Nicotra Axial Fans

March 25, 2019 | Author: Anonymous 1uQrCTY | Category: Mechanical Fan, Manufactured Goods, Electricity, Technology, Energy Technology
Share Embed Donate


Short Description

fans...

Description

 Axial Flow Fans Fan s Issue 6

1

 Axial Flow Fans

 Axial Flow Fans  Axial Flow Fans

Content 4– 5 6 – 13 14 – 17 18 – 21 22 – 23 24 – 43 44 – 45 46 – 47

2

 Technical  Technical data Curves Dimensions Specifications Samples  Accessories Description Notes

 Axial Flow Fans

 Axial Flow Fans High Performance - Axial Flow Fans  AQA 61-0315/-0630 Square wall mounting plate incorporating an inlet ring of galvanised sheet steel and painted. (light grey) Plastic impeller bolted to the rotor of the i ntegral motor, motor, Connecting cable and terminal box supplied loose Inlet guard fitted conforming to DIN EN 294. Low noise, maintenance free, ready to connect

 Application: General ventilation, Cooling industry, Farming and glass house ventilation

High Performance - Axial Flow Fans  AWA 11-0200/-0300 11-0200/-0300 Wall mounting ring incorporating an inlet cone of painted sheet steel. Impeller made from galvanised sheet steel shrink-fitted onto the rotor of the integral motor, Connection cable supplied loose Inlet guard fitted conforming to DIN EN 294. Low noise, maintenance free, ready to connect

 Application: General ventilation, Cooling industry, Farming and glass house ventilation

 AWA 61-0315/-0630 61-0315/-0630 Wall mounting ring incorporating an inlet cone of galvanised sheet steel and painted. (light grey) Plastic impeller bolted to the rotor of the i ntegral motor, motor, Connecting cable and terminal box supplied loose Inlet guard fitted conforming to DIN EN 294. Low noise, maintenance free, ready to connect

 Application: General ventilation, Cooling industry, Farming and glass house ventilation

High Performance - Axial Flow Fans  ARA 61-0315/-0630 Duct mounted casing with connecting flanges on both sides, made from sheet steel and powder coated Plastic impeller bolted to the rotor of the i ntegral motor, motor, Low noise, maintenance free, ready for connection with terminal box fitted on fan casing

 Application: General ventilation, Cooling industry, Farming and glass house ventilation

 ARA 62-0315/-0630 Duct mounted for flush mounting in long casing design, made from sheet steel and powder coated Plastic impeller bolted to the rotor of the i ntegral motor, motor, Low noise, maintenance free, ready for connection with terminal box fitted on fan casing

 Application: General ventilation, Cooling industry, Farming and glass house ventilation

High Performance - Axial Flow Fans  ATA  ATA 61-0315/-0630 61-0315/-0630  Technical  Technical design as for AWA and AQA but without wall ring, suitable to be integrated into units. Self supporting inlet guard fitted conforming to DIN EN 294. Low noise, maintenance free, ready to connect

 Application: General ventilation, Cooling industry, Farming and glass house ventilation

3

 Axial Flow Fans

 Axial Flow Fans Technical Data

 AWA 1111-

Fan speed 1/min

Nominal motor voltage V

max. power consumption kW

Nominal motor current A

Capacitor µF

max. Media temperature °C

0200–2E 0200–4S 0250–2E 0250–4S 0300–2E 0300–4E

2650 1315 2500 1350 2550 1340

230 230 230 230 230 230

0.065 0.039 0.130 0.065 0.180 0.095

0.32 0.32 0.68 0.52 0.85 0.46

2 – 4 – 6 3

70 50 55 45 50 50

Weight appr. appr. kg 3 2 3.5 3 4.5 4.5

Technical Data

 AQA 61

AWA 61

ARA 61

Fan speed 1/min

Nominal motor voltage V

max. power consumption kW

Nominal motor current A

0315–4D 0315–6D  0315–6D   0315–4E 0315–6E

1350 940 1405 925

230/400 230/400 230 230

0.11 0.07 0.11 0.06

0355–4D 0355–6D  0355–6D   0355–4E 0355–6E

1400 960 1340 920

230/400 230/400 230 230

0400–4D 0400–6D  0400–6D   0400–4E 0400–6E

1350 950 1320 935

0450–4D 0450–6D 0450–4E 0450–6E

ARA 62 Capacitor

ATA ATA 61

µF

max. Media temperature °C

Weight appr. appr. kg AQA AWA

ATA ATA

ARA 

0.66/0.38 0.48/0.28 0.65 0.3

– – 3 2

45 45 50 50

5 5 5 5

4.5 4.5 4.5 4.5

3.5 3.5 3.5 3.5

5.7 5.7 5.7 5.7

0.18 0.09 0.16 0.07

0.78/0.45 0.52/0.3 0.95 0.4

– – 4 2

40 45 50 50

6 6 6.5 6.5

5.5 5.5 6 6

4 4 4.5 4.5

6.4 6.4 6.8 6.8

230/400 230/400 230 230

0.2 0.11 0.22 0.1

1.21/0.7 0.93/0.54 1.15 0.6

– – 6 3

50 50 45 60

9 9 9 9

8 8 8 8

6 6 6 6

8.8 8.8 9 9

1350 925 1290 935

230/400 230/400 230 230

0.3 0.16 0.35 0.18

1.37/0.79 1.18/0.68 1.9 1.15

– – 8 6

50 50 40 45

12 12 13 13

11 11 12 12

7.5 7.5 8 8

10.5 10.5 11 11

0500–4D 0500–6D 0500–4E 0500–6E

1440 960 1340 940

230/400 230/400 230 230

0.6 0.22 0.57 0.26

2.86/1.65 1.47/0.85 3.15 1.6

– – 16 10

50 55 50 50

18 17 18 18

16 15 16 16

12 10.5 12 12

14 14 16 16

0560–4D 0560–6D  0560–6D   0560–4E 0560–6E

1320 960 1330 960

230/400 230/400 230 230

1.19 0.45 1.3 0.59

4.47/2.58 2.9/1.7 6.25 3.2

– – 25 20

40 60 40 50

28 28 33 33

26 26 31 31

20 20 23 23

23 23 28 28

0630–4D 0630–6D 0630–6E

1320 945 945

230/400 230/400 230

1.65 0.58 0.7

5.54/3.2 3.2/1.85 3.5

– – 25

45 60 50

40 35 40

36 31 36

26 21 26

33 28 33

 The motors are equipped with thermo contacts to prevent them against thermal overload. Each fan or service switch is provided with a wiring diagram  The relevant wiring diagram may be found at:

www.nicotra-gebhardt.com

4

 Axial Flow Fans

 Axial Flow Fans Technical Data

 AWA 1111-

Motor protection unit ESM 

Transformer Transformer 7 taps ETO

Transformer Transformer 5-steps ETH 

Speed regulator electronic EPH

Speed regulator electronic EPA

Speed regulator micro processor EPA

Speed controller electronic EPA 

0200-2E 0200-4S 0250-2E 0250-4S 0300-2E 0300-4E

– – – – – –

10-0018-5E 10-0018-5E 10-0018-5E 10-0018-5E 10-0018-5E 10-0018-5E

31-0020-5E 31-0020-5E 31-0020-5E 31-0020-5E 31-0020-5E 31-0020-5E

03-0010-5E 03-0010-5E 03-0010-5E 03-0010-5E 03-0010-5E 03-0010-5E

03-0060-5E 03-0060-5E 03-0060-5E 03-0060-5E 03-0060-5E 03-0060-5E

93-0023-5E 93-0023-5E 93-0023-5E 93-0023-5E 93-0023-5E 93-0023-5E

83-0060-5E 83-0060-5E 83-0060-5E 83-0060-5E 83-0060-5E 83-0060-5E

 

Motor protection unit ESM 

Transformer Transformer 7 taps ETO

Transformer Transformer 5-steps ETH 

Speed regulator electronic EPH

Speed regulator electronic EPA

Speed regulator micro processor EPA

Speed controller electronic EPA 

0315-4D 0315-6D 0315-4E 0315-6E

01-0040-8D 01-0040-8D 01-0020-5E 01-0020-5E

10-0010-8D 10-0010-8D 10-0018-5E 10-0018-5E

35-0010-8D 35-0010-8D 31-0020-5E 31-0020-5E

– – 03-0010-5E 03-0010-5E

– – 03-0060-5E –

– – 93-0023-5E 93-0023-5E

83-0050-8D – 83-0060-5E 83-0060-5E

0355-4D 0355-6D 0355-4E 0355-6E

01-0040-8D 01-0040-8D 01-0020-5E 01-0020-5E

10-0010-8D 10-0010-8D 10-0018-5E 10-0018-5E

35-0010-8D 35-0010-8D 31-0020-5E 31-0020-5E

– – 03-0010-5E 03-0010-5E

– – 03-0060-5E 03-0060-5E

– – 93-0023-5E 93-0023-5E

83-0050-8D 83-0050-8D 83-0060-5E 83-0060-5E

0400-4D 0400-6D 0400-4E 0400-6E

01-0040-8D 01-0040-8D 01-0020-5E 01-0020-5E

10-0010-8D 10-0010-8D 10-0018-5E 10-0018-5E

35-0010-8D 35-0010-8D 31-0020-5E 31-0020-5E

– – 03-0020-5E 03-0010-5E

– – 03-0060-5E 03-0060-5E

– – 93-0023-5E 93-0023-5E

83-0050-8D 83-0050-8D 83-0060-5E 83-0060-5E

0450-4D 0450-6D 0450-4E 0450-6E

01-0040-8D 01-0040-8D 01-0020-5E 01-0020-5E

10-0010-8D 10-0010-8D 10-0040-5E 10-0018-5E

35-0010-8D 35-0010-8D 31-0020-5E 31-0020-5E

– – 03-0020-5E 03-0020-5E

– – 03-0060-5E 03-0060-5E

– – 93-0023-5E 93-0023-5E

83-0050-8D 83-0050-8D 83-0060-5E 83-0060-5E

0500-4D 0500-6D 0500-4E 0500-6E

01-0040-8D 01-0040-8D 01-0020-5E 01-0020-5E

10-0020-8D 10-0010-8D 10-0040-5E 10-0018-5E

35-0020-8D 35-0010-8D 35-0040-5E 31-0020-5E

– – 03-0040-5E 03-0020-5E

– – 03-0060-5E 03-0060-5E

– – – 93-0023-5E

83-0050-8D 83-0050-8D 83-0060-5E 83-0060-5E

0560-4D 0560-6D 0560-4E 0560-6E

01-0040-8D 01-0040-8D 01-0020-5E 01-0020-5E

10-0040-8D 10-0020-8D 10-0070-5E 10-0040-5E

36-0040-8D 35-0020-8D 35-0070-5E 35-0040-5E

– – – 03-0040-5E

– – 03-0100-5E 03-0060-5E

– – – –

83-0050-8D 83-0050-8D 83-0100-5E 83-0060-5E

0630-4D 0630-6D 0630-6E

01-0040-8D 01-0040-8D 01-0020-5E

10-0040-8D 10-0020-8D 10-0040-5E

36-0040-8D 35-0020-8D 35-0040-5E

– – 03-0040-5E

– – 03-0060-5E

– – –

83-0050-8D 83-0050-8D 83-0060-5E

   a    t    a    D    l    a    c     i    n    h    c    e    T

Technical Data

 Motor protection unit is not required.  The thermo contacts are fitted in series with the motor winding. They switch the motor off directly when a thermal overload occurs and they switch it on automatically after cooling down.  An extra motor protection unit is not required when using speed control units of the types ETH 32-, ETH 36-, and EPA 03-. These control units are already equipped with a motor protection unit.

