PDS Piping Eden Interface

February 23, 2018 | Author: balajivangaru | Category: Library (Computing), License, Subroutine, Specification (Technical Standard), Modular Programming
Share Embed Donate


Short Description

erwe...

Description

Plant Design System (PDS) Piping Eden Interface

Version 2011 (V12) May 2011 DPDS3-PB-200013G

Copyright Copyright © 1984-2011 Intergraph Corporation. All Rights Reserved. Including software, file formats, and audiovisual displays; may be used pursuant to applicable software license agreement; contains confidential and proprietary information of Intergraph and/or third parties which is protected by copyright law, trade secret law, and international treaty, and may not be provided or otherwise made available without proper authorization from Intergraph Corporation.

U.S. Government Restricted Rights Legend Use, duplication, or disclosure by the government is subject to restrictions as set forth below. For civilian agencies: This was developed at private expense and is "restricted computer software" submitted with restricted rights in accordance with subparagraphs (a) through (d) of the Commercial Computer Software - Restricted Rights clause at 52.227-19 of the Federal Acquisition Regulations ("FAR") and its successors, and is unpublished and all rights are reserved under the copyright laws of the United States. For units of the Department of Defense ("DoD"): This is "commercial computer software" as defined at DFARS 252.227-7014 and the rights of the Government are as specified at DFARS 227.7202-3. Unpublished - rights reserved under the copyright laws of the United States. Intergraph Corporation P.O. Box 240000 Huntsville, AL 35813

Terms of Use Use of this software product is subject to the End User License Agreement ("EULA") delivered with this software product unless the licensee has a valid signed license for this software product with Intergraph Corporation. If the licensee has a valid signed license for this software product with Intergraph Corporation, the valid signed license shall take precedence and govern the use of this software product. Subject to the terms contained within the applicable license agreement, Intergraph Corporation gives licensee permission to print a reasonable number of copies of the documentation as defined in the applicable license agreement and delivered with the software product for licensee's internal, non-commercial use. The documentation may not be printed for resale or redistribution.

Warranties and Liabilities All warranties given by Intergraph Corporation about equipment or software are set forth in the EULA provided with the software or applicable license for the software product signed by Intergraph Corporation, and nothing stated in, or implied by, this document or its contents shall be considered or deemed a modification or amendment of such warranties. Intergraph believes the information in this publication is accurate as of its publication date. The information and the software discussed in this document are subject to change without notice and are subject to applicable technical product descriptions. Intergraph Corporation is not responsible for any error that may appear in this document. The software discussed in this document is furnished under a license and may be used or copied only in accordance with the terms of this license. No responsibility is assumed by Intergraph for the use or reliability of software on equipment that is not supplied by Intergraph or its affiliated companies. THE USER OF THE SOFTWARE IS EXPECTED TO MAKE THE FINAL EVALUATION AS TO THE USEFULNESS OF THE SOFTWARE IN HIS OWN ENVIRONMENT. Intergraph is not responsible for the accuracy of delivered data including, but not limited to, catalog, reference and symbol data. Users should verify for themselves that the data is accurate and suitable for their project work.

Trademarks Intergraph, the Intergraph logo, PDS, SmartPlant, FrameWorks, I-Convert, I-Export, I-Sketch, SmartMarine, IntelliShip, INtools, ISOGEN, MARIAN, SmartSketch, SPOOLGEN, SupportManager, and SupportModeler are trademarks or registered trademarks of Intergraph Corporation or its subsidiaries in the United States and other countries. Microsoft and Windows are registered trademarks of Microsoft Corporation. Oracle, JD Edwards, PeopleSoft, and Retek are registered trademarks of Oracle Corporation and/or its affiliates. MicroStation is a registered trademark of Bentley Systems Inc, all rights reserved. Other brands and product names are trademarks of their respective owners.

Contents Preface PDS ................................................................................................................................................. 5 What's New in Piping Eden Interface ........................................................................................................ 6 The Eden Basics .......................................................................................................................................... 7 Graphic Commodity Data ........................................................................................................................ 8 Graphic Commodity Library .................................................................................................................... 8 Physical Data Tables ............................................................................................................................ 10 Data Retrieval from the Physical Data Library ............................................................................... 11 Example of Physical Data Look-Up ................................................................................................ 11 Component Placement Example .............................................................................................................. 13 Eden Modules ....................................................................................................................................... 13 Symbol Processors ......................................................................................................................... 15 Sub-Symbol Processor ................................................................................................................... 16 Physical Data Definitions ................................................................................................................ 17 Parametric Shape Definitions ......................................................................................................... 23 Forms Interface ..................................................................................................................................... 26 Notes for Graphic Commodity Data ...................................................................................................... 26 Connect Point Data ........................................................................................................................ 26 Bends and Branches ...................................................................................................................... 28 Bolts, Gaskets, and Flanges .......................................................................................................... 28 Pipe, Tubing, and Hose .................................................................................................................. 29 Eden Language Structure ......................................................................................................................... 31 Beginning Statements ........................................................................................................................... 31 Ending Statements ................................................................................................................................ 32 Variables ............................................................................................................................................... 32 Local Variables ............................................................................................................................... 32 Global Variables Common to Piping, Equipment, and Pipe Support Modeling ............................. 34 Piping Eden Global Variables ......................................................................................................... 35 Common Keywords ............................................................................................................................... 38 Keywords (Piping Specific) ............................................................................................................. 38 Comments ............................................................................................................................................. 41 Operators .............................................................................................................................................. 41 Arithmetic Operators ....................................................................................................................... 41 Relational Operators ....................................................................................................................... 42 Logical Operators ........................................................................................................................... 42 Expressions ........................................................................................................................................... 43 Replacement Statements ............................................................................................................... 43 Call Statement ................................................................................................................................ 43 Do While Statement........................................................................................................................ 43 Indexed Do Statement .................................................................................................................... 44 If - then - else Statement ................................................................................................................ 44 Functions ............................................................................................................................................... 45 Primitives ............................................................................................................................................... 46 Convert NPD to Subunits ............................................................................................................... 46

Plant Design System (PDS) Piping Eden Interface

3

Contents Define Active Orientation ................................................................................................................ 47 Draw Cone ...................................................................................................................................... 48 Draw Cylinder ................................................................................................................................. 49 Draw Eccentric Cone ...................................................................................................................... 49 Draw Projected Rectangle .............................................................................................................. 50 Draw Projected Triangle ................................................................................................................. 51 Draw Semi-Ellipsoid ....................................................................................................................... 51 Draw Sphere ................................................................................................................................... 52 Draw Torus ..................................................................................................................................... 53 Assign Connect Point ..................................................................................................................... 53 Assign Generic Tap ........................................................................................................................ 54 Assign Tap ...................................................................................................................................... 54 Compute Perpendicular Vector ...................................................................................................... 55 Define Connect Point Geometry ..................................................................................................... 55 Display Tutorial ............................................................................................................................... 56 Draw Cone With Capped Ends ...................................................................................................... 57 Draw Cylinder With Capped Ends .................................................................................................. 57 Draw Eccentric Cone With Capped Ends....................................................................................... 58 Draw Hexagon ................................................................................................................................ 59 Draw Mitered Torus ........................................................................................................................ 59 Draw Octagon ................................................................................................................................. 60 Draw Parametric Shape ................................................................................................................. 61 Draw Torus with Capped Ends ....................................................................................................... 61 Get Physical Data ........................................................................................................................... 62 Move Along Axis ............................................................................................................................. 63 Move By Distance ........................................................................................................................... 63 Move To Connect Point .................................................................................................................. 64 Place COG Location ....................................................................................................................... 64 Place Connect Point ....................................................................................................................... 65 Prompt to Orient Operator .............................................................................................................. 65 Read Table ..................................................................................................................................... 65 Rotate Orientation .......................................................................................................................... 66 Connect Point Geometry....................................................................................................................... 67 Creating a New Piping Component ......................................................................................................... 73 Reference Database Management Data .............................................................................................. 75 Default Project Control Data ................................................................................................................. 79 Extracting Sample Modules .................................................................................................................. 80 Editing Modules..................................................................................................................................... 81 Compiling New Modules ....................................................................................................................... 82 Revising Modules .................................................................................................................................. 82 Basic Use of Forms ............................................................................................................................... 83 Piping Specialty Components ............................................................................................................... 84 Appendix: EDEN Error Messages .......................................................................................................... 101 Index ......................................................................................................................................................... 105

4

Plant Design System (PDS) Piping Eden Interface

Preface PDS This document provides command reference information and procedural instructions for the Plant Design System (PDS) Piping Eden Interface taks.

List of PDS Documentation                             

DPDS3-PB-200003 - DesignReview Integrator (PD_Review) Reference Guide DPDS3-PB-200004 - Drawing Manager (PD_Draw) User's Guide DPDS3-PB-200005 - EE Raceway Modeling Reference Guide DPDS3-PB-200006 - Interference Checker/Manager (PD_Clash) User's Guide DPDS3-PB-200010 - PDS 3D Theory User's Guide DPDS3-PB-200013 - PDS EDEN Interface Reference Guide Volume I : Piping DPDS3-PB-200015 - PDS Equipment Modeling (PD_EQP) User's Guide DPDS3-PB-200017 - PDS ISOGEN Reference Guide, Vol. 1 DPDS3-PB-200022 - PDS Piping Component Data Reference Guide DPDS3-PB-200023 - PDS Project Setup Technical Reference DPDS3-PB-200025 - PDS Stress Analysis Interface (PD_Stress) User's Guide DPDS3-PB-200026 - Pipe Supports Modeler Reference Guide DPDS3-PB-200028 - Piping Design Graphics (PD_Design) Reference Guide DPDS3-PB-200030 - Project Administrator (PD_Project) Reference Guide DPDS3-PB-200033 - Project Engineer HVAC (PE-HVAC) Reference Guide DPDS3-PB-200034 - Reference Data Manager (PD_Data) Reference Guide DPDS3-PB-200035 - Report Manager (PD_Report) User's Guide DPDS3-PB-200041 - PDS EDEN Interface Reference Guide Volume 2 : Equipment DPDS3-PB-200042 - PDS EDEN Interface Reference Guide Volume 3 : Pipe Supports DPDS3-PE-200016 - PDS Express Project Creation Quick Start Guide DPDS3-PE-200052 - PDS Ortho Draw User's Guide DPDS3-PE-200029 - Piping Model Builder (PD_Model) Reference Guide DPDS3-PE-200031 - Project Engineer HVAC Getting Started Guide DPDS3-PE-200032 - Project Engineer HVAC Overview DPDS3-PE-200045 - PDS Label Library Merger Utility DPDS3-PE-200047 - PDS Reference Data Auditing Tool DPDS3-PE-200048 - Pipe Supports Explorer Utility DPDS3-PE-200050 - Batch Services Quick Start Guide DPDS3-PE-200051 - Batch Services User's Guide

Plant Design System (PDS) Piping Eden Interface

5

What's New in Piping Eden Interface

What's New in Piping Eden Interface The following changes have been made to the Piping Eden Interface: Version 2011 (V12)  No changes were made for this release. Version 2010  Added key numbers and gadget numbers for the following commands: Piping on Segment, Point on Pipe, Move from Active Point, Move from Reference Point, Move to Coordinate Axis, Intersection with Steel, and Connect to Piping. For more information, see Piping Specialty Components (on page 84) (P4 PB:110372).

6

Plant Design System (PDS) Piping Eden Interface

SECTION 1

The Eden Basics Eden is a high-level symbol definition language modeled on the FORTRAN programming language. The Eden language syntax is not case sensitive, except for module names, which are upper case. You can write code with whatever case conventions make it easiest for you to read. Eden allows you to design your own symbols for piping, instrumentation, specialty items, and equipment. While you do not need a programming background to write Eden programs, any programming experience is highly recommended. You also need to be familiar with an ASCII text editor, such as vi, emacs, or Notepad. Most of the symbol definition functions are built into Eden's command structure. This high-level command structure makes it easier to share code among several symbol definitions. For example, when designing a gate valve, the symbol definitions are used: GATSP

short pattern gate valve

GAT

long pattern, bolted or male ends gate valve

GATF

regular pattern, female ends, full port gate valve

GATR regular pattern, female ends, reduced port gate valve These symbol definitions identify four specifically unique gate valves; however, each of these valves refers to the same:  Primary physical data module (V1_AMS), which defines the specific dimensions and physical properties of a gate valve.  Generic physical data module (VALVE_2_AMS), which defines flange thickness, gasket separation, and outside separation.  Model graphic (V1). By sharing these modules, you will not fill up valuable disk space with redundant data, which can also increase valuable processing time. Eden is flexible enough to allow you to design codes specific to your company's needs, yet offers predefined subroutines, called primitives, which carry out functions often repeated within symbol definitions. For example, the following primitive draws a cone with a length of X units, a diameter at the active point (first end) of Y units and a diameter at the opposite end of Z units: Call Draw_Cone (X, Y, Z) The output produced will look similar to the following graphic:

You can call up to five nested subroutines within a program.

Plant Design System (PDS) Piping Eden Interface

7

The Eden Basics

Graphic Commodity Data The graphic commodity data is contained in the following object libraries:  Graphic Commodity Library (on page 8) --- The delivered file ~\pdshell\lib\pip_gcom.l contains parametric definitions for the components.  Physical Data (Dimensions) Library (see "Physical Data Tables" on page 10) --- The delivered file ~\rdusrdb\us_pcdim.l contains American dimension data for components.  Piping Job Specification Table Library --- The delivered file ~\rdusrdb\us_pjstb.l contains specification tables referenced in the Piping Job Specification. See the Piping Job Specification section in the Reference Data Manager Reference Guide for more information. Refer to Reference Data Overview section in the Reference Data Manager Reference Guide for more information. When you select a component for placement in the model, the system:  Uses the active parameters (such as piping materials class and nominal diameter) to search the Piping Job Specification (PJS) for the selected item name. If the selected item is found in the PJS database, the system reads the PJS for the parameters required to place the component. Included in this information is the model code (or specialty item number) for the selected component and the names of the spec tables defined for the Piping Materials Class.  Uses the model code (or specialty item number), derived from the PJS, to access the graphic commodity library. The definitions in the graphic commodity library determine the physical tables required to place the component and call the tables in the physical commodity library.  Places the symbol graphics in the model design file and writes the nongraphic information for the component in the database. This section describes the graphic commodity data used in placing components in the piping model. Refer to the Piping Design Graphics Reference Guide for a detailed description of the actual placement process.

See Also Notes for Graphic Commodity Data (on page 26)

Graphic Commodity Library The Graphic Commodity Library (GCL) provides data for commodity items, engineered items, and instruments. It is basically a catalog of component data which is accessed to:  Determine physical data based on user specifications (such as NPD and end preparation)  Assign connect point data from the Piping Job Specification  Define the parametric shape for the model graphics. The Graphic Commodity Library includes data required for model creation, resymbolization for model presentation, interference detection, and any special functions of the Piping Job Specification, piping industry standards, or company design practices. PDS Piping uses the Eden Parametric Language to define and place components, specialty items, operators, and envelopes. Eden is a high level language (similar to FORTRAN) which uses information from the Piping Job Specification and model to access parametric and dimensional data. Eden is composed of three major modules. 1. Symbol Processors and Sub-Symbol Processors

8

Plant Design System (PDS) Piping Eden Interface

The Eden Basics 2. Physical Data Subroutines 3. Parametric Shape Definitions These modules are designed to carry out two functions: data definition and graphic presentation. The data associated with these modules is delivered in the following files: ~\pdshell\lib\pip_gcom.l --- object library ~\pdshell\lib\pip_gcom.l.t --- text library The modular approach provides for more efficient storage of information in these libraries by enabling common information to be shared by different symbols. The first line of each Eden module defines the type of module (such as symbol processor) and the module name. This statement determines a two-character category code to be prefixed to the module name in the object library. This prefix is only used by the system; it should not be keyed in as part of the module name. The following image illustrates the Eden Module Relationships.

Plant Design System (PDS) Piping Eden Interface

9

The Eden Basics The entries in the library use the following prefixes to identify the type of data: SP

Symbol Processor

PD

Physical Data Definition Module

UF

User Function Module

MG

Model Parametric Shape Definition Module

IG

Interference Envelope Parametric Shape Definition Module

SS Sub-Symbol Processor Module Each module must be given a unique name within the graphic commodity library.

Physical Data Tables The physical data tables contain the physical data (dimensions, weights, and surface area) required for symbol creation, interference detection, stress analysis, and MTO reporting. These tables are segregated for commodity item data, engineered item data, and instrument data. Refer to the Reference Data Manager Reference Guide for a detailed description of the physical data tables and the table naming conventions used in PDS. The physical data tables for US Practice are delivered in the following files: ~\rdusrdb\us_pcdim.l --- object library ~\rdusrdb\us_pcdim.l.t --- text library ~\rdusrdb\us_pcdim.l.r --- revision library These libraries contain physical data for American standards. The physical data can be stored in one of ten physical data libraries. The system uses the geometric industry standard for a particular commodity item (or specialty item) to determine which library to reference for the physical data tables. Geometric industry standard is expressed as a code list value from Standard Note Type 575. Code list numbers 2-6999 are reserved for standards that apply to American piping practices. Code list numbers 7000-27999 are reserved for standards that apply to European piping practices. Numbers 28000-31999 are reserved for specific company practices. By segregating data into separate physical data libraries, you can access a subset of the total physical data available for a project. You can also build a specific set of physical data for a particular project. The following table types are required for piping and instrument components:  Generic dimensional data Generic tables contain data that is not specific to a particular symbol (such as flange outside diameter or flange thickness). These tables are identified by the prefix BLT, FEM, or MAL (for the termination type) and end with the extension .TBL (the table name is independent of the name of the physical data module).  Specific commodity data Specific tables contain commodity data that is specific to a particular component (such as dimensions, water weight, and surface area). These specific tables use the model code or commodity code as part of the table name to classify data by symbol type.  The system uses the water weight data to compute the wet weight using the specific gravity of the operating fluid. fluid weight = water weight * specific gravity for fluid operating weight = dry weight + fluid weight

10

Plant Design System (PDS) Piping Eden Interface

The Eden Basics 

The surface area data enables the system to perform paint requirement calculations and insulation weight calculations.  Specific commodity dry weight data  Piping Specialty physical data The dimensions, dry weight, water weight, and surface area for specialty items can be stored in a set of tables or defined at placement.  Instrument physical data The dimensional data, dry weight, water weight, and surface area for instruments can be stored in a set of tables or defined at placement. You can form the name of a physical data table from attributes for the component (such as geometry standard and end preparation). However, the table name cannot exceed 46 characters.

