PDS Ortho User's Guide.pdf
Short Description
PDS Ortho...
Description
Plant Design System (PDS) Ortho Draw User's Guide
Version 2009 (V10)
February 2009
DPDS3-PE-200052A
Copyright Copyright © 2008-2009 Intergraph Corporation. All Rights Reserved. Including software, file formats, and audiovisual displays; may be used pursuant to applicable software license agreement; contains confidential and proprietary information of Intergraph and/or third parties which is protected by copyright law, trade secret law, and international treaty, and may not be provided or otherwise made available without proper authorization from Intergraph Corporation.
U.S. Government Restricted Rights Legend Use, duplication, or disclosure by the government is subject to restrictions as set forth below. For civilian agencies: This was developed at private expense and is "restricted computer software" submitted with restricted rights in accordance with subparagraphs (a) through (d) of the Commercial Computer Software - Restricted Rights clause at 52.227-19 of the Federal Acquisition Regulations ("FAR") and its successors, and is unpublished and all rights are reserved under the copyright laws of the United States. For units of the Department of Defense ("DoD"): This is "commercial computer software" as defined at DFARS 252.227-7014 and the rights of the Government are as specified at DFARS 227.7202-3. Unpublished - rights reserved under the copyright laws of the United States. Intergraph Corporation P.O. Box 240000 Huntsville, AL 35813 Street address: 170 Graphics Drive, Madison, AL 35758
Terms of Use Use of this software product is subject to the End User License Agreement and Limited Product Warranty ("EULA") delivered with this software product unless the licensee has a valid signed license for this software product with Intergraph Corporation. If the licensee has a valid signed license for this software product with Intergraph Corporation, the valid signed license shall take precedence and govern the use of this software product. Subject to the terms contained within the applicable license agreement, Intergraph Corporation gives licensee permission to print a reasonable number of copies of the documentation as defined in the applicable license agreement and delivered with the software product for licensee's internal, non-commercial use. The documentation may not be printed for resale or redistribution.
Warranties and Liabilities All warranties given by Intergraph Corporation about equipment or software are set forth in the EULA provided with the software or applicable license for the software product signed by Intergraph Corporation, and nothing stated in, or implied by, this document or its contents shall be considered or deemed a modification or amendment of such warranties. Intergraph believes the information in this publication is accurate as of its publication date. The information and the software discussed in this document are subject to change without notice and are subject to applicable technical product descriptions. Intergraph Corporation is not responsible for any error that may appear in this document. The software discussed in this document is furnished under a license and may be used or copied only in accordance with the terms of this license. No responsibility is assumed by Intergraph for the use or reliability of software on equipment that is not supplied by Intergraph or its affiliated companies. THE USER OF THE SOFTWARE IS EXPECTED TO MAKE THE FINAL EVALUATION AS TO THE USEFULNESS OF THE SOFTWARE IN HIS OWN ENVIRONMENT. Intergraph is not responsible for the accuracy of delivered data including, but not limited to, catalog, reference and symbol data. Users should verify for themselves that the data is accurate and suitable for their project work.
Trademarks Intergraph, the Intergraph logo, PDS, SmartPlant, FrameWorks, I-Convert, I-Export, I-Sketch, SmartMarine, IntelliShip, INtools, ISOGEN, MARIAN, SmartSketch, SPOOLGEN, SupportManager, and SupportModeler are trademarks or registered trademarks of Intergraph Corporation or its subsidiaries in the United States and other countries. Microsoft and Windows are registered trademarks of Microsoft Corporation. Oracle, JD Edwards, PeopleSoft, and Retek are registered trademarks of Oracle Corporation and/or its affiliates. MicroStation is a registered trademark of Bentley Systems Inc, all rights reserved. Other brands and product names are trademarks of their respective owners.
Contents Preface PDS ................................................................................................................................................ iii PDS Ortho Draw Overview ....................................................................................................................... 1 Installation ................................................................................................................................................... 3 PDS Ortho Draw System Requirements ................................................................................................ 3 PDS Ortho Draw Installation ................................................................................................................. 4 PDS Ortho Draw Environment Variables .............................................................................................. 6 PDS Ortho Draw Initial Setup................................................................................................................ 7 Overview ...................................................................................................................................................... 9 PDS Ortho Draw Login Dialog Box .................................................................................................... 11 Main Menu ........................................................................................................................................... 12 Drawing Update Dialog Box ................................................................................................................ 13 Drawing General Information .............................................................................................................. 14 View General Information ................................................................................................................... 17 Match Line Data................................................................................................................................... 18 Generation Setting ................................................................................................................................ 19 Option................................................................................................................................................... 20 Generate Drawing ................................................................................................................................ 21 Drawing View ...................................................................................................................................... 22 Settings ....................................................................................................................................................... 25 Environment ......................................................................................................................................... 26 PDS Model Setting............................................................................................................................... 28 Discipline Setting ................................................................................................................................. 30 Drawing Type Setting .......................................................................................................................... 31 Piping Diameter Table ......................................................................................................................... 32 Option Profile Manager........................................................................................................................ 33 User Account........................................................................................................................................ 34 Generation Setting ................................................................................................................................ 34 Generation Setting - Common ....................................................................................................... 36 Generation Setting - Piping ........................................................................................................... 36 Generation Setting - HVAC........................................................................................................... 38 Generation Setting - Electrical....................................................................................................... 40 Drawing ..................................................................................................................................................... 43 Generation Drawing ............................................................................................................................. 43 View Drawing ...................................................................................................................................... 44 Update Drawing ................................................................................................................................... 44
Plant Design System (PDS) Ortho Draw User's Guide
i
Option ........................................................................................................................................................ 45 Common Option ................................................................................................................................... 45 PCS Monument Tab (Common Options Dialog Box) ................................................................... 47 Unit Tab (Common Options Dialog Box) ..................................................................................... 47 Symbology Tab (Common Options Dialog Box) .......................................................................... 49 Location Tab (Common Options Dialog Box) .............................................................................. 53 Dimension Tab (Common Options Dialog Box) ........................................................................... 54 Symbol Tab (Common Options Dialog Box) ................................................................................ 55 Chart Tab (Common Options Dialog Box) ................................................................................... 57 Misc Tab (Common Options Dialog Box) .................................................................................... 58 Piping Option ....................................................................................................................................... 59 Range Tab (Piping Option Dialog Box) ........................................................................................ 60 Elevation Tab (Piping Option Dialog Box) ................................................................................... 61 Condition Tab (Piping Option Dialog Box) .................................................................................. 62 Label Tab (Piping Option Dialog Box) ......................................................................................... 69 Symbology Tab (Piping Option Dialog Box) ................................................................................ 75 Location Tab (Piping Option Dialog Box) .................................................................................... 81 Dimension Tab (Piping Option Dialog Box) ................................................................................. 82 Symbol Tab (Piping Option Dialog Box) ...................................................................................... 84 Chart Tab (Piping Option Dialog Box) ......................................................................................... 88 Report Tab (Piping Option Dialog Box) ....................................................................................... 91 HVAC Option ...................................................................................................................................... 93 Elevation Tab (HVAC Option Dialog Box) .................................................................................. 93 Condition Tab (HVAC Option Dialog Box) ................................................................................. 95 Label Tab (HVAC Option Dialog Box) ...................................................................................... 100 Symbology Tab (HVAC Option Dialog Box) ............................................................................. 103 Location Tab (HVAC Option Dialog Box) ................................................................................. 107 Dimension Tab (HVAC Option Dialog Box) .............................................................................. 108 Symbol Tab (HVAC Option Dialog Box) ................................................................................... 110 Chart Tab (HVAC Option Dialog Box)....................................................................................... 112 Electrical Option ................................................................................................................................ 113 Structure Grid Data Option ................................................................................................................ 126 Report ...................................................................................................................................................... 127 Report On/Off .................................................................................................................................... 127 Pipe Line ............................................................................................................................................ 129 Piping Support.................................................................................................................................... 130 Piping Instrument Item ....................................................................................................................... 131 Piping Special Item ............................................................................................................................ 132 Equipment .......................................................................................................................................... 133 Equipment Nozzle .............................................................................................................................. 134 Editor ....................................................................................................................................................... 135 Index ........................................................................................................................................................ 139
ii
Plant Design System (PDS) Ortho Draw User's Guide
Preface PDS This document provides command reference information and procedural instructions for the PDS Ortho Draw task.
List of PDS Documentation
DPDS3-PB-200003 - DesignReview Integrator (PD_Review) Reference Guide
DPDS3-PB-200004 - Drawing Manager (PD_Draw) User's Guide
DPDS3-PB-200005 - EE Raceway Modeling Reference Guide
DPDS3-PB-200006 - Interference Checker/Manager (PD_Clash) User's Guide
DPDS3-PB-200010 - PDS 3D Theory User's Guide
DPDS3-PB-200013 - PDS EDEN Interface Reference Guide Volume I : Piping
DPDS3-PB-200015 - PDS Equipment Modeling (PD_EQP) User's Guide
DPDS3-PB-200017 - PDS ISOGEN Reference Guide, Vol. 1
DPDS3-PB-200022 - PDS Piping Component Data Reference Guide
DPDS3-PB-200023 - PDS Project Setup Technical Reference
DPDS3-PB-200025 - PDS Stress Analysis Interface (PD_Stress) User's Guide
DPDS3-PB-200026 - Pipe Supports Modeler Reference Guide
DPDS3-PB-200028 - Piping Design Graphics (PD_Design) Reference Guide
DPDS3-PB-200030 - Project Administrator (PD_Project) Reference Guide
DPDS3-PB-200033 - Project Engineer HVAC (PE-HVAC) Reference Guide
DPDS3-PB-200034 - Reference Data Manager (PD_Data) Reference Guide
DPDS3-PB-200035 - Report Manager (PD_Report) User's Guide
DPDS3-PB-200041 - PDS EDEN Interface Reference Guide Volume 2 : Equipment
DPDS3-PB-200042 - PDS EDEN Interface Reference Guide Volume 3 : Pipe Supports
DPDS3-PE-200016 - PDS Express Project Creation Quick Start Guide
DPDS3-PE-200052 - PDS Ortho Draw User's Guide
DPDS3-PE-200029 - Piping Model Builder (PD_Model) Reference Guide
DPDS3-PE-200031 - Project Engineer HVAC Getting Started Guide
DPDS3-PE-200032 - Project Engineer HVAC Overview
DPDS3-PE-200045 - PDS Label Library Merger Utility
DPDS3-PE-200047 - PDS Reference Data Auditing Tool
DPDS3-PE-200048 - Pipe Supports Explorer Utility
DPDS3-PE-200050 - Batch Services Quick Start Guide
DPDS3-PE-200051 - Batch Services User's Guide
Plant Design System (PDS) Ortho Draw User's Guide
iii
Preface PDS
iv
Plant Design System (PDS) Ortho Draw User's Guide
SECTION 1
PDS Ortho Draw Overview This User's Guide explains in detail on how to create the optimal drawing in the shortest amount of time, the preceding work that must be carried out to create the desired drawing, and on the logic involved in how the PDS Ortho Draw creates the drawing. The beginning of each chapter starts off with the introduction of the content explained in the chapter and the chapter proceeds with a detailed explanation of the topic. The explanation of each process focuses on the business practice perspective, which allows the user to easily get used to PDS Ortho Draw by simply following the process. This also makes it easy to be applied to real projects.
Who This User's Guide is For This User Guide is meant for users who wish to create the drawings out of models that have been modeled with the use of PDS®. This guide is written from the user’s perspective, so with the basic knowledge on certain parts of PDS®’s Design Data and Drawing Manager, an optimal drawing can be made just with the use of this User Guide. If an overall knowledge of PDS® including its Modeling function is acquired, then it could serve to help solving problems presented during drawing creation arising from modeling errors.
Online Documentation All related documents are provided in PDF(Portable Document Format) File. It is possible to browse, search, and print categories not related to the OS type with the use of Acrobat Reader provided by Adobe Systems Incorporated.
Customer Support If you have any question or request, please contact Intergraph support: http://www.intergraph.com/support
See Also Installation (on page 3) Overview (on page 9) Settings (on page 25) Drawing (on page 43) Option (on page 45) Editor (on page 135)
Plant Design System (PDS) Ortho Draw User's Guide
1
PDS Ortho Draw Overview
2
Plant Design System (PDS) Ortho Draw User's Guide
SECTION 2
Installation The section describes how to install PDS Ortho Draw.
