Insulated Case Circuit Breakers
Section 5: Insulated Case Circuit Breakers
S E R S E A K C A E D R E B T T A I L U U C S R I N I C
5
Power Break Insulated Case Circuit Breakers In 1965 GE pioneered the design of insulated case circuit breakers when it introduced the original Power Break circuit breaker. Power Break I offered rugged system protection for heavy-duty applications in a reliable, cost-effective insulated case. Power Break I can still be equipped with either a dual magnetic trip for dc applications or the latest in electronic trip protection for ac system protection and moni- toring. When GE introduced Power Break II, the original benchmark for performance and reliability was dramatically improved for ac systems, while maintaining the original insulated case circuit break- er features in a contemporary, compact physical envelope. Today, GE continues to offer both lines of breakers to cover the range of ac and dc power system protection and control needs as well as the continuing needs of the systems originally designed around these capable circuit breakers.
Insulated Case Circuit Breakers
Publication References ..................... .......................................... .......................................... ............................5-2 .......5-2 Power Break‚ I and II Selection Guide............................................5-4 Power Break II
Features ................... ........................................ .......................................... .......................................... ...................................5-5 ..............5-5 Trip Unit Features .................... .......................................... ........................................... ......................................5-7 .................5-7 Trip Unit Characteristics ................... ........................................ .......................................... ............................5-8 .......5-8 Product Number Nomenclature System.......................................5-10 Interrupting Capacity and Withstand Ratings..............................5-13 How to Order....................................... Order............................................................ .......................................... ..........................5-14 .....5-14 Basic Frame Selection .................. ....................................... ........................................... ..............................5-15 ........5-15 Stationary and Draw-out Switch Selection..................................5-16 Trip Unit Selection – How to Order ................... ........................................ .............................5-17 ........5-17 Enhanced MicroVersaTrip MicroVersaTrip Rating Plug Selection ...................... .......................5-19 .5-19
Neutral Current Sensors and POWER LEADER Accessories..................... Accessories.......................................... ..................................5-21 .............5-21 Stationary and Draw-out Breaker Accessories ..................... ..........................5-22 .....5-22 Stationary Breaker Mounting Kits........................... Kits................................................ .......................5-27 ..5-27 Draw-out Breakers and a nd Accessories ..................... .......................................... .......................5-29 ..5-29 Power Break I Circuit Breakers
Ratings and Trip Characteristics ...................... ........................................... ..............................5-31 .........5-31 Draw-out Breakers .................... ......................................... .......................................... ..................................5-32 .............5-32 How to Order...................................... Order........................................................... .......................................... ...........................5-33 ......5-33 Ratings and Trip Characteristics ...................... ........................................... ..............................5-34 .........5-34 Trip Unit Features ................... ......................................... ........................................... .....................................5-36 ................5-36 Power Break I Circuit Breakers with Enhanced MicroVersaTrip MicroVersaT rip Plus and MicroVersaTrip PM Trip Units—Technical Units—Technical Data, Trip Unit Characteristics..............5-37 Power Break I Circuit Breakers with MagneTrip Unit—How to Order ..................... .......................................... ..............................5-38 .........5-38 Power Break I Circuit Breakers with Enhanced MicroVersaTrip MicroVersaT rip Plus and MicroVersaTrip PM Trip Units—Frame Selection ................... ......................................... ......................................5-40 ................5-40 Stationary Switches, Draw-out Switches ..................... .....................................5-41 ................5-41 Frame Modification Features ..................... .......................................... .....................................5-42 ................5-42 Power Break I Circuit Breakers with Enhanced MicroVersaTrip Plus and MicroVersaTrip MicroVersaT rip PM Trip Units—How to Order ..................... ..........................5-43 .....5-43 Rating Plug Selection ................... ......................................... ........................................... ..............................5-45 .........5-45 Accessories.................................... Accessories............... ........................................... ........................................... ..............................5-46 .........5-46 Enclosures ..................... .......................................... .......................................... .......................................... ...........................5-54 ......5-54
Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com Rev. 12/04
www.geelectrical.com
BuyLog Catalog
5-1
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Insulated Case Circuit Breakers S E R S E A K C A E D R E B T T A I L U U C S R I N I C
5
Associated Devices and Accessories
UL/CSA File Numbers Power Break Breakers ..................... ........................................... ...........................E11592/LR102 .....E11592/LR10263 63 MicroVersaTrip MicroVersaT rip Plus and MicroVersaTrip PM and Power+ Trip Units .................... .......................................... ...........................E11592/LR102 .....E11592/LR10263 63 MicroVersaT MicroVersaTrip and Power+ Rating...........................E57253/LR102 Plugs ...............E115 ...............E11592/LR10263 92/LR10263 Accessories rip ........................................ ................... ........................................... .....E57253/LR10263 63 Molded Case Switches.................................... Switches................................................E57546 ............E57546/LR16271 /LR16271
Power Break II Time Current Curve-Numbers Functions
Enhanced MicroVersaTrip Plus™ and MicroVersaTrip PM™ Trip Units
Curve No.
Long-time Delay with Instantaneous or Long-time Delay, Short-time Delay with Instantaneous
GES-9889
Ground Fault
GES-9890
Power Break II Circuit Breaker Accessories– Draw-Out Substructure Rail Kit ................... ........................................ .......................GEH-6440 ..GEH-6440 Walking Beam Interlock 800A, 1600A, 2000A .................... .....................GEH-6286 .GEH-6286 Walking Beam Interlock 2500-3000A...... 2500-3000A........................... ................................DEH-009 ...........DEH-009 Walking Beam Interlock 4000A .................. ........................................ .............................DEH-010 .......DEH-010 Draw Out Mechanical Interlock Inte rlock 800-2000A..........................DEH-011 Draw Out Mechanical Interlock Inte rlock 2500-4000A........................DEH-012 Neutral Kit ................... ........................................ .......................................... ........................................... ......................DEH-024 DEH-024 Hidden “ON” Button........................... Button................................................ .......................................DEH ..................DEH-025 -025 High Voltage Shunt Trip............................ Trip................................................. ..............................GEH-6519 .........GEH-6519 High Voltage Under Voltage Release ................... ...................................GEH-65 ................GEH-6520 20 Under Voltage Release Time Delay Relay ...........................GEJ-4699 ...........................GEJ-4699
Power Break II Circuit Breakers Trip Units Power+ Tri Trip p Unit ................... ........................................ .......................................... ................................DEH-049 ...........DEH-049
Power Break II Instructions for Breakers and Accessories Power Break II Circuit Breakers– 800-4000 A frames, 240-600 Vac..........................................GEH-62 Vac..........................................GEH-6270 70 Power Break II Circuit Breakers– Draw-Out 800-4000 Ampere Frames ................... ..................................GEH-62 ...............GEH-6271 71 Power Break II Circuit Breakers– Draw-Out Substructure .................... ......................................... ....................................GEH-62 ...............GEH-6272 72 Power Break II Circuit Breakers–Trip Unit ..................... .........................GEH-6273 ....GEH-6273 Power Break II Circuit Breaker Accessories– Auxiliary Switch Module Module..................... ........................................... .................................GEH-6274 ...........GEH-6274 Power Break II Circuit Breaker Accessories– Bell Alarm-Alarm Only.................................... Only......................................................... ......................GEH-6275 .GEH-6275 Power Break II Circuit Breaker Accessories– Door Interlock ...................... ........................................... .......................................... .............................GEH-6276 ........GEH-6276 Power Break II Circuit Breaker Accessories– Lug Kits and T Studs ..................... .......................................... ........................................GEH ...................GEH-4546 -4546 Power Break II Circuit Breaker Accessories– Bell Alarm with Lockout ................... ........................................ ....................................GEH-62 ...............GEH-6278 78 Power Break II Circuit Breaker Accessories– Key Interlock Provision .................... ......................................... ....................................GEH-62 ...............GEH-6279 79 Power Break II Circuit Breaker Accessories– Mechanical Counter ..................... .......................................... ........................................GEH ...................GEH-6280 -6280 Power Break II Circuit Breaker Accessories– Motor Operator Mechanism.......................... Mechanism............................................... ......................GEH-6281 .GEH-6281 Power Break II Circuit Breaker Accessories– Push Button Cover ..................... .......................................... .......................................... ......................GEH-6282 .GEH-6282 Power Break II Circuit Breaker Accessories– Remote Close ................... ........................................ .......................................... .................................GEH-6283 ............GEH-6283 Power Break II Circuit Breaker Accessories– Shunt Trip................... Trip........................................ .......................................... ........................................GEH ...................GEH-6284 -6284 Power Break II Circuit Breaker Accessories– Undervoltage Release ..................... ........................................... .....................................GEH-62 ...............GEH-6285 85 Power Break II Circuit Breaker Accessories– Walking-Beam Interlock ..................... .......................................... .................................GEH-6286 ............GEH-6286 TVRMS2 Test Kit.............................. Kit................................................... .......................................GEK-9 ..................GEK-97367 7367 Power Break II Circuit Breaker Accessories–
Power Break II Circuit Breakers Rating Plugs........................... Plugs................................................ .......................................... ..............................GEH-5933 .........GEH-5933 Enclosures 800-2000A............................ 800-2000A................................................. .................................GEH-650 ............GEH-65033
Power Break II Insulated Case Switches 800-4000A, 240-600 Vac........... Vac................................ ........................................... .........................DEH-40380 ...DEH-40380 Power+ Control Units................................ Units..................................................... ............................DEH-40381 .......DEH-40381
Power Break I Time Current Curve Numbers Functions
MicroVersaTrip Plus™ and MicroVersaTrip PM™ Trip Units
Frame
Curve No.
Long-time Delay with Instantaneous or Long-time Delay, Short-time Delay with Instantaneous
80 0A 0A -4 -40 00 00 A
G ES ES- 99 99 09 09
Ground Fault
800A-4000A
GES-9911
1 20 20 0A0A-1 1 60 60 0A 0A 2000A
G ES ES -6 -6 16 16 4 GES-6165
Long-time Delay with Instantaneous MagneTrip™ Trip Unit Long-time Delay, Short-time Delay
2500A
GES-6166
3 00 00 0A0A-4 4 00 00 0A 0A
G ES ES -6 -6 16 16 7
1 20 20 0A0A-1 1 60 60 0A 0A
G ES ES -6 -6 16 16 8
2000A
GES-6169
2500A
GES-6170
3 00 00 0A0A-4 4 00 00 0A 0A
G ES ES -6 -6 17 17 1
Draw-Out Substructure Secondary Disconnect..............GEH-6460
distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
5-2
BuyLog Catalog
www.geelectrical.com
Rev. 12/04
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Insulated Case Circuit Breakers Associated Devices and Accessories
S E R S E A K C A E D R E B T T A I L U U C S R I N I C
GE Power Break I Technical Publications For more information on these products, order publications listed in Sections 21 and 22.
General Instructions, Breakers and Accessories Circuit Breaker Construction Details (800-4000A) ..............GEF-4 ..............GEF-4458 458 MicroVersaTrip MicroVersaT rip Plus and MicroVersaTrip PM Trip Unit....GEH-6273 MicroVersaTrip MicroVersaT rip Plus and MicroVersaTrip PM Rating Plugs for Power Break and AKR Circuit Breakers ..........GEH-5933 MagneTrip Trip Unit (2500-3000A)........................... (2500-3000A).........................................GEH-465 ..............GEH-46588 Power Break Circuit Breaker (800-2000A) General Information, Accessory Installation ...................GEH-4693 ...................GEH-4693 Power Break Circuit Breaker (2500-4000A) General Information, Accessory Installation ...................GEH-4694 ...................GEH-4694 Power Break Draw-out Breakers (800-4000A) ...................G ...................GEH-4698 EH-4698
5
Field Installed Accessories and Options Padlock Accessory (2500-4000A)........... (2500-4000A)................................ ...............................GEH-3394 ..........GEH-3394 Bell Alarm For MagneTrip (2500-4000A) (2500-4000A) .................... ..............................GEH-3403 ..........GEH-3403 Terminal Board For Accessories (800-4000A) ....................GEH-3407 ....................GEH-3407 Circuit Breaker Enclosure (800-4000A) .................. ................................GEH-349 ..............GEH-34988 Lug Kits (2500-4000A)...................................... (2500-4000A)........................................................... ........................GEH-4303 ...GEH-4303 Key Interlock Mounting Mount ing (800-2000A) ................... ....................................GEH-4 .................GEH-4324 324 Key Interlock Mounting Mount ing (2500-4000A) .................... ..................................GEH-434 ..............GEH-43411 Bell Alarm For MicroVersaT MicroVersaTrip rip RMS-9 (2500-4000A) ................... ........................................ .......................................... ...................................GEH-435 ..............GEH-43588 Mechanical Interlock-Stationary Breakers (800-4000A) ..................... .......................................... .......................................... ...................................GEH-438 ..............GEH-43833 Remote Close Option (2500-4000A)............... (2500-4000A).................................... ........................GEH-4544 ...GEH-4544 Lug Kits (800-2000A) (800-2000A).................. ........................................ ........................................... ........................GEH-4546 ...GEH-4546 Power Break Draw-out Secondary Disconnect (800-4000A) ..................... .......................................... .......................................... ...................................GEH-469 ..............GEH-46966 Power Break Draw-out Substructure, Accessories (800-4000A)................... (800-4000A)........................................ ...................................GEH-469 ..............GEH-46977 Power Break Draw-out Position Switch ................... ...........................DEH-40528 ........DEH-40528 Power Break “Off” Button Activated Motor Cutoff Cu toff Switch (2500-4000A)................. (2500-4000A)......................................G .....................GEH-4699 EH-4699 Power Break Draw-out Mechanical Interlock (800-4000A) ..................... .......................................... .......................................... ...................................GEH-500 ..............GEH-50066 Digital Test Kit MicroVersaTrip-Trip Units (Product Number TVRMS2) .................... ......................................... ...........................GEK-97367 ......GEK-97367 Portable Battery Pack (Product Number TVPBP)................DEJ-001 Replacement Parts Replacement Trip Units ................... ......................................... .......................................GEH-6 .................GEH-6303 303
Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com Rev. 12/04
www.geelectrical.com
BuyLog Catalog
5-3
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break I and II Selection Guide S E R S E A K C A E D R E B T T A I L U U C S R I N I C
5
The interruption ratings and voltages shown in the table are maxi- mum ratings. A circuit breaker of the type given in the left-hand column may be applied at the given circuit voltage in any electrical distribution system where the available fault current at the load terminals of the breaker does not exceed the value in the table. That circuit breaker breaker type may also be applied at intermediate values of circuit voltage provided the available available fault current at the load terminals of the breaker breaker does not exceed the value in the table for the higher higher value of voltage. voltage.
Insulated Case Circuit Breakers Circuit Breaker Envelope Size (Amperes)
Trip Types Power+
MicroVersaTrip Plus/PM MagneTrip
Molded Case Switch
Max IC @ 480V (kA)
Max Voltage Rating (ac)
X X X X X X
65 65 65 10 0 10 0 10 0 10 0 10 0 150 150 301 401 401 421 42 421 421
60 0 60 0 60 0 60 0 60 0 60 0 60 0 60 0 60 0 60 0 60 0 60 0 60 0 60 0 60 0 60 0
X X X X X X X
65 65 65 10 0 10 0 10 0 10 0 10 0 150 150 750 750 252 302 302 422 422 422 422
60 6 00 60 0 60 0 6 00 6 00 600 60 6 00 60 0 6 00 6 00 750 750 60 0 60 0 60 0 60 0 60 0 60 0 60 0
Max Voltage Max Frame Rating (dc) (Amperes)
Power Break II 80 0 1600 20 0 0 30 0 0 40 0 0 80 0 1600 20 0 0 30 0 0 40 0 0 80 0 1600 20 0 0 250 0 30 0 0 40 0 0
Standard
Hi-Break
Molded Case Switch
X X X X X X X X X X
X X X X X X X X X X
800 20 0 0 20 0 0 30 0 0 40 0 0 80 0 20 0 0 20 0 0 30 0 0 40 0 0 800 20 0 0 20 0 0 250 0 30 0 0 40 0 0
Power Break I
Standard
Hi-Break
Special Hi-Break
Molded Case Switch
80 0 1600 20 0 0 30 0 0 40 0 0 80 0 1600 20 0 0 30 0 0 40 0 0 30 0 0 40 0 0 80 0 1600 20 0 0 20 0 0 30 0 0 30 0 0 40 0 0
X X X X X X X X X X
X X X X X X X X X X X X
250 250 250 250 25 250 25 60 0 60 0 60 60 0 60 0 60 60 0 60 70 0 70 0
800 20 0 0 20 0 0 30 0 0 40 0 0 80 0 20 0 0 200 0 30 0 0 40 0 0 30 0 0 40 0 0 800 20 0 0 20 0 0 20 0 0 250 0 30 0 0 40 0 0
1Molded case switch ratings are short time @ 600Vac, not interrupting current. See page 5-13 for withstand ratings. 2
Molded case switch ratings are short time @ 600Vac, not interrupting current. See page 5-34 for withstand ratings.
distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
5-4
BuyLog Catalog
www.geelectrical.com
Rev. 12/04
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break II Circuit Breakers Features
S E R S E A K C A E D R E B T T A I L U U C S R I N I C
Power Break II Circuit Breakers The Insulated Case Circuit Breaker—GE pioneered the design and created the name in 1965. GE Power Break II insulated case circuit breakers are the latest in reliable, flexible and easy-to-use circuit protection. Power Break II circuit breakers are UL Listed, CSA and IEC-947-2 Certified for up to 200,000 amperes, at 240 volts rms symmetrical interrupting capacity without fuses or current limiters. These new insulated case circuit breakers rated 200-4000A can be applied on ac power systems through 600 volts. All breaker frames, except 4000A stationary, are UL Listed to carry 100% of their ampere rating continuously. All frames are suitable for reverse feeding.
5
All Power Break II circuit breakers are available in two levels of interrupting capacity—”standard break” and “Hi-Break” breakers. Each interrupting level is available in both stationary and draw-out construction, with a full complement of control and signaling accessories. Standard break breakers are designed to meet the majority of application requirements, calling for moderate levels of available short-circuit current. Hi-Break breakers are specially designed to withstand the stresses, and safely interrupt high levels of short-circuit current found in some applications (from 65 to 200 kA rms symmetrical amperes—depend- ing on voltage).
Greater Convenience and Operational Safety The controls and status indicators you need most are readily accessible. The flush-mounted handle, ON/OFF buttons, rating plug test receptacle, bell alarm reset buttons — with or without lockout — are easily reached and all are double-insulated from live compo- nents. And, for added security, a standard padlock device lets you prevent accidental or unauthorized closing of the breaker. Power Break II circuit breakers are versatile and designed for a wide variety of applications including temperature insensitive trip units, push-to-open and close control, charge-after-close operation, 3 cycle closing, UL listed (file E 11592) field installable accessories suitable for 50/60 Hz. All accessories and control wiring are prewired to dedicated, secondary terminal points on each breaker.
Quick, Error-Free Installation of Universal Accessories Drop-in bell alarm, bell alarm with manual reset lockout, shunt trip, shunt trip with lockout, and undervoltage release install in seconds. No special tools. No breaker disassembly. Just slide them into place. The modules are universal across all frame sizes and each is mechanically keyed to its compartment so you make the right connection, every time. These accessories are field installable and upgrad upgradable. able.
GE’s innovative, modular, drop-in accessories provide the ultimate customer solution for field customization:
UL Listed —Accessory combination (one each) shunt trip, undervoltage release, bell alarm (alarm only), bell alarm with lockout. —Rated 12-250 Vdc through 12-240 Vac, continuous duty. Complete installation in seconds without special tools, breaker disassembly or adjustment —The user can select how protective trip unit functions, the shunt trip (with or without lockout), and UVR accessories interface with the bell alarm and bell alarm with lockout accessories: An overcurrent, shunt trip, or UVR trip can be set to actuate the bell alarm or bell alarm with lockout. Any combination of output actions based on inputs can be selected. —Shunt trip and undervoltage trip targets are clearly displayed by the trip unit LCD. Pre-wired wire harness makes field installation a snap for: —Motor operator with remote charge indicator —Auxiliary switches, up to 12-stage maximum —Remote close solenoid
Additional field-installable accessories including: —Kirk Key locks (4 maximum) —Limited access ON/OFF cover —Mechanical operations counter —Door interlock —Walking beam interlock for stationary and draw-out breakers.
Ratings for Global Use —Performance ratings include IEC947-2 certification.
Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com Rev. 12/04
www.geelectrical.com
BuyLog Catalog
5-5
Prices and data subject to change without notice
Insulated Case Circuit Breakers
S E R S E A K C A E D R E B T T A I L U U C S R I N I C
5
Power Break II Circuit Breakers
Trip Target Module (Optional)
Trip Unit Features
View Button: Press the VIEW button to check the trip unit status. Reset Button: Press the RESET button to clear any target that is set.
Power+ Trip Unit Systems The Power+ trip unit system for Power Break II insulated case breakers consist of the trip unit, the trip actuator, current sensors and rating plugs. The term “trip unit system” applies to the combina- tion of these four components which form the solid-state circuit breaker tripping system. Power+ trip units provide a complete range of standard and optional overcurrent and ground-fault protective functions.
True RMS Sensing The Power+ trip unit continues to use GE’s proven technique of measuring true rms currents of both sinusoidal and harmonically distorted waveforms. The frequent sampling (48 times per cycle per phase) allows precise calculations of true rms current. The sampling rate allows waveform measure- ments up to the 11th harmonic. GE’s true rms sensing avoids potential underprotection or overprotection problems associated with peak- sensing tripping systems.
Accessory Integration Four accessories are integrated through the Power+ trip unit. Drop- in shunt trip (with or without lockout), bell alarms (with or without lockout) and the undervoltage release modules fit into keyed pock- ets. They operate through the trip units, and not through any external mechanisms. All accessory wiring is pre-wired to secondary termi- nals, and no user wiring is necessary. When activated, the shunt trip (with or without lockout) and undervoltage release modules send a signal to the trip unit to energize the trip actuator and open the breaker.
Battery check: Target modules use two standard, 3V, 16mm x 1.6mm, lithium batteries for viewing target information. Battery life depends upon use, but may be estimated at one year. When the batteries are energized, depressing the VIEW button will illuminate either a set target LED, i.e., LT or the BAT LED. Once target indicators are cleared, battery status is indicated by the BAT LED. Replacement batteries include Panasonic CR1616, Eveready E-CR1616BP, or Duracell DL1616B, which may be purchased commercially.
Long-time pickup: The long-time pickup indicator moves through two transitions. As the current in any phase reaches 95% of its setpoint; the LTPU LED begins to flash. As As current increases, flashing fre- quency increases, until 100% of the pickup point is reached. At that moment, the LTPU LED stays on continuously until the long-time delay times out. Once the breaker has tripped on long-time, the OVL target will be stored in memory. To view the trip, press the VIEW button. To clear the target, press the RESET button. Short-time and instantaneous trips: Short-time and instantaneous trips share the same trip target. The LTPU LED is not illuminated, since the time intervals between pickup and tripping are too short for either function. Once the breaker has tripped on short-time or instantaneous, the short target will be stored in memory. To view the trip, press the VIEW button. To clear the target, press the RESET button. Ground fault trip (Target0 (Target022 only): The trip target for a ground fault trip is the GF LED. To To view the trip, press the view button. To To clear the target, press press the RESET button. button. Health monitor: Trip unit health status “okay” is illustrated by slow blinking of the LTPU LED. It may be seen by depressing and holding the VIEW button. Sufficient power must be supplied to the trip unit via external test kit, power pack, or current transformers for the health monitor to be operational. Standard and Optional Protective Functions Standard and optional protective functions are available for Power+ trip units. The breaker settings are programmed in multiples of “X” (rating plug ampere values), “S” (current sensor ampere rating values), and “C” (the long-time setting in amperes—multiply long-time setting by rating plug ampere rating).
