Power System, Rectifier
Short Description
Download Power System, Rectifier...
Description
Complete Network Power Products for Business-Critical Continuity™
2008 2009 Catalog ~ ~
6
2
8 3 5 11
2
7
7
1
9
4
9 4
5
6
2
8 3 5 11
2
7
7
1
9
4
9 4
5
Grid-to-chip protection for your critical investments investments No other organization can match the scope of Emerson Network Power’s product offerings and service reach, nor provide such complete grid-to-chip protection to ensure Business-Critical Business-Cri tical Continuity ™
for your technology investment.
Services Emerson Network Power supports these Centers of Expertise with the largest global services organiza organization tion in the industry, delivering:
1 2
2
–
Design, installation and startup
–
Warranty Warra nty service
–
Preventive maintenance
–
24x7 remote monitoring monitoring
–
Emergency service
–
Site audits
1 11
6
10
0
6 11
9
8
5 3
6
Contents
A Full Spectrum of Products of Emerson Network Power DC POWER
1
OUTSIDE PLANT
16
AC POWER
23
RACKS & INTEGRATED CABINETS
41
PRECISION COOLING
43
MONITORING
48
EMBEDDED POWER
54
EMERSON NETWORK POWER. THE GLOBAL LEADER IN ENABLING BUSINESS-CRITICAL CONTINUITY.™
AC POWER CONNECTIVITY DC POWER EMBEDDED COMPUTING EMBEDDED POWER
DC POWER MONITORING OUTSIDE PLANT POWER SWITCHING & CONTROLS PRECISION COOLING RACKS & INTEGRATED CABINETS SERVICES SURGE PROTECTION
Supporting voice and communications networks with dependable DC power solutions. We ’ve built on trusted names-lorain®,Actura and PS-to create NetSure™ DCPower Solutions ,the next-generation global technology platform that delivers the most rigorous network-power applications,with an unparalleled breadth DC power , distribution,control and monitoring systems.
DC Power. Yet another way Emerson Network Power enables Business-Critical Continuity™. 1
DC Power System
DC Power System Confi guration Matrix Large system
2
Medium System
Medium System
Small System
NetSure 801
P S486 00-3/2 900 -X5
PS48 250 -1 A/290 0
PS4 825 0-1B/2 900
Max. Power
348kW
34.8kW
14.5kW
14.5kW
14.5kW
9.6kW
Voltage
-48V
-48V
-48V
-48V
-48V
-48V
Max. Current
6000A
600A
250A
250A
250A
165A
Max. Number of Rectifiers
60
12
5
5
5
3
Rectifier Type
R48-5800
R48-2900
R48-2900
R48-2900
R48-2900
R48-3200,R48-2900
Controller Type
M810G
M500F
M501D
M501D
M501D
M501D
Dimension
Multi-cabinet system
600×600×2000
600×600×2000
600×400×2000
600×400×700
600×600×1600 or 584×327×132
Medium System
Medium System
Small System
Small System
Medium System
PS4875/25
P S482 50-1C/29 00
PS24600/75
PS48 165 /320 0
PS48360/1800
PS48300/1800-X6
PS48120/1800-X6
Max. Power
20.88kW
17.4kW
6.96kW
4.35kW
17.4kW
7.2kW
PSC48150/25
Voltage
-48V
-48V
-48V
-48V
+24V
-48V
Max. Current
360A
300A
120A
75A
600A
150A
Max. Number of Rectifiers
12
10
4
3
8
6
Rectifier Type
R48-1800
R48-1800
R48-1800
HD4825-3
HD2475-2
C24/48-1200
Controller Type
M501D
M501D
M501D
PSM-A10
PSM-A11
Dimension
600×600×2000
600×600×1600
600×600×2000
450×260×700
600×600×2000
200×400×1460
Business-Critical Continuity™
NetSure 801 Stand-alone DC Power Series -48VDC up to 348kW
R48-5800
Applications
Large and medium switching offi ce Level-1 transmission backbone line GSM mobile switching office, mobile tandem e xchange CDMA mobile switching office, mobile tandem e xchange DC Internet data center
M810G
System features
Space saving, 116kW(2000A@58V) capacity one cabinet Capacity expandable up to 348kW(6000A@58V) Three-phase rectifi ers (R48-5800) and SCU+(M810G) inside Wide AC input range, 260V to 530Vac, up to 600Vac endurance without damage System Effi ciency high up to 93% Power factor high up to 0.99 Output current Walk-in available Rectifiers and controller hot swappable Front access Top or bottom cabling Surge protection on AC, DC and signal side Modularized design for system and function unit TCP/IP, SNMP, web browser support Rectifier CE/UL approved Compliance with EN60590 and EN300386, ROHS Patented energy-saving mode