In This Section PDS Ortho Draw System Requirements ........................................ 3 PDS Ortho Draw Installation ......................................................... 4 PDS Ortho Draw Environment Variables ...................................... 6 PDS Ortho Draw Initial Setup ....................................................... 7
PDS Ortho Draw System Requirements Operating System
Microsoft Windows 2000 Professional/Server with Service Pack 1 or Higher
Microsoft Windows XP Professional/Server with Service Pack 1 or Higher
Microsoft Windows Vista with Service Pack 1 or Higher
Microsoft Internet Explorer 5.0 or Higher
Software
Bentley MicroStation J (Complete installation)
RIS 05.05 or higher
SmartPlant License Manager Version 2009 (V10) or higher
Hardware
Intel Pentium 4 Processor-based PC
Minimum memory 512 MB
SVGA 17” monitor with 16MB VRAM
Plant Design System (PDS) Ortho Draw User's Guide
3
Installation
PDS Ortho Draw Installation 1. Start PDS Ortho Draw installation by double-clicking PDS Ortho Draw Setup file.
2. 3. 4. 5.
4
Click Next to continue. Enter your name and company name, and then click Next. Click Display to display the license agreement. Click Yes to accept the license agreement. You cannot install PDS Ortho Draw without accepting the license agreement.
Plant Design System (PDS) Ortho Draw User's Guide
Installation 6. Select the installation folder location, and then click Next. The default location is c:\win32app\ingr\PDORTHO\.
7. Click Next. 8. Click Finish to complete the installation of PDS Ortho Draw.
Plant Design System (PDS) Ortho Draw User's Guide
5
Installation
PDS Ortho Draw Environment Variables You need to set a few environment variables before you run PDS Ortho Draw for the first time. 1. Click Start > Control Panel > System and Maintenance > System > Advanced system settings > Environment Variables. 2. Set TEMP and TMP to c:\temp or to another folder path that does not contain spaces in the path. 3. Create a new variable named MS and set it to c:\Bentley\Program\MicroStation\
4. Click OK.
See Also Installation (on page 3)
6
Plant Design System (PDS) Ortho Draw User's Guide
Installation
PDS Ortho Draw Initial Setup You need to do the following to setup PDS Ortho Draw for a new PDS project. 1. Click Start > All Programs > PD_Shell > PD_Ortho > PDOrtho. The PDS Ortho Draw - Login dialog box appears.
2. Click on the Login dialog box to open a database that holds all set values of PDS Ortho Draw. 3. Copy and paste the seed file named PDORTHO.mdb in the same folder. 4. Rename the copied PDORTHO.mdb file to match the name of the PDS project. In this example, you would rename the file to be proj1.mdb. 5. Select the new .mdb file (proj1.mdb in this example), and then click Open. 6. Type admin for the password, and then click Login. The main PDS Ortho Draw window appears. 7. Select Settings > Environment.
Plant Design System (PDS) Ortho Draw User's Guide
7
Installation The Environment Setting dialog box appears. 8. Verify the PDS Version setting matches the version of PDS that you are using. 9. Enter the correct file paths for Design DDL File Path, EQP DLL File Path, and the Pelican Forge MDB File Path. 10. Enter the correct file paths for Original Drawing Path and Drawing Output Path. 11. Click Save, and then click Cancel to exit the Environment Setting dialog box. 12. Select Settings > PDS Model Settings. The PDS Model Setting dialog box appears. 13. Open Windows Explorer and find the mdlsdz.dgn file in the PDS project folder, and then open the .dgn file using MicroStation. 14. Using the Settings > Design File > Working Units command in MicroStation, find the value in the Pos Units Per field. 15. Type in the design file's Pos Units Per value in the PDS Model Settings dialog box Unit Factor field. 16. Click Save, and then click Cancel to exit the PDS Model Setting dialog box. You can also exit MicroStation. 17. Select Options > Common. 18. Select the Units tab. 19. Verify the units match the units of your PDS project. 20. Click Save, and then click Cancel.
Setting the Drawings Type
8
1. 2. 3. 4. 5. 6.
Start PD Shell, select the project, and then click Reference Data Manager. Click Standard Note Library Manager > Extract. Select code list number 2000 (Orthographic Drawing Type). Click Accept. Exit PD Shell. Select Settings > Drawing Type Setting. The Drawing Type Setting dialog box appears.
7. 8. 9. 10.
Click Import. Find and select the .edt file that you exported from PD Shell, and then click Open. Click Save, and then click Cancel. In the main PDS Ortho Draw window, click Update Drawings. The Update Drawings dialog box appears.
11. 12. 13. 14.
In the Update Drawings dialog box, click Update Drawing Type. In the Default Option Profile field, select the profile to use. Click Update Drawing. Click Exit to close the Update Drawings dialog box.
Plant Design System (PDS) Ortho Draw User's Guide
Overview
SECTION 3
Overview This section focuses on the basic concepts of PDS Ortho Draw and the standard processing procedures.
PDS Ortho Draw Concept
Extract View and Drawing Data - Extract detailed information regarding drawing and view needed for creating the drawing from PDS DB(Oracle), and save them on PDS Ortho Draw DB(MDB). White Space Search - Once the selected drawing is created, then design information of each drawing is extracted, then only the information that is related to the current view’s volume is selected with the use of Clip Boundary Logic and marked on the drawing to find the most adequate space. Automatic Annotation & Dimension - Once the coordinates to be marked on the Drawing are decided on, then begin the dimension and annotation process in the following order: Drawing Tag > External Dimension > Internal Dimension > Internal Label > External Label.
Plant Design System (PDS) Ortho Draw User's Guide
9
Overview View Drawing - Once the Drawing is created, go into the View Drawing menu to change the location of the Annotation or to add new dimensions.
Input of PDS Ortho Draw Design Data - It is used to indicate information about the model of PDS Design Database in Drawing. Drawing Data - The user can modify Drawing Title, Drawing Notes, Revision No., and Revision History to use them. View Data - The user can modify Composite Status of View, or Boundary information to use them. Common Option - Set the options used for all types of drawings regardless of the drawing type to create a drawing. Piping Drawing Option - Set options to be used to create piping drawings. HVAC Drawing Option - Set options to be used to create HVAC drawings. Electrical Drawing Option - Set options to be used to create electrical drawings.
See Also PDS Ortho Draw Login Dialog Box (on page 11) Main Menu (on page 12) Drawing Update Dialog Box (on page 13) Drawing General Information (on page 14) View General Information (on page 17) Match Line Data (on page 18) Generation Setting (on page 19) Option (on page 20) Generate Drawing (on page 21) Drawing View (on page 22)
10
Plant Design System (PDS) Ortho Draw User's Guide
Overview
PDS Ortho Draw Login Dialog Box You use PDS Ortho Draw Login dialog box to define the PDS project that you want to connect to and to start PDS Ortho Draw. To open the login dialog box, click Start > All Programs > PD_Shell > PD_Ortho > PD_Ortho.
PDS Project No. - Select a project to create a drawing using PDS Ortho Draw. Project Database - Click on the Login dialog box to open a database that holds all set values of PDS Ortho Draw. A seed file named PDORTHO.mdb is used when producing new projects, therefore PDORTHO.mdb must be copied into a new name (ProjectName).mdb for use. The default location of the seed file is c:\win32app\ingr\PDORTHO\mdb. Username - Enter the username. The default username is Admin. Login Password - Enter the password for username. The initial password for Admin as a default user is set to admin. PD Schema Name - The PDS PD_Schema Name of the selected project is automatically displayed. Plant Design System (PDS) Ortho Draw User's Guide
11
Overview DD Schema Name - The PDS DD_Schema Name of the selected project is automatically displayed. EE Schema Name - The PDS EE_Schema Name of the selected project is automatically displayed. PRJ Schema Name - The PDS PRJ_Schema Name of the selected project is automatically displayed. Login Module - Select the PDS Ortho Draw module to open. Select the Generator module if you want to create or edit drawings. Select the Editor module if you just want to view drawings.
See Also Overview (on page 9)
Main Menu If log-in is successfully processed, the main page appears as shown.
Menu - Contains all the menus provided by PDS Ortho Draw. Toolbar - Contains all the tool buttons provided by PDS Ortho Draw.
12
Plant Design System (PDS) Ortho Draw User's Guide
Overview Drawing Hierarchy - Used for searching drawings. During initial startup, even if the drawing is produced in the PDS, if it has not been updated onto the PDS Ortho Draw’s database, then nothing will be listed. Total Drawings - Indicates the number of drawings registered in PDS Ortho Draw. Update Drawings - Imports the applicable project’s drawing and view data from the PDS Database. Status Bar - Indicates information such as project name and user name. Shortcut to Options - Click to move on to the selection screen for each option. If Drawing or View is selected from the Drawing Hierarchy, then the screen will change to the information page of Drawing or View.
See Also Overview (on page 9)
Drawing Update Dialog Box Click Update Drawings to display the Drawing Update dialog box.
Drawing Type List - Displays the drawing type of the project currently registered on PDS Ortho Draw PDS. Update Drawing Type - Brings the drawing type of the current project from the PDS Database. Default Option Profile - Selects an option profile to be applied to the drawings that will be updated by Drawing Update. Plant Design System (PDS) Ortho Draw User's Guide
13
Overview Remain User Input Data - Decides on whether to preserve the data that has been previously entered by the user during drawing update. (Option Profile, Drawing Title) Clicking Update Drawing Type runs the Batch Service as background to update the drawing type. Select the updated drawing type and the option profile to be used as the standard, then click Update Drawing to update the drawing and view data by running the batch service as background.
See Also Overview (on page 9)
Drawing General Information When you select a drawing in the Drawing Hierarchy, information about that drawing displays as follows:
General Information Drawing Information - It is possible to check and enter the applicable option profile, revision status, and information on the selected drawing.
14
Plant Design System (PDS) Ortho Draw User's Guide
Overview Drawing Title - The user can check and input a drawing title of the selected drawing. Save Drawing Data - Saves information which is set in the General Information, Drawing Note, Revision History tab.
Drawing Note
The user can check and enter the content of the drawing note to be indicated on the drawing.
Plant Design System (PDS) Ortho Draw User's Guide
15
Overview
Revision History
The user can check and input contents of the Revision History Chart that will be displayed on the drawing. To refer to the output of the Revision History Chart, see Drawing (on page 43).
See Also Overview (on page 9)
16
Plant Design System (PDS) Ortho Draw User's Guide
Overview
View General Information Select View of a Drawing to display information about that View.
View Information - Displays information about the selected View and Structure Grid Area, Composition Status, and View Type to be applied. View Volume - Displays information about Volume of the selected View. Save View Data - Saves information which is set in the General Information, Match Line Data tab.
See Also Overview (on page 9)
Plant Design System (PDS) Ortho Draw User's Guide
17
Overview
Match Line Data This tab is used to define prefixes for match line drawing numbers and deck heights. You can also define where match lines drawing numbers are to appear on the drawing.
Prefix for Match Drawing No. - Enter the sequence of characters to be entered in the front section of the Match Drawing No. to be marked on the drawing. Prefix for Deck Height - Input letters to be inserted at the front of the Deck Height to be displayed on the drawing. Match Drawing No. - Enter the matching drawing number to be marked on the drawing in the appropriate colored box (pink, yellow, or blue). Select the check box next the text box to set whether to mark the matching drawing number at that location.
See Also Overview (on page 9)
18
Plant Design System (PDS) Ortho Draw User's Guide
Overview
Generation Setting Select Generation Setting to set categories to be displayed on the drawing.
To set the Generation Setting, select Setting > Piping from the Menu.
from the Toolbar, or select Settings > Generation
To refer to details of Generation Setting, see Generation Setting - Piping (on page 36).
Plant Design System (PDS) Ortho Draw User's Guide
19
Overview
See Also Overview (on page 9)
Option Select box.
in the toolbar or Option > Piping in the menu to display the Piping Option dialog
For more information, see Option (on page 45).
See Also Overview (on page 9)
20
Plant Design System (PDS) Ortho Draw User's Guide
Overview
Generate Drawing To produce a drawing, select the drawing to be produced from the Drawing Hierarchy. At least one drawing must be selected in order to produce a drawing.
