Nemo Analyze 6 Manual

January 2, 2017 | Author: ciszqo | Category: N/A
Share Embed Donate


Short Description

Download Nemo Analyze 6 Manual...

Description

User Manual

Version 6.60

2

© 2013 by Anite Finland Ltd. All rights reserved. This manual, as well as the software described in it, is furnished under license and may only be used or copied in accordance with the terms of such license. The information in this manual is intended for informational use only and is subject to change without notice. Anite Finland Ltd assumes no responsibility or liability for any errors or inaccuracies that may appear in this user manual. Except as permitted by such license, no part of this publication may be reproduced or transmitted in any form or by any means, electronic, mechanical, recording, or otherwise, without the prior written permission of Anite Finland Ltd. Windows® XP Pro, Windows Vista, Windows® 7, and Windows® Network Monitor are registered trademarks of the Microsoft® Corporation. MapInfo® is a registered trademark of the MapInfo® Corporation. Sentinel is a registered* trademark of SafeNet, Inc. Any other trademarks or service marks contained herein are the property of their respective owners. Revision 6.60.02 Last Edited October 2013

CO N TEN TS

3

CONTENTS QUICK GUIDE

9

SETTING UP THE SYSTEM

9

BEFORE YOU BEGIN

10

END-USER LICENSE AGREEMENT

10

NOTES

10

INSTALLING NEMO ANALYZE

11

HARDWARE AND SOFTWARE REQUIREMENTS

11

NEMO ANALYZE INSTALLATION

11

LICENSING License Server (Floating License) HASP USB key Technical Support Expiration

15 15 20 24

STARTING NEMO ANALYZE

25

USING NEMO ANALYZE

26

WORKSPACE

27

EXPORTING/IMPORTING FAVORITE PARAMETERS

29

WORKSPACE FILTERS

31

CREATING THE DATABASE

33

ADDING FILES TO THE DATABASE Migrating Nemo Analyze database to a new laptop Importing Image Files as Maps

33 34 35

ORGANIZE MEASUREMENTS Drag & Drop Folders Search Folders Hiding Folder Content Query Folders Refresh All Folders

37 40 41 47 48 52

JOINED MEASUREMENTS

53

ADDING DESCRIPTIONS TO MEASUREMENT FILES AND FOLDERS DELETE FOLDER CONTENTS

57

RETRIEVING ORIGINAL FILES FROM THE DATABASE

57

DATABASE CLEANUP

59

VIEWING MEASUREMENT DATA

60

PARAMETERS Statistics/Statistics with filters over Parameter Statistics by/Statistics with Filters by: No Grouping Parameter Launchpad Change Defaults

60 63 63 69 71

VIEWING MEASUREMENT DATA IN GRAPHS

74

55

4

VIEWING MEASUREMENT DATA ON MAP 76 Changing default map 76 Opening Measurement Files on Map 77 Opening BTS Files on Map 81 Viewing Notification Icons on Map 84 Use Case 1.: Viewing Cell Footprints, RSCP Footprints, and LTE Footprints Use Case 2.: Viewing Uplink Voice Quality Server Data 88 Use Case 3.: Viewing IP/UDP Packet Trace Data 92 PARAMETER FILTERING 100 Filtering Based on Polygon Area 103 Use Case 4.: Global Parameter Filtering Based on a Secondary Parameter FILTERING DATA AND CREATING CUSTOM KPIS

123

125

GRAPHS 125 Graph Tools Menu 125 Graph Popup Menu 127 Change Graph Type 127 Reset 127 Query 127 Pick Parameter 128 Add Function 129 Add Reference Line 129 Tool 130 Mode 130 Side Panel 132 Line Graph Filled 135 3D Mode 135 Group Values 136 Graph Properties 137 Layer Properties 139 Use Case 5.: Multiple Graph Layers 143 Use Case 6.: Notification Icons in Graphs 146 Use Case 7.: Correlating Parameters Using Color Grids and Surface Graphs GRIDS 151 Side Panel 151 Row Details 154 Export Data to 154 Grid Properties 155 Use Case 8.: Color Sets in Grids 157 Use Case 9.: Play Audio Sample 160 Use Case 10.: Using L3 and RRC Message Search Parameters 162 MAPS Viewing on Live Map Google Street View

106

113

DRILL-DOWN 118 Drilling Down from Map Data View 121 Drilling Down from Troubleshooting Parameters in Map Data View

DATA VIEWS

86

164 164 167

148

CO N TEN TS

5

Google Earth 169 Map Tools Menu 169 Map Popup Menu 171 Add 171 Find 173 Generate Color Set 174 Export to KML File 174 Side Panel - Map 176 Tool 179 MapX 179 Map Properties 181 Route Properties 182 Draw Route as Symbols 185 BTS Files 187 Use Case 11.: Adding Map Layers and Saving Layer Combinations as Geosets 196 Use Case 12.: Coloring Routes Based on BTS Coverage198 Use Case 13.: Performing Area Binning 199 Use Case 14.: Comparing Two Groups of Measurements from the Same Route on Map Use Case 15.: Displaying Base Station Cell Beam Range on Map214 Use Case 16.: Synchronizing Base Station Map Overlay with Grid Rows 220 Use Case 17.: Using BTS Reference Parameters 223 Use Case 18.: Displaying Base Station Connections on Map Based on Any Parameter SPREADSHEETS 231 Editing Cell Format 235 Filtering Data 239 Creating Formulas 240 Adding Functions 241 Use Case 19..: Retrieving Data from Minimized Data Sets243 Use Case 20.: Creating Reports and Report Templates Using Spreadsheets PROCESSING UPLINK VOICE QUALITY DATA

251

INDOOR MEASUREMENTS

252

NUMERICAL DATA VIEWS

255

INFO VIEWS

258

TIMELINE VIEW Highlight Parameter in Timeline View Notifications in Timeline View Range Selection in Timeline View

259 260 261 263

OTHER VIEWS Network Parameters Measurement Settings Properties Query Clipboard Database Loader Window Browser Messenger Output

264 264 265 266 267 268 269 270 270

MANUAL LAYOUT EDITOR

272

244

209

226

6

Creating a Layout Adding Content to Manual Layout Editor Data Views

WORKBOOKS

272 274

276

ADDING DATA VIEWS

278

ADDING PAGES

282

SAVING A WORKBOOK

284

EXPORTING WORKBOOKS 286 Exporting Workbooks as PDF/MS Word/MS PowerPoint Files Exporting Workbooks as Image Files 287 COPYING A WORKBOOK

288

WORKBOOK PROPERTIES

289

PAGE PROPERTIES

289

EXAMPLE WORKBOOK

290

REPORTS

293

WORKBOOKS

293

SPREADSHEETS

293

REPORTING WITH SPREADSHEET REPORT DESIGNER294 Creating and Opening a Report Template 294 Modifying a Spreadsheet Report Template 298 Showing PDF/CDF Charts in Reports 301 Showing Map Plots in Report Templates 305 Running Reports 308 REPORTING WITH MICROSOFT EXCEL

310

REPORTING WITH CRYSTAL REPORTS Generating Reports Generating Reports from Multiple Files Exporting Reports Configuring Reports

320 320 323 325 326

CREATING CUSTOM QUERIES

329

SQL QUERIES Getting started Nemo Analyze Database Schema Views – Automatically joined tables Database timestamps Filtering log files Value enumeration Connections Correlating tables based on time Guidelines for creating SQL queries SQL VS. KPI Workbench

330 330 330 334 337 338 339 340 341 343 345

QUERY MANAGER Pick Measurement Parameter Generic Query Wizard Manual Query

346 346 351 356

286

CO N TEN TS

7

Correlate Parameters

358

DATABASE BROWSER

358

CUSTOM KPI WORKBENCH 358 Designing Custom KPIs and Adding Input Data Sets 359 Combining Input Data Sets 363 Adding Operations 379 Running and Testing KPIs 410 Saving KPIs as Components 410 Saving Custom KPIs 412 Reopening Custom KPIs for Editing 413 Defining KPI Execution Method and Value Constants 414 Use Case 21.: Creating Complex Filters Using Multiple Conditions 416 Use Case22.: Creating a KPI for Dropped Calls Resulting from a Missing Handover ANALYTICS

447

(S)FTP LOG FILE AUTOLOAD

448

OTHER TASKS

450

EDITING COLOR SETS 450 Importing Color Sets 451 Automatic Generation of Color Sets 452 Use Case 23.: Automatic Generation of Color Set for a Value Range Use Case 24.: Creating a Color Set 461 Use Case 25.: Creating and Applying a Color Set on Map463 Use Case 26.: Creating and Applying a Color Set in Grid467 SCHEDULING EVENTS Report Events Workbook Events Load Folder Events KPI Threshold Alarm Events Defining Recurring Events

472 475 479 480 481 484

TASK MANAGER AND PROBLEM REPOSITORY Configuring and Editing a Task

485 486

MANAGING WORKSPACE WITH PROJECTS

490

MANAGING USERS AND USER GROUPS User Groups

491 493

VIEWING SERVER STATISTICS Managing Tasks

496 497

EDITING OPERATOR SETTINGS

499

EDITING CDMA OPERATOR SETTINGS

501

CONFIGURING NOTIFICATION ICONS Configuring Notifications Using the Parameters view Notification Configuration

503 503 505

MENU EDITOR

506

CONFIGURING SYSTEM SETTINGS Options – Environment Options – Database

510 510 515

457

423

8

Options – Report Options – Color Options – Graph Options – BTS

518 519 520 524

IMPORTING CUSTOM SETTINGS

528

EXPORTING CUSTOM SETTINGS

528

IMPORTING MAPINFO POLYGONS

530

VIEWING LOG ON SYSTEM PERFORMANCE AND SQL FUNCTIONS

USER INTERFACE MENUS Analyze Menu File Menu View Menu Tools Menu Utilities Menu Fleet Menu Google Earth Menu Layout Menu Help Menu

532

533 533 533 534 535 535 536 536 537 537 538

SHORTCUT KEYS

539

TROUBLESHOOTING

540

SOCKET CLOSED DIALOG APPEARS WHEN OPENING NEMO ANALYZE WITH LAPTOP 540

FAQ

541

NEMO ANALYZE SUPPORT

542

INTERNET SUPPORT AND NEMO USER CLUB

542

PHONE, EMAIL, AND FAX SUPPORT

542

APPENDIX 1 MAKING MAPINFO® MAPS Registering a Raster Map

APPENDIX 2 ADDING CSV FILES TO THE DATABASE Opening CSV Files from the Database Opening CSV Files without Database Import Creating Custom Queries for CSV Files

APPENDIX 3 END-USER LICENSE AGREEMENT

544 544 544

546 546 551 553 555

557 557

Q U IC K G U ID E

9

QUICK GUIDE The instructions given in this quick guide have been designed to get you started in a few easy steps. Please, note that these instructions do not give a full picture of the software. Consequently, every step has a cross-reference to the place in the manual where the topic in question will be explained in more detail.

SETTING UP THE SYSTEM 1. Installing the software. Check the manual for hardware requirements if necessary (see Hardware and Software Requirements). Run the Nemo Analyze installation program Nemo Analyze.x.xx.xx.exe from the Nemo Analyze USB flash drive. 2. Loading files to database. Start by loading your measurement and BTS files in the Nemo Analyze database (See Creating the Database). This may take a few minutes, but once files have been added, they will remain in the database until you remove them. 3. You are now ready to start analyzing. You can, for example, generate a report from the data (See Reports) and view measurements in graphs and maps (See Viewing Measurement Data).

10

BEFORE YOU BEGIN Nemo Analyze is a powerful post-processing and reporting tool for planning, optimizing, and maintaining cellular networks. Nemo Analyze serves many purposes from network overview to problem solving and report generation. Some of its features include: • Post-processing of Nemo Outdoor, Nemo Autonomous, Nemo Invex, and Nemo Handy measurement files • Full support for the latest Nemo measurement file format in real time • SQL interface to the database engine • User-defined KPIs with custom queries • Open ODBC interface for third-party software • Fully customizable user interface • Statistical analysis and reporting • Predefined, customizable report templates

END-USER LICENSE AGREEMENT The software described in this book is furnished under a license agreement and may be used only in accordance with the terms of that agreement. For full details of this agreement, refer to page 557.

NOTES Nemo Analyze users must be appropriately trained and should be familiar with the signaling behind wireless technologies depending on their usage needs. The user is expected to have basic knowledge on mobile networks and their terminology. A working knowledge of computers and Microsoft® Windows® is required for using the Nemo Analyze software. The user should know how to use the mouse as well as standard Windows® menus and commands. To review these techniques, see your Microsoft® Windows® documentation.

IN S TAL L IN G N EMO A N AL YZ E

11

INSTALLING NEMO ANALYZE HARDWARE AND SOFTWARE REQUIREMENTS          

PC with Windows® XP Professional/Windows Vista™/ Windows® 7 Pentium III processor or better, minimum 1 GHz, preferably 2 GHz 1 GB RAM minimum 1 GB of free hard disk space for installation and use; 20 GB recommended Nemo Analyze HASP USB key One USB port for HASP USB key Display resolution 1400 x 900 recommended Internet Explorer 8 or newer with Windows XP® Professional Internet Explorer 9 with Windows Vista™/Windows® 7 Crystal Reports Professional edition for creating custom-made report templates (optional)

NEMO ANALYZE INSTALLATION ∇

Installing Nemo Analyze 1. Microsoft® Network Monitor 3.3 must be installed BEFORE Nemo Analyze to enable complete IP/UDP trace details to be displayed in Nemo Analyze. For installing the Microsoft® Network Monitor 3.3, see Installing Microsoft® Network Monitor 3.3 on page 92. If Microsoft® Network Monitor 3.3 is nevertheless installed after Nemo Analyze, Nemo Analyze’s Microsoft® Network Monitor 3.3 functionality can be activated by copying the file NMAPI.dll from the folder C:\Program Files\Microsoft Network Monitor 3\ to the folder C:\Program Files\Anite\Nemo Analyze. If Microsoft® Network Monitor 3.3 is not found on the PC or Nemo Analyze has been installed before Microsoft® Network Monitor 3.3, Nemo Analyze will display only a limited set of IP/UDP trace details. ♦ Note: With PCAP log file decoding, the Microsoft Network Monitor that is installed must be 32-bit, even if the Windows is 64-bit. 2. To begin Nemo Analyze installation, insert the setup USB flash drive into the USB port. ♦

Note: The user performing the installation must have administration rights. Installation without administration rights could result in a database error. If using Windows 7, start installation by right-clicking the setup executable and select "Run as administrator" from the menu.



Note: Before installation, uninstall the previous version of Nemo Analyze using Add/Remove Programs from the Windows Control Panel.



Note: Before installation, if using Windows Vista, it is recommended that User Account Control be disabled. Disable User Account Control by browsing to Control Panel | User Accounts and setting User Account Control (UAC) to OFF. It is also recommended that all Windows Firewall profiles (i.e. Domain Profile, Private Profile, Public Profile) in Windows Firewall with Advanced Security | Properties are set to OFF. 3. Select Run from the Windows Start menu. Type D:\Nemo Analyze\ x.xx.xx.exe and press the RETURN key. This command starts the Nemo Analyze installation software. Follow the instructions given by the installation program.

12

4. Once the installation of Nemo Analyze Setup Prerequisites has been completed, the Welcome to the Nemo Analyze Setup Wizard dialog opens. Click Next.

5. The License Agreement dialog opens. Select I accept the terms of the license agreement, and click Next.

IN S TAL L IN G N EMO A N AL YZ E

13

6. The Custom Setup view opens. Click Browse and select the location where you want to install Nemo Analyze. After this, click Next.

7. The Ready to Install the Program dialog opens. Select Install.

14

8. The Completed the Nemo Analyze Setup Wizard dialog opens. Click Finish and restart the computer.

♦ When starting, Nemo Analyze checks if the database is correct, i.e. has the same version as Nemo Analyze. If the database does not match, a warning is displayed. The warning does not prevent you from using Nemo Analyze but may cause it not to function properly.

IN S TAL L IN G N EMO A N AL YZ E

15

LICENSING For Nemo Analyze you can select between two licensing options: License Server or a HASP USB key.

License Server (Floating License) Licensing is separate from the product itself, therefore four options exist: • • • •

Analyze Standalone with HASP USB key Analyze Standalone with floating license Client/Server (Enterprise) Analyze with HASP USB key Client/Server (Enterprise) Analyze with floating license

The license server option enables the use of floating license, allowing more efficient usage of purchased licenses. When using the floating license, the users do not need to have a physical HASP USB key attached into their PCs. Instead, there is only one physical USB key in the floating license server containing multiple licenses. When Nemo Analyze is started, it reserves a license over the network from the floating license server. Floating license can be used both with Standalone and Client/Server:

16

Unlimited amount of users in different physical locations can install Nemo Analyze, floating license only limits the amount of concurrent users. If the usage pattern of Nemo Analyze is bursty among the users, certain amount of licenses can easily serve 2-4 fold amounts of actual users, since all users are typically never using the SW at the same time. Continuous network connection is needed when floating license is used. In floating license, there is one physical HASP USB key in the floating license server containing multiple licenses. Therefore, Nemo Analyze users do not have a physical HASP USB key attached into their PCs. ♦ Note that the use of network license with the Nemo Analyze Enterprise Edition requires your system to have separate hardware for the Nemo Analyze database server, the license server, and the Nemo Analyze Clients. For database server and license server system requirements, see Nemo Analyze Server Administration Guide. The license server, however, does not have to be dedicated for the license server, i.e. the server can run other services as well.



Installing the floating license server Nemo Analyze requires a HASP USB key during the installation process. In the case of floating license server, The HASP control center run-time SW must be installed to the floating license server first. The server setup can be found from the Nemo Analyze installation USB flash drive or downloaded from the Nemo User Club´s Nemo Analyze section.

1. Plug in the floating license key to the license server computer. You can verify that the installation is OK by going to address http://localhost:1947/ in the floating license server computer with a web browser.

2. You are now able install Nemo Analyze. It should find the floating license key automatically from the network. When installing Nemo Analyze you can go to address http://localhost:1947/ with a web browser on that same computer you are installing Analyze. You should see the floating license key available over the network in the "Hasp Keys" and "Products" sections:

IN S TAL L IN G N EMO A N AL YZ E

17

If you don't see the key in HASP control center, try going to the Configuration section and Access to Remote License Managers page. In the Search Parameters box type the IP address of the license server. Click Submit and wait for a while - the key should appear in HASP Keys section. Also check firewall settings of the license server.

18

3. Start Nemo Analyze. A dialog box informing that the key is not found appears. Type the IP address of the license server into Nemo Analyze. Nemo Analyze will now start with the floating license. ♦ The license server uses a TCP/UDP port to communicate with the computers running Nemo Analyze. Please make sure that communication is allowed in the following port: TCP/UDP 1947.

IN S TAL L IN G N EMO A N AL YZ E



19

Configuring the floating license server. The floating license server can be configured via web browser. The address of the control center is http://localhost:1947/ when accessed from the floating license computer itself. The server can also be accessed over the network: http://:1947/. Currently used licenses can be monitored and disconnected under Sessions. One user utilizes multiple sessions. To force license release of a user, all sessions of the machine must be disconnected. Note that sessions do not map one to one to licenses. One user has multiple sessions, but only one license is consumed per one machine.

Under Configuration, access restrictions for users, logging settings, and remote access setting to the Control center can be configures. Detailed description of the license management interface can be found under Help in the side panel of the Admin Control Center.

20

No Valid License Detected If an error message “Error: No valid license detected….” appears when the application is started, either the HASP USB key is not plugged in or the key is an unsupported model. Please follow the instructions for how to read the license information from the existing HASP USB key. To be able to use the Nemo Analyze application supported by the old HASP USB key, it is recommended that you uninstall Nemo Analyze version 5.80. After uninstallation, reboot the computer and reinstall the previous version. The example above is seen, e.g. when the SPS 00868 key is in use.

HASP USB key Nemo Analyze software license is tied to a HASP USB key and it is not possible to install Nemo Analyze without it. Software-based license is not available. A HASP USB key will be delivered in the Nemo Analyze package. ♦

Note that the new key introduced in Nemo Analyze 6.0 will not be backwards compatible with the older versions of Nemo Analyze. A new key with a valid technical support and maintenance agreement option will be in use with Nemo Analyze 6.0 and later versions. If you have problems starting Nemo Analyze, and if the following error messages appear, please contact Nemo Technical Support at [email protected].



Note: HASP USB keys are not needed when using floating license.

Connecting the HASP USB key in the USB port: Plug the HASP USB key into your computer's USB port. Do not plug the HASP USB key in any other port. It may damage your computer.

IN S TAL L IN G N EMO A N AL YZ E



21

If the following error message appears, please contact Nemo Technical Support at [email protected]. The USB key battery has run out and needs to be changed.

No Valid License Detected If the error message “Error: No valid license detected….” appears when the application is started, either the USB key is not plugged in or the key is an unsupported model. Please follow the instructions for how to read the license information from the existing key. To be able to use the Nemo Analyze application supported by the old HASP USB key, it is recommended that you uninstall Nemo Analyze version 5.80. After un-installation reboot the computer and re-install the previous version.

No Valid Technical Support Agreement If an error message states that the version of Nemo Analyze is not supported by the technical support appears, it means that the HASP USB key type is correct, but that the key is missing valid technical support & maintenance agreement information. Please follow the instructions for how to read the license information from the existing key with the Remote Update Utility. To be able to use the Nemo Analyze application supported by the HASP USB key without information about the technical support agreement, it is recommended that you uninstall Nemo Analyze version 5.80. After un-installation reboot the computer and re-install the previous version.

The old HASP USB key

The new HASP USB key

The HASP USB keys are updated using the Remote Update Utility software. Before updating Nemo Analyze application please make sure that new key is available. Note that you must use the latest version of the software which comes with Nemo Analyze version 6.00, or it can alternatively be downloaded from Nemo User Club. See the instructions below for updating your Nemo Analyze USB key.

22

∇ Updating the HASP USB key (Nemo Analyze version 5.80 and later) 1. Connect your HASP USB key and start the SecureUpdate by selecting Start | All Programs | Nemo Tools | Remote Update Utility. 2. The Collect Key Status Information tab opens.

3. Click Collect Information. If the Select HASP Key dialog appears, select the HASP HL item and click OK.

4. Define the location where the C2V file is saved and send the C2V file to Nemo Technical Support at [email protected]. Please add the following information to the e-mail using the following subject “Nemo Analyze HASP USB key update”:

IN S TAL L IN G N EMO A N AL YZ E



Company name



First name



Surname



Street address



Zip/ Postal Code



Country



Telephone number



Mobile number

23

5. After you have received the V2C file containing the update, select the Update File in the Apply License Update tab and click Apply Update.

6. The HASP USB key is now updated. Nemo Analyze can be installed and is ready for use.

24

Technical Support Expiration The new dongle keys used with Nemo Analyze 6.0 and later versions include a compulsory technical support and maintenance agreement option. The technical support expiration date defines the date the agreement ends. After this date it is not possible to start the new version of the Nemo Analyze application. For example: A customer has purchased Nemo Analyze version 6.0 with a 1-year technical support maintenance agreement in October 2011. The customer is entitled for free updates until October 2012. Nemo Analyze versions released after October 2012 cannot be used with the dongle key without renewing the technical support & maintenance agreement. After the technical support & maintenance agreement is renewed, the dongle key can be updated remotely and the customer can update the application to the latest version.

S T AR TIN G N E MO AN AL YZ E

25

STARTING NEMO ANALYZE After running Setup, you will see a new Nemo Tools program group under the Programs selection in the Windows® Start menu.



To start Nemo Analyze: 1. Double-click the Nemo Analyze.exe icon in My Computer or select it from the Start menu (StartProgramsNemo ToolsNemo Analyze). 2. When Nemo Analyze is starting, hold down the Shift key to prevent Nemo Analyze from loading a previously used workspace. 3. When the program starts, the window below will open. In the Welcome to Nemo Analyze workbook you will find useful information about Nemo Analyze, links to related documents, and shortcuts to loading measurement and BTS files.

Ribbonbar

Workspace

Parameters view

Workbook area

26

USING NEMO ANALYZE In Nemo Analyze you can view measurement data in multiple ways. The most convenient way, however, is to focus on the Workspace user interface since it is quick and easy. For example, in the workspace you can double-click a parameter, and Nemo Analyze opens the parameter automatically in the default data view. Furthermore, you can go to View | Workbook | Add Data View, choose a particular data view, select a measurement, and drag a parameter from the Parameters view in the data view. You can also view several parameters in the same data view by dragging them in it. If you drag a parameter in an empty workbook, a dialog box appears and asks you to select a data view type. If you drag a measurement file to a workbook with a data view, a dialog box emerges asking you to select the parameter you wish to view. The filter field above the Parameters view is useful when looking for a specific parameter in a long list. All data views are synchronized with each other based on time. Consequently, if you open two or more data views on the same measurement file but on different parameters simultaneously, and switch from one point of time in one data view to another point in time, the data in the other data views change accordingly.

CR E A TIN G TH E D A T A B A S E

27

WORKSPACE The Workspace forms the basis of the user interface in Nemo Analyze. All measurements and parameters can be found in the workspace, and from there it is convenient to drag them in various data views. See also Using Nemo Analyze. The Workspace view is by default attached to the left-hand side of the Analyze main window. You can also drag it elsewhere in the window, and if you want to dock it back to the side of the main window, double-click on the Workspace. The Workspace view consists of five pages: Measurements, Base Stations, Maps, Polygons, Data Source Files, and Reports pages, respectively. You can switch between these pages via the icon tabs at the bottom of the Workspace view. The Measurements page in the Workspace is divided into three sections: Folders, Measurements, and Parameters. The folders include the All Measurements folder, which shows all the files that are currently in the database, and other user-defined folders. The current database connection is also identified next to the All Measurements folder, e.g. Analyze Local Database. Measurements displays a list of all measurements in the folder selected in the Folders section. The name of the measurement device is also displayed when the mouse is hovered over a measurement file. Parameters shows all available parameters and KPIs for the selected file, measurement, or folder, depending on the selections in the other two sections. The KPIs can be displayed in graphs, maps, and other data views, and statistics can also be calculated from the Parameters view.

You can add parameters to Favorites by right-clicking on a parameter and selecting Add to Favorites from the popup menu. To toggle between the Favorites view and the Parameters view, click the Favorites

button in the upper right corner of the Parameters view.

28

CR E A TIN G TH E D A T A B A S E

29

EXPORTING/IMPORTING FAVORITE PARAMETERS It is possible to export and import favorite (starred) parameters by exporting/importing identifiers of all favorite parameters. To Export favorite parameters, select File | Settings. The Save As dialog opens. Name the file and click Save. The Export Settings dialog opens.

Select the parameter favorites you want to export and click OK. To import parameter favorites, select File | Settings. The Open dialog opens. Open the export file (*aex) where you have saved the exported favorite parameters by selecting Open.

30

Select the parameter favorites you want to import and click OK. A dialog box appears asking if you want to replace existing favorites.

If user selects Yes, all favorites are cleared and new ones are imported. If user selects No, existing favorites are remembered and imported ones are added.

CR E A TIN G TH E D A T A B A S E

31

WORKSPACE FILTERS Workspace filters enable the user to locate measurement files, parameters, maps, base stations, etc. more quickly. Below you can find some usage examples for the filters. Above the measurement files you can find the filter for measurement files. Type the name of the measurement file in the filter field to find the desired measurement file. Above the Parameters view you can see the filter field for parameters. Type in the name of the parameter, and only parameters matching the name will be viewed in the Parameters view.

32

In the Base Stations view of the Workspace, the filter can find base stations based on any content in the BTS file, allowing base stations to be filtered based on e.g. channel number.

CR E A TIN G TH E D A T A B A S E

33

CREATING THE DATABASE When you start Nemo Analyze for the first time, the database is empty. Adding files - measurements, BTS files, and maps - to the database may take a while, but once files have been added, they will remain in the database until you remove them. For instruction on how to add CSV files to the database, see APPENDIX 2.

ADDING FILES TO THE DATABASE Select File | Measurement | Open [Measurement /Map/BTS/Report/Data Source File].

The Open dialog opens.

Select the file(s) you want to add to the database and click Open. You can select several files by holding down the Shift key.

34

From the Files of type drop down menu you can define the type of file that you want to open. Supported network measurement tools of Nemo Analyze include Nemo Outdoor, Nemo Autonomous, Nemo Handy, Ascom TEMS Investigation, Ascom TEMS Pocket, Ascom TEMS Symphony Suite, EADS REMS TETRAPOL, and R&S ROMES. Measurement data in CSV (Character-Separated Value) ASCII format is also supported. Marker file and map are loaded automatically from Nemo Handy embedded indoor file when downloading the file to Nemo Analyze. ♦ Note that adding files to the database may take several minutes depending on the number and the size of the files. ♦ Note that all the files need to have unique file names. ♦ Note that the file names of Nemo measurement files must follow the format filename.devicenumber.nmf (for example, t5gsm.1.nmf). Device number signifies the number of the device in case of simultaneous measurements with multiple devices. Device number must always be separated with an extra dot in the file name. With one device, the value is 1. ♦ Note that the marker file and map are loaded automatically from Handy embedded indoor file when downloading the file to Analyze. The Database Loader (see Database Loader) displays the progress of file upload, file conversion, and file upload queue. The added measurement files will appear in the All Measurements folder in the Workspace | Folder Contents view in the left-hand side of the Nemo Analyze main window.

Migrating Nemo Analyze database to a new laptop When changing your laptop, it is possible to migrate existing Nemo Analyze database to the new laptop once you have Analyze already installed on it. To achieve this, copy the following two subfolders from Nemo Tools folder on the C: • •

Nemo Analyze, with the exception of the Logs folder under Nemo Analyze (DO NOT copy the Logs folder or the database might get corrupted), and Nemo Analyze Datastore

CR E A TIN G TH E D A T A B A S E

35

Importing Image Files as Maps In addition to adding map files in the database through File | Measurement | Open Map, you can import image files to be used as maps. Select File | | Import | Image as map. In the Open dialog, select the image that you want to use as a map. It can be, for example, a floorplan from a test site. After selecting the image file you need to define either the width and the length of the map area in meters, or the GPS coordinates for two map corners. After you click OK in the Map Import Parameters dialog, the map is added in the database and it will appear in the Maps folder in the workspace.

36

You can also create black and white copies of raster maps by right-clicking on a map in the workspace and selecting Create Black & White Copy. The map is saved with the same name with ‘BW’ added at the end of the file name.

CR E A TIN G TH E D A T A B A S E

ORGANIZE MEASUREMENTS By default, all added measurement files go into the All Measurements folder.

37

38

If you have a lot of files, it may be convenient to categorize measurement files into custom-made subfolders. In the Organize Measurements dialog you can conveniently handle and organize large sets of measurement files. Go to File in the Ribbonbar and select Organize, or right-click on the All Measurements folder in the Workspace and select Organize.

In the Organize Measurements dialog you can create new folders and subfolders, make joined measurements, and remove files from drag & drop folders. Right-click on a folder in the left-hand panel to create new folders. See the following chapters for information on the different folder types.

CR E A TIN G TH E D A T A B A S E

39

Select measurements, right-click on them, and click the Join measurements button on the Tools toolbar to create joined measurements. See Joined Measurements for more information on joined measurements.

You can also organize measurements in the Workspace. Right-click on the All Measurements item and select Add Folder.

There are four types of folders you can add: Drag & Drop, Search, Query, and Voice Quality.

40

Drag & Drop Folders Drag & Drop folders are folders where you can drag files from the All Measurements folder. You can organize files, for example, by technology, time or place. When you drag and drop files from the All Measurements folder to the custom-made sub-folders, the files are only copied, i.e., the files will appear in two folders. The drag & drop folders are identified with a symbol.

The example shows a Workspace with two custom-made drag & drop folders named October 2006 and CDMA2000. The CDMA2000 folder has two files, and the October 2006 folder has four files. The same files are also in the All Measurements folder.

CR E A TIN G TH E D A T A B A S E

41

Search Folders Search folders are folders where files are copied based on user-defined search criteria. The search folders are identified with a symbol. To create a new search folder, right-click on the All Measurements folder, and select Add Folder | Search… from the popup menu.

If you have an existing search folder and you have loaded new files to the database, you must refresh the folder to display also the newly added files. To refresh a folder, right-click on the folder, and select Refresh from the popup menu.

The Search Folder Properties dialog opens, allowing you to define search criteria for the folder using the Measurement, Notifications, Network and System tabs. You can combine multiple search criteria and create search folders for, e.g., WiMAX scanners from specific dates and from specific polygon-defined geographical area.

42

Name defines the search folder name.

Title, extension and description options allow you to search for specific measurement files based on the filename, file extension, and file description. Device type enables you to search for mobile or scanner measurements. Area enables you to search for measurements made on a defined area. To define the area, click the Define Area button. This opens the Select Polygon Area dialog below.

Clicking the Define Area button on the Properties dialog Measurement tab (see above) opens the Select Polygon Area dialog.

CR E A TIN G TH E D A T A B A S E

43

With Map | Filename you can select or browse for the map file you want to use. With Area | Name you can select a polygon area you have previously saved. With the Save, Save As and Delete buttons you can save an edited polygon area, save and name a new polygon area and delete a previously saved polygon area. With Change Map you select another map. Reset Area removes the polygon selection.

44

When you right-click on the map, a popup menu opens. With Area selected, you can select a polygon area.

Size of measured area defines the size of measured area in square kms.

Start date and End date allow you to define a time range from which all measurement files will be searched.

CR E A TIN G TH E D A T A B A S E

45

Search last allows you to search a defined number of the most recent measurement files based on the following parameters: Days, Weeks, and Months finds measurement files from an N number of previous days, weeks, and months. Measurements finds measurement files from an N number of the most recent measurement sessions. Duration allows you to search for specific measurement files based on their duration. Hour from N to N allows you to filter files based on the hour of day when they were recorded

In the Notifications page you can select the events you want to include in the search.

With the Mobile country code option you can search for measurements made in a certain country. With the Mobile network code option you can search for measurements made in a certain network.

46

With the System option you can search for measurements made in a certain system. With the Band option you can search for measurements made in a certain band.

With the Tested Applications option you can perform searches based on tests performed in the log file.

CR E A TIN G TH E D A T A B A S E

47

Finally click OK and the measurements that match the search criteria are copied to the search folder.

Hiding Folder Content When there are 20000+ log files in the database, it is recommended to hide folder content to improve the responsiveness of the Nemo Analyze user interface. To hide folder content, right-click on the All Measurements folder and select Hide Folder Contents from the popup menu.

