Download Pressure Testing and Purging Calculator (1)...
Description
Printed: 11/27/2012
Volume of Nitrogen Required For Testing & Purging Containers ** Insert Pertinent Information In Yellow Boxes
Pressure Testing PIPE with Nitrogen 131
Length In Ft. =
23
Dia. In Inches. = =L =D
Dia. In Ft. =
Nitrogen Volume Required
Volume of Gas @
58
PSIG:
1,868
1.917
High Pressure 'T' Cylinders Required
T Cyl.s 6.3
CF
The Nitrogen volumes shown are for pressurizing a pipe to the selected pressure only. Additional Nitrogen would be required for any additional purging or volume changes. See below for purging calculations. It is always recommended to have additional Nitrogen available to compensate for any leaks or un-foreseen requirements.
Purging or Pressure Testing TANKS with Nitrogen 131
Length or Height In Ft. = =L
=D
Nitrogen Volume Required 371 CF
Volume of Gas @ 1 Atm. To Obtain:
Purging Data
Diameter In Ft. =
Volume Required for Air Purge @ 1 Atm: Volume Required for Food Purge @ 1 Atm.: Volume Required for 100 % Purge @ 1 Atm.:
Purging does not require pressurization. The results shown are for the number of 'T' cylinders to provide the appropriate number of volume changes at very low flow with no pressurization. Note: NEVER enter a vessel that has been purged with Nitrogen, or any other gas unless you have tested that atmosphere for proper levels of oxygen.
For Pressure Test of Vessel, Add Test Pressure Required. Volume of Gas @
Pressure Testing Data
25
PSIG:
1,003
CF
High Pressure Cylinders Required
T Cyl.s 3.3
www.weldspecialty.com
Page 1 of 2
Printed: 11/27/2012
Volume of Nitrogen Required For Testing & Purging Containers ** Insert Pertinent Information In Yellow Boxes
Purging or Pressure Testing FURNACES with Nitrogen
12
Length In Ft. =
5
Width In Ft. =
6
Nitrogen Volume Required 360 CF
Volume of Gas @ 1 Atm. To Obtain:
Purging Data
Height In Ft. =
1,080 2,520 1,800
Volume Required for Air Purge @ 1 Atm: Volume Required for Food Purge @ 1 Atm.: Volume Required for 100 % Purge @ 1 Atm.:
Purging does not require pressurization. The results shown are for the number of 'T' cylinders to provide the appropriate number of volume changes at very low flow with no pressurization. Note: NEVER enter a vessel that has been purged with Nitrogen, or any other gas unless you have tested that atmosphere for proper levels of oxygen.
For Pressure Test of Vessel, Add Test Pressure Required. Volume of Gas @
50
Pressure Testing Data
PSIG:
1,584
CF
High Pressure Cylinders Required
T Cyl.s 5.3
** This information is used to determine volumes of N2 requirements for purging pipelines and vessels, and is not intended to replace proper monitoring of oxygen levels with proper equipment.
WELD Specialty Supply now has 3 locations to serve you better! 8929 N. 107th St. Milwaukee, WI 53224 (414) 354-2600
2047 Progress Way Kaukauna, WI 54130 (920) 759-0800
www.weldspecialty.com
N 6446 Rolling Meadow Drive Fond du Lac, WI 54937 (920) 922-9600
Thank you for interesting in our services. We are a non-profit group that run this website to share documents. We need your help to maintenance this website.