Lux  MACHINE ABOVE - 2,50 m/s BUILDER’S WORK CATALOGUE FAA29100H_BWC

07-04-15

Version: a-e

800 kg – 1600 kg

   d   e   v   r   e   s   e   r   s    t    h   g    i   r    l    l    A  ,    7    0    0    2   y   n   a   p   m   o    C   r   o    t   a   v   e    l    E   s    i    t    O    ©

BUILDER'S WORK CATALOGUE Lux 

2/38

MAIN

FAA29100H_BWC

Version : a-e

Date: 07-04-15

This catalogue summarizes useful information for installation of the Otis Gen2 TM Machine above 2,5m/s 800 kg–1600 kg range in buildings.

The catalogue is divided into three main parts:

Part 1: General information The first part contains general information about the building interfaces that must be complied with in order to obtain a good final product.

Part 2: Builder’s work drawing (single car) The second part contains a definition of the builder’s work drawings for the Gen2 Machine above 2,5m/s 800 kg–1600 kg range with: - The building interfaces and dimensions for a single lift in the hoistway (doors are installed in the hoistway) - The mechanical reactions exerted by the lift on the building for a single lift in the hoistway.

Part 3: Information concerning banks of lifts The third part contains information for installing the Gen2 800 kg–1600 kg range in banks. Bank Bank

Dupl Duplex ex

Trip Triple lex x

Number of lifts in the bank

2

3

Quad Quadru rupl plex ex Quin Quintu tupl plex ex 4

5

Sext Sextup uple lex x

Octo Octopl plex ex

6

8

BUILDER'S WORK CATALOGUE Lux 

2/38

MAIN

FAA29100H_BWC

Version : a-e

Date: 07-04-15

This catalogue summarizes useful information for installation of the Otis Gen2 TM Machine above 2,5m/s 800 kg–1600 kg range in buildings.

The catalogue is divided into three main parts:

Part 1: General information The first part contains general information about the building interfaces that must be complied with in order to obtain a good final product.

Part 2: Builder’s work drawing (single car) The second part contains a definition of the builder’s work drawings for the Gen2 Machine above 2,5m/s 800 kg–1600 kg range with: - The building interfaces and dimensions for a single lift in the hoistway (doors are installed in the hoistway) - The mechanical reactions exerted by the lift on the building for a single lift in the hoistway.

Part 3: Information concerning banks of lifts The third part contains information for installing the Gen2 800 kg–1600 kg range in banks. Bank Bank

Dupl Duplex ex

Trip Triple lex x

Number of lifts in the bank

2

3

Quad Quadru rupl plex ex Quin Quintu tupl plex ex 4

5

Sext Sextup uple lex x

Octo Octopl plex ex

6

8

BUILDER'S WORK CATALOGUE Lux  FAA29100H_BWC

1



3/38

INDEX Version : a-e

Date: 07-04-15

PART 1: GENERAL INFORMATION

4

1.1.

DEFINITIONS

4

1.2.

DIMENSIONS

5

1.3.

REQUIREMENTS REQUIREMENTS FOR THE WELL – GENERAL WELL TOLERANCES

8

1.4.

ELECTRICAL POWER SUPPLY AND TELEPHONE LINE

15

1.5.

HEAT DISSIPATION

17

1.6.

MAIN BUILDING LIMITATIONS

17

PART 2: EFFORTS ON THE HOISTWAY WALLS

18 

LIST OF THE COMPONENTS EXERTING EFFORT ON THE WALL AND ON CEILING

18

2.2.

20

2.1.

3

GENERAL VIEW

PART 3: INFORMATION CONCERNING BANKS OF LIFTS

25 

3.1.

REQUIREMENTS REQUIREMENTS CONCERNING BANKS OF LIFTS

25

3.2.

RECOMMENDED RECOMMENDED HOISTWAY DIMENSIONS (ELEVATION)

38

3.3.

HOOKS AND REACTION THE PIT

38

3.4.

LOCATION OF THE HOISTWAY FIXTURES FI XTURES

38

BUILDER'S WORK CATALOGUE Lux 

PART 1: GENERAL INFORMATION

FAA29100H_BWC

1

4/38

Version : a-e

Date: 07-04-15

PART 1: GENERAL INFORMATION

1.1.

DEFINITIONS CONCEPT This range of lifts is designed with machine room above the well , one entrance car with center door opening (CLD) , and rear counterweight .

BUILDING DIMENSIONS  All dimensions used in this catalogue are commercial dimensions. SYMBOLS The symbols used in this catalogue are the following: Identifier

Definition

CD

Car internal depth (mm)

CH

Car internal height (mm)

CLD

Central landing door (Centre Opening)

CW

Car internal width (mm)

HD

Hoistway depth (mm) (including hoistway doors)

HW

Hoistway width (mm)

K

Overhead height (mm)

OP

Door opening width (mm)

OPH

Door opening height (mm)

R

Rise (m)

RW1

Left Return Wall (mm)

RW2

Right Return Wall (mm)

S

Pit depth (mm)

V

Rated Speed (m/s)

TLD TYFAC WTW

Telescopic Landing Door (Side Opening) Type of Façade Wall to wall (mm)

TYPE OF DOORS AND DOOR HAND Only one car entrance car with center opening doors is proposed Note: The door-opening axis is located in t he car axis. LANDING DOOR FACADES, DOOR FRAMES AND DOORS INSTALLATION SF: door panels only are visible. Return walls are compulsory ( SMALL FRAME ), NF: door panels only are visible. Return walls are compulsory ( NO FRAME ) Landing doors are installed in the hoistway or on the landing.