See Also Data Retrieval from the Physical Data Library (on page 11) Example of Physical Data Look-Up (on page 11)

Data Retrieval from the Physical Data Library The data retrieval from tables in the Physical Data Library is restricted to two independent variables and eight dependent variables. If only one independent variable is required, then nine dependent variables are allowed. If more independent variables are required, the additional independent variable(s) must be a part of the table name. If nominal diameter is one of the independent variables, it must be listed first in the table.

Example of Physical Data Look-Up In order to place the valve described earlier in this section, the system references the following tables:

Generic Tables The spec access for a six-inch gate valve defines the end preparation at both connect points as Raised Face Flanged End (code list value 21), which is a bolted connection. As shown in the listing for VALVE_2_AMS, the table name for a bolted connection on a two-connect point valve is table_name= 'BLT' // Term_Type_1 // Pr_Rating_1 // Gen_Flag_Green Using the values from the Piping Job Specification (PMC=1C0031, Item Name=6Q1C01), the actual table name will be: BLT_20_150_5 This table returns the outside diameter, flange thickness, and the seating depth for each end of the valve. Note that the termination type (20) is used rather than the actual end preparation value (21).

Specific Tables The specific tables are used to define the main body of the valve. Refer to the Table Requirement section in the Reference Data Manager Reference Guide for an outline of the types of tables that are required to place a valve. Since the termination type is the same at both ends of the valve (bolted), no red connect point data is required. The required tables are found by referring to the Bolted(G) termination type.  MC_GS_Term(G)_Rat(G)_A (P15A).

Plant Design System (PDS) Piping Eden Interface

11

The Eden Basics 

MC_GS_Term(G)_Rat(G)_B (P15B) --- This table is only required if more than eight outputs are necessary to define a commodity item.  Commodity Code (P59). Using this information, the dimension tables for a 6" gate valve are:  GAT_40_20_150_A This table returns the face-to-center dimension for the valve. Table P15B is not required for a gate valve.  VAABAHCCAA This table returns the empty weight of the valve, including the weight of the operator. If the end preparations were different at each end of the valve (such as female threaded by socket welded), then a different set of tables would be required. An additional table look-up is required to access the dimensional data for the valve operator. The following table is required to define the valve operator: MC_Type(G)_Rat(G)_Op_A (P31A) Using this table name format, the dimension table for a handwheel operator on a 6" gate valve is: GAT_BLT_150_3_A This table returns the stem length and the wheel diameter for the handwheel operator.

12

Plant Design System (PDS) Piping Eden Interface

SECTION 2

Component Placement Example This section provides a step-by-step example of how PDS uses Eden and the information in the physical dimension tables to place components in a model.

Eden Modules Eden is composed of three major modules: 1. Symbol Processors (on page 15) Sub-Symbol Processors (see "Sub-Symbol Processor" on page 16) 2. Physical Data Subroutines (see "Physical Data Definitions" on page 17) 3. Parametric Shape Definitions (on page 23) These modules are designed to carry out two functions: data definition and graphic presentation. The data associated with these modules is delivered in the following files: ~\pdshell\lib\pip_gcom.l --- object library ~\pdshell\lib\pip_gcom.l.t --- text library The modular approach provides for more efficient storage of information in these libraries by enabling common information to be shared by different symbols.

Plant Design System (PDS) Piping Eden Interface

13

Component Placement Example The following graphic, Eden Module Relationships, illustrates the relationship among these modules:

The first line of each Eden module defines the type of module (such as symbol processor) and the module name. This statement determines a two-character category code to be prefixed to the module name in the object library. This prefix is only used by the system; it should not be keyed in as part of the module name. The entries in the library use the following prefixes to identify the type of data:

14

SP

Symbol Processor

PD

Physical Data Definition Module

UF

User Function Module

MG

Model Parametric Shape Definition Module

Plant Design System (PDS) Piping Eden Interface

Component Placement Example IG

Interference Envelope Parametric Shape Definition Module

SS Sub-Symbol Processor Module Each module must be given a unique name within the graphic commodity library.

Symbol Processors A symbol processor is the controlling function or logic used to produce the graphics for a commodity item, piping specialty, instrument, pipe support, or interference envelope. During component placement, the symbol processor:  Accesses the active component design parameters  Assigns connect points  Calls the required physical data modules  Determines and calls the required parametric shape modules. The system retrieves the active component parameters which are dependent upon a connect point from the PJS in terms of green, red, or tap connect point properties. The symbol definition assigns the data corresponding to these connect point types (green, red, or tap) to the physical connect point numbers (CP1, CP2, CP3, CP4, or CP5). The first line of the Eden module defines the type of module and the module name. The following statement is used in the Eden modules to indicate a symbol processor module. Symbol_Processor 'MODULE NAME' This statement tells the system to use the category code SP for the prefix. You should use the following conventions in assigning the module name (the module name must be in UPPER CASE). The module name is determined by the type of component being placed (commodity item or specialty item).  For a commodity item, the system searches for the New Item Name (model code) of the commodity item as the module name. If the New Item Name is blank in the Commodity Item entity, the system searches for the Item Name as the module name.  For a specialty item, the system searches for the specialty item name (derived from the PJS) as the module name.  For an instrument, the system searches for the instrument name (derived from the PJS) as the module name. The delivered symbol processors are identified in the library with the prefix SP. The following lists the symbol processor SPGAT, which is used to control the placement of a gate valve.

Plant Design System (PDS) Piping Eden Interface

15

Component Placement Example Listing for Symbol Processor SPGAT ! REGULAR PATTERN, BOLTED OR MALE ENDS GATE VALVE Symbol_Processor 'GAT' Call Assign_Connect_Point ( GREEN, CP1 ) Call Assign_Connect_Point ( RED, CP2 ) physical_data_source = 'V1' // Standard_Type Call Get_Physical_Data ( physical_data_source ) parametric_shape = 'V1' Call Draw_Parametric_Shape ( parametric_shape ) Valve_Operator = DABS ( Valve_Operator ) If ( Valve_Operator .NE. 0 ) Then If ( Valve_Operator .LT. 1000 ) Then Subcomponent = 'OP' // Valve_Operator Else Subcomponent = 'A' // Valve_Operator EndIf Operator_Orient = FALSE EndIf Stop End

Sub-Symbol Processor A subcomponent call in a symbol processor module indicates a sub-symbol processor. Subcomponents are additions to symbols such as an operator on a valve. The first line of a sub-symbol processor module indicates the module type and the module name. Sub_Symbol_Processor 'module name' This statement tells the system to use the category code SS for the prefix. The sub-symbol processor name for operators is a concatenation of the characters OP_ and the modifier value from the Commodity Item entity in the PJS database. The value is expressed as a code list number from CL550 (operator/actuator type). If the value is a positive number (such as 3) the operator is placed with the valve. If the value is a negative number (such as -3) the operator is not placed with the valve. (This is useful in segregating large diameter valves which almost always display a valve operator from small diameter valves, which frequently do not display an operator in the model.) The symbol processor for the gate valve calls a sub-symbol processor (Subcomponent = 'OP' // Valve_Operator), which places an operator on the valve. The following depicts the sub-symbol processor SSOP_3, which is used to control the placement of a handwheel operator on the valve.

16

Plant Design System (PDS) Piping Eden Interface

Component Placement Example Listing for Sub-Symbol Processor SSOP_3 ! HANDWHEEL OPERATOR Sub_Symbol_Processor 'OP_3' If ( Operator_Orient .EQ. TRUE ) Then prompt = 1.0 Call Prompt_to_Orient_Operator ( prompt ) EndIf physical_data_source = 'OPERATOR_3' Call Get_Physical_Data ( physical_data_source ) parametric_shape = 'OP3' Call Draw_Parametric_Shape ( parametric_shape ) Stop End

Physical Data Definitions The system uses the physical data definitions to determine the dimension data, weight data, and surface area data using the active design parameters. Physical data modules are identified by the statement: Physical_Data_Definition 'MODULE NAME' as the first line in the Eden module. This statement tells the system to use the category code PD for the prefix. This prefix is only used by the system; it should not be keyed in as part of the module name. The module name for a physical data module consists of a symbol type (such as V1, V2,... for valves) and a generic type of geometric industry standard (such as AMS or DIN). You can define multiple physical data modules for the same symbol depending on the type of standard being referenced (for example, V1_AMS for American standards and V1_DIN for European standards). You can manage ten different sets of logic for table naming conventions for the following industry practices. The corresponding table suffix ranges and the suffix for the Piping Eden physical data modules are indicated below. Practice

Range

Suffix

U.S. Practice

1-99

AMS

European - DIN

100-199

DIN

European - British Standard

200-299

BRITISH_STD

European - Practice A

300-399

EURO_A

International - JIS

400-499

JIS

International - Australian

500-599

AUS

European - Practice B

600-699

EURO_B

International - Practice A

700-799

INT_A

International - Practice B

800-899

INT_B

Company Practice 900-999 COMPANY The table suffix standard for a component is defined in the Piping Commodity Data table of the Material Reference Database. Each component must be assigned a geometric industry standard if it is to use physical data tables.

Plant Design System (PDS) Piping Eden Interface

17

Component Placement Example For most of the delivered symbols, the physical data modules are classified into two categories: specific and generic. The specific physical data module is called by the symbol processor. This module then calls a generic physical data module.

Specific Physical Data Modules The physical data module PDV1_AMS determines the specific dimensions (face-to-center and face-to-face) and other physical properties for a gate valve. This is the module called by the symbol processor SP_GAT.

Listing for Physical Data Module PDV1_AMS Physical_Data_Definition 'V1_AMS' physical_data_source = 'VALVE_2_AMS' Call Get_Physical_Data ( physical_data_source ) Call Read_Table ( Table_Name_A, input, output ) Surface_Area = Output_1 Wet_Weight = Output_2 F_to_C_Dim_1 = Output_3 If ( Term_Type_1 .EQ. Term_Type_2 ) Then F_to_C_Dim_2 = F_to_C_Dim_1 Else F_to_C_Dim_2 = Output_4 EndIf F_to_F_Dim = F_to_C_Dim_1 + F_to_C_Dim_2 If ( Valve_Operator .LE. 24.0 ) Then Call Read_Table ( Table_Name_W, input, output ) Dry_Weight = Output_1 EndIf Return End

Generic Physical Data Modules The generic modules contain information that is common to more than one symbol, such as flange thickness, gasket separation, and outside diameter. The physical data module V1_AMS calls another physical data module VALVE_2_AMS, which contains the generic dimension data for all valves with two connect points.

18

Plant Design System (PDS) Piping Eden Interface

Component Placement Example Listing for Physical Data Module PDVALVE_2_AMS Physical_Data_Definition 'VALVE_2_AMS' Input_1 = Nom_Pipe_D_1 If ( Gen_Type_1 .EQ. BOLTED ) Then table_name = 'BLT' // Term_Type_1 // Pr_Rating_1 // Gen_Flag_Green Call Read_Table ( table_name, input, output ) Facing_OD_1 = Output_1 Thickness_1 = Output_2 Seat_Depth_1 = Output_3 Thickness_1 = Thickness_1 - Seat_Depth_1 CP_Offset_1 = Gasket_Sep_1 If ( Symbology .EQ. MODEL ) Then Thickness_1 = 0.0 Depth_1 = 0.0 Pipe_OD_1 = 0.0 Body_OD_1 = Facing_OD_1 Else table_name = 'MAL_300_5' Depth_1 = Thickness_1 Input_1 = Nom_Pipe_D_1 Call Read_Table ( table_name, input, output ) Pipe_OD_1 = Output_2 Body_OD_1 = Pipe_OD_1 EndIf Else If ( Gen_Type_1 .EQ. MALE ) Then table_name = 'MAL' // Term_Type_1 // Gen_Flag_Green Call Read_Table ( table_name, input, output ) Facing_OD_1 = Output_2 Thickness_1 = 0.0 Depth_1 = 0.0 Seat_Depth_1 = 0.0 CP_Offset_1 = 0.0 Pipe_OD_1 = Facing_OD_1 Body_OD_1 = Facing_OD_1 Else table_name = 'FEM' // Term_Type_1 // Pr_Rating_1 // Gen_Flag_Green Call Read_Table ( table_name, input, output ) Facing_OD_1 = Output_1 Depth_1 = Output_2 Seat_Depth_1 = 0.0 Thickness_1 = 0.0

Plant Design System (PDS) Piping Eden Interface

19

Component Placement Example If ( symbology .EQ. MODEL ) Then Depth_1 = 0.0 CP_Offset_1 = 0.0 Pipe_OD_1 = 0.0 Body_OD_1 = Facing_OD_1 Else CP_Offset_1 = -Depth_1 table_name = 'MAL_300_5' Call Read_Table ( table_name, input, output ) Pipe_OD_1 = Output_2 Body_OD_1 = Pipe_OD_1 EndIf EndIf EndIf If ( Term_Type_2 .EQ. Term_Type_1 .AND. Nom_Pipe_D_1 .EQ. Nom_Pipe_D_2 ) Then Facing_OD_2 = Facing_OD_1 Pipe_OD_2 = Pipe_OD_1 Body_OD_2 = Body_OD_1 Thickness_2 = Thickness_1 Depth_2 = Depth_1 Seat_depth_2 = Seat_Depth_1 CP_Offset_2 = CP_Offset_1 Else Input_1 = Nom_Pipe_D_2 If ( Gen_Type_2 .EQ. BOLTED ) Then table_name = 'BLT' // Term_Type_2 // Pr_Rating_2 // Gen_Flag_Red Call Read_Table ( table_name, input, output ) Facing_OD_2 = Output_1 Thickness_2 = Output_2 Seat_Depth_2 = Output_3 Thickness_2 = Thickness_2 - Seat_Depth_2 CP_Offset_2 = Gasket_Sep_2 If ( Symbology .EQ. MODEL ) Then Thickness_2 = 0.0 Depth_2 = 0.0 Pipe_OD_2 = 0.0 Body_OD_2 = Facing_OD_2 Else Depth_2 = Thickness_2 table_name = 'MAL_300_5' Input_1 = Nom_Pipe_D_2 Call Read_Table ( table_name, input, output ) Pipe_OD_2 = Output_2 Body_OD_2 = Pipe_OD_2 EndIf

20

Plant Design System (PDS) Piping Eden Interface

Component Placement Example Else If ( Gen_Type_2 .EQ. MALE ) Then table_name = 'MAL' // Term_Type_2 // Gen_Flag_Red Call Read_Table ( table_name, input, output ) Facing_OD_2 = Output_2 Thickness_2 = 0.0 Depth_2 = 0.0 Seat_Depth_2 = 0.0 CP_Offset_2 = 0.0 Pipe_OD_2 = Facing_OD_2 Body_OD_2 = Facing_OD_2 Else table_name = 'FEM' // Term_Type_2 // Pr_Rating_2 // Gen_Flag_Red Call Read_Table ( table_name, input, output ) Facing_OD_2 = Output_1 Depth_2 = Output_2 Seat_Depth_2 = 0.0 Thickness_2 = 0.0 If ( Symbology .EQ. MODEL ) Then Depth_2 = 0.0 CP_Offset_2 = 0.0 Pipe_OD_2 = 0.0 Body_OD_2 = Facing_OD_2 Else CP_Offset_2 = -Depth_2 table_name = 'MAL_300_5' Input_1 = Nom_Pipe_D_2 Call Read_Table ( table_name, input, output ) Pipe_OD_2 = Output_2 Body_OD_2 = Pipe_OD_2 EndIf EndIf EndIf EndIf Table_Name_A = Item_Name // Geo_Ind_Std // Term_Type_1 Table_Name_W = Commodity_Code Input_1 = Nom_Pipe_D_1 Input_2 = Nom_Pipe_D_2 If ( Term_Type_1 .EQ. Term_Type_2 .AND. Nom_Pipe_D_1 .EQ. Nom_Pipe_D_2 ) Then Table_Name_A = Table_Name_A // Pr_Rating_1 // 'A' Else If ( Gen_Type_1 .EQ. Gen_Type_2 ) Then ! Male X Male or Bolted X Bolted ! or Female X Female Table_Name_A = Table_Name_A // Pr_Rating_1 // Term_Type_2 // Pr_Rating_2 // 'A' Else

Plant Design System (PDS) Piping Eden Interface

21

Component Placement Example If ( Gen_Type_1 .EQ. MALE ) Then ! Female

Male X Bolted and Male X Table_Name_A = Table_Name_A // Term_Type_2 // Pr_Rating_2 //

'A' !

Else If ( Gen_Type_2 .EQ. MALE ) Then Bolted X Male and Female X

Male Table_Name_A = Table_Name_A // Pr_Rating_1 // Term_Type_2 // Else !