5

 Axial Flow Fans

 AWA  AWA 11-0200/-0250/-0300 11-0200/-0250/-0300 Curves

r1 = 1.15 kg/m³

Pa

0200-2E

250

Pa

speed controllable

� 150

 

100

60

� = 230 V  = 190 V  = 165 V  = 145 V  = 125 V  = 105 V  = 85 V

200

0200-4S speed controllable

50

� = 230 V  = 190 V  = 165 V  = 145 V  = 125 V  = 105 V  = 85 V

�  

40

 30



W     A  5   

 

      a        f

     � 0 100

200

6    8   

6  1 

5 2  0

L  

W      A    5   

L  

50

      p



20



300

400

0.  V 

500

600

700

0.1

10

=   7    3    d    B   

      a        f

      p

800 m³/h

0

speed controllable

50

100

150

0.  V 

m³/s

0250-2E

240

5    3   

�0

0.2

Pa



200

250

300

=   5    8    d     B   

350

0.05

400 m³/h

0.1

Pa

m³/s

0250-4S

100

speed controllable

90

� = 230 V  = 190 V  = 165 V  = 145 V  = 125 V  = 105 V  = 85 V

200

� 160



120

70

50

      p

W      A    5   

200

400

0.  V 

7    2  

6  1 

     � 0 0



30

L  

  

      a        f

 

40



40



60

 80

 = 230 V  = 190 V  = 165 V  = 145 V  = 125 V � = 105 V  = 85 V

80

600

0. 1

800

1000

0.2

1200

      p

0.4

m³/s

0300-2E

250

W     A  5   

6  0  

4 8 

     � 0

1600 m³/h

Pa

L  



10

      a        f

1400

0. 3

 �

20

=   7    9    d    B   

0

100

200

300

0.  V 

400

500

600

0.1

700

800

900 m³/h

0.2

m³/s

Pa

0300-4E

140

speed controllable � = 230 V  = 190 V  = 165 V  = 145 V  = 125 V  = 105 V  = 85 V

200

� 150

 

100

speed controllable

 80



W     A  5   

      p

7  3  

6  1 

     � 0 0 0.  V 

500 0.1

1000 0.2

 Volume flow

1500

0. 3

0.4

2000 0.5

0.6



40

L  

 

      a        f



100

60



=   8    0    d    B    2500 m³/h 0.7 m³/s

� = 230 V  = 190 V  = 165 V  = 145 V  = 125 V  = 105 V  = 85 V

120



50



L  

W      A    5   

 

20       a        f

      p

0 0.  V 

200

400 0. 1

600

800 0.2

provent 

LWA5 at V· max dB

Folume flow V· in m3 /h at available pressure increase pfa in Pa 0 10 20 40 60

0200–2E 0200–4S 0250–2E 0250–4S 0300–2E 0300–4E

2650 1315 2500 1350 2550 1340

73 58 79 65 80 71

790 390 1570 860 2460 1720

360 800 1650

6    3   

5  5  

     � 0

Fan Speed 1/min

6

=   6    5    d    B   

740 310 1490 720 2300 1575

1000

1200

0.3

=   7     1    d     B   

1400

1600 1800 m³/h

0.4

0.5 m³/s

r1 = 1.15 kg/m³

80

100

120

690

640

575

490

1420 480 2180 1400

1330

1230

1120

970

2020 1150

1850

1650

1350

 Axial Flow Fans

Size 0315 Curves

r1 = 1.15 kg/m³

Pa

0315-4D

Pa

0315-6D

speed controllable

100

speed controllable 45

 = 400 V  = 330 V  = 285 V  = 250 V  = 215 V � = 180 V  = 150 V

90

80



70

40

� 35



 

30





60

 50

� = 400 V  = 330 V  = 285 V  = 250 V  = 215 V  = 180 V  = 150 V

25



 

20

   s    e    v    r    u     C



40

15



30

10

20

L     

W         A       5      

L     

W         A       5      

10       a        f

6      1    

      p

     � 0 0

200

400

0.  V 

600

0. 1

800

1000

0. 2

1200

0. 3

6       5     

5

=     6       9       d       B      

5     5    

      p

     � 0

1400

1600 1800 m³/h

0.4

0.5 m³/s

Pa

5      8     

      a        f

0315-4E

0

200

400

0.  V 

600

800

0. 1

m³/h

1000

0.2

0.3 m³/s

Pa

0315-6E

speed controllable

100

=     6        1       d        B      

speed controllable 45

 = 230 V  = 190 V  = 165 V  = 145 V  = 125 V � = 105 V  = 85 V

90

80

 

70

40



35

 

30



60

 = 230 V  = 190 V  = 165 V  = 145 V  = 125 V � = 105 V  = 85 V





25



50



20



40



15

30





10

20

L    

W        A      5     

L    

W       A     5     

10       a        f

5    8   

      p

     � 0 0

200

0.  V 

400

600

0. 1

 Volume flow

800

1000

6       5     

1200

0. 3

0. 2

5

=    6      9      d      B    

      a        f

5    0   

      p

     � 0

1400

1600 1800 m³/h

0.4

0.5 m³/s

0

200

0.  V 

400

1000

0.2

provent 

LWA5 at V· max dB

Folume flow V· in m3 /h at available pressure increase pfa in Pa 0 10 20 30 40

0315–4D 0315–6D  0315–6D   0315–4E 0315–6E

1350 940 1405 925

69 61 69 61

1680 1170 1700 1160

1500 815 1470 800

800

0. 1

Fan Speed 1/min

1600 1040 1600 1025

600

5     5    

=    6       1      d       B      m³/h

0.3 m³/s

r1 = 1.15 kg/m³

50

1360

1200

1000

1340

1190

990

60 780

7

 Axial Flow Fans

Size 0355 Curves

r1 = 1.15 kg/m³

Pa

0355-4D

Pa

0355-6D

speed controllable

speed controllable

 = 400 V  = 330 V  = 285 V  = 250 V  = 215 V � = 180 V  = 150 V

120

100

80

50

40

  

  



60

 = 400 V  = 330 V  = 285 V  = 250 V  = 215 V � = 180 V  = 150 V

60

30





� 20



40





L    

W        A      5     

20

      a        f

6      8    

6      1    

      p

     � 0 0 0.  V 

500 0.1

1000 0.2

0.3

1500 0. 4

2000 0.5

0. 6

Pa

L    

10

=    7       2      d       B     

W        A      5     

      a        f

5      6     

      p

     � 0

2500

m³/h

0

0.7

m³/s

0.  V 

0355-4E

200

400

600

0. 1

800 0.2

1000

1200

0.3

6      0     

1400

1600 1800 m³/h

0.4

0.5 m³/s

Pa

0355-6E

speed controllable

110

speed controllable

 = 230 V  = 190 V  = 165 V  = 145 V  = 125 V � = 105 V  = 85 V

100

90 80

� 

40

 

 

60

� = 230 V  = 190 V  = 165 V  = 145 V  = 125 V  = 105 V  = 85 V

50

 70

=    6      4      d      B     



30

 50

 

40

30

20





20

W         A       5      

10       a        f

5    5   

      p

     � 0 0 0.  V 

500 0.1

10

L     



1000 0.2

 Volume flow

0.3

6      6     

1500 0. 4

2000 0.5

0. 6

=     7       1       d       B      

L    

W        A      5     

      a        f

5      4     

      p

     � 0

2500

m³/h

0

0.7

m³/s

0.  V 

200

400 0. 1

600

800 0.2

provent 

Fan Speed 1/min

LWA5 at V· max dB

Folume flow V· in m3 /h at available pressure increase pfa in Pa 0 10 20 30 40

0355–4D 0355–6D 0355–4E 0355–6E

1400 940 1340 920

72 64 71 64

2870 1900 2700 1880

8

2750 1700 2570 1700

2600 1500 2430 1470

2450 1150 2300 1140

2300 2100

1000

1200

0.3

6      0     

=    6      4      d      B     

1400

1600 1800 m³/h

0.4

0.5 m³/s

r1 = 1.15 kg/m³

50

60

2150

1850

 Axial Flow Fans

Size 0400 r1 = 1.15 kg/m³

Curves Pa

0400-4D

Pa

0400-6D

speed controllable 140

speed controllable 70

 = 400 V  = 330 V  = 285 V  = 250 V  = 215 V � = 180 V  = 150 V

120

100

60



50



 

 80

� = 400 V  = 330 V  = 285 V  = 250 V  = 215 V  = 180 V  = 150 V

 

40

 





60

30



� 40

20



L     

W         A       5      

20       a        f

6     4    

      p

     � 0 0 0.  V 

500

1000

0. 1

0. 3

0.2

1500 0. 4

2000 0. 5

6      9     

2500

0. 6

0.7

3000 0. 8

L     

0. 9

Pa

10

=     7       3       d       B      

3500

W         A       5      

      a        f

     � 0 m³/h

0

1.0 m³/s

0400-4E

0.  V 

500 0.1

1000 0.2

0. 3

1500 0.4

0.5

0.6

Pa

0.7 m³/s

0400-6E speed controllable 70

� = 230 V  = 190 V  = 165 V  = 145 V  = 125 V  = 105 V  = 85 V

120

2500 m³/h

2000

speed controllable 140

6      3    

5     9    

      p

=     6       6       d       B      

 = 230 V  = 190 V  = 165 V  = 145 V  = 125 V � = 105 V  = 85 V

60

100

50





 

80

 

40







60

30



� 20

40

 

