Omnitrend Quick Engl 082006

Share Embed Donate


Short Description

Download Omnitrend Quick Engl 082006...

Description

1-1

OMNITREND® PC Software for Windows

Getting started

Dear customer,

   4    0  .    4    0    T    R    E    P    X    B    I    V

We are grateful for your trust and hope that you are happy with our product. If you have any suggestions for improving this product or this instruction manual, please let us know. Version 2.1x Edition June 2006 VIB 9.631.G

PRÜFTECHNIK Condition Monitoring Fax: (089) 99616-300 eMail: [email protected]

2

Notes regarding data loss With any data processing software, data may be lost or altered under certain circumstances. PRÜFTECHNIK Condition Monitoring strongly recommends that you make backup copies of all important data on a regular basis. PRÜFTECHNIK Condition Monitoring assumes no responsibility for data lost or altered as a result of improper use, repairs, defects, battery replacement/ failures or any other cause. PRÜFTECHNIK Condition Monitoring assumes no responsibility, directly or indirectly, for financial losses or claims from third parties resulting from the use of this product and any of its functions, such as loss or alteration of stored data, etc.

© 2004 PRÜFTECHNIK PRÜFTECHNIK Condition Monitoring; all rights reserved Both this manual and the product it describes are copyrighted. All rights belong to the publisher. The manual may not be copied, reproduced, translated or made accessible to a third party in any form, neither in its entirety nor as an excerpt. No liability may be claimed against the publisher regarding the product described in this manual. The publisher assumes no liability for accuracy of the manual contents. Furthermore, under no circumstances may the publisher be held liable for direct or indirect damage of any kind resulting from use of the product or the manual, even if the publisher has expressly indicated the potential for occurrence of such damage. The publisher assumes no liability for any product defects. This warranty and liability limitation applies to all distributors and sales partners as well. The trademarks mentioned in this manual are generally noted as such and are the property of their owners. Lack of such designation does not imply, however, that names are not protected by trademark laws.

 O M N  I   T  R  E  N  D   G  e   t    t   i   n  g  s   t    a  r   t    e   d   0   6  .  0   6 

3 Foreword

Foreword Congratulations! And thank you for choosing one the of the tried and tested products of PRÜFTECHNIK Condition Monitoring. Whether it is a handy data collector and vibration analyzer, or one of the intelligent online systems - all PRÜFTECHNIK instruments work with the same PC software and use the same database for archiving the collected measurement data: OMNITREND. The advantages are obvious: • Only one software package to install install and update update • Measure Measurement ment data of all all measurement measurement systems systems are administrated administrated in a single database • Short learning learning curve curve if expanded expanded to include other other PRÜFTECHN PRÜFTECHNIK  IK  measurement systems • Hom Homoge ogeneou neouss data structu structure re OMNITREND helps you in the preparation of measurement tasks, supports you in the analysis of the results and provides a number of  practical functions for the archiving and documentation of results. For further information visit us on the Internet under: http://www.pruftechnik.com

About this manual This operating manual describes the first steps for commissioning the OMNITREND PC software - from installation and starting up the program to registration of the software and individual measurement devices.    6    0  .    6    0    d   e    t   r   a    t   s

  g   n    i    t    t   e    G      D    N    E    R    T    I    N    M    O

Information for the operation of OMNITREND and a complete description of all program functions are contained in the OMNITREND operating manual which is available as a WORD file on the CD ROM. The contents of the OMNITREND operating manual are reflected in the OMNITREND online help which can be called up in the program  with the 'F1' function functi on key. This manual should be freely available for everyone who works with the OMNITREND PC software. This manual is valid for software  version 2.1x and an d higher.