Bolted X Female and Female

X Bolted Table_Name_A = Table_Name_A // Pr_Rating_1 // Term_Type_2 // Pr_Rating_2 // 'A' EndIf EndIf EndIf EndIf Return End

Listing for Physical Data Module OPERATOR_3 Physical_Data_Definition 'OPERATOR_3' Input_1 = Nom_Pipe_D_1 If ( Gen_Type_1 .EQ. BOLTED ) Then Table_Name_A = Item_Name // 'BLT' // Pr_Rating_1 // Valve_Operator // 'A' Else If ( Gen_Type_1 .EQ. MALE ) Then Table_Name_A = Item_Name // 'MAL' // Pr_Rating_1 // Valve_Operator // 'A' Else If ( Gen_Type_1 .EQ. FEMALE ) Then Table_Name_A = Item_Name // 'FEM' // Pr_Rating_1 // Valve_Operator // 'A' EndIf EndIf EndIf Call Read_Table ( Table_Name_A, input, output ) Dimension_1 = Output_1 Dimension_2 = Output_2 OP_Weight = 0.0 Return End

22

Plant Design System (PDS) Piping Eden Interface

Component Placement Example

Parametric Shape Definitions The parametric shape definition describes the graphics symbol (such as bend, flange, or valve body) that is placed for the component in the model. Parametric shape definitions are used to place symbol graphics in the model or define interference envelopes. This involves the following major functions:  Defining connect point geometry  Placing connect points  Moving the active location a specified distance  Drawing a specific graphic shape  Placing a center of gravity location. Parametric shape definitions are divided into two basic types: model parametric shapes and interference envelopes. The first line of the Eden module indicates the module type and the module name.

Model Parametric Shape Definitions Model parametric shapes are used to define the symbol graphics to be placed in the model. For example, the parametric shape module for a valve consists of a cylinder, two cones, and a cylinder (flange, valve body, flange). The first line for these modules is of the form Model_Parametric_Shape_Definition 'MODULE NAME' This statement tells the system to use the category code MG for the prefix. This prefix is only used by the system; it should not be keyed in as part of the module name. The module name for a parametric shape module consists of a symbol type (such as V1, V2,... for valves). The parametric shape module MGV1 determines the model graphics for a valve. This is the module called by the symbol processor SPGAT. The parametric shape module MGOP3 determines the model graphics for a handwheel operator. This is the module called by the sub-symbol processor SSOP_3.

Listing for Parametric Shape Module MGV1 Model_Parametric_Shape_Definition 'V1' Call Define_Connect_Point_Geometry ( LINEAR ) Call Place_Connect_Point ( CP1 ) Call Move_By_Distance ( CP_Offset_1 ) Call Draw_Cylinder_With_Capped_Ends ( Depth_1, Facing_OD_1 ) length = F_to_C_Dim_1 - Thickness_1 diameter = 0.0 Call Draw_Cone ( length, Body_OD_1, diameter ) Call Place_Connect_Point ( CP0 ) Call Place_COG_Location ( DRY_COG ) Call Place_COG_Location ( WET_COG ) length = F_to_C_Dim_2 - Thickness_2 Call Draw_Cone ( length, diameter, Body_OD_2 ) Call Draw_Cylinder_With_Capped_Ends ( Depth_2, Facing_OD_2 ) Call Move_By_Distance ( CP_offset_2 ) Call Place_Connect_Point ( CP2 ) Return End

Plant Design System (PDS) Piping Eden Interface

23

Component Placement Example

Listing for Parametric Shape Module MGOP3 Model_Parametric_Shape_Definition 'OP3' Call Define_Connect_Point_Geometry ( OPERATOR ) Call Convert_NPD_to_Subunits ( Nom_Pipe_D_1, dia ) dist = dia + Min_Cyl_Dia * 0.5 angle = 90.0 radius = ( Dimension_2 - Min_Cyl_Dia ) * 0.5 Call Draw_Cylinder_With_Capped_Ends ( Dimension_1, Min_Cyl_Dia ) Call Move_by_Distance ( -dist ) Call Rotate_Orientation ( angle, Secondary ) Call Rotate_Orientation ( angle, Normal ) Call Move_Along_Axis ( -radius, Secondary ) Call Draw_Torus ( radius, angle, Min_Cyl_Dia ) Call Draw_Torus ( radius, angle, Min_Cyl_Dia ) Call Draw_Torus ( radius, angle, Min_Cyl_Dia ) Call Draw_Torus ( radius, angle, Min_Cyl_Dia ) Return End

Interference Parametric Shape Definition Interference parametric shapes are not used during component placement. They are referenced during interference detection to determine the volume (interference envelope) to be compared for clashes with other elements. If a clash is detected during the interference detection process, the interference parametric shape is used to place an interference marker. Refer to the PDS Interference Checker/Manager (PD_Clash) User's Guide for more information on interference envelopes. Interference_Parametric_Shape_Definition 'MODULE NAME' This statement tells the system to use the category code IG for the prefix. The module name for the interference parametric shape definition should be the same as the module name for the model parametric shape definition. If no interference module is found for a component, the system uses the model graphics module to determine the interference parametric shape.

24

Plant Design System (PDS) Piping Eden Interface

Component Placement Example Listing for VI IFC Interference_Parametric_Shape_Definition 'V1' Call Define_Connect_Point_Geometry ( LINEAR ) dist = 0.0 If ( Gen_Type_1 .EQ. BOLTED ) Then extra1 = CP_Offset_1 Else extra1 = 0.0 dist = CP_Offset_1 EndIf If ( Gen_Type_2 .EQ. BOLTED ) Then extra2 = CP_Offset_2 Else extra2 = 0.0 EndIf sec1 = Depth_1 + extra1 sec2 = Depth_2 + extra2 diameter1 = Facing_OD_1 + Insulation * 2.0 diameter2 = Facing_OD_2 + Insulation * 2.0 diameter3 = Body_OD_1 + Insulation * 2.0 length = F_to_C_Dim_1 - Thickness_1 + F_to_C_Dim_2 - Thickness_2 Call Move_By_Distance ( dist ) If ( diameter1 .GE. diameter2 ) Then Call Draw_Cylinder_With_Capped_Ends ( sec1+sec2+length, diameter1 ) Else Call Draw_Cylinder_With_Capped_Ends ( sec1+sec2+length, diameter2 ) EndIf Return End

Listing for OP3 IFC Interference_Parametric_Shape_Definition 'OP3' Call Define_Connect_Point_Geometry ( OPERATOR ) Call Convert_NPD_to_Subunits ( Nom_Pipe_D_1, dia ) dist = dia + Min_Dimension * 0.5 Call Draw_Cone_With_Capped_Ends ( Dimension_1 - dia, 0.0, Dimension_2 ) Call Draw_Cylinder_With_Capped_Ends ( dia, Dimension_2 ) Return End

Plant Design System (PDS) Piping Eden Interface

25

Component Placement Example

Forms Interface Forms in piping design serve to collect input via key-in fields or command buttons. They also provide feedback information to the user through message fields. The data gathered through the forms serves as the input that defines the values of the global variables used by the Eden modules. When a new specialty item is defined through Eden a form specific to that item can be created using the Form Builder and Symbol Editor products, or the DBAccess product.

Notes for Graphic Commodity Data The following sections provide additional information about graphic commodity data.  Connect Point Data (on page 26)  Bends and Branches (on page 28)  Bolts, Gaskets, and Flanges (on page 28)  Pipe, Tubing, and Hose (on page 29)

Connect Point Data As described in the Piping Job Specification description, connect point information for commodity items, piping specialties, and instruments is classified in terms of green and red connect points. The following conventions are used to coordinate the two sets of data:  For full-size components, data is only defined for the green connect point and applies to all ends of the component.  For size change components, data for commodity items, speciality items, or instruments should be created with the green connect point representing the larger diameter (first size) of the component and the red connect point diameter representing the smaller diameter (second size). If the end preparation is different at each end of the component, the end preparation should be defined to match the required green and red connect points.  If a component has ends with the same nominal diameter but other end properties that differ, the following rules apply:  If the ends have different end preparations (regardless of the values for schedule/thickness) the end(s) whose end preparations have the lowest code list number are designated as the green connect point.  If the end preparations are the same but the values for rating, schedule, or thickness differ, the "stronger" end(s) are designated as the green connect point.  Schedule or thickness values should be defined for all applicable components. Refer to the PJS Tables and Functions section in the Reference Data Manager (PD_DATA) Reference Guide for a detailed description of the methods for defining the schedule or thickness value.  A flow direction component (such as a check valve) must be defined so that the flow is directed from connect point 1 to connect point 2.

26

Plant Design System (PDS) Piping Eden Interface

Component Placement Example 

A tee type branch must be defined with connect point three on the branch leg of the tee.

 

The origin of a component must lie between connect point 1 and connect point 2. Flanges should be defined with the green connect point representing the flanged connect point and the red connect point representing the non-flanged connect point.



A valve operator is always placed at the component origin of the corresponding valve body.



To ensure consistency in pipe cut length calculations, the connect points of a component should be located using face-to-face or face-to-center dimension rather than end-to-end or end-to-center dimension. A change of direction component placed by component center must be defined such that connect point 1 is on the primary axis.



Plant Design System (PDS) Piping Eden Interface

27

Component Placement Example

Bends and Branches 





For bend components (specific and generic), the item name must be unique with respect to the angle of the bend. In other words, you specify the angle of the bend by selecting the item name for the corresponding angle of the bend. The number of joints in a miter is required to compute the stress intensification factor (SIF). The graphics symbol description in the Graphic Commodity Library sets an attribute in the piping design database that defines the number of joints. For miter bend components, the system requires that the item name and the new item name be unique with respect to the number of miter joints of the bend. In other words, the item name specifies the number of miter joints of the bend. For branches (tees and laterals), the system uses the first and second size to access the branch table and to determine the item name of the component to be placed at the branch point (intersection). Depending on the active values, the branch table may define a single component or a set of two or three components.

Bolts, Gaskets, and Flanges 

 



28

The data for the number of bolts and the bolt diameter is available with the flange data in the Physical Dimension Table Library as a function of nominal piping diameter, pressure rating, termination type, and geometric industry standard. However, the bolt data and the flange data are stored in separate tables. Refer to the Report Manager (PD_Report) User's Guide for a description of the table access. A lap joint flange is defined with the end preparation at one end as flanged and the other end as lap. The system determines the gasket separation at each connect point of a piping component, speciality item, and an instrument component by the following rules:  If the end preparation for the connect point is flanged, the gasket separation for the connect point is set to one-half the Active Gasket Separation. However, some flanged connections (lug, ring type joint, or wafer) have integral gaskets and do not have a gasket separation. In this situation, the gasket separation at each connect point is set to zero.  If the end preparation for the connect point is not flanged, the gasket separation for the connect point will be set to zero. Flange data exists in two tables.  The first table (BLT_Term_Rat_TS) contains the flange data required for modeling activities (such as flange outside diameter and flange thickness).  The second table (STUD_Rat_TS) contains flange data required for reporting or analysis activities (such as bolt diameter, number of bolt holes, and nut extension).

Plant Design System (PDS) Piping Eden Interface

Component Placement Example

Pipe, Tubing, and Hose 

  



All tubing (such as fiberglass and copper) is specified in terms of piping outside diameter rather than nominal piping diameter. All commodity item data in the Physical Dimension Table Library exists in terms of nominal piping diameter. Mechanical joint and cast iron pipe can have various fixed lengths. Polypropylene-lined tube is purchased with flanged ends in various fixed lengths. Piping wall thickness is defined in terms of NPD units rather than model units. A piping converter component (which converts nominal piping diameter from one system of units to another system of units) must be defined in the PJS database for each specific pair of nominal piping diameters. You cannot specify a converter component for a range of nominal piping diameters. Flexible hose has flanged, screwed, or quick disconnect end preparations.

Plant Design System (PDS) Piping Eden Interface

29

Component Placement Example

30

Plant Design System (PDS) Piping Eden Interface

SECTION 3

Eden Language Structure Eden is similar to the FORTRAN programming language. Therefore, the general rules for evaluating expressions in Eden are identical to those in FORTRAN. You do not need to know FORTRAN to use the Eden language. Eden definitions are usually simpler than FORTRAN programs. To use Eden, you must be able to visualize the symbol (in 3D) that you want to develop. The Eden language structure incorporates:  Statements  Beginning  Ending  Variables  Local  Global  Keywords  Connect Point Geometry (piping only)  Operators  Arithmetic  Relational  Logical  Expressions  Functions  Primitives (or Subroutines)

Beginning Statements Beginning statements define the types of modules being entered. Names within the single quotes must be all upper case. SP - Symbol_Processor '6CHAR' SS - Sub_Symbol_Processor '6CHAR' PD - Physical_Data_Definition '28CHAR' UF - User_Function_Definition '28CHAR' MG - Model_Parametric_Shape_Definition '28CHAR' IG - Interference_Parametric_Shape_Definition '28CHAR'

Examples Symbol_Processor 'GAT' Physical_Data_Definition 'V1_AMS'

Plant Design System (PDS) Piping Eden Interface

31

Eden Language Structure

Ending Statements Ending statements mark the end of the module in which the system has been processing. Ending statements in the symbol and subsymbol processor (beginning statements SP and SS) include: Stop End Ending statements in the children processor (beginning statements PD, UF, MG, and IG) include: Return End

Variables Variables in Eden can be either local or global. They can contain either numeric or alphanumeric data. Internally, numeric data is stored as REAL*8 (double precision). If a different data type is required in the context of an expression, then the conversion is performed at the time the expression is evaluated. Variable names can be either upper or lower case. Symbols tend to be easier to read when you use all lower case for local symbols and all upper case for global symbols or vice versa.

Examples   

When converting a floating point number to an integer, the fractional part of the floating point number is truncated. A variable used in a logical expression evaluates to TRUE when the value of the variable is 1 and 0 when the logical value is FALSE. Variables that hold values representing distances are assumed to be in subunits. A variable containing the value 25 represents 25 inches in an English unit design file and 25 millimeters in a metric unit design file. Be careful when using hard coded numbers or when using the system_of_units variable.

Local Variables Local variables are user defined and declared in the symbol definition. You can refer to a local variable only when you are in the same module as the local variable. Local variable names are formed using alphanumeric (a-z), numeric (1-9), and special (_ and $) characters. They must begin with an alphanumeric character and must be less than or equal to 31 characters in length. The Eden compiler does not verify the spelling of local variables within call statements. It assumes a null value for the misspelled variable at component placement time. The Eden language refers to constants as local variables. Both character strings and numeric constants are valid; however, character string constants must be surrounded by single quotes. In most cases, character strings and constants are case sensitive. Thus, a and A are interpreted differently.

32

Plant Design System (PDS) Piping Eden Interface

Eden Language Structure Examples diameter

13.25

shell_thickness

'A TEXT STRING'

projection_1

radius [2]

25 Only in Pipe Support and Equipment Modeling can you declare local variable types. The variable types default to either CHARACTER or REAL depending on the context. To override this default, you can use a local variable type declaration statement anywhere before the variable(s) is (are) actually referenced. Variable types INT2, R8, and LOCATION are recognized by the compiler.

Example In the following example, variables a, B, and C are declared as type short integers. They hold values ranging from -32767 to 32767. Int2 a Int2 B, C

Example In the example below, variable d is declared as a type REAL, capable of holding decimal fractional values. This is the usual default type for numeric variables. However, explicit typing to this category may be necessary to declare local arrays. R8 d As a recommendation, all declaration statements should be placed at the very beginning of the symbol code and not interspersed among statements to be executed during symbol placement. This improves program readability. Also in Pipe Support and Equipment Modeling, referencing a variable using subscripts is extremely useful when coding repetitive statements such as the body of a loop. Prior to use, variables must appear in a type declaration in which its subscript or index range is also specified.

Example Below, LENGTHS is an array of 10 REAL variables. They are referenced as LENGTHS [1] ... LENGTHS [10]. R8 LENGTHS [10]

Plant Design System (PDS) Piping Eden Interface

33

Eden Language Structure

Global Variables Common to Piping, Equipment, and Pipe Support Modeling Global variables are system-defined names allowing you to refer to them at any subroutine level. More specifically, you can use them for passing values between subroutine levels or for communicating input values to the symbol. The following list shows the global variables common to all Eden applications. Refer to the application-specific section for detailed information concerning specific global variables. Global variables are system-defined. You cannot declare global or subscripted global variables.

34

Input_n

(Input_1 through Input_20) An array with up to 20 variables used to define the input parameters for table lookups. (Input_11 through Input_20 are specifically designed for user function arguments in equipment and pipe support modeling.)

Output_n

(Output_1 through Output_20) An array with up to 20 variables where the results of the table lookup are stored. (Output_11 through Output_20 are specifically designed for user function return arguments in equipment and pipe support modeling.)

Dimension_n

(Dimension_1 through Dimension_20) General purpose variables used for communicating input to the symbol logic. You can also use these variables for passing values between subroutines or simply for local storage. (Dimension_20 is for angle; Dimension_1 through Dimension_19 is for linear piping.)

Pr_Rating_n

Variable containing the current item pressure rating value.

Nom_Pipe_D_n

Variable containing the current item nominal pipe diameter. This variable contains the nominal diameter in coded units. A special primitive is provided to help you convert from coded units to subunits.

Gen_Type_n

Variable containing the current item end preparation generic type (BLT, MAL, FEM). This is a read-only variable.

Term_Type_n

Variable containing the current item end preparation termination type (21, 22, and 23 will fall into Term_Type_1=20). This is a read-only variable.

Standard_Type

Variable containing the current item standard type value. This is a read-only variable and is a function of TABLE_SUFFIX.

System_Of_Units

Variable defining the current system of measurement. Valid values are ENGLISH and METRIC.

Plant Design System (PDS) Piping Eden Interface

Eden Language Structure

Piping Eden Global Variables Bend_Angle

The bend angle is defined at placement for a component that has a variable sweep angle.

Bend_Radius

The bend radius is defined through the component itself by means of a table lookup.

Bend_Radius_NPD

The bend radius in terms of NPD from the PCD file for the bend component.

Body_OD_n

(n = 1-5) The body outside diameter is the outer diameter of either a bolted, male, or female end of the indicated termination type.