Standard —Adjustable Long-Time (L) Pickup, 0.5 - 1.0X, with four delay bands. —Adjustable Instantaneous (I) Pickup, 1.5 - 15X.1
Options —Overload, Short Circuit, and Short-Time local trip indicators with overload pickup warning and health monitor. —Adjustable Short-Time (S) Pickup, 1.5 - 9.0C, and delay (3 bands) with I 2 t ON/OFF selection. —Adjustable Ground Fault (G) Pickup, 0.2 - 0.6S, and delay 1 (3 ba bands nds)) wi with th I 2 t ON/OFF selection and trip indicator. —Upgradeable Ground Fault function with use of appropriate ground fault rating rating plug. 1Limited by breaker frame size above 2000A.
Power+ Trip Target Module
distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
5-6
BuyLog Catalog
www.geelectrical.com
Rev. 12/04
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break II Circuit Breakers Trip Unit Features
S E R S E A K C A E D R E B T T A I L U U C S R I N I C
Two Choices of Advanced, Digital Solid-State Trip Units Enhanced MicroVersaTrip Plus and MicroVersaTrip PM trip units give you two new ways to monitor and control the Power Break II breaker with unprecedented ease. Through the simple keypad, the trip unit lets you program and display a variety of functions including tripping characteristics, remote communications, status information and protective relaying, and allows integration with GE POWER LEADER Power Management Systems. The trip unit display also allows viewing of many standard metering parameters as well as pickup alarms, trip target indications and fault status information. Enhanced MicroVersaTrip Plus and MicroVersaTrip PM trip units continue to use GE’s proven technique of measuring true rms currents (and voltages for MicroVersaTrip PM trip units) of both sinusoidal and harmonically distorted waveforms. The frequent sampling (64 times per cycle) allows precise calculations of true rms current. The sampling rate allows waveform measurements up to the 31st harmonic to achieve accuracies of 99%. GE’s true rms sensing avoids potential underprotection or overprotection problems associated with peak-sensing tripping systems.
5
Enhanced MicroVersaTrip Plus and MicroVersaTrip PM Trip Units have been specifically designed to integrate with the extensive capabilities offered by Power Break II circuit breakers.
The enhanced trip unit design includes a wide range of functions and adds many new features:
UL Listed Field-Interchangeable
Features exclusive to MicroVersaT MicroVersaTrip rip PM Trip Units
Non-volatile trip targets display/Cold setup capability —Replaceable long-life batteries provide trip target indications and cold setup capability—without the need for external power or a battery pack.
Communications —All information can be viewed on the LCD display or communicated over a POWER LEADER Power Management Managem ent System network. network.
Trip operations counter —The number of long-time, short-time, instantaneous and ground fault trips are individually counted and displayed.
Demand/peak demand —The trip unit can display a rolling average of power demand and peak power demand at user-selected intervals from 5 to 60 min minutes utes..
Trip information —On overcurrent faults, the trip unit displays fault pickup, the type Local and remote metering of fault, the magnitude of the fault current and the phase the —Amps, volts, frequency fault occurred on. —Display indicates when a shunt trip or undervoltage release trip has opened the breaker.
New display —Ergonomic, 5-button keypad —New targets with international symbols —High-resolution LCD display for local 3-phase ammetering —New status and setup displays for greater ease of use —True rms sensing for accurate response to high harmonic con- tent waveforms for Long-Tim Long-Time, e, Short-Time, and Ground Fault protection. —50/60 Hz operation. —Interchangeable, UL Listed trip units and rating plugs with test set jack for TVRMS2 test set. —EMI immunity per ANSI C37.90.
—Real power, total power —Accumulated energy
Protective relays include: —Current and voltage unbalance —Overvoltage —Undervoltage —Power reversal —Power reversal direction setup
Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com Rev. 12/04
www.geelectrical.com
BuyLog Catalog
5-7
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break II Circuit Breakers S E R S E A K C A E D R E B T T A I L U U C S R I N I C
5
Trip Unit Characteristics
Power+ Trip Unit Characteristics Long-Time
Short-Time
Frame Max. Ampere Rating
Sensor Rating (Amperes) (S)
800
200, 400, 800
2.4, 4.9, 9.8, 20
1600
800, 1000, 1600
2.4, 4.9, 9.8, 20
2000
2000
3000
2500, 3000
1000, 2000, 2500, 3000
2.4, 4.9, 9.8, 20
4000
4000
4000
2.4, 4.9, 9.8, 20
Envelope Size
2000
Current Setting (C) (Pick-Up) Multiple Multipl e of Ratin Rating g Plug Ampe Amperes res (X) (X)
Pick-up (Multiple Delay Del ay 1 (Seconds 4 Bands) of C Current urrent Settin Setting) g) (C) (C)
0.5, 0.6, 0.7, 0.8, 0.9, 0.95 and 1.0
2.4, 4.9, 9.8, 20
Delay (Sec (Seconds onds 3 Bands Bands) ) 2
1
I T in .10, .21, .35 1.5, 2.0, 2.5, 3.0, 4.0, 5.0, 7.0, and 9.0
2
2
I T out .10, .21, .35
Power+ Trip Unit Characteristics (continued) Ground Fault Envelope Size
Adjustable Instantaneous Pick-Up without ST (Multiple of Rating Plug Amperes) (X)
Adjustable Instantaneous Pick-Up with ST (Multiple of Rating Plug Amperes) (X)
Pick-Up (Multiple of Sensor Sens or Am Ampe pere re Ra Rati ting ng))
1.5 thru 10.0
1.5 thru 15.0
0.20 thru 0.60
1.5 thru 10.0
1.5 thru 15.0
0.20 thru 0.60
1.5 thru 10.0
1.5 thru 15.0
0.20 thru 0.60
3000
1.5 thru 10.0
1.5 thru 13.0
0.20 thru 0.37
4000
1.5 thru 9.0
1.5 thru 9.0
0.20 thru 0.30
2000
Dela De lay y 3 (Seconds 3 Bands) I 2T in4 .10, .21, .35
I2 T out2 .10, .21, .35
Enhanced MicroVersaTrip Plus and PM Trip Unit Characteristics Long-Time Frame Max. Envelope Size Ampere Rating
Sensor Rating (Amperes) (S)
Current Setting (C) (Pick-Up) Mult Mu ltip iple le of of Rat Ratin ing g Plug Plug Amp Amper eres es (X) (X)
Short-Time Dela De lay y 2 (Seconds)
800
800
200, 400, 800
2.4, 4.9, 9.8, 20
1600
1600
800, 1000, 1600
2.4, 4.9, 9.8, 20
2000
2000
2000
2500
1000, 2000, 2500
3000
3000
4000
4000
3000 4000
2.4, 4.9, 9.8, 20
0.5 thru 1.0 in increments of 0.05
Pick-up (Multiple of Cu rr rr en en t Se tt tt in in g) g) ( C) C)
De la la y (S ec ec on on ds ds ) 2
1
I T in 0.40 1.5 thru 9.0 in increments of 0.5
2.4, 4.9, 9.8, 20
2
2
I T out .10, .21, .35
2.4, 4.9, 9.8, 20
Trip Unit Characteristics (continued) Adjustable Instantaneous Pick-Up with ST (Multiple of Rating Plug Amperes) (X)
800
1.5 thru 10.0 in 0.5 increments
1.5 thru 15.0 in 0.5 increments
0.20 thru 0.60 in increments of 0.01
1600
1.5 thru 10.0 in 0.5 increments
1.5 thru 15.0 in 0.5 increments
0.20 thru 0.60 in increments of 0.01
Envelope Size
High Range Instantaneous (Multiple of Frame Short-Time Rating) (H)
Ground Fault
Adjustable Instantaneous Pick-Up without ST (Multiple of Rating Plug Amperes) (X)
Pick-Up (Multiple of Sensor Ampere Rating)
0.20 thru 0.60 in increments of 0.01
Delay With I 2 T In Seconds
Delay 3 With I 2 T Out Seconds .10, .21, .35 .10, .21, .35
.44 at 200% of pick-up at lower limit of band
2000
1.5 thru 10.0 in 0.5 increments
1.5 thru 15.0 in 0.5 increments
3000
1.5 thru 10.0 in 0.5 increments
1.5 thru 13.0 in 0.5 increments
0.20 thru 0.37 in increments of 0.01
.10, .21, .35
4000
1.5 thru 9.0 in 0.5 increments
1.5 thru 9.0 in 0.5 increments
0.20 thru 0.30 in increments of 0.01
.10, .21, .35
1.0
1 Time delay shown at 600% of current setting at lower limit of band. 2 Time delay shown at lower limit of each band. All pick-up tolerances are 10%. ± 3 Time delay shown at lower limit of each band. Ground fault pick-up not to exceed 1200 amperes. 4 Time delay shown at 200% of pick-up at lower limit of band.
.10, .21, .35
X = Rating plug amps S = Sensor amp rating C = Long-time current setting (pick-up) H = Short-Time Rating
distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
5-8
BuyLog Catalog
www.geelectrical.com
Rev. 12/04
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break II Circuit Breakers Trip Unit Characteristics (continued)
Additional Features and Characteristics Exclusive to the Enhanced MicroVersaTrip PM Trip Unit 1 Trip Unit Suffix Function Communications
Description —POWER LE LEADER Co Communications Bu Bus Li Link
M (Metering)
P (Relaying)
PM (Metering & Relaying)
STD
STD
STD
STD
STD
STD
Amperes (A, kA)2
Selectable Phase Current ±2.5%
Voltage (V)
L-L or L-N Volts ±1.5%
•
•
Energy (kWh, MWh, GWh)
Total Energy Usage on Brkr ±4%
•
•
Real Power (kW/MW)
L-L or L-N Power ±4%
•
•
Total Power (kVA/MVA)
L-L or L-N Power ±4%
•
•
Frequency (Hz)
Circuit Frequency ± 1Hz
•
•
•
•
Demand & Peak Demand (kW) Under Voltage Trip
—Adjustable pickup 50-90% —Adjustable delay, 1-15 seconds OFF
•
•
Over Voltage Trip
—Adjustable pickup, 110-150% —Adjustable delay, 1-15 seconds OFF
•
•
Voltage Unbalance
—Adjustable pickup, 10-50% —Adjustable delay, 1-15 seconds OFF
•
•
Current Unbalance
—Adjustable pickup, 10-50% —Adjustable delay, 1-15 seconds OFF
•
•
—Adjustable pickup, 10-990 kW —Adjustable delay, 1-15 seconds OFF —Power Reversal Direction
•
•
Power Reversal
•
•
1 MicroVers aTrip PM™ functions req uire 24 Vdc control power. 2 Ampere reading also standard on MicroVersaTrip Plus trip units.
Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com Rev. 12/04
www.geelectrical.com
BuyLog Catalog
5-9
S E R S E A K C A E D R E B T T A I L U U C S R I N I C
5
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break II Circuit Breakers S E R S E A K C A E D R E B T T A I L U U C S R I N I C
Product Number Nomenclature System
Power Break II Circuit Breaker Product Numbers
5
1High-range instantaneous sensors only available on MicroVersaT MicroVersaTrip rip Plus and MicroVersaTrip PM units.
NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.
Accessory Product Numbers 2
2 Device Product Number requires an extender “R” for field installable kit version only.
NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.
distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
5-10
BuyLog Catalog
www.geelectrical.com
Rev. 12/04
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break II Circuit Breakers Product Number Nomenclature System
S E R S E A K C A E D R E B T T A I L U U C S R I N I C
Power+ Trip Unit Product Numbers 1
5
1Device Product Number requires an extender “R” for field installable kit version only.
NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.
Power+ Rating Plug Product Numbers
Power+ Target Module Product Numbers TARGET00 TAR GET00 = Blank insert for Target Module TARGET01 = Target Module without ground fault target TARGET02 = Target Module with ground fault target NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.
Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com Rev. 12/04
www.geelectrical.com
BuyLog Catalog
5-11
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break II Circuit Breakers S E R S E A K C A E D R E B T T A I L U U C S R I N I C
Product Number Nomenclature System
MicroVersaTrip MicroVersaT rip Plus and MicroVersaT MicroVersaTrip rip PM Trip Unit Product Produ ct Numbers 1
5
1Device Product Number requires an extender “R” for field installable kit version only.
NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.
Rating Plug Product Numbers (MicroVersaTripPlus (MicroVersaTripPlus and PM)
NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.
distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
5-12
BuyLog Catalog
www.geelectrical.com
Rev. 12/04
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break II Circuit Breakers Interrupting Capacity and Withstand Ratings
S E R S E A K C A E D R E B T T A I L U U C S R I N I C
The interruption ratings and voltages shown in the table are maxi- mum ratings. A circuit breaker of the type given in the left-hand column may be applied at the given circuit voltage in any electrical distribution system where the available fault current at the load terminals of the breaker does not exceed the value in the table. That circuit breaker type may also be applied at intermediate values of circuit voltage provided the available fault current at the load terminals of the breaker does not exceed the value in the table for the higher value of voltage.
5
Power Break II Interrupting Capacity and Short-time Ratings–rms Symmetrical kA Frame
800A
1600 to 2000A
2500-3000A
4000A
UL 489 Ratings, 50/60 Hz Standard 240V
65
85
100
100
480V
65
65
100
100
600V
42
50
85
85
240V
100
125
200
200
480V
100
100
150
150
600V
65
65
100
100
25
40
42
42
Hi-Break
Short Time1 (0.5 sec)
IEC-947-2 Ratings 415, 50/60 Hz ICU
—
75
752
85
ICS
—
56
452
25
ICW (1 sec)
—
40
502
50
1 Applies to high range instantaneous or "H" option. 2 Must use 4000A construction.
Complete dimensions and weight information can be found in the Power Break II application guide GET-8052. GET-8052.
Stationary and Draw-out Switch Withstand Ratings—rms Symmetrical kA
Switch Frame (Amperes)
Short-time Rating, rms Sym Amperes @ 600 Vac Max., 500 ms Max.
Max axii mu mu m Sh Sho o rt rt Ci Ci rc rc ui ui t Wi Witt hs hs tan tand d Rat Ratii ng ng When Wh en Pr Prot otec ecte ted d By By Pow Power er Br Brea eak k IIII Cir Circu cuit it Br Brea eake kers rs Breaker Frame Size (Amperes)
Standard Break PB II Circuit Breaker 240 Vac 480 Vac 600 Vac
Suii tab Su tabll e o n 20 200, 0,00 000 0 rm rms Sym Sym A mp mp er ere Fau Faull t Ci Cirr cu cu it it When Wh en Pr Prot otec ecte ted d by Cl Clas ass s L Fu Fuse ses s As Fo Foll llow ows s
Hi-Break PB II Circuit Breaker 240 Vac 480 Vac 600 Vac
Line Side Max. Fuse Ampere Rating
Load Side Max. Fuse Ampere Rating
80 0
30
800
65
65
50
100
10 0
65
20 00
80 0
160 0
40
1600
65
65
50
125
10 0
65
2500
160 0
200 0
40
2000
65
65
50
125
10 0
65
2500
20 00
2500
42
250 0
10 0
100
85
200
150
100
2500
2500
300 0
42
3000
10 0
100
85
200
150
100
40 00
30 00
400 0
42
4000
10 0
100
85
200
150
100
40 00
40 00
Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com Rev. 12/04
www.geelectrical.com
BuyLog Catalog
5-13
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break II Circuit Breakers S E R S E A K C A E D R E B T T A I L U U C S R I N I C
5
How To Order
How To Order All Power Break II circuit breakers are available in two levels of interrupting capacity – “Standard break” and “Hi-Break” breakers. Each interrupting level is available in both stationary and draw-out construction, are suitable for reverse feed, and have a full comple- ment of control and signaling accessories. Power Break II circuit breaker frames are factory configured for either the enhanced MicroVersaTrip MicroVersaT rip Plus or MicroVersaTrip PM trip units. u nits.
1. Determine the type of frame; stationary or draw-out. 2. Determine the required breaker frame, interrupting current level, short-time rating and load requirements. Select the appropriate frame product number and list price on page 5-15. 3. Select the basic enhanced MicroVersaTrip unit to match frame ampere rating from page 5-17. SSF20B220
4. Select and price the trip unit suffix from pages 5-17 and 5-18 to match the required trip functions. Refer to page 5-8 for trip unit characteristics. The trip unit will be installed in the frame. 5. Select and price the required rating plug from page 5-19. The sensor ratingplugs of thewill frame must match the sensor rating of the plug. Rating be shipped separately.
6. Internal accessories should be priced separately from pages 5-21 through 5-26. Accessories will be installed in the frame. Order internal accessories accessories ending with “R” for field installa installation tion separately. separately. 7. Select and price externally mounted accessories, such as, push- button cover, key interlock provisions, lug kits and T-studs from pages 5-25 through 5-28. 8. If a draw-out breaker is required, the draw-out substructure is priced separately from page 5-29. The draw-out breaker is shipped including breaker, trip unit, and breaker secondary disconnects for control and accessory wiring. The substructure secondary discon- nects are priced separately from page 5-29.
Draw-out in Substructure
9. Order substructure accessories, such as shutters, mechanical interlocks, racking tool and lifting bar from page 5-30.
Pricing Example—Draw-out Breaker
Pricing Example–Stationary Breaker
1600 ampere draw-out frame, 100 kA, 480functions V IC rating, 1000 ampere sensor, 600 ampere rating plug, trip unit including long-time (L), short-time (S), high range instantaneous (H), factory installed accessories including: 120 Vac electric (motor) operator; 24 Vdc remote close solenoid; 24 Vdc shunt trip; draw-out substructure; draw-out secondary disconnect; draw-out shutter.
GO-245A
2000 ampere stationary frame, 65 kA, 480 V IC rating, 2000 ampere sensor, 800 ampere rating plug, trip unit functions including long-time (L), short-time (S), Instantaneous (I), MicroVersaTrip PM trip unit, field installed 120 Vac electric (motor) operator, 24 Vdc remote close solenoid, 24 Vdc undervoltage release module. Description
Product Number
List Price
Description
GO-245A
Product Number
List Price
Frame
SHD16B210H
$10182.00
Trip Unit and Suffix Adder
B210LSH
$1350.00
Rating Plug
TR10B600
$89.00
Frame
SSF20B220
$7790.00
Electric Operator
SPE120
$1838.00 1
Trip Unit and Suffix Adder
B220LSIPM
$2283.00
Remote Close Solenoid
SPRCS024
$315.00 1
Rating Plug
TR20B800
Shunt Trip
SPST024
$328.00 1
Electric Op Operator-field in installed
SPE120R
$1671.00 1
Drawout Substructure
SPHDOS16
$1403.00 1
SPRC SP RCS0 S024 24R R
$286.00 1
Sub Su b str stru u ctu cturr e Se Sec c on on dar dary y Di Di sc sc on on nec nectt
SPD SP D OSD OSD36 36S S
$283.00 1
S PUV PUV0 0 24 24 DC DC R
$301.00 1
Substructure Shutter Kit
SPDSS20
$501.00 1
Remo Re mote te Cl Clos ose e So Sole leno noidid-fi fiel eld d ins insta talle lled d Unde Un derv rvol oltt age age R ele elea a se se -f -f ie ie ld ld ins instt all alle ed
$89.00
1 GO-245B
distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
5-14
BuyLog Catalog
www.geelectrical.com
Rev. 12/04
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break II Circuit Breakers Frame
S E R S E A K C A E D R E B T T A I L U U C S R I N I C
5
Basic Frame Selection—Stationary Circuit Breaker Envelope Size (Amperes)
800
1600
2000
Circuit Breaker Frame Size (Amperes)
800
1600
2000
GO-245A Standard Break
Current Sensor (Amperes) 200
SSF08*202,H
$6006.00
SHF08*202,H
$6500.00
400
SSF08*204,H
$6006.00
SHF08*204,H
$6500.00
800
SSF08*208,H
$6006.00
SHF08*208,H
$6500.00
800
SSF16*208,H
$7342.00
SHF16*208,H
$8165.00
1 00 00 0
S SF SF 16 16* 21 21 0, 0, H
$7342.00
SHF16*210,H
$8165.00
1 60 60 0
S SF SF 16 16* 21 21 6, 6, H
$7342.00
SHF16*216,H
$8165.00
2000
SSF20*220,H
$7790.00
SHF20*220,H
$9124.00
SSF25*210,H
$8569.00
SHF25*210,H
$10035.00
SSB25*210,H
$8569.00
SHB25*210,H
$10035.00
SSF25*220,H
$8569.00
SHF25*220,H
$10035.00
SSB25*220,H
$8569.00
SHB25*220,H
$10035.00
SSF25*325,H
$15107.00
SHF25*325,H
$18930.00
SSB25*325,H
$15107.00
SHB25*325,H
$18930.00
SSF30*330,H
$19229.00
SHF30*330,H
$24101.00
SSB30*330,H
$19229.00
SHB30*330,H
$24101.00
SHF40*440 3
$38691.00
1000
2500
2000
3000 2500
3000 4000
4000
Hi-Break
Product 1 Number
3000 4000
SSF40*440
3
Product 1 Number
List Price 2
$31714.00
Basic Frame Selection—Draw-out (without substructure) Circuit Breaker
Circuit Breaker
Envelope Size (Amperes)
Frame Size (Amperes)
800
1600
2000
GO-245A
Standard Break
Hi-Break
Current Sensor (Amperes)
Product 1 Product 1 Number
200
SSD08*202,H
$7085.00
SHD08*202,H
$7597.00
400
SSD08*204,H
$7085.00
SHD08*204,H
$7597.00
800
SSD08*208,H
$7085.00
SHD08*208,H
$7597.00
800
SSD16*208,H
$9205.00
SHD16*208,H
$10182.00
10 00 00
SS D1 D16 *2 *2 10 10 ,H ,H
$9205.00
SHD16*210,H
$10182.00
16 00 00
SS D1 D16 *2 *2 16 16 ,H ,H
$9205.00
SHD16*216,H
$10182.00
2000
SSD20*220,H
$9604.00
SHD20*220,H
$11118.00
10 00 00
SS D2 D25 *2 *2 10 10 ,H ,H
$10563.00
SHD25*210,H
$12229.00
20 00 00
SS D2 D25 *2 *2 20 20 ,H ,H
$10563.00
SHD25*220,H
$12229.00
25 00 00
SS D2 D25 *3 *3 25 25 ,H ,H
$18234.00
SHD25*325,H
$22431.00
3000
3000
SSD30*330,H
$22819.00
SHD30*330,H
$28125.00
4000
4000
SSD40*440,H
$38007.00
SHD40*440,H
$46116.00
800
1600
2000
2500 3000
4000
List Price 2
List Price 2
Product 1 Product 1 Number
List Price 2
1
Add 'H' suffix to product number for high-range instantaneous protection. Price adder is on trip unit only. High-range instantaneous feature available only with MicroVersaTrip Plus™ or MicroVersaTrip PM™.