4 Foreword

Contents

What's new? .................................................................. 5 OMNITREND version 2.11 .................................................................. 5

Safety notes ........................................................................ 9

PC requirements ............................................................ 9 Installation ................................................................... 10 Installing OMNITREND PC software & StandardReports .................... 10 PC software installation for Online systems ...................................... 13

Starting OMNITREND .................................................. 16 OMNITREND with Microsoft Access database ................................... 16 OMNITREND with ORACLE database ................................................ 17

Registration.................................................................. 19 Registering the full version ............................................................... 20 Enabling communication with a data collector (offline device) .......... 25 Enabling communication with an Online system ............................... 27 Registering optional software modules.............................................29

Update & Uninstall ...................................................... 30 Uninstalling OMNITREND ................................................................. 31

 O M N  I   T  R  E  N  D   G  e   t    t   i   n  g  s   t    a  r   t    e   d   0   6  .  0   6 

5 What's new?

 What's new? OMNITREND version 2.11 General

• Context-sensitive online help: The online help has been restructured and now displays information relevant to the section from  which you called it up in OMNITREND. • New OMNITREND login window: The new login window lets you select the database and the database type. You can reposition or minimize the window as required. • Extended OMNITREND general settings: The new functions are: Starting of Standard Reports in the background / Conditions for the alarm status check (AlarmCheck) / Display of cursor coordinates / Automatic zoom function / Display of waterfall spectra. Meas. data Viewer

• Linked diagrams: Diagrams within a single window can be linked so that the cursor and zoom function acts on all diagrams at once. • Window arrangement in the MultiView overview: All windows are arranged vertically by default. This arrangement can be changed using the mouse (Drag&Drop). Also, diagrams in the MultiView can now be closed individually. • Simplified zoom function:To magnify an area of the diagram, a frame can be dragged around the area using the mouse. It is no longer necessary to switch between cursor and zoom mode. • More rapid selection of signal measurements: Individual signal measurements at a measurement location can now also be selected in the date field of the diagram. • Buttons for calling up cursors: Three new buttons for the main, delta and harmonic cursors make it easier to call up these cursor functions and use them to evaluate measurement data. • Buttons for calling up frequency markers: A new button in the icon bar can be used to conveniently display the frequency markers in the diagram. Database    6    0  .    6    0    d   e    t   r   a    t   s

  g   n    i    t    t   e    G      D    N    E    R    T    I    N    M    O

• Database optimization: Applying the new database compression function to the database will shrink the database to about half its size on average. This function is found under  Database / Database utilities.

• Deleting measurement data: The same menu contains a function for deleting older measurement data from the database. The date is entered as the deletion criterion. Machinery manager

• Measurement tasks can now be deactivated within the route: The existing option for online systems for hiding measurement tasks in

6 What's new?

a measurement cycle has been extended to work with data collectors. You can now exclude individual measurement locations and tasks from a measurement route. This change became necessary because measurement tasks no longer appear in the route editor and therefore cannot be removed from the route. • Adaptive measurement task: For the same reason as above, the function for setting up an adaptive measurement task was moved to the Machinery Manager. To set up an adaptive measurement task, use Drag&Drop to drag the measurement task to the new ‘Adaptive measurement task’ tab. • ‘Additional info’ tab enhanced: You can now save additional information for each Location and Database hierarchy. Alarm editor

• Synchronizing / deleting alarm bands: You can synchronize or simultaneously delete alarm bands from different measurement tasks. This function can only be used in combination with the MultiEdit Wizard. • Alarm mask is now defined as a (broad) alarm band: The alarm mask is no longer defined as the baseline of all narrowband alarm bands. It is now a so-called alarm baseband that encompasses all frequencies not monitored in a narrow alarm band. Thus, a band analysis can also be set up for the alarm baseband, i.e. a characteristic value can be recorded as a trend. • Edge values for (broad) alarm bands: The width of  RPM-independent alarm bands can now be entered using edge values (f1 and f2). However, the alarm editor always shows the corresponding  values for the center frequency and the bandwidth. • Offset alarm level can be calculated from several basic spectra: When setting up alarm levels on the basis of an offset (% or absolute), you can now use multiple base spectra for the calculation. The offset is calculated from the linear average value across all base spectra. • Alarm type as new alarm band parameter:  Peak is the largest amplitude, and Power is the signal power in the alarm band.  Alarm editor for online system:

Dynamic adjustment of alarm level • In variable-speed measurements, the alarm level can be adjusted using polynomial functions. The polynomial parameters are entered in OMNITREND and loaded into the online system together  with the measurement cycle. The alarm level then tracks the RPM in the online system. Route editor

• New Route Editor design: The Route Editor layout corresponds to that of the Template Editor. The Route Editor now contains a route list for the convenient selection of individual routes and provides  various processing functions (New, Delete, Copy...).

 O M N  I   T  R  E  N  D   G  e   t    t   i   n  g  s   t    a  r   t    e   d   0   6  .  0   6 

7 What's new?

• Display filter for route hierarchies: In the Route Editor you can set the hierarchies that should be displayed for the route: only the machine trains in the route, only the machine trains and machines in the route, or machine trains, machines and measurement locations in the route.  ATTENTION! Unlike the earlier version, measurement tasks are not displayed in the Route Editor. The  Disable in route assignment is made in the Machinery Manager (‘Measurement type’ tab). Consequently, the ‘adaptive measurement tasks’ for the route are now set up in the Machinery Manager (‘Adaptive measurement task’ tab at the Measurement Task level).  Route for VIBXPERT:

Order of measurement locations can be changed as required • The order of measurement locations in the route can be changed independent of their position in the tree structure.  Route for VIBXPERT:

 Adjustable measurement channel • For each measurement location you can define whether measurements should be made with channel A or channel B.  Measurement cycle for online system:

• Sorting of measurement locations (=channels) according to online system: In the Route Editor, you can select the online system for  which you would like to create the measurement cycle. Measurement locations associated with another system in the Machinery  Manager are sorted out. • Expanded filter options for route transfer to the device: The following transfer options are available in addition to the existing options (all measurement locations / due measurement locations or measurement locations with alarm): Only transfer measurement locations of machines or machine trains with alarm. Only transfer measurement locations of machines or machine trains that are due. Transducer editor

   6    0  .    6    0    d   e    t   r   a    t   s

  g   n    i    t    t   e    G      D    N    E    R    T    I    N    M    O

• Units and labels for user-defined parameters: For calculated measurement parameters you must enter the unit and label for the X  and Y axes. Setup editor

• AC-DC filter for VIBROWEB XP: Filters for signal measurement  with VIBROWEB XP / WinTControl are now set up in the Setup Manager. Duplicate a corresponding factory setup to change the filter settings. In earlier versions, the filter setting was located in the ‘Device instructions’ tab.

8 What's new?

Template editor

• Production test: This option is used to deactivate automatic  processing of a machine template with VIBXPERT. Doing so will let you perform the same measurement task a number of times. This is useful during a production test, for example, where you can carry  out the same measurement task under varying operating conditions. The individual measurement tasks in the template are called up manually. Standard Reports

• New report module based on OMNITREND WebReport: Standard Report is a free add-on to the OMNITREND reporting feature. It offers a limited selection of functions available in WebReport. Online systems

• eMail to multiple recipients: eMails can be sent from the online system to up to 10 different recipients (VIBNODE: max. 3 recipients). The settings are located in the configuration window under Options / Edit.

(In VIBNODE: configuration window under eMail) • Data import via external drive (USB stick): Measurement data from the online system (except for VIBNODE) can now be imported into the database from an external drive, such as a USB stick. This option is found in the configuration window in the  Import channel field.