BOLT_DIAMETER BOLT_EXTENSION

Diameter information not used when placing a flanged component. Table lookups are performed during the execution of the MTO process when two mating flanges are found. These keywords are used to hold the data retrieved for the table and then pass on to the MTO process.

Br_Ref_Thick

The branch reinforcement thickness.

Br_Ref_Width

The branch reinforcement width.

Branch_Angle

Used for a table name lookup.

Branch_Table

Identifies the branch insertion table used to determine the name of the branch commodity item to be used for tee and lateral branches.

Commodity_Code

A user-assigned code that together with the NPD and schedule/thickness uniquely defines the component.

CP_Offset_n

(n = 1-5) The connect point offset adjusts the graphics relative to the connect point (for flanges, it adjusts for the gaskets) for female, adjust for penetration. Male is set to zero.

CP_Normal_n

(n = 1-5) The normal vector.

CP_Primary_n

(n = 1-5) The flow centerline vector.

CP_Secondary_n

(n = 1-5) The secondary vector.

CP_to_Origin_n

(n = 1-5) The CP to origin dimension.

Depth_n

(n = 1-4) The connect point depth is the depth of a socket as defined in the table FEM_Term_Rat_TS. It determines a component's dimensional parameters by calculating the depth of the socket minus 1/16 inches.

DIM_TOLERANCE = 1/64 in.

The minimum dimension standards are the minimal values permitted in the Eden program. The minimum distance used for checking connect point separation if 400 units of resolution (USRs), which is approximately equal to 1/5 inch.

Dry_COG

The center of gravity dry.

Dry_Weight

The dry weight.

Plant Design System (PDS) Piping Eden Interface

35

Eden Language Structure Facing_OD_n

(n = 1-5) The facing outside diameter is the outer diameter of either a bolted, male, or female end of the indicated termination type.

F_to_C_Dim_n F_to_F_Dim

(n = 1-5) The face-to-center and face-to-face dimensions retrieve information from a dimension table and pass that information to the database for the appropriate connect point or face to face dimension.

Gasket_Sep_n

(n = 1-5) The gasket separation.

Gen_Flag_Red Gen_Flag_Green

The generic flag retrieves the table suffix for use with table identification.

Geo_Ind_Std

The geometric industry standard is used to define table lengths. The data comes from the piping component data entry.

Insulation

The insulation thickness is defined by the designer at time of pipeline placement. It is used to increase the volume of the interference detection and the display of the Insulation Graphics.

Insulation_n

(n=1 to 4) This variable is used to exclude insulation by connect point.

Item_Name

This variable equates to the model code used in defining a table name.

MIN_CYL_DIA = 1/32 The minimum cylinder diameter permitted in the Eden program. in.

MIN_DIMENSION = 5/8 in.

Hard-coded global variable. The minimum linear dimension value permitted by the Eden program is approximately 1/16 inch.

Min_Weld_Size

The minimum weld size retrieves output from the Branch_Angle/Branch_Table.

Nipple_Length

The nipple length is retrieved from the modifier column in piping component data from the reference database.

36

Plant Design System (PDS) Piping Eden Interface

Eden Language Structure Nom_Bend_Rad

The nominal bend radius. This variable will write to the database and allow reconstruction of the component.

NUMBER_BOLTS

Table lookups are performed during the execution of the MTO process when two mating flanges are found. This keyword is used to hold the data retrieved for the table and then pass on to the MTO process.

Number_Miter

The number of miter joints is the number of miters to be used in a mitered joint. It is retrieved from the modifier column in the piping component data from the reference database.

Number_of_Taps

The number of taps is retrieved from the modifier column in the piping component data from the reference database.

Operator_Orient

Prompts for a secondary orientation of an operator. For example, a handle for a lever or gear operator.

Op_COG

The operator center of gravity.

Op_Weight

The operator weight data referenced from a table and stored in the database.

Or_Port_Size

The orifice port size is defined in the Eden code.

Pipe_OD_n

(n = 1-5) The piping outside diameter.

Seat_Depth_n

(n = 1-5) The seating depth is the depth as defined in the table BLT_Term_RAT_TS. The dimension represents the distance from the outermost surface of the bolted end to the seating surface of the gasket.

Sch_Thick_n

(n = 1-5) The schedule/thickness is the wall thickness of the applicable end of a component of the indicated nominal diameter as defined in the table MALWT_Term_Sc/Th_TS_WC.

Stem_Length

The stem length table lookup/calculated --- stored in database.

Surface_Area

The surface area data referenced from a table and stored in the database.

Symbology

Defines the use of simple or detailed graphics.

Table_Name_A Table_Name_B

Stores the dimension table name.

Table_Name_W

Stores the weight table name.

Thick_Table_Name

Identifies the thickness data table used in piping wall thickness calculations for this piping material class.

Toggle_n

(n = 1-5) Currently used only for valve operations.

Valve_Operator

The valve operator is the value retrieved from the modifier data and tells what valve operator to place.

Weight_Code

Defines the weight code for the component and determines the table to be used in finding the dry weight.

Plant Design System (PDS) Piping Eden Interface

37

Eden Language Structure Wet_COG

The wet center of gravity.

Wet_Weight

The fluid volume weight data referenced from a table stored in the database.

Common Keywords Eden uses keywords for labeling specific values or groups of values. All keywords except TRUE and FALSE can appear as arguments in system-defined primitives (or subroutines). Keywords can be upper or lower case. For consistency, this reference guide displays keywords in upper case. TRUE

Logical true. Used in logical expressions.

FALSE

Logical false. Used in logical expressions.

MALE FEMALE BOLTED

Keywords for generic end preparation.

PRIMARY SECONDARY NORMAL

Keywords used to identify or refer to individual refresh tee axes.

ENGLISH METRIC

Names used to define the units of a constant used in the symbol definition.

Keywords (Piping Specific) The following keywords are specific to the Piping Eden interface.

38

GREEN RED

The spec connect point properties assign connect point properties to a given connect point (that is, end prep, schedule, pressure, table suffix) retrieved from the active material class.

CPn

The connect point numbers.

NULL_GEN_TYPE

The generic term type is used in testing the current end preparation retrieved from the commodity to determine the necessary graphics and dimensions needed to construct the components connection graphics.

THICKNESS_n

(n = 1-5) The fitting CP thickness (flange_depth, thread_depth, or socket_depth) represents the distance from the outermost face of the flange to the back surface of the flange on which the nut rests including any projections on the flange.

NULL_PRESSURE 0 WALL_THICKNESS SCHEDULE CALCULATE

The schedule/thickness and pressure types.

Plant Design System (PDS) Piping Eden Interface

Eden Language Structure STANDARD_TYPE

The standard types are used in building the physical data module name. The keyword STANDARD_TYPE is replaced by one of the following keywords dependent upon the table suffix value found for the commodity being placed. Keyword

Practice

Range

AMS

U.S. Practice

2-99

DIN

European - DIN

100-199

BS

European - British Standard

200-299

EURO_A

European - Practice A

300-399

JIS

International - JIS

400-499

AUS

International - Australian

500-599

EURO_B

European - Practice B

600-699

INT_A

International - Practice A

700-799

INT_B

International - Practice B

800-899

COMPANY

Company Practice

900-999

The geometric standard determines which dimension library to use, such as U.S. Practice or Company Practice. The table suffix determines which physical data definition modules to use to read table data, such as V1_AMS or V1_COMPANY. NPD_SUB_UNITS

The file NPD working units. Test against the keywords ENGLISH or METRIC.

SUBCOMPONENT

The subcomponent name is used to access subcomponents. For example, Subcomponent = 'OP'//Valve_Operator.

FLOW_DIRECTION

The flow direction indicators. FLOW_DIRECTION = TRUE cp1 must be placed at the upstream portion of the pipeline. Generally used on items including check valves. If False or not defined, it is bidirectional.

MODEL

The model symbology types.

ITEM_NAME

The model code data retrieved from the piping commodity data used in building table names.

PHYSICAL_DATA_IDENT

The physical data identification is used to retrieve tag names or numbers for an instrument. It is also used for table lookup dimensions.

Plant Design System (PDS) Piping Eden Interface

39

Eden Language Structure Oper_Dim_A Oper_Dim_B Oper_Dim_C Oper_Dim_D

The operator dimensions keywords allow you to load valve operator dimensions with read/write access into the relational database for piping and instrument components.

NON_RADIAL_BRANCH

The non-radial branch keyword must be used to define the connect point geometry type for non-radial branch components.

ORIFICE_TAP_ORIENTATIO N 0 180 degree orientation ORIFICE_TAP_ORIENTATIO N 1 90 degree orientation

The orifice tap orientation keyword allows relative orientation of two taps on an orifice flange. The use of this keyword is required in conjunction with the Place Component option in Piping Design. The Place Component option places an orifice flange with two taps. These taps are oriented 90 degrees apart versus 180 degrees apart, as specified in the Reference Database.

The dimensions of valve operators vary from supplier to supplier. Typically, valve operators are defined as over-sized in the piping model. Although this is safe with respect to interference checking, it is not always safe with respect to access --- a valve operator may appear to be accessible when it is not. For this reason, these keywords provide the mechanism for four valve operator dimensions to be loaded into the model on the basis of definitions in the Reference Database, such that the data in the model can be reviewed and compared with data for the purchased valves.

You must define the number of taps for the orifice flange in the Piping Commodity Specification Data Table, PDtable_202, of the Material Reference Database. By default, the orifice taps are oriented 180 degrees apart on the outside diameter of the flange, when the modifier column is +2. If you require an orifice flange to have the taps oriented 90 degrees apart, you must specify the modifier column as -2. T80Cn

40

The pipe support data keywords (where n is the applicable column number in the Pipe Support Data Table of the Piping Design Database) allows you to load pipe support data with read/write access into the relational database. This includes updating the pipe support's data when the source of that data is either hard-coded in a Piping Eden module or read from a table in the Physical Data Library.

Plant Design System (PDS) Piping Eden Interface

Eden Language Structure

Comments To place a comment within Piping source code, the comment must be on a separate line from the source line and the exclamation point (!) must be in the first column of the comment line. You cannot place a comment immediately after a call statement (on the same line).

Example Table_Data_Definition 'T_41_420_3000_NREQD_52' ! Description= CL3000 equal tee socketwelded ends weight ! Source= GRINNELL catalog PF-78

Operators Operators are used in conjunction with variables to form expressions. As in FORTRAN, operators can be any one of three types: 1. Arithmetic 2. Relational 3. Logical

Arithmetic Operators Arithmetic operators are used to form arithmetic expressions. These operators follow the mathematical conventions. Valid arithmetic operators include: +

addition

-

subtraction

*

multiplication

/

division

**

exponentiation

//

concatenation using '_'

||

concatenation without using '_'

The first five operators (+, -, *, /, **) can only be used with numeric local and global variables. The concatenation operators (// , || ) can be used with both numeric and string variables. The concatenation operator // is used primarily to form table names. It joins two variables together with an underbar (_) character. The result is a text string.

Example 'ABC' // 'DEF' produces 'ABC_DEF' When using the concatenation operation, real numbers are converted to integers (that is, truncated), then converted to character strings and finally joined together with the underbar character. The concatenation operation is generally used to form messages and character field outputs.

Plant Design System (PDS) Piping Eden Interface

41

Eden Language Structure Example If GEN_TYPE = 20 and PR_RATING = 300, then 'BLT' // GEN_TYPE // PR_RATING // '5' produces 'BLT_20_300_5'

Relational Operators Relational operators are used to form relational expressions that test the value of an Eden expression or establish conditions under which a group of Eden statements can be executed. Valid relational operators include: .EQ.

equal to

.NE.

not equal to

.GE.

greater than or equal to

.GT.

greater than

.LE.

less than or equal to

.LT.

less than

Periods must appear before and after the expression. Relational operators can be used on both numeric and character string variables. However, mixing the two types of operands for a given operation produces computing errors. In character relational expressions, less than means precedes in the ASCII collating sequence, and greater than means follows in the ASCII collating sequence. 'ABCD' .LT. 'ACCD' If two strings in a relational expression are not the same length, the shorter one is padded on the right with spaces until the lengths are equal. 'PQRSTU' .EQ. 'PQR ' 'PQRSTU' .EQ. 'PQR '

Logical Operators Logical operators are used to combine relational expressions into more complex logical expressions. Valid logical operators include: .OR.

logical or

.AND.

logical and Periods must appear before and after the expression.

42

Plant Design System (PDS) Piping Eden Interface

Eden Language Structure

Expressions Expressions are variables, constants, and operators combined to make statements. The format of most Eden expressions is the same as in FORTRAN. Valid expressions include: Replacement

simple arithmetic replacement

Call

executes primitives or subroutines

Do while

execute loop

Indexed Do

execute loop

If - then - else

conditional execution

For every IF statement, there must be an ENDIF statement to end the expression. You can nest up to five If-then-else expressions within an Eden module. For the Replacement, Do while, and If-then-else expressions, you can use parentheses to alter the precedence of calculation.

Replacement Statements Replacement statements are used to set variables or perform calculations. The following list illustrates the various Replacement statements: thickness = 25. vessel_od = DIMENSION_1 test = test + 1 tutor_name = 'EXCH1' table_name = 'BLT' // GEN_TYPE // PR_RATING // '5' dim_a = (dim_b + dim_c) * 2. + dim_d

Call Statement Call statements are used to execute system primitives. The syntax for the Call statement is: Call "primitive" or "subroutine" (argument 1, argument 2, ...)

Example Call Place_Cylinder_With_Capped_Ends (diameter, length)

Do While Statement The Do While statement is used to form indefinite loops. The condition of a Do While statement must equal a logical value (either true or false). The body of the Do While statement will be repeatedly executed as long as the logical expression remains true.

Example The following Do While loop places four cylinders end to end. The pretested loop condition fails on the fifth try (if i equals 4), and control transfers to the message display routine. i = 0 do while (i .LT. 4) i = i + 1

Plant Design System (PDS) Piping Eden Interface

43

Eden Language Structure Call Draw_Cylinder_With_Capped_Ends (diam, leng) enddo Call Display_Message ('Out of loop now')

Indexed Do Statement The Indexed Do statement allows you to form loops that execute a specified number of times. This number is determined by an initial, a terminal, and an incremental parameter of a control variable. The syntax for the Indexed Do statement is: do V = v1, v2, v3 . . . enddo where V

is a control variable (non-string type)

v1 v2 v3

are constants or variables that evaluate to the initial, terminal, and incremental parameters respectively. v3 is optional. If v3 is omitted, the system assumes that the incremental parameter is one. V3 cannot be negative.

Example In this example, I is set to 1. The body of the loop is then executed. I increments by 2 each time the cycle is complete, and the value 3 is checked against the terminator 20. The iteration continues as long as I is less than or equal to 20. When the iteration is greater than 20, the loop ends. do I = 1, 20, 2 . . . enddo

If - then - else Statement If - then - else statements are used when a group of statements is to be conditionally executed. The Eden syntax is the same as FORTRAN syntax. if (condition) then . . . else . . . endif

44

Plant Design System (PDS) Piping Eden Interface

Eden Language Structure Example if (DIMENSION_1 .gt. 24.) then thk = thk + .125 else thk = thk + .250 endif An If statement of the form if (condition) is not valid. In Eden, all If statements must be of the form If (condition) then. The else statement is optional.

Functions Eden provides several functions for performing common mathematical operations. These functions can be used within replacement statements. The following functions must contain the parentheses. DSQRT () square root DABS () absolute value DSINR () sine of an angle in radians DCOSR () cosine of an angle in radians DTANR () tangent of angle in radians DSIND () sine of an angle in degrees DCOSD () cosine of an angle in degrees DTAND () tangent of an angle in degrees DASINR () arcsine returned in radians DACOSR () arccosine returned in radians DATANR () arctangent returned in radians DASIND () arcsine returned in degrees DACOSD () arccosine returned in degrees DATAND () arctangent returned in degrees

Example The following list illustrates a few possible Eden functions: length = hypot * DSIND (30.) side = DTANR (pi/2) + 32. hypot = DSQRT (a**2 + b**2) angle = DATAND (side1/side2)

Plant Design System (PDS) Piping Eden Interface

45

Eden Language Structure

Primitives Primitives are system-defined routines that perform specific functions for symbol definition. Convert NPD to Subunits (on page 46) Define Active Orientation (on page 47) Draw Cone (on page 48) Draw Cylinder (on page 49) Draw Eccentric Cone (on page 49) Draw Projected Rectangle (on page 50) Draw Projected Triangle (on page 51) Draw Semi-Ellipsoid (on page 51) Draw Sphere (on page 52) Draw Torus (on page 53) Assign Connect Point (on page 53) Assign Generic Tap (on page 54) Assign Tap (on page 54) Compute Perpendicular Vector (on page 55) Define Connect Point Geometry (on page 55) Display Tutorial (on page 56) Draw Cone With Capped Ends (on page 57) Draw Cylinder With Capped Ends (on page 57) Draw Eccentric Cone With Capped Ends (on page 58) Draw Hexagon (on page 59) Draw Mitered Torus (on page 59) Draw Octagon (on page 60) Draw Parametric Shape (on page 61) Draw Torus With Capped Ends (on page 61) Get Physical Data (on page 62) Move Along Axis (on page 63) Move By Distance (on page 63) Move To Connect Point (on page 64) Place COG Location (on page 64) Place Connect Point (on page 65) Prompt to Orient Operator (on page 65) Read Table (on page 65) Rotate Orientation (on page 66)

Convert NPD to Subunits The Convert NPD to Subunits primitive converts the coded input value and returns its Real*8 equivalent. This primitive is often used for converting the nominal piping diameter that is stored in the database. Metric files base the diameter in millimeters. Imperial files store the nominal piping diameter as NPD 1/32 + 5000. Thus, 1 inch NPD is 5000 + 32 * 1 = 5032 20 inch NPD is 5000 + 32 * 20 = 5640 For Eden symbols in Piping that use imperial and metric files, hard-coding the dimensions is not recommended. A dimension entered as 5 inches and placed in an Imperial file is interpreted as 5 inches. However, the same value placed in a Metric file is interpreted as 5 millimeters. Instead of hard coding, load the dimensions in a table to allow the piping software to convert the dimensions to the correct values.

