Axial Flow Fans Fan s Issue 6
1
Axial Flow Fans
Axial Flow Fans Axial Flow Fans
Content 4– 5 6 – 13 14 – 17 18 – 21 22 – 23 24 – 43 44 – 45 46 – 47
2
Technical Technical data Curves Dimensions Specifications Samples Accessories Description Notes
Axial Flow Fans
Axial Flow Fans High Performance - Axial Flow Fans AQA 61-0315/-0630 Square wall mounting plate incorporating an inlet ring of galvanised sheet steel and painted. (light grey) Plastic impeller bolted to the rotor of the i ntegral motor, motor, Connecting cable and terminal box supplied loose Inlet guard fitted conforming to DIN EN 294. Low noise, maintenance free, ready to connect
Application: General ventilation, Cooling industry, Farming and glass house ventilation
High Performance - Axial Flow Fans AWA 11-0200/-0300 11-0200/-0300 Wall mounting ring incorporating an inlet cone of painted sheet steel. Impeller made from galvanised sheet steel shrink-fitted onto the rotor of the integral motor, Connection cable supplied loose Inlet guard fitted conforming to DIN EN 294. Low noise, maintenance free, ready to connect
Application: General ventilation, Cooling industry, Farming and glass house ventilation
AWA 61-0315/-0630 61-0315/-0630 Wall mounting ring incorporating an inlet cone of galvanised sheet steel and painted. (light grey) Plastic impeller bolted to the rotor of the i ntegral motor, motor, Connecting cable and terminal box supplied loose Inlet guard fitted conforming to DIN EN 294. Low noise, maintenance free, ready to connect
Application: General ventilation, Cooling industry, Farming and glass house ventilation
High Performance - Axial Flow Fans ARA 61-0315/-0630 Duct mounted casing with connecting flanges on both sides, made from sheet steel and powder coated Plastic impeller bolted to the rotor of the i ntegral motor, motor, Low noise, maintenance free, ready for connection with terminal box fitted on fan casing
Application: General ventilation, Cooling industry, Farming and glass house ventilation
ARA 62-0315/-0630 Duct mounted for flush mounting in long casing design, made from sheet steel and powder coated Plastic impeller bolted to the rotor of the i ntegral motor, motor, Low noise, maintenance free, ready for connection with terminal box fitted on fan casing
Application: General ventilation, Cooling industry, Farming and glass house ventilation
High Performance - Axial Flow Fans ATA ATA 61-0315/-0630 61-0315/-0630 Technical Technical design as for AWA and AQA but without wall ring, suitable to be integrated into units. Self supporting inlet guard fitted conforming to DIN EN 294. Low noise, maintenance free, ready to connect
Application: General ventilation, Cooling industry, Farming and glass house ventilation
3
Axial Flow Fans
Axial Flow Fans Technical Data
AWA 1111-
Fan speed 1/min
Nominal motor voltage V
max. power consumption kW
Nominal motor current A
Capacitor µF
max. Media temperature °C
0200–2E 0200–4S 0250–2E 0250–4S 0300–2E 0300–4E
2650 1315 2500 1350 2550 1340
230 230 230 230 230 230
0.065 0.039 0.130 0.065 0.180 0.095
0.32 0.32 0.68 0.52 0.85 0.46
2 – 4 – 6 3
70 50 55 45 50 50
Weight appr. appr. kg 3 2 3.5 3 4.5 4.5
Technical Data
AQA 61
AWA 61
ARA 61
Fan speed 1/min
Nominal motor voltage V
max. power consumption kW
Nominal motor current A
0315–4D 0315–6D 0315–6D 0315–4E 0315–6E
1350 940 1405 925
230/400 230/400 230 230
0.11 0.07 0.11 0.06
0355–4D 0355–6D 0355–6D 0355–4E 0355–6E
1400 960 1340 920
230/400 230/400 230 230
0400–4D 0400–6D 0400–6D 0400–4E 0400–6E
1350 950 1320 935
0450–4D 0450–6D 0450–4E 0450–6E
ARA 62 Capacitor
ATA ATA 61
µF
max. Media temperature °C
Weight appr. appr. kg AQA AWA
ATA ATA
ARA
0.66/0.38 0.48/0.28 0.65 0.3
– – 3 2
45 45 50 50
5 5 5 5
4.5 4.5 4.5 4.5
3.5 3.5 3.5 3.5
5.7 5.7 5.7 5.7
0.18 0.09 0.16 0.07
0.78/0.45 0.52/0.3 0.95 0.4
– – 4 2
40 45 50 50
6 6 6.5 6.5
5.5 5.5 6 6
4 4 4.5 4.5
6.4 6.4 6.8 6.8
230/400 230/400 230 230
0.2 0.11 0.22 0.1
1.21/0.7 0.93/0.54 1.15 0.6
– – 6 3
50 50 45 60
9 9 9 9
8 8 8 8
6 6 6 6
8.8 8.8 9 9
1350 925 1290 935
230/400 230/400 230 230
0.3 0.16 0.35 0.18
1.37/0.79 1.18/0.68 1.9 1.15
– – 8 6
50 50 40 45
12 12 13 13
11 11 12 12
7.5 7.5 8 8
10.5 10.5 11 11
0500–4D 0500–6D 0500–4E 0500–6E
1440 960 1340 940
230/400 230/400 230 230
0.6 0.22 0.57 0.26
2.86/1.65 1.47/0.85 3.15 1.6
– – 16 10
50 55 50 50
18 17 18 18
16 15 16 16
12 10.5 12 12
14 14 16 16
0560–4D 0560–6D 0560–6D 0560–4E 0560–6E
1320 960 1330 960
230/400 230/400 230 230
1.19 0.45 1.3 0.59
4.47/2.58 2.9/1.7 6.25 3.2
– – 25 20
40 60 40 50
28 28 33 33
26 26 31 31
20 20 23 23
23 23 28 28
0630–4D 0630–6D 0630–6E
1320 945 945
230/400 230/400 230
1.65 0.58 0.7
5.54/3.2 3.2/1.85 3.5
– – 25
45 60 50
40 35 40
36 31 36
26 21 26
33 28 33
The motors are equipped with thermo contacts to prevent them against thermal overload. Each fan or service switch is provided with a wiring diagram The relevant wiring diagram may be found at:
www.nicotra-gebhardt.com
4
Axial Flow Fans
Axial Flow Fans Technical Data
AWA 1111-
Motor protection unit ESM
Transformer Transformer 7 taps ETO
Transformer Transformer 5-steps ETH
Speed regulator electronic EPH
Speed regulator electronic EPA
Speed regulator micro processor EPA
Speed controller electronic EPA
0200-2E 0200-4S 0250-2E 0250-4S 0300-2E 0300-4E
– – – – – –
10-0018-5E 10-0018-5E 10-0018-5E 10-0018-5E 10-0018-5E 10-0018-5E
31-0020-5E 31-0020-5E 31-0020-5E 31-0020-5E 31-0020-5E 31-0020-5E
03-0010-5E 03-0010-5E 03-0010-5E 03-0010-5E 03-0010-5E 03-0010-5E
03-0060-5E 03-0060-5E 03-0060-5E 03-0060-5E 03-0060-5E 03-0060-5E
93-0023-5E 93-0023-5E 93-0023-5E 93-0023-5E 93-0023-5E 93-0023-5E
83-0060-5E 83-0060-5E 83-0060-5E 83-0060-5E 83-0060-5E 83-0060-5E
Motor protection unit ESM
Transformer Transformer 7 taps ETO
Transformer Transformer 5-steps ETH
Speed regulator electronic EPH
Speed regulator electronic EPA
Speed regulator micro processor EPA
Speed controller electronic EPA
0315-4D 0315-6D 0315-4E 0315-6E
01-0040-8D 01-0040-8D 01-0020-5E 01-0020-5E
10-0010-8D 10-0010-8D 10-0018-5E 10-0018-5E
35-0010-8D 35-0010-8D 31-0020-5E 31-0020-5E
– – 03-0010-5E 03-0010-5E
– – 03-0060-5E –
– – 93-0023-5E 93-0023-5E
83-0050-8D – 83-0060-5E 83-0060-5E
0355-4D 0355-6D 0355-4E 0355-6E
01-0040-8D 01-0040-8D 01-0020-5E 01-0020-5E
10-0010-8D 10-0010-8D 10-0018-5E 10-0018-5E
35-0010-8D 35-0010-8D 31-0020-5E 31-0020-5E
– – 03-0010-5E 03-0010-5E
– – 03-0060-5E 03-0060-5E
– – 93-0023-5E 93-0023-5E
83-0050-8D 83-0050-8D 83-0060-5E 83-0060-5E
0400-4D 0400-6D 0400-4E 0400-6E
01-0040-8D 01-0040-8D 01-0020-5E 01-0020-5E
10-0010-8D 10-0010-8D 10-0018-5E 10-0018-5E
35-0010-8D 35-0010-8D 31-0020-5E 31-0020-5E
– – 03-0020-5E 03-0010-5E
– – 03-0060-5E 03-0060-5E
– – 93-0023-5E 93-0023-5E
83-0050-8D 83-0050-8D 83-0060-5E 83-0060-5E
0450-4D 0450-6D 0450-4E 0450-6E
01-0040-8D 01-0040-8D 01-0020-5E 01-0020-5E
10-0010-8D 10-0010-8D 10-0040-5E 10-0018-5E
35-0010-8D 35-0010-8D 31-0020-5E 31-0020-5E
– – 03-0020-5E 03-0020-5E
– – 03-0060-5E 03-0060-5E
– – 93-0023-5E 93-0023-5E
83-0050-8D 83-0050-8D 83-0060-5E 83-0060-5E
0500-4D 0500-6D 0500-4E 0500-6E
01-0040-8D 01-0040-8D 01-0020-5E 01-0020-5E
10-0020-8D 10-0010-8D 10-0040-5E 10-0018-5E
35-0020-8D 35-0010-8D 35-0040-5E 31-0020-5E
– – 03-0040-5E 03-0020-5E
– – 03-0060-5E 03-0060-5E
– – – 93-0023-5E
83-0050-8D 83-0050-8D 83-0060-5E 83-0060-5E
0560-4D 0560-6D 0560-4E 0560-6E
01-0040-8D 01-0040-8D 01-0020-5E 01-0020-5E
10-0040-8D 10-0020-8D 10-0070-5E 10-0040-5E
36-0040-8D 35-0020-8D 35-0070-5E 35-0040-5E
– – – 03-0040-5E
– – 03-0100-5E 03-0060-5E
– – – –
83-0050-8D 83-0050-8D 83-0100-5E 83-0060-5E
0630-4D 0630-6D 0630-6E
01-0040-8D 01-0040-8D 01-0020-5E
10-0040-8D 10-0020-8D 10-0040-5E
36-0040-8D 35-0020-8D 35-0040-5E
– – 03-0040-5E
– – 03-0060-5E
– – –
83-0050-8D 83-0050-8D 83-0060-5E
a t a D l a c i n h c e T
Technical Data
Motor protection unit is not required. The thermo contacts are fitted in series with the motor winding. They switch the motor off directly when a thermal overload occurs and they switch it on automatically after cooling down. An extra motor protection unit is not required when using speed control units of the types ETH 32-, ETH 36-, and EPA 03-. These control units are already equipped with a motor protection unit.