L     



20

W         A       5      

      a        f

5    9   

      p

     � 0 0 0.  V 

500 0. 1

1000 0.2

0. 3

 Volume flow

1500 0. 4

6      8    

2000 0. 5

2500

0. 6

0.7

3000 0. 8

0. 9

L     

10

=     7       3       d       B      

3500

W         A       5      

      a        f

5    5   

      p

     � 0 m³/h

1.0 m³/s

0 0.  V 

500 0.1

1000 0.2

0. 3

provent 

Fan Speed 1/min

LWA5 at V· max dB

Folume flow V· in m3 /h at available pressure increase pfa in Pa 0 10 20 30 40

0400–4D 0400–6D 0400–4E 0400–6E

1350 950 1320 935

73 66 73 66

3580 2500 3550 2450

3450 2300 3400 2260

3300 2100 3250 2050

3140 1800 3110 1740

6      3    

1500 0.4

2000 0.5

0.6

=     6       6       d       B       2500 m³/h 0.7 m³/s

r1 = 1.15 kg/m³

50

60

70

2975

2800

2500

2000

2900

2750

2400

2000

9

 Axial Flow Fans

Size 0450 Curves

r1 = 1.15 kg/m³

Pa

0450-4D

Pa

0450-6D

speed controllable

speed controllable

180

90

 = 400 V  = 330 V  = 285 V  = 250 V  = 215 V � = 180 V  = 150 V

160

140

 = 400 V  = 330 V  = 285 V  = 250 V  = 215 V � = 180 V  = 150 V

80

70

120



60

  

100

 

50



 40

80



 60

30

� 

40



20

L      

L      

W         A       5       

20       a        f

6     7    

      p

     � 0 0

1000

2000

0.  V 

7      3    

3000

0. 5

4000

=     7        8        d        B       

1.0

10       a        f

     � 0 0

1.5 m³/s

Pa

0450-4E

6      0    

      p

m³/h

5000

W          A        5       

1000

2000

0.  V 

6      7     

=     7        0        d         B        4000 m³/h

3000

0.5

1.0

Pa

m³/s

0450-6E

speed controllable

speed controllable

180

90

� = 230 V  = 190 V  = 165 V  = 145 V  = 125 V  = 105 V  = 85 V

160

140

 = 230 V  = 190 V  = 165 V  = 145 V  = 125 V � = 105 V  = 85 V

80

70

� 120

60



 100



80

40



60



30



40

 

50



� 20





L      

W         A       5       



20       a        f

6     9    

5     9   

      p

     � 0 0

1000

0.  V 

2000

3000

0. 5

 Volume flow

4000

=     7        8        d        B       

1.0

10       a        f

     � 0 0

1000

2000

0.  V 

1.5 m³/s

provent 

LWA5 at V· max dB

Folume flow V· in m3 /h at available pressure increase pfa in Pa 0 10 20 30 40 50

0450–4D 0450–6D 0450–4E 0450–6E

1350 925 1290 935

78 70 78 70

5450 3830 5500 3800

10

3600

5150 3400 5200 3400

3100 3100

4750 2780 4860 2800

=     7        0        d         B        4000 m³/h

3000

0.5

Fan Speed 1/min

3620

6      5     

5     6    

      p

m³/h

5000

L      

W          A        5       

1.0

m³/s

r1 = 1.15 kg/m³

60

70

80

90

4350

3800

3450

4480

4000

3600

2000

 Axial Flow Fans

Size 0500 Curves

r1 = 1.15 kg/m³

Pa

0500-4D speed controllable

240

� = 400 V  = 330 V  = 285 V  = 250 V  = 215 V  = 180 V  = 150 V

220 200 180

� 160

Pa

110

 = 400 V  = 330 V  = 285 V  = 250 V  = 215 V � = 180 V  = 150 V

100

90



80

 

140

0500-6D speed controllable

  

70

 �

60 120



50



100



40

80

30

60

L      

L      

W         A       5       

40 20       a        f

7      8    

7     3    

      p

     � 0 0

1000

2000

3000

0.  V 

4000

5000

6000

1.0

20

=     8        1       d        B       

7000

8000 m³/h

2.0

m³/s

Pa

0500-4E speed controllable

220

� = 230 V  = 190 V  = 165 V  = 145 V  = 125 V  = 105 V  = 85 V

200

180

160

140

10       a        f

     � 0 0

1000

2000

0.  V 

3000

0. 5

4000 1.0

=     7        2        d        B        m³/h

5000

1.5 m³/s

Pa

0500-6E speed controllable

110

� = 230 V  = 190 V  = 165 V  = 145 V  = 125 V  = 105 V  = 85 V

100

90

� 80



70



 

60



 100

7      0     

6      7     

      p



120

W         A       5       

50



80



40

 60

30



 40

 20       a        f

7     3    

6     2   

      p

     � 0 0

1000

20

L      

W          A        5       

2000

3000

0.  V 

4000

5000

1.0

 Volume flow

6000

L      

W         A       5       

=     8        0        d         B       

10       a        f

     � 0

7000

8000 m³/h

2.0

m³/s

0

1000

0.  V 

2000

provent 

Folume flow V· in m3 /h at available pressure increase pfa in Pa 0 20 40 60 80

0500–4D 0500–6D 0500–4E 0500–6E

1440 960 1340 940

81 72 80 71

8600 5800 8050 5550

7580 3850 6950 3400

4000

5000

1.0

LWA5 at V· max dB

7900 4700 7350 4500

3000

0. 5

Fan Speed 1/min

8290 5300 7700 5100

6      8    

6     0    

      p

=     7        1       d        B        m³/h

1.5 m³/s

r1 = 1.15 kg/m³

100

120

140

7100

6650

6000

4500

6500

5900

5000

11

 Axial Flow Fans

Size 0560 Curves

r1 = 1.15 kg/m³

Pa

0560-4D

Pa

0560-6D

speed controllable � = 400 V  = 330 V  = 285 V  = 250 V  = 215 V  = 180 V  = 150 V

240

200



speed controllable 140

 = 400 V  = 330 V  = 285 V  = 250 V  = 215 V � = 180 V  = 150 V

120



100



160



   �

80

 120





60

 80 40



L        

W            A          5          

40

      a        f

7        7       

7      3    

      p

L      

=     8         4           d           B          

W          A        5        

20       a        f

     � 0

     � 0 0

2000

0.  V 

4000

6000

8000 2. 0

1.0

10000

12000

m³/h

0

m³/s

0.  V 

3. 0

Pa

0560-4E

7      4     

7      0     

      p

2000

4000

6000

1.0

 = 230 V  = 190 V  = 165 V  = 145 V  = 125 V � = 105 V  = 85 V

200



2.0

m³/s

Pa

0560-6E speed controllable

140

 = 230 V  = 190 V  = 165 V  = 145 V  = 125 V � = 105 V  = 85 V

120

 100



   

160



80



120



80

60





40

L      

L        

W          A        5        

W            A          5          

� 40

 7      9     

7     2    

6    2   

      a        f

=     8         4           d           B          

=     7         6         d         B        

20

      p

7      1    

6      5    

      a        f

      p

     � 0

     � 0 0 0.  V 

2000

4000

6000

1.0

 Volume flow

8000 2. 0

10000 3. 0

12000

m³/h

0

m³/s

0.  V 

2000

4000

provent 

Folume flow V· in m3 /h at available pressure increase pfa in Pa 0 20 40 60 80 90

0560–4D 0560–6D 0560–4E 0560–6E

1320 960 1330 960

84 76 84 76

12500 8900 13000 9100

8600

11700 7900 12200 8000

7250 7300

10800 6200 11300 6400

8000 2.0

LWA5 at V· max dB

8400

6000

1.0

Fan Speed 1/min

12

m³/h

8000

speed controllable 240

=     7         6         d         B        

5700

m³/h m³/s

r1 = 1.15 kg/m³

120

160

9900

8150

10300

9000

180

7900

 Axial Flow Fans

Size 0630 Curves

r1 = 1.15 kg/m³

Pa

0630-4D speed controllable

280

� = 400 V  = 330 V  = 285 V  = 250 V  = 215 V  = 180 V  = 150 V

240



Pa

0630-6D

160

speed controllable

140

� 120



200





100

 



160

� = 400 V  = 330 V  = 285 V  = 250 V  = 215 V  = 180 V  = 150 V

80



 120 60







80

40



L      

L      

W          A        5        

W          A        5        

=     8       8       d         B      

40       a        f

8      3     

7     4    

      p

     � 0 0

2000

0.  V 

4000

6000

1.0

8000

      a        f

7     2    

      p

     � 0

10000 12000 14000 16000 m³/h 3.0

2.0

4.0

=     8         1         d         B        

20

0

m³/s

2000

4000

0.  V 

6000

1. 0

7         7        

8000

m³/h

10000

2.0

3.0 m³/s

Pa

0630-6E

160

speed controllable � = 230 V  = 190 V  = 165 V  = 145 V  = 125 V  = 105 V  = 85 V

140

120

� 

100

 

80



60

 40



L      

W          A        5        

20       a        f

     � 0 0

2000

0.  V 

 Volume flow

4000

6000

1. 0

provent 

LWA5 at V· max dB

Folume flow V· in m3 /h at available pressure increase pfa in Pa 0 20 40 60 80 90

0630–4D 0630–6D 0630–6E

1320 945 945

88 81 80

16550 11500 11400

15550 10300 10100

9500 9300

14550 8200 8000

8000

10000

2.0

Fan Speed 1/min

11000 10750

7      6     

6     6    

      p

=     8         0         d         B         m³/h

3.0 m³/s

r1 = 1.15 kg/m³

120

160

180

13450 7150 7000

13

 Axial Flow Fans

 AWA  AWA 11-0200/-0300  AWA  AWA 61-0315/-0630 Dimensions in mm, subject to change  AWA 11- 0200/ -0250 AWA 11- 0300 b3 b4

b3 b4

a 1

  d  4   ø

a   

2   

   3    d   1    2    d    d   ø   ø   ø

   2    d   1    d   ø   ø

 ø e

b5 b2

b2

 AWA  AWA 11-

b2

b3

b4

b5

ød1

ød2

ød3

ød4

øe

1

2

0200– 0250– 0300–2E 0300–4E

6 6 11 11

89 94 89 89

75 79 69 69

– – 12 2

280 320 397 397

200 254 306 306

– – 326 326

7 7 9 9

250 295 380 380

15° 15° 15° 15°

6×60° 6×60° 6×60° 6×60°

Dimensions in mm, subject to change  AWA 61- 0315/ -0355 AWA 61- 0400/ -0630

ZSG 06 Inlet guard a  

2  

   1    3    2   d   1   d    3    d   ø   d   ø   ø   ø

   1    3    2   d   1   d    3    d   ø   d   ø   ø   ø

b4 b5

b4

b3

b5

ø d4 h

b3

øe

Dimension b3 for b3 for pole-types –4D –4E –6D

 AWA 6161-

b4

~b5

ød1

ød2

ød3

~ød31

ød4

øe

h

2

0315 0355 0400 0450 0500 0560 0630

84 100 108 120 135 180 180

25 20 40 30 30 50 50

465 514 565 625 694 790 880

315 355 400 450 500 560 630

330 370 415 465 516 576 646

390 430 495 550 610 690 770

10 10 10 10 10 12 12

432 482 532 592 662 754 844

40 40 50 50 50 60 60

12×30° ~120 12×30° ~120 12×30° ~120 12×30° ~140 12×30° ~150 16×22.5° ~190 16×22.5° ~220

