PREPARATION OF BILLS OF QU
USING BESMM 4 AND
BILLS OF QUANTITES DESCRI
BY Mr. AYOOLA I. OGUNKANMI PUBLIC BUILDING DEPARTMENT FEDRAL CAPITAL DEVELOPMENT AUTHORITY
1
GARKI ABUJA
SUBSTRUCTURE 1.5: EXCAVATING AND FILLING 2.1.1 2.1.2 4.1.1
Removing Trees; (Provisional) Girth 500 - 1500mm; Filled with laterite Girth 1500 - 3000mm; Ditto
Nr. Nr.
Site Clearance; Clearing Site vegetation and other growth and dispose off site; entire site
Sq.m
5.2.0
Site Preparation; Remove topsoil 150mm deep
Sq.m
6.2.1
Excavation, commencing from stripped level; Foundation excavation; Not exceeding 2m deep
Cu.m
Extra Over Foundation excavation; (Provisional) Excavating in; below ground water level
Cu.m
7.1.3 7.2.1
9.1.1 9.2.0
11.1.2
11.2.2
Breaking up; Rock
Cu.m
Disposal Gound Water; 600mm below original ground level Excavated material off site
Item Cu.m
Filling obtained from excavated material Final thickness of filling not exceeding 500mm deep 500mm thick; Site, not more than 200mm around site, backfilling foundations; in layers average depth 250mm
Sq.m
Final thickness of filling exceeding 500mm deep 500mm thick; Site, not more than 200mm around site, backfilling foundations; in layers average depth 250mm
Sq.m
Graded Laterite
2
12.2.1
Imported Filling; Beds 50mm - 500mm deep 300mm thick; Level, to falls and cross falls
Cu.m
Granite or other equal and approved Hardcore football size 12.2.1
Imported Filling; Beds 50mm - 500mm deep 300mm thick; Level, to falls and cross falls
Cu.m
To Collecton
EXCAVATING AND FILLING (Cont'd) Approved quality 1mm thick damp proof membrane 16.2.1
Damp Proof Membrane; Over 500mm wide, 1mm thick; Horizontal
Sq.m
1.11: INSITU CONCRETE WORKS 1.1.2/1
2.1.1/1
2.2.2/2
5.1.1/1
Grade 30 Concrete Mass Concrete; 225mm thick; In trench filling; Poured on or against earth or unblinded hardcore
Cu.m
Weak Concrete (1:10 - graded sub base) Horizontal Work; less or equal to 300 thick; in blinding; poured on or against earth or unblinded hardcore
Cu.m
Grade 25 Concrete Horizontal Work Over 300mm thick; In structures; Reinforced less or equal to 5%.
Cu.m
Vertical Work; less or equal to 300mm thick; in structures; Reinforced 5%
Cu.m
3
Formwork
13.1.0 13.2.0
Plain formwork Sides of foundations and bases; less or equal to 500mm high: 450mm wide over 500mm high
Lin.m Lin.m
14.1.0
Edges of horizontal; less or equal to 500mm high: 150mm
Lin.m
20.1.0
Sides of isolated Columns 188Nr.; Regular rectangular shape
Sq.m
Reinforcement
34.1.2
High yield steel bars 20mm diameter; Bent;
Tonnes
34.1.2
16mm diameter; Bent;
Tonnes
34.1.2
10mm diameter; Links
Tonnes
37.1.0
Mesh; 4.52kg/sq.m Ref. A152 minimum laps 150mm
Sq.m
To Collection
1.14: MASONRY Brick/Block Walling Hollow sandcrete blockwall beded and jointed in cement and sand (1:6)
1.2.1/1
Walls; 225mm thick; blockwork; skin of hollow walls; laid in stretcher bond Cement and Sand (1:1)
4
Sq.m
16.1.3
Damp Proof Course less or equal 300mm wide; 50mm thick; Horizontal
Lin.m
1.28: FLOOR WALL CEILING AND ROOF FINISHINGS Cement and sand (1:4) smooth rendering 7.1.0
Plastering to Walls 12mm thick; Less or equal to 600mm
Lin.m