3
DC Power System
Affi liated Cabinet AC distribution cabinet
Features
Local large LCD display Dual mains auto/manual switchover Front access, Top / bottom cabling DC emergency lighting available Expandable up to f ive AC cabinets Lightning proof and electric Compliance with IEC ROHS Compatible
AC distribution cabinet
DC distribution cabinet Features
DC distribution cabinet
4
Independent monitoring unit for decentralized supply Local large LCD display Front access, Top / bottom cabling DC emergency lighting available Expandable up to 8 DC cabinets Lightning proof and electric Compliance with IEC ROHS Compatible
Business-Critical Busines s-Critical Continuity™
PD48/2000HF High Ohmic Power Distribution Cabinet
Features
Up to 120 branches high/low ohmic output Local large LCD display Front access Lightning proof and electric Compliance with IEC ROHS Compatible
PD48/2000HF
PD48/1200BFH Integrated AC/DC Distribution Cabinet Features
AC.DC distribution unit in one cabinet Space saving Local large LCD display Dual mains auto/manual switchover Front access Lightning proof and electric Compliance with IEC ROHS Compatible
Dimensions And Weight Cabinet Rectifier Rack
AC Cabinet
DC Cabinet DC High Ohmic Distribution Cabinet Integrated AC/DC Distribution Cabinet Rectifier Controller
Cabinet / module Rack10 Rack 1000 00-6 -6 Ca Cabi bine nett Rack Ra ck20 2000 00-6 -6 Ca Cabi bine nett PD38 PD 380/ 0/40 400A 0AFH FH-6 -6/X /X1 1 PD380/ PD3 80/630A 630AFHFH-6/X 6/X1 1 PD380/630AFA PD48 PD 48/1 /160 600D 0DFF-6/ 6/X1 X1 PD48 PD 48/2 /250 500D 0DFF-6/ 6/X1 X1
capacity 1000 10 00A A 2000 20 00A A 400A 40 0A 630A 630A 1600 16 00A A 2500 25 00A A
W×D×H, mm 600×600×2000 600 600 60 0×600×2000 800 80 0×600×2000 800×600×2000 800×600×2000 800 80 0×600×2000 800 80 0×600×2000
Weigh t ( kg kg) 140(exclude recti 140(exclude rectifier) fier) 180(exclude 180(exc lude recti rectifier) fier) 240 240 Manual switchover 250 Automatic switchover 280 290
PD48/2000HF
2000A
800×600×2000
320
P D4 D48 /1 /120 0B 0BF H
1 20 200 A
800×600×2000
320
R48-5800 M810G
5800W /
244×372×88 243.5×161×88
7.8 2
PD48/1200BFH
DC Power System
PS48600-3/2900-X5 Integrative DC Power Series -48VDC up to 34.8kW
Applications
PS48600-3/2900-X5
2G, 3G mobile base stations Medium exchanges, rural telecom networks and access networks Transmission relay stations Microwave/satellite communications stations
Features
R48-2900
M500F
Capacity up to 34.8kW (600A @ 58V) Rectifiers R48-2900(2900W)and SCU inside Wide input voltage range (85 to 290Vac), up to 415Vac endurance without damage Effi ciency high h igh up to 93% 93 % Power factor high up to 0.99 Output current Walk-in available Patented energy-saving mode available Intelligent monitoring and remote control Surge protection on AC, DC and signal side Rectifiers and controller hot swappable Front access Top or bottom cabling Rectifi Recti fier CE/UL approval appro val Compliance with RoHS
Dimensions And Weight Cabinet Rectifier Controller
6
model PS48600-3/2900-X5 R48-2900 M500F
W×D×H, mm 600×600×20 2000 00 85.5×287×132.5
Weight (kg) 140( 14 0(re rect ctifi ifier ex excl clud uded ed)) 3.5
Business-Critical Continuity™
PS48250-1A/2900 PS48250-1B/2900 PS48250-1C/2900 (ACTURA Flex 48330) Integrative DC Power Series -48VDC up to 14.5kW Applications
2G, 3G mobile base stations Medium exchanges, rural telecom networks and access networks Transmission relay stations Microwave/satellite communications stations
