NodeB Upgrade and Comissioning
Short Description
Download NodeB Upgrade and Comissioning...
Description
Document Title
Securit y Level:
1.1 Preparative 1.1.1 NodeB Configuration file For example:
1.1.2 RAN11 NodeB software For example:
1.1.3 NodeB LMTs LMT DBS3900 WCDMA V200R011C00SPC110 VER LMT DBS3900 WCDMA V200R010C01SPC300 VER
1.2 Log in the NodeB by LMT 1.2.1 Set your laptop IP address Set your laptop IP address is 17.21.2.14 (mask: 255.255.255.0)
1.2.2 Connect Ethnet cable between laptop and NodeB comissioning port The commissioning port is the ETH port in the WMPT board of BBU3900 2015-0908
HUAWEI Confidential
Pag e1, Total6
Document Title
Securit y Level:
1.3 Upgrading the NodeB on the LMT
The CPU overload alarm may be generated during the following operations:
Downloading the NodeB software package
Activating the NodeB software
Activating the board software
The alarm is automatically cleared after the upgrade.
1.3.1 Procedure of Upgrade Figure 1.1 shows the procedure for upgrading the NodeB on the LMT. Figure 1.1 Procedure for upgrading the NodeB on the LMT Determine the upgrade site Confirm the configuration baseline Upgrade the NodeB software Verify the upgrade Upgrade successful? Yes
No
Roll back the NodeB version
Finish the upgrade
1.3.2 Confirming the Configuration Baseline For version rollback after the upgrade, you need to confirm the Configuration Baseline (CB) after latest configuration modification before the upgrade. 2015-0908
HUAWEI Confidential
Pag e2, Total6
Document Title
Securit y Level:
Run the CFM CB command to confirm the current CB. It is recommended that Confirm Mode be set to UNFORCED, which is the default value of the parameter. Because the name of the CB cannot be duplicated, the CB might be named with the corresponding current active version and date, such as Oldversion_March 11, 2010. (Commissioning date).
1.3.3 Upgrading the NodeB Software To upgrade the NodeB software, perform the following steps: Step 1 On the NodeB LMT, click the Maintenance tab in the navigation pane. Step 2 Double-click Software Management > Software Update. The Software Update dialog box is displayed, as shown in Figure 1.1. Figure 1.1 Starting to upgrade the NodeB software
2015-0908
HUAWEI Confidential
Pag e3, Total6
Document Title
Securit y Level:
Step 3 Select Upgrade NodeB Software, and then click Next. The Update NodeB Software dialog box is displayed. Step 4 Select the Download NodeB Software Package, Activate NodeB Software, and Download by Configuration check boxes, and enter the NodeB software package path (for example, D:\DBS3900\DBS3900 WCDMA V200R011C00SPC110 VER\Publish) in the Directory Name box, as shown in Figure 1.1. For the reason why the Download by Configuration check box is selected, refer to section Error: Reference source not found"Error: Reference source not found."
Figure 1.1 Upgrading the NodeB software
Step 5 Click Next.
2015-0908
HUAWEI Confidential
Pag e4, Total6
Document Title
Securit y Level:
A dialog box is displayed, indicating the status and progress of the NodeB software upgrade. After the NodeB software activation is complete, the boards whose software is activated and those whose software fails to be activated are listed. If there are boards whose software fails to be activated, perform troubleshooting by referring to section Error: Reference source not found"Error: Reference source not found." ----End
1.3.4 Verifying the Upgrade Table 1.1 Verifying the upgrade on the LMT Item
Instruction
Conclusio n
1
Checking current alarms
Check all the current alarms of the upgraded NodeBs on the LMT, and clear the alarms according to the alarm online help.
-
2
Checking the cell status
Run the DSP LOCELL command on the LMT to check the status of all the cells controlled by the upgraded NodeBs.
-
Check whether all the local and logical cells configured are available.
If yes, the upgrade is successful.
If no, refer to the alarm online help for troubleshooting.
3
Querying the active NodeB version
Run the LST VER command on the LMT. Then, check whether the active NodeB software version is V200R011C00SPC110. There is no need to confirm the BootROM version for the BootROM does not need to be upgraded.
-
4
Performing a dial test
Conduct the test by following the instructions provided in section Error: Reference source not found"Error: Reference source not found." Ensure that the system services are not affected after the NodeB upgrade.
-
5
Determining whether the KPIs are normal
Determine whether the KPIs are normal by following the steps in section Error: Reference source not found"Error: Reference source not found".
-
2015-0908
HUAWEI Confidential
Pag e5, Total6
Document Title
Securit y Level:
1.3.5 Confirming the Configuration Baseline (Optional) Run CFM CB as required to confirm the current configuration baseline
1.3.6 after commissioning 1- SET BOOTPSWITCH : Boot time=120 2- RMV IUBCP : CPPT=CCP 3- RMV SCTPLNK : SCTP link NO=1 4- ADD SCTPLNK : SCTP link NO=1 ; Subrack No=0 ; Slot No=7 ; Local IP Address="NodeB IP" ; Local SCTP port= 8101 ; PEER IP="10.161.35.9"; PEER SCTP PORT=58080;
5- ADD IUBCP : NCP/CCP port type=CCP ; NCP/CCP peering type= IPV4 ; SAAL/SCTP link No=1
2015-0908
HUAWEI Confidential
Pag e6, Total6