14

~120 ~120 ~120 ~150 ~150 ~220 –

~120 ~130 ~120 ~140 ~135 ~190 ~190

–6E ~120 ~130 ~120 ~150 ~150 ~220 ~220

 Axial Flow Fans

 AQA 61-0315/-0630 61-0315/-0630  AT  ATA 61-0315/-0630 Dimensions in mm, subject to change  AQA 61-03 15/-0 355 AQA 61-04 00/- 0630

ZSG 06 Inlet guard

b2

b2

   3    2   d   1    3    d   ø   d   ø   ø

   3    2   d   1    3    d   ø   d   ø   ø

b4 b5

b4

b3

b5

ø d4

b3

h

� a � l

 AQA 61-

a

b2

b4

~b5

ød2

ød3

~ød31

ød4

h

350 400 460 515 615 675 750

8 8 10 10 15 15 15

78 93 100 112 115 165 170

33 30 50 45 45 65 65

315 355 400 450 500 560 630

330 370 415 465 516 576 646

390 430 495 550 610 690 770

10.5 10.5 10.5 10.5 11 11 11

40 40 50 50 50 60 60



0315 0355 0400 0450 0500 0560 0630

Dimensions in mm, subject to change  ATA  ATA 61 -0315 /-035 5

b5

l

410 460 520 575 655 725 805

–6E

~110 ~110 ~110 ~130 ~140 ~180 ~210

~110 ~120 ~110 ~140 ~140 ~210 ~210

~110 ~110 ~110 ~140 ~140 ~210 –

~110 ~120 ~110 ~130 ~125 ~180 ~180

   s    n    o     i    s    n    e    m     i    D

 ATA  ATA 61 -0400 / - 0630

   5    d

   5    d

  ø

  ø

ø d4 ø d11 øe

b1



Dimension b3 for b3 for pole-types –4D –4E –6D

b5

ø d4 ø d11 øe

b1

 ATA  ATA 61-

b5

ød4

ød5

ød11

øe

Dimension b1 for b1 for pole-types –4D –4E

–6D

–6E

0315 0355 0400 0450 0500 0560 0630

25 20 40 30 30 50 50

7 7 9 9 9 11 11

308 350 394 440 493 552 620

350 400 435 495 560 615 725

375 425 470 530 600 662 760

~120 ~120 ~120 ~140 ~150 ~190 ~220

~120 ~130 ~120 ~140 ~135 ~190 ~190

~120 ~130 ~120 ~150 ~150 ~220 ~220

~120 ~120 ~120 ~150 ~150 ~220 –

15

 Axial Flow Fans

 ARA 61-0315/-0630 61-0315/-0630 Dimensions in mm, subject to change  ARA 61-0315/-0630 a  — 2

a  

   1    2   d    d   ø   ø

b

ø d4 øe

 ARA 61-

b

b5

d1

d2

d4

e



0315 0355 0400 0450 0500 0560 0630

160 160 180 180 200 260 250

– – – – – – –

380 420 470 523 573 639 712

315 355 400 450 500 560 630

9.5 9.5 9.5 9.5 9.5 11.5 11.5

356 395 438 487 541 605 674

8×45° 8×45° 12×30° 12×30° 12×30° 16×22.5° 16×22.5°

 Accessories Protection guard ZSG 04-

Flexible connection ZKE 11-

Protection guard ZSG 04-

z × d4

   3    d   ø

  e   ø

   h

b1

o

m

x

ø d5

y

v

ZKD 01Flanged inlet cone

0315 0355 0400 0450 0500 0560 0630

w

ZBF 01Housing feet

ZKF 11Mating flange

b1

b3

b5

e

h

m

o

v

w

x

y

z×d4

81 61 105 118 136 75 175

464 515 565 640 710 785 837

9.5 9.5 9.5 9.5 9.5 11.5 11.5

356 395 438 487 541 605 674

225 250 280 315 355 400 450

30 30 30 35 35 35 35

130 130 130 130 130 130 130

210 210 240 240 258 295 324

240 280 340 375 415 415 450

176 176 200 200 218 245 274

200 240 300 335 370 370 400

8× 9.5 8× 9.5 6× 9.5 6× 9.5 6× 9.5 8×11.5 8× 9.5

 Anti-vibrations mounts and automatic automatic shutter see accessories. accessories.

16

 Axial Flow Fans

 ARA 62-0315/-0630 62-0315/-0630 Dimensions in mm, subject to change  ARA 62-0315/-0630 a  — 2

a  

   1    d    d    2  ø    d   ø   ø

min bmax

ø d4 øe

 ARA 62-

(min. - max.)* max.)* b

d

d1

d2

d4

e

h



0315 0355 0400 0450 0500 0560 0630

315 - 365 315 - 365 315 - 375 315 - 375 315 - 385 315 - 395 315 - 405

323 363 408 459 511 571 643

380 420 470 523 573 639 712

315 355 400 450 500 560 630

9.5 9.5 9.5 9.5 9.5 11.5 11.5

356 395 438 487 541 605 674

40 40 50 50 50 60 60

8×45° 8×45° 12×30° 12×30° 12×30° 16×22.5° 16×22.5°

 Accessories Protection guard, inlet ZSG 04-

Protection guard, discharge (attachment) ZSG 06-

  e   ø

h

17

 Axial Flow Fans

 AWA  AWA 11-

0200/-0300

Specifications, underlined at choice  AWA 11-0200/-0300 11-0200/-0300

High performance axial flow fan  provent  with  with direct drive Casing incorporating an inlet ring of painted sheet steel, integrated guard fitted conforming to DIN EN 294. Impeller made of galvanised sheet steel shrink-fitted onto the rotor of the integral motor, statically and dynamically balanced. Integral motor protected to IP 54. Sealed deep groove ball bearings, totally maintenance-free. Motor protected protected by built in thermal overload safety switch. Single phase 230 V, 50 Hz, 100% speed controlled.

with wall mounting ring

Volume flow

AWA 11- . 11-  . . . . . . . . . . . . . . . . V = . . . . . . . . . . . . . . . m³/h m³/ h

pressure increase

pfa

= . . . . . . . . . . . . . . . Pa

Media temperature tempera ture

t

= . . . . . . . . . . . . . . . °C

Motor power consumption

Pe

= . . . . . . . . . . . . . . . kW

Speed Spee d

n

= . . . . . . . . . . . . . . . 1/min 1/mi n

Free inlet sound power level

LWA5 = . . . . . . . . . . . . . . . dB

Weight Weig ht

m

Fan-Type

= . . . . . . . . . . . . . . . kg

 Accessories and options (at extra cost) Speed control units (step less, step wise, with, or without casing available) Motor protection unit  Automatic back draught damper damper

18

 Axial Flow Fans

 AWA  AWA 61- / AQA 61-/  AT  ATA 61Specifications, underlined at choice  AWA 61-0315 / -0630 AQA 61-0315 / -0630

0315/-0630 High performance axial flow fan  provent  with  with direct drive. Casing incorporating an inlet ring of galvanised sheet steel and painted, integrated guard fitted conforming to DIN EN 294. Plastic impeller bolted to the rotor of the integral motor, statically and dynamically balanced. Integral motor protected to IP 54. Sealed deep groove ball bearings, totally maintenance-free. Motor protected by built in thermal overload thermo contacts operating in connection with motor protection unit. Ready to connect with a VDE conforming terminal box.  Three phase 230/400 V, V, 50 Hz, or  single   single phase 230 V, 50 Hz, 100% speed controlled.

with with wall wall moun mounti ting ng ring ring

with with squa square re wall wall moun mounti ting ng plate ...............

Fan-Type Volume flow

. V

= . . . . . . . . . . . . . . . m³/h m³/ h

pressure increase

pfa

= . . . . . . . . . . . . . . . Pa

Media temperature tempera ture

t

= . . . . . . . . . . . . . . . °C

Motor power consumption

Pe

= . . . . . . . . . . . . . . . kW

Speed Spee d

n

= . . . . . . . . . . . . . . . 1/min 1/mi n

Free inlet sound power level

LWA5 = . . . . . . . . . . . . . . . dB

Weight Weig ht

m

= . . . . . . . . . . . . . . . kg

 Accessories and options (at extra cost) Guard at discharge  Automatic back draught damper damper Motor protection unit Speed control units (step less, step wise, with, or without casing available) Increased corrosion protection

Specifications, underlined at choice  AT  ATA 61-0315 / -0630

High performance axial flow fan  provent  with  with direct drive. Self supporting integrated guard fitted conforming to DIN EN 294. Plastic impeller bolted to the rotor of the integral motor, statically and dynamically balanced. Integral motor protected to IP 54. Sealed deep groove ball bearings, totally maintenance-free. Motor protected by built in thermal overload thermo contacts operating in connection with motor protection unit. Ready to connect with a VDE conforming terminal box.  Three phase 230/400 V, V, 50 Hz, or  single   single phase 230 V, 50 Hz, 100% speed controlled.

with self supporting inlet guard

Volume flow

ATA ATA 61- . 61-  . . . . . . . . . . . . . . . . V = . . . . . . . . . . . . . . . m³/h m³/ h

pressure increase

pfa

= . . . . . . . . . . . . . . . Pa

Media temperature tempera ture

t

= . . . . . . . . . . . . . . . °C

Motor power consumption

Pe

= . . . . . . . . . . . . . . . kW

Speed Spee d

n

= . . . . . . . . . . . . . . . 1/min 1/mi n

Free inlet sound power level

LWA5 = . . . . . . . . . . . . . . . dB

Weight Weig ht

m

Fan-Type

= . . . . . . . . . . . . . . . kg

 Accessories and options (at extra cost)  Automatic back draught damper damper Speed control units (step less, step wise, with, or without casing available)

19

   s    n    o     i    t    a    c     i     f     i    c    e    p     S

 Axial Flow Fans

 ARA 61-

0315/-0630

Specifications, underlined at choice  ARA 61-0315 / -0630

High performance axial flow fan  provent  with  with direct drive

duct mounted casing

Duct mounted casing with connecting flanges on both sides, made from sheet steel and powder coated or  hot  hot dip galvanised (extra cost) lastic impeller bolted to the rotor of the i ntegral motor, motor, statically and dynamically balanced. Integral motor protected to IP 54. Sealed deep groove ball bearings, totally maintenance-free. Motor protected by built in thermal overload thermo contacts operating in connection with motor protection unit. Ready to connect with a VDE conforming terminal box, fully wired and fitted on casing.  Three phase 230/400 V, V, 50 Hz, or  single  single phase 230 V, 50 Hz, 100% speed controlled.