 O M N  I   T  R  E  N  D   G  e   t    t   i   n  g  s   t    a  r   t    e   d   0   6  .  0   6 

9 PC requirements

PC requirements OMNITREND runs on any desktop or laptop PC that meets the following minimum configuration requirements: Operating system (OMNITREND for data collector - offline)

Windows 98 SE / 2000 (SP2) / XP Operating system (OMNITREND for Online systems)

Windows 2000 (SP2) / XP (SP1) Processor

Pentium III 400 MHz or faster; 1,8 GHz recommended RAM

256 MB; 512 MB recommended Hard disk

600 MB free, 1GB recommended Drive

CD-ROM required for program installation Monitor

 VGA Color (800 x 600) Mouse

required Interface

RS232 (USB to RS232 converter* where applicable), Ethernet for Online systems (recommended for VIBXPERT) Java

Sun Java Runtime 1.4.2_08 (+ Security run time parameter)

* Recommended: D-Link DU-CS  Belkin F5u103 / F5u109 Quatech SSU-100  Xircom PGSDB9

Browser for Online Help

Mozilla all versions; Internet Explorer 5 or later Printer

Windows-compatible

   6    0  .    6    0    d   e    t   r   a    t   s

  g   n    i    t    t   e    G      D    N    E    R    T    I    N    M    O

Safety notes

The OMNITREND database contains important machine information whose loss can result in considerable costs. Thus, a reliable data backup system (‘Backup’) is necessary to avoid consequential damage arising from data loss. The data collector / Online system firmware must be updated to the newest version.

Attention !

10 Installation

Installation * = 'OMNITREND for product name' or 'Condition Monitoring Suite' (VIB 8.970)

Installing OMNITREND PC software & StandardReports • Insert the PRÜFTECHNIK CD-ROM* into the CD drive and wait for the starting screen to appear. If the CD does not start automatically, double-click on the ‘Start.exe’ file in the CD directory.

• For a new installation click on , then click on :

 Note

Windows 2000 / XP: Administrator rights are required for installation. In order to use ORACLE or MS SQL databases respectively, the appropriate ODBC driver is required. Networks: OMNITREND only supports single terminal login. No more than one user can log into the program at the same time.

 O M N  I   T  R  E  N  D   G  e   t    t   i   n  g  s   t    a  r   t    e   d   0   6  .  0   6 

11 Installation

The installation program starts: • Select the language for installation and click on :

In accordance with the subsequent installation note, close all open applications - particularly all AntiVirus programs and Personal Firewalls. Click on to continue.... Java Installation

The Java environment required for StandardReports is installed automatically, regardless of whether another Java environment is already found on the computer or not. The software is installed locally in the ‘Prüftechnik’ directory (C:/ Programme/Prueftechnik/_jvm/).

   6    0  .    6    0    d   e    t   r   a    t   s

  g   n    i    t    t   e    G      D    N    E    R    T    I    N    M    O

Once JAVA has been successfully installed, the installation of the OMNITREND software follows.

12 Installation

OMNITREND installation

• Select 'OMNITREND PC software' and 'OMNITREND StandardReport' and click on .

• In the following screen, click on to start the installation. The OMNITREND PC software is installed first, followed by the installation of OMNITREND Standard Reports.

 Note

OMNITREND Standard Report is an extra program provided freeof-charge for creating reports from the data of the OMNITREND database. To complete the installation, the PC must be restarted.

 O M N  I   T  R  E  N  D   G  e   t    t   i   n  g  s   t    a  r   t    e   d   0   6  .  0   6 

13 Installation

PC software installation for Online systems VIBRONET Signalmaster / VIBROWEB / VIBROWEB XP

In order to communicate with the online system and to exchange data, the following files and programs must be installed on the PC. - JAVA plug-in for displaying JAVA applets in the browser - Browser for displaying the HTML pages (user interface) - FTP server (Serv-U) for exchanging data via FTP In addition, the data server and the directories required for archiving data are installed on the PC. The installation program checks whether the necessary components are already installed on the PC and  whether the versions fulfill requirements. If necessary, the programs listed above will be re-installed or updated. • Insert the OMNITREND CD* into the CD drive and wait for the starting screen to appear. If the CD does not start automatically, double-click on the ‘Start.exe’ file in the CD directory. • Click on “Online Systems”, and then on “Start installation” to install the software:

   6    0  .    6    0    d   e    t   r   a    t   s

  g   n    i    t    t   e    G      D    N    E    R    T    I    N    M    O

• In accordance with the subsequent installation note, close all open applications - particularly all AntiVirus programs. Click on to continue.