In this case, selecting the desired view out of all the views belonging to the Drawing can also produce the drawing.
from the Toolbar, Drawing > After checking the Drawing and View to be produced, select Generate > Piping Drawing from the Menu, or right click the Drawing and select Generate > Piping Drawing. This will produce a drawing according to the selected Option Profile.
See Also Overview (on page 9)
Plant Design System (PDS) Ortho Draw User's Guide
21
Overview
Drawing View There are three ways to see the created drawing: 1. Click in the toolbar after selecting the drawing in the Drawing Hierarchy window. 2. Select the drawing in the Drawing Hierarchy window, and go to Drawing menu > Select View Drawing. 3. Select the drawing in the Drawing Hierarchy window, right click, and select View Drawing from the menu.
22
Plant Design System (PDS) Ortho Draw User's Guide
Overview By processing the View Drawing, the DGN file of the corresponding Drawing will run on the MicroStation and will be opened.
See Also Overview (on page 9)
Plant Design System (PDS) Ortho Draw User's Guide
23
Overview
24
Plant Design System (PDS) Ortho Draw User's Guide
SECTION 4
Settings This section describes the basic setting and the production of each discipline, and the specific categories.
In This Section Environment .................................................................................. 26 PDS Model Setting ........................................................................ 28 Discipline Setting........................................................................... 30 Drawing Type Setting .................................................................... 31 Piping Diameter Table ................................................................... 32 Option Profile Manager ................................................................. 33 User Account ................................................................................. 34 Generation Setting ......................................................................... 34
Plant Design System (PDS) Ortho Draw User's Guide
25
Settings
Environment Selecting Setting > Environment or clicking on the will display the Environment Setting dialog box and it will be classified into PDS Project Information and PDS Ortho Draw Environment Settings.
The PDS Project Information will automatically set the value of the Project, thus the user does not have to manually set the value. The necessary path is set from the PDS Ortho Draw Environment Settings. Each path can be tracked or entered by clicking on the
button, and supports the UNC Path.
Design DDL File Path - Set the path where Design DDL File is located. DDL File includes the Label Definition and the DB table and column information needed for setting the column of each chart. Thus the DDL File used by each Project must be set. EQP DDL File Path - Set the path where Equipment DDL File is located. Pelican Forge MDB File Path - Set the path where Pelican Forge MDB File is located. FrameWorks Plus Path - Set the path where FrameWorks Plus is located.
26
Plant Design System (PDS) Ortho Draw User's Guide
Settings Original Drawing Path - Set the path where Original DGN File is located. When using copied DGN instead of original DGN File for producing drawings, the Original Drawing Path must be set and the checkbox must be checked. If this checkbox is not checked, then the path defined in the PDS Database will be used during drawing production. If the set path does not exist within the DGN File, then the drawing will not be produced.
Generated Drawing Path - Set the path where PDS Ortho Draw result file is saved. If the checkbox is checked, then the DGN File will be copied from the set path of the Original Drawing Path to the Generated Drawing Path for producing the drawing. If the checkbox is not checked, then the drawing will be produced onto the DGN File of the set path of the Original Drawing Path. It is recommended to set so that the drawing is not produced onto the original DGN File. Drawing Report File Path - Set the path where Report Files are saved. Cell Library File Path - Set the path of the Cell Library File used for PDS Ortho Draw. The ‘pdortho.cel’ file under the PDS Ortho Draw installation directory is provided. Thus it can be used or altered for use.
See Also Settings (on page 25)
Plant Design System (PDS) Ortho Draw User's Guide
27
Settings
PDS Model Setting Selecting Setting > PDS Model Setting or clicking allows the setting of categories related to PDS Model, and this is classified into PDS and FrameWorks Plus. PDS - Set a unit factor. Input the resolution of the Project Seed File as a Design Model Unit Factor.
28
Plant Design System (PDS) Ortho Draw User's Guide
Settings FrameWorks+ - Set the symbology of the Grid Line and Column modeled on FrameWorks Plus. The values set here will be noted as the Grid and Column.
See Also Settings (on page 25)
Plant Design System (PDS) Ortho Draw User's Guide
29
Settings
Discipline Setting Selecting Setting > Discipline or clicking on will display the Discipline Setting dialog box and the Discipline Index No. can be set. Discipline is set to the value of the Project DB, and it can be altered between 1~20. The Discipline existent on the DB is saved on PD_SCHEMA PDTABLE_113 of each Project.
See Also Settings (on page 25)
30
Plant Design System (PDS) Ortho Draw User's Guide
Settings
Drawing Type Setting Select Setting > Drawing Type Setting or click , then the Drawing Type Setting dialog box will be displayed. The user can create, delete and import the drawing type in the window. The Drawing Type is a number in drawing hierarchy by drawing update. Using this setting, you can set each drawing type's description. Input directly by right-click or import drawing type code file (ex:code2000.edt) extracted Standard note Library Manager of PD_Shell's Reference Data Manager.
See Also Settings (on page 25)
Plant Design System (PDS) Ortho Draw User's Guide
31
Settings
Piping Diameter Table Select Setting > Piping Diameter Table or click , then the Piping Diameter Table Setting dialog box displays. You can create new and modify the delivered piping diameters in the list. You cannot delete the delivered piping diameter tables. However, you can delete piping diameter tables that you have created.
PDS Ortho Draw provides ANSI and JIS. The value can be manually altered on the Table and saved with the Save button, and it can be saved under another name with the Save as option. Furthermore, selecting on a Table from the Dia Table List and clicking on the Delete Table deletes the produced table, and the Import and Export functions can be used to either save it as an Excel File or to import from an Excel file.
See Also Settings (on page 25)
32
Plant Design System (PDS) Ortho Draw User's Guide
Settings
Option Profile Manager Selecting Setting > Option Profile Manager or clicking activates the Option Profile Manager dialog box, and the option profile comprising all options and setting categories (excluding PDS Model, Discipline, Piping Diameter Setting) can be edited, and can be imported/exported after transforming it into an Excel file. The Option Profile applied on each Drawing can be checked from the Drawing Information shown, and opening the combo box will display a profile list that can be changed. Here, making the changes and saving it with the Saving Drawing Data button can alter the options. To produce the new Profiled applied on each Drawing can be done with the Save As function. It is convenient to create the Option Profile for each drawing size, drawing type, and view type.
See Also Settings (on page 25)
Plant Design System (PDS) Ortho Draw User's Guide
33
Settings
User Account Selecting Setting > User Account or click , to display the User Account dialog box. The user can create, modify and delete the user account in the window. Select account type between ADMIN or ENDUSER by create button. Created user account is shown at user list. ENDUSER is limited some setting. The User can change user name and password by revise button and delete user account by delete button.
See Also Settings (on page 25)
Generation Setting Selecting Setting > Generation Setting allows the user to set the On/Off of each item to be produced for each Piping, HVAC, and Electrical classifications. The Label can be set for each Plan, Section, and Iso, and the Accessory Data and Chart are both applied. The cautionary note is to make sure to check that this Option Profile is identical to the Option Profile of the Drawing to be generated by the user. If the settings do not match, then a completely unexpected result can be generated.
34
Plant Design System (PDS) Ortho Draw User's Guide
Settings When you place structural labels on Piping, HVAC, and Electrical, the sparse structural model is attached to the drawing view or to the model in PDS. Also, the propagated model (PRP file) is attached only for graphics; ortho extracts data for label placement from sparse (.DGN) model.
See Also Generation Setting - Common (on page 36) Generation Setting - Piping (on page 36) Generation Setting - HVAC (on page 38) Generation Setting - Electrical (on page 40)
Plant Design System (PDS) Ortho Draw User's Guide
35
Settings
Generation Setting - Common On the right side of each Discipline Setting of the Generation Setting are the categories that can be commonly applied.
External Label Duplication Check - Set processing of the label which is overlapped with the other displayed out of the view boundary.
None - Do not remove the overlapped label.
One Side - Generate only one label if the labels are overlapped in the same direction.
Whole Side - Generate only one label if the labels are overlapped, regardless of its direction.
Drawing Report - Drawing report’s On/Off setting. Each drawing report file (.csv) will be saved the path set on the Environment Setting dialog box. For more information, see Environment (on page 26). To refer to details about setting an item, see Drawing Report in Piping Option (on page 59)
See Also Generation Setting (on page 34)
Generation Setting - Piping Selecting Setting > Generation Setting > Piping or clicking on allows you to turn On/Off the categories marked on the Piping Drawing classified into Label, Accessory Data, or Chart. The categories that are not supported or that cannot be marked cannot be selected. Label - Select a label to be displayed in below categories by Plan View, Section View, and ISO View. When you place structural labels on Piping, HVAC, and Electrical, the sparse structural model is attached to the drawing view or to the model in PDS. Also, the propagated model (PRP file) is attached only for graphics; ortho extracts data for label placement from sparse (.DGN) model. To refer to details about setting an item, see Label Definition in Piping Option (on page 59).
36
Pipe Line Label
Clipped Coordinates
Elevation Label Plant Design System (PDS) Ortho Draw User's Guide
Settings
Working Point Elevation
Pipe Spool Label
Ref. Equipment Label
Main Equipment Label
Equipment Nozzle No.
Structure Grid
Structure Grid
Structure Member Section
Structure Platform Elevation
Equipment Platform Elevation
Support No.
Reducing Item
Valve No.
Instrument Item
Special Item
Accessory Data - Select accessory data to be displayed in below categories. To refer to details of each item, see Option (on page 45). Common Option
Drawing No. (Title Block)
Drawing NO. (Reference)
Drawing Title
Drawing Notes
Drawing Scale
Drawing Revision No. (Title Block)
Drawing Revision No. (Reference)
Match Drawing No.
Deck Height
External Dimension Text
Internal Dimension Text
Match Line Coordinates
North Mark
Key Plan
External Dimension Line
External Dimension Lead Line
Match Line
Internal Dimension Line
External Label Lead Line
Plant Design System (PDS) Ortho Draw User's Guide
37
Settings Piping Option
Flow Mark
Arrow Mark
Dot Mark
Hatching Mark
Support Mark
Structure Platform Mark
Equipment Platform Mark
Ref. Equipment Mark
Pipe Center Line
Equipment Center Line
Nozzle Center Line
Chart - Select a chart to be displayed in below categories. To refer to details of each item, see Chart in Piping Option (on page 59).
Revision History Chart
Nozzle Chart
Ref. Equipment Chart
See Also Generation Setting (on page 34)
Generation Setting - HVAC Selecting Setting > Generation Setting > HVAC or clicking allows the On/Off of HVAC Drawing items in the same manner as the Piping case. For more information, see Generation Setting - Piping (on page 36) Label - Select a label to be displayed in below categories by Plan View, Section View, and ISO View. When you place structural labels on Piping, HVAC, and Electrical, the sparse structural model is attached to the drawing view or to the model in PDS. Also, the propagated model (PRP file) is attached only for graphics; ortho extracts data for label placement from sparse (.DGN) model. To refer to details of setting an item, see Label Definition in HVAC Option (Jump Template) (see "HVAC Option" on page 93).
38
Duct Size Label
Elevation Label
Piece No.
Equipment No.
Plant Design System (PDS) Ortho Draw User's Guide
Settings
Inline Equipment Item
Instrument Item
Seat No.
Structure Grid
Structure Grid Coordinates
Structure Member Section
Support No.
Accessory Data - Select accessory data to be displayed in below categories. To refer to details of setting an item, see Label Definition in HVAC Option (on page 93) . Common Option
Drawing No. (Title Block)
Drawing NO. (Reference)
Drawing Title
Drawing Notes
Drawing Scale
Drawing Revision No. (Title Block)
Drawing Revision No. (Reference)
Match Drawing No.
Deck Height
External Dimension Text
Internal Dimension Text
Match Line Coordinates
North Mark
Key Plan
External Dimension Line
External Dimension Lead Line
Match Line
Internal Dimension Line
External Label Lead Line
HVAC Option
Equipment Center Line
Up Down Mark
Arrow Mark
Dot Mark
Chart - Select a chart to be displayed in below categories. To refer to details of each item, see Chart in HVAC Option (on page 93).