Volume flow

ARA 61- . 61-  . . . . . . . . . . . . . . . . V = . . . . . . . . . . . . . . . m³/h m³/ h

pressure increase

pfa

= . . . . . . . . . . . . . . . Pa

Media temperature tempera ture

t

= . . . . . . . . . . . . . . . °C

Motor power consumption

Pe

= . . . . . . . . . . . . . . . kW

Speed Spee d

n

= . . . . . . . . . . . . . . . 1/min 1/mi n

Free inlet sound power level

LWA5 = . . . . . . . . . . . . . . . dB

Weight Weig ht

m

Fan-Type

= . . . . . . . . . . . . . . . kg

 Accessories and options (at extra cost) Flexible connectors w/flanges on both sides Mating flange Guard (at intake and discharge) Intake cone w/flange Brackets  Anti vibration mounts  Automatic back draught damper damper Motor protection unit Speed control unit (step less, step wise, with, or without casing available)  Tube  Tube casing protected protected by hot dip galvanisation

20

 Axial Flow Fans

 ARA 62-

0315/-0630

Specifications, underlined at choice  ARA 62-0315 / -0630

High performance axial flow fan  provent  with  with direct drive

duct mounted for flush mounting

Duct mounted for flush mounting in long casing design, made from sheet steel and powder coated or  hot  hot dip galvanised (extra cost) Plastic impeller bolted to the rotor of the integral motor, motor, statically and dynamically balanced. Integral motor protected to IP 54. Sealed deep groove ball bearings, totally maintenance-free. Motor protected by built in thermal overload thermo contacts operating in connection with motor protection unit. Ready to connect with a VDE conforming terminal box, fully wired and fitted on casing.  Three phase 230/400 V, V, 50 Hz, or  single  single phase 230 V, 50 Hz, 100% speed controlled.

Volume flow

ARA 62- . 62-  . . . . . . . . . . . . . . . . V = . . . . . . . . . . . . . . . m³/h m³/ h

pressure increase

pfa

= . . . . . . . . . . . . . . . Pa

Media temperature tempera ture

t

= . . . . . . . . . . . . . . . °C

Motor power consumption

Pe

= . . . . . . . . . . . . . . . kW

Speed Spee d

n

= . . . . . . . . . . . . . . . 1/min 1/mi n

Free inlet sound power level

LWA5 = . . . . . . . . . . . . . . . dB

Weight Weig ht

m

Fan-Type

= . . . . . . . . . . . . . . . kg

 Accessories and options (at extra cost) Guard at intake Guard at discharge  Automatic back draught damper damper Motor protection unit Speed control unit (step less, step wise, with, or without casing available)  Tube  Tube casing protected protected by hot dip galvanisation

21

 Axial Flow Fans

 Accessories Samples Fitted to an outside wall, automatic, weather proof back draught damper at discharge.

 AQA 61ZLK 40

Samples Fitted to a wood or metal wall with clipped guard at discharge.

 AWA 61ZSG 06

22

 Axial Flow Fans

 Accessories Samples Installation with anti-vibration fittings, intake cone, automatic draught damper at discharge.

ZSG 04

ducted tube

 ARA 61-

ZKD 01

ZKE 11

ZLK 40

ZBF 01

ZBD 01

Samples Flush mounted fan unit, with guards, bolted at intake and clipped at discharge.

ZSG 06

ZSG 04

Samples Flush mounted fan unit, with flexible fabrics, bolted at intake and fitted at discharge.

   s    e     i    r    o    s    s    e    c    c    A

23

 Axial Flow Fans

 Accessories Overview 5 ZSG 06 Protection guard, attachment for discharge

6 ZLK 40  Automatic shutter

Overview  ZKE 11 Flexible connection

 ZKF 11 Flange 3 ZSG 04 Protection guard 4 ZKD 01 Flanged inlet cone 6 ZLK 40  Automatic shutter

7 ZBF 11 Housing feet 8 ZBD 01 Rubber buffers

Overview 3 ZSG 04 Protection guard

5 ZSG 06 Protection guard, attachment for discharge

6 ZLK 40  Automatic shutter

24

 Axial Flow Fans

 Accessories Flanges and Connections For line ARA 61  There are flanges and flexible connectors available for intake and discharge

ZKE 11

ZKF 11

Protection Guard For line AQA 61, AWA 61, ATA 61,  The axial flow fans are equipped with intake guard as a standard. Guards for discharge are available as an accessory (ZSG 06)

For line ARA 61, ARA 62 ZSG 04

ZSG 06

 These fans are made for being integrated in a duct system or for wall flush mounting and are not supplied with an intake guard. If there is – by the way of installation or use the fan - no guard provided against a contact with the fan impeller the user has to ensure an appropriate protection according to DIN EN 294. Matching guards are available as an accessory. accessory.

Flanged inlet cone For line ARA 61  The intake cone with flange has to be fitted to the intake of the inline fan if there is no duct connected.  This will improve the intake flow conditions and reduce air flow losses.

ZKD 01

 Automatic shutter  For weather proof cover of the discharge openings.  The automatic back draught damper is made of shock proof, weather and UV- resistant plastic material, colour light grey. It is supply ready for fitting including nuts and bolts.

The back draught damper is made for use under a temperature range of -30 °C to +70 °C. ZLK 40

Dimensions in mm, subject to change   ZLK 40-

a

b

c

d

e

app. kg

0200 0225 0315 0355 0400 0450 0500 0560 0630

210 260 310 360 420 460 510 – –

244 294 347 397 459 501 549 605 696

182 232 276 310 364 395 445 522 626

22 26 26 26 26 26 31 28 31

5 5 5 5 5 5 5 5 5

0.3 0.5 0.7 0.9 1.2 1.7 2.0 2.5 3.0

  a

   b       

e

d

c

25

 Axial Flow Fans

 Accessories Casing feet For line ARA 61  Anti vibration mounts are made for reducing vibrations to the floor base. In combination with the brackets they may be fitted to the inline fan unit.

ZBF 01

 Anti-vibration mounts For line ARA 61  Anti vibration mounts are made for reducing vibrations to the floor base. In combination with the brackets they may be fitted to the inline fan unit.

Dimensions in mm, subject to change Fan  ARA 61-

Quantity

0415/-0450 0500/-0630

4  4 

Rubber buffers ZBD 01-

A

E

F

G

H

K

0405 0606

20 30

25 30

16 20

M6 M8

M6 M8

6.5 9.5

H

   F

   E    K

G

 A 

26

 Axial Flow Fans

 Accessories

ESM

Motor protection unit for motors with fitted thermal control sensors (thermal contacts, PTC)

Design Beautifully shaped plastic casing made of shock resistant polystyrol, protection class IP 54.  All units are suitable for wall mounting mounting and include: hand hand switches for frontal operatioperation, operational signal lamp and control safety accessible from outside. Permissible ambient temperature: +40 °C.

Function Should the motor winding temperature rise excessively, the imbedded motor winding thermal contact or PTC will open the control circuit, causing the mains relay to drop out and thus disconnect the motor from the mains supply.  The motor will also be turned off off in the case of a mains-side mains-side dropout of the control phase, as well as if the contacts fail or if the mains supply is interrupted.  The motor protection units are not equipped equipped with an automatic re-poweron re-poweron after a mains voltage failure and are thus fail-safe.  After the motor windings have cooled down, a lock-out device device in the relay circuit circuit prevents the motor from switching itself on. The hand switch must first be momentarily turned to the 0-position and then back to the ‘on’ position.  The operational signal lamp indicates the operation of the motor. motor. It goes out in the case of a malfunction.  The motor protection units are suitable for group group switching, i. e. several motors motors with the same switching can be connectedto a common switchingdevice.  The sum of the motors’ rated rated power may not exceed exceed the maximal device rated rated power. wer. The thermal contacts of all motors are to be switched in series. The PTCs switched in series may not exceed the sum of 6.

Technical Data for motors with thermal contacts ESM

max. permitted rated motor power kW

Nominal voltage V

Weight kg

01-0020-5E 01-0040-8D 02-0040-8D 03-0040-8D 04-0040-8D

2.0 4.0 4.0 4.0 4.0

230 400 400 400 400

0.9 0.9 0.9 0.9 0.9

for motors with PTC ESM

max. permitted rated motor power kW

Nominal voltage V

Weight kg

11-0040-8D 12-0040-8D 13-0040-8D

4.0 4.0 4.0

400 400 400

0.9 0.9 0.9

For connection type see diagrams

Dimensions in mm, Subject to change

        0         3

        0         4         1

190

150

Please use the enclosed wiring diagrams in the control boxes always!

27

 Axial Flow Fans

 Accessories

ESM

Motor protection unit Connection diagram ESM 01-0020-5E  Alternating current model model,, single speed  ATTENTION:  ATTENTION: for thermo thermo contacts (TK) (TK) use always series connection! N L1

T K T K   TK  TK 

U1 U1 U 1 U 2 U2 U2

TK  U1

Z2

TK

U2

Z1

 Anti-clockwise  Anti-clockwise rotation T K T K   TK  TK  TK

TK

TK  TK  

Connection with 2 motors TK  U1 Z2 T K T K   TK  TK  TK  TK 

Z1 U2

Clockwise rotation

TK  TK 

TK  TK 

PE N L1

Main Mainss

TK

Conn Connec ecti tion on with with 3 mot motor orss

Motor 1-phase

Connection diagram ESM 01-0040-8D Three-phase current model, model , single speed

ESM 02-0040-8D Three-phase current model, model , 2 speed with two separate windings

 ATTENTION:  ATTENTION: for thermo thermo contacts (TK) (TK) use always series series connection!

 ATTENTION:  ATTENTION: for thermo thermo contacts (TK) (TK) use always series series connection!

N L1 L2 L3

N L1 L2 L3

TK TK  TK  TK 

U1 U1 U1 V1 V1 V1 W1 W1 W1

T K TK   TK  TK 

TK TK  TK  TK 

T K T K   TK  TK 

TK TK TK  TK  

TK

Connection with 2 motors

TK 

TK  TK  TK  TK 

Mains

U1

V1

W1

TK W2

U2

V2

TK  TK 

TK  

T K T K   TK  TK  TK 

PE N L1 L2 L3

Connection wi with 3 motors

TK 

Connection with 2 motors

TK TK  TK  TK 

PE N L1 L2 L3

TK

1U 1V 1 W 2U 2V 2W

Motor 3-phase

Mains

TK 

TK 

TK 

TK 

TK 

Connection wi with 3 motors

U1

V1

W1

TK W2

TK 

U2

V2

Motor 3-phase

Connection diagram ESM 03-0040-8D Three-phase current model, model , 2 speed with Dahlander winding

ESM 04-0040-8D Three-phase current model, model , 2 speed with Y/ -connection

 ATTENTION:  ATTENTION: for thermo thermo contacts (TK) (TK) use always series connection!

 ATTENTION:  ATTENTION: for thermo thermo contacts (TK) (TK) use always series series connection!