* = 'OMNITREND for product name' or 'Condition Monitoring software' (VIB 8.970)

14 Installation

The Java components are installed next.

 Note

The Java plug-in is required to correctly display the Java Applets of  the HTML pages. The HTML pages form the user interface of the online system during access via browser. If an unsupported Java  version is already installed on the PC (any version, except version 1.4.2_XX), you must delete this before continuing with the installation. • Select the "Install this program" option and click on . • Confirm the resulting license agreement for the Java Plug-in and click on . • In the next window select the ‘Typical’ option as the type of  installation and click on . • Select the browser for which the Java Plug-in should be registered. Click on to start the Java installation. • Then click on to complete the installation of the Java Plug-in. The software components required for online systems on the PC (FTP server, data server, station directory) are then installed.

 Note

The FTP server is required to transfer the data from the online system to the PC and back. The data server converts the measurement data into an OMNITREND-compatible format. The configuration files, measurement cycles and measurement data of the corresponding online system are located in the station directory. • Confirm the software license agreement and click on . • Enter the installation directory and click on . Standard directory = ‘C:/pt_cm/online’.

 Note

The FTP server is installed in the installation directory intended for Windows programs (e.g. ‘Program_files’). Note that the FTP server and the remaining components must be installed on the same disk  drive (e.g. ‘C:’). The FTP server is set up as a ‘System Service’. Thus the program starts automatically as soon as data is requested from the online system. • In the next window click on and restart the PC to complete the installation.

 O M N  I   T  R  E  N  D   G  e   t    t   i   n  g  s   t    a  r   t    e   d   0   6  .  0   6 

15 Installation

The following directories are created in the installation directory: data (import directory for the data server) .../data software/autoimport .../software/autoimport software/autoimport (data server) station_name (station directory for the online system (= name .../station_name of the system)) • Create a desktop link to the file  Installation path  /software/autoimport/autoimport.bat /software/autoimport/autoimport.bat This link is used later to start the data server.  Additional online systems can be added or current systems deleted/ renamed directly in OMNITREND.

   6    0  .    6    0    d   e    t   r   a    t   s

  g   n    i    t    t   e    G      D    N    E    R    T    I    N    M    O

16 Starting OMNITREND

Starting OMNITREND OMNITREND with Microsoft Access database

• Click on in the Windows task bar. • Click on in the START menu, and enter the program path: C:\Programs \ Pruftechnik \ Omnitrend \ Omnitrend.exe

If OMNITREND is in another directory, enter the corresponding path. The OMNITREND login window appears:

• Enter the user name and the password if necessary, and click on . If you are starting the program for the first time, enter the user name 'guest'. The database that was used last is opened; the first time the program is started, this is the demo database. • If you would like to open another database, click on or respectively, to open the 'Recent databases' pull down menu or the 'File select' dialog window. • Select the new database file (*.mdb) and click on .

 O M N  I   T  R  E  N  D   G  e   t    t   i   n  g  s   t    a  r   t    e   d   0   6  .  0   6 

17 Starting OMNITREND

OMNITREND with ORACLE database

In order for OMNITREND to be able to open an ORACLE database, the optional ‘ORACLE’ module must be registered. Use a standard 'Access' database to start OMNITREND for registration (p. 29). • Start OMNITREND (see previous section):

• Select ‘Open ORACLE / ... Database’, and then click on

:

   6    0  .    6    0    d   e    t   r   a    t   s

  g   n    i    t    t   e    G      D    N    E    R    T    I    N    M    O

• Open the ‘Computer data source’ tab, and select the ORACLE database (here: ‘OMNI_ORC’). Click on :

             Note

18 Starting OMNITREND

• Select the ORACLE file to be opened in the selection list on the right (here: ‘A_VIBSCANNER’; Equivalent to an OMNITREND (access) database). • Then click on .

