PREPARATION OF BILLS OF QU

USING BESMM 4 AND

BILLS OF QUANTITES DESCRI

BY Mr. AYOOLA I. OGUNKANMI PUBLIC BUILDING DEPARTMENT FEDRAL CAPITAL DEVELOPMENT AUTHORITY

1

GARKI ABUJA

SUBSTRUCTURE 1.5: EXCAVATING AND FILLING 2.1.1 2.1.2 4.1.1

Removing Trees; (Provisional) Girth 500 - 1500mm; Filled with laterite Girth 1500 - 3000mm; Ditto

Nr. Nr.

Site Clearance; Clearing Site vegetation and other growth and dispose off site; entire site

Sq.m

5.2.0

Site Preparation; Remove topsoil 150mm deep

Sq.m

6.2.1

Excavation, commencing from stripped level; Foundation excavation; Not exceeding 2m deep

Cu.m

Extra Over Foundation excavation; (Provisional) Excavating in; below ground water level

Cu.m

7.1.3 7.2.1

9.1.1 9.2.0

11.1.2

11.2.2

Breaking up; Rock

Cu.m

Disposal Gound Water; 600mm below original ground level Excavated material off site

Item Cu.m

Filling obtained from excavated material Final thickness of filling not exceeding 500mm deep 500mm thick; Site, not more than 200mm around site, backfilling foundations; in layers average depth 250mm

Sq.m

Final thickness of filling exceeding 500mm deep 500mm thick; Site, not more than 200mm around site, backfilling foundations; in layers average depth 250mm

Sq.m

Graded Laterite

2

12.2.1

Imported Filling; Beds 50mm - 500mm deep 300mm thick; Level, to falls and cross falls

Cu.m

Granite or other equal and approved Hardcore football size 12.2.1

Imported Filling; Beds 50mm - 500mm deep 300mm thick; Level, to falls and cross falls

Cu.m

To Collecton

EXCAVATING AND FILLING (Cont'd) Approved quality 1mm thick damp proof membrane 16.2.1

Damp Proof Membrane; Over 500mm wide, 1mm thick; Horizontal

Sq.m

1.11: INSITU CONCRETE WORKS 1.1.2/1

2.1.1/1

2.2.2/2

5.1.1/1

Grade 30 Concrete Mass Concrete; 225mm thick; In trench filling; Poured on or against earth or unblinded hardcore

Cu.m

Weak Concrete (1:10 - graded sub base) Horizontal Work; less or equal to 300 thick; in blinding; poured on or against earth or unblinded hardcore

Cu.m

Grade 25 Concrete Horizontal Work Over 300mm thick; In structures; Reinforced less or equal to 5%.

Cu.m

Vertical Work; less or equal to 300mm thick; in structures; Reinforced 5%

Cu.m

3

Formwork

13.1.0 13.2.0

Plain formwork Sides of foundations and bases; less or equal to 500mm high: 450mm wide over 500mm high

Lin.m Lin.m

14.1.0

Edges of horizontal; less or equal to 500mm high: 150mm

Lin.m

20.1.0

Sides of isolated Columns 188Nr.; Regular rectangular shape

Sq.m

Reinforcement

34.1.2

High yield steel bars 20mm diameter; Bent;

Tonnes

34.1.2

16mm diameter; Bent;

Tonnes

34.1.2

10mm diameter; Links

Tonnes

37.1.0

Mesh; 4.52kg/sq.m Ref. A152 minimum laps 150mm

Sq.m

To Collection

1.14: MASONRY Brick/Block Walling Hollow sandcrete blockwall beded and jointed in cement and sand (1:6)

1.2.1/1

Walls; 225mm thick; blockwork; skin of hollow walls; laid in stretcher bond Cement and Sand (1:1)

4

Sq.m

16.1.3

Damp Proof Course less or equal 300mm wide; 50mm thick; Horizontal

Lin.m

1.28: FLOOR WALL CEILING AND ROOF FINISHINGS Cement and sand (1:4) smooth rendering 7.1.0

Plastering to Walls 12mm thick; Less or equal to 600mm

Lin.m

1.29: DECORATIONS Dulux or other equal and approved latex paint one coat; cement floated wall sandpapered smooth and one coat of primer on floated wall. 1.2.2