5
Axial Flow Fans
AWA AWA 11-0200/-0250/-0300 11-0200/-0250/-0300 Curves
r1 = 1.15 kg/m³
Pa
0200-2E
250
Pa
speed controllable
� 150
100
60
� = 230 V = 190 V = 165 V = 145 V = 125 V = 105 V = 85 V
200
0200-4S speed controllable
50
� = 230 V = 190 V = 165 V = 145 V = 125 V = 105 V = 85 V
�
40
30
W A 5
a f
� 0 100
200
6 8
6 1
5 2 0
L
W A 5
L
50
p
20
300
400
0. V
500
600
700
0.1
10
= 7 3 d B
a f
p
800 m³/h
0
speed controllable
50
100
150
0. V
m³/s
0250-2E
240
5 3
�0
0.2
Pa
200
250
300
= 5 8 d B
350
0.05
400 m³/h
0.1
Pa
m³/s
0250-4S
100
speed controllable
90
� = 230 V = 190 V = 165 V = 145 V = 125 V = 105 V = 85 V
200
� 160
120
70
50
p
W A 5
200
400
0. V
7 2
6 1
� 0 0
30
L
a f
40
40
60
80
= 230 V = 190 V = 165 V = 145 V = 125 V � = 105 V = 85 V
80
600
0. 1
800
1000
0.2
1200
p
0.4
m³/s
0300-2E
250
W A 5
6 0
4 8
� 0
1600 m³/h
Pa
L
10
a f
1400
0. 3
�
20
= 7 9 d B
0
100
200
300
0. V
400
500
600
0.1
700
800
900 m³/h
0.2
m³/s
Pa
0300-4E
140
speed controllable � = 230 V = 190 V = 165 V = 145 V = 125 V = 105 V = 85 V
200
� 150
100
speed controllable
80
W A 5
p
7 3
6 1
� 0 0 0. V
500 0.1
1000 0.2
Volume flow
1500
0. 3
0.4
2000 0.5
0.6
40
L
a f
�
100
60
= 8 0 d B 2500 m³/h 0.7 m³/s
� = 230 V = 190 V = 165 V = 145 V = 125 V = 105 V = 85 V
120
50
L
W A 5
20 a f
p
0 0. V
200
400 0. 1
600
800 0.2
provent
LWA5 at V· max dB
Folume flow V· in m3 /h at available pressure increase pfa in Pa 0 10 20 40 60
0200–2E 0200–4S 0250–2E 0250–4S 0300–2E 0300–4E
2650 1315 2500 1350 2550 1340
73 58 79 65 80 71
790 390 1570 860 2460 1720
360 800 1650
6 3
5 5
� 0
Fan Speed 1/min
6
= 6 5 d B
740 310 1490 720 2300 1575
1000
1200
0.3
= 7 1 d B
1400
1600 1800 m³/h
0.4
0.5 m³/s
r1 = 1.15 kg/m³
80
100
120
690
640
575
490
1420 480 2180 1400
1330
1230
1120
970
2020 1150
1850
1650
1350
Axial Flow Fans
Size 0315 Curves
r1 = 1.15 kg/m³
Pa
0315-4D
Pa
0315-6D
speed controllable
100
speed controllable 45
= 400 V = 330 V = 285 V = 250 V = 215 V � = 180 V = 150 V
90
80
70
40
� 35
30
60
50
� = 400 V = 330 V = 285 V = 250 V = 215 V = 180 V = 150 V
25
20
s e v r u C
�
40
15
30
10
20
L
W A 5
L
W A 5
10 a f
6 1
p
� 0 0
200
400
0. V
600
0. 1
800
1000
0. 2
1200
0. 3
6 5
5
= 6 9 d B
5 5
p
� 0
1400
1600 1800 m³/h
0.4
0.5 m³/s
Pa
5 8
a f
0315-4E
0
200
400
0. V
600
800
0. 1
m³/h
1000
0.2
0.3 m³/s
Pa
0315-6E
speed controllable
100
= 6 1 d B
speed controllable 45
= 230 V = 190 V = 165 V = 145 V = 125 V � = 105 V = 85 V
90
80
70
40
35
30
60
= 230 V = 190 V = 165 V = 145 V = 125 V � = 105 V = 85 V
25
50
20
�
40
�
15
30
10
20
L
W A 5
L
W A 5
10 a f
5 8
p
� 0 0
200
0. V
400
600
0. 1
Volume flow
800
1000
6 5
1200
0. 3
0. 2
5
= 6 9 d B
a f
5 0
p
� 0
1400
1600 1800 m³/h
0.4
0.5 m³/s
0
200
0. V
400
1000
0.2
provent
LWA5 at V· max dB
Folume flow V· in m3 /h at available pressure increase pfa in Pa 0 10 20 30 40
0315–4D 0315–6D 0315–6D 0315–4E 0315–6E
1350 940 1405 925
69 61 69 61
1680 1170 1700 1160
1500 815 1470 800
800
0. 1
Fan Speed 1/min
1600 1040 1600 1025
600
5 5
= 6 1 d B m³/h
0.3 m³/s
r1 = 1.15 kg/m³
50
1360
1200
1000
1340
1190
990
60 780
7
Axial Flow Fans
Size 0355 Curves
r1 = 1.15 kg/m³
Pa
0355-4D
Pa
0355-6D
speed controllable
speed controllable
= 400 V = 330 V = 285 V = 250 V = 215 V � = 180 V = 150 V
120
100
80
50
40
60
= 400 V = 330 V = 285 V = 250 V = 215 V � = 180 V = 150 V
60
30
� 20
�
40
L
W A 5
20
a f
6 8
6 1
p
� 0 0 0. V
500 0.1
1000 0.2
0.3
1500 0. 4
2000 0.5
0. 6
Pa
L
10
= 7 2 d B
W A 5
a f
5 6
p
� 0
2500
m³/h
0
0.7
m³/s
0. V
0355-4E
200
400
600
0. 1
800 0.2
1000
1200
0.3
6 0
1400
1600 1800 m³/h
0.4
0.5 m³/s
Pa
0355-6E
speed controllable
110
speed controllable
= 230 V = 190 V = 165 V = 145 V = 125 V � = 105 V = 85 V
100
90 80
�
40
60
� = 230 V = 190 V = 165 V = 145 V = 125 V = 105 V = 85 V
50
70
= 6 4 d B
30
50
40
30
20
�
20
W A 5
10 a f
5 5
p
� 0 0 0. V
500 0.1
10
L
1000 0.2
Volume flow
0.3
6 6
1500 0. 4
2000 0.5
0. 6
= 7 1 d B
L
W A 5
a f
5 4
p
� 0
2500
m³/h
0
0.7
m³/s
0. V
200
400 0. 1
600
800 0.2
provent
Fan Speed 1/min
LWA5 at V· max dB
Folume flow V· in m3 /h at available pressure increase pfa in Pa 0 10 20 30 40
0355–4D 0355–6D 0355–4E 0355–6E
1400 940 1340 920
72 64 71 64
2870 1900 2700 1880
8
2750 1700 2570 1700
2600 1500 2430 1470
2450 1150 2300 1140
2300 2100
1000
1200
0.3
6 0
= 6 4 d B
1400
1600 1800 m³/h
0.4
0.5 m³/s
r1 = 1.15 kg/m³
50
60
2150
1850
Axial Flow Fans
Size 0400 r1 = 1.15 kg/m³
Curves Pa
0400-4D
Pa
0400-6D
speed controllable 140
speed controllable 70
= 400 V = 330 V = 285 V = 250 V = 215 V � = 180 V = 150 V
120
100
60
�
50
80
� = 400 V = 330 V = 285 V = 250 V = 215 V = 180 V = 150 V
40
60
30
� 40
20
L
W A 5
20 a f
6 4
p
� 0 0 0. V
500
1000
0. 1
0. 3
0.2
1500 0. 4
2000 0. 5
6 9
2500
0. 6
0.7
3000 0. 8
L
0. 9
Pa
10
= 7 3 d B
3500
W A 5
a f
� 0 m³/h
0
1.0 m³/s
0400-4E
0. V
500 0.1
1000 0.2
0. 3
1500 0.4
0.5
0.6
Pa
0.7 m³/s
0400-6E speed controllable 70
� = 230 V = 190 V = 165 V = 145 V = 125 V = 105 V = 85 V
120
2500 m³/h
2000
speed controllable 140
6 3
5 9
p
= 6 6 d B
= 230 V = 190 V = 165 V = 145 V = 125 V � = 105 V = 85 V
60
100
50
�
80
40
60
30
� 20
40
L
20
W A 5
a f
5 9
p
� 0 0 0. V
500 0. 1
1000 0.2
0. 3
Volume flow
1500 0. 4
6 8
2000 0. 5
2500
0. 6
0.7
3000 0. 8
0. 9
L
10
= 7 3 d B
3500
W A 5
a f
5 5
p
� 0 m³/h
1.0 m³/s
0 0. V
500 0.1
1000 0.2
0. 3
provent
Fan Speed 1/min
LWA5 at V· max dB
Folume flow V· in m3 /h at available pressure increase pfa in Pa 0 10 20 30 40
0400–4D 0400–6D 0400–4E 0400–6E
1350 950 1320 935
73 66 73 66
3580 2500 3550 2450
3450 2300 3400 2260
3300 2100 3250 2050
3140 1800 3110 1740
6 3
1500 0.4
2000 0.5
0.6
= 6 6 d B 2500 m³/h 0.7 m³/s
r1 = 1.15 kg/m³
50
60
70
2975
2800
2500
2000
2900
2750
2400
2000
9
Axial Flow Fans
Size 0450 Curves
r1 = 1.15 kg/m³
Pa
0450-4D
Pa
0450-6D
speed controllable
speed controllable
180
90
= 400 V = 330 V = 285 V = 250 V = 215 V � = 180 V = 150 V
160
140
= 400 V = 330 V = 285 V = 250 V = 215 V � = 180 V = 150 V
80
70
120
60
100
50
40
80
�
60
30
�
40
20
L
L
W A 5
20 a f
6 7
p
� 0 0
1000
2000
0. V
7 3
3000
0. 5
4000
= 7 8 d B
1.0
10 a f
� 0 0
1.5 m³/s
Pa
0450-4E
6 0
p
m³/h
5000
W A 5
1000
2000
0. V
6 7
= 7 0 d B 4000 m³/h
3000
0.5
1.0
Pa
m³/s
0450-6E
speed controllable
speed controllable
180
90
� = 230 V = 190 V = 165 V = 145 V = 125 V = 105 V = 85 V
160
140
= 230 V = 190 V = 165 V = 145 V = 125 V � = 105 V = 85 V
80
70
� 120
60
100
80
40
60
30
40
50
� 20
L
W A 5
20 a f
6 9
5 9
p
� 0 0
1000
0. V
2000
3000
0. 5
Volume flow
4000
= 7 8 d B
1.0
10 a f
� 0 0
1000
2000
0. V
1.5 m³/s
provent
LWA5 at V· max dB
Folume flow V· in m3 /h at available pressure increase pfa in Pa 0 10 20 30 40 50