Plant Design System (PDS) Ortho Draw User's Guide
39
Settings
Revision History Chart
Main Equipment Chart
Inline Equipment Chart
Instrument Chart
Seat Chart
Support Chart
See Also Generation Setting (on page 34)
Generation Setting - Electrical If the user selects Setting > Generation Setting > Electrical or clicks , the displayed categories of the electrical drawing can be On or Off as piping. For more information, see Generation Setting - Piping (on page 36) Label - Select a label to be displayed in below categories by Plan View, Section View, and ISO View. When you place structural labels on Piping, HVAC, and Electrical, the sparse structural model is attached to the drawing view or to the model in PDS. Also, the propagated model (PRP file) is attached only for graphics; ortho extracts data for label placement from sparse (.DGN) model. To refer to details of each item, see Option (on page 45).
Tray Label
MCT Label
Elevation Label
Ref. Equipment Label
Main Equipment Label
Item No.
Seat No.
Structure Grid
Structure Grid Coordinates
Structure Member Section
Support No.
Accessory Data - Select accessory data to be displayed in below categories. To refer to details of each Item, see Label Definition in . Electrical Option (on page 113) Common Option
40
Drawing No. (Title Block)
Drawing No. (Reference) Plant Design System (PDS) Ortho Draw User's Guide
Settings
Drawing Title
Drawing Notes
Drawing Scale Text
Drawing Revision No. Text
Match Drawing No.
Deck Height
External Dimension Text
Internal Dimension Text
Match Line Coordinates
North Mark
Key Plan
External Dimension Line
External Dimension Lead Line
Match Line
Internal Dimension Line
External Label Lead Line
Electrical Option
Equipment Center Line
Up Down Mark
Arrow Mark
Dot Mark
Ref. Equipment Mark
Chart - Select a chart to be displayed in below categories. To refer to details of each item, see Chart in Electrical Option (on page 113) .
Revision History Chart
Tray BOM Chart
Support Chart
Ref. Equipment BOM Chart
See Also Generation Setting (on page 34)
Plant Design System (PDS) Ortho Draw User's Guide
41
Settings
42
Plant Design System (PDS) Ortho Draw User's Guide
SECTION 5
Drawing This section focuses on creating drawings.
In This Section Generation Drawing....................................................................... 43 View Drawing................................................................................ 43 Update Drawing ............................................................................. 44
Generation Drawing Create a drawing after finishing generation setting of disciplines and option setting. After checking on the Drawing or the View to be produced, and selecting for each Discipline on Drawing > Generate or clicking items, and right clicking to display the menu.
or selecting a Drawing's checkbox of the Tree
To create a drawing, you must select a discipline suitable for the checked drawing and view.
See Also Drawing (on page 43)
Plant Design System (PDS) Ortho Draw User's Guide
43
Drawing
View Drawing If the user selects View Drawing in Drawing > Generate, or clicks will be shown.
, the created drawing
If View Drawing is processed, then the Drawing that has been selected with the mouse will be opened without having to check the checkbox.
See Also Drawing (on page 43)
Update Drawing If only the corresponding Drawing is updated and run, then it will be prompted whether to delete and re-receive the User Input Data.
See Also Drawing (on page 43)
44
Plant Design System (PDS) Ortho Draw User's Guide
SECTION 6
Option Piping, Steel Structure, HVAC, and Electric Cable Tray Layout Drawing are of the traditional drawing expression methods. This causes them to have a different orientation of the content depending on each company and project, which asks for various drawing structures. This section describes the method for producing an optimal drawing in such a diverse situation and explains User Customization.
In This Section Common Option ............................................................................ 45 Piping Option ................................................................................. 59 HVAC Option ................................................................................ 93 Electrical Option ............................................................................ 113 Structure Grid Data Option ............................................................ 126
Common Option Common Option includes the common options that are used for producing the drawing of Piping, HVAC, and Tray.
Plant Design System (PDS) Ortho Draw User's Guide
45
Option To set Common options, go to Option menu > Select Common, or click
in the toolbar.
Option Profile - Save it by clicking Save after changing options. The present category can be initialized by clicking Get Default.
See Also Option (on page 45)
46
Plant Design System (PDS) Ortho Draw User's Guide
Option
PCS Monument Tab (Common Options Dialog Box) It is possible to shift the coordinates according to the user’s preference through the Plant Coordinate System Monument. It is displayed as the sum after adding the value entered in Easting, Northing, and Elevation. In Coordinate Prefix, the prefixes of the items (Clipping Coordinates, Match Line Coordinates etc.) marking the coordinates are set for each direction.
Unit Tab (Common Options Dialog Box) Sub Unit - Sets the sub units for the drawing. Model Bore Unit - Sets the size of the pipe and duct which will be displayed on the drawing. Drawing Bore Unit - Sets size of the pipe and duct which will be displayed on the drawing. It supports metric and English unit. Distance Unit - Sets dimension unit to be displayed on the drawing. It supports metric and English unit. If English unit is selected, the user can set precision and display additionally. Piping Dia Table - The user can select the OD(Outer Diameter) Table to calculate BOP of the pipe to be displayed on the drawing.
Plant Design System (PDS) Ortho Draw User's Guide
47
Option ANSI and JIS are initially provided, and the user can create an user management table.
48
Plant Design System (PDS) Ortho Draw User's Guide
Option
Symbology Tab (Common Options Dialog Box) Sets property of the label and dimension to be displayed on the drawing. It is categorized into Label, Text, Line, and Symbol.
Label It can define property of the label to be drawn on the drawing. It can define Match Line Coordinates in Common Option, and can set Level, Color, Weight, Font, Width, Line Style, Style, Style Clearance, and Lead Line From.
Style - Outline of the label
Style Clearance - Space between style and label
Lead Line From - If the distance between tag and the point to be marked is larger than the value set , lead line will be displayed.
Plant Design System (PDS) Ortho Draw User's Guide
49
Option
Text You can set level, color, weight, font, and height, and width of the text to be used for the drawing.
50
Drawing No.(Title Block) - Sets property of the drawing No. within the title block on the bottom right of the drawing.
Drawing No.( Reference) - Sets property of the drawing No. on the top left of the drawing.
Drawing Title - Sets property of the drawing title of the general information.
Drawing Notes - Sets property of the drawing note.
Drawing Scale Text - Sets property of the text to indicate scale of the drawing.
Drawing Revision No. Text - Sets property of the Revision No. that was entered in Revision Status of the General Information.
Match Drawing No - Sets property of match drawing No.
Deck Height - Sets property of elevation of the view volume.
External Dimension Text - Sets property of the dimension text to be displayed externally.
Revision History Chart Text - Sets property of the text to be used for Revision History Chart.
Internal Dimension Text - Sets property of the Dimension Text to be displayed internally. Plant Design System (PDS) Ortho Draw User's Guide
Option
Line You can define property of the lines to be used for the drawing. The user can define External Dimension Line, External Dimension Lead Line, Match Line and Revision History Chart Line, Internal Dimension Line, and External Label Lead Line through Common Option, and level, color, weight, line style are all definable properties.
Plant Design System (PDS) Ortho Draw User's Guide
51
Option
Symbol You can set level of North mark and key plan to be used for the drawing.
52
Plant Design System (PDS) Ortho Draw User's Guide
Option
Location Tab (Common Options Dialog Box) The user allocates categories to be displayed on the drawing. After setting the coordinates, the text that are not cells can be set to either Left, Center, or Right column.
Plant Design System (PDS) Ortho Draw User's Guide
53
Option
Dimension Tab (Common Options Dialog Box)
Rectangular View. - Sets range and alignment of the dimension and the label in Rectangular View including Composite View. The user can select and set Millimeter and Percentage as range in External Range Unit. Dimension included in Range and label are displayed outside View. The External Label Alignment can be set for each of the four directions of View. Inside is set basing the inside as standard, and outside is set basing the outside as standard. Circular View - The user sets dimension, and range of the label and alignment in Circular View. Dimension Distance - The user sets the minimum distance in Minimum Model Dimension Distance to indicate dimension. If the Distance Style is set to Suppress, then the dimensions below the minimum distance will be omitted. If it set to Sum, then all the omitted Dimensions will be summed.
54
Plant Design System (PDS) Ortho Draw User's Guide
Option
Symbol Tab (Common Options Dialog Box) The user can set a cell name to be used in the drawing and can set scale. Symbol Name must be set as Cell name to be used in the drawing.
Plant Design System (PDS) Ortho Draw User's Guide
55
Option
56
Plant Design System (PDS) Ortho Draw User's Guide
Option
Chart Tab (Common Options Dialog Box) The user can set Revision History Chart that the user reports alternations on the drawing. The name of the column to be displayed on the chart can be written in the Header, the column’s width can be set in Width, and the column’s left/center/right columns can be set on Justification.
Plant Design System (PDS) Ortho Draw User's Guide
57
Option
Misc Tab (Common Options Dialog Box) Slope Line Slope Line Cutoff Ratio - Enter the maximum value of a Slope Line. If the slope is below the entered value, then the Working Point Elevation and Slope Mark is displayed. If Fraction is selected, then the Slope Rate displayed on the Slope Mark is shown as a fraction, and if Decimal is selected, then it is shown as a decimal value. If Angle is selected, then it is shown as a angle value.
Coordinates Select direction of Match Line Coordinate and Structure Grid Coordinates.
58
Plant Design System (PDS) Ortho Draw User's Guide
Option If Auto is checked, direction of Structure Grid Coordinates is selected automatically.
Piping Option Sets text, mark, chart, and drawing settings, elevation, and dimension to be used to create a piping drawing. You can access these options either through Main > Option > Piping menu, or by clicking
in the toolbar.
See Also Option (on page 45)
Plant Design System (PDS) Ortho Draw User's Guide
59
Option
Range Tab (Piping Option Dialog Box) Defines ranges for labels and dimensions.
External Dimension, Internal Dimension - Sets range of pipe size to indicate External Dimension and Internal Dimension. External Pipe Line Label, Internal Pipe Line Label - Sets range of pipe size to indicate External Pipe Line Label and Internal Pipe Line Label. Flow Mark - Sets range of pipe size to indicate Flow mark. Nozzle Tag - Sets range of pipe size to indicate Nozzle Tag. Pipe Center Line - Sets range of pipe size to indicate Pipe Center Line.
60
Plant Design System (PDS) Ortho Draw User's Guide
Option
Elevation Tab (Piping Option Dialog Box) Defines settings for elevation drawings.
Elevation Style - The standard of elevation is set in Elevation Style. It supports System, User Define Elevation, and User Deck Elevation.
System - Uses elevation of the model.
User Define Elevation - The elevation that user defined is used as the standard elevation.
User Deck Elevation - It is formed of multiple layers of decks the user has entered into the User Define Deck Table.
Plant Design System (PDS) Ortho Draw User's Guide
61
Option User Deck Elevation displays the elevation with the deck included in the View Boundary out of the Decks entered by the user into the User Define Deck Table as the standard. The lowest Elevation out of the included Deck will become the Lower Deck, and the highest Deck will become the Upper Deck. The Deck serving as the standard will be set according to the User Define Deck Style set by the Expression Style.
If it is set as Near Deck, then the closest Deck out of Upper and Lower Decks will be automatically selected. Display the system standard’s elevation and Outside of Deck if the elevation is located under the Lower Deck after setting the Elevation located above the Upper Deck. If the Deck included in the View Boundary does not exist, then an error message will be displayed, and if only one of the Decks is included, then the elevation will be displayed as shown on the Elevation Style box. Elevation Expression Style - Select elevation style among TOP, COP, and BOP. Elevation Description - Set Prefix and Suffix to be displayed in Elevation.
Condition Tab (Piping Option Dialog Box) Sets conditions so that the necessary Model out of the Reference File can be selected. Criteria are of the same method as the Criteria used in Label Format, the And condition can be set for the same Row, and if a Row is added, then the OR condition is formulated. The condition written in the Criteria is the file name of the Reference File excluding the expansion. In Criteria, signs such as ‘*’, ‘?’ and ‘!’ are used. ‘*’ : It does not figure the letters in the direction of the symbol regardless of the number. ‘?’ : It does not figure the letters identical to the number.
62
Plant Design System (PDS) Ortho Draw User's Guide
Option ‘!’ : It figures the conditions inversely.
If the same condition as the picture above is given, then it will become (*PIPE* & ??EQUI*) | (*HVAC*). Thus if ‘EQUI’ is present on the third character of the file name, or if the file name includes ‘PIPE’ or ‘HVAC’, then it means that they do not meet the conditions.