2
Prices shown include basic "Power+ LI" trip unit but do not include rating plug.
3 80%
rated. *Replace * with B for MicroVersa Trip Plus or PM trip unit: or D for Power+™ trip unit.
Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com Rev. 12/04
www.geelectrical.com
BuyLog Catalog
5-15
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break II Circuit Breakers S E R S E A K C A E D R E B T T A I L U U C S R I N I C
5
Stationary and Draw-out Switch Selection How To Order How to Order
Power Break II Rating Plug Selection
1. Choose a frame from the Molded Case Switch Frame tables below 2. Select a Control Unit from the Control Unit table below. The sensor rating of the control unit should match the sensor rating of the switch. Choose a control unit with suffix T2 to get ground fault target indication.
Basic Control Unit
Current Rating (Amperes)
D208
3. Select a rating plug from the table to the right. 4. Select all other accessories just as for any Power Break II Circuit Breaker.
D210
Molded Case Switch Frames—Stationary
D216
GO-245D
Switch En Envelope Size Si ze (A (Am m pe pe re re s) s)
Switch Fr Frame Size Si ze (A (Am m pe pe re re s) s)
Current Se Sensor Rati Ra ting ng (A (Am m pe pe re re s) s)
Product Num Nu m be be r
80 0 160 0 20 0 0
80 0 160 0 20 0 0
80 0 160 0 20 0 0
SSF08Y208 SSF16Y216 SSF20Y220 SSF25Y325 SSB25Y325 SSF30Y330 SSB30Y330
250 0 3000
250 0
30 0 0
30 0 0
L ist ist Pr Pric ice e
$3119.00
$4099.00 $4609.00
$7334.00
$7334.00
$12411.00
$10204.00
Molded Case Switch Frames—Draw-out 1
GO-245D
Switch En Envelope Size (Amperes)
Switch Fr Frame Size (Amperes)
Current Se Sensor Rating (Amperes)
Product Number
80 0 160 0 20 0 0
80 0 160 0 20 0 0 250 0 30 0 0 40 0 0
80 0 160 0 20 0 0 250 0 30 0 0 40 0 0
SSD08Y208 SSD16Y216 SSD20Y220 SSD25Y325 SSD30Y330 SSD40Y440
3000 40 0 0
D220
D325
D330
List Price
$4061.00
$5913.00
D440
$6426.00
$10204.00
$15864.00
$25526.00
40 0 450 50 0 50 60 0 70 0 80 0 60 0 80 0 10 0 0 80 0 10 0 0 110 0 120 0 160 0 10 0 0 120 0 150 0 160 0 20 0 0 160 0 20 0 0 250 0 20 0 0 250 0 30 0 0 160 0 20 0 0 250 0 30 0 0 360 0 40 0 0
GO-245A
Powe Po werr + Stand Standar ard d Rating Plug List Price $89.0 0
Powe Po werr + Groun Ground d Faul Fault t Rating Plug List Price $747.00
TR8C40 0 TR8C450 TR8C50 0 TR8C60 0 TR8C70 0 TR8C80 0 TR10C60 0 TR10C80 0 TR10C10 0 0 TR16C80 0 TR16C10 0 0 TR16C110 0 TR16C120 0 TR16C160 0 TR20C10 0 0 TR20C120 0 TR20C150 0 TR20C160 0 TR20C20 0 0 TR25C160 0 TR25C20 0 0 TR25C250 0 TR30C20 0 0 TR30C250 0 TR30C30 0 0 TR40C160 0 TR40C20 0 0 TR40C250 0 TR40C30 0 0 TR40C360 0 TR40C40 0 0
TR8C40 0GF TR8C450GF TR8C50 0GF TR8C60 0GF TR8C70 0GF TR8C80 0GF TR10C60 0GF TR10C80 0GF TR10C10 0 0GF TR16C80 0GF TR16C10 0 0GF TR16C110 0GF TR16C120 0GF TR16C160 0GF TR20C10 0 0GF TR20C120 0GF TR20C150 0GF TR20C160 0GF TR20C20 0 0GF TR25C160 0GF TR25C20 0 0GF TR25C250 0GF TR30C20 0 0GF TR30C250 0GF TR30C30 0 0GF TR40C160 0GF TR40C20 0 0GF TR40C250 0GF TR40C30 0 0GF TR40C360 0GF TR40C40 0 0GF
1Use only with Hi-Break draw-out substructure.
Ordering Example Control Units Switch Envelope Size (Amperes)
Switch Frame Size (Amperes)
Sensor (Amperes)
80 0
80 0
80 0
160 0
160 0
1000 1600
20 0 0
20 0 0
20 0 0 1000
250 0 3000
20 0 0 2500
40 0 0
30 0 0
30 0 0
40 0 0
40 0 0
Product Number
D208 D208T2 D210 D210T2 D216 D216T2 D220 D220T2 D210 D210T2 D220 D220T2 D325 D325T2 D330 D330T2 D440 D440T2
List Price Adder, GO-245A
$0.00
$160.00
$0.00
$160.00
$0.00
$160.00 $0.00
$160.00
$0.00
$160.00
$0.00
$160.00
$0.00
$160.00
$0.00
$160.00
$0.00
$160.00
1600 ampere drawout switch; field installed 120 Vac electric (motor) operator; 24 Vdc remote close solenoid; 24 Vdc shunt trip; drawout substructure; drawout secondary disconnect; drawout shutter. Description
Product Number
Frame Control Unit Rating Plug Electric Operator
SSD16Y216 D216 TR16C160 0 SPE120
Remote Close Solenoid Shunt Trip Drawout Substructure Substr Sub struct ucture ure Se Secon condar dary y Disc Disconn onnect ect Substructure Shutter Kit
SPRCS024 SPST024 SPHDOS16 SPDOSD SPD OSD36S 36S SPDSS20
List Price $5913.001
$0.002
$89.002 $1838.003
3
$315.00 $328.003 $1403.003
$283.003 $501.003
1GO-245D 2GO-245A 3GO-245B
distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
5-16
BuyLog Catalog
www.geelectrical.com
Rev. 12/04
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break II Circuit Breakers Trip Unit Selection How To Order
Example:
How to Order 1. Determine the basic trip unit product number.
1600 Ampere frame, 1000 ampere sensor, Long-time (L). Short-time (S), Instantaneous (I), MicroVersaTrip PM with metering only. Order B210LSIM ( List List price adder: $1,733.00, GO-245A) . The replace- ment trip unit product number would be B210LSIMR.
2. Determine the type of trip unit, Power+, MicroVersaTrip MicroVersaTrip Plus or MicroVersaTrip MicroVersaT rip PM trip unit.
3. Select the trip unit suffix representing the protection function to
5
complete trip unit product number.
4. Determine list price adder to breaker frame list price on page 5-15. 5. Order rating plug separately. Pricing does not include rating plug plu g pri price. ce.
6. For replacement trip units, add suffix “R”. Check Elitenet for List Price and GO schedule.
Power Break II Trip Unit Suffix Power+ Trip Unit Suffix Selection Trip Unit Suffix 1
List Price Adder, GO-245A
LI
Basic Trip Unit Selection
Trip Indicators L/ST/l 1
Adjustable Instantaneous
No Price Adder
GF 2
—
Long-Time (L)
Short-Time (ST)
•
—
•
—
•
—
•
LIT1
$140.00
•
LIT2
$160.00
•
•
•
$683.00
—
—
•
•
•
—
•
•
•
•
•
•
•
LSI
LSIT1
$823.00
•
LSIT2
$843.00
•
Frame Size (Amperes)
Frame Rating (Amperes)
800
800
Inst. (l)
—
—
•
Sensor (Amperes)
Power+™ Trip Units
Enhanced MicroVersaTrip Plus™ and MicroVersaTrip PM™ Trip Units
200
D202
B202
400
D204
B204
800
D208
B208
800
D208
B208
1000
D210
B210
1600
D216
B216
2000
D220
B220
1000
D210
B210
2000
D220
B220
1600 1600-2000
2000
1
For high-range instantaneous or zone selective interlocking select MicroVersaTrip Plus or PM trip units. 2 For ground fault-protection, select appropriate rating plug.
2500 2500-3000
4000
2500
D325
B325
3000
3000
D330
B330
4000
4000
D440
B440
MicroVersaTrip MicroVersaT rip Plus with Selectable Phase Ammeter—Trip Indicators Standard Trip Unit Suffix 3
List Price Adder, GO-245A 3
Trip Indicators
Selectable Phase Ammeter
Long-Time (L)
Short-Time (ST)
Inst. (I)
High Inst. (H)
Ground Fault (G) 4
GF Zone Interlock (Z1) 5
GF/ST Zone Interlock (Z2) 5
Adjustable Instantaneous LI LIG
$300.00
•
•
•
$958.00
•
•
•
$1250.00
•
•
•
$983.00
•
•
•
•
•
$1640.00
•
•
•
•
•
•
LIGZ1 LSI LSIG
•
•
•
•
•
LSIGZ1
$1933.00
•
•
•
•
•
•
LSIGZ2
$2225.00
•
•
•
•
•
•
$1350.00
•
•
•
•
•
•
• •
Fixed High Range Instantaneous 6 LSH
$2008.00
•
•
•
•
•
•
LSHGZ1
$2300.00
•
•
•
•
•
•
LSHGZ2
$2593.00
•
•
•
•
•
•
LSHG
• •
3
Add suffix to basic trip unit product number. Make List Price Addition for trip unit suffix.. For single-phase 3 wire or 3-phase, 4-wire applications, order appropriate neutral current sensor and price separately, page 5-20. Defeatable Ground Fault (not UL Listed) is available. Use code GD in place of G. Add List Price $250.00, GO-245A, to the price of the trip unit. 5 Requires purchase of Zone Selective Interlock module(s) Type TIM1 (120 Vac control voltage). List Price $402.00, GO-245B. 6 Not available on 4000A stationary breaker frame. 4
Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com Rev. 12/04
www.geelectrical.com
S E R S E A K C A E D R E B T T A I L U U C S R I N I C
BuyLog Catalog
5-17
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break II Circuit Breakers S E R S E A K C A E D R E B T T A I L U U C S R I N I C
Trip Unit Selection (continued)
MicroVersaTrip MicroVersaT rip PM with Metering and Communications—T Communications—Trip rip Indicators Standard Trip Unit Suffix 1
List Price Adder, GO-245A1
Trip Indicators
Selectable Phase Ammeter
Long-Time (L)
Short-Time (ST)
Inst. (I)
High Inst. (H)
Ground Fault (G) 2
GF Zone Interlock (Z1) 3
GF/ST Zone Interlock (Z2) 3
Adjustable Instantaneous
LIM
$1050.00
LIGM
LIGZ1M
5
LSIM
•
•
•
•
$1708.00
•
•
•
•
•
$2000.00
•
•
•
•
•
$1733.00
•
•
•
•
•
$2390.00
•
•
•
•
•
•
LSIGZ1M
$2683.00
•
•
•
•
•
•
LSIGZ2M
$2975.00
•
•
•
•
•
•
LSIGM
•
• •
Fixed High Range Instantaneous 4
LSHM
LSHGM
$2100.00
•
•
•
•
•
$2758.00
•
•
•
•
•
•
LSHGZ1M
$3050.00
•
•
•
•
•
•
LSHGZ2M
$3343.00
•
•
•
•
•
•
• •
MicroVersaTrip MicroVersaT rip PM with Protective Relays and Communications—T Communications—Trip rip Indicators Standard Trip Unit Suffix 1
List Price Adder, GO-245A 1
Long-Time (L)
Short-Time (ST)
Inst. (I)
High Inst. (H)
Ground Fault (G) 2
Trip Indicators
Selectable Phase Ammeter
•
•
•
•
$1508.00 $1800.00
•
•
•
•
•
•
•
•
•
•
$1533.00
•
•
•
•
•
$2190.00
•
•
•
•
•
•
•
•
•
•
•
•
•
GF Zone Interlock (Z1) 3
GF/ST Zone Interlock (Z2) 3
Adjustable Instantaneous LIP
LIGP
$850.00
LIGZ1P LSIP
LSIGP
LSIGZ1P
$2483.00
•
LSIGZ2P
$2775.00
•
•
•
•
$1900.00
•
•
•
•
•
•
• •
Fixed High Range Instantaneous 4 LSHP
$2558.00
•
•
•
•
•
•
LSHGZ1P
$2850.00
•
•
•
•
•
•
LSHGZ2P
$3143.00
•
•
•
•
•
•
LSHGP
• •
MicroVersaTrip MicroVersaT rip PM with Metering, Protective Relays and Communications—T Communications—Trip rip Indicators Standard Trip Unit Suffix 1
List Price Adder, GO-245A 1
Trip Indicators
Selectable Phase Ammeter
Long-Time (L)
Short-Time (ST)
Inst. (I)
High Inst. (H)
Ground Fault (G) 2
GF Zone Interlock (Z1) 3
GF/ST Zone Interlock (Z2) 3
Adjustable Instantaneous LIPM
LIGPM
$1600.00
LIGZ1PM LSIPM LSIGPM
•
•
•
•
$2288.00
•
•
•
•
•
$2550.00
•
•
•
•
•
$2283.00
•
•
•
•
•
$2940.00
•
•
•
•
•
•
LSIGZ1PM
$3233.00
•
•
•
•
•
•
LSIGZ2PM
$3525.00
•
•
•
•
•
•
$2650.00
•
•
•
•
•
$3308.00
•
•
•
•
•
•
$3600.00
•
•
•
•
•
•
$3893.00
•
•
•
•
•
•
•
• •
Fixed High Range Instantaneous 4 LSHPM LSHGPM LSHGZ1PM LSHGZ2PM
• •
1
Add suffix to basic trip unit product number. Make List Price Addition for trip unit suffix.. For single-phase 3 wire or 3-phase, 4-wire applications, order appropriate neutral current sensor and price separately, page 5-20. Defeatable Ground Fault (not UL Listed) is available. Use code GD in place of G. Add List price $250.00, GO-245A, to GO-245A, to the price of the trip unit. 3 Requires purchase of Zone Selective Interlock module(s) Type TIM1 (120 Vac control voltage). List Price $402.00, GO-245B. 4 Not available on 4000A stationary breaker frame. 2
distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
5-18
BuyLog Catalog
www.geelectrical.com
Rev. 12/04
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break II Circuit Breakers Enhanced MicroVersaTrip, Rating Plug Selection
Power Break II Rating Plug Selection
Power+ Trip Unit Standard FS raizm ee S Rean tisnogr CRuartrienngt (Amperes) (Amperes) (Amperes) 20 0
800 400
80 0-1600
80 0
1000
1600
1600
200 0
20 00
1000
2500
200 0
2500
300 0
30 00
400 0
400 0
100 150 200 150 200 225 250 300 400 300 400 450 500 600 700 800 400 600 800
Ra Ltisint gPrPiclueg ,s $89.00
GO-245A Power+ Trip U ni nit Gr Ground Fault Rating LisPtluPgrisce, $747.0 0
Enhanced MicroVersaTrip Plus and Enhanc ed MicroVer sa saTrip PM PM Trip Unit Ra Ltisint gPrPiclueg, s $89.0 0
TR2C100 TR2C150 TR2C20 0 – TR4C20 0 TR4C225 TR4C250 TR4C30 0 TR4C40 0 – TR8C40 0 TR8C450 TR8C50 0 TR8C60 0 TR8C70 0 TR8C80 0 – TR10C600 TR10C800
TR2C10 0GF TR2C150GF TR2C200GF – TR4C200GF TR4C225GF TR4C250GF TR4C300GF TR4C400GF – TR8C400GF TR8C450GF TR8C500GF TR8C600GF TR8C700GF TR8C800GF – TR10C600GF TR10C800GF
TR2B100 TR2B150 TR2B200 TR48150 TR48200 TR48225 TR48250 TR48300 TR48400 TR8B300 TR8B400 TR8B450 TR8B500 TR8B600 TR8B700 TR8B800 TR10B400 TR10B600 TR10B800
10 00 00 600 800 10 00 00 110 0 120 0 160 0 750 800 10 00 00 1200 150 0 160 0 20 00 00 400 600 800 10 00 00 750 800 10 00 00 1200
TR10C10 00 00 – TR16C80 0 TR16C10 00 00 TR 16 16C 110 0 TR16C120 0 TR16C160 0 – – TR20C10 00 00 TR20C1200 TR20C150 0 TR20C160 0 TR20C20 00 00 – TR10C600 TR10C800 TR10C10 00 00 – – TR10C10 00 00 TR10C120 0
TR10C10 00 00GF – TR16C800GF TR16C10 00 00GF TR16 C1 C110 0G 0GF TR16C120 0G 0GF TR16C160 0G 0GF – – TR20C10 00 00GF TR20C120 0GF TR20C150 0G 0GF TR20C160 0G 0GF TR20C20 00 00GF – TR20C60 0GF TR20C80 0GF TR20C10 00 00GF – – TR10C10 00 00GF TR10C1200GF
TR10B10 00 00 TR16B60 0 TR16B80 0 TR16B10 00 00 TR 16 16B 110 0 TR16B120 0 TR16B160 0 TR20B750 TR20B800 TR20B10 00 00 TR20B1200 TR20B150 0 TR20B160 0 TR20B20 00 00 TR10B400 TR10B600 TR10B800 TR10B10 00 00 TR20B750 TR20B800 TR20B10 00 00 TR20B1200
150 0 160 0 20 00 00 160 0 2000 250 0 1200 1600 200 0 250 0 30 00 00 160 0 20 00 00 250 0 30 00 00 360 0 40 00 00
TR10C150 0 TR10C160 0 TR10C20 00 00 TR25C160 0 TR25C200 0 TR25C250 0 – – TR30C200 0 TR30C250 0 TR30C30 00 00 TR40C160 0 TR40C20 00 00 TR40C250 0 TR40C30 00 00 TR40C360 0 TR40C40 00 00
TR10C150 0G 0GF TR10C160 0G 0GF TR10C20 00 00GF TR25C160 0G 0GF TR25C20 00 00GF TR25C250 0G 0GF – – TR30C3000GF TR30C250 0G 0GF TR30C30 00 00GF TR40C160 0G 0GF TR40C20 00 00GF TR40C250 0G 0GF TR40C30 00 00GF TR40C360 0G 0GF TR40C40 00 00GF
TR20B150 0 TR20B160 0 TR20B20 00 00 TR25B160 0 TR25B20 00 00 TR25B250 0 TR30B1200 TR30B1600 TR30B20 00 TR30B250 0 TR30B30 00 00 TR40B160 0 TR40B20 00 00 TR40B250 0 TR40B30 00 00 TR40B360 0 TR40B40 00 00
Power+ Target Module
GO-245A
Power+ trip units are designed to accept an optional field-installable target module. The target module indicates long-time pickup, battery status, trip unit health status, and whether a breaker trip was caused by an overload, a short circuit or a ground fault. Target modules are available with or without ground fault indication. Trip Indicator L/ST/1 Ground Fault – – • – • •
Product Number TARGET00 TARGET0 TA RGET01 1 TARGET02 TARG ET02
Power+ Trip Target Module
for a list of additional product-related publications distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
www.geelectrical.com
MicroVersaTrip and MicroVersaTrip PM Rating Plug
Publications and Reference: See Section 21
Rev. 12/04
BuyLog Catalog
5-19
List Price $60.00 $140.00 $160.00
S E R S E A K C A E D R E B T T A I L U U C S R I N I C
5
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break II Circuit Breakers S E R S E A K C A E D R E B T T A I L U U C S R I N I C
Neutral Current Sensors and POWER LEADER Accessories
Neutral Current Sensors 1 Breaker Frame (Amperes)
Neutra Neut rall Se Se nso nsor r Rating or Tap Settings (A (Amperes)
200 400 400 800 1000 1000 1600 1600 200 0 1000 1000 1000 1000 200 0 250 0 300 0 400 0
200 400/200 600/30 02 800/400 800/40 02 10 00/50 0 120 0/60 02 1600/100 0 2000/10 00 800/40 02 10 00/50 0 120 0/60 02 160 0/10002 2000/1200 2500/1800 30 00/2400 40 00/3000
800
5
800-1600 1600
GO-245B
C irc ircui uitt Bre Brea a ke ke r Sensor Rating (Amperes)
2000
3000
4000
Product Number
List Pr Price
TSVG302 TSVG304A TSVG306A TSVG308A TSVG808A TSVG810A TSVG812A TSVG816A TSVG820A TSVG808A TSVG810A TSVG812A TSVG816A TSVG820A TSVG825A TSVG830A TSVG940A
$266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00
1Match neutral current sensor rating (or tap setting) to circuit breaker sensor rating. 2 For use with multiple source ground fault protection schemes. Rating does not match
MicroVersaTrip MicroVersaT rip Plus or PM frame sensor.
MicroVersaTrip Portable Test Kit
Product Number
Portable Test Kit
TVRMS2
Power supply for furnishing 24Vdc control power for MicroVersaTrip Plus and PM trip units. Two versions are available: a 1.5 ampere version with AC and DC input voltages and a 0.8 ampere version capable of operating from 120/230Vac. Both power supplies have inherent transient protection circuits. Description
System Requirements (price separately)
1.5 ampere power supply Price one PLPS4G01 for each eac h lin line-up e-up.. 45 trip uni units ts and 100 ft. maxi maximum mum..
Input Inp ut pow power er,, 100V 100VA A (85-265Vac (85-265V ac or 100100-370V 370Vdc) dc)
GO-245B
Product Number
List Price
PLPS4G0 PLP S4G01 1 $1250.00
Reference Instructions
GEH-6492
POWER LEADER Voltage Conditioner
G0-104A
Conditions and scales 120Vac to 1.76 Vac for use by the trip unit for voltage sensing. Provides transient protection. Voltage conditioners require isolation PTs PTs.. Description
System Re R equirements (price separately)
Supplies isolated bus voltage vol tage sig signal nal to MicroVersaTrip PM trip tr ip un unit its. s.
One set of 3 vol voltage tage con conditi ditioner oners s required for each voltage sensing loca lo cati tion on.. PT PTs s al also so re requ quir ired ed..
Rating Plug Removal Tool
List Price
$75.00
TRTOOL
Product Number
List Price
$200.00 PLVC VC1G 1G01 01 per set
GO-135S
Product Number TVPBP
Product Number
$3000.00
The handheld MicroVersaTrip portable battery pack provides an independent power source for Enhanced MicroVersaTrip Plus and MicroVersaTrip PM trip units as an alternative to the TVRMS2 test set. The power pack is used to power up the trip unit to set or adjust trip set points when the breaker is on the bench or otherwise not powered up. It connects to the trip unit through the rating plug test jack. It requires three (3) ( 3) standard 9 Vdc alkaline batteries bat teries (not included). Product number TVPBP List Price, $75.00, GO-245A. MicroVersaTrip Plus and PM Portable Power Pack
G0-104A
List Price
MicroVersaTrip Portable Power Pack
Description
POWER LEADER Power Supplies
GO-245B
The test kit product number TVRMS2 is a portable, battery-powered, test kit which provides for trip unit health checks and functional trip and no-trip tests. It also provides defeat of the ground-fault function and can be used in conjunction with high-current test equipment. The test kit can be used to provide +24V power to the trip unit for cold set-up and viewing of trip targets. This test kit is for use with RMS-9, Epic, MicroVersaTrip Plus and MicroVersaTrip MicroVersaTrip PM trip units. The kit uses six rechargeable ni-cad or standard alkaline "D" cells supplied by the customer. Kit can also be powered by 120 Vac source. Description
Neutral Current Sensor
List Price
$12.00
distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
5-20
BuyLog Catalog
www.geelectrical.com
Rev. 12/04
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break II Circuit Breakers Stationary and Draw-out Breaker Accessories All devices UL Listed Listed for factory or field installation except where noted.