1.29: DECORATIONS Dulux or other equal and approved latex paint one coat; cement floated wall sandpapered smooth and one coat of primer on floated wall. 1.2.2
Painting to general surfaces; Over 300mm girth; external
To Collection
SUBSTRUCTURE CARRIED TO SUMMARY
FRAMES 1.11: INSITU CONCRETE WORKS 5
Sq.m
Insitu Concrete Grade 25 Concrete 5.1.1/1
Vertical Work; less or equal to 300mm thick; In structures Reinforced less or equal to 5%
Cu.m
Formwork Plain Formwork 20.1.0
Sides of Isolated Columns, 34Nr.; rectangular
Sq.m
Reinforcement
34.1.1*2
High yield steel bars; 20mm diameter; Straight and Bent
Tonnes
34.1.1*2
16mm ditto
Tonnes
34.1.1*2
10mm diameter; Links
Tonnes
FRAMES CARRIED TO SUMMARY
6
UPPER FLOORS 1.11: INSITU CONCRETE WORKS Insitu Concrete Grade 25 Concrete
2.1.2/2
2.2.2/2
Horizontal Work; less or equal to 300mm thick; In structures; Reinforced less or equal to 5% Over 300mm thick ditto
Cu.m Cu.m
Formwork Plain Formwork 14.1.0
15.1.1
18.1.0
Edges of Horizontal; Width less or equal to 500mm: 150mm wide
Lin.m
Soffits of Horizontal Work; For concrete less or equal to 300mm thick; Propping less or equal to 3m high
Sq.m
Sides and soffit of attached Beams; Rectangular
Sq.m
Reinforcement
34.1.1*2
High yield steel bars; 20mm diameter; Straight and Bent
Tonnes
34.1.1*2
16mm ditto
Tonnes
34.1.1*2
12mm ditto
Tonnes
34.1.1*2
10mm diameter; Links
Tonnes
7
UPPER FLOORS CARRIED TO SUMMARY
STAIRCASES 1.11 INSITU CONCRETE WORKS PLAIN IN SITU CONCRETE REINFORCED Grade 25 Concrete 2.1.2
4.2.3/2
Horizontal Works; less or equal to 300mm thick in Structures
Cu.m
Sloping Works over 150 ; over 300mm thick; in staircases; Reinforced less or equal to 5%
Cu.m
FORMWORK Plain formwork 14.1.0
Edges of horizontal; less or equal to 500mm high: 150mm wide
Lin.m
Soffits of horizontal works; for concrete less or equal to 300 thick; propping less or equal to 3m high
Sq.m
25.1.0
Soffit of sloping work; sloping one way
Sq.m
26.1.0
Staircase strings and the like; maximum width 380mm
Lin.m
27.1.0
Staircase Risers and the like; Vertical 150mm wide
Lin.m
15.1.1
8
REINFORCEMENT
34.1.1*2
High yield steel bars 16mm diameter straight and bent
Tonnes
34.1.1*2
12mm ditto
Tonnes
34.1.1*2
10mm diameter; Links
Tonnes
TO COLLECTION
STAIRCASES (Contd) 1.28: FLOOR WALL CEILING AND ROOF FINISHINGS Cement and sand (1:4) smooth rendering
7.2.0 7.1.0
Plastering to Walls 12mm thick; over 600mm wide
Sq.m
Less or equal to 600mm
Lin.m
600 X 600 X 15mm thick Vitrified Tile
2.1.0 2.2.0
Finish to floors, Vitrified Tiles 50mm thick overall thickness; less or equal to 600mm wide Over 600mm wide
Lin.m Sq.m
9
11.1.0/1
Finish to Tread; Net width 300mm; Concrete background
Lin.m
12.1.0/1
Finish to Risers; Net width 150mm; Concrete background
Lin.m
Cement and Sand (1:6) screeded beds
1.1.1/2
1.2.1/2
Screeds, beds and toppings, 40mm thick in one coat less or equal to 600mm wide; Level and to falls only less or equal to 150 from horizontal; Concrete background
Lin.m
Over 600mm wide; Ditto
Sq.m
1.29: DECORATIONS Dulux or other equal and approved latex paint one coat; cement floated wall sandpapered smooth and one coat of primer on floated wall.
