Insulated Case Circuit Breakers 

Section 5: Insulated Case Circuit Breakers 

     S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

5

Power Break Insulated Case Circuit Breakers  In 1965 GE pioneered the design of insulated case circuit breakers  when it introduced the original Power Break circuit breaker. Power  Break I offered rugged system protection for heavy-duty applications  in a reliable, cost-effective insulated case. Power Break I can still be  equipped with either a dual magnetic trip for dc applications or the  latest in electronic trip protection for ac system protection and moni-  toring. When GE introduced Power Break II, the original benchmark  for performance and reliability was dramatically improved for ac  systems, while maintaining the original insulated case circuit break-  er features in a contemporary, compact physical envelope. Today, GE continues to offer both lines of breakers to cover the  range of ac and dc power system protection and control needs as  well as the continuing needs of the systems originally designed  around these capable circuit breakers.

Insulated Case Circuit Breakers

Publication References ..................... .......................................... .......................................... ............................5-2 .......5-2 Power Break‚ I and II Selection Guide............................................5-4 Power Break II

Features ................... ........................................ .......................................... .......................................... ...................................5-5 ..............5-5 Trip Unit Features .................... .......................................... ........................................... ......................................5-7 .................5-7 Trip Unit Characteristics ................... ........................................ .......................................... ............................5-8 .......5-8 Product Number Nomenclature System.......................................5-10 Interrupting Capacity and Withstand Ratings..............................5-13 How to Order....................................... Order............................................................ .......................................... ..........................5-14 .....5-14 Basic Frame Selection .................. ....................................... ........................................... ..............................5-15 ........5-15 Stationary and Draw-out Switch Selection..................................5-16 Trip Unit Selection – How to Order ................... ........................................ .............................5-17 ........5-17 Enhanced MicroVersaTrip MicroVersaTrip Rating Plug Selection ...................... .......................5-19 .5-19

Neutral Current Sensors and POWER LEADER Accessories..................... Accessories.......................................... ..................................5-21 .............5-21 Stationary and Draw-out Breaker Accessories ..................... ..........................5-22 .....5-22 Stationary Breaker Mounting Kits........................... Kits................................................ .......................5-27 ..5-27 Draw-out Breakers and a nd Accessories ..................... .......................................... .......................5-29 ..5-29 Power Break I Circuit Breakers

Ratings and Trip Characteristics ...................... ........................................... ..............................5-31 .........5-31 Draw-out Breakers .................... ......................................... .......................................... ..................................5-32 .............5-32 How to Order...................................... Order........................................................... .......................................... ...........................5-33 ......5-33 Ratings and Trip Characteristics ...................... ........................................... ..............................5-34 .........5-34 Trip Unit Features ................... ......................................... ........................................... .....................................5-36 ................5-36 Power Break I Circuit Breakers with Enhanced MicroVersaTrip MicroVersaT rip Plus and MicroVersaTrip PM Trip Units—Technical Units—Technical Data, Trip Unit Characteristics..............5-37 Power Break I Circuit Breakers with MagneTrip Unit—How to Order ..................... .......................................... ..............................5-38 .........5-38 Power Break I Circuit Breakers with Enhanced MicroVersaTrip MicroVersaT rip Plus and MicroVersaTrip PM Trip Units—Frame Selection ................... ......................................... ......................................5-40 ................5-40 Stationary Switches, Draw-out Switches ..................... .....................................5-41 ................5-41 Frame Modification Features ..................... .......................................... .....................................5-42 ................5-42 Power Break I Circuit Breakers with Enhanced MicroVersaTrip Plus and MicroVersaTrip MicroVersaT rip PM Trip Units—How to Order ..................... ..........................5-43 .....5-43 Rating Plug Selection ................... ......................................... ........................................... ..............................5-45 .........5-45 Accessories.................................... Accessories............... ........................................... ........................................... ..............................5-46 .........5-46 Enclosures ..................... .......................................... .......................................... .......................................... ...........................5-54 ......5-54

Publications and Reference:  See Section 21 for a list of additional product-related publications  distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com Rev. 12/04 

www.geelectrical.com

BuyLog Catalog

5-1  

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Insulated Case Circuit Breakers       S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

5

Associated Devices and Accessories 

UL/CSA File Numbers  Power Break Breakers ..................... ........................................... ...........................E11592/LR102 .....E11592/LR10263 63 MicroVersaTrip MicroVersaT rip Plus and MicroVersaTrip PM and Power+ Trip Units .................... .......................................... ...........................E11592/LR102 .....E11592/LR10263 63 MicroVersaT MicroVersaTrip and Power+ Rating...........................E57253/LR102 Plugs ...............E115 ...............E11592/LR10263 92/LR10263 Accessories rip ........................................ ................... ........................................... .....E57253/LR10263 63 Molded Case Switches.................................... Switches................................................E57546 ............E57546/LR16271 /LR16271

Power Break II Time Current Curve-Numbers  Functions

Enhanced MicroVersaTrip Plus™ and MicroVersaTrip PM™ Trip Units

Curve No.

Long-time Delay with Instantaneous   or Long-time Delay, Short-time Delay with Instantaneous

GES-9889

Ground Fault

GES-9890

Power Break II Circuit Breaker Accessories– Draw-Out Substructure Rail Kit ................... ........................................ .......................GEH-6440 ..GEH-6440 Walking Beam Interlock 800A, 1600A, 2000A .................... .....................GEH-6286 .GEH-6286 Walking Beam Interlock 2500-3000A...... 2500-3000A........................... ................................DEH-009 ...........DEH-009 Walking Beam Interlock 4000A .................. ........................................ .............................DEH-010 .......DEH-010 Draw Out Mechanical Interlock Inte rlock 800-2000A..........................DEH-011 Draw Out Mechanical Interlock Inte rlock 2500-4000A........................DEH-012 Neutral Kit ................... ........................................ .......................................... ........................................... ......................DEH-024 DEH-024 Hidden “ON” Button........................... Button................................................ .......................................DEH ..................DEH-025 -025 High Voltage Shunt Trip............................ Trip................................................. ..............................GEH-6519 .........GEH-6519 High Voltage Under Voltage Release ................... ...................................GEH-65 ................GEH-6520 20 Under Voltage Release Time Delay Relay ...........................GEJ-4699 ...........................GEJ-4699

Power Break II Circuit Breakers Trip Units  Power+ Tri Trip p Unit ................... ........................................ .......................................... ................................DEH-049 ...........DEH-049

Power Break II Instructions for Breakers and Accessories  Power Break II Circuit Breakers– 800-4000 A frames, 240-600 Vac..........................................GEH-62 Vac..........................................GEH-6270 70 Power Break II Circuit Breakers– Draw-Out 800-4000 Ampere Frames ................... ..................................GEH-62 ...............GEH-6271 71 Power Break II Circuit Breakers– Draw-Out Substructure .................... ......................................... ....................................GEH-62 ...............GEH-6272 72 Power Break II Circuit Breakers–Trip Unit ..................... .........................GEH-6273 ....GEH-6273 Power Break II Circuit Breaker Accessories– Auxiliary Switch Module Module..................... ........................................... .................................GEH-6274 ...........GEH-6274 Power Break II Circuit Breaker Accessories– Bell Alarm-Alarm Only.................................... Only......................................................... ......................GEH-6275 .GEH-6275 Power Break II Circuit Breaker Accessories– Door Interlock ...................... ........................................... .......................................... .............................GEH-6276 ........GEH-6276 Power Break II Circuit Breaker Accessories– Lug Kits and T Studs ..................... .......................................... ........................................GEH ...................GEH-4546 -4546 Power Break II Circuit Breaker Accessories– Bell Alarm with Lockout ................... ........................................ ....................................GEH-62 ...............GEH-6278 78 Power Break II Circuit Breaker Accessories– Key Interlock Provision .................... ......................................... ....................................GEH-62 ...............GEH-6279 79 Power Break II Circuit Breaker Accessories– Mechanical Counter ..................... .......................................... ........................................GEH ...................GEH-6280 -6280 Power Break II Circuit Breaker Accessories– Motor Operator Mechanism.......................... Mechanism............................................... ......................GEH-6281 .GEH-6281 Power Break II Circuit Breaker Accessories– Push Button Cover ..................... .......................................... .......................................... ......................GEH-6282 .GEH-6282 Power Break II Circuit Breaker Accessories– Remote Close ................... ........................................ .......................................... .................................GEH-6283 ............GEH-6283 Power Break II Circuit Breaker Accessories– Shunt Trip................... Trip........................................ .......................................... ........................................GEH ...................GEH-6284 -6284 Power Break II Circuit Breaker Accessories– Undervoltage Release ..................... ........................................... .....................................GEH-62 ...............GEH-6285 85 Power Break II Circuit Breaker Accessories– Walking-Beam Interlock ..................... .......................................... .................................GEH-6286 ............GEH-6286 TVRMS2 Test Kit.............................. Kit................................................... .......................................GEK-9 ..................GEK-97367 7367 Power Break II Circuit Breaker Accessories–

Power Break II Circuit Breakers  Rating Plugs........................... Plugs................................................ .......................................... ..............................GEH-5933 .........GEH-5933 Enclosures 800-2000A............................ 800-2000A................................................. .................................GEH-650 ............GEH-65033

Power Break II Insulated Case Switches  800-4000A, 240-600 Vac........... Vac................................ ........................................... .........................DEH-40380 ...DEH-40380 Power+ Control Units................................ Units..................................................... ............................DEH-40381 .......DEH-40381

Power Break I Time Current Curve Numbers  Functions

MicroVersaTrip Plus™ and MicroVersaTrip PM™ Trip Units

Frame

Curve No.

Long-time Delay with Instantaneous or Long-time Delay, Short-time Delay with Instantaneous

80 0A 0A -4 -40 00 00 A

G ES ES- 99 99 09 09

Ground Fault

800A-4000A

GES-9911

1 20 20 0A0A-1 1 60 60 0A 0A 2000A

G ES ES -6 -6 16 16 4 GES-6165

Long-time Delay with Instantaneous MagneTrip™ Trip Unit Long-time Delay, Short-time Delay

2500A

GES-6166

3 00 00 0A0A-4 4 00 00 0A 0A

G ES ES -6 -6 16 16 7

1 20 20 0A0A-1 1 60 60 0A 0A

G ES ES -6 -6 16 16 8

2000A

GES-6169

2500A

GES-6170

3 00 00 0A0A-4 4 00 00 0A 0A

G ES ES -6 -6 17 17 1

Draw-Out Substructure Secondary Disconnect..............GEH-6460

distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

5-2

BuyLog Catalog

www.geelectrical.com  

Rev. 12/04 

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Insulated Case Circuit Breakers  Associated Devices and Accessories 

     S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

GE Power Break I Technical Publications  For more information on these products, order publications listed in  Sections 21 and 22.

General Instructions, Breakers and Accessories  Circuit Breaker Construction Details (800-4000A) ..............GEF-4 ..............GEF-4458 458 MicroVersaTrip MicroVersaT rip Plus and MicroVersaTrip PM Trip Unit....GEH-6273 MicroVersaTrip MicroVersaT rip Plus and MicroVersaTrip PM Rating Plugs for Power Break and AKR Circuit Breakers ..........GEH-5933 MagneTrip Trip Unit (2500-3000A)........................... (2500-3000A).........................................GEH-465 ..............GEH-46588 Power Break Circuit Breaker (800-2000A) General Information, Accessory Installation ...................GEH-4693 ...................GEH-4693 Power Break Circuit Breaker (2500-4000A) General Information, Accessory Installation ...................GEH-4694 ...................GEH-4694 Power Break Draw-out Breakers (800-4000A) ...................G ...................GEH-4698 EH-4698

5

Field Installed Accessories and Options  Padlock Accessory (2500-4000A)........... (2500-4000A)................................ ...............................GEH-3394 ..........GEH-3394 Bell Alarm For MagneTrip (2500-4000A) (2500-4000A) .................... ..............................GEH-3403 ..........GEH-3403 Terminal Board For Accessories (800-4000A) ....................GEH-3407 ....................GEH-3407 Circuit Breaker Enclosure (800-4000A) .................. ................................GEH-349 ..............GEH-34988 Lug Kits (2500-4000A)...................................... (2500-4000A)........................................................... ........................GEH-4303 ...GEH-4303 Key Interlock Mounting Mount ing (800-2000A) ................... ....................................GEH-4 .................GEH-4324 324 Key Interlock Mounting Mount ing (2500-4000A) .................... ..................................GEH-434 ..............GEH-43411 Bell Alarm For MicroVersaT MicroVersaTrip rip RMS-9 (2500-4000A) ................... ........................................ .......................................... ...................................GEH-435 ..............GEH-43588 Mechanical Interlock-Stationary Breakers (800-4000A) ..................... .......................................... .......................................... ...................................GEH-438 ..............GEH-43833 Remote Close Option (2500-4000A)............... (2500-4000A).................................... ........................GEH-4544 ...GEH-4544 Lug Kits (800-2000A) (800-2000A).................. ........................................ ........................................... ........................GEH-4546 ...GEH-4546 Power Break Draw-out Secondary Disconnect (800-4000A) ..................... .......................................... .......................................... ...................................GEH-469 ..............GEH-46966 Power Break Draw-out Substructure, Accessories (800-4000A)................... (800-4000A)........................................ ...................................GEH-469 ..............GEH-46977 Power Break Draw-out Position Switch ................... ...........................DEH-40528 ........DEH-40528 Power Break “Off” Button Activated Motor Cutoff Cu toff Switch (2500-4000A)................. (2500-4000A)......................................G .....................GEH-4699 EH-4699 Power Break Draw-out Mechanical Interlock (800-4000A) ..................... .......................................... .......................................... ...................................GEH-500 ..............GEH-50066 Digital Test Kit MicroVersaTrip-Trip Units (Product Number TVRMS2) .................... ......................................... ...........................GEK-97367 ......GEK-97367 Portable Battery Pack (Product Number TVPBP)................DEJ-001 Replacement Parts  Replacement Trip Units ................... ......................................... .......................................GEH-6 .................GEH-6303 303

Publications and Reference:  See Section 21 for a list of additional product-related publications  distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com Rev. 12/04 

www.geelectrical.com

BuyLog Catalog

5-3  

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break I and II Selection Guide       S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

5

The interruption ratings and voltages shown in the table are maxi-  mum ratings. A circuit breaker of the type given in the left-hand  column may be applied at the given circuit voltage in any electrical  distribution system where the available fault current at the load  terminals of the breaker does not exceed the value in the table. That circuit breaker breaker type may also be applied at intermediate  values of circuit voltage provided the available available fault current at  the load terminals of the breaker breaker does not exceed the value in  the table for the higher higher value of voltage. voltage.

Insulated Case Circuit Breakers  Circuit Breaker Envelope Size (Amperes)

Trip Types  Power+

MicroVersaTrip Plus/PM MagneTrip

Molded Case Switch

Max IC @ 480V (kA)

Max Voltage Rating (ac)

X X X X X X

65 65 65 10 0 10 0 10 0 10 0 10 0 150 150 301 401 401 421 42 421 421

60 0 60 0 60 0 60 0 60 0 60 0 60 0 60 0 60 0 60 0 60 0 60 0 60 0 60 0 60 0 60 0

X X X X X X X

65 65 65 10 0 10 0 10 0 10 0 10 0 150 150 750 750 252 302 302 422 422 422 422

60 6 00 60 0 60 0 6 00 6 00 600 60 6 00 60 0 6 00 6 00 750 750 60 0 60 0 60 0 60 0 60 0 60 0 60 0

Max Voltage Max Frame   Rating (dc) (Amperes)  

Power Break II 80 0 1600 20 0 0 30 0 0 40 0 0 80 0 1600 20 0 0 30 0 0 40 0 0 80 0 1600 20 0 0 250 0 30 0 0 40 0 0

Standard

Hi-Break

Molded Case Switch

X X X X X X X X X X

X X X X X X X X X X

800 20 0 0 20 0 0 30 0 0 40 0 0 80 0 20 0 0 20 0 0 30 0 0 40 0 0 800 20 0 0 20 0 0 250 0 30 0 0 40 0 0

Power Break I

Standard

Hi-Break

Special Hi-Break

Molded Case Switch

       

80 0 1600 20 0 0 30 0 0 40 0 0 80 0 1600 20 0 0 30 0 0 40 0 0 30 0 0 40 0 0 80 0 1600 20 0 0 20 0 0 30 0 0 30 0 0 40 0 0

X X X X X X X X X X

X X X X X X X X X X X X

250 250 250 250 25 250 25 60 0 60 0 60 60 0 60 0 60 60 0 60 70 0 70 0

800 20 0 0 20 0 0 30 0 0 40 0 0 80 0 20 0 0 200 0 30 0 0 40 0 0 30 0 0 40 0 0 800 20 0 0 20 0 0 20 0 0 250 0 30 0 0 40 0 0

1Molded case switch ratings are short time @ 600Vac, not interrupting current. See page 5-13 for withstand ratings. 2 

Molded case switch ratings are short time @ 600Vac, not interrupting current. See page 5-34 for withstand ratings.

distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

5-4

BuyLog Catalog

www.geelectrical.com  

Rev. 12/04 

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break II Circuit Breakers  Features 

     S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

Power Break II Circuit Breakers  The Insulated Case Circuit Breaker—GE pioneered the design and  created the name in 1965. GE Power Break II insulated case circuit  breakers are the latest in reliable, flexible and easy-to-use circuit  protection. Power Break II circuit breakers are UL Listed, CSA and IEC-947-2  Certified for up to 200,000 amperes, at 240 volts rms symmetrical  interrupting capacity without fuses or current limiters. These new  insulated case circuit breakers rated 200-4000A can be applied on  ac power systems through 600 volts. All breaker frames, except  4000A stationary, are UL Listed to carry 100% of their ampere rating continuously. All frames are suitable for reverse feeding.

5

All Power Break II circuit breakers are available in two levels of  interrupting capacity—”standard break” and “Hi-Break”  breakers. Each interrupting level is available in both stationary  and draw-out construction, with a full complement of control and  signaling accessories. Standard break breakers are designed to meet the majority of  application requirements, calling for moderate levels of available short-circuit current. Hi-Break breakers are specially designed to withstand the stresses, and safely interrupt high levels of short-circuit current found in some  applications (from 65 to 200 kA rms symmetrical amperes—depend-  ing on voltage).

Greater Convenience and Operational Safety  The controls and status indicators you need most are readily  accessible. The flush-mounted handle, ON/OFF buttons, rating plug  test receptacle, bell alarm reset buttons — with or without lockout  — are easily reached and all are double-insulated from live compo-  nents. And, for added security, a standard padlock device lets you  prevent accidental or unauthorized closing of the breaker. Power Break II circuit breakers are versatile and designed for a wide variety of applications including temperature insensitive trip  units, push-to-open and close control, charge-after-close operation, 3 cycle closing, UL listed (file E 11592) field installable accessories  suitable for 50/60 Hz. All accessories and control wiring are prewired  to dedicated, secondary terminal points on each breaker.

Quick, Error-Free Installation of Universal Accessories  Drop-in bell alarm, bell alarm with manual reset lockout, shunt trip, shunt trip with lockout, and undervoltage release install in seconds. No special tools. No breaker disassembly. Just slide them into place. The modules are universal across all frame sizes and each is  mechanically keyed to its compartment so you make the right  connection, every time. These accessories are field installable  and upgrad upgradable. able.

GE’s innovative, modular, drop-in accessories provide the ultimate  customer solution for field customization: 

UL Listed  —Accessory combination (one each) shunt trip, undervoltage  release, bell alarm (alarm only), bell alarm with lockout. —Rated 12-250 Vdc through 12-240 Vac, continuous duty. Complete installation in seconds without special tools, breaker  disassembly or adjustment  —The user can select how protective trip unit functions, the shunt  trip (with or without lockout), and UVR accessories interface  with the bell alarm and bell alarm with lockout accessories: An  overcurrent, shunt trip, or UVR trip can be set to actuate the  bell alarm or bell alarm with lockout. Any combination of output  actions based on inputs can be selected. —Shunt trip and undervoltage trip targets are clearly displayed by  the trip unit LCD. Pre-wired wire harness makes field installation a snap for:  —Motor operator with remote charge indicator  —Auxiliary switches, up to 12-stage maximum  —Remote close solenoid 

Additional field-installable accessories including:  —Kirk Key locks (4 maximum)  —Limited access ON/OFF cover  —Mechanical operations counter  —Door interlock  —Walking beam interlock for stationary and draw-out breakers.

Ratings for Global Use  —Performance ratings include IEC947-2 certification.

Publications and Reference:  See Section 21 for a list of additional product-related publications  distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com Rev. 12/04 

www.geelectrical.com

BuyLog Catalog

5-5  

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

     S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

5

Power Break II Circuit Breakers 

Trip Target Module (Optional) 

Trip Unit Features 

View Button: Press the VIEW button to check the trip unit status. Reset Button: Press the RESET button to clear any target that is set.

Power+ Trip Unit Systems  The Power+ trip unit system for Power Break II insulated case  breakers consist of the trip unit, the trip actuator, current sensors  and rating plugs. The term “trip unit system” applies to the combina-  tion of these four components which form the solid-state circuit  breaker tripping system. Power+ trip units provide a complete range of standard and optional  overcurrent and ground-fault protective functions.

True RMS Sensing  The Power+ trip unit continues to  use GE’s proven technique of  measuring true rms currents of  both sinusoidal and harmonically  distorted waveforms. The frequent  sampling (48 times per cycle per  phase) allows precise calculations  of true rms current. The sampling  rate allows waveform measure-  ments up to the 11th harmonic. GE’s  true rms sensing avoids potential  underprotection or overprotection  problems associated with peak-  sensing tripping systems.

Accessory Integration  Four accessories are integrated through the Power+ trip unit. Drop-  in shunt trip (with or without lockout), bell alarms (with or without  lockout) and the undervoltage release modules fit into keyed pock-  ets. They operate through the trip units, and not through any external  mechanisms. All accessory wiring is pre-wired to secondary termi-  nals, and no user wiring is necessary. When activated, the shunt trip  (with or without lockout) and undervoltage release modules send a signal to the trip unit to energize the trip actuator and open the  breaker.

Battery check: Target modules use two standard, 3V, 16mm x 1.6mm, lithium batteries for viewing target information. Battery life depends  upon use, but may be estimated at one year. When the batteries are  energized, depressing the VIEW button will illuminate either a set  target LED, i.e., LT or the BAT LED. Once target indicators are  cleared, battery status is indicated by the BAT LED. Replacement  batteries include Panasonic CR1616, Eveready E-CR1616BP, or  Duracell DL1616B, which may be purchased commercially.

Long-time pickup: The long-time pickup indicator moves through two  transitions. As the current in any phase reaches 95% of its setpoint;  the LTPU LED begins to flash. As As current increases, flashing fre-  quency increases, until 100% of the pickup point is reached. At that  moment, the LTPU LED stays on continuously until the long-time  delay times out. Once the breaker has tripped on long-time, the OVL  target will be stored in memory. To view the trip, press the VIEW  button. To clear the target, press the RESET button. Short-time and instantaneous trips: Short-time and instantaneous  trips share the same trip target. The LTPU LED is not illuminated, since the time intervals between pickup and tripping are too short  for either function. Once the breaker has tripped on short-time or  instantaneous, the short target will be stored in memory. To view the  trip, press the VIEW button. To clear the target, press the RESET button. Ground fault trip (Target0 (Target022 only):  The trip target for a ground fault  trip is the GF LED. To To view the trip, press the view button. To To clear  the target, press press the RESET button. button. Health monitor: Trip unit health status “okay” is illustrated by slow  blinking of the LTPU LED. It may be seen by depressing and holding  the VIEW button. Sufficient power must be supplied to the trip unit  via external test kit, power pack, or current transformers for the  health monitor to be operational. Standard and Optional Protective Functions  Standard and optional protective functions are available for Power+  trip units. The breaker settings are programmed in multiples of “X”  (rating plug ampere values), “S” (current sensor ampere rating  values), and “C” (the long-time setting in amperes—multiply long-time setting by rating plug ampere rating).

Standard  —Adjustable Long-Time (L) Pickup, 0.5 - 1.0X, with four delay bands. —Adjustable Instantaneous (I) Pickup, 1.5 - 15X.1

Options  —Overload, Short Circuit, and Short-Time local trip indicators with  overload pickup warning and health monitor. —Adjustable Short-Time (S) Pickup, 1.5 - 9.0C, and delay (3 bands)  with I 2 t ON/OFF selection. —Adjustable Ground Fault (G) Pickup, 0.2 - 0.6S, and delay 1 (3 ba bands nds)) wi with th I 2 t ON/OFF selection and trip indicator. —Upgradeable Ground Fault function with use of appropriate  ground fault rating rating plug. 1Limited by breaker frame size above 2000A.