Piping Model Rule If all reference files are allowed, for instance like ‘*’, then all files for piping also will be allowed in Drawing Manager. If the user does not input any value, then no file for piping will not be applied in Drawing Manager.
Equipment Model Rule If all Reference Files are allowed to set the Criteria as ‘*’, then all files made by the Drawing Manager for Equipment Use are permitted, and if no value is written, then all files made by the Drawing Manager for Equipment use will not be permitted.
Plant Design System (PDS) Ortho Draw User's Guide
63
Option Equipment Model Rule includes the Generic Equipment and Ref. Equipment Model Rule. The thing to watch out for here is that there is a ranking. One Model only has one Model Rule applied, thus if the same Criteria is applied on two Model Rules, then the corresponding drawing will be recognized as a Generic Equipment. If the Criteria is set as ‘*’ for Generic Equipment, then all drawings will not be applied in the Ref. Equipment, so cautions must be taken.
Support Model Rule Piping Support Designer in PDS - The Piping Drawing’s Support can be modeled into 3 types. If it is modeled in PDS, then the data is saved in pdtable_80. Thus the Model Rule is applied in the same manner as Pipe Model Rule, and in this case, changes cannot be made. Whether to display this Support on the drawing can be set with the use of ‘Use Piping Support Designer in PDS’ checkbox. If used, then the Data Column to be displayed on the Drawing can be set from the Column Name beneath. When setting it as Key-in, it is possible for the user to manually enter is, but the exact Column must be set to display the data, so accuracy is required.
64
Plant Design System (PDS) Ortho Draw User's Guide
Option It is possible to combine columns if Advanced is selected.
FrameWorks+ - FrameWorks Plus Support Model Rule and Structure Model Rule will be applied with priority order.
Plant Design System (PDS) Ortho Draw User's Guide
65
Option In other words, the drawing applied to FrameWorks Plus Support Model Rule will not be applied to Structure Model Rule.
Attribute Name - Sets attribute to group supports among attribute names in the Support Model that was modeled with FrameWorks+.
66
Plant Design System (PDS) Ortho Draw User's Guide
Option Pelican Forge - Sets a model that was modeled with Pelican Forge.
Column Name for Support - Sets a column name of the data to be displayed in Support in the drawing.
Plant Design System (PDS) Ortho Draw User's Guide
67
Option
Structure Model Rule Structure Model Rule use the same Discipline as FrameWorks Plus Support Model Rule, thus priority order is applied. Since FrameWorks Plus Support is prioritized, the FrameWorks Plus Support Model Rule must be blocked or the drawing name to be applied on the Structure Model Rule must be set in such a way so that that it is not be the same as the FrameWorks Plus Support Model Rule in order to properly apply the Structure Model Rule.
Structure Platform Rule - In the model that structure model rule was applied, set platform to be displayed on the drawing. Apply the FrameWork+ member’s name after comparing it with the criteria entered by the user. Type - The user can select WALL or SLAB as attribute type in FrameWorks Plus. If the user selects ‘ALL’, both of SLAB and WALL will be selected. Criteria - Sets it as only the attribute name set by the user Attribute can be selected. It is applied as criteria of the model rule is applied.
68
Plant Design System (PDS) Ortho Draw User's Guide
Option
Label Tab (Piping Option Dialog Box) Label Definition Sets table name and column name of the data to be displayed as label or tag in the Piping Drawing (except Structure Column, Support No) The user can select the table and the column used in PDS, and alter the label. But if the user enters a wrong value, invalid data value will be displayed, otherwise no drawing will be created. Thus, the user must understand appropriate value for the tables and columns before applying it.
Pipe Line No. - Sets data of the Pipe Line No. to be inserted in Pipe Line Label. (See Label Expression.) Clipped Coordinates - It is used to mark coordinates when the end row of the pipe in the Plan Drawing was clipped by the view limits. (No options in the Label Format) Elevation Label - It is the label to be used to mark Pipe elevation in the drawing. (No options in the Label Format) Working Point Elevation - It is the label to be used to mark elevation in Working Point in the Slope Line. (No options in the Label Format)
Plant Design System (PDS) Ortho Draw User's Guide
69
Option Pipe Spool No. - Sets data of the Spool No. to be inserted in the Pipe Spool No. Label. (See Label Expression) Ref. Equipment No. - Reference Equipment is an additional equipment which is not influential on the drawing. Sets data to be displayed as Reference Equipment No. (See Label Expression) Equipment No. - Sets data to be displayed as Equipment No. (See Label Expression) Equipment Nozzle No. - Sets data to be displayed as Equipment Nozzle No. Structure Column - There are ‘Grid Text’ and ‘Grid Model’ in the table in the Structure Column category. Grid Text is the grid that the user keyed-in the Structure Grid Data, and Grid Model is the data which was brought from the Grid Model generated with FrameWorks+. The user must be cautious to attach not only the Grid Model as reference file, but also Propagated Model and Sparse Model. The user can get the optimal results when he combines two models since Sparse model is used to call for data while Propagated model is used to create a drawing in e-Draw. There are three options such as All, Grid Intersection, and Grid Intersection + Column Position in column. If the user selects All, all Grid lines in the data will be displayed on the drawing. If the user selects Grid Intersection, only crossed-over grids will be displayed. If the user selects Grid Intersection + Column Position, then the grids with a column at the intersection will be displayed Structure Column Coordinates - Displays coordinates in the Structure Column. (no options in the Label Format) Structure Member Section - Selects Type or Name, or Section which are attributes of the FrameWorks+ to be displayed as Structure Member Section. Structure Platform Elevation - Mark the platform elevation which was modeled as Structure on the drawing. (no options in the Label Format) Equipment Platform Elevation - Displays the Platform elevation on the drawing, which was modeled as Equipment. (no options in the Label Format) Support No. - Support No. is automatically extracted from the reference file that the user set in the Condition, expressed and displayed in Support which was modeled as pdtable_80, FrameWorks+, and Pelican Forge. ECC. Reducing Item / CON. Reducing Item - Sets data to be displayed as Reducing Item. The data set in Model_code/Commodity_code within the Column Data is displayed as the label. Valve No. - Sets data to be displayed as Valve No. The data set in Model_code/Commodity_code within the Column data is displayed as the label. Instrument Item - Sets data to be displayed in the Instrument Item. The data set in Model_code/Commodity_code within the Column data is displayed as the label. Special Item - Sets data to be displayed in the Special Item. The data set in Model_code/Commodity_code within the Column data is displayed as the label.
70
Plant Design System (PDS) Ortho Draw User's Guide
Option
Label Format Process the data set in Label Definition.
Criteria - It is an option to be used for labeling and tagging the part appropriate for specific conditions. (ex. *pipe* creates a label or a tag regardless of the letters before or behind ‘pipe’. ‘*’ : It does not figure regardless of the number. ‘?’ : It does not figure the letters identical to the number. ‘!’ : It figures the conditions inversely. Delimiter - The letters defined by Delimiter is selected when generate it , and it is applied same as Order. Order - Selects one among the sentences categorized by Delimiter. If no value is entered, it will regard Delimiter as CR/LF(Carriage Return and Line Feed). Omission - A symbol to indicate the start point and the end point of the part to be omitted in Tag or Label must exist as a pair. If it is not a pair, it should not be applied. Prefix - Sets Prefix to be displayed before the label or tag.
Plant Design System (PDS) Ortho Draw User's Guide
71
Option Suffix - Sets Suffix to be displayed next to the label or tag.
Label Expression Defines a form of the Label.
This category is divided into Internal Label and External Label in which Label is consisted of Pipe Line No. Elevation, and Coordinate. Depending on the user`s choice, the label can be one line or two lines. The user can input a letter or space between the categories.
72
Plant Design System (PDS) Ortho Draw User's Guide
Option The following figures show the results generated by these settings:
If the second line of the adjacent Pipe label is identical, it is displayed in binding. The following figure shows the result of the bound two pipe line labels which are the same.
Internal Label Type - The user can set pipe label to consist in View and can select one line or two line. Label can be consisted of Pipe Line No., Elevation, and/or Description (optional), and the user can put the user string between them. External Label Type - The user can set pipe label to consist in View and can select one line or two line. Label can be consisted of Pipe Line No., Elevation, and/or Description (optional), and the user can put the user string between them.
Plant Design System (PDS) Ortho Draw User's Guide
73
Option Advanced Setting - Click Advanced button on the right side to compose more complicated label.
If the user clicks Add button on above box, one more line will be added and two lines are shown. The user can set Label format for the selected categories as DB attribute in this box. Pipe Spool No. Label - It constitutes the Spool No. Label and it is consisted of a single line. Label can be consisted of the Spool No and the pdtable_34 column and the user can put the user string between them. Equipment Label - The user can set Main Equipment Label and Reference Equipment Label, and select One Line or Two Line. Label can be consisted of two elements among Equipment No., Elevation, and Description, and the user can put the user string between them. Main Equipment Label Type is optional with Internal Fixed Line External Fixed Line, and Helix.
74
None - Do not perform white space search
Helix - Displays it in the nearest space.
Internal Fixed Line - Displays it horizontally in the drawing.
External Fixed Line - Displays it horizontally, outside the drawing.
Plant Design System (PDS) Ortho Draw User's Guide
Option
Symbology Tab (Piping Option Dialog Box) Label Sets symbology of the tag or label which are used for piping drawing. The user can set Level, Color, Weight, Font and Width, Line Style, Style and Style Clearance, and Lead Line From. Level, Color, Weight, and Font are the same as the value used in MicroStation.
Style - Boxing of the Label.
Plant Design System (PDS) Ortho Draw User's Guide
75
Option
76
None - Draws Lead line only in the tag.
Under Line - Draws Under line together with Lead line in the tag.
Square Box - Draws a square box with the lead line in the tag.
Balloon - Draws a balloon with the lead line in the tag.
Rounded Box - Draws a rounded box with the lead line in the tag.
Plant Design System (PDS) Ortho Draw User's Guide
Option
Hexagonal Box - Draws a hexagonal box with the lead line in the tag.
Diamond Box - Draw diamond box with lead line in the tag.
Fixed Type - Box and Balloon can be larger depending on the text size, but the fixed type cannot be altered. The size can be adjusted through only Style Clearance.
Style Clearance - Space between Style and Label. Lead Line From - If the distance between tag and the point to be marked is larger than the value set, lead line must be marked.
Plant Design System (PDS) Ortho Draw User's Guide
77
Option
Text Sets property of the mark text and the chart text which are used in Piping Drawing.
78
Plant Design System (PDS) Ortho Draw User's Guide
Option
Line Sets property of the line to be used in Piping Drawing.
Plant Design System (PDS) Ortho Draw User's Guide
79
Option
Symbol Sets level of the symbol mark to be used in Piping Drawing.
80
Plant Design System (PDS) Ortho Draw User's Guide
Option
Location Tab (Piping Option Dialog Box) Sets location of the Nozzle Chart and the Ref. Equipment Chart. The standard position of the Chart is the top right in the chart.
Plant Design System (PDS) Ortho Draw User's Guide
81
Option
Dimension Tab (Piping Option Dialog Box) External Dimension Dimension is basically displayed in four steps such as Overall Dimension, Structure Grid Dimension, Structure / Equipment Dimension, and Pipe Dimension. If the checkbox on the right is checked, dimension will be displayed. If not, the selected dimension layer will be disappeared. Thus, externally displayed Pipe line label also will automatically move to the direction of the match line. It is the value from (A) to (Q), the interval between one and another can be adjusted as shown.
82
Plant Design System (PDS) Ortho Draw User's Guide
Option
Internal Dimension
Internal Dimension Criteria - The user can select Column or Beam, or Equipment as a standard of Internal Dimension. Internal Dimension Object - The user can select Component, Support, or Piping Vertex as an object to generate an Internal Dimension. Internal Label Offset - Set distance between Internal Label text and line.
Plant Design System (PDS) Ortho Draw User's Guide
83
Option
Symbol Tab (Piping Option Dialog Box) Other Symbol Sets mark to be used in Piping Drawing.
Symbol Name - Inputs a cell name of the cell library file to be used in the chart. Scale - Sets symbol size to be displayed on the chart. Symbol Type - Some symbol is supported e-Draw’s draw mode not using cell. Select Draw symbol type. Set Shape, Pattern, Density, Outline. Density means this pattern’s line
84
Plant Design System (PDS) Ortho Draw User's Guide
Option
Ref. Equipment Symbol Sets symbol to be displayed in Reference Equipment.