48

Query Folders Query folders are folders where files are added based on user-defined criteria, that is, queries. Once the query is defined, Nemo Analyze will go through the measurement files in the database and automatically add all relevant files to the query folder. To create a new query folder, right-click on the All Measurements folder and select Add Folder | Query from the popup menu.

CR E A TIN G TH E D A T A B A S E

49

If you have an existing query folder and you have loaded new files to the database, you must refresh the folder to display also the newly added files. To refresh a folder, right-click on the folder, and select Refresh from the popup menu.

The Properties dialog opens. In the Query field, select the criteria according to which the files will be copied to the folder, e.g., Last Year. The folder will be named automatically, but if you wish to name the folder manually, clear the option and type a name. Click OK.

50

Nemo Analyze creates the new folder, and the files that match the query criteria are copied to the folder. The query folders are identified with a symbol.

The example shows a Workspace with one custom-made query folder named Last Year.

CR E A TIN G TH E D A T A B A S E

51

Voice Quality Folders Voice quality folders can be used to automatically find the server side log files of selected mobile log files. Note that displaying the UL MOS of a selected mobile log file is done automatically; this feature is not needed for that purpose. See Use Case 2.: Viewing Uplink Voice Quality Server Data. To create a new voice quality folder, right-click on the All Measurements folder and select Add Folder | Voice Quality from the popup menu.

The Properties dialog opens. The folder will be named automatically, but if you wish to name the folder manually, clear the option and type a name. Select mobile measurements for which to find corresponding voice quality server files through the Browse button and click OK.

52

Refresh All Folders To refresh all folders, right-click on the All Measurements folder and select Refresh All Folders from the popup menu.

CR E A TIN G TH E D A T A B A S E

53

JOINED MEASUREMENTS With Nemo Analyze it is possible to join separate measurement files into a single joined measurement. Joined measurements will be handled as one measurement file. ♦ Note that you cannot join overlapping measurement files. Files must have been recorded at different times.

54

Right-click on All Measurements and select Add Joined Measurement.

In the Add Joined Measurement dialog, type a name for the joined measurement, e.g., 18 Jun 2006.

CR E A TIN G TH E D A T A B A S E

55

The joined measurement appears in the Workspace | Folder Contents. You can now drag & drop measurement files into the folder in the Folder Contents section. Joined measurements are identified with a symbol.

It is also possible to remove all measurements from the joined measurement file by right-clicking on the joined measurement file and selecting Remove All Joined Measurements.

ADDING DESCRIPTIONS TO MEASUREMENT FILES AND FOLDERS Custom descriptions can be added to measurement files and folders. These descriptions can be used, for instance, to further individualize particular files or folders for the purposes of later searches. To add a description, right-click on the file or folder, and select Set Description from the popup menu.

56

The Measurement Description dialog opens.

Enter the description to the Measurement file description field and click OK. The description is displayed as a tooltip when hovering over the measurement file or folder. Measurement files and folders can also be searched based on the description using Search Folders (see page 41). To add a description to several measurement files or folders, right-click on the measurement files or folders while holding down the shift key, and select Set Description from the popup menu. To edit an existing description, right-click on the measurement file or folder and select Set Description from the popup menu.

CR E A TIN G TH E D A T A B A S E

57

DELETE FOLDER CONTENTS To permanently delete the contents of a particular folder from the database, right-click on the folder and select Delete Folder Contents from the popup menu.

The following prompt appears.

Select Yes to permanently delete the measurement files from the database.

RETRIEVING ORIGINAL FILES FROM THE DATABASE ♦

Note: This feature is supported by Nemo Analyze Enterprise Edition only.

To retrieve original measurement files from the database, right-click on a measurement folder or file in the Workspace, and select Retrieve Original Files from the popup menu.

58

The Retrieve Files dialog opens.

Retrieve to folder defines the folder to which the retrieved files will be saved. Retrieving file displays the file that is currently being processed. File N/NNN displays the progress of the retrieval process. Retrieve begins the retrieval process. Define a target location for the retrieved files with the Retrieve to folder control and click the Retrieve button.

CR E A TIN G TH E D A T A B A S E

DATABASE CLEANUP To clean up old files from the database, right-click on All Measurements in the Workspace and select Clean Up from the popup menu.

The Clean Up dialog opens.

Define the time range from which the measurements are to be deleted and click Delete.

59

60

VIEWING MEASUREMENT DATA Measurement data can be viewed in different kinds of data views, such as graphs, grids, numerical views, and maps. A workbook is a collection of data views and Nemo Analyze offers some readymade workbooks for analyzing measurement data. You can also easily make your own workbooks and save them for later use.

PARAMETERS The fastest way to view measurement data is through the Parameters view. To open a parameter in its default view, select the relevant measurement files in the Workspace and then double-click a parameter in the Parameters view.

M AN AG ING W O R KBO O KS

61

The selected parameter is opened in the default view. If you want to open the parameter in some other type of view, right-click on a parameter in the Parameters view and select the view type from the popup menu.

You can also drag and drop parameters in data views from the Parameters view. Nemo Analyze will display a green icon if the data view is suitable for the parameter, and a red icon if the data view is unsuitable. In the Parameters view you can search and filter parameters by typing the parameter name in the field at the top of the Parameters view. The Parameters view will display only the defined parameters.

62

Some parameters require further definition before they can be viewed in any given data view. When opening these parameters in a data view, a dialog box appears asking for specifications applicable to the selected parameter. For example, if you want to view RX level full selected BSIC in a graph, in the Fill Parameters dialog you can select a BSIC value from the drop-down menu in the Value field. Click Finish, select the graph type, and the parameter is displayed in a graph according to the BSIC specifications.

The RX level full parameter values are shown according to BSIC value 18.

M AN AG ING W O R KBO O KS

63

Statistics/Statistics with filters over Parameter In addition to running reports on measurement files, it is also possible to run statistics on a single parameter straight from the Parameters view. The statistics and statistics with filters can be run over a single measurement file, or over a folder containing several measurement files (e.g., the All Measurements folder). You can run parameter statistics over a single measurement file by accessing the Parameter Launchpad. To do this, select a measurement file in the Workspace, select a parameter in the Parameters view, and click on the button displayed at the bottom left corner of the Parameters view. For more information on the Parameter Launchpad, see page 69. Alternatively, you can run statistics over a single measurement file by selecting a measurement file in the Workspace, then right-clicking on a parameter in the Parameters view, and selecting Statistics By or Statistics With Filters By.

Statistics by/Statistics with Filters by: No Grouping To run statistics over a single measurement file without grouping the data in any way, select a measurement file in the Workspace, right-click on a parameter in the Parameters view, and select Statistics by | No Grouping. To run statistics with filters over a single measurement file without grouping the data in any way, select a measurement file in the Workspace, right-click on a parameter in the Parameters view, and select Statistics With Filters By | No Grouping.

64

M AN AG ING W O R KBO O KS

65

Below is a workbook with statistics on RSCP best active set when run on a single file, based on No Grouping.

Benchmarking can be done by dragging parameter statistics on different files or folders in the same graph.

66

Statistics by: Fixed Geographical Bin Area Statistics by Fixed Geographical Bin Area and Bounding Geographical Bin Area make it possible to view statistics on map in area bins. With Fixed Geographical Bin Area, the user can select an area (e.g. a portion of the measurement route) and perform area binning on it. With Bounding Geographical Bin Area, area binning will be automatically performed on the entire measurement route. To produce statistics by fixed geographical area, select a measurement, right-click on a parameter, and select Statistics by | Fixed Geographical Bin Area. The Select Rectangular Area dialog box appears.

Select a map in the Map | Filename field, and define the area on the map which you want to include in the query with your mouse. The area binning statistics are calculated using linear math. Because of this, it is possible that with low zoom levels and non-linear map projections the results do not plot correctly on the map. This is most apparent when using a map of the whole world or continent. With city level maps the results are generally very accurate. Click OK. The bins show the average value according to the color set in each bin.

M AN AG ING W O R KBO O KS

67

It is also possible to view statistics based on Minimum, Maximum, Sample count, Std. deviation and Variance. The statistics are by default calculated based on Average. Go to the side panel, right-click on the parameter in the Layers view, and select Properties from the popup menu.

The Properties dialog opens.

Select a statistics type from the Statistics drop-down menu and click OK.

68

The area binning layer is drawn based on the selected statistics type.

Statistics by: Bounding Geographical Bin Area Statistics by Fixed Geographical Bin Area and Bounding Geographical Bin Area make it possible to view statistics on map in area bins. With Fixed Geographical Bin Area (see page 66), the user can select an area (e.g. a portion of the measurement route) and perform area binning on it. With Bounding Geographical Bin Area, area binning will be automatically performed on the entire measurement route. To produce statistics by bounding geographical bin area, select a measurement, right-click on a parameter, and select Statistics by | Bounding Geographical Bin Area. It is also possible to view statistics based on Minimum, Maximum, Sample count, Std. deviation and Variance. The statistics are by default calculated based on Average. Go to the side panel, right-click on the parameter in the Layers view, and select Properties from the popup menu.

The Properties dialog opens.

Select a statistics type from the Statistics drop-down menu and click OK. The area binning layer is drawn based on the selected statistics type.

M AN AG ING W O R KBO O KS

69

Parameter Launchpad To produce parameter statistics, such as Cumulation & density, Count, Average, Minimum, Maximum, Standard deviation, Variance, Mode, Median, Midrange, and Histogram, based on measurement data, select a parameter and click on the view.

button displayed at the bottom left corner of the Parameters

70

The Parameter Launchpad view opens. Open in data view opens the parameter with the settings defined in the sections Presentation, Statistics and Details. Apply filters, if selected, opens a dialog for defining filters for the parameter after you have defined all the parameter settings and selected Open in data view. Open in defines the data view type used in displaying the parameter data. Statistics (see below) Details displays the parameter description if it exists. Change defaults enables you to change parameter default settings using the Change Defaults dialog (see p. 63).

From the Statistics submenu, you can open various parameter statistics in spreadsheet format. To include more than one parameter statistics type on the same spreadsheet, drag and drop each statistics type on the spreadsheet. Available statistics types include Cumulation & density, Count, Average, Minimum, Maximum, Standard deviation, Variance, Mode, Median, Midrange, and Histogram. Apply filters, if selected, opens a dialog for defining parameter filters once the parameter is dragged and dropped onto a data view. Weight by defines whether the statistics are to be weighted by distance, by time, or by sample (no weight). Group by defines how the statistics are to be grouped.

V IEW ING M E ASU R E M EN T D A T A

71

Change Defaults Through the Parameters view you can change the default color set and default graph scales for each parameter. Right-click on a parameter and select Change Defaults. Alternatively, you can also change defaults using the Parameter Launchpad (see Parameter Launchpad).

The General tab of the Change Defaults dialog enables you to select a default color set for the parameter, select the image, and set the graph scale top and bottom values.

72

The View tab of the Change Defaults dialog enables you to set the default data view for the parameter.

The Drill down tab of the Change Defaults dialog enables you to select the drill down workbook that is being used by default when double-clicking on a parameter in the Parameters view.

The CSV tab of the Change Defaults dialog enables you to choose if selecting map output preference is available for a CSV file parameter.

V IEW ING M E ASU R E M EN T D A T A

73

If this option is selected, when double-clicking on a CSV file parameter in the Parameters view and selecting Open In Map, the Select Columns dialog opens, allowing you to select Route or Route Coloring to be shown on the map. If the option is not selected, the Select Column dialog will not appear.

74

VIEWING MEASUREMENT DATA IN GRAPHS This use case describes the steps for viewing measurement data in various graphs. It is assumed that there are measurement files in the database. Select a measurement in the workspace. You can locate a measurement file quickly by typing the name of the measurement file in the Filter field, which is marked by the red frame below. This filtering functionality for measurement files in the Workspace is especially useful with a large number of measurement files in the database, or in a specific folder. Select a measurement in the Workspace, right-click on a parameter and select Open | In, e.g. Graph.

In the Choose Graph Type dialog, select the graph type in which you want to show the parameter, in this case a line graph.

V IEW ING M E ASU R E M EN T D A T A

The BLER parameter is opened in a line graph.

75

76

VIEWING MEASUREMENT DATA ON MAP This use case describes the steps for viewing measurement data on map. For the purposes of this use case, it is assumed that there are measurement files with coordinates, BTS files, and corresponding maps in the database. For loading files to the database, see Adding Files to the Database on page 33.

Changing default map To change default map (displayed in bold), right-click on the map file name on Workspace view and select Default Map from the menu. ´

V IEW ING M E ASU R E M EN T D A T A

77

Opening Measurement Files on Map In the Maps Folder of the Workspace window, double-click on a map (.tab) or Geoset (.gst) file. The map file is loaded to the Analyze database. Now double-click on the map file in the Loaded view.

78

The map view opens.

For adding more map layers to map view, see Use Case 11.: Adding Map Layers and Saving Layer Combinations as Geosets on page 196. Go to the Measurement file page in the Workspace view, and select a measurement file. Then select a parameter from the Parameters view, and drag it on the map.

V IEW ING M E ASU R E M EN T D A T A

79

80

The measurement is shown on the map.

The route is opened on the map and colored using the default color set for the selected parameter. You can zoom in and out on the map with the mouse wheel. The side panel displays the selected color set.

V IEW ING M E ASU R E M EN T D A T A

81

Opening BTS Files on Map Click the base station icon the Base Stations view.

at the bottom of Workspace to switch from the Measurements view to

Drag a BTS file from the Workspace to the map.

Click OK when Nemo Analyze asks if the added BTS should be associated with the route. The base station icons are drawn.

82

To change the parameter color set used for coloring the BTS icons, right-click on the BTS layer in the side panel under Layers, and select Properties.

The Properties dialog opens. Select the Color tab, change the setting of both Parameter and Color set drop-down menus, and click OK.

V IEW ING M E ASU R E M EN T D A T A

The BTS icons are colored based on the selected color set.

83

84

Viewing Notification Icons on Map Notification icons enable specific measurement events to be viewed on map. Right-click on the route layer in the side panel (or directly on the measurement route on map) and select Properties from the popup menu.

The Properties dialog opens. Go to the Notifications tab. Select all notifications that you are interested in. For example, we might want to view Cell reselections.

Select the notifications you want to be displayed and click OK.

V IEW ING M E ASU R E M EN T D A T A

85

If the selected notifications occur in the measurement file, they are drawn on the map as small icons.

You can now zoom in on the map and move the current location marker on the notifications. If all the different views (line graphs, grids, maps, etc.) are synchronized, all data views will jump to the same point in the measurement, allowing you to analyze all relevant parameter data before, during and after the notification was logged.

86

Use Case 1.: Viewing Cell Footprints, RSCP Footprints, and LTE Footprints Nemo Analyze can automatically create a cell footprint, an RSCP footprint, or an LTE footprint map plot for every cell measured. Cell/RSCP/LTE footprint is displayed for every cell whose signal has been among the three strongest at some point during the measurement session. The footprint of each cell is displayed on map on a separate page, allowing you to browse from footprint to another and immediately see both the footprint and the cell. Cell footprint/RSCP/LTE analysis can be performed on both UMTS scanner and mobile data. Analysis will not work properly if there will be hundreds of pages in the results. Therefore, it is advisable to use filters to limit the amount of results. To view cell/RSCP/LTE footprints, right-click a measurement file in Workspace | Measurements | Folder Contents, or a measurement folder in Workspace | Measurements | Folders, and select Analyses | Ec/NO Cell Footprints (mobile) / Ec/NO Footprints (scanner) / RSCP Cell Footprints (mobile) / RSCP Cell Footprints (scanner) / RSRP Cell Footprints (mobile) / RSRP Cell Footprints (scanner) / RSRQ Cell Footprints (mobile) / RSRQ Cell Footprints (scanner) from the popup menu.

V IEW ING M E ASU R E M EN T D A T A

A dialog box allowing you to choose between Scrambling code filter and Channel number filter appears. You are also able to select if the color legend and the entire route is shown.

Select the filter of your choice and click OK. The footprints view opens, displaying the footprint of each cell as a separate page.

You can browse from cell to cell by selecting pages from the tabs below the map view.

87

88

Use Case 2.: Viewing Uplink Voice Quality Server Data This use case describes the steps for viewing uplink voice quality server data together with mobile terminal (downlink) data from the same measurement session.

Step 1: Loading Voice Quality Measurement Data into the Database Nemo Analyze correlates the UL MOS scores automatically from the server log file to the mobile log file. A prerequisite for this functionality is that both files are loaded into the Nemo Analyze database, and that the time in server and mobile log files is synchronized in the log files. This can be accomplished by using GPS time in the measurement tool and in the server using time synchronization services available online. See Nemo Server and Nemo Outdoor or Nemo Handy User Manuals for more information. Time synchronization can also be done manually. In time synchronization, an accuracy of around three seconds in the time sync is sufficient. To load an uplink voice quality measurement session into the database, select File | Measurement | Open Measurement from the Ribbonbar. The Open dialog opens.

V IEW ING M E ASU R E M EN T D A T A

89

Select both the server measurement file and the mobile terminal measurement file. You can do this (by holding down the Shift key while selecting the files. Once both files have been selected, click Open. ♦ Note: In order for the uplink server data to be displayed correctly, the database must contain both the server (UL) measurement file and the mobile terminal (DL) measurement file. Nemo Analyze will correlate these files automatically. The files are loaded into the database. You can monitor loading progress by using the Database Loader (see page 268).

Step 2: Running Queries on Uplink Voice Quality Server Data Once both files have been loaded into the database, select the downlink mobile terminal file (i.e. do not select the uplink server file) in the Workspace, right-click on a relevant audio quality parameter, and right-click on a relevant audio quality parameter and select Open In | [Data view].

90

A workbook is opened based on the measurement file.

V IEW ING M E ASU R E M EN T D A T A

91

92

Use Case 3.: Viewing IP/UDP Packet Trace Data ♦ Note: Microsoft® Network Monitor 3.3 must be installed BEFORE Nemo Analyze to enable complete IP/UDP trace details to be displayed in Nemo Analyze. For installing the Microsoft® Network Monitor 3.3, see Installing Microsoft® Network Monitor 3.3 below. ♦ Note: If Microsoft® Network Monitor 3.3 is nevertheless installed after Nemo Analyze, Nemo Analyze’s Microsoft® Network Monitor 3.3 functionality can be activated by copying the file NMAPI.dll from the folder C:\Program Files\Microsoft Network Monitor 3\ to the folder C:\Program Files\Anite\Nemo Analyze. ♦ Note: If Microsoft® Network Monitor 3.3 is not found on the PC or Nemo Analyze has been installed before Microsoft® Network Monitor 3.3, Nemo Analyze will display only a limited set of IP/UDP trace details. With IP packet capturing, network packets sent between IP addresses are stored in log files and can be post-processed with a third party application such as Ethereal®. The IP packet data is stored in a separate file (.pcap) for each measurement terminal for which IP capturing is enabled. This use case describes the steps for viewing IP trace data based on a measurement file and the corresponding IP trace (.pcap) file. Both files must be from the same measurement session with identical time stamps. First, a relevant workbook (e.g. HSDPA full details) is opened on the measurement file. Next, a separate workbook on the IP trace file corresponding with the measurement file. The two workbooks are automatically synchronized, enabling the correlation of events on the parameter level with events on the IP trace level. ♦ Note: In order for the synchronization of the two files to work, the time stamps of the measurement file and the IP trace (.pcap) file must be identical, i.e. both files have to be from the same exact measurement session.

Step 1: Installing Microsoft® Network Monitor 3.3 Go to Microsoft website at to download the free Network Monitor installation package. Select the NM33_x86.exe installation file and click the Download button. Once the installation file has been successfully downloaded, double-click on the file.

V IEW ING M E ASU R E M EN T D A T A

The Open File – Security Warning dialog opens.

Select Run. The Microsoft Network Monitor 3.3 dialog box opens.

Click Yes to continue installation. The Microsoft Network Monitor 3.3 Setup – Welcome… dialog opens.

Click Next. The Microsoft Network Monitor 3.3 Setup – End-User License Agreement dialog opens.

93

94

Select I accept the terms in the License Agreement option and click Next.

The Microsoft Network Monitor 3.3 Setup – Choose Setup Type dialog opens.

Select Typical.

The Microsoft Network Monitor 3.3 Setup – Ready to Install dialog opens.

V IEW ING M E ASU R E M EN T D A T A

95

Select Install. Once the installation procedure has finished, the Microsoft Network Monitor 3.3 Setup – Completing the Setup Wizard dialog opens.

Select Finish.

96

Step 2: Open a Workbook Based on a Measurement File Open a workbook based on a measurement file by right-clicking on the measurement file in the Device Menu and selecting a relevant workbook (e.g. HSDPA full details) from the popup menu.

A workbook is opened based on the measurement file.

V IEW ING M E ASU R E M EN T D A T A

97

Step 3: Load IP Trace Files (.pcap) into the Database Next, select the IP Traces icon from the panel below the Parameters view. The IP Traces page of the Workspace opens. If there are no IP trace files on the IP Traces page, right-click on the page background and select Open from the popup menu.

The Open dialog opens.

Browse for .pcap files, select the files you want to load to the database, and click Open.

98

Step 4: Open an IP Trace Information Workbook Based on the Corresponding IP Trace File (.pcap) The IP Traces page displays all .pcap files stored in the database. Double-click on the IP trace file that corresponds with the measurement you opened the measurement file workbook based on in Step 1.

The IP trace file is opened in a separate IP trace information workbook that is automatically synchronized with the measurement file workbook.

V IEW ING M E ASU R E M EN T D A T A

99

Step 5: View Synchronized Measurement and IP Trace Data Go to the measurement file workbook and select an event that is of interest to you (e.g. a point in time where Throughput suddenly drops).

Switch back to the IP trace workbook and observe the IP trace messages surrounding the selected event (i.e. the possible problem causes on the IP level).

10 0

PARAMETER FILTERING It is also possible to filter all parameters based on, for example, time and region. Select a measurement file, right-click a parameter in the Parameters view, and select Open With Filters in | [dataview]. Here we will use L3 signaling as an example.

V IEW ING M E ASU R E M EN T D A T A

10 1

An empty workbook, and the Fill Parameters dialog box to define the filtering criteria appear.

In the Fill Parameters dialog you can further limit the query results by adding different filters. Filters can be applied to parameters that are part of the query.

10 2

In this case, Data transfer direction with the value 1 is added.

Click Next. A grid with the parameter according to the specifications appears.

V IEW ING M E ASU R E M EN T D A T A

10 3

Filtering Based on Polygon Area With parameter filtering it is also possible to limit a query based on a user-defined area, i.e. by Polygon area selection. As a consequence, the results of a query will be limited to a user-defined part of a measurement route in the chosen data view. This is useful, for example, when you want the values of a parameter to be viewed with a value-based color set only on a part of the route on a map. In this case, the rest of the measurement route will be colored with a default color. In this example we will select Ec/N0 best active set as the parameter. Select a measurement file in the Workspace and type Ec/N0 best active set in the Parameters view filter field. Right-click on the parameter and select Open With Filters In | Map.

10 4

An empty workbook and the Analyze Wizard - Fill Parameters dialog box appear. In the dialog box select Area under Name, and press the … tab.

The Select Area dialog box appears. Select a map in the Filename field, or load one through the browse button. Next, define an area on the map using the left mouse button. The Save As button enables you to save the map with the selected area for later use. Click OK.

V IEW ING M E ASU R E M EN T D A T A

10 5

The Analyze Wizard – Fill Parameters dialog box appears. Click Finish.

A new workbook opens. The measurement route on the map is colored with the Ec/N0 color set over the section of the route specified with the polygon area. The rest of the route is colored with the default color, here blue.

10 6

Use Case 4.: Global Parameter Filtering Based on a Secondary Parameter Service providers often define the extent of coverage area using a specific parameter as a threshold value. In Nemo Analyze, it is possible to use this threshold value for filtering out the irrelevant data coming from outside coverage area. By setting a threshold condition for a parameter value, you can define a global filter that will be applied to all subsequent Nemo Analyze operations (apart from Crystal Reports report templates). For the purposes of this use case, all data with Received Signal Code Power (RSCP) of -100 or higher will be considered measurement data from coverage area. The global filter created based on this condition will exclude all data with RSCP values lower than -100 from all subsequent Nemo Analyze operations. In other words, all Nemo Analyze operations will be filtered based on a secondary parameter, RSCP best active set. Filtering by secondary parameter enables the filtering of a primary parameter data set based on a selected secondary one. The resulting data set will contain only those values from the primary data set that coincide with the values in the secondary one. All parts of the primary data set that do not contain RSCP value of -100 or higher will not be considered measurement data from coverage area and thus will be excluded from the processed data set. To define a global filter, select Utilities | Global Filters from the Ribbonbar.

The Global Filters dialog opens.

To add a new filter, click Edit. The Analyze Wizard – Filters dialog opens.

V IEW ING M E ASU R E M EN T D A T A

10 7

To add a filter, click Add. An empty filter line is added.

Select from the Name drop-down menu. Click the … button in the Value column to browse for a secondary parameter. The Analyze Wizard – Measurement Parameters dialog opens. Select the parameter RSCP best active set and click Next.

10 8

Another Analyze Wizard – Filters dialog opens.

V IEW ING M E ASU R E M EN T D A T A

10 9

To add a filter, click Add. An empty filter line is added. Select the parameter Received signal code power from the Name drop-down menu. Next, select the operator >= (i.e. greater or equal) from the operator drop-down menu. Finally, enter the value -100 in the Value field.

Click Finish. This returns you to the first Analyze Wizard – Filters dialog.

Click Finish.

11 0

The Active global filters field of the Global Filters dialog now displays the defined filter.

All subsequent operations performed with Nemo Analyze during this session will be filtered based on the set threshold condition. To save the filter for use also during subsequent Nemo Analyze sessions, click Save. The Save Filter dialog opens.

Click OK. The Saved global filter sets field now displays the saved filter.

V IEW ING M E ASU R E M EN T D A T A

11 1

To activate a saved filter set, select a saved filter set in the Saved global filter sets and click the Set Active button. To remove a global filter, select the filter in the Saved global filter sets field and click Delete.

It is also possible to set a particular cell as filter by right-clicking on map on top of base station sector and selection Create Global Filter From Cell ID... From then on, all workbooks and queries will be limited in the way that results are returned only from those points where the cell in question has been serving.

11 2

D A TA V IEW S

11 3

FILTERING DATA AND CREATING CUSTOM KPIS Custom KPIs can be created either by correlating parameters using the Query Manager or, to create more complex KPIs, by using the KPI Workbench (see p. 358). With the correlate parameters functionality it is possible to create events based on complex search criteria, create events showing problems and reasons for problems, and create a CSV table from the measurement data for export purposes. You can create new Correlate parameters KPIs in the Query manager. In the Ribbonbar, select Tools | Query manager | Add… | Correlate parameters. The created KPI will be added to the User-branch in the Parameters view in the Workspace. The correlate parameters functionality can also be used for creating a custom KPI by right-clicking on a device in the Workspace, and selecting Correlate Parameters, and Next. In this case the new KPI will not be saved. Right-click on a device in the Workspace, and select Correlate Parameters.

11 4

In the Correlate Parameters dialog, select the parameters that you want to correlate. You can add two or more parameters in the Selected view. There are three different Modes available: Show values when first parameter changes (left outer join), Show values when any of the parameters changes (outer join), and Show values when all parameters are valid (inner join). The Show values when first parameter changes (left outer join) mode creates an output row for every value of the first selected parameter. For other selected parameters, it gives the current, previous, or next value from the time stamp of the first parameter. This mode can used to find all events of a certain type in the measurement data, and the values of other parameters at the time the event occurred. For example, it can be used to find all dropped calls (the first parameter), the last TX power, Best active Ec/N0, and Best active RSCP values prior to each drop.

After selecting the parameters to be correlated, click Next. In this example you can find six different parameters in the Selected view, Call dropped, Percentage of “DL power up” commands, Percentage of “UL power up” commands, Ec/N0 best active set, and RSCP best active set.

D A TA V IEW S

11 5

Select the data view in which the data will be displayed, for example, a grid, and click Finish. The correlation data is opened in the selected data view.

The Show values when any of the parameters changes (outer join) mode creates an output row when any of the selected parameters changes. This mode can also be used when exporting data to Excel. In the example below, there are three parameters in the Selected view, RX level full, Ec/N0 best active set, and BLER. Click Next. The correlation data is opened in the selected data view.

11 6

As you can see, there are no values for RX level full and RAC in rows 4600-4616, and no values for Ec/N0 and BLER in rows 4614-4620.

The Show values when all parameters are valid (inner join) mode creates an output row when any of the selected parameters changes, and all the parameters are valid. This mode can be used when generating input for scatter graph, or when creating events based on custom search criteria. In the example below you can see a custom KPI: all rows where Ec/N0 < -7, BLER, and RSCP < -79 are shown.

D A TA V IEW S

11 7

11 8

DRILL-DOWN The Troubleshooting toolkit with drill-down is an optional component of Nemo Analyze. When a query has been performed with one of the Troubleshooting parameters from the Parameters view, it is possible to drill down into further event detail from the data view created by the query. With pie charts, you can do this by double-clicking a sector of the pie chart or a sector color in the pie chart legend. As each sector represents a problem cause, double-clicking a sector will open a grid with a list of all problem events caused by that particular problem cause. Each drill-down from the same chart will open a new tab in the same window. These tabs are displayed on the left side of the window with the colors of the corresponding sectors.

Open tabs representing results of drill-downs from different sectors of this pie chart. The colors correspond with the pie chart sector colors.

For example, green color represents RACH Failure, unknown reason on the pie chart above. To drill down to the details of events where a RACH failure has occurred because of an unknown reason, double-click either the green sector on the chart or the text Failure, unknown reason on the chart legend.

DAT A V IEW S

11 9

This opens a grid where all failure events in the measurement data resulting from an unknown reason are gathered (see below). This grid will be represented by a green tab on the left of the window in the pie chart view.

Click blue arrow to return to the pie chart.

Click green tab to return to this grid from the pie chart.

Before drilling down into a single row of a grid, you can set a time range for log entries before and after the selected event that are to be included in the drill-down. To set a time range, select Utilities | Drill-down from the Ribbonbar and enter the time range in seconds in the Before and After fields.

12 0

To drill down into a single row of a grid, either double-click or right-click on the selected row. Doubleclick will perform the drill-down if there are default drill-down parameters that are compatible with the measurement data on that particular row. If however there are not, you can either right-click on the selected row and select Drill-Down | Pick Parameter to drill down into the data on that row with other parameters, or open the row in a separate workbook by right-clicking on the row and selecting DrillDown | [workbook] (e.g. UMTS | UMTS Troubleshooting.)

Each drill-down opens the selected time range of measurement data with the selected new parameters in new tabs on the second tab row.

Drill-down tab The selected time range

DAT A V IEW S

12 1

Drilling Down from Map Data View The Troubleshooting toolkit with drill-down is an optional component of Nemo Analyze. When a parameter is on opened on map, it is possible to drill down into further event detail by opening a workbook on a selected portion of the measurement route. To drill-down from map data view, select the route portion you want to see details on by left-clicking the position icon signifying the location of the measurement device in relation to the route.

To further define the extent or the time range of the target portion of the route (i.e. a time range surrounding the time stamp of the current location of the position icon), select Utilities | Drill-down from the Ribbonbar, and enter the time range in seconds in the Before and After fields.

Right-click on the position icon, and select Drill-Down | [select system] | [Select workbook] from the popup menu.

12 2

The drill-down workbook is added as a tab to the original map data view.

To return to the map view, click the

tab in the upper left corner of the workbook.

DAT A V IEW S

12 3

Drilling Down from Troubleshooting Parameters in Map Data View The Troubleshooting toolkit with drill-down is an optional component of Nemo Analyze. When a troubleshooting parameter is on opened on map, it is possible to drill down into further event detail on a failure event displayed on map. To open a troubleshooting query on map, select a measurement file in the Folder Contents section and a relevant failure-related troubleshooting parameter from under the Troubleshooting item in the Parameters view. ♦ Note that the Parameters view contains also versions of the failure parameters that do not belong to the Troubleshooting package and thus are not compatible with drill-down To search for failure-related troubleshooting parameters from the Parameters view, type the word drop or failure in the filter field above the Parameters view.

12 4

Right-click on the relevant failure parameter and select Open In | Map from the popup menu. The results of the troubleshooting query are opened on map.

To drill down to a failure event, double click on the event symbol. The drill-down workbook added as a tab to the original map data view.

To return to the map view, click the

tab in the upper left corner of the workbook.

DAT A V IEW S

12 5

DATA VIEWS In this chapter are explained the various types of data views available in Nemo Analyze. In Nemo Analyze synchronization is used to keep the different data views in sync. When you click any view containing data, all the other views jump to the same point of time. Nemo Analyze also offers the convenience of the so-called drag & drop function. You can easily drag measurements or measurement parameters from the Workspace in the various data views. Thus, one data view can contain many different parameters from one or more measurement files. When you right-click on any of the data views, a popup menu will open up. The menu offers access to all functions and tools related to that data view. The contents of the menu vary depending on the data view type (graph, grid, map, etc.) but some of the items are common to all data views.

GRAPHS Graph Tools Menu ♦ Note: The Graph menu is displayed as part of the Ribbonbar only when a graph is open and in current use in Nemo Analyze. When you select another workbook or window, the Graph menu is closed automatically.

Reset empties the data view. All the data and layout settings are removed. Properties enables you to edit the graph layout. Side panel enables you to hide and display the side panel on the right-hand side of the grid. For more information, see Side Panel on page 132. Graph type enables you to change the type of a graph. Scroll enables you to change the mouse cursor to an arrow and scroll the view. The same function is available in the graph side panel. Zoom enables you to zoom the view. Hold down the left mouse button and drag to the right to zoom in. Hold down the left mouse button and drag to the left to zoom out. The same function is available in the graph side panel. Zoom In and Zoom Out enable you to zoom in and out one step at a time. The same functions are available in the graph side panel. You can also zoom in and out on the view with the mouse wheel.

12 6

Pick parameter enables you to add more data in data views. Mode

defines how the different layers in the graph are displayed (single/stacked/automatic).

3D mode enables you to switch the 3D mode on/off. The same function is available in the graph toolbar. Note that this function is available for bar graphs only. Add task enables you to add a new task. Bin data enables you to define data bins for scatter graphs and color grids. In the Bin Data dialog, select the Enabled option to activate data binning. When data binning is activated, the scatter graph or color grid is divided into four data bins (defined by bin limits). For each data bin, the percentage of the samples out of all samples, or the number of samples in that bin is displayed. Reference Lines | Horizontal and Reference Lines | Vertical enable you to add a vertical or horizontal reference line in the graph. You can move the line by dragging with your mouse. The same functions are available in the graph side panel.