1.1.1. 1.2.1
Painting to general surfaces; less or equal to 300mm girth; internal Over 300mm girth; internal
Lin.m Sq.m
1.25: STAIRS, WALKWAYS AND BALUSTRADES Painted mild steel pipe balustrade 7.1.0
Balustrades; 900mm high comprising 20mm diameter vertical balusters; 40mm diameter sloping handrail; 6Nr. 20mm diameter intermediate rails; vertical balusters plugged and screwed to concrete with 6mm thick plate 100 X 100mm
Lin.m
To Collections
1.25: STAIRS, WALKWAYS AND BALUSTRADES (Cont'd) 8.1.0
Handrails; 900mm high comprising 20mm diameter vertical balusters; 40mm diameter sloping handrail; 6Nr. 20mm diameter intermediate rails; vertical balusters plugged and screwed to concrete with 6mm thick plate 100 X 100mm
10
Lin.m
To Collections
STAIRCASES CARRIED TO SUMARY
11
ROOF CONSTRUCTION AND COVERING 1.11: INSITU CONCRETE WORKS In situ Concrete Grade 25 Concrete
2.2.2/2
4.1.2/2
Horizontal Work Over 300mm thick; In structures; Reinforced less or equal to 5% Sloping over 150 ; less or equal to 300mm thick; In structures; Reinfored less or equal to 5%
Cu.m
Cu.m
Formwork Plain formwork 17.1.0
Sides and soffit of isolated beams; Rectangular
Sq.m
25.1.0
Soffit of sloping work; Sloping one way; Curved radius 520mm
Sq.m
28.2.0
Sloping top surfaces; over 150; Curved radius 520mm
Sq.m
14.1.0
Edges of horizontal less or equal to 500mm high: 150mm wide
Lin.m
Reinforcement
34.1.1*2
High Yield reinforcement Bars 12mm diameter; Straight and bent
Tonnes
34.1.1*2
Ditto over 12m long: length ……m
Tonnes
34.1.1*2
12mm diameter; Curved
Tonnes
34.1.1*2
10mm diameter; Links
Tonnes
12
To Collection
1.16: CARPENTRY Hardwood pressure impregnated with approved preservatives
1.1.1 1.1.3
Primary or Structural timbers 50 X 150mm; Rafters and associated timbers
Lin.m
100 X 150mm; Wall Plates
Lin.m
Ditto; Length over 6.00 in one continuous length
Lin.m
50 X 75mm; Purlins
Lin.m
1.1.2/9
Ditto; Length over 6.00 in one continuous length
Lin.m
1.1.5/9
50 X 150mm; Beams; Length over 6.00 in one continuous length
Lin.m
50 X 100mm; Strutting
Lin.m
1.1.3/9 1.1.2
1.1.8
1.17: SHEET ROOF COVERING Sheet Metals 0.7 gauge oven baked corrugated coloured Longspan Aluminium roofing sheet on Zed Purlins 1.2.3
4.1.2/1
Covering over 500mm wide; Sloping 300 Pitch; oven baked coloured
Sq.m
Boundary work; 200mm girth; Eaves; Horizontal
Lin.m
13
4.1.3/1
350mm girth; Ridges; Horizontal
Lin.m
4.1.5/1
350mm girth; Valleys; Sloping
Lin.m
4.1.6/1
350mm girth; Hips; Sloping
Lin.m
To Collection
1.15: STRUCTURAL METALWORK (Provisional)
1.1.1/4
1.1.2/4 1.2.2/3
1.2.2/2 5.2.1.
6.1.1/1
6.1.2/1
Framed members, framing and fabrication Length not exceeding 1.00m; weight less or equal to 25Kg/m; Bracings Weight 25 - 50Kg/m; Bracings
Tonnes Tonnes
Lengths 1.00 - 9.00m; Weight 25 - 50Kg/m; Rafters
Tonnes
Ditto; Beams
Tonnes
Allowance for fittings: Percentage Allowance: 20%; To framed members Cold Rolled Purlins, cladding rails and the like: Zed purlins bolted to 125 X 75 x 8mm 150mm long angle cleat welded to structural member; 150 X 50 x2mm Purlins 16mm diameter high tensile steel welded to Purlins:
14
Tonnes
Lin.m
Sag Rods 10.1.1
Lin.m
Holding down assemblies; 6mm thick base plate holding 4Nr. 24mm diameter one side threaded and other end fish tailed rag bolts complete with nuts and washers embedded in concrete.