Painting to general surfaces; Over 300mm girth; external

To Collection

SUBSTRUCTURE CARRIED TO SUMMARY

FRAMES 1.11: INSITU CONCRETE WORKS 5

Sq.m

Insitu Concrete Grade 25 Concrete 5.1.1/1

Vertical Work; less or equal to 300mm thick; In structures Reinforced less or equal to 5%

Cu.m

Formwork Plain Formwork 20.1.0

Sides of Isolated Columns, 34Nr.; rectangular

Sq.m

Reinforcement

34.1.1*2

High yield steel bars; 20mm diameter; Straight and Bent

Tonnes

34.1.1*2

16mm ditto

Tonnes

34.1.1*2

10mm diameter; Links

Tonnes

FRAMES CARRIED TO SUMMARY

6

UPPER FLOORS 1.11: INSITU CONCRETE WORKS Insitu Concrete Grade 25 Concrete

2.1.2/2

2.2.2/2

Horizontal Work; less or equal to 300mm thick; In structures; Reinforced less or equal to 5% Over 300mm thick ditto

Cu.m Cu.m

Formwork Plain Formwork 14.1.0

15.1.1

18.1.0

Edges of Horizontal; Width less or equal to 500mm: 150mm wide

Lin.m

Soffits of Horizontal Work; For concrete less or equal to 300mm thick; Propping less or equal to 3m high

Sq.m

Sides and soffit of attached Beams; Rectangular

Sq.m

Reinforcement

34.1.1*2

High yield steel bars; 20mm diameter; Straight and Bent

Tonnes

34.1.1*2

16mm ditto

Tonnes

34.1.1*2

12mm ditto

Tonnes

34.1.1*2

10mm diameter; Links

Tonnes

7

UPPER FLOORS CARRIED TO SUMMARY

STAIRCASES 1.11 INSITU CONCRETE WORKS PLAIN IN SITU CONCRETE REINFORCED Grade 25 Concrete 2.1.2

4.2.3/2

Horizontal Works; less or equal to 300mm thick in Structures

Cu.m

Sloping Works over 150 ; over 300mm thick; in staircases; Reinforced less or equal to 5%

Cu.m

FORMWORK Plain formwork 14.1.0

Edges of horizontal; less or equal to 500mm high: 150mm wide

Lin.m

Soffits of horizontal works; for concrete less or equal to 300 thick; propping less or equal to 3m high

Sq.m

25.1.0

Soffit of sloping work; sloping one way

Sq.m

26.1.0

Staircase strings and the like; maximum width 380mm

Lin.m

27.1.0

Staircase Risers and the like; Vertical 150mm wide

Lin.m

15.1.1

8

REINFORCEMENT

34.1.1*2

High yield steel bars 16mm diameter straight and bent

Tonnes

34.1.1*2

12mm ditto

Tonnes

34.1.1*2

10mm diameter; Links

Tonnes

TO COLLECTION

STAIRCASES (Contd) 1.28: FLOOR WALL CEILING AND ROOF FINISHINGS Cement and sand (1:4) smooth rendering

7.2.0 7.1.0

Plastering to Walls 12mm thick; over 600mm wide

Sq.m

Less or equal to 600mm

Lin.m

600 X 600 X 15mm thick Vitrified Tile

2.1.0 2.2.0

Finish to floors, Vitrified Tiles 50mm thick overall thickness; less or equal to 600mm wide Over 600mm wide

Lin.m Sq.m

9

11.1.0/1

Finish to Tread; Net width 300mm; Concrete background

Lin.m

12.1.0/1

Finish to Risers; Net width 150mm; Concrete background

Lin.m

Cement and Sand (1:6) screeded beds

1.1.1/2

1.2.1/2

Screeds, beds and toppings, 40mm thick in one coat less or equal to 600mm wide; Level and to falls only less or equal to 150 from horizontal; Concrete background

Lin.m

Over 600mm wide; Ditto

Sq.m

1.29: DECORATIONS Dulux or other equal and approved latex paint one coat; cement floated wall sandpapered smooth and one coat of primer on floated wall.

