555.4 522.2 490.1 459.0 428.9 399.8 371.8 344.8 318.7 293.8 293.8 269.8 246.8 224.9 204.0 184.1 165.2 147.4 130.6 267
360 RPM Max. Press. PSI 625.0 660.0 705.0 750.0 800.0 850.0 920.0 980.0 1060.0 1150.0 1250.0 1250.0 1360.0 1480.0 1630.0 1800.0 1980.0 2220.0 2480.0 2800.0
320 RPM
Max. Press. M3/Hr L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. kPa 104.6 29.1 125.5 34.9 133.9 37.2 4309 98.5 27.4 118.2 32.8 126.1 35.0 4551 92.7 25.7 111.2 30.9 118.6 32.9 4861 87.0 24.2 104.3 29.0 111.3 30.9 5171 81.4 22.6 97.7 27.1 104.2 29.0 5516 76.1 21.1 91.3 25.4 97.4 27.1 5861 70.9 19.7 85.1 23.6 90.8 25.2 6343 66.0 18.3 79.2 22.0 84.4 23.5 6757 61.2 17.0 73.4 20.4 78.3 21.8 7308 56.6 15.7 67.9 18.9 72.4 20.1 7929 52.1 14.5 62.5 17.4 66.7 18.5 8618 52.1 14.5 62.5 17.4 66.7 18.5 8618 47.9 13.3 57.4 16.0 61.3 17.0 9377 43.8 12.2 52.6 14.6 56.1 15.6 10204 39.9 11.1 47.9 13.3 51.1 14.2 11238 36.2 10.1 43.4 12.1 46.3 12.9 12411 991.7 32.7 1190.1 39.2 1269.4 41.8 13652 488.0 890.1 585.6 1068.1 624.6 1139.3 15306 52.2 435.3 62.7 522.3 66.9 557.1 17099 23.2 6.4 27.8 7.7 29.7 8.2 19305 157 186 199
BPD 22741 21423 20144 18905 17705 16544 15423 14341 13298 12295 11331 11331 10407 9521 8676 7869 7102 6374 5686 5036
GPM 663.3 624.8 587.5 551.4 516.4 482.5 449.8 418.3 387.9 358.6 330.5 330.5 303.5 277.7 253.0 229.5 207.1 185.9 165.8 146.9 267
360 RPM
M3/Hr L/Sec. 150.6 41.8 141.9 39.4 133.4 37.1 125.2 34.8 117.3 32.6 109.6 30.4 102.2 28.4 95.0 26.4 88.1 24.5 81.4 22.6 75.1 20.8 75.1 20.8 68.9 19.1 63.1 17.5 57.5 16.0 52.1 14.5 47.0 13.1 42.2 11.7 37.7 10.5 33.4 9.3 199
Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. Not all plunger sizes are shown. Contact National-Oilwell for additional information. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
300Q-5 Quintuplex Plunger Pump 18 5/16;
Specifications 3.500
4.875
DIA.
3.499
DIA.
1/4;9
4.873
11/16; 11
11/16; 5
7/8" x 7/16" KEYWAY
SUCTION AND DISCHARGE
1 1/4" x 5/8" KEYWAY
CONNECTIONS MAY BE
5/8;5
1/2;7
15
"C"
41 1/4;
70 1/2;
15
1/2;7
20 5/8;
38 1/8;
MADE AT EITHER END
1 3/8" DIA. HOLE THRU 4 PLACES, AS SHOWN 1 1/4" x 5/8" KEYWAY 4.875
DIA.
4.873
SHAFT EXTENSION FOR DIRECT DRIVE
"D" 16 3/4;
36 1/2;
"A"
CENTERLINE
2 1/4;
DISCHARGE
10 1/2;
13 1/4;
"F"
6
1/2;6
32 1/4;
1 1/2 " STD. PIPE TAP CRADLE DRAIN, BOTH SIDES
CENTERLINE "B"
SUCTION
1" STD. PIPE TAP
1 1/2 " STD. PIPE TAP
7 3/4;
POWER END OIL DRAIN
MUD TRAP DRAIN
Pump Size maximum plunger size x stroke length, in.(mm): 4 x 5 (102 x 127) Rated bhp at 400 rpm (kw): 300 (224) Rated plunger load, pounds(Kg): 10,700(4853.5) Maximum discharge pressure: psi(kPa) “L” model: 1650 (11,375) “M” model: 3000 (20,682) “H” model: 5000 (34,470) Crankshaft extension: in.(mm) Diameter: 4.875 (123.8) Length long side: 11 11/16 (297) Length short side: 5 5/8 (143) Keyway (width x depth): 1 1/4 x 5/8 (32 x 16) Maximum recommended sheave in.(mm): 58 (1473) Minimum recommended sheave in.(mm): 36 (914) For larger sizes: Contact Customer Service Pinion shaft extension, if gear reducer is supplied, in.(mm) For belt or chain drive: Contact Customer Service For direct drive: Diameter: 3.5 (88.9) Length: 5 11/16 (145) Keyway (width x depth): 7/8 x 7/16 ((22.2 x 11.1) Accessory gear reduction unit: 2.27:1, 2.89:1, 3.25:1, 3.36:1, 3.69:1, 4.38:1, 4.84:1, 5.63:1 Oil Capacity, gallons (L) Crankcase: 12 (45.5) Gear Reducer-varies with ratio: 3.5 to 6.5 (13.2 to 24.6) Weight, pump only on wood shipping skids, pounds (Kg) “L”: 7000 (3175) “M”: 6750 (3062) “H”: 6840 (3103) Gear reducer, approximate, pounds (Kg): 1100 (499)
2" STD. PIPE TAP CRADLE DRAIN
19 3/4; 4 1/2;
40 3/4; "E"
Pump Model 300Q-5L 300Q-5M 300Q-5H
Flange Connections Discharge Connection Sizes Suction Connection Sizes 4 (101.6) API 2000 RJ 8 (203.2) ANSI 150 FF 3 (76.2) NSD 5000 RJ 6 (152.4) NSD 600 RJ 2 (50.8) ANSI 2500 RJ 6 (152.4) NSD 600 RJ
A 6 1/4 4 1/2 4 1/2
Dimensions in inches (mm) B C D E 9 1/8 43 1/4 49 68 6 1/2 41 1/2 48 5/8 65 6 1/2 41 1/2 48 5/8 65 1/8
F 25 1/8 25 7/16 25 5/8
300Q-5 Quintuplex Plunger Pump Performance Data PUMP
300Q-5L
300Q-5M
300Q-5H
PUMP
300Q-5L
300Q-5M
300Q-5H
English Units Plunger Plunger BPD Dia. Area per In. Sq. In. RPM 4.000 12.5664 46.6284 3.750 11.0447 40.9820 3.500 9.6211 35.6999 3.250 8.2958 30.7820 3.000 7.0686 26.2285 2.750 5.9396 22.0392 2.750 5.9396 22.0392 2.500 4.9087 18.2142 2.375 4.4301 16.4383 2.250 3.9761 14.7535 2.125 3.5466 13.1598 2.000 3.1416 11.6571 2.000 3.1416 11.6571 1.875 2.7612 10.2455 1.750 2.4053 8.9250 1.625 2.0739 7.6955 1.500 1.7671 6.5571 Brake Horsepower Required
GPM per RPM 1.3600 1.1953 1.0412 0.8978 0.7650 0.6428 0.6428 0.5312 0.4795 0.4303 0.3838 0.3400 0.3400 0.2988 0.2603 0.2245 0.1912
Metric Units Plunger Plunger Dia. Area mm cm2 102 81.073 95 71.256 89 62.072 83 53.521 76 45.604 70 38.320 70 38.320 64 31.669 60 28.581 57 25.652 54 22.881 51 20.268 51 20.268 48 17.814 44 15.518 41 13.380 38 11.401 Kilowatts Required
L/Sec. per RPM 0.0858 0.0754 0.0657 0.0566 0.0483 0.0406 0.0406 0.0335 0.0302 0.0271 0.0242 0.0215 0.0215 0.0189 0.0164 0.0142 0.0121
M3/Hr per RPM 0.3089 0.2715 0.2365 0.2039 0.1737 0.1460 0.1460 0.1206 0.1089 0.0977 0.0872 0.0772 0.0772 0.0679 0.0591 0.0510 0.0434
100 RPM Max. Press. PSI 851 969 1112 1290 1514 1650 1801 2180 2415 2691 3000 3000 3406 3875 4449 5000 5000
BPD 4663 4099 3570 3079 2623 2204 2204 1822 1644 1476 1316 1166 1166 1025 893 770 656
GPM 136.0 119.5 104.1 89.8 76.5 64.3 64.3 53.1 47.9 43.0 38.4 34.0 34.0 29.9 26.0 22.4 19.1 76
200 RPM
BPD 9326 8197 7140 6157 5246 4408 4408 3643 3288 2951 2632 2332 2332 2050 1785 1540 1312
250 RPM
GPM 272.0 239.1 208.2 179.6 153.0 128.6 128.6 106.2 95.9 86.1 76.8 68.0 68.0 59.8 52.1 44.9 38.2 151
BPD 11658 10246 8925 7696 6558 5510 5510 4554 4110 3689 3290 2915 2915 2562 2232 1924 1640
100 RPM 200 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 5871 30.9 8.6 61.8 17.2 6680 27.1 7.5 54.3 15.1 7668 23.6 6.6 47.3 13.1 8893 20.4 5.7 40.8 11.3 10437 17.4 4.8 34.7 9.7 11376 14.6 4.1 29.2 8.1 12421 14.6 4.1 29.2 8.1 15029 12.1 3.4 24.1 6.7 16653 10.9 3.0 21.8 6.0 18555 9.8 2.7 19.5 5.4 20684 8.7 2.4 17.4 4.8 20684 7.7 2.1 15.4 4.3 23483 7.7 2.1 15.4 4.3 26719 6.8 1.9 13.6 3.8 30672 5.9 1.6 11.8 3.3 34474 5.1 1.4 10.2 2.8 34474 4.3 1.2 8.7 2.4 57 113
GPM 340.0 298.8 260.3 224.5 191.2 160.7 160.7 132.8 119.9 107.6 96.0 85.0 85.0 74.7 65.1 56.1 47.8 188
250 RPM
M3/Hr 77.2 67.9 59.1 51.0 43.4 36.5 36.5 30.2 27.2 24.4 21.8 19.3 19.3 17.0 14.8 12.7 10.9
L/Sec. 21.5 18.9 16.4 14.2 12.1 10.1 10.1 8.4 7.6 6.8 6.1 5.4 5.4 4.7 4.1 3.5 3.0 140
300 RPM
BPD 13989 12295 10710 9235 7869 6612 6612 5465 4932 4427 3948 3498 3498 3074 2678 2309 1968
GPM 408.0 358.6 312.4 269.3 229.5 192.8 192.8 159.4 143.8 129.1 115.1 102.0 102.0 89.6 78.1 67.3 57.4 225
300 RPM
M3/Hr 92.7 81.4 70.9 61.2 52.1 43.8 43.8 36.2 32.7 29.3 26.2 23.2 23.2 20.4 17.7 15.3 13.0
350 RPM
400 RPM
BPD GPM 16320 476.0 14344 418.4 12495 364.4 10774 314.2 9180 267.7 7714 225.0 7714 225.0 6375 185.9 5754 167.8 5164 150.6 4606 134.3 4080 119.0 4080 119.0 3586 104.6 3124 91.1 2694 78.6 2295 66.9 263
BPD GPM 18652 544.0 16393 478.1 14280 416.5 12313 359.1 10492 306.0 8816 257.1 8816 257.1 7286 212.5 6576 191.8 5902 172.1 5264 153.5 4663 136.0 4663 136.0 4099 119.5 3570 104.1 3079 89.8 2623 76.5 300
350 RPM
400 RPM
L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. 25.7 108.1 30.0 123.5 34.3 22.6 95.0 26.4 108.6 30.2 19.7 82.8 23.0 94.6 26.3 17.0 71.4 19.8 81.6 22.7 14.5 60.8 16.9 69.5 19.3 12.2 51.1 14.2 58.4 16.2 12.2 51.1 14.2 58.4 16.2 10.1 42.2 11.7 48.3 13.4 9.1 38.1 10.6 43.6 12.1 8.1 34.2 9.5 39.1 10.9 7.3 30.5 8.5 34.9 9.7 6.4 27.0 7.5 30.9 8.6 6.4 27.0 7.5 30.9 8.6 5.7 23.8 6.6 27.1 7.5 4.9 20.7 5.7 23.6 6.6 4.2 17.8 5.0 20.4 5.7 3.6 15.2 4.2 17.4 4.8 168 196 224
Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. For Operations below 200 RPM, an auxiliary lubrication system is required. Not all plunger sizes are shown. Contact National-Oilwell for additional information. Spherical Valves must be installed when the pump is fitted with 4.0” (102mm) plungers. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
308T-7 Triplex Plunger Pump INTERNAL LUBE PUMP
Specifications
PRESSURE GAUGE
24.00
13.00 TYP
D SUCTION
C DISCHARGE 13.00 TYP
32.00
ÿ 1.12 TYP 4 PLACES
ÿ
1.250 x .625 KEY WAY 10.125 LONG
5.500 5.499
DISCHARGE CONNECTION ROTATION DIRECTION
G 1.50
A
29.25
B
13.75
H
6.50
Pump Size: maximum plunger size x stroke length, in.(mm) 5.750 x 7.125 (146.05 x 180.98) Rated BPH (kW) at 265 RPM: 308 (230) Rated plunger load, pounds (kg): 19400(8800) Maximum discharge pressure: psi (kPa) “XL” model: 1220 (8410) “L” model: 2169 (14952) “M” model: 3600 (24821) “H” model: 8000 (55158) Crankshaft extension: Diameter, in.(mm): 5.500 (139.7) Length, in.(mm): 12.125 (307.98) Keyway width x depth, in.(mm): 1-1/4 x 5/8 (31.75 x 15.875) Maximum recommended sheave diameter, in.(mm): 71 (1803.4) For larger sizes: Contact Customer Service Accessory gear reduction unit: N/A Oil Capacity, gallons (L) Crankcase: 19 (71.92) Weight, pump only on wood shipping skids, pounds (kg): 6013 (2727) Weight varies with pump model Standard Materials for Fluid Ends: “XL” model Cast Duplex Stainless Steel Cast Carbon Steel “L” model Cast Duplex Stainless Steel Cast Nickel-Aluminum-Bronze Billet/Forged Carbon Steel “M” model Cast Duplex Stainless Steel Cast Nickel-Aluminum-Bronze Forged/Plate Carbon Steel “H” model Forged Stainless Steel
SUCTION CONNECTION
15.06
38.01
E
F
Pump Model 308T-7XL 308T-7L 308T-7M 308T-7H
Flange Connections Discharge Connection Sizes Suction Connection Sizes 4 (101.6)-600# ANSI FF 10 (254.0)-150# ANSI FF 4 (101.6)-900# ANSI FF 6 (152.4)-150# ANSI FF 2.5 (63.5)-1500# ANSI FF 4 (101.6)-300# ANSI FF 2 (50.8)-2500# ANSI RTJ 4 (101.6)-300# ANSI RF
A 10 8 1/4 6 7/8 3 7/16
B 14 3/8 14 3/8 8 3/4 12 7/16
Dimensions (Inches) C D E F 34 36 48 3/8 72 33 33 46 3/4 71 34 36 48 3/8 71 31 33 53 5/16 68 3/8
G 16 5/8 13 1/4 16 5/8 11 1/2
H 7 1/4 1 -1 1/2 2 1/4
308T-7 Triplex Plunger Pump Performance Data PUMP
308T-7XL (HP360XL)
308T-7L (HP360AL)
308T-7M (HP360AM)
308T-7H (HP360H)
PUMP
308T-7XL (HP360XL)
308T-7L (HP360AL)
308T-7M (HP360AM)
308T-7H (HP360H)
English Units Plunger Plunger BPD Dia. Area per In. Sq. In. RPM 5.750 25.9672 82.3820 5.500 23.7583 75.3741 5.250 21.6475 68.6776 5.000 19.6349 62.2926 4.750 17.7205 56.2191 4.500 15.9043 50.4570 4.250 14.1862 45.0064 4.125 13.3640 42.3979 4.000 12.5664 39.8673 3.875 11.7932 37.4145 3.750 11.0447 35.0396 3.625 10.3206 32.7426 3.500 9.6211 30.5234 3.375 8.9462 28.3821 3.250 8.2958 26.3186 3.125 7.6699 24.3331 3.000 7.0686 22.4253 2.875 6.4918 20.5955 2.750 5.9396 18.8435 2.500 4.9087 15.5732 2.250 3.9761 12.6143 2.125 3.5466 11.2516 2.000 3.1416 9.9668 1.875 2.7612 8.7599 1.750 2.4053 7.6308 Brake Horsepower Required
GPM per RPM 2.4028 2.1984 2.0031 1.8169 1.6397 1.4717 1.3127 1.2366 1.1628 1.0913 1.0220 0.9550 0.8903 0.8278 0.7676 0.7097 0.6541 0.6007 0.5496 0.4542 0.3679 0.3282 0.2907 0.2555 0.2226
Max. Press. PSI 747 817 896 988 1095 1220 1368 1452 1544 1645 1757 1880 2016 2169 2339 2529 2745 2988 3266 3600 3600 5470 6175 7026 8000