Nr.
Berger paint or other equal and approved 15.3.1/2
Surface Treatment; painting; On site; One primer and two coats of red oxide
To Collections
INTERNAL AND EXTERNAL WALLS 1.11 INSITU CONCRETE WORKS In Situ Concrete Grade 25 Concrete in Superstructures Plain In Situ Concrete Reinforced 2.1.2/2
Horizontal work; Less or equal to 300mm thick;
15
Sq.m
In structures; Reinforced less or equal to 5%
Cu.m
Formwork - Plain formwork 17.1.0
Sides and soffit of isolated beams; Regular rectangular shape
Sq.m
Reinforcement 34.1.1*2
High yield steel bars; 12mm diameter; Straight and Bent
Tonnes
34.1.1*2
Ditto; Bars exceeding 12m long
Tonnes
1.14 MASONRY BRICK/BLOCK WALLING 225mm thick Hollow sandcrete blockwall bedded and jointed in cement mortar (1:6) and laid in stretcher bond 1.2.1
1.2.1
Walls overall thickness 225mm; Blockwork; Skin of hollow walls; laid in wall
Sq.m
Ditto 150mm ditto
Sq.m
INTERNAL AND EXTERNAL WALL CARRIED TO SUMMARY
16
WINDOW 1.23: WINDOWS SCREENS AND LIGHTS Nigalex or other equal and approved heavy gauge aluminium section two or three bays with net; factory glazed with tinted 4mm thick sheet glass complete with glazing beads and other accessories and ironmongery including screwing and plugging frames to blockwall and concretework to Architects drawings
1.1.0/2
Windows and window frames 1200 X 1200mm high
Nr.
1.1.0/2
1500 X 1500mm high
Nr.
1.1.0/2
600 X 600mm high
Nr.
1.26: METAL WORK Isolated Metal Member Burglar Bars comprising 50 X 25 X 2mm thick surround; 25 X 25 X 2mm thick vertical bars at 150mm intervals welded to surround bar and 25 X 25 X 2mm thick horizontal bars welded to surround bar and vertical at 300mm intervals including drilling holes in concrete or blockwork and fixing burglar bars to concrete with 12mm diameter high tensile hold bar driven in concrete or blockwork complete with painting in red oxide and finishing in gloss paint
5.1.1/1
Composite Items Ditto 1200 X 1200mm high; welded on 150mm long 12mm diameter bar drilled and driven into wall
Nr.
5.1.1/1
Ditto 1500 X 1500mm high; ditto
Nr.
5.1.1/1
Ditto 600 X 600m high; ditto
Nr.
17
WINDOWS CARRIED TO SUMMARY
DOORS Doors and Frames 44mm thick polished seasoned solid core fluch doors lipped on all edges with hardwood and faced on both sides with quality plywood complete with door lining architraves and all necessary ironmongery
1.1.1 1.1.1
Door Sets To fit opening size 900 X 2100mm high; blocwall Ditto 750 X 2100mm high; blockwall
Nr. Nr.
Purpose made swing doors constructed of hollowsteel sections and steel plates complete with frames and glazing comprising of 4mm thick clear sheet glass and beads including all necessary ironmongery
1.1.1 1.1.1
Door Sets To fit opening size 1800 X 2100mm high; blockwall Ditto 1200 X 2100mm high; blockwall
18
Nr. Nr.
DOORS CARRIED TO SUMMARY
WALL FINISHINGS 1.28: FLOOR WALL CEILING AND ROOF FINISHINGS Cement and sand (1:4) smooth rendering
7.2.0
Plastering to Walls 12mm thick; over 600mm wide
Sq.m
7.2.1
Less or equal to 600mm
Lin.m
7.2.0
over 600mm wide externally
Sq.m
7.2.1
Less or equal to 600mm externally
Lin.m
8.2.0
10.2.0 10.1.0 7.2.0
Plastering to isolated columns 12mm thick over 600mm wide
Sq.m
Plastering to isolated beams 12mm thick over 600mm wide
Sq.m
Less or equal to 600mm
Lin.m
Tiles to wall 10mm thick; over 600mm wide 1.29: DECORATIONS
19
Sq.m
Dulux or other equal and approved latex paint one coat; cement floated wall sandpapered smooth and one coat of primer on floated wall.