46

Plant Design System (PDS) Piping Eden Interface

Eden Language Structure This primitive does not perform unit conversions. If American standard pipe sizes are being used in a Metric file, this primitive will return the NPD in inches.

Syntax Call Convert_NPD_To_Subunits (coded_input, npd)

Options coded_input

The nominal pipe diameter in internal or coded units. This variable must be the keyword Nom_Pipe_D_n.

npd

The nominal piping diameter in subunits.

Examples In this example, the Real*8 equivalence of the coded NPD in Nom_Pipe_D_1 is returned in Pipe_Dia_1. Call Convert_NPD_To_Subunits (Nom_Pipe_D_1, pipe_dia_1) All NPDs used internally in the software are in encoded form. Most table lookups based on NPDs require the input to be in encoded form. However, if a nozzle size is needed in a calculation, it must be converted from internal units to subunits.

Define Active Orientation The Define Active Orientation primitive allows you to define the active orientation by specifying the directions of the primary and secondary axes. The orientation is defined in the local coordinate system by the symbol. This definition has no bearing on the design file coordinate system. In Piping, this primitive defines the current flow centerline and a direction that is normal to the flow centerline in terms of the connect point orientation (defined by the symbol's connect point geometry) in order to place graphic shapes.

Specific keywords are available for specifying either the primary axis or the secondary axis of the connect point's orientation.

Syntax Call Define_Active_Orientation (primary, secondary)

Options primary

Variable that defines the flow centerline or primary direction.

secondary

Variable that defines the line perpendicular to the flow centerline or secondary direction. Valid keywords for the primary and secondary variables include: CP_PRIMARY_n

Plant Design System (PDS) Piping Eden Interface

47

Eden Language Structure CP_SECONDARY_n CP_NORMAL_n For the Piping keywords, n is the connect point number. If the initial active orientation for a symbol definition has the primary pointing east and the secondary pointing north, the normal axis of the active orientation would be up. (Normal axis can be found using the right-hand rule.)

Restrictions  

In Piping, you must have already called Place Connect Point (CPn). For operator, initial point of operator is assumed CP1. In Piping, the two variables used must have the same connect point number.

Example In the following example, the secondary orientation at connect point 2 becomes the new active primary orientation at the active point, and the primary orientation at connect point 2 becomes the active secondary. Call Define_Active_Orientation (CP_Secondary_2, CP_Primary_2)

Draw Cone The Draw Cone primitive places a cone where the first end is at the current active point and the second end is at a location computed by the system given the input length along the primary axis. You must define the diameters of each end of the cone with separate variables.

Syntax Call Draw_Cone (length, diameter_1, diameter_2)

Options

48

length

The length of the cone (A), which can be positive or negative.

diameter_1

The diameter of the cone (B) at the active point.

diameter_2

The diameter of the cone (C) at the end opposite the active point.

Plant Design System (PDS) Piping Eden Interface

Eden Language Structure

Draw Cylinder The Draw Cylinder primitive places a cylinder where the first end is at the current active point and the second end is at a location computed by the system along the primary axis. You must specify the diameter and the length of the cylinder. The active point will be moved to the opposite end.

Syntax Call Draw_Cylinder (length, diameter)

Options length

The length (A) of the cylinder.

diameter

The diameter (B) of the cylinder.

If cyl_len is positive, a cylinder of the specified length is drawn. If cyl_len is zero, nothing happens. If cyl_len is negative, the active point is moved the specified negative distance, but the cylinder is not drawn.

Draw Eccentric Cone The Draw Eccentric Cone primitive allows you to place an eccentric truncated cone. The first end is at the current active point. The second end is at a location the system computes by moving from the current active point along the current flow centerline by the length of the cone and along the secondary axis by the negative of the eccentric offset. You must specify the eccentric offset and the diameters of both ends of the eccentric cone.

Syntax Call Draw_Eccentric_Cone (length, eccentric_offset, diameter_1, diameter_2)

Plant Design System (PDS) Piping Eden Interface

49

Eden Language Structure Options length

Cone length (A).

eccentric_offset

Eccentric cone offset. This is the center-to-center distance between cone endpoints as measured positive going against the secondary.

diameter_1

Diameter (B) at active point.

diameter_2

Diameter (C) at the opposite end.

Draw Projected Rectangle The Draw Projected Rectangle primitive allows you to place a component with a rectangular cross section. The current active point must be moved to the center of the rectangle, and the primary axis must point in the direction of the projection. The secondary axis orients the side of length1.

You must specify the projected height, projected width, and projected length dimensions.

Syntax Call Draw_Proj_Rectangle (length1, length2, projection)

Options length1

Length of the rectangle side (C) parallel to the secondary axis of the active orientation.

length2

Length of the rectangle side (B) parallel to the normal axis of the active orientation.

projection

Length of the projection (A).

Restrictions  

50

The active point must be located at the center of geometric shape of the rectangle. The refresh tee must point inward (the direction of projection).

Plant Design System (PDS) Piping Eden Interface

Eden Language Structure

Draw Projected Triangle The Draw Projected Triangle primitive allows you to place a component that has an isosceles triangular cross-section. The current active point must be moved to the center of the cross-section. The primary axis points in the direction of the projection, and the secondary axis points to the base of the triangle. You must specify the side length, base length, and projected length dimensions.

Syntax Call Draw_Proj_Triangle (project_side_length, project_base_length, project_length)

Options project_side_length

Length of the side (A) of the triangle.

project_base_length

Length of the base (B) of the triangle.

project_length

Length of the projection (C).

Restrictions  

The active point must be located at the center of geometric shape of the triangle. The refresh tee must point inward. Make sure that dimension A is greater than 1/2 of dimension B, otherwise, errors will

result.

Draw Semi-Ellipsoid The Draw Semi-Ellipsoid primitive allows you to place a semi-ellipsoid, where the center is at the current active point. You must specify the diameter of the major axis and the radius of the minor axis.

Plant Design System (PDS) Piping Eden Interface

51

Eden Language Structure The system does not update to a new active orientation after placement of the semi-ellipsoid.

Syntax Call Draw_Semi_Ellipsoid (major_axis_diameter, minor_axis_radius)

Options major_axis_diameter

Variable defining the major axis diameter (A).

minor_axis_radius

Variable defining the minor axis radius (B).

Draw Sphere The Draw Sphere primitive allows you to place a sphere where the center of the sphere is at the current active point. You must specify the radius, and the radius must be greater than or equal to () 1/64 inches. The refresh tee and orientation will not change after placement.

Syntax Call Draw_Sphere (radius)

Options radius

52

Variable (A) defining the sphere radius.

Plant Design System (PDS) Piping Eden Interface

Eden Language Structure

Draw Torus The Draw Torus primitive allows you to place a torus from the current flow centerline to the current direction of the secondary axis using the bend radius, bend angle, and diameter you specify. This call changes the active orientation.

The torus diameter must be greater than or equal to () 1/32 inches, and the bend radius diameter must be greater than or equal to () 1/32 inches and greater than (>) 1/2 the torus diameter.

Syntax Call Draw_Torus (radius, angle, diameter)

Options radius

The bend radius of the torus (B) as measured from the origin of the torus to its centerline.

angle

The bend angle of the torus (C).

diameter

The diameter of the torus (A).

Assign Connect Point The Assign Connect Point primitive allows you to assign the connect point data for one color (GREEN or RED) in the Piping Job Specification to a pressurized connect point. This primitive assigns to connect points the properties in the specification associated with the color assigned with the connect point.

Syntax Call Assign_Connect_Point (color, CPn)

Options color

RED - small line size. GREEN - large line size.

CPn

Connect point number.

Plant Design System (PDS) Piping Eden Interface

53

Eden Language Structure Restrictions  

One component can have up to five connect points including up to two tap points, for a total of five connect points per component. You must assign all the connect points for a component before you call the physical data routine. Once you make another call, Eden assumes that there are no more connect points associated with the symbol. Any connect points assigned after the subroutine call are considered illegal. To ensure that the connect points are assigned before another call is made, place the call to assign connect points in the beginning of the Symbol Processor module.

Examples 

The following example assigns GREEN properties to connect point 1. Call Assign_Connect_Point (GREEN,CP1)



The following example assigns RED properties to connect point 2. Call Assign_Connect_Point (RED, CP2)

Assign Generic Tap The Assign Generic Tap primitive allows you to assign a connect point as a tap, but still to go to the spec for connect point properties instead of the Tap Properties Table. This routine is needed because of limited connect point geometry types in ISOGEN. Refer to the ISOGEN Interface User's Guide for more information. This primitive should be used only for speciality items.

Syntax Call Assign_Generic_Tap (cp_type, CPn)

Options cp_type

GREEN or RED

CPn

Connect point number.

Example The following example assigns GREEN properties to connect point 4, but is by definition a tap. Call Assign_Generic_Tap (GREEN, CP4)

Assign Tap The Assign Tap primitive allows you to define a pressurized connect point as a tap. The system uses the nominal piping diameter you specified for the tap and the connect point data from the Tap Properties Table of the Piping Job Specification.  

The Assign Tap command applies only to components that have the geometry type of ORIFICE_FLANGE. You must assign all connect points and the tap_diameter before assigning a tap.

Syntax Call Assign_Tap (tap_diameter, CPn)

54

Plant Design System (PDS) Piping Eden Interface

Eden Language Structure Options tap_diameter

Diameter of the tap.

CPn

Connect point number.

Example The following example assigns a tap at connect point three with a diameter of two inches. tap_diameter = 2.0 Call Assign_Tap (tap_diameter, CP3)

Compute Perpendicular Vector The Compute Perpendicular Vector primitive computes orientation vectors where the primary axis is perpendicular to the primary vector of connect point 1 and in the plane of the secondary axis, and the new secondary is in the same direction as the primary of connect point 1. This is used mainly for RWELDS and RPADS so that the cylinder is flat on the pipe. You can use any unused connect point for storage. All connect points should be placed before this computed orientation is used because this could cause a problem when connect point geometry is checked at placement time.

Syntax Call Compute_Perpendicular_Vector (CPn, CP_Primary_n, CP_Secondary_n)

Options CPn

Connect point number (stored temporarily).

CP_Primary_n

Variable used to store computed primary.

CP_Secondary_n

Variable used to store computed secondary.

Example Call Call Call Call

Compute_Perpendicular_Vector (CP5, CP_Primary_5, CP_Secondary_5) Move_By_Distance (f_to_c_dim_1) Define_Active_Orientation (CP_Primary_5, CP_Secondary_5) Draw_Cylinder (length, diameter)

Define Connect Point Geometry The Define Connect Point Geometry primitive allows you to define the connect point geometry from the component being placed. Specific keywords are available for specifying the type of connect point geometry. Connect point geometry is used at placement time to determine that all connect points are correct. Using Define Connect Geometry, you can define the orientation for each connect point and check that the correct number of connect points have been defined.

Syntax Call Define_Connect_Point_Geometry (geometry_type)

Plant Design System (PDS) Piping Eden Interface

55

Eden Language Structure Options geometry_type

Name of specific geometry of symbol. Valid geometries include: LINEAR

CROSS OPERATOR

ELBOLET

LATROLET

BEND

OLET

ANGLE_VALVE

SINGLE

ECC_REDUCER

SINGLE_CP

BRANCH_TEE

RET_180

BRANCH_LAT

ORIFICE_FLANGE

BRANCH_WYE

GENERIC_COMPONENT

BRANCH_2WYE

NON_RADIAL_BRANCH OPERATOR

Restrictions   

Each component can have only one geometry type. The number of connect points for the geometry type defined here must match the number in the Symbol Processor module. The geometry type is limited to the possible geometries associated with the component being placed.

Example The following example calls the connect point geometry for a bend that tests to see that all connect points are defined for a bend geometry type. Call Define_Connect_Point_Geometry (BEND)

Display Tutorial The Display Tutorial primitive allows you to display a tutorial from within an Eden module in order to obtain dimensions from the user key-ins. This routine should not be called in Interference Graphics modules.

Syntax Call Display_Tutorial (Tut_Name)

Options Tut_Name

The form as it appears in the forms directory. You are limited to six characters.

Example In this example, the tutorial for operator 33C dimensions is displayed. You can now enter the needed dimensions. Call Display_Tutorial ('VOP33C')

56

Plant Design System (PDS) Piping Eden Interface

Eden Language Structure

Draw Cone With Capped Ends The Draw Cone With Capped Ends primitive allows you to request the placement of a cone with capped ends, where the first end is at the current active point and the second end is at a location computed by the system.

Syntax Call Draw_Cone_With_Capped_Ends (length, diameter_1, diameter_2)

Options length

Variable (A) that defines the length of the cone.

diameter_1

Variable (B) that defines the diameter at the active point.

diameter_2

Variable (C) that defines the diameter at the opposite end of the of the cone.

Example A = 5 B = 2 C = 1 Call Draw_Cone_With_Capped_Ends (A, B, C)

Draw Cylinder With Capped Ends The Draw Cylinder With Capped Ends primitive allows you to place a cylinder with capped ends, where the first end is at the current active point and the second end is at a location computed by the system. You must specify the diameter of the cylinder and the length.

Syntax Call Draw_Cylinder_With_Capped_Ends (length, diameter)

Options length

Variable (A) defining the cylinder length.

Plant Design System (PDS) Piping Eden Interface

57

Eden Language Structure diameter

Variable (B) defining the cylinder diameter.

Example The following example draws a cylinder with a length of 5.0 and a diameter of 1.0. If cyl_len is positive, a cylinder of the specified length is drawn. If cyl_len is zero, nothing happens. If cyl_len is negative, the active point is moved the specified negative distance, but the cylinder is not drawn. A = 5.0 B = 1.0 Call Draw_Cylinder_With_Capped_Ends (A, B)

Draw Eccentric Cone With Capped Ends The Draw Eccentric Cone With Capped Ends primitive allows you to place an eccentric truncated cone with capped ends. The first end is at the current active point. The second end is at a location the system computes by moving from the current active point along the current flow centerline by the length of the cone and along the secondary axis by the negative of the eccentric offset. You must specify the eccentric offset and the diameters of both ends of the eccentric cone.

Syntax Call Draw_Eccentric_Cone_With_Capped_Ends (length, offset, diameter_1, diameter_2)

Options length

Variable (A) defining the cone length.

offset

Variable defining the eccentric cone offset.

diameter_1

Variable (B) defining the diameter at the active point.

diameter_2

Variable (C) defining the diameter at the opposite end.

Example A = F_to_f_Dim - Thickness_1 - Thickness_2 offset = 0.5 * (C - B) Call Draw_Eccentric_Cone_With_Capped_Ends (A, offset, B, C)

58

Plant Design System (PDS) Piping Eden Interface

Eden Language Structure

Draw Hexagon The Draw Hexagon primitive draws a hexagon of the specified length and depth.

Syntax Call Draw_Hexagon (length, depth)

Options side_length

Side B is the side length.

proj

Side A is the length of the projection.

Example The following example draws a hexagonal shape with the specified diameter and depth. A = Dimension_2 B = Dimension_3 Call Draw_Hexagon (B, A)

Draw Mitered Torus The Draw Mitered Torus primitive allows you to place a mitered torus. The system emulates the mitered torus by placing cylinders representing miters. You must must specify the number of miters. The diameter must be greater than or equal to () 1/32 inches, and the bend radius must be greater than or equal to () 1/2 the diameter.

Syntax Call Draw_Mitered_Torus (radius, angle, diameter, number)

Plant Design System (PDS) Piping Eden Interface

59

Eden Language Structure Options radius

Variable (A) defining the torus bend radius.

angle

Variable (B) defining the torus bend angle.

diameter

Variable (C) defining the torus diameter.

number

Number of cuts to generate a miter.

Example The following example draws a torus with the bend radius, bend angle, and diameter equal to the outside diameter of the body at connect point 1. A = bend_radius B = bend_angle C = body_OD_1 Call Draw_Mitered_Torus (A, B, C, 2)

Draw Octagon The Draw Octagon primitive allows you to draw an octagon of the specified width and depth.

Syntax Call Draw_Octagon (width, projection)

Options width

Distance (A) between the two opposite sides.

projection

Depth (B) of shape.

Example The following example draws an octagonal shape given the width and depth. A = Dimension_2 B = Dimension_3 Call Draw_Octagon (A, B)

60

Plant Design System (PDS) Piping Eden Interface

Eden Language Structure

Draw Parametric Shape The Draw Parametric Shape primitive allows you to reference a user-defined module that draws the graphics for the parametric shape of the component being placed. The module name is limited to a maximum of 28 characters. You must assign the appropriate graphic name to the parametric shape that you want to draw.

Syntax Call Draw_Parametric_Shape (parametric_shape)

Options parametric_shape

Name of the module that you defined to draw the graphics. The name must be set before calling the module.

Example The following example calls the module that places the graphics, connect points, and so forth for parametric shape F47. parametric_shape = 'F47' Call Draw_Parametric_Shape (parametric_shape) OR Call Draw_Parametric_Shape ('F47')

Draw Torus with Capped Ends The Draw Torus with Capped Ends primitive allows you to place a torus with capped ends from the current flow centerline to the current direction of the secondary axis using the bend radius, bend angle, and the diameter you specify.

The diameter must be greater than or equal to () 1/32 inches and the bend radius diameter must be greater than or equal to 1/32 inches and > 1/2 torus diameter.

Syntax Call Draw_Torus_with_Capped_Ends (radius, angle, diam)

Plant Design System (PDS) Piping Eden Interface

61

Eden Language Structure Options radius

Variable (B) defining the bend radius.

angle

Variable (C) defining the angle of the torus.

diam

Diameter (A) of the torus.