1.1.1. 1.2.1

Painting to general surfaces; less or equal to 300mm girth; internal Over 300mm girth; internal

Lin.m Sq.m

1.25: STAIRS, WALKWAYS AND BALUSTRADES Painted mild steel pipe balustrade 7.1.0

Balustrades; 900mm high comprising 20mm diameter vertical balusters; 40mm diameter sloping handrail; 6Nr. 20mm diameter intermediate rails; vertical balusters plugged and screwed to concrete with 6mm thick plate 100 X 100mm

Lin.m

To Collections

1.25: STAIRS, WALKWAYS AND BALUSTRADES (Cont'd) 8.1.0

Handrails; 900mm high comprising 20mm diameter vertical balusters; 40mm diameter sloping handrail; 6Nr. 20mm diameter intermediate rails; vertical balusters plugged and screwed to concrete with 6mm thick plate 100 X 100mm

10

Lin.m

To Collections

STAIRCASES CARRIED TO SUMARY

11

ROOF CONSTRUCTION AND COVERING 1.11: INSITU CONCRETE WORKS In situ Concrete Grade 25 Concrete

2.2.2/2

4.1.2/2

Horizontal Work Over 300mm thick; In structures; Reinforced less or equal to 5% Sloping over 150 ; less or equal to 300mm thick; In structures; Reinfored less or equal to 5%

Cu.m

Cu.m

Formwork Plain formwork 17.1.0

Sides and soffit of isolated beams; Rectangular

Sq.m

25.1.0

Soffit of sloping work; Sloping one way; Curved radius 520mm

Sq.m

28.2.0

Sloping top surfaces; over 150; Curved radius 520mm

Sq.m

14.1.0

Edges of horizontal less or equal to 500mm high: 150mm wide

Lin.m

Reinforcement

34.1.1*2

High Yield reinforcement Bars 12mm diameter; Straight and bent

Tonnes

34.1.1*2

Ditto over 12m long: length ……m

Tonnes

34.1.1*2

12mm diameter; Curved

Tonnes

34.1.1*2

10mm diameter; Links

Tonnes

12

To Collection

1.16: CARPENTRY Hardwood pressure impregnated with approved preservatives

1.1.1 1.1.3

Primary or Structural timbers 50 X 150mm; Rafters and associated timbers

Lin.m

100 X 150mm; Wall Plates

Lin.m

Ditto; Length over 6.00 in one continuous length

Lin.m

50 X 75mm; Purlins

Lin.m

1.1.2/9

Ditto; Length over 6.00 in one continuous length

Lin.m

1.1.5/9

50 X 150mm; Beams; Length over 6.00 in one continuous length

Lin.m

50 X 100mm; Strutting

Lin.m

1.1.3/9 1.1.2

1.1.8

1.17: SHEET ROOF COVERING Sheet Metals 0.7 gauge oven baked corrugated coloured Longspan Aluminium roofing sheet on Zed Purlins 1.2.3

4.1.2/1

Covering over 500mm wide; Sloping 300 Pitch; oven baked coloured

Sq.m

Boundary work; 200mm girth; Eaves; Horizontal

Lin.m

13

4.1.3/1

350mm girth; Ridges; Horizontal

Lin.m

4.1.5/1

350mm girth; Valleys; Sloping

Lin.m

4.1.6/1

350mm girth; Hips; Sloping

Lin.m

To Collection

1.15: STRUCTURAL METALWORK (Provisional)

1.1.1/4

1.1.2/4 1.2.2/3

1.2.2/2 5.2.1.

6.1.1/1

6.1.2/1

Framed members, framing and fabrication Length not exceeding 1.00m; weight less or equal to 25Kg/m; Bracings Weight 25 - 50Kg/m; Bracings

Tonnes Tonnes

Lengths 1.00 - 9.00m; Weight 25 - 50Kg/m; Rafters

Tonnes

Ditto; Beams

Tonnes

Allowance for fittings: Percentage Allowance: 20%; To framed members Cold Rolled Purlins, cladding rails and the like: Zed purlins bolted to 125 X 75 x 8mm 150mm long angle cleat welded to structural member; 150 X 50 x2mm Purlins 16mm diameter high tensile steel welded to Purlins:

14

Tonnes

Lin.m

Sag Rods 10.1.1

Lin.m

Holding down assemblies; 6mm thick base plate holding 4Nr. 24mm diameter one side threaded and other end fish tailed rag bolts complete with nuts and washers embedded in concrete.