1.1.1
Painting to general surfaces; less or equal to 300mm girth; internal
Lin.m
1.2.1
Over 300mm girth; internal
Sq.m
1.1.2
less or equal to 300mm girth; external
Lin.m
1.2.2
Over 300mm girth; external
Sq.m
WALL FINISHING CARRIED TO SUMMARY
FLOOR FINISHINGS Cement and Sand screeded bed 1.1.1/1*2 Screeds, beds and topping 40mm thick in one coat; less or equal to 600mm wide; Level and to falls only less or equal to 150 from horizontal; Vitrified Tiles surface; Concrete background 1.2.1/1*2
Lin.m
Over 600mm wide; Level and to falls only less or equal to 150 from horizontal; Vitrified Tiles surface; concrete background 600 X 600 X 15mm thick Vitrified Tile Finish to floors, Vitrified Tiles 50mm thick overall
20
Sq.m
2.1.0 2.2.0 14.1.0/1
thickness; less or equal to 600mm wide
Lin.m
Over 600mm wide
Sq.m
Skirtings, net height 100mm; 15mm wide; Blockwall background
Lin.m
300 X 300 X 10mm thick Vitrified Tile
6.1.1.
6.2.1
Finish to floors, Vitrified Tiles 50mm thick overall thickness; less or equal to 600mm wide; Level and to falls only less or equal to 150 from horizontal. Over 600mm wide; ditto
Lin.m Sq.m
FLOOR FINISHING CARRIED TO SUMMARY
CEILING FINISHINGS 1.28: FLOOR WALL CEILING AND ROOF FINISHINGS Cement and Sand (1:4) rendering
21
9.1.0
Finishing to ceiling, plastering 12mm thick; over 600mm wide
Sq.m
600 X 600 X 20mm thick acoustic mineral fibre suspended ceiling in aluminium grid bearer 9.1.0
Finishing to ceiling, acoustic ceiling tiles 20mm thick; over 600wide
Sq.m
Dulux or other equal and approved latex paint one coat; cement floated wall sandpapered smooth and one coat of primer on floated wall. 1.2.1.
Painting to general surfaces; Over 300mm girth; internal
CEILING CARRIED TO SUMMARY
22
Sq.m
1.38: MECHANICAL SERVICES Rainwater Disposal System Mutunci or other equal and approved uPVC pipe 3.1.1
4.4.2
Pipework; Straight; 100mm diameter uPVC; socket and spigot joint; fixed to concrete with matching stainless steel bracket; Pipe Fittings; 100mm diameter pipe; socket and spigot joint Bend
Lin.m
Nr.
4.4.2
450 Bend
Nr.
5.8.1
Shoes
Nr.
5.7.1
Pipe ancillaries; Fulbora or other equal and approve outlet; uPVC, 100mm diameter, socket and spigot joint.
Nr.
Cold Water Supply System Rifeng or other equal and approved multi layer pipe 3.1.1/1
4.4.2
Pipework; Straight; 20mm diameter; jointed to manufacturers instructions; fixed in concrte or blockwork chases
Lin.m
Pipe Fittings; 20mm diameter pipe; jointed to manufacturer's instructions Bends Nr.
4.5.2
Tees
Nr.
4.2.2
20/12mm bushing
Nr.
5.1.1
Valve
Nr.
5.1.1
Pipe Fittings; 12mm diameter pipe; jointed to manufacturer's instructions; Angle Valve
23
Nr.
To Collection
MECHANICAL SERVICES (Cont'd) Cold Water Supply System (Cont'd) Tigre or other equal and approved uPVC pipe 3.1.1/1
4.4.2
Pipework; Straight; 25mm diameter uPVC; diced and screwed in joint with cement material and yarn rope; fixed to duct with matching stainless steel bracket. Pipe Fittings; 25mm diameter pipe; jointed as before described Bend
Lin.m
Nr.
5.1.1
Heavy Gauge Bronze cast Valves
Nr.
4.1.2
Union Connector
Nr.
4.2.2
Nipples
Nr.
Jointing to multi layered pipe
Nr.