BUILDER'S WORK CATALOGUE Lux 

5/38

PART 1: GENERAL INFORMATION

FAA29100H_BWC

Version : a-e

Date: 07-04-15

CAR OPERATING PANEL (COP) LOCATION (CAR CONTROL PANEL) The main COP is located on the car right side panel when entering in the car by the entrance. The option with a second auxiliary COP at the car opposite side is available. HALL BUTTONS LOCATION In case of single lift, the hall buttons are mounted on the return walls adjacent to the landing doors. The minimum lateral distance between the centre line of the button and any corner of adjacent walls shall be 500 mm. 1.2. 1.2.1

DIMENSIONS CAR INTERNAL SIZES Nb of passenger

Stamped duty load (kg)

CW (mm)

CD (mm)

10

800

1350

1400

Door CLD 800 CLD 900 CLD 900

13

1000

1600

1400

CLD 1000 CLD 1100

1.2.2

17

1275

21

1600

2000

1400

CLD 1100

2000

1700

CLD 1100

2100

1600

CLD 1100

HOISTWAY DIMENSIONS (PLAN) (MAXIMUM, MINIMUM COMMERCIAL DIMENSIONS IN mm)

CAR WIDTH (CW) CW/2 1 3

CW/2 2 4

   D    C Hoistway Axis Door Opening and Car Axis

OP RW1

RW2 HW/2

HW/2

HOISTWAY WIDTH (HW)

FRONT ENTRANCE

   D    H    H    T    P    E    D    Y    A    W    T    S    I    O    H

BUILDER'S WORK CATALOGUE Lux 

PART 1: GENERAL INFORMATION

FAA29100H_BWC

1.2.3

6/38

Version : a-e

HOISTWAY-DIMENSIONS-PLAN 1ENTRANCE CAR

(COUNTERWEIGHT

Date: 07-04-15

WITHOUT

OR

WITH

SAFETIES

TYFAC : SF LIFT CAPACITY Load & Number of passenger

CAR INTERNAL SIZE Car Width

Car Depth

Rated Speed

CW (mm)

CD (mm)

V (m/s)

Door Opening OP (mm)

Rise

Hoistway Depth

HOISTWAY DIMENSIONS Hoistway Return Walls all landings Width

R (m)

HD (mm)

HW (mm)

RW1 (mm)

RW2 (mm)

R≤80

2010

1950

525

525

R>80

2060

2000

550

550

R≤80

2010

2050

525

525

R>80

2060

2100

550

550

R≤80

2010

2200

600

600

R>80

2060

2250

625

625

R≤80

2010

2200

550

550

R>80

2060

2250

575

575

R≤80

2010

2400

600

600

R>80

2060

2450

625

625

R≤80

2010

2550

675

675

R>80

2060

2600

700

700

R≤80

2310

2550

675

675

R>80

2360

2600

700

700

R≤80

2210

2650

725

725

R>80

2260

2700

750

750

800 800 kg 1350

1400

2.50

10 Pass. 900

900 1000 kg 1600

1400

2.50

1000

13 Pass. 1100 1275 kg 2000

1400

2.50

1100

17 Pass. 1600 kg 2000

1700

2.50

1100

21 Pass. 1600 kg 2100

1600

2.50

1100

21 Pass.

TYFAC : NF LIFT CAPACITY Load & Number of passenger

CAR INTERNAL SIZE Car Width

Car Depth

Rated Speed

CW (mm)

CD (mm)

V (m/s)

Door Opening OP (mm)

Rise

Hoistway Depth

HOISTWAY DIMENSIONS Hoistway Return Walls all landings Width

R (m)

HD (mm)

HW (mm)

RW1 (mm)

RW2 (mm)

R≤80

2010

1950

545

545

R>80

2060

2000

570

570

R≤80

2010

2050

545

545

R>80

2060

2100

570

570

R≤80

2010

2200

620

620

R>80

2060

2250

645

645

R≤80

2010

2200

570

570

R>80

2060

2250

595

595

R≤80

2010

2400

620

620

R>80

2060

2450

645

645

R≤80

2010

2550

695

695

R>80

2060

2600

720

720

R≤80

2310

2550

695

695

R>80

2360

2600

720

720

R≤80

2210

2650

745

745

R>80

2260

2700

770

770

800 800 kg 1350

1400

2.50

10 Pass. 900

900 1000 kg 1600

1400

2.50

1000

13 Pass. 1100 1275 kg 2000

1400

2.50

1100

17 Pass. 1600 kg 2000

1700

2.50

1100

21 Pass. 1600 kg 2100 21 Pass.

1600

2.50

1100

BUILDER'S WORK CATALOGUE Lux 

PART 1: GENERAL INFORMATION

FAA29100H_BWC

1.2.4

7/38

Version : a-e

Date: 07-04-15

HOISTWAY DIMENSIONS (ELEVATION) (MAXI, MINI, COMMERCIAL DIMENSIONS)

1.2.4.1 PIT DEPTH: S (mm) Speed (m/s)

Door type

2,50

Centre opening

Rise (m)

S mini (mm)

 90

2370

>90

2370

S maxi (mm) 2500

1.2.4.2 OVERHEAD HEIGHT : K (mm) Speed (m/s)

K mini (mm)

K maxi (mm)

2,50

CH + 2050*

10000

* For CH=2200 : K mini = CH+2150 1.2.4.3 AVAILABLE DOOR and CAR HEIGHTS Door opening Height OPH (mm)

1.2.5

Car height CH (mm)

2000

2200

2300

2400

-

2100

-

2300

2400

2500

2200

-

-

2400

2500

2300

-

-

-

2500

HOISTWAY DIMENSIONS: RISE - DISTANCE BETWEEN DOORS SILLS MAXIMUM RISE IN METERS Speed (m/s)

R Maxi (m)

2,50

150

MAXIMUM DISTANCE BETWEEN DOORS SILLS: FH IN METERS FH max: 11 m, limitation given by the CEN code if there is no means of evacuating the passengers. If more than 11 m is required, contact Otis. MINIMUM DISTANCE BETWEEN DOORS SILLS: FH MIN (IN MILLIMETERS)

Door opening height

FH min (mm)

2000

2470

2100

2570

2200

2670

2300

2770

BUILDER'S WORK CATALOGUE Lux 

PART 1: GENERAL INFORMATION

FAA29100H_BWC

1.3.