Nr.

Berger paint or other equal and approved 15.3.1/2

Surface Treatment; painting; On site; One primer and two coats of red oxide

To Collections

INTERNAL AND EXTERNAL WALLS 1.11 INSITU CONCRETE WORKS In Situ Concrete Grade 25 Concrete in Superstructures Plain In Situ Concrete Reinforced 2.1.2/2

Horizontal work; Less or equal to 300mm thick;

15

Sq.m

In structures; Reinforced less or equal to 5%

Cu.m

Formwork - Plain formwork 17.1.0

Sides and soffit of isolated beams; Regular rectangular shape

Sq.m

Reinforcement 34.1.1*2

High yield steel bars; 12mm diameter; Straight and Bent

Tonnes

34.1.1*2

Ditto; Bars exceeding 12m long

Tonnes

1.14 MASONRY BRICK/BLOCK WALLING 225mm thick Hollow sandcrete blockwall bedded and jointed in cement mortar (1:6) and laid in stretcher bond 1.2.1

1.2.1

Walls overall thickness 225mm; Blockwork; Skin of hollow walls; laid in wall

Sq.m

Ditto 150mm ditto

Sq.m

INTERNAL AND EXTERNAL WALL CARRIED TO SUMMARY

16

WINDOW 1.23: WINDOWS SCREENS AND LIGHTS Nigalex or other equal and approved heavy gauge aluminium section two or three bays with net; factory glazed with tinted 4mm thick sheet glass complete with glazing beads and other accessories and ironmongery including screwing and plugging frames to blockwall and concretework to Architects drawings

1.1.0/2

Windows and window frames 1200 X 1200mm high

Nr.

1.1.0/2

1500 X 1500mm high

Nr.

1.1.0/2

600 X 600mm high

Nr.

1.26: METAL WORK Isolated Metal Member Burglar Bars comprising 50 X 25 X 2mm thick surround; 25 X 25 X 2mm thick vertical bars at 150mm intervals welded to surround bar and 25 X 25 X 2mm thick horizontal bars welded to surround bar and vertical at 300mm intervals including drilling holes in concrete or blockwork and fixing burglar bars to concrete with 12mm diameter high tensile hold bar driven in concrete or blockwork complete with painting in red oxide and finishing in gloss paint

5.1.1/1

Composite Items Ditto 1200 X 1200mm high; welded on 150mm long 12mm diameter bar drilled and driven into wall

Nr.

5.1.1/1

Ditto 1500 X 1500mm high; ditto

Nr.

5.1.1/1

Ditto 600 X 600m high; ditto

Nr.

17

WINDOWS CARRIED TO SUMMARY

DOORS Doors and Frames 44mm thick polished seasoned solid core fluch doors lipped on all edges with hardwood and faced on both sides with quality plywood complete with door lining architraves and all necessary ironmongery

1.1.1 1.1.1

Door Sets To fit opening size 900 X 2100mm high; blocwall Ditto 750 X 2100mm high; blockwall

Nr. Nr.

Purpose made swing doors constructed of hollowsteel sections and steel plates complete with frames and glazing comprising of 4mm thick clear sheet glass and beads including all necessary ironmongery

1.1.1 1.1.1

Door Sets To fit opening size 1800 X 2100mm high; blockwall Ditto 1200 X 2100mm high; blockwall

18

Nr. Nr.

DOORS CARRIED TO SUMMARY

WALL FINISHINGS 1.28: FLOOR WALL CEILING AND ROOF FINISHINGS Cement and sand (1:4) smooth rendering

7.2.0

Plastering to Walls 12mm thick; over 600mm wide

Sq.m

7.2.1

Less or equal to 600mm

Lin.m

7.2.0

over 600mm wide externally

Sq.m

7.2.1

Less or equal to 600mm externally

Lin.m

8.2.0

10.2.0 10.1.0 7.2.0

Plastering to isolated columns 12mm thick over 600mm wide

Sq.m

Plastering to isolated beams 12mm thick over 600mm wide

Sq.m

Less or equal to 600mm

Lin.m

Tiles to wall 10mm thick; over 600mm wide 1.29: DECORATIONS

19

Sq.m

Dulux or other equal and approved latex paint one coat; cement floated wall sandpapered smooth and one coat of primer on floated wall.