 Note

If you have any questions about ORACLE, please contact your ORACLE administrator.

 O M N  I   T  R  E  N  D   G  e   t    t   i   n  g  s   t    a  r   t    e   d   0   6  .  0   6 

19 Registration

Registration The registration procedure in OMNITREND consists mainly of three parts: Registering the full version

OMNITREND is delivered as a demo version where the route function and data exchange are inactive. The user can only work with the demo database that is supplied in order to find out how to use the program. In order to evaluate the user’s own measured data and to create routes, the full version must be activated with a registration password. The password for the purchased OMNITREND version (e.g. ‘OMNITREND for VIBROTIP’, VIB 8.862) is free-of-charge but must be requested by ‘Return Fax’ and entered in OMNITREND as described in the following section. A charge is made for the registration of any  additional device types (e.g. VIBSCANNER, VIBXPERT, VIBROWEB, etc.). Activating communication with OMNITREND

So that the data collector / online system can receive routes and transmit measured data to the PC, it must be registered in OMNITREND with its individual serial number. A so-called ‘PC licence’ for one device is included in the scope of delivery. For each further device, a charge is made for the PC licence. Registering optional software modules

The range of functions of the OMNITREND software can be extended as required. -

Gear editor - VIB 8.961 Signal analysis - VIB 8.962 ORACLE databse - VIB 8.963 SQL database - VIB 8.964

 A charge is made for the passwords required for registration.

   6    0  .    6    0    d   e    t   r   a    t   s

  g   n    i    t    t   e    G      D    N    E    R    T    I    N    M    O

20 Registration

Registering the full version

 Note

Definition  Measurement device = an individual device identified by its ID

number. OMNITREND version (= device type ) = OMNITREND for the

appropriate device type (e.g. OMNITREND for VIBSCANNER).  Device type = All measurement devices of the respective type (z.B.

all VIBSCANNER devices). OMNITREND is a multi-device software that works with the following PRÜFTECHNIK measurement devices:

 After the first-installation of OMNITREND, the software runs in the demo mode for the purchased device type. Example: If you have purchased ‘OMNITREND for VIBSCANNER’ (VIB 8.955) you will have the following start screen after the first installation:

OMNITREND for VIBSCANNER runs in the demo mode

In the demo mode the following functions are locked: • Data exchange • Route Editor

 O M N  I   T  R  E  N  D   G  e   t    t   i   n  g  s   t    a  r   t    e   d   0   6  .  0   6 

21 Registration

To register the full version, proceed as follows: 1. Click on / :

1.

2. Click on

2.

3. Enter the customer data (Company name / Address) and the CD serial number* 4. Select the device version if applicable **.

   6    0  .    6    0    d   e    t   r   a    t   s

  g   n    i    t    t   e    G      D    N    E    R    T    I    N    M    O

* This 10-digit number is given on the OMNITREND CD ROM. **Standard, View, LE (only for VIBXPERT, VIBSCANNER, Signalmaster)

3.

4.

22 Registration

From these data, OMNITREND calculates an identification number that is displayed in the 'ID No.' field. This number is used to generate the registration password.

Attention!

Do not change these data under any circumstances after registration. Otherwise, the ID number will also be changed and the registration will be deleted when you start the program. OMNITREND then has to be registered once more (New password, new certificate, ...). In this case a handling fee will be charged (77 EURO)! So, be careful, when entering the customer data and the software number. If there is an error in the text, it will be an error that will be printed on every report page. Data inputs are case-sensitive! Example: In the next screen the company name is the same as before except that ‘Pruftechnik’ is written in capital letters ‘PRUFTECHNIK’. As a result, the ID number has changed:

The company name is the same except that PRUFTECHNIK is written in capital letters.