Hot Water Supply System Rifeng or other equal and approved multi layer pipe 3.1.1/1
Pipework; Straight; 20mm diameter; jointed to manufacturers instructions; fixed in concrte or blockwork chases
Lin.m
Pipe Fittings; 20mm diameter pipe; jointed to manufacturer's
24
4.4.2
instructions Bends
Nr.
4.5.2
Tees
Nr.
4.2.2
20/12mm bushing
Nr.
5.1.1
Pipe Fittings; 12mm diameter pipe; jointed to manufacturer's instructions; Angle Valve
Nr.
To Collection
MECHANICAL SERVICES (Cont'd) Waste Disposal System Supply and install the following sanitary fitting manufactured by Twyford or other equal and approved
2.1.1/1
2.1.1/1
2.1.1/1
Terminal Equipment and fitting White vitreous China Water Closet Suite comprising Tank with flushing mechanism; Bowl plugged and screwed to floor with matching screws including seat and cover and pan connector. White Vitreous China Wash Hand Basin complete with chrome plated waste with chain and black rubber stay Chrome plated bib tap with hot and cold water discharge ability and uPVC white bottle trap White Vitreous enamel coated shower tray with
25
Nr.
Nr.
chrome plated waste and P trap; Chrome plated shower rose and pipe fixed to wall with clip plugged and screwed
Nr.
2.1.1/1
Toilet roll Holder plugged and screwed
Nr.
2.1.1/1
900mm long chrome plated towel rail pluigged and screwed
Nr.
450 X 600 X 10mm thick silver backed mirror
Nr.
2.1.1/1
Ariston or other equal and approved 2.1.1/1
Primary equipment; 50 liter water Heater hanged on wall
Nr.
To Collection
Waste Disposal (Cont'd) Mutunci or other equal and approved uPVC pipe 3.1.1./1
Pipework; Straight; 100mm diameter uPVC; socket and spigot joint; fixed to concrete with matching stainless steel bracket;
26
Lin.m
4.4.2
Pipe Fittings; 100mm diameter pipe; socket and spigot joint Bend
Nr.
4.8.2
Reducer Bend
Nr.
4.4.2
450 Bend
Nr.
4.5.2
Tees
Nr.
4.8.2 3.1.1/1
4.4.2
Reducer Tees
Nr.
Pipework; Straight; 50mm diameter uPVC; socket and spigot joint; fixed to concrete with matching stainless steel bracket; Pipe Fittings; 50mm diameter pipe; socket and spigot joint Bend
Lin.m
Nr.
4.8.2
450 Bend
Nr.
4.5.2
Tees
Nr.
To Collection
27
Fire Hose Reels Groundfos or other equal and approved 1.1.1./1
Primary equipment ; Fire fighting system; Fire pumps Nr. ABC or other equal and approved fire hose reel
2.1.1/1
Terminal Equipment and Fittings; Swing Arm Fire Hose Reels; Wall mount Cabinet type in red with 36m X 19mm fire fighting nozzle; high or low level on floors
Nr.
Heavy Gauge Gavanised iron pipe painted red with gloss paint 3.1.1/1
4.4.2
Pipework; Straight; 32mm diameter uPVC; diced and screwed in joint with cement material and yarn rope; fixed to duct with matching stainless steel bracket. Pipe Fittings; 32mm diameter pipe; jointed as before described Bend
Lin.m
Nr.
4.4.2
450 Bend
Nr.
4.8.2
Reducer Bend
Nr.
4.5.2
Tees
Nr.
5.1.1
Heavy Gauge Bronze cast Valves
Nr.
4.2.2
Union Connector
Nr.
4.2.2
Nipples
Nr.
28
To Collection
MECHANICAL SERVICES (Cont'd) Air conditioning Mutunci or other equal and approved uPVC pipe 3.1.1/1
Pipework; Straight; 75mm diameter uPVC; socket and spigot joint; Laid in chases
Lin.m
Pipe Fittings; 100mm diameter pipe; socket and spigot joint 4.4.2
450 Bend
Nr.