Metric Units Plunger Plunger Dia. Area mm cm2 146 167.530 140 153.279 133 139.661 127 126.677 121 114.326 114 102.608 108 91.524 105 86.219 102 81.073 98 76.085 95 71.256 92 66.584 89 62.072 86 57.717 83 53.521 79 49.483 76 45.604 73 41.883 70 38.320 64 31.669 57 25.652 54 22.881 51 20.268 48 17.814 44 15.518 Kilowatts Required
L/Sec. per RPM 0.1516 0.1387 0.1264 0.1146 0.1035 0.0928 0.0828 0.0780 0.0734 0.0688 0.0645 0.0603 0.0562 0.0522 0.0484 0.0448 0.0413 0.0379 0.0347 0.0287 0.0232 0.0207 0.0183 0.0161 0.0140
100 * RPM 133 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 5151 54.6 15.2 72.6 20.2 5630 49.9 13.9 66.4 18.4 6179 45.5 12.6 60.5 16.8 6812 41.3 11.5 54.9 15.2 7548 37.2 10.3 49.5 13.8 8410 33.4 9.3 44.5 12.3 9429 29.8 8.3 39.6 11.0 10009 28.1 7.8 37.4 10.4 10644 26.4 7.3 35.1 9.8 11342 24.8 6.9 33.0 9.2 12111 23.2 6.4 30.9 8.6 12960 21.7 6.0 28.8 8.0 13903 20.2 5.6 26.9 7.5 14952 18.8 5.2 25.0 6.9 16124 17.4 4.8 23.2 6.4 17439 16.1 4.5 21.4 6.0 18923 14.9 4.1 19.8 5.5 20604 13.6 3.8 18.1 5.0 22520 12.5 3.5 16.6 4.6 24821 10.3 2.9 13.7 3.8 24821 8.4 2.3 11.1 3.1 37715 7.5 2.1 9.9 2.8 42577 6.6 1.8 8.8 2.4 48443 5.8 1.6 7.7 2.1 55158 5.1 1.4 6.7 1.9 87 116
M3/Hr per RPM 0.5457 0.4993 0.4549 0.4126 0.3724 0.3342 0.2981 0.2808 0.2641 0.2478 0.2321 0.2169 0.2022 0.1880 0.1743 0.1612 0.1485 0.1364 0.1248 0.1032 0.0836 0.0745 0.0660 0.0580 0.0505
100 * RPM
BPD 8239 7538 6868 6230 5622 5046 4501 4240 3987 3742 3504 3275 3053 2839 2632 2434 2243 2060 1885 1558 1262 1126 997 876 764
GPM 240.3 219.8 200.3 181.7 164.0 147.2 131.3 123.7 116.3 109.1 102.2 95.5 89.0 82.8 76.8 71.0 65.4 60.1 55.0 45.4 36.8 32.8 29.1 25.5 22.3 117
133 RPM
BPD 10957 10025 9135 8285 7478 6711 5986 5639 5303 4977 4661 4355 4060 3775 3501 3237 2983 2740 2507 2072 1678 1497 1326 1166 1665
GPM 319.6 292.4 266.4 241.6 218.1 195.7 174.6 164.5 154.7 145.1 135.9 127.0 118.4 110.1 102.1 94.4 87.0 79.9 73.1 60.4 48.9 43.6 38.7 34.0 29.6 155
166 RPM
BPD 13676 12513 11401 10341 9333 8376 7472 7039 6618 6211 5817 5436 5067 4712 4369 4040 3723 3419 3129 2586 2094 1868 1655 1455 1267
GPM 398.9 364.9 332.5 301.6 272.2 244.3 217.9 205.3 193.0 181.1 169.7 158.5 147.8 137.4 127.4 117.8 108.6 99.7 91.2 75.4 61.1 54.5 48.3 42.4 36.9 194
166 RPM
M3/Hr L/Sec. 90.6 25.2 82.9 23.0 75.5 21.0 68.5 19.0 61.8 17.2 55.5 15.4 49.5 13.7 46.6 13.0 43.8 12.2 41.1 11.4 38.5 10.7 36.0 10.0 33.6 9.3 31.2 8.7 28.9 8.0 26.8 7.4 24.7 6.9 22.6 6.3 20.7 5.8 17.1 4.8 13.9 3.9 12.4 3.4 11.0 3.0 9.6 2.7 8.4 2.3 145
199 RPM
BPD 16395 15000 13667 12397 11188 10041 8957 8438 7934 7446 6973 6516 6075 5649 5238 4843 4463 4099 3750 3100 2511 2240 1984 1744 1519
GPM 478.2 437.5 398.6 361.6 326.3 292.9 261.2 246.1 231.4 217.2 203.4 190.0 177.2 164.7 152.8 141.2 130.2 119.5 109.4 90.4 73.2 65.3 57.8 50.8 44.3 232
199 RPM
M3/Hr 108.6 99.4 90.5 82.1 74.1 66.5 59.3 55.9 52.6 49.3 46.2 43.2 40.2 37.4 34.7 32.1 29.6 27.1 24.8 20.5 16.6 14.8 13.1 11.5 10.1
232 RPM
BPD 19113 17487 15934 14452 13043 11707 10442 9837 9250 8681 8130 7597 7082 6585 6106 5646 5203 4779 4372 3613 2927 2611 2313 2033 1771
GPM 557.5 510.0 464.7 421.5 380.4 341.4 304.5 286.9 269.8 253.2 237.1 221.6 206.5 192.1 178.1 164.7 151.7 139.4 127.5 105.4 85.4 76.1 67.4 59.3 51.6 270
232 RPM
265 RPM
BPD GPM 21832 636.7 19975 582.6 18200 530.8 16508 481.5 14899 434.5 13372 390.0 11927 347.9 11236 327.7 10565 308.1 9915 289.2 9286 270.8 8677 253.1 8089 235.9 7522 219.4 6975 203.4 6449 188.1 5943 173.3 5458 159.2 4994 145.6 4127 120.4 3343 97.5 2982 87.0 2642 77.0 2322 67.7 2023 59.0 308
265 RPM
L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. 30.2 126.6 35.2 144.6 40.2 27.6 115.8 32.2 132.3 36.8 25.1 105.5 29.3 120.5 33.5 22.8 95.7 26.6 109.3 30.4 20.6 86.4 24.0 98.7 27.4 18.5 77.5 21.5 88.6 24.6 16.5 69.2 19.2 79.0 21.9 15.5 65.2 18.1 74.4 20.7 14.6 61.3 17.0 70.0 19.4 13.7 57.5 16.0 65.7 18.2 12.8 53.8 15.0 61.5 17.1 12.0 50.3 14.0 57.5 16.0 11.2 46.9 13.0 53.6 14.9 10.4 43.6 12.1 49.8 13.8 9.6 40.4 11.2 46.2 12.8 8.9 37.4 10.4 42.7 11.9 8.2 34.5 9.6 39.4 10.9 7.5 31.6 8.8 36.2 10.0 6.9 29.0 8.0 33.1 9.2 5.7 23.9 6.6 27.3 7.6 4.6 19.4 5.4 22.1 6.2 4.1 17.3 4.8 19.7 5.5 3.6 15.3 4.3 17.5 4.9 3.2 13.5 3.7 15.4 4.3 2.8 11.7 3.3 13.4 3.7 173 201 230
Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. *Operation below 150 RPM requires an “optional” externally-mounted electric motor-driven auxillary lubrication system. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
350Q-5 Quintuplex Plunger Pump EXTERNAL LUBE PUMP
Specifications
ÿ 1.00 TYP 4 PLACES
38.25
C/2
C/2
45.75 TYP D
C
C
D
22.88 TYP D/2
D/2
27.61
ROTATI0N DIRECTION 10.16
1.250 x .625 KEYWAY 9.000 LONG
ÿ
4.937 4.936
350Q-5H ONLY
13.66
G
A
G A
B
12.00
H
1.25
11.75
16.38
H
44.50
E
Pump Size: maximum plunger size x stroke length, in.(mm): 4.000 x 5.000 (101.6 x 127) Rated BHP (kW) at 360 RPM: 350 (261) Rated plunger load, pounds (kg): 13850(6282) Maximum discharge pressure: psi (kPa) “L” model: 1670 (11511) “M” model: 3483 (24017) “H” model: 6000 (41369) Crankshaft extension: Diameter, in.(mm): 4.937 (125.4) Length, in.(mm): 10.125 (257.18) Keyway width x depth, in.(mm): 1 1/4 x 5/8 (31.75 x 15.875) Maximum recommended sheave diameter, in.(mm): 63 (1346.2) For larger sizes: Contact Customer Service Oil Capacity, gallons (L) Crankcase: 25.0 (94.63) Gear Reducer-varies with ratio: N/A Weight, pump only on wood shipping skids, pounds (kg): 9000 (4082) Standard Materials For Fluid End Bodies: “L” & “M” modelS Cast Nickel-Aluminum-Bronze Cast Duplex Stainless Steel Forged/Plate Carbon Steel “H” model Forged Carbon Steel Forged Nickel-Aluminum-Bronze
E
59.38 F
Pump Model 350Q-5L 350Q-5M 350Q-5H
Flange Connections Discharge Connection Sizes Suction Connection Sizes 4 (101.6)-2000# API 8 (203.2)-300# ANSI FF 3 (76.02)-1500# ANSI FF 6 (152.4)-300# ANSI FF 2 (50.8)-2500# ANSI RF 4 (101.6)-300# ANSI RF
F
A 6 1/2 6 10 3/8
B 9 1/2 8 0
Dimensions (Inches) C D E 45 52 53 7/8 45 1/2 51 1/2 53 1/2 52 49 3/4 52
F 77 3/4 76 1/8 80 3/4
G 12 1/2 12 5/8 15
H 5 2 1/4 7
350Q-5 Quintuplex Plunger Pump Performance Data PUMP
350Q-5L (Q350-4)
350Q-5M (Q350-3)
350Q-5H (Q350-2)
PUMP
350Q-5L (Q350-4)
350Q-5M (Q350-3)
350Q-5H (Q350-2)
English Units Plunger Plunger BPD Dia. Area per In. Sq. In. RPM 4.000 12.5664 46.6284 3.875 11.7932 43.7597 3.750 11.0447 40.9820 3.625 10.3206 38.2954 3.500 9.6211 35.6999 3.375 8.9462 33.1954 3.250 8.2958 30.7820 3.250 8.2958 30.7820 3.125 7.6699 28.4597 3.000 7.0686 26.2285 2.875 6.4918 24.0883 2.750 5.9396 22.0392 2.625 5.4119 20.0812 2.500 4.9087 18.2142 2.375 4.4301 16.4383 2.250 3.9761 14.7535 2.250 3.9761 14.7535 2.125 3.5466 13.1598 2.000 3.1416 11.6571 1.875 2.7612 10.2455 1.750 2.4053 8.9250 1.625 2.0739 7.6955 1.500 1.7671 6.5571 Brake Horsepower Required
GPM per RPM 1.3600 1.2763 1.1953 1.1169 1.0412 0.9682 0.8978 0.8978 0.8301 0.7650 0.7026 0.6428 0.5857 0.5312 0.4795 0.4303 0.4303 0.3838 0.3400 0.2988 0.2603 0.2245 0.1912
Metric Units Plunger Plunger Dia. Area mm cm2 102 81.073 98 76.085 95 71.256 92 66.584 89 62.072 86 57.717 83 53.521 83 53.521 79 49.483 76 45.604 73 41.883 70 38.320 67 34.915 64 31.669 60 28.581 57 25.652 57 25.652 54 22.881 51 20.268 48 17.814 44 15.518 41 13.380 38 11.401 Kilowatts Required
L/Sec. per RPM 0.0858 0.0805 0.0754 0.0705 0.0657 0.0611 0.0566 0.0566 0.0524 0.0483 0.0443 0.0406 0.0370 0.0335 0.0302 0.0271 0.0271 0.0242 0.0215 0.0189 0.0164 0.0142 0.0121
M3/Hr per RPM 0.3089 0.2899 0.2715 0.2537 0.2365 0.2199 0.2039 0.2039 0.1885 0.1737 0.1596 0.1460 0.1330 0.1206 0.1089 0.0977 0.0977 0.0872 0.0772 0.0679 0.0591 0.0510 0.0434
100 RPM Max. Press. PSI 1102 1174 1254 1342 1440 1548 1670 1670 1806 1959 2133 2332 2559 2822 3126 3483 3483 3905 4409 5016 5758 6000 6000
BPD 4663 4376 4099 3830 3570 3320 3079 3079 2846 2623 2409 2204 2009 1822 1644 1476 1476 1316 1166 1025 893 770 656
GPM 136.0 127.6 119.5 111.7 104.1 96.8 89.8 89.8 83.0 76.5 70.3 64.3 58.6 53.1 47.9 43.0 43.0 38.4 34.0 29.9 26.0 22.4 19.1 98
150 RPM
BPD 6995 6564 6148 5745 5355 4980 4618 4618 4269 3935 3614 3306 3013 2733 2466 2214 2214 1974 1749 1537 1339 1155 984
GPM 204.0 191.4 179.3 167.5 156.2 145.2 134.7 134.7 124.5 114.7 105.4 96.4 87.9 79.7 71.9 64.5 64.5 57.6 51.0 44.8 39.0 33.7 28.7 146
100 RPM 150 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 7599 30.9 8.6 46.3 12.9 8097 29.0 8.1 43.5 12.1 8646 27.1 7.5 40.7 11.3 9253 25.4 7.0 38.0 10.6 9925 23.6 6.6 35.5 9.9 10674 22.0 6.1 33.0 9.2 11511 20.4 5.7 30.6 8.5 11511 20.4 5.7 30.6 8.5 12450 18.9 5.2 28.3 7.9 13510 17.4 4.8 26.1 7.2 14710 16.0 4.4 23.9 6.6 16077 14.6 4.1 21.9 6.1 17645 13.3 3.7 20.0 5.5 19454 12.1 3.4 18.1 5.0 21555 10.9 3.0 16.3 4.5 24017 9.8 2.7 14.7 4.1 24017 9.8 2.7 14.7 4.1 26926 8.7 2.4 13.1 3.6 30396 7.7 2.1 11.6 3.2 34584 6.8 1.9 10.2 2.8 39701 5.9 1.6 8.9 2.5 41369 5.1 1.4 7.6 2.1 41369 4.3 1.2 6.5 1.8 73 109
200 RPM
BPD 9326 8752 8197 7660 7140 6640 6157 6157 5692 5246 4818 4408 4017 3643 3288 2951 2951 2632 2332 2050 1785 1540 1312
GPM 272.0 255.3 239.1 223.4 208.2 193.6 179.6 179.6 166.0 153.0 140.5 128.6 117.1 106.2 95.9 86.1 86.1 76.8 68.0 59.8 52.1 44.9 38.2
250 RPM
BPD 11658 10940 10246 9574 8925 8299 7696 7696 7115 6558 6023 5510 5021 4554 4110 3689 3689 3290 2915 2562 2232 1924 1640
195
200 RPM
M3/Hr 61.8 58.0 54.3 50.7 47.3 44.0 40.8 40.8 37.7 34.7 31.9 29.2 26.6 24.1 21.8 19.5 19.5 17.4 15.4 13.6 11.8 10.2 8.7
L/Sec. 17.2 16.1 15.1 14.1 13.1 12.2 11.3 11.3 10.5 9.7 8.9 8.1 7.4 6.7 6.0 5.4 5.4 4.8 4.3 3.8 3.3 2.8 2.4 145
GPM 340.0 319.1 298.8 279.2 260.3 242.1 224.5 224.5 207.5 191.2 175.6 160.7 146.4 132.8 119.9 107.6 107.6 96.0 85.0 74.7 65.1 56.1 47.8 243
250 RPM
M3/Hr 77.2 72.5 67.9 63.4 59.1 55.0 51.0 51.0 47.1 43.4 39.9 36.5 33.3 30.2 27.2 24.4 24.4 21.8 19.3 17.0 14.8 12.7 10.9
300 RPM
BPD 13989 13128 12295 11489 10710 9959 9235 9235 8538 7869 7227 6612 6025 5465 4932 4427 4427 3948 3498 3074 2678 2309 1968
GPM 408.0 382.9 358.6 335.1 312.4 290.5 269.3 269.3 249.0 229.5 210.8 192.8 175.7 159.4 143.8 129.1 129.1 115.1 102.0 89.6 78.1 67.3 57.4 292
300 RPM
360 RPM
BPD 16787 15754 14754 13787 12852 11951 11082 11082 10246 9443 8672 7935 7230 6558 5918 5312 5312 4738 4197 3689 3213 2771 2361
GPM 489.6 459.5 430.3 402.1 374.8 348.6 323.2 323.2 298.8 275.4 252.9 231.4 210.9 191.2 172.6 154.9 154.9 138.2 122.4 107.6 93.7 80.8 68.8 350
360 RPM
L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. 21.5 92.7 25.7 111.2 30.9 20.1 87.0 24.2 104.3 29.0 18.9 81.4 22.6 97.7 27.1 17.6 76.1 21.1 91.3 25.4 16.4 70.9 19.7 85.1 23.6 15.3 66.0 18.3 79.2 22.0 14.2 61.2 17.0 73.4 20.4 14.2 61.2 17.0 73.4 20.4 13.1 56.6 15.7 67.9 18.9 12.1 52.1 14.5 62.5 17.4 11.1 47.9 13.3 57.4 16.0 10.1 43.8 12.2 52.6 14.6 9.2 39.9 11.1 47.9 13.3 8.4 36.2 10.1 43.4 12.1 7.6 32.7 9.1 39.2 10.9 6.8 29.3 8.1 35.2 9.8 6.8 29.3 8.1 35.2 9.8 6.1 26.2 7.3 31.4 8.7 5.4 23.2 6.4 27.8 7.7 4.7 20.4 5.7 24.4 6.8 4.1 17.7 4.9 21.3 5.9 3.5 15.3 4.2 18.4 5.1 3.0 13.0 3.6 15.6 4.3 181 217 261
Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
430T-7 Triplex Plunger Pump 1 1/2" x 3/4" KEYWAY
5.998 DIA. 6.000
Specifications SUCTION & DISCHARGE CONNECTIONS MAY BE MADE AT EITHER END
10 1/4" (USABLE SHAFT EXT.)
45 7/8
"C"
39 27/32
"C/2"
20 3/4
22 15/16
14 3/8
"C"
79 11/16
14 3/8
20 3/4
8
6 1/2
4 7/8
8 1 1/2 " DIA. HOLE THRU
6.000 DIA. 5.998
4 PLACES, AS SHOWN
10 1/4" (USABLE SHAFT EXT.)