Power+ Trip Target Module 

distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

5-6

BuyLog Catalog

www.geelectrical.com  

Rev. 12/04 

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break II Circuit Breakers  Trip Unit Features 

     S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

Two Choices of Advanced, Digital Solid-State Trip Units  Enhanced MicroVersaTrip Plus and MicroVersaTrip PM trip units  give you two new ways to monitor and control the Power Break II  breaker with unprecedented ease. Through the simple keypad, the  trip unit lets you program and display a variety of functions including  tripping characteristics, remote communications, status information  and protective relaying, and allows integration with GE POWER  LEADER Power Management Systems. The trip unit display also  allows viewing of many standard metering parameters as well as  pickup alarms, trip target indications and fault status information. Enhanced MicroVersaTrip Plus and MicroVersaTrip PM trip  units continue to use GE’s proven technique of measuring true rms  currents (and voltages for MicroVersaTrip PM trip units) of both  sinusoidal and harmonically distorted waveforms. The frequent  sampling (64 times per cycle) allows precise calculations of true  rms current. The sampling rate allows waveform measurements up  to the 31st harmonic to achieve accuracies of 99%. GE’s true rms  sensing avoids potential underprotection or overprotection problems  associated with peak-sensing tripping systems.

5

Enhanced MicroVersaTrip Plus and MicroVersaTrip PM Trip  Units have been specifically designed to integrate with the  extensive capabilities offered by Power Break II circuit breakers.

The enhanced trip unit design includes a wide range of functions  and adds many new features: 

UL Listed Field-Interchangeable 

Features exclusive to MicroVersaT MicroVersaTrip rip PM Trip Units 

Non-volatile trip targets display/Cold setup capability  —Replaceable long-life batteries provide trip target indications  and cold setup capability—without the need for external power  or a battery pack.

Communications  —All information can be viewed on the LCD display or  communicated over a POWER LEADER Power  Management Managem ent System network. network.

Trip operations counter  —The number of long-time, short-time, instantaneous and ground  fault trips are individually counted and displayed.

Demand/peak demand  —The trip unit can display a rolling average of power demand  and peak power demand at user-selected intervals from 5 to  60 min minutes utes..

Trip information  —On overcurrent faults, the trip unit displays fault pickup, the type  Local and remote metering  of fault, the magnitude of the fault current and the phase the  —Amps, volts, frequency  fault occurred on. —Display indicates when a shunt trip or undervoltage release trip  has opened the breaker.

New display  —Ergonomic, 5-button keypad  —New targets with international symbols  —High-resolution LCD display for local 3-phase ammetering  —New status and setup displays for greater ease of use  —True rms sensing for accurate response to high harmonic con-  tent waveforms for Long-Tim Long-Time, e, Short-Time, and Ground Fault  protection. —50/60 Hz operation. —Interchangeable, UL Listed trip units and rating plugs with test  set jack for TVRMS2 test set. —EMI immunity per ANSI C37.90.

—Real power, total power  —Accumulated energy 

Protective relays include:  —Current and voltage unbalance  —Overvoltage  —Undervoltage  —Power reversal  —Power reversal direction setup 

Publications and Reference:  See Section 21 for a list of additional product-related publications  distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com Rev. 12/04 

www.geelectrical.com

BuyLog Catalog

5-7  

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break II Circuit Breakers       S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

5

Trip Unit Characteristics 

Power+ Trip Unit Characteristics  Long-Time

Short-Time

Frame Max. Ampere Rating 

Sensor Rating (Amperes) (S) 

800

200, 400, 800

2.4, 4.9, 9.8, 20

1600

800, 1000, 1600

2.4, 4.9, 9.8, 20

2000

2000

3000

2500, 3000

1000, 2000, 2500, 3000

2.4, 4.9, 9.8, 20

4000

4000

4000

2.4, 4.9, 9.8, 20

Envelope  Size 

2000

Current Setting (C) (Pick-Up) Multiple Multipl e of Ratin Rating g Plug Ampe Amperes res (X) (X)

Pick-up (Multiple Delay  Del ay 1 (Seconds 4 Bands)  of C Current urrent Settin Setting) g) (C) (C)

0.5, 0.6, 0.7, 0.8, 0.9, 0.95 and 1.0

2.4, 4.9, 9.8, 20

 

Delay (Sec (Seconds onds 3 Bands Bands)  )  2

1

I T in .10, .21, .35 1.5, 2.0, 2.5, 3.0, 4.0, 5.0, 7.0, and 9.0

2

2

I T out .10, .21, .35

Power+ Trip Unit Characteristics (continued)  Ground Fault  Envelope Size 

Adjustable Instantaneous Pick-Up without ST (Multiple of Rating Plug Amperes) (X) 

Adjustable Instantaneous Pick-Up with ST (Multiple of Rating Plug Amperes) (X) 

Pick-Up (Multiple of  Sensor Sens or Am Ampe pere re Ra Rati ting ng))

1.5 thru 10.0

1.5 thru 15.0

0.20 thru 0.60

1.5 thru 10.0

1.5 thru 15.0

0.20 thru 0.60

1.5 thru 10.0

1.5 thru 15.0

0.20 thru 0.60

3000

1.5 thru 10.0

1.5 thru 13.0

0.20 thru 0.37

4000

1.5 thru 9.0

1.5 thru 9.0

0.20 thru 0.30

2000

Dela De lay  y 3  (Seconds 3 Bands)  I 2T in4 .10, .21, .35

I2 T out2 .10, .21, .35

Enhanced MicroVersaTrip Plus and PM Trip Unit Characteristics  Long-Time Frame Max. Envelope Size  Ampere Rating 

Sensor Rating  (Amperes) (S) 

Current Setting (C) (Pick-Up) Mult Mu ltip iple le of of Rat Ratin ing g Plug Plug Amp Amper eres es (X) (X)

Short-Time Dela De lay  y 2  (Seconds) 

800

800

200, 400, 800

2.4, 4.9, 9.8, 20

1600

1600

800, 1000, 1600

2.4, 4.9, 9.8, 20

2000

2000

2000

2500

1000, 2000, 2500

3000

3000

4000

4000

3000 4000

2.4, 4.9, 9.8, 20

0.5 thru 1.0 in increments of 0.05

Pick-up (Multiple of Cu rr rr en en t Se tt tt in in g) g) ( C) C)

 

De la la y (S ec ec on on ds ds )   2

1

I T in 0.40 1.5 thru 9.0 in increments of 0.5

2.4, 4.9, 9.8, 20

2

2

I T out .10, .21, .35

2.4, 4.9, 9.8, 20

Trip Unit Characteristics (continued)  Adjustable Instantaneous Pick-Up with ST (Multiple of Rating Plug Amperes) (X) 

800

1.5 thru 10.0 in 0.5 increments

1.5 thru 15.0 in 0.5 increments

0.20 thru 0.60 in increments of 0.01

1600

1.5 thru 10.0 in 0.5 increments

1.5 thru 15.0 in 0.5 increments

0.20 thru 0.60 in increments of 0.01

Envelope Size 

High Range Instantaneous (Multiple of Frame Short-Time Rating) (H) 

Ground Fault 

Adjustable Instantaneous Pick-Up without ST (Multiple of Rating Plug Amperes) (X) 

Pick-Up (Multiple of Sensor Ampere Rating) 

0.20 thru 0.60 in increments of 0.01

Delay With I 2 T In Seconds 

Delay 3   With I 2 T Out Seconds  .10, .21, .35 .10, .21, .35

.44 at 200% of pick-up at lower limit of band

2000

1.5 thru 10.0 in 0.5 increments

1.5 thru 15.0 in 0.5 increments

3000

1.5 thru 10.0 in 0.5 increments

1.5 thru 13.0 in 0.5 increments

0.20 thru 0.37 in increments of 0.01

.10, .21, .35

4000

1.5 thru 9.0 in 0.5 increments

1.5 thru 9.0 in 0.5 increments

0.20 thru 0.30 in increments of 0.01

.10, .21, .35

1.0

1 Time delay shown at 600% of current setting at lower limit of band. 2 Time delay shown at lower limit of each band. All pick-up tolerances are  10%. ± 3 Time delay shown at lower limit of each band. Ground fault pick-up not to exceed 1200 amperes. 4 Time delay shown at 200% of pick-up at lower limit of band.

.10, .21, .35

X = Rating plug amps  S = Sensor amp rating  C = Long-time current setting (pick-up)  H = Short-Time Rating 

distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

5-8

BuyLog Catalog

www.geelectrical.com  

Rev. 12/04 

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break II Circuit Breakers  Trip Unit Characteristics (continued) 

Additional Features and Characteristics Exclusive to the Enhanced MicroVersaTrip PM Trip Unit 1 Trip Unit Suffix  Function Communications

Description   —POWER LE LEADER Co Communications Bu Bus Li Link

M (Metering)

P (Relaying)

PM (Metering & Relaying)  

STD

STD

STD

STD

STD

STD

Amperes (A, kA)2

Selectable Phase Current ±2.5%

Voltage (V)

L-L or L-N Volts ±1.5%

 • 

 • 

Energy (kWh, MWh, GWh)

Total Energy Usage on Brkr ±4%

 • 

 • 

Real Power (kW/MW)

L-L or L-N Power ±4%

 • 

 • 

Total Power (kVA/MVA)

L-L or L-N Power ±4%

 • 

 • 

Frequency (Hz)

Circuit Frequency ± 1Hz

 • 

 • 

 • 

 • 

Demand & Peak Demand (kW) Under Voltage Trip

—Adjustable pickup 50-90% —Adjustable delay, 1-15 seconds OFF

 • 

 • 

Over Voltage Trip

—Adjustable pickup, 110-150% —Adjustable delay, 1-15 seconds OFF

 • 

 • 

Voltage Unbalance

—Adjustable pickup, 10-50% —Adjustable delay, 1-15 seconds OFF

 • 

 • 

Current Unbalance

—Adjustable pickup, 10-50% —Adjustable delay, 1-15 seconds OFF

 • 

 • 

—Adjustable pickup, 10-990 kW —Adjustable delay, 1-15 seconds OFF —Power Reversal Direction

 • 

 • 

Power Reversal

 • 

 • 

1 MicroVers aTrip PM™ functions req uire 24 Vdc control power. 2 Ampere reading also standard on MicroVersaTrip Plus trip units.

Publications and Reference:  See Section 21 for a list of additional product-related publications  distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com Rev. 12/04 

www.geelectrical.com

BuyLog Catalog

5-9  

     S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

5

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break II Circuit Breakers       S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

Product Number Nomenclature System 

Power Break II Circuit Breaker Product Numbers 

5

1High-range instantaneous sensors only available on MicroVersaT MicroVersaTrip rip Plus and MicroVersaTrip PM units.

NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.

Accessory Product Numbers  2

2 Device Product Number requires an extender “R” for field installable kit version only.

NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.

distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

5-10

BuyLog Catalog

www.geelectrical.com  

Rev. 12/04 

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break II Circuit Breakers  Product Number Nomenclature System 

     S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

Power+ Trip Unit Product Numbers  1

5

1Device Product Number requires an extender “R” for field installable kit version only.

NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.

Power+ Rating Plug Product Numbers 

Power+ Target Module Product Numbers  TARGET00 TAR GET00 = Blank insert for Target Module  TARGET01 = Target Module without ground fault target  TARGET02 = Target Module with ground fault target  NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.

Publications and Reference:  See Section 21 for a list of additional product-related publications  distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com Rev. 12/04 

www.geelectrical.com

BuyLog Catalog

5-11  

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break II Circuit Breakers       S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

Product Number Nomenclature System 

MicroVersaTrip MicroVersaT rip Plus and MicroVersaT MicroVersaTrip rip PM Trip Unit Product Produ ct Numbers  1

5

1Device Product Number requires an extender “R” for field installable kit version only.

NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.

Rating Plug Product Numbers (MicroVersaTripPlus (MicroVersaTripPlus and PM) 

NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.

distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

5-12

BuyLog Catalog

www.geelectrical.com  

Rev. 12/04 

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break II Circuit Breakers  Interrupting Capacity and Withstand Ratings 

     S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

The interruption ratings and voltages shown in the table are maxi-  mum ratings. A circuit breaker of the type given in the left-hand  column may be applied at the given circuit voltage in any electrical  distribution system where the available fault current at the load  terminals of the breaker does not exceed the value in the table. That circuit breaker type may also be applied at intermediate values  of circuit voltage provided the available fault current at the load  terminals of the breaker does not exceed the value in the table for  the higher value of voltage.

5

Power Break II Interrupting Capacity and  Short-time Ratings–rms Symmetrical kA Frame

800A

1600 to 2000A

2500-3000A

4000A

UL 489 Ratings, 50/60 Hz Standard 240V

65

85

100

100

480V

65

65

100

100

600V

42

50

85

85

240V

100

125

200

200

480V

100

100

150

150

600V

65

65

100

100

25

40

42

42

Hi-Break

Short Time1 (0.5 sec)

IEC-947-2 Ratings 415, 50/60 Hz ICU



75

752

85

ICS



56

452

25

ICW (1 sec)



40

502

50

1 Applies to high range instantaneous or "H" option. 2 Must use 4000A construction.

Complete dimensions and weight information can be found in the  Power Break II application guide GET-8052. GET-8052.

Stationary and Draw-out Switch Withstand Ratings—rms Symmetrical kA

Switch Frame (Amperes)

Short-time  Rating, rms  Sym Amperes @ 600 Vac Max., 500 ms Max.

Max axii mu mu m Sh Sho o rt rt Ci Ci rc rc ui ui t Wi Witt hs hs tan tand d Rat Ratii ng ng When Wh en Pr Prot otec ecte ted d By By Pow Power er Br Brea eak k IIII Cir Circu cuit it Br Brea eake kers rs Breaker Frame Size (Amperes)

Standard Break PB II Circuit Breaker 240 Vac 480 Vac 600 Vac

Suii tab Su tabll e o n 20 200, 0,00 000 0 rm rms Sym Sym A mp mp er ere Fau Faull t Ci Cirr cu cu it it   When Wh en Pr Prot otec ecte ted d by Cl Clas ass s L Fu Fuse ses s As Fo Foll llow ows  s 

Hi-Break PB II Circuit Breaker 240 Vac 480 Vac 600 Vac

Line Side Max. Fuse Ampere Rating

Load Side   Max. Fuse   Ampere Rating  

80 0

30

800

65

65

50

100

10 0

65

20 00

80 0

160 0

40

1600

65

65

50

125

10 0

65

2500

160 0

200 0

40

2000

65

65

50

125

10 0

65

2500

20 00

2500

42

250 0

10 0

100

85

200

150

100

2500

2500

300 0

42

3000

10 0

100

85

200

150

100

40 00

30 00

400 0

42

4000

10 0

100

85

200

150

100

40 00

40 00

Publications and Reference:  See Section 21 for a list of additional product-related publications  distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com Rev. 12/04 

www.geelectrical.com

BuyLog Catalog

5-13  

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break II Circuit Breakers       S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

5

How To Order 

How To Order  All Power Break II circuit breakers are available in two levels of  interrupting capacity – “Standard break” and “Hi-Break” breakers. Each interrupting level is available in both stationary and draw-out  construction, are suitable for reverse feed, and have a full comple-  ment of control and signaling accessories. Power Break II circuit  breaker frames are factory configured for either the enhanced  MicroVersaTrip MicroVersaT rip Plus or MicroVersaTrip PM trip units. u nits.

1. Determine the type of frame; stationary or draw-out. 2. Determine the required breaker frame, interrupting current level, short-time rating and load requirements. Select the appropriate  frame product number and list price on page 5-15. 3. Select the basic enhanced MicroVersaTrip unit to match frame  ampere rating from page 5-17. SSF20B220 

4. Select and price the trip unit suffix from pages 5-17 and 5-18 to  match the required trip functions. Refer to page 5-8 for trip unit  characteristics. The trip unit will be installed in the frame. 5. Select and price the required rating plug from page 5-19. The  sensor ratingplugs of thewill frame must match the sensor rating of the  plug. Rating be shipped separately.

6. Internal accessories should be priced separately from pages 5-21 through 5-26. Accessories will be installed in the frame. Order  internal accessories accessories ending with “R” for field installa installation tion separately. separately. 7. Select and price externally mounted accessories, such as, push-  button cover, key interlock provisions, lug kits and T-studs from  pages 5-25 through 5-28. 8. If a draw-out breaker is required, the draw-out substructure is  priced separately from page 5-29. The draw-out breaker is shipped  including breaker, trip unit, and breaker secondary disconnects for  control and accessory wiring. The substructure secondary discon-  nects are priced separately from page 5-29.

Draw-out in Substructure 

9. Order substructure accessories, such as shutters, mechanical  interlocks, racking tool and lifting bar from page 5-30.

Pricing Example—Draw-out Breaker

Pricing Example–Stationary Breaker

1600 ampere draw-out frame, 100 kA, 480functions V IC rating, 1000 ampere  sensor, 600 ampere rating plug, trip unit including long-time  (L), short-time (S), high range instantaneous (H), factory installed  accessories including: 120 Vac electric (motor) operator; 24 Vdc  remote close solenoid; 24 Vdc shunt trip; draw-out substructure; draw-out secondary disconnect; draw-out shutter.

GO-245A

2000 ampere stationary frame, 65 kA, 480 V IC rating, 2000 ampere  sensor, 800 ampere rating plug, trip unit functions including long-time  (L), short-time (S), Instantaneous (I), MicroVersaTrip PM trip unit, field installed 120 Vac electric (motor) operator, 24 Vdc remote close  solenoid, 24 Vdc undervoltage release module. Description

Product Number

List Price  

Description

GO-245A

Product Number

List Price  

Frame

SHD16B210H

 $10182.00

Trip Unit and Suffix Adder

B210LSH

  $1350.00

Rating Plug

TR10B600

 

$89.00

Frame

SSF20B220

 $7790.00

Electric Operator

SPE120

  $1838.00 1

Trip Unit and Suffix Adder

B220LSIPM

 $2283.00

Remote Close Solenoid

SPRCS024

 

$315.00 1

Rating Plug

TR20B800

 

Shunt Trip

SPST024

 

$328.00 1

Electric Op Operator-field in installed

SPE120R

  $1671.00 1

Drawout Substructure

SPHDOS16

  $1403.00 1

SPRC SP RCS0 S024 24R R

  $286.00 1

Sub Su b str stru u ctu cturr e Se Sec c on on dar dary y Di Di sc sc on on nec nectt

SPD SP D OSD OSD36 36S S

 

$283.00 1

S PUV PUV0 0 24 24 DC DC R

  $301.00 1

Substructure Shutter Kit

SPDSS20

 

$501.00 1

Remo Re mote te Cl Clos ose e So Sole leno noidid-fi fiel eld d ins insta talle lled d Unde Un derv rvol oltt age age R ele elea a se se -f -f ie ie ld ld ins instt all alle ed

$89.00

1 GO-245B 

distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

5-14

BuyLog Catalog

www.geelectrical.com  

Rev. 12/04 

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break II Circuit Breakers Frame 

     S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

5

Basic Frame Selection—Stationary Circuit Breaker Envelope Size (Amperes) 

800

1600

2000

Circuit Breaker Frame Size (Amperes) 

800

1600

2000

GO-245A Standard Break

Current Sensor (Amperes)  200

SSF08*202,H

  $6006.00

 

SHF08*202,H

  $6500.00

400

SSF08*204,H

  $6006.00

 

SHF08*204,H

  $6500.00

800

SSF08*208,H

  $6006.00

 

SHF08*208,H

  $6500.00

800

SSF16*208,H

  $7342.00

 

SHF16*208,H

  $8165.00

1 00 00 0

S SF SF 16 16* 21 21 0, 0, H

  $7342.00

 

SHF16*210,H

  $8165.00

1 60 60 0

S SF SF 16 16* 21 21 6, 6, H

  $7342.00

 

SHF16*216,H

  $8165.00

2000

SSF20*220,H

  $7790.00

 

SHF20*220,H

  $9124.00

SSF25*210,H

  $8569.00

 

SHF25*210,H

$10035.00

SSB25*210,H

  $8569.00

 

SHB25*210,H

$10035.00

SSF25*220,H

  $8569.00

 

SHF25*220,H

$10035.00

SSB25*220,H

  $8569.00

 

SHB25*220,H

$10035.00

SSF25*325,H

$15107.00

 

SHF25*325,H

$18930.00

SSB25*325,H

$15107.00

 

SHB25*325,H

$18930.00

SSF30*330,H

$19229.00

 

SHF30*330,H

$24101.00

SSB30*330,H

$19229.00

 

SHB30*330,H

$24101.00

 

SHF40*440 3

$38691.00

1000

2500

2000

3000 2500

3000 4000

4000

Hi-Break  

Product 1 Number 

3000 4000

 

SSF40*440

3

Product 1 Number 

List Price  2 

$31714.00

Basic Frame Selection—Draw-out (without substructure) Circuit Breaker

Circuit Breaker

Envelope Size (Amperes) 

Frame Size (Amperes) 

800

1600

2000

GO-245A

Standard Break

Hi-Break  

Current Sensor (Amperes) 

Product 1 Product  1 Number

200

SSD08*202,H

  $7085.00

 

SHD08*202,H

  $7597.00

400

SSD08*204,H

  $7085.00

 

SHD08*204,H

  $7597.00

800

SSD08*208,H

  $7085.00

 

SHD08*208,H

  $7597.00

800

SSD16*208,H

  $9205.00

 

SHD16*208,H

$10182.00

10 00 00

SS D1 D16 *2 *2 10 10 ,H ,H

  $9205.00

 

SHD16*210,H

$10182.00

16 00 00

SS D1 D16 *2 *2 16 16 ,H ,H

  $9205.00

 

SHD16*216,H

$10182.00

2000

SSD20*220,H

  $9604.00

 

SHD20*220,H

$11118.00

10 00 00

SS D2 D25 *2 *2 10 10 ,H ,H

$10563.00

 

SHD25*210,H

$12229.00

20 00 00

SS D2 D25 *2 *2 20 20 ,H ,H

$10563.00

 

SHD25*220,H

$12229.00

25 00 00

SS D2 D25 *3 *3 25 25 ,H ,H

$18234.00

 

SHD25*325,H

$22431.00

3000

3000

SSD30*330,H

$22819.00

 

SHD30*330,H

$28125.00

4000

4000

SSD40*440,H

$38007.00

 

SHD40*440,H

$46116.00

800

1600

2000

2500 3000

4000

List Price  2 

List Price  2 

Product 1 Product  1 Number

List Price 2   

1

Add 'H' suffix to product number for high-range instantaneous protection. Price adder is on trip unit only. High-range instantaneous feature available only with MicroVersaTrip Plus™ or MicroVersaTrip PM™.

2

Prices shown include basic "Power+ LI" trip unit but do not include rating plug.

3 80%

rated. *Replace * with B for MicroVersa Trip Plus or PM trip unit: or D for Power+™ trip unit.

Publications and Reference:  See Section 21 for a list of additional product-related publications  distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com Rev. 12/04 

www.geelectrical.com

BuyLog Catalog

5-15  

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break II Circuit Breakers       S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

5

Stationary and Draw-out Switch Selection  How To Order  How to Order 

Power Break II Rating Plug Selection

1. Choose a frame from the Molded Case Switch Frame tables below  2. Select a Control Unit from the Control Unit table below. The sensor  rating of the control unit should match the sensor rating of the  switch. Choose a control unit with suffix T2 to get ground fault target indication.

Basic Control Unit

Current Rating (Amperes)

 

D208

3. Select a rating plug from the table to the right. 4. Select all other accessories just as for any Power Break II Circuit  Breaker.

