nastran error list

November 23, 2017 | Author: Achyuth Rao | Category: N/A
Share Embed Donate


Short Description

nastran error list...

Description

MD Nastran/MSC.Nastran Complete Error List Current Update: Jan 14, 2011 -----------------------------------------This section includes a description of all known errors and general limitations in all releases of MSC.Nastran and MD Nastran. The "version is the version on the f06 title page". Recent versions are sometimes referred to by the CD id as follows: MSC.Nastran 2005R3 = 2005.5.0 MSC.Nastran 2005R3b = 20005.5.2 MD Nastran R1 = 2006.0.0 MD Nastran R2 = 2007.0.0 MSC.Nastran 2007r1 = 2007.0.0 MD Nastran R2.1 = 2007.1.0 MD Nastran R3 = 2008.0.0 MD Nastran 2010 = 2010.1.0 MD Nastran 2010.1.1 = 2010.1.1 MD_MSC Nastran 2010.1.3 = 2010.1.3 If the Version = "GL" then this indicates a General Limitation which indicates a fix is not planned. Continuous updates to the error list are available to MD Nastran / MSC Nastran clients on the MSC SimCompanion web page http://simcompanion.mscsoftware.com/infocenter/index?page=content&id=KI8008006 The MSC Support pages can also be used to search for keywords to easily locate individual errors - http://simcompanion.mscsoftware.com

Known Error

CR 399

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Eigenvalue Analysis - CEAD, QRG - Unexpected Normalization

Description

Complex eigenvalue analysis with the inverse power method of eigenvalue extraction will always normalize to MAX. POINT normalization requests are ignored. The Version 70.5 Quick Reference Guide has been updated to indicate that point normalization is only available for the det method.

Known Error

CR 785

Product

MSC / MD Nastran

Corrected Version 69 Abstract

MSGMESH, MSGSTRESS, MSGVIEW - MSGMESH, DIAG 29 - Infinite CPU Loop

Description

If MSGMESH is used with the link specification update feature, an infinite loop occurs. An infinite loop no longer occurs; UFM 53 will be issued indicating an incorrect format for the mesh entries.

Known Error

CR 868

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Miscellaneous - PUNCH - Incorrect Format

Known Error

CR 868

Description

STRESS(PUNCH) will not properly output the HEXA, PENTA, BEND, BEAM, TRIA6, or QUAD8 elements. Element margins of safety (ROD, CONROD, TUBE, and BAR elements) will produce poor punched formats if stress allowables are not given on the referenced MATi entries.

Known Error

CR 890

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

Grid Point Force - GPFDR - UFM 3008 The open core requirement for the GPFDR module can be as large as (6 X BUFFSIZE + 14 X number of grids) if the grids use a nonrectangular displacement coordinate system. For problems in basic coordinates, the grid requirement drops to 8 X number of grids.

Known Error

CR 1103

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

Dynamic Response - TRD, TRD1, FRRD, FRR - UFM 3005 If the MGIV method of real eigenvalue extraction computes modes for massless DOF with uncoupled stiffness terms, the eigenvalue is large (1.E+35) as it should be, but the generalized stiffness is 0.0 (it should also be 1.E+35). Null eigenvectors may be produced. An avoidance is to use PARAM,HFREQ or PARAM,LMODES to discard these bad modes in dynamics.

Known Error

CR 1357

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Aeroelastic Analysis - GI - Poor Accuracy

Description

The linear splines used to connect structural and aerodynamic degrees of freedom are sensitive to modeling techniques, particularly on short-word machines. This included all machines except CRAY, CDC and NEC. It is good practice to have the spline axis coincide with the structural grid points, and to avoid discontinuities in the lines joining structural grid points by using separate splines on each side of the discontinuity.

Known Error

CR 1575

Known Error

CR 1575

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Dynamic Response - VDR - No Output If an OUTPUT(XYPLOT) command is in case control, but there are no other XYPLOT commands, all printed output requests are ignored. An avoidance is to put in XYPLOT requests or remove the OUTPUT(XYPLOT) command.

Known Error

CR 1679

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Elements - QUAD4,TRIA3 - Wrong Answers When the MID4 option of the PSHELL card is used to simulate offset of the element centerline from the grid point plane, the element is somewhat too stiff. The error increases with the ratio of offset to element width. An avoidance is to use RBAR elements to model the offsets .

Known Error

CR 1712

Product

MSC / MD Nastran

Corrected Version GL Abstract

Frequency Response Analysis - RANDOM - SWM 3002, UWM 979 If a non-existent point is referenced in an output request when there are multiple subcases, the RANDOM module will cease processing at that point and issue SYSTEM WARNING MESSAGE 3002. The following user warning message is now issued:

Description

0*** USER WARNING MESSAGE 979, AN XY-OUTPUT REQUEST FOR POINT OR ELEMENT ID 2000 -ACCE- CURVE IS BEING PASSED OVER. THE ID COULD NOT BE FOUND IN DATA BLOCK 102

Known Error

CR 1738

Product

MSC / MD Nastran

Corrected Version 66

Known Error

CR 1738

Abstract

Grid Point Stress - Preface - UFM 603

Description

If the SURFACE Case Control card has a continuation card, and the first words that appear on this card are OUTPUT SYSTEM, the error occurs. An avoidance is to start the continuation with another word.

Known Error

CR 1739

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

DMAP - DIAG 4 - Addressing ERROR If DIAG 4 is used on restart, the program may exit abnormally at the start of the run. The DIAG 4 cross reference output for Label Names will be incorrect if no labels exist in the DMAP, and the parameter section of the cross reference will not contain any parameters although parameters are present. An avoidance is to put a label in the DMAP.

Known Error

CR 1758

Product

MSC / MD Nastran

Corrected Version GL Abstract

Cyclic Symmetry - Restarts - Various In superelement static cyclic symmetry (SOL 81), some restart paths do not function well. The following restart paths have been demonstrated to work, using the indicated input and DMAP Alters. Other types of restarts can be made, using these techniques. A. Conventional Superelement Restarts.

Description

Use the same techniques applicable to noncyclic symmetry superelement analysis. 1. Exit during Phase I. 2. Structural Changes in a Superelement. 3. Load Change Restart

B. Time Limit in a Harmonic Loop SET N = 0, residual only

Known Error

CR 1758 SEMG = N PARAM,RESDUAL,-1 (bulk data) Input all bulk data, or use PARAM,NODATA,-1 and delete all the bulk data except PARAM entries.

C. Loads Change in One Tip Superelement, Same Number of Loading Conditions, Sam Known Error

CR 1759

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Plotting - RF24D20, Superelement - Wrong Labels If SPC labels at grid points are requested for plotting ("GSPC") and resequencing is requested, the SPC labels are attached to the wrong components. An avoidance is to make a separate run for these plots without resequencing, and insert an EXIT after the RFAlter, or not request the SEKR operation in superelements.

Known Error

CR 1765

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Cyclic Symmetry - CYCLIC2 - UFM 3005, UFM 4319, UWM 4359 There are two errors related to the use of the CYSUP Bulk Data entry when rotational symmetry is applied to a model with three or more segments.

Description

1. If the rigid body rotations are to be supported, but there exists no stiffness at the components specified on the CYSUP entry, then UFM 3005 may be issued. But, if components 4 and 5 (out-of-plane rotations) are then constrained by an SPCi card or a GRID card, in order to avoid UFM 3005, then UFM 4319 will be issued. For components 4 and 5, an avoidance of UFM 4319 is to define rotational springs to ground (e.g., CELAS2). For component 6 (in-plane rotation), an avoidance of UFM 3005 is to apply a single-point constraint (e.g., SPCi), which is contrary to Remark 1 under the CYSUP Bulk Data entry description. b. The specif

Known Error

CR 1801

Product

MSC / MD Nastran

Corrected Version 66 Abstract Description

Plotting - PLOT - SFM 4276 If modern plate elements are present, and SHRINK or DIAG 34 are requested, the error may occur.

Known Error

CR 1802

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Miscellaneous - Preface - CPU Loop If the THRU range on an input card is larger than 131,071 for CDC/7600 and CYBER computers, or 8,388,608 for CRAY computers, the error may occur. It has been observed on a PLOAD2 card with a larger range. (Cyber,CDC 7600,CRAY only) An avoidance is to split the THRU range into smaller sets, so that none exceeds the limit.

Known Error

CR 1803

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Elements - PQUAD4 - UFM 2010 If both PQUAD4 and PSHELL (and/or PCOMP) cards exist in the same deck, the misleading message references PSHELL cards. The PQUAD4 card is obsolete, and is removed from current documentation. It should be replaced with the PSHELL card. The PQUAD4 card will be deleted from the code on a future system. An avoidance is to replace PQUAD4 card with PSHELL cards wherever they exist as they cause various confusing errors.

Known Error

CR 1804

Product

MSC / MD Nastran

Corrected Version 66 Abstract Description

Superelements - SELA - Wrong Answers

Known Error

CR 1804 For large problems, if the first several upstream load vectors are null, the remaining upstream load vectors may be ignored. This can be detected with DIAG 20. An avoidance is to place a token load on all upstream superelements.

Known Error

CR 1805

Product

MSC / MD Nastran

Corrected Version 66 Abstract Description

Elements - PCOMP - Wrong Answers For layered composite materials with an unsymmetric layup, the generated transverse shear matrix MID3 is incorrect.

Known Error

CR 1806

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Database - LOAD/UNLOAD - Wrong Answers If a database is unloaded to a sequential file using the DBMGR //3 command, then restored to a direct access file using the load command, any keywords stored in the database dictionary will be lost. Most keywords are only for diagnostic use (i.e., "SEMGDONE"), and will cause no further errors. The one exception at present is the keyword "NOSETRUE", which appears when all grid points are in the residual structure. This will cause the fatal message above on PARAM,NODATA or PARAM,DLOAD restarts. An avoidance is to use the following alter for this type of restart: ALTER 10 $ MSC/61B, AFTER DBMGR //11 SETVAL //V,N,NOSE/-1 $

Known Error

CR 1807

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Matrix Methods - FBS, Method 2 - Wrong Answers

Description

If a passive group appears within the first 20 columns of a matrix, some terms may be dropped. The error was first observed on a large static reduction. An avoidance is to block Method 2 by using the NASTRAN card entry FBSOPT=-1,

Known Error

CR 1807 when passive columns occur.

Known Error

CR 1808

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Database - DBSTORE - DBM 288 This error occurs when more than 32,768 GINO blocks are stored in a single database, and a store of an equivalenced file is attempted. (IBM only) An avoidance is to use several databases, none larger than 32,000 GINO blocks.

Known Error

CR 1809

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Heat Transfer - HBDY - Wrong Answers

Description

SOL 74 gives wrong answers for nonlinear HBDY types AREA3 and AREA4. An avoidance is to use the POINT option instead.

Known Error

CR 1810

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Elements - Midside Nodes - Wrong Answers The QUAD8, TRIA6, and HBDY elements use an incorrect average temperature for material properties when the number of active grid points is not the same for all elements of the same type. (Deleted midside grid points are not active grid points; all connected grid points are active.) An avoidance is to delete the same number of nodes on all elements of the same type in the model.

Known Error

CR 1811

Product

MSC / MD Nastran

Corrected Version 69 Abstract Description

Dynamic Response - SDR3 - UFM 4605 If DISP, VELO, or ACCE are requested for a set of grid points and the

Known Error

CR 1811 set is empty, USER FATAL MESSAGE 4605 occurs. An avoidance is to remove output requests for empty sets.

Known Error

CR 1812

Product

MSC / MD Nastran

Corrected Version 66 Abstract Description

Miscellaneous - Multiple Runs - ITRENT 1111 If two or more MSC/NASTRAN executions are made in the same job, the error may occur. (Univac only) An avoidance is to submit each run as a separate job.

Known Error

CR 1813

Product

MSC / MD Nastran

Corrected Version Abstract

Description

Response Spectra - PARAM,RSPECTRA,0 - Wrong Answers The response spectra option provided in transient analysis gives wrong answers for acceleration spectra at high frequencies. The peak accelerations for high frequency oscillators will not match the results of a transient analysis where a stiff spring and small mass have been attached to the structure to directly represent the oscillator. The displacement and velocity from the response spectra results will match those of the oscillator represented with spring and mass. Avoidance: The user should set the value of delta t on the TSTEP input such that 10 time steps occur during one cycle of oscillation for the highest frequency of interest.

Known Error

CR 1814

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Matrix Methods - MPYAD - Overflow If incompatible matrices are input to the MPYAD module, and one is of form 3, an unclear diagnostic results. A good practice is not to input form 3 matrices to MPYAD, as this capability will be removed in a future system. The form 3 matrix [A] can be changed to form 6 by the following steps: ADD A, /A6 $ ADD WILL GENERATE PROPER MATRIX EQUIV A6,A/ALWAYS $ A6 REPLACES A

Known Error

CR 1815

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Dynamic Response - XYPUNCH - Missing Output The PCHRESP parameter described on p. 4.3-23 (2/15/82) of the MSC/NASTRAN User's Manual is not implemented. The function it was to perform (punch TABLED1 cards based on output data) can be performed with a DMAP Alter. Delete the XYTRAN module statements, and replace them with an identical statement except for the sixth parameter. Set it to S,Y,PCHRESP=0. (MSC/62 only)

Known Error

CR 1816

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Material Nonlinearity - SOL 66 - Wrong Answers If the large displacement option is used, and more than one rotation is enforced at a grid point with SPCD cards, the transformations are incorrect when increments are specified on the NLPARM card. An avoidance is to use separate subcases, each with a single increment, rather than many increments on a single subcase. (MSC/62 only)

Known Error

CR 1817

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Transient Response - TRD1 - UFM 3050 If an IC card is selected in case control in SOL 31, which is illegal, the wrong fatal message ("insufficient time") is printed. The correct text can be found under UFM 3051, listed in Section 6 of the U.M.

Known Error

CR 1819

Product

MSC / MD Nastran

Corrected Version 66 Abstract Description

Elements - EMG - EMGPOM If HEX8 and HEX20 elements are used with other elements, and there

Known Error

CR 1819 is insufficient memory available, unclear diagnostics may result. (IBM, Cyber, CDC/7600, CRAY, Univac only) An avoidance is to request more memory.

Known Error

CR 1820

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Database - DBSTORE - SFM 4167 The maximum number of database dictionary entries is influenced by the fourth input parameter for the DBMGR command when creating the database. The default value will almost always result in more than one GINO block being used for the dictionary. If the dictionary has only one block, the database will be unusable. (Univac only) An avoidance is to insure that the dictionary is assigned more than one block. This can be determined from SIM 4162, under the "WRITTEN" entry. This number should be greater than 1 when the database is created. If it is not, increase the fourth input parameter to at least twice the value printed under the "NUMBER OF ENTRIES MAXIMUM" for SIM 4162.

Known Error

CR 1821

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Superelements - Documentation - Wrong Answers The DMAP Alter described in the Application Note of January 1982 titled "Inertia Relief in Superelement Analysis" has a typographical error that causes inertia loads of the wrong sign. The second to last statement on page 7 should be changed from SOLVE QRR,QR/CRX/ $ etc. to SOLVE QRR,QR/CRX//-1 $ Update pages for the application note will be delivered with the next newsletter.

Known Error

CR 1822

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Material Nonlinearity - MID3 - Wrong Answers

Known Error

Description

CR 1822 In SOL 66, the values output for transverse shear forces for the QUAD4 and TRIA3 elements are incorrect if MID3 (field 7 on the PSHELL card) is nonzero. An avoidance is to leave MID3 blank.

Known Error

CR 1823

Product

MSC / MD Nastran

Corrected Version 66 Abstract Description

Miscellaneous - 1VARY - UFM, CARD TO VARY NOT FOUND Multiple 1VARY cards for the same type of data card may not sort correctly.

Known Error

CR 1824

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Matrix Routines - Method 3 - Various GINO Messages If Method 3 matrix multiplication is selected, and there is not sufficient memory available, various system errors may occur. The method selected can be determined by DIAG 19. Avoidances are to increase memory, or block Method 3.

Known Error

CR 1825

Product

MSC / MD Nastran

Corrected Version 66 Abstract Description

Elements - Punched Output - Extra Output If output is requested in punched format, elements whose printed formats include more than one element per line will also print the last few elements, if they do not fill the line.

Known Error

CR 1826

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Cyclic Symmetry - SOL 77 - Parameter Print If illegal loads are requested in buckling analysis using cyclic symmetry, the program branches from the CYCLIC1 module to the PRTPARM module, then prints all parameters. This condition can be detected by noting that parameter GEOM3C has the value

Known Error

CR 1826 minus one. One such case was observed when GRAV entries were selected. This user error now results in a meaningful fatal message: 0*** USER FATAL MESSAGE 4342, THE LOAD BULK DATA CARD GIVEN BELOW IS INCONSISTENT WITH SPECIFIED ANALYSIS HARMONICS OR SEGMENTS OR SYMMETRY TYPE.

An avoidance is to check the load entry types against the limitations described in Section 3.2 of the Application Manual. Known Error

CR 1827

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Grid Point Stress - Branched Surface - Wrong Answers When requesting stresses for a surface with branches using geometric interpolation without a value for tolerance, some stresses at branch points may be incorrect. An avoidance is to use the BRANCH option.

Known Error

CR 1828

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Heat Transfer - CFTUBE - Wrong Answers If the CFTUBE is used in SOLs 24, 61, or 62, which is illegal, SOL 24 produces wrong answers, and the others fatal error message GETSTB ERROR CODE 1604 or some equivalent message in the SSG3 module. CFTUBE elements are supported only in SOL 74.

Known Error

CR 1829

Product

MSC / MD Nastran

Corrected Version 66 Abstract Description

Database - DBMGR, DBSTORE - IO6600 F.E. 1203

Known Error

CR 1829 Any database file longer than 262, 143 PRUs may fail with this error on restart. An avoidance is to restrict all database files to be under this size. The size of a database is specified in GINO blocks. A good approximation of the maximum allowable number is one million/SYSBUF. (SYSBUF is the size of the GINO buffer, which has a default of 1792.) Thus with default buffer size, limit database files to about 8900 blocks. (CDC/Cyber running under NOS only.)

Known Error

CR 1830

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Aeroelastic Analysis - FA1 - Wrong Answers The ATEIG subroutine for eigenvalue solution has a limit of 30 iterations. If convergence is not achieved, the subroutine continues with intermediate results without giving a warning message. This yields incorrect eigenvalues for that condition. This has been detected when implausible real eigenvalues were produced when complex eigenvalues were expected.

Known Error

CR 1831

Product

MSC / MD Nastran

Corrected Version 66 Abstract Description

Superelements - UMERGE - SFM 3007 In SOL 62, if a data recovery restart is made while performing no Phase I operations, the error will occur. An avoidance is to add PARAM,NORSET,-1 above the subcase level.

Known Error

CR 1832

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Static Analysis - RF24D13B - SFM 4275 The error occurs when the RF Alter is used for restarts where only output requests are changed, but not loading conditions. The RF Alter should not be used for this condition. A standard restart may be used.

Known Error

CR 1833

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Material Nonlinearity - SOL 66 - UFM 1105 If CHKPNT YES appears in the Executive Deck, the error may occur at random places. If checkpointing is required, use the alter: ALTER 1 $ PARAM //DIAGOFF//47 $ In general, it is more efficient to recover the input data from the database rather than use checkpointing.

Known Error

CR 1834

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Elements - ROD,HEXA - Wrong Answers In SOLS. 64, 66, and 99 the following errors occur: A. ROD elements give wrong answers if they have torsion properties (J>0.), and the element changes direction, even slightly, due to large deflection effects. B. HEXA elements give wrong answers when two of the axes X,Y, or Z (see U.M. p. 2.4-70) are of nearly equal length (that is, the element has almost square faces) and are not perpendicular. (Part B fixed in Version 62A)

Known Error

CR 1835

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Plotting - XYPLOT - Poor Efficiency If a plot is made of a constant function, such that the maximum and minimum y values are the same, the automatic scaling algorithm may converge very slowly. This problem has been observed only on CYBER computers, where it appeared to be a CP loop. An avoidance is to set one of the scales manually with the plotting commands YMIN=0.0; YTMIN=0.0; YBMIN=0.0.

Known Error

CR 1836

Product

MSC / MD Nastran

Known Error

CR 1836

Corrected Version 66 Abstract

Description

Restarts - Preface - IO66RD F.E. 314 For CYBER computers using the SCOPE 3.4 operating system, the error will occur if the buffer size is greater than 512 words, and the NPTP is sent directly to TAPE. An avoidance is to use the "L" parameter on the "REQUEST, NPTP..." card.

Known Error

CR 1837

Product

MSC / MD Nastran

Corrected Version 66 Abstract Description

Executive - SOL 76 - SFM 14 All of the solution sequences will compile in the recommended default region of 200K octal except SOL 76. It will compile with an RFL of 205K octal. (CYBER only)

Known Error

CR 1839

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Heat Transfer - SPCD - Wrong Answers If an enforced temperature is input on SPC or SPCD cards in SOL 74, wrong answers result. An avoidance is to place the degree of freedom on a SPC1 card, and set its value with a TEMP Bulk Data card.

Known Error

CR 1840

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Dynamic Response - OLOADs - Missing Output If plots or print of OLOADs are requested in SOLs 70-72, 75, or 76, and there are no extra points, the error occurs. An avoidance is to place the following alter before the DMAP statement DBSTORE PGD, etc. For SOL 72, for example, the alter is: ALTER 974 $ MSC/62 EQUIV PP, PGD/NOUE $

Known Error

CR 1841

Product

MSC / MD Nastran

Corrected Version 66 Abstract Description

Matrix Methods - DECOMP - LOGIC ERROR 582 For unsymmetric decomposition with spill, the error may occur. (CYBER only) Changes in region size sometime eliminates the problem.

Known Error

CR 1842

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Sequencing - SEQP - Various System Errors If the resequencing module spills in the SEQMR subroutine, various system errors occur. (CRAY, VAX, UNIVAC only). Avoidances are to: A. Increase the memory request, or B. Use PARAM, MPCX, -1.

Known Error

CR 1843

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Elements - BEND - Wrong Answers

Description

The BEND element produces incorrect element forces and stresses when thermal loads are applied to them.

Known Error

CR 1844

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Elements - PCOMP - Wrong Answers

Description

The interlaminate shear stresses are incorrect for laminae that have nonzero orientations.

Known Error

CR 1845

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Virtual Mass - XYPLOT - Missing Plot Output

Known Error

Description

CR 1845 XYPLOT requests for MPRES output are ignored. An avoidance for SOL 31 is: ALTER 548 $ AFTER MDATA MSC/61, MSC/62 SDR3 OEP,,,,,/OEP2,,,,,/ $ XYTRAN XYCDB,,,,OEP2,/XYPPLOT/SOLTYPE/DSET/S,N,PFILE/ S,N,CARDNO/S,N,NOPLOT $ COND NOPPLOT,NOPLOT $ XYPLOT XYPPLOT // $ LABEL NOPPLOT $ Other solution sequences may also use this alter if appropriate changes are made to the alter line number. This error is fixed in the sss solution sequences; however the xyplot request is pres not mpres.

Known Error

CR 1846

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Transient Nonlinear Analysis - XYPLOT - Missing Plot Output

Description

In SOL 99, an XYPLOT requests may be ignored when there is no printed output requested. An avoidance is to request at least one grid point for printed output.

Known Error

CR 1847

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Material Nonlinearity - TABLES1 - Wrong Answers In solutions 66 and 99, if the stress-strain curve does not pass through the origin for FORM=1 the data is accepted, producing unrealistic answers. On future systems, such input will cause a fatal error.

Known Error

CR 1848

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Superelements - SEP2 - UFM 4222

Description

If SEUSETi cards reference interior points, the error occurs. They may be applied to exterior points. In

Known Error

CR 1848 future systems they may also be applied to interior points.

Known Error

CR 1849

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Superelements - SEUSET - UFM 315

Description

The card description of this card in Section 2.4 of the User's Manual has fields 2 and 3 interchanged. The correct format is: SEUSET, (SEID), (SNAME), ...

Known Error

CR 1850

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Cyclic Symmetry - GPFDR - UWM 2342,2354

Description

In SOL's 81 through 83, the message results when GPF0RCE or ESE output is requested. An avoidance is to delete the DMAP line number for the GPFDR module, and change the APP parameter to APP1. For example, ALTER 822,822 $ SOL 81, MSC/62 GPFDR CASEDR,UGVS,KELM,KDICT,ECTS,EQEXINS, GPECT,PG,QGS,BGPDTS,SILS,CSTMS,VELEM/ONRGY1, OGPFB1/APP1/V,Y, TINY $

Known Error

CR 1851

Product

MSC / MD Nastran

Corrected Version 66 Abstract Description

Matrix Routines - MPYTIM - Integer divide by zero If large problems are run with small memory requests, the error may occur. An avoidance is to increase the memory request.

Known Error

CR 1852

Product

MSC / MD Nastran

Corrected Version 66

Known Error

CR 1852

Abstract

Restart - Dynamics - No Damping

Description

If a restart is made from SOL 24 to a dynamics solution sequence, any damping cards present in SOL 24 (i.e. CVISC) may be ignored. An avoidance is to delete one damping card on restart and reinsert it.

Known Error

CR 1853

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Executive - 3380 Disk Drives - Various System Errors (21OCT82) Users may not run any version of MSC/NASTRAN prior to MSC/62 on an IBM configuration that references 3380 disk drives. A variety of I/O related fatal messages may result from the earlier version's inability to compute blocksize correctly on these drives. The most likely messages are one or more of the SFM 4212 codes. Some users have had limited success by using half-track blocking with Version 61B. However, use of Version 62 is the recommended procedure. Furthermore, users may not copy (using IBM utilities) a MSC/NASTRAN database existing on non 3380 disks to a file usable by MSC/NASTRAN on a 3380 disk. (IBM only) This procedure may be accomplished however, by using a short MSC/NASTRAN DMAP sequence to read the existing file from the non 3380 disk and then write a

Known Error

CR 1854

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Material Nonlinearity - EMG - SFM 3007 If a SOL 66 run restarts from a prior run which had no updates of the stiffness matrix, the recovered stiffness matrix may be incorrect. An avoidance is to restart the run from the beginning.

Known Error

CR 1855

Product

MSC / MD Nastran

Corrected Version 66

Known Error

CR 1855

Abstract

Material Nonlinearity - Contour Plots - SFM 4276

Description

In SOL 66, when contour plots are requested for both linear and nonlinear elements, SFM 4276 will occur. Also, if all elements are linear, SFM 3002 might occur. An avoidance is to make linear elements into nonlinear elements by setting the yield stress very high.

Known Error

CR 1856

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Superelements - Multiple File databa - Purge of Upstream database If PARAM, DBSET1 is set to a value greater than zero, the entire upstream database will be purged during the SEKR operation. An avoidance is to repair two database purge statements that are in error. For SOLUTION 61, the fixes are: ALTER 440,440 $ MSC/62 DBMGR //5/MODEL/SEID/0/DBSET1//GO$ ALTER 452,452 $ DBMGR //5/MODEL/SEID/0/DBSET1//KTT$ The change involves inserting a "0" parameter before DBSET1, and reducing the number of slashes after DBSET1 from three to two. Two similar statements will be found in all the superelement solution sequences, at different line numbers. They can be found by use of DIAG 14, followed by a search for statements of the form: DBMGR //5... GO $, and DBMGR //5..... KTT $ This error does not affect superelement run

Known Error

CR 1857

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Miscellaneous - RF24D40 - Various Fatal Messages or Wrong Answers If a user-supplied DMAP loop is provided around this alter, and the FBS module is within this loop it will result in various fatal messages or wrong answer after the first pass. An avoidance is to copy and modify the alter by inserting the following two DMAP statements; After the first ALTER statement insert: PARAM //STSR/V,N,SAVE74/74

Known Error

CR 1857 $ Just after the third occurrence of the SDR2 module insert: PARAM //STSR/V,N,SAVE74/-74 $

Known Error

CR 1858

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Miscellaneous - Demand Runs - FATAL MESSAGE 202 If two or more MSC/NASTRAN executions are made in the same demand session, the error may occur. (Univac only) An avoidance is to free all MSC/NASTRAN files (i.e. PRIXX, and SECXX's) between executions in demand mode.

Known Error

CR 1859

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Miscellaneous - IBM - Compilation Errors The UTIL data set which is the third data set on the IBM deliverable tape was incorrectly blocked at 13030 bytes. This is acceptable except for installations having only DASD devices which support shorter maximum blocksizes (i.e. 3340 devices). At these sites the UTIL data set, as issued, cannot be restored. The most heavily used programs in the UTIL data set are DECKEDIT, NASTPLOT and TECKPLT. Of these, DECKEDIT and NASTPLOT are available in the NASTRAN data set which is the second file on the deliverable tape. TECKPLT is identical with the program as issued in Version 61 and could be obtained from that source. If any other programs are required from the UTIL data set, or any of the above solutions are unacceptable, please contact MSC. (IBM only) An avoidance, i

Known Error

CR 1860

Product

MSC / MD Nastran

Corrected Version 66 Abstract Description

Material Nonlinearity - TA1 - Wrong Answers or Overflow

Known Error

CR 1860 In SOL 66 and 99, Orthotropic Materials defined by MAT2 or MAT9 do not work in SOL 66 or SOL 99 for any type of elements.

Known Error

CR 1861

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Geometric Nonlinearity - EMA - Overflow In SOL 64, 66, or 99, if the static displacement vector provided to the second subcase for differential stiffness calculations is null, the results of the second subcase may be implausibly large, or the EMA module may first terminate due to overflow. An avoidance is to request loads in the first subcase that will produce a nonnull displacement vector.

Known Error

CR 1863

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Known Error

Superelements - Dynamics - No Damping The Application Note of May 1981 describes a method for obtaining differential stiffness effects in dynamic analysis by performing a static analysis in SOL 64, followed by a special restart into SOL 63, or SOL's 67 through 72. At present, damping is not computed in SOL 64, and may not be computed on the restart run without erasing the differential stiffness matrix. The following alter will provide damping: Alter for damping in SOL 64 /61B or /62 ALTER 62,62 $ MSC/61B/62, SOL 64 EMG EST1,GCSTMS,GMPT,GDIT,GGEOM2,,,/ KELM1,KDICT1,MELM,MDICT,BELM,BDICT/ S,N,NOKGG=1/S,N,NOMGG=1/S,N,NOBGG=1/// V,Y,COUPMASS=-1 $ ALTER 68 $ EMA GPECT,BDICT,BELM,GBGPDT,GSILS, GCSTMS/BJJ, / $ DBSTORE BJJ//MODEL/0 $ CR 1864

Known Error

CR 1864

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Superelements - Documentation - H/SEA The following errors have been found in the Handbook for Superelement Analysis, for Version 61. 1. Appendix J, page 3 Deck SEH616A Add after "DBSTORE EQEXINS..." DBMGR //7/////-2/UGVS/ULV $ This statement is needed to provide the presence of ULV for the next run, Deck SEH617. Its absence causes the data recovery run for the external superelement to terminate without producing output. 2. Appendix J, pages 4 and 5 Several decks use the DBMGR //3 and DBMGR //4 commands. They use the default values for the third parameter, used for "search control". The default value allows several blocks with the same name to appear in the data base, which can lead to baffling fatal errors or wrong answers. It is good practice to set the third parameter

Known Error

CR 1865

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Geometric Nonlinearity - SOL 66,99 - Wrong Answers If SOL 66 or 99 is used with only LGDISP, the beam element has incorrect stress recovery output, if I1 does not equal I2. Output (recovered) stresses are only affected, and the solution is still correct. An avoidance is to either: 1. Make a "Dummy" material nonlinear group (w/yield stress set to a high value) 2. Run only with I1 equal to I2.

Known Error

CR 1866

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Material Nonlinearity - SOL 66, 99 - Wrong Answers

Description

In SOL 66 or 99, a beam element with thermal loads and nonbasic coordinates

Known Error

CR 1866 used by its end grid points gives incorrect results. An avoidance is to use the basic coordinate system to define the beam element grid points.

Known Error

CR 1867

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Cyclic Symmetry - Restarts - Missing Modal Deformation Plots

Description

In SOL 48 restarts, requests for modal deformation plots are ignored unless the requests were also made in the cold start. The following alter is an avoidance: ALTER 197 $ MODTRL FCASEBK1 /////1// $

Known Error

CR 1868

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Grid Point Stress - Subcases - Wrong Answers When there are multiple subcases in a run and in a particular subcase there is a stress request but not a grid point stress request then the subsequent subcase grid point stress results will be wrong. This is a stress recovery error only and does not effect the solution. An avoidance is to put grid point stress requests (even if for only one element) in every subcase.

Known Error

CR 1869

Product

MSC / MD Nastran

Corrected Version 69 Abstract Description

Geometric Nonlinearity - SSG1 - GINO Fatal Message 3029 In SOL 64, if only GRAV Loading is being used, GINO Fatal 3029 will occur in Subcase 2. An avoidance is to include a dummy load.

Known Error

CR 1870

Product

MSC / MD Nastran

Corrected Version 66

Known Error

CR 1870

Abstract

Miscellaneous - Composite Element wi - Incorrect Resutlsts

Description

Thermal loading at grid points (using TEMP or TEMPD) gives wrong temperature gradients and corresponding incorrect results in composite elements. An avoidance is to apply TEMP loads directly to elements.

Known Error

CR 1871

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Cyclic Symmetry - Thermal Loads - Wrong Answers or UFM 4587 Temperature load cases, i.e., TEMP(LOAD)=j in SOL 81, combined with other types of loads will provide incorrect force and stress output because the thermal strains are not correctly handled. If temperature loading only is requested, then UFM 4587 will occur. This situation arises because the identification number of the temperature load "j" is not included in the CASEDR data block output by the SEDR module. An avoidance is to utilize the following alter: ALTER 642 $ MSC/63 $ALTER 653 $ MSC/62 TABEDIT CASEDR, CONT,,,/A1 $ EQUIV A1, CASEDR/ALWAYS $ in the Executive Control Deck, and to include the following DTI cards in the Bulk Data Deck: DTI, CONT, 1, CR, [1] , DW, 7, 7, 1, DTI1 +TI1, "j" ENDREC DTI, CONT, 2, ER, ENDREC The number in brackets, i

Known Error

CR 1872

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Matrix Methods - MPYAD - Mode Error 1 This error condition may occur when multiplying large matrices. It is further characterized by aborting with a "P address" between 36000 and 37400. The P address is printed out in the dump on the line that starts "P ="). This error was reported to be fixed in Version 62A, in a prior report.

Known Error

CR 1872 Field usage of Versions 62A shows that the fix was not fully effective. (CYBER, CDC/7600 only) Avoidances are to: 1. RFL up or down by about half of the largest dimension of any input matrix. 2. Set the REAL parameter on the NASTRAN card to core size minus the largest dimension of any input matrix. Core size may be determined from DIAG 13. 3. Deselect Method 1 and Method 1T. This should be done locally using a DMAP Alter statement, rather than on the NASTRAN c

Known Error

CR 1873

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Description

Miscellaneous - PARM Field - Incorrect PARMs The PARM option provided in the PROC delivered with NASTRAN allows up to 100 characters of input, based on inherent JCL limits. (See Section 7.6.2.1 of the A.M.) Submitting more data results in JCL fatal error messages. MSC/NASTRAN will process less data than this, however, with the remaining data set to unpredictable values. The equation for the limit of data properly processed by MSC/NASTRAN is 4S*7+(OTHERS)*4 NGMAX where NGMAX = NCON + NDV

Description

and NAVC = # of active and violated constraints considered by the DOT algorithm NASIPE = # of active side constraints NCON = # of retained constraints passed to the optimizer NDV = # of design variables Generally, DOT selects a small set of NCON for NAVC. In the case that encountered the failure, there were a large number of properties an

Known Error

CR 4469

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Data Recovery - DTI,INDTA - Composite Stress Sorting Composite ply results processing does not support the DTI,INDTA Bulk Data entry.

Description

Avoidance: The following DMAP statement needs to be modified in each applicable Unstructured Solution Sequence and in the subDMAP SEDRCVR as follows:

Known Error

CR 4469 (old) STRSORT ES1C,/OES1C/V,Y,NUMOUT1=-2/V,Y,BIGER1=0.0 $ STRSORT EFIT,/OEFIT/V,Y,NUMOUT2=-2/V,Y,BIGER2=0.0 $ (corrected) STRSORT ES1C,INDTA/OES1C/V,Y,NUMOUT1=-2/V,Y,BIGER1=0.0 $ STRSORT EFIT,INDTA/OEFIT/V,Y,NUMOUT2=-2/V,Y,BIGER2=0.0 $ Alternatively, the analyst may use the default ply sorting with parameters NUMOUT1,NUMOUT2,BIGER1, and BIGER2. This gives sorting on the ply stresses and strains.

Known Error

CR 4476

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

Elements - PSOLID - UWM 5460 If the standard isoparametric integration (ISOP=FULL) is desired for the CHEXA or CPENTA element with midside nodes, and the IN field is blank on the PSOLID entry, then MSC/NASTRAN assumes that the user wants to use bubble functions. "USER WARNING MESSAGE 5460, ILLEGAL OPTION ON PSOLID ID = ***, FOR BUBBLE FUNCTION. ONLY REDUCED INTEGRATION IS ALLOWED" is issued, and the run will proceed using reduced integration. The same warning message is issued for CTETRA elements if the IN field is blank even though bubble functions and reduced integration are not supported by this element. The run will continue with the default integration options. Avoidance: To perform standard isoparametric integration on CHEXA and CPENTA elements with midside nodes, IN must be set to 3 or THREE. To avoid

Known Error

CR 4482

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Miscellaneous - CONVEX Only - Unacceptable Input Filenames MSC/NASTRAN on the CONVEX will not accept the following filenames:

Description

t.dat at.dat dat.dat

Known Error

CR 4482 Avoidance: Do not use the above names.

Known Error

CR 4484

Product

MSC / MD Nastran

Corrected Version 67.5 Abstract

Cyclic Symmetry - GPFORCE, GPFDR -SFM 3001, FILE 108 NOT IN FIST

Description

Grid point force output is not available in upstream superelements in cyclic symmetry statics (SOLs 81 and 114). A GPFORCE request results in the message "SYSTEM FATAL MESSAGE 3001 FILE 108 NOT IN FIST" being issued from the GPFDR Module. Avoidance: A DMAP avoidance is under investigation.

Known Error

CR 4486

Product

MSC / MD Nastran

Corrected Version GL Abstract

Nonlinear Analysis - Hyperelastic, PLSOLID, FORM=MIXED - No Convergence

Description

When a displacement coordinate system (CD) is specified on any of the grid entries connecting a HEXA hyperelastic (PLSOLID) element, results may either converge slowly or no convergence occurs when FORM=MIXED is selected. Avoidance: Use the default FORM=ISOP.

Known Error

CR 4491

Product

MSC / MD Nastran

Corrected Version 70 Abstract

Description

DMAP - DRMS1 - SFM 4276, EC 7777 The message "SYSTEM FATAL MESSAGE 4276 ERROR CODE 7777" may occur during data recovery of eigenvalues analysis in the DRMS1 module. This error is due to numerical underflow or overflow and is highly machine dependent. This error has only been observed on the DEC VAX(VMS) release of MSC/NASTRAN. Avoidance: Run the job on another machine.

Known Error

CR 4494

Product

MSC / MD Nastran

Corrected Version GL

Known Error

CR 4494

Abstract

Acoustic Analysis - Wrong Answers - SFM 5401

Description

When the surfaces of the fluid cavity are connected to a structural surface containing two or more distinct elements (i.e. the fluid is interfacing with HEXA elements on one surface and QUAD elements on the other surface ) then wrong answers may be produced for the FL./STR. INTERFACE CHECK and/or SFM 5401 may occur. Avoidance : This is a general limitation of MSC/NASTRAN. The acoustic cavity must be surrounded by plate or solid elements but not both.

Known Error

CR 4496

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

Acoustic Analysis - CHACAB - UFM 4422, SFM 4276 EC 7777, Wrong Answers If the table input features of the PACABS Bulk Data entry (TIDi fields) are used to define the reactance for the CHACAB absorber element then, depending on the machine, the job may fail and issue either the message "USER FATAL MESSAGE 4422, NUMBER OF NULL ROWS IN THE DYNAMIC MATRICES IS NOT EQUAL TO THE NUMBER OF NULL COLUMNS" or "SYSTEM FATAL MESSAGE 4276 EC 7777". Incorrect DB pressure values may also be produced. Avoidance: Instead of using the TABLEDi features to calculate the stiffness and mass values for the absorber element, specify the k, m and b values explicitly on the PACABS Bulk Data entry.

Known Error

CR 4498

Product

MSC / MD Nastran

Corrected Version 70 Abstract

Documentation - LINE, MAXLINES - SFM 3019

Description

The message "SYSTEM FATAL MESSAGE 3019 MAXIMUM LINE COUNT EXCEEDED IN SUBROUTINE PAGER LINE COUNT EQUALS ****" is misleading, because the code is actually counting the pages. If the user specifies LINE=X and MAXLINES=Y, then the max number of pages that will be output is Y/X, regardless of how many lines are actually on each page. When the code counts more pages than Y/X, it will issue the message above. If the user specifies a value for LINE that is greater than the actual number of lines per page, then the job fails at a lower line count than MAXLINES.

Known Error

CR 4498 Avoidance: Specify a correct value for LINE.

Known Error

CR 4503

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Case Control - SDR2, MODES - SFM 3002

Description

In MSC/NASTRAN Version 67.5 if the MODES command references an eigenvector that does not exist, the run fails and the message "SYSTEM FATAL MESSAGE 3002 MODULE=SDR2 EOF ENCOUNTERED WHILE READING DATA SET PHG" is output from the SDR2 module. Prior versions of MSC/NASTRAN correctly ignore a MODES command that is beyond the number of eigenvectors calculated. Avoidance: Remove the additional subcase and MODES command.

Known Error

CR 4506

Product

MSC / MD Nastran

Corrected Version 67.5 Abstract

Optimization/Design Sensitivity - UMERGE1 - SFM 4276, EC 1409. If an optimization or design sensitivity analysis contains EPOINTs as is required for the Lagrange multiplier large mass method, then the execution fails in the UMERGE1 module and the message "SYSTEM FATAL MESSAGE 4276 ERROR CODE 1409" is output.

Description

Avoidance: The UMERGE1 DMAP statements at lines 65, 66, and 67 of subDMAP DYNSEN must be ALTERed to set the IOPT parameter to 1 as follows: from: UMERGE USETD,EGMG,,,/EGMP/'P'/'G'/'E' $ to: UMERGE USETD,EGMG,,,/EGMP/'P'/'G'/'E'/1 $

Known Error

CR 4525

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Documentation/Optimization - DEQATN - UFM 201, SFM 217, UFM 224, UFM 5199

Description

Input errors on the DEQATN Bulk Data entry often result in poor messages. The following messages have been encountered when invalid symbols such as a "[" are used or the restriction against large field format is violated on the DEQATN entry: "USER FATAL MESSAGE 215 (PRER2O) BINARY OPERATORS

Known Error

CR 4525 CANNOT BE THE FIRST SYMBOL FOUND IN AN ARITHMETIC LOGICAL EXPRESSION" or "SYSTEM FATAL MESSAGE 233 (PRSPOP) UNDERFLOW OCCURRED DURING PROCESSING OF OPERAND STACK" or "USER FATAL MESSAGE 5199. ON THE ABOVE BULK DATA FREE FIELD CARD AN INTEGER OR A BCD FIELD HAD MORE THAN EIGHT CHARACTERS". Avoidance: Review the requirements of the DEQATN entry documented in the MSC/NASTRAN User's Manual and modify the DEQATN entries as necessary.

Known Error

CR 4528

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Parallel Matrix Methods - SPARSE, PARALLEL - Segmentation Fault

Description

In Version 67.5 of MSC/NASTRAN on the CONVEX C3800 computer, if parallel sparse decomposition is selected, the job fails and no message is printed to the F06 output file. The log file indicates a "Segmentation Fault" error in the routine relcpuu. Avoidance: Presently the only avoidance is to run MSC/NASTRAN within csh and specify the csh command "limit concurrency 4" before execution. The error will be fixed for Version 68 by limiting the maximum number of CPUs to 4 when using parallel sparse decomposition.

Known Error

CR 4529

Product

MSC / MD Nastran

Corrected Version 67.7 Abstract

Description

Sequencer - SEQP, PARAM,NEWSEQ,6 - SFM 4276 FILPOS EC 1044 An error exists in the nested dissection option of the sequencer module. This option is selected by setting PARAM,NEWSEQ,6 in Version 65E, 66, 66A, 66B, 67, or 67.5 of MSC/NASTRAN. The option is also available by setting PARAM,NEWSEQ,8 in Version 67.5 whenever sparse decomposition is also selected. This error causes the job to fail in the SEQP module and the message "SYSTEM FATAL MESSAGE 4276 FILPOS ERROR CODE 1044" to be output. The error occurs only when superelement groups exist in the model and when the number of grid points in any group is more than 1/4 or less than 1/3 of the total number of grids.

Known Error

CR 4529 Avoidance: Other than selecting another sequencer option, there is no avoidance.

Known Error

CR 4536

Product

MSC / MD Nastran

Corrected Version 68 Abstract

DMAP - EQUIV, EQUIVX - UFM 1126 in CALL SELR for datablock FPS (outputtwice) If the EQUIV or EQUIVX statement appears immediately after a CALL statement then the message "USER FATAL MESSAGE 1126" may be incorrectly issued in the subsequent loop. This is an error in the Last-Time-Used (LTU) logic. (Version 67, 67.5 and 67.7 only)

Description

Avoidance: An avoidance is to specify the PARAML module for the offending datablock after the EQUIV (or EQUIVX statement). For example, if UFM 1126 is issued for datablock PS then insert the PARAML DMAP statement as in the following example. CALL XXXX PG/PA,PS $ EQUIVX PA/PA1/-1 $ PARAML PS//'PRES' $

Known Error

CR 4538

Product

MSC / MD Nastran

Corrected Version 68.0.0 Abstract

Nonlinear Analysis - ASETi, OMITi - Poor Message, SFM 2199, UWM 4698 If ASETi or OMITi entries are specified in SOL 66 or 106 and there are no elements with linear material properties, then SFM 2199 and UWM 4698 are issued. This error has been corrected in MSC/NASTRAN Version 68 by issuing the meaninful user fatal message 4423.

Description

Avoidance: This is a user error. The avoidance is to remove all ASETi and OMITi entries since nonlinear degrees of freedom can not be omitted. The correction to SOL 66 and SOL 106 DMAPs results in the meaningful message "USER FATAL MESSAGE 4423 A NONLINEAR ELEMENT IS ATTACHED TO AN OMITTED DEGREE OF FREEDOM" being output.

Known Error

CR 4539

Product

MSC / MD Nastran

Corrected Version 68

Known Error

CR 4539

Abstract

Plotting - NEUPS - Missing Plot Output, Stack Error If a plot file generated by the NEUPS utility can be displayed using the SUN PageView utility or other utilities, but is not able to be printed, then the Postscript file contains too many data points in a single curve and the data overflows the printer's memory. Avoidance: Possible resolutions include: 1. Increase the printer's memory (may not be feasible); or try on other printers, 2. Break a single long curve into a number of curves, 3. Modify the NEUPS utility with the following changes.

Description

In subroutine PLOT, change the following lines: After subroutine plot(x,y,i) Add save strkln After write (unit=ips,fmt=20) x, y,' lineto' Add strkln = strkln + 1 if( strkln.gt.50) then write(unit=ips, fmt=10) 'stroke' write(unit=ips, fmt=10) 'newpath'

Known Error

CR 4543

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

Elements - QUADR - Wrong Answers for Non-Uniform Thickness The corner stress output for the QUADR and TRIAR elements due to membrane forces are calculated and output for the average thickness. Thus the corner stress output for non-uniform thickness elements is wrong. Avoidance: In MSC/NASTRAN Version 67.5, the STRESS(CORNER) option for the QUAD4 element may be used.

Known Error

CR 4545

Product

MSC / MD Nastran

Corrected Version 68 Abstract

File Management Section - INIT SCRATCH, SCR300- UFM 4275

Description

Logical names and their reference to physical files must be unique across all INIT statements. Thus, if both SCRATCH and SCR300 are assigned to the

Known Error

CR 4545 same physical file, then the job may fail and the message "USER FATAL MESSAGE 4275" may be issued. Avoidance: ASSIGN SCRATCH and SCR300 to different files.

Known Error

CR 4549

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Documentation - CTRIAX6, GPWG - Missing Documentation

Description

For the axisymmetric TRIAX6 element, the Grid Point Weight Generator outputs the c.g. for the modeled structure only . The calculated mass is the mass for the entire structure of revolution. This is design intent. This error has been addressed by including a comment under the description of the PARAM,GRDPNT entry in the 2nd printing of the MSC/NASTRAN Version 68 Quick Reference Guide.

Known Error

CR 4551

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Documentation - Application Manual, Section 7.7 - Installation Errors The following documentation errors exist in the Version 67.5 Section 7.7 of the CRAY(UNICOS), CONVEX, and VAX(VMS) MSC/NASTRAN Application Manuals:

Description

1) CRAY(UNICOS) p. 7.7-5 n67ins should be n675ins. p. 7.7-7 %1f should be %1d. 2) CONVEX p. 7.7-5 n67ins should be n675ins. p. 7.7-9 The documentation should say move the nastran.p file and the nastran.man file into the /usr/man/catp directory. p. 7.7-20 nast67 should be nast675. 3) DEC VAX/VMS p. 7.7-14 The documentation on p. 7.7-14 should show "PRT=NO !" instead of "PRT=NO $". p. 7.7-36 5 should be 4 on the Step 5 line. p. 7.7-37 In the Step 7 section, "Steps 2 through 7" should read "Steps 2 through 6" and "Step 4" should be "Step 3"

Known Error

CR 4555

Product

MSC / MD Nastran

Corrected Version

68

Abstract

Documentation - DTIIN - Incorrect User's Manual Documentation The MSC/NASTRAN User's Manual documentation for the DTIIN entry is incorrect. The documentation currently indicates: DTIIN DTI,DTINDX/DTI1,DTI2,DTI3,DTI4,DTI5,DTI6,DTI7,DTI8,DTI9,DTI10/ PARM1/PARM2/PARM3,PARM4,PARM5,PARM6,PARM7,PARM8,PARM9/PARM10 $ This should be changed to:

Description DTIIN DTI,DTINDX/DTI1,DTI2,DTI3,DTI4,DTI5,DTI6,DTI7,DTI8,DTI9,DTI10/ PARM1/PARM2/PARM3/PARM4/PARM5/PARM6/PARM7/PARM8/PARM9/PARM10 $ This error has been corrected in the Version 68 DMAP Module Dictionary.

Known Error

CR 4559

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Miscellaneous - GPSTR1, MODAC2 - Missing Documentation, UWM 4605 The following two user messages have the same number: "USER WARNING MESSAGE 4605. MAXIMUM NUMBER OF MESSAGES HAVE BEEN ISSUED BY GPSTR1 MODULE."

Description

"USER FATAL MESSAGE 4605, INPUT MATRIX **** IS INCOMPATIBLE WITH ITS ASSOCIATED OUTPUT LIST (I.E., TOL, FOL, LAMA, CLAMA)." The latter message is correct since it is the one that is documented in the MSC/NASTRAN User's Manual.

Known Error

CR 4561

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Documentation - OFP - Missing Output

Description

Remark 2 of the MSC/NASTRAN User's Manual description of the OFP DMAP

Known Error

CR 4561 statement states that data blocks can be output by OFP. However, parameter OP1 does not honor data blocks LAMA, OEIGS, LAMX, CLAMA, and OGPWG. This error has been corrected in the Version 68 DMAP Module Dictionary.

Avoidance: There is no known avoidance. Known Error

CR 4563

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Restarts - SUBCOM, CBEAM - Inefficient Restarts When the SUBCOM Case Control command is added to a Structured Solution Sequence (SOL 101 through 200) data recovery restart, and the model contains CBEAM elements, the SEKRRS subDMAP is unnecessarily re-executed in the restart. (V67+ only).

Description

Avoidance: The error may be avoided by using one of the following actions: 1) Use PARAM,SERST,SEDR in the restart run, 2) Replace the SUBCOM with a SUBCASE that references an equivalent load. 3) Use an Unstructured Solution Sequence and perform a manual restart.

Known Error

CR 4572

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Miscellaneous - ACCT - Incorrect label in Accounting file The header of the last field of the MSC accounting file (created by the "acct" keyword) should indicate "Min" not "Sec". Avoidance: The MSC/NASTRAN Version 67.5 script should be changed as follows

Description

Original definition (line 521 on Sun): echo ' ACC3="Monthly-Total-CPU-Sec"'

Change to:

Known Error

CR 4572 echo ' ACC3="Monthly-Total-CPU-Min"'

Known Error

CR 4573

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Aeroelastic Analysis - RESTART - Inefficient Restart

Description

If an M, K aero pair is added to a restart run in Solution 145 or 146, then the existing aerodynamic matrices are unnecessarily recomputed.

Known Error

CR 4574

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Description

Nonlinear Analysis - DBC, ESE - Missing Output On the CONVEX Version 67.5 release of MSC/NASTRAN if a nonlinear analysis contains a request for element strain energy output, then no data recovery output is written to the .XDB file. Avoidance: Remove the ESE request.

Known Error

CR 4575

Product

MSC / MD Nastran

Corrected Version 70 Abstract

Documentation - CQUAD4, PSHELL - Poor Answers A remark should be added to the MSC/NASTRAN User's Manual description of the PSHELL entry. If transverse shear flexibility is specified for a model with curved shells where the loading is dominated by twist, the results for a coarse to medium mesh model may be inaccurate and the results will diverge as the mesh is refined.

Description

Avoidance: MSC/NASTRAN Version 68.2 and later releases include "Shell Normals" an enhancement which corrects this deficiency. This enhancement is documented in the Version 69 Release Guide. Note that by default shell normals are not activated they must be explicitly requested. The Quick Reference Guide description of the CQUAD4 and PSHELL entries should be updated to provide guidance for the above situation. Permanent documentation, not release

Known Error

CR 4575 guides, should

Known Error

CR 4576

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

Material Nonlinear Analysis - NLPCI, RIKS, MRIKS - UWM 6195 When either the RIKS or MRIKS method is used in MSC/NASTRAN Version 67 and later systems, the message "USER WARNING MESSAGE 6195 SOLUTION HAS REGRESSED TO AN EARLIER LOAD STEP" may be issued and the solution will not adapt. Avoidance: Specify the CRIS method on the NLPCI entry.

Known Error

CR 4582

Product

MSC / MD Nastran

Corrected Version GL Abstract

Elements - CMASSi, SEQP- Poor Message, UFM 2012

Description

If a CMASSi entry (and possibly other scalar elements) specify the "0" degree of freedom of a grid point, the job fails and the message "USER FATAL MESSAGE 2012 GRID POINT *** SAME AS SCALAR POINT" is issued. Avoidance: Specify a valid degree of freedom on the CMASSi entry.

Known Error

CR 4584

Product

MSC / MD Nastran

Corrected Version 67.5.0.1 Abstract

Description

Postprocessing - OUTPUT2, PARAM,POST - Segmentation Violation Depending on the machine and operating system level, an error may be encountered when writing very large unformatted OUTPUT2 and OUTPUT4 files. This error causes the message "Segmentation Violation = Signal 11 Code 3" to appear in the log file, with the result that the OUTPUTi files are incorrect. This error has been corrected in Version 67.5.01. Version 67.5.01 is delivered to all new Sun clients and is available on request to all existing clients. This error has been observed on the following hardware/software combinations: MSC/NASTRAN SunOS Version Version Machine Status V67.5 4.1.3 Ver. 3 SparcStation 2 Fails

Known Error

CR 4584 Sparcstation 10 Fails Sparc server

Known Error

CR 4586

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Description

File Management Section - ASSIGN, INIT, - UFM 505 If an FMS statement begins with any blank space, then the job fails and the message "USER FATAL MESSAGE 505 (XCSA) CONTROL CARD 'FMS STATEMENT' IS ILLEGAL" is output. Avoidance: Enter the FMS statement beginning in field 1.

Known Error

CR 4606

Product

MSC / MD Nastran

Corrected Version Abstract

Postprocessing - OUTPUT2 - SFM 1222 If an OUTPUT2 neutral file is created and the ITAPE=-9 option is not used to write an EOF, then the following messages appear in the RCOUT2 job print when converting the file back to binary form: *** SYSTEM FATAL MESSAGE 1222 (LDRTRN) AN UNEXPECTED END OF FILE WAS DETECTED ON A NEUTRAL FILE DURING A DBLOAD OPERATION USER INFORMATION: THIS ERROR TERMINATES PROGRAM EXECUTION AND GENERALLY OCCURS WHEN THE DBUNLOAD JOB FAILS DURING NEUTRAL FILE CREATION USER ACTION: REVIEW NEUTRAL FILE CREATION JOB FOR FATAL MESSAGES

Description *** SYSTEM INFORMATION MESSAGE RC0008 (RCOUT2) THE END-OF-FILE FATAL MESSAGE WRITTEN ABOVE OCCURRED DURING DATA BLOCK NAME PROCESSING. PROGRAMMER INFORMATION: 1. THIS ERROR GENERALLY INDICATES THAT THE LAST OUTPUT2 OPTION USED WAS NOT -9 2. THE OUTPUT2 FORTRAN BINARY FILE CREATED IS CORRECT AND REFLECTS THE CONTENT OF THE NEUTRAL FILE.

Known Error

CR 4606 Avoidance: When creating neutral-format OUTPUT2 files, the -9 option should be used as follows: OUTPUT2 ,,,,//-9/unit number

Known Error

CR 4609

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

Superelements - TEMP(LOAD), TEMP(INIT), RESTARTS - Wrong Answers The following error with thermal loads may occur in restarts with the superelement unstructured Solution Sequences (61-99) or restarts with PARAM,SERST,SEMI (or SEDR) in Solutions 101-200. If the initial temperature is not specified (i.e., TEMP(INIT) is not present) in the initial run (cold start) loads are not generated (i.e., SELG and SELR are not requested), and in the restart run TEMP(LOAD), TEMP(BOTH) or TEMP is specified but no SEMG requests are made (for the superelements processed in the cold start), then the thermal loads are incorrect. This error occurs because the EST data block, which is used in generating thermal loads and depends on the TEMP(INIT), is not regenerated in the restart. It is only generated if SEMG is requested. Avoidance: Specify the same TEMP(INIT) in th

Known Error

CR 4610

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Description

Static Analysis - PARAM,MPCF, PARAM,INREL - UFM 3055 If inertia relief is requested in SOL 101 (PARAM,INREL,-1) in conjunction with "PARAM,MPCF,YES" in MSC/NASTRAN Version 67.5, then the job fails and the message "USER FATAL MESSAGE 3055 AN ATTEMPT TO MULTIPLY OR MULTIPLY AND ADD NON-CONFORMABLE MATRICES TOGETHER WAS MADE IN MODULE MPYAD". This is a version 67.5+ error only. Avoidance: If the model does not contain superelements (i.e., residual only), the following DMAP Alter may be applied to avoid this error: COMPILE SEDRCVR SOUIN=MSCSOU LIST NOREF ALTER 16,16 $ CHANGE PG TO PJ1

Known Error

CR 4610 UPARTN USET,PJ1/PM,,,/'G'/'M'/'N'/1 $ A DMAP avoidance is under investigation for models that contain superelements.

Known Error

CR 4611

Product

MSC / MD Nastran

Corrected Version 67.7 Abstract

Description

DMAP - OUTPUT2, INPUTT2 - Neutral Format, UWM 6444, SFM 1208, SFM 1214 Using the NEUTRAL FORMAT option of OUTPUT2 and INPUTT2 in DMAP may cause the run to fail and issue the following warning and fatal messages: "UWM 6444 (INPTYP) - THE FILE ASSIGNED TO UNIT = CONTAINS DATA THAT IS INCONSISTENT WITH FORM = FORMATTED", "SFM 1208 (LDSTR) - ERROR SETTING UP TRANSLATE TABLE AT LOC = " and "SFM 1214 (LDRTRN) - ERROR TRANSLATING DATA FROM NEUTRAL FILE READ FOR SUBROUTINE LDSTR". Avoidance: Encountering this error is very unlikely and there is no a priori avoidance. If the error is encountered, some possible ways to workaround this problem are as follows: 1. Use the RCOUT2 utility to convert the neutral file to a binary file. Then use the binary option of INPUTT2 to read the file. 2. Rerun the initial OUTPUT2 job with a different neutral record le

Known Error

CR 4612

Product

MSC / MD Nastran

Corrected Version 67.7 Abstract

Description

Postprocessing - OUTPUT2, INPUTT2 - UWM 6444, SFM 1208, SFM 1214, SFM 2190 The INPUTT2 module may fail when attempting to read an input file formatted with the new neutral option in MSC/NASTRAN Version 67.5. Messages that are evidence of this error include "USER WARNING MESSAGE 6444", "SYSTEM FATAL MESSAGE 1208", "SYSTEM FATAL MESSAGE 1214", and "SYSTEM FATAL MESSAGE 2190 (INPTN2) ILLEGAL VALUE FOR KEY". Avoidance: Use the RCOUT2 utility to convert the neutral file to a binary

Known Error

CR 4612 file. Then use the binary option of the INPUTT2 module to read the file.

Known Error

CR 4617

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Miscellaneous - - Missing Completion Time and Date The date and time that MSC/NASTRAN finishes is not printed to the .log file on the DECstation ULTRIX Version 67R2 system.

Description

Avoidance: Line 331 in the ".shl" should be modified. Remove the "exec " command and replace as follows: echo "/bin/time ${LOC_EXE}/${EXE_NAME} ${asgf} {$mem}"

Known Error

CR 4618

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Acoustic Analysis - ACSRCE, CHACAB, PACABS - Wrong Answers, Missing Output If an ACSRCE Bulk Data entry has the same DAREA ID (field 3) for loads applied to structural grid points then wrong answers or missing output may result.

Description

Avoidance: Define a RLOADi or TLOADi Bulk Data entry with an SID (field 2) and DAREA ID (field 3) which is unique with respect to the ACSRCE entry. Then define a DLOAD Bulk Data entry which is referenced by the DLOAD Case Control command and combines the RLOADi (or TLOADi) and ACSRCE entries.

Known Error

CR 4619

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Matrix Methods - SPARSE DECOMP, FBS - Wrong Answers

Description

If the sparse solver and FBS are run more than once and 2 by 2 pivots are necessary for some of the FBS operations, there may be wrong answers. Positive definite matrices do not require pivoting operations. Thus, this error is unlikely in the delivered solution sequences. The DMAP alter RFLAG.V675 delivered with Version 67.5 does not encounter this problem if superelements are not present.

Known Error

CR 4619 Avoidance: Do not use sparse decomposition with alters such as the Lagrange multiplier method that may produce indefinite matrices.

Known Error

CR 4620

Product

MSC / MD Nastran

Corrected Version 67.7.0.1 Abstract

Description

Aeroelastic Analysis - AMG, UFBS, ZONA - Divide By Zero, Missing Data Blocks The supersonic aerodynamic code (ZONA) contained in the Aero II option can fail when the inverse Mach line emanating from a control point of one bax is almost perfectly aligned with the leading edge of another box. On some machines, the error is evidenced by a divide by zero check in the AMG module. On others, it produces missing datablocks in the UFBS module. Avoidance: Experience has shown that a slight change in the requested Mach number (e.g., from M=2.4 to M=2.41) causes the error to go away and good answers result.