Ref. Equipment Symbol Criteria - It is a function to choose an item in the Ref. Equipment that the symbol mark will be applied. Apply the symbol after matching the data value that was set in Label Definition with the value entered in the Ref. Equipment Symbol Criteria. It does not match the whole data, but compares the numbers of the letters entered in the Ref. Equipment Symbol Criteria. For example, if the user enters ‘S-001’ in the Ref. Equipment Symbol Criteria and there are three types of data value such as ‘S-0012’, ‘S-0022’, and ‘SP-001’, the item ‘LIGHT’ Symbol will be applied is ‘S-0012’. Finally, the item applied to the criteria is not applied to the next criteria. Ref. Equipment Symbol Name - Sets symbol mark to be used in the Ref. Equipment as Ref. Equipment Symbol Criteria. Equipment Symbol Description - When generating the Ref. Equipment Chart out, inputs description on this step. Scale - Sets size of the symbol mark to be displayed on the drawing.
Plant Design System (PDS) Ortho Draw User's Guide
85
Option
Support Symbol
Support Symbol Criteria - It is a function to choose an item in Support that symbol mark will be applied. Apply the symbol after matching the data value extracted from Label Definition with the value entered in Support Symbol Criteria. However, Prefix set through Label Format is not applied, and capital letters are distinguished from small letters. It does not match the whole data, but compares the numbers of the letters entered in Support Symbol Criteria. For example, if the user inputs ‘SP1’, ‘SP2’, and ‘SP3’ in Support Symbol Criteria and there are three types of data values such as ‘SP12’, ‘SP22’, and ‘SP30’, the item ‘SUPP1’ symbol mark will be applied is ‘SP12 while the item that ‘SUPP2’ Symbol Mark will be applied, is ‘SP22’ as ‘SUPP3’ to ‘SP30’. Lastly, the item that was applied to the criteria, should not be applied to the next criteria. Support Symbol Name - Sets symbol mark to be used in Support as Support Symbol Criteria. Scale - Sets size of the symbol mark to be displayed on the drawing.
86
Plant Design System (PDS) Ortho Draw User's Guide
Option
Platform Symbol
Symbol Name - Inputs a cell name of the cell library file to be used in the chart. Scale - Sets symbol size to be displayed on the chart. Symbol Type - Platform symbol is supported e-Draw’s draw mode not using cell. Select Draw symbol type. Set Shape, Pattern, Density, Outline. Density means this pattern’s line
Plant Design System (PDS) Ortho Draw User's Guide
87
Option
Chart Tab (Piping Option Dialog Box) Defines the settings for the Nozzle and Reference Equipment charts to be used in the Piping Drawing.
Nozzle Chart
Chart Type - The user can select Group Type or General Type. If the name of the Group Type is same, indicate it as one group. General type will be indicated without rows for group. Maximum Row - Specifies the maximum number of the rows in the chart. If the displayed number is larger than the maximum number, it will be repeatedly displayed on the left in the chart. Header Count - Specifies the number of the rows in the chart. The user must set undefined categories as ‘none’ because the drawing can occur an error if the user creates a drawing with the empty row which was created by extending count. Row Height - Sets height of the rows. Group - Text to be displayed as supreme when the chart type is Group.
88
Plant Design System (PDS) Ortho Draw User's Guide
Option Header - Sets column text to be displayed in the front row in the chart. Width - Sets width of the rows in the chart. Justification - Sets alignment of the rows as right alignment or left alignment, or center alignment. Table Name - Sets table name of the data to be displayed on the chart. Column Name - Sets column name of the data to be displayed on the chart.
Ref. Equipment BOM Chart
Maximum Row - Defines the maximum number of the rows in the chart. If the displayed number is larger than the minimum, it will be repeatedly displayed on the left in the chart. Header Count - Specifies the number of the rows in the chart. The user must set undefined categories as ‘none’ because the drawing can occur an error if the user creates a drawing with the empty row which was created by extending count. Row Height - Sets height of the rows. Header Type - Sets features of the rows in the chart.
TYPE - If ‘type’ is set in the Ref. Equipment BOM Chart, the mark set in Ref. Equipment Symbol will be displayed and a chart will be created based on this mark..
Plant Design System (PDS) Ortho Draw User's Guide
89
Option
DESCRIPTION - If ‘description’ is set in the Ref. Equipment BOM Chart, the description set in Ref. Equipment Symbol will be displayed. (Grouping using this category is recommended.)
STRING - It means the general letters, and it is used for text column in the chart.
NUMBER - The number identical to weight is set in Column, and it is displayed on the chart after accumulating by group.
QUANTITY - If it is set as ‘QUANTITY’, grouping order, table name, and column name are altered to ‘Disabled’. Then, quantity will be automatically calculated and will be displayed in the chart.
Header - Sets text to be displayed in the front row in the chart. Grouping Order - Sets the priority order for grouping. Width - Sets width of the rows in the chart. Justification - Sets alignment of the rows as right alignment, or left alignment, or center alignment. Table Name - Sets data table name to be displayed on the chart. Column Name - Sets column name of the data to be displayed on the chart.
90
Plant Design System (PDS) Ortho Draw User's Guide
Option
Report Tab (Piping Option Dialog Box) Defines the settings for pipeline, support, speciality item, instrument item, equipment, and equipment nozzle reports used in the Piping Drawing.
Pipeline Report Make Pipeline Report - Select this option to generate a pipeline report using the attributes that you define. Header Name - Defines the text to display for the column heading. Header Type - Select the data type that you want to display in the column. If you select DB, the software displays the database attributes that are available. Attribute - Select the data attribute that you want to display in the column. If you selected DB in the Header Type, then the database attributes from pdtable_12_xxx in the dd schema are displayed. (PDS Ortho Draw reads the design.dll file that you specified in the Environment (on page 26) dialog box for the attributes.) Sort Order - Select the first, second, and third columns that you want the report sorted by. If you do not want the reported sorted on a column, select None for that column.
Plant Design System (PDS) Ortho Draw User's Guide
91
Option
Support Report Make Support Report - Select this option to generate a support report using the attributes that you define. Header Name - Defines the text to display for the column heading. Header Type - Select the data type that you want to display in the column. Attribute - Select the data attribute that you want to display in the column. Sort Order - Select the first, second, and third columns that you want the report sorted by. If you do not want the reported sorted on a column, select None for that column.
Special Item, Instrument Item Report Make Special Item Report - Select this option to generate a speciality item report using the attributes that you define. Make Instrument Item Report - Select this option to generate an instrument item report using the attributes that you define. Header Name - Defines the text to display for the column heading. Header Type - Select the data type that you want to display in the column. Attribute - Select the data attribute that you want to display in the column. Sort Order - Select the first, second, and third columns that you want the report sorted by. If you do not want the reported sorted on a column, select None for that column.
Equipment, Equipment Nozzle Report Make Equipment Report - Select this option to generate an equipment report using the attributes that you define. Make Equipment Nozzle Report - Select this option to generate an equipment nozzle report using the attributes that you define. Header Name - Defines the text to display for the column heading. Header Type - Select the data type that you want to display in the column. Attribute - Select the data attribute that you want to display in the column. Sort Order - Select the first, second, and third columns that you want the report sorted by. If you do not want the reported sorted on a column, select None for that column.
92
Plant Design System (PDS) Ortho Draw User's Guide
Option
HVAC Option Sets text, mark, chart, drawing setting, and dimension that are needed to create a HVAC Drawing. It can be set through Main > Option > HVAC menu, or by clicking
in the toolbar.
See Also Option (on page 45)
Elevation Tab (HVAC Option Dialog Box) Defines settings for elevation drawings.
Plant Design System (PDS) Ortho Draw User's Guide
93
Option Elevation Style - The standard of elevation is set in Elevation Style. It supports System, User Define Elevation, and User Deck Elevation.
System - Uses elevation of the model.
User Define Elevation - The elevation that user defined is used as the standard elevation.
User Deck Elevation - It is formed of multiple layers of decks the user has entered into the User Define Deck Table.
User Deck Elevation displays the elevation with the deck included in the View Boundary out of the Decks entered by the user into the User Define Deck Table as the standard. The lowest Elevation out of the included Deck will become the Lower Deck, and the highest Deck will become the Upper Deck. The Deck serving as the standard will be set according to the User Define Deck Style set by the Expression Style.
If it is set as Near Deck, then the closest Deck out of Upper and Lower Decks will be automatically selected. Display the system standard’s elevation and Outside of Deck if the elevation is located under the Lower Deck after setting the Elevation located above the Upper Deck. If the Deck included in the View Boundary does not exist, then an error message will be displayed, and if only one of the Decks is included, then the elevation will be displayed as shown on the Elevation Style box. Elevation Expression Style - Select elevation style among TOP, COP, and BOP. Elevation Description - Set Prefix and Suffix to be displayed in Elevation.
94
Plant Design System (PDS) Ortho Draw User's Guide
Option
Condition Tab (HVAC Option Dialog Box) As described in Piping Option, there is the property order in the model rule. In case of HVAC Option, Equipment, Instrument and Seat, Support, and Structure are applied in the property order even though the same model rule is applied to all of them. Equipment > Instrument Seat > Support > Structure For example, the drawing must be input as structure to display grid information. If it is applied to the seat model rule, you cannot get the needed information. Thus, you must understand features of the model rule and apply the priority order in an appropriate way to create a desired drawing.
Equipment Model Rule
It is a setting for the equipment model. If the user inputs ‘*’ in Criteria in all reference files, all attached files for equipment will be allowed while no attached file will be applied in Drawing Manager if the user does not input any value.
Plant Design System (PDS) Ortho Draw User's Guide
95
Option In Electrical Drawing, the priority order is applied to Equipment Model Rule and Instrument Model Rule. Since only one model rule is applied to one model, the model will be identified as Equipment if one criteria is applied to two model rules. If the criteria is set as ‘*’ in Equipment, the drawing is not applied to Instrument Model Rule.
Structure Model Rule Structure Model Rule use the same Discipline as FrameWorks Plus Support Model Rule, thus priority order is applied. Since FrameWorks Plus Support is prioritized, the FrameWorks Plus Support Model Rule must be blocked or the drawing name to be applied on the Structure Model Rule must be set in such a way so that that it is not be the same as the FrameWorks Plus Support Model Rule in order to properly apply the Structure Model Rule.
Structure Platform Rule - In the model that structure model rule was applied, set platform to be displayed on the drawing. Apply the FrameWork+ member’s name after comparing it with the criteria entered by the user. Type - The user can select WALL or SLAB as attribute type in FrameWorks Plus. If the user selects ‘ALL’, both of SLAB and WALL will be selected. Criteria - Sets it as only the attribute name set by the user Attribute can be selected. It is applied as criteria of the model rule is applied.
96
Plant Design System (PDS) Ortho Draw User's Guide
Option
HVAC Model Rule It is a setting for the HVAC Model. It is applied as other model rules are applied.
Plant Design System (PDS) Ortho Draw User's Guide
97
Option
Instrument Model Rule It is a setting for the Instrument Model. It is applied as other model rules are applied.
98
Plant Design System (PDS) Ortho Draw User's Guide
Option
Seat & Support Model Rule
FrameWorks+ - The priority against structure is described in FrameWorks Plus Support in Condition Tab (see "Condition Tab (Piping Option Dialog Box)" on page 62). Seat was also modeled in FrameWorks Plus, and it does not have a significant difference with support. Seat is prior to support, and support is prior to structure as shown below. Seat > Support > Structure
Attribute Name - Sets attribute to group seat with supports.
Pelican Forge - See Condition Tab (see "Condition Tab (Piping Option Dialog Box)" on page 62).
Plant Design System (PDS) Ortho Draw User's Guide
99
Option
Label Tab (HVAC Option Dialog Box) Label Definition Sets data table and column to be displayed as label or tag in the HVAC Drawing. (except Auto, Structure Column, and Support No.) The user can select table and column to be used in PDS and alter the label. However, if the user inputs a wrong value, invalid data value will be displayed or no drawing will be created. Thus, the user must understand and apply appropriate table and column value.