ID number has changed (see previous page)

5.

5. Print out the return fax using .  O M N  I   T  R  E  N  D   G  e   t    t   i   n  g  s   t    a  r   t    e   d   0   6  .  0   6 

23 Registration

6. Send the Return Fax to PRÜFTECHNIK 

6. Fax: +49(0)89 99 61 63 00

 You will receive the password required for registration within 24 hours (workdays) via fax. The original registration certificate will be send by mail.

Certificate

F     a    x   

VIB x.xxx max.24h Fax

PASSWORD

Reference numbers of the registration certificates:    6    0  .    6    0    d   e    t   r   a    t   s

  g   n    i    t    t   e    G      D    N    E    R    T    I    N    M    O

VIB 5.480-OMT: VIB 8.956-OMT: VIB 8.957-OMT: VIB 8.958-OMT: VIB 5.690: VIB 5.692: VIB 5.694: VIB 8.862-P: VIB 8.960-OMT: VIB 8.980-OMT: VIB 8.981-OMT: VIB 7.780-OMT:

OMNITREND for VIBSCANNER Standard OMNITREND for VIBSCANNER View OMNITREND for Signalmaster Standard OMNITREND for Signalmaster LE OMNITREND for VIBROCORD A OMNITREND for VIBROCORD C OMNITREND for VIBROCORD View OMNITREND for VIBROTIP OMNITREND for VIBROSPECTFFT (SYSTEM 2) OMNITREND for VIBROWEB OMNITREND for VIBXPERT OMNITREND für VIBROWEB XP

24 Registration

7. Upon receiving the registration password open the registration  window (see 1. & 2.) and click on :

7.

8.

8. Enter the password (8 upper case letters) and click on . If the password is correct, the full version is registered.

9. Exit OMNITREND and start the program again in order for the registration to become effective.

 Note

Two or more databases The registration is database-dependent, i.e. if you change to another database, you may have to register the full version again under certain circumstances. Software updates Software updates do not affect the registration!

 O M N  I   T  R  E  N  D   G  e   t    t   i   n  g  s   t    a  r   t    e   d   0   6  .  0   6 

25 Registration

Enabling communication with a data collector (offline device)  After registering the full version for the purchased OMNITREND  version (= device type), you can now register your actual data collector in OMNITREND. This also activates the device for communication with OMNITREND.

OMNITREND

ESC

H  E  

L P 

   6    0  .    6    0    d   e    t   r   a    t   s

  g   n    i    t    t   e    G      D    N    E    R    T    I    N    M    O

F

  U

  N  M  E

VIBXPERT PC Licence

VIBSCANNER PC Licence

VIBROTIP PC Licence

Registration Certificate VIB 8.981-P

Registration Certificate VIB 5.480-P

Registration Certificate VIB 8.862-P

Serial No. ID No.

0123456789 12345678

Serial No. ID No.

0123456789 12345678

Serial No.

0123456789

Password

ABCDEFGH

Password

ABCDEFGH

Password

ABCDEFGH

The ‘PC licence’ registration certificate includes the password that enables the communication with OMNITREND for the respective device. The PC licence is delivered with the device. The device types 'VIBROSPECT FFT (device)' and 'VIBROSPECT RAM File' do not have a ‘PC licence’ registration.

             Note

26 Registration

To register the individual device, proceed as follows: 1. Click on / :

1.

2. Click on the ‘Measurement device’ property sheet.

2.

3. 4.

3. Enter the ID number of the device in the 'ID' field.  You can directly read in the ID / serial number of your device. - To do this, connect the device to the PC. - Switch on the device. - Click on . - Enter the communication port and click on . 4. Click on . 5. Enter the password and click on .

5.