Example The following example draws a torus with capped ends with a radius equal to the bend radius, at an angle equal to the active bend_angle, with a diameter equal to the outside diameter of the body at connect point 1. Call Draw_Torus_with_Capped_Ends (bend_radius, bend_angle, body_OD_1)

Get Physical Data The Get Physical Data primitive allows you to reference a user-defined module or user-selected standard (Metric or English) that defines the physical data for the component being placed. The name of the module must be less than or equal to () 28 characters. Set the physical data source variable equal to the name of the physical data module you are calling.

Syntax Call Get_Physical_Data (physical_data_source)

Options physical_data_source

Name of the physical data module set previous to this primitive.

Examples

62



The following example sets the variable physical_data_source to F47_AMS and then calls the routine which accesses the physical data: physical_data_source = 'F47' // STANDARD_TYPE Call Get_Physical_Data (physical_data_source)



The following example sets a variable named physical_data_source to F47_AMS and then calls the routine which accesses the physical data: physical_data_source = 'F47_AMS' Call Get_Physical_Data (physical_data_source)



The following example calls the routine which accesses the physical data without defining a variable for the physical data source: Call Get_Physical_Data ('F47_AMS')

Plant Design System (PDS) Piping Eden Interface

Eden Language Structure

Move Along Axis The Move Along Axis primitive allows you to move a specified distance along a specified axis. It is useful for symbols such as olets that do not have graphics that start at the point of connection.

Syntax Call Move_Along_Axis (distance, axis)

Options distance

Negative or positive distance to move.

axis

Axis to move along: PRIMARY, SECONDARY, or NORMAL.

Examples In this example, after obtaining radius of pipe and diameter of cylinder, move along the active secondary axis to the edge of the pipe and place cylinder graphics for an olet. cyl_diam = Dimension_1 radius = (Dimension_2 - cwht) + 0.5 Call Move_Along_Axis (-radius, SECONDARY) Call Draw_Cylinder (radius, cyl_diam)

Move By Distance The Move By Distance primitive allows you to move from the current active point along the current flow centerline by a distance (positive or negative). The distance you specify must be a real number in floating point form.

Syntax Call Move_By_Distance (distance)

Options distance

Variable name for the distance along the flow centerline.

Examples 

The following example moves the active point by a distance equal to the offset of connect point 2: Call Move_By_Distance (CP_Offset_2)



The following example moves the active point by a distance equal to the face to center dimension for connection point 2 and in the opposite direction: Call Move_By_Distance (-F_to_C_Dim_2)

Plant Design System (PDS) Piping Eden Interface

63

Eden Language Structure

Move To Connect Point The Move To Connect Point primitive allows you to move from the current active point to the location of a connect point that has been previously placed in the symbol description. The connect point assumes the orientation of the new connect point location. You must call the Place Connect Point primitive before calling Move_To_Connect_Point.

Syntax Call Move_To_Connect_Point (CPn)

Options CPn

Variable defining the connect point number (n = 0,1,2,3,4,5).

Example In the following example, the call moves the active point to connect point 1: Call Move_To_Connect_Point (CP1)

Place COG Location The Place COG Location primitive allows you to define the location of the center of gravity for either dry or wet (operational) conditions. Specific keywords are available for specifying the basis for the center of gravity location. When you call this subroutine, the system assigns the COG_Type to the Active_Point location.

Syntax Call Place_COG_Location (COG_type)

Options COG_type

Variable defining the center of gravity type.

Examples The following examples display the three types of centers of gravity: Call Place_COG_Location (DRY_COG) Call Place_COG_Location (WET_COG) Call Place_COG_Location (OP_COG)

64

Plant Design System (PDS) Piping Eden Interface

Eden Language Structure

Place Connect Point The Place Connect Point primitive allows you to define the location and the orientation of the component center, a pressurized connect point, or a tap and place that point. Specific keywords are available for specifying the connect point identification of the component center, the pressurized connect point or the tap. When you call Place Connect Point, the location of the Active_Point is assigned to the connect point. You must place all of the connect points that were assigned in the symbol processor module.

Syntax Call Place_Connect_Point (CPn)

Options CPn

Variable defining the connect point (n = 0,1,2,3,4,5).

Example The following example places a connect point at the current location with current orientation: Call Place_Connect_Point (CP0)

Prompt to Orient Operator The Prompt to Orient Operator primitive allows you to prompt the operator to orient a valve operator. This request is only required for non-symmetrical valves, where the secondary axis cannot be used to define the valve operator orientation. The message for the prompt is determined by referencing a message in the PDS Piping Design Message Library. Do not call this primitive from the interference checking modules.

Syntax Call Prompt_to_Orient_Operator (prompt)

Example Prompt = 1.0 Call Prompt_to_Orient_Operator (prompt)

Read Table The Read Table primitive allows you to read data from a table in the Piping Job Spec Table Library or Dimension Table Library. Call this primitive from the Physical Data Definition module. Refer to the Reference Data Manager (PD_DATA) Reference Guide for information on the valid naming formats for tables and the valid units that can be used in tables. Use the input and output arrays that are defined in the Data Dictionary. Table names are limited to 46 characters. You must assign input values before using this primitive; otherwise, the system sets the input values to zero. The syntax for the Read Table primitive is: Call Read_Table (table_name, input, output)

Plant Design System (PDS) Piping Eden Interface

65

Eden Language Structure Options table_name

Variable defining the table name.

input

Variable defining the input used to access data in the table. This variable ranges from input_1 to input_10.

output

Variable defining the output read from the table. The variable range is from output_1 to output_8.

Example The following example sets the global variable, Table_Name_A, equal to the name of the table to be called, then sets input_1 equal to the nominal pipe diameter at connect point 1 and input_2 to the nominal pipe diameter at connect point 2, and then calls the routine that reads the output from the table. The face to center dimension is output 3 from the table read. You do not need to put the underbar in the table name. Concatenation inserts the underbar when forming the table names. Table_Name_A = Item_Name // Geo_Ind_Std // Term_Type_1 Input_1 = Nom_Pipe_D_1 Input_2 = Nom_Pipe_D_3 Call Read_Table (Table_Name_A, input, output) F_to_C_Dim_1 = Output_3

Rotate Orientation The Rotate Orientation primitive allows you to rotate the active orientation about any axis and with any angle.

Syntax Call Rotate_Orientation (angle, axis)

Options angle

Angle of rotation in degrees.

axis

Axis of rotation: primary, secondary, or normal.

Example In the following example, after the primitive is executed, the primary and normal are rotated 90 degrees about the secondary axis: Call Rotate_Orientation (angle, SECONDARY)

66

Plant Design System (PDS) Piping Eden Interface

Eden Language Structure

Connect Point Geometry The following is a list of connect point geometries for specific piping components:  A reducing component with two connect points, such as a reducer or a reducing bend, must be defined by the convention that the nominal piping diameter at connect point one is the larger of the two nominal piping diameters.  By PDS definition, flanges should be defined in the Piping Graphic Commodity Library with the green connect point representing the flanged connect point and the red connect point representing the non-flanged connect point.  By PDS definition, for a symmetrical valve, the primary axis of the Refresh Tee determines the centerline of the valve body, and the secondary axis determines the centerline of the valve's operator (if there is an operator in the symbol definition). If the valve body is non-symmetrical and the secondary axis is needed to orient the valve body, the user must be prompted in the symbol definition to orient the centerline of the valve operator. The following list contains connect point geometry keywords, their definitions and example diagrams. You must define the connect point geometry type before placing any connect points. LINEAR

Any component that has all connect points along one vector, such as a gate valve or a weld-neck flange.

ELBOLET

Elbolets or any component that has a tap that lies along the same vector as the one formed by CP1 and CP0 or CP2 and CP0.

Plant Design System (PDS) Piping Eden Interface

67

Eden Language Structure

68

BEND

Direction-change components where the angle of change is not necessarily 90 degrees.

ANGLE_VALVE

Valves that have a 90 degree direction change.

ECC_REDUCER

Eccentric Reducing components. The connect points are offset along the secondary axis. The vectors coming into and leaving the component remain parallel.

BRANCH_TEE

Branch component where CP1 and CP2 are along the same primary vector. CP3 is along the vector of the secondary.

Plant Design System (PDS) Piping Eden Interface

Eden Language Structure

BRANCH_LAT

Branch component that has the branch leg coming off at a variable angle from the primary. CP1 and CP2 are along the primary, and CP3 is along the secondary.

BRANCH_WYE

Branch component where CP1 is on the primary axis; CP2 and CP3 are both on vectors that are offset from the primary vector by 45 degrees in either direction. The vectors created by CP2 and CP0 or CP3 and CP0 are perpendicular.

BRANCH_2WYE

A 4-connect-point branch that has the same general layout as the BRANCH_WYE, but instead of the line splitting off in two directions, a third line continues on the flow centerline.

Plant Design System (PDS) Piping Eden Interface

69

Eden Language Structure

70

CROSS

A 4-connect-point branch that is formed on 2 perpendicular vectors. CP0 is where the 2 vectors cross.

OPERATOR

Any item that does not have connect points. Operators have no connect points.

LATROLET

Olets that can be placed at a variable angle to the primary or flow LATROLETcenterline, such as reinforcing pads and reinforcing welds.

Plant Design System (PDS) Piping Eden Interface

Eden Language Structure

OLET

Olets that are perpendicular to the flow centerline.

SINGLE_CP

Items with 1-connect-point, such as a cap.

RET_180

U-shaped components that must be 180 degrees.

Plant Design System (PDS) Piping Eden Interface

71

Eden Language Structure

ORIFICE_FLANGE

Linear component that has 1 or 2 taps that are perpendicular to the flow centerline.

GENERIC_COMPONENT

Specialties, instruments, and pipe supports where the geometry is not rigidly defined (Not to be used with piping components).

The refresh tee must point inwards (to CP0) before you define each connect point (CP#). Not all geometric configurations associated with this type may be defined for ISOGEN.

72

Plant Design System (PDS) Piping Eden Interface

SECTION 4

Creating a New Piping Component Eden Setup Before a new piping component can be defined through Eden, follow these steps: 1. Create a directory path for symbol definition files  Log in to the server where the PDS project resides.  Create a piping symbols directory. If the new components will be shared by two or more projects, the new directory could look like this: c:\users\default\projects\custom\pipesym where custom is an optional directory where customized libraries and symbol definition directories for all projects can be kept.  If the customized libraries and components will be specific to one project, the following alternative can be used: c:\users\default\projects\proj1\pipesym where proj1 is the directory of an existing project. 2. Create a directory path for dimension and spec tables.  Log in to the server where the PDS project resides.  Create the dimension and spec tables directory. c:\users\default\projects\custom\tbls OR c:\users\default\projects\proj1\tbls 3. Create a directory path for graphic data and table libraries, and copy them into this directory.  Log in to the server where the PDS project resides.  Create a library directory. c:\users\default\projects\custom\libs OR c:\users\default\projects\proj1\libs  Copy the standard delivered libraries into the library directory. copy c:\win32app\ingr\rdusrdb\*.l* c:\users\default\projects\custom\libs\ copy c:\win32app\ingr\pdshell\lib\*.l* c:\users\default\projects\custom\libs\ OR copy c:\win32app\ingr\rdusrdb\*.l* c:\users\default\projects\proj1\libs\ copy c:\win32app\ingr\pdshell\lib\*.l* c:\users\default\projects\proj1\libs\ If working in a non-U.S. standards project, substitute rdusrdb with the rdb being used. 4. Access the Reference Database Defaults form and enter the node name and path to the directories previously defined.

Plant Design System (PDS) Piping Eden Interface

73

Creating a New Piping Component     

Access the pdshell form. Select a project from the form. Select the Reference Data Manager option. Select the Default Project Control Data option. Enter the path and node name to the directories previously created. Piping Eden Path: c:\users\default\projects\custom\pipesym\ Piping Eden node: Dim/Spec Table Path: c:\users\projects\custom\tbls\ Dim/Spec Table node:



Make sure that the Piping Spec definitions are specified. If a U.S. standards project is being used, the following data should appear: Piping Spec Path: c:\win32app\ingr\rdusrdb\spec_data\ Piping Spec node: If working in a non-U.S. standards project, substitute rdusrdb with the rdb being used.

A detailed description of the Default Project Control Data option is provided on the next few pages. 5. Access the Reference Database Management Data form, and define the node name and directory path to the graphic data and table libraries. When testing new libraries in a live project, it is recommended to enter them as "Not Approved."  Select Cancel on the Defaults form.  Select the Reference Database Management Data option.  Select the Default All Library Locations, and enter the library directory previously created. Network Address: Directory: c:\users\default\projects\custom\libs 

  

74

Make sure that the specifications are correct for each library (some of the default values are incorrect). The following specifications are used for a U.S. standards project: Piping Job Spec Table

us_pjstb.l

Short Matl Description

us_shbom.l

Long Matl Description

us_lgbom.l

Specialty Matl Description

us_spbom.l

Standard Note

std_note.l

Label Description

labels.l

Piping Assembly

assembly.l

Graphic Commodity

pip_gcom.l

Physical Data - U.S. Practice

us_pcdim.l

If working in a non-U.S. standards project, see the rdb directory being used to find the correct specifications. To revise an entry, follow these steps: Identify the library to be checked. Place the cursor at the beginning of the "Specification" field. Delete to the right of the cursor.

Plant Design System (PDS) Piping Eden Interface

Creating a New Piping Component  

Enter the correct value and press the Enter key. Accept the form.

A detailed description of the Reference Database Management option is provided on the next few pages.

Reference Database Management Data This option activates the Reference Database Management Data form used to define the file names for Reference Database Files, graphic commodity data, dimension tables, and spec tables. You can define both approved or unapproved RDB data for each item.

Operating Sequence 1. Select Reference Database Management Data from the Reference Data Manager form.

2. Select RDB File Type Select the RDB file from the list of files. You can use the scroll arrows to scroll through the listed files.

The system identifies the file for the selected field in the fields at the bottom of the form. There are no default settings for these files; you must define the applicable file locations before you can continue. 

 

Material/Specification Reference Database — This field identifies the Material Reference Database for the project. Refer to the Project Setup Manager in the Project Administrator Reference Guide for more information on this database. Piping Job Specification Tables Library — This field identifies the location of the Piping Job Spec Table library. Short Material Description Library — This field identifies the library which contains the short bill-of-material description for all piping commodity items and the BOM description addenda for taps.

Plant Design System (PDS) Piping Eden Interface

75

Creating a New Piping Component Long Material Description Library — This field identifies the library which contains the long BOM description for all piping commodity items. The long BOM description is only used for requisitions.  Specialty Material Description Library — This field identifies the library which contains the BOM description for engineered items, in-line instruments, and pipe supports. This library tends to be customer-specific.  Standard Note Library — This field identifies the location of the standard note library.  Label Description Library — This field identifies the location for the label description library.  Piping Assembly Library — This field identifies the location for the Piping Assembly library. This library contains the symbol definitions for assemblies.  Graphic Commodity Library — This field identifies the library which contains the Eden modules used to place components in the model.  Physical Data Tables Library — These fields identify the library files which contain the physical data tables for a range of geometric industry standards.  Commodity Synonym Library — This field identifies the user-defined library which contains the map for translating the default piping commodity names used in the P&ID Task to names specified by the user in the Piping Job Specification.  Orthographic Drawing Borders — This field identifies the drawing border files to be used when creating drawings. A set of border files are delivered to the directory win32app\ingr\pddraw\border. You must specify which style of borders is to be used. Key in any changes to the selected RDB files. Refer to Delivered Reference Data for a listing of the delivered reference data files. If you specify an unapproved file, the system will use the unapproved file for all Reference Data Manager operations (such as revising entries in a library.) Refer to the Project Data Manager in the Project Administrator Reference Guide for information on setting the choice of data for a model file or drawing. You can select Approved --> Not Approved to copy the approved definition of the selected RDB file to the Not Approved fields. Select confirm to update the information. Refer to the individual managers for information on posting the unapproved information to the approved files. You can select Default All Library Locations to define a default location for all approved and all unapproved library files. You can select Copy All Standard Libraries to copy the delivered library files to a specified location. Select Accept following each change to the reference data to accept the specified file location. — THEN — Select Cancel to exit the form. 

3.

4.

5. 6. 7.

Default All Library Locations This option assigns a default network address, pathname, and file specification to the various Reference Database libraries for both the approved and unapproved libraries. You can override any of these default specifications by selecting the appropriate library and keying in the file information.

76

Plant Design System (PDS) Piping Eden Interface

Creating a New Piping Component Specify Default Nodename Key in a default network address and pathname to be used for all approved Reference Database libraries and a network address and pathname to be used for all unapproved libraries. The file specifications for all libraries are determined automatically on the basis of the industry practice and the following naming convention. When copying the Not Approved library to the Approved library, the copy will not occur if the approved library is the most recent or has the same date as the unapproved library. Library

File name

Graphic Commodity Library

pipe_gcom.l

Label Description Library

labels.l

Standard Note Library

std_note.l

Piping Assembly Library

assembly.l

Piping Spec Table Library

pjs_tbl.l

Short Material Description Library

short_bom.l

Long Material Description Library

long_bom.l

Specialty Description Library

spclty_bom.l

Physical Data Library

_pcdim.l

The text to be used for the is determined in the following manner. Practice

Prefix

U.S. Practice

us

European - DIN

din

European - British Standard

bs

European - Practice A

eua

European - Practice B

eub

International - JIS

jis

International - Australian

aus

International - Practice A

ina

International - Practice B

inb

Company Practice

cmp

Copy All Standard Libraries This option copies the delivered Reference Database libraries from the applicable product directories to the disk locations specified in the Reference Database Management data of the Project Control database. This option provides a new user with a simple method to create a Reference Database using RDB products delivered by Intergraph. This is not intended for use in a production environment. The following Reference Database libraries are copied from the PD Shell product.