S E R S E A K C A E D R E B T T A I L U U C S R I N I C
Accessories—Stationary and Draw-out Breakers The complete line of Power Break II breaker accessories may be either factory or field installed to meet user needs. The electronic shunt trip, the bell alarm, the bell alarm with mechanical lockout, and the undervoltage release modules are drop-in from the front of the breaker, interchangeable across all frames, and require no field internal wiring or breaker disassembly. Auxiliary switch modules are available in groups of 4, 8 or 12, NO/NC single- pole, double-throw (SPDT) switches. Their installation simply involves removal of breaker cover, installation of the switch module, routing of wiring and installation of the pre-wired terminal block and re-installation of the cover. Auxiliary switches are also interchangeable across all Power Break II breaker frames.
Electrical Operator
GO-245B
5
The electrical operator mounts inside the front cover of the manually operated breaker. This accessory can be added to any Power Break II breaker in the factory or the field to provide electrical spring charging and charge indication. For remote closing, the remote close sole- noid must be priced and ordered separately. All breakers are prewired to dedicated second- ary terminals for easy field installation. When electrical operation is used, either a shunt trip or an undervoltage release must be ordered and priced separately. Ratings Vac
Ratings Vdc
Field Installable Product Number
Factory Installed Product Number
List Price
List Price
120
–
SPE120R
$1671.00
SPE120
$1838.00
240
–
SPE240R
$1869.00
SPE240
$2056.00
–
24
SPE024R
$1869.00
SPE024
$2056.00
–
48
SPE048R
$1869.00
SPE048
$2056.00
–
72
SPE072R
$1869.00
SPE072
$2056.00
–
125
SPE125R
$1869.00
SPE125
$2056.00
Remote Close Solenoid
Electrical Operator
GO-245B
This accessory provides an electrically operated solenoid which, when energized, closes the breaker. It is suitable for control interlock schemes in which manual closing capability would not be convenient or desirable. The breaker is provided with a manual close button, which can be replaced by the Hidden "ON" Button accessory and/or sealed using the Limited Access Pushbutton Cover accessory. The remote close accessory is continuously rated and has an anti-pump feature, which prevents a motor operated breaker from repeatedly closing into a fault. Closing control voltage must be removed and re-applied for each breaker closure. Ratings Vac
Ratings Vdc
Field Installable Product Number
Factory Installed Product Number
List Price
List Price
120
–
SPRCS120R
$286.00
SPRCS120
$315.00
240
–
SPRCS240R
$286.00
SPRCS240
$315.00
–
24
SPRCS024R
$286.00
SPRCS024
$315.00
–
48
SPRCS048R
$286.00
SPRCS048
$315.00
–
72
SPRCS072R
$286.00
SPRCS072
$315.00
–
125
SPRCS125R
$286.00
SPRCS125
$315.00
Remote Close Solenoid
Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com Rev. 12/04
www.geelectrical.com
BuyLog Catalog
5-21
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break II Circuit Breakers S E R S E A K C A E D R E B T T A I L U U C S R I N I C
5
Stationary and Draw-out Breaker Accessories All devices UL Listed for factory or field installation except where noted.
Shunt Trip
GO-245B
The shunt trip accessory is an electronic module, which provides remote control capability to open the circuit breaker. When activated, the shunt trip module sends a signal to the trip unit to open the breaker. This allows the trip unit to record, display, distinguish and communicate (in MicroVersaTrip PM trip units) that the opening event was initiated by the shunt trip device. The shunt trip is continuously rated and requires no cut-off switch. When energized, the shunt trip supplies +24Vdc power to the trip unit to power the display. Ratings Vac
Ratings Vdc
Field Installable Product Number
Factory Installed Product Number
–
12
SPST012R
$301.00
SPST012
$328.00
24
24
SPST024R
$301.00
SPST024
$328.00
List Price
List Price
48
48
SPST048R
$301.00
SPST048
$328.00
120
125
SPST120R
$301.00
SPST120
$328.00
208
–
SPST208R
$301.00
SPST208
$328.00
240
250
SPST240R
$301.00
SPST240
$328.00
480
–
SPST480R1
$301.00
SPST4801
$328.00
60 0
–
SPST60 0R1
$301.00
SPST6001
$328.00
Shunt Trip Module
1Kit contains externally mounted transformer.
Shunt Trip with Lockout Module GO-245B The shunt trip with lockout is identical to the regular shunt trip, but when energized, it will also prevent closure of an "open" breaker by mechanically blocking both manual and electri- cal closing. When energized, the closing springs will not discharge, the movable contacts will not move; the contacts are "kiss free." Ratings Vac
Ratings Vdc
Field Installable Product Number
Factory Installed Product Number
List Price
List Price
12
SPSTL012R
$401.00
SPSTL012
$428.00
24
24
SPSTL024R
$401.00
SPSTL024
$428.00
48
48
SPSTL048R
$401.00
SPSTL048
$428.00
120
125
SPSTL120R
$401.00
SPSTL120
$428.00
208
–
SPSTL208R
$401.00
SPSTL208
$428.00
240
250
SPSTL240R
$401.00
SPSTL240
$428.00
480
–
SPSTL480R1
$401.00
SPSTL480
$428.00
60 0
–
SPSTL60 0R1
$401.00
SPSTL600
$428.00
1Kit contains externally mounted transformer.
distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
5-22
BuyLog Catalog
www.geelectrical.com
Rev. 12/04
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break II Circuit Breakers Stationary and Draw-out Breaker Accessories All devices UL Listed for factory or field installation except where where noted.
Undervoltage Release Module
S E R S E A K C A E D R E B T T A I L U U C S R I N I C
GO-245B
The undervoltage release is an electronic module used to open the circuit breaker when the monitored voltage drops below 35-60% of its rated value, and prevents the breaker from being closed until the monitored voltage exceeds 80% of its rated value. An undervoltage release trip operation is produced by the MicroVersaTrip Plus unit in response to a signal from the undervoltage release module. This allows the trip unit to record, display, distinguish and communicate (in MicroVersaTrip PM trip units) that the breaker opening event was due to undervoltage release. Operation of the undervoltage release module will prevent breaker contact closure, i.e. "kiss-free" operation. When ener- gized, the undervoltage release supplies +24 Vdc power to the trip unit to power the display. Ratings Vac
Ratings Vdc
Field Installable Product Number
24 48 120 208 240 480 60 0 – –
– – – – – – – 24 48
SPUVO24ACR SPUVO48ACR SPUV120ACR SPUV208ACR SPUV240ACR SPUV480ACR1 SPUV60 0ACR1 SPUVO24DCR SPUV048DCR
– –
125 250
SPUV125DCR SPUV250DCR
Factory Installed Product Number
List Price
$301.00
$301.00 $301.00
$301.00
$301.00 $301.00
$301.00
$301.00
$301.00
$301.00 $301.00
5
List Price
SPUV024AC SPUV048AC SPUV120AC SPUV208AC SPUV240AC SPUV480AC1 SPUV600AC1 SPUV024DC SPUV048DC
$328.00
$328.00
$328.00
$328.00
$328.00
SPUV125DC SPUV250DC
Undervoltage Release Module
$328.00
$328.00 $328.00
$328.00
$328.00 $328.00
1Kit contains externally mounted transformer.
Time Delay Module for UVR
GO-245B
The time delay module prevents nuisance tripping due to momentary loss of voltage. The module has 120 Vac input and 125 Vdc output and must be used with the 125 Vdc UVR. Description
Product Number
Time Delay Module (0.1 to 1.0 second delay)
SPUVTD
List Price
$430.00
Bell Alarm (Alarm Only)
GO-245B
The bell alarm module is used to signal breaker "tripped" status to other accessories (e.g., external alarm devices, indicating lights, relays, or logic circuits) for remote indication and interlocking functions. The bell alarm response is configurable by means of rear-mounted DIP switches on the trip unit. The bell alarm can be made to operate in response to an over- current (including ground fault) or protective relay trip and/or a shunt trip operation, and/or operation of the undervoltage release module. It is not actuated as a result of normal breaker "ON/OFF" operation. This module provides a visual, mechanical pop-out target, which protrudes through the face of the circuit breaker door when it operates. The bell alarm may be reset manually by depressing the mechanical target, or automatically by closing the breaker. The bell alarm is provided with one SPDT switch with control power duty contacts as shown in the auxiliary switch accessories. Ratings Vac
Ratings Vdc
Field Installable Product Number
240 60 0
125-250 125-250
SPBAA240R SPBAA600R1
Factory Installed Product Number
List Price
$124.00 $124.00
SPBAA240 SPBAA600
Bell (Alarm Only)
List Price
$135.00
$135.00
1600 Vac module not UL Listed.
Reference: See Section 21 Publications and Reference: See for a list of additional product-related publications distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com Rev. 12/04
www.geelectrical.com
BuyLog Catalog
5-23
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break II Circuit Breakers S E R S E A K C A E D R E B T T A I L U U C S R I N I C
5
Stationary and Draw-out Breaker Accessories All devices UL Listed for factory or field installation except where noted.
Bell Alarm With Lockout
GO-245B
The bell alarm with lockout module combines both the bell alarm and a manual lockout func- tion. The bell alarm switch operates identically to the standard bell alarm module, except that the mechanical pop-out target must be manually reset before the breaker can be closed. Operation of the bell alarm with lockout module can be independently set by means of set- ting the DIP switches at the rear of the trip unit. Current rating of the single SPDT switch is identical to the auxiliary switch accessories. Ratings Vac 240 60 0
Ratings Vdc 125-250 125-250
Field Installable Product Number
SPBAL240R SPBAL600R1
Factory Installed Product Number
List Price $124.00 $124.00
SPBAL240 SPBAL600
List Price
$135.00
$135.00
1600 Vac module not UL Listed.
Bell Alarm with Mechanical Reset Lockout
Auxiliary Switch An auxiliary switch signals the circuit breaker’s primary contact position (i.e., OPEN or CLOSED) to other devices, such as indicating lights, relays or logic circuits. This enables the user to provide remote indication, interlocking or control operations as a function of breaker primary contact position. The auxiliary switch operation is independent of the method by which the breaker is opened or closed. The auxiliary switch does not distinguish between a "tripped" or "open" condition. The auxiliary switch contacts follow the main breaker contacts on opening and precede them on closing. Auxiliary switch modules are available with 4, 8 or 12 NO/NC (SPDT) switches for control power duty ac/dc ratings. When ordered for field installation, an auxiliary switch module comes pre-wired to its own terminal board, which mounts with one screw to the left of the breaker. A special accessory, available for draw out breakers, comes pre-wired to the breaker secondary disconnect. All switch ratings are 6A at 120V-600 Vac, 1/2A at 125 Vdc and 1/4A at 250 Vdc. Auxiliary Switch with Pre-wired Secondary Term Terminals inals for Stationary Breaker
Auxiliary Switches for Stationary Breakers Ratings Vac
Ratings Vdc
No. of SPDT SPDT Switch Elements (Contacts)
240 240 240 60 0 60 0
125-250 125-250 125-250 125-250 125-250
4 8 12 4 8
Field Installable Product Number SPAS240AB4R SPAS240AB8R SPAS240AB12R SPAS60 0AB4R1 SPAS60 0AB8R1
GO-245B Factory Installed Product Number
List Price
$268.00
$564.00
$651.00 $268.00 $564.00
List Price
SPAS240AB4 SPAS240AB8 SPAS240AB12 SPAS600AB41 SPAS600AB81
$293.00
$616.00
$710.00 $293.00 $616.00
1600 Vac module not UL Listed.
Auxiliary Switches for Draw-out Breakers Ratings Vac
Ratings Vdc
No. of SPDT SPDT Switch Elements (Contacts)
240 240 240 60 0 60 0
125-250 125-250 125-250 125-250 125-250
4 8 12 4 8
1600 Vac module not UL Listed.
GO-245B
Field Installable Product Number SPAS240AB4DR SPAS240AB8DR SPAS240AB12DR SPAS60 0AB4DR1 SPAS60 0AB8DR1
Factory Installed Product Number
List Price
$551.00 $847.00
$934.00 $551.00 $847.00
SPAS240AB4D SPAS240AB8D SPAS240AB12D SPAS600AB4D1 SPAS600AB8D1
List Price $576.00 $899.00 $993.00 $576.00 $899.00
Auxiliary Switch with Pre-wired Secondary Term Terminals inals for Draw-out Draw-out Breaker
distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
5 24
BuyLog Catalog
www.geelectrical.com
Rev. 12/04
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break II Circuit Breakers Stationary and Draw-out Breaker Accessories All devices UL Listed for factory or field installation installation except where noted.
Mechanical Operations Counter
S E R S E A K C A E D R E B T T A I L U U C S R I N I C
GO-245B
The mechanical operations counter is mounted behind the front cover of the breaker. It is viewable through a rectangular knockout window opening in the breaker cover. It is a five-digit, non-resettable counter, which is actuated each time the breaker is opened by any mean means. s. Field Installed Product Number
SPCOUNTERR
$100.00
5
Factory Installed Product Number
List Price
List Price
SPCOUNTER
$125.00
Mechanical Operations Counter
Limited Access Pushbutton Cover
GO-245B
This accessory limits access to "ON/OFF" control of a breaker to authorized personnel. The pushbutton cover accessory consists of transparent hinged covers that can be individually sealed to the limited access assembly. Both the "ON" and "OFF" buttons can be pilot drilled to allow use of a 1/8" rod to operate either one or both pushbuttons. Field Installed Product Number
Factory Installed Product Number
List Price
SPPBCOVERR
$80.00
List Price
SPPBCOVER
$90.00
Breaker with limited access pushbutton cover assembly installed
Hidden "ON" Button
GO-245B
The hidden "ON" button is assembled to the mechanism behind an unlabeled, false pushbutton. Manual closing of the breaker can only be performed by means of a small diameter personnel.rod. This accessory is used to limit access to the manual "ON" control to authorized Field Installed Product Number SPPBNONR
Factory Installed Product Number
List Price
$64.00
List Price
SPPBNON
$64.00
Activating the breaker closing mechanism through the hole in the Hidden “ON” Button
Replacement Trip Unit Access Doors
GO-148G
Description
Product Number
Micr Mi croV oVer ersa saT Tri rip p Pl Plus us an and d PMTri rip p Un Unit its s Power Plus Trip Units
100 0054 5433 335P 5P1 1 10 054335P2
List Price
$20.00
$16.00
Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
www.geelectrical.com
Rev. 12/04
BuyLog Catalog
5 25 Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break II Circuit Breakers S E R S E A K C A E D R E B T T A I L U U C S R I N I C
5
Stationary and Draw-out Breaker Accessories All devices UL Listed for factory or field installation installation except where where noted.
Key Interlock Provisions The key interlock provision enables the user to mount a one- to four-cylinder, narrow-faced, Kirk-type FN or Superior customer-supplied lock on the face of the breaker. This accessory provides mounting for key interlocks that are furnished by the customer. The key interlock provision works in conjunction with the padlock provision. The key interlock extends a lever through the padlock hasp when the key is turned to the key removal or bolt extended posi- tion. Additionally, the accessory provides a hasp for mounting three padlocks with 1/4" to 3/8" diameter shanks.
Key Interlock Reference Table Product Number
Number of Locks
Kirk Key Lock Product Number
SPK4 SPK4 SPK4 SPK4
1 2 3 4
KFN00 0011 KFN000 021 KFN000 031 KFN000 041
Superior Product Number S105827Y S105828Y S105829Y S105827-4Y
Key Interlock Kit (lock not included)
1Final digit may be 0, 1, 2 or 3 depending on number of key removal positions.
Product Numbers, Key Interlock Provisions
GO-245B
Circuit Breaker Envelope Size (Amps)
Number of Key Locks
Field Installed Product Number
All
1 to 4
SPK4R
Factory Installed Product Number
List Price
$355.00
SPK4
Door Interlock
List Price $426.00
GO-245B
The door interlock provides interlocking of the circuit breaker compartment’s hinged door so that the breaker must be in the "OFF" position before the door can be opened. The door inter- lock is defeatable with a small tool to allow authorized access. Field Installed Product Number SPDILR
Factory Installed Product Number
List Price
$173.00
List Price
SPDIL
$208.00
Padlock Provisions (Standard) Padlocking provisions are standard on all Power Break II circuit breakers. When the breaker is in the open position, and the padlock hasp is raised at least 1/4", the breaker cannot be closed mechanically or electrically. The hasp accepts up to three padlocks with 1/4" to 3/8" diameter shanks.
Walking Beam Interlocks—Stationary Breakers Only
Door Interlock
GO-245B
Walking beam interlocks are mechanical devices used to prevent two adjacent circuit break- ers from both being in the "ON" or closed position at the same time. However, both breakers can be in the "OFF" or open position. Circuit Breaker Envelope Size (Amperes)
Product Number
800, 160 0 and 20 00 300 0 400 0
SPWB20 SPWB30 SPWB40
List Price
$1228.00
$1228.00
$1228.00
distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
5 26
BuyLog Catalog
www.geelectrical.com
Rev. 12/04
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break II Circuit Breakers Stationary Breaker Mounting Kits All devices UL Listed Listed for factory or field installation except where noted.
Lug Adapter Kits
GO-245B
S E R S E A K C A E D R E B T T A I L U U C S R I N I C
Kits pre-mount to bus structure allowing cabling or bussing to be completed prior to breaker mounting. Accepts either lugs or crimp-type connector terminals. Kit includes adapter and hardware for either a three-pole line-side, or a three-pole load-side connection. (Lugs not included). Frame Rating (Amperes)
Product Number
800
TPLUGA08
1600
TPLUGA162
2000
SPLUGA203
5
Suitable for use with up to: 3 TPLUG108 Lugs or 3 crimp Lugs1 per pole 6 TPLUG108 lugs or 6 crimp Lugs1 per pole 6 TPLUG108 Lugs or 6 crimp Lugs1 per pole
List Price
2000 Ampere Power Break II breaker with SPLUGA20 lug adapter kit and 18 lugs (TPLUG108)
$78.50
$389.00
$487.00
1Anderson No. VCEL-075-12H1 or equivalent 2 T-Studs - TP16FCA - included with adapter 3 T-Studs - SP20FCA - included with adapter
Type TPLUG206
Lug Kits
GO-245B
Kits accept Cu/AI wire and are suitable for direct mounting to the breaker. When ordering Type TPLUG kits, order one kit per line or load pole. Example: A complete set of lugs for the line side of an 800A frame, 400A trip breaker would be Qty 3-TPLUG106 lugs. When ordering TSLUG kits order one kit per line or load side; TSLUG kits require use of T-studs. Example: A complete set of lugs for a 3000A frame, 2500A trip breaker would be Qty 1-TSLUG25. T-Studs would also be required. Circuit Breaker Max Rating Envelope Size (Amperes) (Amperes)
800
1600
2000
300 0 400 0
Product Number
Lug Per Kit
Max. Ca Cables Per Pole
400 600 800 800 800 1600
TPLUG106 TPLUG206 TPLUG308 TPLUG1084 TPLUG1084 TPLUG408
1 1 1 1 1 1
1 2 3 3 6 4
2000 800 1200 1600 2000 2500 3000 4000
TPLUG1084 TSLUG08 TSLUG12 TSLUG16 TSLUG20 TSLUG25 TSLUG30 TSLUG40
1 9 12 15 18 21 27 27
6 3 4 5 6 7 9 9
Wire Range kcmil Cu/AI
List Price
(2) #2 2-600 (2) #2 2-600 (3) 300-750 3/0-80 0 3/0-80 0 500-80 0 3/0-80 0 3/0-80 0 3/0-80 0 3/0-80 0 3/0-80 0 3/0-80 0 3/0-80 0 3/0-80 0
4 For use with adapter kit only. See table above.
$18.50 $27.50 $32.00 $23.00 $23.00 $39.00 $23.00 $274.00 $296.00
$345.00
$383.00
$418.00
Type TPLUG408
$630.00 $1045.00
Type TPLUG308
Type TSLUG20
Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
www.geelectrical.com
Rev. 12/04
BuyLog Catalog
5-27 Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break II Circuit Breakers S E R S E A K C A E D R E B T T A I L U U C S I R N I C
5
Stationary Breaker Mounting Kits, Wall Mounted Enclosures, Floor Mounted Enclosures All devices UL Listed for factory or field installation except where noted. T-Studs T-studs mount directly to the breaker, and can be rotated for either vertical or horizontal bus connection. 4000 ampere T-studs are for vertical bus bars only. Product number includes one stud. Both copper and aluminum T-studs are tin-plated.
T-Studs—Front Connected Breaker Circuit Breaker Frame Size (Amperes)
GO-245B
Max. Ra Rating (Amperes)
800 800 2000 2000 2500 2500 3000 4000 4000
800 800 800-2000 800-2000 2000 2500 3000 4000 4000
Product Number
List Price
SP08FCA1
$36.00
SP08FCC2 SP20FCA1 SP20FCC2 SPS20FCA1 SPS25FCC2 SPS30FCC2 SPS40FCC2 SPS40LFCC2,3
$36.00 $49.00 $49.00 $48.75 $51.50 $181.50 $395.00
T-Studs—Back Connected Breaker Circuit Breaker Frame Size (Amperes)
GO-245B
Max. Ra Rating (Amperes)
2500 2500 3000
2000A Breaker with "T" Studs Mounted
$240.50
Product Number
List Price
SPS20BCA1,4 SPS25BCC2,4
2000 2500 3000
$48.75 $51.50
2,5
$181.50
1Aluminum 2 Copper 3 Extra long stud. Alternate with SPS40FCC for ease of installation. 4 Six T-studs at no charge when ordered with breaker 5 Supplied with integral T-stud
Stationary Breakers General Purpose, Wall Mounted Enclosures General purpose, NEMA 1 enclosures are available for Power Break II breakers with neutrals for 800, 1600 and 2000 amperes. These units are UL Listed for service entrance use for single-phase three-wire, three-phase three-wire, or three-phase four-wire power systems through 600 Vac. Enclosures are provided with breaker mounting studs and lugs. Enclosures, breakers and neutrals are ordered and shipped separately, unassembled. These units are suitable for use in 65 kA (max.) rms symmetrical symmetrical systems. Floor mounted enclosures are available. For Ordering and Pricing, see Engineered Products Catalog, Section 3: Individually Mounted Circuit Breakers.
Wall Enclosure and Field Installed Neutral Circuit Breaker Envelope Size (Amperes)
Current Sensor Rating (Amperes)
Enclosure 7 Product Number (include Lugs)
800 1600 2000
20 0-800 100 0-1600 20 00
SPB08W SPB16W SPB20W
Field installed Neutral Product Number
List Price GO-134C
$2569.00
$3667.00
$4309.00
TNT800 TNT1600 TNT2000
List Price GO-149
$384.00
$437.00
$537.00
7 For single-phase, 3-wire or 3-phase, 4-wire systems with internal ground fault protection, appropriate neutral CT must
be ordered with circuit breaker from page 5-20.