Known Error

CR 4621

Product

MSC / MD Nastran

Corrected Version GL Abstract

Plotting - AERO1 - No Plottable Structural Elements Exist If the user desires a plot of only the aerodynamic model and specifies SET 1=AERO1, the following message appears:

Description

NO PLOTTABLE STRUCTURAL ELEMENTS EXIST IN SET 1 Avoidance: Adding any other element to the SET, such as SET 1=AERO1,QUAD4, results in a plot of the aerodynamic model and the elements specified.

Known Error

CR 4623

Product

MSC / MD Nastran

Corrected Version 70.5.2 Abstract

Dynamic Response Analysis - TRD1 - UWM 3045, Poor Message

Description

If a job fails in the TRD1 module due to insufficient time the message "USER WARNING MESSAGE 3045 INSUFFICIENT TIME TO COMPLETE THE REMAINING ** SOLUTION(S) IN MODULE TRD1" is output. This message gives no indication of the amount

Known Error

CR 4623 of time necessary to complete the module. This message is also output by modules AMP, CEAD, FA2, FRRD1, and TRD2. Avoidance: Increase the amount of time on the TIME command.

Known Error

CR 4626

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Documentation - LOAD - Limitation Removed

Description

Remark 6 under the MSC/NASTRAN User's Manual and Quick Reference Guide description of the LOAD entry is no longer applicable. In MSC/NASTRAN Version 66 the limit of 300 Si, Li pairs was removed.

Known Error

CR 4627

Product

MSC / MD Nastran

Corrected Version 67.7 Abstract

Eigenvalue Analysis - EIGRL, LANCZOS - UFM 5429

Description

The time estimated to complete a LANCZOS iteration may be very conservative for large problems. Thus, a run where ample time is specified may inappropriately encounter the message "USER FATAL MESSAGE 5429, INSUFFICIENT TIME TO START LANCZOS ITERATION". Avoidance: Specify a very large value on the TIME entry.

Known Error

CR 4629

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Description

Documentation - Application Manual, Section 7.7.2 - Installation The command "dd if=/dev/extape of=/tmp/MSC675 bs=8b" (documented on page 7.7-2 of the MSC/NASTRAN Application Manual, Version 67.5 for CRAY UNICOS computers) which is to load the file from the delivery tape when an expander tape drive is used, does not work. ` Avoidance: Use the command "dd if=/dev/extape of=/tmp/MSC675 bs=32768" as documented on the same page.

Known Error

CR 4631

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Miscellaneous - Shell Script - Data File Not Found If the name of the .dat file happens to match the beginning of the directory name, and that directory is included in the 1st argument (jid), line 184 of the Convex script file will remove the file name portion from the directory path, and thus the data file will not be found: For example if you have a data file named "abc.dat" in directory /usr1/jones/abc_dir, then submitting a V675 job as: nast675 /usr1/jones/abc_dir/abc will yield: Data file /usr1/jones_dir/abc.dat not found.

Description

Avoidance: Change the the following (line 184) in the script: (add a "\$" sign after the "name") from jid_dir=`echo ${jid} | sed "s;\/$name;;"` to jid_dir=`echo ${jid} | sed "s;\/$name\$;;"` also change the name into nametmp old line: jid_dir=`echo ${jid} | se

Known Error

CR 4634

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Cyclic Symmetry - EIGRL, CYSUP - Wrong Answers

Description

In cyclic symmetry analysis, the Lanczos method of eigenvalue extraction may incorrectly apply "SUPORT" logic which is selected by the CYSUP Bulk Data entry. In one problem, the CYSUP entry resulted in the first eigenvalue of the second Harmonic (a flexible mode) being set to 0 incorrectly. The eigenvector for this mode is correct. Avoidance: Do not use the CYSUP entry with the Lanczos method of eigenvalue extraction.

Known Error

CR 4637

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

DMAP - VECPLOT - Incorrect Matrix Trailer, Wrong Answers When the VECPLOT module is used to generate a matrix containing the geometry of the model, the resulting matrix may have an incorrect trailer value for the number of rows. If this is the case, subsequent modules that use the matrix may fail or give incorrect results.

Description

Avoidance: The following DMAP Alter demonstrates the use of the VECPLOT module to generate a matrix called OUTGEOM with the model geometry and uses the MODTRL module to correct the trailer. VECPLOT ,,BGPDT,EQEXIN,CSTM,,/OUTGEOM/0/3 $ MODTRL OUTGEOM///LUSET $

Known Error

CR 4644

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Acoustic Analysis - PARAM,FLUIDMP - Missing Output The panel participation factors output are missing when the modal participation factors are requested for panels in acoustics, the request is for a selected set of grids, and the model consists of only fluid elements. This error exists in Version 67.5 and 68. Version 67 users should refer to Error 3672 before proceeding. Avoidance: To avoid this error in Version 67.5, apply the DMAP Alter listed below.

Description

COMPILE SEMFREQ SOUIN=MSCSOU NOREF ALTER 125,125 EQUIVX OG/OA/NOA $ IF (NOA>-1) UPARTN USET,OG/OA,,,/'G'/'A'/'S'/1 $ ALTER 148 IF ( FLUIDMP MATGEN ,/FTMP/6/NFEIG/0/FLUIDMP $ PARTN UHFF,,FTMP/,UHFF1,,/1 $ EQUIVX UHFF1/UHFF/-1 $ PARTN PHFA1,FTMP,/,,PHFA2,/1 $ ELSE $ EQUIVX PHFA1/PHFA2/-1 $ ENDIF $ ALTER 155,162

Known Error

CR 4644 To a

Known Error

CR 4654

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Documentation - PARAM,CURVPLOT - Missing SORT1 Output

Description

The documentation for PARAM,CURVPLOT does not indicate that it is a valid parameter for Solutions 71, 72, 111, and 112. This parameter must be specified to obtain SORT1 output in the aforementioned solution sequences. This documentation error is corrected in the 2nd printing of the Version 68 Quick Reference Guide.

Known Error

CR 4655

Product

MSC / MD Nastran

Corrected Version 68 Abstract

DMAP - COMPILE, XREF - Missing Output The MSC/NASTRAN User's Manual for the COMPILE statement states that a cross-reference is available for an NDDL COMPILE. The Version 67 documentation should be amended as follows to indicate the specific circumstances when the NDDL X-REF is available. This capability has been added to Version 68, please see error 2869. [Add to Remark 6.]

Description d. The cross-reference is produced only when the NDDL source is provided directly in the input file. It is not produced when the source is obtained from a SOUIN command. For example, the following two-run sequence produces a cross-reference of NDDLOLD. Note that the cross reference can be large. The cross-reference produced for the NDDL of the Structured Solution Sequences is more than 1000 pages in length. The cross reference for NDDLOLD p Known Error

CR 4656

Product

MSC / MD Nastran

Corrected Version 68 Abstract

DMAP - RESTART, DELETE - Wrong Answers

Description

The DELETE module is skipped in an automatic restart if the datablock(s) to be deleted exist on the database. Note that MSC/NASTRAN's solution

Known Error

CR 4656 sequences use the RESTART module to delete data blocks from the database on a restart run. Thus, this error only affects user DMAPs. Avoidance: Set system cell 109 to 1 before the DELETE and back to 0 immediately after the DELETE. For example, to delete data blocks A and B: PUTSYS(1,109) $ DELETE /A,B,,, $ PUTSYS(0,109) $

Known Error

CR 4663

Product

MSC / MD Nastran

Corrected Version GL Abstract

Old Design Sensitivity - DSCMR - Wrong Answers For large problems (many elements) with many design variables, the DSCMR sensitivity coefficient matrix may have zero values for design variables that should have non zero values of sensitivity coefficients. This problem has been addressed by the solution 200 material sensitivity project in Version 70.7.

Description Avoidance: If the user suspects that there are zero values in the sensitivity coefficient matrix that should be non zero, then reduce the number of design variables requested and compute a new DSCMR matrix.

Known Error

CR 4670

Product

MSC / MD Nastran

Corrected Version 67.5 Abstract

DMAP - DIAGONAL - Missing Documentation

Description

There is no mention in the Version 67 "Nonupward Compatible Features" that the DIAGONAL DMAP module changed and that these changes may result in a nonupward compatibility for user DMAPs. Starting with Version 67, the OPT parameter was changed from BCD to a CHARACTER input. Thus, the values must be enclosed in quotes. If a value is not enclosed in quotes, MSC/NASTRAN interprets the input as a variable and sets the variable to the default value of 'COLUMN'. Since the "Nonupward Compatible Features" for Version

Known Error

CR 4670 67 documentation will not be re-issued, this error is considered addressed with this error report.

Known Error

CR 4677

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Lagrange Multiplier - CVISCi, CDAMPi - Wrong Answers The Lagrange Multiplier DMAP alter delivered in the file RFLAG.V675 in Version 67.5 results in wrong answers for modal frequency response analysis when the models contains viscous dampers. Avoidance: Change RFLAG.V675 as follows:

Description

COMPILE GKAMJR $ $ . . . . skip down about 20 lines, replace following statement $ IF (YES2SET=-1) THEN $ insert next statement in its place IF (false) THEN $

Further client information indicates that this alter still does not work. Known Error

CR 4684

Product

MSC / MD Nastran

Corrected Version Abstract

Description

Nonlinear Analysis - NLEMG - Load Increment is Skipped In solution 106 if param,lgdisp is set to 1 and no nonlinear elements exist, then after a stiffness update the load increment will skip to the next increment. Avoidance: Either add a nonlinear element or place yes in 9th field of the NLPARM entry.

Known Error

CR 4687

Product

MSC / MD Nastran

Corrected Version GL Abstract

Grid Point Stress - GPSTR1, QUAD4, TRIA3, QUAD8, TRIA6 - Wrong Answers

Description

If grid point stress output is requested and the edge point is attached to a linear plate element (QUAD4 or TRIA3), the grid point stress calculation at this edge point may be incorrect. The error only occurs when the other end of the interior line segment connecting to the edge grid is attached to a higher order shell element (QUAD8 or TRIA6). In this case, the stress contribution of the interior grid point is not included in the grid point

Known Error

CR 4687 stress calculation at the edge point. Avoidance: If the edge grid point is connected to a QUAD4 element, then requesting corner output resolves this problem. Unfortunately, corner output is only available starting with Version 67.5. If the edge point is connected to a TRIA3 element or Version 67.5 is not available, then there is no avoidance.

Known Error

CR 4692

Product

MSC / MD Nastran

Corrected Version 67.52 Abstract

Installation - Incorrect File Permissions - No Access Allowed The delivery tape for MSC/NASTRAN Version 67.5 for the CRAY Y-MP (UNICOS) was incorrectly written. In particular, all file permissions for 'other' access are blank, i.e., no access is allowed. The error is corrected for all new installations by the tape labeled "V67.5 MSC/NASTRAN (r2)". Avoidance: The error may be corrected by executing the following commands:

Description

cd /msc # or the actual "repository" directory. cd bin find . -perm 770 -exec chmod 777 {} \; find . -perm 660 -exec chmod 666 {} \; find . -perm 750 -exec chmod 755 {} \; find . -perm 640 -exec chmod 644 {} \; If the repository and installation directories are not the same, execute the following additional commands: cd /msc/nast675 # or the actual "installation" directory find . -perm 770 -exec ch

Known Error

CR 4695

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Grid Point Stress - ELSDCON - Missing GPSTRESS Discontinuity Output, SWM 6247 When requesting grid point stress discontinuities, and more than one type of element is in the surface or volume, the following message is received: "SYSTEM WARNING MESSAGE 6247 (STD2HD/S), THERE IS AN INCONSISTENT

Known Error

CR 4695 POINTER TABLE FOR SCR4 FILE...CHECK POINTER TABLE 5 FOR SCR4 FILE" The run then terminates. Avoidance: Only use one element type in a surface or volume.

Known Error

CR 4696

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Description

Aeroelastic Analysis - SPLINE - UFM 2262 If a SPLINE Bulk Data entry specifies BOX1 and BOX2 or ID1 and ID2 such that there are no aerodynamic boxes splined, the code does not detect the user error. The job will subsequently fail and issue the misleading messages "USER FATAL MESSAGE 2262 (GIPTSD) SPLINE **** INCLUDES AERO BOX INCLUDED ON AN EARLIER SPLINE". Avoidance: Correct the offending SPLINE entry.

Known Error

CR 4700

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Description

Elements - QUAD4(CORNER) - UWM 6418, Missing Output If a Case Control data recovery request is made for QUAD4 corner and center output within the same run, then the message "USER WARNING MESSAGE 6418" is output to warn the user that only one output type is supported per run. The hierarchy of the request that takes precedence is documented in the MSC/NASTRAN Release Notes for Version 67.5. The user warning message contains null characters which may cause some editors to fail and all subsequent output to be missing. Avoidance: Correct the Case Control output requests so that they all request either corner or center output.

Known Error

CR 4701

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Frequency Response Analysis - FRRD1 - SFM 4276, EC 3012

Description

Under unusual circumstances a frequency response run (Solution 26) fails

Known Error

CR 4701 in the FRRD1 module and the message "SYSTEM FATAL MESSAGE 4276 QOPEN ERROR CODE 3012" is issued. This error occurs when there are multiple calls to FRRD1 where the first call solves for a single subcase (load case) or a single frequency and a subsequent call solves for multiple frequencies and multiple subcases (load cases). Avoidance: In Solution 26 the error may be avoided by reordering subcases. The subcases that solve for multiple frequencies and multiple subcases (load cases) must be placed first in the Case Control Section.

Known Error

CR 4703

Product

MSC / MD Nastran

Corrected Version GL Abstract

Nonlinear Transient Analysis - TSTEPNL, TLOAD1 - UFM 4605, Wrong Answers If the "AUTO" method is selected on the TSTEPNL entry for nonlinear transient analysis and the excitation function on the TLOAD1 entry specifies an enforced displacement, then the results are unpredictable. In some cases, the job may fail with the following error message:

Description

USER FATAL MESSAGE 4605. INPUT MATRIX PST IS INCOMPATIBLE WITH ITS ASSOCIATED OUTPUT LIST (I.E., TOL,FOL,LAMA,CLAMA). In other cases, the run may generate wrong answers. Furthermore, the results may not be repeatable from run to run even on the same machine. Avoidance: Use the "ADAPT" method, which is the default method.

Known Error

CR 4707

Product

MSC / MD Nastran

Corrected Version 67.5 Abstract

Description

Restarts - MATi, PCOMP, PELAS - Wrong Answers If a change is made to the upstream superelement structural damping terms (GE field on MATi, PCOMP and PELASi entries), then the structural damping matrix, K4GG is not reassembled to include the upstream structural damping changes. This results in wrong answers in dynamic response solution sequences.

Avoidance: Use Version 67.5 or higher for both the COLD start and RESTART.

Known Error

CR 4707 If you must use Version 67 (or Version 67R2), then insert the following alter which will force K4GG to be reassembled on restart. COMPILE SEMRB SOUIN=MSCSOU NOLIST NOREF ALTER 5 PUTSYS (1,109) ALTER 10 PUTSYS (0,109) ENDALTER

Known Error

CR 4712

Product

MSC / MD Nastran

Corrected Version 68.1 Abstract

Cyclic Symmetry - RESTART - Wrong Answers Restarts to compute modes for additional harmonics does not work correctly. In the RESTART, MSC/NASTRAN calculates the eigenvalues correctly but prints out the eigenvectors for the harmonics from the initial run. Avoidance: To obtain the eigenvectors for the additional harmonics, apply the following alter:

Description

COMPILE MODECYC SOUIN=MSCSOU LIST NOREF ALTER 28 PUTSYS(1,109) $ ...FORCE EXECUTION ALTER 30 PUTSYS(0,109) $ ...RESET ENDALTER COMPILE SEDISP SOUIN=MSCSOU LIST NOREF ALTER 130 PUTSYS(1,109) $ ...FORCE EXECUTION ENDALTER

Known Error

CR 4717

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Superelements - RESTART, SEEXCLUDE - Wrong Answers

Description

The automatic restart logic in the SSS does not recognize the SEEX case control command. If the only change to a model is to attempt to exclude a superelement (or set of superelements) on a restart, then the program does not perform the necessary operations and the answers from the original

Known Error

CR 4717 run are used. Avoidance: Make a change to the superelement immediately downstream from the superelements affected by the SEEX command. For example, add a disjoint GRID point to the downstream superelement. The automatic restart logic then reprocesses the downstream superelement and correctly processes the SEEX command.

Known Error

CR 4718

Product

MSC / MD Nastran

Corrected Version 68 Abstract

File Management Section - DBUNLOAD - Infinite CPU Loop Attempting to DBUNLOAD a data block in the neutral format that is not defined in the NDDL may result in the program entering an infinite CPU loop.

Description Avoidance: Do not use the DBUNLOAD neutral option when outputting nonNDDL data blocks. Known Error

CR 4721

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Description

Miscellaneous - Shell Script Error - Unidentified Keyword on IBM RS/6000 An error exists in the IBM RS/6000 operating system that causes the NASTRAN shell script to incorrectly translate keywords resulting in an "unidentified keyword" error message being output during submittal of the NASTRAN job. The problem lies with the translate function. If a keyword is specified in uppercase in the nast675rc file, then it will be transposed by one character. The following example of the "tr" command illustrates the error: echo "FrEd" | tr '[a-z]' '[A-Z]' gRfD Thus, the valid keyword SDIR is translated to "tejs" and an unidentified keyword entry error results. Avoidance: This error may be overcome by using the "tr -A" option.

Known Error

CR 4723

Product

MSC / MD Nastran

Corrected Version GL Abstract

Documentation - OUTPUT2, RCOUT2 - Poor Message, SFM RC0005 The OUTPUT2 neutral option is driven by the NDDL description for the datablock to be neutralized. An incorrect NDDL description results in the following FATAL message during the RCOUT2 run.

Description

0*** SYSTEM FATAL MESSAGE RC0005 (RCOUT2) ILLEGAL KEY VALUE DETECTED USER INFORMATION: EXPECTED KEY VALUE: GREATER THAN OR EQUAL TO 2 DETECTED KEY VALUE: -3 FATAL ERROR CODE - INVALKEY 0004 FATAL ERROR Although the consequences of attempting to output a non-NDDL data block using the neutral option is not documented, the MSC/NASTRAN Release Notes for Version 67.5 clearly documents that only NDDL data blocks may be output with the neutral option. Avoidance: The new documentation for OUTPUT2 in Appendix C of the MSC/NASTRAN Release N

Known Error

CR 4727

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Description

Optimization/Design Sensitivity - FRRD2 - Inefficient Decomposition In frequency response, SOL 200, module FRRD2 may do unsymmetric decomposition when symmetric decomposition should be used. Although answers are unaffected, the processing is inefficient.` Avoidance: There is no avoidance.

Known Error

CR 4730

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Nonlinear Analysis - PUNCH, SORT2 - Missing Labels

Known Error

Description

CR 4730 In Solution 66 and 106 grid ids and element ids are missing from the punched output file whenever SORT2 output is requested. The missing element ids and grid ids may be obtained in Version 69 by specifying system(210)=1.

Avoidance: There is no avoidance.

Known Error

CR 4731

Product

MSC / MD Nastran

Corrected Version 67.5 Abstract

Description

Miscellaneous - Shell Script - Incorrect Accounting On earlier maintenance levels of AIX 3.2, the date(1) command changed its default output format - the command no longer displayed the time zone. As a result, the information written to the accounting file is missing the time zone. This results in all items on the line after the time zone to be misinterpreted. This is manifested in the accounting file by the last two fields on each line doubling with each run until the dc(1) command blows up and corrupts the accounting file. This error is present at AIX 3.2.0, it may also be present at level 3.2.1. The error is corrected at AIX 3.2.2 and above. Avoidance: Upgrade to AIX 3.2.2 or beyond. The accounting file may be corrected by deleting the lines which do not match the fourteen field format described in the header of the file.

Known Error

CR 4734

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Miscellaneous - STRSORT, PARAM,S1G - Stress Output Not Sorted

Description

When PARAM,S1G,1 is specified, the stresses at the grid points are not sorted as requested. The stresses are output in the order of the grid IDs. Avoidance: There is no known avoidance.

Known Error

CR 4737

Product

MSC / MD Nastran

Corrected Version 67.0.1

Known Error

CR 4737

Abstract

Optimization/Design Sensitivity - BUCKLING, MDCASE - Missing Output

Description

On the CRAY C-90 MSC/NASTRAN Version 67.7 system, no data recovery results will be output for the buckling subcase of a design optimization/sensitivity analysis. This error has been corrected for the residual structure in the Version 67.7.0.1 system.

Known Error

CR 4740

Product

MSC / MD Nastran

Corrected Version 67.5 Abstract

Security - Authorization - SGI(Challenger), OS 5.0.1 The usual "sysinfo -s " command as documented in Section 7.7 of the MSC/NASTRAN Application Manual for SGI Computers does not return a correct machine ID under Version 5.0.1 of the IRIX operating system.

Description

Avoidance: Log on as superuser and enter the following commands: systune -i $ this takes you into the Kernel tuning tool use_old_serialnum 1 exit then use auto config and reboot. After doing this, sysinfo -s will return the correct ten-digit serial number.

Known Error

CR 4741

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Description

Composites - PCOMP - Infinite CPU Loop When modeling a sandwich or honeycomb structure with PCOMP and MAT1 entries, setting the modulus of elasticity E to 0.0 for the core's material may result in MSC/NASTRAN entering an infinite CPU loop on some computers. In MSC/NASTRAN Version 68 USER FATAL MESSAGE 6662 is issued if the modulus of elasticity is entered as zero. Avoidance: Set E to a relatively small value or use a MAT2 entry with relatively small Gij's to model the core.

Known Error

CR 4747

Product

MSC / MD Nastran

Known Error

CR 4747

Corrected Version 68 Abstract

Documentation - DPHASE- Frequency Response Analysis

Description

Remark 5 on page 411 of the MSC/NASTRAN Quick Reference Manual and page 2.4-204 of the Version 67 MSC/NASTRAN User's Manual for the DPHASE Bulk Data entry should be deleted. DPHASE entries can be applied to loads generated by the LSEQ entry in frequency response analysis.

Known Error

CR 4748

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

Miscellaneous - IFP - No Error Message The character type and other input types of fixed field Bulk Data input are designed not to allow embedded blanks and they must lie completely within the designated field. If any embedded blanks occur within any input, a UFM 300 message is to be issued. However, if the embedded blank(s) are preceded by the characters D, E, + or -, then MSC/NASTRAN does not detect the input error. MSC/NASTRAN will combine the 2 fields into a single input data. Two examples follow. The input error in the first example is correctly fielded by MSC/NASTRAN by issuing USER FATAL MESSAGE 300. The input error in the second example is not correctly fielded, and in this case a character string of "PID 9" is assigned to LABEL. . 1 .. 2 .. 3 .. 4 .. 5 .. 6 .. 7 .. 8 . DVAR

Known Error

CR 4750

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Optimization/Dynamic Sensitivity - LSEQ - SFM 4276, EC 3001 If multiple LSEQ entries are used in a dynamic sensitivity analysis, the job fails and the following error message is output:

Description

SYSTEM FATAL ERROR 4276.GREAD ERROR CODE 3001 Avoidance: Reference all loads on a single LSEQ entry.

Known Error

CR 4752

Product

MSC / MD Nastran

Corrected Version GL

Known Error

CR 4752

Abstract

Nonlinear Analysis - MPC, MCE1 - Inefficient Restart If there are multiple subcases in a nonlinear statics restart run, and there are MPCs in the model, the MCE1 module is reexecuted for each subcase. This is true even if the MPCs are not modified from the coldstart run. If the MPC is not changed on the restart run, the MCE1 module should only be reexecuted for the first new subcase. This is because the transformation matrix between the m and n sets is not saved in the cold start run. Subsequent subcases should not reexecute the MCE1 module unless the MPC has been changed.

Description Avoidance: If the restart run has more than one new subcase and the MPC has not changed from the coldstart run, then insert the following DMAP alters to avoid this situation: COMPILE NLSTATIC,SOUIN=MSCSOU,NOLIST,NOREF ALTER 13 $ TYPE PARM,,I,N,FIRST=0 $ ALTER Known Error

CR 4753

Product

MSC / MD Nastran

Corrected Version 67 Abstract

Description

Old Design Sensitivity - BUFFSIZE - Possible Wrong Answers On the SUN and possibly other machines, if the old dynamic design sensitivity capability is used and a non-default buffsize is specified, then the sensitivity coefficients may be wrong. This problem has been observed on the SUN computer for very large problems. The only obvious indication of an error is that different sensitivity coefficients for the same design variables may be obtained by using different sets on the SET2 entry. Avoidance: Use the default BUFFSIZE.

Known Error

CR 4758

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Nonlinear Analysis - DBC - SWM 6065, Wrong Answers in the XDB

Description

In a nonlinear analysis, if the model contains more than one element type (e.g., QUAD4 and TRIA3) and "PARAM,POST,0" is used, then the results in the graphical database (xdb) may be incorrect. This error has no effect on the printed results in the F06 file. If this error occurs, then the

Known Error

CR 4758 following messages appear in the F06 file. This error occurs in all Version 67.5 systems. SYSTEM WARNING MESSAGE 6065 (DBC) DBCMSG ERROR MESSAGE 23 FROM SUBROUTINE GRIDBK OUTPUT LIST SYNCHRONIZATION PROBLEM FOR NLLF VALUE = xxx , POSITION = y SYSTEM WARNING MESSAGE 6065 (DBC) DBCMSG ERROR MESSAGE 23 FROM SUBROUTINE ELMBLK OUTPUT LIST SYNCHRONIZATION PROBLEM FOR NLLF VALUE = xxx , POSITION = y Avoidance: Request displacement output for at least one grid point for all sub

Known Error

CR 4760

Product

MSC / MD Nastran

Corrected Version 67.7.0.1 Abstract

Description

Acoustic Analysis - ACMG - Wrong Answers, SFM Acoustic models that have structural interface points with an output coordinate system defined other then the basic, fails with a floating point error in module ACMG or produce incorrect answers. Note that this error is not repeatable on any other machine. It is also not repeatable in V67R2 CRAY YMP. Avoidance: Do not specify an output coordinate system.

Known Error

CR 4765

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Heat Transfer - RF61D01, PARAM,HEATSTAT - Poor Answers

Description

There is an error in the stiffness matrix formulation for the QUAD4 element, which only occurs after the approach is changed during the same execution. The two possible approaches are heat transfer and structural analysis. Different Gauss integration locations have been chosen for each approach. If the approach is changed, and the executable is not reloaded, then wrong locations are used. The effect is answers of less accuracy. In Version 64 and earlier releases of MSC/NASTRAN, frequent link switches avoided this error. In Version 65 and higher, this error only occurs in SOL 61 (with RF61D01),

Known Error

CR 4765 SOL 101 (with PARAM HEATSTAT) and user DMAPs which change SYSTEM(56). Avoidance: There is no user avoidance which allows QUAD4's to have both approaches in one execution. If QUAD4's are needed,

Known Error

CR 4766

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Description

Documentation - Installation Script - Soft Link Not Redefined If there is an existing 'nastran' or 'emas' command (soft link) in /usr/bin, the ninstall and einstall scripts will not redefine the command. Thus, users will execute the previous version of MSC/NASTRAN or MSC/EMAS instead of V67.5 or V2.5 This problem occurs on all 67.5, 2.5 UNIX platforms except SGI and INTEL. Avoidance: Manually redefine this soft link to point to {install directory}/bin/nast675,emas25.

Known Error

CR 4768

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Description

DMAP - ACQUIRE NDDL - Poor Performance, Missing Timing Constants When a user creates a user DMAP, the original design intent was that the user DMAP would automatically acquire the NDDL of the structured solution sequences unless a user supplied NDDL was provided with the DMAP or an ACQUIRE NDDL=NDDLOLD or an ACQUIRE NDDL=UserNDDL was used. In MSC/NASTRAN Version 67.5 this automatic acquire of NDDL=NDDL was inadvertently removed. This is an inconvenience to the user but more importantly the user who does not think he or she needs any data base access and hence does not need any NDDL for the user supplied DMAP will not acquire the appropriate timing constants that reside on the delivery data base. Avoidance: The user must explicitly specify an ACQUIRE NDDL entry.

Known Error

CR 4769

Product

MSC / MD Nastran

Corrected Version 68 Abstract

DMAP - MESSAGE Module - Trap encountered

Description

On the IBM RS 6000, if the MESSAGE Module is used, the job may fail with

Known Error

CR 4769 the following error messages in the log file. Trap encountered, Traceback: Offset 100043c8 in procedure Offset 3cc in procedure xtrac2_ Offset 324 in procedure semtrn_ Offset 6c in procedure semint_ Offset 48 in procedure xsem01_ Offset e4 in procedure mainal Offset 0 in procedure start Both the F06 and F04 files may be incomplete. This error is encountered if the MESSAGE statement spans more than one line and the first value (Pi) on the continuation line starts with a blank string ' '. An example of such a situation is as follows: MESSAGE // ' '/'User information message,'/ ' '/' this is a test'/ $ Avoidance: Replac

Known Error

CR 4773

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Nonlinear Analysis - RFORCE/LOAD - Wrong Answers

Description

In a nonlinear analysis, if the RFORCE is referenced by a LOAD or DLOAD entry, and the scale factor on the is not equal to one, then the loads are be generated incorrectly. This error leads to wrong answers. Avoidance: Reference the loads directly on the RFORCE entry.

Known Error

CR 4774

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Description

Documentation - PARAM,NMLOOP - SFM 3001, UWM 8592 In SOL 106, normal modes will be computed with the updated nonlinear stiffness by using PARAM,NMLOOP. The description of NMLOOP on page 787 of the Quick Reference Guide Version 67 and page 3.1-50 of the User's Manual should read: This option requires the presence of a METHOD

Known Error

CR 4774 command in the Case Control Section within or above SUBCASE 1 that references an EIGR or EIGRL entry in the Bulk Data. If the METHOD command is put in the Case Control after SUBCASE 2, the following messages are issued: "SYSTEM WARNING MESSAGE 3001 - ATTEMPT TO OPEN DATA SET 105 IN SUBROUTINE REIG, WHICH WAS NOT DEFINED IN THE FIST." and "USER WARNING MESSAGE 8592, (REIG). THE METHOD RECORD IN CASE CONTROL IS MISSING OR INCORRECT. THIS WILL CAUSE THE FOLLOWING FATAL ERRORS. USER ACTION: PUT

Known Error

CR 4775

Product

MSC / MD Nastran

Corrected Version 66 Abstract

Miscellaneous - LORY Codes Inoperatble on VAX V65 and V65C

Description

LORY security codes do not work for VAX V65 and V65C. If the need for a LORY security code arises, please make a request for V65Z on the VAX which has corrected this error.

Known Error

CR 4782

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Documentation - RSPLINE - Inconsistent results. There are two undocumented rules for the RSPLINE element.

Description

The order of the grids on the RSPLINE entry affects the constraint coefficient (RMG) matrix in all solution sequences. The sequence of the grid identification numbers should appear in the same order as the line that joins the two mesh regions. If this order is not followed then the RSPLINE will have folds in it that may yield some unexpected interpolation results. The component R3, i.e., degree of freedom 6, of the independent grids on the RSPLINE should not normally be constrained. This restriction is discussed in a July 1982 Application Note entitled: "Interfacing Finite Element Models and Constraint Elements".

Known Error

CR 4785

Product

MSC / MD Nastran

Known Error

CR 4785

Corrected Version 68 Abstract

Documentation - TYPE - Unexpected Results

Description

Although it is not documented, the 'TYPE' DMAP statement is positional. It must occur before the first use of any datablocks listed on the TYPE statement. If any referenced datablocks are defined as output before the TYPE statement, they are replaced with what is on the database (usually nothing, since they haven't been defined as database datablocks yet). This may result in unexpected results.

Known Error

CR 4790

Product

MSC / MD Nastran

Corrected Version 67.7.0.2 Abstract

Description

Eigenvalue Analysis - EIGRL - UIM 4158, SFM 5401 If the V1 field on the EIGRL entry is left blank, the Lanczos eigenvalue extraction method may fail to find all the desired eigenvalues in the range. This error occurs when the decomposition of the dynamic matrix fails as the result of ill-conditioning and the message "USER INFORMATION MESSAGE 4158, MAXIMUM RATIO OF MATRIX TO FACTOR DIAGONAL = ** AT ROW NUMBER **" is issued. The Lanczos method then tries to correct the ill-conditioning problem changing the shift eigenvalue. Large negative shift values result and the job subsequently fails and the message "SYSTEM FATAL MESSAGE 5401 (REIGL). LANCZOS METHOD IS UNABLE TO FIND ALL EIGENVALUES IN RANGE" is output. Avoidance: Specify V1 on the EIGRL entry as a small negative number.

Known Error

CR 4793

Product

MSC / MD Nastran

Corrected Version 68 Abstract

DMAP - COMPILE, RF3D66 - SFM 9876, OC4 When compiling DMAP alters in the USS in versions 66 thru 67.5, it is possible to get an 0C4 error. The problem occurs in subroutine COLD.

Description

Avoidance: The problem does not occur in the SSS. The following ZAP will correct the error in the USS: //ZAP EXEC PGM=AMASZAP //SYSPRINT DD SYSOUT=* //SYSLIB DD DISP=OLD, DSN=...Library with MSC/NASTRAN MSP-EX modules...

Known Error

CR 4793 //SYSIN DD * NAME NASTRAN COLD VER 0E4C 5830,D118,8930,0002,58F0,D530,5823,F008 CHECKSUM A49F9273 VER 0E5C 58E0,D504,502E,A01C,580E,A010,5900,6028 CHECKSUM 83B55A1C VER 0E6C 4770,DBFC,507E,A01C CHECKSUM 8A8497EE REP 04EC 58E0,D504,1827,580E,A010,5900,6028,4780 CHECKSUM A0D18242 REP 0E6C F008,0700,502E,A01C CHECKSUM B5894036 IDRDATA COLD-0C

Known Error

CR 4795

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Nonlinear Analysis - NLPARM, INTOUT - No Warning Message

Description

The only acceptable entries for the INT field on the NLPARM entry are YES, NO, or ALL. If any other strings are entered in this field, then the program uses the default of NO and no intermediate output is produced. Avoidance: Enter one of the three valid entries.

Known Error

CR 4800

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Documentation - Incorrect Command in Install Manual., Application Manual 7.6-7.7 The command documented to retrieve the nastran or emas installation script from a remote tape device is not valid on the HP. Specifically, the option "B" is not a valid option and causes the tar command to fail.

Description

Avoidance: Do not specify the "B" option. This allows the user to perform a remote installation of the installation script; however, the script must be modified to complete the installation with the following UNIX commands: sed 's/rsh /remsh /;s/xvfB/xvf/' < ninstall >ninstall.hp chmod a+x ninstall.hp Then execute this new script, i.e. ./ninstall.hp. The same commands are to be used for a remote MSC/EMAS V2.5

Known Error

CR 4800 installation substituting einstall for ninstall.

Known Error

CR 4816

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Installation - - /usr/local/mscrc not found

Description

The user may encounter the message "/usr/local/mscrc not found" while installing MSC/NASTRAN Version 67.5. Avoidance: Create /usr/local directory.

Known Error

CR 4823

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Matrix Methods - FBS - SFM 4276, EC 7777 Regular (non-sparse) FBS may fail if the following conditions are true: 1. Multiple passes are required. 2. Either the right-hand side matrix is an identity matrix or the right hand side matrix is complex and the factor matrix is real.

Description

Typically, the symptom of this error is a "SYSTEM FATAL MESSAGE 4276, EC 7777" being issued from the FBS module. This error is most likely to occur when executing frequency response with the mode acceleration method of data recovery (PARAM,MODACC) since this analysis can produce a large complex matrix as input to FBS for the right-hand side. Avoidance: Use the sparse method or increase the memory size.

Known Error

CR 4824

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Description

Random Response Analysis - QUAD4(CORNER) - SWM 3002, Missing Output A random analysis request of QUAD4 corner stress output results in the message "SYSTEM WARNING MESSAGE 3002, MODULE=RANDOM EOF ENCOUNTERED WHILE READING DATA SET OES2 (FILE 107) IN SUBROUTINE RAND2" being output. Avoidance: Other than requesting center stress output and performing the

Known Error

CR 4824 random analysis on the center stresses, there is no avoidance.

Known Error

CR 4825

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Installation - Application Manual, Section 7.7 - HP 9000 Version 67.5 Only

Description

Section 7.7 of the MSC/NASTRAN Application Manual for HP 9000/700 computers refers to /dev/update.src as the standard tape device name. The device name currently used is /dev/rmt/0m.

Known Error

CR 4827

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Complex Eigenvalue Analysis - CEAD - Wrong Answers The complex eigenvalue solution to a two dof problem with structural damping (no viscous damping) will result in incorrect answers for all extraction methods except INV. This problem is limited to two dof systems with no viscous damping, one dof and three dof or greater problems produce correct answers. Avoidance: Include a small viscous damper in the analysis set.

Known Error

CR 4829

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Description

Optimization/Design Sensitivity - DVPREL2, DESVAR - Wrong Answers If a design variable value defined on a DESVAR entry or a second level model property defined on a DVPREL2 entry is less than 1.E-3 in magnitude, wrong answers occur. Avoidance: Rescale the model so that the second level model property is greater than 1.E-3.

Known Error

CR 4830

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Restarts - SYSTEM(148) - UFM 1215

Description

Databases created with MSC/NASTRAN Version 67 are compatible with MSC/NASTRAN

Known Error

CR 4830 Version 67.5 and the intent is that SYSTEM(148)=1 should not be required to restart from a Version 67 database into Version 67.5. An error on the CRAY Y-MP UNICOS Version 67.5 requires that this system cell be set to avoid the message "USER FATAL MESSAGE 1215 (CKRVER) THE PRIMARY DATABASE IS INCOMPATIBLE WITH THIS VERSION OF THE PROGRAM". Avoidance: When restarting from a Version 67 database, specify NASTRAN SYSTEM(148)=1 in the input file for the CRAY Y-MP UNICOS system.

Known Error

CR 4832

Product

MSC / MD Nastran

Corrected Version GL Abstract

Plotting - XYPLOT - Erratic Plot Output When using XYPLOT, if the largest value to be plotted (YMAX) is approximately (but not exactly) equal to the smallest value (YMIN), the plot may appear erratic. This is due to the plotter scaling the range to fill the plot.

Description Avoidance: Set YMIN and YMAX with plotter commands a reasonable distance apart. Known Error

CR 4834

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Documentation - TABDMP1, SDAMP

Description

In the User's Manual, equation 7 on page 1.6-4 indicates that the value of "g(i) is obtained by interpolation of a table supplied by the user" on the TABDMP1 entry. This statement is true but is incomplete for type "CRIT" and "Q" damping. For these types of damping the value of g(i) is obtained by interpolation from the TABDMP1 entry and the value is converted by the program to type "G" damping. The MSC/NASTRAN Version 68 Dynamics User's Guide discusses damping in depth. Thus, this error is considered corrected in Version 68.

Known Error

CR 4843

Product

MSC / MD Nastran

Corrected Version 69.1 Abstract

Superelements - SEQSET - SEP2 Logic Error 607, Poor Message

Description

In a superelement model, if the SEQSET dof's for one superelement are

Known Error

CR 4843 placed interior to a superelement at the same level in the tree (or in a different branch of the tree), a SEP2 LOGIC ERROR 607 occurs. Avoidance: Degrees of freedom used for the SEQSET of a superelement must belong to a downstream superelement in the same branch.

Known Error

CR 4846

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Description

Optimization/Design Sensitivity - TRIAX6 - Poor Message, SFM 4276, EC 1044 TRIAX6 elements are not supported in shape sensitivity. If TRIAX6 elements are present in a shape sensitivity analysis the message "SYSTEM FATAL MESSAGE 4276 QOPEN ERROR CODE 1044" is issued from the DOMCO2 module. Avoidance: There is no avoidance.

Known Error

CR 4851

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Documentation - Application Manual 7.6 - Wrong Maximum BUFFSIZE

Description

The MSC/NASTRAN Application Manual, Version 67.5 for CONVEX computers incorrectly documents the maximum allowable BUFFSIZE as 17921. The correct maximum value is 65537.

Known Error

CR 4854

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Documentation - DEQATN - Incorrect Size Limitation

Description

The number of allowable characters for the DEQATN entry was increased in MSC/NASTRAN Version 67 and error number 3284 cited this enhancement. However, the MSC/NASTRAN Version 67 User's Manual and Quick Reference Guide were not updated to reflect the change. The current number of allowable characters is approximately 5000. This is equivalent to approximately 65 card images. The MSC/NASTRAN Version 68 Quick Reference Guide documents the latest limit which is 12,500 characters.

Known Error

CR 4855

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Heat Transfer Analysis - SPARSE, SSGHT - SFM 3007

Description

Although it is intended for the sparse solver (NASTRAN SPARSE=25) to work in heat transfer analysis in MSC/NASTRAN Version 67.5, heat transfer data decks executed with the sparse solver fail and issue the message "SYSTEM FATAL MESSAGE 3007, ILLEGAL INPUT TO SUBROUTINE" in module SSGHT. Avoidance: Do not use the sparse solver in heat transfer solutions (SOL 153).

Known Error

CR 4856

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Documentation - Reference Manual, Plotting - Incorrect Coordinate System

Description

Page 4.2-17 of the MSC/NASTRAN User's Manual incorrectly states that X,Y,Z components of displacement are CONTOUR plotted in the global coordinate system. The default for the displacement CONTOUR plots is the Basic coordinate system.

Known Error

CR 4860

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Documentation - Application Manual, User Modifiable - SUN4, IBM RS/6O00 Only

Description

The instruction that states "copy the nastran shell script into a file umn675" in Section 7.6.7.3 of the SUN4 and IBM RS/6000 MSC/NASTRAN Application Manuals should read "copy the nastran shell script into a file nastumn675". The shell script must begin with the letter "n" as this letter is used internally with the shell script to distinguish between a NASTRAN and EMAS execution.

Known Error

CR 4862

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract Description

Elements - CRAC2D, CRAC3D - Wrong Answers The CRAC2D and CRAC3D elements are extremely sensitive to aspect ratio effects. An aspect ratio of even two to one results in wrong answers.

Known Error

CR 4862 Avoidance: When using the CRAC2D or CRAC3D element keep the aspect ratio at or very near one to one.

Known Error

CR 4867

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Documentation - Version 67.5 Release Notes - Missing Documentation

Description

At least one client's Version 67.5 delivery package contained two copies of the MSC/NASTRAN Common Questions and Answers for Version 67.5" manual but did not contain a copy of "MSC/NASTRAN Release Notes for Version 67.5". The release notes are a critical document for understanding the enhancements for Version 67.5. If your delivery is missing this document, please contact your local representative and request a copy be sent. The delivery letter in future releases of MSC/NASTRAN will contain a contents list so that client's can quickly ascertain if there are any missing materials.

Known Error

CR 4868

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Description

Elements - HEXA, PENTA, TETRA - Principal Stresses sort problem The output for solid element principal stresses is not sorted well in all cases. The element output principal stresses should be sorted with the largest first (major), the smallest second (minor), and the middle last (second major). However, if two of the principal stresses are the same value, the first principal will be the unique one and the other two will be the ones that are the same, regardless of the relative values of each. The .xdb file and the OUTPUT2 file of the output table also contains this output order. Thus, postprocessors, including MSC/XL, read the principals as they are written and assume that they are in the major, minor, 2nd major order and the resulting plots can be wrong. Avoidance: There is no avoidance.

Known Error

CR 4870

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Miscellaneous - OUTPUT2 - UIM 1206, Missing NDDL Descriptions

Description

Some datablocks which are described in the NDDL for the Structured

Known Error

CR 4870 Solution Sequences (SSS) are not described in the NDDL for the Unstructured Solution Sequences (USS). If the neutral option on the OUTPUT2 statement is to be used for these datablocks, the NDDL_NAME must be specified. Note that this is a Version 67.5 plus capability. MSC/NASTRAN Version 68 includes the correct NDDL description for the USS for all the data blocks noted below except ONRGY1. List of known datablocks; Datablock NDDL_NAME OES1 OES OES2 OES OEF2 OEF OPG2 OPG OQG2 OQG ONRGY1 ONRGY OSTR2 OES

Known Error

CR 4872

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Nonlinear Transient Analysis - RBE2 - Wrong Answers for SPCFORCES Nonlinear Transient Analysis that contain RBE2 elements with grounded independent degrees of freedom produce wrong answers for the SPCFORCE output.

Description Avoidance: Remove the RBE2 element and constrain the dependent degree of freedom directly. Known Error

CR 4879

Product

MSC / MD Nastran

Corrected Version 67.7.0.3 Abstract

Frequency Response Analysis - FRRD1A - Wrong Answers

Description

Frequency Response Analysis may produce wrong answers on all CRAY C90 and later CRAY Y-MP systems that have split memory. This includes all Y-MP/8I, Y-MP/4E and some Y-MP/2E systems. The error can occur in Version 67R2, 67.5 and Version 67.7 and has been caused by a bad coding practice and a change in the later version of the CRAY FORTRAN compiler. The error is dependent

Known Error

CR 4879 on the manner in which the frequency dependent load is defined and can only occur if the following three conditions are met: 1. DLOAD entries are in the bulk data 2. Total number of (RLOAD1's, RLOAD2's, TLOAD1's, and TLOAD2's) > number of DLOAD's + 5 3. Total number of (RLOAD1's, RLOAD2's, TLOAD1's, TLOAD2's and DLOADs) = An odd number Avoidance: Avoid one of the three conditions mentioned by adding dummy en

Known Error

CR 4880

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Parallel Matrix Methods - SYSTEM(107), PDCOMP, DOTRD - Poor Answers Parallel decomposition may produce poor answers on large problems on the IBM MVS/XA Version 67.5.1 release of MSC/NASTRAN running in Vector mode.

Avoidance: Either do not run with vector, do not select parallel decomposition, or apply the ZAP to correct the problem: Description

//ZAP EXEC PGM=AMASPZAP //SYSPRINT DD SYSOUT=* //SYSLIB DD DISP=SHR,DSN=..nastran load library.. //SYSIN DD * NAME NASTKVCT KERNVCT1 VER 09F6 1200,4780,F10A REP 09F6 47F0,F10A,0700 /*

Known Error

CR 4881

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Optimization/Design Sensitivity - DVPRELi, DESVAR - UFM 6421

Description

In MSC/NASTRAN Version 67.5 solution 200, if the initial property value as specified from a DVPRELi entry is the same as PMIN on the DVPRELi entry, then due to machine roundoff the job may fail and issue the message "USER

Known Error

CR 4881 FATAL MESSAGE 6421 (DOM11A)" that indicates that the property value is less than PMIN on the DVPRELi entry. In an attempt to correct this error in Version 67.7.1, errors were introduced. The first error occurs whenever a PMIN value is less than the designed property value, but both values round to the same integer. This case should result in a user fatal message but does not. The second error may result in an integer overflow and the third error may cause the final design to violate the minimum property constraint by as much as 1.0 unit. The significance of this e

Known Error

CR 4883

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

Differential Stiffness and Buckling - QUADR - Wrong Answers The QUADR and TRIAR elements do not support differential stiffness as is documented in the User's Manual. Therefore, they should not be used for buckling analysis. User Warning Message 5481 will be issued when either one of these elements is used in a buckling analysis. However, if the QUADR is used in a buckling analysis, an incorrect rather than a null differential stiffness will be generated and wrong answers occur. Avoidance: Do not use QUADR or TRIAR for buckling analysis. Replace them with the QUAD4 and TRIA3 elements

Known Error

CR 4884

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Differential Stiffness and Buckling - No output request - Wrong Answers If no data recovery is requested in solution 105 in the static subcase, then the eigenvalue calculation will be wrong.

Description

Avoidance: Request data recovery in the static subcase. A request for DISP(PLOT)=ALL avoids unwanted output in the F06 file and still avoids the error.

Known Error

CR 4885

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Cyclic Symmetry - RESTART, GRAV, RFORCE, LOADCYH - Missing Loads, Wrong Answers

Known Error

CR 4885 In solution 114, if a coldstart run defines GRAV and RFORCE loads in the bulk data but the loads are not referenced, then the GRAV and RFORCE loads are missing in a subsequent restart that references them.

Description Avoidance: Coldstart any cyclic symmetry run that references GRAV and RFORCE loads, or add a dummy CMASSi to the restart deck to force the recalculation of the mass matrix and the regeneration of the inertia loads. Known Error

CR 4888

Product

MSC / MD Nastran

Corrected Version 67.5.0.1 Abstract

Miscellaneous - SGI Computers With R3000 Chips - Bad Request Code MSC/NASTRAN Version 67.5 does not run on SGI computers with R3000 chips. A message similar to the one below appears in the .log file: Bad request code: /usr2/msc/nast675/nast675/NAST675 Where /usr2/msc/nast675/nast675/NAST675 is the MSC/NASTRAN executable on your machine.

Description

Avoidance: The user must remake the NAST675 executable or request a re-release of MSC/NASTRAN Version 67.5.0.1 on SGI Computers from their MSC sales office. The following C program called "magic" is supplied and must be applied to the MSC/NASTRAN executable. If the user has a C compiler follow the procedure in Note #417.

Known Error

CR 4893

Product

MSC / MD Nastran

Corrected Version 68 Abstract Description

Cyclic Symmetry - PARAM,MPCF - Missing Output A request for forces of multi-point constraints (PARAM,MPCF,YES) in cyclic symmetry (SOL 114) is ignored. Avoidance: A DMAP avoidance for MSC/NASTRAN Version 67.5 is presented

Known Error

CR 4893 below:

ALTERS FOR MPC-FORCES, SOL114 (CYCLIC STATICS), VERSION 675 1. SUBDMAP SEDRCVR NEEDS TO TRANSFORM PGC BACK 2. SUBDMAP SEDRCVR NEEDS TO GET KGG (REASON FOR SUBDMAP CYCMPCF) COMPILE SEDRCVR SOUIN=MSCSOU NOLIST NOREF ALTER 15,19 $ REMOVE MPCF FOR STATICS, V675 IF ( NOMSET>-1 AND MPCF='YES' AND APP='CYC' AND APP1='STATICS' ) CALL CYCMPCF UGVS/QGM1 $ COMPILE CYCMPCF NOLIST NOREF $ SUBDMAP CYCMPCF UG/QGM $ TYPE DB KGG,PGC,BACK,USET $ MPYAD PGC,BACK,/PGB $ MPYAD KGG,UG,PGB/QG///-1 $ UPARTN USET,QG/QGM,,,/'G'/'M'/'N'/1 $ RETURN $ END $ Known Error

CR 4897

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Description

Nonlinear Slide Line Contact - BLSEG - Incorrect Slip Code The "RESULTS FOR SLIDE LINE ELEMENTS" may incorrectly indicate the "SLIP CODE" as "OVERHANG" instead of "OPEN". This condition occurs when the contact surfaces are relatively far apart. The correct slip code is output as the surfaces become closer together. Note that the 2-D Surface Contact capability is considered experimental in MSC/NASTRAN Version 67.5. The capability is not documented in the Version 67.5 Release Notes and can only be accessed through DMAP ALTER. Avoidance: No avoidance is necessary as there is no adverse affect to the converged solution.

Known Error

CR 4898

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Superelements - METHOD, RESTART - Incorrect Eigenvector

Known Error

Description

CR 4898 If the only change in a superelement dynamic restart, is the METHOD selection for the residual structure, the program will correctly calculate the new modes for the residual structure, but if residual structure modes from a previous runs exist on the restart database, they will be used to find the eigenvectors of the upstream superelements. Therefore, it is possible to have incorrect eigenvectors for the upstream superelements. Avoidance: The avoidance is to make a dummy change to the residual structure, for example, adding an additional GRID point.

Known Error

CR 4903

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

Nonlinear Analysis - BEAM, PARAM,LGDISP - Wrong Answers A geometric nonlinear analysis (SOL 64 or SOL 66, 99, 106 and 129 with PARAM,LGDISP) that contains BEAM elements produces poor answers. The answers are not independent of the local BEAM element coordinate system. The magnitude of the error appears to be proportional to the displacement of the structure.

Avoidance: There is no avoidance. Known Error

CR 4907

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Description

Superelements - RESTART, SPC - Wrong Answers If the only change to a superelement restart run is the selected SPC set for the residual structure, incorrect answers result. The correct results are obtained for the residual structure, but the results are unchanged from the previous run for the upstream superelements. Avoidance: Add an SPC entry to the restart bulk data.

Known Error

CR 4914

Product

MSC / MD Nastran

Corrected Version GL Abstract

Optimization/Design Sensitivity - RESTART, DESVAR - Wrong Answers

Description

If an optimization analysis is restarted and the DESVAR entries from the cold start are deleted and replaced, SOL 200 yields wrong answers. Section 7.11 of the MSC/NASTRAN Design Sensitivity and Optmization guide

Known Error

CR 4914 documents this limitation. Avoidance: After the initial cold start is executed, merge the original data deck with the new DESVAR entries from the .PCH file from the initial run and execute the run as a cold start.

Known Error

CR 4915

Product

MSC / MD Nastran

Corrected Version Abstract

Description

Nonlinear Analysis - MATi - Missing Output If a material id contains more than 8 characters, nonlinear stress output is unavailable for any element referencing the material. Material ids containing more than 8 characters are generated by the composite capability and whenever they occur, the program assumes that the material is being used by a composite element. Avoidance: Use material ids with 8 or fewer characters

Known Error

CR 4917

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract Description

Material Nonlinear Analysis - MATS1 - SFM 4276, EC 7777, Numeric Trap If the TABLES1 referred to by a MATS1 for a PLASTIC material does not start at the origin then a numeric trap may occur on IBM RS/6000 systems. Avoidance: Specify the first x-y pair to be 0.0, 0.0

Known Error

CR 4918

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Documentation - DMIG - Inefficient Restarts Automatic restart for superelement analysis may be inefficient if DMIG entries are added or changed. The current logic will process all superelements completely if any DMIG entry is changed from the original run. Avoidance: As long as the DMIG is selected in the CASE CONTROL (i.e., K2GG, M2GG, B2GG), the following alter will remove this part of the logic, while

Known Error

CR 4918 retaining the CASE CONTROL checking logic. COMPILE IFPL, SOUIN=MSCSOU ALTER 90,90 $ V675 This removes the restart checking for BNDFL, DMIAX, DMIG, ELIST, MFLUID, RADLIST, and RADMTX bulk data changes.

Known Error

CR 4923

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Description

Grid Point Stress - GPSTRESS, CHEXA, CTETRA - Missing Routine GPSPTS A request for grid point stress data recovery for a VOLUME containing CHEXA and/or CPENTA elements may fail on the HITACHI VOS3 and FUJITSU MSP/EX MSC/NASTRAN Version 67 systems. The error message issued indicates "MISSING ROUTINE ( GPSPTS ). Avoidance: The error can be avoided by setting the CORDM field on the PSOLID entry to 0 (note that the default for this field is -1).

Known Error

CR 4926

Product

MSC / MD Nastran

Corrected Version GL Abstract

Miscellaneous - - "NaNQ" in the Output

Description

If a term in a matrix becomes too large for the computer to represent, the IEEE standard replaces it with "NaNQ" on the output. Therefore, it is possible to have "NaNQ" appear in the place of numbers in the output from MSC/NASTRAN. If this occurs, it is an indication that the numbers involved are too large to be accurately processed on the computer.

Known Error

CR 4930

Product

MSC / MD Nastran

Corrected Version GL Abstract Description

Sequencer - PARAM,SUPER,2 - Infinite Loop If PARAM,SUPER,2 is specified in the BULK DATA and there are no superelements in the model, the sequencer may enter an infinite cpu loop.

Known Error

CR 4930 Avoidance: Do not use PARAM,SUPER if there are no superelements in the model.

Known Error

CR 4935

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Documentation - TABTST - Insufficient Documentation

Description

The documentation of the TABTST utility program in Section 7 of the MSC/NASTRAN Version 68 Installation and Operation Instructions needs to be enlarged to explain that this is only a sample program that illustrates how to read an output2 file. The sample is for reading a stress datablock. This explanation is contained in the tabtst.f source file. In order for the user to read another datablock, tabtst.f may be used as a guide but the format of the datablock that is to be read must be known. The NDDL (NASTRAN data definition language) file or the Programmer's Manual to determine a specific datablock definition.

Known Error

CR 4937

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Acoustic Analysis - ACRSE - UFM 2071

Description

The Users Manual improperly states that field 4 on the ACRSE entry is used to specify a DPHASE entry. If this field is used to select a DPHASE entry "USER FATAL MESSAGE 2071" is output stating that the load entry specifies an undefined table. Field 5 on the ACSRCE is used to select a DPHASE id, not the DELAY id as indicated in the MSC/NASTRAN Version 67 User's Manual. There is no field that references a DELAY entry on the ACSRCE entry.

Known Error

CR 4938

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Optimization/Design Sensitivity - DEQATN - Poor Message, UWM 229 (PRERR2)

Description

The message "USER WARNING MESSAGE 229 229 (PRERR2)" is output if a semicolon is input at the end of the last equation on a DEQATN entry. The semicolon separates equations on the DEQATN entry but should not be placed after the last equation. Although this is a user input error a better message should

Known Error

CR 4938 be issued to assist the user in locating the input error. Please see error 4525 for a more general description of deficiencies in processing the DEQATN entry.

Known Error

CR 4939

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Optimization/Design Sensitivity - STRAIN(FIBER) - Misleading Answers

Description

A STRAIN(FIBER) case control request is not recognized in quantities related to design optimization. That is, the design responses used in sensitivity and optimization with the DRESP1 entry with RTYPE=STRAIN assume a STRAIN(STRCUR) form. Avoidance: There is no avoidance other than to explicitly provide strain relations on the DEQATN entry.

Known Error

CR 4943

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Documentation - NLPARM, RESTART - Misleading Documentation

Description

The documentation in the MSC/NASTRAN Version 67 User's Manual states that the INTOUT field is used to specify intermediate output requests, (displacements, forces, stress, etc.). There is no specific indication that it controls restartability. Furthermore the Handbook for Nonlinear Analysis specifically states "Further improvements were made in Version 67 so that the data blocks for the last converged load step will be saved if the solution is terminated in the middle of a subcase due to divergence or consumption of the specified CPU time. Consequently, the solution can always be restarted." Contrary to these descriptions the INTOUT field of the NLPARM entry must be set to yes to be able to subsequently restart from the middle of a subcase.

Known Error

CR 4944

Product

MSC / MD Nastran

Corrected Version 68 Abstract

MIgration - DBLOAD, DBTRANU - UFM 6281

Description

Migrating a Version 65C superelement database to Version 67.5 may result

Known Error

CR 4944 in the following fatal message: USER FATAL MESSAGE 6281 (SEP2D) NO SUBCASES ARE SPECIFIED FOR THE RESIDUAL STRUCTURE. IN A STATIC ANALYSIS, AT LEAST ONE SUBCASE MUST BE SPECIFIED FOR THE RESIDUAL STRUCTURE. This error occurs because the CASECC datablock is not stored on the database in Version 65C and Version 67.5 requires the datablock. Avoidance: The following alter circumvents the requirement for the CASECC datablock in Version 67.5: compile dbtranu souin=mscsou noref nolist alter 73,73 SEP2CT SLIST,CASECC,,EMAP,/CASES,,/'reig'/V,N,SEID $ Note that this error has been marked as fixed in Version 68 since migration from Version 65C is no longer supported.

Known Error

CR 4947

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Documentation - DSCREEN - UFM 315

Description

The MSC/NASTRAN User's Manual documentation states, " If TYPE = "LAMA", "EIGN", "WEIGHT" or "VOLUME" then NSTR is not used.". However, if NSTR is input by a user when TYPE is specified as one of the aforementioned responses, the message "USER FATAL MESSAGE 315 (IFPDRV) FORMAT ERROR ON BULK DATA ENTRY DSCREEN" may be issued.

Known Error

CR 4954

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Grid Point Stress - SURFACE, VOLUME - Confusing Message, UWM 4595

Description

An MSC/NASTRAN superelement run in which the residual structure has no elements issues the following at the beginning of data recovery for the residual structure:

Known Error

CR 4954 *** USER WARNING MESSAGE 4595. UNABLE TO OPEN INTERNAL DATA BLOCK (NONE) IN GPSTR1 MODULE - PROCESS STOPPED. if the following Case Control conditions exists: 1) SURFACEs and/or VOLUMEs are defined. 2) No ELSDCON, GPSDCON, GPSTRESS, or STRFIELD Case Control commands are present. Avoidance: Add a dummy element to the residual superelement or disregard the message.

Known Error

CR 4968

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Nonlinear Slide Line Contact - BCONP, BLSEG - Wrong Answers

Description

The DMAP alters delivered for the nonlinear slide line capability in MSC/NASTRAN Version 67.7 produce wrong eigenvalues for nonlinear modes (PARAM,NMLOOP). Note that the nonlinear slide line capability (a.k.a., 2D Contact) is considered experimental in Version 67.5 and 67.7. The capability is only available through DMAP alters.

Known Error

CR 4978

Product

MSC / MD Nastran

Corrected Version Abstract

Elements - CQUAD4 - UFM 4297

Description

If a CQUAD4 element's dimensions are small, in the order of 1.E-5, the job may fail and the message "USER FATAL MESSAGE 4297, ELEMENT HAS AN INTERIOR ANGLE POSSIBLY GREATER THAN OR EQUAL 180 DEGREES" is issued. Avoidance: There is no known avoidance other than to use different units.

Known Error

CR 4981

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Optimization/Design Sensitivity - DRESPi - Meaningless Answers

Known Error Description

CR 4981 If an invalid item code is entered in the seventh field of the DRESP1 entry meaningless results are produced for sensitivity and optimization. Avoidance: Specify a valid plot code.

Known Error

CR 4986

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Description

Documentation - Reference Manual, BEAM - Missing Description of Plastic Hinge For nonlinear analysis, the BEAM element may be used for geometric nonlinearities or for the modeling of a plastic hinge under elastic-perfectly plastic conditions. The latter application by design intent is the only material nonlinearity valid for the BEAM element. Any other type of material nonlinearity, such as creep or a stress-strain curve, will yield inaccurate answers. In the case of creep, due to the assumption that only 1/8 of the length at the ends of each BEAM abides by the nonlinear material law, the BEAM appears too stiff. In the case of a stress-strain curve, the beam acts as a linear element. This is addressed in the Version 68 Reference Manual. Avoidance: ROD elements should be used to model axial material nonlinearities

Known Error

CR 4994

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Documentation - PARAM,FIXEDB - Missing Output, UWM 9012

Description

The current documentation for PARAM,FIXEDB states only that PARAM,FIXEDB,-1 is to be specified in the residual subcase or the bulk data if the modes of the residual structure are not desired. When printout or plots of component modes are desired in SOL 63, PARAM,FIXEDB,-1 must be specified for both the desired superelement(s) and the residual structure. If this is not done, the superelement component fixed boundary modes will not be available and UWM 9012 will be printed.

Known Error

CR 4994 Avoidance: Specify PARAM,FIXEDB,-1 for both the superelement(s) and the residual structure. This can be accomplished by either by specifying the parameter in the BULK DATA or by specifying the parameter in CASE CONTROL for both the superelement(s) and the residual structure.