1.3.1

8/38

Version : a-e

Date: 07-04-15

REQUIREMENTS FOR THE WELL – GENERAL WELL TOLERANCES

HOISTWAY DEPTH AND WIDTH TOLERANCES HOISTWAY TOLERANCES FOR SIMPLEX R    80M Maximum out of plumb of each hoistway wall ± 25 mm

   5    2

   H    T    P    E    D    Y    A    W    T    S    I    O    H    I    X    A    M

   5    2

   5    2    H    T    P    E    D    Y    A    W    T    S    I    O    H    L    A    I    C    R    E    M    M    O    C

   H    T    P    E    D    Y    A    W    T    S    I    O    H    I    N    I    M

   5    2

MINI HOISTWAY WIDTH 25

25 COMMERCIAL HOISTWAY WIDTH

25

25 MAXI HOISTWAY WIDTH

FRONT

OPENING

The actual hoistway walls are included between the two perfect vertical parallelepipeds Maximum out of plumb of each hoistway wall = 50 mm Commercial HW + 50    5  0   +    D    l   H   a    i   c   e  r   m   o  m   C Commercial HW - 50

   D    H    l    i  a   c   e  r   m   o  m   C

  0  -   5

25mm

25mm Commercial HW request to the builder 

 Actual location of the hoistway walls

Minimum authorized location for the wall

Maximum authorized location for the wall

Effective constructed wall

BUILDER'S WORK CATALOGUE Lux 

PART 1: GENERAL INFORMATION

FAA29100H_BWC

1.3.2

9/38

Version : a-e

Date: 07-04-15

HOISTWAY DEPTH AND WIDTH TOLERANCES HOISTWAY TOLERANCES FOR SIMPLEX R > 80M Maximum out of plumb of each hoistway wall ± 50 mm

   0    5

   H    T    P    E    D    Y    A    W    T    S    I    O    H    I    X    A    M

   0    5

   0    5    H    T    P    E    D    Y    A    W    T    S    I    O    H    L    A    I    C    R    E    M    M    O    C

   H    T    P    E    D    Y    A    W    T    S    I    O    H    I    N    I    M

   0 5

MINI HOISTWAY WIDTH 50

50 COMMERCIAL HOISTWAY WIDTH

50

50 MAXI HOISTWAY WIDTH

FRONT

OPENING

Maximum out of plumb of each hoistway wall = 100 mm The actual hoistway walls are included between the two perfect vertical parallelepipeds Commercial HW + 100   0   1  0   +    D    H    l    i  a   c   r   e   m   m   o   C Commercial HW - 100

  0  0  -  1    D    l   H   a    i   c   e  r   m   o  m   C

50mm

50mm Commercial HW request to the builder 

 Actual location of the hoistway walls

Minimum authorized location for the wall Maximum authorized location for the wall

Effective constructed wall

BUILDER'S WORK CATALOGUE Lux 

10/38

PART 1: GENERAL INFORMATION

FAA29100H_BWC

Version : a-e

Date: 07-04-15

The commercial dimensions HW; HD used to order the lift must be included between the maximum and minimum values (hoistway, commercial dimensions maximum, minimum : see part 2 ). The maximum out of plumb of each hoistway wall is ± 25 mm for rise R  80m and ± 50 mm for rise R> 80m Consequently, the equipment supplied is manufactured for installation in a well, the walls of which are inscribed in two perfect rectangular parallelepipeds defined in the sketches (dotted line : chapter 1-3-1 & 1-3-2 ). ELEVATION - TOLERANCES

-

-

1.3.3

Pit depth (s) tolerances The pit depth (maxi & mini values defined chapter 1.2.4.1) is determined with a building tolerance of + 20 mm. The effective pit depth given to Otis and included in these limits must be also with a tolerance of + 20 mm. Overhead dimension (K) tolerances The minimum overhead K defined in chapter 1.2.4.2 is determined with a building tolerance of – 20 mm. The effective overhead dimension (equal or above the minimum) is requested by Otis for the lift manufacturing (limit = 10000mm).

STRENGTH OF THE WALLS For the safe operation of the lift, the walls shall have a mechanical strength such that when a force of 300 N, being evenly distributed over an area of 5 cm² in round or square, section, is applied at right angles to the wall at any point on either face they shall: - Resist without permanent deformation, - Resist without elastic deformation greater than 15 mm. The mechanical reactions exerted by the lift on the building are given in the drawings part 2. The building walls thickness must be in accordance with the fire regulation.

1.3.4

STRENGTH ON THE PIT FLOOR The reactions on the pit floor are given in part 2. If accessible spaces do exist below the car or the counterweight, the base of the pit shall be designed for an imposed load of at least 5000 N/m² and: a) Either there shall be installed below the counterweight buffer, a solid pier extending down to solid grown or, b) The counterweight shall be equipped with safety gear. The lower part of the hoistway shall consist of a pit, the bottom of which shall be smooth and approximately level, except for any water drainage devices.  After the building-in of guide rail fixings, buffers, any grids, etc., the pit shall be impervious to infiltration of water. For a tanked pit, the builder shall provide a 150 mm thick material (concrete…) for fixing bolts and dowels.

BUILDER'S WORK CATALOGUE Lux 

PART 1: GENERAL INFORMATION

FAA29100H_BWC

1.3.5

11/38

Version : a-e

Date: 07-04-15

VENTILATION OF THE WELL AND THE MACHINE ROOM The hoistway and the machine room shall be suitable ventilated. It shall not be used to provide ventilation of rooms other than those belonging to the lift. Note: in the absence of relevant regulations or standards, it is recommended to provide ventilation openings at the top of the well, with a minimum area of 1% of the horizontal section of the well. The ambient temperature in hoistway and in the machine room shall be maintained between 0 °C and + 45 °C, taking into account the heat dissipated by the lift. See Para: Heat dissipation.

1.3.6

FLOOR USED FOR MATERIAL INTRODUCTION IN THE HOISTWAY In order to facilitate the handling of the lift material it is requested do not construct before material installation at the level determined for material introduction. Both the return walls will be constructed at this floor after the material installation inside the hoistway.