Trimplate
GO-245B
Factory Installed Product Number
Field Installable Product Number
SPTRIMPLATE
SPTRIMPLATER
List Price
$64.00
distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
5-28
BuyLog Catalog
www.geelectrical.com
Rev. 12/04
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break II Circuit Breakers Draw-out Breakers and Accessories
S E R S E A K C A E D R E B T T A I L U U C S R I N I C
Features —Draw-outs through 4000 ampere —Draw-outs amperess are UL Listed, 100% rated —Modular design for simplified installation—6 basic sizes—800, 1600, 2000, 2500, 3000, 4000 —5 inch pole centers centers —Screw racking mechanism provides positive racking motion —Self aligning primary and secondary disconnects —Four position draw-out—engaged, test, disengaged, fully withdrawn— simplifies system testing and inspection —Breaker position indicator clearly shows breaker position —Provisions for padlocking breaker in test or disengaged position —Mechanical interlock logic prevents movement of a closed breaker —Suitable for reverse feeding
5
Draw-out Breaker in Substructure
Description The draw-out assembly consists of a substructure housing unit designed as a compact self- supporting unit and a draw-out breaker which must be ordered separately. The substructure contains mounting holes, self-supporting male plugs and extendable rails, and can be ordered separately for installation in your switchboard or enclosure. The Power Break II draw-out breaker is a self-contained, heavy-duty assembly designed to offer simplified breaker inspection without de-energizing the main bus structure. The draw-out breaker comes complete with racking mechanism drive, wheels, primary and secondary disconnects and cooperating interlock systems. Accessories such as dead-front shutters, by-pass switches (position switches), and padlock devices are available and field installable.
OEM Substructures
GO-245B
Substructures are available Substructures available for both both standard and Hi-Break Hi-Break Power Break Break II breakers. breakers. Holes are provided for bolting on a shelf or supports. Holes are also provided in the primary stabs for bolting to busbars or terminal lugs. Substructure secondary disconnects are ordered and priced separately. Order Hi-Break substructures for use with Power Break II switches. Frame Rating (Amperes)
Standard Break Product Number
Hi-Break Product Number
List Price
List Price
80 0
SPSDOS08
$671.00
SPHDOS08
160 0
SPSDO S16
$1300.00
SPHDOS16
$1403.00
20 0 0
SPSDOS20
$1892.00 $2048.00
SPHDOS20
SPSDOS25
250 0
SPHDOS25
$2040.00 $2207.00
30 0 0
SPSDOS30
$2739.00
SPHDOS30
$2951.00
40 0 0
SPSDOS40
$6916.00
SPHDOS40
$7455.00
Secondary Disconnect for Draw-out Breakers
$724.00
GO-245B
Control wiring is connected through draw-out secondary disconnects in the "TEST" and "CONNECTED" positions only. Up to 72 control circuits are possible through 36 position plug-style secondary disconnect blocks factory mounted to each side of draw-out breakers. One substructure disconnect (SPDOSD36S) must be ordered for each breaker when acces- sories or communications are used. When auxiliary switches are used along with any other electrical accessory or communications, two disconnects must be ordered. Location
Product Number
List Price
Substructure
SPDO SD36S
$283.00
Breaker1
SPDOSD36B
$283.00
1Order for replacement only. Included and factory wired with draw-out breaker.
Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
1600-ampere substructure for standard break breaker
Rev. 12/04
www.geelectrical.com
BuyLog Catalog
5-29 Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break II Circuit Breakers S E R S E A K C A E D R E B T T A I L U U C S R I N I C
5
Draw-out Breakers and Accessories All devices UL Listed for factory or field installation except where noted.
Shutter Kit
GO-245B
This field installable kit provides shutters used to prevent uninten- tional contact with potentially live primary disconnect stabs when a breaker is racked out of an energized switchboard compartment. Frame Rating
Product Number
80 0-20 0 0A
SPDSS20
List Price $501.00
30 0 0A
SPDSS30
$501.00
40 0 0A
SPDSS40
$501.00
By-Pass Switch
Racking Tool
GO-245B
The racking tool is a drive wrench with a square 1/2" socket that engages the racking mechanism of the draw-out breaker. One rack- ing tool is supplied with every five draw-out breakers at no charge. Frame Rating
Product Number
All
TDO RT
List Price
$70.00
GO-245B Mechanical Interlocks
Provides positive indication that the draw-out breaker or switch primary contact fingers are fully connected to the main bus in the substructure. Switch contacts change states only after the primary fingers are fully connected when the breaker is being moved from the DISCONNECTED position through the TEST position and into the CONNECTED position. May be used to provide control circuit continuity or downstream signaling that the draw-out breaker is connected in addition to the visual position indicator on the draw-out substructure. The By-pass switch accessory does not indicate either the TEST or DISCON- NECTED position. The switch assembly mounts on the stationary frame and the actuator mounts to the carriage. Switch contacts are rated at 10A at 600 Vac, 0.75A at 125 Vdc, and 0.25A at 250 Vdc. Number of Switch Elements
Product Number
2 NO /2 N C
TDO BP2L
$177.00
4 NO /4 N C
TDO BP4L
$256.00
6 NO /6 N C
TDO BP6L
$336.00
List Price
Racking Padlock Provision
GO-245B
The racking padlock provides a means for the user to prevent racking tool engagement, thereby preventing movement of the breaker between the DISCONNECTED, TEST and CONNECTED positions. Frame Rating
Product Number
All
TDOPC
List Price
$46.00
GO-245B
Mechanical interlocks provide the same function as the walking beam accessory for stationary breakers, except they are used with two draw-out breakers: mounted on common compartment center- line, in either the same vertical section or adjacent vertical sections. Envelope Size
Product Number
80 0-20 0 0
SPDOWB20
List Price $1310.00
250 0-40 0 0
SPDOWB40
$1310.00
Rail Kit
GO-245B
This field installable rail kit may be used to shorten the two standard OEM substructure rails by 3-1/2 inches. Product Number SPRAILS
List Price
$310.00
Position Switch
GO-245B
Provides positive indication when the draw-out breaker or switch primary contact fingers have been fully withdrawn from the main bus connections. Switch contacts change state only after the primary fingers are fully disconnected when the breaker is being moved from the CONNECTED position through the TEST position and into the DISCONNECTED position.
May be used as part of a safety interlocking system in addition to the visual indicator on the draw-out substructure. The Position Lifting Bar GO-245B Switch accessory does not indicate either the TEST or CONNECTED The lifting bar provides a means of safely lifting a draw-out circuit position. The switch assembly mounts on the stationary frame and breaker. A chain hook can be attached to the central hole in the lift- the actuator mounts to the carriage. Switch contacts are rated at ing bar or a 1" diameter black iron pipe can be put through the two 10A at 600 Vac, 0.75A at 125 Vdc, and 0.25A at 250 Vdc. holes above the hooks, allowing two people to carry the breaker Number of below waist level from either side of the breaker. Switch Elements Product Number List Price
One lifting bar is supplied with every five draw-out breakers at no cha charge. rge. Frame Rating
Product Number
All
TDOLB
2 N O/2 N C
SDO PS2L
$177.00
4 N O/4 N C
SDO PS4L
$256.00
6 N O/6 N C
SDO PS6L
$336.00
List Price
$104.00
distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
5-30
BuyLog Catalog
www.geelectrical.com
Rev. 12/04
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break I Circuit Breakers Ratings and Trip Characteristics
S E R S E A K C A E D R E B T T A I L U U C S R I N I C
Power Break I Circuit Breakers for DC Applications and Replacement AC Needs The GE line of Power Break I insulated case circuit breakers offers the rugged, reliable sys- tem protection critical for heavy-duty DC power applications and for the replacement, add- on and hole-filler needs of existing AC applications. Power Break circuit breakers are rated up to 200,000 amperes rms symmetrical interrupting capacity without fuses or current lim- iters. The Power Break design consists of five physical envelope sizes, providing protection from 100 to 4000 amperes. Power Break I is a versatile breaker, breaker, designed for a wide variety of applicatio applications ns with features including temperature temperature insensitive trip units, push-to-open and close buttons, maximum five- cycle close time, UL Listed, field-installable rating plugs to change a breaker’s rating, UL Listed, (file E11592), field-installable field-installable accessories, easy to operate, rotary, rotary, charge storage handle.
5
800A Envelope
A full line of selective tripping characteristics can be used to provide overcurrent protection from overloads, short circuits and ground faults. Additionally, local trip indicators (targets) visually signal long-time, short-time, instantaneous and ground fault trips. Power Break I circuit breakers with enhanced MicroVersaTrip solid state trip units and MagneTrip dual-magnetic trip units offer application flexibility for ac as well as dc systems. Power Break with MagneTrip is rated up to 700 Vdc and 750 Vac. MagneTrip is 100 percent rated for ac or dc power distribution systems. MagneTrip also offers interchangeable trips for 3000 ampere envelope size. A full line of Power Break draw-out substructures, interlocks, accessories, internal electrical operators, connectors, a portable digital test kit, and a portable battery power pack is available. MicroVersaTrip trip units for Power Break insulated case circuit breakers digitally measure the true RMS (heating) value of the current, regardless of the wave shape, by RMS digital sensing of sinusoidal and non-sinusoidal currents.
2000A Envelope
Features —High-dielectric strength, glass reinforced insulating case for increased durability and safety of operation. —Interphase barrier partitions mesh with breaker cover to completely isolate each pole for high transient voltage withstandability. —Green (OFF), Red (ON), indicators display the position of the breaker contacts. —Extra heavy-duty, low torque-handle mechanism for simple, stored energy charging. —Easy quick-make, quick-break UL-Listed close/open —Complete line of accessories, foroperation. field installation. —Short circuit ratings through 200,000 Amperes. —RMS digital sensing of sinusoidal and non-sinusoidal currents by the solid-state trip device. —Field-installable, interchangeable rating plus. —Two trip unit options: —MicroVersaTrip Plus trip units for overcurrent protection. —MicroVersaTrip PM trip units for metering, protective relays, and GE POWER LEADER communications.
3000A Envelope
4000A Envelope
Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04
www.geelectrical.com
BuyLog Catalog
5-31 Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break I Circuit Breakers S E R S E A K C A E D R E B T T A I L U U C S R I N I C
5
Draw-Out Breakers
Features —Draw-Outs through 4000 amperes are UL Listed, 100% rated —Modular design for simplified installation—6 basic sizes—800, 1600, 2000, 2500, 3000 and 4000 amperes—5-inch pole centers —Screw racking mechanism provides positive racking motion —Self aligning primary and secondary disconnects —Four position draw-out—engaged, test, disengaged, fully withdrawn—simplifies system testing and inspection —Breaker position indicator clearly shows breaker position —Provisions for padlocking breaker in test or disengaged position —Mechanical interlock logic prevents movement of a closed breaker —Suitable for reverse feeding TC3030TT
Description The draw-out assembly consists of a substructure housing unit designed as a compact self supporting unit and a draw-out breaker which must be ordered separately. The substructure contains mounting holes, self supporting and secondary nect strips, extendable rails, andmale can plugs be ordered separatelydiscon- for installation in your switchboard or enclosure. The Power Break draw-out breaker is a self-contained, heavy duty assembly designed to offer simplified breaker inspection without de-energizing the main bus structure. The draw-out breaker comes complete with racking mechanism drive, wheels, primary and secondary disconnects and cooperating interlock systems. Accessories such as dead-front shutters, position switches, and padlock devices are available and field installable.
NOTE: These draw-out breakers are not suitable for use in old style (TPD, THD) substructures. Breaker rotated for inspection
distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
5-32
BuyLog Catalog
www.geelectrical.com
Rev. 12/04
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break I Circuit Breakers How To Order How To Order
Pricing Example
GO-145C
Power Break frames are factory configured either for MicroVersaTrip Plus trip units only (frame suffix “T” or “TT”) or for MicroVersaTrip PM trip units, (frame suffix “TR” or “TTR”). If provi- sion for 24 Vdc trip unit control power for MicroVersaTrip Plus trip units is required, or if provision for future upgrade to MicroVersaTrip PM, is desired, select frames with “TR” or “TTR” suffixes from page 5-40. For draw-out frames select the appropriate substructure mounted trip unit secondary disconnect from page 5-51.
1600 ampere frame, 100kA, 480 Vac IC rating, 1000 ampere sensor, 600 ampere frame, 100kA, 480 Vac IC rating, 1000 ampere sensor, 600 ampere rating plug, 100% rated draw-out construction, 120 Vac shunt trip assembled, trip unit functions to include long-time (L), short-time (S), high range instantaneous (H), 120 Vac electrical (motor) opera- tion (E1), trip targets, draw-out substructure. Description
Product Number
Fram Fr ame e and and Su Suff ffix ix ($ ($86 8671 71 + $16 $1656 56))
THC1 TH C161 610T 0TTH THE1 E1
$27890.00
1. Determine the required breaker frame, IC/short-time rating, and load requirements. Select appropriate stationary or draw-out breaker frame product number and list price on page 5-40.
Trip Unit and Suffix Adder
C210LSH
$2700.00
Rating Plug
TR10B600
$178.00
Shunt Trip (Assembled)
TPST12S
No Charge 1
2. Select and price the appropriate frame modification from page 5-42.
Draw-out Substructure
THDOS16E
$3230.00 1
Secondary Disconnects (2)
TDOSD6S
3. Select the basic MicroVersaTrip trip unit to match the frame ampere rating from page 5-43. 4. Select and price the trip unit suffix from page 5-43 and 5-44 to match the required trip functions. Refer to page 5-37 for trip unit characteristics.
$320.00 1
1GO-145A.
Power Break I Rating Plug (X) and Current Sensor (S) Rating Frame Max. Sensor Rating Envelope Size Rating (Amperes) ( Amp Amper eres es)) ( S) S)
5. Select and price the required rating plug from page 5-45. The sen- sor rating of the frame must match the sensor rating of the plug.
800
6. Select and price lugs and accessories from pages 5-51 through 5-52. Draw-out substructure should be priced from page 5-39 if required. 7. When ordering, specify separate product numbers as follows. The trip unit will be installed in the frame. Rating plugs will be shipped separately. Specify “Assembled” for installed accessories. —Frame including modifications suffix —Trip unit including function suffix —Rating plug —Lugs (if required) —Accessories (if required)
List Price
800
Rati Ra ting ng Pl Plug ug A mpe mpere res s ( X) X)
200
100, 150, 200
400
150, 200, 225, 250, 300, 400
800
300, 400, 500, 600, 700, 800
1600
1600
1000 1600
400, 600, 800, 1000 600, 800, 1000, 1200, 1600
2000
2000
2000
800, 1000, 1200, 1600, 2000
2500
3000
4000
1000
400, 600, 800, 1000
2000
800, 1000, 1200, 1600, 2000
2500
1600, 2000, 2500
3000
3000
2000, 2500, 3000
4000
4000
1600, 2000, 2500, 3000, 4000
S = Sensor ampere rating X = Rating Plug amperes
Product Number Construction
TH P
MM
16
10
TT
E 1C
R Configured for
Circuit Breaker Current Interrupting Capacity
MicroVersaTrip PM trip unit
TP = Standard Break THP = Hi-Break ® TUP = Special Hi-Break 2 TC = Standard Break Draw-out THC = Hi-Break Draw-out
Auxiliary Breaker Frame Functions FC = Front Connected 1 E1-7 = Electrical Operation C = Concealed "ON" Button H = High Range Instantaneous Z = Zone Selective Interlocking
MagneTrip™ 2
Breaker Frame Rating 8 = 800 16 = 1600 20 = 2000
25 = 2500 30 = 3000 40 = 4000
Trip Type and Rati Rating ng TT = MicroVersaTrip™ Plus or PM Programmer
Sensor Current Rating (Amperes) Related to breaker sensor rating (MicroVersaTrip) or continuous current rating (MagneTrip Trip Unit).
2 = 200A 4 = 400A 8 = 800A 10 = 1000A
16 = 1600A 20 = 2000A 25 = 2500A 30 = 3000A 40 = 4000A
Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
1Stationary breakers only. 2 MagneTrip only.
Note: This information is provided for use interpreting product number. It cannot be used to build product numbers.
S E R S E A K C A E D R E B T T A I L U U C S I R N I C
5
www.geelectrical.com
Rev. 12/04
BuyLog Catalog
5-33 Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break I Circuit Breakers S E R S E A K C A E D R E B T T A I L U U C S R I N I C
5
Ratings and Trip Characteristics
The interruption ratings and voltages shown in the table are maximum ratings. A circuit breaker of the type given in the left-hand column may be applied at the given circuit voltage in any electrical distribution system where the available fault current at the load terminals of the breaker does not exceed the value in the table. That circuit breaker type may also be applied at intermediate valuesdoes of circuit voltage provided current at the load terminals of the breaker not exceed the value inthe theavailable table for fault the higher value of voltage.
Interrupting Capacity Envelope Size Type of Construction Max. Short time Rating, kA1 240Vac 480Vac Standard Break 60 0Vac 250Vdc2,3 240Vac 480Vac 60 0Vac 60 Hi-Break 250Vdc2,3 500Vdc2 600Vdc2 750Vac Special Hi-Break4 700Vdc
800 A
16 00 A
2000A
3000A
4000A
25 65 65 42 – 10 0 10 0 65 – – – – –
30 85 65 50 22 125 100 65 35 – – – –
30 85 65 50 – 125 10 0 65 – – – – –
42 100 100 85 42 20 0 150 100 85 65 65 35 65
42 10 0 10 0 85 42 20 0 150 10 0 85 65 65 35 65
1With "H" option MicroVersaTrip trip unit only. 600 Vac, 50/60 Hertz, 500 ms. Not available on 4000A
stationary breaker. 2 DC ratings apply only to Power Break breaker with MagneTrip trip unit. 3 1600 A frame MagneTrip (TPMM, THPMM, TCMM, and THCM) also rated 30kA, 500 Vdc, with poles in
series for ungrounded battery applications. 4 Ratings apply only to Power Break breaker with MagneTrip trip unit Type TUPMM. Not UL Listed.
Power Break Molded Case Switch Withstand Ratings
Switch Frame Size (Amperes)
Continuous Current Rating (Amperes)
Short-Time Rating, rms Rating, Sym Amperes at 600 Vac Max., 500 ms Max.
80 0 160 0 200 0 250 0 250 0 300 0 400 0
80 0 160 0 20 0 0 20 0 0 250 0 30 0 0 40 0 0
25,000 30,000 30,000 42,000 42,000 42,000 42,000
Suitable on 200,000 ms Sym Ampere Fault Circuit when protected by Class L Fuses as Follows: Line Size Max. Fu Fuse Ampere Rating
Load Side Max. Fu Fuse Ampere Rating
20 0 0 2500 2500 2500 2500 40 005 40 005
80 0 1600 20 00 2500 2500 30005 40005
Short Circuit Withstand Rating when Protected by Power Break Breaker with MicroVersaTrip Plus or MicroversaTrip PM Trip Unit Breaker Frame Size (Amperes) 80 0 20 0 0 20 0 0 40 0 0 40 0 0 40 0 0 40 0 0
480 Vac
600 Vac
10 0,000 10 0,000 10 0,000 10 0,000 10 0,000 10 0,000 10 0,000
65,000 65,000 65,000 65,000 65,000 65,000 65,000
5 Use only Hi-Break breaker with 4000 ampere fuses.
Dimensions and Weights Complete dimensions and weight information can be found in the Power Break I Application Guide, GET-6211.
distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
5-34
BuyLog Catalog
www.geelectrical.com
Rev. 12/04
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break I Circuit Breakers Ratings and Trip Characteristics
MagneTrip MagneTri p Trip Unit Characteristics Curre Cur rent nt Rati Ra ting ngs s (Amp (A mper eres es))
Ampere Ampe re Se Sett ttin ing g (Mul (M ulti tipl ple e of currre cu rent nt ra rati ting ng))
Long Time Tim e Dela De lay y (Sec (S ec.) .) 1
20 0, 400, 600 800, 100 0
0.7-1.0 0.7-1.0
4 4
3-10 3-10
0.04 0.04
3-10 3-10
None None
1200
0.7-1.0
4
3-8.2
0.04
3-8.2
None
1600
0.7-1.0
4
3-7.5
0.04
3-7.5
None
60 0, 800, 10 00
0.7-1.0
4
3-10
0.07
3-10
42,00 0
1200
0.7-1.0
4
3-8.2
0.07
3-8.2
42,00 0
1600
0.7-1.0
4
3-7.5
0.07
3-7.5
42,00 0
20 00
0.7-1.0
4
3-6.8
0.07
3-6.8
42,00 0
2500
0.7-1.0
4
2.3-5.5
0.07
2.3-5.5
42,00 0
30 0 0
30 00
0.7-1.0
4
3-5.3
0.07
3-5.3
42,00 0
40 0 0
40 00
0.7-1.0
4
2.2-4
0.07
2.2-4
42,00 0
Fra rame me Size Si ze
1600
2500
Short Time Shor Sh ortt-ti time me Pick Pi ckup up (M (Mul ulti tipl ple e of curr current ent ratin rating) g)
Adjustable Fixed Instan Inst anta tane neou ous s In Inst stan anta tane neou ous s Dela De lay y Pick Pi ckup up (M (Mul ulti tipl ple e Over Ov erri ride de (Sec.) (Sec. ) 2 of curre current nt rating) rating) (Ampe (Amperes) res)
1Time delay shown at 600 percent of breaker current rating at lower limit to trip time curve. 2 Time delay shown at 10X breaker current rating at lower limit of time curve.
Complete dimension and weight information can be found in the Power Break I application guide, GET-6211.
Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
S E R S E A K C A E D R E B T T A I L U U C S R I N I C
5
Rev. 12/04
www.geelectrical.com
BuyLog Catalog
5-35 Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break I Circuit Breakers S E R S E A K C A E D R E B T T A I L U U C S R I N I C
5
Trip Unit Features
Two Choices Of Advanced, Digital Solid-State Trip Units Enhanced MicroVersaTrip Plus and MicroVersaTrip PM trip units give you two ways to monitor and control the Power Power Break I breaker with unprecedented ease. Through the simple keypad, the trip unit lets you program and display a variety of functions including tripping characteristics, remote communications, status information and protective relaying, and allows integration with GE POWER LEADER Power Management Systems. The trip unit display also allows viewing of many standard metering parameters as well as pickup alarms, trip target indications and fault status information. Enhanced MicroVersaTrip Plus and MicroVersaTrip PM trip units use GE’s proven technique of measuring true rms currents (and voltages for MicroVersaTrip PM trip units) of both sinusoidal and harmonically distorted waveforms. The frequent sampling (64 times per cycle) allows precise calculations of true rms current. The sam- pling rate allows allows waveform measurements up to the 31st harmonic to achieve accuracies of 99%. GE’s true rms sensing avoids potential underprotection or overprotection problems associated with peak- sensing tripping systems. The enhanced trip unit design includes a wide range of functions and adds many new features:
Trip operations counter —The number of long-time, short-time, instantaneous and ground fault trips are individually counted and displayed.
Enhanced MicroVersaTrip Plus and MicroVersaTrip PM Trip Units have been specifically designed to integrate with the extensive capabilities offered by Power Break circuit breakers.