Duct Size Label (Width) - Sets data to be displayed as width of the duct. Duct Size Label(Depth) - Sets data to be displayed as depth of the duct. Elevation Label - Sets data to be displayed as elevation in HVAC. The user can select System or User Define Elevation, or User Deck Elevation in Elevation tab. Piece No. - Sets data of the Piece No. to be displayed as ID in HVAC. Equipment No. - Sets data to be displayed in Equipment No. Inline Equipment Item - Sets data to be displayed in Inline Equipment Item. Instrument Item - Sets data to be displayed in Instrument Item. 100
Plant Design System (PDS) Ortho Draw User's Guide
Option Seat No. - Sets data to be displayed in Seat. Seat which was modeled in FrameWorks+ is identical to support. The user can decide if he/she will define the identical element as support or as seat in the coming Condition. Structure Column - There are Grid Text and Grid Model. Grid Text is the grid that the user keyed-in the Structure Grid Data, and Grid Model is the data which was brought from the Grid Model generated with FrameWorks+. The user must be cautious to attach not only the Grid Model as reference file, but also Propagated Model and Sparse Model. The user can get the optimal results when he combines two models since Sparse model is used to call for data while Propagated model is used to create a drawing in e-Draw. There are three options such as All, Grid Intersection, and Grid Intersection + Column Position in column. If the user selects All, all Grid lines in the data will be displayed on the drawing. If the user selects Grid Intersection, only crossed-over grids will be displayed. If the user selects Grid Intersection + Column Position, then the grids with a column at the intersection will be displayed. Structure Member Section - Select type or name, or section as the Beam and Column member. Support No. - Sets data to be displayed in support.
Plant Design System (PDS) Ortho Draw User's Guide
101
Option
Label Format Process the data set in Label Definition.
Criteria - It is an option to label or tag the categories conformable to specific conditions. (ex. With *pipe*, label or tag can be created regardless of the letter before or behind ‘pipe’. ‘*’ : It does not figure regardless of the number. ‘?’ : It does not figure the letters identical to the number. ‘!’ : It figures the conditions inversely. Delimiter - The letters defined in Delimiter are deleted when generate it, and it is applied as order is applied. Order - Selects a sentence among the sentences categorized by Delimiter. If no value is entered, it will regard Delimiter as a CR/LF(Carriage Return and Line Feed). Omission - A symbol to indicate the start point and the end point of the part to be omitted in Tag or Label must exist as a pair. If it is not a pair, it should not be applied. Prefix - Sets Prefix to be displayed before Label or Tag. Suffix - Sets Suffix to be displayed next to Label or Tag.
102
Plant Design System (PDS) Ortho Draw User's Guide
Option
Symbology Tab (HVAC Option Dialog Box) Label Sets symbology of tag or label to be used in HVAC Drawing. The user can set level, color, weight, and font and Width, Line Style, Style and Style Clearance, and Lead Line From. Level, color, weight, font are identical to the value used in MicroStation.
Style - Sets style to indicate the label. See 6.2.6.1 to refer to further information. Style Clearance - Space between Style and Label. Lead Line From - If the distance between tag and the point to be marked is larger than the value set, lead line must be marked.
Plant Design System (PDS) Ortho Draw User's Guide
103
Option
Text Sets level, color, weight, and font and height, and width of the mark text and the chart text that are used in HVAC Drawing.
104
Plant Design System (PDS) Ortho Draw User's Guide
Option
Line Sets level, color, weight, and line style to be used in HVAC Drawing.
Plant Design System (PDS) Ortho Draw User's Guide
105
Option
Symbol Sets level of the symbol mark to be used in the HVAC Drawing.
106
Plant Design System (PDS) Ortho Draw User's Guide
Option
Location Tab (HVAC Option Dialog Box) Sets location of the charts to be used in HVAC. The standard position is the top right of the chart.
Plant Design System (PDS) Ortho Draw User's Guide
107
Option
Dimension Tab (HVAC Option Dialog Box) External Dimension Dimension is basically displayed in four steps such as Overall Dimension, Structure Grid Dimension, Structure / Equipment Dimension, and Duct Dimension. If the checkbox on the right is checked, dimension will be displayed. If not, the selected dimension layer will be disappeared. Thus, externally displayed Pipe line label will also automatically move to the direction of the match line. It is the value from (A) to (Q), the interval between one and another can be adjusted as shown.
108
Plant Design System (PDS) Ortho Draw User's Guide
Option
Internal Dimension
Internal Dimension Criteria - The user can select Column or Beam, or Equipment as a standard of Internal Dimension. Internal Dimension Object - The user can select Component or Support, or HVAC Vertex as an object to generate Internal Dimension Internal Label Offset - Set distance between Internal Label text and line.
Plant Design System (PDS) Ortho Draw User's Guide
109
Option
Symbol Tab (HVAC Option Dialog Box) Other Symbol Sets symbol mark to be used in the HVAC Drawing.
Symbol Name - Inputs a cell name of the cell library to be used for drawing. Scale - Sets size to be displayed on the drawing
110
Plant Design System (PDS) Ortho Draw User's Guide
Option
Support Symbol Sets symbol mark to be displayed in Support.
Support Symbol Criteria - It is a function to choose an item in Support that symbol mark will be applied. Apply the symbol after matching the data value extracted from Label Definition with the value entered in Support Symbol Criteria. However, Prefix set through Label Format is not applied, and capital letters are distinguished from small letters. It does not match the whole data, but compares the numbers of the letters entered in Support Symbol Criteria. For example, if the user inputs ‘SP1’, ‘SP2’, and ‘SP3’ in Support Symbol Criteria and there are three types of data values such as ‘SP12’, ‘SP22’, and ‘SP30’, the ‘SUPP1’ symbol mark will be applied is ‘SP12 while the item that ‘SUPP2’ Symbol Mark will be applied, is ‘SP22’ as ‘SUPP3’ to ‘SP30’. Lastly, the item that was applied to the criteria, should not be applied to the next criteria. Support Symbol Name - Sets symbol mark to be used in Support as Support Symbol Criteria. Scale - Sets symbol mark size to be displayed on the drawing.
Plant Design System (PDS) Ortho Draw User's Guide
111
Option
Chart Tab (HVAC Option Dialog Box) Instrument Chart Maximum Row - Specifies the maximum number of the rows in the chart. If the displayed number is larger than the maximum, it will be repeatedly displayed on the left of the chart. Header Count - Specifies the number of the rows in the chart. The user must set undefined categories as ‘none’ because the drawing can occur an error if the user creates a drawing with the empty row which was created by extending count. Row Height - Sets height of the rows. Header Type - Sets features of the rows in the chart.
ITEM NO Gives a specific number to Instrument Item.
STRING - Means the general letters, and is used in a text column in the chart.
NUMBER - Used in a column that requires calculation such as weight.
Header - Sets column text to be displayed in the front row in the chart. Width - Sets width of the rows in the chart. Justification - Sets alignment of the rows as right alignment or left alignment, or center alignment. Table Name - Data table to be displayed in the chart. Column Name - Data column to be displayed in the chart.
Main Equipment Chart Maximum Row - Specifies the maximum number of the rows in the chart. If the displayed number is larger than the maximum, it will be repeatedly displayed on the left of the chart. Header Count - Specifies the number of the rows in the chart. The user must set undefined categories as ‘none’ because the drawing can occur an error if the user creates a drawing with the empty row which was created by extending count. Row Height - Sets height of the rows. Header Type - Sets features of the rows in the chart.
ITEM NO Gives a specific number to Instrument Item.
STRING - Means the general letters, and is used in a text column in the chart.
NUMBER - Used in a column that requires calculation such as weight.
Header - Sets column text to be displayed in the front row in the chart. Width - Sets width of the rows in the chart. Justification - Sets alignment of the rows as right alignment or left alignment, or center alignment. Table Name - Data table to be displayed in the chart.
112
Plant Design System (PDS) Ortho Draw User's Guide
Option Column Name - Data column to be displayed in the chart.
Support Chart Support Chart allows the user to combine two different supports made in FrameWorks+ and Pelican Forge, and generate it. Header Type - Sets features of the rows in the chart.
QUANTITY - If it is set as ‘QUANTITY’, grouping order, table name, and column name are changed to ‘Disabled’. ,Then, quantity will be automatically calculated and will be displayed in the chart.
STRING - It means the general letters, and it is used in a text column in the chart.
NUMBER - It is used in a column that requires calculation such as weight.
Grouping Order - Sets the priority order for grouping. To refer to further information, see Instrument Chart.
Electrical Option Sets text, mark, chart, and drawing setting and elevation which are need to create a dimension electrical drawing. It can be set through Main > Option > Electrical menu, or by clicking
in the toolbar.
Range Set range of tray size to indicate dimension and label in electrical drawing.
Elevation See Piping Option (on page 59).
Condition Seat, Support Model Rule - See HVAC Option (on page 93). Structure Model Rule - See Piping Option (on page 59). Tray Model Rule - It is a setting for tray model. The setting rule is same as other model rules. Tray Tag Rule - Among the values brought to the tray tag set in Label Definition, select data to be displayed as tray label. The criteria is applied as the model rule is applied. MCT Tag Rule - Among the values brought to the MCT tag set in Label Definition, select data to be displayed as MCT label. The criteria is applied as the model rule is applied. Equipment Model Rule - See Piping Option (on page 59).
Plant Design System (PDS) Ortho Draw User's Guide
113
Option
Label Label Definition - Sets table and column of the data table to be displayed in electrical drawing as label or tag. (except Structure Column and Support No.) The user can select the data base table and the column used in PDS to change the label. If a wrong value is entered, empty data value will be shown, otherwise no drawing will not be created. Thus, the user must know an appropriate value for each table and column before entering the value.
Tray Tag - Sets Tag data to be used for Tray Label. For Tray Label, the combination of Tag, Size, and Elevation will be applied. In the Raceway models in PDS, you have to place a "drop point" and input tag to one line vertex and this information should have been loaded to EE schema, in order to represent complete tray tag on PD_Ortho generated electrical drawing. MCT Tag - Sets tag data to be used in MCT Label. The combination of tag, size, and elevation will be applied in MCT Label. Other options are same as Pipe Option or HVAC Option.
114
Plant Design System (PDS) Ortho Draw User's Guide
Option Label Format
Criteria - It is an option to exclude a graphic image from Label or Tag, displaying only graphics without labeling or tagging. (ex. If the user choose *pipe*, label or tag will be created regardless of the letters before or behind it. ‘*’ : It does not figure regardless of the number. ‘?’ : It does not figure the letters identical to the number. ‘!’ : It figures the conditions inversely. Delimiter - The letters defined as delimiter are deleted when generate it, and the letters are applied in order. Order - Selects one among the sentences categorized by delimiter. If no value was entered, delimiter will work as CR/LF(Carriage Return and Line Feed). Omission - A symbol to indicate the start point and the end point of the part to be omitted in Tag or Label must exist as a pair. If it is not a pair, it should not be applied. Prefix - Sets Prefix to be displayed before Label or Tag. Suffix - Sets Suffix to be displayed next to Label or Tag.
Plant Design System (PDS) Ortho Draw User's Guide
115
Option Label Expression Defines a form of the label.
Tray Label, MCT Label - Tray label and MCT label are consisted of tag, size, and elevation. It is displayed in three steps, and the user can set contents to be displayed in each step. Equipment Label - The user can set main equipment label and reference equipment label, and can choose one line or two line. The user can choose two out of Equipment No, Elevation, and Description, and can put user string in between. The user can choose one of Internal Fixed Line, External Fixed Line, and Helix as main equipment label type
Symbology Sets symbology to be used in electrical drawing. The user can set Level, Color, Weight, Font, and Width, Line Style, Style and Style Clearance, and Lead Line From.
116
Plant Design System (PDS) Ortho Draw User's Guide
Option Level, Color, Weight, Font are same as used in MicroStation.
See Piping Option (on page 59) to refer to specification.
Location Aligns the charts to be used for the drawing.
Plant Design System (PDS) Ortho Draw User's Guide
117
Option Position criteria must be located on the top right of the chart.
Dimension External Dimension - Tray Dimension is basically displayed in four steps such as Overall Dimension, Structure Grid Dimension, Structure / Equipment Dimension, and Tray Dimension.
118
Plant Design System (PDS) Ortho Draw User's Guide
Option If the checkbox on the right is checked, dimension will be displayed. If not, dimension will not be shown. If it is not checked, the selected dimension layer will be disappeared. It is the value from (A) to (Q), the interval between one and another can be adjusted as shown.