D210

Molded Case Switch Frames—Stationary

D216

GO-245D  

Switch En Envelope Size Si ze (A (Am m pe pe re re s) s)

Switch Fr Frame Size Si ze (A (Am m pe pe re re s) s)

Current Se Sensor Rati Ra ting ng (A (Am m pe pe re re s) s)

Product   Num Nu m be be r

80 0 160 0 20 0 0

80 0 160 0 20 0 0

80 0 160 0 20 0 0

SSF08Y208 SSF16Y216 SSF20Y220 SSF25Y325 SSB25Y325 SSF30Y330 SSB30Y330

250 0 3000

 

250 0

 

30 0 0

 

30 0 0

L ist ist Pr Pric ice e   

$3119.00

   

$4099.00 $4609.00

 

$7334.00

 

$7334.00

 

$12411.00

 

$10204.00

Molded Case Switch Frames—Draw-out 1 

GO-245D 

Switch En Envelope Size (Amperes)

Switch Fr Frame Size (Amperes)

Current Se Sensor Rating (Amperes)

Product   Number

80 0 160 0 20 0 0

80 0 160 0 20 0 0 250 0 30 0 0 40 0 0

80 0 160 0 20 0 0 250 0 30 0 0 40 0 0

SSD08Y208 SSD16Y216 SSD20Y220 SSD25Y325 SSD30Y330 SSD40Y440

3000 40 0 0

 

D220

D325

D330

List Price    

$4061.00

 

$5913.00

 

D440

 

$6426.00

 

$10204.00

 

$15864.00

 

$25526.00

40 0 450 50 0 50 60 0 70 0 80 0 60 0 80 0 10 0 0 80 0 10 0 0 110 0 120 0 160 0 10 0 0 120 0 150 0 160 0 20 0 0 160 0 20 0 0 250 0 20 0 0 250 0 30 0 0 160 0 20 0 0 250 0 30 0 0 360 0 40 0 0

GO-245A

Powe Po werr + Stand Standar ard d Rating Plug List Price $89.0 0

Powe Po werr + Groun Ground d Faul Fault  t  Rating Plug   List Price $747.00  

TR8C40 0 TR8C450 TR8C50 0 TR8C60 0 TR8C70 0 TR8C80 0 TR10C60 0 TR10C80 0 TR10C10 0 0 TR16C80 0 TR16C10 0 0 TR16C110 0 TR16C120 0 TR16C160 0 TR20C10 0 0 TR20C120 0 TR20C150 0 TR20C160 0 TR20C20 0 0 TR25C160 0 TR25C20 0 0 TR25C250 0 TR30C20 0 0 TR30C250 0 TR30C30 0 0 TR40C160 0 TR40C20 0 0 TR40C250 0 TR40C30 0 0 TR40C360 0 TR40C40 0 0

TR8C40 0GF TR8C450GF TR8C50 0GF TR8C60 0GF TR8C70 0GF TR8C80 0GF TR10C60 0GF TR10C80 0GF TR10C10 0 0GF TR16C80 0GF TR16C10 0 0GF TR16C110 0GF TR16C120 0GF TR16C160 0GF TR20C10 0 0GF TR20C120 0GF TR20C150 0GF TR20C160 0GF TR20C20 0 0GF TR25C160 0GF TR25C20 0 0GF TR25C250 0GF TR30C20 0 0GF TR30C250 0GF TR30C30 0 0GF TR40C160 0GF TR40C20 0 0GF TR40C250 0GF TR40C30 0 0GF TR40C360 0GF TR40C40 0 0GF

1Use only with Hi-Break draw-out substructure.

Ordering Example  Control Units  Switch Envelope Size (Amperes)

Switch Frame Size (Amperes)

Sensor (Amperes)

80 0

80 0

80 0

160 0

 

160 0

1000 1600

20 0 0

20 0 0

20 0 0 1000

250 0 3000

 

20 0 0 2500

40 0 0

30 0 0

30 0 0

40 0 0

40 0 0

Product Number      

           

D208 D208T2 D210 D210T2 D216 D216T2 D220 D220T2 D210 D210T2 D220 D220T2 D325 D325T2 D330 D330T2 D440 D440T2

List Price Adder, GO-245A  

$0.00

 

$160.00

 

$0.00

 

$160.00

 

$0.00

   

$160.00 $0.00

 

$160.00

 

$0.00

 

$160.00

 

$0.00

 

$160.00

 

$0.00

 

$160.00

 

$0.00

 

$160.00

 

$0.00

 

$160.00

1600 ampere drawout switch; field installed 120 Vac electric (motor)  operator; 24 Vdc remote close solenoid; 24 Vdc shunt trip; drawout  substructure; drawout secondary disconnect; drawout shutter. Description

Product Number

Frame Control Unit Rating Plug Electric Operator

SSD16Y216 D216 TR16C160 0 SPE120

Remote Close Solenoid Shunt Trip Drawout Substructure Substr Sub struct ucture ure Se Secon condar dary y Disc Disconn onnect ect Substructure Shutter Kit

SPRCS024 SPST024 SPHDOS16 SPDOSD SPD OSD36S 36S SPDSS20

List Price   $5913.001

 

$0.002

   

$89.002 $1838.003

 

3

 

 

$315.00 $328.003 $1403.003

     

$283.003 $501.003

1GO-245D  2GO-245A 3GO-245B 

distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

5-16

BuyLog Catalog

www.geelectrical.com  

Rev. 12/04 

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break II Circuit Breakers  Trip Unit Selection  How To Order 

Example: 

How to Order  1. Determine the basic trip unit product number.

1600 Ampere frame, 1000 ampere sensor, Long-time (L). Short-time  (S), Instantaneous (I), MicroVersaTrip PM with metering only. Order B210LSIM ( List List price adder: $1,733.00, GO-245A) . The replace-  ment trip unit product number would be B210LSIMR.

2. Determine the type of trip unit, Power+, MicroVersaTrip MicroVersaTrip Plus or  MicroVersaTrip MicroVersaT rip PM trip unit.

3. Select the trip unit suffix representing the protection function to 

5

complete trip unit product number.

4. Determine list price adder to breaker frame list price on page 5-15. 5. Order rating plug separately. Pricing does not include rating  plug plu g pri price. ce.

6. For replacement trip units, add suffix “R”. Check Elitenet for List  Price and GO schedule.

Power Break II Trip Unit Suffix  Power+ Trip Unit Suffix Selection  Trip Unit Suffix 1

List Price  Adder, GO-245A

LI

 

Basic Trip Unit Selection 

Trip Indicators  L/ST/l 1

Adjustable Instantaneous 

 

No Price Adder

GF 2 

—  

Long-Time (L) 

Short-Time (ST) 

 • 

 



 • 



 • 

 



 • 

 

LIT1

 

$140.00

 

• 

LIT2

 

$160.00

 





• 

 

$683.00





 • 

 • 

 • 



 • 

 • 

 • 

 • 

• 

 • 

 • 

LSI

 

LSIT1

 

$823.00

   • 

LSIT2

 

$843.00

 • 

 

Frame Size  (Amperes) 

Frame Rating  (Amperes) 

800

800

Inst. (l) 





 • 

Sensor  (Amperes) 

Power+™ Trip Units 

Enhanced MicroVersaTrip  Plus™ and MicroVersaTrip  PM™ Trip Units 

200

D202

B202

400

D204

B204

800

D208

B208

800

D208

B208

1000

D210

B210

1600

D216

B216

2000

D220

B220

1000

D210

B210

2000

D220

B220

1600 1600-2000

2000

1

For high-range instantaneous or zone selective interlocking select MicroVersaTrip Plus or PM trip units. 2 For ground fault-protection, select appropriate rating plug.

2500 2500-3000

4000

2500

D325

B325

3000

3000

D330

B330

4000

4000

D440

B440

MicroVersaTrip MicroVersaT rip Plus with Selectable Phase Ammeter—Trip Indicators Standard  Trip Unit  Suffix 3 

List Price  Adder, GO-245A 3 

Trip Indicators 

Selectable Phase Ammeter 

Long-Time  (L) 

Short-Time  (ST) 

Inst. (I) 

High Inst. (H) 

Ground Fault (G) 4 

GF Zone Interlock (Z1) 5 

GF/ST Zone Interlock (Z2) 5 

Adjustable Instantaneous  LI LIG

 

$300.00





• 

$958.00

 •



• 

 

$1250.00

 •



• 

$983.00

 •



• 

 • 

 • 

 

$1640.00

 •



• 

 • 

 • 

 • 

 

LIGZ1 LSI LSIG

 

 

 •   

 • 

• 

 •



LSIGZ1

 

$1933.00

 •



• 

 • 

 • 

 •

LSIGZ2

 

$2225.00

 • 

 •

• 

 • 

 • 

 •

$1350.00

 • 

 • 

 • 

 • 

 • 

• 

•  • 

Fixed High Range Instantaneous 6  LSH

 

$2008.00

 • 

 • 

 • 

 • 

 • 

 • 

LSHGZ1

 

$2300.00

 • 

 • 

 • 

 • 

 • 

 •

LSHGZ2

 

$2593.00

 • 

 • 

 • 

 • 

 • 

 •

LSHG

 

•  • 

3

Add suffix to basic trip unit product number. Make List Price Addition for trip unit suffix.. For single-phase 3 wire or 3-phase, 4-wire applications, order appropriate neutral current sensor and price separately, page 5-20. Defeatable Ground Fault (not UL Listed) is available. Use code GD in place of G. Add List Price $250.00, GO-245A, to the price of the trip unit. 5 Requires purchase of Zone Selective Interlock module(s) Type TIM1 (120 Vac control voltage). List Price $402.00, GO-245B. 6 Not available on 4000A stationary breaker frame. 4

Publications and Reference:  See Section 21 for a list of additional product-related publications  distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com Rev. 12/04 

www.geelectrical.com

     S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

BuyLog Catalog

5-17  

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break II Circuit Breakers       S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

Trip Unit Selection (continued) 

MicroVersaTrip MicroVersaT rip PM with Metering and Communications—T Communications—Trip rip Indicators Standard  Trip Unit Suffix 1

List Price Adder, GO-245A1

Trip Indicators 

Selectable Phase Ammeter 

Long-Time (L) 

Short-Time (ST) 

Inst. (I) 

High Inst. (H) 

Ground Fault (G) 2 

GF Zone Interlock (Z1) 3 

GF/ST Zone Interlock (Z2) 3 

Adjustable Instantaneous   

LIM

$1050.00  

LIGM

 

LIGZ1M

5

 

LSIM

 

 

• 

 • 

 • 

 • 

$1708.00

 • 

 • 

 • 

 • 

 • 

$2000.00

 • 

 • 

 • 

 • 

 • 

$1733.00

 • 

 • 

 •

• 

 • 

$2390.00

 • 

 • 

 • 

 • 

 • 

 • 

LSIGZ1M

 

$2683.00

 • 

 • 

 • 

 • 

 • 

 • 

LSIGZ2M

 

$2975.00

 • 

 • 

 • 

 • 

 •

• 

LSIGM

 • 

 •   • 

Fixed High Range Instantaneous 4   

LSHM

 

LSHGM

$2100.00

 • 

 • 

 • 

 • 

 • 

$2758.00

 • 

 • 

 • 

 • 

 • 

 • 

LSHGZ1M

 

$3050.00

 • 

 • 

 • 

 • 

 • 

 •

LSHGZ2M

 

$3343.00

 • 

 • 

 • 

 • 

 • 

 •

•  • 

MicroVersaTrip MicroVersaT rip PM with Protective Relays and Communications—T Communications—Trip rip Indicators Standard  Trip Unit Suffix 1

List Price Adder, GO-245A 1

Long-Time (L) 

Short-Time (ST) 

Inst. (I) 

High Inst. (H) 

Ground Fault (G) 2 

Trip Indicators 

Selectable Phase Ammeter 

• 

 • 

 • 

 • 

$1508.00 $1800.00

 • 

 • 

 • 

 • 

 • 

 • 

 • 

 • 

 • 

 • 

$1533.00

 • 

 • 

 • 

 • 

 • 

$2190.00

 • 

 • 

 • 

 • 

 • 

 • 

 • 

 • 

 • 

 • 

 • 

 • 

 • 

GF Zone Interlock (Z1) 3 

GF/ST Zone Interlock (Z2) 3 

Adjustable Instantaneous  LIP

 

LIGP

$850.00    

LIGZ1P LSIP

   

LSIGP

 

LSIGZ1P

 

$2483.00

 • 

LSIGZ2P

 

$2775.00

 • 

 • 

 • 

 • 

$1900.00

 • 

 • 

 • 

 • 

 • 

 • 

 •   • 

Fixed High Range Instantaneous 4  LSHP

 

$2558.00

 • 

 • 

 • 

 • 

 • 

 • 

LSHGZ1P

   

$2850.00

 • 

 • 

 • 

 • 

 • 

 • 

LSHGZ2P

 

$3143.00

 • 

 • 

 • 

 • 

 • 

 • 

LSHGP

 •   • 

MicroVersaTrip MicroVersaT rip PM with Metering, Protective Relays and Communications—T Communications—Trip rip Indicators Standard  Trip Unit Suffix 1

List Price Adder, GO-245A 1

Trip Indicators 

Selectable Phase Ammeter 

Long-Time (L) 

Short-Time (ST) 

Inst. (I) 

High Inst. (H) 

Ground Fault (G) 2 

GF Zone Interlock (Z1) 3 

GF/ST Zone Interlock (Z2) 3 

Adjustable Instantaneous  LIPM

 

LIGPM

$1600.00    

LIGZ1PM LSIPM LSIGPM

   

• 

 • 

 • 

 • 

$2288.00

 

 • 

 • 

 • 

 • 

 • 

$2550.00

 • 

 • 

 • 

 • 

 • 

$2283.00

 • 

 • 

 • 

 • 

 • 

$2940.00

 • 

 • 

 • 

 • 

 • 

 • 

LSIGZ1PM

 

$3233.00

 • 

 • 

 • 

 • 

 • 

 • 

LSIGZ2PM

 

$3525.00

 • 

 • 

 • 

 • 

 • 

 • 

$2650.00

 • 

 • 

 • 

 • 

 • 

$3308.00

 • 

 • 

 • 

 • 

 • 

 • 

$3600.00

 • 

 • 

 • 

 • 

 • 

 • 

$3893.00

 • 

 • 

 • 

 • 

 • 

 • 

 • 

 •   • 

Fixed High Range Instantaneous 4  LSHPM LSHGPM LSHGZ1PM LSHGZ2PM

       

 •   • 

1

Add suffix to basic trip unit product number. Make List Price Addition for trip unit suffix.. For single-phase 3 wire or 3-phase, 4-wire applications, order appropriate neutral current sensor and price separately, page 5-20. Defeatable Ground Fault (not UL Listed) is available. Use code GD in place of G. Add List price $250.00, GO-245A, to GO-245A, to the price of the trip unit. 3 Requires purchase of Zone Selective Interlock module(s) Type TIM1 (120 Vac control voltage). List Price $402.00, GO-245B. 4 Not available on 4000A stationary breaker frame. 2

distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

5-18

BuyLog Catalog

www.geelectrical.com  

Rev. 12/04 

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break II Circuit Breakers  Enhanced MicroVersaTrip, Rating Plug Selection 

Power Break II Rating Plug Selection

Power+ Trip Unit Standard FS raizm ee S Rean tisnogr CRuartrienngt (Amperes) (Amperes) (Amperes)  20 0

800 400

80 0-1600

80 0

1000

1600

  1600

200 0

 

 

20 00

1000

2500

200 0

2500

300 0

30 00

400 0

400 0

 

100 150 200 150 200 225 250 300 400 300 400 450 500 600 700 800 400 600 800

Ra Ltisint gPrPiclueg ,s $89.00

GO-245A Power+ Trip U ni nit Gr Ground Fault Rating LisPtluPgrisce, $747.0 0

Enhanced  MicroVersaTrip Plus  and Enhanc ed  MicroVer sa saTrip PM PM   Trip Unit   Ra Ltisint gPrPiclueg, s   $89.0 0  

TR2C100 TR2C150 TR2C20 0 – TR4C20 0 TR4C225 TR4C250 TR4C30 0 TR4C40 0 – TR8C40 0 TR8C450 TR8C50 0 TR8C60 0 TR8C70 0 TR8C80 0 – TR10C600 TR10C800

TR2C10 0GF TR2C150GF TR2C200GF – TR4C200GF TR4C225GF TR4C250GF TR4C300GF TR4C400GF – TR8C400GF TR8C450GF TR8C500GF TR8C600GF TR8C700GF TR8C800GF – TR10C600GF TR10C800GF

TR2B100 TR2B150 TR2B200 TR48150 TR48200 TR48225 TR48250 TR48300 TR48400 TR8B300 TR8B400 TR8B450 TR8B500 TR8B600 TR8B700 TR8B800 TR10B400 TR10B600 TR10B800

10 00 00 600 800 10 00 00 110 0 120 0 160 0 750 800 10 00 00 1200 150 0 160 0 20 00 00 400 600 800 10 00 00 750 800 10 00 00 1200

TR10C10 00 00 – TR16C80 0 TR16C10 00 00 TR 16 16C 110 0 TR16C120 0 TR16C160 0 – – TR20C10 00 00 TR20C1200 TR20C150 0 TR20C160 0 TR20C20 00 00 – TR10C600 TR10C800 TR10C10 00 00 – – TR10C10 00 00 TR10C120 0

TR10C10 00 00GF – TR16C800GF TR16C10 00 00GF TR16 C1 C110 0G 0GF TR16C120 0G 0GF TR16C160 0G 0GF – – TR20C10 00 00GF TR20C120 0GF TR20C150 0G 0GF TR20C160 0G 0GF TR20C20 00 00GF – TR20C60 0GF TR20C80 0GF TR20C10 00 00GF – – TR10C10 00 00GF TR10C1200GF

TR10B10 00 00 TR16B60 0 TR16B80 0 TR16B10 00 00 TR 16 16B 110 0 TR16B120 0 TR16B160 0 TR20B750 TR20B800 TR20B10 00 00 TR20B1200 TR20B150 0 TR20B160 0 TR20B20 00 00 TR10B400 TR10B600 TR10B800 TR10B10 00 00 TR20B750 TR20B800 TR20B10 00 00 TR20B1200

150 0 160 0 20 00 00 160 0 2000 250 0 1200 1600 200 0 250 0 30 00 00 160 0 20 00 00 250 0 30 00 00 360 0 40 00 00

TR10C150 0 TR10C160 0 TR10C20 00 00 TR25C160 0 TR25C200 0 TR25C250 0 – – TR30C200 0 TR30C250 0 TR30C30 00 00 TR40C160 0 TR40C20 00 00 TR40C250 0 TR40C30 00 00 TR40C360 0 TR40C40 00 00

TR10C150 0G 0GF TR10C160 0G 0GF TR10C20 00 00GF TR25C160 0G 0GF TR25C20 00 00GF TR25C250 0G 0GF – – TR30C3000GF TR30C250 0G 0GF TR30C30 00 00GF TR40C160 0G 0GF TR40C20 00 00GF TR40C250 0G 0GF TR40C30 00 00GF TR40C360 0G 0GF TR40C40 00 00GF

TR20B150 0 TR20B160 0 TR20B20 00 00 TR25B160 0 TR25B20 00 00 TR25B250 0 TR30B1200 TR30B1600 TR30B20 00 TR30B250 0 TR30B30 00 00 TR40B160 0 TR40B20 00 00 TR40B250 0 TR40B30 00 00 TR40B360 0 TR40B40 00 00

Power+ Target Module

GO-245A

Power+ trip units are designed to accept an optional field-installable  target module. The target module indicates long-time pickup, battery  status, trip unit health status, and whether a breaker trip was  caused by an overload, a short circuit or a ground fault. Target  modules are available with or without ground fault indication. Trip Indicator L/ST/1 Ground Fault – –  • –  • •

Product   Number TARGET00 TARGET0 TA RGET01 1 TARGET02 TARG ET02

Power+ Trip Target Module 

for a list of additional product-related publications  distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

www.geelectrical.com

   

MicroVersaTrip and MicroVersaTrip PM Rating Plug 

Publications and Reference:  See Section 21

Rev. 12/04 

 

BuyLog Catalog

5-19  

List Price   $60.00 $140.00 $160.00

     S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

5

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break II Circuit Breakers       S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

Neutral Current Sensors and POWER LEADER Accessories 

Neutral Current Sensors 1  Breaker Frame (Amperes)

Neutra Neut rall Se Se nso nsor  r  Rating or Tap Settings (A (Amperes)

200 400 400 800 1000 1000 1600 1600 200 0 1000 1000 1000 1000 200 0 250 0 300 0 400 0

200 400/200 600/30 02 800/400 800/40 02 10 00/50 0 120 0/60 02 1600/100 0 2000/10 00 800/40 02 10 00/50 0 120 0/60 02 160 0/10002 2000/1200 2500/1800 30 00/2400 40 00/3000

800

5

800-1600 1600

GO-245B 

C irc ircui uitt Bre Brea a ke ke r Sensor Rating (Amperes)

 

2000

3000

4000

Product   Number

List Pr Price  

  TSVG302 TSVG304A   TSVG306A   TSVG308A   TSVG808A   TSVG810A   TSVG812A   TSVG816A   TSVG820A   TSVG808A   TSVG810A   TSVG812A   TSVG816A   TSVG820A   TSVG825A   TSVG830A   TSVG940A  

$266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00

1Match neutral current sensor rating (or tap setting) to circuit breaker sensor rating. 2 For use with multiple source ground fault protection schemes. Rating does not match 

MicroVersaTrip MicroVersaT rip Plus or PM frame sensor.

MicroVersaTrip Portable Test Kit

Product Number

Portable Test Kit

TVRMS2

 

Power supply for furnishing 24Vdc control power for MicroVersaTrip  Plus and PM trip units. Two versions are available: a 1.5 ampere  version with AC and DC input voltages and a 0.8 ampere version  capable of operating from 120/230Vac. Both power supplies have  inherent transient protection circuits. Description

System Requirements (price separately)

1.5 ampere power supply Price one PLPS4G01 for each eac h lin line-up e-up.. 45 trip uni units ts and 100 ft. maxi maximum mum..

Input Inp ut pow power er,, 100V 100VA A (85-265Vac (85-265V ac or 100100-370V 370Vdc) dc)

GO-245B  

Product Number

List Price  

PLPS4G0 PLP S4G01 1   $1250.00

Reference  Instructions

GEH-6492

POWER LEADER Voltage Conditioner

G0-104A

Conditions and scales 120Vac to 1.76 Vac for use by the trip unit for  voltage sensing. Provides transient protection. Voltage conditioners  require isolation PTs PTs.. Description

System Re R equirements (price separately)

Supplies isolated bus voltage vol tage sig signal nal to MicroVersaTrip PM trip tr ip un unit its. s.

One set of 3 vol voltage tage con conditi ditioner oners s required for each voltage sensing loca lo cati tion on.. PT PTs s al also so re requ quir ired ed..

Rating Plug Removal Tool

List Price    

$75.00

TRTOOL

Product   Number

List Price  

  $200.00 PLVC VC1G 1G01 01   per set

GO-135S  

Product Number TVPBP

Product   Number

$3000.00

The handheld MicroVersaTrip portable battery pack provides an  independent power source for Enhanced MicroVersaTrip Plus and  MicroVersaTrip PM trip units as an alternative to the TVRMS2 test  set. The power pack is used to power up the trip unit to set or adjust  trip set points when the breaker is on the bench or otherwise not  powered up. It connects to the trip unit through the rating plug test   jack. It requires three (3) ( 3) standard 9 Vdc alkaline batteries bat teries (not  included). Product number TVPBP List Price, $75.00, GO-245A. MicroVersaTrip Plus and PM Portable Power Pack

G0-104A

List Price  

MicroVersaTrip Portable Power Pack

Description

POWER LEADER Power Supplies

GO-245B  

The test kit product number TVRMS2 is a portable, battery-powered, test kit which provides for trip unit health checks and functional trip  and no-trip tests. It also provides defeat of the ground-fault function  and can be used in conjunction with high-current test equipment. The test kit can be used to provide +24V power to the trip unit for  cold set-up and viewing of trip targets. This test kit is for use with  RMS-9, Epic, MicroVersaTrip Plus and MicroVersaTrip MicroVersaTrip PM trip units. The kit uses six rechargeable ni-cad or standard alkaline "D" cells  supplied by the customer. Kit can also be powered by 120 Vac source. Description

Neutral Current Sensor 

List Price  

 

$12.00

distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

5-20

BuyLog Catalog

www.geelectrical.com  

Rev. 12/04 

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break II Circuit Breakers  Stationary and Draw-out Breaker Accessories  All devices UL Listed Listed for factory or field installation except where noted.