Known Error

CR 5003

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Documentation - Superelements, STRESS(CORNER) - Missing Output

Description

The Release Notes for MSC/NASTRAN Version 67.5 state that the request for CORNER output must occur in the first SUBCASE. This is correct for conventional analysis. In superelement analysis this input yields standard center stress output for the upstream superelement only. If the run is using superelements, the request must be above the SUBCASE level or in the first residual structure SUBCASE.

Known Error

CR 5011

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Security - Incorrect Authorization Codes - SFM 3060 There are bugs in the SUN4 version of the MSC/NASTRAN authorization code generator that create bad authorization codes. It sometimes creates authorization codes that will not allow MSC/NASTRAN to run, while other times particular solution sequences will not work. The following is a list of reported problems:

Description

-For VAX/VMS, we cannot get a code (3 times) -For HP9000, we cannot get it sometimes,not always. -For SUN4, we cannot get it for Nonlinear option. -For CONVEX, grid point limitation inadvertently set.

Avoidance: When an incorrect authorization code is found by the client, send the necessary information to LA and we will generate the code for you since the VAX

Known Error

CR 5011 authorization code generator always gives a correct code.

Known Error

CR 5017

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract Description

Cyclic Symmetry - SOL 115 - Missing Plots In SOL 115 (CYCLIC Modes), if repeated roots exist for a harmonic, the batch plotter will not create stress plots for the second occurence of the eigenvalue.

Known Error

CR 5018

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Description

Matrix Methods - SMPYAD - SFM 4276, EC 7777, Segmentation Fault A multiplication of the type [A]T[B][A]+[C] results in an error in the SMPYAD module if the precision of the output matrix is set different than the machine precision. This error does not occur in any unaltered delivered solution sequence. Avoidance: Either do not set the precision of the output matrix or replace SMPYAD with the equivalent calls to MPYAD.

Known Error

CR 5020

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Optimization/Design Sensitivity - DEQATN - Wrong Answers A DEQATN of the form F(A,B) = F**2 + B**2 should fail to compile because the right hand side of the equation refers to the function defined on the left hand side, but it does not.

Description Avoidance: Do not define DEQATNs where the right hand side of the equation refers to the function on the left hand side. Known Error

CR 5021

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Acoustic Analysis - MODEPT, PACABS - SFM 4276, EC 7777

Known Error

Description

CR 5021 If a PACABS entry references a non-existant table or the table contains negative frequency values, then UFM 6167 should be issued and the run should terminate in the MODEPT module. In some instances the UFM 6167 is missing, the run fail in the MODEPT module but issues the message "SYSTEM FATAL MESSAGE 4276 ERROR CODE 7777" instead. Avoidance: Correct the PACABS entry or supply the missing tables.

Known Error

CR 5024

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Composites - PCOMP - Extraneous Output The header: "F A I L U R E I N D I C E S F O R L A Y E R E D C O M P O S I T E E L E M E N T S" is output to the f06 file even when no failure calculation is requested (i.e., the FT field on the PCOMP entry is left blank). Avoidance: There is no avoidance.

Known Error

CR 5031

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Superelements - DBLOCATE - Wrong Answers for SE SPC changes

Description

SYSTEM(143)=1 specifies that the bulk data is being obtained via the DBLOCATE FMS statement. Although it is not documented, the design intent is to allow load changes only when SYSTEM(143)=1 is specified. Any other changes such as connectivity, grid location or constraints are reflected in the bulk data echo but are not effective even when they apply to superelements that have yet to be processed.

Known Error

CR 5034

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Optimization/Design Sensitivity - DRESP1, BEAM, BAR, BEND - Meaningless Answers

Description

The BEAM, BAR, ROD and BEND elements set the margin of safety to an integer value of 1 when the stress in the element is zero. Further, for the BAR, BEAM and BEND elements which have separate tension and compression

Known Error

CR 5034 margins, if the element is purely in tension, the compression safety is set to 1. The module which calculates DRESP1 values does not know about this convention and therefore uses the real number equivalent to 1 in its computation. On many machines the real number equivalent to the integer 1 is a real number near zero. Thus, if the analysis has been defined to achieve larger margins meaningless answers may result. There is a similar problem in modal response calculations when the DDRMM parameter is 0. In this case the margin of safety cannot be calculated but the DRESP1 ev

Known Error

CR 5035

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

Dynamic Analysis - DDRMM, CBEAM, CBAR, CBEND - Incorrect Margins of Safety The margins of safety cannot be calculated correctly in a modal dynamic response analysis when PARAM,DDRMM is 0. Depending on the element and Version of MSC/NASTRAN the printed value of the margin of safety may be incorrect or simply 0.0. Avoidance: If the margin of safety output is desired for dynamic analysis the user must select PARAM,DDRMM,-1.

Known Error

CR 5041

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Description

Acoustic Analysis - ACMG - SFM 6211, Poor Message The message "SYSTEM FATAL MESSAGE 6211 (ACMG), A NORMAL TABLE HAS BEEN INCORRECTLY CREATED" is misleading. The message is the result of a problem in the boundary area factor generation code in the ACMG module. The error is believed to be caused by a problem with LOCATE. The message occurs when a CHEXA fluid element in the ECT table can not be located. Avoidance: The only avoidance is to specify the "IDENT" option on ACMODL entry. Since the "IDENT" option requires a matching interface between the structure and fluid in most cases the model must be remeshed.

Known Error

CR 5044

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Eigenvalue Analysis - SDR2 - Incorrect Element Force Label

Description

An incorrect eigenvalue label is output for element forces when the generalized mass of an eigenvalue is zero. Avoidance: There is no avoidance.

Known Error

CR 5047

Product

MSC / MD Nastran

Corrected Version GL Abstract

Installation - IBM 386/486 IX - UFM 3060 When both the mouse and the authorization device (dongle) use the same port (for example the com1 serial port) MSC/NASTRAN will not run and UFM 3060 is received.

Description Avoidance: The only avoidance is to obtain another serial port and use one for the mouse and one for the authorization device.

Known Error

CR 5050

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Postprocessing - PARAM,POST,-1 - Missing Data When using SOL 105 with PARAM, POST, -1, the datablocks from the static subcase, the differential stiffness results, are missing from the OUTPUT2 file. Only the geometry and buckling modes are contained in the OUTPUT2 file. Avoidance: To obtain the results from both subcases, insert the following alters:

Description

For Version 67.5: SOL 105 $ V67.5, PATVER=3.0 COMPILE DMAP=SEBUCKL,SOUIN=MSCSOU,NOLIST,NOREF ALTER 29 $ BEFORE SUPER3, STATICS TYPE PARM,,I,Y,OTAPE2 $ OTAPE2=-1 ALTER 55 $ AFTER SUPER3, BUCKLING TYPE PARM,,I,Y,OUNIT2 $ $ WRITE END-OF-DATA ON FORTRAN UNIT OUNIT2

Known Error

CR 5050 OUNIT2=12 OUTPUT2 //-9/OUNIT2 $ COMPILE DMAP=SUPER3,SOUIN=MSCSOU,NOLIST,NOREF ALTER 170 $ BEFORE OUT2GEOM IF (APP1='BKL1 ') OTAPE2=0 ALTER 181,181 $ REMOVE EOF ON OUTPUT2 FILE ENDDALTER

SOL 105 $ V67 Known Error

CR 5056

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Elements - QUAD4(CORNER) - Poor Answers The STRESS(CORNER) request may produce a large variation in the answers for QUAD4 corner stresses for elements with thickness variation or warp.

Description

Avoidance : It is recommended that STRESS(BILIN) be used for problems with warp or thickness variation. The default option for STRESS(CORNER) is changed in Version 68.2 to BILIN to address this problem. See also error 6421.

Known Error

CR 5058

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Cyclic Symmetry - Normal Modes, READ or REIGL - UWM 8592, SWM 3001 A cyclic symmetry modal analysis that fails to specify NOUTPUT (the segments for which output is desired) or HOUTPUT will fail issue the following messages:

Description

*** USER WARNING MESSAGE 8592, (REIG). THE METHOD RECORD IN CASE CONTROL IS MISSING OR INCORRECT. THIS WILL CAUSE THE FOLLOWING FATAL ERRORS. USER ACTION: PUT A METHOD ENTRY IN CASE CONTROL WHICH POINTS TO AN EIGR, EIGRL, OR EIGB RECORD IN BULK DATA. 0*** SYSTEM WARNING MESSAGE 3001 MODULE = READ 0ATTEMPT TO OPEN DATA SET 105 IN SUBROUTINE REIG , WHICH WAS NOT DEFINED

Known Error

CR 5058 IN THE FIST Avoidance: Specify NOUTPUT or HOUTPUT in the Case Control.

Known Error

CR 5062

Product

MSC / MD Nastran

Corrected Version 69 Abstract

File Management Section - INIT - UFM 426 (RDINIT) ILLEGAL KEYWORDS The word "LOGICAL" or "SCR300" must not appear starting in column one (1) on the INIT statement if there is more than one (1) member being defined, else "USER FATAL MESSAGE 426 (RDINIT) THE FOLLOWING KEYWORDS ARE ILLEGAL FOR THE INIT COMMAND" is output. Avoidance: The following are examples of valid and invalid INIT entries:

Description

$ -Invalid FMS- $ -Valid FMS- $ -Valid FMSINIT MASTER(S) INIT MASTER(S) INIT MASTER(S) INIT SCRATCH, INIT SCRATCH, INIT SCRATCH, LOGICAL=(SCR1,SCR2), LOGICAL=(SCR1,SCR2), LOGICAL=(SCR1), SCR300=(SCR3,SCR4) SCR300=(SCR3,SCR4) SCR300=(SCR2) INIT DBALL, INIT DBALL, INIT DBALL, LOGICAL=(DB1,DB2) LOGICAL=(DB1,DB2) LOGICAL=(DB1) ENDJOB ENDJOB ENDJOB

Known Error

CR 5063

Product

MSC / MD Nastran

Corrected Version 67.5 Abstract

DBLOCATE COPY Fails - SFM 1013

Description Known Error

CR 5090

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Documentation/QRG - PACABS, TABLED2, TABLED3, TABLED4 - UFM 6167

Description

If the table that is used to define the resistance, reactance, or weighting function is the type TABLED2, TABLED3, or TABLED4, then the program issues "USER FATAL MESSAGE 6167 THE BULK DATA TABLED1 ENTRIES, ID= N WERE NOT SUPPLIED"

Known Error

CR 5090 Avoidance: The PACABS entry should reference TABLED1 entry instead. - note this is a documentation error. Tables referenced by TID1, TID2, TID3 can only be TABLED1- The TABLEDi i=2,3,4 imply a certian look up strategy TABLED2 and TABLED3 by shifting the curve and compressing the x-axes. TABLED4 is a polynomial expansion. The PACABS entry does not use these tables for look up. Rather it uses TABLED1 to perform a least square fit to determine a K and M value which bests fits the curve.

Known Error

CR 5091

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Acoustic Analysis - ACMG - Poor Performance

Description

Acoustic element problems with coupled fluid/structure boundaries and non"IDENT"ical meshes can lead to excessive cpu time. Avoidance: Other than using identical meshes, there is no avoidance.

Known Error

CR 5101

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Description

Superelements - SEMA, CSUPER, Multi-Master Method - UFM 4252 When using the multi-master method with image superelements on Version 67.7, "USER FATAL MESSAGE 4252, DATA BLOCK NOT FOUND IN DATABASE" may be issued by the SEMA module for the image superelement. Avoidance: The problem is under investigation. The only avoidance is to use the conventional (single-master) approach.

Known Error

CR 5102

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Aeroelastic Analysis - AEFACT - Wrong Answers

Description

Changes in the AEFACT bulk data entry should, on restart, force the recomputation of the aerodynamic matrices. However, the required dependencies are absent in the NDDL with

Known Error

CR 5102 the result that the aerodynamics are not recalculated and the user's intent is not fulfilled. Avoidance: Submit the job as a cold start.

Known Error

CR 5106

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Miscellaneous - BFORCEA.V675 - Wrong Answers When using the bforcea.v675 alter in the sssalter directory, if different load ids are specified for different superelements in the Case Control, incorrect answers may result. This is due to the LOAD qualifier's value remaining at the last value used, even though different values are necessary for each superelement during data recovery. Standard data recovery is not affected by this. Avoidance: Modify the alter by replacing the line

Description

MPYAD KAA,ULS,PL/BFORCEL///-1 $ CALC BOUNDARY FORCES with the following: TYPE PARM,,I,N,SEID1 $ SEID1 = SEID $ DBVIEW MYPL=PL, (WHERE SEID=SEID1 AND WILDCARD = TRUE) $ $ CORRECT THE MPYAD TO HAVE MYPL, INSTEAD OF PL MPYAD KAA,ULS,MYPL/BFORCEL///-1 $ CALC BOUNDARY FORCES

Known Error

CR 5110

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Nonlinear Superelement Analysis - PARAM, BUCKLE,1 - Missing Output

Description

Solution 106 with buckling (PARAM,BUCKLE,1) is not designed for upstream data recovery. A request for upstream data recovery is ignored.

Known Error

CR 5124

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Restarts - DBSTORE - DBSTORE Not Executed

Description

The restart logic in the SSS will prevent the execution of the DBSTORE subdmap during restart runs.

Known Error

CR 5124 Avoidance: To force execution on restart set system cell 109 to 1 before the call to DBSTORE. This action turns off restart checking. That is: putsys(1,109) $ turn restart checking off CALL DBSTORE A,B,,,//QUAL1/QUAL2/DBSET/COND $ putsys(0,109) $ turn restart checking back on This error is considered to be a documentation error and has been fixed in Version 68 by adding an appropriate remark under the description of the DBSTORE module in the DMAP Module Dictionary.

Known Error

CR 5137

Product

MSC / MD Nastran

Corrected Version 68 Abstract

DBC/TRANS/ACCESS - ACCESS, Application Manual - Incorrect Documentation

Description

All references to "MSC07" in Section 7.7.6 of the MSC/NASTRAN Version 67.5 IBM MVS/XA Application Manual should be changed to "MSC06A". These changes must be made to install the program.

Known Error

CR 5146

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Restarts - SPCD - Wrong Answers

Description

If all SPCD entries are entered on the initial run, and a different set is selected on a restart run, the program will use the set called out in the initial run, resulting in incorrect answers. Avoidance: Add or change an SPCD entry on the restart run.

Known Error

CR 5160

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Elements - CHEXA, CPENTA - UFM 4658

Description

"USER FATAL MESSAGE 4658, DIFFICULT GEOMETRY PREVENTS FURTHER

Known Error

CR 5160 COMPUTATIONS FOR ELEMENT WITH ID = ***" is presently encountered when solid elements have an aspect ratio greater than 1000. This geometry check is changed in MSC/NASTRAN Version 68 such that the fatal message is only encountered if elements have bad aspect ratios in two directions. That is only elements that are long and thin like a straw should encounter this fatal message.

Known Error

CR 5164

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Restarts - PARAM,SERST,SEMI - ? PARAM,SERST,SEMI may skip PHASE1 on a restart run, even though the SUPER command requests processing for the superelement. The restart logic properly deletes datablocks, however, the requested processing may not be performed.

Description

Avoidance: The following DMAP alter forces execution of PHASE1 compile super1 souin=mscsou nolist noref alter 35 putsys (1,109) alter 36 putsys (0,109)

Known Error

CR 5178

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Nonlinear Buckling Analysis - SPCD - SFM 6036, Wrong Answers Nonlinear buckling in SOL 106 does not work if the loading includes enforced displacements. If the load consists entirely of enforced displacements, the following message will occur:

Description

SYSTEM FATAL MESSAGE 6036 (XQAROS) ATTEMPT TO DIVIDE BY REAL, SINGLE PRECISION ZERO USER INFORMATION: 1. PROCESSING ASSIGNMENT STATEMENT: ALPHA AT DMAP SEQUENCE NUMBER: 360 PROGRAMMER INFORMATION: 1. PROCESSING INSTRUCTION: / 00000005 00010005 00000002

Known Error

CR 5178 If enforced displacements are combined with other load types, then the critical load factor ALPHA will be computed incorrectly. This error can be avoided using the following DMAP alter: compile nlstatic $ alter for sol 106 in V70.5 to correct an error in CSR 5178 $ nonlinear buckling analysis made possible

Known Error

CR 5209

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Description

Documentation - STRESS(VONMISES), PCOMP - Max Shear Stress is Always Output For composite shell elements, the default for the ply stress output is Max Shear. In fact this calculation is hard-coded into MSC/NASTRAN, requesting von Mises is ignored. The 2nd printing the Version 68 Quick Reference Guide has been updated to correct this error. Avoidance: This is a limitation of the code. The documentation for STRESS command should be updated to reflect this limitation.

Known Error

CR 5212

Product

MSC / MD Nastran

Corrected Version 70 Abstract

Miscellaneous - STRESS(CORNER), SUBCOM - Missing Output The corner stress data recovery is not done in SUBCOM if the corner stress output request does not exist in the first SUBCASE. The following is an example which will produce missing output:

Description

SUBCASE 1 LOAD = 1 SPC = 1 SUBCASE 2 LOAD = 2 SPC = 1 SUBCOM 3 STRESS(CORNER) = ALL SUBSEQ = 1.0,1.5 Avoidance: The following input avoids the error:

Known Error

CR 5212 STRESS(CORNER) = ALL SUBCASE 1 STRESS(CORNER) = NONE LOAD = 1 SPC = 1 SUBCASE 2 LOAD = 2 SPC = 1 SUBCOM 3 SUBSEQ = 1.0,1.5

Known Error

CR 5227

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Documentation - PARAM,PANELMP, -1 - Missing Modal Participation Factors

Description

The description of the FLUIDMP and PANELMP parameters in the Quick Reference Guide states that "If n=-1 for any parameter, then (modal participation) factors will be output for all modes". In fact if PARAM,PANELMP is set to -1 no modal participation factors are output. Avoidance: Set PARAM,PANELMP to the number of modes that modal participation factor output is desired.

Known Error

CR 5229

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Description

Heat Transfer Analysis - SOL 101, APP HEAT,TRIA3, MAT5 - Wrong Answers Heat transfer flux data recovery for TRIA3, TRIA6, and QUAD8 elements which reference MAT5 (anisotropic) material properties is incorrect. When using MAT5 (anisotropic) materials, the user supplied matrix must be transformed to the element system. The values needed for this transformation are not calculated. Whatever values are currently stored in memory is used for the transformation matrix, yielding unpredictable results. If only TRIA3 elements are used, and the memory is initialized to zero (as it is on the VAX/VMS), the FLUX output will be zero. Avoidance: There is no avoidance.

Known Error

CR 5232

Product

MSC / MD Nastran

Known Error

CR 5232

Corrected Version 68 Abstract

Acoustic Analysis - RMS Velocity - Wrong Answer

Description

The (RMS of the velocity)=(RMS of the Acceleration/2*PI*f). In MSC/NASTRAN Version 67 and 67.5 the (RMS of the velocity)= (RMS of the Acceleration/f) for fluid degrees of freedom. Thus, the RMS velocity for fluid degrees of freedom output by MSC/NASTRAN is off by a factor of 2*PI.

Known Error

CR 5255

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

Dynamic Response Analysis - Superelements - Missing Output When performing frequency response using superelements, no output will be available for any superelement which is not mentioned in a SUBCASE for dynamic loading. This design extends to XYPLOT output. This is especially pronounced when multiple residual solutions are requested using multiple subcases. Avoidance: For each residual subcase, a corresponding subcase for each superelement should exist in the input.

Known Error

CR 5267

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Documentation - Acoustic Analysis, DYNRED, GDR - Missing Output

Description

If a modal approach is used for fluid-structure interaction, Generalized Dynamic Reduction should not be used. If used, the generalized dynamic reduction is performed on the combined matrices and the program will use those matrices in the structural eigenvalue problem. This will provide both the structural and fluid modes, but the program requires the fluid and structural modes to be separate in order to calculate the coupling terms.

Known Error

CR 5277

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Optimization/Design Sensitivity - Buckling, DSAL - SFM 4276, EC 1409

Description

If more than one buckling subcase exists in a SOL 200 run, the program will terminate with SFM 4276, ec 1409 in DSAL. This limitation has been removed

Known Error

CR 5277 in Version 69. Avoidance: If buckling optimization is used, use only one buckling SUBCASE.

Known Error

CR 5282

Product

MSC / MD Nastran

Corrected Version Abstract

Documentation - Reference Manual, CRAC2D, CRAC3D - Incorrect Documentation

Description

Table 1 in Section 5.1 of the Version 68 MSC/NASTRAN Reference Manual indicates that temperature loads are not supported for the CRAC2D and CRAC3D elements. In fact temperature loads are supported for these elements.

Known Error

CR 5292

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Aeroelastic Analysis - CAERO3, CAERO4, CAERO5, ADG - Datablock 107 is Missing

Description

In Version 67.7, the static aeroelastic capability includes a divergence analysis that can be based on an aerodynamic model using any of the available aero methods. However, trim and stability analysis does not allow Strip, Mach Box or Piston theories. If the user attempts the latter, a SYSTEM FATAL MESSAGE indicating missing datablock 107 is output by the ADG module. Earlier Versions of MSC/NASTRAN provide an explicit message that the user requested capability is not supported.

Known Error

CR 5294

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Dynamic Response Analysis - Modal Transient Analysis - Poor Answers

Description

If a modal transient analysis is performed with eigenvalues which vary by several orders of magnitude (the problem which demonstrated this had eigenvalues ranging from 10e1 to 10e10), then poor answers may result. The degradation of the answers is a result of using the single-precision LAMA table to generate the modal matrices which are used for the integration. The problem is not as pronounced on long word (i.e. CRAY) computers.

Known Error

CR 5294 Avoidance: In these cases, a direct transient solution using either superelements, or GDR would be more accurate.

Known Error

CR 5300

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Composites - PCOMP, MAT8, IFP - UFM 315. If either Xt or Xc or Yt or Yc or S are specified on the MAT8 entry, then Xt and Yt and S must also be specified even though the FT field on the PCOMP entry is blank indicating that no failure calculation is to be performed. If some but not all of the allowable mentioned are not specified, then the run fails and the message " USER FATAL MESSAGE 315 (IFPDRV) FORMAT ERROR ON BULK DATA ENTRY MAT8" is encountered. Avoidance: Always enter at least XT, YT, and S allowable terms or none at all of XT, XC, YT, YC, and S on the MAT8 entry.

Known Error

CR 5303

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Superelements - MPYAD - UFM 5423, Attempt to Multiply Incompatible Matrices When superelements are used in a static solution and there are more subcases for a superelement than there are for the residual structure and the load sequence number is not specified on the SUPER command in the superelement subcases, the program will terminate with UFM 5423 ATTEMPT TO MULTIPLY INCOMPATIBLE MATRICES in module SDR1. Avoidance: Ensure that the number of subcases for a superelement does not exceed the number of residual structure subcases or specify the load sequence number on all SUPER commands.

Known Error

CR 5304

Product

MSC / MD Nastran

Corrected Version 70.5

Known Error

CR 5304

Abstract

Case Control - SET - No Warning Message

Description

The documentation states that a SET may be redefined in the case control. This is true, however, the second definition is ignored and the first one is used. No warning message is issued and this is inconsistent with the design of other Case Control commands that are defined twice.

Known Error

CR 5325

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Transient Analysis - TRD1 - SFM 4276, EC 7777

Description

A floating point overflow can occur when the uncoupled integration algorithm is used in module TRD1. It is believed that this occurs when unrealistic parameters are chosen. The modal mass, damping and stiffness for the problem that failed were Mi = 1. , Bi = 2.5+5 , and Ki = 6.9389-18 . Avoidance: The error can be avoided by setting PARAM NONCUP = 1 , which forces the coupled integration algorithm. Another avoidance is to add a very small spring to a DOF active in this mode so that its eigenvalue is larger. Ki is proortional to the eigenvalue.

Known Error

CR 5331

Product

MSC / MD Nastran

Corrected Version Abstract

Description

Material Nonlinear Analysis - TEMP(LOAD) - wrong answers Using Solution 106 with HEXA, PENTA or TETRA elements having midside nodes and temperature loads gets wrong answers because the material properties are not updated properly. The error occurs because TEMP(LOAD) is used to determine the temperature dependent material properties for module SSG1, which generates the loads, but the temperature dependent material properties are ignored for module SDR2, which provides data recovery. Avoidance: There are two possible avoidances for V67 1. This avoidance uses the SOL 101 method in module SSG1 and requires that no nonlinear elements except GAPS exist in the deck. COMPILE NLSTATIC SOUIN=MSCSOU NOLIST NOREF ALTER 177,177 $ REPLACE SSG1, VERSION 67 MESSAGE //'SUBDMAP NLSTATIC, MODULE SSG1, APPROACH=ALL ' $

Known Error

CR 5331 SSG1 SLT,BGPDTS,CSTMS,SILS,EST

Known Error

CR 5335

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

Aeroelastic Analysis - FA1 - Wrong Output Starting in Version 67.5 of MSC/NASTRAN the "less critical" real flutter roots are printed for informational purposes. However, this printout is incorrect when these roots are "almost" real roots. Avoidance: Turn DIAG 39 on to request printout of all the roots in order to get a complete picture from this printout.

Known Error

CR 5336

Product

MSC / MD Nastran

Corrected Version 70 Abstract

Postprocessing - DBC - SWM 6065, UWM 3030,Missing Output The DBC module in MSC/NASTRAN which creates the xdb file may issue the following warning messages: 0*** SYSTEM WARNING MESSAGE 6065 (DBC) *** DBCMSG ERROR MESSAGE 23 FROM SUBROUTINE GRIDBK OUTPUT LIST SYNCHRONIZATION PROBLEM FOR aaaa VALUE = xxxxx, POSITION = n or:

Description

0*** SYSTEM WARNING MESSAGE 6065 (DBC) *** DBCMSG ERROR MESSAGE 23 FROM SUBROUTINE ELMBLK OUTPUT LIST SYNCHRONIZATION PROBLEM FOR aaaa VALUE = xxxxx, POSITION = n where: aaaa is the datablock that is having problems, xxxxx is the problem value n is the problem position. These messages are indication that a mis-match of data is being passed to the DBC module. All conditions that can trigger the error are not yet fully understood but the error appears to be

Known Error

CR 5339

Product

MSC / MD Nastran

Corrected Version 69

Known Error

CR 5339

Abstract

Documentation - Coordinate System for Components of Scalar Elements

Description

The MSC/NASTRAN Quick Reference Guide description of scalar elements should be clarified to state that the component number for all scalar element connection entries (CELASi, CDAMPi, CMASSi) refer to the grid displacement coordinate system, i.e., (CD) on the GRID entry.

Known Error

CR 5341

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Plotting - XYPLOT, XYTRAN - UWM 979, Punch Output Constains Control Charachters

Description

The XYTRAN module may encounter a traceback, output control charachters and/or incorrectly issue USER WARNING MESSAGE 979 indicating that elements do not exist.

Known Error

CR 5349

Product

MSC / MD Nastran

Corrected Version Abstract

Miscellaneous - OUTPUT2 - Output Written to Log File

Description

If a user-written DMAP alter uses OUTPUT2 without specifying the output unit, then the default value of 0 is used for the output unit. On some systems, unit 0 is a valid unit and a file will be created. On other systems, it may not be a valid unit and the results may be unpredictable. On the IBM RS/6000 and the SGI, it will write the information to the log file.

Known Error

CR 5350

Product

MSC / MD Nastran

Corrected Version GL Abstract

MSGMESH, MSGSTRSS, MSGVIEW - MSGMESH, IFP - UFM 2052

Description

If free format is used in conjunction with MSG/MESH, and the individual field exceeds 8 characters, then the extra characters may be treated as the next field in MESH command which can lead to unexpected results. If this extra data is invalid for MSG/MESH, then the job may fail UFM 2052 or other fatal messages depending on the type of error. SPC,101,60817,1,0.0066767 when used in conjunction with MESH will generate the following error

Known Error

CR 5350 message: 0*** USER FATAL MESSAGE 2052, UNDEFINED GRID POINT 7 IN SINGLEPOINT CONSTRAINT SET 101 Avoidance: When using MESH and free format, keep within the 8 field format.

Known Error

CR 5353

Product

MSC / MD Nastran

Corrected Version 70.5.1 Abstract

Description

Plotting - PLOT - SFM 4276 EC 3002, FREAD If structure plots are requested for CTRIAX6 elements, then the job will fail and the message "SYSTEM FATAL MESSAGE 4276 ERROR CODE 3002 FREAD ERROR" is issued. Avoidance: There is no avoidance.

Known Error

CR 5369

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Grid Point Force - GPFDR, CGAP, CELAS2, TEMP(LOAD) - SFM 6223 If grid point force balance output (GPFORCE) is requested for CGAP and/or CELAS2 elements, and there is thermal loads, then the job fails in the GPFDR module and the following message is issued:

Description

SYSTEM FATAL 6223 (GPFDR2), RECORD POINTED AT BY INDEX IN SCRATCH FILE IS WRONG. USER ACTION: CONTACT MSC CLIENT SUPPORT Avoidance: Other than not requesting this output, there is no avoidance.

Known Error

CR 5373

Product

MSC / MD Nastran

Corrected Version 2001 Abstract Description

Postprocessing - OUTPUT2 - Neutral option fails when writing OES1X in SOL 106 The OUTPUT2 neutral option fails when writing the OES1X datablock in SOL 106.

Known Error

CR 5373 Avoidance: Use the binary option.

Known Error

CR 5393

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Optimization/Design Sensitivity - DEQATN - Wrong Answers The EQID field on the DEQATN entry must be unique. However, no uniqueness test is performed. Therefore, if the EQID is not unique, incorrect answers may result or the run may issue a message stating that a "wrong number of arguments" is provided on the DEQATN entry. Avoidance: Do not give more than one EQID the same value.

Known Error

CR 5394

Product

MSC / MD Nastran

Corrected Version Abstract

Description

Optimization/Sensitivity - CORDiC,CORDiS - Inaccurate Results When displacements are defined in a non-rectangular global coordinate system, their sensitivity results are inaccurate. In turn, the associated stress sensitivities are also affected. Avoidance: Use a rectangular global coordinate system.

Known Error

CR 5400

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Composites - PCOMP, TEMP(INIT) - Wrong Answers The TEMP(INIT) case control command supersedes the TREF field in the bulk data section in the event that both values exist. However, for composite plate elements that are referenced by a PCOMP entry, the TEMP(INIT) is ignored which can lead to wrong answers. Avoidance: If a PCOMP exists in the model, use the TREF field on the PCOMP entry instead of the TEMP(INIT) case control command.

Known Error

CR 5401

Product

MSC / MD Nastran

Corrected Version 68.1

Known Error

CR 5401

Abstract

Miscellaneous - TABPRT - NDDL Description of DATABLK CMLAMA is Incorrect The NDDL description of DATABLK CMLAMA is incorrect for both the unstructured and structured solution sequences. Print labels will be wrong if the formatted option (P3>0) is selected on the TABPRT module. The formatted option of the OUTPUT2 module and migration is not affected by this.

Description Avoidance: In the cnddls.dat file in the del directory replace the existing DATABLK CMLAMA statement and all subsequent statements up to but not including the next DATABLK statement with the following: øDATABLK CMLAMA TYPE=TABLE PATH=MLAA1 LOCATION=DBUPX, SAMEAS,LAMA,EOF Known Error

CR 5402

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Heat Transfer - VIEW3D, PARAM,VIEW3D,1 - SFE 4276, EC 7777 On the HP 9000 Version 67 and later releases of MSC/NASTRAN, if the Gaussian integration method (PARAM,VIEW3D,1) is used to compute the geometric view factors, then the job may fail with the following message: SFE 4276 - EC 7777 - RECEIVED SIGNAL 10 - ABORTING

Description Avoidance: Use one of the following avoidances to compute the geometric view factors: 1. Add a dummy HBDY element. 2. Use the finite difference or contour integration method instead of the Gaussian integration. Known Error

CR 5409

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Transient Response - OTIME - Wrong Labels

Description

If the OTIME case control command is used on a model with superelements in SOL 109, the correct output values are calculated, but they are labeled

Known Error

CR 5409 with incorrect time values for superelements outside the residual structure. Although the output is given for the correct time steps as specified on the OTIME command, the time labels appear in sequential order starting with the initial time, as they would without the OTIME request. Avoidance: Place all superelements in the residual structure or remove the OTIME request.

Known Error

CR 5410

Product

MSC / MD Nastran

Corrected Version 70 Abstract

Nonlinear Analysis - MATS1, NLITER - SFM 4276, EC7777

Description

On the VAX, if the elastic-perfectly plastic option is used for the work hardening slope by letting H=0.0 (the default) on the MATS1 entry, then the job may fail in the NLITER module and issue the message "SYSTEM FATAL MESSAGE 4276 - ERROR CODE 7777". Avoidance: Specify a small number for the work hardening slope (e.g., 1.E10).

Known Error

CR 5414

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Description

Complex Eigenvalue Analysis - EIGC, CLAN - Wrong Answers In some cases, erroneous right eigenvectors have been produced by the Lanczos method of complex eigenvalue extraction. An unsymmetric mass matrix may be the cause of the error. In one known case results were found to be incorrect on the IBM RS/6000 system but correct on the DEC VAX/VMS release. Version 70.5 of MSC/NASTRAN introduces Block Complex Lanczos eigenvalue extraction method which will solve this problem. The new method is not yet the default and must be selected by setting system(108)=4. Avoidance: There is no avoidance. However, it is recommended that, if complex eigenvectors are an integral part of an analysis, the results be checked using the DMAP alter contained in Section 7.5 of the MSC/NASTRAN User's Guide for Numerical Methods,

Known Error

CR 5414 Version 67 edition.

Known Error

CR 5416

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Superelements - SEDRCVR - Extra Output for Upstream Superelements If a solution 106 analysis contains superelements, and output (e.g., displacement) is requested for the residual structure, then an error in the DMAP results in the same type of output being printed for the upstream superelements even though no output is requested for these superelements. Avoidance: Insert the following DMAP avoidances:

Description

$ $ for v67 and v67.5 $ compile sedrcvr souin=mscsou nolist noref $ alter 199,199 $ if (seid=0) then $ OFP OUGV1,OPG1,OQG1,OEF1X,OSTR1//S,N,CARDNO $ endif $ $ $ for v68 $ compile sedrcvr souin=mscsou nolist noref $ alter 209,209 $ if (seid=0) then $ OFP OUGV1,OPG1,OQG1,OEF1X,OSTR1,, CSTMS,EPTS,GEOM1VU,ERROR1// S,N,CARDNO//PVALID $ endif $ $

Known Error

CR 5418

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

File Management Section - INIT - Unpredictable results

Description

If more than one INIT statement is supplied per LOGICAL DBset, then unpredictable results occur. For example: INIT DBALL LOGICAL=(DB01(100),DB02(100),DB03(100),DB04(100))

Known Error

CR 5418 INIT DBALL LOGICAL=(DB05(100),DB06(100)) creates DB05, DB06, DB03, and DB04 members of DBALL but DBO1 and DB02 are not created. No warning or fatal messages is issued. Avoidance: Specify only one INIT statement per LOGICAL DBset. A continuation of the INIT statement may be specified by ending a line with a comma as follows: INIT DBALL LOGICAL=(DB01(100),DB02(100),DB03(100),DB04(100) , DB05(100),DB06(100))

Known Error

CR 5422

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Optimization/Sensitivity - DSCM2 - Wrong Sensitivities, UFM 5165 MSC/NASTRAN Version 67.7 and 68 do not calculate sensitivities due to damping effects for modal transient response. Therefore, either the sensitivity results are not accurate or the message "USER FATAL MESSAGE 5165 (DSVG1D-1) UNDEFINED INPUT FILE = 106, NAME = (NONE) , ERROR CODE = -6, MODULE DSVG1 IS TERMINATED" is output.

Description Avoidance: Use the following DMAP avoidance for version 68 only. compile pslgdv list noref souin=mscsou $ alter 199 $ IF ( DODFREQ>0 OR DOMFREQ>0 OR DOMTRAN>0 ) EMG, EST,CSTMS,MPTS,DIT,,,,,,/ ,,,,BELM,BDICT/0/0/S,N,NOBGG $

Known Error

CR 5423

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Optimization/Design Sensitivity - DRESP1, DRESP2 - Extra Column in DSCM2 Matrix

Description

If a DRESP2 entry does not reference a DRESP1 entry and if there are multiple solution types (there are three: frequency response, modal transient, and everything else), the DRESP2 entry is included in each solution type. For this to be a problem, the DRESP2 entry must be invoked by a DESOBJ

Known Error

CR 5423 request. The error is benign in that the problem can only have one objective but it does manifest itself as a duplicate column in the DSCM2 matrix.

Known Error

CR 5425

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Documentation - AUTOSPCR - UFM 6137, UFM 5225, UWM 3057, SFM 3002

Description

When performing nonlinear analysis, PARAM,AUTOSPC does not operate on the residual structure, PARAM,AUTOSPCR is provided for that function. However, PARAM,AUTOSPCR does not behave in the same way as AUTOSPC. It only operates on the o-set. Therefore, in nonlinear analysis using AUTOSPCR, many degrees of freedom may not be eliminated which would have been eliminated with AUTOSPC (e.g. DOFs 456 for solid models). This could result in various fatal messages such as "USER FATAL MESSAGE 6137 (DFMNRS/D) INPUT MATRIX IS RANK DEFICIENT, RANK = 99 USER ACTION: CHECK MODEL","USER FATAL MESSAGE 5225. ATTEMPT TO OPERATE ON THE SINGULAR MATRIX KLLRH IN SUBROUTINE DCMP.", "User Warning Message 3057 Module=nliter,matrix CNVTST not positive definite","System Fatal Message 3002 illegal input to subrouti

Known Error

CR 5428

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Acoustic Analysis - GIV, HOU, PARTN - UFM 2166

Description

If an acoustic analysis model contains massless degrees of freedom and any transformation method of eigenvalue extraction is chosen (i.e., GIV, MGIV, HOU, MHOU, AGIV, AHOU) on the EIGR entry, then the run fails in the PARTN module and issues the message "USER FATAL MESSAGE 2166". This error exists in MSC/NASTRAN Version 68.0.0 on the IBM RS/6000, SGI, HP 9000/700, SUN SUNOS and SUN SOLARIS systems only. It has been corrected in MSC/NASTRAN Version 68 on all DEC, CONVEX and CRAY systems.

Known Error

CR 5428 Avoidance: A DMAP avoidance will be made available, however the simplest avoidance is to choose the Lanczos method of eigenvalue extraction.

Known Error

CR 5429

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Description

Acoustic Analysis - VELOCITY - Meaningless Answers for Complex Acoustic Results In acoustic analysis if the user requests VELOCITY=ALL in the Case Control, then "COMPLEX ACOUSTIC RESULTS" are output for the fluid grid points only and the standard complex velocity is output for the structure point. This is by design intent. However, if the user requests VELOCITY=setid and the setid contains structural and fluid points, then the program attempts to output "COMPLEX ACOUSTIC RESULTS" for the structural points and meaningless data is output. Avoidance: The only avoidances are to request VELOCITY=ALL or define a set comprised entirely of fluid points. Data recovery for structural point may then be obtained in a subsequent restart.

Known Error

CR 5431

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Heat Transfer - Superelements, IFP - UFM 2011, Misleading Message Superelements are no longer allowed in heat transfer problems (SOl 74,89,153,159). However, if the user attempts to use superelements, a misleading fatal message such as "USER FATAL MESSAGE 2011 NO PHBDY ENTRIES FOR CHBDYP" is issued. Avoidance: Use Solution 101 with app heat or remove the superelements.

Description

DMAP avoidance compile phase0, souin=mscsou, nolist, noref $ alter 32 $ type parm,nddl,logical,n, nlheat $ if ((nose > -1) and nlheat) then $ $ message //' ' $ message //'dmap fatal error: superelements are not allowed' $

Known Error

CR 5431 message //' in nonlinear heat transfer analysis' $ message //' ' $ exit $ $ endif $

Known Error

CR 5435

Product

MSC / MD Nastran

Corrected Version 68.0.1 Abstract

Description

Optimization/Design Sensitivity - PARAM,POST, DBC - Missing Output When PARAM,POST,0 is used in a SOL 200 design optimization analysis incomplete data is output to the .XDB file. The results for first design cycle are missing from the output. The result for only the last design cycle is output to the XDB file. Also, the qualifier corresponding to the last design cycle (DSN=) incorrectly identifies the data as the first design cycle. i.e. the DSN was set to 1 instead of 5. This error effects MSC/NASTRAN Version 68 on the IBM RS6000, SUN SUNOS, SUN SOLARIS, HP 9000/700 and SGI releases only. The error is corrected in Version 68 on the CRAY and all DEC releases. Avoidance: The following alter may be applied to avoid this error: compile super3 souin=mscsou noref nolist alter 88 type parm,,i,n,descycl1 $ descycl1=descycle $

Known Error

CR 5437

Product

MSC / MD Nastran

Corrected Version 68.0.1 Abstract

Description

Nonlinear Heat Transfer - SOL 153, RESTART, VIEW - Inefficient Restart In a nonlinear heat transfer restart with SOL 153 that does not change view factors; e.g., changes in boundary conditions, MSC/NASTRAN Version 68.0.0 unnecessarily recalculates the view factors . This error exists in MSC/NASTRAN Version 68.0.0 on the IBM RS/6000, SGI, HP 9000/700, SUN SUNOS and SUN SOLARIS systems only. It has been corrected in MSC/NASTRAN Version 68 on all DEC, CONVEX and CRAY systems.

Avoidance: Insert the following alter in the restart run(s):

Known Error

CR 5437 compile nlscsh souin=mscsou noref nolist alter 226 putsys(0,109) $ alter 227 putsys(1,109) $

Known Error

CR 5442

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Transient Heat Transfer - PARTN, OTIME, DLOAD - UFM 2166 In MSC/NASTRAN Version 68, if the OTIME case control option is used to reduce the output and the problem has constant boundary conditions, fixed with SPC entries, but does not have a DLOAD, then the run fails and issues the following message " USER FATAL MESSAGE 2166, MATRIX TO BE PARTITIONED IS OF SIZE *** ROWS BY *** COLUMNS."

Description

Avoidance: Define at least one time-varying load using DLOAD in conjuction with TLOAD1 or TLOAD2 entries to fix the temperatures instead of the SPC entry. DMAP avoidance: compile sedisp, souin=mscsou, nolist, noref $ alter 194,195 $ MODACC CASEDR,OL1R,YS,,,/OL1DUM,YS1,,,/APP1 $ PARTN YS1,COLP,/YQ ,,,/1 $ SDR1 USET,,UL1,,YS1,GOA,GM, , , ,/UG,, / 1/'STATICS'/-1 $ endalter $

Known Error

CR 5443

Product

MSC / MD Nastran

Corrected Version 68.0.1 Abstract

Description

Documentation - NEWS - Incomplete NEWS File The MSC/NASTRAN news file delivered with MSC/NASTRAN Version 68.0.0 on the HP, RS6000, SunOS, Solaris, and SGI is incomplete. The correct news file is listed below with "***" next to the lines omitted in the delivered news file:

Known Error

CR 5443 Welcome to MSC/NASTRAN Version 68 MSC/NASTRAN Version 68 adds the following major new capabilities: * Completely rewritten documentation, including online delivery * Shape optimization * Dynamic and acoustic optimization * Superelement optimization * Aeroelastic optimization * P-version elements and adaptivity * 3D slideline contact * Additional hyperelastic elements * Improved differential stiffness * Substantially enhanced heat transfer * Multiple boundary conditions in SOLs 101, 103, and 200 * Perform

Known Error

CR 5444

Product

MSC / MD Nastran

Corrected Version 68.0.2 Abstract

Eigenvalue Analysis - ESE, MODES - Incorrect Labeling

Description

Element Strain Energy output is incorrectly labeled when the MODES command is used. If an ESE request is made for the first mode then all ESE output is labeled as mode 1. If no ESE request is made for the first mode, then all subsequent requests are labeled as mode 0. This error is a result of an attempt to fix error 3560. The correction to 3560 has been removed in Version 68.0.2

Known Error

CR 5446

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

P-Elements - GPFORCE - Meaningless Answers If a model is comprised entirely of P-elements, a request for GPFORCE is ignored. If the model contains P and H elements an attempt is made to process the GPFORCE request for the P-element internal grid points but the results are incorrect.

Description Avoidance: Ignore GPFORCE output request for the P-element degrees of freedom. By default the IDs of the internal points are greater than 101000000. The ID of the first internal grid point may be adjusted by the user by setting SYSTEM(178) or its alias SYSTEM GNSTART.

Known Error

CR 5448

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Buckling Analysis - Superelements - Mislabeled Output

Description

Upstream eigenvector data recovery in buckling analysis incorrectly identifies the output as the first subcase. The eigenvalue label is correct.

Known Error

CR 5454

Product

MSC / MD Nastran

Corrected Version GL Abstract

Miscellaneous - SEMAP - Wrong Resource Estimates In Version 67+ systems, the disk space estimate printed in the "Estimation Data for Superelement x" generated by SEMAP is not accurate. In Version 68, for large problems, the time estimates may also be quite meaningless since these formulas are based on nonsparse methods and the default solver is the sparse solver.

Description Avoidance: There is no complete avoidance. The time estimates from the DECOMP, FBS and MPYAD modules can be used instead. The DECOMP estimate is printed by default in the Execution Summary (f04 file). The MPYAD and FBS estimates can be obtained in the f04 file by requesting DIAG 19 in the executive control section. Known Error

CR 5455

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Description

Postprocessing - OUTPUT4, ASSIGN - UWM 6445, Incorrect Format On the MSC/NASTRAN Version 67.5 SCO Unix system, if FORM=FORMATTED output is requested with the OUTPUT4 ASSIGN statement, then the OUTPUT4 file generated may not be in an 80 column format. This is most likely to occur if a nondefault number of significant digits is requested on the OUTPUT4 statement. The message "USER WARNING MESSAGE 6445, INTPTYP, INPUTT4 FAILS WITH FORTRAN IOSTAT=10006" may also appear in the OUTPUT4 file. The values generated in the OUTPUT4 file are correct. Only the format is different. Avoidance: Add RECL=80 to the ASSIGN statement.

Known Error

CR 5458

Product

MSC / MD Nastran

Corrected Version 68.1 Abstract

Description

Database - DBCRT - SFM 446 If NASTRAN attempts to lock a database file that resides on a swap partition (memory), MSC/NASTRAN Version 68 on the SUN 4 issues the message "SYSTEM FATAL MESSAGE 446 (DBCRT) SFM 446 ERROR ATTEMPTING TO CREATE A FILE (LOGICAL= xxx ) FOR DBSET xxx WITH READ AND WRITE PRIVILEGES". The following message is also written to the log file: SYSTEM FATAL MESSAGE - bio_c.opnlck.fcntl A BIO operations on a GINO file has failed. File name: "filename" File descriptor: n. errno: 22 - Invalid argument Result: -1 This error normally occurs when /tmp is defined as a swap partition and SDIR=/tmp is set in an RC file. Avoidance: There are two avoidances: 1) Direct the file to a non-swap partition. 2) Turn file-locking off by set

Known Error

CR 5462

Product

MSC / MD Nastran

Corrected Version 68.0.2 Abstract

Description

Eigenvalue Analysis - ESE, DBC, PARAM,POST - Missing Output from XDB, SWM 6065 If a modes analysis contains subcases that are not numbered sequentially from 1, then element strain energy data is not output to the XDB. The warning message "SYSTEM WARNING MESSAGE 6065 (DBC) DBCMSG ERROR MESSAGE 8 FROM SUBROUTINE DBCESE INSUFFICIENT MEMORY TO PROCESS RELATIONAL REQUIREMENTS" is issued in the output file. This error was introduced by the correction to related errors 3560 and 3841. Avoidance: Other than numbering the subcases in sequential order there is no known avoidance.

Known Error

CR 5463

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

Superelements - RESTART, CSUPER - Wrong Answers In MSC/NASTRAN, if a CSUPER entry is added to a restart run to define an image superelement, the system modes may not be recalculated which can lead to wrong answers (related to error 3514). This error is most likely to occur if there are no grid points added in the restart run. Avoidance: Add a dummy grid point to the restart run. This grid point may be constrained in all six degrees of freedom.

Known Error

CR 5465

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Miscellaneous - TABTST - System Fatal Error The example program TABTST, delivered as a utility program for MSC/NASTRAN Verion 68 and MSC/EMAS Version 3, contains a statement that is out of order. As a result of this error, the program loops until the buffers overflow and a system error occurs. Lines 216 and 317 of the TABTST source file read: IF(IN .NE. 0) GO TO 70 IUAP=0 The order of these two lines should be reversed, i.e., the correct order is:

Description IUAP=0 IF(IN .NE. 0) GO TO 70 This source file is found in: Unix: /msc68/util/tabtst.f VMS: [.UTIL]TABTST.FOR MVS: UTILSOU(TABTST) This error is present in all MSC/NASTRAN V68.0.X and MSC/EMAS Version 3.0.X systems.

Known Error

CR 5465

Known Error

CR 5467

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Buckling Analysis - EIGRL - UFM 5401, UFM 5407 When using Lanczos for solution 105 with F1 and F2 blank on the EIGRL entry, the following messages may be issued: SYSTEM FATAL MESSAGE 5407. INERTIA (STURM SEQUENCE) COUNT DISAGREES WITH THE NUMBER OF MODES ACTUALLY COMPUTED IN A (SUB-)INTERVAL

Description

SYSTEM FATAL MESSAGE 5401 (REIGL). LANCZOS METHOD IS UNABLE TO FIND ALL EIGENVALUES IN RANGE. ACCEPTED EIGENVALUES AND ADDITIONAL ERROR MESSAGES MAY BE LISTED ABOVE. USER ACTION: RERUN WITH ANOTHER METHOD OR ANOTHER SETTING ON EIGRL ENTRY. Avoidance: Specify finite values for F1 and F2. Also, it is not recommended to use system cell 146=1 to reduce scratch space without the use of finite values for F1 and F2. Another avoidance is to set SHFSCL on the EIGRL entry near the absolute value of the lowest execpted root. Please se

Known Error

CR 5468

Product

MSC / MD Nastran

Corrected Version 68.0.2 Abstract

Miscelleneous - util build - makefile.inc fails The script file delivered with MSC/NASTRAN Version 68.0.0 for the util build command is incorrect. The following messages are issued:

Description

make ARCH=sunos EXE=../exe FFLAGS=-Bstatic build make: Warning: Can't find `../makefile.inc': No such file or directory make: Fatal error in reader: makefile, line 44: Read of include file `../makefile.inc' failed

Known Error

CR 5468 This error occurs for the following machines: Sun SunOS, Sun Solaris, IBM RS/6000, HP, and SGI.

Avoidance: The corrected makefile follows: #!/bin/sh # # This is a shar file that will replace the util shell script and makefile. # # Change directory to install-dir/msc68/util and run this script using # sh, for example: # # sh util.shar # echo "Creating util" sed 's/^X//' util X#!/bin/sh X# util X# X# Known Error

CR 5469

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Complex Eigenvalue Analysis - EIGC - Wrong answers For the complex Lanczos method of eigenvalue extraction, an error exists that results in incorrect left eigenvectors.

Description

Avoidance: There is no avoidance. However, it is recommended that, if complex eigenvectors are an integral part of an analysis, the results be checked using the DMAP alter contained in Section 7.5 of the MSC/NASTRAN User's Guide for Numerical Methods, Version 67 edition.

Known Error

CR 5471

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Miscellaneous - BUFFPOOL - Confusing Messages

Description

The minimum BUFFPOOL value allowed is 15. If this minimum is violated, then in addition to the appropriate USER FATAL MESSAGE 1287, the following misleading fatal message appears:

Known Error

CR 5471 *** USER FATAL MESSAGE 1286 (SEMINT) THE VALUE SPECIFIED FOR NASTRAN SYSTEM CELL 119 IS 0 USER INFORMATION: THE VALUE MUST BE EQUAL TO -3 WHICH IS THE DEFAULT.

Known Error

CR 5475

Product

MSC / MD Nastran

Corrected Version 68.0.0 Abstract

Description

File Management Section - INIT MASTER(NORAM), OUTPUT2 - UIM 1206 The message, "USER INFORMATION MESSAGE 1206 (OUTPN2) THE DATABLOCK OQG1 /OQG IN AN OUTPUT2 REQUEST IS NOT DEFINED IN THE MSC/NASTRAN DATA DEFINITION LANGUAGE (NDDL) THIS DATABLOCK WILL NOT BE TRANSLATED TO NEUTRAL FORMAT", is improperly issued when writing to a formatted OUTPUT2 file if INIT MASTER(NORAM) is used in the FMS section in an Unstructured Solution Sequence run of MSC/NASTRAN Version 67.5. Avoidance: Do one of the following. 1. Remove the INIT MASTER(NORAM) request from the FMS Section. 2. Use a Structured Solution Sequence (e.g., sol 101) instead.

Known Error

CR 5476

Product

MSC / MD Nastran

Corrected Version 68.0.2 Abstract

Installation - IBM RS/6000 - Unreadable 1/4" Tape, error 0511-193 The IBM RS/6000 MSC/NASTRAN Version 68 1/4" tape may not be readable if the block_size is changed. The following messages may be issued.

Description

tar xf /dev/rmt0.1 the AIX 3.2.5 OS issues an error 0511-193 The 1/4" tapes must have a block_size=512, the Installation & Operation Instructions page 4 indicate that the block size can be changed with 'chdev' command. The tape drive block_size can be only changed with 'smit' command.

Known Error

CR 5476 Avoidance: Use the 'smit' command.

Known Error

CR 5482

Product

MSC / MD Nastran

Corrected Version 68.0.2 Abstract

Miscellaneous - Missing /msc68/util/archive directory The MSC/NASTRAN Version 68.0.0 system delivered on the IBM RS/6000, SUN SUNOS, SUN SOLARIS, SGI, and HP does not contain the following directory and its contents:

Description install-dir/msc68/util/archive This directory contains the source for utilities delivered in previous versions of MSC/NASTRAN. Known Error

CR 5483

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Documentation - CHBDYE - Quick Reference Guide, Wrong Table for 20 Node HEXA

Description

Remark 7. under the documentation for the CHBDYE element on Page 367 of the MSC/NASTRAN Version 68 Quick Reference Guide contains an incorrect table for the 20 node HEXA element. The 20-noded HEXA should refer to the same table as the 8-noded HEXA.

Known Error

CR 5485

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Migration - QUAD4, TRIA3, PSHELL - Convex Version 68 Only, Wrong Answers Migration of a Version 67 or 67.5 database that contains any elements that reference a PSHELL entry (i.e., QUAD4, QUADR, TRIA3, TRIAR, QUAD8, TRIA6) to MSC/NASTRAN Version 68 on the Convex computer may result in incorrect answers for plate stresses. The incorrect answers result from the fibre distance not being migrated correctly. This error only affects the unstructured solution sequences. This error may also affect a database that is transferred to another machine.

Known Error

CR 5485 Avoidance: This error is easily avoided by requesting SEMG=ALL in the Case Control. It is recommended that the first restart of any unstructured solution sequence database that contains PSHELL entries always request SEMG=ALL.

Known Error

CR 5486

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

Heat Transfer - CHBDYE, CTRIAX6 - Wrong Answers If a CHBDYE specifies a CTRIAX6 element for radiation or convection along the edge, wrong answers result because the area used for the CHBDYE option for the CTRIAX6 is incorrect.

Avoidance: Use the CHBDYG,REV option to specify the edge of CTRIAX6 element Known Error

CR 5489

Product

MSC / MD Nastran

Corrected Version 69.1 Abstract

Description

Miscellaneous - PARAM,CURV, PARAM,S1AM,1 - Wrong Answers Von Mises Strain The CURV module is used when stresses or strains are desired in the direction of the projection of the x-axis of a coordinate system onto a plate. However, the von Mises strain is incorrect if the CURV module is used with PARAM,S1AM,1. The strains in the direction of the coordinate system projection are correct, though. In addition, the von Mises stress is also incorrect if the CURV module is used with PARAM,S1M,1. Avoidance: Don't use the CURV module for strain Von Mises output. The correct value is obtained with normal strain output.

Known Error

CR 5490

Product

MSC / MD Nastran

Corrected Version GL Abstract Description

Documentation - MPC, Nonlinear Analysis - Unexpected Answers In nonlinear static analysis, the MPC has been implemented in SOL 66 and

Known Error

CR 5490 later in SOL 106 to enforce the specified MPC condition within the Subcase. In other words, the MPC constraints for each subcase are applied incrementally to the pre-existing displacements from the prior subcase and they are not enforced in the original configuration as SPCs. If the displacements resulted certain values in the first Subcase, the MPC in the second Subcase will start from the value in the first Subcase and maintain the specified MPC condition within the specified Subcase.

This may not be consistent with the SPC specification or MPC specification in linear solutions. However, the initial design in 1980 adopted this convention and we have maintained upward compatibility since. I Known Error

CR 5491

Product

MSC / MD Nastran

Corrected Version 68.0.2 Abstract

Miscellaneous - SPOINT, EMA, PARTN - Infinite CPU Loop

Description

An error in EMA in MSC/NASTRAN Version 68 may result in models with SPOINTS entering an infinite cpu loop in the PARTN module. This error only occurs when the model is not resequenced, i.e., PARAM,NEWSEQ,-1 is specified. Please also see related error 5640. Avoidance: Resequence the model. This can be accomplished by not specifying PARAM,NEWSEQ,-1 since method 3 is the default.

Known Error

CR 5494

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Nonlinear Analysis - CGAP - UFM 2025

Description

If the user defines the connecting grids in the gap element to be coincident (closer than 1.0e-3 in V68) and a coordinate system is not specified in field 9 of the CGAP entry, then the run should fail with User Fatal Message 6459. However, the Cray fails with the misleading message "USER FATAL MESSAGE 2025, UNDEFINED COORDINATE SYSTEM -1".

Known Error

CR 5494 Avoidance: Specify the coordinate system on the CGAP entry.

Known Error

CR 5495

Product

MSC / MD Nastran

Corrected Version 68.0.1 Abstract

Miscellaneous - RFALTER, COMPILE - UFM 22, ERROR IN DMAP INSTRUCTION Many of the RFAlters delivered with MSC/NASTRAN Version 68.0.0 on the IBM RS/6000, SGI, HP 9000/700, SUN SUNOS and SUN SOLARIS systems are incorrect and require minor modifications to COMPILE. The names of the RFAlters that are incorrect are:

Description

rf24d66.dat, rf26d66.dat, rf27d66.dat, rf3d66.dat, rf3d82.dat, rf47d66.dat, rf48d66.dat, rf61d66.dat, rf66d66.dat, rf5d66.dat, rf29d83.dat, rf30d83.dat, rf31d83.dat, rf48d83.dat, rf53d01.dat, rf61d01.dat, rf63d89.dat Avoidance: The error in the first nine alters listed above can be corrected by simply adding a comma at the end of the input block definition for the VECPLOT DMAP call. For example: Incorrect : VECPLOT UGV,BGPDT,EQEXIN,CSTM,CASECC,,/UGVB//0/1 $ Correct : VECPLOT UGV,BGPDT,EQEXIN,CSTM,CASECC,,,/UGVB//0/1 $ -----------

Known Error

CR 5497

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

Inertia Relief - SUPORT - Missing Output In SOL 101 with a SUPORT entry (i.e., inertia relief), the forces of single point constraint at the SUPORT entry are not output when the job is submitted with a scratch database (i.e., SCR=YES on the nastran submit command). The user should be aware that although the forces of single point constraint at the SUPORT entry has been traditionally output, that there is no physical reaction at the SUPORT point. The SUPORT entry signifies an inertia relief analysis where the applied loads are balanced by the inertia of the structure. Avoidance: The easiest avoidance is to submit the job with SCR=NO on the nastran submit command.

Known Error

CR 5499

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Heat Transfer - CHBDYG, HEXA - UFM 6193, UFM 4551 If 20 node HEXA elements are used with 8 different ambient points specified, then MSC/NASTRAN Version 68 fails with the message: USER INFORMATION MESSAGE 6193, MAXIMUM NUMBER OF BISECTIONS OR MINIMUM LOAD STEP HAS BEEN REACHED. USER FATAL MESSAGE 4551, STOPPED PROBLEM DUE TO FAILED CONVERGENCE

Description

Avoidance: It is very unusual that the user needs to specify all eight ambient points for convection, traditionally only one ambient point is used for convection. The user may avoid this error by: 1) Use 20 node HEXA and CHBDYG,AREA8 but on the CONV entry only asked for one ambient point or 8 identical ambient pointS. 2) If more ambient points are needed, then the user can use a 20 node HEXA but two CHBDYG,AREA6 need to be defined for the face convection. Please note t

Known Error

CR 5501

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

Heat Transfer - SOL 101, EMG - SFM 4276, EC 7777 If a linear heat transfer analysis is attempted in SOL 101 on MSC/NASTRAN Version 68 on the DEC ALPHA VMS or OSF/1 systems the run may fail in EMG and the message "SYSTEM FATAL MESSAGE 4276, ERROR CODE 7777" is printed to the output file. Avoidance: Execute the job in SOL 153. This requires the addition of an NLPARM Case Control and Bulk Data entry.

Known Error

CR 5503

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Single Point Constraints - SUPORT1 - Wrong Answers, Missing Fatal Message

Known Error

Description

CR 5503 If the SUPORT1 entry is incorrectly defined, i.e. it references a nonexistent grid point, the entry is ignored and no messages are output. This can lead to a singularity problem in a static analysis and no suport point being applied in dynamic analysis. This error only occurs in MSC/NASTRAN Version 68 since this entry is first introduced in Version 68. Avoidance: Correct the offending SUPORT1 entry.

Known Error

CR 5505

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

P Elements - Geometry Evaluator for Discontinuous Parameters - UFM 4659 For geometric curves and surfaces which do not have uniquely defined parameters, elements which cross the discontinuous points may be mapped incorrectly. For instance, an element edge which crosses from theta=350 to 10 on a circle may be mapped as a 340 degree arc rather than a 20 degree arc. This can result in the error:

Description

*** USER FATAL MESSAGE 4659 (EMGPSD) DURING INTEGRATION FOR ELEMENT WITH ID = BAD GEOMETRY HAS BEEN DETECTED. An avoidance is to define the curve or surface so that no discontinuous points exist, which may involve breaking up the existing entries. For instance, the above curve could be defined from -180 to +180 rather than 0 to 360.

Known Error

CR 5506

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

Documentation - GMBC - Unclear Documentation A GMBC entry with an LID=0, will not impose a nonzero enforced displacement. The appropriate degrees of freedom are constrained, but to zero instead of the displacement value specified on the entry. The program should be changed to enforce the displacement value. The documentation states that for LID>0, both SPC and SPCD entries are generated;

Known Error

CR 5506 for LID=0, only SPC entries are generated. This documentation is meant to imply that displacements would be zero and that nonzero specifications would be ignored. However, this is confusing since the SPC can also have displacement values, leading the user to believe those values would be imposed.

This error has an additional related consequence. The displacement value for the GMBC is being lost if the GMBC is part of an SPCADD, even if Known Error

CR 5511

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Aeroelastic Analysis - PARAM,OPPHIPA - Missing Output If there are extra points and the user requests normal modes output at the aerodynamic grid points using PARAM OPPHIPA, the expected results do not appear in the correct location. The eigenvector results are null for the aerodynamic grid points.

