P442 Cortec
Short Description
p442...
Description
Our policy is one of continuous development. Accordingly the design of our products may change at any time. Whilst every effort is made to produce up to date literature, this document should only be regarded as a guide and is intended for information purposes only. Its contents do not constitute an offer for sale or advice on the application of any product referred to in it. We cannot be held responsible for any reliance on any decisions taken on its contents w ithout specific advice.
CORTEC
Ordering information
Distance Protection P442 Nominal auxiliary voltage 24 - 48 Vdc 48 - 110 Vdc (40 - 100 Vac) 110 - 250 Vdc (100 - 240 Vac)
Variants Order No. **
P44 2 1 2 3
In/Vn rating Dual rated CT (1 & 5A : 100 - 120V) Module Sum (∑1A / PXDB)
1 5
IEC 61850-9-2LE Sampled Analogue Values Ethernet board (Not yet available)
A
Hardware options Standard version IRIG-B Only (Modulated) Fibre optic converter (Courier, Modbus,IEC60870-5-103 or DNP3) (Note: converts RS485 port to fibre optic; NOT extra port )
1 2 3
IRIG-B input and Fibre optic converter (Courier, Modbus,IEC60870-5-103 or DNP3) (Note: converts RS485 port to fibre optic; NOT extra port )
4
Single Ethernet 100Mbit/s Second Rear Comms + InterMiCOM IRIG-B (Modulated) + Second Rear Comms + InterMiCOM Single Ethernet (100Mbit/s) plus IRIG-B (Modulated) Software version '31' and later (Suffix J) Single Ethernet (100Mbit/s) plus IRIG-B (De-modulated) Software version '31' and later (Suffix J) IRIG-B (De-modulated) Software version '31' and later (Suffix J) InterMiCOM + Courier Rear Port * InterMiCOM + Courier Rear Port + IRIG-B modulated * Redundant Ethernet Self-Healing Ring, 2 multi-mode fibre ports + Modulated IRIG-B Redundant Ethernet Self-Healing Ring, 2 multi-mode fibre ports + Un-modulated IRIG-B Redundant Ethernet RSTP, 2 multi-mode fibre ports + Modulated IRIG-B Redundant Ethernet RSTP, 2 multi-mode fibre ports + Un-modulated IRIG-B Redundant Ethernet Dual-Homing Star, 2 multi-mode fibre ports + Modulated IRIG-B Redundant Ethernet Dual-Homing Star, 2 multi-mode fibre ports + Un-modulated IRIG-B * NB: Options av ailable with Software version 45 (Design Suffix K) Software options 16 Logic Inputs & 21 Relay Outputs without check synchronising 16 Logic Inputs & 21 Relay Outputs with check synchronising 16 Logic Inputs & 18 Relay Outputs (4 High Break) with check synchronising * 16 Logic Inputs & 21 Relay outputs (3 Fast Trip) with check synchronising 16 Logic Inputs & 21 Relay outputs (6 Fast Trip) with check synchronising * NB: Option C is only available with Design Suffix K & Software version 40 or later
A B C D E
Protocol options K-Bus Modbus VDEW (IEC 60870-5-103) DNP3.0 UCA2 + Courier via rear RS485 port (Ethernet hardware options [i.e. 6] only) IEC61850 + Courier via rear RS485 port IEC61850 + IEC60870-5-103 via rear RS485 port DNP3 over Ethernet with Courier rear port K-Bus/RS485 protocol * NB: UCA2 option is not av ailable with Chinese HMI & Software version 30/31 (Design Suffix J) Mounting Flush Panel Mounting, Flush Panel Mounting, with harsh environment coating
6 7 8 A B C E F G H J K L M
1 2 3 4 5 6 7 8
M P
Language English, French, German, Spanish English, French, German, Italian
0 4
Chinese, English or French v ia HMI, with English or French only via Communications port
C
Software version Date and application dependant
**
Customer specific options Standard version Customer engineered version: ENEL Customer engineered version: TERNA Customer engineered version: RTE Customer engineered version: general
0 1 2 4 A
Hardware version Model and hardware version dependant
Page 2
*
151863849.xls.ms_office
6/14/2013
151863849.xls.ms_office
1 -4
5
6
7
8
9
10
11
12-13
14 15
P442 3 1 6 B 6 M 0 55 0 K
Distance Protection Relay Vx auxiliary rating
3 In/Vn rating
1 Hardware options
6
Version Software Options
B Protocol options
6 Mounting
M Language
0 Software version
55
Default Options available are derived from the last version available with the specified hardware version ( i.e. using this date -------------->)
6/14/2013
Customer Specific Options
0 Hardware version
K
Model and hardware version dependant
Page 3
151863849.xls.ms_office
6/14/2013
P44P442316B6M0550K External Connection Diagram External Connection Diagram: Comms options Outline Diagram
MASTER : 10P44201 : 10Px4001-1 : GN0040 ROUTING
Test Instruction
: Z7Px40
A Original created from composite P441-2-3-4 - 09/09/04
Master Text
P442316B6M0550K Distance Protection Relay Vx auxiliary rating : 110 - 250 Vdc (100 - 240 Vac) In/Vn rating : Dual rated CT (1 & 5A : 100 - 120V) Hardware options : Single Ethernet 100MBit/s Software options : 1 & 3 Pole tripping/reclosing with 16 inputs & 21 outputs. With check synchronising Protocol options : IEC61850 + Courier via rear RS485 port Mounting : Flush Panel Mounting, Language : English, French, German, Spanish Software version : 55 Customer Specific Options : Standard version