"H" FLUID END ONLY 1 1/2" x 3/4" KEYWAY DISCHARGE CENTERLINE
28 13/16
"A"
2 1/4
"B" 8 1/2
13 5/8
1 1/4
15 1/2
1 1/2 " NPT (1 EACH SIDE)
15 1/8
SUCTION CENTERLINE
Pump Size maximum plunger size x stroke length, in.(mm): 5 x 7 (127 x 178) Rated bhp at 300 rpm (kw): 430 (320) Rated plunger load, pounds(Kg): 24500(6738) Maximum discharge pressure: psi (kPa) “L” model: 1550 (10,687) “M” model: 3150 (21,719) “H” model: 5000 (34,470) Crankshaft extension: in.(mm) Diameter: 6 (152.4) Length long side: 10 1/4 (260.4) Length short side: 10 1/4 (260.4) Keyway (width x depth): 1 1/2 x 3/4 (38.1 x 19.0) Maximum recommended sheave in.(mm): 58 (1473) Minimum recommended sheave in.(mm): 36 (914) For larger sizes: Contact Customer Service Accessory gear reduction unit ratio: N/A Oil Capacity, gallons (L) Crankcase: 22 (83.6) Weight, pump only on wood shipping skids, pounds (Kg): 10,500 (4763)
51 5/8 12 1/2 61 7/8
2" NPT (CRADLE DRAIN)
16 7/8
"D" "E"
1" NPT (POWER END OIL DRAIN)
Pump Model 430T-5L 430T-5M 430T-5H
Flange Connections Discharge Connection Sizes Suction Connection Sizes A 6 (152.4) API 2000 RJ 10 (254) ANSI 150 FF 10 1/4 4 (101.6) ANSI 1500 RJ 6 (152.4) ANSI 300 FF 5 1/4 3 (76.2) ANSI 2500 RJ 6 (152.40) ANSI 300 FF 5 1/4
Dimensions in inches (mm) B C D E 10 3/4 47 3/4 65 3/8 90 1/4 8 3/4 43 64 3/8 87 3/4 8 3/4 40 1/8 64 7/8 100 1/4
430T-7 Triplex Plunger Pump Performance Data PUMP
430T-7L
430T-7M
430T-7H
PUMP
430T-7L
430T-7M
430T-7H
English Units Plunger Plunger BPD Dia. Area per In. Sq. In. RPM 5.000 19.6349 61.1998 4.750 17.7205 55.2328 4.500 15.9043 49.5718 4.250 14.1862 44.2168 4.000 12.5664 39.1679 3.750 11.0447 34.4249 3.500 9.6211 29.9879 3.250 8.2958 25.8569 3.000 7.0686 22.0319 3.000 7.0686 22.0319 2.750 5.9396 18.5129 2.500 4.9087 15.2999 2.375 4.4301 13.8082 Brake Horsepower Required
GPM per RPM 1.7850 1.6110 1.4458 1.2897 1.1424 1.0041 0.8746 0.7542 0.6426 0.6426 0.5400 0.4462 0.4027
Metric Units Plunger Plunger Dia. Area mm cm2 127 126.677 121 114.326 114 102.608 108 91.524 102 81.073 95 71.256 89 62.072 83 53.521 76 45.604 76 45.604 70 38.320 64 31.669 60 28.581 Kilowatts Required
L/Sec. per RPM 0.1126 0.1016 0.0912 0.0814 0.0721 0.0633 0.0552 0.0476 0.0405 0.0405 0.0341 0.0282 0.0254
M3/Hr per RPM 0.4054 0.3658 0.3284 0.2929 0.2594 0.2280 0.1986 0.1713 0.1459 0.1459 0.1226 0.1013 0.0915
100 RPM Max. Press. PSI 1248 1383 1540 1550 1550 2218 2546 2953 3150 3466 4125 4991 5000
BPD 6120 5524 4958 4422 3917 3443 2999 2586 2204 2204 1852 1530 1381
GPM 178.5 161.1 144.6 129.0 114.2 100.4 87.5 75.4 64.3 64.3 54.0 44.6 40.3 145
150 RPM
BPD 9180 8285 7436 6633 5876 5164 4499 3879 3305 3305 2777 2295 2072
200 RPM
GPM 267.7 241.6 216.9 193.4 171.4 150.6 131.2 113.1 96.4 96.4 81.0 66.9 60.4 217
BPD 12240 11047 9915 8844 7834 6885 5998 5172 4407 4407 3703 3060 2762
GPM 357.0 322.2 289.2 257.9 228.5 200.8 174.9 150.8 128.5 128.5 108.0 89.2 80.5
250 RPM
BPD 15300 13809 12393 11055 9792 8607 7497 6465 5508 5508 4629 3825 3453
289
100 RPM 150 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 8603 40.5 11.3 60.8 16.9 9533 36.6 10.2 54.9 15.2 10621 32.8 9.1 49.3 13.7 10687 29.3 8.1 43.9 12.2 10687 25.9 7.2 38.9 10.8 15295 22.8 6.3 34.2 9.5 17557 19.9 5.5 29.8 8.3 20363 17.1 4.8 25.7 7.1 21719 14.6 4.1 21.9 6.1 23898 14.6 4.1 21.9 6.1 28440 12.3 3.4 18.4 5.1 34413 10.1 2.8 15.2 4.2 34474 9.1 2.5 13.7 3.8 108 162
200 RPM
M3/Hr 81.1 73.2 65.7 58.6 51.9 45.6 39.7 34.3 29.2 29.2 24.5 20.3 18.3
L/Sec. 22.5 20.3 18.2 16.3 14.4 12.7 11.0 9.5 8.1 8.1 6.8 5.6 5.1 216
GPM 446.2 402.7 361.5 322.4 285.6 251.0 218.7 188.5 160.6 160.6 135.0 111.6 100.7 361
250 RPM
M3/Hr 101.3 91.5 82.1 73.2 64.9 57.0 49.7 42.8 36.5 36.5 30.7 25.3 22.9
275 RPM
BPD 16830 15190 13633 12160 10772 9467 8247 7111 6059 6059 5092 4208 3798
GPM 490.9 443.0 397.6 354.7 314.2 276.1 240.5 207.4 176.7 176.7 148.5 122.7 110.8 397
275 RPM
300 RPM
BPD GPM 18360 535.5 16570 483.3 14872 433.8 13266 386.9 11751 342.7 10328 301.2 8997 262.4 7758 226.2 6610 192.8 6610 192.8 5554 162.0 4590 133.9 4143 120.8 433
300 RPM
L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. 28.2 111.5 31.0 121.6 33.8 25.4 100.6 27.9 109.8 30.5 22.8 90.3 25.1 98.5 27.4 20.3 80.5 22.4 87.9 24.4 18.0 71.3 19.8 77.8 21.6 15.8 62.7 17.4 68.4 19.0 13.8 54.6 15.2 59.6 16.6 11.9 47.1 13.1 51.4 14.3 10.1 40.1 11.1 43.8 12.2 10.1 40.1 11.1 43.8 12.2 8.5 33.7 9.4 36.8 10.2 7.0 27.9 7.7 30.4 8.4 6.4 25.2 7.0 27.4 7.6 269 296 323
Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. For Operations below 100 RPM, an auxiliary lubrication system is required. Not all plunger sizes are shown. Contact National-Oilwell for additional information. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
543Q-7 Quintuplex Plunger Pump Specifications 24.00 TYP
C DISCHARGE
C
C/2
78.25 D SUCTION
24.00 TYP
D D/2
43.00
ÿ
5.500 5.499
1.250 X .625 KEYWAY 10.125 LONG
543Q-7H ONLY
DISCHARGE CONNECTION
A H 1.50
H
A
29.30 B
B
13.75
G
G 1.25 6.50
26.50 15.06
38.00
E E
SUCTION CONNECTION
F
F
Pump Model 543Q-7XL 543Q-7AL 543Q-7AM 543Q-7H
Flange Connections Discharge Connection Sizes Suction Connection Sizes 4 (101.6)-600# ANSI FF 10 (254.0)-150# ANSI FF 4 (101.6)-900# ANSI FF 8 (203.2)-150# ANSI FF 3 (76.2)-1500# ANSI FF 6 (152.4)-300# ANSI FF 3 (76.2)-2500# ANSI RTJ 6 (152.4)-300# ANSI RF
A 10 8 5/8 6 7/8 4 1/2
SUCTION CONNECTION
Pump Size: maximum plunger size x stroke length, in.(mm): 5.750 x 7.125 (146.05 x 180.975) Rated BHP (kW) at 280 RPM: 543 (405) Rated plunger load, pounds (kg): 19400(8800) Maximum discharge pressure: psi (kPa) “XL” model: 1220 (8410) “L” model: 2169 (14952) “M” model: 3600 (24821) “H” model: 8000 (55158) Crankshaft extension: Diameter, in.(mm): 5.500 (139.7) Length, in.(mm): 12.125 (307.98) Keyway width x depth, in.(mm): 1-1/4 x 5/8 (31.75 x 15.875) Maximum recommended sheave diameter, in.(mm): 71 (1803.4) For larger sizes: Contact Customer Service Oil Capacity, gallons (L) Crankcase: 25 (94.63) Weight, pump only on wood shipping skids, pounds (kg): 8948 (4058.1) Weight varies with pump model Standard Materials for Fluid Ends: “XL” model Cast Duplex Stainless Steel Cast Carbon Steel “L” & “M” model Cast Duplex Stainless Steel Forged/Plate Carbon Steel “H” model Forged 15-5 Stainless Steel
Dimensions (Inches) B C D E F G H 14 3/8 56 58 48 3/8 72 7 1/8 16 9/16 11 7/8 55 55 48 13/16 73 3 3/8 15 9 57 57 46 3/4 71 0 13 3/8 13 11/32 53 1/2 56 48 3/8 69 11/16 4 11/32 13 9/16
543Q-7 Quintuplex Plunger Pump Performance Data PUMP
543Q-7XL (HP600XL)
543Q-7L (HP600AL)
543Q-7M (HP600AM)
543Q-7H (HP600H)
PUMP
543Q-7XL (HP600XL)
543Q-7L (HP600AL)
543Q-7M (HP600AM)
543Q-7H (HP600H)
English Units Plunger Plunger BPD Dia. Area per In. Sq. In. RPM 5.750 25.9672 137.3033 5.500 23.7583 125.6235 5.250 21.6475 114.4627 5.000 19.6349 103.8211 4.750 17.7205 93.6985 4.500 15.9043 84.0951 4.250 14.1862 75.0107 4.125 13.3640 70.6632 4.000 12.5664 66.4455 3.875 11.7932 62.3575 3.750 11.0447 58.3993 3.625 10.3206 54.5709 3.500 9.6211 50.8723 3.375 8.9462 47.3035 3.250 8.2958 43.8644 3.125 7.6699 40.5551 3.000 7.0686 37.3756 2.875 6.4918 34.3258 2.750 5.9396 31.4059 2.500 4.9087 25.9553 2.250 3.9761 21.0238 2.125 3.5466 18.7527 2.000 3.1416 16.6114 1.875 2.7612 14.5998 1.750 2.4053 12.7181 Brake Horsepower Required
GPM per RPM 4.0047 3.6640 3.3385 3.0281 2.7329 2.4528 2.1878 2.0610 1.9380 1.8188 1.7033 1.5917 1.4838 1.3797 1.2794 1.1829 1.0901 1.0012 0.9160 0.7570 0.6132 0.5470 0.4845 0.4258 0.3709
Metric Units Plunger Plunger Dia. Area mm cm2 146 167.530 140 153.279 133 139.661 127 126.677 121 114.326 114 102.608 108 91.524 105 86.219 102 81.073 98 76.085 95 71.256 92 66.584 89 62.072 86 57.717 83 53.521 79 49.483 76 45.604 73 41.883 70 38.320 64 31.669 57 25.652 54 22.881 51 20.268 48 17.814 44 15.518 Kilowatts Required
L/Sec. per RPM 0.2527 0.2312 0.2106 0.1910 0.1724 0.1547 0.1380 0.1300 0.1223 0.1147 0.1075 0.1004 0.0936 0.0870 0.0807 0.0746 0.0688 0.0632 0.0578 0.0478 0.0387 0.0345 0.0306 0.0269 0.0234
M3/Hr per RPM 0.9095 0.8321 0.7582 0.6877 0.6206 0.5570 0.4969 0.4681 0.4401 0.4130 0.3868 0.3615 0.3370 0.3133 0.2905 0.2686 0.2476 0.2274 0.2080 0.1719 0.1393 0.1242 0.1100 0.0967 0.0842
100 * RPM Max. Press. PSI 747 817 896 988 1095 1220 1368 1452 1544 1645 1757 1880 2016 2169 2339 2529 2745 2988 3266 3600 3600 5470 6175 7026 8000
BPD GPM 13731 400.5 12563 366.4 11447 333.8 10383 302.8 9370 273.3 8410 245.3 7502 218.8 7067 206.1 6645 193.8 6236 181.9 5840 170.3 5458 159.2 5088 148.4 4731 138.0 4387 127.9 4056 118.3 3738 109.0 3433 100.1 3141 91.6 2596 75.7 2103 61.3 1876 54.7 1662 48.4 1460 42.6 1272 37.1 194
100 * RPM Max. Press. kPa M3/Hr L/Sec. 5151 90.9 25.3 5630 83.2 23.1 6179 75.8 21.1 6812 68.8 19.1 7548 62.1 17.2 8410 55.7 15.5 9429 49.7 13.8 10009 46.8 13.0 10644 44.0 12.2 11342 41.3 11.5 12111 38.7 10.7 12960 36.1 10.0 13903 33.7 9.4 14952 31.3 8.7 16124 29.1 8.1 17439 26.9 7.5 18923 24.8 6.9 20604 22.7 6.3 22520 20.8 5.8 24821 17.2 4.8 24821 13.9 3.9 37715 12.4 3.5 42577 11.0 3.1 48443 9.7 2.7 55158 8.4 2.3 145
150 RPM
BPD 20596 18844 17170 15574 14055 12615 11252 10600 9967 9354 8760 8186 7631 7096 6580 6084 5607 5149 4711 3894 3154 2813 2492 2190 5214
GPM 600.7 549.6 500.8 454.2 409.9 367.9 328.2 309.2 290.7 272.8 255.5 238.7 222.6 207.0 191.9 177.4 163.5 150.2 137.4 113.6 92.0 82.0 72.7 63.9 55.6 291
150 RPM
M3/Hr L/Sec. 136.4 37.9 124.8 34.7 113.7 31.6 103.2 28.7 93.1 25.9 83.6 23.2 74.5 20.7 70.2 19.5 66.0 18.3 62.0 17.2 58.0 16.1 54.2 15.1 50.5 14.0 47.0 13.1 43.6 12.1 40.3 11.2 37.1 10.3 34.1 9.5 31.2 8.7 25.8 7.2 20.9 5.8 18.6 5.2 16.5 4.6 14.5 4.0 12.6 3.5 217
175 RPM
BPD 24029 21985 20031 18169 16398 14717 13127 12367 11628 10913 10220 9550 8903 8279 7677 7098 6541 6008 5497 4543 3680 3282 2907 2555 2226
GPM 700.8 641.2 584.2 529.9 478.3 429.2 382.9 360.7 339.1 318.3 298.1 278.5 259.7 241.4 223.9 207.0 190.8 175.2 160.3 132.5 107.3 95.7 84.8 74.5 64.9
200 RPM
BPD 27461 25125 22893 20765 18740 16820 15003 14133 13290 12472 11680 10915 10175 9461 8773 8112 7476 6866 6282 5192 4205 3751 3323 2920 2544
340
175 RPM
M3/Hr 159.2 145.6 132.7 120.3 108.6 97.5 86.9 81.9 77.0 72.3 67.7 63.3 59.0 54.8 50.8 47.0 43.3 39.8 36.4 30.1 24.4 21.7 19.3 16.9 14.7
L/Sec. 44.2 40.5 36.9 33.4 30.2 27.1 24.2 22.8 21.4 20.1 18.8 17.6 16.4 15.2 14.1 13.1 12.0 11.1 10.1 8.4 6.8 6.0 5.3 4.7 4.1 254
GPM 800.9 732.8 667.7 605.6 546.6 490.6 437.6 412.2 387.6 363.8 340.7 318.3 296.8 275.9 255.9 236.6 218.0 200.2 183.2 151.4 122.6 109.4 96.9 85.2 74.2 388
200 RPM
M3/Hr 181.9 166.4 151.6 137.5 124.1 111.4 99.4 93.6 88.0 82.6 77.4 72.3 67.4 62.7 58.1 53.7 49.5 45.5 41.6 34.4 27.9 24.8 22.0 19.3 16.8
225 RPM
BPD 30894 28266 25755 23360 21083 18922 16878 15900 14951 14031 13140 12279 11447 10644 9870 9125 8410 7724 7067 5840 4731 4220 3738 3285 2862
GPM 901.1 824.4 751.2 681.3 614.9 551.9 492.3 463.7 436.0 409.2 383.2 358.1 333.8 310.4 287.9 266.1 245.3 225.3 206.1 170.3 138.0 123.1 109.0 95.8 83.5 436
225 RPM
280 RPM
BPD 38445 35175 32050 29070 26236 23547 21003 19786 18605 17461 16352 15280 14245 13245 12283 11356 10466 9612 8794 7268 5887 5251 4652 4088 3562
GPM 1121.3 1025.9 934.8 847.9 765.2 686.8 612.6 577.1 542.6 509.3 476.9 445.7 415.5 386.3 358.2 331.2 305.2 280.3 256.5 212.0 171.7 153.1 135.7 119.2 103.9 543
280 RPM
L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. 50.5 204.6 56.8 254.6 70.7 46.2 187.2 52.0 233.0 64.7 42.1 170.6 47.4 212.3 59.0 38.2 154.7 43.0 192.6 53.5 34.5 139.6 38.8 173.8 48.3 30.9 125.3 34.8 156.0 43.3 27.6 111.8 31.1 139.1 38.6 26.0 105.3 29.3 131.1 36.4 24.5 99.0 27.5 123.2 34.2 22.9 92.9 25.8 115.7 32.1 21.5 87.0 24.2 108.3 30.1 20.1 81.3 22.6 101.2 28.1 18.7 75.8 21.1 94.4 26.2 17.4 70.5 19.6 87.7 24.4 16.1 65.4 18.2 81.4 22.6 14.9 60.4 16.8 75.2 20.9 13.8 55.7 15.5 69.3 19.3 12.6 51.2 14.2 63.7 17.7 11.6 46.8 13.0 58.2 16.2 9.6 38.7 10.7 48.1 13.4 7.7 31.3 8.7 39.0 10.8 6.9 27.9 7.8 34.8 9.7 6.1 24.8 6.9 30.8 8.6 5.4 21.8 6.0 27.1 7.5 4.7 19.0 5.3 23.6 6.6 289 325 405
Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. *Operation below 150 RPM requires an “optional” externally-mounted electric motor-driven auxillary lubrication system. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
622T-8 Triplex Plunger Pump OIL LEVEL GAUGE
Specifications
ÿ1.13 TYP 6 PLACES
27.44
20.00 TYP
C/2 C DISCHARGE D
C D SUCTION 20.00 TYP
23.37
D/2
15.05
ROTATI0N DIRECTION
1.750 x .875 KEYWAY 12.000 LONG 7.000 6.999
ÿ
622T-8L & 622T-8MS
DISCHARGE CONNECTION
G
G A
A 36.16
18.00
B
B
H 1.25 TYP
11.00
10.00 SUCTION CONNECTION 18.75
49.00
E
F
Pump Model 622T-8XL 622T-8L 622T-8MS
E
F
Flange Connections Discharge Connection Sizes Suction Connection Sizes A 6 (152.4)-600# ANSI FF 10 (254)-600# ANSI FF 11 1/2 4 (101.6)-1500# ANSI RF 8 (203.2)-900# ANSI FF 14 1/2 3 (76.2)-2500# ANSI RTJ 6 (152.4)-1500# ANSI RF 7 15/16
B 15 1/4 20 1/4 9 1/2
Pump Size: maximum plunger size x stroke length, in.(mm): 7.000 x 8.000 (177.8 x 203.2) Rated BHP (kW) at 260 RPM: 622 (464) Rated plunger load, pounds (kg): 35500(16103) Maximum discharge pressure: psi (kPa) “XL” model: 1640 (11307) “L” model: 2502 (17254) “M” model: 4279 (29505) “MS” model: 7232 (49863) Crankshaft extension: Diameter, in.(mm): 7.000 (177.8) Length, in.(mm): 12.000 (304.8) Keyway: width x depth, in.(mm): 1 3/4 x 7/8 (44.45 x 22.22) Maximum recommended sheave diameter, in.(mm): 71 (1803.4) For larger sizes: Contact Customer Service Accessory gear reduction unit: N/A Oil Capacity, gallons (L) Crankcase: 48 (181.7) Gear Reducer - varies with ratio: N/A Weight, pump only on wood shipping skids, pounds (kg) 11125 (5046.3) Weight varies with pump model Standard Materials for Fluid Ends: “XL” model Cast Nickel-Aluminum-Bronze Cast Carbon Steel Cast Duplex Stainless Steel “L” & “M” models Forged Nickel-Aluminum-Bronze Forged & Plate Carbon Steel “MS” model Forged Nickel-Aluminum-Bronze Forged Carbon Steel