N L1 L2 L3

N L1 L2 L3

T K T K   TK  TK 

1U 1V 1W 2U 2V 2W

T K TK   TK  TK 

TK

T K   TK  TK 

TK

TK

TK

TK

TK 

TK  

Connection with 2 motors

T K TK   TK  TK 

PE N L1 L2 L3

Mains

28

T K T K   TK  TK 

TK  TK 

TK 

TK 

TK 

TK 

Connection wi with 3 motors

TK 

U1 V1 W 1 U 2 V2 W2

TK  

Connection with 2 motors

TK 

1U

1V

1W

TK 2W

2U

2V

TK TK 

PE N L1 L2 L3

Motor 3-phase

Mains

T K   TK  TK 

TK 

U1

V1

W1

TK 

TK 

TK W2

U2

V2

TK 

TK 

TK 

Connection with 3 motors

Motor 3-phase

 Axial Flow Fans

 Accessories

ESM

Motor protection unit

Connection diagram ESM 11-0040-8D Three-phase current model, model , single speed

ESM 12-0040-8D Three-phase current model, model , 2 speed with two separate windings

 ATTENTION:  ATTENTION: for PTC PTC (KL) use always series connection! connection! N L1 L2 L3

KL KL KL KL

 ATTENTION:  ATTENTION: for PTC PTC (KL) use always series connection! connection!

U1 U1 U1 V1 V1 V1 W1 W1 W1

N L1 L2 L3

K L KL

KL

KL KL KL KL

K L KL

KL

KL

KL KL KL KL

KL

KL

KL

Connection with 2 motors

KL

U1

V1

W1

KL KL KL KL

KL

W 2 U2

V2

KL KL

K L KL KL

PE N L1 L2 L3

Connection wi with 3 motors

KL

1U 1V 1 W 2 U 2V 2W

Connection with 2 motors

KL KL KL KL

PE N L1 L2 L3

Mains

KL

Motor 3-phase

Mains

KL

KL

KL

U1

V1

W1

KL

KL

KL

KL

W 2 U2

V2

KL

KL

Connection wi with 3 motors

Motor 3-phase

Connection diagram ESM 13-0040-8D Three-phase current model, model , 2 speed with Dahlander winding  ATTENTION:  ATTENTION: for PTC PTC (KL) use always series connection! connection! N L1 L2 L3

KL

K L KL

KL

KL

KL

KL

KL

KL

KL

KL

KL

1U 1V 1 W 2U 2V 2W

Connection with 2 motors

PE N L1 L2 L3

Mains

KL

KL

KL

KL

KL

1U

1V

1W

KL

KL

KL

KL

KL

2 W 2U

2V

KL

KL

Connection wi with 3 motors

Motor 3-phase

29

 Axial Flow Fans

 Accessories

ETO

Transformer  with 7 secondary taps

Design  Transformer  Transformer according to DIN VDE 0550-1 with built-on built-on terminal strip for 7 taps, without casing, suitable for control cabinet installation.  Two  Two transformers are necessary necessary for three-phase three-phase current, which are are to beconnected beconnected in a V-switching configuration (see Wiring diagram). Permissible ambient temperature at nominal current loading max. +35 °C.

ETO 10-....-5E Primary voltage: 230 V / 50-60 Hz Secondary voltage: 230/180/160/140/120/100/80 V

ETO 10-....-8D Primary voltage: 400 V / 50-60 Hz Secondary voltage: 400/310/270/235/200/170/140 V

Technical Data | Dimensions  Alternating current model model Nominal current ETO A 10-0018-5E 10-0040-5E 10-0070-5E 10-0130-5E  10-0130-5E   10-0220-5E

1.8 4.0 7.0 13.0 13. 0 22.0

Dimensions in mm, Subject to change a b c e øf

h

kg

78 96 120 135 135

44 61 73 86 126

1.5 2.5 4.5 7.0 12.5

Dimensions in mm, Subject to change a b c e øf

h

kg

78 96 120 135 135

44 61 73 86 126

1.5 2.5 4.5 7.0 12.5

60 80 95 110 150

92 107 126 135 135

56 84 90 104 104

4.8 5.8 5.8 5.8 5.8

Technical Data | Dimensions Three-phase current model Nominal current ETO A 10-0010-8D 10-0020-8D 10-0040-8D 10-0065-8D 10-0150-8D

1.0 2.0 4.0 6.5 15.0

60 80 95 110 150

92 107 126 135 135

56 84 90 104 104

4.8 5.8 5.8 5.8 5.8

Measurement diagram

  c

øf  h b

e a

Connection diagram ETO 10-....-5E Mains L

ETO 10-....-8D Motor

N

U1

Mains U2

   V    V    V    V    V    V    V    V    0    0    0    0    0    0    0    0    3    8    6    4    2    0    8    2    1    1    1    1    1

30

L1

Motor L2 L3

   V   V   V   V   V   V   V   V    0   0   0   5   0   0   0   0    0   1   7   3   0   7   4    4   3   2   2   2   1   1

U1

V1

W1

   V   V   V   V   V   V   V   V    0   0   0   0   5   0   0   0    4   7   0   3   7   1   0    1   1   2   2   2   3   4

 Axial Flow Fans

 Accessories

ETH

Speed setting transformatic, 5-step, with casing

Design Completely plastic casing in protection class IP 54, Type: ETH 31, 35 and ETH 37-0010/-0020-8D. 37-0010/-0020-8D. Painted metal casing in protection class IP 23, Type: ETH 36 and ETH 37-0040/-0070-8D.  All units are suitable for wall mounting mounting and include: speed speed control via hand switch with 0-position and 5 switching steps, operating signal lamp, 230 V output for e. g. a solenoid valve. Permissible ambient temperature: -25 °C up to +40 °C.

ETH 31  These units include no motor motor protection unit. Protection Protection switches for thermal thermal contact connections are to be laid in the conductor between the control device and the motor. In Nicotra Gebhardt externallymounted rotor motors, the thermal contacts are already bound into the motor winding.

ETH 35, ETH 36, ETH 37  These units possess a motor protection protection installation for thermal thermal contact or PTC connection with a supplementary warning signal lamp, a potential-free exchanger exchanger and a room thermostat connection (remote on – off).

Function For motors with built-in thermal contacts, these open the control current circuit when the permissible winding temperature is exceeded (ETH 31, 35, 36). Motors equipped with PTC thermistor give an electrical signal to the trigger unit (ETH 37) when the temperature exceeds the default value. The trigger controls the main relay thus cutting the motor feed. This causes the main fuse to fall out and disconnect the motor from the mains.  After the motor winding has cooled cooled down (ca. 2 Min.) or after remedying the the cause of the malfunction, respectively, respectively, turn the main switch temporarily to the 0-position and then back to the operational position.

31

 Axial Flow Fans

 Accessories

ETH

Speed setting transformatic, 5-step, with casing

Technical Data Primary voltage: 230 V; 50-60 Hz Secondary voltage: 60/105/130/160/230 V

 Alternating current model model without motor protection installation Nominal current Mains safety ETH A 31-0020-5E 31-0040-5E

2.0 4.0

with motor protection installation Nominal current Mains safety ETH A

2 AT 6 AT

4.0 6 AT 7.0 8 AT 20.0 20 AT

35-0040-5E 35-0070-5E 36-0200-5E

Technical Data Primary voltage: 400 V; 50-60 Hz Secondary voltage: 90/140/180/230/400 V

Three-phase current model with motor protection installation Nominal current Mains safety ETH A 1.0 1 AT 2.0 2 AT 4.0 4 AT 7.0 8 AT 14.0 16 AT

35-0010-8D 35-0020-8D 36-0040-8D 36-0070-8D 36-0140-8D

with motor protection installation for motors with PTC Nominal current Mains safety ETH A 1.0 2.0 4.0 7.0

37-0010-8D 37-0020-8D 37-0040-8D 37-0070-8D

1 AT 2 AT 4 AT 8 AT

Dimensions in mm, Subject to change ETH

a

b

c

d

e

f

g

kg

31-0020-5E 31-0040-5E 35-0040-5E 35-0070-5E  35-0070-5E   36-0200-5E  36-0200-5E   35-0010-8D 35-0020-8D 36-0040-8D   36-0070-8D  36-0070-8D   36-0140-8D  36-0140-8D   37-0010-8D 37-0020-8D 37-0040-8D  37-0040-8D   37-0070-8D  37-0070-8D  

155 155 155 200 225 155 200 225 225 302 200 200 225 225

200 200 200 254 305 200 254 305 305 385 254 254 305 305

150 150 150 170 165 150 170 165 165 223 170 170 165 165

144 144 144 194 265 144 194 265 265 350 194 194 265 265

98 98 98 140 188 98 140 188 188 265 140 140 188 188

6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2

30 30 30 30 30 30 30 30 30 30 30 30 30 30

4.0 4.0 4.0 8.0 17.0 6.0 8.0 14.0 20.0 35.0 5.5 8.0 14.0 20.0

Measurement diagram

1

2 3 4



5

0

d

        b

a

32

c

g

e

 Axial Flow Fans

 Accessories

ETH

Speed setting transformatic, 5-step, with casing

Connection diagram

N

L1

PE N

L1

Mains

PE U1 U2 PE L1

N

PE U1 U2 PE L1

N

Motor



Connection diagram

N

L1

PE U1 U2  TK TK RT RT  PE L1 N

11 12 14

PE N

L1

PE U1 U2

PE L1 N

11 12 14





Mains

Motor

Connection diagram

N

L1 L 2 L3 L3

PE U1 V1 W1 TK TK RT RT  PE L1 N

11 12 14

PE N

L1 L2 L3

PE U1 V1 W1

PE L1 N

11 12 14





Mains

Motor

Connection diagram

N

L1 L 2 L3 L3

PE U1 V1 W1PTC PTC RT RT  PE L1 N

11 12 14

PE N

L1 L2 L3

PE U1 V1 W1

PE L1 N

11 12 14





Mains

Motor

TK = Thermal contact contact of the motor PTC = Positive Temperature Temperature Coefficient (PTC-Thermistor) of the motor RT = Room thermostat or external switch  = additional outlet e. g. for solenoid valve, lamp, etc. “Operating/Malfunction”  = free contacts for the status signal “Operating/Malfunction”

33

 Axial Flow Fans

 Accessories

EPH

Transformer electronic, stepless

Design Shock-resistant plastic casing (creamwhite) in protection class IP 44, with turn knob on the front side. Clearly arranged terminal strip for mains and motor connection. For use as an integral v ersion in a standard switch box, the speedregulator with its front plate is simply removed from the casing underside.

Function  The transformer contains contains a turn knob for the variation of the the nominal value by means means of phase-angle control, semiconductor fuse and a response output.  The transformer EPH is not equipped equipped with any motor protection protection installation! If thermo contacts are in use it i s recommended to assure the electrical safety by installing motor protection units ESM 01-0020-5E.