BUILDER'S WORK CATALOGUE Lux 

PART 1: GENERAL INFORMATION

FAA29100H_BWC

1.3.7

12/38

Version : a-e

Date: 07-04-15

BUILDING STRUCTURE Gen2 models can be installed in several types of buildings: - Concrete well, - Concrete beams and concrete slabs with bricks or block works wall, - Steel structure - Block works. List of the lift components with structural interfaces with the well : - Guide rail bracket - Landing door fixations - Hooks for handling the equipment.

CONCRETE WELL Minimum compression strength of 30 MPa is required for the concrete. Two fixation methods are available: - Steel anchorages: Otis installs the steel dowels after drilling of the concrete. - The constructor installs suitable rail inserts. The bolts are delivered and installed by Otis. Contact otis for precise definition. The maximum vertical distance between guide rails fixation is 3 m. CONCRETE BEAMS AND CONCRETE SLABS WITH BRICKS OR BLOCK WORKS WALL The structural Lift components interface on the concrete parts with the same requirements as for concrete walls. The maximum distance between slabs is 3 m. One additive concrete beam is required at the level of the highest guide rails fixations (see part 2). Consult Otis for detailed information. STEEL STRUCTURE The structural lift components are interfaced at the level of the floor beams with a maximum distance between beams of 3 m. Additive beams are required at the level of the highest guide rails (side walls). Consult Otis for detailed information. The natural frequency of the steel structure, which supported the lift, shall be above 5 Hz. The building beams on which the guide rails brackets are fixed shall have a maximum deflexion on 2 mm in the local area where the efforts are applied by the lift. Consult Otis for the value and the location of these efforts. BLOCK WORKS (Block works, cellular concrete, full body bricks) Specific anchorages (chemical dowels...) must be selected by the constructor and Otis, regarding the max load applied on interfaces components: (guide rails and landing doors). The maximum vertical distance between guide rails fixation is 3 m. Consult Otis for detailed information. See sketches in the following sheets.

BUILDER'S WORK CATALOGUE Lux 

PART 1: GENERAL INFORMATION

FAA29100H_BWC

1.3.8

13/38

Version : a-e

Date: 07-04-15

BUILDING STRUCTURE CONCRETE HOISTWAY Sketch 1 Hoistway roof level

Top of hoistway

CONCRETE BEAMS AND CONCRETE SLABS WITH BRICKS OR BLOCK WORKS WALL Sketch 2

Hoistway roof level

   0    0    4

   i   x   a    M    0    0    l    0   e    3   v   e    l   p   o    T

BUILDER'S WORK CATALOGUE Lux 

14/38

PART 1: GENERAL INFORMATION

FAA29100H_BWC

Version : a-e

Date: 07-04-15

STEEL DRY LINED BUILDING

Hoistway roof level

   0    0    4

   i   x   a   m    0    0    l    0   e    3   v   e    l   p   o    T

BLOCK WORKS Sketch 4 Hoistway roof level

Top of hoistway

BUILDER'S WORK CATALOGUE Lux 

PART 1: GENERAL INFORMATION

FAA29100H_BWC

1.4.

15/38

Version : a-e

Date: 07-04-15

ELECTRICAL POWER SUPPLY AND TELEPHONE LINE

1.4.1

ELECTRICAL CABLES INPUT Suitable electrical conduits shall be routed to the machine room for the following electrical functions: - Main power supply: 3 phases (see below 1.4.2) - Electrical supply for car lighting, hoistway lighting, alarm device and car and pit car and pit sockets (see below 1.4.3) - Telephone line (see below 1.4.4) - Other electrical options : car arrival hall light, car position contact, Intercommunication unit (car – porter lodge) (see below 1.4.5)

1.4.2

MAIN POWER SUPPLY (WITHOUT POWER SUPPLY FOR LIGHTING, SEE 1.4.3) For each lift, the power supply lines (3 phases + neutral + earth) shall be routed to the machine room. Definition in line with (IEC 364-4-63): IB = Useful current (current for which the circuit is designed) IZ = Continuous current-carrying capacity of the cable In = Nominal current of the protective device Operating characteristic of a device protecting a cable against overload shall satisfy, at least: IB In IZ

Table for electrical power supply (DATA NOT CONTRACTUAL)  All the following data are given for a 400 V AC power supply 40A/60A - Regenerative Drives are used .

Number of Passengers

Speed (m/s)

Starting Current IS (A)

Useful Current IB (A)

For information

Rated

Power

Line

Main

Copper cross

Calibration of

Power

Line

Section

Protection

S (kVA)

P (kW)

(mm  )

Device ( A )

10 (800kg )

2.50

32

26

18

18

10

50

13 (1000kg) 

2.50

37

31

21.5

21.5

10

50

17 (1275kg) 

2.50

38

31

21.5

21.5

10

50

21 (1600kg) 

2.50

47

39

37

37

10

50

 Additional information :  It is strongly recommended to separate neutral and protective conductor according to a TN-S system (5-wire net: 3 phases + neutral + earth).  Rated voltage available: 380 or 400 or 415 V, tolerance: + 10%.  Frequency: 50 or 60 Hz  If an earth leakage circuit breaker is used at the starting point of the power line, the required rating is 500 mA or more.  Copper cross section of the cable between building and controller in the machine room has to be calculated following the local code (i.e. IEC 364), considering the rated voltage, the currents determined with the here-above table and the external influences which can exist.