DAT A V IEW S

12 7

Graph Popup Menu From the graph popup menu you will find all graph-related tools and functions. Right-click on a graph to access the menu.

Change Graph Type With the Change Graph Type function you can change the type of a graph. In the Choose Graph Type dialog, select the graph type, line, bar, scatter, pie, color grid, or surface graph, from the selection and the graph is opened

Reset With the Reset function you can empty the data view. All the data and layout settings are removed.

Query With the Query tool you can change the data displayed in the data view. With the Cut, Copy, and Paste functions you can copy or cut an existing query from one data view and paste it to another. This is especially useful if you want to open another view with the same data but with a different graph type or copy data from a graph to a grid. The copied queries are available in the Query Clipboard.

12 8

Pick Parameter With the Pick Parameter tool you can add more data in data views. In graphs a new layer is added, in grids the new parameter is added in the same grid, and in maps a new route is added. Right-click on the graph and select Pick Parameter. In the Pick Parameter dialog, select the measurement file that you are currently viewing and then select the new parameter that will be displayed in the data view. Click OK to add the new parameter.

In the Filter field you can type the name of a specific parameter so that only that parameter will be shown. For example, in the picture below, you can see all the parameters starting with ´Missing Neighbor. This is useful for locating a parameter when the list is long.

DAT A V IEW S

12 9

Add Function With the Add Function feature you can add some averaging functions in graphs.

Color defines the color of the function line. Source defines the parameter for which the averaging function is performed. Function defines what kind of averaging function is added. •

Average calculates the average value for the selected parameter.



Exponential moving average calculates the average value using the following formula: 2 / Period value + 1. Period refers to the number of samples included in the calculation.



High calculates the highest value for the selected parameter.



Low calculates the lowest value for the selected parameter.



Median calculates the median value for the selected parameter.



Mode calculates the mode value, i.e., the most common value for the selected parameter.



Moving average calculates the moving average value for the defined period (number of samples).



Trend calculates the trend line for the selected parameter.

Period refers to the number of samples included in the calculation. Line width defines the line width of the function layer.

Add Reference Line With the Add Reference Line tools you can add a vertical or horizontal reference line in the graph. You can move the line by dragging with your mouse. The same functions are available in the graph side panel.

13 0

Tool Under the Tool item you will find two graph viewing tools: scroll and zoom. With the Scroll tool you can change the mouse cursor to an arrow and scroll the view. The same function is available in the graph side panel . With the Zoom tool you can zoom the view. Hold down the left mouse button and drag to the right to zoom in. Hold down the left mouse button and drag to the left to zoom out. The same function is available in the graph side panel . With the Zoom In and Zoom Out toolbar buttons you can zoom in and out one step at a time. The same functions are available in the graph side panel. You can also zoom in and out on the view with the mouse wheel.

Mode When you have several layers open in a graph, you can change the layout of the page. Mode defines how the different layers in the graph are displayed. In Single mode, the layers are displayed overlapping each other as in the example below. The scale is displayed only for the active layer (highlighted with light-blue color in the Layers panel on the right).

In Stacked mode, the layers are displayed one layer after another and the scale is displayed for each parameter. You can change the order of layers in graph by right-clicking a layer in the Layers panel on the right and selecting Move Up or Move Down.

DAT A V IEW S

13 1

In Automatic mode, all layers that have the same Y-axis are automatically stacked into one graph (similar to “Single” mode). Layers that have different scale are shown in “Stacked” mode.

13 2

Side Panel With the Side Panel option you can hide and display the side panel on the right-hand side of the graph.

DAT A V IEW S

13 3

The Tools panel contains tools for viewing graphs. See page 130 for more information on the zooming tools and page 129 on the reference line tools.

With the Bin data tool you can define data bins for scatter graphs and color grids. In the Bin Data dialog, select the Enabled option to activate data binning. When data binning is activated, the scatter graph or color grid is divided into four data bins (defined by bin limits). For each data bin, the percentage of the samples out of all samples, or the number of samples in that bin is displayed.

Bin limits defines the horizontal and vertical limits for the data bins. Output format defines if the data binning values are shown in percentages or the number of samples. In the example below, the horizontal bin limit is 50, vertical limit -12, and the output format is percentage. The percentage values are displayed in the corners.

13 4

The Layers panel displays the layers that are currently open in the view. When you add more parameters in the view, a new layer is created for each parameter. You can remove layers from the view by clicking the Close button (x) and hide layers by clearing the respective option. The Numerical Data panel displays selected information from the measurement.

DAT A V IEW S

13 5

Line Graph Filled In line graphs, select the Filled option in the graph popup menu to show the graph as "filled".

3D Mode With the 3D Mode function you can switch the 3D mode on/off. The same function is available in the graph toolbar . Note that this function is available for bar graphs only.

13 6

Group Values Group Values enables you to group bars in bar graphs by parameter rather than by x axis values. To enable/disable Group Values, right-click on the bar graph and select Group Values from the popup menu. If Group Values is disabled, bars are sorted based on their x axis values. In the screenshot below, the bars are sorted based on their x axis values, i.e. Scrambling Code/Channel Number.

If Group Values is enabled, bars are sorted by parameter. In the screenshot below, the bars are sorted based on parameter, i.e. Ec/N0 Active Set and Ec/N0 Monitored Set).

DAT A V IEW S

13 7

Graph Properties In the Graph Properties dialog you can edit the graph layout. These settings are the same for all graph types. Mode defines if the layers are stacked, in single, or in automatic mode. Show side panel hides/displays the data panel on the right-hand side of the data view. Group values defines the grouping of values belonging to the same layer when multiple layers are displayed in the same chart. Applicable for bar graph only. Axes defines the scales for the left and right x axis. 3D defines the 3D view of the chart.Orthogonal and Angle define the angle of the 3D chart.

Coloring mode defines the coloring mode for the graph. Transparency defines the transparency of the graph. Chart color defines the color for the chart. Margin color defines the color for the margin. Gradient enables gradient coloring of the chart background and margin areas.

13 8

The Layers tab displays a list of all layers open in the graph. You can add and remove layers. Double-click a layer name or select the layer from the list and click Modify to access the Layer Properties dialog.

DAT A V IEW S

13 9

Layer Properties Right-click on a graph and select Properties. In the Graph Properties dialog, go to the Layers tab and double-click the layer name. The Layer tab in the Layer Properties dialog is common for all graph types but some of the options might be missing for some graph types. If there are graph type specific settings, they are found in the second tab. Note that all graph types do not have any special settings so there might be only one tab in the Layer Properties dialog. The graph type specific settings are explained in the following chapters.

Name defines the layer name. The name is displayed at the bottom of the data view. Show marks displays the parameter values in small labels on the graph. Title defines a name for the axis. When the Scale automatically to values option is selected, the software checks what values exist for the parameter in the file and scales the axes accordingly. Alternatively you can define the Top and Bottom scales manually.

Parameter tab allows you to add filters, and modify existing filters and user-definable attributes. For instance, with N parameters (e.g. Ec/N0 Nth best), an N-based filter such as N = 1 is automatically set. To display the 2nd best cell instead of the default 1st best, change the filter value from N = 1 to N = 2.

14 0

Default color defines the default color for the line or bar. Color set colors the line/bar according to the selected color set.

Layer Properties for Line Graphs

Line width defines the line thickness in pixels. When the Hold value constant until next option is selected, the line is drawn at the same level until the value changes. See examples below. When the Show value points option is selected, value points are shown in the line graph.

In the example below, the Hold value constant until next option is not selected.

In the example below, the Hold value constant until next option is selected.

DAT A V IEW S

14 1

14 2

Layer Properties for Bar Graphs Style defines the shape (rectangle, ellipse, diamond, etc.) in which bars are displayed in the graph. Sorting defines the order in which the bars are displayed in the graph. The bars can be sorted in ascending or descending order based on the values on the X or Y axis.

Layer Properties for Scatter Graphs

Mode defines which results are displayed in the scatter graph. Style defines the scatter shape.

DAT A V IEW S

14 3

Use Case 5.: Multiple Graph Layers You can have as many layers as you like open in a graph. The example graph below has three layers open in stacked mode.

If you have many layers open, it may come in handy to resize the page to fit even more layers in the graph. Right-click on the graph and select Page | Properties.

In the Page Properties dialog, go to the Page tab. With the Fixed Size setting you can define the size of the page.

14 4

If the Fit to window option is selected, all the layers are displayed in the visible area of the page. This means that when a new layer is added, the space for each layer gets smaller. With the Fixed size option you can define an exact size in pixels for the page. This will give more space for each layer. With the scroll bar you can scroll up and down the page to view all layers.

When you have two layers in single mode you can select to view the scale for both of them. Right-click on the graph and select Properties. In the Graph Properties dialog, go to the Graph tab. In the left and right Axes setting select the two layers.

DAT A V IEW S

14 5

In this graph the left axis displays scales for Ec/No best active set, and the right axis for RX level full.

14 6

Use Case 6.: Notification Icons in Graphs You can view notification icons in graphs to notify you of special measurement events. Right-click on a graph and select Pick Parameter. From the Pick Parameter dialog, select Notifications and markers and click OK.

From the Notifications Properties dialog, select the notifications that you want to view in the graph and click OK.

The notification icons are displayed in the graph.

DAT A V IEW S

14 7

14 8

Use Case 7.: Correlating Parameters Using Color Grids and Surface Graphs Color grid and surface graphs are graph types designed for correlating two parameters. For the purposes of this use case, we will describe correlating parameters in a color grid. However, all of this information is also applicable with surface graphs. In addition to the default parameter pairs (such as Rx quality sub vs. Rx level sub) that are suggested when you right-click on an empty color grid and select Pick parameter, you can also define your own parameter pairs. To do this, create a new color grid by selecting View | Add Workbook | Graph from the Ribbonbar and once the empty data view opens, right-click on it, select Change Graph Type from the popup menu and select Color grid from the available graphs. Alternatively, if you already have a graph open, you can right-click on it, select Change Graph Type from the popup menu and select Color grid.

DAT A V IEW S

14 9

Next, right-click on the empty color grid, select Correlate Parameters from the popup menu and a Correlate Parameters dialog opens.

Scope defines the measurement data included in the color grid. Color set defines the color set for the color grid. X Parameter page defines the properties of X parameter. Parameter defines the X parameter. With Filters, you can define additional filters for the parameter. Minimum defines the minimum value for the parameter (see using filters). Maximum defines the maximum value for the parameter. Steps defines the number of steps on the color grid scales. Y Parameter page (see X parameter) After defining all the relevant values in the Correlate Parameters dialog, click OK and a color grid is created.

15 0

DAT A V IEW S

15 1

GRIDS Grids can be used to display all sorts of data. The data is displayed in numerical format in userdefined columns. You can export grid data to MS Excel or to a text file. You can also use color sets to highlight certain data in the grid. The first three items in the grid popup menu, Reset, Query, and Pick Parameter, are the same as in the graph popup menu. See page 127 for more information on them. Play Audio Sample is displayed only with grids containing an audio quality sample file column.

Side Panel With the Side Panel option you can hide and display the side panel on the right-hand side of the grid.

With the Search function, you can perform searches in grid views for text and values. Boolean operators are supported. You can highlight, filter in, or filter out matches.

15 2

Type in the search string in the Find field, select the columns that will be included in the search, and define if the search results should have matching case. Select the Highlight matches option if you want the matching cells highlighted. When the Filter in option is selected, only the search matches will be visible. When the Filter out option is selected, the search matches will be hidden. With the Search decoded messages option, you can search for grid entries based on a value in the decoded entry data (displayed in the Information panel). In the example below, both Search decoded messages and Filter in options are selected. Thus, only the two grid rows containing the searched decoded information are displayed.

The Layers panel displays the layers that are currently open in the view. When you add more parameters in the view, a new layer is created for each parameter. You can remove layers from the view by clicking the Close button (x).

DAT A V IEW S

15 3

The Information panel displays the selected message in decoded format. If you want to view the decoded data in a separate view, double-click the message or right-click on the message and select Row Details.

15 4

Row Details With the Row Details function you can decode grid data. The decoded data is opened in an Info View. You can also use double-click to decode grid data.

Export Data to With the Export Data to function you can export grid data to MS Excel, text file, MapInfo Tab file, and Google KML-File. When you export data to a MapInfo Tab or Google KML-file, you can then open the file as a route on a map. Select the appropriate option, and the exported data is saved on a file. Below is an example of exported data in an Excel sheet.

If you want to export multiple parameters so that each parameter is in its own column in an Excel sheet, first correlate the parameters and view the results in a grid. Then export the data. Note that only visible data is exported. In the Grid Properties dialog, you can select the visible parameters, e.g., latitude and longitude. Additionally, you can copy and paste any query from any control into a grid control where it can be exported. Right-click on a control and select Query | Copy. Then go to the grid, right-click on the grid and select Query | Paste.

DAT A V IEW S

15 5

Grid Properties In the Grid Properties dialog you can make various settings to the grid layout and select a color set.

From the Visible columns list, you can select the columns to be displayed. To change the order of columns, select the column you want to move and use the arrow buttons on the right to move it.

Add adds a parameter to the grid. Delete removes a parameter from the grid.

15 6

To define a color set for a grid column, select the column name, click the button that appears, and select a color set for the grid column from the drop-down menu. For more information, see use case Use Case 8.: Color Sets in Grids

Show heading hides/displays the column titles at the top of the grid view. Vertical text in heading option turns the column headings vertically. Show row numbers hides/displays the row numbers at the beginning of each row. Show time intervals hides/displays also the time interval in the Time column on each row. Font defines the font, font style, and font size used in the grid.

DAT A V IEW S

15 7

Use Case 8.: Color Sets in Grids In addition to maps, you can use different color sets for different columns in grids to make the data presentation more visual. In grids the color sets work as bar graphs. This use case describes how to use a color set in a grid. Right-click on the grid and select Properties.

In the Properties dialog, select the Color Sets tab. Next, select the column you want to apply a color set to and click the

button.

Select the appropriate color sets for the columns from the drop-down menu and click OK.

15 8

In the example below, Scr. Code and Ec/N0 columns are colored with the appropriate color sets.

The selected columns display the selected color sets. The size and color of the bar in each cell correlates with the parameter value.

DAT A V IEW S

15 9

Alternatively you can select the Color whole cell option in the Color Sets tab of the Grid Properties dialog. Using this setting, the whole cell will be colored and only the color of the cell will indicate the value.

16 0

Use Case 9.: Play Audio Sample Nemo audio quality measurement files include a sample of received audio quality. This makes it possible to compare the audio quality of the received sample with that of the original sent sample. To play the audio sample, select an audio quality measurement from the measurements and the parameter Audio Sample File Name UL from the Parameters view. Right-click on the parameter and select Open In | Grid from the popup menu.

The measurement opens on a grid. Right-click on the row with the audio sample you want to hear and select Play Audio Sample from the popup menu.

DAT A V IEW S

16 1

16 2

Use Case 10.: Using L3 and RRC Message Search Parameters To search values of particular type from decoded L3 and RRC signaling messages, first select a measurement file in Workspace | Measurements | Folder Contents. Then, select a search parameter depending on your need: • Text search parameters (e.g. L3 signaling text search) are used for searching text strings • value search parameters (e.g. L3 signaling value search) are used for searching numeric values

Double-click on the selected search parameter.

DAT A V IEW S

16 3

The Analyze Wizard – Filters dialog opens.

Search string defines the string after which the searched values can be found in the searched data set. For instance, as LAC values are always in the format LAC: , the value search will employ LAC as the search string. Note that colon (:) character is not required in the search string. The search results will thus contain the numeric values that immediately follow the string LAC. If there are multiple matches for the search string inside a message, the first match is returned. Parameter name allows the user to define a name for the column that displays the searched values in the result data set (see below).

Q U ER I ES

16 4

MAPS Nemo Analyze incorporates the following mapping methods; MapInfo-format (.tab) maps based on the MapX engine, KML format-based live maps, Nokia Maps with Street, Satellite and Terrain maps (part of the Nemo Analyze Professional package), WMS map sources, WMTS map sources, and ArcGIS MapServer sources. Maps can be used to display the measurement route, base station icons, and notification icons. The route can be colored based on parameter values.

Viewing on Live Map Nemo Analyze allows you to view measurements on KML format-based live maps, Google Maps, Google Earth, Nokia maps, and OpenStreetMaps. An internet connection is required for viewing measurements on live maps. The map tiles are retrieved as needed when map is opened, zoomed, or panned. ♦ To ensure the live map functionality to work appropriately, it is recommended to use Internet Explorer 8 or newer with Windows XP® Professional and Internet Explorer 9 with Windows Vista™/Windows® 7. It is also possible to use some additional map services that are available with the Nemo Analyze setup package. The additional services, Web Map Service (WMS), Web Map Tile Service (WMTS), and ArcGIS map sources, make it possible to utilize more than 100 high-resolution aerial image and terrain elevation data sources, including US Geological Service and several other GIS servers worldwide.

Import the settings configurations for these map services by selecting in Nemo Analyze Settings | Nemo Tools | Nemo Analyze | Map Configurations. Select a map service from the list and click Open. Finally, select OK in the Import Settings dialog. The imported map services can be found from the Maps tab of the Workspace.

DAT A V IEW S

16 5

Live maps can be used the same way as regular MapInfo maps. Data and base stations can be plotted on the map and data can be dragged to the map as in MapInfo maps. When playing back measurement data, the cursor is seen on the map and lines are drawn to the connected base stations. Live maps can be found from the Maps tab of the Workspace.

Maps can be used to display the measurement route, base station icons, and notification icons. The route can be colored based on parameter values. OpenStreetMap is included in the Nemo Analyze Professional feature package. OpenStreetMap is a free map resource available globally. The maps are updated with the same open source principle as, for example, Wikipedia. At the moment, the level of details in OpenStreetMap is similar to Google Maps with Street View for the most part. The following figure illustrates OpenStreetmap data overlay:

Google Maps is an optional feature. It incorporates a street view, a satellite view, a hybrid map of satellite and streets, and a physical map with terrain elevation illustrated.

Q U ER I ES

16 6

Google Hybrid map with route overlay:

DAT A V IEW S

16 7

Google Street View If a problem has occurred during data gathering, it is possible to check measurement route spots with the help of Google Street View. Google Street View enables exploring the route spots through 360degree street-level imagery. Select Maps page from the Workspace and double-click Google Streets to open the Google Street View. After this, drag and drop a measurement file from Workspace | Measurements onto the map. Right-click on the route and select Show Street View On Route Point from the popup menu.

Q U ER I ES

16 8

The view is split into two parts as illustrated below:

Hide Google Street View by right-clicking on the route and selecting Hide Street View from the pop up menu. With Google maps you are also able to view elevation on visible part of the active route. Right-click on active route, and select Show Route Elevation from the pop up menu.

DAT A V IEW S

16 9

Google Earth Google Earth enables ground-level navigation with 3D models of buildings on the route spot. Google Earth has three 'modes': normal sky view, Street View (pegman) and ground-level view. Select Maps page from the Workspace and double-click Google Earth. After this, drag and drop a measurement file from Workspace | Measurements onto the map to show the route on the map in sky view. To see view street view of the route, drag the pegman to the route. To toggle between Street View and a ground-level view that allows for intuitive navigation on the ground level, click the icons of the top of the image.

Map Tools Menu ♦ Note: The Map menu is displayed as part of the Ribbonbar only when a map is open and in current use in Nemo Analyze. When you select another workbook or window, the Map menu is closed automatically.

Properties enables you to customize the map view. Side panel

enables you to hide and display the side panel on the right-hand side of the grid.

Save geoset enables the saving of customized settings as a MapInfo Geoset file (.gst).

Q U ER I ES

17 0

Organize layers enables you to change the order of layers on the map Properties enables you to customize projection and other MapX-specific settings. Arrow Pan

enables you to select items on the map view. enables you to scroll the map.

Zoom in and Zoom out views with the mouse wheel. Center

enable you to zoom the view. You can also zoom in and out on the

enables you to center the map based on a selected point on the map.

Measure distance

enables you to measure the distance between two points selected on map.

Offset route enables you to move the measurement route to another location. Select the route you want to move and then click on the new location. Highlight value enables you to highlight selected values on map route. First open the Color tab of the Route Properties dialog and set Default Color as Mode and select a parameter from the Parameter drop-down menu. Then click on the route with the Highlight value tool and the Highlight Value dialog will open. The dialog displays all the values of the selected event type. From the list, pick the value that you would like to be highlighted and select a color for that value. Click OK and the value is colored in the selected value. View entire map

enables you to zoom out quickly.

Draw polygon enables you to create a polygon area by clicking on the map. The polygon is closed by clicking on the start point of the polygon. Generate colorset generates a colorset. Export to KML enables you to export a measurement route from Nemo Analyze map to Google Earth in KML format. Zoom to layers extends zoom to layers. Folder from area creates a folder from an area. Polygon region enables you to create polygon area by clicking on the map. Polygon is closed by double-clicking the end point of the polygon. Area binning enables you to define an area on a map which you can run statistics on in the form of bins. The results are displayed on the map as a new semi-transparent layer. Delta plotting enables you to compare the parameter values of two measurement groups from a same route by defining an area on a map (e.g. a portion of the measurement route). For more information on Delta Plotting, see the topic Use Case 14.: Comparing Two Groups of Measurements from the Same Route on Map. Auto centering enables you to force the map to be always centered on the current location. Route names, when activated, displays route names on the map. Current position option displays the current position and direction on the map.

DAT A V IEW S

17 1

Highlight active route option displays the currently selected route highlighted so it is easy to see on the map. Optimized drawing improves the performance of the route drawing on the map. However, on rare occasions with some projections it may result in skewed route plot. In such case, deselect this option. Scale bar option displays a distance scale bar on the map. Select map: The drop-down menu in Map | Maps enables you to change the map type of the active map workbook.

Map Popup Menu The first items in the map popup menu, Reset, Query, and Pick Parameter are the same as in the graph popup menu.

Add Under the Add item you will find options you can add on a map view. With the Add Map Layer function you can add a map layer (.tab or .gst) in the same map view. With the Add Measurement function you can add another measurement file on the same map. Select the file from the Add Measurement dialog and click OK.

Q U ER I ES

17 2

The new route will be displayed in addition to the existing one(s). With the Add Frame and Add Comment functions you can add frames and comments on the map view. A frame is a resizable window that can contain any of the available data view types. For example, you can open the color legend in a frame.

A comment is a fixed-size window that is attached to certain coordinates on a map. If you scroll the map, the comment window will move as well. You can remove frames and comments by right-clicking on them and selecting Frame | Remove or Comment | Remove.

DAT A V IEW S

17 3

Find If you require a more detailed map from the same location, right-click on the route and select Find | Map at Route or right-click anywhere on the map and select Find Map at Position. ♦ Note that the Find feature only works with raster maps. The Map Search dialog will be opened with the matching maps. You can choose whether the new map is displayed in a new workbook (Open) or as a layer (Add Layer) on the same map. Nemo Analyze will search for the maps from the location you specified for maps in the Options dialog box (View | Tools | Options | Environment | Default Paths).

In the example below, the new map is pasted on top of the existing map as a new layer.

Q U ER I ES

17 4

Generate Color Set See Automatic Generation of Color Sets

Export to KML File To export a measurement route from Nemo Analyze map to Google Earth in KML format, in map data view, right-click on the map and select Export to KML file from the popup menu.

Alternatively, you can right-click on the route and select Export Data To | Google KML File from the popup menu.

The Save As dialog opens.

DAT A V IEW S

17 5

To save the route as a Google KML file, type in a file name in the File name field and click Save. To open a KML file with Google Earth, go to Google Earth and select File | Open from the Google Earth main menu. In the Open dialog, select a KML file and click Open. Google Earth displays the route complete with color sets, notification icons, etc.

In some cases, Google Earth may not be able to display the exported data in OpenGL mode. To switch to Direct X mode, select Tools | Options from the Google Earth main menu bar. The Google Earth Options dialog opens. Select Direct X in Graphics Mode section and click OK. To apply the changes, restart Google Earth.

Q U ER I ES

17 6

Side Panel - Map With the Side Panel option you can hide and display the side panel on the right-hand side of the map.

The Tools panel provides you with controls for manipulating the map view. The function of each tool is described below.

With the Arrow With the Pan

tool you can select items on the map view. tool you can scroll the map.

With the Zoom In and Zoom Out on the views with the mouse wheel. With the Center

tools you can zoom the view. You can also zoom in and out

tool you can center the map on the point where you click.

DAT A V IEW S

17 7

With the Area Binning tool you can define an area on a map which you can run statistics on in the form of bins. The results are displayed on the map as a new semi-transparent layer. With the Statistics From Polygon Area tool you can specify an area of any shape, and run statistics over that area. The results are displayed in the statistics data view. With the Delta Plotting tool you can and compare the parameter values of two measurement groups from a same route by defining an area on a map (e.g. a portion of the measurement route). For more information on Delta Plotting, see the topic Use Case 14.: Comparing Two Groups of Measurements from the Same Route on Map on p. 209. With the Distance

tool you can measure the distance between two points.

With the Offset tool you can move the measurement route to another location. Click on the route you want to move, and then on the new location. With the Highlight tool you can highlight selected values on the map route. First select a scheme in the Route Properties, Color dialog). Then click on the route and the Highlight Value dialog will be opened. The dialog displays all the values of the selected event type. From the list, pick the value that you would like to be highlighted and select a color for that value. Click OK and the value is colored in the selected value. With the View Entire Map

tool you can zoom out quickly.

With the Organize Layers more information on the tool.

tool you can change the order of layers on the map. See page 179 for

With the Draw Polygon tool you can create a polygon area by clicking on the map. The polygon is closed by clicking on the start point of the polygon. The BTS Filter drop-down menu allows you to select which BTS cells are displayed on the map.

Q U ER I ES

17 8

The Layers panel displays the layers that are currently open in the view. When you add more routes on the map, a new layer is created. You can remove layers from the view by clicking the Close button (x) and hide layers by clearing the respective option. Right-click on the layer titles in the layer browser to access a set of map-related tools.

With the Zoom To tool you can zoom to the selected route. This is useful if you have several measurements open on the same map. With the Move To Top tool you can move a selected layer to top. With the Find tool you can search another map that matches the measurement route. Note that the Find feature only works with raster maps. See page 173 for more information on the Find tool. With the View In Live Map tool you can view measurements in live maps. With the Export Data To tool enables you to export data to MapInfo Tab-file/Google KML-File. With the Show BTS Connections tool you can enable base station connections to be displayed on the map. With the Add Task tool you can add a new task. With the Remove tool you can remove the selected layer. With the Properties option you can open the Route Properties dialog (see page 181 for more information). The Active Layer panel displays the name of the active layer and information on BTS sites to which the test device is currently connected. The Color Legends panel displays the color sets in use.

DAT A V IEW S

17 9

Tool Under the Tool item you will find a selection of tools for viewing the map.

These same functions are available in the map side panel.

MapX Under the MapX item you will find tools related to MapX maps.

With the View Entire Map tool you can zoom out quickly. You can customize the map view using the MapX properties. With the Save Geoset function the customized settings can be saved in a MapInfo Geoset file (.gst) and loaded later on. With the Organize Layers tool you change the order of map layers. In the Layer Control dialog, change the order with the Up and Down buttons. Clear the Visible option if you want to hide a layer from the map.

Q U ER I ES

18 0

Properties will open the MapX Properties dialog.

In the Layers tab the table a list of the current layers is shown. The order on the list defines the order in which the layers are displayed on a map; for example, in this case the Route layer is on the top, BTS sites under that, and World map at the bottom. This utility is useful if you want to have a bigger map on the bottom (e.g., a map of Europe) and a more detailed map of a smaller area (e.g., of Helsinki) on top of that. To add layers on the map click Add. An Open dialog box is opened where you can choose the map you want to add as a layer. The map is added on the list and with the Up and Down you can change the map’s position on the list. By selecting and clearing the Visible option you can decide whether or not to display the layer on the map. To remove layers from the map, select the layer from the list and click the Remove button.

DAT A V IEW S

18 1

Map Properties The Properties item will open the Map Properties dialog. In the Map Properties dialog you can define how the BTS icons are displayed. You can also select and clear the Auto centering tool.

Auto centering option keeps the map focus always on the measurement vehicle. Show route names option displays route names on the map. Show current position option displays the current position and direction on the map. Highlight active route option displays the currently selected route highlighted so it is easy to see on the map. Show scale bar option displays a distance scale bar on the map. Select the Draw line to active base station option to draw line from the serving BTS to the test vehicle. Display BTS overlay on top of other layers option keeps BTS layers always on top of the route layers.

Q U ER I ES

18 2

Route Properties In the Route Properties dialog you can modify the appearance and settings of the measurement route on the map. Right-click on the route and select Properties. On the last five pages you have the option to apply the new settings to all routes visible on the map. Name defines the title of the route layer. Draw Mode defines how the route is drawn (line or symbol). See page 185 for more information. Hide long distance lines option hides unusually long lines which probably mean that there is a problem with the GPS connection. Pixel Offset values enable you to move the route on the map horizontally and vertically. Thickness defines the route thickness in pixels. You can define, for example, a thicker line to be drawn when the test device is in high band.

Select measurement events that will be displayed on the map as icons. Select the Print description option to view event descriptions (e.g., marker numbers) on the map. Select the Hide overlapping descriptions option to hide the description text if the texts overlap each other. Pixel offset values enable you to change the position of notification icons on map horizontally and vertically.

DAT A V IEW S

18 3

Mode defines if the route is colored using the default color or using valuebased coloring. If you select color rotation, the color of the route changes whenever the value of the selected parameter changes. Parameter defines the parameter used in the coloring. Color set defines the colors for parameter values. Filters displays the parameters used in the query.

Tooltip defines a set of "Tooltip parameters" that are shown in a tooltip when mouse is hovered over it. The parameters should be defined per system so that different set of parameter would be shown depending on the serving system (LTE/GSM/UMTS/etc.) at the location on the route.

Q U ER I ES

18 4

Parameter defines the parameter which will be displayed as numerical values along the measurement route. Font and Color define the text settings. Select the Hide overlapping values option to hide the values if the texts overlap each other.

BTS defines which lines are drawn to form a measurement route.

DAT A V IEW S

18 5

Draw Route as Symbols You can draw the route on a map as symbols. In the Route Properties dialog, select Symbol in the Draw Mode field and click the … button. In the Symbol Style dialog, define the appearance of the symbol and click OK.

Font defines the symbol font. Symbol defines the symbol used to draw the route. Color defines the symbol color. Rotation angle defines in which angle the symbol is drawn on the map. Background defines what kind of background is added for the symbol. Effects defines what kind of effects are applied to the symbol.

Q U ER I ES

18 6

Below is an example of a map route drawn with symbols.

DAT A V IEW S

18 7

BTS Files In the workspace you will find a page for Base Stations by clicking on the workspace panel.

icon on the bottom of the

Files displays all BTS files stored in the database. File contents displays the contents (i.e. all base stations and the antennas of each station) of the BTS file selected in Files. Site information displays details of the base station/antenna selected in File contents. If there are multiple versions of the same BTS file, i.e. from different dates, the correct file is automatically selected based on the time of the measurement session if the file has been named according the naming convention filename_YYYY-MM-DD.nbf where filename must be identical with all versions of the same BTS file. The date suffix changes with the date (YYYY stands for year, MM for month, and DD for day) of the BTS file. ♦ Note: Change the filename format to filename_YYYY-MM-DD.nbf before you load the file to the database.

Q U ER I ES

18 8

A BTS file needs to be activated in order for it to be used in saved workbooks and BTS ref queries. When opening a BTS file, a Set Active BTS File dialog opens. The user can activate a file by ticking a box next to the file.

♦ Note: You can add custom site information columns to the BTS file. These columns will be displayed as part of site information in the Nemo Analyze UI. If there are multiple versions and the file has not been named according to the naming convention above, the relevant BTS file version must be activated. If none of the files are activated (i.e. designated as relevant files), reliable results cannot be guaranteed. To modify active BTS settings of a file that has already been added to the database, open the BTS page of the Workspace by clicking the Active from the popup menu.

button, right-click on the relevant BTS file, and select

To display base stations as BTS icons on map, drag and drop a BTS file from Workspace | Base Stations | Files to a map. The green sectors represent the antenna directions.

DAT A V IEW S

18 9

Q U ER I ES

19 0

Double-click on a BTS icon to view more information on that base station.

To connect the measurement route to the BTS, right-click on the route and select Properties. Go to the BTS tab, select the BTS file, and click OK. If the route is not associated with a BTS file, the line to the active base station is not drawn.

If you have several BTS files open on the map, you can define which base stations are displayed. Right-click on the map and select Properties. Select the Draw line to active system base stations to draw only the BTS icons from the system, for example, GSM that the mobile is currently using.

DAT A V IEW S

19 1

To connect the measurement route to the BTS, right-click on the route and select Properties. Go to the BTS tab, click Modify and select the BTS file to connect to, and click OK. If the route is not associated with a BTS file, the line to the active base station is not drawn.

Q U ER I ES

19 2

BTS Properties Right-click on the BTS file layer in the side panel and select Properties.

In the BTS Properties dialog you can edit the appearance of the BTS icons.

Draw line to active base station, option enables the drawing of a line from the serving BTS to the test vehicle.

DAT A V IEW S

19 3

Icon size defines the size of the BTS icon in pixels. Fixed defines the fixed size of BTS icons in pixels. Dynamic, max size defines a maximum size for dynamic BTS icons (i.e. icons which change size based on zoom level). Show site names option hides and displays the site names. Draw frame hides and displays the outlines of BTS icons. Site transparency defines the transparency of the BTS icons.

Show cell information option, when selected, allows you to choose what information is shown for BTS cells. Select Add to define which parameters are shown. Hide cell texts on low zoom levels (performance optimization) option hides cell text when the map is zoomed out so that the map can be drawn faster and with less visual distractions. Use cell beam range from BTS file allows you to enable/disable the display of cell beam range based on cell beam range data in the BTS file.

Q U ER I ES

19 4

Additionally, use estimation from antenna height and tilt estimates the base station coverage area based on antenna height and tilt. Beam transparency defines the transparency of the beam range layer.

Default color defines the color of the BTS icon. Mode (parameter/custom) enables the user to choose whether to use BTS Parameter or custom query option in the base station coloring. Technology allows the user to define the parameter coloring depending on the technology that has been used. BTS parameter defines the parameter used in the coloring. Mode (parameter/custom) enables the user to choose whether to use BTS Parameter or custom query option in the base station coloring. Custom query enables the user to select a custom query which defines how the coloring is done. Color set defines the colors for parameter values. Beam color defines the color that is used to draw a beam of a base station.