PS48250-1A/2900
Features
Capacity up to 14.5kW (250A @ 58V) Rectifiers R48-2900(2900W)and SCU inside Super fl exible confi guration Wide input voltage range (85 to 290Vac), up to 415Vac endurance without damage Effi ciency high up to 93% Power factor high up to 0.99 Output current Walk-in available Patented energy-saving mode available Intelligent monitoring and remote control Surge protection on AC, DC and signal side Rectifiers and controller hot swappable Front access Top cabling Inner 660Ah battery shelves optional Rectifier CE/UL approval Compliance with RoHS
Dimensions And Weight Cabinet Rectifier Controller
model PS48250-1A/2900 PS48250-1B/2900 PS48250-1C/2900 R48-2900 M500F
PS48250-1B/2900
PS48250-1C/2900 W×D×H, mm 600×600×2 00 0 600×400×2 00 0 600×400×7 00 85.5×287×132.5
Weight (kg) 1 35 (r ec ti fier ex cl ud ed) 1 25 (r ec ti fier ex cl ud ed) 6 0 ( rec ti fier ex cl ud ed) 3.5
7
DC Power System
PS48165/3200 (ACTURA OPTIMA 48200) Integrative DC Power Series -48VDC up to 9.6kW Applications
2G, 3G mobile base stations Medium exchanges, rural telecom networks and access networks Transmission relay stations Microwave/satellite communications stations
PS48165/3200 mode1
Features
PS48165/3200 mode2
PS48165/3200 mode3
Capacity up to 9.6kW (165A @ 58V) Rectifiers R48-3200(3200W)and SCU inside Wide input voltage range (85 to 290Vac), up to 415Vac endurance without damage Effi ciency high up to 93% Power factor high up to 0.99 Output current Walk-in available Patented energy-saving mode available Intelligent monitoring and remote control Surge protection on AC, DC and signal side Rectifiers and controller hot swappable Top cabling Inner dual battery shelves optional Rectifier CE/UL approval Compliance with RoHS
Dimensions And Weight Cabinet S ub rac k
8
model PS48165/3200 mode 1 PS48165/3200 mode 2 P S4 81 65 /3 20 0 m od e 3
W×D×H, mm 600×600×1600 600×400×1600 5 84×327×132
Weight (kg) 75(rectifier excluded) 65(rectifier excluded) 20(rectifier excluded)
Distribution U nit Location Top rear
Business-Critical Continuity™
PS48360/1800 (ACTURA Flex 48420) Integrative DC Power Series -48VDC up to 20.8kW Applications
2G, 3G mobile base stations Medium exchanges, rural telecom networks and access networks Transmission relay stations Microwave/satellite communications stations
R48-1800
Features
Capacity up to 20.8kW (360A @ 58V) Rectifiers R48-1800(1740W)and SCU inside Wide input voltage range (85 to 300Vac), up to 415Vac endurance without damage Efficiency high up to 92% Power factor high up to 0.99 Output current Walk-in available Patented energy-saving mode available Intelligent monitoring and remote control Surge protection on AC, DC and signal side Rectifiers and controller hot swappable Front access Top cabling Inner 660Ah battery shelves optional Rectifier CE/UL approval Compliance with RoHS
Dimensions And Weight Cabinet
model PS48360/1800-X1 PS48360/1800-X2 PS48360/1800-X3
W×D×H, mm 600×600×2 00 0 600×400×2 00 0 600×600×1 80 0
Weight (kg) 1 35 (r ec tifi er e xc lu ded ) 1 25 (r ec tifi er e xc lu ded ) 1 00 (r ec tifi er e xc lu ded )
M501D
PS48360/1800
DC Power System
PS48300/1800-X6 Integrative DC Power Series -48VDC up to 14.7kW Applications
PS48300/1800-X6
Features
M501D
2G, 3G mobile base stations Medium exchanges, rural telecom networks and access networks Transmission relay stations Microwave/satellite communications stations
Capacity up to 14.7kW (300A @ 58V) Rectifiers R48-1800(1740W)and SCU inside Wide input voltage range (85 to 300Vac), up to 415Vac endurance without damage Effi ciency high up to 92% Power factor high up to 0.99 Output current Walk-in available Patented energy-saving mode available Intelligent monitoring and remote control Surge protection on AC, DC and signal side Rectifiers and controller hot swappable Front access Top/Bottom cabling Rectifier CE/UL approval Compliance with RoHS