BUILDER'S WORK CATALOGUE Lux 

16/38

PART 1: GENERAL INFORMATION

FAA29100H_BWC

Version : a-e

Date: 07-04-15

Electrical supply for lighting and SOcket outlets (en81-1) For each lift, the power supply line for lighting (1 phase + neutral + earth) shall be routed to the machine room.  Rated voltage 220 or 230 or 240 V (tolerance + 10%)  Frequency 50 or 60 Hz  Single phase + neutral + earth 

This line shall be protected at the starting point according local code (IEC 364). RISE (meter))

Starting Current IS (A)

Useful Current IB (A

< 50

35

≥ 50

50

Machinery location Protection device for car and socket machinery

FUSE (A) for Lighting In Hoistway (LIH)

25

16 (∆: 10mA)

6 or 10

35

16 (∆: 10mA)

10 or 20

Note: This power supply for lighting could be connected to the main power line, on the supply side of the main switch. In this case the value of the current for the lighting must be added to the value of the current of the main power supply defined in the 1.4.2 In case of interruption of the normal lighting supply, there shall be an automatically rechargeable emergency supply which is capable of feading a lamp installed in the top of the hoistway (not supplied by Otis). 1.4.3

TELEPHONE LINE – EMERGENCY ALARM DEVICE For each Simplex or for each bank of lifts (Duplex, Triplex…), the telephone line shall be routed to the machine room of the first lift (Unit A see part 3). Provide 3 m of free cable from the machine room entrance with a RJ11 plug termination. Note: to comply with the EN81.1 chapter 14.2.3 (two-way voice communication allowing permanent contact with a rescue service), the basic device is the Otis REM ®  device connected to Otis through a public network.  Additional devices are available as options (one between all these 4 options): a) Car alarm button and wiring to the controller. Otis provides a normal open switch 2 A ; 50 VAC and the wiring to the controller. The customer alarm system can be connected to the controller; provide 3 m of free cable from the machine room entrance to each controller. b) Car alarm button and wiring to the pit Similar to a) but wiring to the pit of the lift instead to the controller. c) Car alarm button, wiring, alarm bell and battery (12 V DC)  All these components are delivered and installed by Otis in the well (no external interfaces). d) Intercommunication Unit Communication between the car and a porter lodge. Otis provides the wiring to the controller Provide 1 cable (2 wires 0,5 or 1 mm²) maxi length 200 m from the porter lodge to the first controller (3 m of free wiring from the machine room entrance).

1.4.4

OTHER ELECTRICAL OPTIONS - AHL2 (car arrival hall light). When the lift arrives to a floor, the floor corridor lighting shall come on automatically. For this purpose, Otis provides one contact per floor with the following characteristics: . maximum braking switch voltage : 250 V AC . maximum power rating 2000 VA (AC voltage). For each lift , the wiring for this function shall be routed to the bottom of the controller (10 m of free cable from the machine room entrance).

BUILDER'S WORK CATALOGUE Lux 

PART 1: GENERAL INFORMATION

FAA29100H_BWC

1.5.

17/38

Version : a-e

Date: 07-04-15

HEAT DISSIPATION Lift heat release in the machine room: Number of Passengers

10 13 17 21

1.6. 1.6.1

Speed (m/s)

Heat Release (kJ/s)

2.50

3,51

2.50

3,67

2.50

4,30

2.50

5,93

MAIN BUILDING LIMITATIONS GLASS HOISTWAY Only for totally enclosed well (hoistway) installed inside a building (e.g. atrium). The glass hoistway structure must comply with EN81.1 requirements (chapters 5.2.1.1 and 5.3.1).

1.6.2

HOISTWAY AND MACHINE ROOM ENVIRONMENT Environmental conditions:  AE1: presence of foreign solid bodies: negligible  AD1: presence of water: negligible  AG2: mechanical stresses: medium severity  According to IEC 60364 part 5 international standard - Electrical installation of buildings, low voltage electrical installation. Degree of protection: IP21: IP code according to EN 50 102 standard. IK = 5: IK code according to EN 60 529 standard.  Ambient temperature: The ambient temperature in the machine room is assumed to be maintained between 0 °C and + 45 °C.

1.6.3

SILLS FOR LANDING DOORS It is recommended to provide a slight counter slope in front of each landing sill to avoid water from washing, sprinkling, etc., draining into the well.

1.6.4

EARTHQUAKE Option: earthquake (Consult OTIS for detailed information)

1.6.5

FIREFIGHTERS LIFTS

In case of lift in conformance with the EN81-72 code the building must answer the following requirements. Refer to EN81-72 chapter 5-1-1; 5-1-4; 5-1-5; 5-1-6; 5-2-2; and 5-3-4. The maximum distance between floors is limited. Refer to EN81-72 chapter 5-4-7 and consult Otis to determine this limit for the contract.

BUILDER'S WORK CATALOGUE 18/38

Lux 

PART 3: INFORMATION CONCERNING BANKS OF LIFTS

FAA29100H_BWC

2

Version : a-e

Date: 07-04-15

PART 2: EFFORTS ON THE HOISTWAY WALLS Gen2 models can be installed in several types of hoistway structures: see sheet 12. In the sketches presented in the following sheets of this catalogue, the slabs and walls around lift wells are shown in blue color, whatever the building structure.

2.1.

LIST OF THE COMPONENTS EXERTING EFFORT ON THE WALL AND ON Hoistway width

 l  o w a l  W a l l t

ROOF OF THE MACHINERY

3

Hooks Location

ROOF OF THE HOISTWAY

  s   n   o    i   s   n   e   m    i    d    d   a   e    h   r   e   v    O

Holes

1

1

1

1 2

TOP LEVEL

FRONT

CEILING 

Guide rail bracket



Landing door fixation



Hooks for handling the equipment

ENTRANCE

BUILDER'S WORK CATALOGUE 19/38

Lux 

PART 3: INFORMATION CONCERNING BANKS OF LIFTS

FAA29100H_BWC

2.1.1

Version : a-e

Date: 07-04-15

HOISTWAY DEPTH - DOORS IN THE HOISTWAY (For doors installed on the landing: consult Otis) DIMENSIONS TABLE HOISTWAY DEPTH (HD) AND FRONT TO REAR WALL DIMENSIONS (WTW) WTW=HD

LIFT CAPACITY Load & Number of passenger

CAR INTERNAL SIZE Car Width

Car Depth

Door Opening

CW (mm)

CD (mm)

OP (mm)

800 800 kg 10 Pass.

1350

1400 900

900 1000 kg 13 Pass.

1600

1400

1000

1100 1275 kg 17 Pass. 1600 kg 21 Pass. 1600 kg 21 Pass.