Description

Avoidance: A DMAP avoidance follows: compile opph souin=mscsou nolist noref alter 15,15 NOIS=NOMDS-NOUE $ MATGEN ,/PHPV/6/NOMDS/NOIS/NOUE $

Known Error

CR 5512

Product

MSC / MD Nastran

Corrected Version 69.1 Abstract

Miscellaneous - CORD2i, GP1 - SFM 4276, EC 46 If a CORD2i entry references a coordinate system that does not exist, then the job may fail with the following unclear message:

Description

SYSTEM FATAL ERROR 4276.GCP ERROR CODE 46 Avoidance: Other than locating and correcting the entry in error, there is no avoidance.

Known Error

CR 5514

Product

MSC / MD Nastran

Corrected Version 70 Abstract

Rigid Elements - GPSP - Wrong Answers

Known Error

Description

CR 5514 When some DOFs of a grid point are attached to rigid elements it may defeat the AUTOSPC function for the remaining DOFs. This was observed on a client problem where two rotations at one grid point were connected to a rigid element, but the third was not. It happens that this DOF has a very small stiffness due to a pin flag on a beam element. The stiffness would be identically zero except for roundoff effects. The evidence was that the eigenvector value for this point was 8 orders of magnitude larger than any other eigenvector DOF. Avoidance: A method to avoid this behavior, once observed, is stabilize this point with a stiffness value or other type of constraint. In this instance, when a ground spring of 1.E-10 was added to this DOF its eigenvector values approached zero. Another

Known Error

CR 5515

Product

MSC / MD Nastran

Corrected Version 68.0.2 Abstract

Description

Eigenvalue Analysis - EIGRL, REIGL, SYSTEM(194), FASTIO - Incorrect Eigenvectors The Lanczos method of eigenvalue extraction produces incorrect eigenvectors when the NASTRAN keyword FASTIO (alternatively NASTRAN SYSTEM(194)=1) is set to 1. This error is corrected in Version 68.0.2 to be available on all platforms. Avoidance: Do not select the FASTIO option.

Known Error

CR 5516

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

DMAP - SOL 200, COMPILER, DESOPT, DPD1 - Infinite CPU Loop An attempt to COMPILE the entire SOL 200 DMAP with the REF option specified in MSC/NASTRAN Version 68.0.1 on CRAY computers may result in an infinite cpu loop. Avoidance: Either do not request the REF option or COMPILE individual subDMAPs

Known Error

CR 5516 separately.

Known Error

CR 5527

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Documentation - DMAP Module Dictionary, OUTPUT2 - Incorrect Description

Description

The OUTPUT2 records description for records 25 and 26 are incorrect in the MSC/NASTRAN Version 67 User's Manual (Volume II Page 5.4-161). Records 25 and 26 are repeated for each column and their description needs to be the same as records 20 and 21.

Known Error

CR 5529

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Postprocessing - PARAM,POST,-2 - Extra Output If PARAM,POST,-2 is used in Version 68 of MSC/NASTRAN, then stress and force data is written to the OUTPUT2 file twice. The data is written to the OUTPUT2 file twice since both sets of data blocks OES1,OEF1 and OES1X, OEF1X are output. Avoidance: There are two avoidances.

Description

1. Include PARAM,PATVER,2.0 in the bulk data deck. 2. Use the following alter. COMPILE SEDRCVR SOUIN=MSCSOU NOREF NOLIST ALTER 307,307 IF ( POST=-2 AND APP='NLST' AND SEID=0 ) THEN $

Known Error

CR 5530

Product

MSC / MD Nastran

Corrected Version 68.0.2 Abstract

Limitation on Problem Size - SPOINT - SFM 4203

Description

A day one limit in MSC/NASTRAN limits the number of SPOINTs to 32,000.

Known Error

CR 5538

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Optimization/Design Sensitivity - DESOBJ - Untrapped User Input Error

Description

The DESOBJ case control command specifies minimization or maximization

Known Error

CR 5538 of the objective function. Section 7.3 of the Version 68 Design Sensitivity and Optimization User Guide documents TPL test problem D200X5 and indicates DESOBJ(MIN,MAX). The code should trap this input error but instead the first string, in this case MIN. Thus, DESOBJ(MIN,MAX) minimizes the function, and DESOBJ(MAX,MIN) maximizes the function. This error is fixed in MSC/NASTRAN Version 68.2 by issuing "USER WARNING MESSAGE 639 (IFP1D) YOU MAY NOT SPECIFY BOTH MAX AND MIN FOR OBJECTIVE THE DEFAULT VALUE OF MIN WILL BE USED".

Known Error

CR 5540

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Documentation - Release Notes for Version 68 The Release Notes for Version 68 contain the following errors in Chapter 4 which describes the enhancements for Design Optimization. 1. In the middle of page 84 the following line is printed and should be removed since it is not correct. The sentence prior to this sentence describes the restrictions correctly.

Description

" Superelements are not supported either in the primary model or in the auxiliary boundry models." 2. The example problem specified on page 85, 86 and 87 is in the Version 67.7 format. The converted deck for Version 68 may be found in the directory $MSC_BASE/msc68/nast68/misc/doc/desopt. The deck names are d200x3.dat d200x3s.dat.

Known Error

CR 5541

Product

MSC / MD Nastran

Corrected Version 68.0.2 Abstract

Miscellaneous - ESE, PUNCH - Missing SUBCASE ID

Description

Punched Element Strain Energy (ESE) is missing the value for the SUBCASE ID. This error occurs on all Version 68.0.0 and 68.0.1 systems. This error resulted from an attempt to correct error 3560. MSC/NASTRAN Version 68.0.2 removes the correction to error 3560 to correct this error. Please not

Known Error

CR 5541 that this error is considered fixed in 68.0.2 and later systems even though the subcase identifier is not always correct. The punched subcase identifier has the same limitations as the f06 output. Please see errors 3560 and 3841. Avoidance: Either request Version 68.0.2 or use Version 67.5.

Known Error

CR 5544

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Transient Response Analysis - SPCFORCE,MPCFORCE - Excessive CPU time If SPCFORCEs or MPCFORCEs are requested in SOL 112 and PARAM,DDRMM is 0 (default), then their computation can take a substantial amount of CPU time compared to Version 67.5. (Version 68 only). Avoidance: Do not request MPCForce or SPCForce output or insert the following DMAP alter:

Description

compile cforce souin=mscsou noref nolist alter 9,13 EQUIVX UhY/UY0/-1 $ alter 21,21 IF ( NOMXY>-1 ) MPYAD MXY1,uy,/QMX1 $ IF ( NOMXY>-1 ) MPYAD QMX1,ACCE,/QMX $ alter 23,23 MPYAD BXY1,uy,/ QBX1 $ MPYAD QBX1,VELO,/QBX $ alter 29,29 MPYAD KXY1, uy, / QKX1 $ MPYAD QKX1, disp, / QKX $ endalter

Known Error

CR 5545

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Documentation - PARAM,POST,-2 - OGPFB1 Not Written to OUTPUT2 The Grid Point Force datablock is not output to the OUTPUT2 file when PARAM,POST,-2 is specified, even though the documentation claims otherwise. Furthermore, attempting to force this output by including PARAM,OGPF,YES does not work.

Known Error

CR 5545 Avoidance: For Version 68 use the following DMAP avoidance, COMPILE sedrcvr souin=mscsou nolist noref alter 270,270 IF ( OGPF='YES' ) THEN $ ENDALTER

For version 67.5 include the following DMAP alter COMPILE sedrcvr souin=mscsou nolist noref alter 260,260 IF ( OGPF='YES' ) THEN $ ENDALTER

Known Error

CR 5549

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Postprocessing - ESE, OUTPUT2, PARAM,POST,-2 - Wrong Datablock Output In solution 103, PARAM,POST,-2 OUTPUT2s the LAMA datablock as OLB. This causes problems for the SDRC Dataloader program. The LAMA table is only needed if element strain energy output is requested for SDRC/IDEAS. This error occurs in Version 67.5 and 68. Avoidance: The error may be avoided by using the following DMAP alters.

Version 67.5 DMAP avoidance:

Description

compile sedrcvr souin=mscsou nolist noref alter 271,271 $ v67.5 matmod olbm,,,,,/lama,/13 $ output2 lama,onrgy2//otape2/ounit2//omaxr $ ------------------------------------------------------Version 68 DMAP avoidance: COMPILE SEMODES SOUIN=MSCSOU, NOLIST, NOREF $ ALTER 115 $ CALL DBSTORE LAMA,,,,//0/0/'DBALL'/0 $ COMPILE SEDRCVR SOUIN=MSCSOU, NOLIST, NOREF $ ALTER 93,93 $ CALL SDRCFIX OUGV1/DUM/OTAPE2/O

Known Error

CR 5554

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

P-Elements - EMA, CORDi - Wrong Answers If p-elements are mixed with h-elements and grid points that are attached to the h-elements have an output coordinate system specified other than the basic coordinate system, then the transformation to the global coordinate system is not performed. This leads to an incorrect stiffness matrix and wrong answers. Avoidance: If h-p elements the output coordinate system should be the basic system throughout the model.

Known Error

CR 5555

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

Superelements - CORD1 - UFM 2004 CORD1-type coordinate systems cannot be used as either the location coordinate system or the output coordinate system for grids in one superelement if the grids used to define the CORD1 coordinate system belong to another superelement. The job will end with one of the following USER FATAL MESSAGES: 2004, 2006, 2104. Similarly, CORD1-type coordinate systems should not be referenced on SURFACE or VOLUME GPRSTRESS requests if superelements are present. Otherwise, GPSTRESS results will be missing for superelements which do not recognize the coordinate system and USER WARNING MESSAGE 4598 will be issued.

Avoidance: Use CORD2 type description. Known Error

CR 5556

Product

MSC / MD Nastran

Corrected Version 2004 Abstract Description

Documentation - Design Optimization User's Guide - Incomplete Data Listing Listing 7-7 in the Design Optimization User's Guide for Version 68 is missing a few lines of input data. This data is the Von Mises stress constraint data for the analytic boundary shapes example in Section 7.6 of the guide.

Known Error

CR 5556 Avoidance: Refer to the TPL deck D200AM3.dat for the correct listing. The documentation will be updated in Version 69. A new user's guide based on MSC.Nastran 2004 has been developed and is now available electronically and will soon be in hardcover. EHJ 1/2004

Known Error

CR 5557

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

Nonlinear Transient Analysis - MCE2, MPC, SOl 159 - UFM 5423 Solution 159, nonlinear transient heat transfer, with a stuctural problem that contains an MPC fails with the following fatal message "USER FATAL MESSAGE 5423---ATTEMPT TO ADD INCOMPATIBLE MATRICES, (SADD5)". This message is output from the MCE2 module in subdmap SEMR2. The same problem runs to completion in SOL 129 with a correct solution. Avoidance: Use solution 129 for the nonlinear structural problems.

Known Error

CR 5560

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Postprocessing - PARAM,POST,-1/-2 - UIM 1206 and Missing Output When using param,post,-1 or -2, param,patver,2.0 and/or param,ougcord,basic, and form = formatted on the ASSIGN OUTPUT2 statement the following message is issued:

Description

0*** USER INFORMATION MESSAGE 1206 (OUTPN2) THE DATABLOCK ***/*** IN AN OUTPUT2 REQUEST IS NOT DEFINED IN THE MSC/NASTRAN DATA DEFINITION LANGUAGE (NDDL) THIS DATABLOCK WILL NOT BE TRANSLATED TO NEUTRAL FORMAT Avoidance: Insert the following DMAP Alter: compile sedrcvr souin=mscsou,nolist,noref $ alter 74,74 $ output2 ougv1pat//otape2/ounit2//omaxr/'oug' $ alter 78,78 $

Known Error

CR 5560 output2 bophig//otape2/ounit2//omaxr/'oug' $ alter 81,81 $ output2 bougv1//otape2/ounit2//omaxr/'oug' $

Known Error

CR 5563

Product

MSC / MD Nastran

Corrected Version 68.0.2 Abstract

Miscellaneous - ACCT=YES - Missing Data, Will Not Create New File. The MSC accounting function in the nast68 script, which is called out on the submittal line with the command acct=yes, has several errors: 1) The username, product, and version are blank in the accounting file. 2) If the acct file does not exist, the script does not create a new acct/mscYYMM.acct file.

Description

Avoidance: To correct the second item comment out the following lines in the nast68 script: # test -w "$MSC_ACCT" || { # echo "No permission to write accounting file $MSC_ACCT" # MSC_ACCT="" #} or create a new accounting file every month. However, the best alternative is to use the Nastran 68.0.2/Emas 3.0.2 script.

Known Error

CR 5565

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Miscellaneous - OUTPUT2 - Tables Misidentified as Scalar Matrices Some tables may be misidentified as scalar matrices during OUTPUT2 neutral processing. The error occurs when the datablock trailer meets all three of the following conditions:

Description

1. The trailer word 4 is greater than or equal to 13. 2. The trailer word 2 is greater than 0 OR trailer word 3 is greater than 0. 3. The trailer word 5 is between 1 and 4, inclusively. Avoidance: There is no avoidance.

Known Error

CR 5567

Product

MSC / MD Nastran

Known Error

CR 5567

Corrected Version 70 Abstract

Optimization/Design Sensitivity Analysis - SOL 101, AXMPR1- SFM 3001

Description

If auxiliary models are defined in SOLs 101 through 159 then the run will fail with SYSTEM FATAL MESSAGE 3001 being issued from the AXMPR1 module. Avoidance: Remove all auxiliary models.

Known Error

CR 5568

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Documentation - V68 Quick Reference Guide - PARAM,PATVER

Description

The MSC/NASTRAN Version 68 Quick Reference Guide documentation for PARAM,PATVER,2.0 incorrectly indicates that the OES1X datablock is output. This error is corrected in the 2nd printing of the Version 68 Quick Reference Guide.

Known Error

CR 5569

Product

MSC / MD Nastran

Corrected Version 68.1 Abstract

Miscellaneous - MACOFP - Infinite Loop If spill logic is necessary in the MACOFP module, then the module may go into an infinite cpu loop. Note that the MACOFP module is only used in user DMAPs.

Description

Avoidance: Because the VAX has a smaller default buffsize then other systems, this error has only been observed on the VAX VMS system. The avoidance is to increase buffsize. A value of 4 times the default is suggested.

Known Error

CR 5570

Product

MSC / MD Nastran

Corrected Version Abstract

Description

Old Design Sensitivity - CBEND, DVSET - UFM 316, UFM 2040, SFM 5037 According to Remark 7 in the MSC/NASTRAN Quick Reference Guide for the DVSET entry there is a way to perform design sensitivity analysis on the BEND element using the original design sensitivity capability of SOl 53. However, if this is attempted, the analysis fails with the following fatal messages: 1. "USER FATAL MESSAGE 316 (IFPDRV) ILLEGAL DATA ON BULK DATA CARD

Known Error

CR 5570 DVSET 111 SORTED CARD COUNT = 3" 2. "SYSTEM FATAL MESSAGE 5037 UNEXPECTED EOR READING DVSET CARDS OFF EDT-DSTA MODULE TERMINATED IN DSTA" 3. "USER FATAL MESSAGE 2040, SINGULAR MATRIX FOR ELEMENT 1" Avoidance: Replace the BEND element with multiple BAR elements.

Known Error

CR 5571

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

P-Elements - GPOA, HEXA20, PENTA15, TETRA10 - UFM 6390 If h-elements with midside nodes (HEXA20, PENTA15, TETRA10) occur in a model with p-elements, the analysis fatals and the message "USER FATAL MESSAGE 6390, (GPOA), ELEMENT ID = *** TYPE HEXA20 OR PENTA15 AND/OR TETRA10 ARE NOT SUPPORTED IN PELEMENT ANALYSIS" is output. The analysis should be allowed to proceed if the midside nodes do not occur on the edge of a p-element. In addition, the error message reports the Property ID instead of the Element ID. Avoidance: Remove the midside nodes from the aforementioned helements.

Known Error

CR 5572

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

P-Elements - FEFACE, GMSURF - SFM 3007 When the SURFID field of the FEFACE entry is specified and there are no corrosponding GMSURF entries, then the following poor message is issued, "SYSTEM FATAL MESSAGE 3007 MODULE = GP0 ILLEGAL INPUT TO SUBROUTINE EVLCRD FATAL ERROR". Avoidance : Remove the SURFID fields on the FEFACE entries if the corrosponding GMSURF entries do not exist.

Known Error

CR 5573

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Nonlinear Analysis - RESTART - Inefficient Restart In nonlinear analysis restarts, some residual error may be inadvertently carried over from the previous run. This may cause extra iterations to convergence when compared to an equivalent run that executes the identical load path in a single run.

Description

Avoidance: Apply the following DMAP alter: COMPILE NLSTATIC SOUIN=MSCSOU NOLIST NOREF ALTER 307,307 $ V681T1 MPYAD KGG0,UGNH,PGNL/QQGNX $ UPARTN USETNL,QQGNX/,QQSVI,,/'G'/'F'/'S'/1 $ SET F-SET COMPONENTS UMERGE1 USETNL,,QQSVI,,/QQGNI/'G'/'F'/'S'/1 $ TO ZERO MAY 23, 1995

Known Error

CR 5575

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Documentation - PARAM, POST,-1,-2, PARAM,CHECKOUT - Incorrect Documentation

Description

In MSC/NASTRAN Version 68, geometry OUTPUT2 datablocks for PARAM,POST,-1 or PARAM,POST,-2 are written to the unit specified by PARAM,OUNIT1 which defaults FORTRAN unit 11 whenever PARAM,CHECKOUT,YES is used. This is contrary to Quick Reference Guide documentation for PARAM,POST which states that the geometry datablocks are written to the unit specified by PARAM,OUNIT2 which defaults to FORTRAN unit 12.

Known Error

CR 5578

Product

MSC / MD Nastran

Corrected Version 68.0.2 Abstract

Installation - Unable to Locate the Decompression Program

Description

The local tape option cannot be used to install MSC/NASTRAN V68 or MSC/EMAS V3 on a Cray system where the tape mount daemon, tpdaemon, is running. The tape mount deamon runs on ALL Cray mainframe systems; it is an option on EL systems. Instead, the tape is mounted using tpmnt and used by

Known Error

CR 5578 mscsetup as a local disk archive file. Avoidance: The commands to load MSC/NASTRAN V68 or MSC/EMAS V3 when tpdaemon is running are: # Mount the tape files. Note: must be 1 to 6 characters. $ rsv TAPE $ tpmnt -l nl -v -p /tmp/MSC68.1 -q 1 -b 10240 -g TAPE -r out $ tpmnt -l nl -v -p /tmp/MSC68.2 -q 2 -b 10240 -g TAPE -r out -w # Extract mscsetup et al $ tar xvf /tmp/MSC68.1 # Run mscsetp $ sh mscsetup . . . 3 -1 OR NOQMG>-1) AND NOT(APP='CEIGEN') AND NOT(NONLNR) ) THEN $

Known Error

CR 5583

Product

MSC / MD Nastran

Corrected Version 68.0.2 Abstract

Description

Miscellaneous - Install Script, NFS - No Read/Write Access to Filname++ The nastran script in 68.0.0 and 68.0.1 uses the plus sign, `+', as a delimiter when processing the command line. Unfortunately, this character is typically used by NFS on the Cray to generate temporary filenames. As a result, filenames using the plus sign are mangled on the Cray. This error has been corrected in Version 68.0.2 by using the ampersand, `&', as the delimiter. Avoidance: There is no avoidance.

Known Error

CR 5586

Product

MSC / MD Nastran

Corrected Version 68.1 Abstract

Description

Miscellaneous - VECPLOT, PARAM,GRDPNT - Wrong Answers for Resultants Setting PARAM,GRDPNT to other than 0 may result in wrong answers for the OLOAD RESULTANT and SPCFORCE RESULTANT in MSC/NASTRAN Version 68. This error may also cause VECPLOT option 4 to give incorrect Rigid Body Vectors, which can cause "clean" models to fail rigid body motion checks. Such checks are performed, for example, in the model checkout alters (checka) in the SSSALTER directory. This error may also cause wrong answers in Inertia Relief (PARAM,INREL,-1 or INRLM,1) since the vecplot module is utilized in inertia relief for computation of rigid body motion vectors. Avoidance: There is no known avoidance.

Known Error

CR 5590

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

P-Elements - EMA - Wrong Answers If p-elements are mixed with scalar h-elements such as CELASi, then the scalar elements are not assembled to the global matrix and wrong answers occur. Avoidance: Use non scalar elements such as the CROD in place of scalar elements.

Known Error

CR 5591

Product

MSC / MD Nastran

Corrected Version 68.2.0 Abstract

Description

P-Elements - GMLOAD, GMSURF, GMBC - Wrong Answers, UWM 6498 When doing p-element analysis with MSC/NASTRAN Version 68 on CRAY computers, incorrect results occur for problems with loads defined with convective coordinate systems. The incorrect results are preceded by the USER WARNING MESSAGE 6498 which indicates that the equation evaluator is having difficulty converging. Avoidance: Don't define loads with convective coordinate systems.

Known Error

CR 5596

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Miscellaneous - PARAM,CURV,1 - USER WARNING MESSAGE XXXX. (CURVIT1) If PARAM,CURV,1 is specified to request element stress and/or strain output to be computed in a material coordinate system or to interpolate the data to grid points in a run with fewer than 3 elements that are not colinear, then the following unnumbered message occurs:

Description

USER WARNING MESSAGE XXXX. (CURVIT-1) LOCAL INTERPOLATION USING INDEPENDENT VALUES WITHIN RANGE OF THE 0-TH SORTED ORDER GRID ID INVOLVED WITH RESPECT TO MATERIAL COORDINATE SYSTEM ID = 1 CAN NOT BE COMPLETED. ILL-CONDITION MAY HAVE RESULTED FROM ALIGNMENT OF INDEPENDENT VALUE COORDINATES. OUTPUT FOR THE GRID ID IN QUESTION WILL NOT APPEAR. Avoidance: Specify PARAM,OG,-1.

Known Error

CR 5597

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Documentation - CHBDYE - Quick Reference Guide

Description

Remark 3 on page 366 of MSC/NASTRAN Version 68 Quick Reference Guide

Known Error

CR 5597 should be removed because the front face of a surface element is not always associated with the outward normal vector. The user should consult the table on Page 367 of the Guide to determine the normal orientation.

Known Error

CR 5598

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

DBC - PARAM,POST,-1 PARAM,PATVER,2.0 - Missing Displacements in OUTPUT2 file In Buckling Analysis (SOL 105) when DISP=ALL is used along with PARAM,POST,-1 and PARAM,PATVER,2.0 the OUTPUT2 file (fort.12) does not contain the displacement information for the buckling modes.

Description

Avoidance: The avoidance is to include the following alter, SOL 105 COMPILE SEDRCVR SOUIN=MSCSOU ALTER 208 $ OUTPUT2 OUGV1//OTAPE2/OUNIT2//OMAXR $

Known Error

CR 5599

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

Optimization/Design Sensitivity - DVPREL1 - Wrong Answers If a DVPREL1 bulk data entry has a COEFi value of 0.0 and there are also DVPREL2 entries, wrong answers are produced for sensitivity results and therefore for optimization. A similar error is produced if a DVPREL1 entry references more than one design variable and there are DVPREL2 entries. This is a Version 68 only. Avoidance: An avoidance for the COEFi= 0.0 is to delete the 0.0 values or replace them with very small values. There is no avoidance for the multiple desgin variable reference.

Known Error

CR 5601

Product

MSC / MD Nastran

Corrected Version 68.0.2 Abstract

Miscellaneous - RFLAG.V68 - Fatal Messages

Known Error

CR 5601

Description

In MSC/NASTRAN 68.0.0 there are two versions of the Lagrange Multiplier Technique alters on the delivery tape. One is in the SSSALTER directory and an old noncurrent copy is in the TPL. Avoidance: Use the alter in the SSSALTER library.

Known Error

CR 5615

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

Postprocessing - OUTPUT2, .XDB - Missing Eigenvalue Data When p-elements are used in normal modes, and stress/strain output is requested, the eigenvalue data is missing from the OES1 data block in the OUTPUT2 and .XDB files. This means that post-processors do not have access to the eigenvalues. Avoidance: There is no avoidance.

Known Error

CR 5616

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

DMAP - DIAGONAL - UFM 5250 The DIAGONAL module issues the message "USER FATAL MESSAGE 5250, RAISING A NEGATIVE NUMBER TO A NON-INTEGER EXPONENT IS NOT ALLOWED" incorrectly for integer exponents when the matrix element is negative. The message should only be issued for exponents which are not integers. Avoidance: There is no known avoidance.

Known Error

CR 5620

Product

MSC / MD Nastran

Corrected Version 70 Abstract

Description

Miscellaneous - INPUTT2, PARAM,POST - SFM 6551 (INPTX2) "SYSTEM FATAL MESSAGE 6551(INPTX2) A READ ERROR WAS DETECTED ON UNIT XX DURING BINARY INPUTT2 PROCESSING" may be encountered on MSC/NASTRAN Version 68.0.2 on CONVEX computers when reading unformatted OUTPUT2 data. Avoidance: OUTPUT2 and INPUTT2 the necessary data specifying "FORMATTED"

Known Error

CR 5620 on the associated ASSIGN statement.

Known Error

CR 5621

Product

MSC / MD Nastran

Corrected Version GL Abstract

Static Analysis - BEAM - Missing Force Output for BEAM

Description

If a BEAM's forces are zero, the force results for end A of the BEAM may not be output. This has only been observed on the CONVEX, however, there is the potential for this error to occur on other machines. Avoidance: There is no avoidance.

Known Error

CR 5622

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Documentation - PBEAM - Incorrect Coordinate System

Description

Remark 10 under the documentation for the PBEAM entry is incorrect. The remark indicates that the I1, I2 and I12 values are the Izz(elem), etc. The reference to (elem) is not correct. The I1, I2 and I12 are determined with respect to the neutral axis not the element (shear center) coordinate system. This documentation error is addressed in the 2nd printing of the Version 68 Quick Reference Guide.

Known Error

CR 5626

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Nonlinear Analysis - SPARSE - UWM 4698 When running sparse decomposition in solution 106, the message:

Description

USER WARNING MESSAGE 4698, STATISTICS FOR DECOMPOSITION OF MATRIX ***. THE FOLLOWING DEGREES OF FREEDOM HAV FACTOR DIAGONAL RATIOS GREATER THAN *** OR HAVE NEGATIVE TERMS ON THE FACTOR DIAGONAL" does not list the grids/dofs corresponding to the negative diagonal terms.

It will however list the DOF's corresponding to factor diagonal ratios greater than MAXRATIO. Avoidance: Run the job with SPARSE=1 to identify the negative diagonal

Known Error

CR 5626 terms.

Known Error

CR 5627

Product

MSC / MD Nastran

Corrected Version 68.1 Abstract

Description

Superelements - CORD1S, CORD2S - UFM 2104 If superelements are used in conjunction with spherical coordinate systems (i.e. CORD1s or CORD2S) in MSC/NASTRAN Version 68, then the following fatal message occurs, "USER FATAL MESSAGE 2104, UNDEFINED COORDINATE SYSTEM".

Avoidance: Remove the Superelements, use a non-spherical coordinate system or use a prior version of MSC/NASTRAN. Known Error

CR 5633

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Online Documentation - Ghostview - Collection NAME.cfg Failed to Open MSC/NASTRAN Encyclopedia sometimes issues messages such as "... collection NAME.cfg failed to open", if there are other unrelated .cfg files in the filesystem. Avoidance: These messages have no consequence to the operation of the Encyclopedia and can be safely ignored.

Known Error

CR 5636

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Cyclic Symmetry - PARAM, AUTOSPC, YES - Wrong Answers

Description

If PARAM, AUTOSPC, YES is specified in cyclic symmetry analysis with dihedral symmetry (STYPE="DIH" on the CYSYM Bulk Data entry), then grids and components specified on the CYJOIN or CYAX Bulk Data entries may be constrained improperly by the AUTOSPC operation. PARAM, AUTOSPC, YES is the default in SOLs 81, 82, 83, 88, 114, 115, and 118; and NO is the default in SOLs 47, 48, 77,

Known Error

CR 5636 and 78. This is an error in Versions 67, 67.5, 67.7, 67R2 and 68 only. Note that it is the design intent of the GPSP module to not constrain any degrees of freedom on the CYJOIN entry. It is the responsibility of the user to constrain any singular degrees of freedom on the CYJOIN entry. For example, in a solids model it is the user's responsibility to constrain the rotational degrees of freedom on the CYJOIN

Known Error

CR 5639

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

P-Elements - VECPLOT - Wrong Answers for Moment Resultants Whenever there is a CID for edges or faces of p-elements, the OLOAD and SPCFORCE RESULTANTS for the moments are incorrect. See related error report 5586.

Description Avoidance: Other than not specifying a CID for edges and faces of the pelements, there is no avoidance.

Known Error

CR 5640

Product

MSC / MD Nastran

Corrected Version 68.0.2 Abstract

Sequencer - SEQP , SPOINT - Wrong Answers In MSC/NASTRAN Version 68.0.0, when the stiffness matrix is dense, wrong answers may result if there are scalar points (SPOINT) in the model. Wrong answers can only occur if structural elements attach to the SPOINTs. Thus, models that include SPOINTs only to be used as q-set degrees of freedom need not be concerned. This error is related to error 5491.

Description Avoidance: Replace all SPOINTs with GRID points. (If the SPOINTs were used for beam warping degrees of freedom, constrain D.O.F.s 23456.)

Known Error

CR 5642

Product

MSC / MD Nastran

Corrected Version 70 Abstract

Documentation - Linear Static Analysis User's Guide - Incorrect PBEAM entry

Description

The PBEAM entry shown in Listing 4-4 (page 87) of the MSC/NASTRAN Linear

Known Error

CR 5642 Static Analysis User's Guide is incorrect for the example beam. Note that the displacement output shown on page 88 will change with the modified PBEAM entry. Avoidance: Replace the PBEAM entry shown in Listing 4-4 with the following PBEAM entry.

PBEAM 11 21 12.000 56.000 17.000 3.930 -3.000 .867 -3.000 4.867 3.000 4.867 3.000 .867 YES .100 10.830 45.612 13.847 3.201 -2.850 .824 -2.850 4.624 2.850 4.624 2.850 .824 YES .200 9.720 36.742 11.154 2.579 -2.700 .780 -2.700 4.380 2.700 4.380 2.700 .780 YES .300 8.670 29.232 8.874 Known Error

CR 5644

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Online Documentation - Iview - mscdoc1 Script Only Allows Default Iview File When using the MSC/NASTRAN Online Documentation, the SGI/IRIX systems attempts to use the default Iview file even if there is an Iview file in the user's HOME directory and even if the MSCDOC_IVIEWFILEDIR is explicitly specified.

Avoidance: Comment out lines 152-160 from the script $MSC_DOCBASE/bin/mscdoc1. Known Error

CR 5646

Product

MSC / MD Nastran

Corrected Version 68.1 Abstract

Miscellaneous - FFIO has problems with nqs and nast68 script

Description

There are two problems that can prevent MSC/NASTRAN Version 68.0.2 running under NQS from using EIEIO. The first error involves NQS generated filenames. These filenames include a `.', e.g., `/tmp/nqs.++++107Yo'. When nastran generates unique filenames, it adds `N$$.sec' where $$ is the pid and sec is the seconds in the time, so the complete filename looks like `/tmp/nqs.++++107Yo/N13634.17.SCRATCH'.

Known Error

CR 5646 Unfortunately, EIEIO fails to recognize that a name of this pattern should be matched by the string '*.SCR*'. The second problem occurs when the FF_IO_OPTS and FF_IO_DEFAULT are set in both an RC file and as environmental variables, the RC file values override the environmental variables. In Version 67.5, the environmental variable overrode the RC file variables (this is the correct beh

Known Error

CR 5647

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Nonlinear Slide Line Analysis - BCONP - UFM 6309 The message "USER FATAL MESSAGE 6309, (BGLSCW ) GRID POINT ID = xxxx REFERRED IN BOTH SLAVE AND MASTER REGIONS FOR BCONP ENTRY ID = yyyy USER ACTION : DO NOT INCLUDE A GRID POINT IN SLAVE AND MASTER REGIONS.", may incorrectly occur with slidelines when one of the following 2 conditions are met:

Description

1) Two or more master segments overlap (i.e., share one or more grids). 2) One master is connected to more than one slave segment on various BCONP entries, and there are two or more slave segments that consist of a single point (i.e. "a slave point" instead of a "slave segment"). Avoidance: The only known avoidance is to eliminate the occurrence of the conditions above.

Known Error

CR 5650

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Plotting - XYPLOT - UWM 979, Missing Plots Requests

Description

In MSC/NASTRAN Version 68, if more than three XYPLOTs are requested for any given frame, then the message, "USER WARNING MESSAGE 979, AN XYOUTPUT REQUEST FOR POINT OR ELEMENT ID * -****- CURVE IS BEING PASSED OVER. THE ID COULD NOT BE FOUND IN DATA BLOCK ***", may be issued and some requested plots are skipped.

Known Error

CR 5650 Avoidance: When using XYPLOT do not request more than three plots per frame.

Known Error

CR 5654

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Nonlinear Buckling - Missing Eigenvector Output There is no way to get the nonlinear buckling eigenvectors printed or sent to an output2 file. In the buckling restart with PARAM,BUCKLE the request for any output2 data via PARAM,POST is ignored. Avoidance: Apply the following dmap alter:

Description

compile nlstatic, nolist noref$ alter 530 equivx ophig/ougv1/always $ alter 543 output2 ougv1//0/ounit2//omaxr $ ofp ophig// $ Put $ in col 1 if don't want eigenvector to be printed

Known Error

CR 5656

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Description

Documentation - GRDSET - SEID Field is Not a Documented Option The GRDSET bulk data entry can be used to define the default values of the CP,CD,PS and SEID fields for all GRID entries in the model. However, all versions of the Quick Reference Guide and the User's Manual give no indication that the GRDSET entry may be used for the SEID field. The 2nd printing of the Version 68 Quick Reference Guide has been updated to reflect this capability.

Known Error

CR 5660

Product

MSC / MD Nastran

Corrected Version 68.1 Abstract Description

Case Control - GPFORCE - Missing output When a GPFORCE = (Set ID) is used, then there may be missing GPFORCE output in the .F06 and the punch file.

Known Error

CR 5660 Avoidance: Specify GPFORCE=all. Best way to get around this error is to specify dummy temperature load as follows; case control card, temp(load) = setid bulk data card, tempd, setid, tref (see field 8th of mat1 card )

Known Error

CR 5663

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

Elements - QUAD8, TRIA6 - Wrong Mass Matrix If midside nodes are used on QUAD8 or TRIA6 elements and a midside node is specified after an omitted midside node, then the mass matrix for the element is incorrect. The error for the individual element may be significant, up to 25%. However, in most models where midside nodes are only deleted in a few percent of the total elements, for example in a transition region, the error in the individual element should not significantly affect the results. Avoidance: Do not specify a midside node after an omitted midside node.

Known Error

CR 5664

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Restarts - PLOTEL - Inefficient Restarts If a PLOTEL is the only modification in a restart, the solution will be unnecessarily re-executed.

Description Avoidance: Other than not modifying the PLOTEL, there is no other avoidance. Known Error

CR 5666

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Miscellaneous - File Locking - Job Hangs MSC/NASTRAN V68 and MSC/EMAS V3 may hang in link 1 if file locking is enabled under SunOS 4.1.3_U1 (a.k.a. Solaris 1.1.1). It is not known if the problem is present in both Version A and Version B or if it is restricted to only one of these versions.

Known Error

CR 5666 Avoidance: Disable file locking by setting the following system cell: NASTRAN SYSTEM(207)=1 This system cell can be set in an RC file, the architecture RC file is preferred. The name of the architecture RC file is (/conf/sunos/nast68rc, /conf/sunos/emas3rc). Alternatively, each affected user's home RC file may be set. The name of the home RC file is ($HOME/.nast68rc, $HOME/.emas3rc). This may be preferred in a file server environment where only a few of the SunOS systems using MSC/NASTRAN V68 or MSC/

Known Error

CR 5667

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Optimization/Design Sensitivity - Acoustics, MODACC - SFM 3001 If ANALYSIS=STATICS or SAERO is requested in SOL 200 along with an acoustic analysis with ANALYSIS=MFREQ or MTRAN, then the run fails and the message "SYSTEM FATAL MESSAGE 3001" is output in the MODACC module.

Description

Avoidance: Insert the following DMAP alter: COMPILE PHASE0 SOUIN=MSCSOU NOREF NOLIST ALTER 374,374 IF ( FSCOUP AND NOT(DESOPT) AND (STATICS OR CYCLIC OR NLHEAT OR AERO) ) THEN $

Known Error

CR 5668

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

Optimization/Design Sensitivity - UMERGE1 - UFM 1126 on data block K4DD If structural damping is defined in SOL 200 then "USER FATAL MESSAGE 1126" may be issued for data block K4DD in module UMERGE1 in subDMAP DPD1. UFM 1126 may also be issued for data block GOD if an o-set exists and for data block GMD if multipoint constraints (rigid elements or MPCs) are present.

Avoidance: Insert the following DMAP Alter.

Known Error

CR 5668 COMPILE DPD1 SOUIN=MSCSOU NOREF NOLIST ALTER 7 FILE K4DD=OVRWRT/GOD=OVRWRT/GMD=OVRWRT $

Known Error

CR 5672

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Description

Miscellaneous - UFM 307 - Bad Error Message If a 0 (zero) character or blank is placed in front of a bulk data entry, then USER FATAL MESSAGE 307 is issued. However, the bulk data entry name listed in the message is an unintelligible series of characters. See also see 1-10515201. Avoidance: There is no avoidance.

Known Error

CR 5673

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

DMAP - REIGL - Bad Message

Description

IF the third input datablock to REIGL is missing, an erroneous message is issued. The message indicates that an output datablock with name of **** is missing. This error only occurs in user DMAPs. Avoidance: There is no avoidance.

Known Error

CR 5674

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

Optimization - PARAM,DSNOKD - Wrong Answers The differential stiffness sensitivity calculation is performed under the assumption that all the displacements are enforced (i.e,, the change in the stiffness matrix due to the changes in the displacements are not computed). In almost all cases, this is a very poor assumption. Buckling sensitivity for an Euler column can be in error by a factor of 1000, and have the wrong sign. Avoidance: It is recommended that PARAM,DSNOKD always be set to 0.0. This neglects the differential stiffness sensitivity in the buckling sensitivity

Known Error

CR 5674 calculation. For statically determinate structures, this is exact. For almost all structures, this is not a bad approximation and is better than including the incorrect calculation. The default for PARAM,DSNOKD has been changed to 0.0 in Version 68.2.

Known Error

CR 5678

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Optimization/Design Sensitivity - OFREQ, DSAH - SFM 4276 EC 1409 If an OFREQ request is present in the Case Control section and dynamic sensitivity/optimization is being performed, then the run fails in the DSAH module with the message "SYSTEM FATAL MESSAGE 4276 ERROR CODE 1409". (V68 only) Avoidance: Insert the following DMAP alter:

Description compile fea, souin=mscsou, nolist, noref $ alter 257 $ equivx fol1/fol/-1 $ alter 314 $ equivx fol1/fol/-1 $ endalter $ Known Error

CR 5682

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Optimization/Design Sensitivity - DESMAX set to late for CALL SETDROPT

Description Known Error

CR 5694

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Composites - PCOMP - Missing Output

Description

If data other than NO or YES is entered in the SOUT field of the PCOMP entry, instead of fataling, the default of not writing results is used.

Known Error

CR 5696

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Superelements - Case Control - Poor Messages

Known Error

Description

CR 5696 If the Case Control references a nonexistant superelement, the program does not issue a fatal message, but continues processing. It then becomes very difficult to determine the cause of subsequent error messages indicating missing datablocks. Avoidance: Reference only existing superelements in the Case Control.

Known Error

CR 5699

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

P-Elements - EMG - UWM 6498 In some models, the elements are being mapped to the geometry incorrectly. The warning message:

Description

*** USER WARNING MESSAGE 6498 (EQUATION Evaluator, Get Surface Parameter) GEOMETRY API MESSAGE FOLLOWS. USER INFORMATION: Point not close enough. Point: (-1.414214, 1.414213, 0.000000). Projection Parameters: 1.000000, 0.786178. Distance: 2.235370. Surface: 3. Point/Grid Id: 102. followed by the error message: *** USER FATAL MESSAGE 4659 (EMGPSD) DURING INTEGRATION FOR ELEMENT WITH ID = 1 BAD GEOMETRY HAS BEEN DETECTED. is output if the element mapping is bad enough. Avoidance: The workaround is to split the curves or surfaces int

Known Error

CR 5700

Product

MSC / MD Nastran

Corrected Version Abstract

P-Elements - ADAPT - Poor Answers

Description

When the error is calculated for a p-element, the energy of each function at the current p-level should be considered. However, only the last function for each edge, face, and body is being considered. This is not a problem

Known Error

CR 5700 for edges which only have one function for each p-level, but the other terms should be considered for the faces and body. The result is that element errors may be higher than reported leading to a premature convergence. Avoidance: There is no workaround.

Known Error

CR 5703

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Documentation - User Modifiable NASTRAN - Incorrect Installation Instructions The appendices of the Installation and Operation Instructions describe the installation procedure for User Modifiable MSC/NASTRAN Version 68. The following errors have been detected in this documentation: SGI(IRIX) : APPENDIX C After all 5 steps are done final executable is named UMNASTRAN2 instead of NAST68. Therfore page C-6 section C.4 item 2 should read nastran link16b exe=./UMNASTRAN2 IBM RS/6000 : APPENDIX C

Description Page C-5, section C.3, item 2 the compile command is incorrect. In item 2 the following command should be issued. link.sh xmplbd.f For section C.3, item 3 the commnad should read nastran link16a exe=./UMNAST68 Page C-6, section C.3, item 4 the commnds should be mv link16a.pch newdriver.f Known Error

CR 5708

Product

MSC / MD Nastran

Corrected Version 69.0.4 Abstract

Complex Eigenvalue Analysis - EIGC, Massless DOF - Wrong Answers

Description

In a direct complex eigenvalue problem, if the model contains massless degrees

Known Error

CR 5708 of freedom, then the answers may be wrong. A possible symptom of this problem is the existence of spurious modes. Version 69.1 addresses this error by issuing the following message: SYSTEM WARNING MESSAGE 9093 (SOL10) THE FOLLOWING DEGREES OF FREEDOM HAVE NO MASS. USER INFORMATION: THIS CONDITION CAN PRODUCE EIGENVALUES AND EIGENVECTORS WHICH MAY BE DIFFERENT THAN THOSE CALCULATED IN A MODAL SOLUTION SEQUENCE; I.E., SOL 10. USER ACTION: AT THE MASSLESS DEGREES OF FREEDOM SPECIFY EITHER A SMALL AMOUNT OF MASS ON CMASS ENTRIES OR SPECIFY THE GRID AND COMPONENT ON OMIT_ ENTRIES. Avoidance: Manually omit the massless degre

Known Error

CR 5709

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Online Documentation - Design Sensitivity and Optimization - Incorrect Query Full Text Queries do not work in Chapter 7, "Example Problems," of the Design Sensitivity and Optimization User's Guide. If a query is made on a string in this document, the full text query tool may highlight spurious text.

Description Avoidance: If a user wants to search in this document, they need to go directly to the document, then issue a Search -> Text command (i.e., a local text search confined to this document only).

Known Error

CR 5720

Product

MSC / MD Nastran

Corrected Version 68.1 Abstract

Description

Nonlinear Slide Line Analysis - BLSEG, NLITER, TEMP(LOAD) - SFM 2085 If slideline contact with temperature loads is attempted the message "SYSTEM FATAL MESSAGE 2085, ELEMENT TYPE 116 NOT SUPPORTED FOR NONLINEAR ANALYSIS" is encountered in the NLITER module. Avoidance: There is no avoidance.

Known Error

CR 5723

Product

MSC / MD Nastran

Corrected Version 68.1 Abstract

Miscelleneous - SSALTERS, checka.v68 - UFM 73 If the checka.v68 dmap alter is used with Version 68.0.1 or newer versions of MSC/NASTRAN, then your job may fail with the following fatal message: USER FATAL MESSAGE 73: THE PARAMETER NAMED DESCYCL1 IS UNDEFINED.

Description

The checka.v68 dmap alter is written for Version 68.0.0 and you will not encounter this error if you are running Version 68.0.0. This error is due to the change in the DMAP in Version 68.0.1 to correct error 5435. Avoidance: Replace the following Call statement: CALL SEDRCVR, UG,QG,BGPDTS,EQEXINS,CSTMS,CASEDR,MPTS,DIT, ETT,OL1S,PJ1,ESTN,XYCDBDR,GEOM2S,GEOM3X,POSTCDB, ECTS,GPLS,EPTS,SILS,INDTA,KELM,KDICT,GPECT,VELEM, FORCE,XYCDB,PCDBDR,USET,SLT,UH1,OL1,DLT, FRL,SPSEL

Known Error

CR 5724

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Documentation - PCOMP, TEMPP3, TEMPP1 - Wrong Answers Models that specify nonzero ZO offsets on the PCOMP data entry in the presence of thermal gradient loads (TEMPP1 or TEMPP3) produce incorrect results.

Description Avoidance: When using thermal gradient loads and PCOMP structure, specify any nonzero ZOFF on the connection entry, (i.e., the CQUAD or CTRIA entry). Known Error

CR 5727

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Superelements - RANDOM, RANDPS, RANDTi - Missing Output

Description

If random analysis is performed (i.e., a RANDOM case control command references RANDPS and RANDTi bulk data entries) in a model containing superelements, then data recovery is not available for the upstream superelements. This

Known Error

CR 5727 is a Version 68+ error. Avoidance: Insert the following DMAP alter: COMPILE SEDRCVR SOUIN=MSCSOU NOLIST NOREF $ ALTER 194,194 $ dbview dynamic0=dynamics where (peid=0) $• DPD DYNAMIC0,GPLS,SILS,USET,,/ XGPL,XSIL,XUSET,,,PSDL,,,,,XEQDYN/ -1/DUM2/0/0/S,N,NOPSDL/0/0/ 0 / 1 /123/ DUM10 $

Known Error

CR 5728

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Miscellaneous - nastran script - SCO/UNIX Only, Data File Not Found MSC/NASTRAN Version 67.5 under SCO/UNIX 3.2 may fail with a message indicating the input data file is not found if the job is submitted with the .dat file extension. Avoidance : Submit the NASTRAN job without the .dat extension or modify the script as follows: At about line 190 of the nastran script:

Description

was: name=`basename ${jid} ${ext}` #jid_dir=`dirname ${jid}` nametmp=`basename ${jid}` if [ "$nametmp" = "$jid" ] ; then jid_dir="." else jid_dir=`echo ${jid} | sed "s;\/$name;;"` fi pid=${jid_dir}/${name}${ext} jid=${jid_dir}/${name}

change to: name=`basename ${jid} ${ext}` jid_dir=`dirname ${jid}` #nametmp=`basename ${jid}` #if [ "$nametmp" = "$jid" ] ; then # jid_dir="."

Known Error

CR 5728 #else # jid_dir=`echo ${jid} | sed "s;\/$name;;"` #fi pid=${jid_dir}/${name}${ext}

Known Error

CR 5733

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Composites - PSHELL, PCOMP - ZOFF Gives Wrong Answers

Description

Composite ply stress and strain data recovery is incorrect in nonlinear analysis solutions 66, 99, 106 and 129 when offsets are specified (i.e., ZOFFs on the CQUAD or CTRIA entries). Avoidance: No practical avoidance exists.

Known Error

CR 5736

Product

MSC / MD Nastran

Corrected Version 68.1 Abstract

Description

Matrix Methods - Sparse DECOMP, SYSTEM(69) - SFM 6137, Rank Deficient When SYSTEM(69), a.k.a. the DECOMP system cell, is set to 16 to place a 1.0 in the diagonal position for all null columns, sparse decomposition ignores this setting if spill occurs. If null columns exist, this error leads to SYSTEM FATAL MESSAGE 6137 indicating a RANK DEFICIENT matrix results. Note that SYSTEM(69) is set to 16 within some solution sequences. The solution sequences include cyclic symmetry. Avoidance: Increase memory to avoid spill, select standard decompositions by setting the SPARSE keyword to 1, or constrain the singular degrees of freedom.

Known Error

CR 5739

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

RFALTERS - RF31D81 - Missing GPSTRESS Output The entry point for rfalter rf31d81 is incorrect as it appears on the delivery tape, and therefore the GPSTRESS output is omited.

Description

Avoidance: Replace the following line in the RFALTER: alter 566 $ with

Known Error

CR 5739 alter 572 $

Known Error

CR 5754

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

Optimization/Design Sensitivity - DSAD - Insufficient Memory The DSAD module assumes that there is sufficient memory available for 7 * NCONSTR words of data where NCONSTR is the number of design constraints specified on DCONSTR entries. A test of this requirement is not made until after the data has been read in. If there is inadequate space, a machine dependent error is issued. Avoidance: Reduce the number of constraints or increase the available memory using the MEM request on the job submittal.

Known Error

CR 5758

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Cyclic Symmetry - MPCFORCE - Wrong Answers The MPCFORCE output in cyclic symmetry analysis is not calculated correctly.

Avoidance: Insert the following DMAP alter avoidance:

Description

COMPILE SEDISP, SOUIN=MSCSOU, NOLIST, NOREF $ $ $ CYCLIC SYMMETRY ALLOWS ONLY ONE BOUNDARY CONDITION. $ DO NOT PARTITION ACCORDING TO NUMBER OF LOADS AS IN REGULAR $ STATIC PROBLEM. IN CYCLIC, COLUMNS CORRESPOND TO SEGMENT OR $ HARMONIC RESPONSES, AS REQESTED BY USER. $ ALTER 133,133 $ PARTN PB,,ROW/,PM,,/1 $ ALTER 134 $ IF ( APP 'CYC' ) THEN $ ALTER 137 $ ELSE $ EQUIVX UGI/UGJ/ALWAYS $ ENDIF $

Known Error

CR 5758 ENDALTER $

Known Error

CR 5760

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Elements - CTETRA - UFM 4659

Description

If "USER FATAL MESSAGE 4659, DURING INTEGRATION FOR ELEMENT WITH ID = ***, BAD GEOMETRY HAS BEEN DETECTED." is encountered the user has the option to continue the run by setting SYSTEM(213)=1. This possible user action should be noted in the text of the message.

Known Error

CR 5763

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

DMAP - APPEND - UFM 5007 The APPEND module will not append two matrices of different TYPE together. If this is attempted, the module issues UFM 5007. Although this is clearly documented, the fact that the MATGEN and MATMOD modules output inconsistent matrix types may cause unsuspecting DMAPers to encounter this fatal message. Avoidance: Check the matrix trailers to verify that matrices going into APPEND are compatible.

Known Error

CR 5764

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

Optimization/Design Sensitivity - Multiple Boundary Conditions, GRAV - UFM 5423 If there are multiple boundary conditions and gravity and/or temperature loads in SOL 200, the run fails in the sensitivity analysis when it attempts to add the matrices EGM and EGKL. The message, "USER FATAL MESSAGE 5423---ATTEMPT TO ADD INCOMPATIBLE MATRICES" is output. Avoidance: Insert the following DMAP alter: COMPILE PSLGDV SOUIN=MSCSOU NOREF NOLIST

Known Error

CR 5764 ALTER 95,95 SSG1 SLT,BGPDTS,CSTMS,SILS,ESTDV2F,MPTX,ETTDV,EDT,, CASESX,DIT,,,,/AG ,PTELMDS,/LUSETS/0/1/'all' $ ALTER 100,100 SSG1 slt,bgpdts,cstms,sils,ESTDV2B,MPTXB,ettdv,edt,, casesx,dit,,,,/AGB ,PTELMDSB,/lusets/0/1/'all' $

Known Error

CR 5765

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Description

Documentation - Quick Reference Guide - Missing RF47D87 Table 6. in the Case Control Command section of the MSC/NASTRAN Quick Reference Guide indicates that STRAIN output for SOL 47 requires RF47D87. This RFAlter has never existed. Avoidance: Use SOL 114 to request STRAIN output in cyclic symmetry analysis.

Known Error

CR 5766

Product

MSC / MD Nastran

Corrected Version 68 Abstract

Description

Documentation - GPSDCON, ELSDCON - Not Supported in Cyclic The GPSDCON and ELSDCON documentation in the Version 68 Quick Reference Guide states that these Case Control requests are valid in 114. However, when these requests are specified in SOL 114, the following message is issued "SYSTEM WARNING MESSAGE 6245 (STDCON), ANALYSIS TYPE =CYC IS NOT SUPPORTED IN ERROR ANALYSIS. USER ACTION: USE STATIC ANALYSIS WITH STRESS REQUEST." This documentation error has been corrected in the 2nd release of the Version 68 Quick Reference Guide. Avoidance: There is no avoidance.

Known Error

CR 5776

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Optimization/Design Sensitivity - DVPREL2 - Wrong Answers

Known Error

Description

CR 5776 DVPREL2 entries that result in initial property values that are negative produce wrong answers in the optimizer. The problem can be observed by setting the IPRINT parameter to at least four and observing the constraint values inside the DOT optimizer. Avoidance: The only known avoidance is to replace the DVPREL2 entry with a DVPREL1 entry. This, of course, is only feasible when the relationship between the property value and the design variables is linear.

Known Error

CR 5777

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Optimization/Design Sensitivity - DOPR1, DESVAR, DLINK - SFM 3007, Poor Message When a DLINK entry references a non-existent DESVAR entry the following message is issued.

Description

SYSTEM FATAL MESSAGE 3007 MODULE = DOPR1 ILLEGAL INPUT TO SUBROUTINE DOPR1B FATAL ERROR Avoidance: Other than correcting the DLINK entry in error, there is no avoidance.

Known Error

CR 5778

Product

MSC / MD Nastran

Corrected Version 70 Abstract

DMAP - MESSAGE - UNRECOVERABLE Error If a MESSAGE DMAP statement contains two quote marks with no text between them (''), then the job fails on a CRAY computer with a message in the .log file stating:

Description

UNRECOVERABLE error on system request No such file or directory Avoidance: Always have at least one character between the quotation marks (even a blank character is acceptable).

Known Error

CR 5781

Product

MSC / MD Nastran

Corrected Version 68.1

Known Error

CR 5781

Abstract

script: - quelist - Script error if no quelist is supplied If the optional quelist is left off the "submit" line in the RC file as shown: submit=qsub -nc -q %que% -x -i -l -eo -s /bin/sh %job% then the job name to be executed in the que will have either an ampersand "&" (Version 68.0.2 and later system) or a "+" (Version 68.0.0 or Version 68.0.1) added to it. The improper jobname is echoed on the screen as follows:

Description

%nast68 ck1 que=large MSC/NASTRAN (Sun SunOS 4.1.2) Thu Oct 20 14:11:10 CDT 1994 MSC/NASTRAN job ck1 submitted on queue large qsub -nc -q largish -x -i -l -eo -s /bin/sh ./ck1.N13745.06+ This error only occurs when the quelist is left off the submit definition as would be used when the same submit command is to apply to all que options.

Avoidance: Change the following line in the nast68/emas3 script (about 2 Known Error

CR 5786

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

Eigenvalue Analysis - EIGRL, SYSTEM(194) - Wrong Answers The Lanczos eigenvalue extraction method may produce incorrect results when the "High Performance Option" Number of frequency spectrum subsegments SYSTEM(197) is set to greater or equal to 2. Avoidance: Do not use the "High Performance Option" SYSTEM(197).

Known Error

CR 5787

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Documentation - MSC/NASTRAN Thermal Analysis User' Guide - Incorrect Index

Description

The index of the MSC/NASTRAN Thermal Analysis User's Guide is misaligned.

Known Error

CR 5787 The index of the Version 69 online documentation on the Thermal Analysis User's Guide is correct.

Known Error

CR 5788

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Grid Point Force - GPFORCE, PARAM,NOGPF,-1 - Extra Output PARAM,NOGPF,-1 does not suppress the GPFORCE output for statics and modes.

Description

Avoidance : Either remove the GPFORCE request from the case control or apply the following alter:

COMPILE SEDRCVR SOUIN=MSCSOU NOLIST NOREF ALTER 268,268 $ v68 remove printing of gpforce Known Error

CR 5789

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Heat Transfer - CHBDYi, CONV - UFM 311 Multiple convection boundary conditions on a single CHBDYi surface are not allowed in MSC/NASTRAN Version 68. If attempted the message: USER FATAL MESSAGE 311 (IFPDRV) NON-UNIQUE FIELD 2 ON BULK DATA CARD CONV 60 SORTED CARD COUNT = 14 DMAP FATAL MESSAGE 9002 (IFPL) - ERROR ENCOUNTERED IN MODULE IFP . SEE MESSAGES ABOVE IN THE BULK DATA ECHO. Avoidance: Define multiple CHBDYi elements.

Description For example: CHBDYE,60,1,6 CONV,60,35,1,,99 CONV,60,35,1,,99 is not allowed whereas CHBDYE,60,1,6 CHBDYE,70,1,6 CONV,60,35,1,,99

Known Error

CR 5789 CONV,70,35,1,,99 is allowed. Avoidance: Define another CHBDY card and apply second set of convection boundary condition on that card.

Known Error

CR 5797

Product

MSC / MD Nastran

Corrected Version Abstract

Documentation - Coupled Fluid Structure Interaction, Ref Manual. The equations describing the structural modal participation factors and the load modal participation factors for a coupled fluid-structure interaction problem listed on page 15.4.2-6 of the MSC/NASTRAN Reference Manual, V68 are in error. Z2=[-w^2 Mf + i w Bf + K ]^(-1) modal impedence

Description structure participation = -w^2 [PHIf] [Z2] [a]^T [XIs] where [a] is the modal coupling matrix and [XIs] is diagonal load participation = [PHIf][Z2]{Qf} where {Qf} is fluid modal load panel participation = -w^2 [PHIf][Z2][PHIf]^T [Ab]^T [PHIs][XIs] where [XIs] is diagonal Known Error

CR 5798

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Acoustic Analysis - PANEL - Wrong Answers for Panel Participation Factor If more than one PANEL is defined, panel modal participation results are wrong. The results are the same for all the panels. Avoidance:

Description

Either run the analysis for one panel at a time or use the following Version 68 alter: compile mpf souin=mscsou alter 1 type db abeh $

Known Error

CR 5802

Product

MSC / MD Nastran

Corrected Version GL Abstract

Material Nonlinear Analysis - TEMP(LOAD) - Superelements vs. NonSuperelements If superelements are used in a nonlinear run with temperature dependent material properties, the superelement properties are calculated using the TEMP(INIT), rather than the TEMP(LOAD). This is a limitation since superelements are linear, their material properties are not changed during the analysis. This can lead to different answers when comparing superelement models to non-superelement models.

Description Avoidance: In order to use the TEMP(LOAD) for the material properties, use the following DMAP alter in Version 68: COMPILE SELG, SOUIN=MSCSOU, NOLIST, NOREF ALTER 11,11 SSG1 SLT,BGPDTS,CSTMS,SILS,EST,MPTS,ETT,EDT,MJJ,CASESX, DIT,,,,/PJX,PTELEM,/LUSETS/1//'NLST' $ Known Error

CR 5803

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Miscellaneous - GINO - SYSTEM FATAL ERROR (bio_c.read) UNIX versions of MSC/NASTRAN Version 68 and MSC/EMAS Version 3 may report a SYSTEM FATAL ERROR (bio_c.read) in the LOG file but will complete the job normally. Avoidance: No avoidance is necessary, the error message can be ignored.

Known Error

CR 5804

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Miscellaneous - RC File - NASTRAN OLDQ4K, NSINIT ERROR 20, UFM 17 "NSINIT ERROR 20 *** SYNTAX ERROR IN CONTROL FILE"or "UFM 17 UNIDENTIFIED NASTRAN CARD KEYWORD" occurs if NASTRAN OLDQ4K is placed in a runtime configuration file or the data deck. Refer to section 3.4 of the MSC/NASTRAN Version 68 Installation and Operation Instructions for information on the location and format of the runtime configuration files.

Known Error

CR 5804 Avoidance: Two avoidances exist. Either OLDQ4K can not be the first system cell on the NASTRAN command line or the equivalent system cell, SYSTEM(173), must be used in place of the keyword.

Known Error

CR 5805

Product

MSC / MD Nastran

Corrected Version 2001.0.9 Abstract

Nonlinear Transient Analysis - NLTRD, RESTART - SFM 4276 EC 1044, UIM 4550 IF a model containing superelements is executed in solution 106, and then restarted into solution 129 (using PARAM, SLOOPID), and the "METHOD" field on the TSTEPNL entry is set to AUTO, then the job fails and the following fatal message is issued:

Description

SYSTEM FATAL MESSAGE 4276 ERROR CODE 1044 (BIOMSG: ERROR 1044 HAS OCCURRED IN ROUTINE OPEN FILE INDEX (FILEX) = 0) Immediately preceeding this fatal message, USER INFORMATION MESSAGE 4550, NEW STIFFNESS MATRIX REQUIRED is issued. This error may happen even though the nonlinear iteration module output indicates that all time-steps have been successfully completed. Avoidance: Use the default ADAPT method.

Known Error

CR 5807

Product

MSC / MD Nastran

Corrected Version 70 Abstract

DMAP - COMPILE - UFM 423 If a user attempts to compile a user dmap where the name of the dmap begins with the letter "E", the job may fail with the message "USER FATAL MESSAGE 423 (ATTDBS) THE FOLLOWING PHYSICAL FILE DOES NOT EXIST /msc/msc68/emas3/sunos/del/ESS.MASTERA".

Description Avoidance: Change the main dmap and SOL name so that it does not begin with "E". This apparent error is the result of an MSC/NASTRAN feature that will run MSC/EMAS if a deck with a 'SOL 300' or 'SOL E*' entry is submitted. If such a SOL entry is found, the script attempts to attach the MSC/EMAS Solution Sequences. This delivery database does not exist in a pure

Known Error

CR 5807 MSC/NASTRAN installation.

Known Error

CR 5808

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

Differential Stiffness and Buckling - EIGRL, EIGB - Wrong Answers or UFM 4683 If the a-set and g-set are the same (no SPCs, MPCs, or reduction) in any superelement or the residual structure, then the differential stiffness matix used in solution 105 (buckling) or the buckling option in solution 200 will not be correct. The error may lead to wrong answers or "USER FATAL MESSAGE 4683, DIFF. STIFFNESS MATRIX NEEDED FOR EIGENVALUE ANALYSIS". DMAP avoidance: COMPILE SEKDR, SOUIN=MSCSOU, NOLIST, NOREF $ ALTER 42, 42 $ EQUIVX KDGGX/KDAA/-1 $

Known Error

CR 5819

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Static Analysis - TEMP(LOAD), LSEQ - UFM 9058 If the LOADSET, LSEQ combination and TEMP(LOAD) are specified in MSC/NASTRAN Version 68, then "USER FATAL MESSAGE 9058" may be issued in SOL 101. This error occurs when there are unreferenced LSEQ entries.

Description

Avoidance: Remove the unreferenced LSEQ entries or insert the following alter: compile sestatic souin=mscsou noref nolist alter 59 $ PARAML CASEsx//'DTI'/nskip/7//S,N,TEMPLD $

Known Error

CR 5820

Product

MSC / MD Nastran

Corrected Version 68.2

Known Error

CR 5820

Abstract

Optimization/Design Sensitivity - ANALYSIS=SAERO - Wrong Answers Applied loads, for example to simulate subcase dependent fuel loads, are ignored and wrong answers are produced if a static aeroelastic design task is submitted in solution 200.