0450–4D 0450–6D 0450–4E 0450–6E
1350 925 1290 935
78 70 78 70
5450 3830 5500 3800
10
3600
5150 3400 5200 3400
3100 3100
4750 2780 4860 2800
= 7 0 d B 4000 m³/h
3000
0.5
Fan Speed 1/min
3620
6 5
5 6
p
m³/h
5000
L
W A 5
1.0
m³/s
r1 = 1.15 kg/m³
60
70
80
90
4350
3800
3450
4480
4000
3600
2000
Axial Flow Fans
Size 0500 Curves
r1 = 1.15 kg/m³
Pa
0500-4D speed controllable
240
� = 400 V = 330 V = 285 V = 250 V = 215 V = 180 V = 150 V
220 200 180
� 160
Pa
110
= 400 V = 330 V = 285 V = 250 V = 215 V � = 180 V = 150 V
100
90
80
140
0500-6D speed controllable
70
�
60 120
50
100
40
80
30
60
L
L
W A 5
40 20 a f
7 8
7 3
p
� 0 0
1000
2000
3000
0. V
4000
5000
6000
1.0
20
= 8 1 d B
7000
8000 m³/h
2.0
m³/s
Pa
0500-4E speed controllable
220
� = 230 V = 190 V = 165 V = 145 V = 125 V = 105 V = 85 V
200
180
160
140
10 a f
� 0 0
1000
2000
0. V
3000
0. 5
4000 1.0
= 7 2 d B m³/h
5000
1.5 m³/s
Pa
0500-6E speed controllable
110
� = 230 V = 190 V = 165 V = 145 V = 125 V = 105 V = 85 V
100
90
� 80
70
60
100
7 0
6 7
p
�
120
W A 5
50
80
40
60
30
40
20 a f
7 3
6 2
p
� 0 0
1000
20
L
W A 5
2000
3000
0. V
4000
5000
1.0
Volume flow
6000
L
W A 5
= 8 0 d B
10 a f
� 0
7000
8000 m³/h
2.0
m³/s
0
1000
0. V
2000
provent
Folume flow V· in m3 /h at available pressure increase pfa in Pa 0 20 40 60 80
0500–4D 0500–6D 0500–4E 0500–6E
1440 960 1340 940
81 72 80 71
8600 5800 8050 5550
7580 3850 6950 3400
4000
5000
1.0
LWA5 at V· max dB
7900 4700 7350 4500
3000
0. 5
Fan Speed 1/min
8290 5300 7700 5100
6 8
6 0
p
= 7 1 d B m³/h
1.5 m³/s
r1 = 1.15 kg/m³
100
120
140
7100
6650
6000
4500
6500
5900
5000
11
Axial Flow Fans
Size 0560 Curves
r1 = 1.15 kg/m³
Pa
0560-4D
Pa
0560-6D
speed controllable � = 400 V = 330 V = 285 V = 250 V = 215 V = 180 V = 150 V
240
200
�
speed controllable 140
= 400 V = 330 V = 285 V = 250 V = 215 V � = 180 V = 150 V
120
100
160
�
80
120
60
80 40
L
W A 5
40
a f
7 7
7 3
p
L
= 8 4 d B
W A 5
20 a f
� 0
� 0 0
2000
0. V
4000
6000
8000 2. 0
1.0
10000
12000
m³/h
0
m³/s
0. V
3. 0
Pa
0560-4E
7 4
7 0
p
2000
4000
6000
1.0
= 230 V = 190 V = 165 V = 145 V = 125 V � = 105 V = 85 V
200
2.0
m³/s
Pa
0560-6E speed controllable
140
= 230 V = 190 V = 165 V = 145 V = 125 V � = 105 V = 85 V
120
100
160
80
�
120
80
60
40
L
L
W A 5
W A 5
� 40
7 9
7 2
6 2
a f
= 8 4 d B
= 7 6 d B
20
p
7 1
6 5
a f
p
� 0
� 0 0 0. V
2000
4000
6000
1.0
Volume flow
8000 2. 0
10000 3. 0
12000
m³/h
0
m³/s
0. V
2000
4000
provent
Folume flow V· in m3 /h at available pressure increase pfa in Pa 0 20 40 60 80 90
0560–4D 0560–6D 0560–4E 0560–6E
1320 960 1330 960
84 76 84 76
12500 8900 13000 9100
8600
11700 7900 12200 8000
7250 7300
10800 6200 11300 6400
8000 2.0
LWA5 at V· max dB
8400
6000
1.0
Fan Speed 1/min
12
m³/h
8000
speed controllable 240
= 7 6 d B
5700
m³/h m³/s
r1 = 1.15 kg/m³
120
160
9900
8150
10300
9000
180
7900
Axial Flow Fans
Size 0630 Curves
r1 = 1.15 kg/m³
Pa
0630-4D speed controllable
280
� = 400 V = 330 V = 285 V = 250 V = 215 V = 180 V = 150 V
240
�
Pa
0630-6D
160
speed controllable
140
� 120
200
100
160
� = 400 V = 330 V = 285 V = 250 V = 215 V = 180 V = 150 V
80
120 60
80
40
L
L
W A 5
W A 5
= 8 8 d B
40 a f
8 3
7 4
p
� 0 0
2000
0. V
4000
6000
1.0
8000
a f
7 2
p
� 0
10000 12000 14000 16000 m³/h 3.0
2.0
4.0
= 8 1 d B
20
0
m³/s
2000
4000
0. V
6000
1. 0
7 7
8000
m³/h
10000
2.0
3.0 m³/s
Pa
0630-6E
160
speed controllable � = 230 V = 190 V = 165 V = 145 V = 125 V = 105 V = 85 V
140
120
�
100
80
60
40
L
W A 5
20 a f
� 0 0
2000
0. V
Volume flow
4000
6000
1. 0
provent
LWA5 at V· max dB
Folume flow V· in m3 /h at available pressure increase pfa in Pa 0 20 40 60 80 90
0630–4D 0630–6D 0630–6E
1320 945 945
88 81 80
16550 11500 11400
15550 10300 10100
9500 9300
14550 8200 8000
8000
10000
2.0
Fan Speed 1/min
11000 10750
7 6
6 6
p
= 8 0 d B m³/h
3.0 m³/s
r1 = 1.15 kg/m³
120
160
180
13450 7150 7000
13
Axial Flow Fans
AWA AWA 11-0200/-0300 AWA AWA 61-0315/-0630 Dimensions in mm, subject to change AWA 11- 0200/ -0250 AWA 11- 0300 b3 b4
b3 b4
a 1
d 4 ø
a
2
3 d 1 2 d d ø ø ø
2 d 1 d ø ø
ø e
b5 b2
b2
AWA AWA 11-
b2
b3
b4
b5
ød1
ød2
ød3
ød4
øe
1
2
0200– 0250– 0300–2E 0300–4E
6 6 11 11
89 94 89 89
75 79 69 69
– – 12 2
280 320 397 397
200 254 306 306
– – 326 326
7 7 9 9
250 295 380 380
15° 15° 15° 15°
6×60° 6×60° 6×60° 6×60°
Dimensions in mm, subject to change AWA 61- 0315/ -0355 AWA 61- 0400/ -0630
ZSG 06 Inlet guard a
2
1 3 2 d 1 d 3 d ø d ø ø ø
1 3 2 d 1 d 3 d ø d ø ø ø
b4 b5
b4
b3
b5
ø d4 h
b3
øe
Dimension b3 for b3 for pole-types –4D –4E –6D
AWA 6161-
b4
~b5
ød1
ød2
ød3
~ød31
ød4
øe
h
2
0315 0355 0400 0450 0500 0560 0630
84 100 108 120 135 180 180
25 20 40 30 30 50 50
465 514 565 625 694 790 880
315 355 400 450 500 560 630
330 370 415 465 516 576 646
390 430 495 550 610 690 770
10 10 10 10 10 12 12
432 482 532 592 662 754 844
40 40 50 50 50 60 60
12×30° ~120 12×30° ~120 12×30° ~120 12×30° ~140 12×30° ~150 16×22.5° ~190 16×22.5° ~220
14
~120 ~120 ~120 ~150 ~150 ~220 –
~120 ~130 ~120 ~140 ~135 ~190 ~190
–6E ~120 ~130 ~120 ~150 ~150 ~220 ~220
Axial Flow Fans
AQA 61-0315/-0630 61-0315/-0630 AT ATA 61-0315/-0630 Dimensions in mm, subject to change AQA 61-03 15/-0 355 AQA 61-04 00/- 0630
ZSG 06 Inlet guard
b2
b2
3 2 d 1 3 d ø d ø ø
3 2 d 1 3 d ø d ø ø
b4 b5
b4
b3
b5
ø d4
b3
h
� a � l
AQA 61-
a
b2
b4
~b5
ød2
ød3
~ød31
ød4
h
350 400 460 515 615 675 750
8 8 10 10 15 15 15
78 93 100 112 115 165 170
33 30 50 45 45 65 65
315 355 400 450 500 560 630
330 370 415 465 516 576 646
390 430 495 550 610 690 770
10.5 10.5 10.5 10.5 11 11 11
40 40 50 50 50 60 60
0315 0355 0400 0450 0500 0560 0630
Dimensions in mm, subject to change ATA ATA 61 -0315 /-035 5
b5
l
410 460 520 575 655 725 805
–6E
~110 ~110 ~110 ~130 ~140 ~180 ~210
~110 ~120 ~110 ~140 ~140 ~210 ~210
~110 ~110 ~110 ~140 ~140 ~210 –
~110 ~120 ~110 ~130 ~125 ~180 ~180
s n o i s n e m i D
ATA ATA 61 -0400 / - 0630
5 d
5 d
ø
ø
ø d4 ø d11 øe
b1
Dimension b3 for b3 for pole-types –4D –4E –6D
b5
ø d4 ø d11 øe
b1
ATA ATA 61-
b5
ød4
ød5
ød11
øe
Dimension b1 for b1 for pole-types –4D –4E
–6D
–6E
0315 0355 0400 0450 0500 0560 0630
25 20 40 30 30 50 50
7 7 9 9 9 11 11
308 350 394 440 493 552 620
350 400 435 495 560 615 725
375 425 470 530 600 662 760
~120 ~120 ~120 ~140 ~150 ~190 ~220
~120 ~130 ~120 ~140 ~135 ~190 ~190
~120 ~130 ~120 ~150 ~150 ~220 ~220
~120 ~120 ~120 ~150 ~150 ~220 –
15
Axial Flow Fans
ARA 61-0315/-0630 61-0315/-0630 Dimensions in mm, subject to change ARA 61-0315/-0630 a — 2
a
1 2 d d ø ø
b
ø d4 øe
ARA 61-
b
b5
d1
d2
d4
e
0315 0355 0400 0450 0500 0560 0630
160 160 180 180 200 260 250
– – – – – – –