Technical Data Nominal current A

Nominal voltage V

Frequency Hz

Fuse

EPH 03-0010-5E 03-0020-5E 03-0040-5E

1.0 2.0 4.0

230/240 230/240 230/240

50/60 50/60 50/60

F 1.0 A F 2.0 A F 4.0 A

Dimensions in mm, Subject to change EPH 03-0010/-0040-5E Surface mounting version

EPH 03-0010/-0020-5E flush mounting version Sealing

ø4

        4         6

82

~65

24

Connection diagram

N N Re L

34

M N

32

 Axial Flow Fans

 Accessories

EPA  EPA 

Transformer electronic, stepless Electronic transformer with stepless adjustable output voltage for fans with controllable alternating current motors.

Design EPA 03-….-5E Completely plastic casing in protection class IP 54.

Function  The Transformer Transformer EPA EPA 03 is equipped with a motor protection protection installation for thermal thermal contact connection, nominal value input, main switch, operating signal lamp, semiconductor fuses and adjustment options for minimal and maximal speed.

Technical Data EPA

Protection class max. current cons. IP A

Nominal voltage Frequency V Hz

app. Weight kg

03-0060-5E 03-0100-5E

54 54

230 230

1.3 1.9

0.2/- 6.0 0.2/-10.0

50/60 50/60

Dimensions in mm, Subject to change

241 213

122         0         3

       7       5         3        8         1        1         0         1

        0         6

198 5

Connection diagram

Max. contact capacity 5 A / 250 V AC Direct controller Input (Ri > 100k W ) PE PE PE L1 L1 N

PE

L1

Mains 1~ 230V 50/60Hz

N U1 U1

U2 U2

 TK 

U1

Z2

 TK 

Z1

U2

C in motor

12 11 14

 TK 

24V

10V

E

 A 

 TK 

GND

GND

GND

GND

1-phase motor with integrated thermo contacts

 TK 

U1

Z2

 TK 

Z1

U2

C in motor

1-phase motor with integrated thermo contacts

 A  B

1k �

+

+

N

J3

Input 0-10V

Output 0...10V (Imax=10mA)

35

 Axial Flow Fans

 Accessories

EPA  EPA 

Transformer electronic, stepless for voltage controlled single phase motor with capacitor winding

Design Speed regulator specially designed for control single phase fan drives. Noise reduced operation by high control frequency (19 kHz). Integrated power factor correction for sinus shaped feed current. Integrated radio noise filter to match EMC regulations.

Function Speed control: DC 0-10 V (through external potentiometer or external DC), can be switch to internal potentiometer (n min ). Minimum and maximum speed can be set (n min, nmax ). Pressure/temperature Pressure/temperature control: Digital input with ramp function to achieve a cheap control with pressure/temperature switches. Motor protection by current monitoring and connection of thermo contacts possible. Short circuit protected, automatic restarting device. Error messages: High temperature of controller, controller, thermo contact, short circuit, one relais output with switch over contact and reset button. Parametration possible via serial intersection for user specific use.

Connection and fitting Main 230 V, V, 50/60 Hz, fitted in vertical position. Output voltage: 10…98 % of input voltage. Radio noise suppression to EMC-Standard EN 50081-1, EN 50082-1. For cable length up to 10 m (shielded).

Recommendation We recommended the Nicotra Gebhardt pressure switch EIP 40, because the overall control precision depends on precision of the pressure switch.

Technical Data Protection class

Nominal current

input

max. power consumption

app. Weight

Operating temperature

EPA

IP

A

V

W

kg

°C

93-0023-5E

54

2.3

0-10

18

1.2

0 ... +40

Dimensions in mm, Subject to change 140

        5         0         8         5         1         1

55

155

Connection diagram

1

L

N

2

3

Lm N1 R/L 4

5

6

7

8

9

10

   A    0    1

36

PE

L

N

PE

U1 U1

  p   o    t    S

   V    0   a    1    P   +

   V    0    1  .  .  .    0   +

21 22 23 24 25 26

 Axial Flow Fans

 Accessories

EPA  EPA 

Transformer electronic, stepless, digital Electronic controller for pressure, airspeed, temperature, with stepless adjustable output voltage for fans with controllable alternating current or threephase current motors respectively.

Design EPA 83 - Surface mounting version Plastic casing with die-cast aluminium base-plate in protection class IP 54.

Function  The pressure controller controller EPA EPA 83 is equipped with a main switch, switch, a motor protection by thermal contact or PTC thermistors, nominal value input, main switch/automatic with bypass-function, actual value input for sensors with 0-10 V signal (Temperature (Temperature sensor EIT, Differential Differential pressure sensor EIP and Air velocity sensor EIL), for sensors with 4-20 mA signal; semiconductor fuses and adjustment options for minimal and maximal speed, menu-directed set-up via three function keys, output (0-10 V), potential-free operation signal contact, external nominal value preset via potentiometer, potentiometer, integrated semiconductor fuses, phase monitoring, controller block, reset pushbutton connection.

Technical Data  Alternating current design design Protection class max. current cons. EPA IP A 83-0060-5E 83-0100-5E

54 54

0.2/- 6.0 0.2/-10.0

Nominal voltage Frequency app. Weight V Hz kg 230 230

50/60 50/60

1.6 2.6

Technical Data Three-phase current design Protection class max. current cons. EPA IP A 83-0050-8D 83-0100-8D 83-0150-8D 83-0250-8D

54 54 54 54

0.2/- 5.0 0.5/-10.0 0.5/-15.0 0.5/-25.0

Nominal voltage Frequency app. Weight V Hz kg 400 400 400 400

50/60 50/60 50/60 50/60

2.7 3.1 5.2 13.6

37

 Axial Flow Fans

 Accessories

EPA  EPA 

Transformer electronic, stepless, digital

Dimensions in mm, Subject to change EPA 83-0060-5E Surface mounting version

EPA 83-0100-5E Surface mounting version

140.5 115

128 213

240

102         0         3

       7       5         3        8         1        1

        4         5         6         2         2         2

        0         1

        0         6

        5   .         5       ø

198 5

186

13

Dimensions in mm, Subject to change EPA 83-0050-8D Surface mounting version

EPA 83-0100-8D Surface mounting version

131 115

240

        4         5         6         2         2         2

131 115

240

        4         5         6         2         2         2

        5   .         5       ø

186

        5   .         5       ø

13

186

13

Dimensions in mm, Subject to change EPA 83-0150-8D Surface mounting version

EPA 83-0250-8D Surface mounting version

131 115

240

       7         1       7         3

304 282 267

261 244

        2         1

        4         5         6         2         2         2

        4        5         0         9         3         2         3         4         3         5   .         5       ø

186

38

13

ø9

 Axial Flow Fans

 Accessories

EPA  EPA 

Transformer electronic, stepless, digital

Connection diagram EPA 83-....-5E

 Auto 0 100%

 V 

   1    N    I    l    a    t    i    g    i    D

D-

Max. contact capacity 5 A / 250 V AC

D+

PE P E N

N L1 L 1 U1 U1 U 1 U 2 U 2 11 1 2 14 14

21 22 24

K1

24V

N L1

E 1. 1.1 E 1. 1. 2

   1    T    U     O    g    o    l    a    n    A

   2

   2

   1

   N    I    l    a    t    i    g    i    D

   N    I    g    o    l    a    n    A

   N    I    g    o    l    a    n    A

 TK 

D1

 A1

D2

E2

E1

 TK 

D1

GND

D2

GND

GND

DATA - GND RS485

1~ 230V 50/60Hz

E 2. 2.1 E 2. 2. 2 GND

1

Input

U1 U2 PE PE TK TK  1* If function is not needed, terminals must be bridged M 1~

Mains

mA

1*

K2

+

PE

°C

0...10 V (Ri>100 k) 0...20 mA 4...20 mA KTY10-6 (-8...+43°C)

2

Output 0...10 V (Imax=10 mA) 1-phase motor with integrated thermo contacts

Input 0...10 V (Ri>100 k) 0...20 mA 4...20 mA KTY10-6 (-24...+80°C)

Connection diagram EPA 83-....-8D

   1    T    U     O    g    o    l    a    n    A

   1    T    U     O     C    D    V    4    2

D1

 A 

24V

D1

GND

24V

   1    N    I    l    a    t    i    g    i    D

Max. contact capacity 5 A / 250 V AC GND N L 1 L2 L3 U

V W

11 14 12 21 24 22 K1

PE N L1 L2 L2 L3

Mains 1~ 230V 50/60Hz

U

V M 3~

W PE PE

 TK   TK 

   1

   2

   2

   N    I    g    o    l    a    n    A

   N    I    g    o    l    a    n    A

   N    I    l    a    t    i    g    i    D

E1

E2

D2

GND

GND

°C

E2.1 E2.2

D2 E1.1 E1.2

 V 

DD+

mA

GND 24V

K2

1

Output

Input

0...10 V (Imax=10 mA)

0...10 V (Ri>100 k) 0...20 mA 4...20 mA KTY10-6 (-24...+80°C) 2

 TK   TK 

3-phase motor with integrated thermo contacts

Input 0...10 V (Ri>100 k) 0...20 mA 4...20 mA KTY10-6 (-8...+43°C)

39

 Axial Flow Fans

 Accessories

ERA 

Universal control device for installation in control cabinets Digital control module for controlling pressure, air velocity or volume flow (PI controller). For example, a transformer for fans is controlled via the 0-10 V output. The device is designed for installation in control cabinets.

Type Multi functional LC-display for actual and nominal values (m/s, hPa = mbar, mbar, 100 m³/h). Menuassisted adjustment via three function keys.  Actual value input 0-10 V e. e. g. for: - air speed sensors Type EIL... in measuring ranges from 0-1 m/s and 0-10 m/s e. g. for:  Air velocity control in clean room technology - Pressure sensors Type EIP... in measurement ranges 50-4000 Pa e. g. for: Pressure control in canal systems of air conditioning systems (VVS), Flow control in centrifugal fans with pressure tappings in the inlet cone.The control module calculates the required flow (m³/h) from the differential measured pressure between the surrounding level and inlet cone. - Output 0-10 V e. g. for controlling a transformer. - Failure message is output via display (internal/external) and relay programmable. - External set value s pecification via potentiometer or 0-10 V signal. - Specification of two set values (day/night), can be switched over externally or via keyboard. - Protection against unauthorised setting by keyboard code.

 Application area - Pressure regulation for centralised ventilation systems and variable volume flow systems for building air conditioning (VVS) e.g. in combination with a frequency inverter or a commutation unit or a transformer and a pressure sensor. - Volume flow regulation for centrifugal fans (with measuring stub in the inlet cone) e.g. in combination with a frequency inverter or a commutation unit or a transformer or a mini-interface inverter and a pressure sensor and the volume flow volumeter. - Air speed regulation for clean room systems, e.g. in combination with a transformer and an air speed sensor.

Electrical connection and installation Connection to 230 V, V, 50/60 Hz. The control module can be installed in a control cabinet door. door. Admissible relative humidity: 85 %, noncondensing. Power supply for the sensors included: +24 V, ±20 %, I max = 70 mA.