2000

2000

2100

1400

1700

1600

1100

1100

1100

Rise

Wall to wall mini

HOISTWAY DIMENSIONS Wall to wall Hoistway maxi Depth mini

R (m)

WTW (mm)

WTW (mm)

HD (mm)

HD (mm)

R≤80

2010

2350

2010

2350

R>80

2060

2300

2060

2300

R≤80

2010

2350

2010

2350

R>80

2060

2300

2060

2300

R≤80

2010

2350

2010

2350

R>80

2060

2300

2060

2300

R≤80

2010

2350

2010

2350

R>80

2060

2300

2060

2300

R≤80

2010

2350

2010

2350

R>80

2060

2300

2060

2300

R≤80

2010

2350

2010

2350

R>80

2060

2300

2060

2300

R≤80

2310

2650

2310

2650

R>80

2360

2600

2360

2600

R≤80

2210

2550

2210

2550

R>80

2260

2500

2260

2500

Hoistway Depth maxi

BUILDER'S WORK CATALOGUE 20/38

Lux 

PART 3: INFORMATION CONCERNING BANKS OF LIFTS

FAA29100H_BWC

2.2. 2.2.1

Version : a-e

Date: 07-04-15

GENERAL VIEW MACHINE ROOM INTERFACE

P8

P2    1    M    I    D

1

P1   s    i   x   a   r   a    C

P7    D 2    H

Car axis

3

4 P3

P4 335

335

HW

ENTRANCE Number of passenger 10 pass.

13 pass.

17 pass.

21 pass. CW 2000 x CD 1700

21 pass. CW 2100 x CD 1600

DIM1 (mm)

863

863

863

1013

963

P1 (N)

21000

22500

29800

37000

37000

P2 (N)

23000

24000

31000

38000

38000

P3 (N)

23000

25500

33600

42000

42000

P4 (N)

23500

25500

33700

42500

42500

P7 (N)

2300

2300

2300

2300

2300

P8 (N)

2300

2300

2300

2300

2300

BUILDER'S WORK CATALOGUE 21/38

Lux 

PART 3: INFORMATION CONCERNING BANKS OF LIFTS

FAA29100H_BWC

2.2.2

Version : a-e

Date: 07-04-15

PIT INTERFACE

Car rail axis

HW 1

Number of passenger 10 pass.

13 pass.

17 pass.

21 pass.

P11 (N)

62000

68300

77000

84000

P12 (N)

100000

115000

138000

165000

P13 (N)

85000

94000

1110000

131000

P17 (N)

41000

46000

52000

58100

Simultaneous loads : P11 or P17 or P12 or P13

   D    H

BUILDER'S WORK CATALOGUE Lux 

22/38 PART 3: INFORMATION CONCERNING BANKS OF LIFTS

FAA29100H_BWC

2.2.3

Version : a-e

Date: 07-04-15

HOOKS – ( MACHINE ROOM ROOF )

CWT DBG/2+30

CWT DBG/2+30

CWT axis

T6 T5

T4 150

   5    3    1

Car DBG/2+90

   C    T    C

Car DBG/2+90

Car rail axis

T1

T2 T3

   0    2    2

HW1

HW2 HW

ENTRANCE

Rails hoisting and Car suspension Material distribution Rails hoisting and suspension Machine introduction and CWT suspension

Simultaneous loads on the hooks T1; T2; T6 SWL: Safe Working Load

Location

SWL (kN)

T1; T2 T3 T4; T5 T6

10 10 5 10

BUILDER'S WORK CATALOGUE 23/38

Lux 

PART 3: INFORMATION CONCERNING BANKS OF LIFTS

FAA29100H_BWC

2.2.4

Version : a-e

Date: 07-04-15

ALL LANDINGS TYFAC : SF

For RW1 and RW2 values see part 1 sheet 6 DOORS IN HOISTWAY

RW1

   0    2

   ±

RW2 OP + 100 ± 20

   0    5    +    H    P    O

100 for CLD

SILL "0" FINISHED FLOOR

   i   n    i   m    0    8

HW

WTW = HD

DOORS ON LANDING

RW1

   0    2

RW2

   ±

   0    0    2    7    ±   2    0    +    5    H    +    P    H    O    P    O

OP + 100 ± 20

100 for CLD

SILL "0" FINISHED FLOOR

   i   n    i   m    0    6 WTW

HD

HW

BUILDER'S WORK CATALOGUE 24/38

Lux 

PART 3: INFORMATION CONCERNING BANKS OF LIFTS

FAA29100H_BWC

2.2.5

Version : a-e

Date: 07-04-15

ALL LANDINGS For RW1 and RW2 values see part 1 sheet 6 DOORS IN HOISTWAY

TYFAC : NF

RW1

   0    2

   ±

RW2 OP + 60 ± 20

   0    5    +    H    P    O

100 for CLD

SILL "0" FINISHED FLOOR

   i   n    i   m    0    8

HW

WTW = HD

DOORS ON LANDING

RW1

   0    2

RW2

   ±

   0    0    2    7

   ±    2

OP + 60

   0    +    5    H    +    P    H    O    P    O

100 for CLD

SILL "0" FINISHED FLOOR

   i   n    i   m    0    6 WTW HD

HW

± 20

BUILDER'S WORK CATALOGUE 25/38

Lux 

PART 3: INFORMATION CONCERNING BANKS OF LIFTS

FAA29100H_BWC

3

Version : a-e

Date: 07-04-15

PART 3: INFORMATION CONCERNING BANKS OF LIFTS

3.1. 3.1.1

REQUIREMENTS CONCERNING BANKS OF LIFTS MAIN INFORMATION The Gen2 models 10 to 21 passengers are available in a bank of two to height lifts . Each lift is available with the same limitations as the single car lift. To be installed in a bank, all the lifts shall have the following parameters: Same speed. Same lift capacity (number of passengers and car size). Same number of floors, and location of entrances.

3.1.2

HOISTWAY LOCATION Lifts in bank can be installed in the same hoistway or in separated hoistway. For each lift, all simplex arrangements are available; use the information for single car (SIMPLEX).

3.1.3

PROTECTION IN THE HOISTWAY Where the hoistway contains several lifts an 1100 mm height top of car balustrade is installed.

3.1.4

ELECTRICAL POWER SUPPLY Use the information for single car (simplex).