380 420 470 523 573 639 712
315 355 400 450 500 560 630
9.5 9.5 9.5 9.5 9.5 11.5 11.5
356 395 438 487 541 605 674
8×45° 8×45° 12×30° 12×30° 12×30° 16×22.5° 16×22.5°
Accessories Protection guard ZSG 04-
Flexible connection ZKE 11-
Protection guard ZSG 04-
z × d4
3 d ø
e ø
h
b1
o
m
x
ø d5
y
v
ZKD 01Flanged inlet cone
0315 0355 0400 0450 0500 0560 0630
w
ZBF 01Housing feet
ZKF 11Mating flange
b1
b3
b5
e
h
m
o
v
w
x
y
z×d4
81 61 105 118 136 75 175
464 515 565 640 710 785 837
9.5 9.5 9.5 9.5 9.5 11.5 11.5
356 395 438 487 541 605 674
225 250 280 315 355 400 450
30 30 30 35 35 35 35
130 130 130 130 130 130 130
210 210 240 240 258 295 324
240 280 340 375 415 415 450
176 176 200 200 218 245 274
200 240 300 335 370 370 400
8× 9.5 8× 9.5 6× 9.5 6× 9.5 6× 9.5 8×11.5 8× 9.5
Anti-vibrations mounts and automatic automatic shutter see accessories. accessories.
16
Axial Flow Fans
ARA 62-0315/-0630 62-0315/-0630 Dimensions in mm, subject to change ARA 62-0315/-0630 a — 2
a
1 d d 2 ø d ø ø
min bmax
ø d4 øe
ARA 62-
(min. - max.)* max.)* b
d
d1
d2
d4
e
h
0315 0355 0400 0450 0500 0560 0630
315 - 365 315 - 365 315 - 375 315 - 375 315 - 385 315 - 395 315 - 405
323 363 408 459 511 571 643
380 420 470 523 573 639 712
315 355 400 450 500 560 630
9.5 9.5 9.5 9.5 9.5 11.5 11.5
356 395 438 487 541 605 674
40 40 50 50 50 60 60
8×45° 8×45° 12×30° 12×30° 12×30° 16×22.5° 16×22.5°
Accessories Protection guard, inlet ZSG 04-
Protection guard, discharge (attachment) ZSG 06-
e ø
h
17
Axial Flow Fans
AWA AWA 11-
0200/-0300
Specifications, underlined at choice AWA 11-0200/-0300 11-0200/-0300
High performance axial flow fan provent with with direct drive Casing incorporating an inlet ring of painted sheet steel, integrated guard fitted conforming to DIN EN 294. Impeller made of galvanised sheet steel shrink-fitted onto the rotor of the integral motor, statically and dynamically balanced. Integral motor protected to IP 54. Sealed deep groove ball bearings, totally maintenance-free. Motor protected protected by built in thermal overload safety switch. Single phase 230 V, 50 Hz, 100% speed controlled.
with wall mounting ring
Volume flow
AWA 11- . 11- . . . . . . . . . . . . . . . . V = . . . . . . . . . . . . . . . m³/h m³/ h
pressure increase
pfa
= . . . . . . . . . . . . . . . Pa
Media temperature tempera ture
t
= . . . . . . . . . . . . . . . °C
Motor power consumption
Pe
= . . . . . . . . . . . . . . . kW
Speed Spee d
n
= . . . . . . . . . . . . . . . 1/min 1/mi n
Free inlet sound power level
LWA5 = . . . . . . . . . . . . . . . dB
Weight Weig ht
m
Fan-Type
= . . . . . . . . . . . . . . . kg
Accessories and options (at extra cost) Speed control units (step less, step wise, with, or without casing available) Motor protection unit Automatic back draught damper damper
18
Axial Flow Fans
AWA AWA 61- / AQA 61-/ AT ATA 61Specifications, underlined at choice AWA 61-0315 / -0630 AQA 61-0315 / -0630
0315/-0630 High performance axial flow fan provent with with direct drive. Casing incorporating an inlet ring of galvanised sheet steel and painted, integrated guard fitted conforming to DIN EN 294. Plastic impeller bolted to the rotor of the integral motor, statically and dynamically balanced. Integral motor protected to IP 54. Sealed deep groove ball bearings, totally maintenance-free. Motor protected by built in thermal overload thermo contacts operating in connection with motor protection unit. Ready to connect with a VDE conforming terminal box. Three phase 230/400 V, V, 50 Hz, or single single phase 230 V, 50 Hz, 100% speed controlled.
with with wall wall moun mounti ting ng ring ring
with with squa square re wall wall moun mounti ting ng plate ...............
Fan-Type Volume flow
. V
= . . . . . . . . . . . . . . . m³/h m³/ h
pressure increase
pfa
= . . . . . . . . . . . . . . . Pa
Media temperature tempera ture
t
= . . . . . . . . . . . . . . . °C
Motor power consumption
Pe
= . . . . . . . . . . . . . . . kW
Speed Spee d
n
= . . . . . . . . . . . . . . . 1/min 1/mi n
Free inlet sound power level
LWA5 = . . . . . . . . . . . . . . . dB
Weight Weig ht
m
= . . . . . . . . . . . . . . . kg
Accessories and options (at extra cost) Guard at discharge Automatic back draught damper damper Motor protection unit Speed control units (step less, step wise, with, or without casing available) Increased corrosion protection
Specifications, underlined at choice AT ATA 61-0315 / -0630
High performance axial flow fan provent with with direct drive. Self supporting integrated guard fitted conforming to DIN EN 294. Plastic impeller bolted to the rotor of the integral motor, statically and dynamically balanced. Integral motor protected to IP 54. Sealed deep groove ball bearings, totally maintenance-free. Motor protected by built in thermal overload thermo contacts operating in connection with motor protection unit. Ready to connect with a VDE conforming terminal box. Three phase 230/400 V, V, 50 Hz, or single single phase 230 V, 50 Hz, 100% speed controlled.
with self supporting inlet guard
Volume flow
ATA ATA 61- . 61- . . . . . . . . . . . . . . . . V = . . . . . . . . . . . . . . . m³/h m³/ h
pressure increase
pfa
= . . . . . . . . . . . . . . . Pa
Media temperature tempera ture
t
= . . . . . . . . . . . . . . . °C
Motor power consumption
Pe
= . . . . . . . . . . . . . . . kW
Speed Spee d
n
= . . . . . . . . . . . . . . . 1/min 1/mi n
Free inlet sound power level
LWA5 = . . . . . . . . . . . . . . . dB
Weight Weig ht
m
Fan-Type
= . . . . . . . . . . . . . . . kg
Accessories and options (at extra cost) Automatic back draught damper damper Speed control units (step less, step wise, with, or without casing available)
19
s n o i t a c i f i c e p S
Axial Flow Fans
ARA 61-
0315/-0630
Specifications, underlined at choice ARA 61-0315 / -0630
High performance axial flow fan provent with with direct drive
duct mounted casing
Duct mounted casing with connecting flanges on both sides, made from sheet steel and powder coated or hot hot dip galvanised (extra cost) lastic impeller bolted to the rotor of the i ntegral motor, motor, statically and dynamically balanced. Integral motor protected to IP 54. Sealed deep groove ball bearings, totally maintenance-free. Motor protected by built in thermal overload thermo contacts operating in connection with motor protection unit. Ready to connect with a VDE conforming terminal box, fully wired and fitted on casing. Three phase 230/400 V, V, 50 Hz, or single single phase 230 V, 50 Hz, 100% speed controlled.
