Plano de Retenida

March 28, 2023 | Author: Anonymous | Category: N/A
Share Embed Donate


Short Description

Download Plano de Retenida...

Description

 

LISTA DE MATERIALES PARA RETENIDAS DE CONDUCTORES DE FASE ITEM

CANT.

UNIDAD

7.1

1

u

7.5

1

u

8.5

1

u

ARANDELACUADRADA4"x4"x3/8" (102x102x9.5mm) CONAGUJERO ø11/16" (ø17.8mm)

1

u

CONTRAPUNTADE 51mmø x1200 mm PARADOS RETENIDAS

15.1

1

u

15.2

1

u

20.1

V ARI ABLE

m

CABLE ALUMOWELDø11.1 mm, CARGADEROTURA95 KN

u

PREFORMADODEA°G°, CARGADE ROTURA100KN

u

ALAMBRE DE A°G° N°12 PARAENTORCHADO, 2.5 m

22.2

-

4" MAQUINADO

YUGODE A°G° DE 70 KNTIROROTURA

11.1

22.1

 A

DESCRIPCION

VARILLADE ANCLAJE CONOJALGUARDACABOø3/4"x8" LONGITUD(ø16X2400mm), (101.6mm) CONT/CT, CARGADE ROTURA100KN

27.1

4

u

28.3

2

u

ABRAZADERA(T1) DE 3/8" x4" TIPO 45 VIAS 90° CONPERNOS AJUSTE, ø DELPOSTE 7"-10" (178mm-254mm), CARGADEROTURA55kN

ABRAZADERA(T2) DE 3/8" x4" TIPO 45 VIAS 90° CONPERNOS AJUSTE, ø DELPOSTE 7"-10" (178mm-254mm), CARGADEROTURA65kN

GUARDACABOHORQUILLA, PERNOø11/16" (18mm), ABERTURA22mm, CARGADE ROTURA70KN

CONECTOR DE ACOPLAMIENTO1/4" x3" x 9 1/2" CONAGUJEROS ø 15/16" (24mm), ABERTURA1 1/2"(38.1mm), CARGADE ROTURA70KN

36.1

1

u

BLOQUEDE CONCRETO, CONAGUJEROø1" (ø25.4mm)

35.2

1

u

PROTECTOR DERETENIDA DEACERO, MEDIAREDONDA CONGAN CHOSUPERIOR Y GRAPAINFERIOR, 8' LONGITUD (2438.4mm)

43

1

u

AISLADOR POLIMERICOTIPO SUSPENSIÓNCONTERMINALES CLEVES DE36 KV,100 KN.

ALTURA DE INSTALACION Y LONGITUD DELCABLE DE RETENIDA

DE LOS

CONDUCTORES DE FASE

TIPODE ESTRUCTURA

LONGITUDDE POSTEDE MADERA(ft)

ALTURADE INSTALACION LONGITUDTOTALDELCABLE DE LARETENIDAENEL ALUMOWELD(m) POSTE H(m)

50'

12.19

17.23

55'

13. 61

19. 24

50'

11.74

16. 60

55'

13.16

18.61

50'

12.04

17.02

55'

13.46

19.03

MA2

B MA3

MA5

ALTURA DE INSTALACION Y LONGITUD DEL CABLE DE RETENIDA

TIPODE ESTRUCTURA

LONGITUDDEPOSTE DE MADERA(ft)

PARA EL CABLE OPGW

ALTURADE INSTALACION LONGITUDTOTALDELCABLE DE LARETENIDAENEL ALUMOWELD(m) POSTE H(m)

50'

12. 79

55'

14.21

18.08 20.09

50'

12. 49

17.66

MA2

MA3 55'

13.91

19. 67

50'

12. 64

17. 87

55'

14. 06

19.88

MA5

RELLENO COMPACTADO

NOTAS: 1. 2. 3.  

RETENIDA TIPO R2 SERÁ UITILIZADA EN LA LÍNEA 22.9kV CON CABLE AUTOSOPORTADO. LA ABRAZADERA T1, SERÁ USADA PARA CONTENER LAS CARGAS GENERADAS POR EL OPGW. LA ABRAZADERA T2, SERÁ USADA PARA CONTENER LAS CARGAS GENERADAS POR EL CONDUCTOR AUTOSOPORTADO.

 ABENGOA 