     S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

Accessories—Stationary and Draw-out Breakers  The complete line of Power Break II breaker accessories may be either factory or field  installed to meet user needs. The electronic shunt trip, the bell alarm, the bell alarm with  mechanical lockout, and the undervoltage release modules are drop-in from the front of the  breaker, interchangeable across all frames, and require no field internal wiring or breaker  disassembly. Auxiliary switch modules are available in groups of 4, 8 or 12, NO/NC single-  pole, double-throw (SPDT) switches. Their installation simply involves removal of breaker  cover, installation of the switch module, routing of wiring and installation of the pre-wired  terminal block and re-installation of the cover. Auxiliary switches are also interchangeable  across all Power Break II breaker frames.

Electrical Operator

GO-245B

5

 

The electrical operator mounts inside the front cover of the manually operated breaker. This  accessory can be added to any Power Break II breaker in the factory or the field to provide  electrical spring charging and charge indication. For remote closing, the remote close sole-  noid must be priced and ordered separately. All breakers are prewired to dedicated second-  ary terminals for easy field installation. When electrical operation is used, either a shunt trip  or an undervoltage release must be ordered and priced separately. Ratings Vac

Ratings Vdc

Field Installable Product Number

Factory Installed   Product Number

List Price

List Price  

120



SPE120R

 

$1671.00

 

SPE120

 

$1838.00

240



SPE240R

 

$1869.00

 

SPE240

 

$2056.00



24

SPE024R

 

$1869.00

 

SPE024

 

$2056.00



48

SPE048R

 

$1869.00

 

SPE048

 

$2056.00



72

SPE072R

 

$1869.00

 

SPE072

 

$2056.00



125

SPE125R

 

$1869.00

 

SPE125

 

$2056.00

Remote Close Solenoid

Electrical Operator 

GO-245B  

This accessory provides an electrically operated solenoid which, when energized, closes  the breaker. It is suitable for control interlock schemes in which manual closing capability  would not be convenient or desirable. The breaker is provided with a manual close button, which can be replaced by the Hidden "ON" Button accessory and/or sealed using the Limited  Access Pushbutton Cover accessory. The remote close accessory is continuously rated and  has an anti-pump feature, which prevents a motor operated breaker from repeatedly closing  into a fault. Closing control voltage must be removed and re-applied for each breaker  closure. Ratings Vac

Ratings Vdc

Field Installable Product Number

Factory Installed   Product Number

List Price

List Price  

120



SPRCS120R

 

$286.00

 

SPRCS120

 

$315.00

240



SPRCS240R

 

$286.00

 

SPRCS240

 

$315.00



24

SPRCS024R

 

$286.00

 

SPRCS024

 

$315.00



48

SPRCS048R

 

$286.00

 

SPRCS048

 

$315.00



72

SPRCS072R

 

$286.00

 

SPRCS072

 

$315.00



125

SPRCS125R

 

$286.00

 

SPRCS125

 

$315.00

Remote Close Solenoid 

Publications and Reference:  See Section 21 for a list of additional product-related publications  distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com Rev. 12/04 

www.geelectrical.com

BuyLog Catalog

5-21  

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break II Circuit Breakers       S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

5

Stationary and Draw-out Breaker Accessories  All devices UL Listed for factory or field installation except where noted.

Shunt Trip

GO-245B

 

The shunt trip accessory is an electronic module, which provides remote control capability  to open the circuit breaker. When activated, the shunt trip module sends a signal to the trip  unit to open the breaker. This allows the trip unit to record, display, distinguish and  communicate (in MicroVersaTrip PM trip units) that the opening event was initiated by the  shunt trip device. The shunt trip is continuously rated and requires no cut-off switch. When  energized, the shunt trip supplies +24Vdc power to the trip unit to power the display. Ratings Vac

Ratings Vdc

Field Installable Product Number

Factory Installed   Product Number



12

SPST012R

 

$301.00

 

SPST012

 

$328.00

24

24

SPST024R

 

$301.00

 

SPST024

 

$328.00

List Price

List Price  

48

48

SPST048R

 

$301.00

 

SPST048

 

$328.00

120

125

SPST120R

 

$301.00

 

SPST120

 

$328.00

208



SPST208R

 

$301.00

 

SPST208

 

$328.00

240

250

SPST240R

 

$301.00

 

SPST240

 

$328.00

480



SPST480R1

$301.00

 

SPST4801

$328.00

60 0



SPST60 0R1

$301.00

 

SPST6001

$328.00

Shunt Trip Module 

1Kit contains externally mounted transformer.

Shunt Trip with Lockout Module GO-245B   The shunt trip with lockout is identical to the regular shunt trip, but when energized, it will  also prevent closure of an "open" breaker by mechanically blocking both manual and electri-  cal closing. When energized, the closing springs will not discharge, the movable contacts  will not move; the contacts are "kiss free."  Ratings Vac

Ratings Vdc

Field Installable Product Number

Factory Installed   Product Number

List Price

List Price  

12

SPSTL012R

 

$401.00

 

SPSTL012

 

$428.00

24

24

SPSTL024R

 

$401.00

 

SPSTL024

 

$428.00

48

48

SPSTL048R

 

$401.00

 

SPSTL048

 

$428.00

120

125

SPSTL120R

 

$401.00

 

SPSTL120

 

$428.00

208



SPSTL208R

 

$401.00

 

SPSTL208

 

$428.00

240

250

SPSTL240R

 

$401.00

 

SPSTL240

 

$428.00

480



SPSTL480R1

$401.00

 

SPSTL480

 

$428.00

60 0



SPSTL60 0R1

$401.00

 

SPSTL600

 

$428.00

1Kit contains externally mounted transformer.

distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

5-22

BuyLog Catalog

www.geelectrical.com  

Rev. 12/04 

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break II Circuit Breakers  Stationary and Draw-out Breaker Accessories  All devices UL Listed for factory or field installation except where where noted.

Undervoltage Release Module

     S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

GO-245B  

The undervoltage release is an electronic module used to open the circuit breaker when the  monitored voltage drops below 35-60% of its rated value, and prevents the breaker from  being closed until the monitored voltage exceeds 80% of its rated value. An undervoltage release trip operation is produced by the MicroVersaTrip Plus unit in  response to a signal from the undervoltage release module. This allows the trip unit to  record, display, distinguish and communicate (in MicroVersaTrip PM trip units) that the  breaker opening event was due to undervoltage release. Operation of the undervoltage  release module will prevent breaker contact closure, i.e. "kiss-free" operation. When ener-  gized, the undervoltage release supplies +24 Vdc power to the trip unit to power the display. Ratings Vac

Ratings Vdc

Field Installable Product Number

24 48 120 208 240 480 60 0 – –

– – – – – – – 24 48

SPUVO24ACR SPUVO48ACR SPUV120ACR SPUV208ACR SPUV240ACR SPUV480ACR1 SPUV60 0ACR1 SPUVO24DCR SPUV048DCR

– –

125 250

SPUV125DCR SPUV250DCR

Factory Installed   Product Number

List Price  

$301.00

 

$301.00 $301.00

 

$301.00

                 

   

$301.00 $301.00

   

 

$301.00

 

$301.00

 

$301.00

 

$301.00 $301.00

5

List Price  

SPUV024AC SPUV048AC SPUV120AC SPUV208AC SPUV240AC SPUV480AC1 SPUV600AC1 SPUV024DC SPUV048DC

 

$328.00

 

$328.00

 

$328.00

 

$328.00

 

$328.00

SPUV125DC SPUV250DC

Undervoltage Release Module 

$328.00  

$328.00 $328.00

 

$328.00

   

$328.00 $328.00

1Kit contains externally mounted transformer.

Time Delay Module for UVR

GO-245B  

The time delay module prevents nuisance tripping due to momentary loss of voltage. The module has 120 Vac input and 125 Vdc output and must be used with the 125 Vdc UVR. Description

Product Number

Time Delay Module (0.1 to 1.0 second delay)

SPUVTD

List Price  

 

$430.00

Bell Alarm (Alarm Only)

GO-245B  

The bell alarm module is used to signal breaker "tripped" status to other accessories (e.g., external alarm devices, indicating lights, relays, or logic circuits) for remote indication and  interlocking functions. The bell alarm response is configurable by means of rear-mounted  DIP switches on the trip unit. The bell alarm can be made to operate in response to an over-  current (including ground fault) or protective relay trip and/or a shunt trip operation, and/or  operation of the undervoltage release module. It is not actuated as a result of normal  breaker "ON/OFF" operation. This module provides a visual, mechanical pop-out target, which protrudes through the face  of the circuit breaker door when it operates. The bell alarm may be reset manually by  depressing the mechanical target, or automatically by closing the breaker. The bell alarm is provided with one SPDT switch with control power duty contacts as shown  in the auxiliary switch accessories. Ratings Vac

Ratings Vdc

Field Installable Product Number

240 60 0

125-250 125-250

SPBAA240R SPBAA600R1

Factory Installed   Product Number

List Price  

$124.00 $124.00

   

SPBAA240 SPBAA600

Bell (Alarm Only) 

List Price    

$135.00

 

$135.00

1600 Vac module not UL Listed.

Reference:  See Section 21 Publications and Reference: See for a list of additional product-related publications  distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com Rev. 12/04 

www.geelectrical.com

BuyLog Catalog

5-23  

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break II Circuit Breakers       S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

5

Stationary and Draw-out Breaker Accessories  All devices UL Listed for factory or field installation except where noted.

Bell Alarm With Lockout

GO-245B  

The bell alarm with lockout module combines both the bell alarm and a manual lockout func-  tion. The bell alarm switch operates identically to the standard bell alarm module, except  that the mechanical pop-out target must be manually reset before the breaker can be closed. Operation of the bell alarm with lockout module can be independently set by means of set-  ting the DIP switches at the rear of the trip unit. Current rating of the single SPDT switch is  identical to the auxiliary switch accessories. Ratings Vac 240 60 0

Ratings Vdc 125-250 125-250

Field Installable Product Number  

SPBAL240R SPBAL600R1

Factory Installed   Product Number

List Price $124.00 $124.00

   

SPBAL240 SPBAL600

List Price    

$135.00

 

$135.00

1600 Vac module not UL Listed.

Bell Alarm with Mechanical Reset Lockout 

Auxiliary Switch  An auxiliary switch signals the circuit breaker’s primary contact position (i.e., OPEN or  CLOSED) to other devices, such as indicating lights, relays or logic circuits. This enables the  user to provide remote indication, interlocking or control operations as a function of breaker  primary contact position. The auxiliary switch operation is independent of the method by  which the breaker is opened or closed. The auxiliary switch does not distinguish between a "tripped" or "open" condition. The auxiliary switch contacts follow the main breaker contacts  on opening and precede them on closing. Auxiliary switch modules are available with 4, 8 or 12 NO/NC (SPDT) switches for control  power duty ac/dc ratings. When ordered for field installation, an auxiliary switch module  comes pre-wired to its own terminal board, which mounts with one screw to the left of the  breaker. A special accessory, available for draw out breakers, comes pre-wired to the  breaker secondary disconnect. All switch ratings are 6A at 120V-600 Vac, 1/2A at 125 Vdc  and 1/4A at 250 Vdc. Auxiliary Switch with Pre-wired  Secondary Term Terminals inals for Stationary Breaker 

Auxiliary Switches for Stationary Breakers Ratings Vac

Ratings Vdc

No. of SPDT  SPDT  Switch Elements (Contacts)

240 240 240 60 0 60 0

125-250 125-250 125-250 125-250 125-250

4 8 12 4 8

Field Installable Product Number SPAS240AB4R SPAS240AB8R SPAS240AB12R SPAS60 0AB4R1 SPAS60 0AB8R1

GO-245B   Factory Installed   Product Number

List Price  

$268.00

 

$564.00  

$651.00 $268.00 $564.00

         

List Price    

SPAS240AB4 SPAS240AB8 SPAS240AB12 SPAS600AB41 SPAS600AB81

$293.00

 

$616.00  

$710.00 $293.00 $616.00

1600 Vac module not UL Listed.

Auxiliary Switches for Draw-out Breakers Ratings Vac

Ratings Vdc

No. of SPDT  SPDT  Switch Elements (Contacts)

240 240 240 60 0 60 0

125-250 125-250 125-250 125-250 125-250

4 8 12 4 8

1600 Vac module not UL Listed.

GO-245B  

Field Installable Product Number SPAS240AB4DR SPAS240AB8DR SPAS240AB12DR SPAS60 0AB4DR1 SPAS60 0AB8DR1

Factory Installed   Product Number

List Price    

$551.00 $847.00  

$934.00 $551.00 $847.00

         

SPAS240AB4D   SPAS240AB8D   SPAS240AB12D   SPAS600AB4D1 SPAS600AB8D1

List Price   $576.00 $899.00 $993.00 $576.00 $899.00

Auxiliary Switch with Pre-wired  Secondary Term Terminals inals for Draw-out Draw-out Breaker 

distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

5 24

BuyLog Catalog

www.geelectrical.com  

Rev. 12/04 

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break II Circuit Breakers  Stationary and Draw-out Breaker Accessories  All devices UL Listed for factory or field installation installation except where noted.

Mechanical Operations Counter

     S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

GO-245B  

The mechanical operations counter is mounted behind the front cover of the breaker. It is  viewable through a rectangular knockout window opening in the breaker cover. It is a five-digit, non-resettable counter, which is actuated each time the breaker is opened by  any mean means. s. Field Installed Product Number  

SPCOUNTERR

$100.00

5

Factory Installed   Product Number

List Price  

List Price    

SPCOUNTER

$125.00

Mechanical Operations Counter 

Limited Access Pushbutton Cover

GO-245B  

This accessory limits access to "ON/OFF" control of a breaker to authorized personnel. The  pushbutton cover accessory consists of transparent hinged covers that can be individually  sealed to the limited access assembly. Both the "ON" and "OFF" buttons can be pilot drilled to  allow use of a 1/8" rod to operate either one or both pushbuttons. Field Installed Product Number

Factory Installed   Product Number

List Price  

SPPBCOVERR

$80.00

 

List Price    

SPPBCOVER

$90.00

Breaker with limited access pushbutton  cover assembly installed 

Hidden "ON" Button

GO-245B

 

The hidden "ON" button is assembled to the mechanism behind an unlabeled, false  pushbutton. Manual closing of the breaker can only be performed by means of a small  diameter personnel.rod. This accessory is used to limit access to the manual "ON" control to authorized  Field Installed Product Number SPPBNONR

Factory Installed   Product Number

List Price  

$64.00

 

List Price    

SPPBNON

$64.00

Activating the breaker closing mechanism  through the hole in the Hidden “ON” Button 

Replacement Trip Unit Access Doors

GO-148G  

Description

Product Number

Micr Mi croV oVer ersa saT Tri rip p Pl Plus us an and d PMTri rip p Un Unit its s Power Plus Trip Units

100 0054 5433 335P 5P1 1 10 054335P2

List Price    

$20.00

 

$16.00

Publications and Reference:  See Section 21 for a list of additional product-related publications  distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

www.geelectrical.com

Rev. 12/04 

BuyLog Catalog

5 25   Prices and data subject to change without notice 

 

Insulated Case Circuit Breakers 

Power Break II Circuit Breakers       S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

5

Stationary and Draw-out Breaker Accessories  All devices UL Listed for factory or field installation installation except where where noted.

Key Interlock Provisions  The key interlock provision enables the user to mount a one- to four-cylinder, narrow-faced, Kirk-type FN or Superior customer-supplied lock on the face of the breaker. This accessory  provides mounting for key interlocks that are furnished by the customer. The key interlock  provision works in conjunction with the padlock provision. The key interlock extends a lever  through the padlock hasp when the key is turned to the key removal or bolt extended posi-  tion. Additionally, the accessory provides a hasp for mounting three padlocks with 1/4" to 3/8"  diameter shanks.

Key Interlock Reference Table  Product Number

Number of Locks

Kirk Key Lock Product Number

SPK4 SPK4 SPK4 SPK4

1 2 3 4

KFN00 0011 KFN000 021 KFN000 031 KFN000 041

Superior   Product Number   S105827Y  S105828Y  S105829Y  S105827-4Y 

Key Interlock Kit (lock not included) 

1Final digit may be 0, 1, 2 or 3 depending on number of key removal positions.

Product Numbers, Key Interlock Provisions

GO-245B  

Circuit Breaker Envelope Size (Amps)

Number of Key Locks

Field Installed Product Number

All

1 to 4

SPK4R

Factory Installed   Product Number

List Price  

$355.00

 

SPK4

Door Interlock

 

List Price   $426.00

GO-245B

 

The door interlock provides interlocking of the circuit breaker compartment’s hinged door so  that the breaker must be in the "OFF" position before the door can be opened. The door inter-  lock is defeatable with a small tool to allow authorized access. Field Installed Product Number SPDILR

Factory Installed   Product Number

List Price  

$173.00

 

List Price    

SPDIL

$208.00

Padlock Provisions (Standard)  Padlocking provisions are standard on all Power Break II circuit breakers. When the breaker  is in the open position, and the padlock hasp is raised at least 1/4", the breaker cannot be  closed mechanically or electrically. The hasp accepts up to three padlocks with 1/4" to 3/8"  diameter shanks.

Walking Beam Interlocks—Stationary Breakers Only

Door Interlock 

GO-245B  

Walking beam interlocks are mechanical devices used to prevent two adjacent circuit break-  ers from both being in the "ON" or closed position at the same time. However, both breakers  can be in the "OFF" or open position. Circuit Breaker  Envelope Size (Amperes)

Product Number

800, 160 0 and 20 00 300 0 400 0

SPWB20 SPWB30 SPWB40

List Price    

$1228.00

 

$1228.00

 

$1228.00

distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

5 26

BuyLog Catalog

www.geelectrical.com  

Rev. 12/04 

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break II Circuit Breakers  Stationary Breaker Mounting Kits  All devices UL Listed Listed for factory or field installation except where noted.

Lug Adapter Kits

GO-245B

     S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

 

Kits pre-mount to bus structure allowing cabling or bussing to be completed prior to breaker  mounting. Accepts either lugs or crimp-type connector terminals. Kit includes adapter and  hardware for either a three-pole line-side, or a three-pole load-side connection. (Lugs not  included). Frame Rating (Amperes)

Product Number

800

TPLUGA08

1600

TPLUGA162

2000

SPLUGA203

5

Suitable for   use with up to: 3 TPLUG108 Lugs or 3 crimp Lugs1 per pole 6 TPLUG108 lugs or 6 crimp Lugs1 per pole 6 TPLUG108 Lugs or 6 crimp Lugs1 per pole

List Price    

2000 Ampere Power Break II breaker with SPLUGA20 lug adapter kit and 18 lugs  (TPLUG108) 

$78.50

 

$389.00

 

$487.00

1Anderson No. VCEL-075-12H1 or equivalent  2 T-Studs - TP16FCA - included with adapter  3 T-Studs - SP20FCA - included with adapter 

Type TPLUG206 

Lug Kits

GO-245B

 

Kits accept Cu/AI wire and are suitable for direct mounting to the breaker. When ordering  Type TPLUG kits, order one kit per line or load pole. Example: A complete set of lugs for the  line side of an 800A frame, 400A trip breaker would be Qty 3-TPLUG106 lugs. When ordering TSLUG kits order one kit per line or load side; TSLUG kits require use of T-studs. Example: A complete set of lugs for a 3000A frame, 2500A trip breaker would be Qty 1-TSLUG25. T-Studs would also be required. Circuit Breaker Max Rating Envelope Size (Amperes) (Amperes)

800

1600

2000

300 0 400 0

 

 

Product Number

Lug Per Kit

Max. Ca Cables Per Pole

400 600 800 800 800 1600

TPLUG106 TPLUG206 TPLUG308 TPLUG1084 TPLUG1084 TPLUG408

1 1 1 1 1 1

1 2 3 3 6 4

2000 800 1200 1600 2000 2500 3000 4000

TPLUG1084 TSLUG08 TSLUG12 TSLUG16 TSLUG20 TSLUG25 TSLUG30 TSLUG40

1 9 12 15 18 21 27 27

6 3 4 5 6 7 9 9

Wire Range   kcmil Cu/AI

List Price  

(2) #2 2-600   (2) #2 2-600   (3) 300-750   3/0-80 0     3/0-80 0   500-80 0 3/0-80 0 3/0-80 0 3/0-80 0 3/0-80 0 3/0-80 0 3/0-80 0 3/0-80 0 3/0-80 0

4 For use with adapter kit only. See table above.

   

$18.50 $27.50 $32.00 $23.00 $23.00 $39.00 $23.00 $274.00 $296.00

 

$345.00

 

$383.00

 

$418.00

   

 

Type TPLUG408 

$630.00 $1045.00

Type TPLUG308 

Type TSLUG20 

Publications and Reference:  See Section 21 for a list of additional product-related publications  distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

www.geelectrical.com

Rev. 12/04 

BuyLog Catalog

5-27   Prices and data subject to change without notice 

 

Insulated Case Circuit Breakers 

Power Break II Circuit Breakers       S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     I      R      N      I      C

5

Stationary Breaker Mounting Kits, Wall Mounted Enclosures, Floor Mounted Enclosures  All devices UL Listed for factory or field installation except where noted. T-Studs  T-studs mount directly to the breaker, and can be rotated for either vertical or horizontal bus  connection. 4000 ampere T-studs are for vertical bus bars only. Product number includes one  stud. Both copper and aluminum T-studs are tin-plated.

T-Studs—Front Connected Breaker Circuit Breaker Frame Size (Amperes)

GO-245B  

Max. Ra Rating   (Amperes)

800 800 2000 2000 2500 2500 3000 4000 4000

800 800 800-2000 800-2000 2000 2500 3000 4000 4000

Product Number

List Price  

SP08FCA1

$36.00

SP08FCC2 SP20FCA1 SP20FCC2 SPS20FCA1 SPS25FCC2 SPS30FCC2 SPS40FCC2 SPS40LFCC2,3

$36.00 $49.00 $49.00 $48.75 $51.50 $181.50 $395.00

T-Studs—Back Connected Breaker Circuit Breaker Frame Size (Amperes)

GO-245B  

Max. Ra Rating   (Amperes)

2500 2500 3000

2000A Breaker with "T" Studs Mounted 

$240.50

Product Number

List Price  

SPS20BCA1,4 SPS25BCC2,4

2000 2500 3000

 

$48.75 $51.50

2,5

$181.50

1Aluminum  2 Copper  3 Extra long stud. Alternate with SPS40FCC for ease of installation. 4 Six T-studs at no charge when ordered with breaker  5 Supplied with integral T-stud 

Stationary Breakers General Purpose, Wall Mounted Enclosures  General purpose, NEMA 1 enclosures are available for Power Break II breakers with  neutrals for 800, 1600 and 2000 amperes. These units are UL Listed for service entrance  use for single-phase three-wire, three-phase three-wire, or three-phase four-wire power  systems through 600 Vac. Enclosures are provided with breaker mounting studs and lugs. Enclosures, breakers and neutrals are ordered and shipped separately, unassembled. These units are suitable for use in 65 kA (max.) rms symmetrical symmetrical systems. Floor mounted enclosures are available. For Ordering and Pricing, see Engineered Products  Catalog, Section 3: Individually Mounted Circuit Breakers.

Wall Enclosure and Field Installed Neutral  Circuit Breaker Envelope Size (Amperes)

Current Sensor Rating (Amperes)

Enclosure 7  Product Number (include Lugs)

800 1600 2000

20 0-800 100 0-1600 20 00

SPB08W SPB16W SPB20W

Field installed  Neutral Product Number

List Price GO-134C  

$2569.00

 

$3667.00

 

$4309.00

     

TNT800 TNT1600 TNT2000

List Price   GO-149  

 

$384.00  

$437.00

 

$537.00

7 For single-phase, 3-wire or 3-phase, 4-wire systems with internal ground fault protection, appropriate neutral CT must 

be ordered with circuit breaker from page 5-20.

Trimplate

GO-245B

Factory Installed Product Number

Field Installable   Product Number

SPTRIMPLATE

SPTRIMPLATER

List Price  

   

$64.00

distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

5-28

BuyLog Catalog

www.geelectrical.com  

Rev. 12/04 

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break II Circuit Breakers  Draw-out Breakers and Accessories 

     S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

Features  —Draw-outs through 4000 ampere —Draw-outs amperess are UL Listed, 100% rated  —Modular design for simplified installation—6 basic sizes—800, 1600, 2000, 2500, 3000, 4000 —5 inch pole centers  centers  —Screw racking mechanism provides positive racking motion  —Self aligning primary and secondary disconnects  —Four position draw-out—engaged, test, disengaged, fully withdrawn—  simplifies system testing and inspection  —Breaker position indicator clearly shows breaker position  —Provisions for padlocking breaker in test or disengaged position  —Mechanical interlock logic prevents movement of a closed breaker  —Suitable for reverse feeding 

5

Draw-out Breaker in Substructure 

Description  The draw-out assembly consists of a substructure housing unit designed as a compact self-  supporting unit and a draw-out breaker which must be ordered separately. The substructure  contains mounting holes, self-supporting male plugs and extendable rails, and can be  ordered separately for installation in your switchboard or enclosure. The Power Break II draw-out breaker is a self-contained, heavy-duty assembly designed to  offer simplified breaker inspection without de-energizing the main bus structure. The draw-out breaker comes complete with racking mechanism drive, wheels, primary and  secondary disconnects and cooperating interlock systems. Accessories such as dead-front shutters, by-pass switches (position switches), and padlock  devices are available and field installable.