DAT A V IEW S

19 5

The Highlights page displays options that can be used to select colors used to display highlighted cells on the map. To apply the highlight colors, right-click on a cell on the map and select Highlight neighboring cells or Highlight sectors…

The Sites page displays a list of all sites and their cells in the BTS file.

Q U ER I ES

19 6

Use Case 11.: Adding Map Layers and Saving Layer Combinations as Geosets To add more map layers to the map view, drag and drop a .TAB file from the Workspace | Maps | Loaded view to an open map view.

For organizing map layers, see MapX on page 179. Once you have added the layers you need to the map, you can save the entire layer combination as a Geoset to enable direct access to the map in the future. To save the combination as a single Geoset, right-click on map view and select MapX | Save Geoset from the popup menu.

DAT A V IEW S

19 7

The Save As dialog opens.

Enter a name for the Geoset file and click Save. The Geoset Name dialog opens.

Enter a name for the Geoset and click OK. The entire combination of map layers can now be loaded into the database and opened as a single map.

Q U ER I ES

19 8

Use Case 12.: Coloring Routes Based on BTS Coverage This use case describes a situation where the user needs to view the coverage of a single base station on a map. It is assumed that there are measurement files with coordinates, BTS files, and corresponding maps in the database.

Step 1: Open a Measurement and a BTS file on a Map Open a map file and drag and drop measurements on it. Do not open any parameters. Next, drag and drop BTS files on the map and associate them with the route(s). .

Step 2: Color Routes Based on BTS Coverage To color route(s) based on base station coverage, right-click a base station and select Color Layers Based On Scrambling Code [number] from the popup menu.

The route will be colored based on the Ec/N0 or RSCP value of the selected base station.

To perform area binning on a selected part of the route, proceed to Use Case 13.: Performing Area Binning on page 199.

DAT A V IEW S

19 9

Use Case 13.: Performing Area Binning Step 1: Select Bin Area Click Area Binning icon on the Tools panel and select an area from the map. In the screenshot below, you can see the area selection surrounded by a thin dotted line.

Step 2: Select Measurement File(s) Selecting an area opens the Analyze Wizard – Select Measurement dialog below. In this dialog, you can add measurements you want to perform the area binning on. The measurement route on the map is included in the selected measurements by default. Folder defines the measurement folder whose contents are displayed in the field below. Using the Filter field, you can search for measurements. The Selected measurements field displays all the measurements that have been selected for area binning. With the button, you can select measurements With the button, you can clear measurements

After you have selected the measurements you want to perform the area binning on, click Next. This opens the Analyze Wizard – Measurement parameters dialog. If you are performing an area binning for a single base station (see

Q U ER I ES

20 0

Use Case 11.: Adding Map Layers and Saving Layer Combinations as Geosets To add more map layers to the map view, drag and drop a .TAB file from the Workspace | Maps | Loaded view to an open map view.

For organizing map layers, see MapX on page 179. Once you have added the layers you need to the map, you can save the entire layer combination as a Geoset to enable direct access to the map in the future. To save the combination as a single Geoset, right-click on map view and select MapX | Save Geoset from the popup menu.

DAT A V IEW S

20 1

The Save As dialog opens.

Enter a name for the Geoset file and click Save. The Geoset Name dialog opens.

Enter a name for the Geoset and click OK. The entire combination of map layers can now be loaded into the database and opened as a single map. Use Case 12.: Coloring Routes Based on BTS Coverage on page 196), type ‘selected’ in the filter field (as only selected scrambling code and selected channel parameters are relevant for this type of area binning) and select only selected scrambling code or selected channel parameters. Otherwise, select the relevant parameter and click Next.

Q U ER I ES

20 2

This opens the Analyze Wizard – Filters dialog. If you are performing an area binning for a single base station (see Use Case 11.: Adding Map Layers and Saving Layer Combinations as Geosets To add more map layers to the map view, drag and drop a .TAB file from the Workspace | Maps | Loaded view to an open map view.

For organizing map layers, see MapX on page 179. Once you have added the layers you need to the map, you can save the entire layer combination as a Geoset to enable direct access to the map in the future. To save the combination as a single Geoset, right-click on map view and select MapX | Save Geoset from the popup menu.

DAT A V IEW S

20 3

The Save As dialog opens.

Enter a name for the Geoset file and click Save. The Geoset Name dialog opens.

Enter a name for the Geoset and click OK. The entire combination of map layers can now be loaded into the database and opened as a single map.

Q U ER I ES

20 4

Use Case 12.: Coloring Routes Based on BTS Coverage on page 196), select a scrambling code or channel number value from the Value drop-down menu and click Finish. Otherwise, select the relevant filters and click Finish.

If you are performing an area binning for a single base station (see Use Case 11.: Adding Map Layers and Saving Layer Combinations as Geosets To add more map layers to the map view, drag and drop a .TAB file from the Workspace | Maps | Loaded view to an open map view.

For organizing map layers, see MapX on page 179. Once you have added the layers you need to the map, you can save the entire layer combination as a Geoset to enable direct access to the map in the future. To save the combination as a single Geoset, right-click on map view and select MapX | Save Geoset from the popup menu.

DAT A V IEW S

20 5

The Save As dialog opens.

Enter a name for the Geoset file and click Save. The Geoset Name dialog opens.

Enter a name for the Geoset and click OK. The entire combination of map layers can now be loaded into the database and opened as a single map.

Q U ER I ES

20 6

Use Case 12.: Coloring Routes Based on BTS Coverage on page 196), clicking Finish opens another Analyze Wizard – Filters dialog. Again, select the scrambling code or channel number value from the Value drop-down menu and click Finish.

The area binning statistics are by default weighted by time. Although area binning as an operation is location-based, each sample has its unique time and distance weights that can be used in calculating time and distance averages per bin. If you want to weight the results by distance, you must have Calculate statistics based on set to in Options | Environment | Statistics (see page 510). In this case, the Choose Statistics Type dialog will open after clicking Finish in the Analyze Wizard - Filters dialog above, allowing you to select Distance as statistics type. After selecting the statistics type, click OK.

DAT A V IEW S

20 7

The area binning results are displayed on the map as a new layer.

Step 3: Adjusting Bin Size To adjust bin size, right-click the area binning layer on the Layers panel and select Properties from the popup menu.

Q U ER I ES

20 8

In the Properties dialog, adjust bin size by changing the X steps and Y steps values. The higher the value is, the smaller the bin size. When the bin size has been adjusted, click OK, and the area binning layer is displayed with the new bin size.

Name refers to the name of the base parameter. X steps and Y steps define the bin size. Scrambling code refers to the scrambling code of the base station. Draw method defines whether the bins are displayed in Fixed size irrespective of the zoom level, or in Actual size. With the Statistic drop-down menu, you can select the aggregate displayed on the map: Minimum, Maximum, Sample count, Std. deviation and Variance. By default, average per bin is displayed. Color set defines the color set that is used. Transparency defines the transparency of the area binning layer.

Step 4: Exporting Area Binning Data To export area binning data to Excel, or to .txt or MapInfo .tab format, right-click the area binning layer on the Layers panel and select Export Data To | Excel or Export Data To | File from the popup menu. For more information on Export Data To function, see p. 154. For exporting area binning data to Google Earth in KML format, see Export to KML File.

DAT A V IEW S

20 9

Use Case 14.: Comparing Two Groups of Measurements from the Same Route on Map This use case describes a situation where the user needs to compare the parameter values of two groups of measurements from the same route. It is assumed that there are measurement files with coordinates and corresponding maps in the database.

Step 1: Open a Measurement File on a Map Open a map file and drag and drop measurements on it.

Step 2: Performing Delta Plotting on Map Delta plotting makes it possible to display the difference between two groups of measurements from the same route on map.

Click the Delta Plotting icon

on the Tools panel and select an area from the map.

In the screenshot below, you can see the area selection surrounded by a thin dotted line.

Selecting an area opens the Delta Plotting dialog.

Q U ER I ES

21 0

To select measurements for Measurement Group 1, click the Configure button and the Analyze Wizard – Select Measurement dialog opens. In this dialog, you can select the measurements you want to perform the delta plotting on. You can have one to many measurements in each measurement group. A measurement group average is calculated from all measurements within a Measurement Group. The difference value plotted on map represents the difference between the two measurement group averages.

Folder defines the measurement folder whose contents are displayed in the field below. Using the Filter field, you can search for measurements.

DAT A V IEW S

21 1

The Selected measurements field displays all the measurements that have been selected for the measurement group With the

button, you can select measurements

With the

button, you can clear measurements

Once you have selected the measurements you want to include in the Measurement Group 1, click Next. This opens the Analyze Wizard – Measurement parameters dialog. Select the parameter based on which you want to compare the two measurement groups and click Next. Note that you have to select the same parameter for both measurement groups.

The Analyze Wizard – Filters dialog opens.

Q U ER I ES

21 2

Filter options are optional. Define filter options if necessary and click Finish.

Repeat the steps above to define measurements for Measurement Group 2.

Once you have selected measurements for both measurement groups, click OK in the Delta Plotting dialog.

DAT A V IEW S

21 3

From the Choose Statistics Type dialog you can choose whether statistics are weighted by time (Time), or distance (Distance), or whether they are not weighted at all (Sample). Although delta plotting as an operation is by default distance-based, each sample has its unique time and distance weights that can be used in calculating time and distance averages per bin. In delta plotting this average per bin is calculated for bins of both routes separately. To find out the difference between the bin values of one route and the bin values of the other, a subtraction is performed between the bin values of the routes. Depending on the operation you are performing, select either Time, Distance, or Sample and click OK. The delta plotting results are displayed on the map as a new layer.

Q U ER I ES

21 4

Use Case 15.: Displaying Base Station Cell Beam Range on Map To display the cell beam range of an individual cell on map, select the relevant cell with a left-click.

The beam range of the selected cell is displayed on the map as a sector. If the BTS file you are using does not contain cell beam range data, you can set the range in BTS options. Select View | Options to define base station display settings.

The Options dialog opens. Select BTS | General.

DAT A V IEW S

21 5

BTS texts options allows you to define the size and style of BTS text. Display BTS overlay on top of other layers sets BTS layers to be displayed over all other layers. Default BTS filter allows you to set default BTS filter that will automatically turn the chosen filter on if there are such base stations in the BTS file. In the Map window there is a BTS filter field that enables the user to choose which base stations are shown:

For UMTS and LTE options you must set a Carrier number which defines which part of the BTS filter is chosen.

Q U ER I ES

21 6

Default enables you to define the default color for base stations when displayed in the map view. Default beam color enables you to define the default beam color. Default settings for BTS parameter, when selected, enables you to define default color sets for BTS parameters. BTS defines the parameter used in the coloring. Color set defines the colors for parameter values.

BTS Technology Based Settings enable you to choose the color and the size of the base station depending on which network´s base station it is, or based on the carrier number. When the Use technology based settings (overrides icon size settings) option is selected, you are able to open the Set Technology Setting view by clicking Add. By clicking the Icon color option, the size and the color of the base stations changes on the map. If this option is not selected, only the size of the base station changes.

DAT A V IEW S

21 7

To edit cell-specific properties, right-clicking on a base station icon cell, and select Properties from the popup menu.

The Current tab of the Properties dialog opens. To see descriptions of the

Beam range defines the cell beam range in meters.

Q U ER I ES

21 8

Draw line to active base station option enables the drawing of a line from the serving BTS to the test vehicle.

Icon size defines the size of the BTS icon in pixels. Fixed defines the fixed size of BTS icons in pixels. Dynamic, max size defines a maximum size for dynamic BTS icons (i.e. icons which change size based on zoom level). Show site names option hides and displays the site names. Draw frame hides and displays the outlines of BTS icons.

DAT A V IEW S

21 9

Site transparency defines the transparency of the BTS icons.

Show cell information option, when selected, allows you to choose what information is shown for BTS cells. Select Add to define which parameters are shown. Hide cell texts on low zoom levels (performance optimization) option hides partly or completely the cell texts when the map is zoomed out so that the map can be drawn faster and with less visual distractions. The level is adjustable with a slider. Zoom levels are specific to used maps. Use cell beam range from BTS file allows you to enable/disable the display of cell beam range based on cell beam range data in the BTS file. Additionally, use estimation from antenna height and tilt estimates the base station coverage area based on antenna height and tilt. Beam transparency defines the transparency of the beam range layer. Cell beam range can also be displayed by selecting a cell in Workspace | Base Stations | File Contents with a left-click.

Q U ER I ES

22 0

Use Case 16.: Synchronizing Base Station Map Overlay with Grid Rows Nemo Analyze allows the synchronization of grid data with base stations on map. To synchronize BTS map overlay with grid data, first open both a measurement file (p. 76) and a BTS file (p. 81) on map.

Next, split the data view vertically by right-clicking on the map and selecting Data View | Split | Vertically from the popup menu.

DAT A V IEW S

22 1

The data view is split into two sections.

To add a grid with BTS data to the empty section, drag and drop the BTS layer from the Layers panel on the right to the empty section.

Q U ER I ES

22 2

The Select Data View dialog opens.

Select Grid and click OK. A grid with BTS data is now displayed.

DAT A V IEW S

22 3

The map now zooms automatically to the cell selected in the grid.

Use Case 17.: Using BTS Reference Parameters Parameters view contains a set of parameters with the parameter name prefix BTS reference. These parameters display information on the current serving and neighboring cell(s) based on a BTS reference file (i.e. BTS file). BTS reference parameters can be used, for instance, to display the name of the serving cell in a workbook together with recorded metrics, or as an input data set in KPI workbench to enable the grouping of aggregates based on serving cell, etc. For the BTS reference parameters to work correctly, the relevant BTS reference file must be present in the database. A BTS file needs to be activated in order for it to be used in saved workbooks and BTS ref queries. When opening a BTS file, a Set Active BTS File dialog opens. The user can activate a file by ticking a box next to the file.

Q U ER I ES

22 4

If there are multiple versions of the same BTS file, e.g. from different dates, the relevant BTS file version must be activated. If none of the files are activated (i.e. designated as relevant files), reliable results cannot be guaranteed. To modify active BTS settings of a file that has already been added to the database, open the BTS page of the Workspace by clicking the button, right-click on the relevant BTS file, and select Activate from the popup menu.

DAT A V IEW S

22 5

Once the relevant BTS file has been activated, open the Measurements page of the Workspace by clicking the

button.

Select a measurement or a measurement folder, and type the word reference to the filter above the Parameters view to list BTS reference parameters.

To open a parameter in its default view, select a measurement in the Workspace and then doubleclick a parameter in the Parameters view. If you want to open the parameter in some other type of view, right-click on a parameter in the Parameters view and select the view type from the popup menu. To run statistics based on the parameter, select the parameter in the Parameters view and click the click on the button displayed at the bottom left corner of the Parameters view. This opens the Parameter Launchpad. For more information on Parameter Launchpad, see page 69.

Q U ER I ES

22 6

Use Case 18.: Displaying Base Station Connections on Map Based on Any Parameter Nemo Analyze allows base station connections to be displayed on map based on any parameter containing BTS connection data. This can be useful, for instance, in terms of finding and visualizing cells causing pilot pollution. To display base station connections from terminal to individual cells on map based on any parameter, select a measurement file from Folder Contents, right-click on a parameter (e.g. Pilot pollution) in the Parameters view, and select Open In | Map from the popup menu.

DAT A V IEW S

The measurement route is displayed on map.

Click the Base Stations button in Workspace.

22 7

Q U ER I ES

22 8

The Base Stations page opens.

Drag and drop a base station file from the Files field to the map. A dialog is displayed asking whether you would like to associate the open route with the BTS file.

Select Yes.

DAT A V IEW S

22 9

BTS overlay is displayed on map.

Right-click on the route layer displayed on the side panel and select Show BTS connections from the popup menu. The Route tab of the Route Properties dialog opens.

Select the BTS tab, clear the options Active/Serving Cells and Monitored/Neighbor Cells, select the [Parameter] BTS (e.g. Pilot Pollution BTS) option, and click OK.

Q U ER I ES

23 0

Base station connections are displayed on map based on the selected parameter (e.g. Pilot pollution).

DAT A V IEW S

23 1

SPREADSHEETS Nemo Analyze spreadsheets enable the processing of measurement data in spreadsheet format. As the basic functionality of Nemo Analyze spreadsheets is in line with the de facto standard followed by most spreadsheet applications on the market, this section will focus only on those features and usages that are specific to Nemo Analyze and to measurement data post-processing. Select View | Workbook | Spreadsheet Grid in the Ribbonbar to open an empty spreadsheet. You can drag and drop parameters on the spreadsheet from the Parameters view. Nemo Analyze will display a green icon if spreadsheet is a suitable data view for the parameter, and a red icon the data view is unsuitable.

The query is opened on the spreadsheet.

if

Q U ER I ES

23 2

Alternatively, you can open measurements with parameters on a spreadsheet straight from the Parameters view. Select a measurement folder or file in the Workspace and right-click a parameter in the Parameters view.

DAT A V IEW S

From the popup menu, select Spreadsheet. The query is opened on a spreadsheet.

23 3

Q U ER I ES

23 4

DAT A V IEW S

23 5

Editing Cell Format To format cells containing parameter data, right-click on the cell in the top left corner of the parameter data set and select Format Cells from the popup menu.

The Query tab of the Format Cells dialog opens. ♦ Please note that the Query tab is not displayed if Format Cells is not accessed via a rightclick on the cell in the top left corner of a parameter data set.

Show results, if selected, displays the parameter data set as a whole. If cleared, Show results minimizes the parameter data set into a single cell. Although minimized and not visible, functions can still be run on the entire parameter data set as each cell can still be referred to based on the original parameter data set structure. For more information on making references to a minimized parameter data set in a formula, see Use Case 19..: Retrieving Data from Minimized Data Sets on page 243.

Q U ER I ES

23 6

Show columns, if selected, displays data set column names. Short column names, if selected, displays short versions of data set column names. The Number tab of the Format Cells dialog allows you to define the format in which numbers are displayed within the selected cell(s).

General defines that the default settings for the content type are used. Number defines the cell content as numbers and allows you to set the number of decimals displayed. Percentage defines the cell content as a percentage and allows you to set the number of displayed decimals. Time defines the cell content as time and displays the value in the cell in hours, minutes, seconds, and milliseconds. The Alignment tab of the Format Cells dialog allows you to define the alignment of text within cells.

Text alignment

DAT A V IEW S

23 7

Horizontal defines the horizontal alignment of text within the selected cells as Default, Left, Center, or Right. Vertical defines the vertical alignment of text within cells as Top, Center, or Bottom. Text control Wrap text, if selected, enables word wrap within the selected cells. Merge cells enables you to merge selected cells into a single cell. Select the cells you want to merge, right-click on the selection, select Format Cells from the popup menu, and select Merge cells from the Alignment tab of the Format Cells dialog. The Font tab of the Format Cells dialog allows you to define the font and color of the text within cells.

Font defines the font of the text within cells. Color defines the font of the text within cells.

Q U ER I ES

23 8

The Border tab of the Format Cells dialog allows you to define borders for cells.

Border width defines the border thickness for cells as Thin (default), Medium, or Thick. Presets allows you to select which border groups are to be displayed. With None, no borders are displayed. With Outline, only the outlines of a cluster of cells are displayed as a border. With Inside, the borders of all cells within a cluster of cells are set as borders. Border buttons (i.e. Top, Middle, Bottom, Left, Middle, and Right) allows you to select manually which borders are to be displayed. The Patterns tab of the Format Cells dialog allows you to define cell background color.

Cell color defines the cell background color.

DAT A V IEW S

23 9

Filtering Data To filter out unwanted data based on values in a particular column, select the contents of the columns you want to filter, right-click on the selection, and select AutoFilter from the popup menu.

An AutoFilter drop-down menu is created based on values in the selected column(s).

To filter out all rows that do not contain a particular column value, select a column value from the dropdown menu.

Q U ER I ES

24 0

All rows that do not contain the selected value in the filter column will be filtered out. Selecting (All) from the drop-down menu displays all rows again. To remove an AutoFilter from a column, right-click the AutoFilter element at the column heading, and clear AutoFilter from the popup menu.

Creating Formulas You can enter a formula in any cell on the spreadsheet. The creation of a formula always begins with the equal sign (=). The next element identifies the mathematical function, e.g. AVG stands for the function Average. For more functions, see Adding Functions on page 241. =AVG The rest of the formula defines the source data for the function and is placed within brackets. =AVG() If the cells containing the source data for the function are located on another sheet, it is first necessary to identify the location of the data by entering the sheet name followed by the exclamation mark (!). =AVG(Sheet 2!) If the cells containing the source data for the function are located within a separate data set on the same spreadsheet, it is first necessary to identify the location of the data by entering the data set name (e.g. the name of a query opened on the spreadsheet) preceded by the asterisk (*) and followed by the exclamation mark (!). =AVG(*BLER DL!)

DAT A V IEW S

24 1

Next, a reference to the actual cells is added. A cell is referred to by a combination of the column letter and the row number that intersect at the cell’s location, e.g. A1. To refer to a range of cells, first identify the start point of the range (i.e. the first cell in the range), and separate it from the end point (i.e. last cell in the range) with a colon (:). If the range covers multiple columns, the start and end point references should be to the cells in the upper left and lower right corners of the range. =AVG(*BLER DL!A1:D555) If the range covers all cells in a column, the range can be referred to by using just the column letter as both the start and end point, instead of referring to individual cells with row numbers. =AVG(*BLER DL!A:A) To refer to more than one cell range, separate each range with a semicolon (;). =AVG(*BLER DL!A1:B12;C10:D16) For information on the general format of spreadsheet formulas, see one of the numerous helps and guides for spreadsheet applications available on the internet.

Adding Functions To perform a mathematical operation based on a group of cells, select the cells by holding the left mouse button down while moving the cursor over the selected cells. Once all intended cells have been selected, release the left mouse button and right-click over the selection. A popup menu opens. From the popup menu, select Insert Function | [function].

Q U ER I ES

24 2

The function is added below the selected cells. The cell with the function displays the result of the function. The formula of the function is displayed in the formula field on the topmost bar of the spreadsheet view.

If you wish, you can relocate the function by cutting and pasting. If you do not find an appropriate function amongst those displayed in the popup menu, select Insert Function | More Functions instead.

DAT A V IEW S

24 3

The Insert Function dialog opens.

When you select a function from the list, the info field below displays a description of the function. Select a function from the list and click OK. The function is added below the selected cells, as discussed above.

Use Case 19..: Retrieving Data from Minimized Data Sets It is possible to minimize parameter data sets on a spreadsheet to take up the space of only one cell. For minimizing data sets, see Editing Cell Format on page 235. To retrieve data from a minimized table, you first have to know which column in the maximized data set contains the data you want to retrieve. The first column in a separate data set is always considered to be Column A, the second Column B, etc., no matter how the data set is situated on the spreadsheet. Thus, if you are retrieving data from the first column of a minimized table, you are interested in the contents of Column A. The name of the query (i.e. the parameter data set that has been opened on the spreadsheet) has to be known as well in order for you to be able to refer to the right data set. The creation of a formula for data retrieval begins with the equal sign (=) to identify the string as a formula. Next, add the operator of the mathematical function you want to use. For instance, with the function Average, the operator is AVG. For more functions, see Adding Functions on page 241. Next, within brackets, define the data set on which the mathematical function is to be run. The data set definition string is generally of the following format: open bracket, asterisk, query name, exclamation mark, reference to the first cell in the range, colon, reference to the last cell in the range, and closed bracket. Thus, a formula for calculating an average based on values on rows 1-15 in Column A of the BLER DL data set would be of the following format: =AVG(*BLER DL!A1:A15). For more information on formulas, see Creating Formulas on page 240.

Q U ER I ES

24 4

Use Case 20.: Creating Reports and Report Templates Using Spreadsheets It is possible to create reports on spreadsheets and save them as report templates. These report templates can then be run on all measurement files that contain the events the report has been defined to look for. Select View | Workbook | Spreadsheet Grid in the Ribbonbar to open an empty spreadsheet.

DAT A V IEW S

On the empty spreadsheet, create a layout for the report.

24 5

Q U ER I ES

24 6

In Workspace, select a measurement and the parameter you want to add on the report. Click on the button to open the Parameter Launchpad.

In Parameter Launchpad, click on Statistics for a list of aggregates, select an aggregate (e.g. Count) from the list and drag and drop it to the cell you have designated for it in the spreadsheet layout.

DAT A V IEW S

24 7

Repeat the procedure with other relevant parameters until they are all on the spreadsheet.

If the report you are creating requires mathematical operations, select the cell you have designated for an operation and enter the appropriate formula into it. In the present example, the count of connected calls has to be divided by the count of call attempts to produce a ratio of successful calls. In order to present the ratio as a call success rate percentage, the result of the division has to be multiplied by hundred. At this point, the formula is of the following format: =((C3/C2)*100). For information on the general format of spreadsheet formulas, see one of the numerous helps and guides for spreadsheet applications available on the internet. Because division as an arithmetic operation always requires that the divisor (i.e. the cell C2) is not zero and because in a report of this type it is possible that the result of the count operation in C2 will be the value zero (i.e. if there are no call attempts), an additional condition following the format ‘if C2 is zero, the result of the division is zero’ has to be created to prevent the error that would otherwise occur. In spreadsheet formulas, this will be expressed in the following format: =IF(C2;((C3/C2)*100);0).

Q U ER I ES

24 8

If the result of the calculation is displayed in a format unsuitable for the value type (e.g. a percentage is displayed with multiple decimals), right-click on the cell containing the value, and select Format Cells from the popup menu. The Number tab of the Format Cells dialog opens.

Select a number format suitable for the value type, define the number of decimals to be displayed, and click OK. The report is now complete.

DAT A V IEW S

You can save the completed report as a template that can be run on any measurement file that contains the events required by the report. To save the report as a template, right-click on the spreadsheet and select Workbook | Save… from the popup menu.

The Save Workbook dialog opens.

24 9

Q U ER I ES

25 0

Filename defines the name of the report template. Popup menu defines the menus (e.g. Workspace Device Menu) in which the workbook will be saved. For more information on menus, see p.506. Groups defines the group (e.g. User) in which the workbook will be saved to. For more information on groups, see p. Error! Bookmark not defined.. To run the report on another measurement file, select a measurement from the Workspace section you defined as the location for the template (e.g. Workspace Device Menu) and right-click a measurement file.

DAT A V IEW S

25 1

From the popup menu, select the submenu you defined as the location for the template (e.g. User) and select the template. The report is run on the selected measurement file.

PROCESSING UPLINK VOICE QUALITY DATA 1. When measuring with Nemo Outdoor, make sure its clock is synchronized with the voice quality server clock. In Nemo Outdoor, select User Interface Measurements | Use time from GPS. In Nemo Server, select NTP (Network time protocol) from the NSM menu. Internet connection is needed in order for the server to use NTP time. If there is no internet connection available or NTP time cannot be set through, i.e. LAN, Nemo Outdoor clock and server clock must be synchronized manually. 2. Before measurement, the number of each server’s phone line must be configured manually to the voice quality server. By doing this, the numbers will also be set to the server end´s log file headers. 3. Load both Nemo Outdoor and server log files into Nemo Analyze. After this, you are able to use Nemo Outdoor files normally. If you want to see UL MOS for a specific Nemo Outdoor log file, select the file in question and UL MOS from the Parameters view. Nemo Analyze connects UL MOS values from the correct server file to the Nemo Outdoor file in question by comparing time and phone numbers.

Q U ER I ES

25 2

INDOOR MEASUREMENTS With Nemo Analyze you can also view indoor measurements on floor plans. Right-click on the measurement in the Workspace and select Adjust Coordinates.

In the Adjust Coordinates dialog, select the floor plan in the Map file field or click the Import Image as Map button to convert an image file into a map (see page 35). Click OK.

DAT A V IEW S

25 3

The selected floor plan is opened. First you need to place the coordinate markers in the right places. With the Arrow tool, click on the map and the active marker (highlighted with pink in the table on the right) will be placed there. The Longitude and Latitude values are updated as you place the markers on the map.

After you have placed all the markers, click the Update Coordinates button to save the marker coordinates.

Nemo Analyze will ask if you would like to open the route on a map. Click Yes, and the route is opened on a map.

Q U ER I ES

25 4

When you open the indoor measurement on the floor plan the next time, the route is automatically drawn on the map. You can color the route and use all the features available for maps.

DAT A V IEW S

25 5

NUMERICAL DATA VIEWS Numerical data views are useful, for example, for viewing benchmarking data from multi measurements: you can open several measurement files side by side and compare the values. You can open a numerical view, for example, by opening an empty workbook (View | Add data view| Workbook) and then adding a numerical view data view in the workbook: right-click on workbook, select Page | Add Data View | Numerical Data.

Drag a measurement or measurements in the view, and Nemo Analyze will display some network parameters for the file. If no data are shown on the table, the data are retrieved from the very beginning of the measurement. Double-click on the measurement file in the Workspace to view the Timeline view, and move the red time line forward to view captured data.

Q U ER I ES

25 6

You can edit the contents of the numerical data view.

Right-click on the view and select Properties.

The Visible parameters list offers a list of parameters that can be displayed in the numerical data view. With the Move up and Move Down you can change the order in which the different parameters appear in the numerical data view.

DAT A V IEW S

25 7

Title defines the column title. Alignment defines how the text is aligned.

The Color Sets list enables you to select the appropriate color sets for the parameters from the dropdown menu.

Q U ER I ES

25 8

INFO VIEWS Info views are used to display more detailed information, for example, about signaling, BTS sites and layer messages.

DAT A V IEW S

25 9

TIMELINE VIEW The Timeline view enables you to view and analyze a selected time range of a measurement file. For example, you can select to view data before and after certain events, e.g., call failures, to troubleshoot what may have caused the particular event. Or you can select a time range and generate a report for that range. Right-click on a measurement in the workspace and select Timeline or double-click a measurement to open the Timeline view. You can also open the Timeline view for multi measurements.

Q U ER I ES

26 0

The Timeline view displays the start and finish time of the file. The red synchronization line marks the current point in the measurement file. Current time is displayed below the synchronization line.

Highlight Parameter in Timeline View With Highlight Parameter you can visualize problem areas in the measurement. For example you can view certain events or parameters when their values are under/over certain user specified threshold. Right-click on the Timeline view and select Highlight Parameter.

In the Pick Parameter dialog, select the parameter you want to highlight and click OK. You can also find a given parameter from the list by using the filter field within the red box.

DAT A V IEW S

26 1

Double-click the Value field to define the event for the selected parameter and click Finish.

The parameter events will be highlighted.

Notifications in Timeline View You can also view notifications in the Timeline view. Right-click on the view and select Properties. In the Notifications tab, select the notifications you want to view in the Timeline view, for example, attach failures, and BLER, and click OK.

Q U ER I ES

26 2

The small red vertical bars represent the selected notifications. In the example below there are several attach attempt failures.

DAT A V IEW S

26 3

Range Selection in Timeline View Now you can take a closer look at the problem spot by selecting a sample, a range, of the file around the attach failures. Select the starting point of the range by double-clicking with the left mouse button and the ending point with a left click.

To generate a report based on the selected time range, right-click on the range and select Range | Report | Open from the popup menu. In the Open dialog, select a report template (*.rpt) and click Open. To generate a workbook based on the selected time range, right-click on the range and select Range | Workbook | [workbook folder] | [workbook].

Depending on your selection, a report or a workbook is generated from the data in the selected range.

Q U ER I ES

26 4

OTHER VIEWS Network Parameters The Parameters view displays some key network parameters. Right-click on a file in the workspace and select Network Parameters.

If the Parameters view is empty, right-click on the measurement in the Workspace to view the Timeline view. Move the red time line forward to a point in time where data have been gathered during the measurement.

Right-click on the view and select Pick Parameters to add more parameters. To remove parameters from the view, right-click on the view and select Properties. In the parameters page, clear the parameters you want to remove and click OK.

DAT A V IEW S

26 5

Measurement Settings The Measurement Settings view displays some information about the settings that were used when the file was recorded. Right-click on a file in the workspace and select Measurement Settings.

Q U ER I ES

26 6

Properties The Properties view displays information about items that are selected in the main window. The view is by default docked to the right side of the main window. Move your mouse over the Properties tab for the window to appear. If the Properties tab is not visible, open the Properties view by selecting View | Properties. You can also drag the view elsewhere on the Analyze main window. If you want to dock it back to the side of the main window, double-click on the Properties view.

DAT A V IEW S

26 7

Query Clipboard The Query Clipboard displays a list of queries that have been copied, and which can further be pasted into views. The view is by default docked to the right side of the main window. Move your mouse over the Query Clipboard tab for the hidden window to appear. If the Query Clipboard tab is not visible, enable the Query Clipboard by selecting View | Query clipboard. You can empty the clipboard by clicking the Clear button. You can also drag the view elsewhere on the Analyze main window. If you want to dock it back to the side of the main window, double-click on the Query Clipboard.

To paste a query into a view, right-click on a view and select Query | Paste. The Paste Query dialog displays the contents of the Query Clipboard. Select the query to be pasted and click OK.

Q U ER I ES

26 8

Database Loader The Database Loader displays the progress of file upload, file conversion, and file upload queue.

With Cancel and Cancel All buttons, you can abort the upload of either the currently uploaded measurement file or the upload of all measurement files in the upload queue. To move a measurement file to the top of the list of uploaded measurements, right-click on the file and select Move To Top.

DAT A V IEW S

26 9

Window Browser The Window Browser displays a list of controls (workbooks, pages, data views) open in Nemo Analyze at a given moment. Right-click on the items to access the Properties dialogs for each control.

Q U ER I ES

27 0

Messenger The Messenger enables you to publicly chat with other users of the database. If you are logged to a database server with multiple users, all other current users are displayed as Current users.

To send a public message seen by all other users, type a message to the Message field and press Enter. The message is displayed in the Received messages field.

Output The Output panel displays some program and error messages and the SQL statements that are being processed. The view is by default docked to the bottom of the main window. Move your mouse over the Output tab for the hidden window to appear. If the Output tab is not visible, open the Output view by selecting View | Output. Switch between the Log and the SQL pages by clicking on the tabs at the bottom of the view. You can also drag the Output view from the bottom of the Analyze main window elsewhere on the screen. If you want to dock it back to the bottom, double-click on the view.

You can clear the Output view by right-clicking on it, and selecting Clear. You can also save the contents of the Output view in a log file by selecting Write to File and type a name for the file. The log is saved in a text file (.txt). Select Copy to Clipboard to copy the contents on a clipboard to be pasted in another application.