Dimensions And Weight Cabinet
R48-1800
10
model PS48300/1800-X6
W×D×H, mm 600×600×1600
Weight (kg) 130(rectifier excluded)
Business-Critical Continuity™
PS48120/1800-X6 Integrative DC Power Series -48VDC up to 6.96kW Applications
2G, 3G mobile base stations small exchanges, rural telecom networks and access networks Transmission relay stations Microwave/satellite communications stations Railway stations
Features
PS48120/1800-X6
Capacity up to 6.96kW (120A @ 58V) Rectifiers R48-1800(1740W)and SCU inside Wide input voltage range (85 to 300Vac), up to 415Vac endurance without damage Effi ciency high up to 92% Power factor high up to 0.99 Output current Walk-in available Patented energy-saving mode available Intelligent monitoring and remote control Surge protection on AC, DC and signal side Rectifiers and controller hot swappable Front access Top/Bottom cabling Inner 330Ah battery shelves optional Rectifier CE/UL approval Compliance with RoHS
M501D
Dimensions And Weight Cabinet
model PS48120/1800-X6
W×D×H, mm 600×600×2 00 0
Weight (kg) 1 10 (r ec tifier e xc lu ded )
R48-1800
11
DC Power System
PS4875/25 Wall-mounted Integrative DC Power Series -48VDC up to 4.35kW Applications
PS4875/25
2G, 3G mobile base stations Small exchanges, rural telecom networks and access networks Transmission relay stations Microwave/satellite communications stations Railway stations
Features
Capacity up to 4.35kW (75A @ 58V) Rectifiers HD4825-3(1450W )inside Wall-mounted for space saving Wide input voltage range (90 to 290Vac), up to 415Vac endurance without damage Effi ciency high up to 90% Power factor high up to 0.99 Output current Walk-in available Patented energy-saving mode available Intelligent monitoring and remote control Surge protection on AC, DC and signal side Rectifiers and controller hot swappable Front access Top cabling Rectifier CE approval Compliance with RoHS
Dimensions And Weight Cabinet
12
model PS4875/25
W×D×H, mm 450×260×7 00
Weight (kg) 4 0( re cti fier e xc lu ded )
Business-Critical Continuity™
PS4890/800 (ACTURA 48201) Subrack DC Power Series -48VDC up to 4.8kW Applications
2G, 3G mobile base stations small access networks Microwave/satellite communications stations
Features
19” Subrack system Capacity up to 2.4kW one subrack, 4.8kW dual subracks Rectifiers R48-800(800W)and SCU inside Wide input voltage range (85 to 300Vac) Effi ciency high up to 91% Power factor high up to 0.99 Output current Walk-in available Patented energy-saving mode available Intelligent monitoring and remote control BLVD, LLVD optional Rectifiers and controller hot swappable Rectifier CE/UL approval Compliance with RoHS
Dimensions And Weight model PS4890/800 single subrack PS4890/800 dual subracks
W×D×H, mm 485×345×90 485×345×180
Weight (kg) 8.8(rectifier excluded) 17.9(rectifier excluded)
13
DC Power System
PS24600/75 Integrative DC Power Series +24VDC up to 17.4kW Applications
PS24600/75
2G, 3G mobile base stations Medium exchanges, rural telecom networks and access networks Transmission relay stations Microwave/satellite communications stations
Key Features
Capacity up to 17.4kW (600A @29V) Rectifiers HD2475-2(2175W )inside Wide input voltage range (120 to 290Vac), up to 415Vac endurance without damage Effi ciency high up to 88% Power factor high up to 0.99 Intelligent monitoring and remote control Surge protection on AC, DC and signal side Rectifiers and controller hot swappable Front access Top or bottom cabling Rectifier CE approval Compliance with RoHS