OEM Substructures

GO-245B

Substructures are available Substructures available for both both standard and Hi-Break Hi-Break Power Break Break II breakers. breakers. Holes  are provided for bolting on a shelf or supports. Holes are also provided in the primary stabs  for bolting to busbars or terminal lugs. Substructure secondary disconnects are ordered and  priced separately. Order Hi-Break substructures for use with Power Break II switches. Frame Rating (Amperes)

Standard Break Product Number

Hi-Break   Product Number

List Price  

List Price  

80 0

SPSDOS08

$671.00

 

SPHDOS08

160 0

SPSDO S16

 

$1300.00

 

SPHDOS16

 

$1403.00

20 0 0

SPSDOS20

$1892.00 $2048.00

SPHDOS20

SPSDOS25

   

 

250 0

 

SPHDOS25

   

$2040.00 $2207.00

30 0 0

SPSDOS30

 

$2739.00

 

SPHDOS30

 

$2951.00

40 0 0

SPSDOS40

 

$6916.00

 

SPHDOS40

 

$7455.00

Secondary Disconnect for Draw-out Breakers

 

$724.00

GO-245B  

Control wiring is connected through draw-out secondary disconnects in the "TEST" and  "CONNECTED" positions only. Up to 72 control circuits are possible through 36 position plug-style secondary disconnect blocks factory mounted to each side of draw-out breakers. One substructure disconnect (SPDOSD36S) must be ordered for each breaker when acces-  sories or communications are used. When auxiliary switches are used along with any other  electrical accessory or communications, two disconnects must be ordered. Location

Product Number

List Price

Substructure

SPDO SD36S

 

$283.00

Breaker1

SPDOSD36B

 

$283.00

1Order for replacement only. Included and factory wired with draw-out breaker.

Publications and Reference:  See Section 21 for a list of additional product-related publications  distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

 

 

1600-ampere substructure for standard break breaker 

Rev. 12/04 

www.geelectrical.com

BuyLog Catalog

5-29   Prices and data subject to change without notice 

 

Insulated Case Circuit Breakers 

Power Break II Circuit Breakers       S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

5

Draw-out Breakers and Accessories  All devices UL Listed for factory or field installation except where noted.

Shutter Kit

GO-245B

This field installable kit provides shutters used to prevent uninten-  tional contact with potentially live primary disconnect stabs when a breaker is racked out of an energized switchboard compartment. Frame Rating

Product Number

80 0-20 0 0A

SPDSS20

 

List Price   $501.00

30 0 0A

SPDSS30

 

$501.00

40 0 0A

SPDSS40

 

$501.00

By-Pass Switch

  Racking Tool

GO-245B

The racking tool is a drive wrench with a square 1/2" socket that  engages the racking mechanism of the draw-out breaker. One rack-  ing tool is supplied with every five draw-out breakers at no charge. Frame Rating

Product Number

All

TDO RT

List Price    

$70.00

GO-245B   Mechanical Interlocks

Provides positive indication that the draw-out breaker or switch  primary contact fingers are fully connected to the main bus in the  substructure. Switch contacts change states only after the primary  fingers are fully connected when the breaker is being moved from  the DISCONNECTED position through the TEST position and into the  CONNECTED position. May be used to provide control circuit continuity or downstream  signaling that the draw-out breaker is connected in addition to the  visual position indicator on the draw-out substructure. The By-pass  switch accessory does not indicate either the TEST or DISCON-  NECTED position. The switch assembly mounts on the stationary  frame and the actuator mounts to the carriage. Switch contacts are  rated at 10A at 600 Vac, 0.75A at 125 Vdc, and 0.25A at 250 Vdc. Number of  Switch Elements

Product Number

2 NO /2 N C

TDO BP2L

 

$177.00

4 NO /4 N C

TDO BP4L

 

$256.00

6 NO /6 N C

TDO BP6L

 

$336.00

List Price  

Racking Padlock Provision

GO-245B  

The racking padlock provides a means for the user to prevent racking  tool engagement, thereby preventing movement of the breaker  between the DISCONNECTED, TEST and CONNECTED positions. Frame Rating

Product Number

All

TDOPC

List Price    

$46.00

 

GO-245B  

Mechanical interlocks provide the same function as the walking  beam accessory for stationary breakers, except they are used with  two draw-out breakers: mounted on common compartment center-  line, in either the same vertical section or adjacent vertical sections. Envelope Size

Product Number

80 0-20 0 0

SPDOWB20

 

List Price   $1310.00

250 0-40 0 0

SPDOWB40

 

$1310.00

Rail Kit

GO-245B

 

This field installable rail kit may be used to shorten the two standard  OEM substructure rails by 3-1/2 inches. Product Number SPRAILS

List Price  

 

$310.00

Position Switch

GO-245B  

Provides positive indication when the draw-out breaker or switch  primary contact fingers have been fully withdrawn from the main bus  connections. Switch contacts change state only after the primary  fingers are fully disconnected when the breaker is being moved from  the CONNECTED position through the TEST position and into the  DISCONNECTED position.

May be used as part of a safety interlocking system in addition to  the visual indicator on the draw-out substructure. The Position  Lifting Bar GO-245B   Switch accessory does not indicate either the TEST or CONNECTED  The lifting bar provides a means of safely lifting a draw-out circuit  position. The switch assembly mounts on the stationary frame and  breaker. A chain hook can be attached to the central hole in the lift-  the actuator mounts to the carriage. Switch contacts are rated at  ing bar or a 1" diameter black iron pipe can be put through the two  10A at 600 Vac, 0.75A at 125 Vdc, and 0.25A at 250 Vdc. holes above the hooks, allowing two people to carry the breaker  Number of below waist level from either side of the breaker. Switch Elements Product Number List Price  

One lifting bar is supplied with every five draw-out breakers at  no cha charge. rge. Frame Rating

Product Number

All

TDOLB

2 N O/2 N C

SDO PS2L

 

$177.00

4 N O/4 N C

SDO PS4L

 

$256.00

6 N O/6 N C

SDO PS6L

 

$336.00

List Price    

$104.00

distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

5-30

BuyLog Catalog

www.geelectrical.com  

Rev. 12/04 

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break I Circuit Breakers  Ratings and Trip Characteristics 

     S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

Power Break I Circuit Breakers for DC Applications and Replacement AC Needs  The GE line of Power Break I insulated case circuit breakers offers the rugged, reliable sys-  tem protection critical for heavy-duty DC power applications and for the replacement, add-  on and hole-filler needs of existing AC applications. Power Break circuit breakers are rated  up to 200,000 amperes rms symmetrical interrupting capacity without fuses or current lim-  iters. The Power Break design consists of five physical envelope sizes, providing protection  from 100 to 4000 amperes. Power Break I is a versatile breaker, breaker, designed for a wide variety of applicatio applications ns with features  including temperature temperature insensitive trip units, push-to-open and close buttons, maximum five-  cycle close time, UL Listed, field-installable rating plugs to change a breaker’s rating, UL Listed, (file E11592), field-installable field-installable accessories, easy to operate, rotary, rotary, charge storage handle.

5

800A Envelope 

A full line of selective tripping characteristics can be used to provide overcurrent protection  from overloads, short circuits and ground faults. Additionally, local trip indicators (targets)  visually signal long-time, short-time, instantaneous and ground fault trips. Power Break I circuit breakers with enhanced MicroVersaTrip solid state trip units and  MagneTrip dual-magnetic trip units offer application flexibility for ac as well as dc systems. Power Break with MagneTrip is rated up to 700 Vdc and 750 Vac. MagneTrip is 100 percent rated for ac or dc power distribution systems. MagneTrip also  offers interchangeable trips for 3000 ampere envelope size. A full line of Power Break draw-out substructures, interlocks, accessories, internal electrical  operators, connectors, a portable digital test kit, and a portable battery power pack is available. MicroVersaTrip trip units for Power Break insulated case circuit breakers digitally measure  the true RMS (heating) value of the current, regardless of the wave shape, by RMS digital  sensing of sinusoidal and non-sinusoidal currents.

2000A Envelope 

Features  —High-dielectric strength, glass reinforced insulating case for increased durability and safety of operation. —Interphase barrier partitions mesh with breaker cover to completely isolate each pole for high transient voltage withstandability. —Green (OFF), Red (ON), indicators display the position of the breaker contacts. —Extra heavy-duty, low torque-handle mechanism for simple, stored energy charging. —Easy quick-make, quick-break UL-Listed close/open —Complete line of accessories, foroperation. field installation. —Short circuit ratings through 200,000 Amperes. —RMS digital sensing of sinusoidal and non-sinusoidal currents by the solid-state trip device. —Field-installable, interchangeable rating plus. —Two trip unit options:  —MicroVersaTrip Plus trip units for overcurrent protection. —MicroVersaTrip PM trip units for metering, protective relays, and GE POWER LEADER communications.

3000A Envelope 

4000A Envelope 

Publications and Reference:  See Section 21 for a list of additional product-related publications  distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

Rev. 12/04 

www.geelectrical.com

BuyLog Catalog

5-31   Prices and data subject to change without notice 

 

Insulated Case Circuit Breakers 

Power Break I Circuit Breakers       S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

5

Draw-Out Breakers 

Features  —Draw-Outs through 4000 amperes are UL Listed, 100% rated  —Modular design for simplified installation—6 basic sizes—800, 1600, 2000, 2500, 3000 and 4000 amperes—5-inch pole centers  —Screw racking mechanism provides positive racking motion  —Self aligning primary and secondary disconnects  —Four position draw-out—engaged, test, disengaged, fully  withdrawn—simplifies system testing and inspection  —Breaker position indicator clearly shows breaker position  —Provisions for padlocking breaker in test or disengaged position  —Mechanical interlock logic prevents movement of a closed  breaker  —Suitable for reverse feeding  TC3030TT 

Description  The draw-out assembly consists of a substructure housing unit  designed as a compact self supporting unit and a draw-out breaker  which must be ordered separately. The substructure contains  mounting holes, self supporting and secondary nect strips, extendable rails, andmale can plugs be ordered separatelydiscon-  for  installation in your switchboard or enclosure. The Power Break draw-out breaker is a self-contained, heavy duty  assembly designed to offer simplified breaker inspection without de-energizing the main bus structure. The draw-out breaker comes complete with racking mechanism  drive, wheels, primary and secondary disconnects and cooperating  interlock systems. Accessories such as dead-front shutters, position switches, and  padlock devices are available and field installable.

NOTE: These draw-out breakers are not suitable for use in old style  (TPD, THD) substructures. Breaker rotated for inspection 

distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

5-32

BuyLog Catalog

www.geelectrical.com  

Rev. 12/04 

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break I Circuit Breakers  How To Order  How To Order 

Pricing Example

GO-145C  

Power Break frames are factory configured either for  MicroVersaTrip Plus trip units only (frame suffix “T” or “TT”) or for  MicroVersaTrip PM trip units, (frame suffix “TR” or “TTR”). If provi-  sion for 24 Vdc trip unit control power for MicroVersaTrip Plus trip  units is required, or if provision for future upgrade to MicroVersaTrip  PM, is desired, select frames with “TR” or “TTR” suffixes from page  5-40. For draw-out frames select the appropriate substructure  mounted trip unit secondary disconnect from page 5-51.

1600 ampere frame, 100kA, 480 Vac IC rating, 1000 ampere sensor, 600 ampere frame, 100kA, 480 Vac IC rating, 1000 ampere sensor, 600  ampere rating plug, 100% rated draw-out construction, 120 Vac shunt  trip assembled, trip unit functions to include long-time (L), short-time  (S), high range instantaneous (H), 120 Vac electrical (motor) opera-  tion (E1), trip targets, draw-out substructure. Description

Product Number

Fram Fr ame e and and Su Suff ffix ix ($ ($86 8671 71 + $16 $1656 56))

THC1 TH C161 610T 0TTH THE1 E1

$27890.00

1. Determine the required breaker frame, IC/short-time rating, and  load requirements. Select appropriate stationary or draw-out  breaker frame product number and list price on page 5-40.

Trip Unit and Suffix Adder

C210LSH

  $2700.00

Rating Plug

TR10B600

  $178.00

Shunt Trip (Assembled)

TPST12S

 No Charge 1

2. Select and price the appropriate frame modification from page 5-42.

Draw-out Substructure

THDOS16E

  $3230.00 1

Secondary Disconnects (2)

TDOSD6S

 

3. Select the basic MicroVersaTrip trip unit to match the frame  ampere rating from page 5-43. 4. Select and price the trip unit suffix from page 5-43 and 5-44 to  match the required trip functions. Refer to page 5-37 for trip unit  characteristics.

$320.00 1

1GO-145A.

Power Break I Rating Plug (X) and Current Sensor (S) Rating  Frame Max. Sensor Rating Envelope Size  Rating (Amperes)  ( Amp Amper eres es)) ( S) S)

5. Select and price the required rating plug from page 5-45. The sen-  sor rating of the frame must match the sensor rating of the plug.

800

6. Select and price lugs and accessories from pages 5-51 through 5-52. Draw-out substructure should be priced from page 5-39 if  required. 7. When ordering, specify separate product numbers as follows. The  trip unit will be installed in the frame. Rating plugs will be shipped  separately. Specify “Assembled” for installed accessories. —Frame including modifications suffix  —Trip unit including function suffix  —Rating plug  —Lugs (if required)  —Accessories (if required) 

List Price  

800

Rati Ra ting ng Pl Plug ug A mpe mpere res s ( X) X)  

200

100, 150, 200

400

150, 200, 225, 250, 300, 400

800

300, 400, 500, 600, 700, 800

1600

1600

1000 1600

400, 600, 800, 1000 600, 800, 1000, 1200, 1600

2000

2000

2000

800, 1000, 1200, 1600, 2000

2500

3000

4000

1000

400, 600, 800, 1000

2000

800, 1000, 1200, 1600, 2000

2500

1600, 2000, 2500

3000

3000

2000, 2500, 3000

4000

4000

1600, 2000, 2500, 3000, 4000

S = Sensor ampere rating  X = Rating Plug amperes 

Product Number Construction 

TH P

MM

16

10

TT

E 1C

R Configured for

Circuit Breaker Current Interrupting Capacity

MicroVersaTrip PM trip unit

TP = Standard Break THP = Hi-Break ® TUP = Special Hi-Break 2 TC = Standard Break Draw-out THC = Hi-Break Draw-out

Auxiliary Breaker Frame Functions FC = Front Connected 1 E1-7 = Electrical Operation C = Concealed "ON" Button H = High Range Instantaneous Z = Zone Selective Interlocking

MagneTrip™ 2

Breaker Frame Rating 8 = 800 16 = 1600 20 = 2000

25 = 2500 30 = 3000 40 = 4000

Trip Type and Rati Rating ng TT = MicroVersaTrip™ Plus or PM Programmer

Sensor Current Rating (Amperes) Related to breaker sensor rating (MicroVersaTrip) or continuous current rating (MagneTrip Trip Unit).

2 = 200A 4 = 400A   8 = 800A 10 = 1000A

16 = 1600A 20 = 2000A 25 = 2500A 30 = 3000A 40 = 4000A

Publications and Reference:  See Section 21 for a list of additional product-related publications  distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

1Stationary breakers only. 2 MagneTrip only.

Note: This information is provided for use interpreting product number. It cannot be used to build product numbers.

     S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     I      R      N      I      C

5

www.geelectrical.com

Rev. 12/04 

BuyLog Catalog

5-33   Prices and data subject to change without notice 

 

Insulated Case Circuit Breakers 

Power Break I Circuit Breakers       S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

5

Ratings and Trip Characteristics 

The interruption ratings and voltages shown in the table are maximum ratings. A circuit  breaker of the type given in the left-hand column may be applied at the given circuit voltage  in any electrical distribution system where the available fault current at the load terminals  of the breaker does not exceed the value in the table. That circuit breaker type may also be  applied at intermediate valuesdoes of circuit voltage provided current at the  load terminals of the breaker not exceed the value inthe theavailable table for fault the higher value of  voltage.

Interrupting Capacity  Envelope Size  Type of Construction Max. Short time Rating, kA1 240Vac   480Vac Standard Break 60 0Vac 250Vdc2,3 240Vac 480Vac   60 0Vac 60 Hi-Break 250Vdc2,3 500Vdc2 600Vdc2   750Vac Special Hi-Break4 700Vdc

800 A

16 00 A

2000A

3000A

4000A

25 65 65 42 – 10 0 10 0 65 – – – – –

30 85 65 50 22 125 100 65 35 – – – –

30 85 65 50 – 125 10 0 65 – – – – –

42 100 100 85 42 20 0 150 100 85 65 65 35 65

42 10 0 10 0 85 42 20 0 150 10 0 85 65 65 35 65

1With "H" option MicroVersaTrip trip unit only. 600 Vac, 50/60 Hertz, 500 ms. Not available on 4000A

stationary breaker. 2 DC ratings apply only to Power Break breaker with MagneTrip trip unit. 3 1600 A frame MagneTrip (TPMM, THPMM, TCMM, and THCM) also rated 30kA, 500 Vdc, with poles in

series for ungrounded battery applications. 4 Ratings apply only to Power Break breaker with MagneTrip trip unit Type TUPMM. Not UL Listed.

Power Break Molded Case Switch Withstand Ratings 

Switch Frame Size (Amperes)

Continuous Current Rating (Amperes)

Short-Time Rating, rms  Rating, Sym Amperes at 600 Vac Max., 500 ms Max.

80 0 160 0 200 0 250 0 250 0 300 0 400 0

80 0 160 0 20 0 0 20 0 0 250 0 30 0 0 40 0 0

25,000 30,000 30,000 42,000 42,000 42,000 42,000

Suitable on 200,000 ms Sym Ampere Fault Circuit when protected by Class L Fuses as Follows: Line Size Max. Fu Fuse Ampere Rating

Load Side Max. Fu Fuse Ampere Rating

20 0 0 2500 2500 2500 2500 40 005 40 005

80 0 1600 20 00 2500 2500 30005 40005

Short Circuit Withstand Rating   when Protected by Power Break   Breaker with MicroVersaTrip Plus or   MicroversaTrip PM Trip Unit   Breaker   Frame Size   (Amperes) 80 0 20 0 0 20 0 0 40 0 0 40 0 0 40 0 0 40 0 0

480 Vac

600 Vac  

10 0,000 10 0,000 10 0,000 10 0,000 10 0,000 10 0,000 10 0,000

65,000 65,000 65,000 65,000 65,000 65,000 65,000

5 Use only Hi-Break breaker with 4000 ampere fuses.

Dimensions and Weights  Complete dimensions and weight information can be found in the Power Break I Application  Guide, GET-6211.

distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

5-34

BuyLog Catalog

www.geelectrical.com  

Rev. 12/04 

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break I Circuit Breakers  Ratings and Trip Characteristics 

MagneTrip MagneTri p Trip Unit Characteristics  Curre Cur rent nt Rati Ra ting ngs s (Amp (A mper eres es))

Ampere Ampe re Se Sett ttin ing g (Mul (M ulti tipl ple e of currre cu rent nt ra rati ting ng))

Long Time Tim e Dela De lay y (Sec (S ec.)  .) 1

20 0, 400, 600 800, 100 0

0.7-1.0 0.7-1.0

4 4

3-10 3-10

0.04 0.04

3-10 3-10

None None

1200

0.7-1.0

4

3-8.2

0.04

3-8.2

None

1600

0.7-1.0

4

3-7.5

0.04

3-7.5

None

60 0, 800, 10 00

0.7-1.0

4

3-10

0.07

3-10

42,00 0

1200

0.7-1.0

4

3-8.2

0.07

3-8.2

42,00 0

1600

0.7-1.0

4

3-7.5

0.07

3-7.5

42,00 0

20 00

0.7-1.0

4

3-6.8

0.07

3-6.8

42,00 0

2500

0.7-1.0

4

2.3-5.5

0.07

2.3-5.5

42,00 0

30 0 0

30 00

0.7-1.0

4

3-5.3

0.07

3-5.3

42,00 0

40 0 0

40 00

0.7-1.0

4

2.2-4

0.07

2.2-4

42,00 0

Fra rame me Size Si ze

1600

2500

 

Short Time Shor Sh ortt-ti time me Pick Pi ckup up (M (Mul ulti tipl ple e of curr current ent ratin rating) g)

Adjustable Fixed   Instan Inst anta tane neou ous s In Inst stan anta tane neou ous  s  Dela De lay y Pick Pi ckup up (M (Mul ulti tipl ple e Over Ov erri ride  de  (Sec.)  (Sec. ) 2  of curre current nt rating) rating) (Ampe (Amperes)  res) 

1Time delay shown at 600 percent of breaker current rating at lower limit to trip time curve. 2 Time delay shown at 10X breaker current rating at lower limit of time curve.

Complete dimension and weight information can be found in the Power Break I application guide, GET-6211.

Publications and Reference:  See Section 21 for a list of additional product-related publications  distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

     S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

5

Rev. 12/04 

www.geelectrical.com

BuyLog Catalog

5-35   Prices and data subject to change without notice 

 

Insulated Case Circuit Breakers 

Power Break I Circuit Breakers       S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

5

Trip Unit Features 

Two Choices Of Advanced, Digital Solid-State Trip Units  Enhanced MicroVersaTrip Plus and MicroVersaTrip PM trip  units give you two ways to monitor and control the Power Power Break I  breaker with unprecedented ease. Through the simple keypad, the  trip unit lets you program and display a variety of functions including  tripping characteristics, remote communications, status information  and protective relaying, and allows integration with GE POWER  LEADER Power Management Systems. The trip unit display also  allows viewing of many standard metering parameters as well as  pickup alarms, trip target indications and fault status information. Enhanced MicroVersaTrip Plus and MicroVersaTrip PM trip units  use GE’s proven technique of measuring true rms currents (and  voltages for MicroVersaTrip PM trip units) of both sinusoidal and  harmonically distorted waveforms. The frequent sampling (64 times  per cycle) allows precise calculations of true rms current. The sam-  pling rate allows allows waveform measurements up to the 31st harmonic  to achieve accuracies of 99%. GE’s true rms sensing avoids potential  underprotection or overprotection problems associated with peak-  sensing tripping systems. The enhanced trip unit design includes a wide range of functions  and adds many new features: 

Trip operations counter  —The number of long-time, short-time, instantaneous and ground  fault trips are individually counted and displayed.

Enhanced MicroVersaTrip Plus and MicroVersaTrip PM Trip  Units have been specifically designed to integrate with the  extensive capabilities offered by Power Break circuit breakers.

Features exclusive to MicroVersaT MicroVersaTrip rip PM Tri Trip p Units 

Trip information  Communications  —On overcurrent faults, the trip unit displays fault pickup, the type  —All information can be viewed on the LCD display or  of fault, the magnitude of the fault current and the phase the  communicated over a POWER LEADER Power  fault occurred on. Management Managem ent System network. network. New display  —Ergonomic, 5-button keypad  —New targets with international symbols  —High-resolution LCD display for local 3-phase ammetering  —New status and setup displays for greater ease of use  —True rms sensing for accurate response to high harmonic 

Demand/peak demand  —The trip unit can display a rolling average of power demand  and peak power demand at user-selected user-selected intervals from 5 to  60 min minutes  utes 

content waveforms for Long-Time, Short-Time, and Ground  Fault protect protection. ion. —50/60 Hz operation. —Interchangeable, UL Listed trip units and rating plugs with test  set jack for TVRMS2 TVRMS2 test set. —EMI immunity per ANSI C37.90.