Dimensions (Inches) C D E 41 41 62 1/4 46 1/2 46 1/2 65 39 51 1/2 65
F G H 94 1/4 20 3/4 7 1/4 93 20 5/8 11 1/2 93 17 3/16 -3/4
622T-8 Triplex Plunger Pump Performance Data PUMP
622T-8XL (T600-7)
622T-8L (T600-5)
622T-8M (T600-4)
622T-8MS (T600-3)
PUMP
622T-8XL (T600-7)
622T-8L (T600-5)
622T-8M (T600-4)
622T-8MS (T600-3)
English Units Plunger Plunger BPD Dia. Area per In. Sq. In. RPM 7.000 38.4845 137.0875 6.750 35.7847 127.4704 6.500 33.1830 118.2030 6.250 30.6796 109.2853 6.000 28.2743 100.7174 5.750 25.9672 92.4991 5.500 23.7583 84.6306 5.250 21.6475 77.1117 5.000 19.6349 69.9426 4.750 17.7205 63.1232 4.500 15.9043 56.6535 4.250 14.1862 50.5335 4.000 12.5664 44.7633 3.750 11.0447 39.3427 3.500 9.6211 34.2719 3.250 8.2958 29.5508 3.000 7.0686 25.1793 2.750 5.9396 21.1576 2.500 4.9087 17.4857 Brake Horsepower Required
GPM per RPM 3.9984 3.7179 3.4476 3.1875 2.9376 2.6979 2.4684 2.2491 2.0400 1.8411 1.6524 1.4739 1.3056 1.1475 0.9996 0.8619 0.7344 0.6171 0.5100
Max. Press. PSI 922 992 1070 1157 1256 1367 1494 1640 1808 2003 2232 2502 2825 3214 3690 4279 5022 5977 7232
Metric Units Plunger Plunger Dia. Area mm cm2 178 248.286 171 230.868 165 214.084 159 197.932 152 182.415 146 167.530 140 153.279 133 139.661 127 126.677 121 114.326 114 102.608 108 91.524 102 81.073 95 71.256 89 62.072 83 53.521 76 45.604 70 38.320 64 31.669 Kilowatts Required
L/Sec. per RPM 0.2523 0.2346 0.2175 0.2011 0.1853 0.1702 0.1557 0.1419 0.1287 0.1162 0.1042 0.0930 0.0824 0.0724 0.0631 0.0544 0.0463 0.0389 0.0322
100 RPM Max. Press. kPa M3/Hr L/Sec. 6360 90.8 25.2 6840 84.4 23.5 7376 78.3 21.8 7978 72.4 20.1 8657 66.7 18.5 9426 61.3 17.0 10302 56.1 15.6 11307 51.1 14.2 12466 46.3 12.9 13813 41.8 11.6 15390 37.5 10.4 17254 33.5 9.3 19478 29.7 8.2 22161 26.1 7.2 25440 22.7 6.3 29505 19.6 5.4 34627 16.7 4.6 41209 14.0 3.9 49863 11.6 3.2 179
M3/Hr per RPM 0.9080 0.8443 0.7829 0.7239 0.6671 0.6127 0.5606 0.5108 0.4633 0.4181 0.3753 0.3347 0.2965 0.2606 0.2270 0.1957 0.1668 0.1401 0.1158
100 RPM
BPD GPM 13709 399.8 12748 371.8 11821 344.8 10929 318.7 10072 293.8 9250 269.8 8464 246.8 7712 224.9 6995 204.0 6313 184.1 5666 165.2 5054 147.4 4477 130.6 3935 114.7 3428 100.0 2956 86.2 2518 73.4 2116 61.7 1749 51.0 240
150 RPM
175 RPM
BPD GPM 20564 599.8 19121 557.7 17731 517.1 16393 478.1 15108 440.6 13875 404.7 12695 370.3 11567 337.4 10492 306.0 9469 276.2 8499 247.9 7581 221.1 6715 195.8 5902 172.1 5141 149.9 4433 129.3 3777 110.2 3174 92.6 2623 76.5 359
BPD GPM 23991 699.7 22308 650.6 20686 603.3 19125 557.8 17626 514.1 16188 472.1 14811 432.0 13495 393.6 12240 357.0 11047 322.2 9915 289.2 8844 257.9 7834 228.5 6885 200.8 5998 174.9 5172 150.8 4407 128.5 3703 108.0 3060 89.2 419
150 RPM
200 RPM
BPD 27418 25495 23641 21858 20144 18500 16927 15423 13989 12625 11331 10107 8953 7869 6855 5911 5036 4232 3498
175 RPM
M3/Hr L/Sec. 136.2 37.8 126.6 35.2 117.4 32.6 108.6 30.2 100.1 27.8 91.9 25.5 84.1 23.4 76.6 21.3 69.5 19.3 62.7 17.4 56.3 15.6 50.2 13.9 44.5 12.4 39.1 10.9 34.1 9.5 29.4 8.2 25.0 6.9 21.0 5.8 17.4 4.8 268
M3/Hr 158.9 147.8 137.0 126.7 116.7 107.2 98.1 89.4 81.1 73.2 65.7 58.6 51.9 45.6 39.7 34.3 29.2 24.5 20.3
L/Sec. 44.1 41.0 38.1 35.2 32.4 29.8 27.3 24.8 22.5 20.3 18.2 16.3 14.4 12.7 11.0 9.5 8.1 6.8 5.6 312
GPM 799.7 743.6 689.5 637.5 587.5 539.6 493.7 449.8 408.0 368.2 330.5 294.8 261.1 229.5 199.9 172.4 146.9 123.4 102.0 478
200 RPM
M3/Hr 181.6 168.9 156.6 144.8 133.4 122.5 112.1 102.2 92.7 83.6 75.1 66.9 59.3 52.1 45.4 39.1 33.4 28.0 23.2
225 RPM
BPD 30845 28681 26596 24590 22662 20813 19042 17351 15738 14203 12748 11371 10072 8853 7712 6649 5666 4761 3935
GPM 899.6 836.5 775.7 717.2 661.0 607.0 555.4 506.0 459.0 414.2 371.8 331.6 293.8 258.2 224.9 193.9 165.2 138.8 114.7 538
225 RPM
260 RPM
BPD GPM 35643 1039.6 33143 966.7 30733 896.4 28415 828.7 26187 763.8 24050 701.5 22004 641.8 20050 584.8 18186 530.4 16413 478.7 14730 429.6 13139 383.2 11639 339.5 10230 298.3 8911 259.9 7684 224.1 6547 190.9 5501 160.4 4547 132.6 622
260 RPM
L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. 50.5 204.3 56.8 236.1 65.6 46.9 190.0 52.8 219.5 61.0 43.5 176.2 48.9 203.6 56.6 40.2 162.9 45.2 188.2 52.3 37.1 150.1 41.7 173.5 48.2 34.0 137.9 38.3 159.3 44.3 31.1 126.1 35.0 145.7 40.5 28.4 114.9 31.9 132.8 36.9 25.7 104.2 29.0 120.5 33.5 23.2 94.1 26.1 108.7 30.2 20.8 84.4 23.5 97.6 27.1 18.6 75.3 20.9 87.0 24.2 16.5 66.7 18.5 77.1 21.4 14.5 58.6 16.3 67.8 18.8 12.6 51.1 14.2 59.0 16.4 10.9 44.0 12.2 50.9 14.1 9.3 37.5 10.4 43.4 12.0 7.8 31.5 8.8 36.4 10.1 6.4 26.1 7.2 30.1 8.4 357 401 464
Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
625Q-7 Quintuplex Plunger Pump Specifications
1 1/4"x 5/8" KEYWAY
5.998 DIA. 6.000
SUCTION & DISCHARGE CONNECTIONS MAY BE MADE AT EITHER END
14 7/8 (USABLE SHAFT EXT.)
10 3/4
57 21/32
"H" FLUID END ONLY
45 7/8
"C"/2
10 3/4
34 7/8
22 15/16
14 3/8
"C"
"C"
108 1/2
14 3/8
34 7/8
Pump Size maximum plunger size x stroke length, in.(mm): 5 x 7 (127 x 178) Rated bhp at 286 rpm (kw): 625 (466) Rated plunger load, pounds(Kg): 22,200(10,070) Maximum discharge pressure: psi(kPa) “L” model: 1550 (10,687) “M” model: 3150 (21,719) “H” model: 5000 (34,474) Crankshaft extension: in.(mm) Diameter: 6 (152.4) Length long side: 14 7/8 (378) Length short side: 7 5/8 (194) Keyway (width x depth): 1 1/4 x 5/8 (31.8 x 15.9) Oil Capacity, gallons (L): 33 1/2 (127) Weight, pump only on wood shipping skids, pounds (Kg): 17166 (7487) Weight varies with pump model
7 1/2
9
9
5 1/4 7 5/8 (USABLE SHAFT EXT.)
1 1/4" x 5/8" KEYWAY
1 1/2 " DIA. HOLE THRU 4 PLACES AS, SHOWN
"H" FLUID END ONLY
1" STD. PIPE TAP 1 HOLE, THIS SIDE
16
"B"
1" NPT (1 EACH SIDE)
13 3/4
29 9/16
"A"
DISCHARGE CENTERLINE
SUCTION CENTERLINE 2" NPT (CRADLE DRAIN)
52 1/8
15
12 1/2
61 1/4 17
"D" "E" "H" CYLINDER SUCTION DIM. ONLY
Pump Model 625Q-7L 625Q-7M 625Q-7H
Flange Connections Discharge Connection Sizes Suction Connection Sizes A 6 (152.4) API 2000 RJ 10 (254) ANSI 150 FF 10 1/4 4 (101.6) ANSI 1500 RJ 6 (152.4) ANSI 300 FF 5 1/4 3 (76.2) ANSI 2500 RJ 6 (152.4) ANSI 300 FF 5 1/4
Dimensions in inches (mm) B C D E 10 3/4 69 1/4 65 3/8 90 3/8 8 3/4 66 1/2 64 5/8 87 7/8 8 3/4 60 3/4 64 7/8 100 3/8
625Q-7 Quintuplex Plunger Pump Performance Data PUMP
625Q-7L
625Q-7M
625Q-7H
PUMP
625Q-7L
625Q-7M
625Q-7H
English Units Plunger Plunger BPD Dia. Area per In. Sq. In. RPM 5.000 19.6349 102.000 4.750 17.7205 92.055 4.500 15.9043 82.620 4.250 14.1862 73.695 4.000 12.5664 65.280 3.750 11.0447 57.375 3.500 9.6211 49.980 3.250 8.2958 43.095 3.000 7.0686 36.720 3.000 7.0686 36.720 2.750 5.9396 30.855 2.500 4.9087 25.500 2.375 4.4301 23.014 Brake Horsepower Required
GPM per RPM 2.9750 2.6849 2.4097 2.1494 1.9040 1.6734 1.4577 1.2569 1.0710 1.0710 0.8999 0.7437 0.6712
100 RPM Max. Press. PSI BPD GPM 1131 10200 297.5 1253 9206 268.5 1396 8262 241.0 1550 7370 214.9 1767 6528 190.4 2010 5738 167.3 2307 4998 145.8 2676 4310 125.7 3150 3672 107.1 3150 3672 107.1 3738 3086 90.0 4523 2550 74.4 5000 2302 67.1 219
Metric Units Plunger Plunger Dia. Area mm cm2 127 126.677 121 114.326 114 102.608 108 91.524 102 81.073 95 71.256 89 62.072 83 53.521 76 45.604 76 45.604 70 38.320 64 31.669 60 28.581 Kilowatts Required
L/Sec. per RPM 0.1877 0.1694 0.1520 0.1356 0.1201 0.1056 0.0920 0.0793 0.0676 0.0676 0.0568 0.0469 0.0423
100 RPM 150 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 7796 67.6 18.8 101.3 28.2 8638 61.0 16.9 91.5 25.4 9624 54.7 15.2 82.1 22.8 10687 48.8 13.6 73.2 20.3 12181 43.2 12.0 64.9 18.0 13859 38.0 10.6 57.0 15.8 15909 33.1 9.2 49.7 13.8 18451 28.5 7.9 42.8 11.9 21719 24.3 6.8 36.5 10.1 21719 24.3 6.8 36.5 10.1 25770 20.4 5.7 30.7 8.5 31182 16.9 4.7 25.3 7.0 34474 15.2 4.2 22.9 6.4 163 245
M3/Hr per RPM 0.6756 0.6097 0.5473 0.4881 0.4324 0.3800 0.3311 0.2854 0.2432 0.2432 0.2044 0.1689 0.1524
150 RPM
BPD 15300 13809 12393 11055 9792 8607 7497 6465 5508 5508 4629 3825 3453
200 RPM
GPM 446.2 402.7 361.5 322.4 285.6 251.0 218.7 188.5 160.6 160.6 135.0 111.6 100.7 328
BPD 20400 18411 16524 14739 13056 11475 9996 8619 7344 7344 6171 5100 4603
GPM 595.0 537.0 481.9 429.9 380.8 334.7 291.5 251.4 214.2 214.2 180.0 148.7 134.2 437
200 RPM
M3/Hr 135.1 121.9 109.5 97.6 86.5 76.0 66.2 57.1 48.6 48.6 40.9 33.8 30.5
L/Sec. 37.5 33.9 30.4 27.1 24.0 21.1 18.4 15.9 13.5 13.5 11.4 9.4 8.5 326
250 RPM
BPD 25500 23014 20655 18424 16320 14344 12495 10774 9180 9180 7714 6375 5754
GPM 743.7 671.2 602.4 537.4 476.0 418.4 364.4 314.2 267.7 267.7 225.0 185.9 167.8 545
250 RPM
M3/Hr 168.9 152.4 136.8 122.0 108.1 95.0 82.8 71.4 60.8 60.8 51.1 42.2 38.1
275 RPM
BPD 28050 25316 22721 20267 17952 15779 13745 11852 10098 10098 8486 7013 6329
GPM 818.1 738.4 662.7 591.1 523.6 460.2 400.9 345.7 294.5 294.5 247.5 204.5 184.6 600
275 RPM
286 RPM
BPD GPM 29172 850.8 26328 767.9 23630 689.2 21077 614.7 18671 544.5 16410 478.6 14295 416.9 12326 359.5 10502 306.3 10502 306.3 8825 257.4 7293 212.7 6582 192.0 625
286 RPM
L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. 46.9 185.8 51.6 193.2 53.7 42.3 167.7 46.6 174.4 48.4 38.0 150.5 41.8 156.5 43.5 33.9 134.2 37.3 139.6 38.8 30.0 118.9 33.0 123.7 34.4 26.4 104.5 29.0 108.7 30.2 23.0 91.0 25.3 94.7 26.3 19.8 78.5 21.8 81.6 22.7 16.9 66.9 18.6 69.6 19.3 16.9 66.9 18.6 69.6 19.3 14.2 56.2 15.6 58.5 16.2 11.7 46.4 12.9 48.3 13.4 10.6 41.9 11.6 43.6 12.1 406 447 466
Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. Not all plunger sizes are shown. Contact National-Oilwell for additional information. For Operations below 100 RPM, an auxiliary lubrication system is required. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
D-750L Triplex Piston Pump 2.0-11.5NPT CONNECTIONS FOR PRESSURE GAUGE AND RELIEF VALVE
1.25-11.5NPT BOTH ENDS WATER SPRAY CONNECTION
3.7513.7 49 TYP
ÿ
Specifications 6.0-CL-150 RF FLANGE SUCTION CONNECTION (OTHER FLANGES AVAILABLE)
14.62
18
18.88
67.00
36
37.75
7.50
7.12 4.0-API 5000 LB. FLANGE DISCHARGE CONNECTION (OTHER FLANGES AVAILABLE)
1.0 x .5 x 5.25 LONG KEYWAY TYP
36.50
19.56
19.69
24.84
11.63
13.00
10.13
10.00
17.13
9.00
32.00
52.50
107.75
Pump Model D-750L
Flange Connections Discharge Connection Sizes Suction Connection Sizes 4 (101.6) API 5000# 6 (152.4) ANSI 150# RF
44.00
Pump Type: Horizontal Reciprocating Power Pump Positive Displacement with Single-Acting Pistons Maximum Input Horsepower: 750 Continuous Stroke Length: 8 inches Maximum Rod Load: 85,000 Ibs. Approximate Weight: 11,500 Ibs. Pump Power End: Fabricated of High Strength Steel Gears: Double Helical Gear Ratio: 4.95:1 Rod Bearings: Shell Type Replaceable Main Bearings: Straight Roller Pinion Bearings: Spherical Roller Crankshaft: One Piece Forged Alloy Steel Connecting Rod: One Piece Forging Crosshead Guide: Bronze Replaceable Fluid End: Piston Type Segmented Block Design. Machined From High Strength Alloy Steel, Heat Treated and Ultrasonic Tested Piston Diameter: 4.5 to 7 inches Discharge Outlet: 4 API 5000 RJ Suction Inlet: 6 ANSI 150 RF Valves and Seats: API-6 Stem Guided, Hardened Steel Seats Piston Liners: Chrome or Ceramic Sleeved Power End Lubrication: 35 GPM Required, Optional Hydraulic Lubrication System w/ Sump Available
D-750L Triplex Piston Pump Performance Data Pump Speed in Crankshaft Revolutions Per Minute (RPM) Displacement 60 80 100 120 140*** Piston Factors* Flow Max Flow Max Flow Max Flow Max Flow Max Diameter @ 100% V. E. @ 100% V. E. Press. @ 100% V. E. Press. @ 100% V. E. Press. @ 100% V. E. Press. @ 100% V. E. Press. U.S. Gal. U.S. Gal. @ Flow U.S. Gal. @ Flow U.S. Gal. @ Flow U.S. Gal. @ Flow U.S. Gal. @ Flow per Rev. per Min. per Min. per Min. per Min. per Min. Inches GPR GPM PSIG GPM PSIG GPM PSIG GPM PSIG GPM PSIG 7.00 3.999 240 2211 320 2209 400 2208 480 2208 560 1952 6.50 3.448 207 2563 276 2562 345 2561 414 2560 483 2264 6.00 2.938 176 3008 235 3006 294 3005 353 3004 411 2657 5.50 2.468 148 3581 197 3579 247 3577 296 3576 346 3162 5.00 2.040 122 4333 163 4330 204 4328 245 4327 286 3826 4.50 1.652 99 5000 132 5000 165 5000 198 5000 231 4724 Input Brake** 364 485 606 727 750 Power Horsepower Pinion RPM 297 396 495 594 693 @ 4.95:1 Gear Ratio *V.E. = VOLUMETRIC EFFICIENCY, **BHP (Brake Horsepower) is based on 85% Mechanical Efficiency *** Speeds above 120 RPM are not recommended for continuous drilling operations. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
C-1000 Triplex Plunger Pump 21.84
Specifications 13.28
Pump Type: Horizontal Reciprocating Power Pump, Positive Displacement with Single-Acting Plungers Maximum Input Horsepower: 1069 Continuous Stroke Length: 8 inches Maximum Rod Load: 60,000 lbs. Approximate Weight: 13,000 Ibs. Pump Power End: Fabricated of High Strength Steel Gears: Double Helical Gear Ratios: 6.35:1 or 7.0:1 Rod Bearings: Shell Type Replaceable Main Bearings: Straight Roller Pinion Bearings: Spherical Roller Crankshaft: One Piece Forged Alloy Steel Connecting Rod: One Piece Forging Crosshead Guide: Bronze Replaceable Fluid End: Steel Billet Plunger Diameter: 4.5 to 6.75 inches Discharge: 1500 lb. ANSI RF 4” Suction: 150 lb. ANSI RF 8” Valves and Seats: Stainless Steel Disc Type Power End Lubrication: Pressure Lubricated with Removal Oil Sump
66.17
33.63
6.88
4.00 1" NPT (PRESSURE SWITCH)
PINION SHAFT 1.00 WIDTH BY 0.50 DEPTH KEYWAY 1" NPT (OIL PUMP OUTLET)
95.74
61.88
25.76
4"-1500# ANSI RF FLANGE TYP BOTH SIDES
19.06
11.14
44.31
15.89
22.81
11.81
ROTATION 6.75
8" - 150# ANSI RF FLANGE
12.06
12.81
TYP BOTH SIDES
2" FNPT CONNECTION (DRAIN)
30.28
A
33.00
37.00
Pump Model C-1000
18.50
22.50
26.50
Flange Connections Discharge Connection Sizes Suction Connection Sizes 4 (101.6) 1500# ANSI RF 8 (203.2) 150# ANSI RF
A
C-1000 Triplex Plunger Pump Performance Data Plunger Diameter Inches 4.5 5 5.5 6 6.5 6.75
Maximum Pressure psi
Displacement U.S.Gallon per Rev.
