Pp02_ Asep_ Nscp 2015 Update on Ch1 General Requirements

February 2, 2018 | Author: Carlo Joseph | Category: Seismology, Business
Share Embed Donate


Short Description

General Requirements...

Description

REVISIONS IN   THE NATIONAL STRUCTURAL CODE  OF THE PHILIPPINES 2015, 7TH EDITION  CHAPTER 1 : GENERAL REQUIREMENTS

Chapter I : GENERAL REQUIREMENTS 

Under this Chapter, the following Sections were  updated and revised:

Section 102 : Definition of Failure Section 103 : Classification of Structures Section 104 : Design Requirements Section 105 : Posting and Instrumentation Inclusion of Appendix 1‐A and Appendix 1‐B

Section 102 : Definitions 

The 2015 National Structural Code of the Philippines,  Volume 1, 7th Edition, includes and elaborate the  meaning of “FAILURE”.

As defined, FAILURE is an unacceptable difference  between expected and observed performance. It  includes catastrophic structural collapse, but also  INCLUDES performance problems that are not  necessarily catastrophic or life‐threatening, including “”serviceability problems such as distress, excessive  deformation, premature deterioration of materials,  leaking roofs and facades, and inadequate interior  environmental control systems”.

Section 102 : Definitions In the event of a significant failure, the parties  typically retain experts to determine the cause of  the perceived failure. Occasionally a failure results from a single condition,  but typically, failures result from a combination of  mistakes, oversights, miscommunications,  misunderstandings, ignorance, lapses, slips,  incompetence, intentional violations or non‐ compliance, and inadequate quality assurance.

Section 102 : Definitions The causes for these conditions vary, but may include  simple mistakes (such as sending information to a  structural engineer when it should have been sent to the  architect), conclusions based on faulty assumptions, an  employee’s “laziness, ignorance, or malevolent urge,”  fatigue from excessive workload, inadequate training,  “time boxing” practices used to minimize fees to a  client, overreliance on computer‐aided design and  drafting (CADD), failure to understand and deliver client  requirements, time pressures to a deliver a project by  certain deadlines, and ineffective coordination and  integration of the design team. 

Section 103 : Classification of Structures The single‐story school building which is under the Special  Occupancy Structures Occupancy Category of the National  Structural Code of the Philippines 2010, 6th Edition is deleted. The National Structural Code of the Philippines 2015, 7th Edition categorized that all public school buildings are  included in the Essential Facilities Occupancy Category.   Churches, mosques and other related religious structures are  classified as Special Occupancy Structures Category

Section 104 : Design Requirements National Structural Code of the Philippines 2010,  6th Edition

National Structural Code of the Philippines  2015, 7th Edition

Section 104.4 Foundation Investigation

Section 104.4 Foundation Investigation

Soil explorations shall be required for  buildings, towers and other vertical  structures falling under Categories I, II and  III in accordance with Table 103‐1 or as  required by the Building Official of if the  site specific conditions make the  foundation investigation necessary.

Soil explorations shall be required for  buildings, towers and other vertical  structures falling under Categories I, II, III  and IV in accordance with Table 103‐1 or as  required by the Building Official of if the  site specific conditions make the  foundation investigation necessary.

Detailed requirements for foundation  investigations shall be in accordance with  Chapter 3 of this code.

Detailed requirements for foundation  investigations shall be in accordance with  Chapter 3 of this code.

Section 105 : Posting and Instrumentation National Structural Code of the  Philippines 2010, 6th Edition

National Structural Code of the  Philippines 2015, 7th Edition

Section 105.2.1 General Unless waived by the building  official, every building in  Seismic Zone 4 or over 50m in  height shall be provided with  not less than three approved  recording accelerographs. The  accelerographs shall be  interconnected for common  and start and common timing.

Section 105.2.1 General Unless waived by the building  official, every building in Seismic  Zone 4 or over 50m in height shall  be provided with not less than three  approved Earthquake Recording  Instruments (ERI). The ERI shall be  interconnected for common and  start and common timing.  Refer to “ASEP Guidelines and  Implementing Rules on Earthquake  Recording Instrumentation for  Buildings (Appendix 1‐B)

Section 105 : Posting and Instrumentation National Structural Code of the  Philippines 2010, 6th Edition

National Structural Code of the  Philippines 2015, 7th Edition

Section 105.2.3 Maintenance Maintenance and service of the  instruments shall be provided by  the owner of the building,  subject to the monitoring of the  Building Official. Data produced  by the instruments shall be  made available to the Building  Official or the Philippine  Institute of Volcanology and  Seismology (PHIVOLCS) on  request.

Section 105.2.3 Maintenance Maintenance and service of  the instruments shall be  provided by the owner of the  building, subject to the  monitoring of the Building  Official. Data produced by the  instruments shall be made  available to the Building  Official or any authorized  agency upon request.

Section 105 : Posting and Instrumentation National Structural Code of the Philippines  2010, 6th Edition

National Structural Code of the  Philippines 2015, 7th Edition

Section 105.2.4 Instrumentation of Selected  Buildings All owners of existing structures selected by  the authorities having jurisdiction shall  provide accessible space for the installation  of appropriate earthquake‐recording  instruments. Location of said instruments  shall be determined by PHIVOLCS or the  authorities having jurisdiction.  PHILVOLCS or the authorities having  jurisdiction shall make arrangements to  provide, maintain and service the  instruments. Data shall be the property of  the authorities having jurisdiction, but  copies of individual records shall be made  available to the owner of the building and to  the public on request and after the payment  of an appropriate fee.

Section 105.2.4  Instrumentation of Selected  Buildings All owners of existing  structures selected by the  authorities having jurisdiction  shall provide accessible space  for the installation of  appropriate earthquake‐ recording instruments,  determined by a Structural  Engineer.

Chapter 1 : GENERAL REQUIREMENTS UNDER THIS CHAPTER THE FOLLOWING GUIDELINES  ARE INCLUDED AS APPENDIX 1‐A AND APPENDIX 1‐B

APPENDIX 1‐A : Recommended Guidelines on  Structural Design Peer Review of Structures  2015 APPENDIX 1‐B : Guidelines and Implementing  Rules on Earthquake Recording  Instrumentation for Buildings

Chapter 1 : GENERAL REQUIREMENTS

THANK YOU  AND  HAVE A FRUITFUL SESSIONS AHEAD.