Features exclusive to MicroVersaT MicroVersaTrip rip PM Tri Trip p Units
Trip information Communications —On overcurrent faults, the trip unit displays fault pickup, the type —All information can be viewed on the LCD display or of fault, the magnitude of the fault current and the phase the communicated over a POWER LEADER Power fault occurred on. Management Managem ent System network. network. New display —Ergonomic, 5-button keypad —New targets with international symbols —High-resolution LCD display for local 3-phase ammetering —New status and setup displays for greater ease of use —True rms sensing for accurate response to high harmonic
Demand/peak demand —The trip unit can display a rolling average of power demand and peak power demand at user-selected user-selected intervals from 5 to 60 min minutes utes
content waveforms for Long-Time, Short-Time, and Ground Fault protect protection. ion. —50/60 Hz operation. —Interchangeable, UL Listed trip units and rating plugs with test set jack for TVRMS2 TVRMS2 test set. —EMI immunity per ANSI C37.90.
Local and remote metering —Amperes, volts, frequency —Real power, total power —Accumulated energy Protective relays include —Current and voltage unbalance —Overvoltage —Undervoltage —Power reversal —Power reversal direction setup
distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
5-36
BuyLog Catalog
www.geelectrical.com
Rev. 12/04
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break I Circuit Breakers with Enhanced MicroVersaTrip Plus and MicroVersaTrip PM Trip Units
S E R S E A K C A E D R E B T T A I L U U C S R I N I C
Technical Data Trip Unit Characteristics
Enhanced MicroVersaTrip Plus and PM Tri Trip p Unit Characteristics Long-Time Sensor Rating (Amperes) (S)
Frame Rating Max. Envelope Size Ampere
Setting (C) (Pick-Up) MulCurrent Multipl tiple e of of Rati R ating ng Plug Ampere Amp eres s (X) (X)
Short-Time Delay Del ay 1 (Seconds)
800
800
200, 400, 800
2.4, 4.9, 9.8, 20
1600
1600
1000, 1600
2.4, 4.9, 9.8, 20
2000
2000
2000
2500
1000, 2000, 2500
3000
3000
4000
4000
3000 4000
of Pick-Up Curr Cu rren entt (Multiple Setti Set ting ng)) (C (C))
Dela De lay y (S (Sec econ onds ds) ) I 2 T in 1 0.40
2.4, 4.9, 9.8, 20
0.5 thru 1.0 in increments of 0.05
1.5 thru 9.0 in increments of 0.05
2.4, 4.9, 9.8, 20
I2 T out2 .10, .21, .35
2.4, 4.9, 9.8, 20
Trip Unit Characteristics (continued) Adjustable Instantaneous Pick-Up without ST (Multiple of Envelope Size Rating Plug Amperes) (X)
Adjustable Instantaneous Pick-Up with ST (Multiple of Rating Plug Amperes) (X)
High Range Instantaneous (Multiple of Frame Short-Time Rating) (H)
Ground Fault Pick-Up (Multiple of Sensor Ampere Rating)
1.5 thru 10.0 in 0.5 increments
1.5 thru 15.0 in 0.5 increments
1.5 thru 10.0 in
1.5 thru 15.0 in
0.20 thru 0.60 in
2000
0.5 increments 1.5 thru 10.0 in 0.5 increments
0.5 increments 1.5 thru 15.0 in 0.5 increments
increments of 0.01 0.20 thru 0.60 in increments of 0.01
3000
1.5 thru 10.0 in 0.5 increments
1.5 thru 13.0 in 0.5 increments
0.20 thru 0.37 in increments of 0.01
4000
1.5 thru 9.0 in 0.5 increments
1.5 thru 9.0 in 0.5 increments
0.20 thru 0.30 in increments of 0.01
800 1600
Delay with I 2 T Seconds
0.20 thru 0.60 in increments of 0.01
1.0
Delay 3 wit witho hout ut I 2 T Seconds .10, .21, .35 .10, .21, .35
.37 at 200% of pick-up at lower limit of band
.10, .21, .35 .10, .21, .35 .10, .21, .35
1 Time delay shown at 600% of current setting at lower limit of band. 2 Time delay shown at lower limit of each band. All pick-up tolerances are ± 10%. 3 Time delay shown at lower limit of each band. Ground fault pick-up not to exceed 1200 amperes.
X = Rating plug amperes S = Sensor ampere rating C = Long-time current setting (pick-up) H = Short-time rating
MicroVersaTrip PM Trip Unit Characteristics 4 Trip Unit Suffix Function Communications
Description —POWER LEADER Communications Bus Link
M (Metering)
P (Relaying)
PM (Metering & Relaying)
STD
STD
STD
STD
STD
STD
Amperes (A, kA)5
Selectable Phase Current ±2.5%
Voltage (V)
L-L or L-N Volts ±1.5%
•
•
Energy (kWh, MWh, GWh)
Total Energy Usage on Brkr ±4%
•
•
Real Power (kW/MW)
L-L or L-N Power ±4%
•
•
Total Power (kVA/MVA)
L-L or L-N Power ±4%
•
•
Frequency (Hz)
Circuit Frequency ± 1Hz
•
•
•
•
Demand & Peak Demand (kW) Under Voltage Trip
—Adjustable pickup 50-90% —Adjustable delay, 1-15 seconds OFF
•
•
Over Voltage Trip
—Adjustable pickup, 110-150% —Adjustable delay, 1-15 seconds OFF
•
•
Voltage Unbalance
—Adjustable pickup, 10-50% —Adjustable delay, 1-15 seconds OFF
•
•
Current Unbalance
—Adjustable pickup, 10-50% —Adjustable delay, 1-15 seconds OFF
•
•
Power Reversal
—Adjustable pickup, 10-990 kW —Adjustable delay, 1-15 seconds OFF
•
•
4 MicroVersaTrip PM functions require 24 Vdc control power. 5 Ampere reading also standard on MicroVersaTrip Plus.
Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
5
www.geelectrical.com
Rev. 12/04
BuyLog Catalog
5-37 Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break I Circuit Breakers with MagneTrip Unit S E R S E A K C A E D R E B T T A I L U U C S R I N I C
How To Order Stationary Breakers and Special Purpose Hi-Break
Power Break Breaker with MagneTrip Trip Unit—Stationary, UL Listed, 100% Equipment Rated
GO-145M
600 Vac, 250 Vdc (Standard Break), 600 Vdc 1 (Hi-Break) Non-interchangeable Trip Unit Circuit Breaker Envelope Size (Amperes)
Circuit Breaker Frame Size (Amperes)
5 160 0
40 00
160 0
400 0
Continuous Current Rating (Amperes)
Standard Break Product Number 2
200
TPMM5602
$13890.00
THPMM5602
$14887.00
400
TPMM5604
THPMM5604
TPMM5606
$13890.00 $13890.00
600
THPMM5606
$14887.00 $14887.00
Hi-Break Product Number 2
List Price
List Price
800
TPMM5608
$13890.00
THPMM5608
$14887.00
1000
TPMM5610
$13890.00
THPMM5610
$14887.00
1200
TPMM5612
$13890.00
THPMM5612
$14887.00
1600 40 0 0
TPMM5616 TPMM96402
$13890.00
THPMM5616 THPMM96402
$14887.00
$60399.00
$73666.00
3000 30 00 Am Ampe pere re En Enve velo lope pe Si Size ze Po Powe werr Bre Break ak wi with th Ma Magne gneT Tri rip p Tri Trip p Uni Unit— t—St Stat atio ionar naryy, UL UL Lis Liste ted, d, 10 100% 0% Eq Equi uipm pmen entt Rat Rated ed
GO-1 GO -145 45M M
600 Vac, 250 Vdc (Standard Break), 600 Vdc (Hi-Break) Interchangeable Trip Unit Circuit Breaker Frame Size (Amperes)
Continuous Current Rating (Amperes)
250 0
30 0 0
Standard Break Complete Product Number 2
60 0
TPMM7606
Hi-Break Complete Product Number 2
List Price
$14988.00
THPMM7606
List Price
$18902.00
80 0
TPMM7608
$14988.00
THPMM7608
$18902.00
100 0
TPMM7610
THPMM7610
TPMM7612
$14988.00 $14988.00
120 0
THPMM7612
$18902.00 $18902.00
$14988.00 $14988.00
THPMM7616
THPMM7620
$18902.00 $18902.00
160 0
TPMM7616
20 00
TPMM7620
250 0
TPMM7625
$28484.00
THPMM7625
$36538.00
300 0
TPMM8630
$37577.00
THPMM8630
$46381.00
Speciall Hi-Bre Specia Hi-Break ak Power Break Breake Breakerr with with MagneT MagneTrip rip Trip Unit Unit—Stat —Stationary ionary
GO-145M GO-1 45M
750 Vac, 700 Vdc, Interchangeable Trip Unit, Not UL Listed Circuit Breaker Envelope Size (Amperes)
30 00
Circuit Breaker Frame Size (Amperes)
250 0
30 0 0
Continuous Current Rating (Amperes)
Complete Product Number 2
60 0
TUPMM7706
List Price
$21579.00
80 0
TUPMM7708
$21579.00
100 0
TUPMM7710
$21579.00
120 0
TUPMM7712
$21579.00
160 0
TUPMM7716
$21579.00
20 00
TUPMM7720
$21579.00
250 0
TUPMM7725
$41660.00
30 00
TUPMM8730
$52905.00
3,4
40 00
40 0 0
40 00
$84039.00
TUPMM9740
Power Break Breaker with Instantaneous Only—Stationary
GO-145M
600 Vac, 250 Vdc, Non-Interchangeable Trip Unit, Not UL Listed Circuit Breaker Envelope Size (Amperes)
Circuit Breaker Frame Size (Amperes)
Continuous Current Rating (Amperes)
1600
1600
160 0
TPMM5616M
$13890.00
250 0
20 00
TPMM7620M
$14988.00
250 0
250 0
TPMM7625M
$28484.00
30 0 0
30 00
TPMM8630M
40 0 0
40 00
TPMM9640M2
$37577.00 $60399.00
30 00 40 00
Standard Break Product Number
List Price
14000-Ampere frame only 2 Product Number with standard trip functions. For optional trip functions and pricing, see page 5-39. 3 80% rated 4 Non-interchangeable trip
distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
5-38
BuyLog Catalog
www.geelectrical.com
Rev. 12/04
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break I Circuit Breakers with Magne Trip Trip Unit How To Order Stationary Breakers, Draw-Out Breakers
Power Break Breaker with MagneTrip Trip Unit—Draw-Out UL Listed, 100% Equipment Rated
S E R S E A K C A E D R E B T T A I L U U C S R I N I C
GO-145M
600 Vac, 250 Vdc (Standard Break), 600 Vdc 1 (Hi-Break) Non-Interchangeable Trip Unit Circuit Breaker
Circuit Breaker
Continuous
Standard Break
Hi-Break 2
Envelope Enve lope Size (Ampe (Amperes) res)
160 0
40 0 0
Frame Fram e Size (Ampe (Amperes) res) Curr Current ent Rating (Ampe (Amperes) res) 20 0 40 0 60 0 160 0 80 0 10 0 0 120 0 160 0 40 0 0 40 0 0
2
Product Numbe Product Number r TCMM5602 TCMM5604 TCMM5606 TCMM5608 TCMM5610 TCMM5612 TCMM5616 TCMM9640
Li st st P ri ri ce ce
$17187.00
$17187.00
$17187.00
$17187.00
$17187.00
$17187.00
$17187.00
$71014.00
P ro ro du du ct ct N um umb er er THCMM5602 THCMM5604 THCMM5606 THCMM5608 THCMM5610 THCMM5612 THCMM5616 THCMM9650
List Price
3000 30 00 Am Ampe pere re Env Envel elop ope e Siz Size e Pow Power er Br Brea eak k Bre Break aker er wi with th Ma Magn gneT eTri rip— p—Dr Draw aw-O -Out ut,, UL UL Lis Liste ted, d, 100 100% % Equ Equip ipme ment nt Ra Rate ted d
$18450.00
$18450.00
$18450.00
$18450.00
$18450.00
$18450.00
$18450.00
$86462.00
5
GO-1 GO -145 45M M
600 Vac, 250 Vdc (Standard Break), 600 Vdc (Hi-Break) Interchangeable Trip Unit Circuit Breaker Frame Size (Amperes)
2500
– 30 0 0
Continuous Current Rating (Amperes)
Standard Break Complete Product Number 2
60 0 80 0 10 0 0 120 0 160 0 20 0 0 250 0 30 0 0
TCMM7606 TCMM7608 TCMM7610 TCMM7612 TCMM7616 TCMM7620 TCMM7625 TCMM8630
Hi-Break Complete Product Number 2
List Price
$19814.00
$19814.00
$19814.00
$19814.00
$19814.00
$19814.00
$33702.00
$43859.00
THCMM7606 THCMM7608 THCMM7610 THCMM7612 THCMM7616 THCMM7620 THCMM7625 THCMM8630
List Price
$24096.00
$24096.00
$24096.00
$24096.00
$24096.00
$24096.00
$42143.00
$53114.00
Optional MagneTrip Unit Functions 3
GO-145M 4
Description
Product No. Suffix
Adjustable current plus adjustable short-time fixed instantaneous Inverted construction (stationary breaker only)
D B
List Price Adder
$1075.00
$1244.00
Replacement MagneTrip Trip Units Continuous Current Rating (Amperes) 60 0 80 0 10 0 0 120 0 160 0 20 0 0 250 0 30 0 0
GO-148F
Replacement Trip Unit Product Number TPD706 TPDT08 TPDT10 TPDT12 TPDT16 TPDT20 TPDT25 TPDT30
Adjustable Current, Short-Time, Fixed Instantaneous
List Price
$4497.00
$4497.00
$4497.00
$4497.00
$4497.00
$4497.00
$8544.00 $11272.00
TPDT06D TPDT08D TPDT10D TPDT12D TPDT16D TPDT20D TPDT25D TPDT30D
14000-Ampere frame only 2 Product Number with standard trip functions. For optional trip functions see table. 3 Add suffix code letter to end of breaker frame product numbers. 4 For trip option on new breaker, add to complete breaker list price above.
Publications and Reference: See Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
Inverted Construction (Stationary Only)
List Price
$5572.00
$5572.00
$5572.00
$5572.00
$5572.00
$5572.00
$9619.00 $12347.00
TPDT06B TPD708B TPDT10B TPDT12B TPDT16B TPDT20B TPDT25B TPDT30B
List Price
$5741.00
$5741.00
$5741.00
$5471.00
$5471.00
$5471.00
$9788.00 $12516.00
www.geelectrical.com
Rev. 12/04
BuyLog Catalog
5-39 Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break I Circuit Breakers with MicroVersaTrip Plus or PM Trip Units S E R S E A K C A E D R E B T T A I L U U C S R I N I C
5
Frame Selection Basic Frame Selection, Stationary, UL Listed, 100% Equipment Rated, Suitable for Reverse Feed
GO-145C
Frame Selection for Use with MicroVersaTrip Plus Trip Units Only Circuit Breaker Envelope Size (Amperes)
Circuit Breaker Frame Size (Amperes)
Sensor Rating (Amperes)
80 0 80 0 80 0 160 0 160 0 20 0 0 30 0 0 30 0 0 30 0 0 30 0 0 40 0 0
80 0 80 0 80 0 160 0 160 0 20 0 0 250 0 250 0 250 0 30 0 0 40 0 0
20 0 40 0 80 0 10 0 0 160 0 20 0 0 10 0 0 20 0 0 250 0 30 0 0 40 0 0
Standard Break 1
Product Number
Hi-Break 1 Product Number
List Price
TP82TT TP84TT TP88TT TP1610TT TP1616TT TP2020TT TP2510TT TP2520TT TP2525TT TP3030TT TP4040T2
$13815.00
$13815.00
$13815.00
$16890.00
$16890.00
$17917.00
$19710.00
$19710.00
$34750.00
$44230.00 $72945.00
List Price
THP82TT THP84TT THP88TT THP1610TT THP1616TT THP2020TT THP2510TT THP2520TT THP2525TT THP3030TT THP4040T2
$14950.00
$14950.00
$14950.00
$18779.00
$18779.00
$20985.00
$23085.00
$23085.00
$43540.00
$55435.00 $88990.00
Frame Selection 3 for Use with MicroVersaT MicroVersaTrip rip PM or Plus Trip Units Standard Break 1
Circuit Breaker Envelope Size (Amperes)
Circuit Breaker Frame Size (Amperes)
Sensor Rating (Amperes)
80 0 80 0 80 0 160 0 160 0 20 0 0 30 0 0 30 0 0
80 0 80 0 80 0 160 0 160 0 20 0 0 250 0 250 0
20 0 40 0 80 0 10 0 0 160 0 20 0 0 10 0 0 20 0 0
TP82TTR TP84TTR TP88TTR TP1610TTR TP1616TTR TP2020TTR TP2510TTR TP2520TTR
30 0 0 30 0 0 40 0 0
250 0 30 0 0 40 0 0
250 0 30 0 0 40 0 0
TP2525TTR TP3030TTR TP4040TR2
Product Number
Hi-Break 1 Product Number
List Price
$14305.00
$14305.00
$14305.00
$17375.00
$17375.00
$18405.00
$20200.00
$20200.00
$35235.00 $44715.00 $73430.00
List Price
THP82TTR THP84TTR THP88TTR THP1610TTR THP1616TTR THP2020TTR THP2510TTR THP2520TTR
THP2525TTR THP3030TTR THP4040TR2
$15440.00
$15440.00
$15440.00
$19270.00
$19270.00
$21475.00
$23570.00
$23570.00
$44030.00 $55920.00 $89480.00
Basic Frame Selection, Draw-Out, UL-Listed, 100% Equipment Rated, Suitable for Reverse Feed
GO-145C
Frame Selection for Use with MicroVersaTrip Plus Trip Units Only Circuit Breaker Envelope Size (Amperes)
Circuit Breaker Frame Size (Amperes)
Sensor Rating (Amperes)
Standard Break 1
Product Number
Hi-Break 1
List Price
Product Number
List Price
$16300.00
THC82TT4,5
$17475.00
TC84TT4,5 TC88TT4,5 TC1610TT TC1616TT TC2020TT TC2510TT TC2520TT TC2525TT TC3030TT
$16300.00
THC84TT4,5 THC88TT4,5 THC1610TT THC1616TT THC2020TT THC2510TT THC2520TT THC2525TT THC3030TT
$17475.00
THC4040T T
80 0 80 0 80 0 160 0 160 0 20 0 0 30 0 0 30 0 0 30 0 0 30 0 0
80 0 80 0 80 0 160 0 160 0 20 0 0 250 0 250 0 250 0 30 0 0
20 0 40 0 80 0 10 0 0 160 0 20 0 0 10 0 0 20 0 0 250 0 30 0 0
TC82TT4,5
40 0 0
40 0 0
40 0 0
TC4040T T
$24295.00
$24295.00
$41940.00
$52485.00
$87415.00
$16300.00
$21175.00
$21175.00
$22090.00
$17475.00
$23420.00
$23420.00
$25575.00
$28130.00
$28130.00
$51595.00
$64690.00
$106070.00
Frame Selection 3 for Use with MicroVersaTrip PM or Plus Trip Units Circuit Breaker Envelope Size (Amperes)
Circuit Breaker Frame Size (Amperes)
Sensor Rating (Amperes)
80 0 80 0 80 0 160 0 160 0 20 0 0 30 0 0 30 0 0 30 0 0 30 0 0 40 0 0
80 0 80 0 80 0 160 0 160 0 20 0 0 250 0 250 0 250 0 30 0 0 40 0 0
20 0 40 0 80 0 10 0 0 160 0 20 0 0 10 0 0 20 0 0 250 0 30 0 0 40 0 0
Standard Break 1
Product Number
TC82TTR4,5 TC84TTR4,5 TC88TTR4,5 TC1610TTR TC1616TTR TC2020TTR TC2510TTR TC2520TTR TC2525TTR TC3030TTR TC4040TTR
Hi-Break 1 Product Number
List Price $16785.00 $16785.00 $16785.00
$21660.00
$21660.00
$22380.00 $24785.00
$24785.00
$42430.00
$52975.00
$87905.00
THC82TTR4,5 THC84TTR4,5 THC88TTR4,5 THC1610TTR THC1616TTR THC2020TTR THC2510TTR THC2520TTT THC2525TTR THC3030TTR THC4040TTR
List Price $17965.00 $17965.00 $17965.00
$23910.00
$23910.00
$26060.00 $28615.00
$28615.00
$52080.00
$65180.00 $106555.00
1For frame modification, i.e. electrically operated, see page 5-42. 2 Not rated 100%. 3 Includes provision for MicroVersaTrip MicroVersaTrip PM functions. Use for MicroVersaTrip MicroVersaTrip Plus when connections for 24 Vdc trip unit control power required. 4
to 24 secondary disconnects. For up to 48 secondary disconnects, use Product Number TCL-TT or TCL-TTR and add $1600.00 to List Price. 5 Up Small frame size.
distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
5-40
BuyLog Catalog
www.geelectrical.com
Rev. 12/04
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break I Circuit Breakers Stationary Switches, Draw-out Switches 800-4000 Amperes 600 Vac 500 Vdc (250 Vdc where noted) Suitable for reverse feed Power Break Molded Case Switch—Stationary
GO-145D
600 Vac, 500 Vdc (Standard Break), 600 Vdc (Hi-Break) Switch Envelope Size (Amperes)
Switch Frame Size (Amperes)
Continuous Current Rating (Amperes)
Standard Break 600 Vac/500 Vdc
List Price
80 0
80 0
80 0
TPYY36081
$5671.00
–
–
$7452.00
–
–
$8380.00
–
160 0
160 0
160 0
TPYY56161
20 0 0
20 0 0
20 0 0
TPYY66201
30 0 0
250 0
20 0 0
TPYY7620
Hi-Break 600 Vac/600 Vdc
List Price
–
$8380.00
THPYY7620
$10481.00
30 0 0
250 0
250 0
TPYY7625
$13335.00
THPYY7625
$16670.00
30 0 0
30 0 0
30 0 0
TPYY8630
$22565.00
THPYY8630
$28204.00
40 0 0
40 0 0
40 0 0
TPYY9640
$35794.00
THPYY9640
$44738.00
Power Break Molded Case Switch—Draw-Out
GO-145D
600 Vac, 500 Vdc (Standard Break), 600 Vdc (Hi-Break) Switch Envelope Size (Amperes)
Switch Frame Size (Amperes)
Continuous Current Rating (Amperes)
Standard Break 600 Vac/500 Vdc
Hi-Break 600 Vac/600 Vdc
List Price
List Price
80 0
80 0
80 0
TCYY36081
$7384.00
–
–
160 0
160 0
160 0
TCYY56161
$10751.00
–
–
20 0 0
20 0 0
20 0 0
TCYY66201
$11683.00
–
–
30 0 0
250 0
20 0 0
TCYY7620
THCYY7620
30 0 0
250 0
250 0
TCYY7625
$13205.00 $18552.00
THCYY7625
$15304.00 $21889.00
30 0 0
30 0 0
30 0 0
TCYY8630
$28843.00
THCYY8630
$34482.00
40 0 0
40 0 0
40 0 0
TCYY9640
$46411.00
THCYY9640
$55355.00
1Rated 250 Vdc
Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
S E R S E A K C A E D R E B T T A I L U U C S R I N I C
5
www.geelectrical.com
Rev. 12/04
BuyLog Catalog
5-41 Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break I Circuit Breakers S E R S E A K C A E D R E B T T A I L U U C S R I N I C
5
Frame Modification Features
Power Break Frame Modification Suffix—AC and DC Breakers
GO-145C
Circuit Breaker Envelope Size (Amperes) Function 1
Electrical (Motor) Operation 2
800
1600
2000
3000
120 Vac 240 Vac
E1 N/A
E1 N/A
E1 N/A
125 Vdc
E3
E3
24 Vdc
E5
48 Vdc
E6
72 Vdc
E7
Front Connected
4000
List Price Adder
E1 E2 3
E1 E2 3
$4475.00 $4930.00
E3
E3
E3
$4930.00
E5
E5
E5
E5
$4930.00
E6
E6
E6
E6
$4930.00
E7
E7
E7
E7
$5380.00
Suitable for front or rear connection as standard
Add suffix FC Supplied as to Product No.4 standard
No price adder
Hidden "ON" Button
Add suffix C to frame Product Number
$148.00
High Range Instantaneous (Air Core Sensors)
Add suffix H to frame Product Number 5
Price adder is on trip unit only
Add suffix Z to frame Product Number when zone interlock function is included in trip unit (Z1 or Z2). Requires 24 Vdc Control power.