 O M N  I   T  R  E  N  D   G  e   t    t   i   n  g  s   t    a  r   t    e   d   0   6  .  0   6 

27 Registration

Enabling communication with an Online system The activation of communication with an online system is different from the activation of a measurement data collector. Therefore, follow the instructions given below if you want to activate one of the online systems listed below in OMNITREND:

 VIBROWEB XP, VIBROWEB, VIBRONET Signalmaster, VIBNODE, WinTControl 1. Ensure that the online system is correctly connected in the network  and is switched on. If you want to contact the online system by  modem, set up the remote data transfer connection first. 2. Click on / :

2.

3. Click on the ‘Measurement device’ property sheet and then click on . 4. Enter the IP address and, if necessary, the subnet mask as well as the gateway of the online system. Then click on :

3.

   6    0  .    6    0    d   e    t   r   a    t   s

  g   n    i    t    t   e    G      D    N    E    R    T    I    N    M    O

4.

28 Registration

5. Enter the name of the Online system. This is the same as the station directory that was created during the installation (default: ‘station_name’). Click on .

5.

6. The ID number of the Online system is transfered and appears in the ‘ID’ field. Click on and enter the password:

6.

7.

7. Finally click on .

 O M N  I   T  R  E  N  D   G  e   t    t   i   n  g  s   t    a  r   t    e   d   0   6  .  0   6 

29 Registration

Registering optional software modules OMNITREND can be upgraded with the following software modules:

• Gear editor (VIB 8.961) • Signalanalysis for VIBSCANNER (VIB 8.962) Upgrades OMNITREND for VIBSCANNER by the: - Import of time signals (MultiMode/ Route) and Orbit measurements (Multimode) - Import of recording measurements (MultiMode) - Import of balancing data - Gear editor • ORACLE / SQL database (VIB 8.963 / VIB 8.964) When ordering, enter the 10-digit serial number of the OMNITREND CD and the OMNITREND ID number (see section 'Registrering the full version ').

             Note

1. Click on / :

1.

2. Click on the ‘Add. features’ tab and select the function to be registered (e.g. Gear frequency editor). Click on . 3. Enter the password, and click on .

2.    6    0  .    6    0    d   e    t   r   a    t   s

  g   n    i    t    t   e    G      D    N    E    R    T    I    N    M    O

3.

30 Update

Update & Uninstall If the OMNITREND PC software has already been installed on your PC, the so-called 'Update Patch' only needs to be started to update the program. This file is supplied on the current CD ROM (see next page), or it can be downloaded from the PRÜFTECHNIK homepage on the Internet: http://www.pruftechnik.com/cm/downloads/sw_all_products.htm

Download site

Update patch on the PRUFTECHNIK homepage

To update an existing OMNITREND version, install the ‘UpdatePatch’ as follows: From the PRÜFTECHNIK homepage:

• Enter the Internet address in your browser (see above). • Select your language version from the pull down menu in the 'OMNITREND' field and save the 'UpdatePatch' (*.exe file) on your PC. • Double-click the file to start the UpdatePatch.

 O M N  I   T  R  E  N  D   G  e   t    t   i   n  g  s   t    a  r   t    e   d   0   6  .  0   6 

31 Deinstallation

From the PRÜFTECHNIK CD-ROM:

• Insert the CD into the CD drive and wait for the starting screen to appear (s. page 10). • Click on 'OMNITREND' and then on 'Start Intstallation/ Update'. • Select 'OMNITREND PC software (Update)' and click on .

• In the following screen, click on to continue.... • Select 'Modify' and click on . The installation begins...

• Restart the PC after installation.    6    0  .    6    0    d   e    t   r   a    t   s

  g   n    i    t    t   e    G      D    N    E    R    T    I    N    M    O

• Start OMNITREND to convert the existing database. Log into OMNITREND under a user name with administrator rights to carry  out the conversion.

Uninstalling OMNITREND

• Open the Windows START menu and select / . • Open the 'Software' module. • Select 'OMNITREND' and click on .

View more...

Comments

Copyright ©2017 KUPDF Inc.
SUPPORT KUPDF