Volume flow
ARA 61- . 61- . . . . . . . . . . . . . . . . V = . . . . . . . . . . . . . . . m³/h m³/ h
pressure increase
pfa
= . . . . . . . . . . . . . . . Pa
Media temperature tempera ture
t
= . . . . . . . . . . . . . . . °C
Motor power consumption
Pe
= . . . . . . . . . . . . . . . kW
Speed Spee d
n
= . . . . . . . . . . . . . . . 1/min 1/mi n
Free inlet sound power level
LWA5 = . . . . . . . . . . . . . . . dB
Weight Weig ht
m
Fan-Type
= . . . . . . . . . . . . . . . kg
Accessories and options (at extra cost) Flexible connectors w/flanges on both sides Mating flange Guard (at intake and discharge) Intake cone w/flange Brackets Anti vibration mounts Automatic back draught damper damper Motor protection unit Speed control unit (step less, step wise, with, or without casing available) Tube Tube casing protected protected by hot dip galvanisation
20
Axial Flow Fans
ARA 62-
0315/-0630
Specifications, underlined at choice ARA 62-0315 / -0630
High performance axial flow fan provent with with direct drive
duct mounted for flush mounting
Duct mounted for flush mounting in long casing design, made from sheet steel and powder coated or hot hot dip galvanised (extra cost) Plastic impeller bolted to the rotor of the integral motor, motor, statically and dynamically balanced. Integral motor protected to IP 54. Sealed deep groove ball bearings, totally maintenance-free. Motor protected by built in thermal overload thermo contacts operating in connection with motor protection unit. Ready to connect with a VDE conforming terminal box, fully wired and fitted on casing. Three phase 230/400 V, V, 50 Hz, or single single phase 230 V, 50 Hz, 100% speed controlled.
Volume flow
ARA 62- . 62- . . . . . . . . . . . . . . . . V = . . . . . . . . . . . . . . . m³/h m³/ h
pressure increase
pfa
= . . . . . . . . . . . . . . . Pa
Media temperature tempera ture
t
= . . . . . . . . . . . . . . . °C
Motor power consumption
Pe
= . . . . . . . . . . . . . . . kW
Speed Spee d
n
= . . . . . . . . . . . . . . . 1/min 1/mi n
Free inlet sound power level
LWA5 = . . . . . . . . . . . . . . . dB
Weight Weig ht
m
Fan-Type
= . . . . . . . . . . . . . . . kg
Accessories and options (at extra cost) Guard at intake Guard at discharge Automatic back draught damper damper Motor protection unit Speed control unit (step less, step wise, with, or without casing available) Tube Tube casing protected protected by hot dip galvanisation
21
Axial Flow Fans
Accessories Samples Fitted to an outside wall, automatic, weather proof back draught damper at discharge.
AQA 61ZLK 40
Samples Fitted to a wood or metal wall with clipped guard at discharge.
AWA 61ZSG 06
22
Axial Flow Fans
Accessories Samples Installation with anti-vibration fittings, intake cone, automatic draught damper at discharge.
ZSG 04
ducted tube
ARA 61-
ZKD 01
ZKE 11
ZLK 40
ZBF 01
ZBD 01
Samples Flush mounted fan unit, with guards, bolted at intake and clipped at discharge.
ZSG 06
ZSG 04
Samples Flush mounted fan unit, with flexible fabrics, bolted at intake and fitted at discharge.
s e i r o s s e c c A
23
Axial Flow Fans
Accessories Overview 5 ZSG 06 Protection guard, attachment for discharge
6 ZLK 40 Automatic shutter
Overview ZKE 11 Flexible connection
ZKF 11 Flange 3 ZSG 04 Protection guard 4 ZKD 01 Flanged inlet cone 6 ZLK 40 Automatic shutter
7 ZBF 11 Housing feet 8 ZBD 01 Rubber buffers
Overview 3 ZSG 04 Protection guard
5 ZSG 06 Protection guard, attachment for discharge
6 ZLK 40 Automatic shutter
24
Axial Flow Fans
Accessories Flanges and Connections For line ARA 61 There are flanges and flexible connectors available for intake and discharge
ZKE 11
ZKF 11
Protection Guard For line AQA 61, AWA 61, ATA 61, The axial flow fans are equipped with intake guard as a standard. Guards for discharge are available as an accessory (ZSG 06)
For line ARA 61, ARA 62 ZSG 04
ZSG 06
These fans are made for being integrated in a duct system or for wall flush mounting and are not supplied with an intake guard. If there is – by the way of installation or use the fan - no guard provided against a contact with the fan impeller the user has to ensure an appropriate protection according to DIN EN 294. Matching guards are available as an accessory. accessory.
Flanged inlet cone For line ARA 61 The intake cone with flange has to be fitted to the intake of the inline fan if there is no duct connected. This will improve the intake flow conditions and reduce air flow losses.
ZKD 01
Automatic shutter For weather proof cover of the discharge openings. The automatic back draught damper is made of shock proof, weather and UV- resistant plastic material, colour light grey. It is supply ready for fitting including nuts and bolts.
The back draught damper is made for use under a temperature range of -30 °C to +70 °C. ZLK 40
Dimensions in mm, subject to change ZLK 40-
a
b
c
d
e
app. kg
0200 0225 0315 0355 0400 0450 0500 0560 0630
210 260 310 360 420 460 510 – –
244 294 347 397 459 501 549 605 696
182 232 276 310 364 395 445 522 626
22 26 26 26 26 26 31 28 31
5 5 5 5 5 5 5 5 5
0.3 0.5 0.7 0.9 1.2 1.7 2.0 2.5 3.0
a
b
e
d
c
25
Axial Flow Fans
Accessories Casing feet For line ARA 61 Anti vibration mounts are made for reducing vibrations to the floor base. In combination with the brackets they may be fitted to the inline fan unit.
ZBF 01
Anti-vibration mounts For line ARA 61 Anti vibration mounts are made for reducing vibrations to the floor base. In combination with the brackets they may be fitted to the inline fan unit.
Dimensions in mm, subject to change Fan ARA 61-
Quantity
0415/-0450 0500/-0630
4 4
Rubber buffers ZBD 01-
A
E
F
G
H
K
0405 0606
20 30
25 30
16 20
M6 M8
M6 M8
6.5 9.5
H
F
E K
G
A
26
Axial Flow Fans
Accessories
ESM
Motor protection unit for motors with fitted thermal control sensors (thermal contacts, PTC)
Design Beautifully shaped plastic casing made of shock resistant polystyrol, protection class IP 54. All units are suitable for wall mounting mounting and include: hand hand switches for frontal operatioperation, operational signal lamp and control safety accessible from outside. Permissible ambient temperature: +40 °C.
Function Should the motor winding temperature rise excessively, the imbedded motor winding thermal contact or PTC will open the control circuit, causing the mains relay to drop out and thus disconnect the motor from the mains supply. The motor will also be turned off off in the case of a mains-side mains-side dropout of the control phase, as well as if the contacts fail or if the mains supply is interrupted. The motor protection units are not equipped equipped with an automatic re-poweron re-poweron after a mains voltage failure and are thus fail-safe. After the motor windings have cooled down, a lock-out device device in the relay circuit circuit prevents the motor from switching itself on. The hand switch must first be momentarily turned to the 0-position and then back to the ‘on’ position. The operational signal lamp indicates the operation of the motor. motor. It goes out in the case of a malfunction. The motor protection units are suitable for group group switching, i. e. several motors motors with the same switching can be connectedto a common switchingdevice. The sum of the motors’ rated rated power may not exceed exceed the maximal device rated rated power. wer. The thermal contacts of all motors are to be switched in series. The PTCs switched in series may not exceed the sum of 6.
Technical Data for motors with thermal contacts ESM
max. permitted rated motor power kW
Nominal voltage V
Weight kg
01-0020-5E 01-0040-8D 02-0040-8D 03-0040-8D 04-0040-8D
2.0 4.0 4.0 4.0 4.0
230 400 400 400 400
0.9 0.9 0.9 0.9 0.9
for motors with PTC ESM
max. permitted rated motor power kW
Nominal voltage V
Weight kg
11-0040-8D 12-0040-8D 13-0040-8D
4.0 4.0 4.0
400 400 400
0.9 0.9 0.9
For connection type see diagrams
Dimensions in mm, Subject to change
0 3
0 4 1
190
150
Please use the enclosed wiring diagrams in the control boxes always!
27
Axial Flow Fans
Accessories
ESM
Motor protection unit Connection diagram ESM 01-0020-5E Alternating current model model,, single speed ATTENTION: ATTENTION: for thermo thermo contacts (TK) (TK) use always series connection! N L1
T K T K TK TK
U1 U1 U 1 U 2 U2 U2
TK U1
Z2
TK
U2
Z1
Anti-clockwise Anti-clockwise rotation T K T K TK TK TK
TK
TK TK
Connection with 2 motors TK U1 Z2 T K T K TK TK TK TK
Z1 U2
Clockwise rotation
TK TK
TK TK
PE N L1
Main Mainss
TK
Conn Connec ecti tion on with with 3 mot motor orss
Motor 1-phase
Connection diagram ESM 01-0040-8D Three-phase current model, model , single speed
ESM 02-0040-8D Three-phase current model, model , 2 speed with two separate windings
ATTENTION: ATTENTION: for thermo thermo contacts (TK) (TK) use always series series connection!
ATTENTION: ATTENTION: for thermo thermo contacts (TK) (TK) use always series series connection!
N L1 L2 L3
N L1 L2 L3
TK TK TK TK
U1 U1 U1 V1 V1 V1 W1 W1 W1
T K TK TK TK
TK TK TK TK
T K T K TK TK
TK TK TK TK
TK
Connection with 2 motors
TK
TK TK TK TK
Mains
U1
V1
W1
TK W2
U2
V2
TK TK
TK
T K T K TK TK TK
PE N L1 L2 L3
Connection wi with 3 motors
TK
Connection with 2 motors
TK TK TK TK
PE N L1 L2 L3
TK
1U 1V 1 W 2U 2V 2W
Motor 3-phase
Mains
TK
TK
TK
TK
TK
Connection wi with 3 motors
U1
V1
W1
TK W2
TK
U2
V2
Motor 3-phase
Connection diagram ESM 03-0040-8D Three-phase current model, model , 2 speed with Dahlander winding
ESM 04-0040-8D Three-phase current model, model , 2 speed with Y/ -connection
ATTENTION: ATTENTION: for thermo thermo contacts (TK) (TK) use always series connection!
ATTENTION: ATTENTION: for thermo thermo contacts (TK) (TK) use always series series connection!
N L1 L2 L3
N L1 L2 L3
T K T K TK TK
1U 1V 1W 2U 2V 2W
T K TK TK TK
TK
T K TK TK
TK
TK
TK
TK
TK
TK
Connection with 2 motors
T K TK TK TK
PE N L1 L2 L3
Mains
28
T K T K TK TK
TK TK
TK
TK
TK
TK
Connection wi with 3 motors
TK
U1 V1 W 1 U 2 V2 W2
TK
Connection with 2 motors
TK
1U
1V
1W
TK 2W
2U
2V
TK TK
PE N L1 L2 L3
Motor 3-phase
Mains
T K TK TK
TK
U1
V1
W1
TK
TK
TK W2
U2
V2
TK
TK
TK
Connection with 3 motors
Motor 3-phase
Axial Flow Fans
Accessories
ESM
Motor protection unit
Connection diagram ESM 11-0040-8D Three-phase current model, model , single speed
ESM 12-0040-8D Three-phase current model, model , 2 speed with two separate windings
ATTENTION: ATTENTION: for PTC PTC (KL) use always series connection! connection! N L1 L2 L3
KL KL KL KL
ATTENTION: ATTENTION: for PTC PTC (KL) use always series connection! connection!