Price adder is on trip unit only
Zone Selective Interlock Wiring Terminal Block
TC3030TT
1 Modification suffix must be developed in the following order: H/Z/FC/E1-7/C, ending with R:
TP82TTE1CR. 2 Shunt trip or undervoltage release included with motor operation (specify with order). 3 Not UL Listed. 4 Stationary frames only. 5 Not available on 4000A stationary b reakers.
distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
5-42
BuyLog Catalog
www.geelectrical.com
Rev. 12/04
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break I Circuit Breakers with Enhanced MicroVersaTrip Plus and MicroVersaTrip PM Trip Units
S E R S E A K C A E D R E B T T A I L U U C S R I N I C
How To Order Trip Unit Characteristics and Selection Power Break Basic MicroVersaTrip MicroVersaTrip Tri Trip p Unit Selection Circuit Breaker Envelope Size (Amperes)
Circuit Breaker F ra ra me me Siz Size e (Am (Ampe pere res) s)
800
200
C202
400
C204
800
C208
1000
C210
1600
C216
2000
C220
1000
C210
2000
C220
2500
C325
3000
3000
C330
4000
4000
C440
800
1600
Basic Trip Unit Product Number
Sens Se nsor or Ra Rati ting ng (A (Amp mpe e re re s) s)
5
1600
2000
2000
2500 3000
4000
Power Break Trip Unit Suffix Selection MicroVersaTrip MicroVersaT rip Plus with Selectable Phase Ammeter—Trip Indicators Standard Trip Unit Suffix 1
List Price Adder, GO-145C 1
Trip Indicators
Selectable Phase Ammeter
Long-Time (L)
Short-Time (S)
Inst. (I)
High Inst. (H)
Ground 2 Fault 3 GF Zone (G) Interlock (Z1) 4
GF/ST Zone Interlock (Z2) 4
Adjustable Instantaneous LI LIG
$690.00
•
•
•
•
$2205.00
•
•
•
•
•
$2875.00
•
•
•
•
•
$2260.00
•
•
•
•
•
$3772.00
•
•
•
•
LIGZ1 LSI
•
•
LSIGZ1
$4445.00
•
•
•
•
•
•
LSIGZ2
$5120.00
•
•
•
•
•
•
LSIG
•
• •
Fixed High Range Instantaneous 5 LSH LSHG
1
$3105.00
•
•
•
•
•
$4310.00
•
•
•
•
•
•
LSHGZ1
$5290.00
•
•
•
•
•
•
LSHGZ2
$5965.00
•
•
•
•
•
•
• •
Add suffix to basic trip unit product number. Make List Price addition for trip unit suffix.
2 For 3
single-phase 3-wire or 3-phase, 4-wire application s, order appropriate neutral current sensor and price separately from page 5-46. Use code GD in place of G for a defeatable Ground Fault Option (not UL listed) i.e. LSIGD, and add $575.00 to list price. 4 Requires purchase of zone selective interlock module(s) TypeTIM1 (120 Vac Vac control voltage). List Price $402.00, GO-245B. 5 Not available on 400 0A stationary breaker frame. Requires frame with "H" suffix code. See page 5-40.
Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
www.geelectrical.com
Rev. 12/04
BuyLog Catalog
5-43 Prices and data subject to change without notice
Insulated Case Circuit Breakers
S E R S E A K C A E D R E B T T A I L U U C S R I N I C
Power Break I Circuit Breakers with Enhanced MicroVersaTrip Plus and MicroVersaTrip PM Trip Units How To Order Trip Tri p Unit Characteristics and Selection (continued) Power Break Trip Unit Suffix Selection MicroVersaTrip MicroVersaT rip PM with Metering and Communications—T Communications—Trip rip Indicators Standard 1 Trip Unit 2 Suffix 2
List Price Adder, GO-145C 2
Trip Indicators
Selectable Phase Ammeter
Long-Time (L)
Short-Time (S)
Inst. (I)
Ground Gro und Fau Fault lt 4 (G) 4
High Inst. (H)
GF Zone Interlock (Z1) 5
GF/ST Zone Interlock (Z2) 5
Adjustable Instantaneous
LIM
5
$2415.00
LIGM
LIGZ1M
LSIM
LSIGM
•
•
•
•
$3930.00
•
•
•
•
•
$4600.00
•
•
•
•
•
$3985.00
•
•
•
•
•
$5497.00
•
•
•
•
•
•
•
•
•
•
•
•
•
LSIGZ1M
$6170.00
•
LSIGZ2M
$6845.00
•
•
•
•
$4830.00
•
•
•
•
•
$6345.00
•
•
•
•
•
•
• •
Fixed High Range Instantaneous 6
LSHM
LSHGM LSHGZ1M
$7015.00
•
•
•
•
•
LSHGZ2M
$7690.00
•
•
•
•
•
• •
•
Power Break Trip Unit Suffix Selection MicroVersaTrip MicroVersaT rip PM with Protective Relays and Communications—T Communications—Trip rip Indicators Standard 1 Trip Unit Suffix 2
List Price Adder, GO-145C 2
Trip Indicators
Selectable Phase Ammeter
Long-Time (L)
Short-Time (S)
Inst. (I)
High Inst. (H)
Ground 3 Fault (G) 4
GF Zone Interlock (Z1) 5
GF/ST Zone Interlock (Z2) 5
Adjustable Instantaneous LIP
LIGP
$1955.00
LIGZ1P LSIP
•
•
•
•
$3470.00
•
•
•
•
•
•
•
$4140.00
•
•
•
$3525.00
•
•
•
•
•
$5037.00
•
•
•
•
•
•
LSIGZ1P
$5710.00
•
•
•
•
•
•
LSIGZ2P
$6385.00
•
•
•
•
•
•
$4370.00
•
•
•
•
•
$5885.00
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
LSIGP
•
• •
Fixed High Range Instantaneous 6 LSHP
LSHGP LSHGZ1P
$6555.00
•
LSHGZ2P
$7320.00
•
• •
Power Break Trip Unit Suffix Selection MicroVersaTrip MicroVersaT rip PM with Metering, Protective Relays and Communications—T Communications—Trip rip Indicators Standard 1 Trip Unit Suffix 2 2
List Price Adder, GO-145C 2 GO-145C 2
Trip Indicators
Selectable Phase Ammeter
Long-Time (L)
Short-Time (S)
Inst. (I)
High Inst. (H)
Grou Gr ound nd Fa Faul ultt (G) 4 4
GF Zone Interlock (Z1) 5 (Z1) 5
GF/ST Zone Interlock (Z2) 5 (Z2) 5
Adjustable Instantaneous LIPM
LIGPM
$3680.00
LIGZ1PM LSIPM LSIGPM
•
•
•
•
$5265.00
•
•
•
•
•
$5865.00
•
•
•
•
•
$5250.00
•
•
•
•
•
$6762.00
•
•
•
•
•
•
LSIGZ1PM
$7435.00
•
•
•
•
•
•
LSIGZ2PM
$8110.00
•
•
•
•
•
•
•
• •
Fixed High Range Instantaneous 6 LSHPM
$6095.00
•
•
•
•
•
$7610.00
•
•
•
•
•
•
LSHGZ1PM
$8280.00
•
•
•
•
•
•
LSHGZ2PM
$8955.00
•
•
•
•
•
•
LSHGPM
• •
1
Requires 24 Vdc control power and frame with TT…R suffix. See page 5-40 . Add suffix to basic trip unit product number. Make List Price addition for for trip unit suffix. Requires frame with TT…R suffix. See page 5-40. 3 For single-phase 3-wire or 3-phase, 4-wire applications, order appropriate neutral current sensor and price separately from page 5-46. 2
4
code GD in place of G for defeatable Ground Fault Option (not UL listed) i.e. LSIGDPM, and add $575.00 to List Price. Requires purchase of zone selective interlock module(s) TypeTIM1 (120 Vac control voltage). List Price $402.00, GO-245B. Not available on 400 0A stationary breaker frame. Requires frame with "H" suffix code. See page 5-40.
5 Use 6
distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
5-44
BuyLog Catalog
www.geelectrical.com
Rev. 12/04
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break I Circuit Breakers How To Order Rating Plug Selection Power Break Rating Plus Selection 1 All Plugs List Priced at $89.00 Frame Size (Amperes)
Sensor Rating (Amperes)
GO-245A Current Rating (Amperes)
Rating Plug Product Number
100
TR2B100
20 0
400 800
80 0
1000
1600
1600
20 00
200 0
1000
2500
200 0
250 0
30 00
300 0
40 00
400 0
1Rating plug removal tool. Product Number TRTOOL,
150 200 150 200 225 250 300 400 300 400 450 500 600 700 800 400 600 800 1000 60 0 800 1000
TR2B150 TR2B20 0 TR4B150 TR4B20 0 TR4B225 TR4B250 TR4B30 0 TR4B40 0 TR8B30 0 TR8B40 0 TR8B450 TR8B50 0 TR8B60 0 TR8B70 0 TR8B80 0 TR10B400 TR10B600 TR10B800 TR10B100 0 TR16B60 0 TR16B80 0 TR16B1000
110 0 1200 1600 750 800 1000 1200 1500 1600 200 0 400 600 800 1000 750 800 1000 1200 1500 1600 200 0 1600
TR16B110 0 TR16B120 0 TR16B160 0 TR20B750 TR20B800 TR20B1000 TR20B1200 TR20B1500 TR20B1600 TR20B200 0 TR10B400 TR10B600 TR10B800 TR10B100 0 TR20B750 TR20B800 TR20B1000 TR20B1200 TR20B1500 TR20B1600 TR20B200 0 TR25B1600
200 0 250 0 1200 1600 200 0 250 0 300 0 1600 200 0 250 0 300 0 360 0 400 0
TR25B200 0 TR25B2500 TR30B1200 TR30B1600 TR30B200 0 TR30B2500 TR30B300 0 TR40B1600 TR40B200 0 TR40B2500 TR40B300 0 TR40B3600 TR40B400 0
$12.00, GO-135S .
Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
S E R S E A K C A E D R E B T T A I L U U C S R I N I C
5
www.geelectrical.com
Rev. 12/04
BuyLog Catalog
5-45 Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break I Circuit Breakers S E R S E A K C A E D R E B T T A I L U U C S R I N I C
Neutral Current Sensors and POWER LEADER Accessories
Neutral Current Sensors 1 Circui Circ uitt Bre Break aker er Sensor Rating (Amperes)
Breaker Frame (Amperes)
800
5
800-1600 1600
2000
3000
4000
GO-245B Neutra Neut rall Sen Senso sor r Rating or Tap Settings (A (Amperes)
200
200
400 400 800 1000 1000 1600 1600 200 0 1000 1000 1000 1000 200 0 250 0 300 0 400 0
400/200 600/30 02 800/400 800/40 02 10 00/50 0 120 0/60 02 1600/100 0 2000/10 00 800/40 02 10 00/50 0 120 0/60 02 160 0/10002 2000/1200 2500/1800 30 00/2400 40 00/3000
Product Number TSVG302 TSVG304A TSVG306A TSVG308A TSVG808A TSVG810A TSVG812A TSVG816A TSVG820A TSVG808A TSVG810A TSVG812A TSVG816A TSVG820A TSVG825A TSVG830A TSVG940A
List Pr Price
$266.00
$266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00
1Match neutral current sensor rating (or tap setting) to circuit breaker sensor rating. 2 For use with multiple source ground fault protection schemes. Rating does not match
MicroVersaTrip MicroVersaT rip Plus or PM frame sensor.
MicroVersaTrip Portable Test Kit
GO-245B
The test kit product number TVRMS2 is a portable, battery-powered, test kit which provides for trip unit health checks and functional trip and no-trip tests. It also provides defeat of the ground-fault function and can be used in conjunction with high-current test equipment. The test kit can be used to provide +24V power to the trip unit for cold set-up and viewing of trip targets. This test kit is for use with RMS-9, Epic, MicroVersaTrip Plus and MicroVersaTrip MicroVersaTrip PM trip units. The kit uses six rechargeable ni-cad or standard alkaline "D" cells supplied by the customer. Kit can also be powered by 120 Vac source. Description
Product Number
Portable Test Kit
TVRMS2
Neutral Current Sensor
POWER LEADER Power Supplies
G0-104A
Power supply for furnishing 24Vdc control power for MicroVersaTrip Plus and PM trip units. Two versions are available: a 4.0 ampere ver- sion with AC and DC input voltages and a 0.8 ampere version capa- ble of operating from 120/230 Vac. Both power supplies have inher- ent transient protection circuits. System Requirements Description
(price separately)
4.0 ampere power supply Price one PLPS4G01 for each eac h lin line-up e-up.. 60 trip uni units ts and 100 ft. maxi maximum mum..
Input Inp ut pow power er,, 100V 100VA A (85-265Vac (85-265V ac or 100100-370V 370Vdc) dc)
Product Number
List Price
PLPS4G0 PLP S4G01 1 $1250.00
Reference Instructions
GEH-5946
POWER LEADER Voltage Conditioner
G0-104A
List Price
$3000.00
Conditions and scales 120 Vac to 1.76 Vac for use by the trip unit for
MicroVersaTrip Portable Power Pack
GO-245B
The handheld MicroVersaTrip portable battery pack provides an independent power source for Enhanced MicroVersaTrip Plus and MicroVersaTrip PM trip units as an alternative to the TVRMS2 test set. The power pack is used to power up the trip unit to set or adjust trip set points when the breaker is on the bench or otherwise not powered up. It connects to the trip unit through the rating plug test jack. It requires three (3) ( 3) standard 9Vdc alkaline batteries (not included). Product number TVPBP List Price, $75.00, GO-245A. Description MicroVersaTrip Plus and PM Portable Power Pack
Product Number
List Price
voltage sensing. Provides transient protection. Voltage conditioners require isolation PTs PTs.. Description
System Re Requirements (price separately)
Supplies isolated bus voltage vol tage sig signal nal to MicroVersaTrip PM trip tr ip un unit its. s.
One set of 3 vol voltage tage con conditi ditioner oners s required for each voltage sensing loca lo cati tion on.. PT PTs s al also so re requ quir ired ed..
Rating Plug Removal Tool
$75.00
TRTOOL
List Price
$200.00 PLVC VC1G 1G01 01 per set
GO-135S
Product Number TVPBP
Product Number
List Price
$12.00
distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
5-46
BuyLog Catalog
www.geelectrical.com
Rev. 12/04
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break I Circuit Breakers Stationary and Draw-out Breaker Accessories
A
D
C
All internally mounted accessories are UL Listed when field installed (except where noted) in MicroVersaTrip breakers and MagneTrip breakers with interchangeable trip units. These devices mount within the breaker envelope envelope as shown to the right.
S E R S E A K C A E D R E B T T A I L U U C S R I N I C
B
The control leads exist in pigtail form from the breaker side. These leads are terminated at secondary disconnect points for draw-out breakers or optional terminal blocks when specified for stationary breakers. All leads are color coded.
Fig. 1. Accessory location 800, 1600 and 2000-ampere envelope sizes
When ordered with draw-out circuit breaker a maximum of 48 secondary disconnects can be supplied (a maximum of 24 secondary disconnects for standard 800-ampere draw-out 1). If the combination of accessories and functions ordered per breaker require more than the maximum secondary disconnects allowed, the breaker will be wired according to standard manufacturing procedure; excess leads will be left unwired (or customer can specify that all leads be left unwired). See page 5-51 to determine the number of secondary disconnects required for each device or function.
C
5
D
B
A
Refer to table below for accessory combinations, mounting positions and lead exit information. Most accessories are available for field installation and replacement by specifying the appropriate product number. Instruction bulletins are included with each device.
Fig. 2. Accessory location. 3000 and 4000-ampere envelope sizes
All electrically operated breakers include a shunt trip or undervolt- age release for remote opening. Specify the electrical charging voltage and trip device voltage separately. The price of the electrical function will automatically automatically include the price of one shunt trip or undervoltage release (UVR); specify desired device and voltage with order. E
Fig. 3. Electrical operator location All breakers
Maximum Internal Accessories Available per Breaker Mounting Position (See Figures Above) A
Circuit Breaker Envelope Size (Amperes)
Remote Close Solenoid, Remote Charge Indicator
Shunt Trip 2
UVR
B Blown Fuse Trip
Shunt Trip
Bell Alarm
C/D
E
Auxiliary Switch
Electrical Operator
Maximum Accessories Available Per Breaker Mounting Position (See Figures Above)
800, 1600 and 2000
1
3000 and 4000
1
One of each
–
Any one
1 Any one
Accessory Lead Exit From Breaker
123
4
5
12 3
4
5,6
1 800-ampere draw-out also available with up to 48 secondary disconnects. Refer to page 5-51. 2 For 3000 and 4000 ampere envelope size breakers the shunt trip will be located in position "B" (product number TSST—L, leads out left)
unless a bell alarm is also required. 3 Deduct two auxiliary switches per shunt trip device. Deduct one auxiliary switch for all MicroVersaTrip breaker frames with a "TTR" suffix, i.e. all
MicroVersaTrip PM and MicroVersaTrip Plus with provision for trip unit control power. 4 Electrically operated breakers require the addition of a shunt trip or UVR for remote opening. 5
All leads exit left side element except auxiliary switches. The remaining switch leads exit right. Leads for first six switch elements (4 when shunt trip is used) exit left. 6 Blown fuse trip, remote close solenoid, remote charge indication—leads exit right.
Publications and Reference: See Section 21 for a list of additional product-related publications distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
www.geelectrical.com
Rev. 12/04
BuyLog Catalog
5-47 Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break I Circuit Breakers S E R S E A K C A E D R E B T T A I L U U C S R I N I C
Accessories All devices UL Listed for factory or field installation installation except where where noted.
Remote Close Solenoid with Remote Charge Indication 1 for Manual Breakers (Factory Installed Only) Circuit Breaker Envelope Size (Amperes)
Control Voltage
GO-145A
Product Number
List Price
5
800, 1600, 20 00
30 00, 400 0
$658.00
120 Vac 240 Vac
TPXCC12S TPXCC14S
$658.00
24 Vac
TPXCC08S
$658.00
120 Vac
TSXCC12S
$658.00
240 Vac
TSXCC14S
$658.00
24 Vac
TSXCC08S
$658.00
1Replacement solenoid only. only. Order product number TPXEC** or TSXEC** (add voltage suffix: 12, 14 or 08). List Price
$658.00, GO-148C. NOTE: Use of an OFF button actuated motor cut-off switch is recommended for electrically operated circuit breakers wired for remote close. Order Product Number TAPD1, List Price $520.00, GO-145A.
Remo Re mote te Ch Char arge ge In Indi dica cati tion on fo forr Man Manua uall Br Brea eake kers rs (F (Fac acto tory ry In Inst stal alle led d Onl Only) y) Circuit Breaker Envelope Size (Amperes)
GO-1 GO -145 45A A
Product Number
List Price
80 0, 160 0, 2000
TPXCAS
$488.00
3000, 40 00
TSXCAS
$488.00
Padlock On Button 2 for Manual Breakers (Factory Installed Only) Circuit Breaker Envelope Size (Amperes)
GO-145A
Product Number
80 0, 160 0, 2000
TPXPL
3000, 40 00
TSXPL
List Price
$111.00
$96.50
2 Permits padlocking of the (local) breaker ON (close) button to prevent overriding the remote close function.
Shunt Trip
GO-145A
Shunt trip provides remote control tripping of the breaker. Integral cut-off switch automati- cally de-energizes trip coil when breaker opens. It meets UL requirement for service on ground fault systems. Field Installable Product Numbers 4
Factory Installed Product Numbers
Breaker Envelope Size (Amperes) Coil Rating Vac
800, 1600 and 2000
2 500 , 3 00 0 and 4000 3
800, 1600 and 2000
3 00 0 and 4000 3
120, 240 480, 600
TPST12 TPST13
TSST12R, L TSST13R, L
TPST12S TPST13S
TSST12RS, LS TSST13RS, LS
$630.00 $630.00
12
TPST7
TSST7R, L
TPST7S
TSST7RS, LS
$630.00
24
TPST8
TSST8R, L
TPST8S
TSST8RS, LS
$630.00
48
TPST9
TSST9R, L
TPST9S
TSST9RS, LS
$630.00
125
TPST10
TSST10R, L
TPST10S
TSST10RS, LS
$630.00
250
TPST11
TSST11R, L
TPST11S
TSST11RS, LS
$630.00
List Price
Coil Rating Vdc
3 R" (right) and "L" (left) refer to accessory mounting location. When shunt trip used with blown fuse detector or UVR
specify "L". Use "R" with bell alarm. Normal lead exit is left side unless bell alarm is present. 4 To order a shunt trip for new installation on a breaker with an existing auxiliary switch contact your local GE Sales
Office for information.
distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
5-48
BuyLog Catalog
www.geelectrical.com
Rev. 12/04
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break I Circuit Breakers Accessories All devices UL Listed for factory or field installation except where where noted.