17.0.0
Testing
Item
18.0.0
Commisioning
Item
21.0.0
Drawing Preparation; Installation, Coordination, as installed, and record drawings
Item
To Collection
29
ELECTRICAL INSTALLATION Incoming Services Merlin Gerin, Schneider or other equal and approved
1.1.1/1
2.1.1/1
2.1.1/1 1.2.0
Primary Equipment Coloured oven baked metal clad Main Distribution Panel 800A T,P & N; One incoming 800A Rating; 4Nr 200A outgoing, 3Nr. 60A outgoing and 60A spare complete with all accessories; Low level in plant room
Nr.
Terminal equipment Coloured oven baked metal clad Low Voltage Distribution Panel 200A T P & N; One incoming 200A Rating; 6Nr. Outgoing and 1Nr. Spare rating 60A complete with MCCB, 200A T P & N Isolator Switch and other accessories; Low level on floors
Nr.
Change Over Switch 800A T P & N
Nr.
Offload and position of primary equipment
Nr.
30
1.3.0
Assembly of composite items of prmary equipment
Nr.
Nocaco or other equal and approved
3.1.1/1
Cables Armoured cable 240sq.mm 4 core copper pvc/swa/pvc jointed in running length to manufacturer's details; low level in plant room and on floor In trenches (Provisional)
Lin.m
3.1.1/1
In sleeves
Lin.m
3.1.1/1
In trunk (Provisional)
Lin.m
3.1.1/1 3.1.1/1
Armoured cable 70sq.mm 4 core copper pvc/swa/pvc jointed in running length to manufacturer's details; low level in plant room and on floor In trenches In sleeves
Lin.m Lin.m
To Collection
Incoming Services (Cont'd)
3.1.1/1
Cables (cont'd) Armoured cable 10sq.mm 4 core copper pvc/swa/pvc jointed in running length to manufacturer's details; low level in plant room and on floor In trenches
Lin.m
3.1.1/1
In sleeves
Lin.m
3.1.1/1
In trunk
Lin.m
Armoured cable 16sq.mm 4 core copper pvc/swa/pvc
31
3.1.1/1
jointed in running length to manufacturer's details; low level in plant room and on floor In trenches
Lin.m
3.1.1/1
In sleeves
Lin.m
3.1.1/1
In trunk
Lin.m
AEI Cables Limited or other equal and approved
6.0.1
6.0.1
Cable Terminations and Joints Outdoor type, 800A 240sq.mm 4 core bronze material armoured pvc/swa/pvc
Nr.
Outdoor type, 200A 70sq.mm 4 core bronze material armoured pvc/swa/pvc
Nr.
6.0.1
Indoor type ditto
Nr.
6.0.1
Outdoor type, 60A 10sq.mm 4 core bronze material armoured pvc/swa/pvc
Nr.
Indoor type, 60A 10sq.mm 4 core bronze material armoured pvc/swa/pvc
Nr.
Indoor type, 60A 16sq.mm 4 core bronze material armoured pvc/swa/pvc
Nr.
6.0.1
6.0.1
To Collection
Cable Containment
32
3.0.1/1
3.0.1/1
Galvanised sheet cable trunk with cover rectangular shape 250 X 75mm thick with three compartments jointed as may be directed by the Engineer plugged and screwed to wall; risers
Lin.m
Ditto; low level on floors
Lin.m
Final Circuits ABB or other equal and approved plugged and screwed to wall
1.1.1/1
1.1.1/1
Primary Equipment 60A 6 Ways T P & N metal clad Distribution Board with miniature circuit breakers and 60A ELCB 60A 4 Ways ditto
Nr. Nr.
Nocaco or other equal and approved single core wire drawn in 20mm diameter Mutunci or other equal and approved conduit pipe in chases
7.0.1
Final circuits PVC copper cable with 10A rating 1.5sq.mm size in 18Nr. Lighting points
Nr.
7.0.1
Ditto 22Nr. Ditto
Nr.
7.0.1
Ditto 11Nr. Ditto
Nr.
7.0.1
Ditto 25Nr. Ditto
Nr.
7.0.1
Ditto 21Nr. Ditto
Nr.
7.0.1
Ditto 17Nr. Ditto
Nr.
7.0.1
Ditto 19Nr. Ditto
Nr.
7.0.1
Ditto 15Nr. Ditto
Nr.
7.0.1
Ditto 14Nr. Ditto
Nr.
7.0.1
Ditto 20Nr. Ditto
Nr.