Plant Design System (PDS) Piping Eden Interface

77

Creating a New Piping Component Graphic Commodity Library

Standard Note Library

Label Description Library Piping Assembly Library The following Reference Database libraries are copied from the applicable Reference Database product (such as rdusrdb or rddinrdb). Physical Data Library

Long Material Description Library

Piping Spec Table Library

Specialty Description Library

Short Material Description Library The system also copies the applicable Table Revision Management Libraries for the Piping Spec Table Library and Physical Data Libraries. The text to be used for the standard is determined in the following manner. Practice

Prefix

U.S. Practice

us

European - DIN

din

European - British Standard

bs

International - JIS

jis

International - Australian aus The list of available products is determined from the list of exported variables as specified in the pds.cmd shell script. Therefore, this command presently searches for the following exported variables: Product

Practice

RD_USRDB

U.S. Practice

RD_DINRDB

DIN

RD_BSRDB

British Standards

RD_JISRDB

JIS

RD_AUSRDB Australian The file specification recorded in the Project Control Database, and not that of the library in the delivered product, will be used for the destination library. If the RDB product resides on a remote server (or workstation), you must manually mount the directory that includes the RDB product and change the exported variable in the pds.cmd shell script accordingly. The system will display an error message for any of the following conditions.  Any of the active Reference Database libraries for the project are in use (locked). None of the libraries are copied.  The network address for any of the active Reference Database libraries for the project is undefined. None of the libraries are copied.  The network address and path name for any of the active Reference Database libraries for the project cannot be mounted. None of the subsequent libraries are copied.

78

Plant Design System (PDS) Piping Eden Interface

Creating a New Piping Component

Default Project Control Data This button allows you to define the default location for files commonly used by the project (such as neutral files, report files, and library files). You can also set or change these file locations during the operation of the applicable managers.

Operating Sequence 1. Select the field to be defined, and key in the location of the source files and the associated node name. Piping Eden Path / Node The default location for the Eden source files. Eden Table Path / Node

The default location of the Dimension Table and Spec Table source files.

Piping Spec Path / Node

The default location for the neutral files to be used to load the Specification/Material Reference Database.

Assembly Path / Node

The default location for the Piping Assembly Language source files.

Standard Note Library

The default location for the Standard Note (code list) source files.

Equipment Eden Path / Node

The default location for the Equipment Eden source files.

Plant Design System (PDS) Piping Eden Interface

79

Creating a New Piping Component TDF Table Path / Node

The default location for the Equipment tutorial definition files.

Model Builder Path / Node

The default location for the model builder language source files.

2. Select the Confirm () button to accept any changes to the Project Control Data.

Extracting Sample Modules When defining a new component, the first step is to have a sketch of the graphic symbol that will be used to represent that component. Since the piping design software has various items, from basic shapes to complex components, available for placement, the Eden modules for existing components can be extracted and used as models to define new piping components. In order to extract the Eden modules for an existing piping component, the item's model code must be known. There are two ways of determining the model code for a component:

Method I 1. Find the component that would require the least number of modifications to make it appear as the graphics that will represent the new item. 2. Retrieve the model code from the first line on the bottom of the title block. If more than one "MC" are listed, the first one is all that is needed.

Method II 1. Enter the piping design environment. 2. Select the Place component command. 3. Place a component or instrument or specialty item that closely resembles the component to be created. 4. Select the Diagnostics command. 5. Select the Review Component Placement option from the form. The model code is the first item displayed in the message box. The items that appear indented in the message box are the physical data definitions and parametric shape definitions used for placing the component. Once the model code is known, you can extract the symbol processor for the existing item. The name of the symbol processor for a component is always the same as the model code. To obtain all the data about a component, the physical data and parametric shape definitions called from the symbol processor also need to be extracted. These modules may require slight to several changes as well as the symbol processor to create a new component these changes depend on how closely the existing item resembles the new one. To extract the Eden modules for the symbol processor, physical data definition, and parametric shape definition, follow these steps: 1. Select the Reference Data Manager option. 2. Select the Graphic Data Library Manager option. 3. Select the Graphic Data Management option. 4. Toggle Full List to Sub-string. 5. Enter the name of the symbol processor, and press Enter. 6. Select the Extract option. 7. Identify the symbol processor from the form.

80

Plant Design System (PDS) Piping Eden Interface

Creating a New Piping Component 8. Accept the form. 9. Repeat Steps 5-8 for the physical data and parametric shape definitions. 10. Sub symbol processors (valve operators) can be extracted the same way as above. 11. Extracted modules are placed in the symbols directory defined by the user. If the physical data definition for the new component requires dimensions or weight tables that do not already exist, there are two ways of defining tables:

Method I 1. Find the table format that fits the input/output requirements for the new component. 2. Use a screen editor to create the new table(s) following the format requirements found. 3. Place the new table in the tbls (or equivalent) directory previously defined during setup.

Method II 1. 2. 3. 4. 5. 6. 7. 8. 9.

10.

Select the Reference Data Manager option. Select the Graphic Data Library Manager option. Select the Physical Data Management option. Identify the table library being used (U.S. practice, European - Din, and so forth) and accept the form. Toggle Full List to Sub-string. Enter the name of a table used by the physical data definition of the existing component referred to in the steps above, and press Enter. Select the Extract option. Identify the table from the form. Accept the form. The extracted table is placed in the tbls (or equivalent) directory previously defined during setup. Use a screen editor to modify the extracted table as necessary to contain the type of input/output required by the new component.

Editing Modules After the Eden modules for an existing component have been extracted, they can be used as models or modified as needed to make them generate a new component. It is recommended that the symbol processor be created first and the additional modules be created/edited as needed in the same sequence, in which they are called from their parent modules. If the new component will require the creation or editing of forms, turn to the end of this chapter for information about using DBAccess.

Plant Design System (PDS) Piping Eden Interface

81

Creating a New Piping Component

Compiling New Modules To compile newly created Eden modules, they should be loaded to the existing graphic commodity library. New modules are compiled as they are loaded. If everything is correct in the code and compilation is completed, the new modules are incorporated into the graphic commodity library.

To load and compile new Eden modules, follow these steps: 1. 2. 3. 4. 5.

Select the Reference Data Manager option. Select the Graphic Data Library Manager option. Select the Graphic Data Management option. Select either of the Create options. With the toggle set to Single, enter the name of the file containing the new Eden module. If several modules have to be loaded at one time, write their file names to an ASCII file, and enter the name of that file with the toggle set to List. 6. Accept the form. 7. If any errors are found during compilation, take note of what the errors are, edit the incorrect module, and try reloading it. 8. Use the List option to verify that the new module(s) is/are part of the graphic commodity library.

To load and compile new tables, follow these steps: 1. 2. 3. 4. 5.

Select the Reference Data Manager option. Select the Graphic Data Library Manager option. Select the Physical Data Management option. Select either of the Create options. With the toggle set to Single, enter the name of the file containing the new table. If several tables have to be loaded at one time, write their file names to an ASCII file, and enter the name of that file with the toggle set to List. 6. Accept the form. 7. If any errors are found during compilation, take note of what the errors are, edit the incorrect table, and try reloading it. 8. Use the List option to verify that the new table(s) was/were successfully loaded.

Revising Modules After the Eden modules of a new component have been defined, the component should be placed in the piping design environment to verify that it places correctly. Should the component not place correctly, follow these steps to revise the incorrect Eden module: 1. Select the Reference Data Manager option. 2. Select the Graphic Data Library Manager option. 3. Select the Graphic Data Management option. 4. Toggle Full List to Sub-string. 5. Enter the name of the Eden module to be revised. 6. Select the Revise option.

82

Plant Design System (PDS) Piping Eden Interface

Creating a New Piping Component 7. 8. 9. 10.

Identify the Eden module to be revised from the form. Accept the form. Edit the file as needed and exit the editor. The system recompiles the file automatically. Place the component in the design environment to verify fixes.

To revise an incorrect table, follow these steps: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10.

Select the Reference Data Manager option. Select the Graphic Data Library Manager option. Select the Physical Data Management option. Toggle Full List to Sub-string. Enter the name of the table to be revised. Select the Revise option. Identify the table to be revised from the form. Accept the form. Edit the file as needed, and exit the editor. Place the component using the revised table in the design environment to verify fixes.

Basic Use of Forms DBACCESS is used to create the forms needed to interact with the operator. When a new piping item is defined through Eden, some form customization may be required to make the new item accessible to the users. The fastest way to generate a new form or add a new option within an existing form is to copy and edit a standard delivered form. The following general procedure can serve as a guideline when creating a form that is to be linked to a new component: 1. Create a directory where forms can be worked on. This should be done on a workstation that has PDS loaded or that at least has access to the server where PDS products are loaded. 2. Copy into the new forms directory a form used to place an existing component. copy c:\win32app\ingr\pdshell\forms\PA001 forms\. 3. From the forms directory, access DBACCESS. 4. Select the Define Form option. 5. Identify the form to be modified from the list, and accept. 6. Use the Single Edit command to modify those gadgets on the form that only require minor changes such as gadget numbers or text editing. 7. Use the Single Copy command followed by the Single Edit command to copy existing options that should be left intact and edit the new options to perform the desired task. This is useful when reproducing the font or line style of a gadget or when the new gadget will perform a task similar to that of the parent gadget. 8. Use the Characteristics Form when gadget number and other gadget attributes need to be updated. 9. Use Single Delete to remove gadgets from the original form that won't be needed on the new one. 10. Use the Place Gadget option to place fields, buttons, toggles, text, lines, and so forth. 11. Use the Set Form Parameters option to select gadget colors, styles, fonts, and so forth.

Plant Design System (PDS) Piping Eden Interface

83

Creating a New Piping Component 12. Use the Associate Gadgets option to create and manipulate gadget sequences (where the cursor should appear following an entry in a key-in gadget). 13. If you are familiar with the procedures used in piping and equipment modeling for identifying, accepting, and rejecting a selection using the mouse, you will find it easy to follow the prompts provided for each of the FORMS commands 14. When exiting and saving a form, make sure that the exit form has the following selections turned on: No Program Skeleton, Erase Form Yes, Write Form Yes. 15. To place a new or customized form where the piping design software will be able to access it, copy the new form to the pdshell\forms directory. copy PA001 c:\win32app\ingr\pdshell\forms\PA001 16. Refer to the DBACCESS documentation for detailed information on using this product. There is no symbol editor for the Windows environment. However, bitmaps (BMP files) can be used to create symbols.

Piping Specialty Components Specialty Items with Complete Data Input You can customize the I/Forms for instrument and piping specialty components for 'complete data input'. You must adhere to the following conventions. If not documented, any I/Form you customize should remain consistent with those delivered by Intergraph. Intergraph has chosen to name the I/Forms for instruments with 'complete data input' using the convention INA, where are three unique alphanumeric characters. Use the convention INU to avoid confusion with any Intergraph I/Forms. Similarly, the I/Forms for piping specialties with 'complete data input' have been named using the convention PSA. Use the convention PSU to avoid confusion with any Intergraph I/Forms. The I/Forms delivered by Intergraph may be used as examples for customization. buttons (automatic):

84

'operator menu' selection

key = 4090

'placement options' selection

key = 3001

B=A

key = 3012

C=A

key = 3013

D=A

key = 3014

E=A

key = 3015

C=B

key = 3016

B = 0.5 * A

key = 3021

C = 0.5 * A

key = 3022

D = 0.5 * A

key = 3023

E = 0.5 * A 'help' selection:

key = 3024

key:

456

gadget number:

995

Plant Design System (PDS) Piping Eden Interface

Creating a New Piping Component button: 'form size' selection:

automatic

key:

403

gadget number:

997

button: 'exit' selection:

automatic

key:

4001

gadget number:

998

button: 'accept' selection:

manual

key:

4002

gadget number:

999

button: 'connect to piping' selection:

manual

key:

3200

gadget number:

310

button: 'intersection with steel' selection:

manual

key:

4089

gadget number:

89

button: 'piping on segment' selection:

manual

key:

4091

gadget number:

51

button: 'point on pipe' selection:

manual

key:

4092

gadget number:

52

button: manual 'move from active point' selection: key:

4093

gadget number:

53

button: manual 'move from reference point' selection: key:

4094

Plant Design System (PDS) Piping Eden Interface

85

Creating a New Piping Component gadget number:

54

button: manual 'move to coordinate axis' selection: key:

4095

gadget number:

55

button: message area 'a' for messages:

manual

gadget number:

251

characters:

40

lines deep:

3

edit mode:

review only

font size: 12 message area 'b' for active segment data display:

86

gadget number:

254

characters:

40

lines deep:

3

edit mode:

review only

font size: material description display:

12

gadget number:

150

characters:

80

lines deep:

3

edit mode:

review only

font size: input fields:

12

Dimension_1

gadget = 101

Dimension_2

gadget = 102

Dimension_3

gadget = 103

Dimension_4

gadget = 104

Dimension_5

gadget = 105

Dimension_6

gadget = 106

Dimension_7

gadget = 107

Dimension_8

gadget = 108

Dimension_9

gadget = 109

Dimension_10

gadget = 110

Plant Design System (PDS) Piping Eden Interface

Creating a New Piping Component Dimension_11

gadget = 111

Dimension_12

gadget = 112

Dimension_13

gadget = 113

Dimension_14

gadget = 114

Dimension_15

gadget = 115

Dimension_16

gadget = 116

Dimension_17

gadget = 117

Dimension_18

gadget = 118

Dimension_19

gadget = 119

Dimension_20

gadget = 120

tag number

gadget = 130

dry weight

gadget = 201

wet weight

gadget = 202

surface area gadget = 203 All input fields should be sequenced and must have the following characteristics. The settings for 'editing options' in the Form Builder should be as follows. change mode 'not required' 'echo input' 'replace text mode' 'notify by line' The characteristics form in the Form Builder should have the following settings: 'notify upon completion ---> off (NOT the default) 'notify upon initial' ---> off toggles: Toggle_1

Toggle_2

Toggle_3

Toggle_4

Toggle_5

4051

4052

4053

4054

4055

I/Form gadget 981

982

983

984

985

'off' gadgets

701-710

721-730

741-750

761-770

781-790

'on' gadgets

711-720

731-740

751-760

771-780

791-800

I/Form key

Specialty Items With Partial Data Input You can customize the I/Forms for instrument and piping specialty components for 'partial data input'. You must adhere to the following conventions to customize these I/Forms. If not documented, any I/Form you customize should remain consistent with those delivered by Intergraph. Intergraph has chosen to name the I/Forms for instruments with 'partial data input' using the convention INB, where are three unique alphanumeric characters. Use the convention INU to avoid confusion with any Intergraph I/Form. Similarly, the I/Forms for

Plant Design System (PDS) Piping Eden Interface

87

Creating a New Piping Component piping specialties with 'partial data input' have been named using the convention PSB. Use the convention PSU to avoid confusion with any Intergraph I/Forms. These I/Forms delivered by Intergraph can be used as examples for customization. buttons (automatic):

88

'operator menu' selection

key = 4090

'placement options' selection

key = 3001

B=A

key = 3012

C=A

key = 3013

D=A

key = 3014

E=A

key = 3015

C=B

key = 3016

B = 0.5 * A

key = 3021

C = 0.5 * A

key = 3022

D = 0.5 * A

key = 3023

E = 0.5 * A 'help' selection:

key = 3024

key:

456

gadget number:

995

button: 'form size' selection:

automatic

key:

403

gadget number:

997

button: 'exit' selection:

automatic

key:

4001

gadget number:

998

button: 'accept' selection:

manual

key:

4002

gadget number:

999

button: 'connect to piping' selection:

manual

key:

3200

gadget number:

310

button: 'intersection with steel' selection:

manual

Plant Design System (PDS) Piping Eden Interface

Creating a New Piping Component key:

4089

gadget number:

89

button: 'piping on segment' selection:

manual

key:

4091

gadget number:

51

button: 'point on pipe' selection:

manual

key:

4092

gadget number:

52

button: manual 'move from active point' selection: key:

4093

gadget number:

53

button: manual 'move from reference point' selection: key:

4094

gadget number:

54

button: manual 'move to coordinate axis' selection: key:

4095

gadget number:

55

button: message area 'a' for messages:

manual

gadget number:

251

characters:

40

lines deep:

3

edit mode:

review only

font size: 12 message area 'b' for active segment data display: gadget number:

254

characters:

40

lines deep:

3

edit mode:

review only

font size:

12

Plant Design System (PDS) Piping Eden Interface

89

Creating a New Piping Component material description display:

90

gadget number:

150

characters:

80

lines deep:

3

edit mode:

review only

font size: 'review only' fields:

12

first size

gadget = 171

key = 3171

second size 'select/review' fields:

gadget = 176

key = 3176

end preparation (first size)

gadget = 172

key = 3172

end preparation (second size) input fields:

gadget = 177

key = 3177

Dimension_1

gadget = 101

Dimension_2

gadget = 102

Dimension_3

gadget = 103

Dimension_4

gadget = 104

Dimension_5

gadget = 105

Dimension_6

gadget = 106

Dimension_7

gadget = 107

Dimension_8

gadget = 108

Dimension_9

gadget = 109

Dimension_10

gadget = 110

Dimension_11

gadget = 111

Dimension_12

gadget = 112

Dimension_13

gadget = 113

Dimension_14

gadget = 114

Dimension_15

gadget = 115

Dimension_16

gadget = 116

Dimension_17

gadget = 117

Dimension_18

gadget = 118

Dimension_19

gadget = 119

Dimension_20

gadget = 120

Plant Design System (PDS) Piping Eden Interface

Creating a New Piping Component tag number

gadget = 130

dry weight

gadget = 201

wet weight

gadget = 202

surface area

gadget = 203

pressure rating (first size)

gadget = 173

key = 3173

pressure rating (second size)

gadget = 178

key = 3178

schedule/thickness (first size)

gadget = 174

key = 3174

schedule/thickness gadget = 179 key = 3179 (second size) All input fields should be sequenced and must have the following characteristics. The settings for 'editing options' in the Form Builder should be as follows. change mode 'not required' 'echo input' 'replace text mode' 'notify by line' The characteristics form in the Form Builder should have the following settings: 'notify upon completion ---> off (NOT the default) 'notify upon initial' ---> off toggles: Toggle_1