DAT A V IEW S

27 1

Q U ER I ES

27 2

MANUAL LAYOUT EDITOR The Manual Layout Editor makes it possible to create custom layouts for workbook pages. Each Manual Layout Editor page can contain any number of user-defined data views laid out in a manner defined by the user.

Creating a Layout To open Manual Layout Editor, select View | Workbook | Manual Layout Editor from the Ribbonbar. To add a layout editor data view to an open workbook, select Layout | Manual Layout Editor from the Ribbonbar.

An empty workbook opens. To add data views to the workbook, right-click on the workbook and select Insert Data View | [data view type] from the popup menu. Note that in order to add or edit data views in a Manual Layout Editor workbook, Edit Mode must be selected in the popup menu.

DAT A V IEW S

27 3

Once an empty data view has been created, the user can place it anywhere on the workbook window. The user can also change the size of the data view by simply holding down the left mouse button on the red border of the data view and dragging the selected side of the data view to the desired direction. The user can also create other empty data views, defining the layout for the workbook page before beginning to add content to the data views. However, data views can be added, edited and removed later on as well by right-clicking on the Manual Layout Editor workbook and selecting Edit Mode from the popup menu.

Data views can be removed by selecting a data view, right-clicking and selecting Item | Delete from the popup menu.

Q U ER I ES

27 4

Selecting Item | Properties from the popup menu opens the Properties dialog. Border size defines the thickness of the data view border. Selecting Draw shadow draws a distinguishing shadow under the selected data view.

Adding Content to Manual Layout Editor Data Views Measurement files and folders, parameters, BTS files and map files can be drag and dropped to the empty data views.

A measurement folder (or file) and a parameter are both selected in the Workspace and then drag and dropped (holding left mouse button down) on an empty data view in the Manual Layout Editor workbook.

DAT A V IEW S

27 5

Once you have finished editing the layout, right-click on the Manual Layout Editor window, and clear Edit Mode in the popup menu. This will lock the layout. If you later want to edit it some more, simply right-click on the Manual Layout Editor workbook and select Edit Mode from the popup menu.

W O RKBO O K S

27 6

WORKBOOKS Viewing measurement data in Nemo Analyze is extremely flexible and user-configurable. The various views are organized into workbooks, pages, and data views. A workbook is the main component that contains all the different pages and data views. There is a selection of ready-made workbooks but you can also create new workbooks. To open an empty workbook, select View | Add data view | Workbook. It is also possible to open a workbook with a predefined layout, e.g. 2x2 view arranged in a grid by selecting View | Add data view | Workbook Layout.

W O RKBO O K S

27 7

To open a ready-made workbook on a measurement file/folder, right-click the measurement file/folder and select [workbook folder] | [workbook] (e.g. UMTS | UMTS full details) from the popup menu.

To cancel a running query during workbook execution, click Cancel in the Executing Queries dialog. To cancel the execution of all queries within the workbook, select Cancel All.

W O RKBO O K S

27 8

ADDING DATA VIEWS In order to view measurement data in the workbook you will need to create a data view. Right-click on the workbook and select Page | Add Data View | [data view type]. An empty data view will be opened in the workbook.

Now you can add data in the data view. You have two options. You can either drag a measurement file in the data view or right-click on the view and select Pick Parameter. In the latter case, first choose the graph type.

In the Pick Parameter dialog select the measurement file in the Measurement field and pick the parameter to be viewed. In the Filter field you can type the name of the parameter you want to add in the data view to locate all the options, in this case all instances of BLER, more quickly from the list.

W O RKBO O K S

27 9

The selected view is opened.

You can create several pages and each page can contain several data views. To add more data views on the same page, right-click on the view and select Page | Add Data View | [data view type]. If you select Data View | Insert | [data view type], the existing data view is replaced with the new one.

W O RKBO O K S

28 0

Right-click on the empty grid view, select Pick Parameter, select the parameter to be displayed and click OK. Now you have a workbook with one page that contains two data views. To add more pages to you workbook, see the next chapter.

W O RKBO O K S

28 1

W O RKBO O K S

28 2

ADDING PAGES You can have several pages in a workbook each containing one or more data views. Right-click on a view and select Page | Add Page.

An empty page is added to the workbook and you can now open data views on the page. You can switch between the pages from the tabs at the bottom of the workbook.

W O RKBO O K S

28 3

You are also able to add a page containing several data views by right-clicking on a view and selecting Page | Add Page Layout | [page layout type]

An empty page is added to the workbook and you can now open data views on the page e.g. by dragging and dropping a parameter. You can switch between the pages from the tabs at the bottom of the workbook.

W O RKBO O K S

28 4

SAVING A WORKBOOK After you have opened all the relevant views, right-click on a view and select Workbook | Save to save the workbook for later use.

The Save Workbook dialog opens.

Filename defines the name of the report template. Popup menu defines the menus (e.g. Workspace Device Menu) in which the workbook will be saved. For more information on menus, see p.506. ♦ Note: Workbooks containing bar or line graphs should always be saved only in the Device Menu. This is because the nature of these graph types requires the information to be ordered by time, which in turn can be done only within a single log file at a time.

W O RKBO O K S

28 5

Groups defines the group (e.g. User) in which the workbook will be saved to. For more information on groups, see p. Error! Bookmark not defined..

After defining the filename and the destination popup menu and group, click OK.

W O RKBO O K S

28 6

EXPORTING WORKBOOKS An open workbook can be exported as a PDF or as a set of image files (image per page).

Exporting Workbooks as PDF/MS Word/MS PowerPoint Files To export an open workbook as a PDF, Microsoft Word or Microsoft PowerPoint file, select File | Export | Workbook to File.

The Save As dialog opens.

To save the report as a PDF/MS Word/MS PowerPoint file, type in a file name in the File name field and click Save.

W O RKBO O K S

28 7

Exporting Workbooks as Image Files To export an open workbook as image files, select File | Export | Page Image to clipboard, and select export type from the drop-down menu.

Page image to clipboard saves the workbook page currently open on the clipboard. Page image to file saves the workbook page currently open as an image file. Workbook images to file saves all workbook pages as separate image files.

W O RKBO O K S

28 8

COPYING A WORKBOOK After you have opened all the relevant views, right-click on a view and select Workbook | Create Copy for Measurement or click the Create copy of workbook button in the toolbar to make a copy of the workbook for another measurement file.

Select the measurement for which you want to open the workbook and click OK. The workbook is opened with the new data.

W O RKBO O K S

28 9

WORKBOOK PROPERTIES You can rename a workbook by right-clicking on the workbook and selecting Workbook | Properties. In the Workbook Properties dialog, type a new title for the workbook and click OK.

PAGE PROPERTIES In the Page Properties dialog you can change the settings of each page. Right-click on a page and select Page | Properties.

W O RKBO O K S

29 0

On the Page page you can define a title for the page. The name is displayed at the bottom of a workbook. Here you can also define the page size.

If the Fit to window option is selected, all the layers are displayed in the visible area of the page. This means that when a new layer is added, the space for each layer gets smaller. With the Fixed size option you can define an exact size in pixels for the page. This will give more space for each layer. With the scroll bar you can scroll up and down the page to view all layers

EXAMPLE WORKBOOK The example workbook, GSM, contains four pages, each of them displaying different GSM-related KPIs. The first page displays three different RF Parameters in line graphs stacked on top of each other in separate graphs. The Numerical data table on the right displays information in numerical form.

W O RKBO O K S

Page two contains Serving and Neighbor cell data in line and bar graphs.

Page three contains L3 signaling data in a grid, and the decoded data in an info view.

29 1

W O RKBO O K S

29 2

The fourth page contains a map with the measurement route. The route is colored with the RX level color set.

RE P O RT S

29 3

REPORTS With Nemo Analyze, you can select the optimal approach for each statistical reporting task. A set of predefined MS Excel compatible report templates for optimization and benchmarking purposes are available. The reports can be customized using the Nemo Analyze Spreadsheet Report Designer and MS Excel, and new custom reports can be easily created.

WORKBOOKS The fully customizable and automatable Nemo Analyze workbooks provide you with a completely new angle on statistical reporting. Each workbook can contain several pages and data views. All open workbooks and all data views within the workbooks are automatically synchronized in time. The comprehensive selection of data views includes spreadsheets, maps, grids, line graphs, bar graphs, pie charts, layer 3 messages, surface grids, and color grids. Nemo Analyze features a full set of readymade workbooks with pages and views for all the relevant KPIs. Nemo Analyze workbooks can be scheduled to be run automatically on predefined measurement file folders. Nemo Analyze paired with an automatic measurement solution such as Nemo Autonomous can indeed equal to automatic up-todate measurement reports popping up on your desktop as and when measurement sessions are completed. All custom settings, such as workbooks, queries, layouts, color sets, KPIs, etc., can be imported and exported to enable sharing between colleagues. For performing reporting using Nemo Analyze workbooks, see Workbooks.

SPREADSHEETS Nemo Analyze spreadsheets offer a spreadsheet functionality that follows the current de facto standard in spreadsheet applications, fully integrated with Nemo Analyze's drive test data-specific post-processing features. You can drag and drop parameter aggregates and statistics on a single spreadsheet based on multiple measurement files and KPIs, and calculate e.g. success rates by employing the standard range of arithmetic operations and other capabilities of the spreadsheet approach. The resulting spreadsheet can be saved as a report template and subsequently run as a workbook on any measurement data. For performing reporting using Nemo Analyze spreadsheets, see Spreadsheets.

W O RKBO O K S

29 4

REPORTING WITH SPREADSHEET REPORT DESIGNER With Spreadsheet Report Designer, you are able to create custom report templates containing statistics, charts, and map plots of drive test data in MS Excel (.xlsx) format. Any metric from the Parameters view, including custom KPIs created with KPI Workbench can be used to produce source data for the report template. It is also possible to show Workbook pages of Nemo Analyze as images on the report template. This is particularly useful for populating map plots in the Excel report. The data should be processed as much as possible beforehand in Nemo Analyze so that the Excel report shows the preprocessed statistics/metrics rather than raw values. For example, it is better to export average Ec/N0 to the report rather than raw Ec/N0 samples and then calculate the average using Excel formula. This is because the performance of MS Excel is not optimal when processing thousands of rows of data. It is also possible to create an empty report template with all the necessary formatting and charts directly in MS Excel, open the resulting .xlsx document in the Spreadsheet Report Designer and use it as baseline for the report.

Creating and Opening a Report Template To create a report template, select View | Spreadsheet report | Spreadsheet Report Designer in Nemo Analyze to open the Spreadsheet Report Designer and a new report template.

You are also able to create a report template layout beforehand using MS Excel. To do this, open a blank workbook in MS Excel by selecting File | New | Blank workbook. Add the necessary worksheets and charts and format their appearance. Once you have finished defining your MS Excel workbook, save it by selecting File | Save As.

RE P O RT S

29 5

If you have already created a report template with Spreadsheet Report Designer or MS Excel and want to use or edit it, select Open from the Spreadsheet Report Designer toolbar. A dialog box showing all existing templates in C:\Nemo Tools\Nemo Analyze\Reports folder appears. Select a spreadsheet report template (.srt file), from the list of files and click Open.

Once you have created or opened a report template in Spreadsheet Report Designer, you need to define which data will be exported when the report is run and the export location within the MS Excel report template. To add a parameter to the template, select a cell on the report template and drag and drop the parameter into the report template. However, to improve the responsiveness of MS Excel, it is recommended not to use MS Excel in calculating raw values that contain tens of thousands of rows. For example, you should not export to MS Excel any isolated Ec/NO values and calculate average values with MS Excel´s formula. Success rates, etc. instead are well-suited to be calculated using MS Excel. For example, you can export from Nemo Analyze “Number of call attempts” and “Number of call attempt failures”. MS Excel will then calculate and show call setup failure rate, i.e. “number of call attempt failures”/”number of call attempts”.

W O RKBO O K S

29 6

You are also able to add a parameter to the template by left-clicking on a parameter in the Parameters view to open a dialog in which you are able to define in which format the parameter is shown on the report. It is possible to show the raw values (do not calculate statistics) or to show average or other precalculated statistical figures in the report. After having defined the settings, click Add Parameter to [the selected cell].

RE P O RT S

29 7

To insert elements into a worksheet, select a cell on the report template and click Insert in the Spreadsheet Report Designer toolbar.

Workbook Image: Adds an image of a Workbook page to the worksheet. The workbook image is added to the cell that is currently selected. If a range of cells is selected, the image is automatically sized to cover the selection area. This function is typically applied to showing map plots in reports. Statistics Table: Inserts a statistics table to the worksheet. Manual SQL Query: Allows the user to type a query directly into the worksheet.

Rows: Inserts new rows to the worksheet. Columns: Inserts new columns to the worksheet. Worksheet: Inserts a new worksheet to the workbook. Chart: Inserts a chart to the worksheet. First select the data range, then select Insert | Chart and double-click to open SpreadsheetGear Chart Explorer. Picture: Inserts a bitmap picture to the worksheet. Text Box: Inserts a text box to the worksheet. Auto Shape: Inserts a shape such as box or ellipse to the worksheet.

W O RKBO O K S

29 8

Line: Inserts a line to the worksheet.

Modifying a Spreadsheet Report Template You are able to format the report template, e.g. to add headers and titles and insert relevant workbooks. Modifications can be performed in MS Excel or in Spreadsheet Report Designer. To make changes to the report template in MS Excel, select Run Report in Spreadsheet Report Designer. Select Edit Report Template in Excel in the Report Configuration dialog. After making the changes, close MS Excel and continue using the Report Designer.

RE P O RT S

29 9

Define the settings of the elements you have added to the worksheet by clicking the View tab on the toolbar.

Workbook Explorer defines settings related to workbooks. Range explorer defines settings related to cells. Chart explorer defines settings charts. Shape explorer defines settings related to shapes. Report Configuration Editor allows you to define the values of the input variables of certain metrics and KPIs in the Nemo Analyze Parameters view at the time of query execution. For example, “Ec/N0 CPICH Nth best selected carriers”, where N and the channel range are defined by the user at the time of query execution. Such metrics can be used in the report template, and the values of the input variables are controlled with Report Configuration Editor. Zoom in / Zoom Out / Zoom level allow you to adjust settings related to zooming. To perform test runs for the reports, select Run Report from the toolbar and select for which measurement you want to run the report and click Run Report Once all the workbooks and layouts are ready, you can save the template as a .srt file by clicking File | Save as. When the report in finished, you are able to run it the same manner as normal Crystal Reports. The Format tab on the toolbar allows you to change formatting options of cells, rows and columns.

W O RKBO O K S

30 0

The spreadsheet opens in Analyze Spreadsheet Report Viewer:

You are able to save the report as Excel workbook form or as PDF by clicking on the toolbar Save as Excel Workbook or Save as PDF. The Report Scope dialog box appears, allowing you to filter the report to show results from selected system, band, and area. This step is not, however, mandatory.

Finally, click OK to generate the Excel report. The report opens in Analyze Spreadsheet Report Viewer. To save the document as Excel workbook or as PDF by clicking on the toolbar Save as Excel Workbook or Save as PDF.

RE P O RT S

30 1

Showing PDF/CDF Charts in Reports These use cases explain two ways of showing PDF/CDF charts in reports.

Use case 1: Exporting a Workbook from Nemo Analyze 1. In Nemo Analyze workspace, right-click on a parameter from the Parameters view and select Statistics By from a pop-up menu and select how you wish to filter the statistics.

W O RKBO O K S

30 2

2. The workbook displaying the PDF/CDF chart opens:

Modify the workbook if needed. For more information, see “Workbooks”. 3. Save the workbook by right-clicking on it and selecting Workbook | Save from the pop-up menu

RE P O RT S

30 3

4. In the Save Workbook dialog, define the name of the report template, the menus in which the workbook will be saved and the group (e.g. User) in which the workbook will be saved to. Click OK.

5. Open Spreadsheet Report Designer. Select Insert | Workbook image and select the workbook from the pop-up menu list.

6. Save the report template and run the report.

W O RKBO O K S

30 4

Use case 2: Creating a Chart in Spreadsheet Report Designer 1. Open a report template in Spreadsheet Report Designer 2. Select a cell or a range and left-click on a parameter in the Parameters view. Doing this opens a dialog in which you are able to define in which format the parameter is shown on the report. After defining the settings, click Add Parameter to [the selected cell].

The ResultSet shows the following statistics: Lowerbound and Upperbound define the upper and lower boundaries of each cumulation/density bucket Cumulation shows the cumulation as a percentage. Cumulation sample show the absolute cumulation in samples Density shows the density as a percentage. Density sample shows the absolute density in samples Group shows the value if you have benchmarked the measurement by a group. 3. Select Run Report in Spreadsheet Report Designer. Then, select Edit Report Template in Excel in the Report Configuration dialog.

RE P O RT S

30 5

4. In MS Excel, select the results by defining a range and go to Insert in the ribbonbar and select how you wish the results to be displayed (as a column, line, pie chart, etc.). For further instructions on how to use MS Excel, please refer to documentation provided by Microsoft.

5. After making the changes, save the MS Excel file and close MS Excel. You can now continue using the Spreadsheet Report Designer.

Showing Map Plots in Report Templates This use case explains showing map plots as workbook images in reports. 1. First, a workbook with map plots must be created in Nemo Analyze. For more information, see “Workbooks”. Alternatively, predefined workbooks, such as “UMTS map summary”, can be used. You are able to modify the Workbook in Nemo Analyze. It is, for example, possible to change default map (displayed in bold) by right-clicking on the map file in Workspace view and selecting Default Map from the pop-up menu. You can also set the side panel visible/invisible by right-clicking on the map and selecting/deselecting Side Panel from the pop-up menu. For more information, see “Workspace”.

W O RKBO O K S

30 6

Please note that you cannot modify a Workbook image once it has been inserted to the worksheet. Modify the original workbook instead and then insert it as a Workbook image to the worksheet. See “Workbooks” for more information on how you can further to modify workbooks. 2. Open a report template in Spreadsheet Report Designer. Click Insert | Workbook image to select from the pop-up menu a workbook containing map plots and define on which page of the workbook the map plot to be inserted is located.

RE P O RT S

30 7

3. Save and run the report. The workbook image is displayed on the Report Viewer.

4. In Analyze Spreadsheet Report Viewer, you are able to save the report as Excel workbook form or as PDF by clicking on the toolbar Save as Excel Workbook or Save as PDF.

W O RKBO O K S

30 8

Running Reports You can run a report over any folder or measurement file by right-clicking on the folder or file in the Measurements section in Nemo Analyze and selecting Report from the pop-up menu. After this, select a report from the following pop-up menu. If a saved report has not been loaded into the database yet, select Open and select the report from the list.

The Report Scope dialog box appears, allowing you to filter the report to show results from selected system, band, and area. This step is not, however, mandatory.

RE P O RT S

30 9

Finally, click OK to generate the Excel report. The report opens in Analyze Spreadsheet Report Viewer. The spreadsheet opens in Analyze Spreadsheet Report Viewer:

You are able to save the report as Excel workbook form or as PDF by clicking on the toolbar Save as Excel Workbook or Save as PDF.

W O RKBO O K S

31 0

REPORTING WITH MICROSOFT EXCEL With Nemo Analyze’s Microsoft Excel export templates, you can export query result data sets from Nemo Analyze to a selected location within an existing MS Excel document. The exported parameters and the export locations within the MS Excel workbook are saved as a report template. The template can be subsequently run on any measurement data. The feature allows you to use the full data formatting functionality of MS Excel in reporting and make use of any existing, custom-made MS Excel spreadsheets. In the following example, Sheet1 of the existing target MS Excel sheet displays the final report output which is generated based on input data sets on Sheet2. In other words, as Sheet2 acts as a basis for the final output on Sheet1, the data sets should in this case be exported to the appropriate columns on Sheet2. ♦ Note: Before doing anything else, it is recommended to open the data set intended for export in grid data view to check the data set’s number of columns and column order. The data set will be exported from Nemo Analyze in fixed table format and thus it may be necessary to make changes to the column order of the target MS Excel sheet before the export operation.

The target MS Excel workbook must be saved to Nemo Analyze’s default Reports directory. To find out what the default folder for reports is, select View | Options from the Ribbonbar, and Environment | Default Paths | Reports in the Options dialog.

RE P O RT S

31 1

To create an MS Excel export template, select Tools | Spreadsheet Old Excel Export Template. The Excel Export Template dialog opens.

Excel workbook defines an existing MS Excel workbook as the target spreadsheet for the export. Excel template defines a name for the new MS Excel export template. Run macro on finish, when selected, runs the chosen macro in Excel once the export has been performed. Exported queries displays all queries selected for export. Add opens the Excel Template Row dialog, enabling you to define a new query. It is also possible to drag parameters from the Parameters view to the excel report creation template dialog. Modify allows you to modify an existing query. Select the query in the Exported queries field and click the Modify button. Delete allows you to delete an existing query. Select the query in the Exported queries field and click the Delete button. Preview displays the columns of the query data set selected in the Exported queries field. Exported images displays all data view images selected for export.

W O RKBO O K S

31 2

Add opens the Excel Export Template dialog, enabling you to define a new image. Modify allows you to modify an existing image. Select the image in the Exported images field and click the Modify button. Delete allows you to delete an existing image. Select the query in the Exported images field and click the Delete button. To browse for an existing Excel workbook (to be used as the target spreadsheet for the export), click the … button.

RE P O RT S

31 3

The Open dialog opens.

Select the Excel workbook you want to use as the target spreadsheet for the export and click Open. The path of the target spreadsheet is displayed in the Excel workbook field. To rename the export template, type a new name to the Excel template field. To define a new query for export, click the Add button. The Excel Template Row dialog opens.

Sheet name defines the target sheet in the target MS Excel workbook for the exported parameter data set. Cell defines the target cell in the target MS Excel workbook for the exported parameter data set. In the present example, A2 is selected (instead of e.g. A1) because the first row of Sheet2 is reserved for column names (see screenshot on page 294). ♦ Note: As the parameter data set is likely to contain more than one column, the target cell defined here will act as the upper left corner of the exported parameter data set. Thus, if the exported parameter data set contains three columns, and the target cell is defined as C2, the first-row cells of the second and the third columns will be D2 and E2 respectively. The Preview field in the Excel Export Template dialog displays the columns included in the selected parameter data set.

W O RKBO O K S

31 4

♦ Note: To make the exported data sets as versatile as possible in terms of the existing operations in the target MS Excel workbooks, all irrelevant data, including the Nemo Analyze column names, are removed from the exported data sets. Parameter defines the exported parameter data set. Click the … button to browse for a parameter. With Modify you are able to modify the parameter data set that has been selected in the Parameter box. Right-clicking the Config… button opens the Statistics Configuration dialog which enables you to modify the settings of statistics parameters. Select OK and the Analyze Wizard – Start dialog opens.

Pick measurement parameter opens the Parameters view. The Parameters view enables the use of both ready-made parameters and previously saved custom KPIs (i.e. parameters created using the KPI workbench or SQL). By default, custom KPIs can be found in the Parameters view under the User item. For Generic query wizard, see page 351. For Manual query, see page 356. For Correlate parameters, see page 358. Selecting Pick measurement parameters in Analyze Wizard – Start dialog opens the Analyze Wizard – Measurement Parameters dialog.

RE P O RT S

31 5

Select a parameter and click Finish. Previously saved custom KPIs can be found in the Parameters view under the User item. The Excel Template Row dialog opens.

Define Sheet name, Cell, Parameter, and Statistics. With Modify you are able to modify the parameter that has been selected in the Parameter box. Right-clicking the Config… button opens the Statistics Configuration dialog which enables you to modify the settings of statistics parameters. Select OK. The defined query is now displayed as a row in the Exported queries field. The Preview field displays the columns the selected query contains and the column numbers they will take up in the target spreadsheet. If you want to add another query, click Add… in the Excel Export Template and repeat the procedure above. To edit an existing query, select the query in the Exported queries field and click the Modify button.

W O RKBO O K S

31 6

To delete an existing query, select the query in the Exported queries field and click the Delete button. It is also possible to drag parameters from the Parameters view to the Excel report creation template dialog. In the Exported images section it is possible to define images to be exported into the Excel repot. Images can be exported from a file or from Analyze workbook. To define a new data view image for export, click Add… in the Exported Images section. The Export Image dialog opens

File defines the name of an image file that will be exported to Excel. Workbook defines the workbook that will be exported to Excel as an image. Page, Image position, Image size, and Relative size define to which page of the workbook the image is to be exported, the desired position and the size of the image, and the size of the image in percentage. Sheet name defines the name of the Excel sheet that the image is exported to. Once Page name, Cell, and Parameter have all been defined, select OK. If you want to add another data view image, click Add in the Excel Export Template and repeat the procedure above. To edit an existing image, select the image in the Exported images field and click the Modify button. To delete an existing query, select the image in the Exported images field and click the Delete. Once all the intended queries and images have been added to the template, click OK. The Excel export template is saved to the default Report directory. To find out what the defined folder is, go to View | Options | Environment | Default Paths | Reports. To load the Excel export template to the report template database, first click on the bottom of the workspace panel. The Reports page of the Workspace opens.

icon on the

RE P O RT S

31 7

Next, double-click on the Excel export template in the Report Folder field. The Excel export template is added to the database and is now displayed in the Loaded field.

To run the Excel export template on a measurement file/folder, right-click on the measurement file/ folder and select Report|[Excel export template].axt from the popup menu.

W O RKBO O K S

31 8

The parameter data sets defined in the export template are exported to the defined page (Sheet2 in the present example) of the MS Excel workbook.

Microsoft Excel generates the final output page (Sheet1) based on the input page (Sheet2).

RE P O RT S

31 9

W O RKBO O K S

32 0

REPORTING WITH CRYSTAL REPORTS In Nemo Analyze you can run statistics in the form of reports over a single or multiple measurement files. The reports include essential network and application performance KPIs as defined by standards specifications, such as, ETSI, ANSI, etc. In addition, smaller-scale statistics can be run over a single parameter in the User Interface. Reporting in Nemo Analyze is based on Crystal Reports. The Crystal Report Viewer tool is embedded in Nemo Analyze. Reports can be exported to PDF, Excel, etc., as in standard Crystal Reports. Default report templates with all the most essential KPIs are provided in Nemo Analyze, but you can also create your own report templates. For this you will need the Crystal Reports Professional edition (independent third-party software).

Generating Reports Generating reports is very easy. Right-click on the measurement file from which the report will be generated and select Report. Select one of the existing report templates, e.g., CDMA performance report.rpt.

RE P O RT S

32 1

The report is generated and opened in a new workbook. ♦ Note that this may take a few minutes, depending on the processing power of the computer and on the complexity of the report.

W O RKBO O K S

The report contains several pages with all relevant network KPIs in different graphs and tables.

32 2

RE P O RT S

32 3

Generating Reports from Multiple Files You can also generate reports from multi-measurements or from folders containing several files. Rightclick on the multi-measurement file name, or on the folder, and select Report and the report template.

In the dialog you can define what kind of data will be included in the report. After making all the selections, click OK and the report is generated.

W O RKBO O K S

32 4

System and Band define from which cellular systems and frequency data will be included in the report.

Begin time and End time define the time period from which data is included in the report. By selecting the Area option, and clicking the Define Area.. tab, you can enter the Select Area dialog below.

RE P O RT S

32 5

Select Area defines the geographical area from which data is included in the report. Select a map in the Filename field, and select an area on the map with your mouse. Right-click on the map to change the tool, for example, to zoom in on the map.

Exporting Reports After you have generated a report you can export it to another format. Click the Export Report button in the report workbook.

In the Export dialog, select the output format and the destination for the exported file. Click OK.

W O RKBO O K S

32 6

In the Export Options dialog, select the report pages that will be exported and click OK.

The report is saved in the location and format defined.

Configuring Reports The report contents and layout are user-configurable. Select the Reports page in the Workspace, right-click on the report template that you want to configure, and select Configure.

RE P O RT S

32 7

In the Report Configuration dialog you can edit the report contents. On the General page you can select which statistics are shown in the report. You can also type a Report description and a Report title that will be shown on the report front page. Show bins defines whether numerical data is shown in cumulation and density histograms.

W O RKBO O K S

32 8

Under the other items you find a list of available parameters. For each parameter you can define some properties, such as, the lower and upper bound, threshold, and channel numbers. The selection depends on the parameter.

The changes will affect all reports that are generated using this template. For benchmarking reports you need to define how the benchmarking report is grouped. Open the Report Configuration dialog for a benchmarking report, click on General. In the Benchmark by field select the grouping factor and click OK.

32 9

CREATING CUSTOM QUERIES ♦

NOTE: Using the easy-to-use graphical user interface of KPI Workbench, the user is able to perform all SQL-specific tasks and more without proficiency in the SQL language.

Nemo Analyze is based on an SQL database. The data is stored and retrieved from the database using SQL queries via the standard ODBC interface. The results of the SQL queries can be further processed using the KPI workbench, Nemo Analyze’s graphical, flowchart-based scripting engine. The results of the SQL queries and the KPI Workbench scripts can be visualized using Nemo Analyze’s comprehensive selection of data views, or any third party post-processing tool supporting ODBC connectivity. This section describes the guidelines for making custom KPIs with both SQL (see SQL Queries on page 330) and the KPI Workbench (see CUSTOM KPI Workbench on page 358). SQL queries represent a powerful tool for complex data filtering and data processing when the data is in scalar format. However, SQL has some downsides as well: it is impossible to create queries that track certain event sequences, such as changes in a particular parameter value from row to row. It is also impossible to merge data from more than two data sets into a single result set based on time. Moreover, the use of SQL queries requires knowledge of the Nemo Analyze database schema and proficiency in SQL. The KPI workbench enables the creation of complex queries, including time-based merging of multiple inputs, and the tracking of particular event sequences. The graphical user interface makes it also easier to use than SQL. To summarize the differences between the KPI Workbench and SQL, the KPI workbench is a more powerful tool for data customization, whereas SQL is sometimes more convenient when filtering or formatting raw data. For a user without previous experience with SQL, the KPI workbench is recommended as the primary data customization tool.

W O RKBO O K S

33 0

SQL QUERIES Getting started As a prerequisite, the following documents and tools are recommended as a reference for developing SQL queries: 1. SQL editor. Queries can be written with the Nemo Analyze database browser (see 2. Database Browser on page 358) but there are also many specifically SQL-oriented third-party editors available. Good freeware tools are also available, such as http://gpoulose.home.att.net/Tools/QTODBC61.msi 3. Nemo File Format specification. The document describes the Nemo measurement file format on an event-by-event basis. The file format specification can be downloaded from the Nemo User Club, or accessed via Nemo Analyze by selecting Help | Documentation | Nemo file format from the Ribbonbar. 4. Open access SQL reference. The document describes the supported SQL syntax and can be downloaded from the Nemo User Club. In addition to the Open access SQL, Anite has added some proprietary scalar functions and stored procedures for common tasks needed in drive test data processing. The description of Anite’s proprietary scalar functions and stored procedures can be accessed by selecting Help | Help | Help topics from the Ribbonbar and searching the help with the keywords scalar functions or stored procedures. 5. Nemo Analyze database schema. Database schema can be accessed and queried by selecting Help | Documentation | Database schema from the Ribbonbar. The schema opens as a Crystal Reports document. Note that querying the schema may take several minutes. The schema can be exported as a PDF document.

Nemo Analyze Database Schema Data in a relational database is stored as relations which are perceived by the user as tables. Each table represents an object or an event (e.g. employee, sales order, etc.). Each row in a table represents a unique instance of the object or event. Each column represents a different class of information defining the object or event, e.g. first name, last name, salary, customer name, order charge, etc. In the Nemo Analyze database, the table structure is based on the event structure of the Nemo log file format. That is, each event in the Nemo file format has a corresponding table in the database. For instance, a BLER event is always recorded when the mobile’s Block Error Rate changes. When the log file is loaded into the Nemo Analyze database, each BLER event is parsed as a new row in the BLER table. When referring to a table in a query, the syntax is “[schema name]”.”[table name]”. For example, "Nemo.UMTS"."BLER”, where the schema is Nemo.UMTS and the table BLER.

Relations between tables If rows in a given table can be associated with rows in another table, the tables are said to have a relationship between each other. Generally, these relationships can be of three different types: one-toone, one-to-many, and many-to-many. The Nemo Analyze database schema allows one-to-one and one-to-many relations.

33 1

One-to-one relation means that each row in a given table can have a relation with a single row in another table. In one-to-many relation, each row in a given table can have a relation with multiple rows in another table. These relations can be defined by two columns in a table: the columns primary key and foreign key. Each table by necessity has a primary key. Primary key is a column that uniquely identifies each row within a table. In Nemo Analyze database, the primary key column is always named as oid. If a table has relations with other table(s) it will also contain a foreign key column for each related table. The foreign key column contains the value of the primary key values (oid) of the associated row(s) in the other table. Foreign key column names always include the prefix the_, as with the following names: the_parent, the_event, and the_connection. For examples of how the relations are used in practice, please see the following two chapters that describe the mapping of static and dynamic events to database tables.

Mapping of Nemo log file events to database tables The data in Nemo log files is written in event-based format. All data related to a same object (e.g. Block Error Rate) is written as a single event. Each different event type in Nemo file format has a corresponding table structure in the database. Events can be split into two categories. Static events always have the same amount of information elements, i.e. columns. Dynamic events have a varying number of information elements. A typical example of a static event is SHO. It reports soft handover events in UMTS. It contains always the same information elements, including SHO status, number of scrambling codes added to the active set, etc. An example of a dynamic event is ECNO. The ECNO event reports the RSCP and Ec/N0 of all measured active, monitored, detected, and undetected cells. The number of measured cells constantly varies based on the location of the measurement device in the network. The number of information elements, i.e. columns, in the ECNO event varies accordingly. The diagram below illustrates the mapping of SHO events to different database tables. A similar diagram applies to all static events. For each SHO event in the log file, there is one row written in the SHO table. All soft handover-specific information elements within the SHO event are written to the corresponding columns in the SHO table. Generic information elements common to all events are written in the Event table. Such information elements include time, latitude, longitude, GPS distance, etc. There is a one-to-one relation between the SHO table and the Event table. The column the_event in the SHO table is a foreign key, pointing to the oid column in the Event table. In other words, each unique row value in the column the_event in the SHO table corresponds with a unique row value in the column oid in the Event table. Based on this correspondence, the two tables can be correlated. The Device table contains a row for each log file loaded into the database. The only information column in this table is the log file extension. There is a one-to-many relation between the SHO table and the Device table. The SHO table contains a row for each SHO event from each log file loaded into the database. Each row of the SHO table belonging to same log file points to the same row in the Device table. That is, the value in the column the_device in the SHO table is the same on all rows that come from the same log file, corresponding with a single row value in the column oid in the Device table.