BUILDER'S WORK CATALOGUE 26/38

Lux 

PART 3: INFORMATION CONCERNING BANKS OF LIFTS

FAA29100H_BWC

Version : a-e

Date: 07-04-15

GENERAL WELL TOLERANCES DUPLEX

Rise 80m    0   H    5   T   0    P   5    H    E    H    T    D    T    P    Y    P    E    A    E    D    W    D    Y    T    Y    A    I    S    A    W    O    W    T    H    T    S    L    S    I    I    O    A    O    H    I    H    C    I    I    X    R    N    E    I    A    M    M    M    M   0    0   O   5    5   C

   S    M    A    E    B    R    O    T    A    R    A    P    E    S

UNIT A

UNIT B 160

MINI TOTAL HOISTWAY WIDTH 50

50 COMMERCIAL TOTAL HOISTWAY WIDTH

50

50 MAXI TOTAL HOISTWAY WIDTH

FRONT

OPENING

BUILDER'S WORK CATALOGUE 27/38

Lux 

PART 3: INFORMATION CONCERNING BANKS OF LIFTS

FAA29100H_BWC

Version : a-e

Date: 07-04-15

TRIPLEX

Rise 80m    0   H    5   T    P   0    H    E   5   H    T    D    T    P    Y    P    E    A    E    D    D    Y    W    Y    A    T    S    A    W    I    O    W    T    S    H    T    I    S    L    O    A    I    O    H    I    C    H    I    X    R    I    A    E    N    I    M    M    M    0    M    0   O   5    5    C

UNIT A 160

   S    M    A    E    B    R    O    T    A    R    A    P    E    S

UNIT B 160

   S    M    A    E    B    R    O    T    A    R    A    P    E    S

UNIT C

MINI TOTAL HOISTWAY WIDTH 50

50 COMMERCIAL TOTAL HOISTWAY WIDTH

50

50 MAXI TOTAL HOISTWAY WIDTH

FRONT

OPENING

BUILDER'S WORK CATALOGUE 28/38

Lux 

PART 3: INFORMATION CONCERNING BANKS OF LIFTS

FAA29100H_BWC

Version : a-e

Date: 07-04-15

QUADRUPLEX

Rise 80m    H    0    T    P    0    H    5    E    5    T    H    D    T    P    Y    P    E    A    E    D    W    D    Y    T    Y    A    S    I    A    W    O    T    W    H    T    S    I    S    L    I    O    A    I    O    H    C    I    H    I    X    R    A    N    E    I    M    M   0    M    0    M   5    5    O    C

UNIT A 160

   S    M    A    E    B    R    O    T    A    R    A    P    E    S

UNIT B 160

   S    M    A    E    B    R    O    T    A    R    A    P    E    S

UNIT C 160

   S    M    A    E    B    R    O    T    A    R    A    P    E    S

UNIT D

MINI TOTAL HOISTWAY WIDTH 50

50 COMMERCIAL TOTAL HOISTWAY WIDTH

50

50 MAXI TOTAL HOISTWAY WIDTH

FRONT

OPENING

BUILDER'S WORK CATALOGUE 29/38

Lux 

PART 3: INFORMATION CONCERNING BANKS OF LIFTS

FAA29100H_BWC

Version : a-e

Date: 07-04-15

QUINTUPLEX

Rise 80m    0    H    5    T    P    0    E    5    H    H    D    T    T    P    Y    P    E    E    A    D    D    W    Y    T    Y    A    S    A    I    W    O    W    T    T    H    S    S    I    L    I    O    A    O    I    H    H    C    I    I    R    X    N    E    I    A    M    M    M    0    M    5    0    O    5    C

UNIT A

160

   S    M    A    E    B    R    O    T    A    R    A    P    E    S

UNIT B

   S    M    A    E    B    R    O    T    A    R    A    P    E    S

UNIT C

160

   S    M    A    E    B    R    O    T    A    R    A    P    E    S

160

UNIT D

   S    M    A    E    B    R    O    T    A    R    A    P    E    S

UNIT E

160

MINI TOTAL HOISTWAY WIDTH 50

50 COMMERCIAL TOTAL HOISTWAY WIDTH

50

50 MAXI TOTAL HOISTWAY WIDTH

FRONT

OPENING

BUILDER'S WORK CATALOGUE 32/38

Lux 

PART 3: INFORMATION CONCERNING BANKS OF LIFTS

FAA29100H_BWC

3.1.5

Version : a-e

Date: 07-04-15

HOISTWAY DEPTH DIMENSION (PLAN) Same dimensions as the dimensions defined for simplex lift (see Part 1 Para 1.3)

3.1.6

HOISTWAY WIDTH DIMENSIONS HW (PLAN) FOR LIFTS IN THE SAME HOISTWAY DUPLEX Lifts in line in the same hoistway

R Number of passenger

CW

CD

10 pass.

1350

1400

13 pass.

1600

1400

80m

DOOR

OP

THW MINI

THW MAXI

CLD

800

4010

4810

CLD

900

4210

4810

CLD

900

4510

5310

CLD

1000

4510

5310

CLD

1100

4910

5310

17 pass.

2000

1400

CLD

1100

5210

6110

21 pass.

2000

1700

CLD

1100

5210

6110

21 pass.

2100

1600

CLD

1100

5410

6310

DOOR

OP

THW MINI

THW MAXI

CLD

800

4060

4760

CLD

900

4260

4760

CLD

900

4560

5260

CLD

1000

4560

5260

CLD

1100

4960

5260

R Number of passenger

CW

CD

10 pass.

1350

1400

13 pass.

1600

1400

80m

17 pass.

2000

1400

CLD

1100

5260

6060

21 pass.

2000

1700

CLD

1100

5260

6060

21 pass.

2100

1600

CLD

1100

5460

6260

BUILDER'S WORK CATALOGUE 33/38

Lux 

PART 3: INFORMATION CONCERNING BANKS OF LIFTS

FAA29100H_BWC

Version : a-e

Date: 07-04-15

TRIPLEX Lifts in line in the same hoistway

R Number of passenger

CW

CD

10 pass.