3705 1.6524 3055 2.0400 2525 2.4684 2120 2.9376 1810 3.4476 1675 3.779 Minimum Brake Horsepower Required
50 RPM GPM 83 102 123 147 172 186 214
Pump Speed in Crankshaft Revolutions Per Minute (RPM) Displacement 100 150 200 RPM RPM RPM GPM GPM GPM 165 248 330 204 306 408 247 370 494 294 441 588 345 517 690 372 558 744 427 641 855
250 RPM GPM 413 510 617 734 862 929 1069
Brake Horsepower is based on 85% Mechanical Efficiency at the Pinion Shaft. RPM shown is crankshaft speed. For pinion shaft speed, multiply RPM by Gear Ratio. Displacement is based on 100% Volumetric Efficiency. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
535 Duplex Double-Acting Piston Pump ÿ.75 TYP 4 PLACES
Specifications
8.06 6.13 12.25 C C/2 12.25
ÿ
DISCHARGE CONNECTION
.375 X .188 KEYWAY 4.000 LONG
1.500 1.499
6.42 PINION SHAFT ROTATION DIRECTION
Pump Size: maximum piston size x stroke length, in.(mm): 3.500 x 5.125 (88.9 x 130.2) Rated BHP (kW) at 85 RPM (Crankshaft speed): 12.4 (9.3) Rated piston load, pounds (kg): 2500 (1134) Maximum discharge pressure, psi (kPa): 796 (5487) Pinion Gear Ratio : 4.933:1 Pinion shaft extension: Diameter, in. (mm): 1.500 (38.10) Length, in. (mm): 4.188 (4.76) Keyway width x depth, in.(mm): 3/8 x 3/16 (9.525 x 4.763) Maximum recommended sheave diameter, in.(mm): 25.0 (635.0) For larger sheave diameters: Contact Customer Service Oil Capacity, gallons (L): 1.25 (4.7) Weight, pump only on wood shipping skids, pounds (kg): 800 (363) Standard Materials for Fluid End Bodies Cast Gray Iron Cast Ductile Iron
F A 17.25
B
12.46 8.75
SUCTION CONNECTION
.75 TYP
.37
G
D 8.13 40.50 SUCTION E
Pump Model 535
Flange Connections Discharge Connection Sizes Suction Connection Sizes A B 6 7/16 4 1/2 2 (50.8)-8 NPT 2 1/2 (63.5)-8 NPT
C 20
Dimensions (Inches) D E F 34 1/4 50 7/8
8
G
H
J
33 3/8
2 5/8
3
K
L
31 1/4 13 3/4
535 Duplex Double-Acting Piston Pump Performance Data PUMP
535
PUMP
535
English Units Piston Piston BPD Dia. Area per In. Sq. In. RPM 2.000 3.1416 8.3623 2.500 4.9087 13.7383 3.000 7.0686 20.3074 3.500 9.6211 28.0766 Brake Horsepower Required
GPM per RPM 0.2439 0.4007 0.5923 0.8189
Metric Units Plunger Plunger Dia. Area mm cm2 51 20.268 64 31.669 76 45.604 89 62.072 Kilowatts Required
L/Sec. per RPM 0.0154 0.0253 0.0374 0.0517
M3/Hr per RPM 0.0554 0.0910 0.1345 0.1860
25 RPM Max. Press. PSI 796 509 354 260
BPD 210 344 508 702
GPM 6.1 10.0 14.8 20.5 3.7
40 RPM
BPD 335 550 813 1124
55 RPM
GPM 9.8 16.0 23.7 32.8 5.9
BPD 460 756 1117 1545
GPM 13.4 22.0 32.6 45.0
70 RPM
BPD 586 962 1422 1966
8.0
25 RPM 40 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 5487 1.4 0.4 2.2 0.6 3511 2.3 0.6 3.6 1.0 2439 3.4 0.9 5.4 1.5 1792 4.6 1.3 7.4 2.1 2.7 4.4
55 RPM
M3/Hr 3.0 5.0 7.4 10.2
L/Sec. 0.8 1.4 2.1 2.8 6.0
GPM 17.1 28.0 41.5 57.3 10.2
70 RPM
M3/Hr 3.9 6.4 9.4 13.0
85 RPM
BPD 711 1168 1727 2387
GPM 20.7 34.1 50.3 69.6 12.4
85 RPM
L/Sec. M3/Hr L/Sec. 1.1 4.7 1.3 1.8 7.7 2.1 2.6 11.4 3.2 3.6 15.8 4.4 7.6 9.3
RPM shown is Crankshaft speed. For Pinion Shaft speed, multiply RPM by Gear Ratio. Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 85% Mechanical Efficiency. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
1847-A Duplex Double-Acting Piston Pump 3.75 MTG.PFEET
Specifications Pump Size: maximum piston size x stroke length, in.(mm): 4-1/2 x 6 (114.3 x 152.4) Rated BHP (kW) at 100 RPM (Crankshaft speed): 33 (25) Rated piston load, pounds (kg): 4850 (2200) Maximum discharge pressure, psi (kPa): 990 (6826) Pinion gear ratio: 5.100:1 Pinion shaft extension: Diameter, in.(mm): 1.750 (44.45) Length, in.(mm): 5.625 (142.88) Keyway width x depth, in.(mm): 3/8 x 3/16 (9.525 x 4.763) Maximum recommended sheave diameter, in.(mm): 38 (965) For larger sheave diameters: Contact Customer Service Oil Capacity, gallons (L): 5.0 (18.9) Weight, pump only on wood shipping skids, pounds (kg): 1960 (889) Standard Materials for Fluid End Bodies Cast Steel Cast Ductile Iron
5.65 3.50 13.25
15.50PM TG.PFEET
7.75PMT G.PFEET C
3.50
13.25
%%C.750PTYPP6 PLACES
3.75 MTG.PFEET
.375 x .188 KEYWAYP6.125 LONG
%%C2.499 ^2.500;
6.53
DIRECTION ROTATION
DISCHARGEPCONNEC TION
POF
23.06 F
A 19.63
17.16 9.75
B
1.25
.88 2.00 5.00
SUCTIONPCONNECTI ON
14.63 5.00 D
G
E
Pump Model 1847-A
Flange Connections
Dimensions (Inches)
Discharge Connection Sizes
Suction Connection Sizes
By-Pass Connection Sizes
A
B
C
D
E
F
G
2 (50.8)-600# ANSI FF
4 (101.6)-150# ANSI FF
None
7 1/4
8 5/8
26 1/2
42 5/8
65 15/16
11 7/8
8 5/8
1847-A Duplex Double-Acting Piston Pump Performance Data PUMP
1847-A
PUMP
1847-A
English Units Piston Piston BPD Dia. Area per In. Sq. In. RPM 2.500 4.9087 15.7680 3.000 7.0686 23.4480 3.500 9.6211 32.3520 4.000 12.5664 42.9120 4.500 15.9043 54.8640 Brake Horsepower Required
GPM per RPM 0.4599 0.6839 0.9436 1.2516 1.6002
Metric Units Plunger Plunger Dia. Area mm cm2 64 31.669 76 45.604 89 62.072 102 81.073 114 102.608 Kilowatts Required
L/Sec. per RPM 0.0290 0.0431 0.0595 0.0790 0.1010
M3/Hr per RPM 0.1044 0.1553 0.2143 0.2842 0.3634
20 RPM Max. Press. PSI 990 686 504 386 305
BPD 316 469 648 859 1098
GPM 9.2 13.7 18.9 25.0 32.0 7
40 RPM
BPD 631 938 1295 1717 2195
60 RPM
GPM 18.4 27.4 37.7 50.1 64.0
BPD 947 1407 1942 2575 3292
13
20 RPM 40 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 6812 2.1 0.6 4.2 1.2 4731 3.1 0.9 6.2 1.7 3476 4.3 1.2 8.6 2.4 2661 5.7 1.6 11.4 3.2 2103 7.3 2.0 14.5 4.0 5 10
GPM 27.6 41.0 56.6 75.1 96.0
80 RPM
BPD 1262 1876 2589 3433 4390
GPM 36.8 54.7 75.5 100.1 128.0
100 RPM
BPD 1577 2345 3236 4292 5487
GPM 46.0 68.4 94.4 125.2 160.0
20
27
33
60 RPM
80 RPM
100 RPM
M3/Hr 6.3 9.3 12.9 17.1 21.8
L/Sec. 1.7 2.6 3.6 4.7 6.1 15
M3/Hr 8.4 12.4 17.1 22.7 29.1
L/Sec. M3/Hr L/Sec. 2.3 10.4 2.9 3.5 15.5 4.3 4.8 21.4 6.0 6.3 28.4 7.9 8.1 36.3 10.1 20 25
RPM shown is Crankshaft speed. For Pinion Shaft speed, multiply RPM by Gear Ratio. Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 85% Mechanical Efficiency. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
1550 Duplex Double-Acting Piston Pump Specifications SHAFT
15.00 TYP 10.50
6.75 CL
31.00
PUMP
PINION SHAFT
21.00
13.50
CRANK
4.13
22.63
ÿ1.00 TYP 6 PLACES 2.500 2.499
ÿ
.625 X .313 KEYWAY
DISCHARGE CONNECTION 3.00 - 600# ANSI
PINION ROTATION
14.25 8.75
32.18
28.00 22.00 9.25 14.25 2.00 TYP 5.00
1.75 11.50 SUCTION CONNECTION 4.00-150# ANSI 42.75 7.13 TYP
62.90
93.00
Pump Model 1550
Flange Connections Discharge Connection Sizes Suction Connection Sizes 3 (76.2) 600# ANSI 4 (101.6) 150# ANSI
10.10
Pump Size: maximum piston size x stroke length, in.(mm): 5 x 10 (127.0 x 254.0) Rated BHP (kW) at 85 RPM (Crankshaft speed): 74 (55) Rated piston load, pounds (kg): 7475 (3391) Maximum discharge pressure, psi (kPa): 1440 (9929) Pinion gear ratio: 5.92:1 Pinion shaft extension: Diameter, in.(mm): 2.500 (61.25) Length, in.(mm): 6.813 (173.0) Keyway: Width x Depth, in.(mm): 5/8 x 5/16 (15.875 x 7.938) Maximum recommended sheave diameter, in.(mm): 44 (1118) For larger sheave diameters: Contact Customer Service Oil Capacity, gallons (L): 10.0 (37.85) Weight, pump only on wood shipping skids, pounds (kg): 3705 (1681) Standard Materials for Fluid End Bodies Cast Carbon Steel Cast Ductile Iron
1550 Duplex Double-Acting Piston Pump Performance Data PUMP
1550
PUMP
1550
English Units Piston Piston BPD Dia. Area per In. Sq. In. RPM 2.500 4.9087 26.1908 3.000 7.0686 39.0137 3.500 9.6211 54.1680 4.000 12.5664 71.6537 4.500 15.9043 91.4708 5.000 19.6349 113.6194 Brake Horsepower Required
GPM per RPM 0.7639 1.1379 1.5799 2.0899 2.6679 3.3139
Metric Units Plunger Plunger Dia. Area mm cm2 64 31.669 76 45.604 89 62.072 102 81.073 114 102.608 127 126.677 Kilowatts Required
L/Sec. per RPM 0.0482 0.0718 0.0997 0.1319 0.1683 0.2091
M3/Hr per RPM 0.1735 0.2584 0.3588 0.4746 0.6059 0.7526
25 RPM Max. Press. PSI 1400 1057 777 595 470 381
BPD 655 976 1355 1792 2287 2841
GPM 19.1 28.4 39.5 52.2 66.7 82.8 22
40 RPM
BPD 1048 1561 2167 2867 3659 4545
55 RPM
GPM 30.6 45.5 63.2 83.6 106.7 132.6
BPD 1441 2146 2980 3941 5031 6250
35
25 RPM 40 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 9929 4.3 1.2 6.9 1.9 7291 6.5 1.8 10.3 2.9 5357 9.0 2.5 14.4 4.0 4101 11.9 3.3 19.0 5.3 3241 15.1 4.2 24.2 6.7 2625 18.8 5.2 30.1 8.4 16 26
GPM 42.0 62.6 86.9 114.9 146.7 182.3
70 RPM
BPD 1834 2731 3792 5016 6403 7954
GPM 53.5 79.7 110.6 146.3 186.8 232.0
85 RPM
BPD 2227 3317 4605 6091 7776 9658
GPM 64.9 96.7 134.3 177.6 226.8 281.7
48
61
74
55 RPM
70 RPM
85 RPM
M3/Hr 9.5 14.2 19.7 26.1 33.3 41.4
L/Sec. 2.7 3.9 5.5 7.3 9.3 11.5 36
M3/Hr 12.1 18.1 25.1 33.2 42.4 52.7
L/Sec. M3/Hr L/Sec. 3.4 14.7 4.1 5.0 22.0 6.1 7.0 30.5 8.5 9.2 40.3 11.2 11.8 51.5 14.3 14.6 64.0 17.8 45 55
RPM shown is Crankshaft speed. For Pinion Shaft speed, multiply RPM by Gear Ratio. Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 85% Mechanical Efficiency. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
1654 Duplex Double-Acting Piston Pump ÿ 1.00 TYP 8 PLACES
14.88
14.88
Specifications
15.76
12.00
12.00
12.00
12.00 15.76
11.12
3/8" x 3/4" x 10" LONG KEYWAY ÿ
3.000 2.999
26.08
50.12
14.88
DISCHARGE 3"-2000# API RTJ FLANGE
10.50 ROTATION DIRECTION
10.25 DISCHARGE
SUCTION 4"-300# ANSI FLANGE
32.88 23.92
21.13 DISCHARGE 12.75
1.25
1.75
1.63
2.25 2.50 1" NPT DRAIN HOLE ON EACH CYLINDER C
11.63
5.00
L
22.00
3.38 SUCTION
47.75 10.00 SUCTION
Pump Model 1654
Flange Connections Discharge Connection Sizes Suction Connection Sizes 3 (76.2) 2000 API RTJ 4 (101.6) 3000# API RTJ
Pump Size: maximum piston size x stroke length, in.(mm): 5 x 8 (127.0 x 203.2) Rated BHP (kW) at 90 RPM (Crankshaft speed): 104 (77) Rated piston load, pounds (kg): 12680 (5752) Maximum discharge pressure, psi (kPa): 1800 (12411) Pinion gear ratio: 4.750:1 Pinion shaft extension: Diameter, in.(mm): 3.000 (76.20) Length, in.(mm): 11.000 (279.40) Keyway width x depth, in.(mm): 3/4 x 3/8 (19.05 x 9.525) Maximum recommended sheave diameter, in.(mm): 44 (1118) For larger sheave diameters: Contact Customer Service Oil Capacity, gallons (L): 12.0 (45.42) Weight, pump only on wood shipping skids, pounds (kg): 4475 (2030) Standard Materials for Fluid End Bodies Cast Steel Cast Ductile Iron
1654 Duplex Double-Acting Piston Pump Performance Data PUMP
1654
PUMP
1654
English Units Piston Piston BPD Dia. Area per In. Sq. In. RPM 2.500 4.9087 19.1177 3.000 7.0686 29.3760 3.500 9.6211 41.4720 4.000 12.5664 55.4880 4.500 15.9043 71.3417 5.000 19.6349 89.0605 Brake Horsepower Required
GPM per RPM 0.5576 0.8568 1.2096 1.6184 2.0808 2.5976
Metric Units Plunger Plunger Dia. Area mm cm2 64 31.669 76 45.604 89 62.072 102 81.073 114 102.608 127 126.677 Kilowatts Required
L/Sec. per RPM 0.0352 0.0541 0.0763 0.1021 0.1313 0.1639
M3/Hr per RPM 0.1266 0.1946 0.2747 0.3675 0.4725 0.5899
30 RPM Max. Press. PSI 1800 1794 1318 1009 797 646
BPD 574 882 1245 1665 2141 2672
GPM 16.7 25.7 36.3 48.6 62.4 77.9 35
45 RPM
BPD 861 1322 1867 2497 3211 4008
60 RPM
GPM 25.1 38.6 54.4 72.8 93.6 116.9
BPD 1148 1763 2489 3330 4281 5344
52
30 RPM 45 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 12411 3.8 1.1 5.7 1.6 12368 5.8 1.6 8.8 2.4 9087 8.2 2.3 12.4 3.4 6957 11.0 3.1 16.5 4.6 5497 14.2 3.9 21.3 5.9 4453 17.7 4.9 26.5 7.4 26 39
GPM 33.5 51.4 72.6 97.1 124.8 155.9
75 RPM
BPD 1434 2204 3111 4162 5351 6680
GPM 41.8 64.3 90.7 121.4 156.1 194.8
69
86
60 RPM
75 RPM
M3/Hr 7.6 11.7 16.5 22.1 28.4 35.4
L/Sec. 2.1 3.2 4.6 6.1 7.9 9.8 52
M3/Hr 9.5 14.6 20.6 27.6 35.4 44.2
90 RPM
BPD 1721 2644 3733 4994 6421 8016
GPM 50.2 77.1 108.9 145.7 187.3 233.8 104