W O RKBO O K S

33 2

The Measurement table contains a row for each measurement loaded into the database. It contains all measurement-specific information columns, including the log file title. It should be noted that the term measurement refers to one or multiple log files collected at the same time. If a Nemo Outdoor Multi measurement is made with 4 terminals, there will be a single measurement session and 4 log files. In this case, the measurement title is the same for all log files and the log files are differentiated from each other using different file extensions. When these files are loaded into the Nemo Analyze database, there will be 4 rows in the Device table, one for each log file, and one row in the Measurement table. So there is a one-to-many relation between the Measurement and Device tables. That is, the value in the column the_measurement in the Device table is the same on all rows that come from the same measurement session, corresponding with a single row value in the oid column of the Measurement table.

33 3

The diagram below illustrates the mapping of ECNO events into different database tables. The ECNO event in the log file contains Ec/N0, RSCP, channel number and scrambling code for each measured cell, and carrier RSSI for each measured channel. Because the number of information elements in each ECNO event varies, the data has been split to multiple different tables in order to achieve efficient data storage in the database. As with all dynamic size events, the data is split to multiple tables in the database. There is a single row written in the ECNO table for each ECNO event in the log file. The ECNO table consists of columns such as the number of active set cells, the number of monitored set cells, etc. The relations between the tables ECNO, Event, Device, and Measurement are similar to those of the SHO event, see previous example. There is a one-to-many relation between the tables ECNO and Channel. In the Channel table, there is a row for each carrier RSSI value reported in an ECN0 event. All the rows in the Channel table that belong to the same ECN0 event have the same value in the column the_parent. The value in the column the_parent equals the oid value of the matching row in the ECN0 table. There is also a one-to-many relation between the tables ECNO and Cell. For each measured cell in the ECNO event, there is a row in the Cell table. All the rows in the Cell table belonging to the same ECN0 event have the same value in the column the_parent. The value in the column the_parent equals the oid value of the matching row in the ECN0 table. As an example, consider an ECN0 event that includes measurement results from six different cells. Two of these cells are in channel x, and the rest in channel y. When parsed to the database, the event will produce one row in the ECN0 table, two rows in the Channel table, and six rows in the Cell table.

W O RKBO O K S

33 4

The structures of all tables in the database follow the same principle as the SHO event and the ECNO event above. All tables in the database are structured based on the same principle with either the SHO event or the ECNO event (discussed above). Each column, table, and relation is described in detail in the Nemo Analyze database schema.

Views – Automatically joined tables As mentioned earlier, each information element is stored as a separate table based on the event structure of the Nemo log file format. General information, including time, lat, long, and log file name, are stored in the tables Measurement, Device and Event. These tables have relations with measurement data tables, as described in the dynamic and static event examples above. Typically, when a query is made, the data of interest, such as RX level, Ec/N0, etc. is retrieved together with corresponding general information which at the minimum includes time, latitude and longitude. This means that the tables Event, Device and Measurement must be joined with the table containing the data of interest.

33 5

The Nemo Analyze database schema contains views for each data table that results from joining the Event, Device and Measurement tables. In other words, a view is a virtual table that joins the tables Event, Device, and Measurement as one. When using a view in an SQL query, the tables are joined by the ODBC driver and not by the user. The views should always be used when there is need for viewing time, lat, long, etc. information together with the data of interest. This is for two reasons. Firstly, the views are easier to use because queries become simpler when there is no need for performing the join operation as part of the SQL query itself. Secondly, the query performance is also a little bit better when using views instead of query-based join operations. A “+” character at the end of the table name identifies a table as a view. For example, the view corresponding with the SHO table is titled SHO+. In the screenshot below, all the columns in the BLER+ table are listed. It can be seen that BLER, time, lat, long, measurement name, etc. are all available in the same table.

W O RKBO O K S

33 6

The screenshot below demonstrates how views are used as part of queries. Both of the illustrated queries return the same information, i.e. time and bler. The upper query represents a situation where the join is performed as part of the SQL query, i.e. without using the relevant view. The query retrieves bler from the BLER table and time from the Event table. The Event and BLER tables are joined with the WHERE clause of the query. The lower query represents a situation where the relevant view is used, i.e. the query retrieves both time and the parameter bler from the BLER+ table.

33 7

Database timestamps The Nemo Analyze database stores time in two different formats. The column sql_time in the Event table contains the timestamps of each measurement event in a standard, readable SQL timestamp format. The column time in the Event table contains the timestamp in proprietary binary format. The Nemo measurement file format is time-based, as opposed to sample-based. In other words, a new “sample” is created on a timeline only when changes occur in the monitored parameter and the temporal length of the samples depends entirely on how often changes occur in the parameter value. This also means that the samples are not equal in weight, as the duration of each sample affects the weight of the sample. In order to calculate correct statistics, each sample has to be weighted by its duration. Also, to ensure that line graphs and map plots are drawn accurately, the duration of each sample must be taken into account. The binary time stored in the column time (of the Event table and of all the views) contains both the timestamp and the duration of the sample. The column sql_time contains only the timestamp. When custom queries are used in Nemo Analyze, the binary timestamp time should always be used. Nemo Analyze converts the binary time to timestamp at runtime, and automatically utilizes the sample duration (embedded in the timestamp) in route colouring and line drawing.

W O RKBO O K S

33 8

The screenshot above shows how the sample duration in milliseconds can be retrieved from the binary timestamp using the scalar function TI_INTERVAL(). It is also evident that the duration of some events is 0. These event parameters (such as dropped call, call attempt failure, and cell reselection) do not have duration, as they represent events that occur at a point in time. Therefore, the scalar function TI_INTERVAL(time) returns the value 0 ms. All other parameters, such as Rx level, Ec/N0, throughput, BLER, etc., contain a duration. When using Nemo Analyze queries with third-party tools, sql_time and TI_INTERVAL(time) must be used instead of the binary timestamp. Moreover, sql_time must always be used as part of the query when sorting the result data set by time or when using conditions (e.g. x.sql_time > y.sql_time).

Filtering log files The queries are usually run on a subset of log files that is narrowed down from all the files in the database. The optimal query performance is achieved using Anite’s proprietary, non-SQL filters in the end of the queries. These are called hints. Because of the physical structure of the Nemo Analyze database, all irrelevant data is filtered out and not processed. The hints point directly to the relevant log file(s), enabling outstanding query performance regardless of the database size. Hints are added to the end of the query in the following format: /* MEAS({measurement_file_name_1}:{file_extension}|{measurement_file_name_2}:{file_extensio n}|....) */ The screenshot below shows an example of how the filter should be integrated into a query. An example of the same query in SQL format is also provided. It should be noted that log file filtering queries are unnecessary when creating custom SQL queries that are intended for use with Nemo Analyze only. This is because Nemo Analyze automatically adds the hints to the queries at runtime.

33 9

Value enumeration All textual parameters with a discrete list of possible values are written to the database as numbers. In other words, each textual value has a corresponding numerical value. Examples of such parameters include system (GSM, UMTS, etc), handover type, call disconnect status, call failure cause, etc. The textual values of all parameters of this type are stored in a ValueEnum table (see screenshot below).

The two screenshots below show two versions of the same query. The first one returns values in numerical format. The second one uses the VAL_TO_STRING(, ) scalar function for retrieving the textual value for each numerical value. The scalar function VAL_TO_STRING retrieves the value enumeration automatically from the ValueEnum table.

It should be noted that the use of the scalar function VAL_TO_STRING is unnecessary when creating custom SQL queries that are intended for use with Nemo Analyze only. This is because Nemo Analyze displays the value enumeration automatically.

W O RKBO O K S

34 0

Connections The connection sessions measured during a drive test are stored as connection tables. The following connections and connection tables exist: Voice, Handover, Attach, PDPContextActivation, Data, RRC, DataTransfer, MMS, SMS, POC, LAU, RAU, and Ping. The connections often have a hierarchical structure. For example, the DataTransfer connection always has the Data Connection table as its parent connection. The Data Connection table has the PDPContextActivation table as its parent connection. Finally, the PDPContextActivation table has the Attach table as its parent connection. All data recorded during a measurement session has by necessity a relation (or relations) with the connection tables. Examples of such data include Tx power (recorded only during voice call or packet session), application throughput (recorded only during data transfer), and BLER (recorded only during packet session and voice call). As an example, the screenshot below illustrates the relations between the tables DAS and Attach. Attach is a connection table, containing a row for each Attach session. The DAS table contains a row for each uplink and downlink application throughput sample. Each row of the DAS table is related to the corresponding connection in the Attach table via the_connection foreign key. The Attach table has also relations with the GAA (Attach attempt), GAC (Attach connected), CAD (Attach disconnected), and CAF (Attach failure) tables. All the different connection tables follow the same principle. They contain all data specific to a particular session, including the data events that define the beginning and the end of the session.

The connection tables can be used for various purposes: Grouping data per session, e.g. average Data throughput per session: SELECT the_connection, AVG("app_throughput_downlink")

34 1

FROM "Nemo"."DAS+" WHERE "throughput_status"=1 GROUP BY the_connection

Filtering in only those throughput samples that were recorded during a data transfer: Connection types: 0="Unknown" 1="Voice" 2="Handover" 3="Attach" 4="PDP contect activation" 5="Data" 6="RRC" 7="Data transfer" 8="MMS" 9="SMS" 10="POC" 11="LAU" 12="RAU" 13="Ping"

Filtering in only those throughput samples that were recorded when PDP context was active and Access point was Internet:

The two scalar functions utilized in the examples above can be defined as follows:

CONN_IS_SHARED(conn1.”oid”, conn2.”oid”). Checks if the two connections are actually the same, or if one of the connections is the parent of the other CONN_IS_TYPE(conn.”oid”, numeric_exp). Checks if the connection is of a particular type. The connection types are listed in the example above.

Correlating tables based on time Most tables do not have relations with each other. However, it is still often necessary to correlate data from these unrelated tables based on time. For example, the tables Rx level and Rx quality are not related, but the user may still want to correlate them based on time to find instances where bad Rx quality has coincided with good Rx level. Generally, for performing correlations of this type, it is recommendable to use Nemo Analyze’s “Correlate parameters” functionality or the KPI Workbench. However, it is also possible to correlate the two tables using SQL and proprietary keywords, as explained in the two examples above.

W O RKBO O K S

34 2

Sample-based correlation The procedure for correlating two data sets sample by sample based on time is as follows: 1. Define the tables to be joined using a FROM clause: FROM table x, table y 2. Define the x.”time” = y.”time” condition using a WHERE clause Note that the order in which the tables are entered to the FROM clause is extremely important. When the table x is the first one in the FROM clause: • Each sample from the table y is retrieved and checked based on the following condition: if there is an x sample that has the same timestamp as the y sample OR if the x timestamp falls to the validity time interval of the y sample • When the table y is the first one in the FROM clause, the comparison is performed vice versa Note that the comparison is not bi-directional. If there is a significant difference in the sample periods of the tables x and y, the table that has a smaller sample period should be selected as the last one (y) in order to get highest possible resolution 3. Define the condition x.the_device = y.the_device using a WHERE clause. This limits the timebased correlation into individual measurement files, improving the performance of the query and ensuring that the correlation is performed within a single log file. 4. Add the hint /* OPTIONS(USE_TIME_SCOPE) */ at the end of the SQL query. This enables the join based on time scope. The following screenshot shows an example correlation of the best active set cell Tx power and RSCP, filtered from periods where RSCP is < -95 dBm • Tx power is in the table ”Nemo.UMTS”.”TXPC” and RSCP is in the table ”Nemo.UMTS.ECNO”.”Cell”. There is no established relation between the tables. • All Tx power samples that fall within the validity time interval of an RSCP sample with the value ) bit shift element would perform in the input data set a three-digit shift to the right. The Ceiling function rounds a real number to the next larger integer based on each of the values in the column defined as the Left column in the element properties. Right column should be set to . The value entered into the Right value field defines the rounding method, i.e. 1 defines rounding to the next integer, 10 defines rounding based on ten, etc. The Floor rounds a real number to the next smaller integer based on each of the values in the column defined as the Left column in the element properties. Right column should be set to . The value entered into the Right value field defines the rounding method, i.e. 1 defines rounding to the next integer, 10 defines rounding based on ten, etc. The Log (logarithm) function calculates the logarithm of each of the values in the column defined as the Left column in the element properties. Right column should be set to . The value entered into the Right value field defines the base for the logarithm.

40 5

Exponentiation performs exponentiation on each of the values in the column defined as the Left column in the element properties. Right column should be set to . The value entered into the Right value field defines the exponent. Root performs an Nth root (square root, cube root, etc.) operation on each of the values in the column defined as the Left column in the element properties. Right column should be set to . The value entered into the Right value field defines the root, e.g. 2 defines the operation as square root. The Round function performs rounding of a real number to the nearest integer based on each of the values in the column defined as the Left column in the element properties. If the fraction part of the number is =0.5, the number is rounded to the next larger integer. Right column should be set to . The value entered into the Right value field defines the rounding method, i.e. 1 defines rounding to the next integer, 10 defines rounding based on ten, etc. Define the operation properties and click OK. The element changes color from red to green, signifying that the element is operational. Even if you are still going to add more elements to the KPI, it is recommended to test the operation of the KPI at this point by connecting it to the Output element. Then, select a measurement or several measurements from the Folder Contents section on the Measurements page of the Workspace, right-click on the Workbench background, and select Run Script from the popup menu.K. For more information, see Running and Testing KPIs.

W O RKBO O K S

40 6

Time Functions: Resample As Nemo file format is event-based, samples with varying time ranges are logged only when the parameter value changes. This means the sample interval is not constant. Resample allows the data to be resampled at a periodic, user-definable time interval. Thus for instance 0.5-second and 1.3second RSCP samples with values -86 and -87 respectively, would constitute five samples of value 86 and 13 samples with value -87 when resampled at a 100-millisecond interval. ♦

Note: Resampling data using a sample period that is longer than the original sample period can reduce the accuracy of the data and may cause some data to be lost.

To add a Resample element to the KPI, drag and drop the element to the Workbench. Connect the data set to be resampled to the upper (i.e. input) sockets of the Resample element by pressing the left mouse button down on the output socket of the data set and holding down the mouse button while dragging a connector line from the data set output socket to the input socket of the Resample element.

Right-click the Resample element and select Properties from the popup menu. The Resample tab of the Properties dialog opens.

40 7

Interval defines the interval at which the data set is to be resampled. The drop-down menu allows you to define the unit of time as millisecond (ms) or second (s). Define resampling interval and click OK. The element changes color from red to green, signifying that the element is operational. Even if you are still going to add more elements to the KPI, it is recommended to test the operation of the KPI at this point by connecting it to the Output element. Then, select a measurement or several measurements from the Folder Contents section on the Measurements page of the Workspace, right-click on the Workbench background, and select Run Script from the popup menu.

For more information , see Running and Testing KPIs on p. 410.

W O RKBO O K S

40 8

Time Functions: Time Shift Time Shift allows you to modify the timestamp and time range of the input dataset. For example, time shift can be used to create a time range for event-type input that is logged as a point in time, such as Dropped call. Defining a time range surrounding this point in time allows you to correlate the time range surrounding the event with other parameters (e.g. ec/n0 best active set) to find out what the values of the correlated parameters were not only at the time of the event but also before and after the event. To add a Time Shift element to the KPI, drag and drop the element to the Workbench. Connect the data set(s) on which the time shift is to be performed to the upper (i.e. input) sockets of the Time Shift element by pressing the left mouse button down on the output socket of each data set and holding down the mouse button while dragging a connector line from the data set output socket to the input socket of the Time Shift element.

Right-click the Time Shift element and select Properties from the popup menu. The Time Shift tab of the Properties dialog opens.

Time offset enables you to define an offset in relation to the point in time the event occurred. Selecting backward from the drop-down menu defines the offset point before the event. Selecting forward from the drop-down menu defines the offset point after the event. Define the distance of the offset point from the event by entering an amount of time in the time field and by setting unit of time as either seconds (s) or milliseconds (ms).

40 9

Duration allows you to define the direction and length of the time range from the offset point defined in Time offset. Selecting backward from the drop-down menu defines the time range as ending to the offset point defined in Time offset. Selecting forward from the drop-down menu defines the time range as beginning from the offset point (defined in Time offset). Define the length of the time range from the offset point (defined in Time offset) by entering an amount of time in the time field and by setting unit of time as either seconds (s) or milliseconds (ms). For example, to define a time range that begins 10 seconds before the event and ends 10 seconds after the event, define Time offset as backward 10 s and Duration as forward 20 s. Define the properties of the Time Shift and click OK. The element changes color from red to green, signifying that the element is operational. Even if you are still going to add more elements to the KPI, it is recommended to test the operation of the KPI at this point by connecting it to the Output element. Then, select a measurement or several measurements from the Folder Contents section on the Measurements page of the Workspace, right-click on the Workbench background, and select Run Script from the popup menu.

For more information, see Running and Testing KPIs.

W O RKBO O K S

41 0

Running and Testing KPIs To test the operation of the KPI, make sure all elements are of green color (operational), connect the last element to the Output element. Select a measurement or several measurements from the Folder Contents section on the Measurements page of the Workspace. Right-click on the Workbench background, and select Run Script from the popup menu.

Once the script has been successfully run, there is a good opportunity for fine-tuning the KPI based on the output, for instance, by adding a sort element to the KPI to make the results more explicit, defining even more optimal states and triggers if using the state machine, or further filtering the data if the output still contains irrelevant information. You can also hide irrelevant columns in the output data set by double-clicking on the Output element and clearing the irrelevant columns on the Results tab of the Properties dialog. Ideally, the KPI should produce only the target data without any irrelevant information and in as explicit form as possible.

Saving KPIs as Components To save the KPI as a component that can later be reused as part of more complex KPIs, right-click on the Workbench background and select Save Component from the popup menu. ♦ Note: In order for the component to work properly as part of a KPI, it must be operational and complete with Parameter and Output elements when saved.

The saved KPI component can be found from the menu structure on the right, under the menu item Components.

41 1

To add a component to a KPI, drag and drop the component to the Workbench. The Component Type dialog opens.

To open the component as a single element, select Single component and click OK.

To open the component in multiple-element format that allows you to edit the properties of individual parts of the component, select Multiple nodes (will reset model) and click OK.

W O RKBO O K S

41 2

For editing the properties of individual KPI elements, see the topic pertaining to the relevant KPI element above.

Saving Custom KPIs To save a KPI, right-click on the Workbench background and select Save from the popup menu. If the script is not operational, the Save option will not be displayed in the popup menu.

The Analyze Wizard – Properties dialog opens.

Name defines a name for the KPI. Name is displayed in the Parameters view under the User item. Title defines a title for the KPI. Title is displayed when the KPI has been dragged and dropped to the Workbench

41 3

Description defines a description for the KPI. The description of a KPI can be accessed by rightclicking the KPI in the Parameters view and selecting Description from the popup menu. Select Next. The Analyze Wizard – Column Aliases dialog opens.

In the Column Aliases dialog you can define how the retrieved data is displayed in the various data views. These settings are optional. Click Finish. The saved custom KPI can be found in the Parameters view under the User item.

Reopening Custom KPIs for Editing Go to the User item in the Parameters view. Select Tools | KPI Workbench in the Ribbonbar to open the KPI Workbench. Select the KPI you want to open for editing and drag and drop it to the Workbench. The Component Type dialog opens.

To open the component in a format that allows editing, select Multiple nodes (will reset model) and click OK.

W O RKBO O K S

41 4

For editing the properties of individual KPI elements, see the topic pertaining to the relevant KPI element above.

Defining KPI Execution Method and Value Constants The Properties control in the bottom right corner of the screen allows you to define the KPI execution method and value constants. If the intended purpose of the new KPI calls for switching the KPI execution method, or if you wish to define value constants for use during the KPI creation process, these both should be done before beginning to define the actual KPI.

KPI execution method You are able to select one of the following three KPI execution methods from the drop-down menu. •

Execute for all executes the query simultaneously on all measurement files.



Execute for measurement executes the query on all measurement files belonging to the same measurement session.



Execute for file executes the query for each measurement file one at a time.

41 5

Defining value constants To define values that can be referred to in scripts with a reference, right-click on the empty Constants field in the bottom right corner of the screen and select Add Constant from the popup menu.

The Add Constant dialog opens.

Name defines the reference string which is replaced by the constant value (e.g. 10000, see screenshot below) in a script. In script, the usage of the reference string example is {$example}. Click OK. The Constants field now displays a row with the reference string example.

Click the content field (on the right of the reference string), enter the constant value (e.g. 10000), and press Enter. The constant example can now be referred to with the string {$example} when defining the properties of various KPI elements. For example, when defining a filter element, the reference string can be used instead of the actual value 10000.

W O RKBO O K S

41 6

Use Case 21.: Creating Complex Filters Using Multiple Conditions Filter makes it possible to filter out all the values in a data set that do not fulfill a defined condition. For instance, a filter for Scrambling Code 0 would filter out all other scrambling codes than 1 and 2. The following example creates a filter that filters out all scrambling codes other than those belonging to the ranges 12-21, 29-30, and 74-88. As a formula, the logic can be presented in the following format: (scr. code 11) OR (scr. code= 29) OR (scr. code = 74). To add a Filter element to the KPI, drag and drop the Filter element to the Workbench. Connect the data set to the upper (i.e. input) sockets of the Filter element by pressing the left mouse button down on the output socket of each data set and holding down the mouse button while dragging a connector line from the data set output socket to the input socket of the Filter element. Right-click the Filter element and select Properties from the popup menu.

The Filter tab of the Properties dialog opens.

41 7

Click the Add button to add a filter. The Condition dialog opens.

Define the first condition, e.g. scr. code 11, and select OK. The Properties dialog now displays the two conditions.

The first of the three value ranges, i.e. 12-21, has now been defined. The logic of the filter element follows that of a binary tree, and thus one node can always have only two child nodes. In other words, as the first already defined condition pair takes up one of the two possible nodes on the highest level, there can be only one available node left on that level. However, in order for us to be able to create a filter that can accommodate also situations where there are values from only one of the ranges, three nodes of equal importance are needed, one for each value range. We can accomplish this by adding the two remaining condition pairs, i.e. (scr. code= 29) and (scr. code = 74) as children to the remaining free higher-level node. In practice, the original formula is restructured in the following manner: (scr. code 11) OR ((scr. code= 29) OR (scr. code = 74)). Next, the second higher-level node is created as a parent for the remaining two condition pairs. To create the second higher level node, select one of the two existing conditions and click Add.

41 9

Define the condition, e.g. scr. code = 74, in the Condition dialog and click OK. A new level is added automatically to the binary tree.

Next, to complete the third condition pair, select the previously created condition, i.e. scr. code >= 74, and click Add. Define the condition, i.e. scr. code 0

BLER < 20

Once the missing handovers have been isolated from the data using the state machine, it will be necessary to correlate the missing handover events with the parameter Call dropped to find out if any of the dropped calls in the data occurred while a handover was missing. From the Parameters view, drag and drop the parameters BLER, Ec/N0 best active and Ec/N0 Nth best to the Workbench.

42 5

When you drag and drop the parameter Ec/N0 Nth best to the Workbench, the Analyze Wizard – Filters dialog opens.

Make sure the Value field contains the value 1 and select Finish.

Step 2: Combining raw data sets Next, as the mathematical function Subtraction requires the two values between which the operation takes place to be found within the same data set, to calculate the Ec/N0 difference, the two parameter data sets have to be combined into a single data set. As we are interested in two Ec/N0 values that occur simultaneously, we can use the correlation All Values Within Time Range to combine the two data sets. From the Correlations menu, drag and drop All Values Within Time Range to the Workbench and drag connector lines from the output sockets of the parameters Ec/N0 best active set and Ec/N0 Nth best to its input sockets by holding the left mouse button down.

W O RKBO O K S

42 6

Step 3: Adding Operations From the Math menu, drag and drop Subtraction (-) to the Workbench and connect All Values Within Time Range to it.

Right-click on the Subtraction element and select Properties from the popup menu. The Properties dialog opens.

From the Left column drop-down menu, select ec/no. From the Right column drop-down menu, select 1. best Ec/N0. Leave the Right value field empty. Type Ec/N0 difference to the Result title field.

42 7

At this point, there are two input data sets: BLER and Ec/N0 difference. To combine these data sets into a single data set, you need to select a correlation method that does not remove any data from either of the sets, namely Union. From the Correlations menu, drag and drop Union to the Workbench and connect BLER and Ec/N0 difference to it.

To test the output at this point, connect the Union element to the Output element. Then, select a measurement or several measurements from the Folder Contents section on the Measurements page of the Workspace. Right-click on the Workbench background, and select Run Script from the popup menu. The output grid opens as a new workbook.

W O RKBO O K S

42 8

From the output grid, it is evident that although the two tables and their time columns have been merged, the rows are not ordered by time. As most operations require the input data to be ordered by time, you need to sort the data set before performing any further operations on it. From the Sorting menu, drag and drop the Ascending sort element to the Workbench and connect the Union element to it.

42 9

Right-click on the Ascending sort element and select Properties from the drop-down menu. The Properties dialog opens.

Select time from the Column drop-down menu and click OK. The Ascending sort element is now operational.

W O RKBO O K S

43 0

To test the output again at this point, connect the Ascending sort element to the Output element. Then, select a measurement or several measurements from the Folder Contents section on the Measurements page of the Workspace. Right-click on the Workbench background, and select Run Script from the popup menu.

43 1

The output grid is now ordered according to time. From the Operations menu, drag and drop State Machine to the Workbench and connect the Ascending sort element to it.

W O RKBO O K S

Right-click on the State Machine element and select Properties from the drop-down menu. The Properties dialog opens.

Select Add. The State dialog opens.

43 2

43 3

To create a state called OK, type OK to the Name field and click OK. In the Properties dialog, click Add again. In the State dialog, type Bad BLER to the Name field and click OK.

Again, in the Properties dialog, click Add. In the State dialog, type Missing handover to the Name field and click OK.

All states have now been created. As the state OK serves the function of the idle state in this use case, select the state OK from the Initial state drop-down menu. This defines OK as the starting point for the operation of the state machine. Next, define a condition that has to be fulfilled in order for the state machine to move from the Initial State (i.e. the state OK) to the state Bad BLER. To define transitions from the state OK, select OK from the States field, and click Modify. An empty State dialog opens. The name of the state, i.e. OK, is displayed in the Name field.

W O RKBO O K S

43 4

To create a transition from the state OK to another state, click Add. The Transition dialog opens.

Next, define the target state (i.e. the state to which the transition occurs) by selecting Bad BLER from the Target drop-down menu. Because the only relevant state in terms of the KPI is Missing handover and the output should not include any data from the state OK, leave the Output field empty. The Condition dialog opens.

Next, define the condition that causes the transition to occur from the state OK to the state Bad BLER. For the purposes of this use case, it has been decided that for a BLER value to be considered bad, it

43 5

has to be 20 or more. To define this as a transition condition, select bler from the Column drop-down menu, select >= (i.e. greater or equal) from the Operator drop-down menu, and type the value 20 to the Value field. When the condition has been defined, click OK to return to the Transition dialog. The condition bler >= 20 is now displayed in the Conditions field.

As there is no need to define any more conditions for the transition from the state OK to the state Bad BLER, click OK in the Transition dialog to return to the State dialog. In the State dialog, the transition to Bad BLER is now displayed in the Transitions field.

As there is no need to define any more transitions from the state OK, click OK in the State dialog to return to the Properties dialog.

W O RKBO O K S

43 6

To define transitions from the state Bad BLER, select Bad BLER in the Properties dialog, and click the Modify button.

Again, an empty State dialog opens. The name of the state, i.e. Bad BLER, is displayed in the Name field.

Two transitions are needed from the state Bad BLER: one that returns to the initial state OK in case the BLER value is less than 20 again, and another to move from the state Bad BLER to the state Missing handover if the Ec/N0 difference between the best active set and the absolute best set is less than 0. To create a new transition, click Add in the State dialog. The Transition dialog opens.

43 7

Next, define the target state (i.e. the state to which the transition occurs) by selecting Missing handover from the Target drop-down menu. Because the only relevant state in terms of the KPI is Missing handover and the output should not include any data from the state Bad BLER, leave the Output field empty. Click the Add button. The Condition dialog opens.

Define the condition for the transition from the state Bad BLER to the state OK. Select bler from the Column drop-down menu, select < (i.e. smaller than) from the Operator drop-down menu, and type the value 20 to the Value field. When the condition has been defined, click OK to return to the Transition dialog. The condition bler < 20 is now displayed in the Conditions field.

Click OK to return to the State dialog.

The transition from Bad BLER to OK is displayed in the Transitions field of the State dialog.

W O RKBO O K S

43 8

Click Add to add a transition from Bad BLER to Missing handover. The Transition dialog opens.

Next, define the target state (i.e. the state to which the transition occurs) by selecting Missing handover from the Target drop-down menu. Because the only relevant state in terms of the KPI is Missing handover and the output should not include any data from the state Bad BLER, leave the Output field empty. Click the Add button. The Condition dialog opens.

Define the condition for the transition from the state Bad BLER to the state Missing handover. Select Ec/N0 difference from the Column drop-down menu, select < (i.e. smaller than) from the Operator drop-down menu, and type the value 0 to the Value field. When the condition has been defined, click OK to return to the Transition dialog. The Transition dialog opens with the condition Ec/N0 difference displayed in the Conditions field of the Transition dialog.

43 9

As there is no need to define any more conditions for transitions from the state Bad BLER, click OK in the Transition dialog to return to the State dialog. In the State dialog, the transitions to the states Bad BLER and Missing handover are now displayed in the Transitions field.

As there is no need to define any more transitions from the state Bad BLER, click OK in the State dialog to return to the Properties dialog.

To define transitions from the state Missing handover, select Missing handover in the Properties dialog and click the Modify button.

W O RKBO O K S

44 0

The State dialog opens.

Two transitions are needed from the state Missing handover: one that returns to the initial state OK in case the BLER value is less than 20 again, and another to move from the state Missing handover to the state Bad BLER if the Ec/N0 difference between the best active set and the absolute best set is greater or equal to 0. To create a new transition, click Add. The Transition dialog opens.

44 1

Define the target state (i.e. the state to which the transition occurs) by selecting OK from the Target drop-down menu. As the output should include the data from the state Missing handover, enter the name Missing handover to the Output field. Once the target state has been defined, click Add to add a condition for the transition. The Condition dialog opens.

Define the transition from the state Missing handover to the state OK. Select bler from the Column drop-down menu, select < (i.e. smaller than) from the Operator drop-down menu, and type the value 20 to the Value field. Once the condition has been defined, click OK to return to the State dialog. The condition bler < 20 is now displayed in the Conditions field of the Transition dialog.

When the transition has been defined, click OK to return to the State dialog. The transition to OK is now displayed in the Transitions field of the State dialog.

W O RKBO O K S

44 2

As one more transition is needed from the state Missing handover, click the Add button in the State dialog. The Transition dialog opens.

Define the target state (i.e. the state to which the transition occurs) by selecting Bad BLER from the Target drop-down menu. As the output should include the data from the state Missing handover, enter the name Missing handover to the Output field. Next, click Add to define the condition for the transition from the state Missing handover to the state Bad BLER. The Condition dialog opens.

44 3

Select Ec/N0 difference from the Column drop-down menu, select >= (i.e. greater or equal) from the Operator drop-down menu, and enter the value 0 to the Value field. When the condition has been defined, click OK to return to the Transition dialog.

Click OK to return to the State dialog. The transition to Bad BLER is now displayed in the Transitions field of the State dialog.

Click the OK button to return to the Properties dialog. Click the OK button in the Properties dialog. The State Machine element is now operational. The states where the BLER value rises and a handover is missing have now been isolated. To find the events where missing handovers lead to dropped calls, we need to add the parameter Call dropped to the KPI. Drag and drop the parameter Call dropped from the Parameters view to the KPI Workbench.

W O RKBO O K S

44 4

As the only relevant dropped calls in terms of the KPI are the ones that occur during the state Missing handover, the most optimal correlation for combining these two data sets is All Values Within Time Range. Drag and drop an All Values Within Time Range element from the Correlations menu to the KPI Workbench. For the output data set to include all Missing handover time ranges and only those dropped call events that occur during these time ranges, the state machine has to be the primary data set and the parameter Call dropped the secondary one. Connect the state machine to the leftmost input socket of the All Values Within Time Range element. Connect the parameter Call dropped to the next socket. Finally, connect the All Values Within Time Range element to the Output element.

44 5

Step 4: Running and Testing the KPI To run the KPI, select a measurement or several measurements from the Folder Contents section on the Measurements page of the Workspace. Right-click on the Workbench background, and select Run Script from the popup menu. The final output includes only the rows with Missing handover events from the measurement data, and if there are Call dropped events within the time range of the Missing handover events, these will be displayed as well.

W O RKBO O K S

44 6

To save the custom KPI for later use, right-click on the Workbench background and select Save. The Analyze Wizard – Properties dialog opens.

Enter Dropped calls resulting from missing handover to the Name and Title fields and click Next. The Analyze Wizard - Column Aliases dialog opens. Click Finish. The KPI can now be found in the in the Parameters view under the User item.

44 7

ANALYTICS Analytics feature is part of the Nemo Analyze Professional feature package. Analytics consists of new summary tables in the Analyze database for voice/video call, data, MMS, SMS, and handover events. The information in the Analytics tables is essentially the same as in the standard database tables. The key difference is that Analytics tables do not have the physical per measurement file federation as the standard tables. This makes Analytics queries to execute significantly faster over large (>100 log files) datasets when comparing to corresponding standard queries. Analytics tables are populated with queries executed over the standard tables. Thus the process has two steps, first the log file(s) are loaded into the Nemo Analyze database as before. Then, AnalyzeAnalytics.exe, a process running on the background, will automatically detect new files added to the database, and run a set of queries over the files and save the query results into the Analytics tables. Analytics can be enabled from the View | Options | Database | Queries | Use Analytics to preprocess measurement data. Analytics tables are visible for the end user via new set of queries in the Parameters view, under Analytics branch. The queries can be used to plot events on the map, calculated statics, etc. in a similar manner as standard queries. Analytics queries can be also used in custom workbooks and report templates. Note that the file loaded to the database cannot be queried with Analytics queries immediately after it appear in the database. There is an additional delay to process the files, that is, to run the queries to populate Analytics tables. The extra delay is approximately 4min per 1 hour of raw log file data. When using Nemo Analyze Enterprise Analytics starts automatically in the database server.

