Project Report on Gear Pump
January 27, 2017 | Author: Sunil Kumar Yadav | Category: N/A
Short Description
Download Project Report on Gear Pump...
Description
Galgotias College of Engineering and Technology Department of Mechanical Engineering
Project report on To design, fabrication & testing of gear pump test rig
By 1.SUNIL KUMAR YADAV (0809740092) 2.SHRI BALLABH GOSWAMI (0809740087) 3.VIVEK CHANDRA PANDEY ( 0809740099) 4.SAURABH SINGH ( 0809740082 )
in partial fulfillment of Degree Requirements as per UPTU Syllabus for the award of
Bachelor of Technology (Mechanical Engineering)
Batch of 2008-12
Galgotias College of Engineering and Technology Department of Mechanical Engineering
CERTIFICATE This is to certify that the project entitled “To design, fabrication & testing of gear pump test rig” submitted by Sunil Kumar Yadav (0809740092), Shri Ballabh Goswami (0809740087), Vivek Chandra Pandey (0809740099), Saurabh Singh ( 0809740082 ) to the Department of Mechanical Engineering, Galgotias College of Engineering and Technology, Gr. Noida, in partial fulfillment of Degree Requirements as per GBTU Syllabus for the award of Bachelor of Technology (Mechanical Engineering), is a record of bonafide work carried out by them. They have worked under my guidance and supervision.
Prof. Dr. M. N. Desmukh Sudip Ghatak
Prof.
Deptt. of Mechanical Engineering Engineering Galgotia College of Engg. & Tech. Engg. & Tech
Deptt. of Mechanical Galgotia College of
Table of content 1.Project overview 2.Literature review of project 3.Technical detail 4.Calculation for gear pump dimension 5.Reference
1- The overview of project A gear pump uses the meshing of gears to pump fluid by displacement.They are one of the most common types of pumps for hydraulic fluid power applications. Gear pumps are also widely used in chemical installations to pump fluid with a certain viscosity. There are two main variations; external gear pumps which use two external spur gears, and internal gear pumps which use an external and an internal spur gear. Gear pumps are positive displacement (or fixed displacement), meaning they pump a constant amount of fluid for each revolution. Some gear pumps are designed to function as either a motor or a pump.
Theory of operation As the gears rotate they separate on the intake side of the pump, creating a void and suction which is filled by fluid. The fluid is carried by the gears to the discharge side of the pump, where the meshing of the gears displaces the fluid. The mechanical clearances are small— in the order of 10 μm. The tight clearances, along with the speed of rotation, effectively prevent the fluid from leaking backwards. The rigid design of the gears and houses allow for very high pressures and the ability to pump highly viscous fluids.
Many variations exist, including; helical and herringbone gear sets (instead of spur gears), lobe shaped rotors similar to Roots Blowers (commonly used as superchargers), and mechanical designs that allow the stacking of pumps.
•
External gear pump design for hydraulic power applications.
• Internal gear (Gerotor) pump design for automotive oil pumps
1- Literature Review of Project External gear pumps are a popular pumping principle and are often used as lubrication pumps in machine tools, in fluid power transfer units, and as oil pumps in engines. External gear pumps can come in single or double (two sets of gears) pump configurations with spur (shown), helical, and herringbone gears. Helical and
herringbone gears typically offer a smoother flow than spur gears, although all gear types are relatively smooth. Large-capacity external gear pumps typically use helical or herringbone gears. Small external gear pumps usually operate at 1750 or 3450 rpm and larger models operate at speeds up to 640 rpm. External gear pumps have close tolerances and shaft support on both sides of the gears. This allows them to run to pressures beyond 3,000 PSI / 200 BAR, making them well suited for use in hydraulics. With four bearings in the liquid and tight tolerances, they are not well suited to handling abrasive or extreme high temperature applications. Tighter internal clearances provide for a more reliable measure of liquid passing through a pump and for greater flow control. Because of this, external gear pumps are popular for precise transfer and metering applications involving polymers, fuels, and chemical additives.