Toggle_2

Toggle_3

Toggle_4

Toggle_5

I/Form key

4051

4052

4053

4054

4055

I/Form gadget

981

982

983

984

985

'off' gadgets

701-710

721-730

741-750

761-770

781-790

'on' gadgets

711-720

731-740

751-760

771-780

791-800

Valve Operators You can customize the I/Forms for valve operators. You must adhere to the following conventions when customizing these I/Forms. If not documented, any I/Form you customize should remain consistent with those delivered by Intergraph. Intergraph has chosen to name the I/Forms for valve operators using the convention VOP, where are three unique alphanumeric characters. Use the convention VOU to avoid confusion with any Intergraph I/Forms. I/Forms delivered by Intergraph may be used as examples for customization. buttons (automatic): 'operator menu' selection

key = 4090

'placement options' selection

key = 3001

Plant Design System (PDS) Piping Eden Interface

91

Creating a New Piping Component 'help' selection: key:

456

gadget number:

995

button: 'form size' selection:

automatic

key:

403

gadget number:

997

button: 'exit' selection:

automatic

key:

4001

gadget number:

998

button: 'accept' selection:

manual

key:

4002

gadget number:

999

button: 'connect to piping' selection:

manual

key:

3200

gadget number:

310

button: 'intersection with steel' selection:

manual

key:

4089

gadget number:

89

button: 'piping on segment' selection:

manual

key:

4091

gadget number:

51

button: 'point on pipe' selection:

manual

key:

4092

gadget number:

52

button: manual 'move from active point' selection:

92

key:

4093

gadget number:

53

Plant Design System (PDS) Piping Eden Interface

Creating a New Piping Component button: manual 'move from reference point' selection: key:

4094

gadget number:

54

button: manual 'move to coordinate axis' selection: key:

4095

gadget number:

55

button: message area 'a' for messages:

manual

gadget number:

251

characters:

40

lines deep:

3

edit mode:

review only

font size: 12 message area 'b' for active segment data display: gadget number:

254

characters:

40

lines deep:

3

edit mode:

review only

font size: input fields:

12

Dimension_1

gadget = 101

Dimension_2

gadget = 102

Dimension_3

gadget = 103

Dimension_4

gadget = 104

Dimension_5

gadget = 105

Dimension_6

gadget = 106

Dimension_7

gadget = 107

Dimension_8

gadget = 108

Dimension_9

gadget = 109

Dimension_10

gadget = 110

Dimension_11

gadget = 111

Dimension_12

gadget = 112

Dimension_13

gadget = 113

Plant Design System (PDS) Piping Eden Interface

93

Creating a New Piping Component Dimension_14

gadget = 114

Dimension_15

gadget = 115

Dimension_16

gadget = 116

Dimension_17

gadget = 117

Dimension_18

gadget = 118

Dimension_19

gadget = 119

Dimension_20

gadget = 120

operator weight gadget = 201 All input fields should be sequenced and must have the following characteristics. The settings for 'editing options' in the Form Builder should be as follows. change mode 'not required' 'echo input' 'replace text mode' 'notify by line' The characteristics form in the Form Builder should have the following settings: 'notify upon completion ---> off (NOT the default) 'notify upon initial' ---> off toggles: Toggle_1

Toggle_2

Toggle_3

Toggle_4

Toggle_5

I/Form key

4051

4052

4053

4054

4055

I/Form gadget

981

982

983

984

985

'off' groups

701-710

721-730

741-750

761-770

781-790

'on' groups

711-720

731-740

751-760

771-780

791-800

Pipe Supports You can customize the I/Form, PSP000.fb, for use as the pipe support menu. You must adhere to the following conventions in customizing this I/Form. If not documented, any other gadgets on the I/Form should remain consistent with those delivered by Intergraph. individual physical pipe support selection: key: "$," where - name of the I/Form to be displayed by Place Pipe Support. - model code of the physical pipe support to be placed by Eden. Intergraph has chosen to name the I/Forms for physical pipe supports using the convention PSP, where are three unique alphanumeric characters. gadget number: defined by user any gadget number not reserved by Intergraph individual functional pipe support selection:

94

Plant Design System (PDS) Piping Eden Interface

Creating a New Piping Component key: "#," where - name of the I/Form to be displayed by Place Pipe Support. - model code of the physical pipe support to be placed by Eden. Intergraph has chosen to name the I/Forms for physical pipe supports using the convention PSP, where are three unique alphanumeric characters. gadget number: defined by user any gadget number not reserved by Intergraph ’help’ selection: key:

456

gadget number:

995

button: ’form size’ selection:

automatic

key:

403

gadget number:

997

button: ’exit’ selection:

automatic

key:

4001

gadget number:

998

button: ’accept’ selection:

manual

key:

4002

gadget number:

999

button: 'connect to piping' selection:

automatic

key:

3200

gadget number:

310

button: 'intersection with steel' selection:

manual

key:

4089

gadget number:

89

button: 'piping on segment' selection:

manual

key:

4091

gadget number:

51

button: 'point on pipe' selection:

manual

Plant Design System (PDS) Piping Eden Interface

95

Creating a New Piping Component key:

4092

gadget number:

52

button: manual 'move from active point' selection: key:

4093

gadget number:

53

button: manual 'move from reference point' selection: key:

4094

gadget number:

54

button: manual 'move to coordinate axis' selection: key:

4095

gadget number:

55

button: message area ’a’ for messages:

manual

gadget number:

251

characters:

40

lines deep:

3

edit mode:

review only

text font: 12 message area ’b’ for active segment data display: gadget number:

254

characters:

40

lines deep:

3

edit mode:

review only

text font: 12 You can customize the I/Forms for pipe supports. You must adhere to the following conventions to customize these I/Forms. If not documented, any I/Form you customize should remain consistent with those delivered by Intergraph. Intergraph has chosen to name the I/Forms for pipe supports using the convention PSP, where is three unique alphanumeric characters. Use the convention SPU to avoid confusion with any Intergraph I/Forms. I/Forms delivered by Intergraph may be used as examples for customization. buttons (automatic): ’pipe support data’ selection

96

key = 4092

Plant Design System (PDS) Piping Eden Interface

Creating a New Piping Component ’help’ selection: key:

456

gadget number:

995

button: ’form size’ selection:

automatic

key:

403

gadget number:

997

button: ’exit’ selection:

automatic

key:

4001

gadget number:

998

button: ’accept’ selection:

manual

key:

4002

gadget number:

999

button: 'connect to piping' selection:

manual

key:

3200

gadget number:

310

button: 'intersection with steel' selection:

manual

key:

4089

gadget number:

89

button: 'piping on segment' selection:

manual

key:

4091

gadget number:

51

button: 'point on pipe' selection:

manual

key:

4092

gadget number:

52

button: manual 'move from active point' selection: key:

4093

gadget number:

53

Plant Design System (PDS) Piping Eden Interface

97

Creating a New Piping Component button: manual 'move from reference point' selection: key:

4094

gadget number:

54

button: manual 'move to coordinate axis' selection: key:

4095

gadget number:

55

button: message area ’a’ for messages:

manual

gadget number:

251

characters:

40

lines deep:

3

edit mode:

review only

font size: 12 message area ’b’ for active segment data display:

98

gadget number:

254

characters:

40

lines deep:

3

edit mode:

review only

font size: material description display:

12

gadget number:

150

characters:

80

lines deep:

3

edit mode:

review only

font size: input fields:

12

Dimension_1

gadget = 121

Dimension_2

gadget = 122

Dimension_3

gadget = 123

Dimension_4

gadget = 124

Dimension_5

gadget = 125

Dimension_6

gadget = 126

Dimension_7

gadget = 127

Plant Design System (PDS) Piping Eden Interface

Creating a New Piping Component Dimension_8

gadget = 128

Dimension_9

gadget = 129

Dimension_10

gadget = 130

Dimension_11

gadget = 131

Dimension_12

gadget = 132

Dimension_13

gadget = 133

Dimension_14

gadget = 134

Dimension_15

gadget = 135

Dimension_16

gadget = 136

Dimension_17

gadget = 137

Dimension_18

gadget = 138

Dimension_19

gadget = 139

Dimension_20

gadget = 140

Dimension_1 & iso dwg dimension A

gadget = 141

Dimension_2 & iso dwg dimension B

gadget = 142

Dimension_3 & iso dwg dimension C

gadget = 143

Dimension_4 & iso dwg dimension D

gadget = 144

Dimension_5 & iso dwg dimension E

gadget = 145

isometric drawing dimension A

gadget = 161

isometric drawing dimension B

gadget = 162

isometric drawing dimension C

gadget = 163

isometric drawing dimension D

gadget = 164

isometric drawing dimension E

gadget = 165

pipe support number

gadget = 51

commodity code

gadget = 55

weight

gadget = 68

fabrication orientation

gadget = 84

details for shop

gadget = 82

details for field

gadget = 83

Gadgets 121 through 140 in the previous list are input fields that pass dimensions into Eden only. Gadgets 141 through 145 pass the dimensions into Eden and pdtable_80. Gadgets 161 through 165 pass dimensions only into pdtable_80 in the database.

Plant Design System (PDS) Piping Eden Interface

99

Creating a New Piping Component All input fields should be sequenced and must have the following characteristics. The settings for ’editing options’ in the Form Builder should be as follows. change mode ’not required’ ’echo input’ ’replace text mode’ ’notify by line’ The characteristics form in the Form Builder should have the following settings: 'notify upon completion ---> off (NOT the default) 'notify upon initial' ---> off

100

Plant Design System (PDS) Piping Eden Interface

APPENDIX A

Appendix: EDEN Error Messages This section lists the EDEN error messages and explanations of the messages.

*** Connect Points Not Defined In Sequence - CPn is missing This error occurs when a connect point is skipped in the definition. For example, connect point 3 is defined without first defining connect point 2.

*** A total of x errors detected - object code NOT generated This is a general purpose message that simply means one or more errors were encountered during generation of the object code. The error will also be covered by one of the more specific error messages.

*** Assignment to read only variable not permitted This error occurs when the EDEN module has an assignment statement trying to assign a value to a read-only variable. Read-only variables include: nom_pipe_d, gen_type, term_type, table_suffix, std_type, min_cyl_dia, dim_tolerance, and min_dimension.

*** Incorrect subroutine name in call statement x This error occurs when a subroutine name has been mistyped and does not match any of the valid subroutine names. The x refers to the sequential number of the call statement within the EDEN module.

*** Fewer than required number of arguments specified in call statement x This error occurs when an argument has been left out of a call statement. The x refers to the sequential number of the call statement in error within the EDEN module.

*** More than required number of arguments specified in call statement x This error occurs when an extra argument has been found for a particular call statement. The x refers to the sequential number of the call statement in error within the EDEN module.

*** Argument x is incorrect in call statement y This error occurs when a call statement is expecting a particular argument and receives and incorrect argument. An example would be the DEFINE_ACTIVE_ORIENTATION call statement. It expects one of the following variables to be used for the arguments: CP_primary_n, CP_secondary_n, CP_normal_n. If any other variable is used (i.e. a user-defined keyword), then this error will occur. The x refers to the incorrect argument in call statement y.

*** Incorrect data type for argument x in call statement y This error occurs when a call statement is expecting a particular data-type in the argument variable. An example would be the CONVERT_NPD_TO_SUBUNITS call statement. It requires the second argument to be a Real*8 data-type. If an ascii type variable was used in this statement, an error would occur. The x refers to the incorrect argument in call statement y.

Plant Design System (PDS) Piping Eden Interface

101

Appendix: EDEN Error Messages *** Incorrect argument specified in call statement x This error occurs when there is an incorrect argument in a call statement. It is similar to the two previous errors.

*** Symbol ID (name) exceeds 28 characters - truncated to (name2) This error occurs when the symbol id specified in the EDEN module exceeds 28 characters - the maximum allowed. The symbol name is automatically truncated to 28 characters.

*** INTERNAL ERROR in symbol name provided by parser This error occurs when a blank symbol name is specified in the EDEN module.

*** INTERNAL ERROR during object code backpatching Due to an internal software error, the data needed to complete the object code generation for a conditional statement in the EDEN code cannot be accessed. You should contact Intergraph and send the EDEN module if this error is encountered.

*** INTERNAL ERROR - Object code being generated is too big to catalogue This error occurs when the total number of bytes of object code has exceeded 9560.

*** INTERNAL ERROR - Number of branch instructions generated exceeds limit The number of nested if-then-else clauses is limited to 5. This error indicates that this nesting limit has been exceeded.

*** INTERNAL ERROR - Can not find information specified by parser Due to an internal software error, the data-type for the variable cannot be determined.

Error opening specified symbol file The symbol file that was specified is read-only or cannot be opened for some other reason. You should check permissions for the file and re-try.

Error obtaining graphic commodity library The graphic commodity library for the project cannot be opened or located. You should check which library is specified using the Reference Database Management Data form to review the current setting for the graphic commodity library.

Internal Error building Semantic Symbol Table This error indicates an internal problem in PDS, and is not related to the EDEN module being processed. If this error occurs, contact Intergraph.

Return Message: Error Writing Text to Text Library An error occurred while trying to write the text of the EDEN module into the text library. Either the library could not be opened for some reason, or there was an internal problem with the library.

Return Message: Error Generating Object Code One of the error messages listed previously should be added at the end of this message when an error occurs during the object code generation part of compiling.

102

Plant Design System (PDS) Piping Eden Interface

Appendix: EDEN Error Messages Illegal Number This error occurs when a number in the EDEN module has character data in it.

String Must be 50 Characters or Less This error occurs when a string variable in the EDEN module exceeds the 50 character maximum length.

Invalid Operation - x This error occurs when the EDEN module has an illegal use of a relational operator (.gt., .le., etc.).

UN-CLASSIFIED symbol (symbol) This error occurs when the compiler encounters a phrase in the EDEN module that cannot be interpreted as a valid number, keyword, phrase, or variable.

SYNTAX ERROR : ( line ) This error occurs when incorrect syntax is used in the EDEN module. For example, this error occurs when the end statement is left off an if-then-else clause.

Build Semantic B-TREE Error This error indicates an internal problem in PDS. If this error occurs, contact Intergraph.

*** Target is not a Vector and/or Array This error occurs when the EDEN module tries to subscript a variable that is not an array type variable.

*** Variable is not declared as ARRAY This error occurs when the EDEN module tries to subscript a variable that is not an array type variable.

*** PRODUCTION Has Not Implemented Yet This error occurs when the EDEN module contains code that is not valid.

Plant Design System (PDS) Piping Eden Interface

103

Appendix: EDEN Error Messages

104

Plant Design System (PDS) Piping Eden Interface

Index A Appendix EDEN Error Messages • 101 Arithmetic Operators • 41 Assign Connect Point • 53 Assign Generic Tap • 54 Assign Tap • 54

B Basic Use of Forms • 83 Beginning Statements • 31 Bends and Branches • 28 Bolts, Gaskets, and Flanges • 28

C Call Statement • 43 Comments • 41 Common Keywords • 38 Compiling New Modules • 82 Component Placement Example • 13 Compute Perpendicular Vector • 55 Connect Point Data • 26 Connect Point Geometry • 67 Convert NPD to Subunits • 46 Creating a New Piping Component • 73

Draw Projected Triangle • 51 Draw Semi-Ellipsoid • 51 Draw Sphere • 52 Draw Torus • 53 Draw Torus with Capped Ends • 61

E Eden Language Structure • 31 Eden Modules • 13 Editing Modules • 81 Ending Statements • 32 Example of Physical Data Look-Up • 11 Expressions • 43 Extracting Sample Modules • 80

F Forms Interface • 26 Functions • 45

G Get Physical Data • 62 Global Variables Common to Piping, Equipment, and Pipe Support Modeling • 34 Graphic Commodity Data • 8 Graphic Commodity Library • 8

D

I

Data Retrieval from the Physical Data Library • 11 Default Project Control Data • 79 Define Active Orientation • 47 Define Connect Point Geometry • 55 Display Tutorial • 56 Do While Statement • 43 Draw Cone • 48 Draw Cone With Capped Ends • 57 Draw Cylinder • 49 Draw Cylinder With Capped Ends • 57 Draw Eccentric Cone • 49 Draw Eccentric Cone With Capped Ends • 58 Draw Hexagon • 59 Draw Mitered Torus • 59 Draw Octagon • 60 Draw Parametric Shape • 61 Draw Projected Rectangle • 50

If - then - else Statement • 44 Indexed Do Statement • 44

Plant Design System (PDS) Piping Eden Interface

K Keywords (Piping Specific) • 38

L Local Variables • 32 Logical Operators • 42

M Move Along Axis • 63 Move By Distance • 63 Move To Connect Point • 64

105

Index

N Notes for Graphic Commodity Data • 26

O Operators • 41

P Parametric Shape Definitions • 23 Physical Data Definitions • 17 Physical Data Tables • 10 Pipe, Tubing, and Hose • 29 Piping Eden Global Variables • 35 Piping Specialty Components • 84 Place COG Location • 64 Place Connect Point • 65 Preface PDS • 5 Primitives • 46 Prompt to Orient Operator • 65

R Read Table • 65 Reference Database Management Data • 75 Relational Operators • 42 Replacement Statements • 43 Revising Modules • 82 Rotate Orientation • 66

S Sub-Symbol Processor • 16 Symbol Processors • 15

T The Eden Basics • 7

V Variables • 32

W What's New in Piping Eden Interface • 6

106

Plant Design System (PDS) Piping Eden Interface

View more...

Comments

Copyright ©2017 KUPDF Inc.
SUPPORT KUPDF