W O RKBO O K S

44 8

(S)FTP Log File Autoload Nemo Analyze enables loading log files and autonomous rep files to the database automatically over FTP or SFTP connection. The feature is mainly targeted for Nemo Analyze Enterprise, but it can be enabled also in Nemo Analyze Standalone. Loading of the files over FTP is two-step process. First the files are retrieved from the FTP server and saved to a local folder. Then the files are loaded from the local folder into the database.

♦ Please note that the measurements files are removed from the FTP server´s autoload folder after loading. You can configure automatic measurement loading from an FTP server on the FTP Autoload page in the Nemo Analyze Server tool. Nemo Analyze Server can periodically connect to a remote FTP server and load any measurements from the FTP server to the server's database.

Enable FTP autoload, when selected, enables automatic FTP loading can be enabled. Protocol enables you to select between FTP and SFTP protocols. For FTP protocol, the Use active mode option can be used to select either passive or active FTP connection. For SFTP the Use active mode option is not available. Host, Port, Username and Password define the address and login information of the remote server. Remote folder defines the folder on the server from where Nemo Analyze Server will search for the measurement files to load. Nemo Analyze Server can search for measurements in more than one folder on the server. To add more folders, enter them into the Additional folders field separated by vertical line ( | ) characters.

44 9

Scanning interval defines how often Nemo Analyze Server will connect to the FTP server and search for newly-added measurements. Enter the value in seconds. To also scan subfolders, select Load files recursively from subfolders. When selecting Delete files from server after load option, all downloaded files are automatically deleted from the server. Apply changes by clicking Apply Changes at the bottom of the page.

O T HER T A S K S

45 0

OTHER TASKS EDITING COLOR SETS Color sets are used to color the measurement route and BTS icons on a map based on parameter values. This makes it easier to spot problem areas on a map. Color sets can also be used in grid and numerical data views to highlight certain data. To edit and create color sets, select Tools | Color set editor. In the Color Set Editor dialog you will see a list of all existing color sets. You can sort the color sets by selecting the Type and Group. You can also search for a color set by its name. To edit an existing color set, double-click on the color set.

O T HER T A S K S

45 1

In the Color Set Properties dialog you can edit the settings for each color set. Click Modify.

Name and Short Name identify the color set. Select from the Groups list the items with which the color set will be associated. Type defines what kind of data the color set is used with, numerical, gradient, or string. The Groups and Type settings can be used to sort the color sets in the Color Set Editor dialog. Values table displays the different value ranges and the colors associated with them.

Importing Color Sets It is possible to import color sets from Nemo Analyze 4.0 and Nemo Outdoor. Select File | Import | Old Color Sets. In the Open dialog, browse the color set file (.csf) you want to import and click Open. In the Import Color Sets dialog, select the color sets that you would like to import and finally click OK.

The imported color sets are added in the Color Set Editor.

O T HER T A S K S

45 2

Automatic Generation of Color Sets With Nemo Analyze it is also possible to generate color sets automatically from parameter values that appear in the measurement file. First go to the Maps page in the Workspace by clicking the icon, and open a blank map.

On the Measurements page in the Workspace, click on a measurement file. From the Parameters view, select a parameter that you want to plot on the map, for example, RX level full, and drag it on the map. A route is drawn on the map and it is colored by default by using color rotation.

O T HER T A S K S

Right-click on the map and select Generate Color Set from the popup menu.

45 3

O T HER T A S K S

45 4

In the Color Set Wizard, select the parameter that you dragged on the map, e.g., RX level full. In the Column field, select the parameter again. Click Next.

Type a name and a short name for the new color set. Also define in which group the color set will be added. Finally, click Finish. The new color set is generated.

O T HER T A S K S

45 5

To apply the new color set on the route, right-click on the route and select Properties. In the Color page, select Based on value as Mode and then the color set you created (e.g., RX level full 2(dBm)) and the corresponding parameter in the Scheme field (e.g., RX level full). Click OK.

The color set is applied to the route. The color legend on the right displays the colors and the corresponding values.

O T HER T A S K S

45 6

O T HER T A S K S

45 7

Use Case 23.: Automatic Generation of Color Set for a Value Range This use case explains how to generate a color set automatically for a value range. This functionality is particularly useful when creating color sets for, e.g. scrambling code, cell id, and BSIC. First open a blank map from the Maps page in the Workspace by double-clicking on a map in the Loaded view. It is assumed that the map has been loaded to the Workspace from the Map Folder.

O T HER T A S K S

45 8

Next, select a measurement file from the Workspace. From the Parameters view, select a parameter that you want to plot on the map, for example, Cell identification, and drag it on the map.

O T HER T A S K S

45 9

A route is drawn on the map. The route is colored by default by using color rotation. If the route appears as symbols, right-click on the route, select Properties, and on the Route page select Line in the Draw Mode field. Click OK.

Next, right- click on the Color Legend in the side panel and click on Edit Selected. In the Color Set Properties dialogue click Add Range.

O T HER T A S K S

46 0

In the Add Range dialogue, you can define a value range for a new color set, and the interval between the values. Here the value range is from 116731 to 117419 with an interval of 1. Click OK.

The new value range for the color set has been created. Now the various parameter values show more distinctly on the map due to the user-defined value range.

O T HER T A S K S

46 1

Use Case 24.: Creating a Color Set This use case describes the steps for creating a new color set. Select Tools | Color set editor. In the Color Set Editor, click the Add button.

An empty Color Set Properties dialog opens up. Define first the settings at the top of the dialog. Next start defining the value ranges and colors. Click the Add button.

In the Range Properties dialog, select the color and then the upper and lower limits of the value range. You can also write a description for the value range. Finally click OK.

O T HER T A S K S

46 2

O T HER T A S K S

46 3

Repeat the step until you have a complete set of values. Click OK and the new color set is added to the Color Set Editor dialog.

Use Case 25.: Creating and Applying a Color Set on Map This use case describes the steps for creating and applying a color set on a map. Select Tools | Color set editor. In the Color Set Editor, click the Add button. An empty Color Set Properties dialog opens up. Type a name for the color set, and select in which group it is added. Select gradient as the type. Click the Add button.

Next define the string that will be colored. In the Value Properties dialog, select a color and then the minimum value for the parameter. You can also write a description for the value. Finally click OK. Repeat the step for the maximum value.

O T HER T A S K S

46 4

♦ Note that you should always define the values from lowest to highest. Otherwise the color set will not work properly.

The defined values and colors are displayed in the Color Set Properties dialog.

O T HER T A S K S

46 5

Click OK and the new color set is added to the Color Set Editor dialog. Click Close.

Open a blank map, e.g. from the Maps page in the Workspace, and on the Measurements page of the Workspace, select a measurement in the workspace. Type in Ec/N0 best active set in the Parameters view filter field, and drag the parameter on the map. The measurement route appears on the map if the file contains location data.

Right-click on the route and select Properties.

O T HER T A S K S

46 6

In the Properties dialog, go to the Color page and select Based on value as the Mode. In the Scheme field, select Ec/N0 best active set and in the Color set field, select the EcNo gradient color set that was created earlier. Click OK.

The route will be colored based on the set of rules defined in the new color set.

O T HER T A S K S

46 7

Use Case 26.: Creating and Applying a Color Set in Grid This use case describes the steps for creating and applying a color set in a grid. Select Tools | Color set editor. In the Color Set Editor, click the Add button. An empty Color Set Properties dialog opens up. Type a name for the color set, and select in which group it is added. Make sure that the name of the new color set is not already in use. Select string as the Type. Click the Add button.

O T HER T A S K S

46 8

Next define the string that will be colored. In the String Properties dialog, type in the string of text that will be colored and select the color used. You can also write a description for the string.

Click OK.

The new string is displayed in the Values field of the Color Set Properties dialog.

Click OK and the new color set is added to the Color Set Editor dialog.

O T HER T A S K S

46 9

Open a Layer3 signaling grid. Select a device in the Workspace, and type L3 in the Parameters view filter field. Right-click the L3 signaling parameter, and select Open in | Grid. A workbook containing L3 signaling data in a grid is opened.

O T HER T A S K S

47 0

Right-click on the grid, and select Properties. From the Color Sets tab of the Properties dialog, select the column Message Name and from the drop-down menu the previously created color set and click OK.

O T HER T A S K S

The signaling messages defined in the color set are colored.

47 1

O T HER T A S K S

SCHEDULING EVENTS The Event Scheduler makes it possible to schedule workbooks and reports to be run and measurement files to be loaded to the database automatically from a predefined folder. To open Event Scheduler, select Tools | Event Scheduler from the Ribbonbar.

The Scheduler view opens.

47 2

O T HER T A S K S

47 3

To add an event, select a timeslot from the calendar, right-click over it, and select Add Event from the popup menu.

The Schedule Event Batch dialog opens.

One event batch can contain several events that are being run successively. • •

Batch name defines a name for the batch. Start time defines a start time for the batch.

O T HER T A S K S

• •

• • • • • • •

47 4

To define a recurring batch, click the Recurrence button. For more information on recurring events, see Defining Recurring Events on page 484. Measurement folder defines the folder that is used as source for the events in this batch. Reports run by the events are run for measurements in this folder. Update folder before report execution, if selected, ensures that the folder has been refreshed before execution of the event batch. Do not run event for empty folder, if selected, ensures that a report is not generated if the folder where the report should be generated is empty. Export folder defines a destination folder for the exported report. Autogenerate name generates a filename for the exported file automatically. When report ready defines whether report/workbook will be closed and if an automatic notification email to be sent upon scheduled report execution. Attach report, if selected, automatically attaches scheduled reports to event reporting emails. Configure email allows you to define notification email settings.

Add… enables you to add events through the Schedule Event dialog.



Event name defines a name for the event.



Event type defines the event as a report event, a workbook event, a load folder event, or as a KPI threshold alarm event. To create and define an event of the selected type, click the Configure button.

Delete enables you to delete an event. Up enables you to move an event up in the batch. Down enables you to move an event down in the batch.

O T HER T A S K S

47 5

Report Events Selecting Run Report as the Event Type in the Schedule Event dialog opens the Configure Report dialog.

Measurement folder defines the folder on which the report will be run. Update folder before report execution, if selected, checks whether there are new measurement files in the folder before running the report. Do not run event for empty folder, if selected, ensures that a report is not generated if the folder where the report should be generated is empty. Report per measurement, if selected, runs the report on each measurement file separately. Report file defines the report that is to be run on the measurement files within the folder defined in Measurement folder. To browse for a report file, click the browse button, select a report file and click OK. Export, if selected, enables automatic export of scheduled reports to PDF, MS Excel, MS Word, Rich text, text, and HTML. Export folder defines a destination folder for the exported report. Autogenerate name generates a filename for the exported file automatically. Additional Report Scope Settings opens the Report Scope dialog. Close workbook when report ready, if selected, automatically closes the workbook after export. Send email when report ready defines an automatic notification email to be sent upon scheduled report execution.

O T HER T A S K S

47 6

Attach report, if selected, automatically attaches scheduled reports to event reporting emails. Configure email allows you to define notification email settings. Clicking the Configure email button in the Configure Report dialog opens the Email dialog.

To defines the recipient email address. Subject displays the default subject line of the notification email. Message allows you to edit the automatic notification email. Clicking the Additional Report Scope Settings button in the Configure Report dialog opens the System tab of the Report Scope dialog.

System defines the systems that will be included in the report. Band defines the bandwidths that will be included in the report.

O T HER T A S K S

47 7

To define the scope of the report based on time or area, select the Time & Area tab.

Begin time defines the start time for the time range from which the measurement files will be processed. End time defines the end time for the time range from which the measurement files will be processed. Area, if selected, includes enables the limiting of the report scope based on area. Define Area opens the Select Polygon Area dialog. Clicking the Define Area button on the Time & Area tab of the Report Scope dialog opens the Select Polygon Area dialog.

O T HER T A S K S

47 8

Select a map in the Filename field, or load one through the browse button. Next, define an area on the map using the left mouse button. The Save As button enables you to save the map with the selected area for later use. Click OK.

O T HER T A S K S

47 9

Workbook Events Selecting Run Workbook as the Event Type in the Schedule Event dialog opens the Configure Workbook dialog.

Measurement folder defines the folder on which the report will be run. Update folder before report execution, if selected, checks whether there are new measurement files in the folder before running the report. Do not run event for empty folder, if selected, ensures that a report is not generated if the folder where the report should be generated is empty. Report per measurement, if selected, runs the report on each measurement file separately. Workbook defines the workbook that is to be run on the measurement files within the folder defined in Measurement folder. To browse for a workbook file, click the browse button, select a workbook file and click OK. Export to defines whether the workbook is to be exported as image files (image per page) or as a PDF document. Export folder defines a destination folder for the exported workbook. Autogenerate name, if selected, generates a filename for the exported file automatically. Export name defines the name of the exported report. Close workbook when report ready, if selected, automatically closes the workbook after export.

O T HER T A S K S

48 0

Send email when workbook ready defines an automatic notification email to be sent upon scheduled workbook execution. Attach report, if selected, automatically attaches scheduled reports to event reporting emails. Configure email allows you to define notification email settings. Clicking the Configure email button in the Configure Workbook dialog opens the Email dialog.

To defines the recipient email address. Subject displays the default subject line of the automatic notification email. Message allows you to edit the automatic notification email.

Load Folder Events Selecting Load Folder Event as the Event Type in the Schedule Event dialog opens the Configure Folder dialog.

Load folder defines the folder from which all measurement, map, BTS, report, etc. files are loaded. Include subfolders, if selected, causes all measurement, map, BTS, report, etc. files to be loaded from all subdirectories of the folder defined in Load folder.

O T HER T A S K S

48 1

KPI Threshold Alarm Events Selecting KPI Threshold Alarm as the Event Type in the Schedule Event dialog opens the Configure KPI Threshold Alarm dialog.

Measurement folder defines the measurement folder on which the KPI is run. Update folder before report execution, if selected, checks whether there are new measurement files in the folder before running the report. Do not run event for empty folder, if selected, ensures that a report is not generated if the folder where the report should be generated is empty. If the Check threshold for each measurement in folder option is selected, the threshold will be executed per file separately, instead of running the threshold test over all the log files in the selected folder. Report per measurement, if selected, runs the report on each measurement file separately. KPI threshold allows you to define the threshold condition. Run script, when selected, allows you to set any script (.bat) to be run when the threshold condition is fulfilled. Send email, when selected, allows you to configure an email notification to be sent when the threshold condition is fulfilled. Clicking the Add below the KPI thresholds box in the Configure KPI Threshold Alarm dialog opens the Analyze Wizard – Measurement Parameters dialog.

O T HER T A S K S

48 2

Select a parameter from the Parameters view and click Next. The Analyze Wizard – Filters dialog opens.

The dialog allows you to define optional filters by clicking the Add button. It is also possible to set multiple KPI triggers with AND/OR elements. After defining optional filters, click Finish.

O T HER T A S K S

48 3

Clicking the Configure email button in the Configure KPI Threshold Alarm dialog opens the Email dialog.

To defines the recipient email address. Subject displays the default subject line of the automatic notification email. Message allows you to edit the automatic notification email.

O T HER T A S K S

48 4

Defining Recurring Events Clicking the Recurrence button in the Schedule Event Batch dialog opens the Event Recurrence dialog.

Event time allows you to define a Start and End time (i.e. duration) for the event. Recurrence pattern allows you to define how often the event recurs, i.e. Daily, Weekly, Monthly, or every N week(s) on [weekday(s)]. Range of recurrence allows you to define duration for the recurrence pattern, either based on Start and End by dates, or based on a user-defined number of occurrences using the End after N occurrences control.

O T HER T A S K S

48 5

TASK MANAGER AND PROBLEM REPOSITORY The Task Manager and the Problem Repository allow the users of Nemo Analyze Enterprise Edition to store reports on detected network problems into the server database. A problem report may contain screenshots and free-form description of the problem, as well as references to the log file(s) displaying the problem. Other users of the client/server system can view the problem report and drill down to the relevant log files to analyze the problem. To add a problem to the repository as an open task, right-click in the data view displaying the problem at problem spot (i.e. the point in time where the problem is apparent) and select Add task from the popup menu. The Task Configuration dialog of the Task Manager opens (see Configuring and Editing a Task).

To access the Task Manager without adding a task (e.g. to manage, edit, and delete existing tasks), move your mouse over the Task Manager tab on the right side of the screen to open the Task Manager view. If the Task Manager tab is not visible, enable the Task Manager by selecting View | Panels | Task Manager. The Task Manager view displays a control that allows you to open four different task views: tasks assigned to you (My tasks), all existing tasks (All tasks), open tasks assigned to you (My open tasks), and closed tasks that have been assigned to you (My closed tasks). Select and open a view by double-clicking on the view type (see Managing Tasks).

O T HER T A S K S

48 6

Configuring and Editing a Task When a new task is created, or an existing one is opened for editing, the Task Configuration dialog opens.

Title defines the task name. Assigned to allows the task to be assigned to a specific user. Status defines the status of the task as Open or Closed, or as any user-defined status entered into the field. Priority defines the priority of the task as 1 (high), 2 or 3 (low). Due date defines a due date for finishing the task. Created by displays the name of the user who created the task. Task id displays the automatically created unique task identification number. Category allows the task to be assigned with a user-defined category (e.g. classification according to the problem type). Timestamp displays the point in time when the problem occurred. Longitude displays the geographical location of the problem’s occurrence in longitude. Latitude displays the geographical location of the problem’s occurrence in latitude. Cell name allows the cell that was active at the time of the problem to be selected. Area allows the user to enter the placename or a textual description of the area where the problem occurred.

O T HER T A S K S

48 7

Details allows the user to enter a textual description of the problem.

The Attachments tab of the Task Configuration dialog allows you to add attachments to the task.

Add allows you to add an attachment to the task. Delete allows you to delete existing attachments. Save allows you to save the selected attachment to the hard drive. Execute allows you to open or run the selected attachment.

O T HER T A S K S

48 8

The Location tab of the Task Configuration dialog opens

The Location tab displays the reported location of the problem’s occurrence on map based on the Longitude and Latitude defined on the Problem Details tab. The map can be selected using the drop-down menu immediately above the map.

O T HER T A S K S

The Preview tab displays a screen capture of the data view when the task was created.

48 9

O T HER T A S K S

49 0

MANAGING WORKSPACE WITH PROJECTS Project manager helps to focus on the subset of your data. To open Project manager, select File | Project Manager from the Ribbonbar.

To add project, right-click on the Add button. The Add Project dialog appears. Define a name for the project and select OK. The project will appear in the Project drop-down menu. To remove or rename the project, click on the Remove or Rename button.

By clicking the Add button, you are able to add folders, measurements, BTS files, maps, reports and workbooks to the project.

O T HER T A S K S

49 1

To open a project you have created, select View and click on the arrow next to the Project manager button to display a list of all projects and select the project you want to open. If you select No Project Nemo Analyze will stop using the Project Manager feature and it will display all measurements and other items in the UI. Note that when No Project is selected, it is not possible to modify project contents using the Project Manager,

MANAGING USERS AND USER GROUPS The User manager enables you to manage users and user groups (Nemo Analyze Enterprise Edition). To open User manager, select Tools | User manager from the Ribbonbar.

O T HER T A S K S

49 2

To create a new user, select the folder Users in Database Management | Users and Groups from the directory tree, right-click on the empty background of the Name field on the right of the directory tree, and select New User… from the popup menu.

The New User dialog opens.

Name defines the user name. Password defines the password for the user account. To set a new password for a user, right-click on the user in the Name field, and select Set Password from the popup menu.

The Set Password dialog opens.

O T HER T A S K S

49 3

Type a new password in the Password field and click OK. To delete a user, right-click on the user in the Name field, and select Delete from the popup menu.

User Groups The available user groups include Administrators, Users, Power Users, Autonomous Users, and Autonomous Managers. Administrators have unrestricted rights, including access to the cleanup function. Users do not have delete rights and are only allowed to make queries and load files into the database. Users are allowed to view all data and alter minor elements of a file, e.g. configure notifications. Power Users have delete rights, i.e. they are allowed to delete measurement and BTS files. Otherwise the rights of the Power Users are identical to those of the Users. Autonomous users have right to view all history and measurements of Nemo Handy-A Autonomous units loaded into the system, Autonomous users do not have right to issue configurations, that is, to order Nemo Handy-A Autonomous units to do measurements. Automomous managers have full rights to all Nemo Handy-A Autonomous units loaded to the system, including right to view history and logfiles produced by the units, as well as managing the measurements to be done. Nemo Handy-A Autonomous unit groups created from the Fleet Manager are also shown in the User groups. Dallas units in the picture below is an example of such a group. Users added as members of that group get right to tissue configurations (order measurements) to the Nemo Handy-A Autonomous units allocated to that group. As a prerequisite, such users have to be also members of Autonomous users group. This means such users will be able to see all the Nemo Handy-A Autonomous units in the system, but can only issue configurations for selected subset of the Nemo Handy-A Autonomous units as defined by the Autonomous unit group.

O T HER T A S K S

49 4

To add users to a group, select the folder Groups in Database Management | Users and Groups from the directory tree, right-click on a user group on the right of the directory tree (e.g. Power Users), and select Add to Group… from the popup menu.

The Group Properties dialog opens.

To add a user to the group, click Add. The Select Users dialog opens.

O T HER T A S K S

Select the user(s) you want to add. To select multiple users, hold the Control key down while selecting the users. Click OK. The Group Properties dialog opens, displaying the group members.

To remove users from the group, select a user and click the Remove button.

49 5

O T HER T A S K S

49 6

VIEWING SERVER STATISTICS To access server statistics (Nemo Analyze Enterprise Edition), select Tools | Server statistics from the Ribbonbar.

Server statistics are displayed.

To refresh the statistics, right-click on the statistics view and select Refresh from the popup menu. To enable automatic statistics updates (updated every 5 seconds), right-click on the statistics view and select Poll from the popup menu.

O T HER T A S K S

49 7

Managing Tasks To access the Task Manager (e.g. to manage, edit, and delete existing tasks), move your mouse over the Task Manager tab on the right side of the screen to open the Task Manager view. If the Task Manager tab is not visible, enable the Task Manager by selecting View | Panels | Task Manager.

The Task Manager view displays a control that allows you to open four different task views: tasks assigned to you (My tasks), all existing tasks (All tasks), open tasks assigned to you (My open tasks), and closed tasks that have been assigned to you (My closed tasks). Select and open a view by double-clicking on the view type.

The selected task view type (e.g. My open tasks) opens with all tasks of the selected type listed.

O T HER T A S K S

49 8

The map view below the task list displays all tasks of the selected type, e.g. All tasks, My open tasks, etc. The displayed map may be selected using the drop-down menu immediately above the map.

Right-clicking on the task list opens a popup menu.

Configure Task allows you to edit the selected task. Add Task allows you to create a new task. Delete Task allows you to delete the selected task. Refresh allows you to refresh the task list.

O T HER T A S K S

49 9

EDITING OPERATOR SETTINGS Select Tools | Operators | Operators from the ribbonbar to manage operator settings. These settings are used as the basis of operations such as statistics per operator.

The Mobile Operator list is displayed. To edit the properties of an operator or to add a new operator to the list, right-click on the operator, and select Modify or Add from the popup menu.

O T HER T A S K S

The Operator Configuration dialog opens.

Operator name defines the operator name. Mobile country code defines the operator’s MCC. Mobile network code defines the operator’s MNC.

50 0

O T HER T A S K S

50 1

EDITING CDMA OPERATOR SETTINGS Select Tools | Operators | Operators from the ribbonbar to manage CDMA operator settings. These settings are used as the basis of operations such as statistics per operator.

The CDMA Mobile Operator list is displayed. To edit the properties of an operator or to add a new operator to the list, right-click on the operator, and select Modify or Add from the popup menu.

The Operator Configuration dialog opens.

Operator name defines the operator name.

O T HER T A S K S

Sid defines the system identification number.

50 2

O T HER T A S K S

50 3

CONFIGURING NOTIFICATION ICONS Nemo Analyze allows you to configure notification icons for all measurement events. These icons can be displayed in graphs and maps to alert you when something interesting happens. See viewing notification icons in maps and viewing notification icons in graphs. The notification icons can be configured using the Parameters view. Alternatively, notifications can also be configured using the Notification Configuration functionality.

Configuring Notifications Using the Parameters view The parameter-specific notification icons are displayed in connection with the relevant parameter (e.g. with the parameter Call connected) in the Parameters view. The parameters that have not been assigned with a notification icon are indicated by the icon. To change the default icon of a parameter, right-click on the parameter and select Change Defaults from the popup menu.

The Change Defaults dialog opens.

O T HER T A S K S

50 4

To select a new notification icon, click the browse (…) button. The Open dialog opens. Select the new notification icon and click the Open button. The Image field of the Change Defaults dialog now displays the directory path of the selected icon.

Click OK to set the selected icon as the default notification icon for the parameter. The icon is displayed in the Parameters view in connection with the parameter.

O T HER T A S K S

50 5

Notification Configuration You can access the Notification Configuration tool by selecting Tools | Notificatios. In the Notification Configuration dialog you can define icons for all measurement events. These icons can be displayed on graphs and maps to alert you when something interesting happens. See viewing notification icons on maps and viewing notification icons on graphs. There are a number of default notifications for you to choose from but you can also modify the default notifications or make new ones. Select a notification from the list and click the Modify button.

In the Notification Properties dialog, browse a new bitmap in the Icon field and click OK.

O T HER T A S K S

50 6

MENU EDITOR With the Menu Editor you can add workbooks to the Workspace menus and edit the groups in which queries and workbooks are organized. These groups are visible, for example, in the workspace when you right-click on a device. You can open the Menu Editor by selecting File | Menu editor, or by right-clicking on a folder in the Workspace and selecting Customize Menu. To edit groups, first select a group from the Groups section in the Menu Editor dialog. These are the group labels that are visible in the user interface. Under Menus, select the workbooks are shown in the group menu. For each group you can select from the right-hand side in the Menu Editor dialog the cellular systems for which the particular group is available. For example, if you have a file measured in the TETRA network, you do not necessarily need to see the UMTS or CDMA groups. To add a new workbook, click Add and select a workbook from the Workbooks dialog. Click OK.

O T HER T A S K S

The workbook will appear in the Menu Editor and in the selected menu.

Rename workbooks by right-clicking on a workbook in the Menu Editor and selecting Rename workbook.

50 7

O T HER T A S K S

50 8

You can add workbooks to three different menus in the Workspace: Device, Folder, and Measurement menus.

The Device menu is the popup menu that opens when you rightclick on a device. It contains items, such as, Correlate Parameters and Network Parameters.

The Folder menu is the popup menu that opens when you rightclick on a file folder under the Measurements folder.

O T HER T A S K S

50 9

The Measurement menu is the popup menu that opens when you right-click on a measurement file. It contains items, such as, Timeline and Adjust Coordinates.

O T HER T A S K S

51 0

CONFIGURING SYSTEM SETTINGS In the Options dialog you can make some general system settings. Select View | Options to open the dialog.

Options – Environment

Hide advanced UI features hides and displays advanced features that are not needed in basic use. Hide advanced SQL functionality hides and displays advanced SQL features that are not needed in basic use. Display web content using Internet Explorer, when selected, enables displaying HTML files in the Nemo Analyze workbooks. When the Maintain workspace state when application is closed and restarted option is selected, also items in the workspace that are not in the database, i.e., maps and reports, are loaded when you start Nemo Analyze. When the Clear query clipboard when application is closed option is selected, the Query Clipboard is emptied when you exit Nemo Analyze. When a number of minutes is entered into the Auto-save default workspace every X minutes field, all open workbooks are auto-saved as the default workspace on regular intervals. This prevents loss of work, e.g. in the event of a system crash, as the latest auto-saved workbooks are always automatically reopened in the program startup. To prevent the default workspace from opening during startup, hold down the Shift key. JPEG compression quality defines the quality of images exported from Nemo Analyze. You can save workbooks as images by selecting Edit | Send as Image to.

O T HER T A S K S

51 1

Image to clipboard fixed size enables you to define a fixed size for pictures placed on the Clipboard.

Default paths defines the default locations of different types of files. Nemo Analyze will automatically look for the defined file types in these folders.

Proxy defines the proxy server, username and password. This setting may be needed when using Live maps.

O T HER T A S K S

51 2

Throughput defines the unit of measure for throughputs Base station identification code defines the number format for base station identification codes. Cell identification defines in which mode the parameters are presented. Distance defines the unit of measure for distance. Velocity defines the unit of measure for velocity. Hide date from timestamps option hides and displays the date in timestamps. Limit number of decimal digits in UI to defines the maximum number of decimal digits displayed.

O T HER T A S K S

51 3

Statistics enables you to specify a default basis for statistics calculations (i.e. whether the calculations are based on Time, Distance, or Sample), whether Nemo Analyze should ask you to select the basis each time a calculation is performed and whether the dB-parameter statistics are calculated using linear math.

Header title is displayed at the top of the page when you print views from Nemo Analyze.

O T HER T A S K S

Server defines the SMTP server IP address. Port defines the SMTP port. Username defines the SMTP server username. Password defines the SMTP server password. From defines the sender email address. To defines the recipient email address for notification emails sent by the event scheduler. When Use SSL is selected, emails are sent using an encrypted connection.

51 4

O T HER T A S K S

51 5

Options – Database

The Server control enables you to switch between different database configurations and databases (e.g. between the standalone database and the database server). It also enables you to Add, Delete, and Modify configurations. Analyze-Local is the default standalone database of Nemo Analyze. Modify opens the Add Server dialog with existing database settings, enabling you to modify an existing database configuration. Add opens the Add Server dialog, enabling you to define a new database configuration. The Additional data sources control enables you to configure connections to other ODBC databases on your computer. It enables you to Add, Delete, and Modify configurations.

O T HER T A S K S

51 6

Title defines the title of the server. Server host defines the server’s IP address. ODBC port defines the ODBC port. Server port defines the server port. By default, Nemo Analyze uses the server port 12001. User defines the username. Password defines the password.

Name selects the data source. User defines the username. Password defines the password.

Auto-hide columns from queries option hides query data that is not relevant. When the Enable query memory usage warning option is selected, Nemo Analyze will warn you when the query memory usage exceeds the Threshold value limit.

O T HER T A S K S

51 7

When selected, Allow queries to be run in parallel allows you to enable queries to be run in parallel and select the maximum amount of parallel queries. Use Analytics to preprocess measurement data, when selected, enables Nemo Analyze to preprocess the measurement data, allowing instant event queries from large datasets. Allow overlapping when joining measurements, when selected, enables Nemo Analyze to join files even if they are overlapping in time. This feature may be needed when processing TEMS log files that have been cut to multiple adjacent log files during the measurement. Even though they are adjacent, there might be an overlap of a few seconds between consecutive log files that will prevent joining the files if this option is not selected.

Add description to loaded, when set to Prompt user or Project name, automatically adds or prompts the user to add a description to a new measurement file when it is loaded to the database. This feature is useful if the description field is used to filter or categorize log files later on in post processing. Auto rename duplicate file names, when selected, automatically renames a file if the filename is the same as of an existing filename in the database.

O T HER T A S K S

51 8

Options – Report

When the Open HTTP links in external browser option is selected, web pages are opened in a browser window. Otherwise they are opened in Nemo Analyze.

Snapshot settings define the Nemo Analyze Snapshot server name.

O T HER T A S K S

51 9

Options – Color

The Palette is used, for example, to determine colors for neighbor-style graphs and routes.

The Color Legend dialog enables you to set statistics to be calculated based on time, distance, or samples.

O T HER T A S K S

52 0

Options – Graph

When the Smooth scrolling when synchronizing option is selected, the graph view will scroll smoothly instead of displaying a part of the measurement and then jumping forward as the synchronization marker moves out of view. Palette defines the color palette style for graphs. Sort bar graph by parameter enables you to group bars in bar graphs by parameter rather than by x axis values. For more information, see Group Values.

O T HER T A S K S

52 1

Options – Map

Open all workbooks with (Default/MapX/Live Map) defines which map type is used when opening workbooks. Default map type defines the map that is opened by default when no other map file is available. When the Automatically zoom to first added layer option is selected, Nemo Analyze will zoom in on the map layer that is added first. Print ratio defined the print ratio in percentage.

O T HER T A S K S

52 2

Draw defines how the route is drawn (line/symbol/image/image & background). When the Automatically offset simultaneous measurement routes on the map option is selected, an offset is automatically added to measurement routes that overlap each other, as is the case, for example, with multi measurements. You can define the default offset in x and y directions. When the Automatically add default BTS for measurement route option is selected, Nemo Analyze will check from the file header what BTS file was used when the file was recorded and open the same file if it is loaded in the database. With the Hide distance lines longer than X km option you are able to hide unusually long lines which probably signify a problem with the GPS connection. When the Hide default color line option is selected the route is hidden from the map when the route line has no color based on the current color set. Default route thickness enables you to define the default thicknesses of high band and low band routes.

O T HER T A S K S

52 3

When the Automatically add default map to empty map control option is selected, the default map is opened automatically if you open an empty map view. When the Use default map in workbooks option is selected, all workbooks use the map defined in Default map instead of their own default maps.

Default location defines the default location when using the live map functionality.

O T HER T A S K S

52 4

Default map defines which map type is used by default Map service defines which map service is used. See Viewing on Live Map.

Options – BTS

BTS texts options allows you to define the size and style of BTS text. Display BTS overlay on top of other layers sets BTS layers to be displayed over all other layers. Default BTS filter and Carrier allows you to define the default BTS filter and carrier.

O T HER T A S K S

52 5

Cell size defines the size of the BTS cell icon in pixels. Fixed defines the fixed size of BTS cells in pixels. Dynamic, max size defines a maximum size for dynamic BTS cell icons (i.e. icons which change size based on zoom level). Show site names option hides and displays the site names. Draw frame hides and displays the outlines of BTS icons. Site transparency defines the transparency of the BTS icons.

O T HER T A S K S

52 6

Show cell information option hides and displays the selected cell information. When the Show Cell Information option is selected, by clicking Add you are able to define which cell-specific information element is displayed on the map for each cell. Metric can be set per technology and band.

Hide cell texts on low zoom levels (performance optimization) option hides partly or completely the cell texts when the map is zoomed out so that the map can be drawn faster and with less visual distractions. The level is adjustable with a slider. Zoom levels are specific to used maps. Use cell beam range from BTS file allows you to enable/disable the display of cell beam range based on cell beam range data in the BTS file. Additionally, use estimation from antenna height and tilt estimates the base station coverage area based on antenna height and tilt. Default beam defines the default beam range in meters. Default beam angle defines the default beam angle in degrees. Beam transparency defines the transparency of the beam range layer.