Local and remote metering  —Amperes, volts, frequency  —Real power, total power  —Accumulated energy  Protective relays include  —Current and voltage unbalance  —Overvoltage  —Undervoltage  —Power reversal  —Power reversal direction setup 

distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

5-36

BuyLog Catalog

www.geelectrical.com  

Rev. 12/04 

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break I Circuit Breakers with Enhanced  MicroVersaTrip Plus and MicroVersaTrip PM Trip Units 

     S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

Technical Data  Trip Unit Characteristics 

Enhanced MicroVersaTrip Plus and PM Tri Trip p Unit Characteristics  Long-Time Sensor Rating (Amperes) (S) 

Frame Rating  Max. Envelope Size  Ampere

Setting (C) (Pick-Up) MulCurrent Multipl tiple e of of Rati R ating ng Plug Ampere Amp eres s (X) (X)

Short-Time Delay  Del ay 1  (Seconds) 

800

800

200, 400, 800

2.4, 4.9, 9.8, 20

1600

1600

1000, 1600

2.4, 4.9, 9.8, 20

2000

2000

2000

2500

1000, 2000, 2500

3000

3000

4000

4000

3000 4000

of Pick-Up Curr Cu rren entt (Multiple Setti Set ting ng)) (C (C))

Dela De lay y (S (Sec econ onds ds)  )  I 2 T in 1 0.40

2.4, 4.9, 9.8, 20

0.5 thru 1.0 in increments of 0.05

 

1.5 thru 9.0 in increments of 0.05

2.4, 4.9, 9.8, 20

I2 T out2 .10, .21, .35

2.4, 4.9, 9.8, 20

Trip Unit Characteristics (continued)  Adjustable Instantaneous Pick-Up without ST (Multiple of Envelope Size  Rating Plug Amperes) (X) 

Adjustable Instantaneous Pick-Up with ST (Multiple of Rating Plug Amperes) (X) 

High Range Instantaneous (Multiple of Frame Short-Time Rating) (H) 

Ground Fault  Pick-Up (Multiple of Sensor Ampere Rating) 

1.5 thru 10.0 in 0.5 increments

1.5 thru 15.0 in 0.5 increments

1.5 thru 10.0 in

1.5 thru 15.0 in

0.20 thru 0.60 in

2000

0.5 increments 1.5 thru 10.0 in 0.5 increments

0.5 increments 1.5 thru 15.0 in 0.5 increments

increments of 0.01 0.20 thru 0.60 in increments of 0.01

3000

1.5 thru 10.0 in 0.5 increments

1.5 thru 13.0 in 0.5 increments

0.20 thru 0.37 in increments of 0.01

4000

1.5 thru 9.0 in 0.5 increments

1.5 thru 9.0 in 0.5 increments

0.20 thru 0.30 in increments of 0.01

800 1600

Delay with I 2 T Seconds 

0.20 thru 0.60 in increments of 0.01

1.0

Delay 3  wit  witho hout ut I 2 T Seconds  .10, .21, .35 .10, .21, .35

.37 at 200% of pick-up at lower limit of band

.10, .21, .35 .10, .21, .35 .10, .21, .35

1 Time delay shown at 600% of current setting at lower limit of band. 2 Time delay shown at lower limit of each band. All pick-up tolerances are ± 10%. 3 Time delay shown at lower limit of each band. Ground fault pick-up not to exceed 1200 amperes.

X = Rating plug amperes  S = Sensor ampere rating  C = Long-time current setting (pick-up)  H = Short-time rating 

MicroVersaTrip PM Trip Unit Characteristics 4  Trip Unit Suffix  Function Communications

Description   —POWER LEADER Communications Bus Link

M (Metering)

P (Relaying)

PM (Metering & Relaying)  

STD

STD

STD

STD

STD

STD

Amperes (A, kA)5

Selectable Phase Current ±2.5%

Voltage (V)

L-L or L-N Volts ±1.5%

 • 

 • 

Energy (kWh, MWh, GWh)

Total Energy Usage on Brkr ±4%

 • 

 • 

Real Power (kW/MW)

L-L or L-N Power ±4%

 • 

 • 

Total Power (kVA/MVA)

L-L or L-N Power ±4%

 • 

 • 

Frequency (Hz)

Circuit Frequency ± 1Hz

 • 

 • 

 • 

 • 

Demand & Peak Demand (kW) Under Voltage Trip

—Adjustable pickup 50-90% —Adjustable delay, 1-15 seconds OFF

 • 

 • 

Over Voltage Trip

—Adjustable pickup, 110-150% —Adjustable delay, 1-15 seconds OFF

 • 

 • 

Voltage Unbalance

—Adjustable pickup, 10-50% —Adjustable delay, 1-15 seconds OFF

 • 

 • 

Current Unbalance

—Adjustable pickup, 10-50% —Adjustable delay, 1-15 seconds OFF

 • 

 • 

Power Reversal

—Adjustable pickup, 10-990 kW —Adjustable delay, 1-15 seconds OFF

 • 

 • 

4 MicroVersaTrip PM functions require 24 Vdc control power. 5 Ampere reading also standard on MicroVersaTrip Plus.

Publications and Reference:  See Section 21 for a list of additional product-related publications  distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

5

www.geelectrical.com

Rev. 12/04 

BuyLog Catalog

5-37   Prices and data subject to change without notice 

 

Insulated Case Circuit Breakers 

Power Break I Circuit Breakers with MagneTrip Unit       S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

How To Order  Stationary Breakers and Special Purpose Hi-Break 

Power Break Breaker with MagneTrip Trip Unit—Stationary, UL Listed, 100% Equipment Rated

GO-145M  

600 Vac, 250 Vdc (Standard Break), 600 Vdc 1 (Hi-Break) Non-interchangeable Trip Unit  Circuit Breaker Envelope Size (Amperes)

Circuit Breaker Frame Size (Amperes)

5 160 0

40 00

160 0

400 0

Continuous   Current Rating (Amperes)

Standard Break Product Number 2  

200

TPMM5602

 

$13890.00

 

THPMM5602

 

$14887.00

400

TPMM5604

THPMM5604

TPMM5606

$13890.00 $13890.00

 

600

   

 

THPMM5606

   

$14887.00 $14887.00

Hi-Break   Product Number 2   

List Price

List Price 

800

TPMM5608

 

$13890.00

 

THPMM5608

 

$14887.00

1000

TPMM5610

 

$13890.00

 

THPMM5610

 

$14887.00

1200

TPMM5612

 

$13890.00

 

THPMM5612

 

$14887.00

1600 40 0 0

TPMM5616 TPMM96402

 

$13890.00

   

THPMM5616 THPMM96402

 

$14887.00

$60399.00

$73666.00

3000 30 00 Am Ampe pere re En Enve velo lope pe Si Size ze Po Powe werr Bre Break ak wi with th Ma Magne gneT Tri rip p Tri Trip p Uni Unit— t—St Stat atio ionar naryy, UL UL Lis Liste ted, d, 10 100% 0% Eq Equi uipm pmen entt Rat Rated ed

GO-1 GO -145 45M  M 

600 Vac, 250 Vdc (Standard Break), 600 Vdc (Hi-Break) Interchangeable Trip Unit  Circuit Breaker Frame Size (Amperes)

Continuous Current Rating (Amperes)

250 0

30 0 0

Standard Break Complete Product Number 2  

60 0

TPMM7606

Hi-Break   Complete   Product Number 2   

List Price  

$14988.00

 

THPMM7606

List Price   

$18902.00

80 0

TPMM7608

 

$14988.00

 

THPMM7608

 

$18902.00

100 0

TPMM7610

THPMM7610

TPMM7612

$14988.00 $14988.00

 

120 0

   

 

THPMM7612

   

$18902.00 $18902.00

$14988.00 $14988.00

 

THPMM7616

 

THPMM7620

   

$18902.00 $18902.00

160 0

TPMM7616

20 00

TPMM7620

   

250 0

TPMM7625

 

$28484.00

 

THPMM7625

 

$36538.00

300 0

TPMM8630

 

$37577.00

 

THPMM8630

 

$46381.00

Speciall Hi-Bre Specia Hi-Break ak Power Break Breake Breakerr with with MagneT MagneTrip rip Trip Unit Unit—Stat —Stationary ionary

GO-145M  GO-1 45M 

750 Vac, 700 Vdc, Interchangeable Trip Unit, Not UL Listed  Circuit Breaker Envelope Size (Amperes)

30 00

Circuit Breaker Frame Size (Amperes)

250 0

30 0 0

Continuous   Current Rating (Amperes)

Complete   Product Number 2  

60 0

TUPMM7706

List Price   

$21579.00

80 0

TUPMM7708

 

$21579.00

100 0

TUPMM7710

 

$21579.00

120 0

TUPMM7712

 

$21579.00

160 0

TUPMM7716

 

$21579.00

20 00

TUPMM7720

 

$21579.00

250 0

TUPMM7725

 

$41660.00

30 00

TUPMM8730

 

$52905.00

3,4

40 00

40 0 0

40 00

$84039.00

TUPMM9740

Power Break Breaker with Instantaneous Only—Stationary

GO-145M  

600 Vac, 250 Vdc, Non-Interchangeable Trip Unit, Not UL Listed  Circuit Breaker Envelope Size (Amperes)

Circuit Breaker Frame Size (Amperes)

Continuous   Current Rating (Amperes)

1600

1600

160 0

TPMM5616M

 

$13890.00

250 0

20 00

TPMM7620M

 

$14988.00

250 0

250 0

TPMM7625M

 

$28484.00

30 0 0

30 00

TPMM8630M

 

40 0 0

40 00

TPMM9640M2

$37577.00 $60399.00

30 00 40 00

Standard Break   Product Number

List Price  

14000-Ampere frame only  2 Product Number with standard trip functions. For optional trip functions and pricing, see page 5-39. 3 80% rated  4 Non-interchangeable trip 

distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

5-38

BuyLog Catalog

www.geelectrical.com  

Rev. 12/04 

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break I Circuit Breakers with Magne Trip Trip Unit  How To Order  Stationary Breakers, Draw-Out Breakers 

Power Break Breaker with MagneTrip Trip Unit—Draw-Out UL Listed, 100% Equipment Rated

     S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

GO-145M  

600 Vac, 250 Vdc (Standard Break), 600 Vdc 1 (Hi-Break)  Non-Interchangeable Trip Unit  Circuit Breaker

Circuit Breaker

Continuous

Standard Break

Hi-Break   2 

Envelope Enve lope Size (Ampe (Amperes) res)

160 0

40 0 0

Frame Fram e Size (Ampe (Amperes) res) Curr Current ent Rating (Ampe (Amperes) res) 20 0 40 0 60 0 160 0 80 0 10 0 0 120 0 160 0 40 0 0 40 0 0



Product Numbe Product Number  r  TCMM5602 TCMM5604 TCMM5606 TCMM5608 TCMM5610 TCMM5612 TCMM5616 TCMM9640

Li st st P ri ri ce ce  

$17187.00

 

$17187.00

 

$17187.00

 

$17187.00

 

$17187.00

 

$17187.00

 

$17187.00

 

$71014.00

               

P ro ro du du ct ct N um umb er er   THCMM5602 THCMM5604 THCMM5606 THCMM5608 THCMM5610 THCMM5612 THCMM5616 THCMM9650

List Price 

3000 30 00 Am Ampe pere re Env Envel elop ope e Siz Size e Pow Power er Br Brea eak k Bre Break aker er wi with th Ma Magn gneT eTri rip— p—Dr Draw aw-O -Out ut,, UL UL Lis Liste ted, d, 100 100% % Equ Equip ipme ment nt Ra Rate ted d

 

$18450.00

 

$18450.00

 

$18450.00

 

$18450.00

 

$18450.00

 

$18450.00

 

$18450.00

 

$86462.00

5

GO-1 GO -145 45M  M 

600 Vac, 250 Vdc (Standard Break), 600 Vdc (Hi-Break) Interchangeable Trip Unit  Circuit Breaker Frame Size (Amperes)

2500

 

– 30 0 0

Continuous Current Rating (Amperes)

Standard Break Complete Product Number 2   

60 0 80 0 10 0 0 120 0 160 0 20 0 0 250 0 30 0 0

TCMM7606 TCMM7608 TCMM7610 TCMM7612 TCMM7616 TCMM7620 TCMM7625 TCMM8630

Hi-Break   Complete   Product Number 2   

List Price  

$19814.00

 

$19814.00

 

$19814.00

 

$19814.00

 

$19814.00

 

$19814.00

 

$33702.00

 

$43859.00

               

THCMM7606 THCMM7608 THCMM7610 THCMM7612 THCMM7616 THCMM7620 THCMM7625 THCMM8630

List Price   

$24096.00

 

$24096.00

 

$24096.00

 

$24096.00

 

$24096.00

 

$24096.00

 

$42143.00

 

$53114.00

Optional MagneTrip Unit Functions 3 

GO-145M 4 

Description

Product No. Suffix

Adjustable current plus adjustable short-time fixed instantaneous Inverted construction (stationary breaker only)

D B

List Price Adder    

$1075.00

 

$1244.00

Replacement MagneTrip Trip Units Continuous Current Rating (Amperes) 60 0 80 0 10 0 0 120 0 160 0 20 0 0 250 0 30 0 0

GO-148F

Replacement Trip Unit Product Number TPD706 TPDT08 TPDT10 TPDT12 TPDT16 TPDT20 TPDT25 TPDT30

Adjustable Current, Short-Time, Fixed Instantaneous

List Price

 

 

$4497.00

 

$4497.00

 

$4497.00

 

$4497.00

 

$4497.00

 

$4497.00

 

$8544.00 $11272.00

               

TPDT06D TPDT08D TPDT10D TPDT12D TPDT16D TPDT20D TPDT25D TPDT30D

14000-Ampere frame only  2 Product Number with standard trip functions. For optional trip functions see table. 3 Add suffix code letter to end of breaker frame product numbers. 4 For trip option on new breaker, add to complete breaker list price above.

Publications and Reference: See Reference:  See Section 21 for a list of additional product-related publications  distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

Inverted   Construction   (Stationary Only)

List Price

 

 

$5572.00

 

$5572.00

 

$5572.00

 

$5572.00

 

$5572.00

 

$5572.00

 

$9619.00 $12347.00

               

TPDT06B TPD708B TPDT10B TPDT12B TPDT16B TPDT20B TPDT25B TPDT30B

List Price    

$5741.00

 

$5741.00

 

$5741.00

 

$5471.00

 

$5471.00

 

$5471.00

   

$9788.00 $12516.00

 

www.geelectrical.com

Rev. 12/04 

BuyLog Catalog

5-39   Prices and data subject to change without notice 

 

Insulated Case Circuit Breakers 

Power Break I Circuit Breakers with MicroVersaTrip Plus or PM Trip Units       S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

5

Frame Selection  Basic Frame Selection, Stationary, UL Listed, 100% Equipment Rated, Suitable for Reverse Feed

GO-145C  

Frame Selection for Use with MicroVersaTrip Plus Trip Units Only  Circuit Breaker Envelope Size (Amperes)

Circuit Breaker Frame Size (Amperes)

Sensor   Rating (Amperes)

80 0 80 0 80 0 160 0 160 0 20 0 0 30 0 0 30 0 0 30 0 0 30 0 0 40 0 0

80 0 80 0 80 0 160 0 160 0 20 0 0 250 0 250 0 250 0 30 0 0 40 0 0

20 0 40 0 80 0 10 0 0 160 0 20 0 0 10 0 0 20 0 0 250 0 30 0 0 40 0 0

Standard Break 1

  Product Number

Hi-Break 1 Product   Number

List Price

TP82TT TP84TT TP88TT TP1610TT TP1616TT TP2020TT TP2510TT TP2520TT TP2525TT TP3030TT TP4040T2

 

$13815.00

 

$13815.00

 

$13815.00  

$16890.00

 

$16890.00

 

$17917.00

 

$19710.00

 

$19710.00

 

$34750.00

 

$44230.00 $72945.00

                     

List Price  

THP82TT THP84TT THP88TT THP1610TT THP1616TT THP2020TT THP2510TT THP2520TT THP2525TT THP3030TT THP4040T2

 

$14950.00

 

$14950.00

 

$14950.00  

$18779.00

 

$18779.00

 

$20985.00

 

$23085.00

 

$23085.00

 

$43540.00

 

$55435.00 $88990.00

Frame Selection 3  for Use with MicroVersaT MicroVersaTrip rip PM or Plus Trip Units  Standard Break 1

 

Circuit Breaker Envelope Size (Amperes)

Circuit Breaker Frame Size (Amperes)

Sensor   Rating (Amperes)

80 0 80 0 80 0 160 0 160 0 20 0 0 30 0 0 30 0 0

80 0 80 0 80 0 160 0 160 0 20 0 0 250 0 250 0

20 0 40 0 80 0 10 0 0 160 0 20 0 0 10 0 0 20 0 0

TP82TTR TP84TTR TP88TTR TP1610TTR TP1616TTR TP2020TTR TP2510TTR TP2520TTR

30 0 0 30 0 0 40 0 0

250 0 30 0 0 40 0 0

250 0 30 0 0 40 0 0

TP2525TTR TP3030TTR TP4040TR2

Product Number

Hi-Break 1 Product   Number

List Price  

$14305.00

 

$14305.00

 

$14305.00  

$17375.00

 

$17375.00

 

$18405.00

 

$20200.00

 

$20200.00

   

$35235.00 $44715.00 $73430.00

List Price  

               

THP82TTR THP84TTR THP88TTR THP1610TTR THP1616TTR THP2020TTR THP2510TTR THP2520TTR

     

THP2525TTR THP3030TTR THP4040TR2

 

$15440.00

 

$15440.00

 

$15440.00  

$19270.00

 

$19270.00

 

$21475.00

 

$23570.00

 

$23570.00

   

$44030.00 $55920.00 $89480.00

Basic Frame Selection, Draw-Out, UL-Listed, 100% Equipment Rated, Suitable for Reverse Feed

GO-145C  

Frame Selection for Use with MicroVersaTrip Plus Trip Units Only  Circuit Breaker Envelope Size (Amperes)

Circuit Breaker Frame Size (Amperes)

Sensor   Rating (Amperes)

Standard Break 1

  Product Number

Hi-Break 1

List Price

Product   Number

List Price  

$16300.00

THC82TT4,5

$17475.00

TC84TT4,5 TC88TT4,5 TC1610TT TC1616TT TC2020TT TC2510TT TC2520TT TC2525TT TC3030TT

$16300.00

THC84TT4,5 THC88TT4,5 THC1610TT THC1616TT THC2020TT THC2510TT THC2520TT THC2525TT THC3030TT

$17475.00

THC4040T T

80 0 80 0 80 0 160 0 160 0 20 0 0 30 0 0 30 0 0 30 0 0 30 0 0

80 0 80 0 80 0 160 0 160 0 20 0 0 250 0 250 0 250 0 30 0 0

20 0 40 0 80 0 10 0 0 160 0 20 0 0 10 0 0 20 0 0 250 0 30 0 0

TC82TT4,5

40 0 0

40 0 0

40 0 0

TC4040T T

 

$24295.00

 

$24295.00

 

$41940.00

 

$52485.00

                   

 

$87415.00

 

$16300.00  

$21175.00

 

$21175.00

 

$22090.00

$17475.00  

$23420.00

 

$23420.00

 

$25575.00

 

$28130.00

 

$28130.00

 

$51595.00

 

$64690.00

 

$106070.00

Frame Selection 3  for Use with MicroVersaTrip PM or Plus Trip Units  Circuit Breaker Envelope Size (Amperes)

Circuit Breaker Frame Size (Amperes)

Sensor   Rating (Amperes)

80 0 80 0 80 0 160 0 160 0 20 0 0 30 0 0 30 0 0 30 0 0 30 0 0 40 0 0

80 0 80 0 80 0 160 0 160 0 20 0 0 250 0 250 0 250 0 30 0 0 40 0 0

20 0 40 0 80 0 10 0 0 160 0 20 0 0 10 0 0 20 0 0 250 0 30 0 0 40 0 0

Standard Break 1

  Product Number

TC82TTR4,5 TC84TTR4,5 TC88TTR4,5 TC1610TTR TC1616TTR TC2020TTR TC2510TTR TC2520TTR TC2525TTR TC3030TTR TC4040TTR

Hi-Break 1 Product   Number

List Price $16785.00 $16785.00 $16785.00  

$21660.00

 

$21660.00

   

$22380.00 $24785.00

 

$24785.00

 

$42430.00

 

$52975.00

 

$87905.00

                     

THC82TTR4,5 THC84TTR4,5 THC88TTR4,5 THC1610TTR THC1616TTR THC2020TTR THC2510TTR THC2520TTT THC2525TTR THC3030TTR THC4040TTR

List Price   $17965.00 $17965.00 $17965.00  

$23910.00

 

$23910.00

   

$26060.00 $28615.00

 

$28615.00

 

$52080.00

 

$65180.00 $106555.00

1For frame modification, i.e. electrically operated, see page 5-42. 2 Not rated 100%. 3 Includes provision for MicroVersaTrip MicroVersaTrip PM functions. Use for MicroVersaTrip MicroVersaTrip Plus when connections for 24 Vdc trip unit control power required. 4 

to 24 secondary disconnects. For up to 48 secondary disconnects, use Product Number TCL-TT or TCL-TTR and add $1600.00 to List Price. 5 Up Small frame size.

distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

5-40

BuyLog Catalog

www.geelectrical.com  

Rev. 12/04 

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break I Circuit Breakers  Stationary Switches, Draw-out Switches  800-4000 Amperes  600 Vac  500 Vdc (250 Vdc where noted)  Suitable for reverse feed  Power Break Molded Case Switch—Stationary

GO-145D  

600 Vac, 500 Vdc (Standard Break), 600 Vdc (Hi-Break)  Switch Envelope Size (Amperes)

Switch Frame Size (Amperes)

Continuous   Current Rating (Amperes)

Standard Break 600 Vac/500 Vdc

List Price

80 0

80 0

80 0

TPYY36081

$5671.00

 





$7452.00

 





$8380.00

 



160 0

160 0

160 0

TPYY56161

20 0 0

20 0 0

20 0 0

TPYY66201

30 0 0

250 0

20 0 0

TPYY7620

 

Hi-Break   600 Vac/600 Vdc

List Price  



$8380.00

 

THPYY7620

 

$10481.00

30 0 0

250 0

250 0

TPYY7625

 

$13335.00

 

THPYY7625

 

$16670.00

30 0 0

30 0 0

30 0 0

TPYY8630

 

$22565.00

 

THPYY8630

 

$28204.00

40 0 0

40 0 0

40 0 0

TPYY9640

 

$35794.00

 

THPYY9640

 

$44738.00

Power Break Molded Case Switch—Draw-Out

GO-145D  

600 Vac, 500 Vdc (Standard Break), 600 Vdc (Hi-Break)  Switch Envelope Size (Amperes)

Switch Frame Size (Amperes)

Continuous   Current Rating (Amperes)

Standard Break 600 Vac/500 Vdc

Hi-Break   600 Vac/600 Vdc

List Price

List Price  

80 0

80 0

80 0

TCYY36081

$7384.00

 





160 0

160 0

160 0

TCYY56161

$10751.00

 





20 0 0

20 0 0

20 0 0

TCYY66201

$11683.00

 





30 0 0

250 0

20 0 0

TCYY7620

 

THCYY7620

30 0 0

250 0

250 0

TCYY7625

   

$13205.00 $18552.00

 

THCYY7625

   

$15304.00 $21889.00

30 0 0

30 0 0

30 0 0

TCYY8630

 

$28843.00

 

THCYY8630

 

$34482.00

40 0 0

40 0 0

40 0 0

TCYY9640

 

$46411.00

 

THCYY9640

 

$55355.00

1Rated 250 Vdc 

Publications and Reference:  See Section 21 for a list of additional product-related publications  distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

     S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

5

www.geelectrical.com

Rev. 12/04 

BuyLog Catalog

5-41   Prices and data subject to change without notice 

 

Insulated Case Circuit Breakers 

Power Break I Circuit Breakers       S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

5

Frame Modification Features 

Power Break Frame Modification Suffix—AC and DC Breakers

GO-145C  

Circuit Breaker Envelope Size (Amperes)  Function 1

Electrical (Motor) Operation 2

800

1600

2000

3000

120 Vac 240 Vac

E1 N/A

E1 N/A

E1 N/A

125 Vdc

E3

E3

  24 Vdc

E5

  48 Vdc

E6

  72 Vdc

E7

  Front Connected

4000  

List Price Adder 

E1 E2 3

E1 E2 3

$4475.00 $4930.00

E3

E3

E3

$4930.00

E5

E5

E5

E5

$4930.00

E6

E6

E6

E6

$4930.00

E7

E7

E7

E7

$5380.00

Suitable for front or rear connection as standard

Add suffix FC Supplied as to Product No.4 standard

No price adder

  Hidden "ON" Button

Add suffix C to frame Product Number

  $148.00

  High Range Instantaneous (Air Core Sensors)

Add suffix H to frame Product Number 5

Price adder is on trip unit only

Add suffix Z to frame Product Number when zone interlock function is included in trip unit (Z1 or Z2). Requires 24 Vdc Control power.

