PROTOCOLO DE ANALISIS DIMENSIONAL

CEMPRO TECH S.A.C.

MOLINO ALLIS CHALMERS A BOLAS 9' x 16'

CONTRUCTION, ENGINEERING, MANAGEMENT, PROCURE

CLIENTE : COMPAÑIA MINERA VOLCAN S.A.A

PAGINA: 07

PROYECTO: AMPLIACION PLANTA VICTORIA 4000 TND

FECHA : 08/01/2008

JUEGO AXIAL Y LATERAL DE LOS COJINETES PRINCIPALES

ITEM A1 A2 A3 A4 ITEM B1 B2 B3 B4

LADO CARGA JUEGO AXIAL DIFER.

5 mm 5 mm 13 mm 13 mm JUEGO LAT.

TOLER. ACEPT.

0.00

0.15

0.00

0.15

TOLER.

ACEPT. OK OK OK OK

0.5 x 8 inch1.5 0.35 x 8 inch1.5 0.20 x 8 inch1.5 0.30 x 8 inch1.5

x x x x

8 8 8 8

inch inch inch inch

OK

ITEM A1 A2 A3

OK

A4 ITEM B1 B2 B3 B4

LADO DESCARGA JUEGO AXIAL DIFER. TOLER. ACEPT.

0.22 0.00 0.30 0.46 JUEGO LAT.

0.20 0.18 0.33 0.43

x x x x

8 8 8 8

0.11

0.15

0.08

0.15

TOLER.

ACEPT. OK OK OK OK

inch1.5 inch1.5 inch1.5 inch1.5

x x x x

8 8 8 8

inch inch inch inch

OK

OK

OBSERVACIONES : Tolerancias tomadas de manual de Molinos Allise Chalmers 1.- Juego lateral: Para un diametro de 40 inch, 0.06 inch @ 8 inch ( 1.5 mm @ 203.2 ) 2.- Juego axial : 0.15 mm HERRAMIENTAS UTILIZADAS PARA EL CONTROL : 1.- Gauje de lámina 14". 2.- Calibrador Digital 6" 3.- Flexómetro 3mts

CONTROL DE CALIDAD

CEMPROTECH

SUPERVISION

GMI

CEMPRO TECH S.A.C. PROTOCOLO DE ANALISIS DIMENSIONAL MOLINO ALLIS CHALMERS A BOLAS 9' x 16' CONTRUCTION, ENGINEERING, MANAGEMENT, PROCURE PAGINA: 08

CLIENTE : COMPAÑIA MINERA VOLCAN S.A.A

PROYECTO: AMPLIACION PLANTA VICTORIA 4000 TNDFECHA : 8/01/08

RONOUT UNION DE CATALINA

LADO CARGA ESTACION Nº 1

LADO DESCARGA 0.05

CONTROL DE CALIDAD

CEMPROTECH

ESTACION Nº 7

SUPERVISION

GMI

0.10

CEMPRO TECH S.A.C.

MOLINO ALLIS CHALMERS A BOLAS 9' x 16'

PROTOCOLO DE ANALISIS DIMENSIONAL CLIENTE : COMPAÑÍA MINERA VOLCAN S.A.A. PAGINA: 12 FECHA : 03 / 11 / 2007 PROYECTO: AMPLIACION PLANTA VICTORIA 4000 TND CONTRUCTION, ENGINEERING, MANAGEMENT, PROCURE

ALINEAMIENTO DE RODAMIENTO CON CHUMACERA

LADO FIJO A B C D

0.00 0.05 0.00 0.05

LADO FLOTANTE

A B C D

3.50 6.40 3.60 6.40

OBSERVACION:

CONTROL DE CALIDAD

CEMPROTECH

SUPERVISOR GMI

CEMPRO TECH S.A.C. CONTRUCTION, ENGINEERING, MANAGEMENT, PROCURE

PROTOCOLO DE ANALISIS DIMENSIONAL MOLINO MARCY DE BARRAS 10.5' x 17'

CLIENTE : VOLCAN COMPAÑÍA MINERA S.A.A

PAGINA: 13 PROYECTO: AMPLIACION PLANTA VICTORIA 4000 TND FECHA :04 /11 /2007

REGISTRO DE CONTACTO, BACKLASH Y LUZ DE LA RAIZ

ESTACIÓN

3 6 9 12

CONTACTO

BACKLASH

LADO CARGA LADO DESCARGA LADO CARGALADO 0.00 0.20 2.60 0.00 0.10 2.90 0.00 0.20 2.40 0.00 0.00 2.40

LUZ DE RAIZ

DESCARGA LADO CARGA LADO DESCARGA 2.50 11.40 11.60 2.60 11.80 11.50 3.00 11.90 11.50 2.00 11.00 11.80

OBSERVACIONES:

CONTROL DE CALIDAD

CEMPROTECH

SUPERVISOR GMI

View more...