U1 U1 U1 V1 V1 V1 W1 W1 W1
N L1 L2 L3
K L KL
KL
KL KL KL KL
K L KL
KL
KL
KL KL KL KL
KL
KL
KL
Connection with 2 motors
KL
U1
V1
W1
KL KL KL KL
KL
W 2 U2
V2
KL KL
K L KL KL
PE N L1 L2 L3
Connection wi with 3 motors
KL
1U 1V 1 W 2 U 2V 2W
Connection with 2 motors
KL KL KL KL
PE N L1 L2 L3
Mains
KL
Motor 3-phase
Mains
KL
KL
KL
U1
V1
W1
KL
KL
KL
KL
W 2 U2
V2
KL
KL
Connection wi with 3 motors
Motor 3-phase
Connection diagram ESM 13-0040-8D Three-phase current model, model , 2 speed with Dahlander winding ATTENTION: ATTENTION: for PTC PTC (KL) use always series connection! connection! N L1 L2 L3
KL
K L KL
KL
KL
KL
KL
KL
KL
KL
KL
KL
1U 1V 1 W 2U 2V 2W
Connection with 2 motors
PE N L1 L2 L3
Mains
KL
KL
KL
KL
KL
1U
1V
1W
KL
KL
KL
KL
KL
2 W 2U
2V
KL
KL
Connection wi with 3 motors
Motor 3-phase
29
Axial Flow Fans
Accessories
ETO
Transformer with 7 secondary taps
Design Transformer Transformer according to DIN VDE 0550-1 with built-on built-on terminal strip for 7 taps, without casing, suitable for control cabinet installation. Two Two transformers are necessary necessary for three-phase three-phase current, which are are to beconnected beconnected in a V-switching configuration (see Wiring diagram). Permissible ambient temperature at nominal current loading max. +35 °C.
ETO 10-....-5E Primary voltage: 230 V / 50-60 Hz Secondary voltage: 230/180/160/140/120/100/80 V
ETO 10-....-8D Primary voltage: 400 V / 50-60 Hz Secondary voltage: 400/310/270/235/200/170/140 V
Technical Data | Dimensions Alternating current model model Nominal current ETO A 10-0018-5E 10-0040-5E 10-0070-5E 10-0130-5E 10-0130-5E 10-0220-5E
1.8 4.0 7.0 13.0 13. 0 22.0
Dimensions in mm, Subject to change a b c e øf
h
kg
78 96 120 135 135
44 61 73 86 126
1.5 2.5 4.5 7.0 12.5
Dimensions in mm, Subject to change a b c e øf
h
kg
78 96 120 135 135
44 61 73 86 126
1.5 2.5 4.5 7.0 12.5
60 80 95 110 150
92 107 126 135 135
56 84 90 104 104
4.8 5.8 5.8 5.8 5.8
Technical Data | Dimensions Three-phase current model Nominal current ETO A 10-0010-8D 10-0020-8D 10-0040-8D 10-0065-8D 10-0150-8D
1.0 2.0 4.0 6.5 15.0
60 80 95 110 150
92 107 126 135 135
56 84 90 104 104
4.8 5.8 5.8 5.8 5.8
Measurement diagram
c
øf h b
e a
Connection diagram ETO 10-....-5E Mains L
ETO 10-....-8D Motor
N
U1
Mains U2
V V V V V V V V 0 0 0 0 0 0 0 0 3 8 6 4 2 0 8 2 1 1 1 1 1
30
L1
Motor L2 L3
V V V V V V V V 0 0 0 5 0 0 0 0 0 1 7 3 0 7 4 4 3 2 2 2 1 1
U1
V1
W1
V V V V V V V V 0 0 0 0 5 0 0 0 4 7 0 3 7 1 0 1 1 2 2 2 3 4
Axial Flow Fans
Accessories
ETH
Speed setting transformatic, 5-step, with casing
Design Completely plastic casing in protection class IP 54, Type: ETH 31, 35 and ETH 37-0010/-0020-8D. 37-0010/-0020-8D. Painted metal casing in protection class IP 23, Type: ETH 36 and ETH 37-0040/-0070-8D. All units are suitable for wall mounting mounting and include: speed speed control via hand switch with 0-position and 5 switching steps, operating signal lamp, 230 V output for e. g. a solenoid valve. Permissible ambient temperature: -25 °C up to +40 °C.
ETH 31 These units include no motor motor protection unit. Protection Protection switches for thermal thermal contact connections are to be laid in the conductor between the control device and the motor. In Nicotra Gebhardt externallymounted rotor motors, the thermal contacts are already bound into the motor winding.
ETH 35, ETH 36, ETH 37 These units possess a motor protection protection installation for thermal thermal contact or PTC connection with a supplementary warning signal lamp, a potential-free exchanger exchanger and a room thermostat connection (remote on – off).
Function For motors with built-in thermal contacts, these open the control current circuit when the permissible winding temperature is exceeded (ETH 31, 35, 36). Motors equipped with PTC thermistor give an electrical signal to the trigger unit (ETH 37) when the temperature exceeds the default value. The trigger controls the main relay thus cutting the motor feed. This causes the main fuse to fall out and disconnect the motor from the mains. After the motor winding has cooled cooled down (ca. 2 Min.) or after remedying the the cause of the malfunction, respectively, respectively, turn the main switch temporarily to the 0-position and then back to the operational position.
31
Axial Flow Fans
Accessories
ETH
Speed setting transformatic, 5-step, with casing
Technical Data Primary voltage: 230 V; 50-60 Hz Secondary voltage: 60/105/130/160/230 V
Alternating current model model without motor protection installation Nominal current Mains safety ETH A 31-0020-5E 31-0040-5E
2.0 4.0
with motor protection installation Nominal current Mains safety ETH A
2 AT 6 AT
4.0 6 AT 7.0 8 AT 20.0 20 AT
35-0040-5E 35-0070-5E 36-0200-5E
Technical Data Primary voltage: 400 V; 50-60 Hz Secondary voltage: 90/140/180/230/400 V
Three-phase current model with motor protection installation Nominal current Mains safety ETH A 1.0 1 AT 2.0 2 AT 4.0 4 AT 7.0 8 AT 14.0 16 AT
35-0010-8D 35-0020-8D 36-0040-8D 36-0070-8D 36-0140-8D
with motor protection installation for motors with PTC Nominal current Mains safety ETH A 1.0 2.0 4.0 7.0
37-0010-8D 37-0020-8D 37-0040-8D 37-0070-8D
1 AT 2 AT 4 AT 8 AT
Dimensions in mm, Subject to change ETH
a
b
c
d
e
f
g
kg
31-0020-5E 31-0040-5E 35-0040-5E 35-0070-5E 35-0070-5E 36-0200-5E 36-0200-5E 35-0010-8D 35-0020-8D 36-0040-8D 36-0070-8D 36-0070-8D 36-0140-8D 36-0140-8D 37-0010-8D 37-0020-8D 37-0040-8D 37-0040-8D 37-0070-8D 37-0070-8D
155 155 155 200 225 155 200 225 225 302 200 200 225 225
200 200 200 254 305 200 254 305 305 385 254 254 305 305
150 150 150 170 165 150 170 165 165 223 170 170 165 165
144 144 144 194 265 144 194 265 265 350 194 194 265 265
98 98 98 140 188 98 140 188 188 265 140 140 188 188
6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2
30 30 30 30 30 30 30 30 30 30 30 30 30 30
4.0 4.0 4.0 8.0 17.0 6.0 8.0 14.0 20.0 35.0 5.5 8.0 14.0 20.0
Measurement diagram
1
2 3 4
f
5
0
d
b
a
32
c
g
e
Axial Flow Fans
Accessories
ETH
Speed setting transformatic, 5-step, with casing
Connection diagram
N
L1
PE N
L1
Mains
PE U1 U2 PE L1
N
PE U1 U2 PE L1
N
Motor
�
Connection diagram
N
L1
PE U1 U2 TK TK RT RT PE L1 N
11 12 14
PE N
L1
PE U1 U2
PE L1 N
11 12 14
�
Mains
Motor
Connection diagram
N
L1 L 2 L3 L3
PE U1 V1 W1 TK TK RT RT PE L1 N
11 12 14
PE N
L1 L2 L3
PE U1 V1 W1
PE L1 N
11 12 14
�
Mains
Motor
Connection diagram
N
L1 L 2 L3 L3
PE U1 V1 W1PTC PTC RT RT PE L1 N
11 12 14
PE N
L1 L2 L3
PE U1 V1 W1
PE L1 N
11 12 14
�
Mains
Motor
TK = Thermal contact contact of the motor PTC = Positive Temperature Temperature Coefficient (PTC-Thermistor) of the motor RT = Room thermostat or external switch = additional outlet e. g. for solenoid valve, lamp, etc. “Operating/Malfunction” = free contacts for the status signal “Operating/Malfunction”
33
Axial Flow Fans
Accessories
EPH
Transformer electronic, stepless
Design Shock-resistant plastic casing (creamwhite) in protection class IP 44, with turn knob on the front side. Clearly arranged terminal strip for mains and motor connection. For use as an integral v ersion in a standard switch box, the speedregulator with its front plate is simply removed from the casing underside.
Function The transformer contains contains a turn knob for the variation of the the nominal value by means means of phase-angle control, semiconductor fuse and a response output. The transformer EPH is not equipped equipped with any motor protection protection installation! If thermo contacts are in use it i s recommended to assure the electrical safety by installing motor protection units ESM 01-0020-5E.
Technical Data Nominal current A
Nominal voltage V
Frequency Hz
Fuse
EPH 03-0010-5E 03-0020-5E 03-0040-5E
1.0 2.0 4.0
230/240 230/240 230/240
50/60 50/60 50/60
F 1.0 A F 2.0 A F 4.0 A
Dimensions in mm, Subject to change EPH 03-0010/-0040-5E Surface mounting version
EPH 03-0010/-0020-5E flush mounting version Sealing
ø4
4 6
82
~65
24
Connection diagram
N N Re L
34
M N
32
Axial Flow Fans
Accessories
EPA EPA
Transformer electronic, stepless Electronic transformer with stepless adjustable output voltage for fans with controllable alternating current motors.