Plant Design System (PDS) Ortho Draw User's Guide
119
Option Internal Dimension
Internal Dimension Criteria - The user can select Column or Beam, or Equipment as a standard of Internal Dimension. Internal Dimension Object - The user can select Component or Support, or Tray Vertex as an object to generate Internal Dimension Internal Label Offset - Set distance between Internal Label text and line.
120
Plant Design System (PDS) Ortho Draw User's Guide
Option
Symbol Other Symbol
Symbol Name - Inputs cell name of the cell library to be used for the drawing. Scale - Sets size to be displayed on the drawing.
Plant Design System (PDS) Ortho Draw User's Guide
121
Option Ref. Equipment Symbol - Sets symbol to be displayed in Reference Equipment.
Criteria - It is a function to choose an item in the Ref. equipment that the symbol mark will be applied. Apply the symbol after matching the data value that was set in Label Definition with the value entered in the Ref. Equipment Symbol Criteria. It does not match the whole data, but compares the numbers of the letters entered in the Ref. Equipment Symbol Criteria. For example, if the user enters ‘S-001’ in the Ref. Equipment Symbol Criteria and there are three types of data value such as ‘S-0012’, ‘S-0022’, and ‘SP-001’, the item ‘LIGHT’ Symbol will be applied is ‘S-0012’. Finally, the item applied to the criteria is not applied to the next criteria. Symbol Name - Sets a symbol mark to be used for the Ref. Equipment as the Ref. Equipment Symbol Criteria. Description - Enters description to generate the Ref. Equipment chart. Scale - Sets size of the symbol mark to be displayed on the drawing.
122
Plant Design System (PDS) Ortho Draw User's Guide
Option Support Symbol
Criteria - It is a function to choose an item in Support that symbol mark will be applied. Apply the symbol after matching the data value extracted from Label Definition with the value entered in Support Symbol Criteria. However, Prefix set through Label Format is not applied, and capital letters are distinguished from small letters. It does not match the whole data, but compares the numbers of the letters entered in Support Symbol Criteria. For example, if the user inputs ‘SP1’, ‘SP2’, and ‘SP3’ in Support Symbol Criteria and there are three types of data values such as ‘SP12’, ‘SP22’, and ‘SP30’, the item ‘SUPP1’ symbol mark will be applied is ‘SP12 while the item that ‘SUPP2’ Symbol Mark will be applied, is ‘SP22’ as ‘SUPP3’ to ‘SP30’. Lastly, the item that was applied to the criteria, should not be applied to the next criteria. Symbol Name - Set the symbol mark to be used in Support as Support Symbol Criteria. Scale - Sets the size of the symbol mark to be displayed on the screen.
Plant Design System (PDS) Ortho Draw User's Guide
123
Option Instrument Item Symbol
124
Plant Design System (PDS) Ortho Draw User's Guide
Option
Chart Tray BOM Chart - Sets the Tray BOM (Bill of Material) Chart.
Header Type - Sets features of the rows in the Chart. ITEM NO - Indicates the number of a row. If the user selects ‘ITEM NO’, Group Order, Tables will be locked. STRING - Means general letters, and it is used in text column in the chart. NUMBER - It is set in the column with the same number as weight, and the number will be calculated by group and will be displayed in the chart. QUANTITY - If it is set as ‘QUANTITY’, Grouping Order, Table Name, and Column Name will be changed to ‘Disabled’. And the quantity will be automatically calculated and will be displayed in the chart. Header Text - Set text to be displayed on the first row of the chart. Grouping Order - Set the priority order for grouping. Width - Set a width of each row in the chart. Justification - Set alignment of the rows as left or right, or center alignment. Straight Table - Set column of the straight table to be displayed in the chart.
Plant Design System (PDS) Ortho Draw User's Guide
125
Option Fitting Table - Set column of the fitting table to be displayed in the chart. Support Chart - See HVAC Option (on page 93). Ref. Equipment Chart - See Piping Option (on page 59).
See Also Option (on page 45)
Structure Grid Data Option It can be set by using Main > Option > Structure Grid Data menu or by clicking toolbar.
in the
Area Name - It is the grid group name to be applied to the drawing. Set Structure Column as Grid Text in Label Definition, and select an appropriate name among the area names which were set in General Information > View Information > Structure Grid Area. Grid No. - Structure Column Text to be displayed on the drawing. Start Point, End Point - Sets coordinates X, Y of the start point and the end point of the grid.
See Also Option (on page 45)
126
Plant Design System (PDS) Ortho Draw User's Guide
SECTION 7
Report This section describes Report function of PDS Ortho Draw.
In This Section Report On/Off ................................................................................ 127 Pipe Line ........................................................................................ 129 Piping Support ............................................................................... 130 Piping Instrument Item .................................................................. 131 Piping Special Item ........................................................................ 132 Equipment ...................................................................................... 133 Equipment Nozzle ......................................................................... 134
Report On/Off There is a checkbox to on/off drawing report in bottom right of Generation Setting in Discipline.
Plant Design System (PDS) Ortho Draw User's Guide
127
Report A report file is created by drawing, and the storing path is set in Environment Setting.
Report supports six forms such as Pipe Line, Piping Support, Piping Instrument Item, and Piping Special Item, Equipment, and Equipment Nozzle and it is be opened in Excel due to the CSV form. Reports are created when the label in the same category is on.
See Also Report (on page 127)
128
Plant Design System (PDS) Ortho Draw User's Guide
Report
Pipe Line Align Pipe Line Label based on the Line Id and the Line Label. It shows diameter and model No. with View No.
See Also Report (on page 127)
Plant Design System (PDS) Ortho Draw User's Guide
129
Report
Piping Support Align Piping Support based on the Support No.. It shows diameter, Line No., Coordinates and Model No., D/B Table Name, and View No.
See Also Report (on page 127)
130
Plant Design System (PDS) Ortho Draw User's Guide
Report
Piping Instrument Item
Align Piping Instrument Item based on the Tag No. It shows diameter, line No., coordinates and model No., D/B Table Name, and view No.
See Also Report (on page 127)
Plant Design System (PDS) Ortho Draw User's Guide
131
Report
Piping Special Item Align Piping Special Item based on the Tag No. It shows diameter, line No., coordinates and model No., D/B Table Name, and view No.
See Also Report (on page 127)
132
Plant Design System (PDS) Ortho Draw User's Guide
Report
Equipment Align Equipment based on the Equipment No. It shows description_1, description_2, TDF, insulation Thk, coordinates and model No., DB Table Name, and view No.
See Also Report (on page 127)
Plant Design System (PDS) Ortho Draw User's Guide
133
Report
Equipment Nozzle Align Nozzle based on the Equipment No. an d the Nozzle No. Then it will display diameter, Std. rating, end preparation, coordinates, orientation, center to face and model No., D/B table name, view no.
See Also Report (on page 127)
134
Plant Design System (PDS) Ortho Draw User's Guide
SECTION 8
Editor This Chapter describes Editor that the user can edit the created drawing in PDS Ortho Draw.
PDS Ortho Draw Editor
Process View Drawing out of the drawing directory created by PDS Ortho Draw, to start PDS Ortho Draw Editor on the drawing.. The displayed Editor is consisted of ten buttons as shown. PD_ORTHO Smart Tag Edit - Moves tag, label, and internal dimension which were created in PDS Ortho Draw.
Plant Design System (PDS) Ortho Draw User's Guide
135
Editor It is different from Move because it does not move the point that the lead line points.
PD_ORTHO Change Direction - Moves a tag and label from a horizontal orientation to a vertical orientation. Place Fence Block - Set Fence Block on the drawing. Fence Stretch - Move the internal drawing of the Fence Block. The external lines connected are extended. PD_ORTHO Axis Lock - On/Off Axis Lock. If it is on, it can be moved only from up to down, or from left to right. PD_ORTHO Group Lock - On/Off Graphic Group Lock. If it is on, it is applied to the same graphic group when using Edit function such as Move, Copy, Rotate, and Scale. PD_ORTHO Reference file View - Opens the directory window of reference files. Move - Moves the selected element. Unlike in Smart Tag, Lead Line Point can also be moved.
136
Plant Design System (PDS) Ortho Draw User's Guide
Editor Copy - Copies the selected element. PD_ORTHO Rotate - Rotate the selected element at the angle set by the user. PD_ORTHO Scale - Sets scale of the selected element. Text Edit - Edits the selected text element. Extend Element - Extends Line Element. PD_ORTHO Dimension Align - Align Dimension. Click on the button, and select dimension to be the standard of alignment. If the user selects vertical dimension, the standard dimension should be vertical dimension while the user selects horizontal dimension, the standard should be horizontal dimension. Click once more to identify it after selecting the standard dimension. After selecting dimension to be aligned, click again to move the selected dimension. The user can click Dimension Align Initialize button to select an another dimension to be the standard. If it is used as Smart Tag Edit, it can be efficiently edited.
PD_ORTHO Dimension Align Initialize - Initializes Dimension Align, and sets the standard dimension. Undo - Cancels the last operation. MicroStation Exit - Exits MicroStation.
Plant Design System (PDS) Ortho Draw User's Guide
137
Editor
138
Plant Design System (PDS) Ortho Draw User's Guide
Index C Chart Tab (Common Options Dialog Box) • 57 Chart Tab (HVAC Option Dialog Box) • 112 Chart Tab (Piping Option Dialog Box) • 88 Common Option • 45 Condition Tab (HVAC Option Dialog Box) • 95 Condition Tab (Piping Option Dialog Box) • 62
D Dimension Tab (Common Options Dialog Box) • 54 Dimension Tab (HVAC Option Dialog Box) • 108 Dimension Tab (Piping Option Dialog Box) • 82 Discipline Setting • 30 Drawing • 43 Drawing General Information • 14 Drawing Type Setting • 31 Drawing Update Dialog Box • 13 Drawing View • 22
Generation Setting - HVAC • 38 Generation Setting - Piping • 36
H HVAC Option • 93
I Installation • 3
L Label Tab (HVAC Option Dialog Box) • 100 Label Tab (Piping Option Dialog Box) • 69 Location Tab (Common Options Dialog Box) • 53 Location Tab (HVAC Option Dialog Box) • 107 Location Tab (Piping Option Dialog Box) • 81
M Main Menu • 12 Match Line Data • 18 Misc Tab (Common Options Dialog Box) • 58
E
O
Editor • 135 Electrical Option • 113 Elevation Tab (HVAC Option Dialog Box) • 93 Elevation Tab (Piping Option Dialog Box) • 61 Environment • 26 Equipment • 133 Equipment Nozzle • 134
Option • 20, 45 Option Profile Manager • 33 Overview • 9
G Generate Drawing • 21 Generation Drawing • 43 Generation Setting • 19, 34 Generation Setting - Common • 36 Generation Setting - Electrical • 40
Plant Design System (PDS) Ortho Draw User's Guide
P PCS Monument Tab (Common Options Dialog Box) • 47 PDS Model Setting • 28 PDS Ortho Draw Environment Variables • 6 PDS Ortho Draw Initial Setup • 7 PDS Ortho Draw Installation • 4 PDS Ortho Draw Login Dialog Box • 11 PDS Ortho Draw Overview • 1 PDS Ortho Draw System Requirements • 3 Pipe Line • 129 Piping Diameter Table • 32
139
Index Piping Instrument Item • 131 Piping Option • 59 Piping Special Item • 132 Piping Support • 130 Preface PDS • iii
R Range Tab (Piping Option Dialog Box) • 60 Report • 127 Report On/Off • 127 Report Tab (Piping Option Dialog Box) • 91
S Settings • 25 Structure Grid Data Option • 126 Symbol Tab (Common Options Dialog Box) • 55 Symbol Tab (HVAC Option Dialog Box) • 110 Symbol Tab (Piping Option Dialog Box) • 84 Symbology Tab (Common Options Dialog Box) • 49 Symbology Tab (HVAC Option Dialog Box) • 103 Symbology Tab (Piping Option Dialog Box) • 75
U Unit Tab (Common Options Dialog Box) • 47 Update Drawing • 44 User Account • 34
V View Drawing • 44 View General Information • 17
140
Plant Design System (PDS) Ortho Draw User's Guide
View more...
Comments