Description

Avoidance: Insert the following DMAP avoidance: compile phase1dr souin=mscsou nolist noref alter 81,81 alter 89 equivx casesx/casew/-1 $

Known Error

CR 5823

Product

MSC / MD Nastran

Corrected Version 68.1 Abstract

Inertia Relief - Multiple Subcases, SUPORT1 entries - Wrong SPC forces If inertia relief is used in conjunction with multiple subcases each referencing a different set of SUPORT DOFs, then the spcforces will be incorrect. This is a Version 68 error since prior versions do not support multiple inertia relief sets. This feature is activated with the use of the SUPORT1 entries. Avoidance: Insert the following DMAP alter avoidance.

Description

compile sestatic souin=mscsou nolist noref alter 100,100 $ CALL SUPER3 CASECC, ,UL, , , , , , , , CRX, , ,,,, PCDB,XYCDB,POSTCDB,FORCE,EMAP,MAPS,EQEXINS, PVTS,CASES,SLT,ETT,GOAT,,LOO,CRJ,LAO,UOO,UOX,GPLS,USET, SILS,PJ,EDT,YS,GM,PSS,KFS,KSS,QR,,,,,, DYNAMICS,BGPDTS,CSTMS,MPTS,DIT,EST,GEOM2S,GEOM3S,ECTS, EPTS,INDTA,KE

Known Error

CR 5829

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Plotting - SEUPPLOT - Missing Plot Output In SOL 103, if the SEUPPLOT command is used to generate assembly plots, plots will be available for only the first half of the modes in the solution.

Description Avoidance: Apply the following DMAP avoidance in Version 68:

Known Error

CR 5829 compile semodes, souin=mscsou, nolist, noref alter 1 $ disable scratch LTU logic - otherwise the datablocks will $ not be there when needed for plotting putsys(0,192) $ compile sedrcvr, souin=mscsou, list, noref alter 1 type db,phidlg $unused datablocks in SOL 103 $ alter 48 $ after sdr2 copy ug/ugcopy $ append ug,ugcopy/ugtwice $ get "double" set of solutions $ SDR2 to get "double plot vectors" message //'seid='/seid $ SDR2 CASEDR,CSTMS,MPTS,DIT,EQEXINS,,ETT,OL2,BGPDP, PJ1,QG,UGtwice,EST ,XYCDBDR,OINT,PELSETS,VIEWTB/ ,,OUGVxxx,,

Known Error

CR 5831

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

DMAP - MATMOD, FBS, TRNSP - Wrong Answers, SFM There is a special form of an identity matrix called a form 8. Conventional identity matrices are form 6. This type of matrix can be generated with MATMOD option 2, or may be generated internally in modules. The new sparse options may have trouble with this form of matrix. Troubles observed to date include:

Description

Wrong answers from FBS when more than one pass is required. The symptoms for the FBS problem found to date include a solution which has about 50% more non-zero terms than it should. A SYSTEM FATAL MESSAGE in the TRNSP module. Avoidance: The error in FBS may be avoided by switching back to the non sparse methods by setting SYSTEM(126)=1. It is recommended this be done only locally around the offending module with PUTSYS statements. The error in TRNSP may only be avoi

Known Error

CR 5838

Product

MSC / MD Nastran

Known Error

CR 5838

Corrected Version 69 Abstract

Description

Loads - TEMP(LOAD) - UWM 4012, UFM 4017 When doing a static analysis with temperature loads in Version 68, it is necessary to specify the temperature for all grid points in the model. If this is not done, the following messages will be issued, "USER WARNING MESSAGE 4012, THERE IS NO ELEMENT, GRID POINT, OR DEFAULT TEMPERATURE DATA FOR TEMPERATURE SET 102, WITH RESPECT TO ELEMENT ID = 0","USER FATAL MESSAGE 4017. THERE IS NO TEMPERATURE DATA FOR ELEMENT 15 IN SET 2". Unfortunately, the element ID and set numbers are incorrect. Avoidance: Always include a TEMPD bulk data entry in any static analysis with temperature loads.

Known Error

CR 5839

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Heat Transfer - heatconv, SPC - Cannot Convert Large Field Format, Wrong Answers The heatconv program does not correctly handle all large field SPC entries. In particular, given the following large format SPC entry: SPC* 1 1 1 2.00000000E+01 heatconv will incorrectly copy this to a small format entry as follows:

Description

SPC 1 1 1 2.000000 Whenever the temperature fields, i.e., fields 5 & 8, exceed eight characters in length, incorrect results will occur.

Known Error

CR 5841

Product

MSC / MD Nastran

Corrected Version 2001.0.1 Abstract

Composites - PCOMP, MAT2 - UFM 4291

Description

Certain MAT2 entries that are referenced from a PCOMP are not checked for correctness. In particular, if 13 and/or 23 terms are non-zero and the 33 term is zero, the matrix is not positive definite. In this case MSC/NASTRAN

Known Error

CR 5841 will create potentially incorrect PSHELL/MAT2 combinations from the PCOMP/MAT2 inputs. Avoidance: Enter a positive definite MAT2 entry.

Known Error

CR 5843

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

P-Elements - RFORCE - Wrong Answers or SFM 4276 Although it is not documented, RFORCEs are not implemented for pelements. If RFORCES are applied to p-elements either wrong answers or a SYSTEM FATAL MESSAGE 4276 results. Avoidance: Do not apply RFORCEs to p-elements.

Known Error

CR 5844

Product

MSC / MD Nastran

Corrected Version 69 Abstract

P-Elements - HEX20, PENTA15, TETRA10 - Missing Documentation The CHEXA element with 20 grids, the CPENTA element with 15 grids, and the CTETRA element with 10 grids may not be used as p-elements by referencing the PVAL entry. If attempted, the following message is issued:

Description *** USER FATAL MESSAGE 6390, (GP0A), ELEMENT ID = 1 TYPE HEXA20 OR PENTA15 AND/OR TETRA10 ARE NOT SUPPORTED IN P-ELEMENT ANALYSIS. USER ACTION: CHECK ELEMENT CONNECTION ENTRY OR SET ENTRY. Known Error

CR 5848

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

Optimization/Design Sensitivity - DSCREEN - Poor Convergence The DSCREEN entry permits the user to override default screening parameters for design optimization. This capability does not work for responses TDISP,TVELO,TACCL,TSPC,TSTRE,TFORC,TRIM,STABDER and FLUTTER. Avoidance: The only avoidance is to do a TABEDIT on the DSCREN datablock.

Known Error

CR 5848 The following words correspond to the data locations for the responses TRS NSTR TDISP 179 180 TVELO 182 183 TACCL 185 186 TSPC 188 189 TSTRE 191 192 TFORC 194 195 TRIM 245 246 STABDER 248 249 FLUTTER 251 252 A candidate DMAP for performing the TABEDIT is: compile desopt souin=mscsou nolist noref alter 41 $ call dbstore dti,dtindx,,,//1/

Known Error

CR 5849

Product

MSC / MD Nastran

Corrected Version 68.1 Abstract

Description

Matrix Methods - FBS - UWM 4398, Wrong Answers MSC/NASTRAN Version 67.7 and 68 on the CRAY C90 computer may produce wrong answers for models where FBS method 2 is selected. The error may be evidenced by "USER WARNING MESSAGE 4398" which indicates "DEGREES OF FREEDOM DO NOT PASS SYMMETRY CHECK". The error only occurs when there are strings in the factor that are longer than 64 terms. Note that except in superelement models, that FBS method 2 is rarely selected. Avoidance: FBS Method 2 should be deselected by setting "FBSOPT=-1" in the system RC file on Version 67.7 and 68 CRAY C90 computers.

Known Error

CR 5850

Product

MSC / MD Nastran

Corrected Version 68.1 Abstract

Miscellaneous - IFP, XRCARD - Infinite CPU Loop, Overflow Input Buffer

Description

Some invalid bulk data input may result in an infinite cpu loop in the routine XRCARD. Although the exact type of input that results in this error is not known, the specifics of the input line that resulted in this error is

Known Error

CR 5850 that the line was over 80 characters, contained many leading blanks and included an embedded negative, "-", sign. The infinite cpu loop has only been reproduced on the CRAY computer but may occur on other systems. Avoidance: There is no practical avoidance.

Known Error

CR 5852

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - DMAP Module Dictionary, MODTRL - Bad Input Matrix If the MODTRL module is used to increase the number of columns in a matrix, the resulting matrix is unusable in most modules, including matprn and ADD. The cause of the error is that the matrix does not have column headers for the added null columns.

Description

Avoidance: The MATGEN and ADD module should be used to increase the number of columns in a matrix. An example follows: matgen ,/nullab/7/rn/cn $ null matrix with rn rows and cn cols. user must set rn and cn above. add nullab,oldmat/newmat $ trailer will match first input equivx newmat/oldmat $ oldmat is now 'bigger'

Known Error

CR 5858

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

Optimization/Design Sensitivity - SPCFORCE and MPCFORCE - Wrong Answers If scr=yes is used in SOL 200 with dynamic optimization or sensitivity, then MPCFORCE and SPCFORCE output does not include mass and damping effects after the first design cycle. (Version 68 only) Avoidance: Specify scr=no. An extensive DMAP alter is also available if scr=yes is desired.

Known Error

CR 5860

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Aeroelastic Analysis - GI, CAERO1, CAERO2 - Wrong Answers

Description

MSC/NASTRAN Version 68 on Sun computers may produce wrong answers

Known Error

CR 5860 for aeroelastic flutter problems when aerodynamic bodies, i.e. CAERO1 or CAERO2 elements, are present. Avoidance: There is no avoidance.

Known Error

CR 5861

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Dynamics - PARAM,MODACC - Poor Displacement Results The mode acceleration method is intended to improve element stress data recovery in dynamic solutions using modal formulations. However an error may occur in the total displacements when free-body motions are present. This error will NOT affect strains, stresses or constraint forces. The major problem is that the angular displacements or pointing directions will be affected. The problem occurs because the "improved" relative displacements are not orthogonal to the free-body modes and create small additional displacements and rotations. The error is proportional to the local frexibility of the SUPORT degrees of freedom. This error is considered fixed in Version 69 by the addition of a new mode acceleration option which is selected by setting PARAM,MODACC,1 instead of PARAM,MODACC,0. Th

Known Error

CR 5862

Product

MSC / MD Nastran

Corrected Version Abstract

Description

Database - DBUNLOAD - UFM 3007, illegal input to subroutine PVT If the dbunload is done on a long word machine such as Cray and dbload is attemted on a short word machine, then UFM 3007, illegal input to subroutine PVT may be issued. This error occurs only if the initial run which created the databases had parameter specifications in the Case Control. This occurs since the diliminator for the parameter in the Case Control is machine dependent.

Avoidance: There are two avoidances:

Known Error

CR 5862 1. Remove the parameter specifications from the initial run which creates the databases. or. 2. Use the following alter in the dbload run. ACQUIRE NDDL ASSIGN DBLOAD='neutrala.cray',FORM=FORMATTED DBLOAD FORMAT=NEUTRAL $ $ avoidance is to add the follo

Known Error

CR 5863

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

P-Elements - GP4 - UFM 4276, CSTM DOES NOT EXIST (GP4)

Description

If a model contains p-elements and there is insufficient memory in the GP4 module the message "USER FATAL MESSAGE 4276, CSTM DOES NOT EXIST (GP4) may be output.

Avoidence: Request more memory and rerun the job. Known Error

CR 5864

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

Aeroelastic Analysis - DIAG 50 - Unsplined Rigid Stability Derivatives For Version 68, static aeroelastic analyses (SOLs 144 and/or 200) produce Unsplined Rigid Stability Derivatives. These data are presented only to provide a check of the splining and are not used in the solution. For antisymmetric models and models with no symmetry (SYMXZ = -1 or 0), the numbers may be in error. For sideforces the error is likely to be simply one of sign. For yawing and rolling moments, the error is less obvious.

Known Error

CR 5866

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Heat Transfer - RADMTX - Duplicate Continuation Entry with Multiple

Known Error

CR 5866 Cavities

Description

For the multiple cavity radiation view factor calculation, each cavity will have a RADLST and RADMTX entry associated with it. The punch file which contains the MSC/NASTRAN calculated RADMTX entries for each cavity contains duplicate RADMTX continuation identifiers. Thus, subsequent restarts using the punch file fail. Avoidance: Since continuation identifiers are not necessary if the input is in sequential order, blank out all the continuation identifiers in field 10 and field 1 of the RADMTX entries.

Known Error

CR 5867

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

Mulitpoint Constraints - SPLINE2 - Singular Matrix, Wrong Answers The Quick Reference Guide indicates that the DTOR value input on the SPLINE2 entry must be greater than 0.0. However, this requirement is never checked. If the user leaves DTOR field blank the run could give wrong answers or fail due to a singular spline matrix. Avoidance: Specify a value greater than 0.0 for DTOR.

Known Error

CR 5868

Product

MSC / MD Nastran

Corrected Version 68.1 Abstract

Installation - Authorization - UFM 3060, BUCKLING not in Approved List An authorization code for the workstation option is suppose to include statics, normal modes and buckling. An error in the authorization code generator resulted in workstation options not including buckling.

Description Avoidance: The error in the authorization code generator has been corrected. Contact MSC for a new code. Known Error

CR 5871

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Restarts - RESTART PROJECT - Inefficient Restart

Description

In Version 68, the PROJECT keyword is ignored on the RESTART statement

Known Error

CR 5871 which will result in an inefficient restart. For example, 1. The initial run creates project A: PROJECT='A' ASSIGN MASTER='A.MASTER', DELETE 2. The subsequent run restarts from project A into project B: PROJ='B' ASSIGN MASTER='A.MASTER' RESTART PROJECT='A',KEEP Avoidance: For SOLs 101 through 200 insert the following DMAP alter: compile ifpl souin=mscsou noref nolist alter 80,80 type parm,,i,,projid=1,versid=1 $ projid=1 $ set the projid to the integer equivalent of the project you are restarting from. versid=1 $ set the versid to the version you are restarting from $ dbdict datablk=geom1q $ alter 118,131 DBVIEW GEOM1R=GEOM1Q(WHERE version=versid and PROJECT=PROJID) $ DBVIEW

Known Error

CR 5876

Product

MSC / MD Nastran

Corrected Version 69 Abstract

File Management Section - EXPAND, RESTART - SFM 4276 XIO, EXPAND, SCR300 An attempt to expand a database fails when restart is attempted in the same run. A sample File Management Section demonstrating the error follows: assign dbup1a='scr7a.dbup1a' expand dbup1, logical=(dbup1a(100)) restart version=1 keep

Description

The sample input leads to the following fatal message due to the scr300 file being improperly defined: "SYSTEM FATAL MESSAGE 1030 (XIO) BLOCK NUMBER MISMATCH IN READ SYSTEM FATAL ERROR 4276.XIO ERROR CODE 4276"

Known Error

CR 5876 Avoidance: 1) run an "expand" job only (i.e. expand and endjob) 2) run the restart job

Known Error

CR 5877

Product

MSC / MD Nastran

Corrected Version 67.5.0.1 Abstract

Miscellaneous - SCO/UNIX - UFM 3060

Description

The SCO/UNIX Version 67.5 of MSC/NASTRAN may issue "USER FATAL MESSAGE 3060" indicating authorization code violation during long running job with many module changes (e.g. nonlinear). Avoidance: There is no avoidance. This problem will be fixed on a rerelease version (MSC/NASTRAN v67.5.0.1 for SCO/UNIX).

Known Error

CR 5880

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

P-Elements - TEMP - UFM 4017 All p-version models which contain thermal loads via TEMP entries and more than one type of solid element (HEXA, PENTA, TETRA), fail with the following fatal message, "USER FATAL MESSAGE 4017. THERE IS NO TEMPERATURE DATA FOR ELEMENT y IN SET x".

Description Avoidance: If the thermal loading is a uniform temperature increase throughout the entire structure, use a TEMPD Entry. Otherwise, the user must use an equivalent TEMPF Entry. Also, it may be possible to use only one element type in the model. Known Error

CR 5881

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Documentation - PARAM,BAILOUT - Missing Documentation

Description

MSC/NASTRAN Version 68 supports multiple boundary conditions in the structured solution sequences. However, PARAM BAILOUT cannot be changed between subcases.

Known Error

CR 5889

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Optimization/Design Sensitivity - DRESP2 - Wrong Answers

Description

If a DRESP2 entry refers to two or more DRESP1 entries and there are DVPREL2 entries in the input file, then the sensitivities printed in the columns of the DSCM2 matrix associated with the DRESP2 entry are in error. Avoidance: There is no avoidance other than to recast the problem so that it does not require the offending DRESP2,DRESP1,DVPREL2 combination.

Known Error

CR 5891

Product

MSC / MD Nastran

Corrected Version 70.5.1 Abstract

Elements - PENTA - Possible Wrong Answers, UFM 4654

Description

If a pyramid-shaped degenerate PENTA element is input to MSC/NASTRAN, USER FATAL MESSAGE 4654 is issued warning of two corner points with the same coordinates but the run will continue. Pyramid-shaped PENTA elements are not supported and should not be used.

Known Error

CR 5893

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Sequencer - SEQP, PARAM,NEWSEQ,6 PARAM,OLDSEQ,6 - SFM 4276, EC 3002 It is possible that jobs that request param,newseq,6 prior to Version 69 or param,oldseq,6 in Version 69 and after may encounter SYSTEM FATAL MESSAGE 4276, ERROR CODE 3002 in the SEQP module.

Description

By default sequencing in the SEQP module was turned off in Version 69 and beyond. PARAM,NEWSEQ was changed to PARAM,OLDSEQ to force the user to go out of his way to request sequencing. Thus, this error is considered corrected in Version 69 by the fact that sequencing is no longer recommended.

Known Error

CR 5900

Product

MSC / MD Nastran

Corrected Version GL Abstract

Material Nonlinear Analysis - RESTART, NLPARM - DIM 9005, UFM 2044, SFM

Known Error

CR 5900 3007

Description

If thermal loads are applied in a SOL 106 cold start, and, if in the restart, PARAM,LOOPID is not the last loop id for the subcase prior to PARAM, SUBID then the program will issue various misleading fatal messages. In one example the message "USER FATAL MESSAGE 2044 UNDEFINED TEMPERATURE SET, SYSTEM FATAL MESSAGE 3007 MODULE=NLCOMB ILLEGAL INPUT TO SUBROUTINE NLCPTM" was encountered. Avoidance: Other than specifying the correct LOOPID, there is no avoidance.

Known Error

CR 5911

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Complex Eigenvalue Analysis - SPCForces - Wrong answers In MSC/NASTRAN Version 68, the SPCForce results are incorrect in SOLs 107, 110, and 145 only. The SPCForces do not include the effects of the imaginary part of the eigenvalue which results in "undamped" SPCforces. Avoidance: Insert the following DMAP alter.

Description

COMPILE CFORCE SOUIN=MSCSOU noLIST NOREF $ ALTER 47,47 $ replace DSAP PARAML OL//'TRAILER'/1/S,N,NFREQS $ NUMBER OF Eigenvalues TYPE PARM,,I,N,II=0,iip3,iip4 $ LOOP COUNTER TYPE PARM,,CS,N,IOMEGAX,MOMEGX $ FILE qx1=APPEND $ DO WHILE (II II = II + 1 iip3=6*(ii-1)+3 $ clama word 3 iip4=6*(ii-1)+4 $ clama word 4 PARAML OL//'DTI'/2/IIP3/S,N,omega $ real eigenvalue PARAML OL//'DTI'/2/IIP4/S,N,omegai $ imag eigenvalue IOMEGAX = CMPLX(omega,OMEGAi) $ MOMEGX = IOMEGAX**2 $ MATMOD KUx,,,,,/K

Known Error

CR 5914

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Nonlinear Transient Analysis - PARAM,G, PARAM,W3 - Incorrect Structural Damping

Description

In MSC/NASTRAN Version 68, solution 129, the structural damping for linear

Known Error

CR 5914 elements specified by parameters G and W3 is doubled. The structural damping specified by GE and parameter W4 are correct. (V68 only) Avoidance: Apply the following DMAP alter: compile nltran, souin=mscsou, nolist, noref $ alter 224, 224 $ ADD5 BDD0,KDDNL,K4DDNL,,/BRDD//GW3/RW4 $ endalter $

Known Error

CR 5915

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Case Control - GPSDCON, ELSDCON - Missing Output

Description

Element and grid point stress discontinuity output (ELSDCON and GPSDCON Case Control commands) cannot be requested for a single subcase or a set of subcases. This output is only generated if the request is made for all subcases in Case Control. Avoidance: The user must place these commands above the subcase level or in each subcase.

Known Error

CR 5918

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Complex Eigenvalue Analysis - CEAD - Poor Message, UFM 4215 When running a complex eigenvalue analysis, the message "USER FATAL ERROR 4215. COLUMN 1 OF DATA BLOCK SCRATCH IS NULL BUT ROW 1 IS NOT" may be issued. However, this null column does not affect the solution. Avoidance: There is no avoidance.

Known Error

CR 5920

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Transient Heat Transfer - MATT4,TABLEM4 - SFM 2090

Description

Contrary to the documentation , the temperature dependent specific heat, T(CP), on the MATT4 entry, cannot be specified with the TABLEM4 entry (coefficient of a power series). If this definition is attempted, the message "SYSTEM

Known Error

CR 5920 FATAL MESSAGE 2090, TABLE DICTIONARY ENTRY 201 MISSING" is output. Avoidance: Use the TABLEM1, TABLEM2 or TABLEM3 entry to specify temperature dependent specific heat.

Known Error

CR 5922

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Miscellaneous - ALPHA OSF/1 Only - UFM 1012 DBSET DBALL IS FULL On the ALPHA OSF/1 release of MSC/NASTRAN when the system runs out of allocated disk space the job may hang. When the process is killed, the system sends the message that the job is finished and the output files look as they should with no indication of a problem. This error has also been observed in connection with SFM 4393 followed by SFM 4276 Error Code 3002. Avoidance: Other than killing the job, there is no avoidance.

Known Error

CR 5924

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

Nonlinear Transient Heat Transfer - TEMPBC - SFM 4276 EC 3021 If a TEMPBC entry of TYPE="STAT" and TYPE="TRAN" is referenced in the same nonlinear transient run, then the job fails and the message "SYSTEM FATAL ERROR 4276.WRITE ERROR CODE 3021", is issued. Avoidance: Use SPC's to fix the constant temperature boundary condition. Use TEMPBC TYPE="TRAN" to designate the time-varying boundary condition.

Known Error

CR 5927

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Matrix Methods - MCE1, RBEi, MPC - UWM 6137, INPUT MATRIX IS RANK DEFICIENT

Description

Although it is not illegal to specify a DOF as independent on one rigid element and dependent on another rigid element, if the definitions form a "closed loop" such that DOF A is dependent on DOF B and DOF B is either directly or indirectly dependent on DOF A, and sparse decomposition is selected

Known Error

CR 5927 the message, "USER WARNING MESSAGE 6137, INPUT MATRIX IS RANK DEFICIENT" is output. Avoidance: This error is corrected in Version 67 and later systems for standard decomposition. Thus, if the user forces standard decomposition by setting the SPARSE keyword to 1, then USER FATAL MESSAGE 6202 is produced which identifies the rigid elements in error.

Known Error

CR 5930

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

Transient Heat Transfer - MATT4, RADMT - UWM 2013 In a transient thermal analysis (SOL 159), if QVECT load is used in conjunction with temperature dependent absorptivity. This input leads to the message "USER WARNING MESSAGE 2013, NO STRUCTURAL ELEMENTS EXIST. FATAL ERROR" being issued. The QVECT load is directional load such as solar load. Avoidance: Defines a constant absorptivity value instead of temperature dependent absorptivity value.

Known Error

CR 5933

Product

MSC / MD Nastran

Corrected Version GL Abstract

DMAP - DCMP, DECOMP - Wrong (Zero) Results The DECOMP and DCMP modules have an optional set of parameters which should give the scaled determinant (DET) and the scale factor (POWER) of the input matrix. For the sparse methods, they are set to zero.

Description

Avoidance: An avoidance is to select the nonsparse decomposition methods when a determinant is needed. That is set system cell 126 to 1 (a.k.a. NASTRAN SPARSE keyword) for symmetric matrices and system cell 209 equal to 0 (a.k.a. NASTRAN USPARSE keyword) for unsymmetric matrices.

Known Error

CR 5934

Known Error

CR 5934

Product

MSC / MD Nastran

Corrected Version 68.1 Abstract

Documentation - GMBC - UFM 315 The following message is issued when the LID field of the GMBC entry is 0 and it contains a continuation entry, i.e., ENTITY = FEFACE and METHOD = LINEAR. USER FATAL MESSAGE 315 (IFPDRV) FORMAT ERROR ON BULK DATA ENTRY GMBC 0 SORTED CARD COUNT = **

Description Remark 4 under the Version 68 Quick Reference Guide's description of the GMBC entry should be updated to include this condition and it should be stated that not only is the METHOD field not required but will result in a USER FATAL MESSAGE if included. This error is essentially the same as error 5506, it has been corrected in the 2nd printing of the Quick Reference Guide. Known Error

CR 5935

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Miscellaneous - ADD5 - SFM 4276, EC 70020 An error in the bufferpool logic may result in "SYSTEM FATAL ERROR 4276.BPREAD ERROR CODE 70020" to be issued from the ADD5 module. This error is very much problem and buffersize dependent.

Description

Avoidance: Changing the buffersize may avoid the error but the sure avoidance is to turn off bufferpooling prior to the ADD5 module by setting SYSTEM(119) as follows: ALTER xxx $ turn off buffpool just before ADD5 putsys (2,119) ALTER yyy $ turn buffpool back on just after ADD5 putsys (3,119)

Known Error

CR 5941

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Optimization/Design Sensitivity - DOPTPRM - Missing Output

Known Error

CR 5941 If the P1 parameter on the DOPTPRM bulk data entry is either set to the default value of 0 or simply not specified and allowed to become the default value of 0, and the P2 field is specifed, then requested data on the P2 field is not printed for the last design cycle. Avoidance: Set parameter P1 to 1 to obtain the output for the last design cycle or apply the following dmap alter:

Description

$ $ This alter will print the design optimization output $ for the last design cycle regardless of what the value $ of the 'p1' parameter in the doptprm entry is set to. $ ksh: cray.err: permission denied $ **** THIS ALTER IS FOR VERSION 68.2 ONLY **** $ compile desopt nolist noref souin=mscsou alter 'CALL PREDOM' $ dummy matgen calls to satisfy dmap complier file cntabrgp=save,ovrwr

Known Error

CR 5946

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

Optimization/Design Sensitivity - DRESP1 - Uses Von Mises Only Remark 1 for the DRESP1 entry indicates that, for stress/strain item codes that have dual meanings, the selection is made based on the option specified in case control. This pertains to Von Mises and Max Shear selection. Due to a programming error, the remark is incorrect and Von Mises results will be selected, regardless of the case control request, as it was in Version 67. Avoidance: Users desiring to use Max Shear in a design task will have to synthesize it from basic stress results.

Known Error

CR 5948

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Documentation - QRG, USET, PARTN - SFM 3007

Description

If a USETi bulk data entry lists a standard MSC/NASTRAN set, such as S or M, the program may fail in the PARTN module with the message "SYSTEM FATAL

Known Error

CR 5948 MESSAGE 3007, ILLEGAL INPUT TO SUBROUTINE". Avoidance: This entry should only reference new sets defined on DEFUSET bulk data entries.

Known Error

CR 5953

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Optimization/Design Sensitivity - DCONADD,DCONSTR - UFM 316 If the DCONADD entry references only a single DCONSTR entry on any continuation entry, then the job fails and the following message is issued: USER FATAL MESSAGE 316 (IFPDRV) ILLEGAL DATA ON BULK DATA CARD DCONADD xx SORTED CARD COUNT = yy An example of a DCONADD entry that causes this error is as follows:

Description

DCONADD, 1, 10, 11, 12, 13, 14, 15, 16, +DCON1 +DCON1, 17, 18, 19, 20, 21, 22, 23, 24, +DCON2 +DCON2, 25 $ Note that the second continuation entry contains a single DCONSTR entry (25 in this case). Avoidance: Add a dummy DCONSTR to the DCONADD continuation entry. The limits should be set to a large value to ensure that the constraint screening will remove this constraint prior to performing optimization. A suggested lower bound (LALLOW)

Known Error

CR 5956

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

Old Design Sensitivity - PARAM,POST,-2 - Missing Datablocks In MSC/NASTRAN Version 68, if sensitivity output (SENSITY command) is requested using SOL 103 in conjunction with param,post,-2, not all datablocks are written to the output2 file. Note this error applies only to the old design sensitivity method. It does not apply to the new sensitivity calculation (SOL 200).

Known Error

CR 5956 Avoidance: Insert the following DMAP alters.

compile super3 souin=mscsou nolist noref $ alter 90,90 $ gp1 GEOM1,GEOM2,,,/GPL,EQEXIN,GPDT,CSTM,BGPDT,SIL,/0/0/0 $ alter 208,208 $ alter 211,211 $ Known Error

CR 5960

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Buckling Analysis - EIGRL, SYSTEM(146) - SFM 5407, SFM 5401, SFM 4276 If SYSTEM(146) is set to save scratch space and reduce I/O in sparse decomposition during a Lanczos eigenvalue buckling run, then the job fails. Different fatal messages have been encountered including "SYSTEM FATAL MESSAGE 5407 INERTIA (STURM SEQUENCE) COUNT DISAGREES WITH THE NUMBER OF MODES ACTUALLY COMPUTED IN A (SUB-) INTERVAL", "SYSTEM FATAL MESSAGE 5401 (REIGL) LANCZOS METHOD IS UNABLE TO FIND ALL THE EIGENVALUES IN RANGE" AND "SYSTEM FATAL MESSAGE RECOVERY ERROR CODE 7777" in sparse decomposition. Avoidance: Do not use SYSTEM(146) during a Lanczos buckling run.

Known Error

CR 5961

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Heat transfer - SET1, RADCAV - Wrong Answers

Description

If the SET identification pairs for the calculation of global view factors exceeds 10 pairs, then an erroneous result is output for the global view factors. The documentation states that only 10 pairs can be shown for one run. This limit is expanded to 30 in Version 68.2.

Known Error

CR 5962

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Acoustic Analysis - REIGL, SUPORT, MERGE - UFM 4276, EC 3007

Description

SUPORT entries do not work in acoustic analysis. USER FATAL MESSAGE 4276,

Known Error

CR 5962 ERROR CODE 3007 from subroutine merge called from the REIGL module is issued. Other eigenvalue extraction methods result in other fatal messages. Avoidance: Remove SUPORT entries.

Known Error

CR 5963

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Case Control - STRAIN(CORNER) - Missing Output

Description

If a STRAIN(CORNER) request is made without a STRESS(CORNER) request, only centroidal strains are output. Avoidance: Request STRESS(CORNER,PLOT) in the Case Control Section.

Known Error

CR 5977

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Buckling Analysis - SPCD - Wrong Answers If SPCD entries are used in SOL 105 and the SUBCASE used for the buckling analysis does not contain a call for a LOAD set using the SPCDs, the SPCD entries are ignored in the solution. Avoidance: Either use different SPC sets for each SUBCASE, or include a LOAD command in the buckling SUBCASE pointing to the SPCD set.

Known Error

CR 5982

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Eigenvalue Analysis - AGIV, AHOU - SDCOMP FATAL ERROR, UIM 5458 If an eigenvalue analysis specifies either the AGIV or the AHOU method, then standard GIV and standard HOU are attempted first. If the mass matrix is singular, an unnumbered fatal message "SDCOMP FATAL" is issued even though the problem continues and the program switches to the modified Givens or Householder method. Avoidance: If the problem runs, ignore the FATAL message.

Known Error

CR 5983

Product

MSC / MD Nastran

Known Error

CR 5983

Corrected Version 69 Abstract

Description

Optimization/Design Sensitivity - DOPTPRM, DOM10 - SFM 3001 An optimization run with P1=1 and P2=15 on the DOPTPRM entry fails and issues "SYSTEM FATAL MESSAGE 3001" from the DOM10 module even though the run works fine without these parameters. These are output control parameters and should not effect the solution. Avoidance: If P1 and P2 have been used on the DOPTPRM and the run fails, try the run again without specifying P1 and P2.

Known Error

CR 5984

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Nonlinear Analysis - PARAM,NMLOOP , SE's - Missing Output When using the nonlinear normal modes option in Sol 106, no modal analysis is performed when there are superelements and PARAM,NMLOOP is specified in the Case Control. Avoidance: Place the PARAM,NMLOOP statement in the bulk data. or

Description

Use SUPER=ALL in the case control. or DMAP alter: compile nlstatic souin=mscsou nolist noref $ alter 480 $ seid= 0 $ pvt pvts,cases/pvtxx/ $ endalter $

Known Error

CR 5987

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Postprocessing - PARAM,POST,-2 - IDEAS Dataloader Abort

Known Error

CR 5987 In MSC/NASTRAN Version 68, the structured solution sequences with PARAM.CHECKOUT,YES and PARAM,POST,-2 do not write an END-OF-DATA on the FORTRAN file.

Description

Avoidance: COMPILE PHASE0 SOUIN=MSCSOU NOREF NOLIST ALTER 527 $ Before CALL PRTSUM OUTPUT2 //-9/OUNIT1//OMAXR $ write END-OF-DATA CEND

Known Error

CR 5993

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Documentation - PBEAM - Continuation Entries The documentation for the PBEAM entry in the MSC/NASTRAN Version 68 Quick Reference Guide states that the fields "SO" and "X/XB" on the second continuation entry are required. A footnote should be included (as was in the Version 66 User's Manual) that states that these fields are only required when the second continuation entry is desired to request intermediate stress output.

Known Error

CR 5995

Product

MSC / MD Nastran

Corrected Version GL Abstract

Elements - QUAD4, TEMP(LOAD) - Wrong answers

Description

Warped QUAD4 elements with thermal loads give wrong answers. This error is similar to the thermal expansion error in elements with rigid offsets, there is no expansion for the offset. If offsets and orthotropic materials are present, the errors are magnified.

Known Error

CR 5998

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Documentation - Linear Static Analysis User's Guide - Wrong output

Description

Incorrect output result files are included in Figures 11-2 and 11-3 of the MSC/NASTRAN Linear Static Analysis User's Guide. Due to a missing carriage control character, a pload1 entry for element # 2 is missing for the inertia2.dat

Known Error

CR 5998 file that is delivered with the delivery tape. Furthermore, due to error 5522, PLOAD1 yields incorrect results for the BAR, BEAM, or BEND elements when used in conjunction with inertia relief. Thus, this example (using PLOAD1) should not be emulated until error 5522 is corrected. Avoidance: Replace the PLOAD1 with equivalent grid point loads and regenerate the output file.

Known Error

CR 6000

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Transient Analysis - RESTART, PARAM,NOAP - Poor Answers If TIC entries are used to set initial velocity values, the computed initial velocity will be slightly different from the specified initial velocity. On a case where v0 was set to 1.0, the output velocity was computed as 0.9969. This model has a dt of 0.1

Description Avoidance: An avoidance is to run the model once to determine the computed initial velocity, and increase the input initial velocity enough so that the computed intital velocity is the value desired on a second run. Known Error

CR 6004

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

SSSALTER Library - ZFREQ - Wrong Answers The ZFREQ alter delivered in the Version 68 SSSALTER library allows frequency dependent springs and dampers to be defined. However, the nominal spring stiffness is not updated in the data recovery phase. Thus, element force output for these elements is incorrect. This is a known limitation of the alter that should have been documented in the ZFREQ.RDM file. The information contained in this error report is to be included in the Version 68.2 ZFREQ.RDM file and the error is considered corrected. Avoidance: An avoidance is to place a stiff spring in series with the mount, the forces in the stiff spring represent the correct element force for the mount spring. The error introduced by this technique is proportional to the ratio of the stiff spring rate to the mount spring rate. For e

Known Error

CR 6007

Known Error

CR 6007

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Documentation - PARAM, USETPRT PARAM, USETEL - K-set is not Output

Description

The MSC/NASTRAN Quick Reference Guide incorrectly states that the parameters usetprt and usetsel can be used to print k-set degrees of freedom. That is, the k-set decimal equivalent is listed as an option in table 1 of the usetprt parameter description.

Known Error

CR 6010

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

Nonlinear Slide Line Contact - BCONP, BLSEG - Wrong Answers An overhang slave node is not considered as "overhang" if the overhang value is less than 5% of the master segment length. For models with large master segments, this may lead to wrong answers. Typical symptoms include the printout of a wrong slip code (e.g., SLIDE instead of OVERHANG) and incorrect surface coordinates. Avoidance: Use smaller master segments when modeling overhang situations.

Known Error

CR 6011

Product

MSC / MD Nastran

Corrected Version 70 Abstract

Security - NAO - UFM 3060, Segmentation Fault, Signal Number 11 in Log File

Description

Large jobs that use Network Authorization (NAO) may fail in various moudules on the DEC/ALPHA OSF with the message, "Receiving signal number 11: Segmentation fault", in the MSC/NASTRAN log file. Similarly, if using node lock authorization, and running a looping solution sequence like nonlinear and a large problem, then User Fatal Message 1019 "Fortran Unit Open Error" pointing to the authorization file may be issued. This message is followed by USER FATAL MESSAGE 3060. The problem occurs because a socket (file) is left open each time MSC/NASTRAN checks the authorization code and when the system reaches the open sockets limit, the job fails as indicated above.

Known Error

CR 6011 Avoidance: Edit the system configuration table (sysconfigtab) and increase the value of the OPEN_MAX parameter. (This is a syste

Known Error

CR 6012

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Dynamic Response Analysis - EPOINT - Single Precision Accuracy

Description

If there are EPOINT entries in the bulk data file, the eigenvalue matrix PHIA is expanded to the d-set matrix PHIDH in the GKAM module. On shortword machines PHIA is double precision. At present PHIDH is single precision. As this matrix is used to reduce load matrices and expand modal solutions to physical DOFs this may reduce the precision of the solution. Avoidance: An avoidance is to discard the PHIDH matrix output by the GKAM module and build an alternate matrix with DMAP. The equations defining how PHIDH is formed from PHIA are given in the MSC/NASTRAN REFERENCE MANUAL.

Known Error

CR 6013

Product

MSC / MD Nastran

Corrected Version 69 Abstract

DMAP - DMIG - Wrong Answers If a DMIG entry references a degree of freedom which does not exist, the corresponding coefficients are assigned to another degree of freedom, without any diagnostic messages.

Description In one example, an open set was used to define a series of scalar points. A DMIG term referenced a point that was not defined on an SPOINT entry which occurred between two points which were listed on SPOINT entries. The coefficient was placed on the last DOF. Known Error

CR 6015

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Documentation - Aeroelastic Users' Guide - UFM 2268 (FA1)

Description

Example HA145I in the Version 68 Aeroelastic User's Guide contains an alter that is in error. The alter inserts a MATPRN after line 50. It should be after line 45. If submitted as documented, the run fails and issues the message "USER FATAL MESSAGE 2268 (FA1) FMETHOD SET 0 NOT FOUND".

Known Error

CR 6015 The data deck delivered in the tpl has been made current. The documentation will be updated to reflect the latest version when it is updated.

Known Error

CR 6016

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

P-Elements - HEXA, PENTA - Excessive Pivot Ratios at p=2 (UFM 9050) If a model consists of HEXAs or PENTAs at a p-level=2 or higher connected end-to-end, the following message may occur: DMAP FATAL MESSAGE 9050 (SEKRRS) - RUN TERMINATED DUE TO EXCESSIVE PIVOT RATIOS IN MATRIX KLL. USER PARAMETER BAILOUT MAY BE USED TO CONTINUE THE RUN. This fatal message is caused by the reduced integration used at a p-level=2 and higher. Reduced integration is the current default. Avoidance: SYSTEM(212)=1 may be set to work around the problem.

Known Error

CR 6017

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Nonlinear Slide Line Contact - BCONP, BLSEG - Extraneous Output The following parameters are printed in the "LINE CONTACT REGION" output when using the slide line contact capability. CONT BEHA FO CO TYPE

Description These values should be ignored as they are not implemented in the program. Avoidance: These values have no effect on the rest of the output and they can be safely ignored. Known Error

CR 6024

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Optimization/Design Sensitivity - DLINK - Wrong Answers

Description

If the user inputs a nonzero value for C0 on the DLINK entry, it is incorrectly

Known Error

CR 6024 processed by the optimization algorithm. Values used by the optimizer for the dependent design variables will be incorrect. This will directly affect constraint calculations from the upper and lower bounds input on the associated DESVAR entry. These constraints may not be critical and and the optimization results may be valid. The printed summary values for the dependent design variables will be incorrect. Avoidance: There is no avoidance.

Known Error

CR 6030

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Optimization/Design Sensitivity - MPCFORCE, PARTN, DSAP - UFM 2166, UFM 5901 In Version 68, if MPC forces are requested in an optimization run under static analysis, the program fails at line 121 of subDMAP SEDISP with UFM 2166 stating that the number of columns in the partition vector is incorrect. Under frequency response analysis, UFM 5901 will be issued from the DSAP module.

Description

Avoidance: Either remove the MPCFORCE output request or apply the following DMAP alter to avoid the error: $for statics approach: compile sedisp, souin=mscsou, nolist, noref alter 109 noqmg=ltoi(delta) $ $ For Frequency approach: compile sedisp, souin=mscsou, nolist, noref alter 238 if (not delta ) then $ alter 239 endif $

Known Error

CR 6031

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Documentation - gentim2.dat - Data File Not Found

Description

The MSC/NASTRAN V68 Installation and Operation Instructions implies that the gentim2.dat file used to update timing constants is in the same directory with the SSS.MASTERA and USS.MASTERA (ie /msc68/nast68/aix/del) but it

Known Error

CR 6031 is not. The file is located in the /msc68/nast68/del directory. The install guide should be clarified to tell users where the data file is located.

Known Error

CR 6033

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Elements - TETRA(10), TEMP(LOAD) - Wrong Answers for TETRA(10) Stresses If the temperature at the grid points of a TETRA(10) element vary (i.e. they are not constant), then the stresses for the element are incorrect.

Description

Avoidance: The error is proportional to the variance of temperature within the element; however, refining the mesh so that the temperature within each element is near a constant is not considered a practical avoidance. Stresses requested at the gauss points are correct.

Known Error

CR 6036

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

P-Elements - Punch Output not Supported

Description

When stresses and strains are output in the punch file, they are output in the print file (F06) format, with titles and labels, rather than a format suitable for the punch file.

Known Error

CR 6038

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Elements - CTRIA3, TA1 - No Message, Trap Encountered

Description

If a CTRIA3 element references a nonexistent material coordinate system (field 7), the job should issue USER FATAL MESSAGE 2025 UNDEFINED COORDINATE SYSTEM. The IBM RS/6000 versions of MSC/NASTRAN do not issue this message. The job stops without a message being issued. The f04, Execution Summary, indicates that the last module executed is either TA1 or PHASE1DR and the log file contains a "Trap Encountered" message.

Known Error

CR 6042

Product

MSC / MD Nastran

Corrected Version GL

Known Error

CR 6042

Abstract

Elements - PENTA(6), TEMP(LOAD) - Wrong Answers for Stresses

Description

If the temperature at the grid points of a PENTA(6) element vary (i.e. they are not the same at all points), then the stress output is wrong. Both corner point (default) and Gauss location (selected on PSOLID) options give wrong answers. The stress error is proportional to the amount of temperature change within the element. Avoidance: This is a limitation of the element. The only avoidance is to refine the mesh so that the variation of temperature within the element is minimal.

Known Error

CR 6044

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Optimization/Design Sensitivity - Incorrect Sensitivities for Superelements Incorrect design sensitivities are computed for superelement models in which a superelement has design variables but no design responses. This error occurs only in statics.

Description Avoidance: The avoidance is to specify WEIGHT=ALL (for all superelements) as a design response.

Known Error

CR 6046

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Optimization/Design Sensitivity - PARAM,DESPCH - Incorrect Action Setting PARAM,DESPCH to a negative value will not prevent DESVAR and GRID Entries from being written to the PUNCH file. Avoidance: The following DMAP alter may be used to avoid the problem:

Description

compile exitopt nolist noref souin=mscsou alter 24 $ just before executing module DOM11 type parm,,i,n,desitert if (despch < 0) then desitert = desiter desiter = 0 endif

Known Error

CR 6046 alter 25 $ right after execution of module DOM11 if (despch < 0) then desiter = desitert endif $$$ end of alter

Known Error

CR 6047

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

Description

SSSALTER Library - RESFLEXR - Wrong Answers The alter to add residual vectors into a dynamic solution delivered in the sssalter directory with Version 68 does not handle SUPORT entries properly for free-free structures. If a SUPORT entry is present, residual vectors are not generated for the residual structure. Avoidance: Call MSC for an updated version of the alter.

Known Error

CR 6050

Product

MSC / MD Nastran

Corrected Version 68.2 Abstract

P-Elements - GMLOAD in convective coordinate systems If a GMLOAD is applied in a convective coordinate system defined on a GMCURV or GMSURF where the CIDIN is other than basic coordinate system, then the following message is output from SSG1:

Description

USER FATAL MESSAGE 2025, UNDEFINED COORDINATE SYSTEM 2 FATAL ERROR Avoidance: Possible avoidances include defining the GMCURV or GMSURF in the basic coordinate system, and applying the load in a non-convective system, or using PLOAD4.

Known Error

CR 6051

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Documentation - MAT1 - Programs Action not Clear

Description

Remark 3 under the documentation for the MAT1 entry in the Quick Reference Guide states that the relationship between E, G and NU "must be satisfied". It should be clarified that satisfying the relationship is merely a

Known Error

CR 6051 recommendation, rather than a requirement. The values furnished are used as indicated in Table 1. and if the relationship is not satisfied the program proceeds but issues USER WARNING MESSAGE 2251A and 2251B. Furthermore, the relationship indicates ">" when it should indicate " 101) Avoidance: Remove Diag 14 and/or Diag 64.

Known Error

CR 7013

Product

MSC / MD Nastran

Corrected Version GL Abstract

Miscellaneous - COMIFP, PUNCH - Produces Incorrect Bulk Data Entries

Description

The comifp module has been modified for Version 69 to support the part superelement concept. It can take ifp-like files from the sep2 module and punch bulk data files which may then be used as part files. At present, the RBE2 and RBE3 elements are punched incorrectly. Avoidance: An avoidance is to separate the elements not properly processed by hand.

Known Error

CR 7014

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Heat Transfer Analysis - MAT4, CONVM, EMG - FATAL ERROR, Bad Diagnostic Message If the user fails to define a dynamic viscosity in field 7 of the MAT4 entry for a forced convection analysis the job fails in the EMG module with no indication of the cause of the error. Avoidance: Make sure the dynamic viscosity is input on the MAT4 card if

Known Error

CR 7014 the problem has CONVM bulk data entries.

Known Error

CR 7015

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Material Nonlinear Analysis - TEMP(LOAD), CLOAD - Wrong Answers In Version 68.2 and SOL 106 only, thermal loads applied to upstream superelements results in incorrect stresses and forces. Avoidance: Use SOL 66 or apply the following alter to SOL 106:

Description compile super3 noref nolist alter 'IF ( NOCASRS1>-1 AND SEID=0 )','' IF ( (NOCASRS1>-1 AND SEID=0) or app='nlst' ) THEN $

Known Error

CR 7021

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Optimization/Design Sensitivity - DSCM2 - Wrong Ordering In design sensitivity analysis, there is a table printed just prior to the DSCM2 (design sensitivities matrix) which specifies the ordering of the columns in the matrix. If some of the design responses specified on the DRESP1 entry are the eigenvalues, then the table claims that the eigenvalue responses are in ascending order by DRESP1 entry ID. However, the matrix is actually in ascending order by mode number. Avoidance: The only avoidance is to be aware that the output is in ascending order by mode number.

Known Error

CR 7040

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Documentation - DRESP1 - UFM 316

Description

The documentation for the DRESP1 entry in the MSC/NASTRAN Version 68 Quick Reference Guide states that the SPC force component is chosen with the RTYPE=FRSPC or RTYPE=TSPC. However, if either of these RTYPEs are used, the following fatal message is issued, "USER FATAL MESSAGE 316 (IFPDRV) ILLEGAL DATA ON

Known Error

CR 7040 BULK DATA CARD DRESP1 331 SORTED CARD COUNT = ***". The documentation should say the the SPC force component is chosen with RTYPE=FRSPCF or RTYPE=TSPCF. Avoidance: Use RTYPE=FRSPCF or RTYPE=TSPCF not FRSPC or TSPC when the SPC force component is desired as a response type.

Known Error

CR 7041

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Nonlinear Analysis - EMG - Poor Performance NO EXTERNAL ERROR REPORT

Description

When there are no linear elements in a model, the EMG module is unnecessarily executed. This appears to be a minor performance improvement, I see no need to publish to clients.

Known Error

CR 7044

Product

MSC / MD Nastran

Corrected Version 69.1 Abstract

Description

Nonlinear Transient Heat Transfer - QVECT, DLOAD - Wrong Answers Scaling by other than 1. of a vector flux QVECT load by a DLOAD bulk data entry produces wrong results in the "APPLIED-LOAD" column of the "Heat Flow into HBDY Elements" table. The actual load vector generated is correct and therefore the temperatures are correct. Avoidance: Use only scale factors 1 on the DLOAD entry.

Known Error

CR 7045

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Case Control - SUBCASE - Poor Message

Description

The message " *** USER FATAL MESSAGE 609 (IFP1D) SUBCASE DELIMITER CARDS MUST HAVE A UNIQUE IDENTIFYING INTEGER " which does not accurately describe

Known Error

CR 7045 the input error is issued for the following situation: 1. When the subcase id exceeds 9999999. 2. In solution 200 when the subcase id of the preceding subcase is higher than the id of subsequent subcase.

Known Error

CR 7047

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Aeroelastic Analysis - Unwanted Output in the Flutter Summary In the pk flutter solution, all combinations of velocity, Mach number and density are used. In certain situations (e.g., if analyses are only required at 50 velocity-density combinations) it would be preferable to only do ordered combinations.

Description Avoidance: The current avoidance is to put each required combination in its own subcase. For the example given above, this would require 50 subcases, but it would reduce the number of flutter analyses from 2500 to 50. Known Error

CR 7048

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Submittal Script - node - Error With node Keyword When the "node" keyword is used along with the "user" keyword ( i.e. nastran ..... node=pelee user=ssp) then job will not get submitted to remote node and the following message will be displayed on the console: nast68: (W) node=pelee specified, setting app=yes bat=no scr=yes nast68: (E) node=pelee: no execute permission on remote node.

Description Avoidance: The following line in the nastran shell script should be changed. The shell script is $MSC_INSTALLDIR/bin/nastran. rx="$remcmd $tuser $node" should be changed to

Known Error

CR 7048 rx="$remcmd $node $tuser"

Known Error

CR 7050

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Multipoint Constraint - MPCFORCE Output - Labeled as SPCF in .pch file

Description

MPCFORCE output when printed to a punch file, is mis-labeled as SPCF. The data is correct however. Confusion may arise when both SPCFORCE and MPCFORCE are printed to the punch file. The user must use care to read the correct results. The error is considered fixed in Version 69; however, setting of SYSTEM(210)=1 is required. Avoidance: Print and punch the data so that the output can be compared and correlated.

Known Error

CR 7053

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Documentation - DVPREL1 - UFM 2042 Misleading The DVPREL1 entry is used to define a relationship between an analysis model property and a design variable. However, not all analysis model properties are valid choices. For example it is not valid to link the MID field on a property entry (which is an integer) to a design variable (which is always real). If this is done the MATi entry in the analysis model is overwritten with a nonexistent MATi and then the following misleading message is issued, "USER FATAL MESSAGE 2042, MISSING MATERIAL TABLE******** FOR ELEMENT xx". Invalid choices for the analysis property chosen on the DVPREL1 should be screened out prior to the start of optimization. Avoidance: Choose only valid analysis properties on the DVPREL1.

Known Error

CR 7055

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Documentation - Composites, Buckling, PSHELL, PCOMP - Missing

Known Error

CR 7055 Documentation The following remark should be added to the PSHELL bulk data entry description in the MSC/NASTRAN Quick Reference Guide: The use of MID4 will cause incorrect results in buckling analysis and differential stiffness.

Description The following remark should be added to the PCOMP bulk data entry documentation in the MSC/NASTRAN Quick Reference Guide: An unsymmetric layup or the use of ZO to create an unsymmetric layup will cause incorrect results in buckling analysis and differential stiffness. Known Error

CR 7059

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Miscellaneous - DMIG - Psuedo Infinite Loop, Device Full

Description

If characters are input in the NCOL field of a DMIG header entry and the matrix is rectangular (IFO=9), then the MTRXIN module may be caught in a pseudo infinite loop which may be finally stopped by a "device full" message. The MTRXIN module interprets the characters in NCOL as an integer and this is normally a huge number. The IFP module should stop the execution with "User Fatal Message 327" in case that the input for NCOL is not an integer.

Known Error

CR 7065

Product

MSC / MD Nastran

Corrected Version 69 Abstract

P-Elements - Wrong Adaptivity Analysis - Poor Answers

Description

If a data deck contains different TYPEs of P-elements (e.g. a HEXA and a PENTA), the adaptivity error analysis likely to be in-accurate leading to poor answers. Avoidance: There is no avoidance.

Known Error

CR 7073

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Heat Transfer - PARAM,POST,-2 - SDRC Cannot Read TEMP Vector

Known Error Description

CR 7073 SDRC is not able to read the temperature vector in the output2 file produced with PARAM,POST,-2. Avoidance: Use EQUIVX instead.

Known Error

CR 7076

Product

MSC / MD Nastran

Corrected Version Abstract

Description

Timing Estimate - DECOMP - UIM 4157 The CPU time estimates issued in USER INFORMATION MESSAGE 4157 for sparse decomposition can be overstated by a factor of 7 to 15 times on some machines. This is due to the fact that the timing estimates do not take into account the high rank performance update enhancement which was introduced beginning in Version 68.1. By overstating the CPU time estimates the job may fail with a message that it does not have enough time to complete Decomposition. Avoidance: Include an extra large value for time on the TIME executive control entry or remove the TIME entry.

Known Error

CR 7085

Product

MSC / MD Nastran

Corrected Version 70.5.2 Abstract

Cyclic Symmetric - Dihedral, LOADCYH, DSYM - UFM 4342 A cyclic symmetry analysis using dihedral symmetry and centrifugal loads may issue the following message: USER FATAL MESSAGE 4342, THE LOAD BULK DATA CARD GIVEN BELOW IS INCONSISTENT WITH SPECIFIED ANALYSIS HARMONICS OR SEGMENTS OR SYMMETRY TYPE. LOADCYH 20 0CSTAR 2000004

Description The message occurs when a SS (Symmetric=Symmetric) boundary condition is specified on the DSYM case control command and the LOADCYH bulk data requests an 'RLOAD' for the HTYPE field. In this condition the code generates too many load vectors. Avoidance: One avoidance is to change the HTYPE field to 'C' on the

Known Error

CR 7085 LOADCYH bulk data entry. A better avoidance is to eliminate the DSYM request in the case control.

Known Error

CR 7088

Product

MSC / MD Nastran

Corrected Version 70 Abstract

Documentation - PSHELL, MID4, ZOFFS - MID4 and ZOFF may be combined

Description

Remark 6 under the description of the PSHELL entry in the Version 68 Quick Reference Guide states that "Only one of the options MID4 or ZOFFS may be used". This is a guideline to prevent users from offsetting the element twice. Depending on the intent of the user these affects may be combined and correct answers achieved.

Known Error

CR 7093

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Description

Complex Eigenvalues - CLAN - Wrong Answers For one model, the complex lanczos eigenvalue method in solution 107 produced erroneous eigenvalues on the CRAY computer. The same model produced consistent real eigenvalues across all machines so there does not appear to be anything wrong with the model. MSC/NASTRAN Version 70.5 introduces the new Block Complex Lanczos method. This method correctly solves this problem on CRAY and all other machines. This method must be selected in Version 70.5 by setting system(108)=4 on the NASTRAN entry or rc file. Avoidance: Until the error is better understood, use SOL 110, modal complex eigenvalues, with the Hessenberg Method.

Known Error

CR 7100

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Static Analysis - SPC - UFM 5423

Description

A DMAP error exists in multiple boundary condition with non-zero SPC in SOL 101. The error is triggered when the same boundary conditions are not grouped together, i.e., the same SPC is selected again following

Known Error

CR 7100 a SUBCASE with a different SPC. The error is detected by the SSG2 module with a UFM 5423 "attempt to multiply incompatible matrices." This error is related to error 5977 which is detected when SPCD is used instead of non-zero SPC. Avoidance: 1. Shuffle the Subcases so that the same boundary conditions are grouped together (to appear consecutive Subcases). 2. Use SOL 106 with unsorted SUBCASE set-up and run it as a linear problem without any nonlinearity.

Known Error

CR 7108

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Acoustic Analysis - SDR1, MPYAD - Insufficient Time Acoustic Analysis in MSC/NASTRAN does not support the matrix method of data recovery. Thus, the data recovery performed by the modal displacement method for small sets of data is very inefficient. This deficiency is complicated by poor timing estimates in MPYAD. MPYAD, which is called by SDR1 during the data recovery, may yield a time estimate that overflows the machine. Version 69 will support data recovery in the DDRMM module, i.e., the matrix method.

Description Avoidance: There is no simple avoidance. Perform modal reduction on the fluid and limit the number of frequencies in the analysis. The following alter can be applied to recover pressure only by the matrix method. compile semfreq souin=mscsou noref nolist alter 74 lamx ,,lamas/mlamas/-1 $ lamx ,,lamaf/mlamaf/-1 $ ma Known Error

CR 7109

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

DMAP - MATMOD OPTION 17 - Wrong Answers

Description

MATMOD option 17 generates a g-size partitioning vector from a userdefined

Known Error

CR 7109 set of grid and/or scalar points. If the 3rd parameter (SETFLG) is set to 1, it is supposed to look for the PARTN case control command and put a value of 1.0 in the vector for grid points listed in the set defined by the PARTN case control command. If there is no PARTN case control command, it is supposed to use the sets defined by the 2nd parameter (UBIT). However, the above operation returned a vector with all values set to 1.0 instead. Depending on subsequent operations, this can either lead to fatal errors or wrong answers. Avoidance: Include the appropriate PARTN case control command.

Known Error

CR 7110

Product

MSC / MD Nastran

Corrected Version 69 Abstract

SSSALTERS - evds.v682 - Fails to Converge When using the eigenvector sensitivity dmap alter (evds.v682) delivered with the sssalter library in Version 68.2, and the model does not contain any elements which references a mass property entry, then the job may fail to converge. Avoidance: Replace the following dmap statement in evds.v682 subdmap fox:

Description

TYPE PARM,,I,N,NULLDM $

with

TYPE PARM,,I,N,NULLDM,NZWD $

Known Error

CR 7118

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Documentation - ADUMi, PDUMi - Undocumented Limits, User Modifiable NASTRAN

Description

The number of additional fields "NP" on the PDUMi entry is limited to 24 words. This limit is not documented in the description of th NP field of the ADUMi bulk data entry description.

Known Error

CR 7127

Product

MSC / MD Nastran

Known Error

CR 7127

Corrected Version 69 Abstract

Optimization/Design Sensitivity - PARAM,SNORM - UFM 2025 in module TA1 If in SOL 200, parameter SNORM is greater than or equal to 0.0 and if a coordinate system is specified in the MCID field of the connectivity entry in the run then the following fatal message will be issued. *** USER FATAL MESSAGE 2025 MODULE = TA1 UNDEFINED COORDINATE SYSTEM 3 This error might also occur in SOL 101 and 103 if p-element adaptive analysis is performed.

Description

Avoidance: Two avoidances exists: 1. Remove the SNORM parameter. 2. Add the following alter. compile update souin=mscsou nolist noref alter 51,51 $ TA1 ,,ECT,EPTX,BGPDTSCR,SIL,,CSTMSCR,/ ESTJNK,,,GPECT0,/ LUSETS/-1/S,N,NOSIMP/1/S,N,NOGENL/0 $

Known Error

CR 7136

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Restarts - MAT2, IFPL, RESTART - DEC Alpha Only Aborts on Restart

Description

There is an error in the nddl for the MCSID field of the MAT2 entry. The nddl types the field as real when it should be an integer. If this field is changed in a RESTART the execution will fail. The message "time: command terminated abnormally" is issued in the log file.

Avoidance: The run should be executed as a cold start. Known Error

CR 7137

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Postprocessing - PARAM,POST,-2, SOL 112 - Extra Output

Description

In SOL 112 with PARAM, POST, -2, the geometry tables are written twice to the OUTPUT2 file. However, this does not seem to negatively affect the IDEAS translator.

Known Error

CR 7137 Avoidance: There is no avoidance.

Known Error

CR 7138

Product

MSC / MD Nastran

Corrected Version 70 Abstract

Description

Documentation - Common Questions and Answers - Incorrect Problem Descriptions The problem description on page 103 of the Common Questions and Answers ,2nd Edition, does not match figure 40 on the same page. The acceleration should be negative, as is reflected in fig. 40 and the 3 in field 5 of the RLOAD2 entry should be moved to field 6. The title for figure 39 on page 101 of the Common Questions and Answers book refers to point loads when in fact the example discusses pressure loads (PLOAD4s).

Known Error

CR 7139

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Executive System - COMPILE - Segmentation or Access Violation An attempt to compile the NDDL and more than 75 subDMAPs in a single run causes a segmentation or access violation. The limit in Version 69 has been expanded to allow for at least 100 subdmaps. Avoidance: Split the job into two runs.

Known Error

CR 7141

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Description

Known Error

Nonlinear Transient Analysis - CBEAM - UFM 4551 (NL2CON) It has been found that in rare cases when then the orientation vector for a beam element is exactly normal to the axis of the beam, the Cray may exhibit a round-off error that leads to convergence difficulties and ultimately USER FATAL MESSAGE 4551, STOPPED PROBLEM DUE TO FIVE CONSECUTIVE DIVERGING TIME STEPS.

CR 7142

Known Error

CR 7142

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Optimization/Design Sensitivity - DOPR3 - SFM 4276 If the user provides constraints for multiple DRESP1 entries in a single flutter subcase, then SYSTEM FATAL MESSAGE 4276 GREAD ERROR CODE 3001 will occur in the DOPR3 module. Avoidance: If it is not possible to define all the flutter responses on a single DRESP1 entry, multiple flutter subcases are required, each with a single referenced DRESP1 entry.

Known Error

CR 7144

Product

MSC / MD Nastran

Corrected Version Abstract

Description

Nonlinear Transient Analysis - OTIME - Missing Output In nonlinear transient analysis (SOLs 129 and 159), the solution vectors (SDISP, SVELO, and SACCEL) should be output for each subcase independently. However, SDISP, SVEL, or SACCEL does not appear in the output unless the request is specified above the subcase. Avoidance: Specify the output request for SDISP, SVELO, or SACCEL above the subcase level.

Known Error

CR 7147

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Utilities - OPTCONV - Fails On Windows NT If the OPTCONV program delivered with the Windows NT version of NASTRAN is used to convert an old optimization deck to the current format, the following message is obtained in a pop-up window: "The instruction at 004147cc referenced memory at 0d4212b9 The memory could not be written Click on OK to terminate the application". Therefore, it is not possible to convert any old optimization decks on Windows NT. Avoidance: Convert the decks by hand or have them converted on a different machine variation.