90 RPM
L/Sec. M3/Hr L/Sec. 2.6 11.4 3.2 4.1 17.5 4.9 5.7 24.7 6.9 7.7 33.1 9.2 9.8 42.5 11.8 12.3 53.1 14.7 64 77
RPM shown is Crankshaft speed. For Pinion Shaft speed, multiply RPM by Gear Ratio. Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 85% Mechanical Efficiency. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
1757 Plunger Pump ÿ1.13 TYP 2 PLACES
34.67
Specifications Pump Size: maximum piston size x stroke length, in.(mm): 5-1/2 x 10 (139.7 x 254.0) Rated BHP (kW) at 85 RPM (Crankshaft speed): 127 (95) Rated piston load, pounds (kg): 13100 (5942) Maximum discharge pressure, psi (kPa): 1750 (12066) Pinion gear ratio: 5.846:1 Pinion shaft extension: Diameter, in.(mm): 2.938 (74.61) Length, in.(mm): 13.750 (349.25) Keyway width x depth, in.(mm): 3/4 x 3/8 (19.05 x 9.525) Maximum recommended sheave diameter, in.(mm): 50 (1270) For larger sheave diameters: Contact Customer Service Oil Capacity, gallons (L): 15.0 (56.8) Weight, pump only on wood shipping skids, pounds (kg): 6125 (2778) Standard Materials for Fluid End Bodies Cast Steel Cast Ductile Iron
6.56
19.25 11.75 8.50 23.50
17.00
20.50
C
ÿ1.25 TYP 4 PLACES
.750 X .375 KAYWAY 12.750 LONG 2.938 2.939
ÿ
14.89 BY-PASS CONNECTION
DIRECTION OF ROTATION
DISCHARGE CONNECTION
F
39.50 A 34.63
28.00
B 18.25
2.25
1.00
1.25
SUCTION CONNECTION
9.41 2.75 9.09
21.63
G
D
E
Pump Model 1757
Flange Connections
Dimensions (Inches)
Discharge Connection Sizes
Suction Connection Sizes
By-Pass Connection Sizes
A
B
C
D
E
F
G
3 (76.2)-600# ANSI FF
4 (101.6)-150# ANSI FF
None
8 1/4
1
38 1/2
73 3/8
111 7/16
13 5/8
13 1/4
1757 Plunger Pump Performance Data PUMP
1757
PUMP
1757
English Units Piston Piston BPD Dia. Area per In. Sq. In. RPM 2.500 4.9087 23.9280 3.000 7.0686 36.6960 3.500 9.6211 51.9120 4.000 12.5664 69.3360 4.500 15.9043 89.2080 5.000 19.6349 111.288 5.500 23.7583 135.840 Brake Horsepower Required
GPM per RPM 0.6979 1.0703 1.5141 2.0223 2.6019 3.2459 3.9620
Metric Units Plunger Plunger Dia. Area mm cm2 64 31.669 76 45.604 89 62.072 102 81.073 114 102.608 127 126.677 140 153.279 Kilowatts Required
L/Sec. per RPM 0.0440 0.0675 0.0955 0.1276 0.1642 0.2048 0.2500
M3/Hr per RPM 0.1585 0.2431 0.3439 0.4593 0.5909 0.7371 0.8998
25 RPM Max. Press. PSI 1750 1750 1362 1042 824 667 551
BPD 599 918 1298 1734 2231 2783 3396
GPM 17.4 26.8 37.9 50.6 65.0 81.1 99.1 37
40 RPM
BPD 958 1468 2077 2774 3569 4452 5434
GPM 27.9 42.8 60.6 80.9 104.1 129.8 158.5
55 RPM
BPD 1317 2019 2856 3814 4907 6121 7472
60
25 RPM 40 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 12066 4.0 1.1 6.3 1.8 12066 6.1 1.7 9.7 2.7 9388 8.6 2.4 13.8 3.8 7188 11.5 3.2 18.4 5.1 5679 14.8 4.1 23.6 6.6 4600 18.4 5.1 29.5 8.2 3802 22.5 6.2 36.0 10.0 28 45
GPM 38.4 58.9 83.3 111.2 143.1 178.5 217.9
70 RPM
BPD 1675 2569 3634 4854 6245 7791 9509
82 55 RPM
M3/Hr 8.7 13.4 18.9 25.3 32.5 40.5 49.5
L/Sec. 2.4 3.7 5.3 7.0 9.0 11.3 13.7 61
GPM 48.9 74.9 106.0 141.6 182.1 227.2 277.3 105
70 RPM
M3/Hr 11.1 17.0 24.1 32.1 41.4 51.6 63.0
85 RPM
BPD 2034 3120 4413 5894 7583 9460 11547
GPM 59.3 91.0 128.7 171.9 221.2 275.9 336.8 127
85 RPM
L/Sec. M3/Hr L/Sec. 3.1 13.5 3.7 4.7 20.7 5.7 6.7 29.2 8.1 8.9 39.0 10.8 11.5 50.2 14.0 14.3 62.7 17.4 17.5 76.5 21.2 78 95
RPM shown is Crankshaft speed. For Pinion Shaft speed, multiply RPM by Gear Ratio. Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 85% Mechanical Efficiency. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
1759 Duplex Double-Acting Piston Pump ÿ1.13 TYP 2 PLACES
34.67
Specifications Pump Size: maximum piston size x stroke length, in.(mm): 7-1/2 x 10 (190.5 x 254.0) Rated BHP (kW) at 85 RPM (Crankshaft speed): 130 (97) Rated piston load, pounds (kg): 13100 (5942) Maximum discharge pressure, psi (kPa): 1042 (7188) Pinion gear ratio: 5.846:1 Pinion shaft extension: Diameter, in.(mm): 2.938 (74.61) Length, in.(mm): 13.750 (349.25) Keyway width x depth, in.(mm): 3/4 x 3/8 (19.05 x 9.525) Maximum recommended sheave diameter, in.(mm): 50 (1270) For larger sheave diameters: Contact Customer Service Oil Capacity, gallons (L): 15.0 (56.8) Weight, pump only on wood shipping skids, pounds (kg): 7012 (3181) Standard Materials for Fluid End Bodies Cast Steel Cast Ductile Iron
6.56
19.25 11.75 8.50 23.50
17.00
20.50
C
ÿ1.25 TYP 4 PLACES
.750 X .375 KAYWAY 12.750 LONG 2.938 2.939
ÿ
14.89 BY-PASS CONNECTION
DIRECTION OF ROTATION
DISCHARGE CONNECTION
F
39.50 A 34.63
28.00
B 18.25
2.25
1.00
1.25
SUCTION CONNECTION
9.41 2.75 9.09
21.63
G
D
E
Pump Model 1759
Flange Connections
Dimensions (Inches)
Discharge Connection Sizes
Suction Connection Sizes
By-Pass Connection Sizes
A
B
C
D
E
F
G
4 (101.6)-150# ANSI FF
6 (152.4)-150# ANSI FF
3 (76.2)-600# ANSI FF
11 3/8
11 3/4
43 1/2
74 5/8
111 15/16
17 5/8
12 1/2
1759 Duplex Double-Acting Piston Pump Performance Data PUMP
1759
PUMP
1759
English Units Piston Piston BPD Dia. Area per In. Sq. In. RPM 4.000 12.5664 69.3360 4.500 15.9043 89.2080 5.000 19.6349 111.288 5.500 23.7583 135.840 6.000 28.2743 162.576 6.500 33.1830 191.664 7.000 38.4845 223.200 7.500 44.1786 257.040 Brake Horsepower Required
GPM per RPM 2.0223 2.6019 3.2459 3.9620 4.7418 5.5902 6.5100 7.4970
Metric Units Plunger Plunger Dia. Area mm cm2 102 81.073 114 102.608 127 126.677 140 153.279 152 182.415 165 214.084 178 248.286 191 285.023 Kilowatts Required
L/Sec. per RPM 0.1276 0.1642 0.2048 0.2500 0.2992 0.3527 0.4107 0.4730
M3/Hr per RPM 0.4593 0.5909 0.7371 0.8998 1.0769 1.2695 1.4784 1.7026
25 RPM Max. Press. PSI 1042 824 667 551 463 395 340 297
BPD 1734 2231 2783 3396 4065 4792 5580 6426
GPM 50.6 65.0 81.1 99.1 118.5 139.8 162.8 187.4 38
40 RPM
BPD 2774 3569 4452 5434 6504 7667 8928 10282
GPM 80.9 104.1 129.8 158.5 189.7 223.6 260.4 299.9
55 RPM
BPD 3814 4907 6121 7472 8942 10542 12276 14138
61
25 RPM 40 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 7188 11.5 3.2 18.4 5.1 5679 14.8 4.1 23.6 6.6 4600 18.4 5.1 29.5 8.2 3802 22.5 6.2 36.0 10.0 3194 26.9 7.5 43.1 12.0 2722 31.7 8.8 50.8 14.1 2347 37.0 10.3 59.1 16.4 2044 42.6 11.8 68.1 18.9 28 46
GPM 111.2 143.1 178.5 217.9 260.8 307.5 358.1 412.3
70 RPM
BPD 4854 6245 7791 9509 11381 13417 15624 17993
84 55 RPM
M3/Hr 25.3 32.5 40.5 49.5 59.2 69.8 81.3 93.6
L/Sec. 7.0 9.0 11.3 13.7 16.5 19.4 22.6 26.0 63
GPM 141.6 182.1 227.2 277.3 331.9 391.3 455.7 524.8 107
70 RPM
M3/Hr 32.1 41.4 51.6 63.0 75.4 88.9 103.5 119.2
85 RPM
BPD 5894 7583 9460 11547 13819 16292 18972 21849
GPM 171.9 221.2 275.9 336.8 403.1 475.2 553.4 637.2 130
85 RPM
L/Sec. M3/Hr L/Sec. 8.9 39.0 10.8 11.5 50.2 14.0 14.3 62.7 17.4 17.5 76.5 21.2 20.9 91.5 25.4 24.7 107.9 30.0 28.8 125.7 34.9 33.1 144.7 40.2 80 97
RPM shown is Crankshaft speed. For Pinion Shaft speed, multiply RPM by Gear Ratio. Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 85% Mechanical Efficiency. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
2651 Duplex Double-Acting Piston Pump ÿ1.25 TYP 4 PLACES
Specifications
25.69 TYP
Pump Size: maximum piston size x stroke length, in.(mm): 5-1/2 x 12 (139.7 x 304.8) Rated BHP (kW) at 85 RPM (Crankshaft speed): 250 (187) Rated piston load, pounds (kg): 22100(10025) Maximum discharge pressure, psi (kPa): 1760 (12134) Pinion gear ratio: 5.05:1 Pinion shaft extension: Diameter, in.(mm): 4.250 (107.95) Length, in.(mm): 18.750 (476.25) Keyway width x depth, in.(mm): 1 x 1/2 (25.4 x 12.7) Maximum recommended sheave diameter, in.(mm): 63 (1600) For larger sheave diameters: Contact Customer Service Oil Capacity, gallons (L): 25.0 (94.6) Weight, pump only on wood shipping skids, pounds (kg): 16000(7258) Standard Materials for Fluid End Bodies Cast Steel
18.88 TYP
17.00 12.00
8.00 TYP
C
24.00
34.00
43.25
ÿ1.50 TYP 6 PLACES
4.250 4.249
13.00 BY-PASS
1.00 X 1.50 KEYWAY 16.00 LONG
ÿ
DISCHARGE CONNECTION
BY-PASS CONNECTION 16.25 ROTATION DIRECTION
G
F 52.00
A
45.75
39.81
B 23.50
3.50 TYP
37.88
10.00 TYP
33.62
SUCTION CONNECTION 3 PLACES
13.00 SUCTION 61.75
D
E
Pump Model 2651
Flange Connections
Dimensions (Inches)
Discharge Connection Sizes
Suction Connection Sizes
By-Pass Connection Sizes
A
B
C
D
E
F
G
4 (101.6)-900# ANSI FF
8 (203.2)-300# ANSI FF
2 (50.8)-1500# ANSI FF
10 1/2
14 3/4
49 1/2
86 1/4
131 13/16
17 5/8
13 1/4
2651 Duplex Double-Acting Piston Pump Performance Data PUMP
2651
PUMP
2651
English Units Piston Piston BPD Dia. Area per In. Sq. In. RPM 4.000 12.5664 78.3840 4.500 15.9043 102.096 5.000 19.6349 128.712 5.500 23.7583 158.064 Brake Horsepower Required
GPM per RPM 2.2862 2.9778 3.7541 4.6102
Max. Press. PSI 1760 1390 1126 930
Metric Units Plunger Plunger Dia. Area mm cm2 102 81.073 114 102.608 127 126.677 140 153.279 Kilowatts Required
L/Sec. per RPM 0.1442 0.1879 0.2368 0.2909
25 RPM 40 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 12134 13.0 3.6 20.8 5.8 9581 16.9 4.7 27.1 7.5 7760 21.3 5.9 34.1 9.5 6414 26.2 7.3 41.9 11.6 55 88
M3/Hr per RPM 0.5192 0.6763 0.8526 1.0470
25 RPM
BPD 1960 2553 3218 3952
GPM 57.2 74.4 93.9 115.3 74
40 RPM
BPD 3136 4084 5149 6323
55 RPM
GPM 91.4 119.1 150.2 184.4 118
BPD 4312 5616 7080 8694
GPM 125.7 163.8 206.5 253.6 162
55 RPM
M3/Hr 28.6 37.2 46.9 57.6
L/Sec. 7.9 10.3 13.0 16.0 121
70 RPM
BPD 5487 7147 9010 11065
GPM 160.0 208.4 262.8 322.7 206
70 RPM
M3/Hr 36.3 47.3 59.7 73.3
85 RPM
BPD 6663 8679 10941 13436
GPM 194.3 253.1 319.1 391.9 250
85 RPM
L/Sec. M3/Hr L/Sec. 10.1 44.1 12.3 13.2 57.5 16.0 16.6 72.5 20.1 20.4 89.0 24.7 154 187
RPM shown is Crankshaft speed. For Pinion Shaft speed, multiply RPM by Gear Ratio. Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 85% Mechanical Efficiency. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
2652 Duplex Double-Acting Piston Pump ÿ1.25 TYP 4 PLACES
Specifications
25.69 TYP
Pump Size: maximum piston size x stroke length, in.(mm): 7-1/4 x 12 (184.2 x 304.8) Rated BHP (kW) at 85 RPM (Crankshaft speed): 258 (192) Rated piston load, pounds (kg): 22100(10025) Maximum discharge pressure, psi (kPa): 1125 (7757) Pinion gear ratio: 5.05:1 Pinion shaft extension: Diameter, in.(mm): 4.250 (107.95) Length, in.(mm): 18.750 (476.25) Keyway width x depth, in.(mm): 1 x 1/2 (25.4 x 12.7) Maximum recommended sheave diameter, in.(mm): 63 (1600) For larger sheave diameters: Contact Customer Service Oil Capacity, gallons (L): 25.0 (94.6) Weight, pump only on wood shipping skids, pounds (kg): 15500(7031) Standard Materials for Fluid End Bodies Cast Steel
18.88 TYP
17.00 12.00
8.00 TYP
C
24.00
34.00
43.25
ÿ1.50 TYP 6 PLACES
4.250 4.249
13.00 BY-PASS
1.00 X 1.50 KEYWAY 16.00 LONG
ÿ
DISCHARGE CONNECTION
BY-PASS CONNECTION 16.25 ROTATION DIRECTION
G
F 52.00
A
45.75
39.81
B 23.50
3.50 TYP
37.88
10.00 TYP
33.62
SUCTION CONNECTION 3 PLACES
13.00 SUCTION 61.75
D
E
Pump Model 2652
Flange Connections
Dimensions (Inches)
Discharge Connection Sizes
Suction Connection Sizes
By-Pass Connection Sizes
A
B
C
D
E
F
G
4 (101.6)-600# ANSI FF
8 (203.2)-300# ANSI FF
2 (50.8)-600# ANSI FF
1
14 3/4
49 1/2
86 1/4
131 9/16
19 1/8
1
2652 Duplex Double-Acting Piston Pump Performance Data PUMP
2652
PUMP
2652
English Units Piston Piston BPD Dia. Area per In. Sq. In. RPM 4.000 12.5664 78.3840 4.500 15.9043 102.096 5.000 19.6349 128.712 5.500 23.7583 158.064 6.000 28.2743 190.296 6.500 33.1830 225.120 7.000 38.4845 262.968 7.250 41.2825 283.272 Brake Horsepower Required
GPM per RPM 2.2862 2.9778 3.7541 4.6102 5.5503 6.5660 7.6699 8.2621
Max. Press. PSI 1125 1125 1125 930 782 666 574 535
Metric Units Plunger Plunger Dia. Area mm cm2 102 81.073 114 102.608 127 126.677 140 153.279 152 182.415 165 214.084 178 248.286 184 266.338 Kilowatts Required