To Collection
33
Nocaco or other equal and approved single core wire drawn in 20mm diameter Mutunci or other equal and approved conduit pipe in chases
7.0.1
Final circuits PVC copper cable with 30A rating 2.5sq.mm size in ring circuit 11Nr. 13A Switched socket outlet
Nr.
7.0.1
13Nr. Ditto
Nr.
7.0.1
12Nr. Ditto
Nr.
7.0.1
9Nr. Ditto
Nr.
7.0.1
8Nr. Ditto
Nr.
7.0.1
7Nr. Ditto
Nr.
7.0.1
10Nr. Ditto
Nr.
7.0.1 7.0.1
PVC copper cable with 20A rating 4.0sq.mm size in 1Nr. 15A Switched socket outlet 1Nr. Water Heater
Nr. Nr.
ABB or other equal and approved accessories
2.1.1
Terminal Equipment 10A One Gang one Way Switch
Nr.
2.1.1
10A One Gang Two Way Switch
Nr.
2.1.1
10A Two Gang one Way Switch
Nr.
2.1.1
10A Two Gang Two Way Switch
Nr.
2.1.1
10A Three Gang one Way Switch
Nr.
34
2.1.1
10A Three Gang Two Way Switch
Nr.
2.1.1
20A Intermediate switch
Nr.
2.1.1
13A switched Socket Outlet
Nr.
2.1.1
13A Twin switched Socket Outlet
Nr.
To Collecton
Scolmore Ltd or other equal and approved Luminaires
2.1.1
Terminal Equipment 1 X 40W Screwneck ceiing mounted Lighting fitting with diffuser
Nr.
2.1.1
40W Recessed Fitting
Nr.
2.1.1
1 X 36W 1.2m fluorescent fitting with pristmatic transparent diffuser
Nr.
2.1.1
1 X 100W Bulkhead fitting with transparent diffuser
Nr.
2.1.1
60W Wall mounted lighting fitting with pristmatic diffuser.
Nr.
2.1.1
15A Socket Outlet
Nr.
2.1.1
SMC or other equal and approved 1200mm sweep ceiling Fan complete with regulator
Nr.
Fire Alarm system Gents or other equal and approved
1.1.1/1
Primary Equipment Vigilon Analogue 3 Loop Addressable Fire Alarm Panel High level on floors
35
Nr.
Nocaco or other equal and approved single core wire drawn in 20mm diameter Mutunci or other equal and approved conduit pipe in chases
7.0.1
Final circuits PVC copper cable with 10A rating 1.0sq.mm size in 87Nr. Points comprising 51Nr. Optical smoke detector, 18Nr. manual break call bells and 18Nr. Fire alarm call Bell
Nr.
Gents or other equal and approved
2.1.1 2.1.1 2.1.1
Terminal Equipment Addressable Optical Smoke Detector Manual Break Call Bell
Nr. Nr.
Addressable Fire Alarm Call Bell
Nr.
To Collection
Lightening and Earthing System Indelec or other equal and approved
12.0.1
12.0.1
12.0.1
Electrodes, Earth Rods Air Terminations, bars Prevectron 3 S40 Early Steamer Emission Air Terminal Lightening conductor
Nr.
Chromium plated copper M20 tapered threaded wall Air Rod lightening arrestor
Nr.
Highly conductive copper coated stainless steel pointed Copperbound Earth Rod 2400mm deep 17.2mm diameter in inspection house
Nr.
Indelec Lightening Protection system conductor
36
11.0.1/1
Tapes Tinned Copper tape conductors 25 X 3mm thick Roofs
Lin.m
11.0.1/1
Risers
Lin.m
11.0.1/1
Trenches
Lin.m
Nocaco or other equal and approved
5.0.1/1
Cables; 6 sq.mm PVC sheath single core copper cable low level in floors
Lin.m
5.0.1/1
In trenches
Lin.m
5.0.1/1
In trunks
Lin.m
15.0.0
Testing
Item
16.0.0
Commissioning
Item
19.0.0
Drawing Preparation; Installations, Coordination, as installed and record drawings
Item
Loose Ancillaries; Keys, tools, spares, chemicals
Item
21.1.0
To Collection
37
QUANTITES
ND
CRIPTIONS
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
View more...
Comments