O T HER T A S K S

52 7

Default color defines the default color of the BTS icons. Default beam color defines the default beam color. Default settings for BTS parameter allow you to define default color sets for BTS parameters.

BTS Technology Based Settings enable you to choose the color and the size of the base station depending on which network´s base station it is, or based on the carrier number.

O T HER T A S K S

52 8

When the Use technology based settings (overrides icon size settings) option is selected, you are able to open the Set Technology Setting view by clicking Add. By clicking the Icon color option, the size and the color of the base stations changes on the map. If this option is not selected, only the size of the base station changes.

IMPORTING CUSTOM SETTINGS It is possible to import custom settings (such as custom parameters, workbooks, events, queries, color sets, KPIs, etc.) from other users. Select File | Import | Settings from the Ribbonbar.

The Open dialog appears.

Browse for the settings file (.aex) to be imported and select Open.

EXPORTING CUSTOM SETTINGS It is possible to export custom settings (such as parameters, workbooks, events, queries, color sets, KPIs) to other users. All custom settings are saved in a single .aex file. Select File | Export | Settings from the Ribbonbar.

O T HER T A S K S

52 9

The Save As dialog appears.

Select a destination for the settings file (.aex) and select Save. The Export Settings dialog opens.

Select the settings you want to export and click OK. You can export e.g. database settings, custom queries, color sets, events, etc. It is also possible to do multiple selections and select/deselect groups, e.g. all workbooks, all queries, at once. The settings file (.aex) is saved in the selected location and can be imported to any other Nemo Analyze Standalone/Client using custom settings import (see Importing Custom Settings on page 528).

O T HER T A S K S

53 0

IMPORTING MAPINFO POLYGONS MapInfo® polygons can be used e.g. when defining area-based search folders (see Search Folders on page 41) and when limiting queries to measurement files from particular area(s) (see Filtering Based on Polygon Area on page 103).

To import MapInfo polygons, click the polygons icon at the bottom of the Workspace view, rightclick on the Workspace | Polygons | Regions background, and select Import polygon from the popup menu.

O T HER T A S K S

53 1

The Polygon Import dialog opens.

File defines the MapInfo polygon (.TAB) file to be imported. Click the browse button a MapInfo polygon file.

to browse for

Available features allows you to select the polygon file features you want to import. Clear a feature to prevent it from being imported. Selected features allows you to select the polygon file features you want to import. Clear a feature to prevent it from being imported. To select a feature or a set of features, select it in the Available features field and click the button. To select all available features, select it in the Available features field and click the

button.

The selected feature(s) are displayed in the Selected features field.

Import name allows you to define a new name for the imported polygon. To clear a feature or a set of features, select it in the Selected features field and click the To select all available features, select it in the Selected features field and click the Once all polygons to be imported have been selected, click OK.

button.

button.

O T HER T A S K S

53 2

VIEWING LOG ON SYSTEM PERFORMANCE AND SQL FUNCTIONS To access the Log window, select View | Panels | Log window from the Ribbonbar.

The Log window is displayed on the bottom of the screen.

Show output from allows you to define the functions you wish to see the log on. Log, if selected, displays log on general system performance. SQL, if selected, displays log on SQL queries and database functions. The Clear all

button clears the currently displayed log.

US E R INT ERF A C E

53 3

USER INTERFACE MENUS This chapter describes the contents of the menu bar in Nemo Analyze.

Analyze Menu You can access the Analyze menu by clicking on the Analyze main window.

logo at the top left-hand corner of the

Open enables you to open measurement files, maps, BTS files, report templates and data source files.

Workspace enables you to open, save and close workspace items.

Workbook enables you to save active workbooks and floating windows.

Export to PDF… enables you to export workbooks to PDF, Microsoft Word or Microsoft PowerPoint format. This item is displayed only if you have a workbook open. Print… enables you to preview and print active documents, and change printer and printing options. This item is displayed only if you have a workbook open.

US E R INT ERF A C E

53 4

Recent Workspaces enables you to open saved workspaces that you have used recently. You can close Nemo Analyze by clicking on Exit Application.

File Menu

Open | Measurement enables you to load measurement files, maps, BTS files, report templates, and data source files to the database. Open | Workspace enables you to open saved workspaces. Open | Folder enables you to browse for a folder, the contents of which are to be loaded to the database. Save | Workspace enables you to save workspace files (.aws). Save | Workbook enables you to save workbooks (p. 284) and add workbooks as templates to the Workspace menus. Organize enables you to organize measurement files loaded in the database. Project manager enables you to manage workspace with projects. Menu editor enables you to add workbooks to the Workspace menus. Import enables you to import image files to be used as maps, custom settings files (.aex) , and color set files. Export enables you to export workbooks in PDF format and custom settings files in .aex format. Page image to clipboard enables you to save an active workbook or map as an image. You can either save the image on clipboard to enable pasting to other applications, or save the Image to file in .jpg format. You can also set an Export Ratio (or an export size) for the exported image in percentages or in fixed pixel size. Print enables you to preview and print active documents, and change printer and printing options. You can exit the File menu by double-clicking on it.

US E R INT ERF A C E

53 5

View Menu

Add Data View enables you to create empty workbooks, workbooks with selected empty data views, and floating windows. For adding parameters on empty data views, see Adding Data Views. Options opens a dialog that enables you to make some general system settings. Panels enables you to display and hide the Workspace, Log window, Properties, Window browser, Messenger, Query clipboard, Task Manager, and Database loader views. You can exit the View menu by double-clicking on it.

Tools Menu

KPI workbench makes it possible to create custom KPIs by dragging and dropping parameters, correlations, various operations, filters and sort elements to the Workbench, defining their properties, and connecting them into a logical flow chart. The KPI Workbench is part of the Troubleshooting Toolkit option. Query manager enables you to add and edit queries, query filters, properties, statistics, aliases, and correlation queries. Color set editor enables you to edit and create color sets. Notifications enables you to define icons for all measurement events. Event scheduler enables you to schedule workbooks and reports to be run and measurement files to be loaded into the database automatically from a predefined folder. User manager enables you to manage users and user groups (Nemo Analyze Enterprise Edition). Operators enables you to manage operator settings. These settings are used as the basis of operations such as statistics per operator.

Database Browser can be used to display the table structure of the Nemo Analyze Database and to write and test custom queries. CSV templates enables you to create a new CSV import template.

US E R INT ERF A C E

53 6

Server statistics enables you to view server statistics. Spreadsheet enables you to create spreadsheet report template file. Snapshot enables you to view Snapshot report.

Utilities Menu

Reconnect enables you to reconnect to the database if the connection is lost. Synchronization enables you to play back measurement files. Reset Source button resets the synchronization source. The field after the button displays the current synchronization source. Go to beginning

button jumps to the beginning of the file.

Step backwards

button steps one step backwards in the file.

Play backwards

button plays the file from end to beginning.

Stop

button ends the playback.

Play forward

button plays the file from beginning to end.

Step forward

button steps one step forward in the file.

Go to timestamp button jumps to a particular point in the file if timestamps were inserted when the file was recorded. Counter displays the current point in the file. Playback speed defines how fast the file is played back. Area Binning enables you to define the bin size in horizontal X steps and vertical Y steps. To set the bin in meters, select Bins in meters. Zoom enables you to set zoom to occur synchronously in all graphs and maps. Drill Down enables you to set a time range from which log entries are to be included in a drill-down Before and After a selected event in the measurement data. Global Filters enables you to add and remove global filters applied to all operations performed with Nemo Analyze. For instance, if you are interested only in measurement data from a certain restricted area, you can select this area as a filter using polygon area selection.

Fleet Menu Fleet Manager is an optional component of Nemo Analyze intended for the management of Nemo Autonomous fleet. It will be discussed in further detail in the Nemo Autonomous user manual.

US E R INT ERF A C E

53 7

Google Earth Menu Please note that the Google Earth Menu is only visible when a Google Earth map is open on the workspace.

Refresh enables you to refresh the map. Properties enables you to define map-specific properties Side panel Arrow

enables you to hide and display the side panel on the right-hand side of the grid.

enables you to select items on the map view.

Auto centering enables you to force the map to be always centered on the current location. Draw polygon Generate colorset generates a colorset. Export to KML enables you to export a measurement route from Nemo Analyze map to Google Earth in KML format. Zoom to layers extends zoom to layers. Folder from area creates a folder from an area. Polygon region enables you to specify an area of any shape, and run statistics over that area. The results are displayed in the statistics data view. Area binning enables you to define an area on a map which you can run statistics on in the form of bins. The results are displayed on the map as a new semi-transparent layer. Delta plotting enables you to compare the parameter values of two measurement groups from a same route by defining an area on a map (e.g. a portion of the measurement route). For more information on Delta Plotting, see the topic Use Case 14.: Comparing Two Groups of Measurements from the Same Route on Map. Scale bar option displays a distance scale bar on the map Current position option displays the current position and direction on the map. Optimized drawing improves the performance of the route drawing on the map. However, in rare occasions with some projections it may result in skewed route plot. In such case, deselect this option. Select map: The drop-down menu enables you to change the map type of the active map workbook.

Layout Menu Note: The layout menu is only displayed when a workbook is open in Nemo Analyze. When you close all workbooks, also the layout menu is closed automatically.

US E R INT ERF A C E

53 8

Add | Page enables you to add a new, empty page in a workbook. By clicking Graph, Map, Grid, etc. you can add data views in the active page. For adding parameters on empty data views, see Adding Data Views. Remove | Page enables you to remove an active page from a workbook. Copy | Workbook enables you to create a copy of the active workbook for a selected measurement. Organize item enables you to close all workbooks and floating windows, and organize various workbooks and views in the Nemo Analyze main view.

Help Menu

In the Help menu, you will find access to the online help and also shortcuts to some important documents, such as, a description of the Nemo file format.

SH O RT CUT S

53 9

SHORTCUT KEYS Shortcut keys available in Nemo Analyze:

Command

Shortcut Key

Description

Close

ALT+F4

Closes the program.

Close Window

CTRL+F4

Closes the active window (exc. main window).

New Workbook

CTRL+N

Opens an empty workbook.

Next

CTRL+F6

Activates the next open workbook (in the order of last appearance).

Print

CTRL+P

Prints the current view.

Analyze Tools menu shortcut keys: Command

Shortcut Key

Go to the beginning

CTRL+SHIFT+ LEFT ARROW

Jumps to the beginning of the file.

Step backwards

CTRL+LEFT ARROW

Steps one step backwards in the file.

Play backwards

SHIFT+F5

Plays the file from end to beginning.

Stop

F6

Ends the playback.

Play forwards

F5

Plays the file from beginning to end.

Step forwards

CTRL+RIGHT ARROW

Steps one step forward in the file.

F AQ

54 0

TROUBLESHOOTING SOCKET CLOSED DIALOG APPEARS WHEN OPENING NEMO ANALYZE WITH LAPTOP If you have Virtual Machine program (commonly known as VMware) installed on your laptop, it may not be possible to execute Nemo Analyze properly. This is caused by a conflict between VMware and the HASP dongle used in Nemo Analyze that uses VMware for certain internal processes. In this case, the following dialog appears when executing Nemo Analyze:

It is recommended that VMware is removed from the laptop.

T RO UB L E SH O O T ING

54 1

FAQ Q: How soon are changes in the Nemo File Format implemented to Nemo Analyze? A: Changes in the Nemo File Format are implemented very quickly to Nemo Analyze and there is no need to reload any data in the database. Q: Which database is used in Nemo Analyze? A: Nemo Analyze uses the Object Store database. Q: Which reporting tool is used in Nemo Analyze? A: The Viewer version of Crystal Reports reporting tool is included in the Nemo Analyze package but you can also use other reporting tools. To create new report templates, you will need the Crystal Reports Designer tool or some other SQL-compatible designing tool. Q: I opened a parameter on a map but the samples are shown without color coding? A: If you opened data on the map through the Analyze Wizard (right-click on a device in workspace | Pick Parameter) and selected a map instead of the default view, only the selected parameters or events are displayed. You should first open a map and then drag and drop a measurement file on the map. Then use color sets to highlight parameter values on the route.

NE MO AN A L YZ E S U P PO RT

54 2

NEMO ANALYZE SUPPORT If you have questions on or beyond this documentation, please contact Nemo Analyze technical support. Note that for full support you need to have a valid Maintenance Agreement.

INTERNET SUPPORT AND NEMO USER CLUB The Nemo User Club offers several new ways to benefit from Nemo products. You can find it at our WWW site http://www.anite.com/nemo. Access to the Nemo User Club is restricted to customers with SW maintenance and Technical Support agreements or partner agreements. If you are an existing Nemo customer with SW maintenance and Technical Support agreements, but you are without access to the user club, please complete an on-line registration form. After submitting the requested information, you will receive a personal access key and password by email in a few days time. Once you are registered with our User Club, you will automatically receive e-mails letting you know each time a new version of software for your Nemo Product is released. It is fast, easy, and it is available to you seven days a week, 24 hours a day. If you have questions relating to the Nemo User Club, please e-mail us at [email protected].

PHONE, EMAIL, AND FAX SUPPORT During the warranty period, the phone and fax support related to potential software errors is free of additional charge. Registered users with a valid Maintenance Agreement are entitled to full support. When faxing or emailing, please let us know the number of your Software Maintenance and Support Agreement. Please contact us at the following locations: Europe and Africa Email Tel.

[email protected] +358 50 395 7800

+3318 075 0280 (En français) Americas Email Tel.

[email protected]

APAC Email Tel.

[email protected]

P.R. China Email Tel.

[email protected]

India Email Tel.

[email protected]

+1 469 951 9105 +1 469 774 4608 (En español e português)

+65 6254 9003

+86 10 6567 8528

+91 982 0016372

NE MO AN A L YZ E S U P PO RT

Middle East Email Tel.

54 3

[email protected] +97 155 620 4132

When contacting us for problem reporting, please supply us with the following information: • your Windows® version number (e.g., Windows® XP), see Windows Control Panel | System • your computer brand model (e.g., Dell) • your Nemo Analyze version (e.g., Version Nemo Analyze 6.50), see Help | About Analyze • your description of the problem • whether you were able to repeat the problem • the corresponding measurement results file (as email attachment or on diskette)

APPENDIX 1 MAKING MAPINFO® MAPS Using raster image files, you can bring paper maps, photographs, and other graphic images into MapInfo®. You can scan paper maps and then use paper maps as the foundation for the maps you create in MapInfo®. After scanning the paper map into a raster image file, you can display it in a map window. Nemo Outdoor and Nemo Analyze support only .TIF, .GIF, and .JPG formats. MapInfo® can read the following types of raster images: - filename.TIF - filename.GIF - filename.JPG - filename.PCX - filename.BMP - filename.BIL Color options are: -

Monochrome images: each pixel in map image can be black or white.

-

Gray scale images: each pixel in gray scale image can be black, white, or a shade of gray.

-

Color images: each pixel can be of any color from a palette of available colors. MapInfo® supports 256 colors. When using Nemo Outdoor and Nemo Analyze, we recommend using gray scale images. Doing this, measurement route can be discerned better than with color map images.

Registering a Raster Map If you want to overlay vector data on top of a raster image, then you must register the raster map image so that MapInfo® can position it properly in a Map window. You do this in the Image Registration dialog box. You must identify control point coordinates and projection of the raster image map. It is important to provide accurate control point information when registering a raster map image. Choose control points that can be easily identified and selected, such as street intersections or use the coordinates (latitude and longitude grid) for the selected point from a paper map.



To register a raster map with MapInfo® SW: 1. Choose File | Open Table and Raster Image File Format. Select your raster map image file (.TIF, .GIF, .JPG) and open it. The Image Registration dialog box will be displayed. A preview of the raster map image appears on the screen. 2. Select the Projection button to specify the projection of the raster image map. If you do not know the right projection, the default value is Longitude/ Latitude.

IN DEX

54 5

3. Start adding control points. Click on a location in the preview (raster image map). The Add Control Point dialog box will be displayed showing the location of the point in pixels. Add Map X and Map Y coordinates in decimal formats. For example, to specify the coordinates 65 degrees, 30 minutes, enter 65.5 degrees. Use negative numbers when specifying west and south coordinates. If you want to register a raster map, which does not use longitude and latitude coordinates, specify the appropriate projection in the Image Registration dialog box. Enter your coordinates in the native units of the coordinate system. For example, if you are registering a UTM map image, enter coordinates in meters. Using MapBasic® program, you can convert d/m/s coordinates into decimal format. 4. You must choose at least three control points. Select points that can be easily identified and selected in the map window. 5. After all control points have been defined, click OK in the Image Registration dialog box. The raster map will be displayed in the map window. 6. Move filename.tab and filename.tif/gif/jpg files to the map directory of Nemo Outdoor or Nemo Analyze. 7. Open filename.tab in Nemo Outdoor or Nemo Analyze.

APPENDIX 2 ADDING CSV FILES TO THE DATABASE In addition to files produced with Nemo tools, you can import any character-separated value (CSV) ASCII data into the Nemo Analyze database. The data can be post-processed and visualized using the data views available in Nemo Analyze. Select Tools | CSV templates. The CSV Templates dialog opens.

A P P EN DIX 2

54 7

To create a new CSV import template, select Add. The CSV Import Wizard – CSV Template File dialog opens.

Template file enables you to select a CSV file to serve as a basis for the import template. Click the browse button

to browse for CSV files.

Extension enables you to define the file type the import template will apply to. ♦

Note: It is recommended that the extensions of CSV files with different content structures are renamed to provide each type with a unique extension. For instance, four different types of CSV files, all originally with the extension .csv, could be renamed as .csv1, .csv2, .csv3, and .csv4.

Once Template file and Extension have been defined, click Next. The CSV Import Wizard – CSV Import dialog opens.

A P P EN DIX 2

54 8

Ignore defines the parts of the imported data set that are to be ignored when uploading the data, i.e. the parts that do not contain relevant data. Column row defines the number of top rows to be ignored. Rows allows you to define specific rows to be ignored. Rows starting with allows you to define rows starting with a specific string to be ignored. Columns allows you to divide a CSV data set into columns. Fixed lines defines the content of each column based on the number of characters in a CSV string. For example, the setting 12, 22, 32 defines that the first twelve characters (including spaces) belong to column 1, the next 22 characters to column 2, and the next 32 characters to column 3. Fixed lines should only be used if there are no delimiters in the data set. Delimiter defines the character that separates columns in the CSV data set. You can use one of the default delimiters, i.e. comma, dot, semicolon, , or , or you can define your own delimiter character by entering a character to the Delimiter field. Strip leading and trailing quotation marks removes leading and trailing quotation marks from each column of the imported data set. File preview displays a preview of the CSV file contents. Once the Ignore and Columns settings have been defined, click Next. The CSV Import Wizard – Database Schema Definition dialog opens.

A P P EN DIX 2

54 9

Table name defines the name of the template. Columns enables you to select which columns are included in the imported data set and to define the properties of each column using Column, Column type and Format. Decimal separator defines the decimal separator as comma or dot. Column defines the name of the column selected in the Columns control. Column type defines the data type of the column selected in the Columns control. Keyword allows you to define the content type of columns containing some general data types, such as time and positioning data. Based on these defined content types, the data can be correlated with measurement files of other formats. Format defines the required syntax for the column selected in the Columns control. To define a custom time column syntax element-by-element, click the … button. The Time Format dialog opens. To add syntax elements (e.g. YYYY) and delimiters (e.g. ;), doubleclick the relevant element. Custom syntax is displayed in the Format field of the Time Format dialog.

Data preview displays a preview of the data set structure. Once the properties of each column have been defined, click Finish.

A P P EN DIX 2

55 0

The new template is displayed in the Template field of the CSV Templates dialog.

To open a CSV file using an import template, select Import from the CSV Templates dialog. You can also open a CSV files using an import template by selecting File | Measurement | Open Measurement. The Open dialog opens.

Select a CSV import template (e.g. Template1) by using the Files of type drop-down menu, browse to a folder containing measurement files with the extension defined in the template, select a file, and click Open. For Opening CSV Files from the Database, see below. To export a CSV template, select Export. Then, choose under which name the exported template will be saved as from the file dialog.

A P P EN DIX 2

55 1

Opening CSV Files from the Database All CSV files within the database are displayed on the Measurements page of the Workspace. Files displays all the CSV files stored in the database. Parameters displays all the parameters that are available for the file. The User folder displays userdefined custom parameters. For creating custom queries for CSV files, click here. To open a parameter in its default view, select a CSV file in the Files view and double-click a parameter (e.g. Jerkiness [%]) in the Parameters view. If you want to open the parameter in some other type of view, right-click on a parameter (e.g. Jerkiness [%]) in the Parameters view and select the view type from the popup menu. The Choose Graph Type dialog opens.

Select a graph type. The Select Columns dialog opens.

Define the x and y axes and click OK. The data view opens displaying the selected parameter data on the selected CSV file.

A P P EN DIX 2

55 2

A P P EN DIX 2

55 3

Opening CSV Files without Database Import Optionally, character-separated value (CSV) data can also be opened and viewed in various data views without importing the data into the database. Using this method, the CSV data is loaded only in the workspace. Select File | Open | Measurement | Open Data Source File, and select the file in the Open dialog.

In the Analyze Wizard, you need to define file import parameters. After you have made the settings, click Next and finally Finish. With Skip first you can define how many lines are skipped at the beginning of the file. Delimiter defines how columns in the source file are separated. Columns displays a list of columns detected in the source file. Column type defines the data type of each column. Format defines the data format of each column.

A P P EN DIX 2

55 4

Column aliases define how data is displayed in the data views. You can define a parameter for the axes of each view type.

The imported file is added to the Data Source Files page in the Workspace. You can view the data by right-clicking on the file and selecting Open in Data View.

A P P EN DIX 2

55 5

Creating Custom Queries for CSV Files Correlating and creating custom queries for CSV files is possible using SQL. The Database browser can be used in examining the table structure of the database. To open the Database browser, select Tools | Database browser in the Ribbonbar.

The Database browser view opens. CSV import templates (e.g. Template1) can be found in the folder Views | User.

The CSV import template folder displays both the columns that were imported and some extra columns containing database structure data, such as the_file_title and the_file_extension.

If multiple CSV files have been imported to the database using a particular template, each column in the directory structure will display all rows from the corresponding columns of all the files that match the template. In order to make it possible to identify the file to which each row belongs, the column the_file_title displays the name of the file from which the row was retrieved.

APPENDIX 3 END-USER LICENSE AGREEMENT IMPORTANT - READ CAREFULLY: This End-User License Agreement ("EULA") is a legal agreement between you (either an individual or a single entity) and Anite Finland Ltd for the Anite Finland Ltd software product(s), in whatever form, identified above ("Software Product" or "Software"). The Software Product includes computer software, the associated media, any printed materials, and any "online" or electronic documentation. By installing, copying or otherwise using the Software Product, you agree to be bound by the terms of this EULA. If you do not agree to the terms of this EULA, Anite Finland Ltd is unwilling to license the Software Product to you. In such event, you may not use or copy the Software Product, and you should promptly return the unused product(s) in their original packaging to the place of purchase within thirty days of the date of original purchase. SOFTWARE PRODUCT LICENSE The Software Product is protected by copyright laws and international copyright treaties, as well as other intellectual property laws and treaties. The Software Product is licensed, not sold. 1. GRANT OF LICENSE. This EULA grants you the following rights: Software. You agree that the Software product is licensed to you to be used with the mobile phone(s) and software protection key designated by Anite Finland Ltd for such use ("Designated Hardware"). You also agree that you shall not have more than one copy of the Software Product in use at a time for any Designated Hardware in which the Software Product is to be used or to be distributed except as expressly provided for in this EULA. You may use one copy of the Software Product in binary code form only on one computer at a time in order to conduct system measurements using the Designated Hardware at various locations to the extent necessary for the permitted operation of the application software but may not duplicate the Software Product. Storage/Network/Single Use. You may also store or install a copy of the Software Product in binary code form only over an internal network, and distribute the Software Product to your other computers over an internal network. However, you must acquire and dedicate a license for the Software Product for each Designated Hardware on which the Software Product is used or to which it is distributed. A license for the Software Product may not be shared or used concurrently on different computers. 2. DESCRIPTION OF OTHER RIGHTS AND LIMITATIONS. Limitations on Reverse Engineering, Decompilation and Disassembly. Removal, emulation, or reverse engineering of all or any part of this product or its protection constitutes an unauthorized modification to the product and is specifically prohibited. Nothing in this license statement permits you to derive the source or assembly code of files provided to you in executable or object formats. Limitations on Modifications, Adaptations and Other Changes. You may not modify, adapt or otherwise make any changes to the Software Product except and only to the extent you are expressly permitted to do so under the applicable mandatory law notwithstanding this limitation or by Anite Finland Ltd's prior written consent. Separation of Components. The Software Product is licensed as a single product. Its component parts may not be separated for use on more than one Designated Hardware and computer as designated above.

A P P EN DIX 3

55 8

Not for Resale. This Software Product is “Not for Resale" or "NFR" and your license only permits personal use and you may not sell or otherwise transfer the Software Product for value except as specified below. Rental. You may not rent, lease or lend the Software Product to any person or entity. Software Transfer. You may not otherwise give or permanently transfer any or all of your rights under this EULA without the express prior written consent of Anite Finland Ltd which such consent shall not be unreasonably withheld. Security Mechanisms. Anite Finland and its affiliated companies take all legal steps to eliminate piracy of their software products. In this context, the Software may include a security mechanism that can detect the installation or use of illegal copies of the Software, and collect and transmit data about those illegal copies. Data collected will not include any customer data created with the Software. By using the Software, you consent to such detection and collection of data, as well as its transmission and use if an illegal copy is detected. Anite Finland also reserves the right to use a hardware lock device, license administration software, and/or a license authorization key to control access to the Software. You may not take any steps to avoid or defeat the purpose of any such measures. Use of any Software without any required lock device or authorization key provided by Anite Finland is prohibited. Duration and Termination. This EULA is effective from the day you open the sealed media package or download and continues until termination. You may terminate this EULA at any time. Without prejudice to any other rights, Anite Finland Ltd may terminate this EULA if you fail to comply with the terms and conditions of this EULA. In either event, you must destroy all copies of the Software Product and all associated media, printed materials, updates and component parts and verify to Anite Finland Ltd in writing that such has been done. 3. SUPPORT SERVICES. Anite Finland Ltd may provide you with support services related to the Software Product ("Support Services"). Any supplemental software code provided to you as part of the Support Services shall be considered part of the Software Product and subject to the terms and conditions of this EULA. With respect to technical information you provide to Anite Finland Ltd as part of the Support Services, Anite Finland Ltd may use such information for its business purpose, including for product updates and development. 4. COPYRIGHT AND TRADEMARKS. All title and copyrights in and to the Software Product (including but not limited to any images, photographs, animations, video, audio, music, text and "applets", incorporated into the Software Product), the accompanying printed materials, and any copies of the Software Product, are owned by Anite Finland Ltd or its suppliers. The Software Product is protected by copyright laws and international treaty provisions. You may not copy the printed materials accompanying the Software Product. You may not remove, modify or alter any Anite Finland Ltd copyright or trademark from any part of the Software Product, including but not limited to any such notices contained in the physical and/or electronic media or documentation, in the Anite Finland Ltd Setup Wizard dialogue or 'about' boxes, in any of the runtime resources and/or in any web-presence or web-enabled notices, code or other embodiments originally contained in or dynamically or otherwise created by the Software Product.

A P P EN DIX 3

55 9

The Software Product may include following licenses with related copyrights and titles: WinWAP. Copyright © Winwap Technologies Oy. http://www.winwap.com Perceptual Objective Listening Quality Analysis (POLQA) according to ITU-T Recommendation P. 863 included in this product is protected by copyright and by European, US and other International patents and patent applications and is provided under license from OPTICOM Dipl.-Ing. M. Keyhl GmbH, Erlangen, Germany, 2011 – www.opticom.de POLQA® is a registered trademark of OPTICOM GmbH. Used by permission. © 2011 by the POLQA Coalition of OPTICOM GmbH, Germany - SwissQual AG, Switzerland - KPN, The Netherlands - TNO, The Netherlands. www.polqa.info Further statements shall be incorporated to prohibit additional copying of the POLQA software in whole or in part, other than is essential for the proper operation of the POLQA software or for normal security back-up purposes; prevent the End-User from modifying, translating, reverse-engineering or decompiling the POLQA software except to the extent permitted by law; require that the acknowledgement of the rights in the POLQA software shall not be removed from the POLQA software or any installation of it; Perceptual Evaluation of Speech Quality (PESQ) measurement technology included in this product is protected by copyright and by European, US and other patents and is provided under license from OPTICOM Dipl.-Ing. M. Keyhl GmbH, Erlangen, Germany, 2008 - www.opticom.de For further information please refer to www.pesq.org Further statements shall be incorporated to prohibit additional copying of the PESQ software in whole or in part, other than is essential for the proper operation of the PESQ software or for normal security back-up purposes; prevent the End-User from modifying, translating, reverse-engineering or decompiling the PESQ software except to the extent permitted by law; require that the acknowledgement of the rights in the PESQ software shall not be removed from the PESQ software or any installation of it; Evaluation of Talker Quality (ECHO) measurement technology included in this product is protected by copyright and is provided under license from OPTICOM GmbH, Erlangen, Germany, 2011 - www.opticom.de Further statements shall be incorporated to prohibit additional copying of the ECHO software in whole or in part, other than is essential for the proper operation of the ECHO software or for normal security back-up purposes; prevent the End-User from modifying, translating, reverse-engineering or decompiling the ECHO software except to the extent permitted by law; require that the acknowledgement of the rights in the ECHO software shall not be removed from the ECHO software or any installation of it; Libresample library and libVLC library distributed under LGPL license. For detailed information, see license files located in the software installation directory. Skype is a trade mark of Skype or its related companies. This product/application has not been approved or endorsed by Skype, Skype Communications S.a.r.l. or any of their related companies.

A P P EN DIX 3

56 0

The license management portion of this Licensee Application is based on: SentinelRMS* © 1989-2006 SafeNet, Inc. All rights reserved SentinelRMSe* © 1989-2006 SafeNet, Inc. All rights reserved Iperf copyright. Copyright (c) 1999-2006, The Board of Trustees of the University of Illinois. All Rights Reserved. Permission is hereby granted, free of charge, to any person obtaining a copy of this software (Iperf) and associated documentation files (the "Software"), to deal in the Software without restriction, including without limitation the rights to use, copy, modify, merge, publish, distribute, sublicense, and/or sell copies of the Software, and to permit persons to whom the Software is furnished to do so, subject to the following conditions: Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimers. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimers in the documentation and/or other materials provided with the distribution. Neither the names of the University of Illinois, NCSA, nor the names of its contributors may be used to endorse or promote products derived from this Software without specific prior written permission. THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE CONTIBUTORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE. 5. DUAL-MEDIA SOFTWARE. You may receive the Software Product in more than one medium. Regardless of the type or size of medium you receive, you may use only that one medium that is appropriate for the systems you use to operate the Software Product. You may not use or install the other medium on any system. You may not loan, rent, lease or otherwise transfer the other medium to another user, except as part of the permanent transfer (as provided above) of the Software Product. 6. CONFIDENTIALITY AND NON-DISCLOSURE. You agree to keep in confidence and not to disclose in any manner or form to any third party nor publish any such data or information related to the Software Product. You agree to protect all information and data provided to you by Anite Finland Ltd related to the Software Product with the same degree of care that you use to protect your own like data and information, but with not less than that due care exercised by a reasonably prudent person under the same or similar circumstances. 7. U.S. GOVERNMENTAL RESTRICTED RIGHTS. The Software Product and documentation are provided with Restricted Rights. Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.277-7013 or subparagraphs (c)(1) and (2) of the Commercial Computer Software - Restricted Rights at 48 CFR 52-227-19, as applicable.

A P P EN DIX 3

56 1

8. LIMITED WARRANTY. Anite Finland Ltd warrants that (a) the Software Product will perform substantially in accordance with the accompanying written materials for a period of three (3) months from the date of receipt, and (b) any third party hardware accompanying the Software Products will be free from defects in materials and workmanship under normal use and service for a period of one (1) year from the date of receipt. To the extent that implied warranties are disclaimable, they are disclaimed in paragraph 10. Some states/jurisdictions do not allow disclaimers of or limitations on duration of an implied warranty, so the above limitation may not apply to you. Any implied warranties on the Software Product and, as applicable, third party hardware that is not disclaimable are limited to three (3) months and one (1) year respectively. 9. CUSTOMER REMEDIES. Anite Finland Ltd and its suppliers' entire liability and your exclusive remedy shall be, at Anite Finland Ltd option, either (a) return of the price paid, or (b) repair or replacement of the software or hardware that does not meet the Limited Warranty contained in this EULA and which is returned to Anite Finland Ltd. The Limited Warranty contained herein is void if failure of the software or third party hardware has resulted from accident, abuse, misapplication or events beyond the control of Anite Finland Ltd including, but not limited to Acts of God, acts of nature or acts of war. Any replacement Software Products or hardware will be warranted for the remainder of the original warranty period or thirty (30) days, whichever is longer. Anite Finland Ltd is not responsible for ensuring adequate backup and storage for your data or records. 10. NO OTHER WARRANTIES. To the maximum extent permitted by applicable law, Anite Finland Ltd disclaims all other warranties, either express or implied, including but not limited to implied warranties of merchantability, fitness for a particular purpose, and non-infringement of third-party rights, with regard to the Software Product, the accompanying written materials, and any accompanying hardware. This limited warranty gives you specific legal rights. You may have others which vary from state/jurisdiction to state/jurisdiction. 11. NO LIABILITY FOR CONSEQUENTIAL DAMAGES. To the maximum extent permitted by applicable law, in no event shall Anite Finland Ltd or its suppliers be liable for any damages whatsoever (including without limitation, special, incidental, consequential, punitive or indirect damages for personal injury, loss of business profits, business interruption, loss of business information, or any other pecuniary loss) arising out of the use of or inability to use this Software Product, even if Anite Finland Ltd has been advised of the possibility of such damages. In any case, Anite Finland Ltd and its suppliers' entire liability under any provision of this EULA shall be limited to the amount actually paid by you for the Software Product and/or third party hardware accompanying the Software Product. The Limitations of Liability contained in this Section apply to claims of every kind, whether based on contract law, tort law or otherwise, even if these limitations have the effect of exculpating a party from responsibility for its negligence, fault or other conduct. Because some states/jurisdictions do not allow the exclusion or limitation of liability for consequential or incidental damages, the above limitation may not apply to you.

View more...

Comments

Copyright ©2017 KUPDF Inc.
SUPPORT KUPDF