User name: Admin Password:12345678 Connection: Check Dialup 5/6/12
Dialup Entry Name: PNMT (USB) And then click Login, Login, follo followin wing g wind window ow will will appea appear. r.
5/6/12
For any configuration on NEC we have to ON the option of Maintenance for it, for that we will go to MAINT option then turn ON the option for Maintenance, it will then turn in to yellow. yellow.
5/6/12
Note: Remember for Link panning we have to turn ON the Antenna Alignment mode as well along with Maintenance mode in similar manner.
5/6/12
IP Configuration: For IP configurations go to CRTL option as shown below,
5/6/12
It will then open a window shown below; we have to then click on option Equipment Network Setting.
5/6/12
Now we can have two scenarios here, • NE • Root NE • For NE select the CTRL Type Normal NE and then implement the IP Plan accordingly,
5/6/12
5/6/12
For Root NE select the CTRL Type Root NE and then implement the IP Plan.
5/6/12
Note: Don’t forget to click on Execute once you have implemented the IP Plan. After executing the IP Plan Link will automatically restart.
5/6/12
Setup Configuration: First go to Configuration option in main window window Then Then Equ Equipm ipment ent Setup Setup The Then n press press Setup there Then press Configure there.(See below below figu figure re for for the the refere reference nce,, All window windowss are opened. The options which we have to click are marked with Red small box)
5/6/12
5/6/12
We have to give here here b/m settings, Redundancy Setting: If the link li nk is 1+0 then we have to select option of 1+0(TERM) 1+0(TERM) else we have to select 1+1(Hot standby)
Ø
Ø
Main(Work) – INTFC: We have to select 4Port LAN with wi th E1(VLAN)
Ø
LAN Port Usage: This option should be Port Shared
Ø
Radio Mapping: P1-P2-P3-P4=(Dep P1- P2-P3-P4=(Depends ends upon Link 40/100/150Mbps)
Ø
TX RF Freq: Insert the freq as per Link Budget.
Ø
Frame ID: It should be same on both ends
Ø
TX Power Control: MTPC
5/6/12
Note: See figures below for the reference how to insert the above things in software. All values below below are imagin imaginary ary;; we we have have to insert insert the them m as as per our LB and and IP Plan. Don’t Don’t forget to execute after inserting all values.