Price adder is on trip unit only

  Zone Selective Interlock Wiring Terminal Block

TC3030TT 

1 Modification suffix must be developed in the following order: H/Z/FC/E1-7/C, ending with R:

TP82TTE1CR. 2 Shunt trip or undervoltage release included with motor operation (specify with order). 3 Not UL Listed. 4 Stationary frames only. 5 Not available on 4000A stationary b reakers.

distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

5-42

BuyLog Catalog

www.geelectrical.com  

Rev. 12/04 

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break I Circuit Breakers with Enhanced  MicroVersaTrip Plus and MicroVersaTrip PM Trip Units 

     S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

How To Order  Trip Unit Characteristics and Selection  Power Break Basic MicroVersaTrip MicroVersaTrip Tri Trip p Unit Selection  Circuit Breaker Envelope Size (Amperes) 

Circuit Breaker F ra ra me me Siz Size e (Am (Ampe pere res) s)

800

200

C202

400

C204

800

C208

1000

C210

1600

C216

2000

C220

1000

C210

2000

C220

2500

C325

3000

3000

C330

4000

4000

C440

800

1600

Basic Trip Unit Product Number 

Sens Se nsor or Ra Rati ting ng (A (Amp mpe e re re s)  s) 

5

1600

2000

2000

2500 3000

4000

Power Break Trip Unit Suffix Selection  MicroVersaTrip MicroVersaT rip Plus with Selectable Phase Ammeter—Trip Indicators Standard  Trip Unit Suffix 1

List Price Adder, GO-145C 1

Trip Indicators 

Selectable Phase Ammeter 

Long-Time (L) 

Short-Time (S) 

Inst. (I) 

High Inst. (H) 

Ground 2 Fault 3  GF Zone  (G)  Interlock (Z1) 4 

GF/ST Zone Interlock (Z2) 4 

Adjustable Instantaneous  LI LIG

 

$690.00

• 

 • 

 • 

 • 

$2205.00

 • 

 • 

 • 

 • 

 • 

 

$2875.00

 • 

 • 

 • 

 • 

 • 

$2260.00

 • 

 • 

 • 

 • 

 • 

 

$3772.00

 • 

 • 

 • 

 • 

 

LIGZ1 LSI

 

 

 • 

 • 

LSIGZ1

 

$4445.00

 • 

 • 

 • 

 • 

 • 

 • 

LSIGZ2

 

$5120.00

 • 

 • 

 • 

 • 

 • 

 • 

LSIG

 • 

 •   • 

Fixed High Range Instantaneous 5  LSH LSHG

1

   

$3105.00

 • 

 • 

 • 

 • 

 • 

$4310.00

 • 

 • 

 • 

 • 

 • 

 • 

LSHGZ1

 

$5290.00

 • 

 • 

 • 

 • 

 • 

 • 

LSHGZ2

 

$5965.00

 • 

 • 

 • 

 • 

 • 

 • 

 •   • 

Add suffix to basic trip unit product number. Make List Price addition for trip unit suffix.

2 For 3

single-phase 3-wire or 3-phase, 4-wire application s, order appropriate neutral current sensor and price separately from page 5-46. Use code GD in place of G for a defeatable Ground Fault Option (not UL listed) i.e. LSIGD, and add $575.00 to list price. 4 Requires purchase of zone selective interlock module(s) TypeTIM1 (120 Vac Vac control voltage). List Price $402.00, GO-245B. 5 Not available on 400 0A stationary breaker frame. Requires frame with "H" suffix code. See page 5-40.  

Publications and Reference:  See Section 21 for a list of additional product-related publications  distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

www.geelectrical.com

Rev. 12/04 

BuyLog Catalog

5-43   Prices and data subject to change without notice 

 

Insulated Case Circuit Breakers 

     S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

Power Break I Circuit Breakers with Enhanced  MicroVersaTrip Plus and MicroVersaTrip PM Trip Units  How To Order  Trip Tri p Unit Characteristics and Selection (continued)  Power Break Trip Unit Suffix Selection  MicroVersaTrip MicroVersaT rip PM with Metering and Communications—T Communications—Trip rip Indicators Standard 1  Trip Unit 2  Suffix 2 

List Price Adder, GO-145C 2 

Trip Indicators 

Selectable Phase Ammeter 

Long-Time (L) 

Short-Time (S) 

Inst. (I) 

Ground Gro und Fau Fault lt 4  (G) 4 

High Inst. (H) 

GF Zone Interlock (Z1) 5 

GF/ST Zone Interlock (Z2) 5 

Adjustable Instantaneous   

LIM

5

$2415.00  

LIGM

 

LIGZ1M

 

LSIM

 

LSIGM

• 

 • 

 • 

 • 

$3930.00

 

 • 

 • 

 • 

 • 

 • 

$4600.00

 • 

 • 

 • 

 • 

 • 

$3985.00

 • 

 • 

 • 

 • 

 • 

$5497.00

 • 

 • 

 • 

 • 

 • 

 • 

 • 

 • 

 • 

 • 

 • 

 • 

 • 

LSIGZ1M

 

$6170.00

 • 

LSIGZ2M

 

$6845.00

 • 

 • 

 • 

 • 

$4830.00

 • 

 • 

 • 

 • 

 • 

$6345.00

 • 

 • 

 • 

 • 

 • 

 • 

 •   • 

Fixed High Range Instantaneous 6   

LSHM

 

LSHGM LSHGZ1M

 

$7015.00

 • 

 • 

 • 

 • 

 • 

LSHGZ2M

 

$7690.00

 • 

 • 

 • 

 • 

 • 

 •   • 

 • 

Power Break Trip Unit Suffix Selection  MicroVersaTrip MicroVersaT rip PM with Protective Relays and Communications—T Communications—Trip rip Indicators Standard 1  Trip Unit Suffix 2 

List Price Adder, GO-145C  2 

Trip Indicators 

Selectable Phase Ammeter 

Long-Time (L) 

Short-Time (S) 

Inst. (I) 

High Inst. (H) 

Ground 3  Fault (G) 4 

GF Zone Interlock (Z1) 5 

GF/ST Zone Interlock (Z2) 5 

Adjustable Instantaneous  LIP

 

LIGP

$1955.00    

LIGZ1P LSIP

 

• 

 • 

 • 

 • 

$3470.00

 

 • 

 • 

 • 

 • 

 • 

 • 

 • 

$4140.00

 • 

 • 

 • 

$3525.00

 • 

 • 

 • 

 • 

 • 

$5037.00

 • 

 • 

 • 

 • 

 • 

 • 

LSIGZ1P

 

$5710.00

 • 

 • 

 • 

 • 

 • 

 • 

LSIGZ2P

 

$6385.00

 • 

 • 

 • 

 • 

 • 

 • 

$4370.00

 • 

 • 

 • 

 • 

 • 

$5885.00

 • 

 • 

 • 

 • 

 • 

 • 

 • 

 • 

 • 

 • 

 • 

 • 

 • 

 • 

 • 

 • 

 

LSIGP

 • 

 •   • 

Fixed High Range Instantaneous 6  LSHP

   

LSHGP LSHGZ1P

 

$6555.00

 • 

LSHGZ2P

 

$7320.00

 • 

 •   • 

Power Break Trip Unit Suffix Selection  MicroVersaTrip MicroVersaT rip PM with Metering, Protective Relays and Communications—T Communications—Trip rip Indicators Standard 1  Trip Unit Suffix 2  2 

List Price Adder, GO-145C 2  GO-145C 2 

Trip Indicators 

Selectable Phase Ammeter 

Long-Time (L) 

Short-Time (S) 

Inst. (I) 

High Inst. (H) 

Grou Gr ound nd Fa Faul ultt (G) 4  4 

GF Zone Interlock (Z1) 5  (Z1) 5 

GF/ST Zone Interlock (Z2) 5  (Z2) 5 

Adjustable Instantaneous  LIPM

 

LIGPM

$3680.00    

LIGZ1PM LSIPM LSIGPM

   

• 

 • 

 • 

 • 

$5265.00

 

 • 

 • 

 • 

 • 

 • 

$5865.00

 • 

 • 

 • 

 • 

 • 

$5250.00

 • 

 • 

 • 

 • 

 • 

$6762.00

 • 

 • 

 • 

 • 

 • 

 • 

LSIGZ1PM

 

$7435.00

 • 

 • 

 • 

 • 

 • 

 • 

LSIGZ2PM

 

$8110.00

 • 

 • 

 • 

 • 

 • 

 • 

 • 

 •   • 

Fixed High Range Instantaneous 6  LSHPM

 

$6095.00

 • 

 • 

 • 

 • 

 • 

$7610.00

 • 

 • 

 • 

 • 

 • 

 • 

LSHGZ1PM

 

$8280.00

 • 

 • 

 • 

 • 

 • 

 • 

LSHGZ2PM

 

$8955.00

 • 

 • 

 • 

 • 

 • 

 • 

LSHGPM

 

 •   • 

1

Requires 24 Vdc control power and frame with TT…R suffix. See page 5-40 . Add suffix to basic trip unit product number. Make List Price addition  for  for trip unit suffix. Requires frame with TT…R suffix. See page 5-40. 3 For single-phase 3-wire or 3-phase, 4-wire applications, order appropriate neutral current sensor and price separately from page 5-46. 2

4

code GD in place of G for defeatable Ground Fault Option (not UL listed) i.e. LSIGDPM, and   add $575.00 to List Price. Requires purchase of zone selective interlock module(s) TypeTIM1 (120 Vac control voltage). List Price $402.00, GO-245B. Not available on 400 0A stationary breaker frame. Requires frame with "H" suffix code. See page 5-40.

5 Use 6

distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

5-44

BuyLog Catalog

www.geelectrical.com  

Rev. 12/04 

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break I Circuit Breakers  How To Order  Rating Plug Selection  Power Break Rating Plus Selection 1  All Plugs List Priced at $89.00  Frame Size (Amperes)

Sensor Rating (Amperes)

GO-245A Current Rating (Amperes)

Rating Plug   Product Number  

100

TR2B100

20 0

400 800

 

 

80 0

1000

1600

  1600

20 00

 

200 0

1000

2500

 

 

  200 0

250 0

30 00

300 0

40 00

400 0

 

1Rating plug removal tool. Product Number TRTOOL,

150 200 150 200 225 250 300 400 300 400 450 500 600 700 800 400 600 800 1000 60 0 800 1000

TR2B150 TR2B20 0 TR4B150 TR4B20 0 TR4B225 TR4B250 TR4B30 0 TR4B40 0 TR8B30 0 TR8B40 0 TR8B450 TR8B50 0 TR8B60 0 TR8B70 0 TR8B80 0 TR10B400 TR10B600 TR10B800 TR10B100 0 TR16B60 0 TR16B80 0 TR16B1000

110 0 1200 1600 750 800 1000 1200 1500 1600 200 0 400 600 800 1000 750 800 1000 1200 1500 1600 200 0 1600

TR16B110 0 TR16B120 0 TR16B160 0 TR20B750 TR20B800 TR20B1000 TR20B1200 TR20B1500 TR20B1600 TR20B200 0 TR10B400 TR10B600 TR10B800 TR10B100 0 TR20B750 TR20B800 TR20B1000 TR20B1200 TR20B1500 TR20B1600 TR20B200 0 TR25B1600

200 0 250 0 1200 1600 200 0 250 0 300 0 1600 200 0 250 0 300 0 360 0 400 0

TR25B200 0 TR25B2500 TR30B1200 TR30B1600 TR30B200 0 TR30B2500 TR30B300 0 TR40B1600 TR40B200 0 TR40B2500 TR40B300 0 TR40B3600 TR40B400 0

$12.00, GO-135S .

Publications and Reference:  See Section 21 for a list of additional product-related publications  distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

     S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

5

www.geelectrical.com

Rev. 12/04 

BuyLog Catalog

5-45   Prices and data subject to change without notice 

 

Insulated Case Circuit Breakers 

Power Break I Circuit Breakers       S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

Neutral Current Sensors and POWER LEADER Accessories 

Neutral Current Sensors 1  Circui Circ uitt Bre Break aker er Sensor Rating (Amperes)

Breaker Frame (Amperes)

800

5

800-1600 1600

 

2000

3000

4000

GO-245B  Neutra Neut rall Sen Senso sor  r  Rating or Tap Settings (A (Amperes)

200

200

400 400 800 1000 1000 1600 1600 200 0 1000 1000 1000 1000 200 0 250 0 300 0 400 0

400/200 600/30 02 800/400 800/40 02 10 00/50 0 120 0/60 02 1600/100 0 2000/10 00 800/40 02 10 00/50 0 120 0/60 02 160 0/10002 2000/1200 2500/1800 30 00/2400 40 00/3000

Product   Number TSVG302 TSVG304A TSVG306A TSVG308A TSVG808A TSVG810A TSVG812A TSVG816A TSVG820A TSVG808A TSVG810A TSVG812A TSVG816A TSVG820A TSVG825A TSVG830A TSVG940A

List Pr Price    

$266.00                                

$266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00 $266.00

1Match neutral current sensor rating (or tap setting) to circuit breaker sensor rating. 2 For use with multiple source ground fault protection schemes. Rating does not match 

MicroVersaTrip MicroVersaT rip Plus or PM frame sensor.

MicroVersaTrip Portable Test Kit

GO-245B  

The test kit product number TVRMS2 is a portable, battery-powered, test kit which provides for trip unit health checks and functional trip  and no-trip tests. It also provides defeat of the ground-fault function  and can be used in conjunction with high-current test equipment. The test kit can be used to provide +24V power to the trip unit for  cold set-up and viewing of trip targets. This test kit is for use with  RMS-9, Epic, MicroVersaTrip Plus and MicroVersaTrip MicroVersaTrip PM trip units. The kit uses six rechargeable ni-cad or standard alkaline "D" cells  supplied by the customer. Kit can also be powered by 120 Vac  source. Description

Product Number

Portable Test Kit

TVRMS2

Neutral Current Sensor 

POWER LEADER Power Supplies

G0-104A

Power supply for furnishing 24Vdc control power for MicroVersaTrip  Plus and PM trip units. Two versions are available: a 4.0 ampere ver-  sion with AC and DC input voltages and a 0.8 ampere version capa-  ble of operating from 120/230 Vac. Both power supplies have inher-  ent transient protection circuits. System Requirements Description

(price separately)

4.0 ampere power supply Price one PLPS4G01 for each eac h lin line-up e-up.. 60 trip uni units ts and 100 ft. maxi maximum mum..

Input Inp ut pow power er,, 100V 100VA A (85-265Vac (85-265V ac or 100100-370V 370Vdc) dc)

Product   Number

List Price  

PLPS4G0 PLP S4G01 1   $1250.00

Reference  Instructions

GEH-5946

POWER LEADER Voltage Conditioner

G0-104A

List Price    

$3000.00

Conditions and scales 120 Vac to 1.76 Vac for use by the trip unit for 

MicroVersaTrip Portable Power Pack

GO-245B  

The handheld MicroVersaTrip portable battery pack provides an  independent power source for Enhanced MicroVersaTrip Plus and  MicroVersaTrip PM trip units as an alternative to the TVRMS2 test  set. The power pack is used to power up the trip unit to set or adjust  trip set points when the breaker is on the bench or otherwise not  powered up. It connects to the trip unit through the rating plug test   jack. It requires three (3) ( 3) standard 9Vdc alkaline batteries (not  included). Product number TVPBP List Price, $75.00, GO-245A. Description MicroVersaTrip Plus and PM Portable Power Pack

Product Number

List Price  

voltage sensing. Provides transient protection. Voltage conditioners  require isolation PTs PTs.. Description

System Re Requirements (price separately)

Supplies isolated bus voltage vol tage sig signal nal to MicroVersaTrip PM trip tr ip un unit its. s.

One set of 3 vol voltage tage con conditi ditioner oners s required for each voltage sensing loca lo cati tion on.. PT PTs s al also so re requ quir ired ed..

Rating Plug Removal Tool

 

$75.00

TRTOOL

List Price  

  $200.00 PLVC VC1G 1G01 01   per set

GO-135S  

Product Number TVPBP

Product   Number

List Price  

 

$12.00

distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

5-46

BuyLog Catalog

www.geelectrical.com  

Rev. 12/04 

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break I Circuit Breakers  Stationary and Draw-out Breaker Accessories 

A

D

C

All internally mounted accessories are UL Listed when field installed  (except where noted) in MicroVersaTrip breakers and MagneTrip  breakers with interchangeable trip units. These devices mount  within the breaker envelope envelope as shown to the right.

     S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

B

The control leads exist in pigtail form from the breaker side. These  leads are terminated at secondary disconnect points for draw-out  breakers or optional terminal blocks when specified for stationary  breakers. All leads are color coded.

Fig. 1. Accessory location  800, 1600 and 2000-ampere envelope sizes 

When ordered with draw-out circuit breaker a maximum of 48  secondary disconnects can be supplied (a maximum of 24 secondary  disconnects for standard 800-ampere draw-out 1). If the combination  of accessories and functions ordered per breaker require more than  the maximum secondary disconnects allowed, the breaker will be  wired according to standard manufacturing procedure; excess leads  will be left unwired (or customer can specify that all leads be left  unwired). See page 5-51 to determine the number of secondary  disconnects required for each device or function.

C

5

D

B

A

Refer to table below for accessory combinations, mounting positions  and lead exit information. Most accessories are available for field  installation and replacement by specifying the appropriate product  number. Instruction bulletins are included with each device.

Fig. 2. Accessory location. 3000 and 4000-ampere envelope sizes 

All electrically operated breakers include a shunt trip or undervolt-  age release for remote opening. Specify the electrical charging  voltage and trip device voltage separately. The price of the  electrical function will automatically automatically include the price of one shunt  trip or undervoltage release (UVR); specify desired device and  voltage with order. E

Fig. 3. Electrical operator location  All breakers 

Maximum Internal Accessories Available per Breaker  Mounting Position (See Figures Above)  A

Circuit Breaker Envelope Size (Amperes) 

Remote Close Solenoid, Remote Charge Indicator 

Shunt Trip 2 

UVR 

B  Blown Fuse Trip 

Shunt Trip 

Bell Alarm

C/D

E

Auxiliary Switch 

Electrical Operator 

Maximum Accessories Available Per Breaker Mounting Position (See Figures Above) 

800, 1600 and 2000

1

3000 and 4000

1

One of each



Any one

1 Any one

 

Accessory Lead Exit From Breaker 

123

4

5

12 3

4

5,6

1 800-ampere draw-out also available with up to 48 secondary disconnects. Refer to page 5-51. 2 For 3000 and 4000 ampere envelope size breakers the shunt trip will be located in position "B" (product number TSST—L, leads out left)

unless a bell alarm is also required. 3 Deduct two auxiliary switches per shunt trip device. Deduct one auxiliary switch for all MicroVersaTrip breaker frames with a "TTR" suffix, i.e. all

MicroVersaTrip PM and MicroVersaTrip Plus with provision for trip unit control power. 4 Electrically operated breakers require the addition of a shunt trip or UVR for remote opening. 5

All leads exit left side element except auxiliary switches. The remaining switch leads exit right. Leads for first six switch elements (4 when shunt trip is used) exit left. 6 Blown fuse trip, remote close solenoid, remote charge indication—leads exit right.

Publications and Reference:  See Section 21 for a list of additional product-related publications  distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

www.geelectrical.com

Rev. 12/04 

BuyLog Catalog

5-47   Prices and data subject to change without notice 

 

Insulated Case Circuit Breakers 

Power Break I Circuit Breakers       S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

Accessories  All devices UL Listed for factory or field installation installation except where where noted.

Remote Close Solenoid with Remote Charge Indication 1  for Manual Breakers (Factory Installed Only) Circuit Breaker Envelope Size (Amperes)

Control Voltage

GO-145A

Product   Number

List Price    

5

800, 1600, 20 00

30 00, 400 0

$658.00

120 Vac 240 Vac

TPXCC12S TPXCC14S

 

$658.00

24 Vac

TPXCC08S

 

$658.00

120 Vac

TSXCC12S

 

$658.00

240 Vac

TSXCC14S

 

$658.00

24 Vac

TSXCC08S

 

$658.00

1Replacement solenoid only. only. Order product number TPXEC** or TSXEC** (add voltage suffix: 12, 14 or 08). List Price 

$658.00, GO-148C. NOTE: Use of an OFF button actuated motor cut-off switch is recommended for electrically operated circuit breakers  wired for remote close. Order Product Number TAPD1, List Price $520.00, GO-145A.

Remo Re mote te Ch Char arge ge In Indi dica cati tion on fo forr Man Manua uall Br Brea eake kers rs (F (Fac acto tory ry In Inst stal alle led d Onl Only) y) Circuit Breaker Envelope Size (Amperes)

GO-1 GO -145 45A A

Product   Number

List Price

80 0, 160 0, 2000

TPXCAS

 

$488.00

3000, 40 00

TSXCAS

 

$488.00

Padlock On Button 2  for Manual Breakers (Factory Installed Only) Circuit Breaker Envelope Size (Amperes)

GO-145A

Product   Number

80 0, 160 0, 2000

TPXPL

3000, 40 00

TSXPL

 

List Price  

 

$111.00  

$96.50

2 Permits padlocking of the (local) breaker ON (close) button to prevent overriding the remote close function.

Shunt Trip

GO-145A

Shunt trip provides remote control tripping of the breaker. Integral cut-off switch automati-  cally de-energizes trip coil when breaker opens. It meets UL requirement for service on  ground fault systems. Field Installable Product Numbers 4 

Factory Installed Product Numbers 

Breaker Envelope Size (Amperes)  Coil Rating Vac

800, 1600 and 2000

2 500 , 3 00 0 and 4000 3  

800, 1600 and 2000

3 00 0   and 4000 3  

120, 240 480, 600

TPST12 TPST13

TSST12R, L TSST13R, L

TPST12S TPST13S

TSST12RS, LS TSST13RS, LS

   

$630.00 $630.00

12

TPST7

TSST7R, L

TPST7S

TSST7RS, LS

 

$630.00

24

TPST8

TSST8R, L

TPST8S

TSST8RS, LS

 

$630.00

48

TPST9

TSST9R, L

TPST9S

TSST9RS, LS

 

$630.00

125

TPST10

TSST10R, L

TPST10S

TSST10RS, LS

 

$630.00

250

TPST11

TSST11R, L

TPST11S

TSST11RS, LS

 

$630.00

List Price 

Coil Rating  Vdc 

3 R" (right) and "L" (left) refer to accessory mounting location. When shunt trip used with blown fuse detector or UVR 

specify "L". Use "R" with bell alarm. Normal lead exit is left side unless bell alarm is present. 4 To order a shunt trip for new installation on a breaker with an existing auxiliary switch contact your local GE Sales 

Office for information.

distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

5-48

BuyLog Catalog

www.geelectrical.com  

Rev. 12/04 

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break I Circuit Breakers  Accessories  All devices UL Listed for factory or field installation except where where noted.