1.1.1

Painting to general surfaces; less or equal to 300mm girth; internal

Lin.m

1.2.1

Over 300mm girth; internal

Sq.m

1.1.2

less or equal to 300mm girth; external

Lin.m

1.2.2

Over 300mm girth; external

Sq.m

WALL FINISHING CARRIED TO SUMMARY

FLOOR FINISHINGS Cement and Sand screeded bed 1.1.1/1*2 Screeds, beds and topping 40mm thick in one coat; less or equal to 600mm wide; Level and to falls only less or equal to 150 from horizontal; Vitrified Tiles surface; Concrete background 1.2.1/1*2

Lin.m

Over 600mm wide; Level and to falls only less or equal to 150 from horizontal; Vitrified Tiles surface; concrete background 600 X 600 X 15mm thick Vitrified Tile Finish to floors, Vitrified Tiles 50mm thick overall

20

Sq.m

2.1.0 2.2.0 14.1.0/1

thickness; less or equal to 600mm wide

Lin.m

Over 600mm wide

Sq.m

Skirtings, net height 100mm; 15mm wide; Blockwall background

Lin.m

300 X 300 X 10mm thick Vitrified Tile

6.1.1.

6.2.1

Finish to floors, Vitrified Tiles 50mm thick overall thickness; less or equal to 600mm wide; Level and to falls only less or equal to 150 from horizontal. Over 600mm wide; ditto

Lin.m Sq.m

FLOOR FINISHING CARRIED TO SUMMARY

CEILING FINISHINGS 1.28: FLOOR WALL CEILING AND ROOF FINISHINGS Cement and Sand (1:4) rendering

21

9.1.0

Finishing to ceiling, plastering 12mm thick; over 600mm wide

Sq.m

600 X 600 X 20mm thick acoustic mineral fibre suspended ceiling in aluminium grid bearer 9.1.0

Finishing to ceiling, acoustic ceiling tiles 20mm thick; over 600wide

Sq.m

Dulux or other equal and approved latex paint one coat; cement floated wall sandpapered smooth and one coat of primer on floated wall. 1.2.1.

Painting to general surfaces; Over 300mm girth; internal

CEILING CARRIED TO SUMMARY

22

Sq.m

1.38: MECHANICAL SERVICES Rainwater Disposal System Mutunci or other equal and approved uPVC pipe 3.1.1

4.4.2

Pipework; Straight; 100mm diameter uPVC; socket and spigot joint; fixed to concrete with matching stainless steel bracket; Pipe Fittings; 100mm diameter pipe; socket and spigot joint Bend

Lin.m

Nr.

4.4.2

450 Bend

Nr.

5.8.1

Shoes

Nr.

5.7.1

Pipe ancillaries; Fulbora or other equal and approve outlet; uPVC, 100mm diameter, socket and spigot joint.

Nr.

Cold Water Supply System Rifeng or other equal and approved multi layer pipe 3.1.1/1

4.4.2

Pipework; Straight; 20mm diameter; jointed to manufacturers instructions; fixed in concrte or blockwork chases

Lin.m

Pipe Fittings; 20mm diameter pipe; jointed to manufacturer's instructions Bends Nr.

4.5.2

Tees

Nr.

4.2.2

20/12mm bushing

Nr.

5.1.1

Valve

Nr.

5.1.1

Pipe Fittings; 12mm diameter pipe; jointed to manufacturer's instructions; Angle Valve

23

Nr.

To Collection

MECHANICAL SERVICES (Cont'd) Cold Water Supply System (Cont'd) Tigre or other equal and approved uPVC pipe 3.1.1/1

4.4.2

Pipework; Straight; 25mm diameter uPVC; diced and screwed in joint with cement material and yarn rope; fixed to duct with matching stainless steel bracket. Pipe Fittings; 25mm diameter pipe; jointed as before described Bend

Lin.m

Nr.

5.1.1

Heavy Gauge Bronze cast Valves

Nr.

4.1.2

Union Connector

Nr.

4.2.2

Nipples

Nr.

Jointing to multi layered pipe

Nr.