Dimensions And Weight Cabinet Rectifier Controller
14
model PS48600-3/2900-X5 HD2475-2 PSM-A11
W×D×H, mm 600×600×2 00 0 105 ×400×245
Weight (kg) 1 58 (r ec ti fier ex clu de d) 8
Business-Critical Continuity™
PSC48150/25 Integrative DC Power Series +24Vdc/-48Vdc, 7.2kW Applications
2G, 3G mobile base stations Medium exchanges Transmission relay stations Microwave/satellite communications stations
Features
+24V/-48V DC/DC system Capacity up to 7.2kW Wide DC input voltage range: 21V~29V DC/DC module(1200W)inside DC/DC converter Hot-swappable Extremely low radiation, meeting Relay output for alarm port Complete lightning proof in input and output rated at 5KA(8/20us) Complete fault protection functions Optional remote monitor and control Front access Compliance with RoHS
PSC48150/25
Dimensions And Weight Cabinet DC/DC converter
model PSC48150/25 C24/48-1200
W×D×H, mm 200×400×146 0 85.5×287×132.5
Weight (kg) 45 (rectifier excluded) 2.5
1
EMERSON NETWORK POWER. THE GLOBAL LEADER IN ENABLING BUSINESS-CRITICAL CONTINUITY.™
AC POWER CONNECTIVITY DC POWER EMBEDDED COMPUTING EMBEDDED POWER
OUTSIDE PLANT MONITORING OUTSIDE PLANT POWER SWITCHING & CONTROLS PRECISION COOLING RACKS & INTEGRATED CABINETS SERVICES SURGE PROTECTION
Protecting and moving voice ,video and data from the central office closer to the subscriber. We deliver a f ull line of enclosures,cabinets and shelters that meet the networked world’s demands for high speed without interruption, from MESA® and DEC integrated enclosure solutions to Emerson Network Power ES, EC, EPC outdoor power solutions to cross-connects to ProFORM® distribution terminals to NetSpanTM Integrated FTTx Solutions.
OUTSIDE PLANT. Yet another way Emerson Network power enables Business-Critical Continuity™.
16
Business-Critical Continuity™
EPC48180/1800-FA -48VDC Outdoor Power Cabinet Applications
Outdoor stations of GSM, UMTS, CDMA Fiber optic transmission systems Digital loop carriers
Features
Capacity up to 10.44kW (180A @ 58V) Totally front access in favor of space-saving Forced vent cooling system Patent design of Isolated air channel for safe operation IP55 for equipment chamber Forced vent cooling for battery chambers Wide input voltage range (85 to 300Vac), up to 415Vac endurance without damage Rectifiers R48-1800(1740W) and SCU inside Efficiency high up to 92% Power factor high up to 0.99 Output current Walk-in available Perfect fan speed control for energy-saving Patent energy-saving mode available Intelligent monitoring and remote control Surge protection on AC, DC and signal side Class B+C lightning protection optional Rectifiers and controller hot swappable Inner dual 330Ah battery Chambers Rectifier CE/UL approval Compliance with EN60950 and IEC60950, RoHS H-mast platform installation available
EPC48180/1800-FA
Dimensions And Weight Cabinet
model EPC48180/1800-FA
W×D×H, mm 700×700×1700
Weight (kg) 150(rectifiers and batteries excluded)
17
Outside Plant
EPC48120/1800-F -48VDC Outdoor Power Cabinet Applications
EPC48120/1800-F
Outdoor stations of GSM, UMTS, CDMA Fiber optic transmission systems Digital loop carriers
Features
Capacity up to 6.96kW (120A @ 58V) Totally front access in favor of space-saving Forced vent cooling system IP45 for equipment chamber Patent design of Isolated air channel for safe operation Forced vent cooling for battery chambers Wide input voltage range (85 to 300Vac), up to 415Vac endurance without damage Rectifiers R48-1800(1740W)and SCU inside Effi ciency high up to 92% Power factor high up to 0.99 Output current Walk-in available Perfect fan speed control for energy-saving Patent energy-saving mode available Intelligent monitoring and remote control Surge protection on AC, DC and signal side Class B+C lightning protection optional Rectifiers and controller hot swappable Inner dual 330Ah battery Chambers Rectifier CE/UL approval Compliance with EN60950 and IEC60950, RoHS H-mast platform installation available