Design EPA 03-….-5E Completely plastic casing in protection class IP 54.
Function The Transformer Transformer EPA EPA 03 is equipped with a motor protection protection installation for thermal thermal contact connection, nominal value input, main switch, operating signal lamp, semiconductor fuses and adjustment options for minimal and maximal speed.
Technical Data EPA
Protection class max. current cons. IP A
Nominal voltage Frequency V Hz
app. Weight kg
03-0060-5E 03-0100-5E
54 54
230 230
1.3 1.9
0.2/- 6.0 0.2/-10.0
50/60 50/60
Dimensions in mm, Subject to change
241 213
122 0 3
7 5 3 8 1 1 0 1
0 6
198 5
Connection diagram
Max. contact capacity 5 A / 250 V AC Direct controller Input (Ri > 100k W ) PE PE PE L1 L1 N
PE
L1
Mains 1~ 230V 50/60Hz
N U1 U1
U2 U2
TK
U1
Z2
TK
Z1
U2
C in motor
12 11 14
TK
24V
10V
E
A
TK
GND
GND
GND
GND
1-phase motor with integrated thermo contacts
TK
U1
Z2
TK
Z1
U2
C in motor
1-phase motor with integrated thermo contacts
A B
1k �
+
+
N
J3
Input 0-10V
Output 0...10V (Imax=10mA)
35
Axial Flow Fans
Accessories
EPA EPA
Transformer electronic, stepless for voltage controlled single phase motor with capacitor winding
Design Speed regulator specially designed for control single phase fan drives. Noise reduced operation by high control frequency (19 kHz). Integrated power factor correction for sinus shaped feed current. Integrated radio noise filter to match EMC regulations.
Function Speed control: DC 0-10 V (through external potentiometer or external DC), can be switch to internal potentiometer (n min ). Minimum and maximum speed can be set (n min, nmax ). Pressure/temperature Pressure/temperature control: Digital input with ramp function to achieve a cheap control with pressure/temperature switches. Motor protection by current monitoring and connection of thermo contacts possible. Short circuit protected, automatic restarting device. Error messages: High temperature of controller, controller, thermo contact, short circuit, one relais output with switch over contact and reset button. Parametration possible via serial intersection for user specific use.
Connection and fitting Main 230 V, V, 50/60 Hz, fitted in vertical position. Output voltage: 10…98 % of input voltage. Radio noise suppression to EMC-Standard EN 50081-1, EN 50082-1. For cable length up to 10 m (shielded).
Recommendation We recommended the Nicotra Gebhardt pressure switch EIP 40, because the overall control precision depends on precision of the pressure switch.
Technical Data Protection class
Nominal current
input
max. power consumption
app. Weight
Operating temperature
EPA
IP
A
V
W
kg
°C
93-0023-5E
54
2.3
0-10
18
1.2
0 ... +40
Dimensions in mm, Subject to change 140
5 0 8 5 1 1
55
155
Connection diagram
1
L
N
2
3
Lm N1 R/L 4
5
6
7
8
9
10
A 0 1
36
PE
L
N
PE
U1 U1
p o t S
V 0 a 1 P +
V 0 1 . . . 0 +
21 22 23 24 25 26
Axial Flow Fans
Accessories
EPA EPA
Transformer electronic, stepless, digital Electronic controller for pressure, airspeed, temperature, with stepless adjustable output voltage for fans with controllable alternating current or threephase current motors respectively.
Design EPA 83 - Surface mounting version Plastic casing with die-cast aluminium base-plate in protection class IP 54.
Function The pressure controller controller EPA EPA 83 is equipped with a main switch, switch, a motor protection by thermal contact or PTC thermistors, nominal value input, main switch/automatic with bypass-function, actual value input for sensors with 0-10 V signal (Temperature (Temperature sensor EIT, Differential Differential pressure sensor EIP and Air velocity sensor EIL), for sensors with 4-20 mA signal; semiconductor fuses and adjustment options for minimal and maximal speed, menu-directed set-up via three function keys, output (0-10 V), potential-free operation signal contact, external nominal value preset via potentiometer, potentiometer, integrated semiconductor fuses, phase monitoring, controller block, reset pushbutton connection.
Technical Data Alternating current design design Protection class max. current cons. EPA IP A 83-0060-5E 83-0100-5E
54 54
0.2/- 6.0 0.2/-10.0
Nominal voltage Frequency app. Weight V Hz kg 230 230
50/60 50/60
1.6 2.6
Technical Data Three-phase current design Protection class max. current cons. EPA IP A 83-0050-8D 83-0100-8D 83-0150-8D 83-0250-8D
54 54 54 54
0.2/- 5.0 0.5/-10.0 0.5/-15.0 0.5/-25.0
Nominal voltage Frequency app. Weight V Hz kg 400 400 400 400
50/60 50/60 50/60 50/60
2.7 3.1 5.2 13.6
37
Axial Flow Fans
Accessories
EPA EPA
Transformer electronic, stepless, digital
Dimensions in mm, Subject to change EPA 83-0060-5E Surface mounting version
EPA 83-0100-5E Surface mounting version
140.5 115
128 213
240
102 0 3
7 5 3 8 1 1
4 5 6 2 2 2
0 1
0 6
5 . 5 ø
198 5
186
13
Dimensions in mm, Subject to change EPA 83-0050-8D Surface mounting version
EPA 83-0100-8D Surface mounting version
131 115
240
4 5 6 2 2 2
131 115
240
4 5 6 2 2 2
5 . 5 ø
186
5 . 5 ø
13
186
13
Dimensions in mm, Subject to change EPA 83-0150-8D Surface mounting version
EPA 83-0250-8D Surface mounting version
131 115
240
7 1 7 3
304 282 267
261 244
2 1
4 5 6 2 2 2
4 5 0 9 3 2 3 4 3 5 . 5 ø
186
38
13
ø9
Axial Flow Fans
Accessories
EPA EPA
Transformer electronic, stepless, digital
Connection diagram EPA 83-....-5E
Auto 0 100%
V
1 N I l a t i g i D
D-
Max. contact capacity 5 A / 250 V AC
D+
PE P E N
N L1 L 1 U1 U1 U 1 U 2 U 2 11 1 2 14 14
21 22 24
K1
24V
N L1
E 1. 1.1 E 1. 1. 2
1 T U O g o l a n A
2
2
1
N I l a t i g i D
N I g o l a n A
N I g o l a n A
TK
D1
A1
D2
E2
E1
TK
D1
GND
D2
GND
GND
DATA - GND RS485
1~ 230V 50/60Hz
E 2. 2.1 E 2. 2. 2 GND
1
Input
U1 U2 PE PE TK TK 1* If function is not needed, terminals must be bridged M 1~
Mains
mA
1*
K2
+
PE
°C
0...10 V (Ri>100 k) 0...20 mA 4...20 mA KTY10-6 (-8...+43°C)
2
Output 0...10 V (Imax=10 mA) 1-phase motor with integrated thermo contacts
Input 0...10 V (Ri>100 k) 0...20 mA 4...20 mA KTY10-6 (-24...+80°C)
Connection diagram EPA 83-....-8D
1 T U O g o l a n A
1 T U O C D V 4 2
D1
A
24V
D1
GND
24V
1 N I l a t i g i D
Max. contact capacity 5 A / 250 V AC GND N L 1 L2 L3 U
V W
11 14 12 21 24 22 K1
PE N L1 L2 L2 L3
Mains 1~ 230V 50/60Hz
U
V M 3~
W PE PE
TK TK
1
2
2
N I g o l a n A
N I g o l a n A
N I l a t i g i D
E1
E2
D2
GND
GND
°C
E2.1 E2.2
D2 E1.1 E1.2
V
DD+
mA
GND 24V
K2
1
Output
Input
0...10 V (Imax=10 mA)
0...10 V (Ri>100 k) 0...20 mA 4...20 mA KTY10-6 (-24...+80°C) 2
TK TK
3-phase motor with integrated thermo contacts
Input 0...10 V (Ri>100 k) 0...20 mA 4...20 mA KTY10-6 (-8...+43°C)
39
Axial Flow Fans
Accessories
ERA
Universal control device for installation in control cabinets Digital control module for controlling pressure, air velocity or volume flow (PI controller). For example, a transformer for fans is controlled via the 0-10 V output. The device is designed for installation in control cabinets.
Type Multi functional LC-display for actual and nominal values (m/s, hPa = mbar, mbar, 100 m³/h). Menuassisted adjustment via three function keys. Actual value input 0-10 V e. e. g. for: - air speed sensors Type EIL... in measuring ranges from 0-1 m/s and 0-10 m/s e. g. for: Air velocity control in clean room technology - Pressure sensors Type EIP... in measurement ranges 50-4000 Pa e. g. for: Pressure control in canal systems of air conditioning systems (VVS), Flow control in centrifugal fans with pressure tappings in the inlet cone.The control module calculates the required flow (m³/h) from the differential measured pressure between the surrounding level and inlet cone. - Output 0-10 V e. g. for controlling a transformer. - Failure message is output via display (internal/external) and relay programmable. - External set value s pecification via potentiometer or 0-10 V signal. - Specification of two set values (day/night), can be switched over externally or via keyboard. - Protection against unauthorised setting by keyboard code.
Application area - Pressure regulation for centralised ventilation systems and variable volume flow systems for building air conditioning (VVS) e.g. in combination with a frequency inverter or a commutation unit or a transformer and a pressure sensor. - Volume flow regulation for centrifugal fans (with measuring stub in the inlet cone) e.g. in combination with a frequency inverter or a commutation unit or a transformer or a mini-interface inverter and a pressure sensor and the volume flow volumeter. - Air speed regulation for clean room systems, e.g. in combination with a transformer and an air speed sensor.
Electrical connection and installation Connection to 230 V, V, 50/60 Hz. The control module can be installed in a control cabinet door. door. Admissible relative humidity: 85 %, noncondensing. Power supply for the sensors included: +24 V, ±20 %, I max = 70 mA.