Hot Water Supply System Rifeng or other equal and approved multi layer pipe 3.1.1/1

Pipework; Straight; 20mm diameter; jointed to manufacturers instructions; fixed in concrte or blockwork chases

Lin.m

Pipe Fittings; 20mm diameter pipe; jointed to manufacturer's

24

4.4.2

instructions Bends

Nr.

4.5.2

Tees

Nr.

4.2.2

20/12mm bushing

Nr.

5.1.1

Pipe Fittings; 12mm diameter pipe; jointed to manufacturer's instructions; Angle Valve

Nr.

To Collection

MECHANICAL SERVICES (Cont'd) Waste Disposal System Supply and install the following sanitary fitting manufactured by Twyford or other equal and approved

2.1.1/1

2.1.1/1

2.1.1/1

Terminal Equipment and fitting White vitreous China Water Closet Suite comprising Tank with flushing mechanism; Bowl plugged and screwed to floor with matching screws including seat and cover and pan connector. White Vitreous China Wash Hand Basin complete with chrome plated waste with chain and black rubber stay Chrome plated bib tap with hot and cold water discharge ability and uPVC white bottle trap White Vitreous enamel coated shower tray with

25

Nr.

Nr.

chrome plated waste and P trap; Chrome plated shower rose and pipe fixed to wall with clip plugged and screwed

Nr.

2.1.1/1

Toilet roll Holder plugged and screwed

Nr.

2.1.1/1

900mm long chrome plated towel rail pluigged and screwed

Nr.

450 X 600 X 10mm thick silver backed mirror

Nr.

2.1.1/1

Ariston or other equal and approved 2.1.1/1

Primary equipment; 50 liter water Heater hanged on wall

Nr.

To Collection

Waste Disposal (Cont'd) Mutunci or other equal and approved uPVC pipe 3.1.1./1

Pipework; Straight; 100mm diameter uPVC; socket and spigot joint; fixed to concrete with matching stainless steel bracket;

26

Lin.m

4.4.2

Pipe Fittings; 100mm diameter pipe; socket and spigot joint Bend

Nr.

4.8.2

Reducer Bend

Nr.

4.4.2

450 Bend

Nr.

4.5.2

Tees

Nr.

4.8.2 3.1.1/1

4.4.2

Reducer Tees

Nr.

Pipework; Straight; 50mm diameter uPVC; socket and spigot joint; fixed to concrete with matching stainless steel bracket; Pipe Fittings; 50mm diameter pipe; socket and spigot joint Bend

Lin.m

Nr.

4.8.2

450 Bend

Nr.

4.5.2

Tees

Nr.

To Collection

27

Fire Hose Reels Groundfos or other equal and approved 1.1.1./1

Primary equipment ; Fire fighting system; Fire pumps Nr. ABC or other equal and approved fire hose reel

2.1.1/1

Terminal Equipment and Fittings; Swing Arm Fire Hose Reels; Wall mount Cabinet type in red with 36m X 19mm fire fighting nozzle; high or low level on floors

Nr.

Heavy Gauge Gavanised iron pipe painted red with gloss paint 3.1.1/1

4.4.2

Pipework; Straight; 32mm diameter uPVC; diced and screwed in joint with cement material and yarn rope; fixed to duct with matching stainless steel bracket. Pipe Fittings; 32mm diameter pipe; jointed as before described Bend

Lin.m

Nr.

4.4.2

450 Bend

Nr.

4.8.2

Reducer Bend

Nr.

4.5.2

Tees

Nr.

5.1.1

Heavy Gauge Bronze cast Valves

Nr.

4.2.2

Union Connector

Nr.

4.2.2

Nipples

Nr.

28

To Collection

MECHANICAL SERVICES (Cont'd) Air conditioning Mutunci or other equal and approved uPVC pipe 3.1.1/1

Pipework; Straight; 75mm diameter uPVC; socket and spigot joint; Laid in chases

Lin.m

Pipe Fittings; 100mm diameter pipe; socket and spigot joint 4.4.2

450 Bend

Nr.

17.0.0

Testing

Item

18.0.0

Commisioning

Item

21.0.0

Drawing Preparation; Installation, Coordination, as installed, and record drawings

Item

To Collection

29

ELECTRICAL INSTALLATION Incoming Services Merlin Gerin, Schneider or other equal and approved

1.1.1/1

2.1.1/1

2.1.1/1 1.2.0

Primary Equipment Coloured oven baked metal clad Main Distribution Panel 800A T,P & N; One incoming 800A Rating; 4Nr 200A outgoing, 3Nr. 60A outgoing and 60A spare complete with all accessories; Low level in plant room

Nr.