1350

1400

13 pass.

1600

1400

80m

DOOR

OP

THW MINI

THW MAXI

CLD

800

6070

7320

CLD

900

6370

7320

CLD

900

6820

8070

CLD

1000

6820

8070

CLD

1100

7420

8070

17 pass.

2000

1400

CLD

1100

7870

9270

21 pass.

2000

1700

CLD

1100

7870

9270

21 pass.

2100

1600

CLD

1100

8170

9570

DOOR

OP

THW MINI

THW MAXI

CLD

800

6120

7270

CLD

900

6420

7270

CLD

900

6870

8020

CLD

1000

6870

8020

CLD

1100

7470

8020

R Number of passenger

CW

CD

10 pass.

1350

1400

13 pass.

1600

1400

80m

17 pass.

2000

1400

CLD

1100

7920

9220

21 pass.

2000

1700

CLD

1100

7920

9220

21 pass.

2100

1600

CLD

1100

8220

9520

BUILDER'S WORK CATALOGUE 34/38

Lux 

PART 3: INFORMATION CONCERNING BANKS OF LIFTS

FAA29100H_BWC

Version : a-e

Date: 07-04-15

QUADRUPLEX Lifts in line in the same hoistway

R Number of passenger

CW

CD

10 pass.

1350

1400

13 pass.

1600

1400

80m

DOOR

OP

THW MINI

THW MAXI

CLD

800

8130

9830

CLD

900

8530

9830

CLD

900

9130

10830

CLD

1000

9130

10830

CLD

1100

9930

10830

17 pass.

2000

1400

CLD

1100

10530

12430

21 pass.

2000

1700

CLD

1100

10530

12430

21 pass.

2100

1600

CLD

1100

10930

12830

DOOR

OP

THW MINI

THW MAXI

CLD

800

8180

9780

CLD

900

8580

9780

CLD

900

9180

10780

CLD

1000

9180

10780

CLD

1100

9980

10780

R Number of passenger

CW

CD

10 pass.

1350

1400

13 pass.

1600

1400

80m

17 pass.

2000

1400

CLD

1100

10580

12380

21 pass.

2000

1700

CLD

1100

10580

12380

21 pass.

2100

1600

CLD

1100

10980

12780

BUILDER'S WORK CATALOGUE 35/38

Lux 

PART 3: INFORMATION CONCERNING BANKS OF LIFTS

FAA29100H_BWC

Version : a-e

Date: 07-04-15

QUINTUPLEX Lifts in line in the same hoistway

R Number of passenger

CW

CD

10 pass.

1350

1400

13 pass.

1600

1400

80m

DOOR

OP

THW MINI

THW MAXI

CLD

800

10190

12340

CLD

900

10690

12340

CLD

900

11440

13590

CLD

1000

11440

13590

CLD

1100

12440

13590

17 pass.

2000

1400

CLD

1100

13190

15590

21 pass.

2000

1700

CLD

1100

13190

15590

21 pass.

2100

1600

CLD

1100

13690

16090

DOOR

OP

THW MINI

THW MAXI

CLD

800

10240

12290

CLD

900

10740

12290

CLD

900

11490

13540

CLD

1000

11490

13540

CLD

1100

12490

13540

R Number of passenger

CW

CD

10 pass.

1350

1400

13 pass.

1600

1400

80m

17 pass.

2000

1400

CLD

1100

13240

15540

21 pass.

2000

1700

CLD

1100

13240

15540

21 pass.

2100

1600

CLD

1100

13740

16040

BUILDER'S WORK CATALOGUE 36/38

Lux 

PART 3: INFORMATION CONCERNING BANKS OF LIFTS

FAA29100H_BWC

Version : a-e

Date: 07-04-15

SEXTUPLEX Dimensions for a single hoistway for 3 Lifts

R Number of passenger

CW

CD

10 pass.

1350

1400

13 pass.

1600

1400

80m

DOOR

OP

THW MINI

THW MAXI

CLD

800

6070

7320

CLD

900

6370

7320

CLD

900

6820

8070

CLD

1000

6820

8070

CLD

1100

7420

8070

17 pass.

2000

1400

CLD

1100

7870

9270

21 pass.

2000

1700

CLD

1100

7870

9270

21 pass.

2100

1600

CLD

1100

8170

9570

DOOR

OP

THW MINI

THW MAXI

CLD

800

6120

7270

CLD

900

6420

7270

CLD

900

6870

8020

CLD

1000

6870

8020

CLD

1100

7470

8020

R Number of passenger

CW

CD

10 pass.

1350

1400

13 pass.

1600

1400

80m

17 pass.

2000

1400

CLD

1100

7920

9220

21 pass.

2000

1700

CLD

1100

7920

9220

21 pass.

2100

1600

CLD

1100

8220

9520

BUILDER'S WORK CATALOGUE 37/38

Lux 

PART 3: INFORMATION CONCERNING BANKS OF LIFTS

FAA29100H_BWC

Version : a-e

Date: 07-04-15

OCTOPLEX Dimensions for a single hoistway for 4 Lifts

R Number of passenger

CW

CD

10 pass.

1350

1400

13 pass.

1600

1400

80m

DOOR

OP

THW MINI

THW MAXI

CLD

800

8130

9830

CLD

900

8530

9830

CLD

900

9130

10830

CLD

1000

9130

10830

CLD

1100

9930

10830

17 pass.

2000

1400

CLD

1100

10530

12430

21 pass.

2000

1700

CLD

1100

10530

12430

21 pass.

2100

1600

CLD

1100

10930

12830

DOOR

OP

THW MINI

THW MAXI

CLD

800

8180

9780

CLD

900

8580

9780

CLD

900

9180

10780

CLD

1000

9180

10780

CLD

1100

9980

10780

R Number of passenger

CW

CD

10 pass.

1350

1400

13 pass.

1600

1400

80m

17 pass.

2000

1400

CLD

1100

10580

12380

21 pass.

2000

1700

CLD

1100

10580

12380

21 pass.

2100

1600

CLD

1100

10980

12780