UnderVoltage Release (UVR)
S E R S E A K C A E D R E B T T A I L U U C S R I N I C
GO-145A
Automatically trips breaker when applied UVR coil voltage drops to 30-70% of rated value. Field Fie ld Inst Install allabl able e Prod Product uct Num Number bers s
Facto Fa ctory ry Ins Instal talled led Pro Produc ductt Numb Numbers ers
Breaker Envelope Size (Amperes) Coil Rating Vac
800, 1600 and 2000
3 00 0 and 4000
800, 1600 and 2000
3000 and 4000
120 240 480 600
TPUV1 TPUV2 TPUV4 TPUV6
TSUV1 TSUV2 TSUV4 TSUV6
TPUV1S TPUV2S TPUV4S TPUV6S
TSUV1S TSUV2S TSUV4S TSUV6S
$630.00
$630.00
$630.00
$630.00
TPUV7 TPUV8 TPUV9 TPUV10 TPUV11
TSUV7 TSUV8 TSUV9 TSUV10 TSUV11
TPUV7S TPUV8S TPUV9S TPUV10S TPUV11S
TSUV7S TSUV8S TSUV9S TSUV10S TSUV11S
$630.00
$630.00
5
List Price
Coil Rating Vdc 12 24 48 125 250
$630.00
$630.00
$630.00
Time Delay Module for UVR
GO-245B
The time delay module prevents nuisance tripping due to momentary loss of voltage. The module has 120 Vac input and 125 Vdc output and must be used with the 125 Vdc UVR. Description
Product Number
Time Delay Module (0.1 to 1.0 second delay)
SPUVTD
List Price
$430.00
Blown Fuse Trip (Three Coil Shunt Trip)
GO-145A
Provides single-phase protection for fuse and breaker combinations by automatically trip- ping the breaker when a fuse blows. Suitable for system voltages of 120/208 to 600 Vac. Does not protect when source single phases. Field Fie ld Inst Install allabl able e Prod Product uct Num Number bers s
Facto Fa ctory ry Ins Instal talled led Pro Produc ductt Numb Numbers ers
Breaker Envelope Size (Amperes) System Voltage
800, 1600 and 2000
3 00 0 and 4000
800, 1600 and 2000
3000 and 4000
208 to 60 0 Vac
TPST316
TSST316
TPST316S
TSST316S
Bell Alarm with Lock-out
List Price
$1530.00
GO-145A
Single-pole, double-throw (AB-type) switch element. Used for remote indication of breaker trip when caused by overload, short circuit or ground fault conditions only. Switch element ratings are identical to those listed for Auxiliary Switch Accessories. Bell alarm distinguishes between overcurrent trip and manual/shunt/UVR trip. Factory Installed Product Numbers 1 Breaker Envelope Size (Amperes) Breaker Type
800, 1600 and 2000
3 00 0 and 4000
MagneTrip Solid State
TPMBAS TPSBAS
TSBAAS TSSBAAS
1Not available for field installation except as replacement (delete S).
Publications and Reference: See Section 21 for a list of additional product-related publications
List Price
$259.00
$259.00
distributed by AA Electric Electric 1 800 237 8274 www.a aelectric.com
www.geelectrical.com
Rev. 12/04
BuyLog Catalog
5-49 Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break I Circuit Breakers S E R S E A K C A E D R E B T T A I L U U C S R I N I C
5
Accessories All devices UL Listed for factory or field installation except where noted.
Auxiliary Switch Single-pole, double-throw (AB-type) switch elements. Used for remote indication of breaker main contact position (on/closed or off/opened). Switch 600 Vac.element ratings: 1/4 ampere at 250 Vdc; 1/2 ampere at 125 Vdc; 6 amperes at 240 or Refer to page 5-47 footnote (3) for limits on maximum number in combination with other accessories.
240 Vac, 125 Vdc Field Fie ld Ins Instal tallab lable le Pro Produc ductt Numb Numbers ers
Facto Fa ctory ry Inst Install alled ed Pro Produc ductt Numb Numbers ers
Breaker Envelope Size (Amperes) No. of SPDT SPDT Switch Elements (Contacts)
800, 1600 and 2000 1
30 0 0 and 4000 2
800, 1600 and 2000
3000 and 4000
1 2 3 4 5 6 7 8
TPAS2AB1 TPAS2AB2 TPAS2AB3 TPAS2AB4 TPAS2AB5 TPAS2AB6 – –
TSAS2AB1 TSAS2AB2 TSAS2AB3 TSAS2AB4 TSAS2AB5 TSAS2AB6 – –
TPAS2AB1S TPAS2AB2S TPAS2AB3S TPAS2AB4S TPAS2AB5S TPAS2AB6S TPAS2AB7S TPAS2AB8S
TSAS2AB1S TSAS2AB2S TSAS2AB3S TSAS2AB4S TSAS2AB5S TSAS2AB6S TSAS2AB7S TSAS2AB8S
$1180.00
9 10 11 12
– – – –
– – – –
TPAS2AB9S TPAS2AB10S TPAS2AB11S3 TPAS2AB12S3
TSAS2AB9S TSAS2AB10S 3 TPAS2AB11S TPAS2AB12S3
$1215.00 $1240.00
List Price GO-145A
$251.00
$503.00
$534.00
$562.00
$623.00
$680.00
$924.00
$1300.00 $1365.00
600 Vac, Not UL Listed Field Fie ld Ins Instal tallab lable le Pro Produc ductt Numb Numbers ers
Facto Fa ctory ry Inst Install alled ed Pro Produc ductt Numb Numbers ers
Breaker Envelope Size (Amperes) No. of SPDT SPDT Switch Elements (Contacts)
800, 1600 and 2000 1
30 0 0 and 4000 1
800, 1600 and 2000
3000 and 4000
1 2 3 4 5 6 7 8 9
TPAS6AB1 TPAS6AB2 TPAS6AB3 TPAS6AB4 TPAS6AB5 TPAS6AB6 – – –
TSAS6AB1 TSAS6AB2 TSAS6AB3 TSAS6AB4 TSAS6AB5 TSAS6AB6 – – –
TPAS6AB1S TPAS6AB2S TPAS6AB3S TPAS6AB4S TPAS6AB5S TPAS6AB6S TPAS6AB7S TPAS6AB8S TPAS6AB9S
TSAS6AB1S TSAS6AB2S TSAS6AB3S TSAS6AB4S TSAS6AB5S TSAS6AB6S TSAS6AB7S TSAS6AB8S TSAS6AB9S
10 11 124
– – –
– – –
TPAS6AB10S3 TPAS6AB11S TPAS6AB12S3
List Price GO-145A
$251.00
$503.00
$534.00
$562.00
$623.00
$680.00
$924.00
$1180.00
$1215.00
TSAS6AB10S3 TPAS6AB11S TSAS6AB12S3
$1240.00 $1300.00 $1365.00
1Mounts in right pole only when shunt trip specified. 2 Field installed auxiliary switches and shunt trips must mount on opposing poles only. 3 Not available on breakers equipped with a shunt trip. 4 Not available on MicroVersaTrip PM breakers or breakers equipped with MicroVersaTrip Plus and provisions for
trip unit control power. power.
distributed by AA Electric Electric 1 800 237 8274 www.a aelectric.com
5-50
BuyLog Catalog
www.geelectrical.com
Rev. 12/04
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break I Circuit Breakers Draw-Out Breakers Accessories OEM Substructures
GO-145A
Allows a maximum of 48 secondary disconnects (except where noted); required for trip units and breaker control functions. Product Number Standard Break Frame Rating (Amperes)
Max. Am Ampere Rating
Manual
Electric
8001
80 0
TDOS08
TDOS08E
Product Number Hi-Break 1
1860000 2000 250 0 250 0 3000 4000
1860000 200 0 200 0 250 0 300 0 400 0
T 8L TD DO OS S0 16 TDOS20 TDOS25 TDOS25 TDOS30 TDOS40
T LE TD DO OS S0 18 6E TDOS20E TDOS25E TDOS25E TDOS30E TDOS40E
Number of Secondary Disconnect Circuits Required per Auxiliary Device 2
List Price
Manual
$1545.00
THDOS08
Electric
List Price
THDOS08E
$2990.00
$2990.00
$4355.00
$4715.00
$4715.00
$6300.00 $15910.00
T TH HD DO OS S0 18 6L THDOS20 THDOS25 THDOS25 THDOS30 THDOS40
T 8L TH HD DO OS S0 16 EE THDOS20E THDOS25E THDOS25E THDOS30E THDOS40E
Required Number
Neutral Sensor Leads (MicroVersaTrip only) Electrical Operation Auxiliary Switch per Element Undervoltage Release Bell Alarm Shunt Trip Blown Fuse Trip Remote Close Solenoid and Charge indication Remote Charge indication
2 6 3 2 3 2 6 3 2
Secondary Di Disconnects fo for Dr Draw-out Br Breakers Field installation kits; 48 circuits maximum per draw-out. (24 maximum for standard 800 ampere draw-out). Description
Product Number TDOS D6 D6S3 TDOSD6B
$4695.00
$5080.00
$5080.00 $6790.00 $17150.00
GO-245B
Provides positive indication that the draw-out breaker or switch primary contact fingers are fully connected to the main bus in the substructure. Switch contacts change states only after the primary fingers are fully connected when the breaker is being moved from the DISCONNECTED position through the TEST position and into the CONNECTED position.
visual position indicator on the draw-out substructure. The By-pass switch accessory does not indicate either the TEST or DISCONNECTED position. The switch assembly mounts on the stationary frame and the actuator mounts to the carriage. Switch contacts are rated at 10A at 600 Vac, 0.75A at 125 Vdc, and 0.25A at 250 Vdc. Description
List Price $320.00
$3230.00
May be used to provide control circuit continuity or downstream signaling that the draw-out breaker is connected in addition to the
GO-145A
Subst ru ruct ur ure Di sc sconnect Kit 6 Ci rc rcuit s Breaker Disconnect Kit 6 Circuits Substructure Disconnect with Zone Interlocking Z1 or Z2 Suffix Substructure Disconnect for 24V dc dc Trip Un Unit Co Control Po Power On Only Substructure Disconnect for MicroVersaTrip PM Functions and Zone Sel ec ect iv iv e Int er er lo locking (Z1 /Z /Z2 )
$3230.00
Bypass Switch
Device/Function
$1670.00
$278.00
Product Number
List Price
Bypass Switch for 800 through 4000 Amperes: 2 Elements TDOBP2L 4 Elements TDOBP4L 6 Elements TDOBP6L
$177.00
$256.00
$336.00
TDOSVD04
$144.00
Position Switch
TDOSVD02
$166.00
TDOSVD12
$166.00
Provides positive indication when the draw-out breaker or switch primary contact fingers have been fully withdrawn from the main bus connections. Switch contacts change state only after the primary fingers are fully disconnected when the breaker is being moved from
GO-245B
the CONNECTED position. position through the TEST position and into the DISCONNECTED
Draw-Out Accessories Description Mechanical In Interlock, Horizontal Interconnect Mechanical In Interlock, Vertical In Interconnect Shutters
Padlock Device Lifting Bar Racking Tool
GO-145A Frame Rating (Amperes)
Product Number
800-200 0 250 0-40 00 800-200 0 250 0-4000 800 1600-200 0 250 0-3000 4000 All All All
TDOWB1 TDOWB2 TDOWB3 TDOWB4 TDOSS08 TDOSS20 TDOSS30 TDOSS40 TDOPC TDOLB4 TDORT4
List Price
$712.00
$712.00
$712.00
$712.00
$1155.00
$1155.00
$1155.00
$1155.00
May be used as part of a safety interlocking system in addition to the visual indicator indicator on the draw-out substructure. substructure. The Position Switch accessory does not indicate either the TEST or CONNECTED position. The switch assembly mounts on the stationary frame and the actuator mounts to the carriage. Switch contacts are rated at 10A at 600 Vac, 0.75A at 125 Vdc, and 0.25A at 250 Vdc.
$46.005 $104.00 5 $70.005
Number of Switch Elements
Product Number
2 NO/2 NC 4 NO/4 NC 6 NO/6 NC
SDOPS2L SDOPS4L SDOPS6L
List Price
$177.00
$256.00
$336.00
1Allows up to 24 secondary disconnects. See table below to determine number of secondary disconnects required. 2 Breaker accessories ordered for field installation require a corresponding set of breaker mounted secondary disconnects. Refer to table above for quantity. 3 Secondary disconnects for substructure portion must be ordered and priced separately. For factory installation, so specify. 4 One lifting bar and one racking tool supplied with every five draw-out breakers at no charge. 5 GO-245B
NOTE: Breaker portion of secondary disconnects supplied at no charge when accessories are ordered with breaker. MicroVersaTrip MicroVersaTrip draw out breakers are provided as standard with secondary disconnect positions positions for possible neutral current sensor leads.
Publications and Reference: See Section 21 for a list of additional product-related publications
S E R S E A K C A E D R E B T T A I L U U C S R I N I C
5
distributed by AA Electric Electric 1 800 237 8274 www.a aelectric.com
www.geelectrical.com
Rev. 12/04
BuyLog Catalog
5-51 Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break I Circuit Breakers S E R S E A K C A E D R E B T T A I L U U C S R I N I C
Accessories All devices UL Listed for factory or field installation installation except where where noted.
Terminal Block (Factory Installed Only)
GO-145A
Offers an external means of terminating accessory leads at the breaker. A maximum of 18 terminals can be supplied on each side of the breaker (36 terminals total). For stationary breakers only. Terminal blocks are rated 10 amperes at 600 Vac. Factory Installed Product Numbers
5
Breaker Envelope Size (Amperes) Terminals
800, 1600 and 2000 1
30 0 0 and 4000
6 12 18 24 30 36
TPTB1R, L TPTB2R, L TPTB3R, L TPTB4L TPTB5L TPTB6L
TSTB1R, L TSTB2R, L TSTB3R, L – – –
List Price
$158.00
$221.00
$286.00
$444.00
$508.00
$573.00
1Left side only on frames with MicroVersaTrip MicroVersaTrip trip units.
Kirk Key Provision
GO-145A
Permits sequencing of breaker operations with other key-type devices. The key remains captured in frame except when the breaker has been locked in the OPEN position. The Kirk Key provision must be factory installed on 3000 and 4000 ampere envelope sizes. Customer to provide Kirk Key lock device(s). (Key removable when bolt extended).
800, 160 0 and 20003 30 00 and 4000
Trip Device
Maximum Number of Locks 1 2 3 4 6 6
MicroVersaTrip or MagneTrip MagneTrip4 MicroVersaTrip
Factory Installed TPK01 TPK02 TPK03 TPK04 TSK16 TSK26
List Price
$817.00
$817.00
$817.00
$817.00
$817.00
$817.00
Field Installed 2 TPK01F TPK02F TPK03F TPK04F – –
TPK01, TPK01B TPK02 TPK03 TPK04
Type F Type M2F Type M3F Type M4F
One-inch Bolt Protection
Note: Any breaker installed with Kirk Key provision must be replaced with a similarly provisioned breaker. Circuit Breaker Envelope Size (Amperes)
Zero Bolt Protection
TSK16, TSK26
List Price
$773.00
$773.00
$773.00
$773.00
Type F Type M2F Type M3F Type M4F Type M5F Type M6F
– –
2 Cannot be assembled on a breaker with padlock type TSPL or TSPDL. 3 UL Listed for factory or field installation. 4 Includes molded case switch.
Door Interlock and Padlock GO-145A Door interlock and padlock prevents opening enclosure door when breaker is closed. Available for stationary or draw-out construction. Supplied with breaker padlock suitable for use with three locks (locks supplied by purchaser). Padlock enables breaker to be locked in an open position with up to three (3) padlocks—meets California code. Padlocks supplied by purchaser. Product Number Padlock and Defeatable Door Interlock 6 Circuit Breaker Envelope Size (Amperes) 800, 1600, 20 00 30 00 00, 400 0 30 00, 400 0 30 00 00, 400 0
Padlock and Non-defeatable Door Interlock
Breaker Operation
Trip Device
Standard Break
List Price
Hi-Break
List Price
Standard Break
Manual or Electrical Manual or Electrical7 Manual Electrical7
MicroVersaTrip or Magne Trip
TSPDL8
$398.00
TSPDL8
$398.00
TSPL8,9
$106.00
TSPL8,9
$106.00
MicroVersaTrip MagneTrip MagneTrip
TPSSDIPL TPSDIPL TPSEDIPL
$398.00
THSSDIPL THSDIPL THSEDIPL
$398.00
TPSSLDA10 TPSLDA10 TPSLDEA10
$103.00
THSSLDA10 THSLDA10 THSLDEA10
$109.00
$423.00
$423.00
$398.00 $398.00
List Price
$106.00 $106.00
Hi-Break
List Price
$98.50 $114.00
6 Door interlock is defeatable with a small tool to allow authorized access. 7 OFF button actuated motor cut-off switch for electrically operated 3000 and 4000 ampere envelopes is available. Order Product Number TAPD1, List Price $520.00, GO-145A. 8
available for breakers supplied with Kirk Key provision. Factory installed only. 9 Not Padlock and non-defeatable door interlock. 10 Padlock only.
distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
5-52
BuyLog Catalog
www.geelectrical.com
Rev. 12/04
Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break I Circuit Breakers Accessories All devices UL Listed Listed for factory or field installation except where noted.
S E R S E A K C A E D R E B T T A I L U U C S R I N I C
Walking Walk ing Beam Interlock Interlock for for Stationary Stationary Breakers—No Breakers—Nott UL Listed GO-145 GO-145A A Circuit Breaker Envelope Size (Amperes)
Product Number
800, 1600, 200 0 300 0
List Price
TPWB TSWB
$525.00
$569.00
Contact GE Sales office for availability of walking beam for 4000A frame.
Adapter Kits
GO-245B
5
Premounts to bus structure allowing cabling or bussing to be completed prior to breaker mounting. Accepts either lugs or crimp type connector terminals. Product number includes adapter and hardware for three-pole line side, or three-pole load side connection connection.. Circuit Breaker Envelope Size (Amperes) 80 0 160 0
Suitable for use with up to:
Product Number
3 TPLUG108 Lugs or 3 Crimp Lugs1 pe r Pole 6 TPLUG108 Lugs or 6 Crimp Lugs1 pe r Pole 6 TPLUG108 Lugs or 6 Crimp Lugs1 pe r Pole
List Price
TPL UG UG A0 A0 8
$78.50
TPL UG UG A1 A162
20 00 00 1Anderson No. VCEL-075-12H1 or equivalent
TPL UG UG A2 A2 0
800A Power Break with TPLUGA08 adapter and 9 TPLUG108 lugs
1600A Power Break with TPLUGA16 adapter and 6 TPLUG108 lugs
Type PLUG206
Type TPLUG308
Type TPLUG408
Type TSLUG20
Typ e T P 0 8 F C A
Typ e T P 1 6 FC A
$389.00
$487.00
2 T-studs—TP16FCA T-studs—TP16FCA—included —included with adapter
Lug Kits
GO-245B
Kits accept Cu/AI wire and are suitable for direct mounting to the breaker. When order- ing Type TPLUG kits, order one kit per line or load pole. Example: A complete set of lugs for the line side of an 800A frame, 400A trip breaker would be Qty 3-TPLUG106 lugs. When ordering TSLUG kits order one kit per line or load side; TSLUG kits require use of T-studs. Example: A complete set of lugs for a 3000A frame, 2500A trip breaker would be Qty 1-TSLUG25. T-Studs would also be required. Circuit Breaker Frame Si S ize Max. Ra Rating (Amperes) (Amperes) 800 800 800 800 1600 1600 20 00 30 00 30 00 30 00 30 00 30 00 30 00 40 00
40 0 60 0 80 0 80 0 160 0 160 0 200 0 80 0 120 0 160 0 200 0 2500 300 0 400 0
Product Number
Lugs Per Ki Kit
Max. Cables Per Po Pole
Wire Range kcmil Cu Cu/AI List Pr Price
1 1 1 1 1 1 1 9 12 15 18 21 27 33
1 2 3 3 6 4 6 3 4 5 6 7 9 11
(1) #2-60 0 $18.50 (1) #2-60 0 $27.50 (3) 30 0-750 $32.00 3/0-800 $23.00 3/0-800 $23.00 500-800 $39.00 3/0-800 $23.00 3/0-800 $274.00 3/0-800 $296.00 3/0-800 $345.00 3/0-800 $383.00 3/0-800 $418.00 3/0-800 $630.00 3/0-800 $1045.00
TPLUG106 TPLUG206 TPLUG308 TPLUG1083 TPLUG1083 TPLUG408 TPLUG1083 TSLUG08 TSLUG12 TSLUG16 TSLUG20 TSLUG25 TSLUG30 TSLUG40
3 For use with adapter kit only. See table above.
T-Studs
GO-145A
Studs mount to breaker or adapter kit. All 800-3000 ampere studs studs can be rotated for either vertical or horizontal bus connection. 4000 ampere studs are vertical bus only. Product number includes one stud. Circuit Breaker Envelope Size (Amperes)
Max Rating (Amperes)
800 1600 20005 30 00 30 00 30 00 40 00 40 00
80 0 160 0 200 0 200 0 2500 300 0 400 0 400 0
Front Connected Breaker Product Number TP08FCA4 TP16FCA4 TP20FCA4 TS20FCA4 TS25FCA6 TS30FCA7 TS40FCA7 TS40LFCA7,9
Back Connected Breaker Product Number
TS20BCA4,6 TS25BCA6 7,8
4 Aluminum 5 Small envelope
2000-ampere Power Break 6 Six T-studs supplied at no charge when ordered with breaker. 7 Copper 8 Supplied with integral "T" stud 9 Extra long stud. Alternate with TS40FCA to maintain proper spacing.
Publications and Reference: See Section 21 for a list of additional product-related publications
List Price $82.00 $113.00 $113.00 $113.00 $119.00 $418.00 $562.00 $789.00
distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com
www.geelectrical.com
Rev. 12/04
BuyLog Catalog
5-53 Prices and data subject to change without notice
Insulated Case Circuit Breakers
Power Break I Circuit Breakers S E R S E A K C A E D R E B T T A I L U U C S R I N I C
5
Enclosures
General Purpose Wall and Floor Mounted Enclosures —800 and 1600 ampere enclosures are UL Listed for service entrance use for single-phase, three-wire or three-phase, four-wire, 600 Vac maximum systems. —NEMA 1 construction. —Enclosures for 800- and 1600-ampere envelope sizes are supplied with studs that support circuit breaker in correct position for easy mounting. Enclosure, circuit breaker, and neutral must be ordered separately and are shipped unassembled. —Enclosures for floor mounted 3000-ampere envelope size are shipped with circuit breaker and neutral already installed. Enclosure and circuit breaker must be ordered separately. TPB800
—Enclosure product number includes lugs. —Suitable for use on 65 kA (max) rms symmetrical systems. —Aluminum bus straps and mechanical lugs are included on floor mounted enclosures.
Power Break Enclosures Circuit Breaker Max. Envelope Size Ampere (Amp (A mper eres es)) Rati Ra ting ng
Enclosure Product Number 1 (Includes Lugs) Magn Ma gneT eTri rip p
List Price, Micr Mi croV oVer ersa saT Tri rip p 2 GO -1 -1 34 34
Field Installed Neutral Product N um um be ber
List Price, GO -1 -1 49 49
Wall Mounted 80 0 1600
80 0 160 0
$5137.00 TNT800 $384.00 $5334.00 TNT1600 $437.00
– TPB160 0
TPB800 TPB1600
TS160 0N TS20 00N TS2500N
TSS160 0N $8117.00 TSS2000N $8617.00 TSS2500N $10576.00
Floor Mounted 3,4 300 0 300 0 300 0
160 0 200 0 2500
– – –
– – –
1Add "E" suffix for motor operated breakers.
8 0 0A E n v e l o p e
2 0 0 0A E n v e l o p e
30 0 0 A E n ve l o p e
4 0 0 0A E n v e l o p e
2 For single-phase, 3-wire or 3-phase, 4-wire systems with internal ground fault
protection, appropriate neutral CT must be ordered with circuit breaker from page 5-46. 3 Enclosure may be floor or wall mounted. 4 Order by product number on standard order entry form DE-135, including any factory-installed breaker accessories. Fax order to Plainville Assembly Center at (860) 747-7032. Enclosure outline drawing is 75C325345SH1.
FAS Team Your source for factory authorized repair and modernization services for Power Break. Look to us for: —Genuine GE factory parts —Accessory installations —Direct factory replacement breakers —Test —T est certification cert ification —Rentals and loaners Repairs are performed by GE’s Factory Authorized Service Team, and 24-hour emergency service is available. For service on your Power Break breakers, contact your local sales office, or visit us at www.gepower www.gepower.com .com