Setting options
_
_
· V = K p = K 10 r2
p
– Set values in the measurement range of the sensor (m/s, hPa = mbar), or in the volume flow range of the fan (x 100 m³/h) – Switch over of set value (day/night) – Min./max. setting range – Translation of performance curve (P component) – Constant of integration can be selected (I component) – Reversal of the effect of the control behaviour – Rotation of the performance curve – Switchover or programming of internal/external set value – Sensor selection via keypad – Programming for ”Filter fault” – Keypad code – K factor entry (The K10-factor can be found in the current lists of our fan line)
Technical Data
40
Input
Out max.
ERA
V
mA
02-4000-5E
0...10
10
Protection class IP 20
Operating consumption
Operating temperature
VA
°C
< 10
0 ... +55
Axial Flow Fans
Accessories
ERA
Universal control device Dimensions in mm, Subject to change
6 0 1
166.5
44 max.
10.5
105
9 9
159
Instrument panel window
Connection diagram
°C V mA E2
1
2
3
4
5 °C V
(+) (+) (–) (–)
D+
24V
24V
D2
A1
GND
E1
L1 N PE
D–
GND
D1
D3
A2
GND
E2
mA E1
11 14 12 21 24 22 K1
Line
+ DATA A B GND GND RS485
A2
E2
4
K2
+
(Imax=10mA)
+
A1
E1
3
+
(Imax=10mA)
1 Out, 24 V DC 2 Input, Digital 1/2/3 3 Out, Analog 1/2 4 Input, Analog 0-10 V 1/2 5 Contact rating max. 5 A / 250 V AC
Out 0-10 V Out 0-10 V 3 Input 0-10 V 4 Input 0-10 V
41
Axial Flow Fans
Accessories
EIP
Differential pressure sensor Sensor with membrane for measuring the pressure, negative pressure or differential pressure of nonaggressive gases.
Type The differential differential pressure to be measured measured acts transformed transformed into an output signal of 0...10V by electronics (in SMD technology).
Application ranges Volume flow regulators regulators in centrifugal fans fans (with volume flow measuring measuring device IMV) in connection with a frequency inverter type G110, MM420, MM430, or a universal regulator appliance type ERA 02-4000-5E in connection with a frequency regulator Electrical connection and installation
The differential differential pressure sensor delivers a starting signal (0-10 V) by pressure pressure increase at the ”Plus” connection opposite pressure on the ”Minus” connection. Voltage supply: 15-30 V DC or 24 V AC, ±15 %. Pressure connections must point downward, tube connection ø5 mm.
Measuring accuracy Null drift: ±0.75 % Sum of linearity and hysteresis: ±1 % Temperature Temperature drift zero zero point: ±0.3 % / 10 K Temperature Temperature drift length length of measurement: measurement: ±0.2 % / 10 K
Technical Data Protection Protection type
EIP
Measuring range Pa
max. current consumption ca. mA
Overload protection Pa
Output signal prop. V DC
Operating temperature °C
20 21 22 23 24
0 - 200 0 - 500 0 - 1000 0 - 2000 0 - 4000
IP65 IP65 IP65 IP65 IP65
12 12 12 12 12
20000 20000 20000 20000 20000
0-10 0-10 0-10 0-10 0-10
0 bis +50 0 bis +50 0 bis +50 0 bis +50 0 bis +50
Dimensions in mm, Subject to change 50
70 5 , 4
0 0 5 . a c
ø5 8 16
Connection diagram Pressure connections Voltage supply Ø5 mm 15...30 V DC 24 V AC ±10 %
brown +
+~
�p
yellow
Output 0 ... 10V DC
�p
42
-
=
white ^
~
Axial Flow Fans
Accessories Time control module The time control module module ETG is for the implementation implementation of time-controlled time-controlled discharged air systems. With the time switch module ETG all fans with i ntegrated single phase AC motors (1~; 230 V; 50 Hz, 0...7 A) can be controlled. Allocation is via the motor nominal nominal current. The operating intervals can be freely programmed, programmed, and if required, required, the second pre-set pre-set speed stage can be changed. Programming the selected weekly cycle is possible by using up to 42 programmable switching points. The system is equipped with automatic automatic changeover between between summer and winter winter times, as well as integrated motor protection for motors with thermal contacts.
Technical Data Time switch module ETG for fans with single-phasen-AC motors 230 V; 50 Hz Controlling Nominal current ETG A 01-0018-5E 01-0040-5E 01-0070-5E
time time time
1.8 4.0 7.0
Dimensions in mm, Subject to change
0 0 3
300
170
43
Axial Flow Fans
Description General The axial flow fan line is suitable for conveying air or other gases or vapours which are not particularly aggressive. The minimum temperature for the conveying media is -30°C and the upper temperature limit is given with the data of the technical specification of each type. Flow direction “suction over motor flange”. Horizontal or vertical installation is possible.
Protection AQA 61, AWA 61 The axial flow fans are equipped with intake guard as a standard.
Guards for discharge are available as an accessory ARA 61, ARA 62, These fans are made for being integrated in a duct system or for wall flush mounting and are not supplied with an intake guard. If there is – by the way of installation or use the fan - no guard provided against a contact with the fan impeller the user has to ensure an appropriate protection according to DIN EN 294.
Matching guards and automatic back draught dampers (discharge side) are available as an accessory.
Accessories Every accessory has to be ordered separately. separately. Specification, technical data and dimensions see chapter “accessories”. The selection of the matching control units is specified wi th the table “Technical “Technical data”
Motoren The integrated motors are of protection class IP 44 or IP 54, - isolation class B, equipped with maintenance free deep grove ball bearings. They are selected for permanent operation S1 to VDE 0530. In order to protect them against thermal overload they are provided with thermo contacts. The thermo contact either protect the motor by direct switch off because of being fitted in series with the motor winding, or in connection with a motor protection unit. So overload of the motor will be safely prevented. Please check wiring diagrams. All motors are 100% speed controlled. The speed variation is caused by a voltage variation and a subsequent change of the rotational slip.
Elektrical wiring AWA 11 The fans of the line AWA 11- are supplied, as a standard, without terminal box. They are equipped with a free cable lead of about 450mm. The capacitor is supplied loose.
AQA 61, AWA 61, AT ATA 61, ARA 62 The fans of this line are supplied, as a standard, with a loose cable wired to a terminal box. For single phase units the capacitor is included.
ARA 61 This fan line has a terminal box fully wired and fitted on fan casing. For single phase units the capacitor is included. Each fan or service switch is provided with a wiring diagram The relevant wiring diagram may be found at:
www.nicotra-gebhardt.com
44
Axial Flow Fans
Description Performance data The performance data have been taken with a test rig according to DIN 24 163. . They show the pressure increase pfa of the fan as a function of the flow rate V for the arrangement free intake – free discharge. The data are valid for a density of the conveying media of r1 = 1.15 kg/m³.
Sounds The fan curves include the a-weighted sound power data for free intake LWA5 according to DIN EN 25 136. They differ from the total sound power by having been Aweighted. The data have been taken according to DIN EN 25136 suction side by applying the envelope method. The weighted sound pressure data Lpa for a distance of 1m from intake can be approximately calculated by subtracting 7 dB from the A-sound-power value. Attention must be given to the ambient acoustical conditions, duct connections, resonances, reflections, etc. which may have an influence on the sound properties of the system. The sound power levels in the octave bands are taken as follows: The relative sound power levels for the duty point – free intake – can be taken from the table below.
Determination of the Octave level
Fan type 10Fan type 60-
fm
63
125
250
500
1000
2000
4000
8000
Hz
LWrel LWrel
15 15
14 4
4 4
4 4
8 6
5 6
10 11
15 21
dB dB
45
s e t o N / s n o i t p i r c s e D
Axial Flow Fans
Notes Quality management system DIN EN ISO 9001 Nicotra Gebhardt quality is the result of rigorously pursuing business policy goals, which specify that Nicotra Gebhardt products must display properties and characteristics that are clearly above average when compared to similar products. This maxim, which has applied since since the company was founded, founded, lead in April 1985 to the auditing and certification of the existing quality assurance system. In subsequent years, it was adjusted to comply with changed international and European standards. Modern production procedures, monitored by our quality management system, ensure a high level of repeatability in manufacturing. The tight tolerances allow high high levels of data security for our our products.
Information on machine safety The fans listed in this catalogue catalogue are classified as not automatically operable mamachines in terms of the EC machine guideline 98/37/EC, and shall therefore be given a manufacturer’s declaration. A CE mark with regard to the low-voltage guideline will be given. The assessment of danger danger arising from the fan and requisite safety measures measures occuroccurred resulting from the VDMA (Association of German Mechanical Engineering Institutions) standard sheet 24 167: Fans; safety requirements. The Operating Instructions give give which safety measures measures are still necessary on assemassembly to ensure that the fans comply with the EU Machine Guideline 98/37/EG.
Notes on catalogue data We reserve the right to change the dimensions and technical data contained in this catalogue in the event that our product is further developed. All details correspond to the version on the date of printing.
General Delivery and Payment Conditions (DPC) Our General Delivery and Payment Conditions (DPC) are online at www.nicotrawww.nicotragebhardt.com.
46
Axial Flow Fans
Notes Service Our mobile service offer for intervention on the site in combination with our standby team at the workshop will assure an efficient support to all requirements you may have. Make just a phone call and our service team will help you to solve your problem fast and reliably.
Service Hotline
Phone Fax
+49 (0)7942 / 101-384 +49 (0)7942 / 101-385
The part shop offered by Nicotra Gebhardt The easy-to-handle online shop enables you to identify instantly every spare part. part. A graphically supported list makes your selection easy. So an online service is available which will help you to make your repair as simple as possible.
www.nicotra-gebhardt.com
47
e g i e t S / n e g n i l s i e G , g a l r e V d n u k c u r D R E R U A M . C y b y n a m r e G n i d e t n i r P – 9 0 0 2 . 7 0 0 0 0 0 – 6 . 3 F F A N E
Nicotra Gebhardt GmbH
48
Nicotra Gebhardt S.p.A
Gebhardtstrasse 19-25 74638 Waldenburg Germany
Via Modena, 18 24040 Zingonia (Bergamo) Italy
Telephone Telephone +49 (0)7942 101 0 Telefax Telefax +49 (0)7942 101 170 E-Mail
[email protected]
Telephone Telephone +39 (0)35 873 111 Telefax Telefax +39 (0)35 884 319 E-Mail
[email protected]
www.nicotra-gebhardt.com
www.nicotra-gebhardt.com