L/Sec. per RPM 0.1442 0.1879 0.2368 0.2909 0.3502 0.4142 0.4839 0.5213
25 RPM 40 RPM Max. Press. kPa M3/Hr L/Sec. M3/Hr L/Sec. 7757 13.0 3.6 20.8 5.8 7757 16.9 4.7 27.1 7.5 7757 21.3 5.9 34.1 9.5 6414 26.2 7.3 41.9 11.6 5389 31.5 8.8 50.4 14.0 4592 37.3 10.4 59.6 16.6 3959 43.5 12.1 69.7 19.4 3691 46.9 13.0 75.1 20.9 57 91
M3/Hr per RPM 0.5192 0.6763 0.8526 1.0470 1.2605 1.4911 1.7418 1.8763
25 RPM
BPD 1960 2553 3218 3952 4758 5628 6575 7082
GPM 57.2 74.4 93.9 115.3 138.8 164.2 191.7 206.6 76
40 RPM
BPD GPM 3136 91.4 4084 119.1 5149 150.2 6323 184.4 7612 222.0 9005 262.6 10519 306.8 11331 330.5 121
55 RPM
BPD 4312 5616 7080 8694 10467 12382 14464 15580
GPM 125.7 163.8 206.5 253.6 305.3 361.1 421.8 454.4 167
55 RPM
M3/Hr 28.6 37.2 46.9 57.6 69.3 82.0 95.8 103.2
L/Sec. 7.9 10.3 13.0 16.0 19.3 22.8 26.6 28.7 125
70 RPM
BPD 5487 7147 9010 11065 13321 15759 18408 19830
GPM 160.0 208.4 262.8 322.7 388.5 459.6 536.9 578.3 213
70 RPM
M3/Hr 36.3 47.3 59.7 73.3 88.2 104.4 121.9 131.3
85 RPM
BPD 6663 8679 10941 13436 16176 19136 22353 24079
GPM 194.3 253.1 319.1 391.9 471.8 558.1 651.9 702.3 258
85 RPM
L/Sec. M3/Hr L/Sec. 10.1 44.1 12.3 13.2 57.5 16.0 16.6 72.5 20.1 20.4 89.0 24.7 24.5 107.1 29.8 29.0 126.7 35.2 33.9 148.1 41.1 36.5 159.5 44.3 158 192
RPM shown is Crankshaft speed. For Pinion Shaft speed, multiply RPM by Gear Ratio. Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 85% Mechanical Efficiency. The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
JWS-185 Triplex Well Service Pump 15 5/8 3.000 2.999
DIA
Specifications
DIA
3/4 "X 3/8 " KEYWAY
SUCTION AND DISCHARGE CONNECTIONS MAY BE MADE AT EITHER END
8 1/8
9 7/16
6 3/16
4.125 4.123
36" SUCTION
27" DISCHARGE
13 1/8
7 1/2
51 7/8
7 1/2
26 1/4
26 15/16
1" x 1/2 " KEYWAY
5 7/8
1 1/8 " DIA HOLES 4 PLACES AS SHOWN 1" x 1/2 " KEYWAY 4.125 4.123
SHAFT EXTENSION FOR DIRECT DRIVE
DIA 48 3/4
14 1/2 36 1/2
2 1/16 " API-10,000# RING JOINT FLANGE
1 1/2 " STD PIPE TAP CRADLE DRAIN, BOTH SIDES
+
24 15/16
29
6 3/16
CENTERLINE DISCHARGE
9 3/4 1 1/2 " STD PIPE TAP MUD TRAP DRAIN
3 3/4
7 3/4
2" STD PIPE TAP CRADLE DRAIN
19 3/4 40 3/4 67 1/4
1" STD PIPE TAP POWER END OIL DRAIN
Pump Model JWS-185
Flange Connections Discharge Connection Sizes Suction Connection Sizes 2 1/16 API 10,000# RJ 6 STD Pipe
SUCTION 6" SCH. 40 BFW PIPE
13 1/16
6"
10
CENTERLINE SUCTION
2 1/4
12 1/4
7
2 1/4
Pump Size max. plunger dia. x stroke) in.(mm): 4 x 5 (102 x 127) Rated bhp at 450 rpm (kw): 185 (137.9) Maximum pressure: psi(kPa): 10,000 (68,950) Stroke Length in.(mm): 5 (127) Max. Speed rpm: 450 Max. plunger in.(mm): 4 (101.6) Max. piston in.(mm): 41/2 (114.3) Crankshaft extension: in.(mm) Diameter: 4 1/8 (104.78) Length: 8 1/8 (206.38) Keyway (width x depth): 1 x 1/2 (25.4 x 12.7) Pinion shaft extension, if gear unit supplied in.(mm) For Belt or chain drive: Diameter: 3 (76.2) Length: 6 3/16 (157.16) Keyway (width x depth): 3/4 x 3/8 (19.05 x 9.53) For direct drive: Diameter: 3 (76.2) Length: 6 3/16 (157.16) Keyway (width x depth): 3/4 x 3/8 (19.05 x 9.53) Accessory Gear Units: See accessories for reduction ratios. Oil Capacity: gallons (L) Crankcase: 8 (30) Gear unit - Varies with gear ratio: 2.25 to 3.5 (8.52 to 13.25) Weight, Pump only on wood shipping skids, pounds(Kg): 4000 (1814) Gear unit, approximate, pounds(Kg): 800 (363) Standard Equipment: Forged steel fluid end Forged steel valve covers Piston & liners or plungers & packing Slush type valves Oil level dipstick Crankcase breather Stainless steel extension rods Double extended crankshaft Accessories: Gear reduction units: 3.22:1, 3.46:1, 4.38:1, 4.96:1 Suction stabilizer Discharge dampener Liner flush system Plunger lubricator Valve seat puller assembly Complete unitization with electric motor or engine drive
JWS-185 Triplex Well Service Pump Performance Data Diameter, in. gal/min. per RPM bbl/min. per RPM Req’d. RPM hp 450 185 400 185 350 185 300 185 250 185 225 185 200 185 100 132 50 66 25 33
Plungers Only 2” .2040 .0049 gal/ bbl/ PSI min. min. 3110 92 2.19 3500 82 1.94 4000 71 1.70 4660 61 1.46 5600 51 1.21 6220 46 1.09 7000 41 0.97 10000 20 0.49 10000 10 0.24 10000 5 0.12
PSI 1644 1850 2110 2470 2960 3290 3700 5250 5250 5250
2 3/4” .3857 .0092 gal/ min. 174 154 135 116 96 87 77 39 19 10
bbl/ min. 4.13 3.67 3.21 2.75 2.30 2.07 1.84 0.92 0.46 0.23
PSI 1020 1140 1310 1520 1830 2030 2280 3240 3240 3240
3 1/2” .6247 .0149 gal/ min. 281 250 219 187 156 141 125 62 31 16
bbl/ min. 6.69 5.95 5.21 4.46 3.72 3.35 2.97 1.49 0.74 0.37
PSI 780 870 1000 1170 1400 1550 1750 2480 2480 2480
4” .8160 .0194 gal/ min. 367 326 286 245 204 184 163 82 41 20
bbl/ min. 8.74 7.77 6.80 5.83 4.86 4.37 3.89 1.94 0.97 0.49
Pistons Only 4 1/2” 1.0327 .0246 gal/ bbl/ PSI min. min.
1230 1380 1960 1960 1960
232 207 103 52 26
5.53 4.92 2.46 1.23 0.61
(Volumes indicated are displacement of incompressable fluid) The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
JWS-340 Triplex Well Service Pump Specifications
7/8 "x 7/16 KEYWAY 5 11/16 9 1/4
3.500 3.499
DIA.
11 1/8
4.875 DIA. 4.873
30 5/8
1 1/4 "x 5/8 " KEYWAY
36" SUCTION
7 1/2
27" DISCHARGE
7 1/2
55 1/2
13 1/8
13 1/8
6 7 1 1/8 " DIA. HOLE THRU
5 5/8
1 1/4 " x 5/8 " KEYWAY
SHAFT EXTENSION
4.875 4.873
16 3/4
48 3/4
1" STD. PIPE TAP
3 3/4
7 3/4
2" STD. PIPE TAP
19 3/4 40 3/4 67 1/4
Pump Model JWS-340
24 15/16 9 3/4
1 1/2 " STD. PIPE TAP
3 3/4
Flange Connections Discharge Connection Sizes Suction Connection Sizes 2 1/16 API 10,000# RJ 6 STD Pipe
13 1/16
6"
2 1/4
9"
12 1/4
7"
31 1/4
22 7/8
6 3/16
36 1/2
Pump size max. plunger dia. X stroke) in.(mm): 4 x 5 (102 x 127) Rated bhp at 450 rpm (kw): 340 (253.5) Maximum pressure: psi (kPa): 10,000(68,950) Stroke length in. (mm): 5 (127) Max. speed rpm: 450 Max. plunger in.(mm): 4 (101.6) Max. piston in.(mm): 4 1/2 (114.3) Crankshaft extension: in. (mm) Diameter: 4 7/8 (123.8) Length: 11 3/4 (298.0) Keyway (width x depth): 1 1/4 x 5/8 (32.0 x 16.0) Pinion shaft extension, if gear unit supplied in.(mm) For belt or chain drive: Diameter: 3 1/2 (88.9) Length: 5 11/16 (144) Keyway (width x depth): 7/8 x 7/16 (22.2 x 11.1) For direct drive: Diameter: 3 1/2 (88.9) Length: 5 11/16 (144) Keyway (width x depth): 7/8 x 7/16 (22.2 x 11.1) Accessory gear units: See accessories for reduction ratios Oil capacity: gallons(L) Crankcase: 6 (22.7) Gear Unit – Varies with gear ratio: 3.5 to 6.5 (13.2 to 24.6) Weight, pump only on wood shipping skids pounds (Kg): 5200 (2359) Gear unit, approximate pounds (Kg): 1100 (499) Standard Equipment Forged steel fluid end Forged steel valve covers Piston & liners or plungers & packing Slush type valves Oil level dipstick Crankcase breather Stainless steel extension rods Double extended crankshaft Accessories Gear Reducers 2.27:1, 2.89:1, 3.25:1, 4.38:1, 4.84:1, 5.63:1 Suction stabilizer Discharge dampener Liner flush system Plunger lubricator Valve seat puller assembly Complete unitization with electric motor or engine drive
JWS-340 Triplex Well Service Pump Performance Data Diameter, in. gal/min. per RPM bbl/min. per RPM Req’d. RPM hp 450 340 400 340 350 340 300 340 250 340 225 340 200 340 100 252 50 126 25 63
PSI 3020 3400 3890 4530 5440 6040 6800 10000 10000 10000
23/4” .3857 .0092 gal/ min. 174 154 135 116 96 87 77 39 19 10
bbl/ min. 4.13 3.67 3.21 2.75 2.30 2.07 1.84 .92 .46 .23
PSI 1870 2100 2400 2800 3360 3730 4200 6220 6220 6220
31/2” .6247 .0149 gal/ min. 281 250 219 187 156 141 125 62 31 16
bbl/ min. 6.69 5.95 5.21 4.46 3.72 3.35 2.97 1.49 .74 .37
PSI 1430 1610 1840 2140 2570 2860 3210 4760 4760 4760
4” .8160 .0194 gal/ min. 367 326 286 245 204 184 163 82 41 20
bbl/ min. 8.74 7.77 6.80 5.83 4.86 4.37 3.89 1.94 .97 .49
PSI 2260 2540 3760 3760 3760
Pistons Only 41/2” 1.0327 .0246 gal/ bbl/ min. min. 232 5.53 207 4.92 103 2.46 52 1.23 26 .61
(Volumes indicated are displacement of incompressable fluid) The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
W-350 Triplex Plunger Pump P.E. LUBRICATION 1" FNPT (BOTH SIDES)
DISCHARGE CONNECTION 2" - 1502 WECO OR 3" - 1502 WECO
2" NPT SUMP CONNECTION TYP 2 PLACES
ROTARY UNION 1/2" NPT
Pump Type Horizontal Reciprocating Power Pump. Positive Displacement with Single-Acting Plungers Maximum Input Horsepower: 350 Intermittent, 200 Continuous Stroke Length: 6 inches Maximum Rod Load: 80,000 Ibs. Approximate Weight: 4,500 Ibs. Pump Power End: Fabricated of High Strength Steel Gears: Helical External Gearbox Gear Ratio: 5.25:1 or 4.68:1 Rod Bearings: Shell Type Replaceable Main Bearings: Straight Roller Pinion Bearings: Tapered Roller Crankshaft: One Piece Forged Alloy Steel Connecting Rod: Cast Steel Crosshead Guide: Cast Iron Fluid End: Plunger Type Monoblock Design. Machined From High Strength Alloy Steel, Heat Treated and Ultrasonic Tested - Auto Plunger Diameter: 2 to 5 inches Discharge Outlet: 2-inch WECO® Union Suction Inlet: 4 or 6-inch Standard Pipe Valves and Seats: Hardened Steel, Replaceable Insert Power End Lubrication: 18 GPM Required, Optional Hydraulic Lubrication System w/ Sump Available Packing Lubrication: Optional Air Driven Air/Oil or Mechanical Oil Drip System Available
25.16
.69
20.28
H
3.75 TYP
31.72
1" NPT PIPE PLUG
BLIND FLANGE
1810 SERIES SPICER COMPANION FLANGE
55.88
A B C
16.00
D
PUMP ROTATION GEARBOX
E
28.87
ROTATION
WECO® is a registered trademark of FMC
13.25 F 4.66 G
1.63 2.38
VICTAULIC CONNECTION
2.50
TYP BOTH SIDES
1" NPT SUMP CONNECTION TYP BOTH SIDES 38.00
Pump Model
1.63
Flange Connections Discharge Connection Sizes Suction Connection Sizes 2 (50.8) 1502 Half Union 4 (101.6) Grooved Pipe 3 (76.2) 1502 (Optional) 6 (152.4) Optional
W-350
Specifications
Dimensions (Inches) FE Size
A
B
C
D
E
F
G
H
J
K
L
3 1/2 - 4
4 1/8
6 1/4
3 1/8
9 9/32
6 1/8
12 3/8
5 3/4
25 5/8
18 11/16
15 1/16
11
4 1/2 - 5
4 1/2
5 7/8
2 3/4
10 13/16
7
13 1/4
5 3/4
27
18 1/4
15 13/16
11 1/4
W-350 Triplex Plunger Pump Performance Data Displacement Plunger Factors* Diameter @ 100% V. E. U.S. Gal. per Rev. Inches GPR 5.00 1.530 4.50 1.239 4.00 0.979 3.50 0.750 3.00 0.551 2.75 0.463 2.50 0.382 2.25 0.310 2.00 0.245 Input Brake ** Power Horsepower Pinion RPM @ 5.25:1 Gear Ratio Pinion RPM @ 4.68:1 Gear Ratio
50 Flow @ 100% V. E. U.S. Gal. per Min. GPM 77 62 49 38 28 23 19 16 12
Max Press. @ Flow PSIG 4076 5033 6369 8314 11317 13468 16323 20115 25451
Pump Speed in Crankshaft Revolutions Per Minute (RPM) 100 200 300 Flow Max Flow Max Flow @ 100% V. E. Press. @ 100% V. E. Press. @ 100% V. E. U.S. Gal. @ Flow U.S. Gal. @ Flow U.S. Gal. per Min. per Min. per Min. GPM PSIG GPM PSIG GPM 153 3333 306 1666 459 124 4116 248 2058 372 98 5209 196 2604 294 75 6799 150 3399 225 55 9254 110 4627 165 46 11013 93 5507 139 38 13349 76 6674 115 31 16449 62 8224 93 25 20813 49 10406 74
Max Press. @ Flow PSIG 1111 1372 1736 2266 3085 3671 4450 5483 6938
450 Flow @ 100% V. E. U.S. Gal. per Min. GPM 689 558 441 338 248 208 172 140 110
214
350
350
350
350
263
525
1050
1575
2363
234
468
936
1404
2106
Max Press. @ Flow PSIG 741 915 1157 1500 2050 2450 2960 4600 4625
*V.E. = Volumetric Efficiency, ** BHP (Brake Horsepower) is based on 85% Mechanical Efficiency The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
JWS-400 Triplex Well Service Pump 1 1/2 " x 3/4 " KEYWAY
5.998 6.000
DIA.
Specifications SUCTION & DISCHARGE CONNECTIONS MAY BE MADE AT EITHER END
10 1/4 " (USABLE SHAFT EXT.)
40 3/4 DISCHARGE
48 SUCTION
14 3/8
79 11/16
14 3/8
20 3/4
39 27/32
20 3/4
8 6 1/2
4 7/8 6.000 5.998
DIA.
8
10 1/4 " (USABLE SHAFT EXT.)