Terminal equipment Coloured oven baked metal clad Low Voltage Distribution Panel 200A T P & N; One incoming 200A Rating; 6Nr. Outgoing and 1Nr. Spare rating 60A complete with MCCB, 200A T P & N Isolator Switch and other accessories; Low level on floors

Nr.

Change Over Switch 800A T P & N

Nr.

Offload and position of primary equipment

Nr.

30

1.3.0

Assembly of composite items of prmary equipment

Nr.

Nocaco or other equal and approved

3.1.1/1

Cables Armoured cable 240sq.mm 4 core copper pvc/swa/pvc jointed in running length to manufacturer's details; low level in plant room and on floor In trenches (Provisional)

Lin.m

3.1.1/1

In sleeves

Lin.m

3.1.1/1

In trunk (Provisional)

Lin.m

3.1.1/1 3.1.1/1

Armoured cable 70sq.mm 4 core copper pvc/swa/pvc jointed in running length to manufacturer's details; low level in plant room and on floor In trenches In sleeves

Lin.m Lin.m

To Collection

Incoming Services (Cont'd)

3.1.1/1

Cables (cont'd) Armoured cable 10sq.mm 4 core copper pvc/swa/pvc jointed in running length to manufacturer's details; low level in plant room and on floor In trenches

Lin.m

3.1.1/1

In sleeves

Lin.m

3.1.1/1

In trunk

Lin.m

Armoured cable 16sq.mm 4 core copper pvc/swa/pvc

31

3.1.1/1

jointed in running length to manufacturer's details; low level in plant room and on floor In trenches

Lin.m

3.1.1/1

In sleeves

Lin.m

3.1.1/1

In trunk

Lin.m

AEI Cables Limited or other equal and approved

6.0.1

6.0.1

Cable Terminations and Joints Outdoor type, 800A 240sq.mm 4 core bronze material armoured pvc/swa/pvc

Nr.

Outdoor type, 200A 70sq.mm 4 core bronze material armoured pvc/swa/pvc

Nr.

6.0.1

Indoor type ditto

Nr.

6.0.1

Outdoor type, 60A 10sq.mm 4 core bronze material armoured pvc/swa/pvc

Nr.

Indoor type, 60A 10sq.mm 4 core bronze material armoured pvc/swa/pvc

Nr.

Indoor type, 60A 16sq.mm 4 core bronze material armoured pvc/swa/pvc

Nr.

6.0.1

6.0.1

To Collection

Cable Containment

32

3.0.1/1

3.0.1/1

Galvanised sheet cable trunk with cover rectangular shape 250 X 75mm thick with three compartments jointed as may be directed by the Engineer plugged and screwed to wall; risers

Lin.m

Ditto; low level on floors

Lin.m

Final Circuits ABB or other equal and approved plugged and screwed to wall

1.1.1/1

1.1.1/1

Primary Equipment 60A 6 Ways T P & N metal clad Distribution Board with miniature circuit breakers and 60A ELCB 60A 4 Ways ditto

Nr. Nr.

Nocaco or other equal and approved single core wire drawn in 20mm diameter Mutunci or other equal and approved conduit pipe in chases

7.0.1

Final circuits PVC copper cable with 10A rating 1.5sq.mm size in 18Nr. Lighting points

Nr.

7.0.1

Ditto 22Nr. Ditto

Nr.

7.0.1

Ditto 11Nr. Ditto

Nr.

7.0.1

Ditto 25Nr. Ditto

Nr.

7.0.1

Ditto 21Nr. Ditto

Nr.

7.0.1

Ditto 17Nr. Ditto

Nr.

7.0.1

Ditto 19Nr. Ditto

Nr.

7.0.1

Ditto 15Nr. Ditto

Nr.

7.0.1

Ditto 14Nr. Ditto

Nr.

7.0.1

Ditto 20Nr. Ditto

Nr.