Dimensions And Weight Cabinet
18
model EPC48120/1800-F
W×D×H, mm 600×630×1500
Weight (kg) 140(rectifiers and batteries excluded)
Business-Critical Continuity™
EPC48120/1800-HA(B) -48VDC Outdoor Power Cabinet Applications
Outdoor stations of GSM, UMTS, CDMA Fiber optic transmission systems Digital loop carriers
Features
Capacity up to 6.96kW (120A @ 58V) Totally front access in favor of space-saving Heat-exchange cooling system IP55 for equipment chamber Wide operation temperature, -40~+45℃ optional Patent design of Isolated air channel for safe operation Forced vent cooling for battery chambers Wide input voltage range (85 to 300Vac), up to 415Vac endurance without damage Rectifiers R48-1800(1740W)and SCU inside Efficiency high up to 92% Power factor high up to 0.99 Output current Walk-in available Perfect fan speed control for energy-saving Patent energy-saving mode available Intelligent monitoring and remote control Surge protection on AC, DC and signal side Class B+C lightning protection optional Rectifiers and controller hot swappable Inner dual 330Ah battery Chambers Rectifier CE/UL approval CE mark Compliance with EN60950 and IEC60950, RoHS H-mast platform installation available
EPC48120/1800-HB
Dimensions And Weight Cabinet
model EPC48120/1800-HA EPC48120/1800-HB
EPC48120/1800-HA
Op. temp. -10 +45℃ -40 +45℃ ~
W ×D×H, mm
Weight (kg)
600×600×1700
150(rectifiers and batteries excluded)
~
19
Outside Plant
EC200T/01 Outdoor Battery Cabinet Applications
EC200T/01
Outdoor stations of GSM, UMTS, CDMA Fiber optic transmission systems Digital loop carriers
Features
Cater up to 3 strings of 165Ah batteries Thermoelectricity cooler (TEC) inside Inner temperature 5~15℃ below outside ambient IP55 Dry-contact alarm for fans and door sensor Compliance with RoHS
Dimensions And Weight Cabinet
20
model EC150F/01
Op. temp. -10 +55℃ ~
W×D×H, mm 650×720×1 40 0
Weight (kg) 1 00 (ba tt eri es e xc lu ded )
Business-Critical Continuity™
EC150F/01 Outdoor Battery Cabinet Applications
Outdoor stations of GSM, UMTS, CDMA Fiber optic transmission systems Digital loop carriers
EC150F/01
Features
Cater up to 2 strings of 165Ah batteries Forced vent cooling IP34 Dry-contact alarm for fans and door sensor Compliance with RoHS
Dimensions And Weight Cabinet
model EC150F/01
Op. temp. -10~+45℃
W ×D×H, mm 700×700×1 00 0
Weight (kg) 1 00 (b at ter ies ex cl ude d)
21
Outside Plant
EC100F/01 Outdoor Battery Cabinet Applications
Outdoor stations of GSM, UMTS, CDMA Fiber optic transmission systems Digital loop carriers
EC100F/01
Features
Cater up to 2 strings of 165Ah batteries Forced vent cooling IP34 Dry-contact alarm for fans and door sensor Compliance with RoHS
Dimensions And Weight Cabinet
22
model EC100F/01
Op. temp. -10 +45℃ ~
W×D×H, mm 600×600×1 00 0
Weight (kg) 1 00 (ba tt eri es e xc lu ded )
EMERSON NETWORK POWER. THE GLOBAL LEADER IN ENABLING BUSINESS-CRITICAL CONTINUITY.™
AC POWER CONNECTIVITY DC POWER EMBEDDED COMPUTING EMBEDDED POWER
AC POWER MONITORING OUTSIDE PLANT POWER SWITCHING & CONTROLS PRECISION COOLING RACKS & INTEGRATED CABINETS SERVICES SURGE PROTECTION
Sustaining critical operations that simply can ’t go down. We deliver a full range of uninterruptible Liebert® AC power systems and complete associated power distribution and enclosures , from individual products to integrated systems that keep network closets up and running.