Version :
A B C
Original created from composite P441-2-3-4 - 09/09/04 EXCLUDES Customised Versions for ENEL and T ERNA Issue "300J" released with DC date of 07/01/05 as per CDN R5283 - 20/11/04 ZN0020002 removed from BOM as this is now a fixed item on the final assembly GN0287 as per CDN R5290 D 23/11/04 E Relationships between hardware and protocol options corrected (specificall y IRIG-B) - 09/12/04 F Rules modified on quantities of GN2037001 & ZB4018215 - 07/01/05 G Ethernet Licences added to BOM - 14/01/05 Software version "200G" removed from cortec as CDN R5162 held production due to technical defect and was the H fix was to release new software "300G" via CDN R5178 - 28/1/05 Corrections to quantity of ZN0031002 (was always1 for Fast Tri p) & of ZN0031001 (was always zero for Fast Trip) J - 22/08/05 K Protocol Option dependency on Hardware changed effective 27/08/2004 (Software version "30") - 01/09/05 L Quantity of ZN0031001 for model 'D' and Design Suffix 'G' corrected to 2 - 06/01/05 M N O P Q R S T U V W X Y Z AA AB AC AD AE AF
References to NCIT also read "IEC 60044-8", "+ InterMiCOM" added to Second Rear Comms options - 06/01/05 Chinese language option added - 19/04/06 NCIT option released per F LHOMME's e-mail of 20/04/06 - 20/04/06 Chinese HMI option offer restricted to exclude UCA2/Ethernet per P Li ng's e-mail of ??/??/?? - 07/06/06 "Customised to order" with digit #14="A" added 11/07/06 "31" Software options added - includes IEC61850, no high break options; ENEL, TERNA & RTE customer specific options added; NCIT Option withdrawn (see CID SBIA-6WQDEZ) - 02/01/07 S module made available: product released by CID DFRO-6XSDSZ; selection of previous versions of software/hardware enabled - 30/01/07 Ethernet was showing availablity for earlier variants in error - 21/02/07 VDEW protocol option withdrawn retrospectively for Phase 1 relays with rear comms as per Denis Froment's email of 19/03/07 - 20/03/07 BOM and Date Drivers retrospectively corrected to select either GN0175001 with GN0006 or GN0287001with GN0179 - 12/04/07 Software version '35' released by CID DFRO-73UL5S - 08/06/2007 Design Suffix 'K' version rel eased: CID DFRO-74HMG6 - 12/07/2007 Lookup error corrected on model number software digits - 02/08/2007 Jumper positions corrected on ZN0031002 for Models 'D' & 'E', Design Suffix 'K' - 30/11/2007 Software version '36' released by CID DFRO-7CVCWG - 28/03/08 DNP3.0 protocol released for software version '36' by CID DFRO-7F4KWX - 13/06/2008 BOM rules corrected on Input Modules for design suffix 'B' & 'C' - 17/09/08 Lookup error corrected on Master Text Software options - 29/10/2008 '45' Software released by CID DFRO-7LKKGJ, includes DNP3.0 over ethernet protocol & InterMiCOM comms options - 05/12/2008 Improvement to Master Text l ookup for product options - 06/05/2009
AG
Redundant Ethernet options added; software version '50' added; Vx rati ng changed in line with CID BLIN-7P7HJX AH Redundant Ethernet options made available, see CIDs DFRO-7YADXM & SKEL-7YBM34- 04/12/2009 AI BOM rules corrected for final assys on Suffix 'B', 'C' & 'G' - 12/01/10 AJ BOM rules corrected Hardware options 'E' & 'F' - 02/02/2010 Restrictions to protocol options for software version 2.8/'304J' for RTE released on CID SBIA-6RGCAQ applied AK retrospectively 25/03/2010 AL '55' software released by CID DFRO-895BJK - 21/09/2010 AM References to Alstom, Areva and MiCOM removed - 5/10/10 AN Release of Harsh Environment coating option -see CID RPRI-8CYG5J - 17/01/2011 AO Software version re-added to Master Text - 03/02/2011 AP Software versions availability set as per SCAR-8H2EGP '09', '35' & '40' withdrawn - 01/06/2011 AQ Software version '60' released by CID DFRO-8JQG32 - 01/08/2011 AR Software version '35' Reinstated by CID DFRO-8KNKFL, K-Bus only - 22/08/2011 AS Date formulas updated for withdrawn software versions - 12/12/2011
Page 5
151863849.xls.ms_office
6/14/2013
BOM
PCS MATERIAL MASTER P442316B6M0550K
Material GN0431001 ZN0021003 ZN0031001 ZN0049001 GN0277001 GN0010074 GN2037001 ZB9800801 ZB9800802 ZB4018110 ZB4018215
Page 6 of 6
Description Common parts Power supply (110 - 250V dc) Relay output PCB Px40 100Mhz Ethernet Bd F/ASSY USER INTERFACE 60TE PHASE 2 Assembly Std. Input Module (110V ac) Blanking plate License f or VxW orks Sisco License for MMS-Ease Lite Self-tapping Screw No 4 Self-tapping Screw No 6
151863849.xls.ms_office6/14/2013
Qty. Required 1 1 3 1 1 1 1 1 1 10 2
Position / Reference
Ref 1 Ref 2, Slots 2, 3, 4 Ref 6 Ref 22 Ref 23 Ref 34 Ref 55 Ref 56 Ref 60 Ref 61
Unit EA EA EA EA EA EA EA EA EA EA EA
View more...
Comments