Known Error

CR 7156

Product

MSC / MD Nastran

Corrected Version 69 Abstract

P-Elements - PARAM,USETPRT,0 - Incorrect Output PARAM,USETPRT,0 produces incorrect output for P-Elements.

Description Avoidance: Use PARAM,USETPRT,1 instead. Known Error

CR 7163

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Nonlinear Static Analysis - ASETi, OMITi, AUTOSPCR - UWM 5225, Wrong Answers In nonlinear static analysis, any nonlinear degree of freedom in the o-set (via ASETi or OMITi entries) may result in a singularity in the o-set linear stiffness matrix (UWM 5225). Also, if PARAM,AUTOSPCR is used, all the nonlinear degrees of freedom will be constrained and the resulting solution will be incorrect. Avoidance: Include all the active nonlinear degrees of freedom in the A-set.

Known Error

CR 7167

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Nonlinear Heat Transfer - UIM 6194, UIM 6193, UFM 4551 Nonlinear Heat Transfer jobs with more than one subcase may fail to converge and issue UIM 6194, UIM 6193 and USER FATAL MESSAGE 4551. This error was experienced in a job where the second subcase was the same as the first. The job should have converged immediately in the second subcase since there was no change.

Description

USER INFORMATION MESSAGE 6194, STOPPED ITERATIONS DUE TO REACHING MAXIMUM ITERATION LIMIT WITHOUT CONVERGENCE *** USER INFORMATION MESSAGE 6193, MAXIMUM NUMBER OF BISECTIONS OR MINIMUM LOAD STEP HAS BEEN REACHED. USER FATAL MESSAGE 4551,

Known Error

CR 7167 STOPPED PROBLEM DUE TO FAILED CONVERGENCE

Known Error

CR 7170

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Heat Transfer - CHBDYP, LINE with midpoint node option Currently there is a design limitation using CHBDYP,LINE to represent thhigher order CQUAD8 or CTRIA6 for the edges with midpoint option. Therefore, the weighting on the mid-side node is misrepresented if the two node LINE option is used. Avoidance: Use CHBDYE to represent the CQUAD8 or CTRIA3 element with midsidenodes. Please note that without the midside node, the CHBDYP,LINE can be used.

Known Error

CR 7171

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - Reference Manual - Large Field description There is an error in the Reference Manual documentation for the description of the Small/Large/Free field format of the bulk data entries as follows:

Description

pp 3.7.1-2 Bottom of the page, Large Field example. The first field of the parent card should be TYPE* not TYPE. The continuation of the parent card should be QED123 not QED124. pp 3.7.1-3 Top of the page, Large field with large field continuation example. This is shown as all small fields. There should only be 4 (double wide) fields between the first and last fields.

Known Error

CR 7173

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

P-elements - CHEXA - UFM 9050 CHEX p-Elements can have singularities in the stiffness for the default integration options. This error only occurs in a model with a single layer of elements. In particular the default reduced integration order with rectangular elements with p values of [2,2,3] in the three directions may be singular. This error may lead to the following fatal message: USER FATAL MESSAGE 9050 (SEKRRS) - RUN TERMINATED DUE TO

Known Error

CR 7173 EXCESSIVE PIVOT RATIOS IN MATRIX KLL. USER PARAMETER BAILOUT MAY BE USED TO CONTINUE THE RUN. Avoidance: Specify a different p value.

Known Error

CR 7175

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Documentation - CALL DBFETCH - DMAP Module Dictionary

Description

The description of the DBFETCH command in the DMAP Module Dictionary should enhanced to state "if you are using DBFETCH in a Sol 100 (USER DMAP) to get data blocks from a previous run, include a RESTART FMS statement to specify the version number on which the data blocks were written".

Known Error

CR 7176

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Direct Frequency Response - CHACAB - Wrong Answers The damping terms for the acoustic absorber element, CHACAB, are "lost" in solution 108 resulting in null damping from this element.

Description Avoidance: Place equivalent CDAMP or CVISC elements across the structural boundary points. Known Error

CR 7179

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Documentation - QRG - Inconsistent E,G, NU with MAT1

Description

Table 1 under the MAT1 description in the Version 68 MSC/NASTRAN Quick Reference Guide indicates that "E" and "NU" are used to define the properties for "Membrane and Bending" of the CQUADi, CTRIAi and CCONEAX elements. This should be clarified to state "should be clarified to "Membrane, Bending and Inplane Shear".

Known Error

CR 7182

Known Error

CR 7182

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Post Processing - SOL 103 and 105, OUTPUT2 - Missing Output When multiple subcases are used in SOL 103 or 105 and PARAM,POST,-1/-2 is chosen, the output2 file is written over with each subcase and only the last subcase remains in the output2 file for post processing. Avoidance: Request different output2 units in each subcase using param,ounit2 or the following DMAP alters may be used for some post processors (PATRAN3 v5)

Description

For SOL 103: COMPILE SUPER3 SOUIN=MSCSOU NOLIST NOREF $ ALTER 'IF ( POST=-1 AND OUNITX\OUN','IF ( ( ((DROPT=0 OR DROPT=4)' PARAML CASECC//'DTI'/1/1//S,N,SUBC1 $ PARAML CASEDR//'DTI'/1/1//S,N,SUBCNO $ IF ( POST=-1 AND SUBCNO=SUBC1 AND OUNITXOUNIT2 AND NOT(PEXIST) AND NOT((APP='NLST' OR APP='TRANRESP') AND PATVER>=3.) AND (((DROPT=0 OR DROPT=4) AND APP1'BKL1') OR APP='BKL0') ) OTAPE2=-1 $

Known Error

CR 7184

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Postprocessing - PARAM,OUGCORD,BASIC, PATVER,3 - Incorrect Deformed Shape PATRAN 3 will display an incorrect deformed shape when PARAM OUGCORD is set to BASIC and the gridpoint output coordinate systems (field 7, CD) is anything other than the basic (coordinate system ID 0). SubDMAP SEDRCVR transforms the displacement vector into the basic coordinate system based on the value of the parameter OUGCORD and PATVER. In Version 67.5 the DMAP IF test includes the value of the parameter PATVER which prevents transformation if PATVER=3.0 (default for PATVER is 3.0). 66 ELSE IF ( NOT(PATVER>=3.) AND OUGCORD='BASIC' ) THEN $ 67 VECPLOT UGVS,BGPDP,EQEXINS,CSTMS,CASEDR,/UGVSB//0/1 $

Known Error

CR 7184 The reason for preventing this transformation is that PATRAN 3 understands the CD field for the GRID entry. In Version 68 the DMAP test for PATVER is not present: 70

Known Error

CR 7185

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

Response Spectra - SDR2 - Wrong Answers The response spectra summation process for the NRL and SRSS methods handle the CBAR and CBEAM elements differently. Both the NRL and SRSS methods involve taking the square root of the sum of the squares of the value of interest, in this case stress. For the BEAM element the summation is made for the combined bending and axial stress, while for the BAR element the bending and axial stress is summed independently to coincide with the BAR's output which prints the axial stress separately. This leads to incorrect results for the output of the maximum and minimum stress. Avoidance: The CBEAM element should be used for Response Spectra Analysis whenever stress results are desired.

Known Error

CR 7186

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Description

Documentation - INCLUDE - Include File Not Found The Installation and Operations manual Section 4.5 states that the default directory for an include file is the input file's directory. The default directory is actually the current directory. Avoidance: Place the file to be included in the current directory or specify the complete path name of the file to be included.

Known Error

CR 7191

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Optimization/Design Sensitivity - TEMP(LOAD), TEMP(MATERIAL), SHPCAS -

Known Error

CR 7191 SFM 3001 When a TEMP(LOAD) and/or TEMP(MATERIAL) entry is used in the primary Subcase Control section of a shape optimization job using the analytic shape boundary shape approach in MSC/NASTRAN Version 68.2, the job will fail in module SHPCAS with the message "SYSTEM FATAL MESSAGE 3001". Avoidance: Apply the following DMAP alter.

Description compile bndshp nolist noref souin=mscsou alter 'auxmid'(2) dbview ugx=ug (where mtemp=*) $ alter 'partn','partn' PARTN UGx,,AXMVEC/UGA,,,/1 $ alter 'equivx','equivx' EQUIVX UGx/UGA/ALWAYS $

Known Error

CR 7193

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Description

Miscellaneous - Wrong continuation format - UFM 313 or Wrong Answers If column 1 of the continuation entry is blank, then the continuation entry is interpreted as a continuation of the last sorted bulk data entry. The error is likely to result in USER FATAL MESSAGE 313 ILLEGAL NUMBER OF WORDS ON CONTINUATION" or in rare cases possibly even wrong answers. An example follows: . Begin Bulk . . tic,100,101,1,0.,0. $ grid,1000,,0.,2.5,2.5 $ grid,101,,0.,0.,0. grid,102,,10.,0.,0. $23456789 10 cbar 1 1 101 102 1000 +000015 +000015 0.25 0. 0. 0.25 0. 0.

Known Error

CR 7193 $ . . enddata

will be interpreted as

BEGIN BULK . . CBAR 1 1 101 102 1000 +000015 . GRID 1 Known Error

CR 7196

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Miscellaneous - GP2, GENEL - Poor Message, SFM 3003 When at least one entire line is missing from a GENEL element, GP2 issues the message:

Description

SFM 3003 ATTEMPT TO READ PAST THE END OF A LOGICAL RECORD IN DATA BLOCK GEOM2S (FILE 101) IN SUBROUTINE GP2. Avoidance: Correct any offending GENEL elements. At a minimum the Reference Manual documentation should cite incorrect GENEL input as a possible cause of the error message.

Known Error

CR 7199

Product

MSC / MD Nastran

Corrected Version Abstract

Nonlinear Transient Analysis - PARAM,LGDISP - Poor Answers

Description

In MSC/NASTRAN Version 68 nonlinear transient analysis, solutions 99 and 129, were improved to correct error 2665 which stated that in nonlinear transient analysis the damping matrix is not updated. The damping forces for the large displacement solution now use the current "updated" damping matrix, which may have been calculated at an unconverged solution. This approach was intended to provide better directionality to the damping forces

Known Error

CR 7199 when they rotate. However, every time the damping matrix is updated for convergence, a change will occur in the force balance which will cause an erroneous step in the converged accelerations.

Known Error

CR 7201

Product

MSC / MD Nastran

Corrected Version 70 Abstract

Description

Element - CELASi - Forces/Stresses are Calculated in Single Precision Scalar spring and damper element's (ELASi and DAMPi, 1=1,2..4) stress and force outputs are calculated with only single-precision arithmetic. If a scalar element connects two points with small differences in displacements, relative to the total displacements, some numerical roundoff will occur. Since the stiffness and damping matrices are calculated in double precision the overall results will not be affected. The problem also does not occur on large-word, 64-bit computers such as CRAY and NEC. Avoidance: More precise results for the ELASi elements may be obtained from the GPFORCE output request.

Known Error

CR 7202

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Case Control - MPCFORCE=NONE - Extra Output ›The mpcf=none command does not turn off mpcforce output in a subcase when it has been requested above the subcase level. Avoidance: Define set 1 = [x], where x is a nonexistent grid or scalar point and use mpcf=1 instead.

Known Error

CR 7206

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Heat Transfer Analysis - CHBDYE,TUBE PHBDY - Wrong Answers The convection area used by the CHBDYE for the structure TUBE element is incorrect whenever D2 is left blank. In Version 69 the code is changed so that if D2 is left blank then D2 is set to D1. Avoidance: Use CHBDYP,TUBE option to represent the tube convection area or explicitly set D2.

Known Error

CR 7207

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Restart - SPCFORCE - Missing Output SPC force output request is ignored during automatic restarts in dynamic structured solution sequences. See related Error 3119 which was fixed for SOL 101 only. Avoidance: Include the entry PARAM, SERST, SEDR in the bulk data section of the restart deck.

Known Error

CR 7210

Product

MSC / MD Nastran

Corrected Version R70 Abstract

Security - NAO, NAOOPT - Job Hangs If the NAOOPT=INFO,MSG2 keyword is used with MSC/NAO Version 2 on the DEC ALPHA OSF/1 release of MSC/NASTRAN, the job will hang.

Description Avoidance: Remove the NAOOPT keyword from the nast682rc file or do not use it on the command line. Known Error

CR 7215

Product

MSC / MD Nastran

Corrected Version Abstract

Description

Cyclic Symmetry - SECSET1, VAXW, GIV, MGIV - UWM 3034, UFM 4645 Massless degrees of freedom that are placed in the c-set are not properly removed before entering the READ Module in Cyclic Symmetry component mode synthesis. Attempts to remove these degrees of freedom by explicitly constraining them will also be ignored. This may lead to "USER WARNING MESSAGE 3034, ORTHOGONALITY TEST FAILED" followed by a fatal message, "USER FATAL MESSAGE 4645---- THE SHIFTED STIFFNESS MATRIX IS NOT POSITIVE DEFINITE IN MGIVENS METHOD" or "USER FATAL MESSAGE 4646---- THE MASS MATRIX IS NOT POSITIVE DEFINITE, USING THE GIVENS METHOD. USE MGIV INSTEAD". Avoidance: Do not put the degrees of freedom in the c-set, specify Lanczos instead of a transformation method or add a small amount of mass to the massless degrees of freedom.

Known Error

CR 7219

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Miscellaneous - IFP - Infinite CPU Loop The following continuation entries while legal when using the NASTRAN MESH option result in an infinite cpu loop in IFP when the NASTRAN MESH command is removed.

Description

SPC1 10 10 11 = *1 *-1 *1 DESVAR 20 ABC 1. =2 *1 = *1. Avoidance: Add the NASTRAN MESH command or correct the continuation entries in error.

Known Error

CR 7220

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Postprocessing - PARAM,POST - Missing Output

Description

If the ASSIGN statement is not used or if the complete path is not specified on the ASSIGN statement for an OUTPUT2 file on the Windows NT Version of MSC/NASTRAN, the file is not written to the jid directory but is instead written to the "bin" directory. Avoidance: Specify a complete path on the ASSIGN statement.

Known Error

CR 7231

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Optimization/Design Sensitivity - XSORT - Incomplete Sorted Output The XSORT Module may encounter errors for large input files, when it is executed more than once during a run. The messages encountered are various, but the sorted file will be incomplete in every case. The error occurs only on large files, and only on the second and subsequent bulk data files. The errors occur when the bulk data to be sorted does not fit into memory. In Version 68 this error occurs only in design optimization analysis. Avoidance: Increase the memory request so that the file will fit into

Known Error

CR 7231 memory, or reduce the size of the file.

Known Error

CR 7232

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Miscellaneous - IFP, RBEi- UFM 4276 EC 7777 When the RBE3 bulk data entries contains illegal data in the REFC field, USER FATAL MESSAGE 316 should be issued to identify the offending entry. USER FATAL MESSAGE 4276 ERROR CODE 7777 is issued instead, which does not identify the illegal data. Avoidance: Other than locating the input in error and correcting it, there is no avoidance.

Known Error

CR 7233

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Matrix Methods - FBS, MPYAD - UFM 4547 FBS may set the density of GOAT incorrectly for some large models. The density should be between 0 and 10000 (i.e., 100%). However, it sometimes overflows this field and is printed in the f04 as *******. In this case the run will fail in the MPYAD module with the message "USER FATAL MESSAGE 4547"

Description Avoidance: Use the following alter to re-set the trailer to a value of 80% (or any value they desire). compile sekr, souin=mscsou, nolist, noref alter 106 $ the line which creates GOAT in his run modtrl goat///////8000 $ Known Error

CR 7234

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Loads - PLOAD1 - Missing Documentation, Unexpected Answers If on the TYPE field of the PLOAD1 entry, the element coordinate system direction (e.g. TYPE=FYE) option is selected, then the projection (i.e. SCALE=FRPR or LEPR) option is ignored and the result is the same as the SCALE=FR (or LE) option.

Known Error

CR 7234 Avoidance: There is no avoidance.

Known Error

CR 7237

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Description

Documentation - DMAP Module Dictionary, OUTPUT2, INPUTT2 - SFE 4276 EC 1401 MSC/NASTRAN Version 68 may not be able to handle an OUTPUT2 file of a matrix generated from an external client written computer program that follows MSC's documentation description of proper OUTPUT2 format. It is not the INPUTT2 step that is crashing, it is any subsequent operation on the datablock, such as TABPT, OUTPUT4, ADD, MATPRN or the like. Avoidance: Use V67.5 to convert the OUTPUT2 file to an OUTPUT4, and then read in the OUTPUT4 file into V68.

Known Error

CR 7238

Product

MSC / MD Nastran

Corrected Version 69 Abstract

p-Elements - DATAREC, OUTPUT - UWM 6514 (SDRPOP) When there are any OUTPUT bulk data entries, but no DATAREC case control keywords, the following warning is produced:

Description

*** USER WARNING MESSAGE 6514 (SDRPOP) THE DATAREC= 0 CASE CONTROL COMMAND REFERENCES UNDEFINED OUTPUT BULK DATA ENTRY. USER INFORMATION: THE DATAREC COMMAND WILL BE IGNORED. USER INFORMATION: THERE WILL BE NO ERROR-ESTIMATE OUTPUT FOR THE ADAPTIVITY ANALYSIS. Avoidance: To avoid the warnings, the OUTPUT entries should be removed.

Known Error

CR 7242

Product

MSC / MD Nastran

Corrected Version Abstract

p-Elements - GMCORD - Inefficient Processing

Known Error

Description

CR 7242 If a GMCORD coordinate system is used for the material, load, or displacement coordinate system, execution may be inefficient since the coordinate system is processed independently for each integration point. Avoidance: Other than not using GMCORDs there is no avoidance.

Known Error

CR 7243

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Description

Documentation - TABPT, BGPDTS - DMAP Module Dictionary According to the DMAP module dictionary "TABPT may occasionally misidentify real numbers or character values on the IBM/MVS-like computers". This problem is not limited to the IBM/MVS-like computers. Avoidance: Use TABPRT instead of TABPT.

Known Error

CR 7244

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Optimization/Design Sensitivity - ANALYSIS=FLUTTER, DMIG - Wrong Answers For flutter design sensitivity and optimization, the sensitivity results will be in error if there are multiple subcases and a second or subsequent subcase includes a different M2PP, K2PP or B2PP request in the case control. The sensitivity analysis is based on the generalized matrices from the first subcase and will therefore be incorrect for the subsequent subcases. Avoidance: There is no avoidance.

Known Error

CR 7253

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Nonlinear Analysis - MPCFORCE - Missing Output MPCforces are not output in nonlinear analysis, solution 106.

Description

Avoidance: Insert the following DMAP alter in Version 68.2: compile nlstatic

Known Error

CR 7253 alter 'ADD DELCVECT,CVECT0'(,-1) add5 qqgni,qgni,,,/qmgni//-1. $ call dbstore qmgni,,,,//nloop/0/' '/0 $ alter 'DBVIEW CVECTH' call dbfetch /qmgni,,,,/solcuri/0/0/0/0 $ call dbstore qmgni,,,,//solcur/0/' '/0 $ alter 'APPEND QGNI,/QGNR' $ file qmgni=ovrwrt $ $ call dbfetch /qmgni,,,,/nloop/0/0/0/0 $ file qmgnr=append $ APPEND QmGNI,/QmGNR/2 $ APPEND MPC FORCE VECTORS alter 'EQUIVX QGNR/QGN' call dbstore qmgnr,,,,//0/0/' '/0 $ compile super3 alter 'ADD PG,PJ/DPJ' call dbfetch /qmgnr,,,,/0/0/0/0/0 $ equivx qmgnr/qmg/-1 $ COMPILE SEDISP ALTER 'MPYAD PSS,CRX'(2) MPYAD PG,CRX,/PGX $ $

Known Error

CR 7260

Product

MSC / MD Nastran

Corrected Version 69.1 Abstract

Description

Nonlinear Transient Heat Transfer - DELAY, CHBDY - Incorrect Load Output If the DELAY bulk data entry is used to define an offset in time for the applied load. The actual heat load is applied correctly, and the resultant temperature value is correct. However in the data recovery for the heat flux of the HBDY element the load is applied incorrectly. Avoidance: Ignore the applied load output for the HBDY elements.

Known Error

CR 7266

Product

MSC / MD Nastran

Corrected Version 69 Abstract

DMAP - MALTER - Extra output

Description

The MALTER statement produces a listing of the altered subDMAP. This printout cannot be suppressed even if COMPILER NOLIST is specified. However, COMPILER REF and COMPILER

Known Error

CR 7266 DECK produce the correct results. Avoidance: There is no avoidance.

Known Error

CR 7270

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Acoustic Analysis - PARAM,WTMASS - Wrong Answers PARAM,WTMASS is applied to both the fluid and the structure, even though the mass of the fluid is in different units. Avoidance: a. use mass density for density values and ensure that all mass input values are in mass units. b. or insert the following DMAP alter in V68.2:

Description

compile semg noref nolist alter 'MJJX,/-1/WTMASS','' $ type parm,,cs,n,cwtmass,mwtmass $ IF (NOMGG>=0) then $ dbstatus VGFS//S,N,NOVGFS $ IF ( NOVGFS>0 and wtmass1.0 ) THEN $ EMA GPECT,MDICT,MELM,BGPDTS,SILS,CSTMS,MDICTP,MELMP/ MJJX1,/-1 $ MASS matgen ,/ig/6/lusets/0/lusets $ gx1 matrix cwtmass=cmplx(wtmass) $ add ig,vgfs/wtmass/cwtmass//3 $ matmod wtmass,,,,,/wtmassg,/28 $ gxg mpyad mjjx1,wtmassg,/mjjx $ ELSE $ EMA

Known Error

CR 7276

Product

MSC / MD Nastran

Corrected Version Abstract

Composites - PARAM,NOCOMP - Inconsistent Stresses

Description

Homogeneous stresses, output when using 0 or -1 for PARAM,NOCOMPS, for PCOMP-based elements are calculated inconsistently between linear and non-linear solutions. Since homogeneous stresses are based upon smeared laminate properties,

Known Error

CR 7276 both calculations yield only approximate the lamina stresses (see also current error list number 1818) but both solutions should use the same method. The two methods currently being used are: For linear analysis: S(z) = G1 * E - z * G2 * C (1) while for nonlinear analysis: S(z) = G1 * ( E - z * C ) (2) where: C = curvature (chi) E = reference plane strain (epsilon) G = modulus matrix S = stress z = distance from reference plane

Known Error

CR 7284

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Miscellaneous - DIAG - DIAGs Out of Range Not Checked

Description

I don't think this needs to be an external error report. Please read text below for error.

Known Error

CR 7288

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Nonlinear Buckling - MPC, RBE*, RBAR - Wrong Answers If MPC's or rigid elements are used in a nonlinear buckling analysis, then there is an error in the nonlinear buckling load factor (alpha computed by DMAP in SOL 66 or 106). This error causes the critical buckling factor (UIM 9040) to be estimated incorrectly. The remainder of the solution (eigenvalues and displacements) is OK. Avoidance: Use the following DMAP alter: compile nlstatic noref nolist $ alter 'MPYAD DULV,DPL0,/NUM3/1','' $ mpyad dugni,dpgni,/num3/1 $

Known Error

CR 7289

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Optimization/Design Sensitivity - CELASi, TEMP(LOAD), SSG1 - UFM 3032 USER FATAL MESSAGE 3032 may occur in optimization solution sequence when temperature loads are selected. The error will occur when the following three conditions are true: 1) A structural model contains scalar elements such as CELAS1. 2) The grid points connected to these scalar elements are subjected to a temperature load. 3) Only these scalar elements are designed and no other structural elements are designed.

Description

Note that scalar elements do not support temperature loading. Avoidance: 1) Make a dummy design variable and related it to a non scalar structural element in the model. Then impose the same lower and upper limits on the dummy design variables. 2) Replace the scalar elements with non scalar elements, i.e., use CROD instead of CELAS1.

Known Error

CR 7291

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Eigenvalue Analysis - REIGL, EIGRL - Poor Performance,

Description

The REIGL module, when solving for normal modes of a vibration problem, under certain rare circumstances will perform many negative shifts and ultimately fail to find the modes requested by the user. Although one negative shift often proves useful in picking up rigid body modes, additional negative shifts are unnecessary and wasteful of computer resources. One way to duplicate the problem is to specify on the EIGRL card, F1=blank, F2=very large, ND=blank. If the F2 value is several orders of magnitude greater than the largest eigenvalue in the model, the shift logic will usually fail with the multiple negative shifts.

Known Error

CR 7294

Known Error

CR 7294

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Miscellaneous - SUPORT1 - UFM 316 If a value of 0 (zero) is entered for the component number on a SUPORT1 entry USER FATAL MESSAGE 316 will result. › USER FATAL MESSAGE 316 (IFPDRV) ILLEGAL DATA ON BULK DATA CARD SUPORT1 *** Avoidance: If you are referencing SPOINTs on the SUPORT1 entry, then use 1 (one) or blank.

Known Error

CR 7295

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Documentation - SYSTEM(196), SCRSAVE - No Documentation on Lanczos System Cell

Description

There is no documentation in the Quick Reference Guide on the use of SYSTEM(196) (a.k.a. SCRSAVE). This system cell control reuse of scratch files when segment logic is invoked. System(196) is useful only when multiple frequency segments are requested on a Lanczos run. (Multiple frequency segments can be requested via the NUMS field in the EIGRL entry and by system(197).) Each frequency segment requires a minimum of three scratch files. When multiple frequency segments are used on a single processor computer then each frequency segment is solved serially. In this case, it makes sense to let segment #2 use the scratch files which were used by segment #1 since work for segment #1 has been completed (otherwise it wouldn't be working on #2). Similarly, when work for segment #2 is finish

Known Error

CR 7298

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Hyperelastic Elements - QUAD4, MATHP, PLPLANE - UFM 4297 Small hyperelastic QUAD4 elements may incorrectly fail with the message:

Description

USER FATAL MESSAGE 4297 (EQDGED) QUAD ELEMENT WITH ID = XX HAS AN INTERIOR ANGLE POSSIBLY GREATER THAN OR EQUAL TO 180 DEGREES. event though the geometry is actually good. The error is caused by a bad test on elements with lengths less than 1.0E-3.

Known Error

CR 7298 Avoidance: The only avoidance is to use different units to make the distances larger.

Known Error

CR 7300

Product

MSC / MD Nastran

Corrected Version Abstract

Nonlinear Analysis - CGAP - Poor Results If the adaptive GAP element indicates an update of an element stiffness AFTER the program has converged on a solution, the program FAILS to reiterate upon that newly updated stiffness matrix hence the results are based upon the GAP stiffness prior to the update. This error has been encountered when the adaptive GAP gets the following message:

Description

*** NEW STIFFNESS MATRIX IS REQUIRED BY GAP FOR PENALTY VALUE ADJUSTMENT *** PENALTY VALUES ARE ADJUSTED BY YYY FOR ELID = xx AFTER the program has converged on the solution. Avoidance: Increase the number of increments, NINC on the nlparm entry, or adjust the value of the stiffness on the offending PGAP or both.

Known Error

CR 7305

Product

MSC / MD Nastran

Corrected Version 70 Abstract

Documentation - OTIME - Extra Output, OTIME Not Effective in Nonlinear Transient

Description

The OTIME case control command is used to limit output in transient analysis. This command is not effective for nonlinear transient stress output.

Known Error

CR 7306

Product

MSC / MD Nastran

Corrected Version 70 Abstract

Online Documentation - Common Questions and Answers

Description

The line "NASTRAN SCRATCH(MEM=n)" on page 267 of MSC/NASTRAN Common Questions

Known Error

CR 7306 and Answers (Second Edition) in the MSC/NASTRAN Encyclopedia, page 144 in the printed text, should be: "INIT SCRATCH(MEM=n)"

Known Error

CR 7307

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Dynamic Analysis - UWM 4684 LOADSET ID NOT FOUND In a dynamic response analysis, when the bulk data contains LOAD entries that are not referenced by the CASE control and if STRESS output is requested, then the following warning message is issued.

Description USER WARNING MESSAGE NUMBER 4684 LOADSET ID NOT FOUND FOR SUBCASE 1 Avoidance: Remove the non referenced LOAD entries from the bulk data. Known Error

CR 7312

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Optimization/Design Sensitivity - DOM11, GEOM1 - SFM 3001 When only scalar points (no GRID entries) are defined in an optimization model and the SEQP module is not executed to resequence the model, then there is no GEOM1 generated. The run subsequently fails in the DOM11 module when it tries to make a copy of GEOM1 with the message "SYSTEM FATAL MESSAGE 3001 MODULE = DOM11 GEOM1 AT POSITION 12 DOES NOT EXIST". Avoidance : Include a dummy GRID entry.

Known Error

CR 7314

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Performance - VECPLOT - Poor Performance On problems with more than 65,000 dofs, the vecplot module is inefficient, and may cost as much as the rest of the calculations. It is used in several places, primarily as a means of providing checks such as applied load resultants. Avoidance: If you observe that the amount of time being spent in this

Known Error

CR 7314 module is excessive you may insert an alter to delete this module call. The alter for all Version 68.2 structured solutions is: compile selg nolist noref $ alter 63,63 $

Known Error

CR 7320

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Heat Transfer Analysis - CHBDYE, VIEW - SFM 3007 The message "SYSTEM FATAL MESSAGE 3007 MODULE=VIEW, ILLEGAL INPUT TO SUBROUTINE VNASIN" will occur if using the backside on the CHBDYP LINE element, for example:

Description

CHBDYP 101 11 LINE 111 2 3 + + 1111 0 -1.0 1.0 0.0

Avodiance: Specifying the VIEWID on the frontside resolves this problem. Known Error

CR 7326

Product

MSC / MD Nastran

Corrected Version 70 Abstract

Documentation - FORCE(PLOT) - Missing Documentation

Description

The MSC/NASTRAN Quick Reference Guide does not document the FORCE command (PLOT) option. This option may be used if element force calculations are desired for post-processing without printing them.

Known Error

CR 7333

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Frequency Response and Random Analysis - TETRA, PSDF - UFM 3052 Random response analysis that requests PSDF xyplots of TETRA stress results may result in the following fatal message:

Description

USER WARNING MESSAGE 3052, A RANDOM REQUEST FOR CURVE TYPE STRE -, POINT -1 COMPONENT - 12 -, SPECIFIES TOO LARGE A COMPONENT ID. THE LAST COMPONENT WILL BE USED.

Known Error

CR 7333 The XYPLOT summary will then indicate that the correct plot is used, but wrong results will be presented on the XYPLOT summary. In fact, if 6 plots are selected, with items codes 6,7,8,9,10 and 11, the summary will say they all have the same RMS value, even though they are asking for normalx, normaly, normalz, tauxy, tauxz, and tauyz, which cannot be the same. Running a similar problem with a HEXA instead of TETRAs, produces good results.

Known Error

CR 7335

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Optimization/Design Sensitivity - PBEAM - Wrong Answers Errors occur in design optimization of beam elements if the following two conditions are met: 1.) The beam section is constant (e.g., end b data is not supplied on the PBEAM entry) and

Description

2.) End B data is referenced on a DVPREL1 entry. By not supplying end B data, the code is mislead to believe the section is constant, even if this is in conflict with information supplied in the design model. Avoidance: Supply end B data in the case of a tapered beam, and all necessary intermediate stations in the case of a variable beam section.

Known Error

CR 7338

Product

MSC / MD Nastran

Corrected Version 69 Abstract

SSSALTER - resflexa.v682 An error in the resflexa.v682 alter in sssalter directory may result in loadings applied to the residual structure not being included in the residual vector calculation.

Description Avoidance: Add the following line after the line containing 'type db,pss $'

Known Error

CR 7338 TYPE DB,PL

Known Error

CR 7339

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Nonlinear Transient Analysis - NLTRD2, ADAPT - SFM 4276 EC 1044 Nonlinear transient analysis fails in the module NLTRD2 with the message "SYSTEM FATAL ERROR 4276.OPEN ERROR CODE 1044". This error happens when the adapt method is used if

Description

1. There are no nonlinear elements in the model. 2. Stress output is requested. 3. The NO field of the TSTEPNL entry is greater than 2. Avoidance: Use the default (1) for NO field of the TSTEPNL entry.

Known Error

CR 7340

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

DMAP - LTU - SFM 3001

Description

User DMAP runs submitted with scr=yes may fail with SYSTEM FATAL MESSAGE 3001. This error may result if the LTU logic deletes a datablock even though it is still needed. Avoidance: Run the job using SCR=NO or create a copy of the datablock and use the copy in the DMAP alter.

Known Error

CR 7342

Product

MSC / MD Nastran

Corrected Version 70 Abstract

Optimization/Design Sensitivity - STATSUB - Wrong Answers Wrong buckling sensitivities may occur when the following conditions are true:

Description

1. DSNOKD is nonzero, 2. The Subcase Control command STATSUB does not refer to the first subcase and 3. The referred subcase does not have retained responses of its own. Avoidance: Define an artificial response with very large upper and lower limits and force retention of the response in the referred subcase using

Known Error

CR 7342 DRESP1, DCONSTR and DSCREEN entries.

Known Error

CR 7356

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

P-Elements - DATAREC - UFM 6352 If a model contains output requests for p-elements (i.e., a DATAREC and OUTPUT entry), but no p-elements are defined in the model, UFM 6352 may occur. Avoidance: Either create a p-element in the model or remove the p-element output requests.

Known Error

CR 7358

Product

MSC / MD Nastran

Corrected Version 69.1 Abstract

Installation - User Modifiable NASTRAN - CRAY C90 Only The CD for User Modifiable MSC/NASTRAN Version 68.2 contains errors in the unicos and unicosc90 directories. 1) The unicos*/undynamic* files are misnamed. They are renamed as follows:

Description

mv unicos/undynamic_7X.o unicos/undynamic_70.o mv unicos/undynamic_8X.o unicos/undynamic_80.o mv unicosc90/undynamic_7X.o unicosc90/undynamic_70.o mv unicosc90/undynamic_8X.o unicosc90/undynamic_80.o 2) The unicosc90/umnld script is incorrect. All references to "unicos" must be changed to "unicosc90".

Known Error

CR 7365

Product

MSC / MD Nastran

Corrected Version GL Abstract

Heat Transfer Analysis - VIEW3D, CHBDYE - No VIEW Factor Calculation

Description

The CHBDYE element references the conduction element for the geometry. If the user attempts to calculate the view factor exchange between two plates by using a line element such as a bar or rod and the CHBDYE element which references the rod element for the surface information, then no view factor

Known Error

CR 7365 calculation will be performed on the CHBDYE line element. . Avoidance: Use the CHBDYP,LINE to model the surfaces instead of the CHBDYE element.

Known Error

CR 7367

Product

MSC / MD Nastran

Corrected Version 70 Abstract

Description

Documentation - Design Sensitivity/Optimization, RBEi, MPC's, DVGRID UFM 6499 It is a limitation of MSC/NASTRAN, that the sensitivities are incorrect for shape optimization runs which have DVGRID entries which reference grid points on MPC or RBEi entries. Often, the sensitivities are 0.0 and therefore the following message is produced "ONE OR MORE VIOLATED CONSTRAINTS HAS A ZERO GRADIENT **** NO PROGRESS IS POSSIBLE. OPTIMIZATION TERMINATED *** USER FATAL MESSAGE 6499 (DOM9) THE DOT OPTIMIZATION ALGORITHM HAS ENCOUNTERED AN ERROR THAT MAKES FURTHER PROGRESS IMPOSSIBLE. SEE MESSAGES ABOVE". This limitation should be documented under the DVGRID entry. Avoidance: It may be possible to replace the RBEi or MPC relation with an element which has an extremely large stiffness.

Known Error

CR 7376

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Description

p-Elements - CORD3G - SFM 6333 (EQNINI) When a convective coordinate system (cord3g) is specified as a stress output coordinate system in OUTRCV, sdr2 crashes with BIOMSG: ERROR 211 HAS OCCURRED IN ROUTINE BLPK68 . Avoidance: Other than not referencing a cord3g entry, there is no avoidance.

Known Error

CR 7380

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Documentation - QUAD4, PARAM,S1M, PARAM,CURV,1 - User Output Coord. Systems

Known Error

CR 7380 QUAD4 corner stresses do not support output in a user defined coordinate system using PARAM,CURV,1 and PARAM,S1M,1 and a MCSID coordinate system on a MAT1 or MAT2 entry. The MAT1 and MAT2 Quick Reference guide documentation needs to be updated as follows: The MAT1 remark 7 needs to changed to:

Description

7. MCSID must be nonzero if PARAM,CURV is specified to calculate stresses or strains at grid points on plate and shell elements only. This feature does not support QUAD4 corner stresses. The MAT2 remark 6 needs to changed to: 6. MCSID must be nonzero if PARAM,CURV is specified to calculate stresses or strains at grid points. This feature does not support QUAD4 corner stresses.

Known Error

CR 7391

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Heat Transfer Analysis - RADCAV - SFM 4276, Infinite Loop In SOL 153, if global view factors are specified (i.e. the continuation entry on the RADCAV is used), then the run may go into an infinite loop or issue SYSTEM FATAL MESSAGE 4276 for some set definitions. Avoidance: Do not use global view factors or redefine which elements are contained in sets selected by the RADCAV entry.

Known Error

CR 7397

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Documentation - QRG, APP COUPLED - Incorrect Reference to Thermal User's Guide The MSC/NASTRAN Version 68 Quick reference guide makes the following refererence under the description of the APP Executive Control Command:

Description

APP COUPLED Indicates that a coupled analysis combining heat transfer and structural analysis in SOL 153. See the MSC/NASTRAN Thermal Analysis Users Guide. In fact there is no description of the coupled thermal analysis in the Version

Known Error

CR 7397 68 Thermal Analysis User's Guide.

Known Error

CR 7403

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Optimization - PCOMP - UFM in SDRCOMP, Corner Stress Request The presence of composites in SOL 200 when corner stresses are requested will cause the following unnumbered fatal message in the SDRCOMP module: USER FATAL MESSAGE. INCONSISTENT DATA DETECTED IN THE OES1A LAMINATE STRAIN AND OEF1A ELEMENT FORCE DATABLOCKS

Description

In V70.5 and later, an error message similar to the following may be output instead from the SDRCOMP module: *** SYSTEM FATAL ERROR 4276.GREAD ERROR CODE 3001 PID= 0 Avoidance: Remvoe the CORNER, BILIN, SGAGE or CUBIC option from your STRESS or FORCE output requests. However if noncomposite load responses are not used, the following DMAP alters will allow noncomposite corner stress responses and composite center stress and failure index responses to be used. But it will cause non-composite force responses to fail.

Known Error

CR 7404

Product

MSC / MD Nastran

Corrected Version 69 Abstract

p-elements - GP4 - SFM 3008, Insufficient Memory, Excessive Runtime When converting a large h-element model directly to a p-element model, the run may fail in GP4 with the following error messages:

Description

SYSTEM FATAL MESSAGE 3008 MODULE = GP4 0INSUFFICIENT MEMORY AVAILABLE FOR SUBROUTINE CSTRAN 0FATAL ERROR The runtime in GP4 will also be excessive. This error is most likely to occur when there are many grid points which reference non-basic output coordinate systems.

Known Error

CR 7404 Avoidance: Other than increasing the memory on the mem keyword, there is no other known avoidances. The amount of memory required for a large problem can be substantial in this case.

Known Error

CR 7409

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Heat Transfer Analysis - SOL 101 - SFM 4276. FREAD EC 3002 Solution 101 heat transfer (app heat) superelement runs will fail in solution 101 with the following message:

Description

SYSTEM FATAL ERROR 4276.FREAD ERROR CODE 3002 Avoidance: Other than no running superelements there is no avoidance.

Known Error

CR 7410

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Eigenvalue Analysis - EIGRL - Wrong Answers If the following EIGRL format EIGRL,SID,V1,,ND

Description

is used, and the first flexible mode is substantially higher than the rigid body modes, then modes below V1 may also be included in the eigenvalue table printout. Avoidance: Either increase V1 or include a shift scale that is close to the estimated first desired mode.

Known Error

CR 7414

Product

MSC / MD Nastran

Corrected Version GL Abstract

Optimization/Design Sensitivity - Poorly Labeled Output

Description

It is difficult to relate the output in solution 200 (DISPLACEMENT, STRESSES, SENSITIVITY, ETC ) to the design cycle. The output headers do not include the design cycle number for which the output is printed. Avoidance: Look for the "USER INFORMATION MESSAGE 9051" , which

Known Error

CR 7414 contains the design cycle information preceding the output.

Known Error

CR 7425

Product

MSC / MD Nastran

Corrected Version GL Abstract

DMAP - CALL - Incorrect PARAM Value Passed Back If a parameter is passed into a subDMAP on the CALL statement, it is possible that the program may pass a value of 0.0 back to the calling subDMAP for that parameter. This has only been observed if the following conditions are met:

Description

1) The parameter appears on the CALL statement without the 'S' feature 2) The parameter is defined as being able to be changed in the bulk data or case control ( 'Y' option on the TYPE statement in the called subDMAP') 3) The same name is used for the parameter in the calling and called subDMAPs 4) The value of the parameter is changed in the called subDMAP Avoidance: Change the name of the parameter in the called subDMAP or use the 'N' option on the TYPE statement in the called subDMAP.

Known Error

CR 7428

Product

MSC / MD Nastran

Corrected Version 70 Abstract

Documentation/Elements - CGAP, CORDCi, CORDSi - Wrong Answers

Description

If a cylindrical (CORD1C/CORD2C) or spherical (CORD1S/CORD2S) coordinate system is specified for a gap element (CID field of CGAP entry), and one of the connected GRIDS is defined at the center of that coordinate system, wrong answers result. Wrong answers result, even if the GRID at the center of the coordinate system is defined in a cartesian system. Avoidance: Displace the GRID at the center by as little as 1.E-40 in the direction of the desired gap axis, or define the v vector and leave the CID field blank.

Known Error

CR 7452

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Postprocessing - Optimization, TRANS - Missing Datablock CHISTM from xdb

Description

MSC/NASTRAN Version 68.2 on CRAY computers fails to write the CHISTM

Known Error

CR 7452 datablock to the .xdb file. An incorrect xdb will show the following when the resulting xdb file is written to neutral format with the TRANS utility:

. . DATA BLOCK PROJECT SE ID PATH SUBCASE SET ID APPROACH CHIST 1 0 1 0 0 0 CQD4 1 0 1 0 0 0 CQD4 1 0 1 0 0 0 CQD4 1 0 1 0 0 0 CTAB 1 0 1 0 0 0 CTAB2 1 0 1 0 0 0 DCYCT 1 0 1 0 Known Error

CR 7454

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Nonlinear Analysis - PLSOLID, PLPLANE, TEMP(LOAD) - SFM 4276, EC 7777 Hyperelastic elements with temperature loads do not work on MSC/NASTRAN Version 68 Alpha OSF/1 system. All jobs with temperature loads and hyperelastic elements will fail with the message "SYSTEM FATAL MESSAGE 4276, ERROR CODE 7777" in the NLITER Module. Avoidance: Other than running on another machine there is no avoidance.

Known Error

CR 7460

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

Optimization/Design Sensitivity - PCOMP, SUBCOM - SFM 3007 The message, "SYSTEM FATAL MESSAGE 3007 MODULE = DSAL" is produced if: (1)there are active DRESP1 responses associated with composites (CSTRESS,CSTRAIN,CFAILURE), (2) SUBCOM's are used and (3) One or more of the subcases used in the SUBCOM has no active responses. Avoidance: An avoidance is to add responses in the subcases referenced on the subcom and force their retention using DSCREEN.

Known Error

CR 7462

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Heat Transfer - CHBDYG, RADBC - Wrong Answers If a negative EID is specified on the RADBC entry to indicate that the boundary condition is to be applied to the back face of the element, then the load applied is incorrect and wrong answers result.

Description

Avoidance: Define another CHBDYG or CHBDYE on the backside and use it to apply the load.

Known Error

CR 7463

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Stress Discontinuities - STDCON - Inefficient Processing

Description

The STDCON module can be very inefficient. For some problems, enhancements in Version 70.5 have improved the performance of this module by several orders of magnitude.

Known Error

CR 7464

Product

MSC / MD Nastran

Corrected Version 69 Abstract

P-Elements - CQUAD8, CTRIA6 - SFM 6398 (GPOI) Preliminary edge table If there are h-element CQUAD8s and/or CTRIA6s next to p-elements, and there are midsides on the common edges, the following message may result: SYSTEM FATAL MESSAGE 6398, (GP0I), PRELIMINARY EDGE TABLE CREATED IN GP0B IS INVALID. USER ACTION: CONTACT CLIENT SUPPORT AT MSC.

Description

The error message should be more specific. The error is considered corrected in Version 69 by issuing the following message: USER FATAL MESSAGE 6544, (GP0I), THE EDGE WITH GRIDS ID = **, ** ON P-ELEMENT ID = ** IS SHARED BY AN H-ELEMENT WITH MID SIDE GRID.

Known Error

CR 7469

Product

MSC / MD Nastran

Corrected Version 2001.0.1 Abstract

Frequency Response Analysis - Random - SFM 4276 EC 3001, Poor Message In a random analysis, the J and K fields (fields 3 and 4) on the RANDPS entry should reference the subcase identification number, as documented in the Quick Reference Guide. However, if the J and K fields reference the subcase sequence number instead, the job will fail with the following unclear messages.

Description

BIOMSG: ERROR 3001 HAS OCCURRED IN ROUTINE FREAD , FILE INDEX (FILEX) =0 SYSTEM FATAL ERROR 4276.FREAD ERROR CODE 3001 PID= 0 Avoidance: Modify the J and K fields on the RANDPS entry to reference the appropriate subcase identification numbers.

Known Error

CR 7470

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Geometric Nonlinear Analysis - ELAS3, ELAS4 - Wrong Answers CELAS3 and CELAS4 elements produce wrong answers in SOL 64.

Description Avoidance: Use CELAS1 or CELAS2 elements. Known Error

CR 7476

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Heat Transfer - EMG, FTUBE, MATT4 - Quits in EMG

Description

If the data on the TABLEM1 referenced by a MATT4 entry is poorly defined such that the extrapolated viscosity versus temperature results in a negative viscosity (which is physically impossible) then the run fails without message in the EMG module. Avoidance: Make sure that the viscosity versus temperature curve always remains in the (+,+) quadrant.

Known Error

CR 7480

Product

MSC / MD Nastran

Corrected Version GL Abstract

DMAP - Delivery Database Build - SFE 4276 in XCSA

Known Error

Description

CR 7480 When building a delivery database in more than one run, if any subDMAP fails compilation in the first run, which also compiles the NDDL, then a subsequent run may fail with BIOMSG error 3001 in GREAD and SYSTEM FATAL MESSAGE 4276 in XCSA. Avoidance: If this message is encountered, the delivery database is corrupted and must be rebuilt. To avoid corrupting the database again, do not compile any subDMAPs in the first run.

Known Error

CR 7481

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

DMAP - Delivery Database Build - Poor Message, SFE 4276 in LINKER When building a delivery database in more than one run, if a subDMAP which is called by a main subDMAP fails during compilation in one run and then a link of the main subDMAP is attempted in the next run, then the run will fail with BIOMSG error 3001 in GREAD and SYSTEM FATAL MESSAGE 4276 in LINKER. The run should have failed with USER FATAL MESSAGE 443 or 444. Avoidance: Recompile the offending subDMAP and relink the main subDMAPs which call the offending subDMAP.

Known Error

CR 7495

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

P-elements - VIEWP, TETRA, FEEDGE - Excessive CPU For large models of TETRA p-elements with curved edges (i.e. FEEDGE bulk data entries), the VIEWP module takes excessive CPU time. The time spent in the VIEWP for TETRA p-elements with curved edges is approximately ten times a model that does not have curved edges. The overall run time may be increased approximately 30 percent. Avoidance: There is no avoidance.

Known Error

CR 7498

Product

MSC / MD Nastran

Known Error

CR 7498

Corrected Version 69 Abstract

Transient Heat Transfer - DPD - UFM 2066, 2079, SWM 2072 If the grid points are given TEMP for the initial conditions without the use of a TEMPD bulk data entry, then you the following error message is encountered:

Description

USER FATAL MESSAGE 2079, GRID OR SCALAR POINT ******** HAS AN UNDEFINED COORDINATE REFERENCED ON A NOLINI CARD. USER FATAL MESSAGE 2066, UNDEFINED GRID POINT 0 ON DAREA-, RLOADOR TLOAD- CARD. SYSTEM WARNING MESSAGE 2072, CARD TYPE 7107 NOT FOUND ON DATA BLOCK. Avoidance: Add a TEMPD bulk data entry.

Known Error

CR 7511

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Eigenvalue Analysis - REIGL, EIGRL - Wrong Answers In rare cases Lanczos may produce wrong answers and no warning message is issued. MSC/NASTRAN Version 69 corrects this situation by issuing appropriate messages.

Description

Avoidance: Prior to Version 69, it is the user's responsibility to verify that the actual eigenvalues found agree with all sturm checks. If the results do not agree then they can not be correct. The eigrl entry should be modified by increasing maxset to 15 from the default of seven and the job should be re-run. Changing the frequency range of interest such that f1 is blank, not 0.0, often corrects the problem.

Known Error

CR 7513

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Description

Optimization/Design Sensitivity - DOM6, DRESP2, PARAM,OPTEXIT - SFM 3001 When only DRESP2 responses are defined in an optimization job, the requested OPTEXIT=4 or -4 results in two different errors: 1. In Version 68.x, SYSTEM FATAL MESSAGE 3001 occurs in DOM6.

Known Error

CR 7513 2. In Versions 69 and 70, the DSCM2 matrix is not generated in an f06 file. Avoidance: There is no avoidance for v68.x. A dmap avoidance is available for v69 and v70: compile exitopt alter 'if ( ((','if ( ((' if ( ((dsprint or dsunform or dsexport) and mdtrkflg=0) and (NORSP2>0 or nodscmg>0) ) THEN $ endalter

Known Error

CR 7515

Product

MSC / MD Nastran

Corrected Version 69.0.4 Abstract

Direct Transient Analysis - CBAR,PLOAD1,LOADSET/LSEQ - Wrong Answers In a direct transient dynamic analysis, if a CBAR element is loaded by a PLOAD1 entry through the LOADSET/LSEQ combination, then the output titled "force distribution in bar elements" will be wrong. Avoidance: There are two possible avoidances:

Description 1. Replace the CBAR element with a CBEAM element. 2. Replace the PLOAD1/LOADSET/LSEQ combination with equivalent point loads using the DLOAD/TLOADi/DAREA combination. Known Error

CR 7518

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Post-processing - PARAM,POST,-5, PARAM,OUGCORD,BASIC - Missing Output If PARAM,POST,-5 is specified with PARAM,OUGCORD,BASIC then PARAM,POST,-5 is effectively ignored and the expected output will be missing.

Description

Avoidance: Insert following DMAP alter: compile sedrcvr alter 'ELSE IF ( NOT(post',''

Known Error

CR 7518 ELSE IF ( post>-3 and PATVER 0 or Character = "ALL")

Description to SEIDB Superelement identification. (Integer >= 0 or Character = "ALL")

Known Error

CR 29922

Product

MSC / MD Nastran

Known Error

CR 29922

Corrected Version GL Abstract

Rigid Elements - RSSCON, SECNSD - UFM 6692 When a highly skewed plate element is attached to a solid element with an RSSCON entry, the run may fail with the message:

Description

*** USER FATAL MESSAGE 6692 (SECNSD ) RSSCON NUMBER *** CANNOT CONNECT AN EDGE OF QUAD ELEMENT *** TO HEXA ELEMENT *** Avoidance: The only avoidance is to reduce the skewness of the plate element or to use the GRID option on the RSSCON entry.

Known Error

CR 29932

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Installation - MSC/NASTRAN will not run on SGI IRIX 6.4 MSC/NASTRAN V68.2.3 (r2) for the SGI R8K may not run on IRIX 6.4 or later systems. The failure will occur at program start, before any processing has begun, with the following message:

Description

MSC/NASTRAN started Mon Nov 17 08:45:14 PST 1997 Process Id = 27828 idalloc: address of dynamic common is too low current brk value: 0x12700000 ( 309329920) current address of XNSTRN: 0x121f0000 ( 304021504) ***memory allocation failed, program stop*** real 0m0.04s user 0m0.02s sys 0m0.02s MSC/NASTRAN finished Mon Nov 17 08:45:14 PST 1997 The specific reason is that the amount of code and data put into the user's address space by the runtime libraries and OS has become too large and interferes with MSC/NASTRAN

Known Error

CR 29944

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Static Aeroelastic Analysis - QSETi, SEQSETi - UWM 5229, SFMs 2198, 2199, 3007

Known Error

CR 29944 If QSETi entries are present in SOL 144, Static Aeroelastic Analysis, the run will fail in subDMAP AESTATRS. The message issued from subDMAP AESTATRS varies. If the a-set contains only q-set dofs, the following messages are issued: *** USER WARNING MESSAGE 5229 (DDCOMP) INPUT FILE TO MODULE DECOMP PURGED. MODULE RETURNS WITH PURGED OUTPUT. *** SYSTEM FATAL MESSAGE 2198 MODULE = FBS INPUT DATA BLOCK 101 HAS BEEN PURGED.

Description *** SYSTEM FATAL MESSAGE 2199 MODULE = FBS SUMMARY, ONE OR MORE OF THE ABOVE FATAL ERRORS WAS ENCOUNTERED IN SUBROUTINE DFBS . If the a-set contains q-set and t-set dofs the the following message are issued: *** SYSTEM FATAL MESSAGE 3007 (UMERGE) ILLEGAL INPUT TO SUBROUTINE MERGE QSETi and SEQSETi entries Known Error

CR 29965

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

DBC - SWM 6065 - Undocumented Limit in DBC, SWM 6065 (DBC) The DBC module always has had a limit of 9999 allowable output positions available for any process list, ie time, frequency, modes, etc. The enforcement of this limitation has not always been consistent until V70. This limit may lead to the message:

Description

^^^ SYSTEM WARNING MESSAGE 6065 (DBC) ^^^ DBCMSG ERROR MESSAGE 43 FROM SUBROUTINE DBCAOL OUTPUT LIST SUPPLIED EXCEEDS INTERNAL LIMIT, SUPPLIED 20013 INTERNAL LIMIT 10000. Version 70.5 uses a new dynamic access key technique which effectively increases the limit for many problems. MSC/XL and other programs may no be compatible

Known Error

CR 29965 with this new technique. SYSTEM(274)=1 (a.k.a. DBFACT=1) is provided to access the old technique. This system cell may be set in the system or user rc file as well as the individual test deck.

Known Error

CR 29998

Product

MSC / MD Nastran

Corrected Version 70.5.2 Abstract

Matrix Methods - MPYAD METHOD 4T - UFM 4276 EC -31 Certain problems cause MPYAD METHOD 4T to be selected when other methods would solve the problem much more efficiently. The problem will take longer to run than it should and may run out of disk space. The symptom of the bad method selection is that MPYAD METHOD 4 T is selected with a large number of passes. This can be seen in the f04 file, for instance, as follows:

Description 20:36:57 267:07 53987.9 626.3# 6843.0 188.9# FDRMGEN MPYAD END 20:36:58 267:08 53998.1 0.5 6843.1 0.0 FREQRS 15 MPYAD BEGN METHOD 4 T , NBR PASSES=****, EST. CPU= 81.7, I/O= 40.0, TOTAL= 121.8 20:36:58 267:08 53998.1 0.0 6843.1 0.0 MPYAD BGN P=2930 20:36:58 267:08 53998.9 0.8 6843.2 Known Error

CR 30005

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

External Superelement - ASETi, SE - SEP1X, SFM 3007 In an external superelement generation run, if the DMIGPCH option is used with the ASETi entries, and the external superelement contains upstream superelements, then the punch file will not contain the physical boundary matrices. The job may also fail with SFM 3007.

Description

Avoidance: There are two possible avoidances: 1. Use BSETi instead of ASETi entries to represent the boundary points. 2. Use the DMIGDB, DMIGOP2, or MATRIXDB option instead of the DMIGPCH option.

Known Error

CR 30007

Product

MSC / MD Nastran

Known Error

CR 30007

Corrected Version Abstract

Documentation/Nonlinear Analysis - Multiple Subcases, Different Answers

Description

A transient nonlinear analysis may yield slightly different results when the problem is defined with multiple subcases rather than a single subcase. The difference occurs because loads are averaged over three timesteps. The loads at the end of a subcase and the beginning of the subsequent subcase may then be slightly different.

Known Error

CR 30009

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Installation - SIGNAL 11 (SIGSEGV) CODE 5, or CODE 6 The submittal script on MSC/NASTRAN Version 70 on Convex computers has an error which may cause jobs that request more than 10 million words of memory to fail with the message:

Description

***** RECEIVED SIGNAL 11 - Segmentation fault (SIGSEGV); CODE 5 - Invalid page table reference (SEG_INVPTP_TRAP) JOB ABORTING... Avoidance: Modify the nast70.lcl file in the msc70/bin directory as follows: %MSC_ARCH=convex:% $tcmd %a.solver% $asgf %mem% rather than %MSC_ARCH=convex:% $tcmd %a.solver% %a.rel=68:% $asgf %mem%

Known Error

CR 30010

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Superelements - BEGIN BULK SUPER, RESTART - SFM 3001 A restart of a superelement problem will result in the fatal message shown below, if the cold start contains superelements defined in the main bulk data section as well as other superelements defined in the partitioned bulk data sections.

Description

*** SYSTEM FATAL MESSAGE 3001 (SEP1X ) THE EXECUTIVE FILE 0 DOES NOT EXIST. PROGRAMMER INFORMATION: SUBROUTINE SEPMAB Avoidance: Define all superelements in either the main bulk data section or the partitioned bulk data section, but not both.

Known Error

CR 30011

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Optimization/Design Sensitivity - MFREQ, OFREQ - SFM 4276.GREAD EC 3001 If a multidisciplanary optimization run uses MFREQ as one of the disciplines, contains an OFREQ Case Control requests and has a value of P2>=8 on the DOPTPRM entry to indicate that the responses are to be printed, then the job will fail with the following fatal message in the DOM10 Module:

Description

SYSTEM FATAL ERROR 4276.GREAD ERROR CODE 3001 PID= 0 USER INFORMATION MESSAGE: TO OBTAIN A NASTRAN DUMP, RESUBMIT JOB WITH DIAG 44 INSERTED IN THE EXECUTIVE CONTROL SECTION. Avoidance: Remove the OFREQ request or lower the value of P2 on the DOPTPRM entry.

Known Error

CR 30015

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Description

ESTIMATE - Incorrect estimates of DOF on TRIAX6 elements. The ESTIMATE utility may incorrectly count the degrees of freedom associated with CTRIAX6 elements. If the singular degrees of freedom are explicitly constrained, either on spc entries, grid entries or grdset entries, then the ESTIMATE will assume that a constraint in the 2 degree of freedom is removing one of physical degrees of freedom. This is not correct as a CTRIAX element is define in the x-z plane not the x-y plane. As a result, ESTIMATE will undercount the DOF by one per CTRIAX6 element. Avoidance: Do not explicitly constrain the singular degrees of freedom, let autospc perform this function.

Known Error

CR 30020

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Matrix Methods - MPYAD 2 or 3 - Wrong Answers

Description

When very low memory is requested such that MPYAD method 2 or 3 are selected, and multiple passes are required, then the job will produce wrong answers. Insufficient memory causes the sparse method to be deselected and MPYAD METHODs 2 and 3 to spill in multiple passes. This information is contained in the f04 file with DIAG 19.

Known Error

CR 30020 Avoidance: Deselect method 2 and 3 by adding the following system cell to the top of the input file or system rc file: nastran system(66)=60 This may cause some jobs that require methods 2 or 3 to fail with the message: *** SYSTEM FATAL MESSAGE 3001 (*** ) THE SCRATCH FILE 399 DOES NOT EXIST. PROGRAMMER INFORMATION: SUBROUTINE GOPEN 0FATAL ERROR The most likely jobs to encounter this message are optimization jobs in DOPR1. If

Known Error

CR 30023

Product

MSC / MD Nastran

Corrected Version 70.5.1 Abstract

Description

Miscellaneous - Ishell does not work on HP Systems The ISHELL module will not work on the HP Version 70 system because the allocated size of the stack and child thread was too small for HP machine. The original cause of this error was fixed in Version 70.5.0 but another error effectively renders the error not fixed on HP-UX 10.2 systems. The error has been fixed in Version 70.5.1. Avoidance: There is no avoidance.

Known Error

CR 30027

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Optimization/Design Sensitivity - SPCD, scr=no, auxiliary models - Wrong Answers In a shape optimization run with SPCD loads on auxiliary models and scr=no the answers are wrong after the first cycle. Avoidance: Use scr=yes or insert the following DMAP avoidance:

Description

compile update alter 'delete \/yg1,' DBVIEW ygp=yg (WHERE DESITER=DESP) $ RESTART YGp,YG,//TRUE $ DETECT ENFORCED DISP CHANGES endalter

Known Error

CR 30030

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Aeroelastic Analysis - SSG2 - Poor Efficiency The ssg2 module reduces the spline matrix gtkg to several other components. The r-set component is not used anywhere, and this operation takes a considerable amount of cpu time.

Description

Avoidance: An alter which eliminates this computation is to remove this component from the dmap call: COMPILE AESTAT NOLIST NOREF $ V70 ALTER 'SSG2','' $ REMOVE GTKR FOR EFFICIENCY. NOT USED DOWNSTREAM. $SSG2 USET,GM,,,GOA,DM,GTKG/GTKR,GTKO,GTKS,GTKA,GTKL $ SSG2 USET,GM,,,GOA,DM,GTKG/,GTKO,GTKS,GTKA,GTKL

Known Error

CR 30037

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Optimization/Design Sensitivity - DESOPT, TFL - UFM 3055 If the TFL command is specified and ANALYSIS=MFREQ or DFREQ in a SOL 200 run that performs adjoint sensitivity then the run will fail with UFM 3055 at statement 404 in subDMAP DESOPT.

Description

Avoidance: Insert the following DMAP alter: compile desopt alter 'PARAML CASERS' PARAML CASERS//'DTI'/1/ 15// S,N,TFL $

Known Error

CR 30041

Product

MSC / MD Nastran

Corrected Version 70 Abstract

Installation/Security - No read access to authorize.dat or license.dat Files If the user running mscsetup has their umask set to a value that disables group or other access, e.g., 026 or 027, mscsetup may create files that are not readable by the user community. The specific files of concern are:

Description /flexlm/licenses/license.dat and/or /conf/authorize.dat. Note, having a restrictive umask value is a necessary, but not sufficient,

Known Error

CR 30041 condition for the error to occur. This error has been corrected on the MSC/NASTRAN V70 (r4) CD. Avoidance: Either of the following actions below will avoid the error. 1) Set the umask to 022 before running mscsetup. or 2) Change the permissions of the affected files after installation, e.g., chmod a+r /flexlm/licenses/license.dat chmod a+r /conf/authorize.da

Known Error

CR 30045

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Frequency Response Analysis - CDAMP1, CBUSH - Wrong SPCFORCE Output If frequency dependent damping and no stiffness is specified on a CBUSHelement then the SPC forces will be wrong. Avoidance: Insert the following DMAP alter:

Description

compile freqrs alter 'equivx bggf\/xggf','' ADD bggf,/xGGf/iomega $ endalter

Known Error

CR 30054

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Description

Eigenvalue Analysis - STATSUB, PARAM,INREL - UFM 9058 (SUPER3) If a PARAM,INREL,-1 is erroneously placed in a SOL 103 run along with a STATSUB command for differential stiffness, then the following error message will be received: ^^^ USER FATAL MESSAGE 9058 (SUPER3) - THE SOLUTION FOR THE RESIDUAL STRUCTURE DOES NOT EXIST.