AC Power. Yet another way Emerson Network Power enables Business-Critical Continuity™.
23
AC Power
AC POWER Confi guration Matrix
24
Small System
Medium System
Small System
SERIES:
US11R
iTrust 31
iTrust 2G
RATING:
1/2/3KVA
10/15/20KVA
3/6/9/12/15/18KVA
MOUNTING:
Tower/Rack
Tower
Tower/Rack
I/O:
1-ph./1-ph.
3-ph./1-ph.
1-ph./1-ph.
VOLTAGE:
220/230/240 (L-N)
380/220
220 (L-N)
FREQUENCY:
50Hz
50Hz
50Hz
Large system
Medium System
SERIES:
NX
Hipulse-U
RATING:
10/15/20/30/40/60/80/100/120/140/160/200KVA
MOUNTING:
Tower
Tower
Tower
I/O:
3-ph./3-Ph.
3-ph./3-ph.
1-ph./1-ph.
VOLTAGE:
380/400/415 (L-L)
380/400/415 (L-L)
220(L-N)
FREQUENCY:
50/60Hz
50/60Hz
50Hz
160/200/300/400KVA
Outdoor UPS 2KVA/3KVA
Business-Critical Continuity™
US11-R Series 1/2/3KVA
Applications
Servers/Storage/Workstation Telecommunication, VoIP Small Office Network Data Warehouses Medical Diagnostics Process Automation Equipmentsv
Special Features
Rack/Tower design, adaptable for table and 19' IT rack application Double conversion, true on-line style Fully digital control Input surge suppressor equipped CE marked IGBT based rectifier and excellent input performance Super wide input window Mutiple AC output connections 2U height High EMC performance, classB achieved Intelligent battery management
Dimensions And Weight Model Name US11R-0010 US11R-0010L US11R-0020 US11R-0020L US11R-0030 US11R-0030L UF-B0007-06 UF-B0009-06
Size(WDH in MM) 440×400×87 440×400×87 440×400×87 440×400×87 440×400×87 440×400×87 440×400×87 440×400×87
Weight(Kg) 17.5 7.8 29.1 9.6 30.5 10.5 20.5 21.5
Note: US11R-0020 will be shipped with a VF-B0007-06 US11R-0023 will be shipped with a VF-B0009-06
25
AC Power
US11-R Series Datasheet US11R-0010 US11R-0010L 1KVA
Model Nominal Power Rating at 0.7 PF Input Parameters Rectifier Type
IGBT-based PFC(Power Factor Correction)
Input Voltage
220Vac,
Permissible Input Voltage Range Permissible Input Frequency Range Input Power Factor at nominal voltage Battery Battery Type Nominal Battery Bus Recharging Time to 90% Recovery Output Parameters Inverter Type Output Power Output Connection Output Voltage Output Frequency Output Voltage THD Capability to handle High Crest Factor Load Capability to handle Step L oad
120-288Vac 50Hz ±2%,5%,7%,10% User selectable ≥0.99
Overload Capability
System Parameters & Standards AC-AC Efficiency Switch Time When Input Fails Noise Display Dimension (W×D×H)mm U-Height Weight (Standard/L model) Safety EMI /EMC Inmunity Surge Protection Protection Communication & Management Interface Port Web/SNMP Card Environmental Parameters Operating Temperature Range Relative Humidity Maximum Altitude above MSL
26
US11R-0020 US11R-0020L 2KVA
US11R-0030 US11R-0030L 3KVA
1-ph, 3-w
Maintenace Free, V RLA (Valve Regu lated Lead Acid) 36Vdc 72Vdc 90%
0s 91%
>92%
0s
View more...
Comments