1 1/2 " DIA. HOLE THRU 4 PLACES, AS SHOWN
1 1/2 " x 3/4 " KEYWAY DISCHARGE 3 1/16 API 10,000# R.J. DISCHARGE CENTERLINE 6"
8 1/2
16 5/16
13 5/8
1 1/4
1 1/2"NPT(1 EACH SIDE) 15 1/2
28 13/16
2 1/4
SUCTION CENTERLINE 61 7/8 1 3/4
15 1/8
SUCTION 6" ANSI 150# F.F. 51 5/8 66 1/8 89
1" NPT (POWER END OIL DRAIN)
Pump Model JWS-400
2" NPT (CRADLE DRAIN)
Flange Connections Discharge Connection Sizes Suction Connection Sizes 3 1/16 API 6 BX 10,000 PSI 6 ASA-150# RF
Pump size (max. liner dia. X stroke) in. (mm): 5 1/2 x 7 (139.7 x 177.8) Pump size (max. plunger dia. X stroke) in. (mm): 4 1/2 x 7 (114.3 x 177.8) Rated bhp at 286 rpm (kw): 400 (298) Maximum working pressure: psi (kPa): 10,000 (68,950) Stroke length, in. (mm): 7 (177.8) Max. speed rpm: 286 Max. plunger in.(mm): 4 1/2 (114.3) Max. piston in.(mm): 5 1/2 (139.7) Crankshaft extension: in. (mm) Diameter: 6 (152.4) Length: 10 1/4 (260.4) Keyway (width x depth): 1 1/2 x 3/4 (38.1 x 19.05) Pinion shaft extension, if chain drive supplied in. (mm) Diameter: 3.75 (95.25) Length: 6 (152.4) Keyway (width x depth): 7/8 x 7/16 (22.2 x 11.1) Accessory gear units: See accessories for reduction ratios Oil Capacity: gallons (L) Crankcase: 22 (83.3) Chaincase : 30 (113.5) Weight, pump with reducer pounds (Kg): 15,000 (6804) Standard Equipment Forged steel fluid end Forged steel valve covers Piston & liners or plungers & packing Slush type valves Oil level dipstick Crankcase breather Stainless steel extension rods Double extended crankshaft Accessories Chain reducer (4.667:1) Suction stabilizer Discharge dampener Liner flush system Plunger lubricator Valve seat puller assembly Complete unitization with electric motor or engine drive
JWS-400 Triplex Well Service Pump Performance Data Diameter, in. gal/min. per RPM bbl/min. per RPM Req’d. RPM hp 286 400 250 400 200 400 175 400 140 400 100 400 75 400 55 400 25 187
4” 1.142 .02719 gal/ PSI min. 1900 327 2175 286 2725 228 3100 200 3819 160 5445 114 7250 86 10,000 63 10,000 29
bbl/ min. 7.78 6.80 5.44 4.76 3.80 2.72 2.04 1.50 .68
PSI 1500 1715 2140 2435 3072 4280 5747 8000 8000
41/2” 1.446 .0344 gal/ min. 414 361 289 253 202 145 108 80 36
bbl/ min. 9.85 8.61 6.88 6.02 4.82 3.44 2.58 1.89 .86
Pistons Only 5” 1.785 .0425 gal/ bbl/ PSI min. min. 1217 510 12.1 1390 446 10.6 1741 357 8.5 1979 312 7.43 2483 250 5.95 3482 178 4.24 4636 134 3.19 6334 98 2.33 6400 45 1.07
Pistons Only 51/4” 1.968 .0469 gal/ bbl/ PSI min. min. 1102 563 13.4 1261 492 11.7 1579 394 9.38 1795 344 8.19 2249 276 6.57 3159 197 4.69 4205 148 3.52 5747 108 2.57 5804 49 1.17
PSI 1004 1149 1439 1635 2055 2878 3831 5216 5289
Pistons Only 51/2” 2.159 .0514 gal/ bbl/ min. min. 618 14.7 540 12.8 432 10.3 378 9.0 302 7.19 216 5.14 162 3.86 119 2.83 54 1.28
(Volumes indicated are displacement of incompressable fluid) The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
W-500 Triplex Plunger Pump ROTARY UNION 1/2" NPT
P.E. LUBRICATION 1" FNPT (BOTH SIDES)
DISCHARGE CONNECTION 2" - 1502 WECO OR 3" - 1502 WECO
2" NPT SUMP CONNECTION TYP 2 PLACES
Pump Type: Horizontal Reciprocating Power Pump. Positive Displacement with Single-Acting Plungers Maximum Input Horsepower: 500 Intermittent, 250 Continuous Stroke Length: 6 inches Maximum Rod Load: 100,000 Ibs. Approximate Weight: 5,000 Ibs. Pump Power End: Fabricated of High Strength Steel Gears: Helical, External Gearbox Gear Ratio: 4.68:1 Rod Bearings: Shell Type Replaceable Main Bearings: Straight Roller Pinion Bearings: Tapered Roller Crankshaft: One Piece Forged Alloy Steel Connecting Rod: Cast Steel Crosshead Guide: Cast Iron Fluid End: Plunger Type Monoblock Design. Machined From High Strength Alloy Steel, Heat Treated and Ultrasonic Tested Plunger Diameter: 2.25 to 5 inches Discharge Outlet: 2-inch WECO Type Union Suction Inlet: 4 or 6-inch Standard Pipe Valves and Seats: Hardened Steel, Replaceable Inserts Power End Lubrication: 18 GPM Required, Optional Hydraulic Lubrication System w/ Sump Available Packing Lubrication: Optional Air Driven Air/Oil or Mechanical Oil Drip System Available
25.16
.69
22.03
H
3.75 TYP
33.47
1" NPT PIPE PLUG
BLIND FLANGE
1810 SERIES SPICER COMPANION FLANGE
55.88
A B C
16.00
D
PUMP ROTATION GEARBOX
E
28.87
ROTATION
13.25 F 4.66 G
1.63
VICTAULIC CONNECTION
2.38
2.50
TYP BOTH SIDES 1" NPT SUMP CONNECTION TYP BOTH SIDES 38.00
Pump Model
1.63
Flange Connections Discharge Connection Sizes Suction Connection Sizes 2 (50.8) 1502 Half Union 4 (101.6) Grooved Pipe 3 (76.2) 1502 (Optional) 6 (152.4) Optional
W-500
Dimensions (Inches) FE Size
A
B
C
D
E
F
G
H
2 3/4 - 3
4 1/2
5 1/2
2 3/8
8 3/4
5 3/8
11 1/4
4 3/4
27 1/2
3 1/2 - 4
4 1/8
6 1/4
3 1/8
9 9/32
6 1/8
12 3/8
4 3/4
27 5/8
4 1/2 - 5
4 3/8
6
3 1/32
10 13/16
7
13 1/4
4 3/4
29
Specifications
W-500 Triplex Plunger Pump Performance Data Displacement Plunger Factors* Diameter @ 100% V. E. U.S. Gal. per Rev. Inches GPR 5.00 1.530 4.50 1.239 4.00 0.979 3.50 0.750 3.00 0.551 2.75 0.463 2.50 0.382 2.25 0.310 Input Brake** Power Horsepower Pinion RPM @4.68:1 Gear Ratio
50 Flow @ 100% V. E. U.S. Gal. per Min. GPM 77 62 49 38 28 23 19 16 267 234
Max Press. @ Flow PSIG 5085 6279 7947 10373 14120 16803 20366 25096
Pump Speed in Crankshaft Revolutions Per Minute (RPM) 100 200 300 Flow Max Flow Max Flow @ 100% V. E. Press. @ 100% V. E. Press. @ 100% V. E. U.S. Gal. @ Flow U.S. Gal. @ Flow U.S. Gal. per Min. per Min. per Min. GPM PSIG GPM PSIG GPM 153 4761 306 2381 459 124 5879 248 2940 372 98 7441 196 3720 294 75 9713 150 4856 225 55 13221 110 6610 165 46 15733 93 7867 139 38 19069 76 9535 115 31 23498 62 11749 93 500 500 500 468
936
1404
Max Press. @ Flow PSIG 1587 1960 2480 3238 4407 5244 6356 7833
450 Flow @ 100% V. E. U.S. Gal. per Min. GPM 689 558 441 338 248 208 172 140 500
Max Press. @ Flow PSIG 1058 1307 1654 2158 2900 3496 4238 5222
2106
*V.E. = Volumetric Efficiency **BHP (Brake Horsepower) is based on 85% Mechanical Efficiency The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
W-600S Plunger Pump Specifications Pump type: Intermittent duty reciprocating pump Maximum Input Horsepower: 600 Intermittent Stroke Length: 6 inches Maximum Rod Load: 100,000 lbs. Approximate Weight: 4,600 lbs. Pump Power End: Fabricated of high strength alloy steel Gears: Helical Gear Ratio: 4.6:1 Rod Bearings: Shell type replaceable Main Bearings: Straight roller Gearbox Bearings: Tapered roller Crankshaft: One-piece forged alloy steel nitrided Connecting Rod: Cast steel Crosshead: Cast steel Crosshead Slide: Shim adjustable, replaceable cast iron Fluid-End: Plunger type mono-block design Discharge: 2 inch half union forged steel female connection – both ends Suction: Fabricated steel with 4” grooved connections – both ends Valves and Seats: Service Master™ II
53.70
33.14
50.46
1.50 6.88
23.82
12.00
11.00
2.50
32.32
Pump Model W600-S
Flange Connections Discharge Connection Sizes Suction Connection Sizes 2 (50.8) 1502 Half Union 4 (101.6) Grooved Pipe
W-600S Plunger Pump Performance Data Displacement Plunger Factors* Diameter @ 100% V. E. U.S. Gal. per Rev. Inches GPR 2.50 .3825 2.75 .4628 3.00 .5508 3.50 .7497 4.00 .9792 4.50 1.2393 Input Brake** Power Horsepower Pinion RPM @4.60:1 Gear Ratio
50 Flow @ 100% V. E. U.S. Gal. per Min. GPM 19.12 23.14 27.54 37.48 48.96 61.96 253 230
Max Press. @ Flow PSIG 20372 16836 14147 10394 7958 6288
Pump Speed in Crankshaft Revolutions Per Minute (RPM) 120 200 300 Flow Max Flow Max Flow @ 100% V. E. Press. @ 100% V. E. Press. @ 100% V. E. U.S. Gal. @ Flow U.S. Gal. @ Flow U.S. Gal. per Min. per Min. per Min. GPM PSIG GPM PSIG GPM 45.90 20165 76.50 12099 114.75 55.54 16665 92.56 9999 138.85 66.10 14003 110.16 8402 165.24 89.96 10288 149.94 6173 224.91 117.50 7877 195.84 4726 293.76 148.72 6224 247.86 3734 371.79 600 600 600 552
920
1380
Max Press. @ Flow PSIG 8066 6666 5601 4115 3151 2489
450 Flow @ 100% V. E. U.S. Gal. per Min. GPM 172.12 208.27 247.86 337.36 440.64 557.68 600
Max Press. @ Flow PSIG 5377 4444 3734 2744 2100 1660
2070
*V.E. = Volumetric Efficiency **BHP (Brake Horsepower) is based on 90% Mechanical Efficiency The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
W-1300 Triplex Plunger Pump Specifications
DISCHARGE CONNECTION MAY BE MOUNTED ON EITHER SIDE OF PUMP
7.50
22.69
52.63
37.63
66.11
BLIND FLANGE 1/4 NPT LUBRICATION CONN. FOR STUFFING BOX
6.82
7.26
ÿ4.00 PINION KEYWAY IS 1.0 WIDE x .5 DP
40.38
B
C
34.51
A
22.50 19.06
D
E 44.42
Pump Type: Horizontal Reciprocating Power Pump Positive Displacement with Single-Acting Plungers Maximum Input Horsepower: 1,300 Intermittent, 650 Continuous Stroke Length: 8 inches Maximum Rod Load: 200,000 Ibs. Approximate Weight: 11,000 Ibs. Pump Power End: Fabricated of High Strength Steel Gears: Double Helical Gear Ratio: 7.0:1 or 7.5:1 Rod Bearings: Shell Type Replaceable Main Bearings: Straight Roller Pinion Bearings: Spherical Roller Crankshaft: One Piece Forged Alloy Steel Connecting Rod: One Piece Forged Steel with Knuckle Joint Crosshead Guide: Bronze Replaceable Fluid End: Plunger Type Monoblock Design. Machined From High Strength Alloy Steel, Heat Treated and Ultrasonic Tested Autofrettaged* Plunger Diameter: 3.75 to 7.5 inches Discharge Outlet: 2 or 3-inch WECO® Union Suction Inlet: 6 or 8-inch Diameter Valves and Seats: Hardened Steel, Replaceable Insert Power End Lubrication: 35 GPM Required, Optional Hydraulic Lubrication System w/ Removable Bolt on Sump Packing Lubrication: Optional Air Driven Air/Oil or Mechanical Oil Drip System Available
11.00 F
WECO® is a registered trademark of FMC *Autofrettaged Fluid Ends available for 5 3/4˝ & smaller Plungers 11.81 G
17.50
8.50
1" NPT CONNECTION
55.50
89.88
Pump Model W-1300
Flange Connections Discharge Connection Sizes Suction Connection Sizes 2 (50.8) 1502 Half Union 4 (101.6) Grooved Pipe 3 (76.2) 1502 (Optional) 6 (152.4) Optional
Dimensions (Inches) FE Size
A
B
C
D
E
F
G
4
24 3/4
8 1/8
3 1/4
11 9/64
7 1/8
14 1/16
8 3/4
4 1/2
24 3/4
8 1/8
3 1/2
11 9/64
7 1/8
14 1/16
8 3/4
5
24 3/4
8 1/8
3 1/2
11 9/64
7 1/8
14 1/16
8 3/4
5 1/2
24 3/4
7 1/8
3
11 1/2
7 5/8
15 3/16
7 5/8
5 3/4
24 3/4
7 1/8
3
11 1/2
7 5/8
15 3/16
7 5/8
6 1/2
25
7 1/8
4
11 1/2
8 1/2
15 11/16
7 1/8
6 3/4
25
7 1/8
4
11 1/2
8 1/2
15 11/16
7 1/8
W-1300 Triplex Plunger Pump Performance Data Displacement Plunger Factors* Diameter @ 100% V. E. U.S. Gal. per Rev. Inches GPR 7.50 4.590 7.00 3.999 6.75 3.713 6.50 3.448 6.00 2.938 5.75 2.698 5.50 2.468 5.00 2.040 4.50 1.652 4.00 1.306 3.75 1.147 Input Brake** Power Horsepower Pinion RPM @7.50:1 Gear Ratio Pinion RPM @ 7.00:1 Gear Ratio
100 Flow @ 100% V. E. U.S. Gal. per Min. GPM 459 400 371 345 294 270 247 204 165 131 115
Max Press. @ Flow PSIG 4126 4736 5101 5493 6446 7020 7670 9284 11465 14502 16512 ***
Pump Speed in Crankshaft Revolutions Per Minute (RPM) 150 200 250 Flow Max Flow Max Flow Max @ 100% V. E. Press. @ 100% V. E. Press. @ 100% V. E. Press. U.S. Gal. @ Flow U.S. Gal. @ Flow U.S. Gal. @ Flow per Min. per Min. per Min. GPM PSIG GPM PSIG GPM PSIG 689 2715 918 2063 1148 1651 600 3157 800 2368 1000 1849 557 3401 743 2550 928 2040 517 3662 690 2746 862 2197 441 4298 588 3223 735 2579 405 4680 540 3510 675 2808 370 5120 494 3830 617 3070 306 6189 408 4642 510 3714 248 7643 330 5732 413 4586 196 9668 261 7251 327 5801 172 11008 229 8256 287 6605
330 Flow @ 100% V. E. U.S. Gal. per Min. GPM 1515 1320 1225 1138 970 890 814 673 545 431 379
1300
1300
1300
1300
1300
750
1125
1500
1875
2475
700
1050
1400
1750
2310
Max Press. @ Flow PSIG 1250 1435 1546 1665 1953 2127 2330 2813 3474 4395 5004
* V.E. = VOLUMETRIC EFFICIENCY, **BHP (Brake Horsepower) is based on 85% Mechanical Efficiency *** Applications at pressures above 15,000 PSIG must be approved by “OMEGA” Engineering Department The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)
W-2250 Triplex Plunger Pump Specifications
DISCHARGE CONNECTION MAY BE MOUNTED ON EITHER SIDE OF PUMP
7.50
22.69
52.63
37.63
65.60
BLIND FLANGE 1/4 NPT LUBRICATION CONN. FOR STUFFING BOX
6.75
6.06
29 TOOTH EXTERNAL
40.38
SPLINE, ÿ3.750
B
C
34.51
A
22.50 19.06
D
E 44.42 11.00 F
11.81 G
17.50
8.50
1" NPT CONNECTION
55.50
89.88
Pump Model W-2250
Flange Connections Discharge Connection Sizes Suction Connection Sizes 2 (50.8) 1502 Half Union 4 (101.6) Grooved Pipe 3 (76.2) 1502 (Optional) 6 (152.4) Optional
Dimensions (Inches) FE Size
A
B
C
D
E
F
G
4
24 3/4
8 1/8
3 1/4
11 9/64
7 1/8
14 1/16
8 3/4
4 1/2
24 3/4
8 1/8
3 1/2
11 9/64
7 1/8
14 1/16
8 3/4
5
24 3/4
8 1/8
3 1/2
11 9/64
7 1/8
14 1/16
8 3/4
5 1/2
24 3/4
7 1/8
3
11 1/2
7 5/8
15 3/16
7 5/8
5 3/4
24 3/4
7 1/8
3
11 1/2
7 5/8
15 3/16
7 5/8
6 1/2
25
7 7/8
4
11 1/2
8 1/2
15 11/16
7 1/8
6 3/4
25
7 7/8
4
11 1/2
8 1/2
15 11/16
7 1/8
Pump Type: Intermittent duty reciprocating pump Maximum Input Horsepower: 2250 Intermittent Stroke Length: 8 inches Maximum Rod Load: 250,000 lbs. Approximate Weight: 11,500 lbs. Pump Power End: Fabricated of high-strength alloy steel Gears: Helical Gear Ratio: 6.35:1 Rod Bearings: Shell type replaceable Main Bearings: Straight roller Pinion Bearings: Spherical roller Crankshaft: Alloy steel nitrided Connecting Rod: One piece forged steel Crosshead: Cast steel Crosshead Guide: Bronze replaceable Fluid-End: Plunger type mono-block design Discharge Connection: 2 or 3 inch half union forged steel female connection – both ends Suction: 6 or 8 inch pipe w/ grooved connection Valves and Seats: Service Master™ II
W-2250 Triplex Plunger Pump Performance Data Displacement Plunger Factors* Diameter @ 100% V. E. U.S. Gal. per Rev. Inches GPR 7.50 4.590 7.00 3.998 6.75 3.718 6.50 3.448 6.00 2.938 5.75 2.698 5.50 2.468 5.00 2.040 4.50 1.652 4.00 1.306 Input Brake** Power Horsepower Pinion RPM @ 6.35:1 Gear Ratio
100 Flow @ 100% V. E. U.S. Gal. per Min. GPM 459 400 372 345 294 270 247 204 165 131
Max Press. @ Flow PSIG 5659 6496 6986 7534 8842 9628 10523 12732 15719 19894
Pump Speed in Crankshaft Revolutions Per Minute (RPM) 150 200 250 Flow Max Flow Max Flow @ 100% V. E. Press. @ 100% V. E. Press. @ 100% V. E. U.S. Gal. @ Flow U.S. Gal. @ Flow U.S. Gal. per Min. per Min. per Min. GPM PSIG GPM PSIG GPM 688 4761 918 3571 1147 600 5466 800 4099 1000 558 5878 744 4408 929 517 6339 690 4754 862 441 7439 588 5908 734 405 8100 540 6075 674 370 8853 494 6640 617 306 10713 408 8034 510 248 13225 330 9919 413 196 16738 261 12554 326
330 Max Press. @ Flow PSIG 2857 3279 3527 3803 4464 4860 5312 6428 7935 10043
Flow @ 100% V. E. U.S. Gal. per Min. GPM 1515 1319 1227 1138 969 890 815 673 545 431
1783
2250
2250
2250
2250
635
953
1270
1588
2096
Max Press. @ Flow PSIG 2164 2484 2672 2881 3381 3682 4024 4869 6012 7608
* V.E. = VOLUMETRIC EFFICIENCY, **BHP (Brake Horsepower) is based on 85% Mechanical Efficiency The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that stipulated in National Oilwell Standard Terms and Conditions of Sale.
Authorized Distributor:
www.natoil.com /
[email protected] 10000 Richmond, Houston, Texas 77042 (713)346-7500 (phone) • (713)346-7366 (fax)