Known Error

CR 30054 This error needs to be trapped in order help the user correct the problem. Avoidance: Remove the PARAM,INREL,-1 since it is only valid for inertial relief in SOL 101.

Known Error

CR 30058

Product

MSC / MD Nastran

Corrected Version 70.5.2 Abstract

Documentation - Incorrect Specification of FLEXlm License Servers on Windows NT The MSC/NASTRAN Version 70.5 NT "Configuration and Operations Guide" indicates the format for a list of alternate FLEXlm licensing files or license server nodes is specified as value:value:...

Description The correct format for NT machines is value;value;... Note, ANY list of values, such as a PATH, or the FLEXlm license spec, use semicolons on Windows NT. Known Error

CR 30064

Product

MSC / MD Nastran

Corrected Version Abstract

Matrix Methods - UDECOMP - Various User and System Fatal Messages As problem sizes get larger the unsymmetric solver becomes less robust and the program may fail after significant time is spent in the module. Avoidance: The use of the unsymmetric solver can be avoided for some solutions by:

Description

SOL 108, fluid structure analysis. The default method now selects the symmetric solver, where possible. Do not use PARAM, ACYM, NO, because it forces use of the unsymmetric solver. The default value for this parameter since Version 69 provides the correct action.

Known Error

CR 30064 SOL 144. Several methods are introduced in Version 70.5 which avoid use of the unsymmetric solver, which is still the default method. The recommended method is requested by use of PARAM, AESMETH, AUTO. This selects an iterative solution.

Known Error

CR 30073

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract Description

Nonlinear Analysis - APPEND - SFM 4276, EC 1039 In a nonlinear run, it is possible that the run may terminate in APPEND with SFM 4276, EC 1039. Avoidance: Set SYSTEM(158)=1000 and SYSTEM(159)=500

Known Error

CR 30083

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Transient Response Analysis - TLOAD, TRL ,- time: command terminated abnormally If a transient response analysis has a DLOAD that references a nonexistent TLOAD id, the job aborts without any messages except:

Description

*** TERMINATING /pw/devl/svr4/structures/t477/nastran/msc70/solaris/analysis.ultra *** Received signal 11 (SIGSEGV) time: command terminated abnormally in the log file. Avoidance: Remove the reference to the nonexistent TLOAD id.

Known Error

CR 30101

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Superelements - Component Mode Synthesis - UFM 3007 (UMERGE)

Description

If an insufficient number of q-set degrees of freedom are allocated through the SEQSETi entry to hold all of the internally generated residual flexibility vectors, the run will fail in the UMERGE module with the message "USER FATAL MESSAGE 3007" indicating illegal input to a subroutine.

Known Error

CR 30101 Avoidance: Supply a larger number of SEQSETi degrees of freedom.

Known Error

CR 30104

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Documentation, QRG - TIME - Incorrect Default Value

Description

The default value for the executive control section entry "TIME" changed in V69. The value is now 1.892160e9 (seconds), not 60 minutes as documented. Avoidance: Specify a user defined value for TIME.

Known Error

CR 30109

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Description

DMAP - NORM - SFM 4276 EC 7777 The norm module sets an output parameter to the size of the maximum magnitude number in a matrix. On short word machines these numbers can be as large as 1.E60+. The number is stored in an output parameter of single precision whose maximum size is 1.E30+. Therefore, matrices which are legal for other modules cause overflow in norm. Avoidance: Short of not generating matrices with large numbers in them, there is no avoidance.

Known Error

CR 30124

Product

MSC / MD Nastran

Corrected Version 70.0.3 Abstract

Miscellaneous - GPWG, PARAM,GRDPNT,0 - time: command terminated abnormally Jobs with PARAM,GRDPNT on SUN SOLARIS Version 70.0.0 systems may fail in the GPWG Module with the message:

Description

*** TERMINATING /local/msc/msc70/solaris/analysis *** Received signal 11 SIGSEGV time: command terminated abnormally. Avoidance: Remove the PARAM,GRDPNT from the data deck. The error could not be repeated on Version 70.0.3 or 70.5.

Known Error

CR 30136

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Installation - "The following items are missing:" If a user or site has replaced the standard tar(1) command with another "equivalent" utility, e.g., pax(1), mscsetup may fail with the following error:

Description

The following items are missing: msc70/access where msc70/access is any file to be loaded from the CD-ROM. Avoidance: Make sure the tar command invokes the standard tar(1) executable.

Known Error

CR 30147

Product

MSC / MD Nastran

Corrected Version GL Abstract

Nonlinear Analysis - NLPCI, CRIS - Negative Load Factors If the Crisfield arc length method (TYPE=CRIS) is used in a post buckling analysis, then the job may not converge. A symptom of this problem is the printing of large negative load factors as shown below.

Description

SUBID 2 LOOPID 29 LOAD STEP -6.389 LOAD FACTOR-7.38852477 SUBID 2 LOOPID 30 LOAD STEP -7.891 LOAD FACTOR-8.89144518 SUBID 2 LOOPID 31 LOAD STEP -10.059 LOAD FACTOR*********** Avoidance: Use the RIKS method or SOL 400.

Known Error

CR 30200

Product

MSC / MD Nastran

Corrected Version 70.5.2 Abstract

Rigid Elements - RSSCON - UFM 6694, Incorrectly Worded Fatal Message When two solid elements are connected to one shell element using the ELEM option on the RSSCON entry, the following error message is issued:

Description USER FATAL MESSAGE 6694 (GP4RS4) SHELL GRID POINT xxx IS CONNECTED TO MORE THAN TWO SHELL ELEMENTS BY RSSCON BULK DATA ENTRIES.

Known Error

CR 30200 THIS IS NOT ALLOWED IF THE SOLID ELEMENT FACES CONNECTED ARE TRIANGLES. Although the user made an illegal connection, the error message is incorrectly worded. The problem is not that the shell is connected to a shell but that it is connected to two solids. The RSSCON entry can not connect more than one solid element to one shell element when the ELEM option is used. If the shell to solid connection spans across more than one solid element, the GRID option must be used.

Known Error

CR 30201

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Description

Loads - FORCE - Unexpected Answers A negative sign in the CID field of the FORCE entry may not be trapped and the analysis may continue as if the field was left blank indicating the loads are to be applied in the basic coordinate system. Avoidance: Other than checking the oload output and entering proper data in the field, there is no avoidance.

Known Error

CR 30204

Product

MSC / MD Nastran

Corrected Version Abstract

Sensitivities/Optimization - MSGMESH - MSGMESH FE 9104 Running an input file with an auxiliary model generated with MSGMESH fails with the fatal error:

Description

1 CGEN QUAD4 2001 2000 1 3 2001 2054 INPUT ** *** MSGMESH FATAL ERROR 9104 *** N1=1 N2=5 N3=0 N4=0 ERROR ** for any MSGMESH input entries. Avoidance: Do not use MSGMESH entries in the auxiliary subcase.

Known Error

CR 30205

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Dynamics - PARAM,RESVEC - Wrong Answers with MAX Normalization

Description

The Modal Augmentation (Residual Vector) Method introduced in Version

Known Error

CR 30205 70 gives wrong answers if the modes are normalized to MAX. Avoidance: Use MASS normalization of modes.

Known Error

CR 30212

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Superelements - SUPORTi, CSETi, GDR - SFM 3007 (UMERGE) When performing component mode synthesis using generalized dynamic reduction (GDR) and CSETi and SUPORTi entries are present the run may fail in the GDR module with the following message: ^^^ USER INFORMATION MESSAGE ( RESVEC ) ^^^ NO STATIC SHAPES WERE FOUND TO AUGMENT MODE SHAPES *** SYSTEM FATAL MESSAGE 3007 (UMERGE) ILLEGAL INPUT TO SUBROUTINE MERGE 0FATAL ERROR

Description

Avoidance: Apply the following DMAP alter to avoid the error: compile semr3 alter 'call resvec','' call resvec pg,uset,gm,kfs,ys,bgpdts,scstm,cstms,medge,mff, cmpho0,loo,koo,cmlama0,moo,got,koo,cmphrc/ cmpho,cmlama/ nozset/norc/seid/'o ' $ alter 'equivx cmpho0','' CALL SEGOA uset,GOT,/GOAt/NOOSET/NOQSET/NOTSET $ EQUIVX CMPHO0/PHIVZ/NORC $ IF ( NORC>

Known Error

CR 30229

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Installation - SGI R10000 misidentified during V70 installation On multi-processor SGI system running IRIX 6.2 or later, mscsetup may report a syntax error such as the following:

Description ./mscsetup[24]: 10000^J10000^J10000^J10000^J10000^J10000^J10000^J10000: syntax error

Known Error

CR 30229 Avoidance: Set the MSC_ARCH environment variable to "irix64" for any R8 or R10 processor running IRIX64, or "irix" for any other combination of processor and OS. Note, specifically "O2" systems use the "irix" architecture. For example, on an Origin2000 system, set export MSC_ARCH=irix64 # Korn shell setenv MSC_ARCH irix64 $ C-Shell

Known Error

CR 30235

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Superelements - SUPORT1, PARAM,SESEF - UFM 3055 (MPYAD) The use of SUPORT1 entries with PARAM,SESEF,>=0 and superelements will result in *** USER FATAL MESSAGE 3055 (MPYAD ) AN ATTEMPT TO MULTIPLY OR MULTIPLY AND ADD NON-CONFORMABLE MATRICES TOGETHER WAS MADE IN MODULE MPYAD.

Description

Avoidance: $V70 compile postreig nolist noref alter 4 $ type parm,nddl,i,n,suport $ alter 25 $ after call setq paraml casedr//'dti'/1/255//s,n,suport $ ENDALTER

Known Error

CR 30250

Product

MSC / MD Nastran

Corrected Version 70.5.2 Abstract

Optimization/Design Sensitivity - REPCASE - SFM 3002 (DSADJ ) The message: SYSTEM FATAL MESSAGE 3002 (DSADJ)

Description may occur when the adjoint method is invoked and there are REPCASE case control commands.

Known Error

CR 30250 Avoidance: The best avoidance is to remove the REPCASE commands. A more complex and less robust avoidance is to force the direct sensitivity method. This latter technique entails forcing the retention of an element response.

Known Error

CR 30251

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Grid Point Force - GPFORCE, SUBCOM - GPFDR - SFM 4276, EC 7777 If a run contains SUBCOMs and a GPFORCE request, the run will fail on Digital Alpha UNIX systems in the GPFDR module with the following message and traceback: SYSTEM FATAL ERROR 4276.tbk ERROR CODE 7777 PID= 0 USER INFORMATION MESSAGE: TO OBTAIN A NASTRAN DUMP, RESUBMIT JOB WITH DIAG 44 INSERTED IN THE EXECUTIVE CONTROL SECTION.

Description

Process Id = 9467 handler(0x11ffff138,0x0,0x120974d00,0x150fb59a4,0x1405fd6c0) L. 24 (0x120974d00,0x150fb59a4,0x1405fd6c0,0x8,0xc00000007) L. 24 gpfdr_(0x1409ac7b0,0x11ffff494,0x14057e9b0,0x14057e9b4,0x1409ac7b4) L. 1057 xsem13_(0x12005727c,0x11ffff915,0x11ffff710,0x0,0x1) L. 94 mainal_(0x11ffff710,0x0,0x1,0x0,0x3ffc0082620) L. 349 (0x140a40188,0x0,0x100000000,0x100000001,0x100000000) L. 349 <

Known Error

CR 30252

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Heat Transfer - RADMTX - Duplicate Continuation Entries in Punch File If a heat transfer analysis contains multiple cavities and each cavity exceeds 100,000 elements the duplicate continuation entries for RADMTX may be output to the punch file.

Description This problem only occurs when each cavity exceeds 100,000 elements. If each cavity has more than 100,000 elements,then you will get the duplicate continuation entries on the RADMTX bulk data entry. This error will lead

Known Error

CR 30252 to: *** USER FATAL MESSAGE 4392. CONTINUATION CARD ERRORS. EXPLANATIONS FOLLOW LIST OF CARDS IN ERROR when the punch file is used. Avoidance: Manually edit the punch file. The continuation fields may be left blank as long they are in order.

Known Error

CR 30254

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Complex Eigenvalue Analysis - CEAD - SFM 4276, EC 7777 If a complex eigenvalue analysis is missing a cmethod entry in the Case Control the job may end with a traceback in the CEAD module.

Description

Offset 0x00000020 in procedure raise Offset 0x00004110 in procedure bioxxx_routine Offset 0x00000134 in procedure bioxxx_ Offset 0x00000240 in procedure nsexit_ Offset 0x0000019c in procedure pexit_ Offset 0x00004048 in procedure gperr_ Offset 0x000002c0 in procedure mesage_ Offset 0x000010d8 in procedure cead_ Offset 0x00000094 in procedure xsem11_ Offset 0x000009b4 in procedure mainal --- End of call chain --Avoidance: Add a cmethod entry in the Case Control.

Known Error

CR 30259

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Heat Transfer - TETRA, PENTA, CHBDYG - Poor Answers

Description

The ten noded TETRA element and the 15 noded PENTA element produce poor answers when the convection coefficient is large relative to the thermal conductivity of the material. For example , when h*delta(x)/k is larger than 10, where h is the convection coefficient, delta(x) is the element length and, the k is the thermal conductivity of the material poor answers

Known Error

CR 30259 result.

Avoidance: Use other element types such as the 4 noded TETRA which uses CHBDYG,AREA3 for convection.

Known Error

CR 30273

Product

MSC / MD Nastran

Corrected Version 2001.0.1 Abstract

DMAP - CALL statement - UFM 72, Poor message If a value or variable is not specified for all parameters on a CALL statement then UFM 72 is issued with misleading information becaue the parameter named in the message is not the cause of the error. The error is caused by the unspecified parameter following the named parameter. For example, 83 CALL FRRD2X KDDZ,BDDZ,MDDZ,,PDFZ,FOL,CASES,

Description

EDT,SILD,USETD,/ UDVF1,FOLI1/ENFORCE///////FRRDSET//FIRSTBD0 $ 0*** USER FATAL MESSAGE 72 (XGPIDG ) PARAMETER SYNTAX ERROR IN ABOVE STATEMENT. PARAMETER IS ENFORCE --ERROR CODE = 2 Avoidance: Remove the unspecified parameters or specify dummy va

Known Error

CR 30293

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Optimization/Design Sensitivity - DEQATN - Undocumented Limit The intrinsic functions MIN and MAX for the DEQATN entry have an open ended list of arguments. There is an undocumented limitation that the number of arguments for these functions has to be less than 100. This problem is considered fixed in Version 2001 by raising the limit to 1000. Avoidance: If it is desired to take the max (or min) of more than 100 arguments,

Known Error

CR 30293 several intermediate functions can be defined that find the max of a number of arguments less than 100 and then the max of the intermediate functions will result in the overall maximum.

Known Error

CR 30299

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Optimization/Design Sensitivity - BCDR, Superelements - SFM 3002 If all the design variables and responses are specified in upstream superelements then the following messages may be issued in subDMAP PSLGDV and module BCDR: *** SYSTEM FATAL MESSAGE 3002 (BCDR ) EOF ENCOUNTERED WHILE READING DATA BLOCK (NONE) (FILE 101) IN SUBROUTINE BCDR.

Description Avoidance: There are two possible avoidances: 1. Specify at least one design variable or response in the residual structure. 2. Insert the following DMAP alter: compile desopt alter 'call descon' seid=0 $ peid=0 $ equivx cases/casdsn/-1 $ endalter Known Error

CR 30322

Product

MSC / MD Nastran

Corrected Version 70.0.5 Abstract

Description

Heat Transfer Analysis - TETRA - Wrong Answers In MSC/NASTRAN Version 70, a temperature look-up for a temperature dependent material property for the TETRA element only occurs at temperature=0.0. This causes wrong answers. Avoidance: Use other element types such as HEXA or PENTA elements when there are temperature dependent material properties in the problem.

Known Error

CR 30325

Known Error

CR 30325

Product

MSC / MD Nastran

Corrected Version GL Abstract

DMAP - Reserved Names If a parameter or datablock on a type statement uses a name that has "cond" as a prefix, for example, condnosq, then the results using these parameters or datablocks in subsequent operations are unpredictable. For example, in the following dmap operation,

Description

type parm,,rs,n,condnosq $ condnosq = 1.0 $ message //condnosq $ does not produce a value of 1.0 for the condnosq parameter. The reason is that "cond" is a dmap exec statement for branching operations. Avoidance: Do not define a datablock, parameter, or label using "cond" as a prefix for the name.

Known Error

CR 30336

Product

MSC / MD Nastran

Corrected Version Abstract

DMAP - Building a New Solution Sequence - UIM 1179 (RESDBS), Poor Message An attempt to LINK a "called SUBDMAP" (one with input and output arguments on the SUBDMAP line) will result in the following error message, which does not explain the problem:

Description

*** USER INFORMATION MESSAGE 1179 (RESDBS) A DB-DIRECTORY IMPROPERLY CLOSED IN THE PREVIOUS RUN IS BEING RESTORED BY THIS RUN. MAIN: "Access violation" (C0000005) exception encountered. MAIN: For reference, A(MAINAL) = 408540, A(/SYSTEM/) = 14ef640 MAIN: Exception occurred at address 89050D. MAIN: Program attempted to access data at location 19970738. MAIN: Context Flags 0001001F Avoidance: Do not LINK a "called SUBDMAP" only MAIN SUBDMAPs with no arguments in the SUBDMAP line are to be linked.

Known Error

CR 30367

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Dynamic Analysis - TEMP(LOAD) - Incorrect Stresses

Description

It is an undocumented limitation that thermal loads cause incorrect stresses in dynamic analysis. This limitation will be documented under TEMP(LOAD) case control entry in the Version 70.5 Quick Reference Guide.

Known Error

CR 30414

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Miscellaneous - SET - SFM 3008 Long SET case control entries may cause NASTRAN fail with the message SYSTEM FATAL MESSAGE 3008. The following SET entry resulted in this fatal: SET 1 = 1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,19,20,21

Description Avoidance: The above SET entry may be broken up as follows: SET 1 = 1,2,3,4,5,6,7,8,9, 10,11,12,13,14,15,16,17,18,19, 20,21 Known Error

CR 30419

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Description

Documentation - QRG - Description of Large Field Format Continuation Entries In the discussion in the QRG on the "Format of Bulk Data Entries" there is no mention made of how to continue a large field format Bulk Data Entry. There is an example of a large field format entry, which shows the correct use of the "*" in column 1 that marks field 1B as a continuation mnemonic of the parent entry begun in field 1A. However, in the "Continuations" discussion, there is no mention made of how to continue with child entries that are also of the large field format. These types of continuations require an "*" in column 1 of field 1B along with the continuation mnemonic of the first half of the entry. Additionally, it is stated that continuation fields can be auto-generated (the recommended practice) within MSC/NASTRAN, provided that those continuations

Known Error

CR 30419 immediately follow

Known Error

CR 30420

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Nonlinear - EIGB - SFM 6707, SFM 3007, Poor Message In a nonlinear buckling analysis, if the method on the EIGB entry is SINV or INV and no eigenvalues are found in the range, then the following misleading messages will be printed in the .F06:

Description

*** SYSTEM WARNING MESSAGE 3030 (OFP) THE OFP MODULE CANNOT PRINT THE DATABLOCK LAMA USER ACTION: USE THE MATPRN OR TABPT MODULE. PROGRAMMER INFORMATION: OFP LOC CODE = 40 FILE = 102 *** SYSTEM FATAL MESSAGE 6707 (PARAML) THE PARAML MODULE WITH P1=DTI DETECTS A STRING RECORD. *** SYSTEM FATAL MESSAGE 3007 (PARAML) ILLEGAL INPUT TO SUBROUTINE PARAML or 0*** SYSTEM FATAL MESSAGE 4540, INPUT ESTNL DATA BLOCK IS NOT NONLINEAR FORMAT. *** SYSTEM FATAL MESSAGE 3007 (NLITER) ILLEGAL INPUT TO SUBROUTINE NLINIT

Avoidance: Choose a more appropriate range on the EIGB ent Known Error

CR 30453

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Documentation - ALTER - String Based Alter, UFM 802 If a string-based DMAP alter uses the ! in the expression (find occurrence at the beginning of a line), it is possible that MSC/NASTRAN will fail with USER FATAL MESSAGE 802 stating that no match was found, even if there should be a match. Avoidance: If you encounter UFM 802, check to see that the desired line is not preceded by a comment in the DMAP. The search logic using the "!"

Known Error

CR 30453 assumes the line begins on the preceding comment. In order to avoid this, remove the ! from the text string (be careful to verify that the DMAP alter is inserted at the correct location, as this will then search for any occurrence of the text on a line, rather than only searching for lines which begin with the text). If necessary a more unique search string will have to be selected.

Known Error

CR 30459

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Estimate - Leading 0's in Integers - Poor Results If an integer has leading 0's (e.g., 05 instead of 5) on a NASTRAN bulk data entry, MSC/ESTIMATE may not interpret the data correctly.

Description

Avoidance: Remove any leading 0's from the bulk data of a file to be processed by ESTIMATE.

Known Error

CR 30462

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Estimate - Excessive Errors - Run Aborted If 'memory=estimate' or 'buffsize=estimate' is specified on the nastran command line or in an RC file, messages generated by the ESTIMATE utility may overflow a buffer within the nastran command. When this overflow occurs, the following message will appear:

Description

*** SYSTEM WARNING MESSAGE (nastran.estimate_job_requirements) a.estimate=/msc705//estimate (program default) ESTIMATE executable filename. This keyword may only be specified on the command line or in the command initialization file (see ). It appears that ESTIMATE has failed. Ensure that the program is properly installed. Assuming default value for buffsize. Avoidance: Either of the following avoidances will work: 1. Fix the errors in the input file and rerun wi

Known Error

CR 30468

Product

MSC / MD Nastran

Known Error

CR 30468

Corrected Version 70.5 Abstract

Miscellaneous - VECPLOT - SFM 3062 If a very large memory is requested in a run, then the job may fail in vecplot with the following error messages:

Description

0*** SYSTEM FATAL MESSAGE 3062 MODULE = VECPLOT FAILURE OCCURRED IN UTILITY GETGPT CALLED IN SUBROUTINE VECPL1 . PREXYZ FLAG ARGUMENT WAS SET WITH AN INCORRECT VALUE TO GET THE REQUESTED DATA RETRIEVAL. In this case, a memory of 400mw was requested. Avoidance: Reduce the amount of memory request.

Known Error

CR 30496

Product

MSC / MD Nastran

Corrected Version 2001.0.3 Abstract

Restarts - Delete Entry - Various User Fatal Messages When a restart delete entry, using the small field format, is incorrectly shifted a column to the left, the beginning and end values are misread without a fatal message. For instance the following delete bulk data entry:

Description

/ 65266 65267 is read as: / 5266 5267 Avoidance: Use free field, comma separated input for this entry.

Known Error

CR 30507

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Description

Optimization/Design Sensitivity - SDR2 - SFM 3062 A shape optimization task may fail with a system fail message, 0*** SYSTEM FATAL MESSAGE 3062 MODULE = SDR2 FAILURE OCCURRED IN UTILITY MAPXTI CALLED IN SUBROUTINE SHLNRM . REQUESTED EXTERNAL ID(S) NOT FOUND. The failure may occur when the following conditions are met:

Known Error

CR 30507 1. A shape optimization job; 2. Shell normal is invoked; 3. The identification id for grid points is larger than the total number of grids in the model. Say the model has 10 grids but the ten grids are identified by 100001 to 100010. The possible avodance: 1. Always start grid ids from 1; 2. Set SNORM=0.0. Notice that if shell normal can not be ignored, the avoidance # 1 should be used.

Known Error

CR 30515

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Restarts - EPOINT - Inefficient Restart If a restart is made from a solution 103 normal models run and epoints are added, the modes will be recalculated even though they are unaffected by the epoints.

Description

Avoidance: Use the following alter, it removes the check on DYNAMIC(s) and the restart skips the READ or REIGL module. THIS AVOIDANCE PRODUCES INCORRECT RESULTS! compile ifpl alter 158,158 compile phase0 alter 590,590 endalter

Known Error

CR 30522

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Description

Optimization/Design Sensitivity - PCOMP - SFM 5628 (DSAD12) In design optimization, if there are composite responses (DRESP1 = CSTRESS, CSTRAIN or CFAILURE) and force responses (DRESP1=FORCE), a USER FATAL MESSAGE 5628 as shown below will be encountered unless the highest element ID has a composite response. 0*** USER FATAL MESSAGE 5628 (DSAD12)

Known Error

CR 30522 DRESP1 ID = 5363003 IS FOR RTYPE = FORCE AND ELEMENT ID = 5682. THE RESPONSE COULD NOT BE FOUND, EITHER BECAUSE THE ELEMENT DOES NOT EXIST OR BECAUSE THE RESPONSE TYPE IS NOT AVAILABLE FOR THE ASSOCIATED ELEMENT TYPE. 0*** USER FATAL MESSAGE 5628 (DSAD12) DRESP1 ID = 5363004 IS FOR RTYPE = FORCE AND ELEMENT ID = 5682. THE RESPONSE COULD NOT BE FOUND, EITHER BECAUSE THE ELEMENT DOES NOT EXIST OR BECAUSE THE RESPONSE TYPE IS NOT AVAILABLE FOR T

Known Error

CR 30542

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Response Spectra Analysis - SUBCASE - Missing Output When using Response Spectrum ananlysis in SOL 103, if you have multiple SUBCASEs (solutions) and there are diffenrent output requests in various SUBCASEs, only the requests which match the first SUBCASE will be honored. Avoidance: Insert the following DMAP alter:

Description

compile postreig alter 'sdr2 ','' SDR2 CASEDR,CSTMS,MPTS,DIT,EQEXINS,,,,BGPDTS,OLB,PHQG, PHIGH,EST,XYCDBDR,,,,GPSNTS,,,/ ,IQG1,IPHIG1,IES1,IEF1,/ 'mmREIG' $ endalter

Known Error

CR 30550

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Documentation - QRG, INIT,SCRATCH - Incorrect Default

Description

The default value for the SCRATCH dbset is stated as 175,000 gino blocks in the Quick Reference Guide. The correct default value is 250,000 gino blocks.

Known Error

CR 30560

Known Error

CR 30560

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Restarts - scr=mini, SUPORT command - UWM 4410, Missing output If SCR=MINI is specified on the command line and the SUPORT command is specified in the Case Control, then subsequent data recovery restarts will terminate with UWM 4410 and no data recovery output.

Description

Avoidance: Insert the following DMAP alter: compile sestatic alter 'call setq' PARAML CASES//'DTI'/1/255//S,N,SUPORT $ endalter

Known Error

CR 30563

Product

MSC / MD Nastran

Corrected Version 70 Abstract

Description

Transient Analysis - OTIME, op2, f06 - wrong answers In Version 69.1, the OTIME command is ignored for element-type output (e.g., forces, stresses). Furthermore, the time labels are in the correct sequencial order, but the label values are incorrect. The OTIME command functions properly for grid-type output (e.g., disp, velo, acc). This problem has been corrected in Version 70. Avoidance: Either remove the OTIME command or upgrade to Version 70.

Known Error

CR 30575

Product

MSC / MD Nastran

Corrected Version GL Abstract

Optimization/Design Sensitivity - Limit on the Number of Design Variables

Description

There is a limit imposed by the optimization algorithm used for design optimization that the number of design variables (NDV). squared must be less than the number of machine precision words available. For example, if a job is run with 40 million single precision words, the number of design variables must be less than the sqrt(40,000,000/2) = 4472 on a short word machine and 6324 on a long word machine.

Known Error

CR 30578

Product

MSC / MD Nastran

Known Error

CR 30578

Corrected Version 2008.0.0 (MD R3) Abstract

Nonlinear Analysis - PARAM,LGDISP, PLOADX1, LOAD - Wrong Answers If PLOADX1 (pressure loads for axisymmetric elements) is referenced by a bulk data LOAD record, follower forces (in nonlinear solution sequences) do not work. Pressure loads are computed based upon the initial geometry.

Description Avoidance: An avoidance is to write PLOADX1 records for every load magnitude needed, and not use the LOAD records to combine loads. Known Error

CR 30585

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Installation/Security - Unable to Obtain Licenses for MSC/NASTRAN There is an error in the FLEXlm libraries provided by Globertrotter that result in the libraries ALWAYS examining the LM_LICENSE_FILE environment variable even though a valid license file or server has been explicitly named in the "authorize" keyword. As a result of this, the following limitation is set:

Description

If the LM_LICENSE_FILE environment variable is set, it shall point to a valid license file. This error is most easily seen by setting the "authinfo" value to 9 and examining the LOG file output. If a license file not named by the "authorize" keyword is present, it was obtained from the LM_LICENSE_FILE environment variable. Avoidance: Delete the LM_LICENSE_FILE environment variable if it does not point to a valid FLEXlm license file.

Known Error

CR 30590

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Nonlinear Static Analysis - Superelements, Restarts - SFM 4540

Description

When downstream superelements are processed in a SOL 106 coldstart by using SEALL=n, where n is the superelement number, NASTRAN incorrectly issues the following fatal message: SYSTEM FATAL MESSAGE 4540, INPUT ESTNL DATA BLOCK IS NOT NONLINEAR FORMAT.

Known Error

CR 30590 Avoidance: If you are using partitioned superelements and you are going to restart to process the residual, ignore the fatal message and restart anyway. The fatal message is benign and restarts are possible.

Known Error

CR 30617

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Documentation - QRG, Force(corner), strain(corner) - Incorrect default

Description

The Quick Reference Guide incorrectly lists cubic as being the same as the corner output for the force and strain output. The correct default corner option for the force and strain corner output is BILIN, similar to the stress output.

Known Error

CR 30631

Product

MSC / MD Nastran

Corrected Version Abstract

Documentation - Reference Manual, GPSTRESS - Strain Not Supported

Description

In the second paragraph of Section 10.1 of the MSC/NASTRAN Reference Manual it states "The calculation of strains may be sustituted for stresses using the STRAIN command in place of the STRESS command in the Case Control Section" inside the same paragraph that describes the GPSTRESS features. This may lead users to incorrectly conclude that grid point strain can be obtained by substituting the STRESS Case Control Command with the STRAIN command. Grid point strain output is not supported.

Known Error

CR 30638

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Description

Grid Point Force Balance - GPFORCE, PLOAD - Wrong Answers Grid point force balance output of element force contributions are not correct when pressure loads are applied. For example, PLOAD1 on BAR, BEAM and BEND elements will produce different element forces with the ELFORCE data recovery than from that printed in the grid point force balance output. The same is true of the plate elements under pressure loads.

Known Error

CR 30638 Avoidance: There is no avoidance, this is currently a limitation of the GPFDR module. The GPFDR module has as input the discrete load vector to perform the data recovery operations. The discrete load vector does not contain any of the distributed load effects and will calculate element force contributions based on the discrete loads not the distributed loads. The limitation has not been removed but is now documented under the G

Known Error

CR 30639

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Description

Optimization/Design Sensitivity - PLOAD1/BEAM - Wrong Answers A design optimization job may report incorrect element response value (Stress/Strain/Force) for CBAR, CBEAM and CBEND elements subjected to pressure loads because SOL200 does not account for distributed forces of the PLOAD1 entry while recovering those element response quantities. Avoidance: There is no avoidance.

Known Error

CR 30645

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

DMAP - User Supplied subdmaps may Discard datablocks on type Statements If a user subdmap is of the form:

Description

subdmap mine in1/out1 type db sils mod1 sils/out1 etc. etc. ... return end $ and sils is a datablock in the nddl, which means it is stored in the database, then assuming qualifiers are set correctly, module mod1 will find sils and use it appropriately. However, at the end of the execution of the subdmap the LTU logic will automatically delete the datablock. This will not be discovered until the datablock is needed by a downstream subdmap, when it will no longer be in the database. Consequences include wrong answers

Known Error

CR 30645 or mysterious fatal error crashes such as "SILS NOT AVAILABLE" for modules that allow purged inputs. These errors occur even though SILS was in the database in prior subdmaps. Avoidance: Do not write the type stateme

Known Error

CR 30703

Product

MSC / MD Nastran

Corrected Version GL Abstract

Postprocessing - XDB Limitation - Maximum Number of Grids There is a limit on the number of GRID points which can be processed by the DBC module for the ".xdb" file. The limit is dependent on many factors, one of the most significant factors is the solution sequence. For dynamic and nonlinear solution sequences the limit is 214748 GRID points. If more GRIDs than this exist in the model, some of the desired data may not be processed and placed in the ".xdb" file.

Description

Although there is still a limit on the total amount of data DBC can process, Version 70.5 contains changes that take into account the actual number of timestep or load steps actually solved. Thus, the program can more accurately predict the amount of data that it must process. The maximum number of grids is now determined dynamically and this change effectively greatly increases At 2005R2 this limitation is removed with DBCFACT=2.

Known Error

CR 30704

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Nonlinear Heat Transfer - CHBDYG - UFM 2157 The backside on an ambient plate element cannot be used for thermal radiation. If attempted the follow message results:

Description

USER FATAL MESSAGE 2157, MATERIAL ID = 0 FOR ELEMENT ID = 1 DOES NOT APPEAR ON ANY RADM RADIATION MATERIAL DATA CARD FATAL ERROR Avoidance: Add a front face RADM entry.

Known Error

CR 30712

Known Error

CR 30712

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Optimization/Design Sensitivity - PARAM,INREL, ADD - UFM 5423 The USER FATAL MESSAGE below may occur when performing an inertial relief sensitivity analysis with multiple subcases and one or more subcases does not have any retained responses. The message is:

Description

0*** USER FATAL MESSAGE 5423---ATTEMPT TO ADD INCOMPATIBLE MATRICES, (SADD5) COLS ROWS FORM TYPE NZWD DENS TRAILER FOR PL IS 6 57 2 2 50 3596 TRAILER FOR PLR6Y IS 12 57 2 2 64 5614 TRAILER FOR PLIPA IS 12 57 2 2 34 2281 FATAL ERROR Avoidance: Insert the following DMAP alter: compile desopt alter 'call descon' solapp='stnmbk' $ call dbstore caseds,casdsn,,,//0/0/' '/0 $ compile inersen alter 'plbase','qrbase' call dbfetch /caseds,casdsn,,,/0/0/0/0/0 $ type parm,,i,n,ic

Known Error

CR 30721

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Description

Optimization/Design Sensitivity - MODTRK - Eigenvectors in Wrong Order Mode tracking in design optimization seeks to place modes back into their original order if any mode switching has occurred as a result of changes made to the design. The eigenvalue summary, however, will not be correctly correlated with the eigenvector output if modes have switched, and the parameter, NASPRT is set to a positive integer to request data recovery for the intermediate design cycles. The values are correct but the order does not agree with the eigenvalue summary table. Avoidance: The following is a DMAP alter for Version 70 that correctly reorders the eigenvector summary output as a result of mode tracking. This alter has been built into Version 70.5 of MSC/NASTRAN along with some additional module MODTRK enhancements.

Known Error

CR 30721 $ $ v70 avoidance for csr 30721: $ comp

Known Error

CR 30738

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Frequency Response - QUAD4, sort2, corner, - SFM 3001, Possible wrong answers In a frequency response analysis, if SORT2 output is requested, then the following error message may be issued in data recovery after printing the element force output. *** SYSTEM FATAL MESSAGE 3001 (DPD ) THE OUTPUT DATA BLOCK IN POSITION 11 DOES NOT EXIST.

Description

Furthermore, on the SGI (and possibly other machines), a sort2, corner output request for quad4 elements may produce incorrect results that are evident by the printing of very large element forces (e.g. E+20) or "Inf". Avoidance: Use a sort1 output request with frequency response. If corner output is not being requested, and if random response is not being performed, then the following alter may avoid the problem in Version 70. compile sedrcvr souin=mscsou nolist noref $ V70 alter 'dpd'(1,-2),'dpd'(1,7) $ De

Known Error

CR 30740

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Aeroelastic Analysis - AMP, CAERO1, CAERO2 - UFM 3005, Subroutine AMPC The message:

Description

USER FATAL MESSAGE 3005 (AMP ) ATTEMPT TO OPERATE ON THE SINGULAR MATRIX SCRATCH IN SUBROUTINE AMPC FATAL ERROR will occur in the AMP module if multiple group ids are used in defining the aerodynamic model and the model contains both lifting surface entries

Known Error

CR 30740 (CAERO1) and body entries (CAER02). Avoidance: Place all the aerodynamic panels and bodies in the same interference group.

Known Error

CR 30766

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

MNE - Missing Collection on V70 MNE If you choose an installation option that does not install the PRIMARY (V70) documentation set onto the hard disk, you must do the following after executing the installation script:

Description

1. Change the current directory to /mne70, where is the directory in which you installed the MNE: cd /mne70 2. Remove the existing erroneous symbolic link to v70qrg: rm v70qrg 3. Add the correct link for v70qrg: ln -s //doc/mne70/v70qrg where is the CD-ROM mount point.

Known Error

CR 30775

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Loads - PLOADi - Incorrect Follower Forces

Description

There is an error in the follower force stiffness matrix (see PARAM FOLLOWK) due to PLOAD, PLOAD2 or PLOAD4, if the global displacement system is not in the basic coordinate system. This error occurs if the first grid point listed on the PLOADi has a non-basic coordinate system reference in field seven of the corresponding GRID entry.

Known Error

CR 30776

Product

MSC / MD Nastran

Corrected Version GL Abstract

SOL 103, Element Strain Energy (ESE) incorrect when used with static preload (STATSUB)

Description

The element strain energy output for modes found in SOL 103 using STATSUB

Known Error

CR 30776 is incorrect. It includes only the linear portion of the ESE; the differential stiffness contribution is ignored. Avoidance: The following alter will calculate the strain energy contribution of the differential stiffness in addition to the linear portion: $ the following dmap is for V70 SOL 103 with STATSUB $ after the solution completes, there are 2 ESE outputs $ 1st: unstiffened ESE due to KELM $ 2nd: stiffened ESE due to KDELM $ combine these to get the total modal ESE $ this has not been tested with superelements. COMPILE SEKDR,NOLIST,NOREF ALTER 'EMG.*KDELM' $ CALL DBSTORE KDELM,KDDICT,,,//-99/SEID/'DBALL'/0 $ COMPILE SEDRCVR,NOLIST,NOREF ALTER 'OFP.*ONRGY1

Known Error

CR 30782

Product

MSC / MD Nastran

Corrected Version GL Abstract

Static Condensation - Approximate Results for Differential Stiffness

Description

Static Condensation is approximate for differential stiffness which is used in buckling analysis, nonlinear analysis, and analysis that uses the STATSUB entry. Users can use this knowledge to omit local modes from their buckling analysis, but it can also lead to poor or unexpected results depending on the geometry and degrees of freedom omitted by static condensation. Static condensation occurs when there are superelements, ASET, ASET1, BSET, BSET1, BNDFIX, BNDFIX1, BNDFREE, BNDFREE1, CSET, CSET1, or OMIT, OMIT1 entries in a model.

Known Error

CR 30797

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Utilities - ESTIMATE - Poor Diagnostics

Description

The ESTIMATE program is currently limited to estimating resources for models composed of GRID and connectivity entries. If no GRIDS are present, ESTIMATE will return a USER FATAL MESSAGE or may indicate NaNQ for memory or disk

Known Error

CR 30797 estimates. If no recognized connectivity bulk data entries are present, ESTIMATE will return DOF=-2**(32-1). Avoidance: Do not use the ESTIMATE program for models as described above. Do not use either the "memory=estimate" or "buffsize=estimate" keywords on a nastran command for models as described above.

Known Error

CR 30805

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

Nonlinear Analysis - Multiple Subcases - Error in Bisection logic, Infinite LoopSFE 3002 (TOLAPP) In a nonlinear analysis, in some instances, the load factor tolerences may be in error. When this occurs the value of the load factor exceeds 1.0 and the solution may enter an infinite loop or produce some other error later on. The problem is identified when one of the load factors > 1.0 Avoidance: On the NLPARM entry increase the ninc field by 1 and restart into the offending subcase. This will change the tolerance

Known Error

CR 30810

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Optimization/Design Sensitivity - SEP1A - Infinite CPU Loop When the analytic boundary shape option is used for a shape optimization task and a local coordinate system is defined for the auxiliary boundary model, the job may fall in an infinite loop in the SEP1A module. Avoidance: Do not define local coordinate systems in the auxiliary boundary model.

Known Error

CR 30852

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

Postprocessing - PARAM,POST,-4 - UIM 1207, UIM 1206 If PARAM,POST,-4 is used and FORMATTED output is requested in the OUTPUT2 file, error messages 1207 and 1206 will occur indicating that several datablocks have not been written to the file. An example of these message are:

Known Error

CR 30852 USER INFORMATION MESSAGE 1207 (OUTPN2) THE DATABLOCK KDICT /KDICT DEFINED AS NDDL TYPE KDIC IS NOT SUPPORTED BY NEUTRAL FILE TRANSLATION. THIS DATABLOCK WILL NOT BE TRANSLATED TO NEUTRAL FORMAT 0*** USER INFORMATION MESSAGE 1206 (OUTPN2) THE DATABLOCK OPHIG /OPHIG IN AN OUTPUT2 REQUEST IS NOT DEFINED IN THE MSC/NASTRAN DATA DEFINITION LANGUAGE (ND This is due to the fact that these datablocks are not described in the NDDL.

Avoidance: Use binary OUTPUT2 if PARAM,POST is set to -4. Known Error

CR 30903

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

Superelements - PARAM,AUTOSPC - Incorrect Constraint If two or more superelements which have no internal constraints applied, meet at a single GRID point, and no elements which are not in those superelements connect to that GRID point, AUTOSPC may incorrectly constrain that point. The reason for this is that the reduced stiffness matrix at a single point for a determinate structure with no constraints is a null matrix. This limitation is unlikely to affect real world models since it is unlikely that the boundary between superelements will be comprised of a single point.

Avoidance: 1. Put the DOFs you want as dynamic analysis variables on spcoff bulk data entries. 2. Put in small springs to ground, large enough to turn off autospc but not large enough to change dynamic analysis results. This is the most practical method for supere Known Error

CR 30947

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Static Analysis - MATTi - SDR2, biomsg error 7777

Description

For a large job on the hp (hpux), if temperature-dependent material property

Known Error

CR 30947 exists in the model, then the job may fail in SDR2 with following error messages: ***** RECEIVED SIGNAL 8, ABORTING ... BIOMSG: ERROR 7777 HAS OCCURRED IN ROUTINE RECOVR , FILE INDEX (FILEX) =0 Avoidance: Remove the MATTi entry and define the desired properties at the appropriate temperature on the MATi entries since for a linear analysis, the temperature-dependent lookup is only performed once in the beginning of the run.

Known Error

CR 30959

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

Nonlinear Analysis - CGAP, PGAP - Possible Wrong Answers when U0 is Negative Use of a gap element (tmax>=0.) with a negative value of U0 when GA and GB are NOT coincident may lead to wrong answers. Consider two grids on the x-axis with GA to the left of GB and the CID field blank and U0 specified to a negative value. Then the gap will always try to push GA to the left and GB to the right regardless of whether GA comes first or GB comes first in field 4 on the CGAP entry. Thus, a press fit with the inner radius of the outer disk at GA and the outer radius of the inner disk at GB would always pull in the wrong direction when UO is negative. Avoidance: To make the gap sensitive to the order of GA and GB with U0 negative, the CID entry of field 9 must be specified.

Known Error

CR 30969

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

GPFORCE - SET, GPFORCE - Poor Message, SFM 4276, EC 3061, SWM 3002

Description

If a GPFORCE request is made for a SET that only contains grid points attached to rigid elements then the deck will fail in the GPFDR module. The exact message encountered may vary. The following messages have been encountered: SYSTEM FATAL MESSAGE 4276, ERROR CODE 3061 or

Known Error

CR 30969 *** USER WARNING MESSAGE 2354 (GPFDR) MODULE IS UNABLE TO CONTINUE AND HAS BEEN TERMINATED DUE TO ERROR MESSAGE PRINTED ABOVE OR BELOW THIS MESSAGE. THIS ERROR OCCURRED IN CODE WHERE THE VARIABLE -NERROR- WAS SET = 33 *** SYSTEM WARNING MESSAGE 3002 (GPFDR) EOF ENCOUNTERED WHILE READING DATA BLOCK SCRATCH (FILE 303) IN SUBROUTINE GPFDFA Avoidance: GPFDR does not support rigid elements, request MPCFORCE output instead.

Known Error

CR 30976

Product

MSC / MD Nastran

Corrected Version 70.5.1 Abstract

Description

Online Documentation - Installation The UNIX installation aborts if you choose an installation option that installs the V69.X documentation set on the hard disk. The old V69 documentation is duplicated on this CD only for those customers still running MSC/NASTRAN V69 or V69.2. If you use MSC/NASTRAN V70, we recommend not installing V69.X documentation onto your hard disk, since all the documents applicable to V70 are already contained in the Standard installation. If you occasionally need to refer to V69 documentation, it is best to access it directly from the CD. If you frequently need V69-specific documentation and you prefer to access it from the hard disk instead of the CD, please follow the Installation Instructions on the pink sheet included with the delivery package.

Known Error

CR 30981

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract Description

Online Encyclopedia - INSTALL.txt on V70 Online Encyclopedia is Incorrect The INSTALL.txt file on the MSC/NASTRAN Version 70 Encyclopedia (MNE) is incorrect. It is the file for MSC/NASTRAN Version 70 not the MNE. Avoidance: Either view the INSTALL.htm file using a web browser or request

Known Error

CR 30981 a printed copy of the file from MSC.

Known Error

CR 30987

Product

MSC / MD Nastran

Corrected Version GL Abstract

Eigenvalue Analysis - EIGRL, GMINTC, GMINTS - Possible Missing Roots, SFM 5407 The Lanczos method of eigenvalue extraction does not work well when interface elements (GMINTC or GMINTS) are present, roots may be missing in the range. This may lead to the message:

Description

SYSTEM FATAL MESSAGE 5407 (LNCS1D) INERTIA (STURM SEQUENCE) COUNT DISAGREES WITH THE NUMBER OF MODES ACTUALLY COMPUTED IN A (PARTIAL) INTERVAL Avoidance: If interface elements are present, the SINV method is recommended.

Known Error

CR 30995

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Acoustic Analysis - GE on MAT10, PARAM,ACSYM,YES - Wrong Answers If GE is specified on the MAT10 entry and PARAM,ACSYM is YES (default) then the answers will be wrong. Avoidance: Insert the following DMAP alter:

Description

compile gma alter 'if ( app=\'tranresp\''(2),'' alter 'if ( app=\'tranresp\''(3,-1) if ( app='tranresp' or soltyp='direct' or modacc>=0 ) then $ alter 'k4hh','' if ( nok4dd>0 ) then $ if ( acsyml ) then $ add5 ifdd,,,,/mifdd/-1. $ MERGE isdd,,,mifdd,VAFSE,/idd $ mpyad k4dd,idd,/k4ddx $ SMPYAD PHDH,K4DDx,PHDH,,,/K4HH/3////1 $ else $

Known Error

CR 30995 SMPYAD PHDH,K4DD,PHDH,,,/K4HH/3////1 $ endif $ endif $ nok4dd>0 endalter

Known Error

CR 31000

Product

MSC / MD Nastran

Corrected Version GL Abstract Description

Eigenvalue Analysis - READ - Initial Vectors Ignored The READ module has provisions for initial vectors as input for the Lanczos method. These vectors are ignored in the READ module. Avoidance: Use the REIGL module.

Known Error

CR 31003

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

DMAP - MATMOD Option 12 - Wrong Answers The form of the column vector output in MATMOD option 12 is 7 (labeled "ROW VECTOR") and should be 2 (labeled "ROW RECTANG.").

Description

Avoidance: Run MODTRL on the output; for example, MATMOD I1,I2,I3,,,/O1,O2/12 $ MODTRL O2// / /2 $

Known Error

CR 31027

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Miscellaneous - PARAM,CHECKOUT and PARAM,PRTPG, SSG1 - SFM 3003 If PARAM,CHECKOUT,YES and PARAM,PRTPG,YES are specified, and thermal loads are also applied, then SYSTEM FATAL MESSAGE 3003 will terminate the run in the SSG1 module in the PHASE0 subDMAP.

Description

Avoidance: Insert the following DMAP alter: compile phase0 alter 'ssg1 ','' SSG1 SLT,BGPDTS,CSTMS,SILS,EST,MPTS,ETT,EDT,MJJX,CASESX, DIT,,DEQATN,DEQIND,GPSnts,cstm0,scstm/ PJX,PTELEM,NEWSLT/

Known Error

CR 31027 LUSETS/1//'ALL '/ALTSHAPE/TABS/seid $ endalter

Known Error

CR 31037

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Superelements - SEMA, SEBNDRY, SECONCT, SEEXCLD - UFM 4192, UFM 7341, UFM 6787 Two errors relating to checking the input on the SEBNDRY, SECONCT and SEEXCLD entries have been discovered.

Description

1. The SEIDA field is not verified to be restricted to partitioned superelements. The failure to check this may cause UFM 4192 to occur in SEMA. This message may be followed by a SFM 3062 concerning the MAPBTI utility. The true message is UFM 7341. 2. Conflicts in grid usage between the SECONCT and SEEXCLD is not properly verified and should have result in UFM 6787. Avoidance: Follow the rules for the entries delineated in the Quick Reference Guide.

Known Error

CR 31051

Product

MSC / MD Nastran

Corrected Version 70.5.2 Abstract

P-elements - GMSURF, GMCURV, GP0 - Segmentation Violation If you use an EQUATION or Aries BSP for geometry evaluation, in other words, if "MSCGRP1", or "MSCABS" is specified for the 'group name' field on the GMCURV or GMSURF entries the job may fail with the following traceback in GP0:

Description Trap encountered: SIGSEGV - Segmentation violation Traceback: Offset 0x000003d4 in procedure get_edge_info

Known Error

CR 31051 Offset 0x000000e8 in procedure abspnt Offset 0x000000a8 in procedure ngpont_ Offset 0x00000b80 in procedure gp0dx_ Offset 0x00000680 in procedure gp0dc_ Offset 0x000017c8 in procedure gp0da_ Offset 0x00000cf8 in procedure gp0_ Offset 0x000004b0 in procedure xsem02_ Offset 0x000009a8 in procedure mainal

--- End of call chain --Avoidance: There is no avoidance. Known Error

CR 31054

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Documentation - SEBULK, SECONCT, SEEXCLD, SELABLE, SELOC, SENQSET UWM 9013 In the interest of upward compatibility, several of the bulk data entries implemented in Version 69 will only work if PART superelements (BEGIN SUPER) exist. These entries are: SEBULK, SECONCT, SEEXCLD, SELABEL, SELOC, SEMPLN, SENQSET, SETREE. Avoidance: Do not use these entries unless you have defined PART superelements.

Known Error

CR 31067

Product

MSC / MD Nastran

Corrected Version 70.5.1 Abstract

Miscellaneous - SFM 4276 EC 7777, signal 10 It is possible, but not probable, that a file run on the HP9000 using the analysis.pa2_0 executable may fail with SFM 4276, EC 777, signal 10. This is due to a kernel error on the PA2 machines. Avoidance: There are several possible avoidances:

Description 1) run using a different BUFFSIZE or memory 2) try using a different SMEM 3) run using the older 'analysis' executable (this will avoid the error, but is slower) 4) change bpool

Known Error

CR 31069

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Optimization/Design Sensitivity - DVPREL1, DVPREL2, EMG - UFM 2042 In an optimization analysis, if a negative FID is specified on a DVPREL1/2 entry when PTYPE is not PBEAM, the job may result in the following error message:

Description

USER FATAL MESSAGE 2042 (EMG ) MISSING MATERIAL TABLE ******** FOR ELEMENT IIIIIIII Avoidance: Always use a positive FID on a DVPREL1/2 entry when PTYPE is not PBEAM.

Known Error

CR 31070

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract Description

Nonlinear Analysis - File indexing error A file indexing error may cause a nonlinear analysis to fail in the NLTRD2 module. Avoidance: Increase the bufferpool or smem.

Known Error

CR 31071

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

DMAP - PARAML DTI option - Wrong Answers If the PARAML module DTI option is used to extract a character string then the variable contains both the value from the selected word in the record and also the value in the next word; e.g., PARAML TABLE//'DTI'/1/45////S,N,STRING $

Description

the variable STRING will contain the character value from the 45th and 46th word. Avoidance: Add the following statement after the PARAML module: STRING=SUBSTRIN(1,4,STRING) $

Known Error

CR 31073

Product

MSC / MD Nastran

Corrected Version 70.6

Known Error

CR 31073

Abstract

DMAP - MATMOD OPTION(17) - UFM 6968 MATMOD OPTION(17) is designed to read the PARTN case control entry. When PARTN is present, it sets p4 to 0, properly. When it is not present it sets p4 to -1, also properly, but also outputs ›

Description

*** USER FATAL MESSAGE 6968 (MTMD17) NO GRID OR SCALAR POINTS IN SELECTED SET. PARTITIONING VECTOR N›ULL. However, execution continues. Avoidance: Ignore the message, or test for the presence of a PARTN command, and branch over the module if none is present. SSSALTER evds103.f705 demonstrates this avoidance.

Known Error

CR 31076

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Nonlinear Transient Heat Transfer - PENTA(15) - Failed Convergence

Description

If there are temperature dependent material properties in the model and you are running a transient thermal analysis using the PENTA(15) element the run will fail to converge. Avoidance: Use lower order PENTA elements.

Known Error

CR 31083

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Superelement - SET, THRU - Extra Output In a superelement analysis, if output is requested with a SET command using multiple "thru" ranges, then extra output that is not specified in the range may appear in the output in addition to the requested output. An example of the offending SET command is as follows:

Description

SET 100 = 1 THRU 10, 80 THRU 90 DISP = 100 The displacements for grid points that are outside of the range may appear in addition to output for the above grid points. The answers are, however, correct.

Known Error

CR 31083 Avoidance: If the extra output is not desired, then specify the SET explicitly without using the THRU range. The above example can be modified as shown below: SET 100 = 1,2,3,4,5,6,7,8,9,10, 80,81,82,83,84,85,86,87,88,89,90 disp = 100

Known Error

CR 31096

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

P-Elements - GP4 - BIOMSG: ERROR 1044 OCCURRED IN ROUTINE FILPS2 A P-element analysis with coordinate systems may fail in the module GP4 with the message:

Description

BIOMSG: ERROR 1044 HAS OCCURRED IN ROUTINE FILPS2 , FILE INDEX (FILEX) = 0 STATUS = 0 Avoidance: Increase the memory request.

Known Error

CR 31101

Product

MSC / MD Nastran

Corrected Version Abstract

P-Elements - PLOT, SDR2 - SFE 4276 EC 211 The nastran plotter does not support the plotting of p-element results. If the nastran plotter is requested with p-elements, then the job will fail with the following unclear messages.

Description

BIOMSG: ERROR 211 HAS OCCURRED IN ROUTINE BLPK68 , FILE INDEX (FILEX) =0 STATUS = 0 0*** SYSTEM FATAL ERROR 4276.BLPK68 ERROR CODE 211 PID= 0 0*** USER INFORMATION MESSAGE: TO OBTAIN A NASTRAN DUMP, RESUBMIT JOB WITH DIAG 44 INSERTED IN THE EXECUTIVE CONTROL SECTION. Avoidance: If plotting of p-element results is desired, use MSC/PATRAN.

Known Error

CR 31104

Product

MSC / MD Nastran

Known Error

CR 31104

Corrected Version 70.5 Abstract

Matrix Methods - MPYAD - SFM 4276, EC 7777 It has been observed on a very large problem, if the matrices are very dense, then the job may fail in MPYAD. On some machines, the following message may appear at the bottom of the f06 file. ***** RECEIVED SIGNAL 8, ABORTING ... BIOMSG: ERROR 7777 HAS OCCURRED IN ROUTINE RECOVR , FILE INDEX (FILEX) = 0 STATUS = 0 On other machines, there is no messages in the f06 file, but the following messages may appear in the log file:

Description Trap encountered: SIGTRAP - Trace trap Traceback: Offset 0x00000024 in procedure gino_ Offset 0x000007bc in procedure mpytim_ Offset 0x00000708 in procedure mpyad_ Offset 0x000004f8 in procedure dmpyad_ Offset 0x0000029c in procedure xsem07_ Offset 0x000008f4 in procedure mainal This is due to an o Known Error

CR 31105

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Superelements - Duplicate Point ID's on Boundary Lead to UFM 6794 When a model with list superelements has part superelements added to it, duplicate grid points at the boundary of the list superelements are not allowed, although they were allowed prior to Version 69. This condition leads to following error message:

Description

USER FATAL MESSAGE 6794 (SEPSEB) DUPLICATE BOUNDARY POINTS DETECTED IN UPSTREAM SUPERELEMENT xxx WHILE SEARCHING 0 AT GRID yy. LIST FOLLOWS:

Known Error

CR 31105 Avoidance: Remove the part superelements, or move one of the offending grid points.

Known Error

CR 31114

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Database - DBUNLOAD - Signal 11 Writing LLL If the NEUTRAL option is used in DBUNLOAD, the run will fail. The f06 will likely contain no message, the log file will contain a message of the form: ***** RECEIVED SIGNAL 11, ABORTING ...

Description

BIOMSG: ERROR 7777 HAS OCCURRED IN ROUTINE RECOVR , FILE INDEX (FILEX) =0 STATUS = 0

Avoidance: Use the BINARY DBUNLOAD. Known Error

CR 31118

Product

MSC / MD Nastran

Corrected Version 70.0.5 Abstract

GPFORCE - GPFDR, TEMP(LOAD) - SFM 6218 If a model has thermal loadings and GPFORCE is requested, the run may terminate with SFM 6218 in the GPFDR module.

Description

Avoidance: Remove the request for GPFORCE or the thermal loads. Defining SETs (which omit the GRID points connected to the element mentioned in the message) for GPFORCE may avoid the problem.

Known Error

CR 31139

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

DMAP - SAMEAS Keyword in NDDL - Poor Message and Wrong Answers.

Description

If SAMEAS,recnam is specified in the NDDL and RECORD=recnam is specified below SAMEAS,recnam then the following message is issued but the run is not terminated. *** SAMEAS CTETRA NOT FOUND

Known Error

CR 31139 RECORD=recnam must appear above SAMEAS,recnam. ›Avoidance: There is no avoidance.

Known Error

CR 31141

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

Eigenvalue Analysis - EIGRL, very large v2 - Possible Wrong Answers If the specified V2 value on the eigrl entry is substantially larger than the last mode found and the absolute value of V2 is large (e.g., 99999.), then the eigenvectors may be incorrect. This can lead to incorrect responses in a subsequent modal response analysis. This error is most likely to occur if there are massless degrees of freedom and/or large mass in the model and the above conditions exist. If the model is stable, a possible symptom of this error is large rotational displacements in the eigenvectors. This error does not occur with the new Lanczos method which is the default method in Version 70.5. Avoidance: There are two possible avoidances: 1. In v70.5, use the new Lanczos (the default method). 2. Based on the last eigenvalue calculated and the sturm sequence

Known Error

CR 31145

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Nonlinear Analysis - Restarts into Dynamic Analysis for Base Excitation

Description

A method to perform automatic restarts from static nonlinear analysis (SOL 106) to linear dynamic analysis (SOLs 103-112) has been avaialble for several versions. The resart runs have limitations on the type of data that can be changed. A Technical Application Note (TAN) describing this capability can be obtained from your MSC Technical Represenative.

Known Error

CR 31150

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Optimization/Design Sensitivity - PARAM,OPTEXIT - Incorrect Termination Message

Description

When optexit is set to -4 (output design sensitivity information into an external file) for a design optimization input file, the task terminates

Known Error

CR 31150 with an incorrect message: RUN TERMINATED DUE TO MAXIMUM NUMBER OF DESIGN CYCLES = IIIII. The correct message should be RUN TERMINATED DUE TO PARAMETER OPTEXIT = -4.

Known Error

CR 31154

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Description

Superelements - Duplicate Element ID's not Detected It is a rule of superelement usage that element ids must be unique across all element types, including structural, rigid, and plot elements. When part and grid list superelements are in one model, duplicated element ids in the list superelements are not detected. The results are difficult to predict. Some models have computed correct results, but it is possible that others would either give wrong answers or take confusing fatal exits. Avoidance: An avoidance is to perform a data check run where all of the part superelements are removed. This will result in a different path through the code which will identify all illegal duplicate element ids.

Known Error

CR 31155

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Buckling, Nonlinear Analysis - CBEAM, CQUAD4, ZOFF, OFFSET - UFM 6174

Description

Offsets should not be used for the beam and plate elements in a buckling or nonlinear analysis. This is a documented limitation. However, the action taken for the beam and plate element with offsets is inconsistent. In the case of a beam element, the job terminates with UFM 6174; however, in the case of the plate element, the job continues without any messages.

Known Error

CR 31189

Product

MSC / MD Nastran

Corrected Version 70.5.2 Abstract

Nonlinear Analysis - NLITER, CREEP - SFM 4276, EC 7777 Nonlinear analysis with creep and temperature loads may fail in the NLITER module with the message:

Description

0*** SYSTEM FATAL ERROR 4276.tbk ERROR CODE 7777 PID= 0 The traceback will indicate the routine nmcrd. Other machines may produce

Known Error

CR 31189 NaN's in the output. Avoidance: The only avoidance is to use Version 70.5.2 where the error has been fixed.

Known Error

CR 31209

Product

MSC / MD Nastran

Corrected Version GL Abstract

Eigenvalue Analysis - READ, REIGL - SFM 5401 If f1 is set on an eigrl entry to avoid computing rigid body modes, and f1 is much closer to the origin than the first flexible mode's frequency, than SYSTEM FATAL MESSAGE 5401 may be encountered.

Description

Avoidance: An avoidance is to first run with f1 blank. It should be possible to compute the flexible modes, as well as the rigid body modyes. On a second run, set f1 10% below the first flexible mode.

Known Error

CR 31218

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

GPFORCE - SUBCOM, TEMP(LOAD) - Missing Forces of SPC

Description

GPFORCE output for SUBCOMs with thermal loads will be missing the contribution of the Forces of Single Point Constraint. Standard SUBCASE processing will be correct.

Known Error

CR 31225

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Description

Elements - PBAR/PBARL, PBEAM/PBEAML - UFM 4382, Wrong Answers A job that includes PBARs and PBARLs with the same PID will issue USER FATAL MESSAGE 4382 and then continue to run. The same behavior is seen with PBEAM/PBEAML.

*** USER FATAL MESSAGE 4382 (IFP9 ) PBARL AND PBAR IDENTIFICATION xxx WAS DUPLICATED Known Error

CR 31232

Product

MSC / MD Nastran

Known Error

CR 31232

Corrected Version Abstract

Transient Analysis - LOADSET - UWM 4582 If a static pre-load is used in a modal solution, then LOADSET entry may not be used to define the dynamic loading. This combination will lead to either UWM 4582 show below (if the number of LSEQ entries is not equal to the number of static subcases) or wrong answers (if the number of LSEQ entries is equal to the number of static subcases).