How External Gear Pumps Work External gear pumps are similar in pumping action to internal gear pumps in that two gears come into and out of mesh to produce flow. However, the external gear pump uses two identical gears rotating against each other -- one gear is driven by a motor and it in turn drives the other gear. Each gear is supported by a shaft with bearings on both sides of the gear. 1. As the gears come out of mesh, they create expanding volume on the inlet side of the pump. Liquid
flows into the cavity and is trapped by the gear teeth as they rotate. 2. Liquid travels around the interior of the casing in the pockets between the teeth and the casing -- it does not pass between the gears. 3. Finally, the meshing of the gears forces liquid through the outlet port under pressure. Because the gears are supported on both sides, external gear pumps are quiet-running and are routinely used for high-pressure applications such as hydraulic applications. With no overhung bearing loads, the rotor shaft can't deflect and cause premature wear
2- Technical detail Gear Dimensions
Emprical formula for discharge calculation :-
Ideal discharge Q= 2aln.N/60 Where a= the area enclosed b/w two adjacent teeth & casing l = axial length of teeth
n = number of teeth in each pinion N = speed in rpm
Parametric curve
Equations of an involute curve for a parametrically defined function ( x(t) , y(t) ) are:
In Cartesian coordinates the involute of a circle has the parametric equation:
where a is the radius of the circle and t is a parameter
In polar coordinates the involute of a circle has the parametric equation:
where a is the radius of the circle and
is a
parameter
2nd emperical formula :
Q = 0.95πC(D – C )lN
where C = the centre to centre distance b/w axis of gears D = outside diameter of gears l = axial length of teeth N = speed in rpm
Outside Diameter ( D):D = d + 2/Pd where d = pitch diameter Pd = Diameterical pitch
Diameterical pitch ( Pd ):Pd = n/d where n = no of teeth d = pitch diameter
Minimum no of teeth to avoid interence :-
where n = number of teeth x = pressure angle
4-Calculation for gear pump dimension :• for x = 14.5 n = 23
for x = 20 n = 13
for x = 25
n=9 For x = 30
n=7
Table for D/C & n
D/C
n
1.28 1.21 1.13 1.12 7 10 13 18
For x= 20• , n=13, d=20 mm, l=30, D= 23.0769 mm, C= 20.422 mm N = 1500 rpm Q = 7.278 lpm
for n=13, d= 25 mm l= 37.5 mm, D= 28.84 mm, C= 25.527mm
N = 1500 rpm Q = 14.22 lpm
For n =14 , d= 20 mm , l= 30 mm, D= 22.85 mm, C= 20.26 mm N= 1500 rpm Q = 7.056 lpm
for n= 15, d =20 mm l= 30 mm, D = 22.666 mm, C= 20.13 mm N = 1500 rpm Q = 6.85 lpm
For x=30•, n= 7,
d=31.11 mm,
l= 31 mm, D= 40.00 mm, C= 31.25 mm N = 1500 rpm Q = 38.08 lpm
For x= 30•, n= 7, d= 35 mm
l= 35 mm, D= 45 mm, C= 35.15 mm, N = 1500 rpm Q = 54.24 lpm Calculation for gear dimension:X= 30•, n= 7, d= 35 l= d l= 35 mm, Pd = n/d Pd = 7/35 Pd = 0.2, Outside dia D = d + 2/Pd D = 35 + 2/0.2 = 45 mm For n=7, D/C = 1.28, Then C = 35.15 mm, N= 1500 rpm Then discharge Q = 0.95*π*C(D-C)lN Then
Q = 54.24 lpm
Design of casing :
Casing is like cylinder . Since in gear pump pressure is relatively high nearly 200 bar . So we design a thick casing for gear pump
thickness of casing ( t ):-
Take factor of safety = 3 for grey cast iron ( FG 200) Sut= 200 MPa Di= 40 mm Pi = 20 Mpa permissible tensile strength = 66.666 Mpa then thickness t = 7.25 mm
if fos is = 4 then
t = 10.55 mm
For malleable cast iron
Sut= 400 Mpa Di = 40 mm Pi = 20 Mpa
if f.o.s. = 3, t = 3.26 mm
if f.o.s. = 4, t = 4.49 mm
Gear pump parameter Parameter
Value
variable
How to get it
No. of teeth
7
n
We choose
Pitch
0.2
p
n/ PD
30
x
Usually
(diameterial) Pressure angle
standard (14.5, 20,25, 30)
Addendum
45
AD
PD + 2*a
22.5
DD
PD – 2*d
Pitch dia
35
PD
WE CHOOSE
Addendum
5
a
1/p
Dedendum
6.25
d
1.25/p
dia Dedendum dia
Design of shaft Pout = (ps – pd )*Q = Pin - Ploss Take ps – pd = 25 bar Q = 54.24 lpm = 9.04 * 10-4 m3/s
Then
Pout = 2.251 kw
Generally efficiency of gear pump is 85% So Pin = 2.251/0.85 =2.648 kw N = 1440 rpm T = 60*106*Pin/( 2*π*N ) Then
T = 17560.095 N-mm
The permissible shear stress :-
For alloy steel , 50C4 Syt = 460 MPa
,
Sut = 660 MPa
Permissible shear strength = minimum of ( 0.3*460 = 138 MPa & 0.18*660 = 118.8 MPa ) So permissible shear strength = 118.8 MPa
Then d3 = 1003.725 mm d= 10.012 mm d= 10 mm
References :Hydraulic machines by Dr. Jagdish Lal published by Metropolitan Book Co. Private Ltd. • www.wikipedia.com • Theory of machine by S.S. Rattan published by T.M.H • Design of Machine Element by Dr. V.B. Bhandari published by McGraw Hill. •
View more...
Comments