Setting options

_

_

·  V = K p = K 10 r2

p

– Set values in the measurement range of the sensor (m/s, hPa = mbar), or in the volume flow range of the fan (x 100 m³/h) – Switch over of set value (day/night) – Min./max. setting range – Translation of performance curve (P component) – Constant of integration can be selected (I component) – Reversal of the effect of the control behaviour – Rotation of the performance curve – Switchover or programming of internal/external set value – Sensor selection via keypad – Programming for ”Filter fault” – Keypad code – K factor entry (The K10-factor can be found in the current lists of our fan line)

Technical Data

40

Input

Out max.

ERA

V

mA

02-4000-5E

0...10

10

Protection class IP 20

Operating consumption

Operating temperature

VA

°C

< 10

0 ... +55

 Axial Flow Fans

 Accessories

ERA 

Universal control device Dimensions in mm, Subject to change

        6         0         1

166.5

44 max.

10.5

105

        9         9

159

Instrument panel window

Connection diagram

°C  V  mA  E2

1

2

3

4

5 °C  V 

(+) (+) (–) (–)

D+

24V

24V

D2

 A1

GND

E1

L1 N PE

D–

GND

D1

D3

 A2

GND

E2

mA  E1

11 14 12 21 24 22 K1

Line

+ DATA  A B GND GND RS485

 A2

E2



4

K2

+

(Imax=10mA)

+

 A1

E1



3

+

(Imax=10mA)

1 Out, 24 V DC 2 Input, Digital 1/2/3 3 Out, Analog 1/2 4 Input, Analog 0-10 V 1/2 5 Contact rating max. 5 A / 250 V AC

 Out 0-10 V  Out 0-10 V 3 Input 0-10 V 4 Input 0-10 V

41

 Axial Flow Fans

 Accessories

EIP

Differential pressure sensor Sensor with membrane for measuring the pressure, negative pressure or differential pressure of nonaggressive gases.

Type  The differential differential pressure to be measured measured acts transformed transformed into an output signal of 0...10V by electronics (in SMD technology).

 Application ranges  Volume flow regulators regulators in centrifugal fans fans (with volume flow measuring measuring device IMV) in connection with a frequency inverter type G110, MM420, MM430, or a universal regulator appliance type ERA 02-4000-5E in connection with a frequency regulator Electrical connection and installation

 The differential differential pressure sensor delivers a starting signal (0-10 V) by pressure pressure increase at the ”Plus” connection opposite pressure on the ”Minus” connection. Voltage supply: 15-30 V DC or 24 V AC, ±15 %. Pressure connections must point downward, tube connection ø5 mm.

Measuring accuracy Null drift: ±0.75 % Sum of linearity and hysteresis: ±1 %  Temperature  Temperature drift zero zero point: ±0.3 % / 10 K  Temperature  Temperature drift length length of measurement: measurement: ±0.2 % / 10 K 

Technical Data Protection Protection type

EIP

Measuring range Pa

max. current consumption ca. mA

Overload protection Pa

Output signal prop. V DC

Operating temperature °C

20 21 22 23 24

0 - 200 0 - 500 0 - 1000 0 - 2000 0 - 4000

IP65 IP65 IP65 IP65 IP65

12 12 12 12 12

20000 20000 20000 20000 20000

0-10 0-10 0-10 0-10 0-10

0 bis +50 0 bis +50 0 bis +50 0 bis +50 0 bis +50

Dimensions in mm, Subject to change 50

70    5  ,    4

   0    0    5  .   a   c

ø5 8 16

Connection diagram Pressure connections Voltage supply Ø5 mm 15...30 V DC 24 V AC ±10 %    

brown +

+~

�p

yellow

Output 0 ... 10V DC

�p

 

42

-

=

white ^

~

 Axial Flow Fans

 Accessories Time control module  The time control module module ETG is for the implementation implementation of time-controlled time-controlled discharged air systems. With the time switch module ETG all fans with i ntegrated single phase AC motors (1~; 230 V; 50 Hz, 0...7 A) can be controlled.  Allocation is via the motor nominal nominal current.  The operating intervals can be freely programmed, programmed, and if required, required, the second pre-set pre-set speed stage can be changed. Programming the selected weekly cycle is possible by using up to 42 programmable switching points.  The system is equipped with automatic automatic changeover between between summer and winter winter times, as well as integrated motor protection for motors with thermal contacts.

Technical Data Time switch module ETG for fans with single-phasen-AC motors 230 V; 50 Hz Controlling Nominal current ETG A  01-0018-5E 01-0040-5E 01-0070-5E

time time time

1.8 4.0 7.0

Dimensions in mm, Subject to change

        0         0         3

300

170

43

 Axial Flow Fans

Description General  The axial flow fan line is suitable for conveying air or other gases or vapours which are not particularly aggressive.  The minimum temperature for the conveying media is -30°C and the upper temperature limit is given with the data of the technical specification of each type. Flow direction “suction over motor flange”. Horizontal or vertical installation is possible.

Protection  AQA 61, AWA 61  The axial flow fans are equipped with intake guard as a standard.

Guards for discharge are available as an accessory  ARA 61, ARA 62,  These fans are made for being integrated in a duct system or for wall flush mounting and are not supplied with an intake guard. If there is – by the way of installation or use the fan - no guard provided against a contact with the fan impeller the user has to ensure an appropriate protection according to DIN EN 294.

Matching guards and automatic back draught dampers (discharge side) are available as an accessory.

 Accessories Every accessory has to be ordered separately. separately. Specification, technical data and dimensions see chapter “accessories”. The selection of the matching control units is specified wi th the table “Technical “Technical data”

Motoren  The integrated motors are of protection class IP 44 or IP 54, - isolation class B, equipped with maintenance free deep grove ball bearings. They are selected for permanent operation S1 to VDE 0530. In order to protect them against thermal overload they are provided with thermo contacts.  The thermo contact either protect the motor by direct switch off because of being fitted in series with the motor winding, or in connection with a motor protection unit. So overload of the motor will be safely prevented. Please check wiring diagrams.  All motors are 100% speed controlled.  The speed variation is caused by a voltage variation and a subsequent change of the rotational slip.

Elektrical wiring  AWA 11  The fans of the line AWA 11- are supplied, as a standard, without terminal box. They are equipped with a free cable lead of about 450mm. The capacitor is supplied loose.

 AQA 61, AWA 61, AT ATA 61, ARA 62  The fans of this line are supplied, as a standard, with a loose cable wired to a terminal box. For single phase units the capacitor is included.

 ARA 61  This fan line has a terminal box fully wired and fitted on fan casing. For single phase units the capacitor is included. Each fan or service switch is provided with a wiring diagram  The relevant wiring diagram may be found at:

www.nicotra-gebhardt.com

44

 Axial Flow Fans

Description Performance data  The performance data have been taken with a test rig according to DIN 24 163. .  They show the pressure increase pfa of the fan as a function of the flow rate V  for the arrangement free intake – free discharge.  The data are valid for a density of the conveying media of r1 = 1.15 kg/m³.

Sounds  The fan curves include the a-weighted sound power data for free intake LWA5 according to DIN EN 25 136. They differ from the total sound power by having been Aweighted.  The data have been taken according to DIN EN 25136 suction side by applying the envelope method.  The weighted sound pressure data Lpa for a distance of 1m from intake can be approximately calculated by subtracting 7 dB from the A-sound-power value.  Attention must be given to the ambient acoustical conditions, duct connections, resonances, reflections, etc. which may have an influence on the sound properties of the system.  The sound power levels in the octave bands are taken as follows:  The relative sound power levels for the duty point – free intake – can be taken from the table below.

Determination of the Octave level

Fan type 10Fan type 60-

fm

63

125

250

500

1000

2000

4000

8000

Hz

LWrel LWrel

15 15

14 4

4 4

4 4

8 6

5 6

10 11

15 21

dB dB

45

   s    e    t    o    N     /    s    n    o     i    t    p     i    r    c    s    e    D

 Axial Flow Fans

Notes Quality management system DIN EN ISO 9001 Nicotra Gebhardt quality is the result of rigorously pursuing business policy goals, which specify that Nicotra Gebhardt products must display properties and characteristics that are clearly above average when compared to similar products.  This maxim, which has applied since since the company was founded, founded, lead in April 1985 to the auditing and certification of the existing quality assurance system. In subsequent years, it was adjusted to comply with changed international and European standards. Modern production procedures, monitored by our quality management system, ensure a high level of repeatability in manufacturing.  The tight tolerances allow high high levels of data security for our our products.

Information on machine safety  The fans listed in this catalogue catalogue are classified as not automatically operable mamachines in terms of the EC machine guideline 98/37/EC, and shall therefore be given a manufacturer’s declaration.  A CE mark with regard to the low-voltage guideline will be given.  The assessment of danger danger arising from the fan and requisite safety measures measures occuroccurred resulting from the VDMA (Association of German Mechanical Engineering Institutions) standard sheet 24 167: Fans; safety requirements.  The Operating Instructions give give which safety measures measures are still necessary on assemassembly to ensure that the fans comply with the EU Machine Guideline 98/37/EG.

Notes on catalogue data We reserve the right to change the dimensions and technical data contained in this catalogue in the event that our product is further developed. All details correspond to the version on the date of printing.

General Delivery and Payment Conditions  (DPC) Our General Delivery and Payment Conditions (DPC) are online at www.nicotrawww.nicotragebhardt.com.

46

 Axial Flow Fans

Notes Service Our mobile service offer for intervention on the site in combination with our standby team at the workshop will assure an efficient support to all requirements you may have. Make just a phone call and our service team will help you to solve your problem fast and reliably.

Service Hotline

Phone Fax

+49 (0)7942 / 101-384 +49 (0)7942 / 101-385

The part shop offered by Nicotra Gebhardt  The easy-to-handle online shop enables you to identify instantly every spare part. part. A graphically supported list makes your selection easy. So an online service is available which will help you to make your repair as simple as possible.

www.nicotra-gebhardt.com

47

  e   g    i   e    t    S    /   n   e   g   n    i    l   s    i   e    G  ,   g   a    l   r   e    V    d   n   u    k   c   u   r    D    R    E    R    U    A    M  .    C   y    b   y   n   a   m   r   e    G   n    i    d   e    t   n    i   r    P   –    9    0    0    2  .    7    0      0    0    0    0   –    6  .    3    F    F    A      N    E

Nicotra Gebhardt GmbH

48

Nicotra Gebhardt S.p.A

Gebhardtstrasse 19-25 74638 Waldenburg Germany

 Via Modena, 18 24040 Zingonia (Bergamo) Italy

 Telephone  Telephone +49 (0)7942 101 0  Telefax  Telefax +49 (0)7942 101 170 E-Mail [email protected]

 Telephone  Telephone +39 (0)35 873 111  Telefax  Telefax +39 (0)35 884 319 E-Mail [email protected]

www.nicotra-gebhardt.com

www.nicotra-gebhardt.com

View more...

Comments

Copyright ©2017 KUPDF Inc.
SUPPORT KUPDF