UnderVoltage Release (UVR)

     S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

GO-145A

Automatically trips breaker when applied UVR coil voltage drops to 30-70% of rated value. Field Fie ld Inst Install allabl able e Prod Product uct Num Number bers s

Facto Fa ctory ry Ins Instal talled led Pro Produc ductt Numb Numbers  ers 

Breaker Envelope Size (Amperes)  Coil Rating Vac

800, 1600 and 2000

3 00 0 and 4000

800, 1600 and 2000

3000   and 4000

120 240 480 600

TPUV1 TPUV2 TPUV4 TPUV6

TSUV1 TSUV2 TSUV4 TSUV6

TPUV1S TPUV2S TPUV4S TPUV6S

TSUV1S TSUV2S TSUV4S TSUV6S

 

$630.00

 

$630.00

 

$630.00

 

$630.00

TPUV7 TPUV8 TPUV9 TPUV10 TPUV11

TSUV7 TSUV8 TSUV9 TSUV10 TSUV11

TPUV7S TPUV8S TPUV9S TPUV10S TPUV11S

TSUV7S TSUV8S TSUV9S TSUV10S TSUV11S

 

$630.00

 

$630.00

5

List Price  

Coil Rating  Vdc  12 24 48 125 250

 

$630.00  

$630.00

 

$630.00

Time Delay Module for UVR

GO-245B  

The time delay module prevents nuisance tripping due to momentary loss of voltage. The module has 120 Vac input and 125 Vdc output and must be used with the 125 Vdc UVR. Description

Product Number

Time Delay Module (0.1 to 1.0 second delay)

SPUVTD

List Price  

 

$430.00

Blown Fuse Trip (Three Coil Shunt Trip)

GO-145A

Provides single-phase protection for fuse and breaker combinations by automatically trip-  ping the breaker when a fuse blows. Suitable for system voltages of 120/208 to 600 Vac. Does  not protect when source single phases. Field Fie ld Inst Install allabl able e Prod Product uct Num Number bers s

Facto Fa ctory ry Ins Instal talled led Pro Produc ductt Numb Numbers  ers 

Breaker Envelope Size (Amperes)  System Voltage

800, 1600 and 2000

3 00 0 and 4000

800, 1600 and 2000

3000   and 4000

208 to 60 0 Vac

TPST316

TSST316

TPST316S

TSST316S

Bell Alarm with Lock-out

List Price    

$1530.00

GO-145A

Single-pole, double-throw (AB-type) switch element. Used for remote indication of breaker  trip when caused by overload, short circuit or ground fault conditions only. Switch element  ratings are identical to those listed for Auxiliary Switch Accessories. Bell alarm distinguishes  between overcurrent trip and manual/shunt/UVR trip. Factory Installed Product Numbers 1 Breaker Envelope Size (Amperes)  Breaker Type

800, 1600 and 2000

3 00 0   and 4000

MagneTrip Solid State

TPMBAS TPSBAS

TSBAAS TSSBAAS

1Not available for field installation except as replacement (delete S).

Publications and Reference:  See Section 21 for a list of additional product-related publications 

List Price  

$259.00

 

$259.00

 

distributed by AA Electric Electric 1 800 237 8274 www.a aelectric.com

www.geelectrical.com

Rev. 12/04 

BuyLog Catalog

5-49   Prices and data subject to change without notice 

 

Insulated Case Circuit Breakers 

Power Break I Circuit Breakers       S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

5

Accessories  All devices UL Listed for factory or field installation except where noted.

Auxiliary Switch  Single-pole, double-throw (AB-type) switch elements. Used for remote indication of breaker  main contact position (on/closed or off/opened). Switch 600 Vac.element ratings: 1/4 ampere at 250 Vdc; 1/2 ampere at 125 Vdc; 6 amperes at 240 or  Refer to page 5-47 footnote (3) for limits on maximum number in combination with other  accessories.

240 Vac, 125 Vdc  Field Fie ld Ins Instal tallab lable le Pro Produc ductt Numb Numbers ers

Facto Fa ctory ry Inst Install alled ed Pro Produc ductt Numb Numbers  ers 

Breaker Envelope Size (Amperes)  No. of SPDT  SPDT  Switch Elements (Contacts)

800, 1600 and 2000 1 

30 0 0 and 4000 2 

800, 1600 and 2000

3000 and 4000

1 2 3 4 5 6 7 8

TPAS2AB1 TPAS2AB2 TPAS2AB3 TPAS2AB4 TPAS2AB5 TPAS2AB6 – –

TSAS2AB1 TSAS2AB2 TSAS2AB3 TSAS2AB4 TSAS2AB5 TSAS2AB6 – –

TPAS2AB1S TPAS2AB2S TPAS2AB3S TPAS2AB4S TPAS2AB5S TPAS2AB6S TPAS2AB7S TPAS2AB8S

TSAS2AB1S TSAS2AB2S TSAS2AB3S TSAS2AB4S TSAS2AB5S TSAS2AB6S TSAS2AB7S TSAS2AB8S

 

$1180.00

9 10 11 12

– – – –

– – – –

TPAS2AB9S TPAS2AB10S TPAS2AB11S3 TPAS2AB12S3

TSAS2AB9S   TSAS2AB10S   3 TPAS2AB11S TPAS2AB12S3

$1215.00 $1240.00

List Price   GO-145A  

$251.00

 

$503.00

 

$534.00

 

$562.00

 

$623.00

 

$680.00

 

$924.00

$1300.00 $1365.00

600 Vac, Not UL Listed  Field Fie ld Ins Instal tallab lable le Pro Produc ductt Numb Numbers ers

Facto Fa ctory ry Inst Install alled ed Pro Produc ductt Numb Numbers  ers 

Breaker Envelope Size (Amperes)  No. of SPDT  SPDT  Switch Elements (Contacts)

800, 1600 and 2000 1 

30 0 0 and 4000 1

800, 1600 and 2000

3000 and 4000

1 2 3 4 5 6 7 8 9

TPAS6AB1 TPAS6AB2 TPAS6AB3 TPAS6AB4 TPAS6AB5 TPAS6AB6 – – –

TSAS6AB1 TSAS6AB2 TSAS6AB3 TSAS6AB4 TSAS6AB5 TSAS6AB6 – – –

TPAS6AB1S TPAS6AB2S TPAS6AB3S TPAS6AB4S TPAS6AB5S TPAS6AB6S TPAS6AB7S TPAS6AB8S TPAS6AB9S

TSAS6AB1S TSAS6AB2S TSAS6AB3S TSAS6AB4S TSAS6AB5S TSAS6AB6S TSAS6AB7S TSAS6AB8S TSAS6AB9S

10 11 124

– – –

– – –

TPAS6AB10S3 TPAS6AB11S TPAS6AB12S3

List Price   GO-145A  

$251.00

 

$503.00

 

$534.00

 

$562.00

 

$623.00

 

$680.00

 

$924.00

 

$1180.00

 

$1215.00

TSAS6AB10S3   TPAS6AB11S TSAS6AB12S3

$1240.00 $1300.00 $1365.00

1Mounts in right pole only when shunt trip specified. 2 Field installed auxiliary switches and shunt trips must mount on opposing poles only. 3 Not available on breakers equipped with a shunt trip. 4 Not available on MicroVersaTrip PM breakers or breakers equipped with MicroVersaTrip Plus and provisions for 

trip unit control power. power.

distributed by AA Electric Electric 1 800 237 8274 www.a aelectric.com

5-50

BuyLog Catalog

www.geelectrical.com  

Rev. 12/04 

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break I Circuit Breakers  Draw-Out Breakers Accessories  OEM Substructures

GO-145A

Allows a maximum of 48 secondary disconnects (except where noted); required for trip units and breaker control functions. Product Number Standard Break Frame Rating (Amperes)

Max. Am Ampere   Rating

Manual

Electric

8001

80 0

TDOS08

TDOS08E

Product Number   Hi-Break 1  

   

1860000 2000 250 0 250 0 3000 4000

1860000 200 0 200 0 250 0 300 0 400 0

T 8L TD DO OS S0 16 TDOS20 TDOS25 TDOS25 TDOS30 TDOS40

T LE TD DO OS S0 18 6E TDOS20E TDOS25E TDOS25E TDOS30E TDOS40E

Number of Secondary Disconnect Circuits Required per Auxiliary Device 2 

 

List Price

Manual

$1545.00

THDOS08

Electric

List Price    

THDOS08E

$2990.00

 

$2990.00

 

$4355.00

 

$4715.00

 

$4715.00

 

$6300.00 $15910.00

T TH HD DO OS S0 18 6L THDOS20 THDOS25 THDOS25 THDOS30 THDOS40

T 8L TH HD DO OS S0 16 EE THDOS20E THDOS25E THDOS25E THDOS30E THDOS40E

 

Required Number  

Neutral Sensor Leads (MicroVersaTrip only) Electrical Operation Auxiliary Switch per Element Undervoltage Release Bell Alarm Shunt Trip Blown Fuse Trip Remote Close Solenoid and Charge indication Remote Charge indication

2 6 3 2 3 2 6 3 2

Secondary Di Disconnects fo for Dr Draw-out Br Breakers Field installation kits; 48 circuits maximum per draw-out. (24 maximum for standard 800 ampere draw-out). Description

Product Number TDOS D6 D6S3 TDOSD6B

 

$4695.00

 

$5080.00

 

$5080.00 $6790.00 $17150.00

GO-245B  

Provides positive indication that the draw-out breaker or switch  primary contact fingers are fully connected to the main bus in the  substructure. Switch contacts change states only after the primary  fingers are fully connected when the breaker is being moved from  the DISCONNECTED position through the TEST position and into the  CONNECTED position.

visual position indicator on the draw-out substructure. The By-pass  switch accessory does not indicate either the TEST or DISCONNECTED  position. The switch assembly mounts on the stationary frame and  the actuator mounts to the carriage. Switch contacts are rated at  10A at 600 Vac, 0.75A at 125 Vdc, and 0.25A at 250 Vdc. Description

List Price   $320.00  

$3230.00

May be used to provide control circuit continuity or downstream  signaling that the draw-out breaker is connected in addition to the 

GO-145A

Subst ru ruct ur ure Di sc sconnect Kit 6 Ci rc rcuit s Breaker Disconnect Kit 6 Circuits Substructure Disconnect with Zone Interlocking Z1 or Z2 Suffix Substructure Disconnect for 24V dc dc Trip Un Unit Co Control Po Power On Only Substructure Disconnect for MicroVersaTrip PM Functions and Zone Sel ec ect iv iv e Int er er lo locking (Z1 /Z /Z2 )

$3230.00

 

 

Bypass Switch

Device/Function

$1670.00  

$278.00

Product Number

List Price  

Bypass Switch for 800 through 4000 Amperes: 2 Elements TDOBP2L 4 Elements TDOBP4L 6 Elements TDOBP6L

 

$177.00

 

$256.00

 

$336.00

TDOSVD04

 

$144.00

Position Switch

TDOSVD02

 

$166.00

TDOSVD12

 

$166.00

Provides positive indication when the draw-out breaker or switch  primary contact fingers have been fully withdrawn from the main bus  connections. Switch contacts change state only after the primary  fingers are fully disconnected when the breaker is being moved from 

GO-245B  

the CONNECTED position. position through the TEST position and into the  DISCONNECTED

Draw-Out Accessories Description Mechanical In Interlock, Horizontal Interconnect Mechanical In Interlock, Vertical In Interconnect Shutters

Padlock Device Lifting Bar Racking Tool

GO-145A Frame Rating (Amperes)

Product   Number

800-200 0 250 0-40 00 800-200 0 250 0-4000 800 1600-200 0 250 0-3000 4000 All All All

TDOWB1 TDOWB2 TDOWB3 TDOWB4 TDOSS08 TDOSS20 TDOSS30 TDOSS40 TDOPC TDOLB4 TDORT4

List Price    

$712.00

 

$712.00

 

$712.00

 

$712.00

 

$1155.00

 

$1155.00

 

$1155.00

 

$1155.00

 

May be used as part of a safety interlocking system in addition to  the visual indicator indicator on the draw-out substructure. substructure. The Position  Switch accessory does not indicate either the TEST or CONNECTED  position. The switch assembly mounts on the stationary frame and  the actuator mounts to the carriage. Switch contacts are rated at  10A at 600 Vac, 0.75A at 125 Vdc, and 0.25A at 250 Vdc.

$46.005 $104.00 5 $70.005

Number of Switch Elements

Product Number

2 NO/2 NC 4 NO/4 NC 6 NO/6 NC

SDOPS2L SDOPS4L SDOPS6L

List Price    

$177.00

 

$256.00

 

$336.00

1Allows up to 24 secondary disconnects. See table below to determine number of secondary disconnects required. 2 Breaker accessories ordered for field installation require a corresponding set of breaker mounted secondary disconnects. Refer to table above for quantity. 3 Secondary disconnects for substructure portion must be ordered and priced separately. For factory installation, so specify. 4 One lifting bar and one racking tool supplied with every five draw-out breakers at no charge. 5 GO-245B 

NOTE: Breaker portion of secondary disconnects supplied at no charge when accessories are ordered with breaker. MicroVersaTrip MicroVersaTrip draw out breakers are provided as standard  with secondary disconnect positions positions for possible neutral current sensor leads.

Publications and Reference:  See Section 21 for a list of additional product-related publications 

     S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

5

distributed by AA Electric Electric 1 800 237 8274 www.a aelectric.com

www.geelectrical.com

Rev. 12/04 

BuyLog Catalog

5-51   Prices and data subject to change without notice 

 

Insulated Case Circuit Breakers 

Power Break I Circuit Breakers       S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

Accessories  All devices UL Listed for factory or field installation installation except where where noted.

Terminal Block (Factory Installed Only)

GO-145A

Offers an external means of terminating accessory leads at the breaker. A maximum of 18  terminals can be supplied on each side of the breaker (36 terminals total). For stationary  breakers only. Terminal blocks are rated 10 amperes at 600 Vac. Factory Installed Product Numbers 

5

Breaker Envelope Size (Amperes)  Terminals

800, 1600 and 2000 1  

30 0 0   and 4000

6 12 18 24 30 36

TPTB1R, L TPTB2R, L TPTB3R, L TPTB4L TPTB5L TPTB6L

TSTB1R, L TSTB2R, L TSTB3R, L – – –

List Price    

$158.00

 

$221.00

 

$286.00

 

$444.00

 

$508.00

 

$573.00

1Left side only on frames with MicroVersaTrip MicroVersaTrip trip units.

Kirk Key Provision

GO-145A

Permits sequencing of breaker operations with other key-type devices. The key remains  captured in frame except when the breaker has been locked in the OPEN position. The Kirk  Key provision must be factory installed on 3000 and 4000 ampere envelope sizes. Customer to  provide Kirk Key lock device(s). (Key removable when bolt extended).

800, 160 0 and 20003 30 00 and 4000

Trip Device

Maximum Number of Locks 1 2 3 4 6 6

MicroVersaTrip or MagneTrip MagneTrip4 MicroVersaTrip

Factory Installed TPK01 TPK02 TPK03 TPK04 TSK16 TSK26

List Price  

$817.00

 

$817.00

 

$817.00

 

$817.00

 

$817.00

 

$817.00

Field Installed 2   TPK01F TPK02F TPK03F TPK04F – –

TPK01, TPK01B TPK02 TPK03 TPK04

Type F Type M2F Type M3F Type M4F

One-inch Bolt Protection 

Note: Any breaker installed with Kirk Key provision must be replaced with a similarly  provisioned breaker. Circuit Breaker Envelope Size (Amperes)

Zero Bolt Protection 

TSK16, TSK26

List Price   

$773.00

 

$773.00

 

$773.00

 

$773.00

Type F Type M2F Type M3F Type M4F Type M5F Type M6F

– –

2 Cannot be assembled on a breaker with padlock type TSPL or TSPDL. 3 UL Listed for factory or field installation. 4 Includes molded case switch.

Door Interlock and Padlock GO-145A Door interlock and padlock prevents opening enclosure door when breaker is closed. Available for stationary or draw-out construction. Supplied with breaker padlock suitable for use with three locks (locks supplied by purchaser). Padlock enables breaker to be locked in an  open position with up to three (3) padlocks—meets California code. Padlocks supplied by purchaser. Product Number  Padlock and Defeatable Door Interlock 6  Circuit Breaker  Envelope Size (Amperes) 800, 1600, 20 00 30 00 00, 400 0 30 00, 400 0 30 00 00, 400 0

Padlock and Non-defeatable   Door Interlock 

Breaker Operation

Trip Device

Standard Break

List Price

Hi-Break

List Price

Standard Break

Manual or Electrical Manual or Electrical7 Manual Electrical7

MicroVersaTrip or Magne Trip

TSPDL8

$398.00

TSPDL8

$398.00

TSPL8,9

$106.00

TSPL8,9

$106.00

MicroVersaTrip MagneTrip MagneTrip

TPSSDIPL TPSDIPL TPSEDIPL

$398.00

THSSDIPL   THSDIPL   THSEDIPL  

$398.00

TPSSLDA10 TPSLDA10 TPSLDEA10

$103.00

THSSLDA10 THSLDA10 THSLDEA10

$109.00

   

$423.00  

$423.00

$398.00 $398.00

  List Price

$106.00 $106.00

Hi-Break

List Price  

$98.50 $114.00

6 Door interlock is defeatable with a small tool to allow authorized access. 7 OFF button actuated motor cut-off switch for electrically operated 3000 and 4000 ampere envelopes is available. Order Product Number TAPD1, List Price $520.00, GO-145A. 8 

available for breakers supplied with Kirk Key provision. Factory installed only. 9 Not Padlock and non-defeatable door interlock. 10 Padlock only.

distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

5-52

BuyLog Catalog

www.geelectrical.com  

Rev. 12/04 

Prices and data subject to change without notice   

Insulated Case Circuit Breakers 

Power Break I Circuit Breakers  Accessories  All devices UL Listed Listed for factory or field installation except where noted.

     S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

Walking Walk ing Beam Interlock Interlock for for Stationary Stationary Breakers—No Breakers—Nott UL Listed GO-145 GO-145A A Circuit Breaker Envelope Size (Amperes)

Product   Number

800, 1600, 200 0 300 0

List Price  

TPWB TSWB

 

$525.00

 

$569.00

Contact GE Sales office for availability of walking beam for 4000A frame.

Adapter Kits

GO-245B

 

5

Premounts to bus structure allowing cabling or bussing to be completed prior to breaker  mounting. Accepts either lugs or crimp type connector terminals. Product number includes  adapter and hardware for three-pole line side, or three-pole load side connection connection.. Circuit Breaker  Envelope Size (Amperes) 80 0 160 0

Suitable for   use with up to:

Product Number

3 TPLUG108 Lugs or 3 Crimp Lugs1 pe r Pole 6 TPLUG108 Lugs or 6 Crimp Lugs1 pe r Pole 6 TPLUG108 Lugs or 6 Crimp Lugs1 pe r Pole

List Price    

TPL UG UG A0 A0 8

$78.50

TPL UG UG A1 A162

20 00 00 1Anderson No. VCEL-075-12H1 or equivalent 

TPL UG UG A2 A2 0

800A Power Break with TPLUGA08 adapter and 9  TPLUG108 lugs 

1600A Power Break with TPLUGA16 adapter and 6  TPLUG108 lugs 

Type PLUG206 

Type TPLUG308 

Type TPLUG408 

Type TSLUG20 

Typ e T P 0 8 F C A

Typ e T P 1 6 FC A

$389.00  

$487.00

2 T-studs—TP16FCA T-studs—TP16FCA—included —included with adapter 

Lug Kits

GO-245B

 

Kits accept Cu/AI wire and are suitable for direct mounting to the breaker. When order-  ing Type TPLUG kits, order one kit per line or load pole. Example: A complete set of lugs  for the line side of an 800A frame, 400A trip breaker would be Qty 3-TPLUG106 lugs. When ordering TSLUG kits order one kit per line or load side; TSLUG kits require use of  T-studs. Example: A complete set of lugs for a 3000A frame, 2500A trip breaker would be  Qty 1-TSLUG25. T-Studs would also be required. Circuit Breaker Frame Si S ize Max. Ra Rating (Amperes) (Amperes) 800 800 800 800 1600 1600 20 00 30 00 30 00 30 00 30 00 30 00 30 00 40 00

40 0 60 0 80 0 80 0 160 0 160 0 200 0 80 0 120 0 160 0 200 0 2500 300 0 400 0

Product Number

Lugs Per Ki Kit

Max. Cables Per Po Pole

Wire   Range   kcmil Cu Cu/AI List Pr Price  

1 1 1 1 1 1 1 9 12 15 18 21 27 33

1 2 3 3 6 4 6 3 4 5 6 7 9 11

(1) #2-60 0   $18.50 (1) #2-60 0   $27.50 (3) 30 0-750   $32.00 3/0-800   $23.00 3/0-800   $23.00 500-800   $39.00 3/0-800   $23.00 3/0-800   $274.00 3/0-800   $296.00 3/0-800   $345.00 3/0-800   $383.00 3/0-800   $418.00 3/0-800   $630.00 3/0-800   $1045.00

TPLUG106 TPLUG206 TPLUG308 TPLUG1083 TPLUG1083 TPLUG408 TPLUG1083 TSLUG08 TSLUG12 TSLUG16 TSLUG20 TSLUG25 TSLUG30 TSLUG40

3 For use with adapter kit only. See table above.

T-Studs

GO-145A

Studs mount to breaker or adapter kit. All 800-3000 ampere studs studs can be rotated for  either vertical or horizontal bus connection. 4000 ampere studs are vertical bus only. Product number includes one stud. Circuit Breaker Envelope Size (Amperes)

Max Rating (Amperes)

800 1600 20005 30 00 30 00 30 00 40 00 40 00

80 0 160 0 200 0 200 0 2500 300 0 400 0 400 0

Front Connected Breaker Product Number TP08FCA4 TP16FCA4 TP20FCA4 TS20FCA4 TS25FCA6 TS30FCA7 TS40FCA7 TS40LFCA7,9

Back   Connected Breaker Product Number

TS20BCA4,6 TS25BCA6 7,8

4 Aluminum  5 Small envelope

2000-ampere Power Break  6 Six T-studs supplied at no charge when ordered with breaker. 7 Copper  8 Supplied with integral "T" stud  9 Extra long stud. Alternate with TS40FCA to maintain proper spacing.

Publications and Reference:  See Section 21 for a list of additional product-related publications 

List   Price   $82.00 $113.00 $113.00 $113.00 $119.00 $418.00 $562.00 $789.00

distributed by AA Electric Electric 1-800-237-8274 www.a-aelectric.com

www.geelectrical.com

Rev. 12/04 

BuyLog Catalog

5-53   Prices and data subject to change without notice 

 

Insulated Case Circuit Breakers 

Power Break I Circuit Breakers       S      E     R      S     E      A     K      C     A      E      D     R      E     B      T     T      A     I      L     U      U     C      S     R      I      N      I      C

5

Enclosures 

General Purpose Wall and Floor Mounted Enclosures  —800 and 1600 ampere enclosures are UL Listed for service  entrance use for single-phase, three-wire or three-phase, four-wire, 600 Vac maximum systems. —NEMA 1 construction. —Enclosures for 800- and 1600-ampere envelope sizes are supplied  with studs that support circuit breaker in correct position for easy  mounting. Enclosure, circuit breaker, and neutral must be ordered  separately and are shipped unassembled. —Enclosures for floor mounted 3000-ampere envelope size are  shipped with circuit breaker and neutral already installed. Enclosure and circuit breaker must be ordered separately. TPB800 

—Enclosure product number includes lugs. —Suitable for use on 65 kA (max) rms symmetrical systems. —Aluminum bus straps and mechanical lugs are included on floor  mounted enclosures.

Power Break Enclosures  Circuit Breaker Max. Envelope Size Ampere (Amp (A mper eres es)) Rati Ra ting ng

Enclosure Product Number 1 (Includes Lugs)  Magn Ma gneT eTri rip p

List Price, Micr Mi croV oVer ersa saT Tri rip  p 2  GO -1 -1 34 34

Field  Installed Neutral Product N um um be ber

  List   Price, GO -1 -1 49 49  

Wall Mounted  80 0 1600

80 0 160 0

 

$5137.00   TNT800   $384.00 $5334.00   TNT1600   $437.00

– TPB160 0

TPB800 TPB1600

TS160 0N TS20 00N TS2500N

TSS160 0N   $8117.00 TSS2000N   $8617.00 TSS2500N   $10576.00

 

Floor Mounted 3,4  300 0 300 0 300 0

160 0 200 0 2500

     

– – –

– – –

1Add "E" suffix for motor operated breakers.

8 0 0A E n v e l o p e

2 0 0 0A E n v e l o p e  

30 0 0 A E n ve l o p e

4 0 0 0A E n v e l o p e  

2 For single-phase, 3-wire or 3-phase, 4-wire systems with internal ground fault 

protection, appropriate neutral CT must be ordered with circuit breaker from page 5-46. 3 Enclosure may be floor or wall mounted. 4 Order by product number on standard order entry form DE-135, including any factory-installed breaker accessories. Fax order to Plainville Assembly Center at (860) 747-7032. Enclosure outline drawing is 75C325345SH1.

FAS Team  Your source for factory authorized repair and modernization services  for Power Break. Look to us for:  —Genuine GE factory parts  —Accessory installations  —Direct factory replacement breakers  —Test —T est certification  cert ification  —Rentals and loaners  Repairs are performed by GE’s Factory Authorized Service Team, and 24-hour emergency service is available. For service on your Power Break breakers, contact your local sales  office, or visit us at www.gepower www.gepower.com  .com 