To Collection

33

Nocaco or other equal and approved single core wire drawn in 20mm diameter Mutunci or other equal and approved conduit pipe in chases

7.0.1

Final circuits PVC copper cable with 30A rating 2.5sq.mm size in ring circuit 11Nr. 13A Switched socket outlet

Nr.

7.0.1

13Nr. Ditto

Nr.

7.0.1

12Nr. Ditto

Nr.

7.0.1

9Nr. Ditto

Nr.

7.0.1

8Nr. Ditto

Nr.

7.0.1

7Nr. Ditto

Nr.

7.0.1

10Nr. Ditto

Nr.

7.0.1 7.0.1

PVC copper cable with 20A rating 4.0sq.mm size in 1Nr. 15A Switched socket outlet 1Nr. Water Heater

Nr. Nr.

ABB or other equal and approved accessories

2.1.1

Terminal Equipment 10A One Gang one Way Switch

Nr.

2.1.1

10A One Gang Two Way Switch

Nr.

2.1.1

10A Two Gang one Way Switch

Nr.

2.1.1

10A Two Gang Two Way Switch

Nr.

2.1.1

10A Three Gang one Way Switch

Nr.

34

2.1.1

10A Three Gang Two Way Switch

Nr.

2.1.1

20A Intermediate switch

Nr.

2.1.1

13A switched Socket Outlet

Nr.

2.1.1

13A Twin switched Socket Outlet

Nr.

To Collecton

Scolmore Ltd or other equal and approved Luminaires

2.1.1

Terminal Equipment 1 X 40W Screwneck ceiing mounted Lighting fitting with diffuser

Nr.

2.1.1

40W Recessed Fitting

Nr.

2.1.1

1 X 36W 1.2m fluorescent fitting with pristmatic transparent diffuser

Nr.

2.1.1

1 X 100W Bulkhead fitting with transparent diffuser

Nr.

2.1.1

60W Wall mounted lighting fitting with pristmatic diffuser.

Nr.

2.1.1

15A Socket Outlet

Nr.

2.1.1

SMC or other equal and approved 1200mm sweep ceiling Fan complete with regulator

Nr.

Fire Alarm system Gents or other equal and approved

1.1.1/1

Primary Equipment Vigilon Analogue 3 Loop Addressable Fire Alarm Panel High level on floors

35

Nr.

Nocaco or other equal and approved single core wire drawn in 20mm diameter Mutunci or other equal and approved conduit pipe in chases

7.0.1

Final circuits PVC copper cable with 10A rating 1.0sq.mm size in 87Nr. Points comprising 51Nr. Optical smoke detector, 18Nr. manual break call bells and 18Nr. Fire alarm call Bell

Nr.

Gents or other equal and approved

2.1.1 2.1.1 2.1.1

Terminal Equipment Addressable Optical Smoke Detector Manual Break Call Bell

Nr. Nr.

Addressable Fire Alarm Call Bell

Nr.

To Collection

Lightening and Earthing System Indelec or other equal and approved

12.0.1

12.0.1

12.0.1

Electrodes, Earth Rods Air Terminations, bars Prevectron 3 S40 Early Steamer Emission Air Terminal Lightening conductor

Nr.

Chromium plated copper M20 tapered threaded wall Air Rod lightening arrestor

Nr.

Highly conductive copper coated stainless steel pointed Copperbound Earth Rod 2400mm deep 17.2mm diameter in inspection house

Nr.

Indelec Lightening Protection system conductor

36

11.0.1/1

Tapes Tinned Copper tape conductors 25 X 3mm thick Roofs

Lin.m

11.0.1/1

Risers

Lin.m

11.0.1/1

Trenches

Lin.m

Nocaco or other equal and approved

5.0.1/1

Cables; 6 sq.mm PVC sheath single core copper cable low level in floors

Lin.m

5.0.1/1

In trenches

Lin.m

5.0.1/1

In trunks

Lin.m

15.0.0

Testing

Item

16.0.0

Commissioning

Item

19.0.0

Drawing Preparation; Installations, Coordination, as installed and record drawings

Item

Loose Ancillaries; Keys, tools, spares, chemicals

Item

21.1.0

To Collection

37

QUANTITES

ND

CRIPTIONS

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61

62

63

64

65

66

67

68

69

70

71

72

73

74

View more...

Comments

Copyright ©2017 KUPDF Inc.
SUPPORT KUPDF