Description

USER WARNING MESSAGE 4582---, LSEQ CARD SID= 100 REFERS TO A NONEXISTENT STATIC LOADS MATRIX COLUMN 2 ( NCOLS= 1 ) USER WARNING MESSAGE 4582---, LSEQ CARD SID= 100 REFERS TO A NONEXISTENT STATIC LOADS MATRIX COLUMN 3 ( NCOLS= 1 ) Avoidance: Do not use the LOADSET command when using static pre-loads.

Known Error

CR 31237

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

Online Encyclopedia - Installation If MSC/NASTRAN Online Encyclopedia (MNE) is installed on a directory path name that is too long or contains a name with embedded space characters (e.g. "Program Files"), the documentation browser will not execute properly. Avoidance: Use the suggested default directory :\msc

Known Error

CR 31249

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Heat Transfer Analysis - SFM 3002 (TAHT) If a control node is used in a very large heat transfer analysis model, then the following fatal message may be encountered:

Description

*** SYSTEM FATAL MESSAGE 3002 (TAHT ) EOF ENCOUNTERED WHILE READING DATA BLOCK NEWSLT (FILE 101) IN SUBROUTINE TAHA Avoidance: Run the job with more memory.

Known Error

CR 31256

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Optimization/Design Sensitivity - SDR2, SUBCOM - SWM 2092, ERROR 3021 If a design optimization design task contains subcoms and one or more of the subcom related subcases has no retained responses, the following fatal message may occur:

Description

SYSTEM WARNING MESSAGE 2092 MODULE = SDR2 SDR2 FINDS A SYMMETRY SEQUENCE LENGTH = xx AND AN INSUFFICIENT NUMBER OF VECTORS AVAILABLE = yy WHILE ATTEMPTING TO COMPUTE STRESSES AND FORCES. ALL FURTHER STRESS AND FORCE COMPUTATION TERMINATED. BIOMSG: ERROR 3021 HAS OCCURRED IN ROUTINE GREAD , FILE INDEX (FILEX) =0 STATUS = 0 In a related error, if a subcom contains subseq coefficients that are 0.0 and the subcase associated with this zero coefficient has no retained responses, the above fatal message may occur. Avoidance: Either remove the subcase that has no retained responses or fo

Known Error

CR 31262

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - PBEAML - Warping Coefficients are Always Set to Zero.

Description

The documentation for the PBEAML does not state that the equivalent PBEAM created will not contain warping coefficients. Avoidance: Provide the terms using a PBEAM entry.

Known Error

CR 31263

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Documentation - QRG - PARAM,ACSYM

Description

The description for the parameter "acsym" in the Quick Reference Guide states that the parameter only works for coupled fluid-structure analysis in direct

Known Error

CR 31263 frequency response. This parameter also works for coupled fluid-structure analysis in modal frequency response.

Known Error

CR 31266

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Description

Documentation - QRG, DRESP1 The Quick Reference Guide states that the PKNL method can be used in the evaluation of a DRESP1 with RTYPE=FLUTTER if the word `PKNL' is placed in the ATTB field of the DRESP1 entry. This is an error, it should be placed in the PTYPE field of the DRESP1 entry. Avoidance: Move PKNL from the ATTB to the PTYPE field.

Known Error

CR 31271

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Documentation - DECOMP, PARAM,AUTOSPC,NO - Unexpected Answers If the automatic grid point singularity check is turned off (param,autospc,no), and there are singularities in the model, then the run may continue and produce large deflections. The next release of the Quick Reference Guide will warn the user that if param,autspc,no is set, then the user should take extra caution analyzing the results in the GRID POINT SINGULARITY TABLE, EPSILON output as well as all warning messages.

Known Error

CR 31278

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Superelements - DBLOCATE, SERST,SEMI - UFM 4188 A superelement job that contains PARAM,SERST,SEMI and attempts to add the bulk data for a new superelement fails with the message:

Description

USER FATAL MESSAGE 4188 QUAD4 ** REFERENCES UNDEFINED GRID POINT **. Avoidance: Apply the following alter: COMPILE IFPS1 nolist noref

Known Error

CR 31278 alter 60 $ putsys(1,109) endalter

Known Error

CR 31304

Product

MSC / MD Nastran

Corrected Version GL Abstract

Transient Analysis - PARAM,ADSTAT,YES with TEMP(LOAD) - Wrong Answers

Description

For SOL 109 and 112 a STATSUB can be used to define a preload. The default for PARAM,ADSTAT is YES, which implies that the static displacements, SPC forces and MPC forces will be included in the output. There are limitations such as the static load is not included. Another limitation is that element forces and stresses will be incorrect if thermal expansion was used in either the static preload or the dynamic load.

Known Error

CR 31308

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Element Strain Energy - ESE(PUNCH), CELASi - Missing Punch Output In MSC/NASTRAN Version 70, if ESE(PUNCH) is requested and there are CELAS1 elements in the model, then there will be no output in the punch file.

Description Avoidance: Insert NASTRAN SYSTEM(210)=1 at the top of the MSC/NASTRAN input file. Known Error

CR 31312

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Aeroelastic Analysis - CAERO2 - Possible Wrong Answers

Description

If the aerodynamic coordinate system is not aligned with the basic coordinate system, the geometry of CAERO2 slender bodies IN THE BASIC COORDINATE SYSTEM (BGPA or BGPDT where MODLTYPE=aerostruc) may be incorrect. These data are used in Spline calculations, so that, if the geometry is affected in such a way as to shift the location of the body relative to the spline computational coordinate system, erroneous results may be obtained. The geometry in the aerodynamic coordinate system is not affected, so the "rigid aerodynamic" data are not affected--only the spline matrix MAY BE affected.

Known Error

CR 31312 It has been observed, however, that certain erroneous transformations in combination with TYPEs of CAERO2 bodies (Z, Y or ZY) can yield identical answers even if the transformation error has moved the bo

Known Error

CR 31318

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Composite Analysis - SEDRCVR - SFM 4276, EC 7777

Description

Large composite models that request large amounts of data recovery may fail on CRAY systems with SYSTEM FATAL MESSAGE 4276, ERROR CODE 7777 in the SEDRCVR module.

Known Error

CR 31322

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Heat Transfer - RSSCON and PARAM,HEATSTAT - SWM 3001 in SEP1X, Wrong answers If PARAM,HEATSTAT,YES is specified in SOL 101, then SWM 3001 will be issued by the SEP1X module. Theis warnings may safely be ignored unless there are RSSCON elements present, in which case, wrong answers may result.

Description

Avoidance: Insert the following DMAP alter: compile sestatic alter 'hsflag\=false' peid=-1 $ seid=-1 $ endalter

Known Error

CR 31323

Product

MSC / MD Nastran

Corrected Version Abstract

Description

Miscellaneous - SFM 3063, Memory Allocation Error If a run is submitted using the MEM= option and the memory allocated is above or near the limit of what is available, it is possible that the run may fail with SFM 3063 indicating that there is no more dynamic memory available.

Known Error

CR 31323 Avoidance: Always leave at lease 8mW of memory available for the system when using the MEM keyword. For example, if you are using a queue which has a 128mW limit, use a MEM value of 120mW or less.

Known Error

CR 31327

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - CSUPER - Should Reference EXTDR, EXTDROUT, EXTOUT and EXTUNIT

Description

The Version 70.5 Quick Reference Guide documentation for the CSUPER entry should be modified to reference parameters EXTDR, EXTDROUT, EXTOUT and EXTUNIT in section 6 of the QRG.

Known Error

CR 31334

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Documentation/Optimization - DVPREL1, DVPREL2 - QRG Not Updated for V70.5 Version 70.5 has simplified the interface for the design of constant section beams. The revised user interface requires changes in the Quick Reference Guide's description of the DVPREL1 and DVPREL2 entries. These changes were not completed in time before the Version 70.5 QRG was sent to press. Avoidance: The revised descriptions can be found in Appendix B of the Version 70.5 Release Notes.

Known Error

CR 31351

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Optimization/Design Sensitivity - SUBCOM - SFM 4276.GETSTR ERROR CODE 31 The message: SYSTEM FATAL MESSAGE 4276, GETSTR ERROR CODE 31

Description may occur if the user employs SUBCOMs and the adjoint sensitivity method is selected.

Known Error

CR 31351 Avoidance: Since the adjoint method is not selected when there are pelements, an easy avoidance is to tell the module that determines whether the adjoint method can be selected that there are p-elements in the model. This is done with the following dmap alter: compile descon $ alter 'dsad'(1,-1) $ type parm,,logical,n, hold $ hold=pexist $ pexist=true $ alter 'dsad' $ pexist=hold $

Known Error

CR 31364

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Aeroelastic Analysis - AEROS, ZY Bodies - Wrong Answers IF there are zy bodies in the model and the aerodynamic coordinate system is rotated about the x-axis relative to the aerodynamic reference system, wrong answers can occur in the stability derivative prints, and hence, the trim solution.

Description Avoidance: If ZY bodies are included in the analysis, make sure the aerodynamic coordinate system and the reference coordinate systems appearing on the AEROS entry are not rotated relative to each other. Known Error

CR 31374

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Elements - PBEAM, IFP - SFM 469 If a PBEAM entry contains an integer in a real field, then the job may fail in IFP without a meaningful message.

Description

Avoidance: The error was only experienced on CRAY systems. If you have access to another system then run the job on that system to identify the invalid entries and correct them.

Known Error

CR 31381

Product

MSC / MD Nastran

Corrected Version GL Abstract

Miscellaneous - INPUTT2 - UFM 1019, SFM 6551

Known Error

CR 31381 If the .dat file that is used to read the INPUTT2 file has the same prefix as the referenced INPUTT2 file--for example, test.dat is the .dat file and test.op2 is the referenced INPUTT2 file--then depending on the value of STATUS=x, the job may fail with one of the following error messages: ASSIGN INPUTT2='test.op2',UNIT=12 USER FATAL MESSAGE 1019 (OPNPFL) FORTRAN UNIT OPEN ERROR

Description

IOSTAT = 6, No such file or directory(errno=2) LOGICAL = INPUTT2 FILE = test.op2 SYSTEM FATAL MESSAGE 6551 (INPTX2) AN END-OF-FILE WAS DETECTED ON UNIT 12 DURING BINARY INPUTT2 PROCESSING PROGRAMMER INFORMATION: 1. A KEY VALUE WAS BEING READ 2. THE LAST KEY VALUE READ: 0 FATAL ERROR 0 NO. FORTRAN RECORDS READ

Known Error

CR 31392

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

SSSALTERS - GPFORCE, trncompa - SFM 5423, Incompatible Matrix Multiply If GPFORCE output is requested when using the trncompa alter, then the job may fail with the following error messages:

Description

*** SYSTEM FATAL MESSAGE 5423 (DMPYAD) ATTEMPT TO MULTIPLY INCOMPATIBLE MATRICES COLS ROWS FORM TYPE NZWD DENS TRAILER FOR QG2 IS 101 21 739 2 2 12 77 TRAILER FOR UHDISP IS 102 21 11 2 2 18 7792 TRAILER FOR (NONE) IS 0 0 0 0000 TRANSPOSE FLAG IS 0 0FATAL ERROR There are two possible avoidances: 1. Add "param,ddrmm,-1" to the input file

Known Error

CR 31392 or 2. Replace the following dmap statement mpya

Known Error

CR 31399

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - PARAM,USETPRT, PARAM,USETSEL - Incorrect Decimal Equivalent

Description

the Version 70 and 70.5 Quick Reference guide parameter section indicates that the decimal equivalent of set U6 (to be specified on PARAM,USETSEL for PARAM,USETPRT) is 76108864, it should be 67108864.

Known Error

CR 31422

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation/QRG - XYPLOT, PARAM,CURVPLOT - UWM 979

Description

If XYPLOT commands are specified for plotting in transient or frequency response analysis with grid points on the abscissa, as defined under PARAM,CURVPLOT, then USER WARNING MESSAGE 979 is issued and no plots are output. PARAM,CURVPLOT is applicable only in static and normal modes analysis; i.e., SOLs 1, 3, 5, 14, 15, 16, 101, 103, 105, 106, 114, 115, 144, and 200 even though Table 1 of Section 6 in the Quick Reference Guide indicates that it is applicable in all the structured solution sequences. Table 2 is documented correctly for CURVPLOT. Section 13.3.6 of the Reference Manual is also documented incorrectly with regards to solution sequence applicability.

Known Error

CR 31423

Product

MSC / MD Nastran

Corrected Version Abstract

Interface Elements - GMBNDC - GMCURV Option Results in UFM 6403 The GMCURV option on the GMBNDC entry may incorrectly result in the following fatal message:

Description

*** USER FATAL MESSAGE 6403 (CIFCRV) THE GMBNDC ID = 2 REFERENCED BY GMINTC ID = 5001 IS NOT CONTINUOUS AT GRID ID= 1.

Known Error

CR 31423 Avoidance: The exact cause of the problem is not yet known. The FEEDGE and GRID options may be used instead.

Known Error

CR 31427

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Miscellaneous - Access violation (C0000005) exception encountered When there is an illegal bulk data entry "0" as shown below, then the job may fail in various ways. NT systems have failed with the message "Access violation (C0000005) exception encountered"

Description

0 4602 4603 4604 4605 0 4606 4607

Avoidance: Correct the offending bulk data entries. Known Error

CR 31430

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation/Elements - CMASS1, CMASS2, GPWG - QRG Unclear

Description

The CMASSi elements have provisions for defining a pair of DOFs, although they are often used for point masses. To input a point mass, define only a single DOF. When two DOFs are used a coupled mass matrix is produced. If not input correctly it may cause internal constraints. No checks are made for internal constraints in such elements. The following remarks should be added to the CMASS1 and CMASS2 Quick Reference Guide Descriptions: 7. Scalar elements input coupled mass matrices when the second pair of fields is entered. When uncoupled point masses are desired input only the first pair of fields. When a coupled mass matrix is requested the submatrix added has M on the diagonal, and -M on the off-diagonal. The element is not checked for internal constraints, which is the user's

Known Error

CR 31436

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - PBARL, PBEAML - Missing Documentation

Description

There are undocumented limits in the use of the beam library. For the PBEAML:

Known Error

CR 31436 The beam can have no more than 14 dimensions per station. The total number of dimensions at all stations must be less than 200. The transfer of data with the beam server is limited to 4000 words. None of these limits are exceeded with the MSC beam library, but a user defined beam library could. The data transfer limit would most likely be exceeded when the number of dimensions for a PBARL exceeds 235 (4000 / 17 properties per bar). There is a further limit that the NSM values input on the PBARL and PBEAML must be >= 0. No other property types have this limit.

Known Error

CR 31447

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Aeroelastic Analysis - EPOINT, SOL 145, Multiple Eigenvalue Subcases - UFM 1126 In aeroelastic flutter analysis (SOL 145 only) UFM 1126 as shown below is issued when there are multiple normal mode boundary conditions and the model contains epoints.

Description

UMERGE1 IS ATTEMPTING TO OUTPUT DATABLOCK NAME = GMD which already exists Avoidance: Insert the following DMAP alter: compile sefluttr alter 1 file gmd=save,ovrwrt/god=save,ovrwrt/k4dd=save,ovrwrt $ endalter

Known Error

CR 31452

Product

MSC / MD Nastran

Corrected Version Abstract

Description

P-Elements - GMINTC and GMINTS - Non-Zero Rigid Body Stresses Models that connect curved surfaces with the GMINTC and GMINTS interface elements may experience non-zero stresses due to rigid body motion. These non-zero stresses are caused by the differences in cubic geometry on the dissimilar mesh. Straight interfaces have no such problem, since the geometry is identical.

Known Error

CR 31452

Avoidance: The tolerance TOL on the PINTC and PINTS property entries will generate a warning message for differing geometry, and may be set lower to be more conservative. Known Error

CR 31461

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - PARAM,NQSET - Missing QRG Documentation For part superelements, generalized coordinates can be defined automatically by senqset entries, as documented in the qrg, or by the param, nqset entry. The param method was introduced in Version 69 but has yet to be documented. The documentation follows:

Description

NQSET Default=0 If NQSET>0, and the PARAM entry is in case control, all part superelements that do not contain qset entries, or are not referenced by senqset entries in the main bulk data deck, have NQSET generalized coordinates assigned to them. These qset variables are functionally equivalent to those generated by senqset entries.

Known Error

CR 31463

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Optimization/Design Sensitivity - ANAL=STATICS - UFM 9058 In solution 200 with ANALYSIS=STATICS, if the static loads are null then UFM 9058 will be issued during the sensitivity analysis: THE SOLUTION FOR THE RESIDUAL STRUCTURE DOES NOT EXIST

Description

Avoidance: Insert the following DMAP alter: compile pslgdv alter 'call sela1'(,-1) dbstatus egxp//s,n,noegxp $ if ( noegxp 1.0 Avoidance: On the NLPARM entry increase the NINC field by 1 and restart into the offending subcase. This will change the tolerance calculation.

Known Error

CR 31582

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Miscellaneous - PARAM,DESPCH1 - Punch output with small field format not allwed Bulk Data paramter DESPCH1 can be used to request the format type for the punched output. A negative DESPCH1 requests the small field format while the positive DESPCH1 requests the large field format. However, when an optimization deck specifies the negative DESPCH1 and also specifies the second parameter DESPCH>0, the small field format is ignored.

Description

Avoidance: Apply the dmap alter below: compile nddl=nddl include 'nddl.dat' $ where the nddl.dat is the modified nddl list that includes the following two lines: param,despch =0, type=I, PATH=GEOM,LOCATION=master param,despch1 =6, type=I, PATH=GEOM,LOCATION=master compile desopt alter 'despch' type parm,,i,y,despch1 compi

Known Error

CR 31583

Product

MSC / MD Nastran

Corrected Version 2001

Known Error

CR 31583

Abstract

Acoustic Analysis - METHOD(STRUCTURE), SDFREQ - UFM 4276 EC 1305 In modal frequency response analysis, solution 111, with fluids, if the METHOD(STRUCTURE)=n case control command is missing, the following error will occur:

Description

USER INFORMATION MESSAGE 5222 (SQFREQ) COUPLED SOLUTION ALGORITHM USED. BIOMSG: ERROR 1305 HAS OCCURRED IN ROUTINE ENDPUT , FILE INDEX (FILEX) =0 STATUS = 0 ********* NASTRAN FILE TABLE ********* INDEX LOGNAME STREAM_ID NAME 2 OBJSCR 00000002 /work/30314_42.OBJSCR 3 DBA 00000003 /work/fnd1.dba 4 MAST 00000004 /work/fnd2.mast 6 SCRA 00000006 /home/no4/emc/emc3fnd/fnd5.scra 7 SCRU 00000007 /tmp/fnd6.scru 8 MASTER 00000008

Known Error

CR 31590

Product

MSC / MD Nastran

Corrected Version Abstract

Nonlinear Analysis - Missing Intermediate output on a nonlinear restart run If additional subcases are added in a restart of a solution 106 nonlinear job then there may be missing intermediate output.

Description Avoidance: The problems is under investigation. Other than performing the job as a cold start there is no avoidance. Known Error

CR 31591

Product

MSC / MD Nastran

Corrected Version 70.5.2 Abstract

Description

Postprocessing - DBC, PARAM,POST PARAM,GEOMU,0 - NASTRAN Stops in DBC Module If PARAM,GEOMU,0 is used to suppress the writing of geometry into XDB (i.e. PARAM,0) is in the deck, then the job will stop without message in the DBC module. The log file may contain a message of the form: 1525-001 The READ statement on the file ./s31591.xdb cannot be completed

Known Error

CR 31591 because the end of the file was reached. The program will stop.

Known Error

CR 31608

Product

MSC / MD Nastran

Corrected Version Abstract

Description

File Management Section - ASSIGN, DELETE - DBALL is not Deleted The fms statement ASSIGN includes the DELETE qualifier, which specifies that an existing data base at the start of a run should be deleted, and replaced with a new version. If this qualifier is applied against a MASTER database, it properly deletes the MASTER database. However, MASTERs point to one or more data base members, such as DBALL. The index for these databases are stored on MASTER, so they are useless after MASTER is deleted and they too should be deleted but are not. Aoidance: using assign with delete option applying to all dbsets of the database.

Known Error

CR 31622

Product

MSC / MD Nastran

Corrected Version 70.5.1 Abstract Description

Heat Transfer Analysis - CHBDYE, TA1A - Segmentation Error Heat Transfer models with CHBDYE elements may fail with a segmentation error. Avoidance: There is no avoidance.

Known Error

CR 31636

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Optimization/Design Sensitivity - DESSUB - UFM 6293 incorrectly issued If an attempt to place limits on a global response (such as weight) is applied using a DESSUB command, the program will incorrectly issue UFM 6293.

Description

Avoidance: Global responses (such as WEIGHT) may only be constrained using the DESGLB command. They may not be constrained by the DESSUB command.

Known Error

CR 31655

Product

MSC / MD Nastran

Known Error

CR 31655

Corrected Version 70.5.2 Abstract

Optimization/Design Sensitivity - DOM9 - SFM 4276, EC 3002, EC 1409, EC 31 The message: SYSTEM FATAL MESSAGE 4276, ERROR CODE 1409

Description

can occur in the DOM6 or DOM9 module if there are DRESP2 responses and two or more of the DRESP1 id's invoked by a single DRESP2 are duplicates. Avoidance: Remove the duplicate DRESP1 id's from the DRESP2 entry. It is most likely not the user intent to have duplicated the id's, but it will be permitted once this error is corrected.

Known Error

CR 31662

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Miscellaneous - DBVIEW - Infinite CPU Loop If the view name and the datablock name are identical on the DBVIEW statement, and the datablock is local scratch, then an infinite CPU loop will occur in GNPREP when the view name is used as input to a module. The following input deck demonstrates the problem:

Description

sol AERBG diag 8,24$ compile AERBG $ SUBDMAP AERBG dbview uset = uset ( where peid=1) tabprt uset END $ $ CEND BEGIN BULK ENDDATA

Known Error

CR 31664

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Rigid Elements - RBE3, GP4 - EXIT from GP4, No Fatal Message

Description

The um fields of the RBE3 element contain grid point and component data. A GID-component pair may appear only once in the um fields. When a pair

Known Error

CR 31664 appears more than once, the gp4 modlule takes an exit without producing any diagnostics. The most likely clue that this has happened is to inspect the .f04 file. If the last several modules to run are gp4, append, bcdr,prstum, and exit, a bad rbe3 may be the cause. Avoidance: An avoidance is to check the um fields of all rbe3 entries.

Known Error

CR 31665

Product

MSC / MD Nastran

Corrected Version Abstract

P-Elements - MATGPR - GRIDN Labels Incorrect

Description

When using the MATGPR module to print a matrix for p-elements, the components of the higher-order degrees of freedom represented by the GRIDNs are incorrect. They are labeled T1,T2,T3,R1,R2,R3 followed by garbage, since the number of components may be much higher than 6. They should simply be labeled with integers.

Known Error

CR 31668

Product

MSC / MD Nastran

Corrected Version 70.5.1 Abstract

Description

Optimization/Design Sensitivity - PBEAM - Wrong Answers The Version 70.5 Release Notes state that it is now possible to design properties for the constant cross section PBEAM by referencing the END A fields only on the PBEAM bulk data entry. (Previously, one had to reference the EPT and explicitly design END A and END B). The implementation of this new capability was incomplete in that it does not change the DVPREL2 invoked designed properties at END B. As a consequence, sensitivities of END B responses are most likely incorrect. If an optimization task in undertaken with END B responses, the redesigned structure will provide incorrect analysis results at END B and lead to invalid designs. Avoidance: Either do not use the new feature or do not ask for data recovery at END B in the design task.

Known Error

CR 31671

Product

MSC / MD Nastran

Known Error

CR 31671

Corrected Version 2001 Abstract

Documentation - MODES - Inefficient Processing, Excessive Output

Description

The MODES case control command may be used in all solution sequences as a subcase replicator. The most common and obvious use is in eigenvalue solutions and is demonstrated under the Quick Reference Guide's description of this entry. This command may be of no use in other solution sequences such as transient response and may cause the data recovery processing to be repeated and printed multiple times.

Known Error

CR 31674

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Documentation - PARAM, CB1, CB2, CK1, CK2, CK3, CP1, CP2, CM1, CM2 UFM 6011 Parameters CB1, CB2, CK1, CK2, CK3, CP1, CP2, CM1, and CM2 are incorrectly indicated to be real parameters with a default of 1.0 when they are complex parameters with a default of (1.0,0.). Avoidance: If you use these parameters, define both the real and imaginary terms.

Known Error

CR 31686

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Elements - CQUAD4, CQUAD8, CTRIA3, CTRIA6 - UFM 316

Description

The MCID field on the CQUAD4, CQUAD8, CTRIA3 and CTRIA6 entries cannot be greater than 999999 or else UFM 316 will be generated. However, on the PSOLID and CGAP, coordinate system IDs > 999999 are accepted.

Known Error

CR 31689

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Description

Nonlinear Static Analysis - PGAP - Unnecessary Restriction for Non-Adaptive Gap The adaptive gap element requires that MU2 Ub a compressive force will result. This is unlike the G0 option which flips the element axies if the grids are interchanged.

Known Error

CR 31757

Product

MSC / MD Nastran

Corrected Version 70.5.1 Abstract

Transient Analysis - TRLG - UFM 2025 The following fatal message may be incorrectly encountered in the TRLG module:

Description *** USER FATAL MESSAGE 2025 (TRLG) UNDEFINED COORDINATE SYSTEM ID = 1065353216

Known Error

CR 31757 0FATAL ERROR Avoidance: The error exists in Version 69.1, 70. and 70.5. The best avoidance is to request MSC/NASTRAN Version 70.5.1. The correction of this error has been integrated in to Version 70.0.5 for NASTRAN for Windows. The fixed version remains at 70.5.1 since this error was never an issue for the prior release of NASTRAN for Windows which was based on Version 68.2.

Known Error

CR 31759

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - RELEASE - UFM 6755

Description

The documentation for the RELEASE entry does not state that it is not supported if the model has PART superelements. If a model containing PART superelements contains a RELEASE entry, the program will issue UFM 6755 and terminate the run.

Known Error

CR 31763

Product

MSC / MD Nastran

Corrected Version 70.5.1 Abstract

Description

Eigenvalue Analysis - EIGRL, READ - SFM 7340 (LNNHERR), LNNDRVD In the rare case that Lanczos shifts directly on a mode, the new lanczos shift logic in MSC/NASTRAN Version 70.5 may encounter an error which may cause the job to fail with messages similar to those below instead of performing a new shift. *** USER WARNING MESSAGE 4698 (DCMPD) STATISTICS FOR DECOMPOSITION OF MATRIX (NONE) . THE FOLLOWING DEGREES OF FREEDOM HAVE FACTOR DIAGONAL RATIOS GREATER THAN 4.85302E+11 OR HAVE NEGATIVE TERMS ON THE FACTOR DIAGONAL. *** SYSTEM FATAL MESSAGE 7340 (LNNHERR) process error reported by subroutine LNNP2CD see LNNP2CD abstract (ier = -729) *** SYSTEM FATAL MESSAGE 7340 (LNNHERR) warning reported by subroutine LNNDRVD see LNNDRVD abstract (ier = 729) Avoidance: The simplest, most guaranteed avoidan

Known Error

CR 31769

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Online Encyclopedia - RANDPS - RANDPS is Missing from Index The RANDPS index is missing from the Table of Content section of the online documentation. The actual RANDPS entry is in the online CD.

Description Avoidance: Click on the RANDT1 button and scroll one page up to find the RANDPS entry. Known Error

CR 31775

Product

MSC / MD Nastran

Corrected Version 70.5.1 Abstract

Utilities - PLOTPS - Fail with UNRECOVERABLE library error On all Cray platforms, PLOTPS will fail with the following error message lib-1171 plotps: UNRECOVERABLE library error An output list item is incompatible with its data edit-descriptor.

Description

Encountered during a sequential formatted WRITE to an internal file (character variable) Error initiated at line 647 in routine '_wrfmt'. Abort Beginning of Traceback: Interrupt at address 74547a in routine '_lwp_killm'. Called from line 16 (address 75571a) in routine 'raise'. Called from line 92 (address 15347c) in routine 'abort'. Called from line 59 (address 352112a) in routine '_ferr'. Called from line 647 (address 424651c) in routine '_wrfmt'. Called from line 232 (address 343053c) in routine '_xfer_iolist'. Called from line 396 (address 423231c) in routine '_FWF'.

Known Error

CR 31778

Product

MSC / MD Nastran

Corrected Version GL Abstract

Nonlinear Analysis - DECOMP - UWM 4698 Does not Identify Degrees of Freedom When running sparse decomposition in solution 106, the message:

Description

USER WARNING MESSAGE 4698, STATISTICS FOR DECOMPOSITION OF MATRIX ***. THE FOLLOWING DEGREES OF FREEDOM HAVE FACTOR DIAGONAL RATIOS

Known Error

CR 31778 GREATER THAN *** OR HAVE NEGATIVE TERMS ON THE FACTOR DIAGONAL" does not list the grids/dofs corresponding to the negative diagonal terms.

Avoidance: Run the job with SPARSE=1 to identify the negative diagonal terms.

Known Error

CR 31784

Product

MSC / MD Nastran

Corrected Version 70.5.2 Abstract

Description

Nonlinear Analysis - CBUSH, PBUSHT - Missing CBUSH STRESS/FORCE Output In a SOL 106 run, if a CBUSH element is present using the nonlinear forcedeflection feature (KN on the PBUSHT entry) and there is no other nonlinear material present, then the STRESS/FORCE output for the CBUSH element may be missing. This has been observed on some, but not all problems. Avoidance: Add param,lgdisp,1 to the input file. A safer avoidance would be to define a dummy rod or quad4 element with an associated MATS1 entry

Known Error

CR 31787

Product

MSC / MD Nastran

Corrected Version 70.5.1 Abstract

Description

Heat transfer Analysis - CHBDYG, CHBDYP - Wrong Answers If the user has nonunique CHBDYP element ID that are the same as a CHBDYG element ID, the NASTRAN program does not know which CHBDYx element ID should be used in the convection calculation. The fix will allow the program to flag the non-unique CHBDYP and CHBDYG id's in the gp2 module. Avoidance: Change the conflicting CHBDYP and CHBDYG element id's so that they are unique.

Known Error

CR 31796

Product

MSC / MD Nastran

Corrected Version 70.5.1

Known Error

CR 31796

Abstract

P-Elements - ADAPT, EPSTOL - Wrong Answers When a shell or beam p-element is omitted from the error analysis because of the EPSTOL parameter on the ADAPT bulk data entry, all subsequent shell and beam p-elements will also be omitted.

Description Avoidance: An avoidance is to set the EPSTOL parameter to zero on the ADAPT entry so that no elements are omitted. Known Error

CR 31801

Product

MSC / MD Nastran

Corrected Version 70.5.1 Abstract

Description

P-Elements - ADAPT, EPSTOL - Poor Answers If a shell or beam p-element has a low stress at one grid, the element may be omitted from the error analysis because of the EPSTOL parameter on the ADAPT bulk data entry. The element should not be omitted unless all grids have a low stress. Avoidance: An avoidance is to set the EPSTOL parameter to zero on the ADAPT entry so that no elements are omitted.

Known Error

CR 31804

Product

MSC / MD Nastran

Corrected Version 70.5.2 Abstract

Thermal Loads - PSHELL - Wrong Stresses

Description

If the T1 and T2 fields are specified on the TEMPP1 entry and the MID1 field on the PSHELL record is left blank, then the calculated element stress will be wrong. Avoidance: Specify the MID1 field on the PSHELL entry.

Known Error

CR 31814

Product

MSC / MD Nastran

Corrected Version 70.5.1 Abstract

Matrix Methods - MPYAD Method 1 NT/T Storage 1 - Memory Allocation Error

Description

Runs on aix platforms with large multiply-adds, in which Method 1 NT/T Storage 1 is selected, may unexpectedly run out of virtual memory. Encountering the error depends on such variables as the size of the problem and the amount

Known Error

CR 31814 of system paging space available on the machine. When the error occurs, the run terminates with the following error message: SYSTEM ERROR MESSAGE (gotsig33): SYSTEM RAN OUT OF PAGING SPACE. Avoidance: Note that when this error is encountered, increasing the memory allocation with the NASTRAN mem parameter will not generally avoid the problem. The avoidance is to increase the system paging space.

Known Error

CR 31817

Product

MSC / MD Nastran

Corrected Version 70.5.2 Abstract

Dynamics - PARAM,VMOPT,1 - Inefficient Processing If PARAM,VMOPT,1 is specified then the MGEN module is executed twice. Also, if component modes are not requested then the fluid mass should not be computed at the g-set level; in other words, PARAM,VMOPT,1 should be ignored. Avoidance: Insert the following DMAP alter:

Description

Known Error

compile semrm alter 'mgen '(,-1) if ( vmopt=0 or not((DYNRED=-1 or METHOD=-1) and noqset>-1) ) then $ alter 'vmopt'(2),'' alter 'call mgen1'(,1) endif $ NOMGEN>-1 alter 'PURGEX \/mvaa','' dbstatus mej//s,n,nomej $ if ( nomej>0 ) then $ alter 'mpyad meo'(,-1) CALL SEGOA uset,GOT,GOQ/GOA/NOOSET/NOQSET/NOTSET $ alter 'mpyad meo'(,1) else $ purgex /mea,,,,/-1 $ endif $ nomej>0 alter 'ENDIF \$ NOMGEN','' compile semg alter 'vmopt'(2),'' type db uset0 $ PARAML CASES//'DTI'/-1/150//S,N,DYNR CR 31832

Known Error

CR 31832

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Description

Miscellaneous - PARAM,USETPRT - Wrong Sort If there is a user defined degree of freedom set (USET, USET1), and row sorting is selected (PARAM,USETPRT,0 or 10), then the uset print tables will not be sorted in ascending order, but will be in a random order. Avoidance: Select 'Column'(val=1 or 11) or 'Row and Column'(val=2 or 12) sort on the PARAM,USETPRT entry.

Known Error

CR 31842

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Miscellaneous - INCLUDE, SOL - UFM 443 If the SOL executive statement points to a user-written dmap, and the dmap is inserted in front of the SOL statement using the include command, then the job may fail with the following messages on some machine.

Description

*** USER FATAL MESSAGE 443 (DBALOC) THE SUBDMAP MAIN REFERENCED BY THE SOL, LINK OR COMPILE STATEMENT WAS NOT FOUND ON THE MSCOBJ DBSET. Avoidance: Either move the SOL statement before the include command or insert the dmap into the actual file instead of using the include command.

Known Error

CR 31844

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Description

Aeroelastic Anaslysis - AEKX, AESMETH=ITER - Slow Convergence When using AESMETH=ITER or AESMETH=AUTO in SOL 144 and the displacement and force splines are not the transpose of one another (e.g., if the USAGE field is not BOTH on all SPLINEi entries), the iterative aeroelastic solution may converge slowly or even fail to converge. This is caused by an error in the AEKX subdmap in which it was mistakenly assumed that the splines were transposes of one another (as they had been required to be prior to Version 70.5). If the force and displacement splines are transposes of one another, this problem does not occur. Avoidance: An avoidance is to use identical FORCE and DISP splines (which was a requirement prior to Version 70.5). Another avoidance is to apply the following alter to Version 70.5:

Known Error

CR 31844 compile aekx list noref $ $ fix errors due to mqg' an

Known Error

CR 31849

Product

MSC / MD Nastran

Corrected Version 70.5.1 Abstract

Submittal - nastran.ini on Windows NT - Application Error If the last line of the nastran.ini file (found in the $MSC_BASE\msc705\\ directory) is not terminated, then the NASTRAN command will fail with the following message generated by Windows: An application error has occured and an application error log is being generated nastran.exe Exception: access violation (0xc0000005), Address: 0x0041c608

Description

This error is easily created with Notepad. Note that the ini file is now only used to set a very small number of keywords, e.g., msc_base, and version. In most other cases the rcf files are now used. If other keywords are set in the nastran.ini file they are ignored.

Avoidance: Put an end-of-line at the end of the last line in the nastran.ini file. Known Error

CR 31855

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Documentation - CGAP, PARAM,G - Unreasonably Large Damping With penalty CGAP (default), W3 damping can become excessive because of large CGAP penalty stiffness. This is a limitation that should be documented under the CGAP entry.

Description

Avoidance: When gap elements are used in nonlinear transient analysis, param,g damping should be avoided. Damping should be specified on the MATi entries and PARAM,W4 set.

Known Error

CR 31884

Product

MSC / MD Nastran

Known Error

CR 31884

Corrected Version 70.7 Abstract

Description

Optimization/Design Sensitivity - ADD5, PARAM, DSNOKD - UFM 5423 The message "USER FATAL MESSAGE 5423" indicating an incompatible matrix multiple is output from the ADD5 module in SOL 200 when PARAM DSNOKD is non-zero and there are multiple subcases that have active buckling design constraints. Avoidance: Set DSNOKD to 0.0 or restrict the buckling design task to a single subcase.

Known Error

CR 31885

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Description

Rigid Elements - RBE3 - UWM 7343 Diagnostic USER WARNING MESSAGE 7343 for the RBE3 element appears, properly, when an RBE3 element has inadequate connectivity and is approaching singularity. It may also appear for a stable element when there is a large distance between the grid points to which it attaches. This is because the test used to measure singularity is not independent of the units of measure of the model. A test model of an rbe3 connecting 4 grid points in a square pattern to a point at their center does not cause the message when the points are 100 units apart, but does cause the message when they are 10,000 units apart on certain computer types. Avoidance: The criterion used to print this message is that the computational zero ("error value") associated with its use is greater than 1.E-10. This conserva

Known Error

CR 31890

Product

MSC / MD Nastran

Corrected Version 70.5.2 Abstract

Description

Rigid Elemets - RBE3 - UFM 2038, Only one illegal RBE3 found per run All bad rigid elements should be found and identified in a single execution. However, the RBE3 is an exception. It causes the program to stop after the first bad element is found. This is a particular problem with Version 70.5 because improved logic for detecting singular RBE3 elements was introduced in this version, and the

Known Error

CR 31890 program may fail RBE3 elements that earlier versions passed. Avoidance: The error has been corrected in Version 70.5.2. Another avoidance is to run the model in Version 70 with param, checkout yes present. This makes tests on the model including equibrium tests on the rigid element constraint matrix. Elements which will pass tests in Version 70 but fail with singularity messages in Version 70.5 are likely to show poor equilibrium properties in the para

Known Error

CR 31891

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - GPSTRESS - No Printout for Midside Nodes

Description

MSC/NASTRAN does not printout GPSTRESS for midside nodes. This limitation is documented in the Application Manual but since that manual is no longer current a remark should be added to the Quick Reference Guide.

Known Error

CR 31898

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Frequency Response - FREQ - UWM 6498 In a frequency response analysis run (SOL 108 and 111), if the FREQ Case Control command does not exist, then the job will terminate with the following unclear error messages on some machines.

Description

*** USER WARNING MESSAGE 6498 (MsgGetStr) Message number is not found PROGRAMMER INFORMATION: Check call to MSGPOP from FRLG with the message number 3031 Severity is USER WARNING Parameter 1 is 0 Parameter 2 is FRL Parameter 3 is FRRD USER ACTION: Please contact MSC Client support 0FATAL ERROR On other machines, the job may terminate with a signal 11 error in the log file. Avoidance: Add the appropriate FREQ case control command.

Known Error

CR 31906

Product

MSC / MD Nastran

Corrected Version 70.5.2 Abstract

Nonlinear Analysis - DBC - UFM 4551 If a nonlinear analysis fails to converge and PARAM,POST,0 is set, the job will issue fatal messages indicating that the analysis has not converged but then will continue and will fail in the DBC module with a machine dependent message. An example of the messages are:

Description

*** USER INFORMATION MESSAGE 6194, *** STOPPED ITERATIONS DUE TO REACHING MAXIMUM ITERATION LIMIT WITHOUT CONVERGENCE *** *** USER INFORMATION MESSAGE 6193, *** MAXIMUM NUMBER OF BISECTIONS OR MINIMUM LOAD STEP HAS BEEN REACHED. *** USER FATAL MESSAGE 4551, *** STOPPED PROBLEM DUE TO FAILED CONVERGENCE ^^^ USER INFORMATION MESSAGE 9005 (NLSTATIC) ^^^ THE SOLUTION FOR THE LAST CONVERGED LOOPID= 85 IS SAVED FOR RESTART ***** RECEIVED SIGNAL 8, ABORTING ... BIOMSG:

Known Error

CR 31919

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Installation - Sun/Solaris - fatal : libsunmath.so.1: can't open file errno = 2 For Sun SuperSPARC V70.5 and v70.6 and Sun UltraSPARC V70.0.3 Clients only, If you do not have a Fortran compiler on your system, you may receive the following error message in the LOG file when you attempt to run MSC/NASTRAN:

Description

ld.so.1: /msc705/solaris/analysis: fatal : libsunmath.so.1: can't open file errno = 2 This error occurs when the system cannot find the "libsunmath" dynamic library. This error is corrected on the MSC/NASTRAN V70.5.1 (r2) CD-ROM. You can also obtain the missing libraries from your MSC representative or directly from MSC's Web site at the URL:

Known Error

CR 31919 ftp://ftp.macsch.com/pub/mscproducts/NASTRAN/V70.5/solaris/libsunmath.so.1 Once you have obtained the file, please copy it to the solaris architecture directory, i.e.,

Known Error

CR 31931

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Acoustics - ACMODL, CTETRA, CTRIA3, GP5 - SFM 6169 Some models with TRIA3 structural elements and TETRA fluid elements at the fluid/structure interface using IDENT method on the ACMODL bulk data entry fail in the GP5 module with a message similar to:

Description

*** USER FATAL MESSAGE 6169, FOUND TWO OR MORE STRUCTURAL GRID POINTS WITH IDENTICAL COORDINATES WHICH LIE ON THE FLUID/STRUCTURE BOUNDARY. USER ACTION: CHECK GRIDS AND/OR SET1 CARDS WHICH BELONG TO PANEL OR ACMODL CARDS. GRID ID = 12 GRID ID = 101979 ^^^ USER WARNING MESSAGE 9031 (ERRPH1) - NOGO ENCOUNTERED IN SUBDMAP SEMG This message is in error since one of the referenced structural grids is really a fluid grid. Abitrary changes to the model can make it run or not run. Avoidance: Use the DIFF method on the ACMODL

Known Error

CR 31933

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation/DMAP - MATGEN Option 5 - DMAP Module Dictionary

Description

The documentation for MATGEN option 5 states that the parameter p5 may

Known Error

CR 31933 be used to select pseudo-random or non-repeating random numbers, but the equation used is incorrect. It states that if P5= 0, Default = 0) R1, R2, R3 Rectangular components of the rotation vector R. The vector will pass through G, please see remark 14. (R1**2 + R2**2 + R3**2 > 0.0) Remark 14. If CID is not a rectangular coordinate system, RFORCE will treat it as if it were a rectangular system when d Known Error

CR 31958

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Memory Management - REIGL, GPFDR - SFM 4275 and SFM 4276

Known Error

CR 31958 On a large model, it has been observed that the job may fail in REIGL or GPFDR with the following unclear messages:

Description

*** SYSTEM FATAL MESSAGE 4275. DURING A READ OPERATION, UNIT = 26, DATA BLOCK=NUMERIC , A BLOCK NUMBER CHECK CONDITION OCCURRED. ( IONAST CODE= 304) 0*IONAST* err 304 pid,name,b+1,z4(b+1),nxtblk,pbknbr= 0 118 62402415 0 3377 5912 BIOMSG: ERROR 304 HAS OCCURRED IN ROUTINE IONAST , FILE INDEX (FILEX) =0 STATUS = 0 The exact cause of this error is currently unknown. MSC has been unable to obtain the input file that shows this error due to the confidentiality of the input file. Avoidance: Increasing memory cured this particular problem.

Known Error

CR 31966

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Nonlinear Analysis - CBUSH, CELAS1, CELAS2, MATHP - UWM 6286 in ZREAD If nonlinear stress output is requested for CBUSH, CELAS1, and CELAS3 elements which reference PBUSHT and PELAST in nonlinear analysis then UWM 6286 will be issued. This also occurs for hyperelastic element grid point output. Avoidance: Insert and/or replace the following changes into nddl.dat under DATABLK OES:

Description

OR,40,{ Bush1d } EITHER,BACK(FCODE)=0,{ Real } FE,RS,{Element Force} UE,RS,{Axial Displacement} VE,RS,{Axial Velocity* } S,RS,{Axial Stress*} E,RS,{Axial Strain*} EP,RS,{Plastic Strain*} FAIL,I,{Failed Element Flag} OR,1,{ Real / Imaginary } FER,RS,{Element Force} UER,RS,{Axial Displacement} SR,RS,{Axial Stress*}

Known Error

CR 31966 ER,RS,{Axial Strain*}

Known Error

CR 31970

Product

MSC / MD Nastran

Corrected Version GL Abstract

Superelements - CSUPEXT Ignored if no Elements Exist in a Superelement

Description

If there are no elements inside a superelement, but there are interior points, and CSUPEXT entries are used to define the exterior points, the CSUPEXT entries will be ignored. Avoidance: Add PLOTEL elements between interior and exterior points.

Known Error

CR 31980

Product

MSC / MD Nastran

Corrected Version 70.5.1 Abstract

Nonlinear Analysis - NLCOMB - Traceback If a problem has BEAM, BAR, or BEND elements and thermal loads in a nonlinear solution sequence (106 and 129), the job may fail in module NLCOMB. This error first occurred in Version 70.5. This has been observed only on the Cray, but might occur on other systems. On the CRAY the following traceback was encountered:

Description

Beginning of Traceback: Called from line 42 (address 15517150b) in routine 'TRBK'. Called from line 39 (address 132053d) in routine 'RECOVR'. Called from line 112 (address 140623d) in routine 'sysrcv'. Called from address 15237006a in routine '__handlr'. Called from address 5616165c in routine 'NLCWRK'. Called from line 126 (address 5607145c) in routine 'NLCOMB'. Called from line 90 (address 10632226d) in routine 'XSEM15'. Called from line 363 (addr

Known Error

CR 31982

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

SSSALTERs - checka.v70 - UFM 13

Description

In the checka.v70 and checka.v705 alters, there are two lines which exceed 80 columns. If these alters are pasted into the data file, the line will wrap in many editors, and cause the following fatal message: 0*** USER FATAL MESSAGE 13 (XGPIDG )

Known Error

CR 31982 ERROR IN DMAP INSTRUCTION Q-SET INSTRUCTION NO. 50 DMAP INSTRUCTION NOT IN MODULE LIBRARY. Avoidance: Shorten the comments following the DMAP instructions "type db,aagds,ptga $", and "upartn uset0,aagds/ptga,,,/'G'/'A'/'S'/1 $". Another option is to avoid pasting the file in, but instead use the include statement.

Known Error

CR 31986

Product

MSC / MD Nastran

Corrected Version 70.5.2 Abstract

Superelements - DBDN DBset Too Large The DBDN DBset is larger in V70 and V70.5 than in earlier versions of MSC/NASTRAN. The increased size is due to several data blocks which are generated during dynamic reduction being incorrectly stored on DBDN. The only effect of this error is an increase in the DBDN Dbset disk usage. Avoidance: Insert the following DMAP alter:

Description

Known Error

compile semr3 alter 'call cmpmode' type parm,nddl,char8,n,dbupx,dbdnr1 $ type parm,,char8,n,dbtmp $ dbtmp=dbdnr1 $ dbdnr1=dbupx $ alter 'call sesum' dbdnr1=dbtmp $ compile sekr alter 1 type parm,nddl,char8,n,dbupx,dbdnr1 $ type parm,,char8,n,dbtmp $ dbtmp=dbdnr1 $ dbdnr1=dbupx $ alter 'end \$'(,-2) dbdnr1=dbtmp $ compile semrm alter 'mvaa'(2,-1) type parm,nddl,char8,n,dbupx,dbdnr1 $ type parm,,char8,n,dbtmp $ dbtmp=dbdnr1 $ dbdnr1=dbupx CR 31990

Known Error

CR 31990

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - PBUSH1D

Description

The MSC/NASTRAN Quick Reference Guide for Version 70.5 incorrectly states that SHOCKA, CVT, IDTS, IDETS, IDETSD, TYPE, IDT, IDTTU, IDTDV are required on the PBUSH1D entry. These fields may be required based on values in other fields and options selected, but are not mandatory.

Known Error

CR 32011

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Documentation - PBUSH - Element Property Direction Not Described The documentation for PBUSH does not say which coordinate system the "directions 1 through 6" refer to. These directions refer to the element coordinate system.

Known Error

CR 32014

Product

MSC / MD Nastran

Corrected Version 70.5.2 Abstract

Transient Analysis - NLRGAP, TRD1 - Poor Answers, Traceback

Description

Input files using the NLRGAP in SOL 109 may fail with a floating point exception on NT platforms or may issue a traceback in the TRD1 module, routine tabld on SGI R8000/R10000 systems. The error is caused by the table look up for the coefficient of friction for the NLRGAP. All 32 bit, short-word, machines will return an incorrect value for the coefficient of friction; however, this is not likely to have a significant effect on the results of most problems.

Avoidance: Run the problem in solution 129. A different error with similar symptoms may also be encountered in the same area of the code, please see error number 32685. Known Error

CR 32015

Product

MSC / MD Nastran

Corrected Version 2001

Known Error

CR 32015

Abstract

Documentation - Release Guide - NLRGAP Does Not Work in Solution 112.

Description

The MSC/NASTRAN Release Guide for Version 70.5 incorrectly states that the NLRGAP element works in SOL 112. The NLRGAP does not work in this solution, but it does work in SOL 9.

Known Error

CR 32016

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

GAP Constraints - PARAM,CDITER - UWM 9096, Wrong Answers If the iterative solution for GAP constraints in SOL 101 does not converge, a warning message is issued (9096), indicating that the solution has not converged; however, the results for displacements, etc. are still output.

Description

^^^ USER WARNING MESSAGE 9096 (CSTRDISP) ^^^ CONSTRAINED DISPLACEMENT ITERATIONS FAILED, ITERATION LIMIT LOAD CASE =1 Avoidance: If warning message 9096 is issued, do not use the results. Increasing the value of CDITER may help the problem to converge.

Known Error

CR 32022

Product

MSC / MD Nastran

Corrected Version 70.5.1 Abstract

Miscellaneous - NLRGAP - Incorrect TPL Problem The tpl test deck nlrgap.dat referred is not the problem described in the Version 70.5 Release Guide. The tpl deck nlrgap.dat has been replaced with the correct input deck on the Version 70.5.1 r2 cd. A listing of the correct input follows:

Description

$ shaft1x.dat $ radial gap, .002 clearance, contact stiffness = 1.e6 constant $ example: rotating load on cantilevared shaft $ 40" shaft, circular x-section, 2" diameter shaft $ 10" diameter rotor $ 15 hz. imbalance sol 129 time 80 cend title= 15 hz. rotating imbalance, radial gap

Known Error

CR 32022 set 1 = 9,10 set 2 = 1,8 set 3 = 1001,1002 $sdisp=3 $ epoint displacements (relative displacements) disp(plot) = 1$ NLRGAP grid displacements force(plot) = 2 nlload=1 $ NLRGAP load output nonlinear = 200 $ NLRGAP set ID tfl=900 $ transfer function ID fo

Known Error

CR 32047

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Optimization/Design Sensitivity - Wrong Answers with Material Damping Material damping defined on a material bulk data entry is ignored in an adjoint sensitivity analysis. Avoidance; If damping is a constant across all materials, param,g may be used. Otherwise the adjoint method needs to be avoided by forcing the direct sensitivity method using the following alter:

Description COMPILE DESCON alter 'dsad'(,-1) $ type parm, ,logi,n,hold $ hold = pexist $ pexist = true $ alter 'dsad' pexist = hold $ Known Error

CR 32070

Product

MSC / MD Nastran

Corrected Version 70.5.2 Abstract

Description

Differential Stiffness - SOLs 103, 107-112 - Wrong answers If QSETi, SEQSETi, or SENQSET entries are used to compute component modes in SOLs 103 and 107-112 and differential stiffness is requested with the STATSUB Case Control command, then the differential stiffness will not include the effects of the q-set degrees-of-freedom. Avoidance: Insert the following DMAP alter which is valid for Version 70.5 only:

Known Error

CR 32070 compile sekdr $ this alter is for Version 70.5 only alter 'call segoa','' type db goq $ CALL SEGOA USET,GOT,goq/GOAT/NOOSET/NOQSET/NOTSET $ endalter

Known Error

CR 32073

Product

MSC / MD Nastran

Corrected Version 70.5.2 Abstract

Superelements - Partitioned SE - Wrong Answers or Fatal Messages If scalar points are defined in a partitioned superelement and the scalar points are also defined as exterior to the superelement (e.g.; QSETi) then the run may produce wrong answers and/or issue a fatal message. This error can also occur using the SENQSET entries. Avoidance: Insert the following DMAP alter:

Description compile phase0 alter ',SILS,VGFS' delete /vgfs $ alter ',SILS,VGFS'(2) delete /vgfs $ endalter Known Error

CR 32074

Product

MSC / MD Nastran

Corrected Version 70.5.2 Abstract

Superelements - Data Recovery for Externals in SOLs 110-112 - UWM 9098 Performing data recovery using external superelements in SOLs 110, 111, and 112 with SEBULK type external superelements will result in user warning message 9098 indicating that the data necessary to perform data recovery is not available. The run will then fail in an unexpected manner. Avoidance : Include the following DMAP alter in the run which performs the residual structure solution

Description compile super3 alter 'call extdrout'(4),'' if ( extdrout' ' ) then $ if ( app1='mmreig' ) then $ call extdrout uls,ol1m,eqexins,maps/ dum/app1/' '/true $ call extdrout uh2,ol1r,eqexins,maps/

Known Error

CR 32074 dum/app/soltyp/true $ else $ call extdrout uls,ol1m,eqexins,maps/ dum/app1/soltyp/true $ endif $

Known Error

CR 32080

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Complex Eigenvalue Analysis - CEAD - SFM 4276, EC 1605

Description

On the SGI, complex Lanczos eigenvalue analysis may produce the unexpected system fatal message 4276 error code 1605. This appears to be caused by insufficient memory for the CEAD module. Avoidance: In most if not all cases experienced to date, increasing the memory has allowed the runs to run successfully.

Known Error

CR 32087

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Frequency Response - TLOADi - Wrong answers TLOADi entries are ignored in direct frequency response (SOLs 8, 11, and 108). Avoidance: Insert the following DMAP alter in SOL 108:

Description

compile sedfreq alter 'CASE CASErs' type parm,,logi,n,fourier $ paraml dynamics//'bulk'//////'tload1'/s,n,tload1/ 'tload2'/s,n,tload2 $ PARAML CASEF//'DTI'/-1/38//S,N,TSTEP $ fourier=(tstep=-1 and (tload1=-1 or tload2=-1)) $ alter 'call freqrs','' CALL freqrs CASEF ,USETD ,DLT ,FRL ,trl , rpd ,DIT ,EST ,cstms ,mpts , bgpdts ,gpsnts ,GPECT ,SILS ,edts , ckdd ,cmdd ,cbdd ,k4dd , , , , ,sild ,ditid , vafs ,rgdfd ,rsgg ,rmgg ,ppf ,

Known Error

CR 32091

Product

MSC / MD Nastran

Known Error

CR 32091

Corrected Version 70.7 Abstract

Nonlinear Analysis - PCOMP, STRESS, STRAIN, PARAM,POST,0 - Missing XDB Output If PARAM,LGDISP,>0 and PARAM,POST,0 is specified in SOL 106, then laminar stress and strain output is missing from the .xdb file. Avoidance: Insert the following DMAP alter:

Description

compile nlstatic alter 'oescp,oestrcp' file oescpr=append/oestrcpr=append $ append oescp,/oescpr/2 $ append oestrcp,/oestrcpr/2 $ alter 'OUTPUT2 oesnlxr' IF ( POST=0 ) then $ DBC OEScpr,,,,,,,,,,,,,,,,,,,// 'OESC'/'CASECC'/'OL'////////////////// -1/DBCPATH/S,N,CP/app//GEOMU/LOADU/POSTU/ DBCDIAG/DBCCONV/DBCOVWRT $ DBC OEStrcpr,,,,,,,,,,,,,,,,,,,// 'OESC'/'CASECC'/'OL'////////////////// -1/DBCPATH/S,N,CP/app//GEOMU/LOADU/POSTU/ DBCDIAG/DBCCONV/DBCOVWRT $ endif $ post=0 endalter

Known Error

CR 32093

Product

MSC / MD Nastran

Corrected Version 70.5.1 Abstract

Aeroelastic Analysis - CSSCHD - UFM 311 (IFPDRV) If a subcase invokes multiple CSSCHD bulk data entries, the user fatal message shown below incorrectly states that the CSSCHD ID's must be unique.

Description

*** USER FATAL MESSAGE 311 (IFPDRV) NON-UNIQUE FIELD 2 ON BULK DATA ENTRY CSSCHD 10 SORTED ENTRY COUNT = 153 Avoidance: There is no avoidance other than to limit the scheduled control surface functionality to a single control surface for each subcase.

Known Error

CR 32094

Product

MSC / MD Nastran

Known Error

CR 32094

Corrected Version 70.7.2 Abstract

Optimization/Design Sensitivity - Nonlinear Trim Analyis - BIOMSG: ERROR 100 Version 70.5 added a basic capability to perform nonlinear static aeroelastic trim analysis. This capability is not available in SOL 200 for sensitivity analysis and its use results in a nondescriptive fatal message such as

Description

BIOMSG: ERROR 100 HAS OCCURRED IN ROUTINE PACK Avoidance: Either linearize the static aeroelastic trim analysis or do not attempt to perform this type of sensitivity analysis. Version 70.7.2 has been corrected to provide a meaningful message.

Known Error

CR 32098

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation, QRG - PSHELL, remark # 14 - typographical error

Description

There is a typographic error for Remark 14 of the PSHELL entry in the Version 70 and 70.5 Quick Reference Guide. The term (Ts)10**8(Ts) should simply be 10**8 instead.

Known Error

CR 32099

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Postprocessing - PARAM,POST,-2 - Multiple Geometry Written to OUTPUT2 File If multiple boundary conditions are specified in a normal modes analysis and param,post,-2 is set, the geometry data blocks are written to the output2 file in each subcase rather than just once. This unnecessarily increases the size of the output2 file.

Description

Avoidance: Specify PARAM,OGEOM,NO in all but the last subcase or insert the following DMAP alter: compile super3 alter 'call out2geom'(,-1) type parm,nddl,i,n,ncase $ if ( ncase-1) $ ENDALTER

Known Error

CR 32112

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Miscellaneous - MSCACT Missing Summary Output The MSCACT utility delivered with MSC/NASTRAN Version 70.5 on the UNIX and Windows NT systems has an error that disables the "standard" output summary. If one of the alternate summaries is selected via the "summary" keyword, the correct detail lines will be generated, but the total line will be missing.

Description

This error can be corrected by changing the following lines in the /msc705/util/mscact.c source file and rebuilding the MSCACT utility as described in Section 6 of the "Configuration and Operations Guide" for you operating system. NOTE: This error does not affect the accounting logger functions. The changes are: Change line 1339 from if( total == -1 && !strcmp( p, TOTAL_LABEL ) ) to if( total == EOL && !strcmp( p, TOTAL_LABEL ) )

Known Error

CR 32113

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Miscellaneous - DMIG, DMI - Poor Messages

Description

The messages encountered when there is an error on a DMIG or DMI entry do not point to the location of the error. This can make it almost impossible to locate the error in a large matrix input.

Known Error

CR 32116

Product

MSC / MD Nastran

Corrected Version 70.5.1 Abstract

Miscellaneous - ISHELL - Program Called by ISHELL Not Found If the program called by the ISHELL module has a name with fewer than 8 characters without including the extension, the module will not search properly for the extension. For example, the file named "EFM.EXE" will be found if the name "EFM.EXE" is entered, but will not be found if the name "EFM" is entered.

Description

Avoidance: Use 8 characters in the filename if you do not include the extension. A related error that may occur on Windows NT if a 16-bit executable is to be run. If ISHELL processing fails with an "UNABLE TO CREATE A NEW PROCESS" error, specifying the standard NT command processor as the processor to be used may solve the problem. That is, setting the MSC_ISHELLEXT environment variable to exe#cmd, either in the System/Environment Control Panel tab or by a command line set opti

Known Error

CR 32125

Product

MSC / MD Nastran

Corrected Version 70.5.1 Abstract

Submittal - DBINIT - Long filenames on SGI

Description

If a very long filename is used, either via the job datafile pathname, the dbs or out keywords, or an ASSIGN statement, the job may fail without any messages in the F06, F04, or LOG files. A clue to this error may be the termination of the job in the DBINIT module (as indicated in the F04 file) or incomplete reports for the "SUMMARY OF FILE ASSIGNMENTS" or "SUMMARY OF PHYSICAL FILE INFORMATION" or "SUMMARY OF PHYSICAL FILE I/O ACTIVITY"

Known Error

CR 32125 tables. Avoidance: Reduce the lengths of the longer pathname components. A pathname component is either a directory name (i.e., the text between slashes) or the actual filename part.

Known Error

CR 32127

Product

MSC / MD Nastran

Corrected Version 70.5.1 Abstract

Aeroelastic Analysis - AELINK, CSSCHD - Wrong Answers

Description

If AELINK and CSSCHD entries appear is the same subcase in a static aeroelastic analysis, wrong answers are produced. Avoidance: There is no avoidance.

Known Error

CR 32134

Product

MSC / MD Nastran

Corrected Version

70.5.1

Abstract

Installation - SGI IRIX64 Only When trying to run Version 70.5 on SGI IRIX 64 systems the following error message may appear in the command window: 3708:/msc/msc705/irix64/analysis: rld: fatal error: cannot successfuly map soname 'libcomplib.sgimath.so' under any of the filenames < then a list of library files follows >.

Description

Avoidance: If the client does not have a complete set of sgi math libraries they will need to get a /usr/lib64/mips4/libcomplib.sgimath.so from MSC. This can be found at the following locations: On the web at: ftp.macsch.com/pub/msc-products/NASTRAN/V70.5/irix64 filename: libcomplib.sgimath.so or the following computer file on MSC's net: /net/oberon/oberon/disk1/msc705/unix/msc705/irix64/libcomplib.sgimath.so

Known Error

CR 32135

Known Error

CR 32135

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Description

Complex Eigenvalue Analysis - CEAD - Missing Left Hand Vectors The new CEAD module option for the CLAN method in Version 70.5 will produce both left and right hand eigenvectors. However, if there are less than three DOFs in the problem only the right hand vectors are output. Avoidance: An avoidance is to add a third DOF, uncoupled, if necessary.

Known Error

CR 32136

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation/QRG - PARAM,CURVE - Incorrect Equation The documentation for PARAM,CURV in the Quick Reference Guide indicates that if:

Description

| n dot lm | >= .4, then the projection of the y-axis on the surface of the element is taken as the reference axis. The left hand side of the inequality should be squared. ( n dot lm)**2 >= .4.

Known Error

CR 32143

Product

MSC / MD Nastran

Corrected Version GL Abstract

P-Elements - TETRA - Incorrect Mass Matrix The mass for TETRA p-elements at p-level 1 is incorrectly calculated.

Description

Avoidance: Run the analysis at a p-level of 2 or higher when using TETRA p-elements are present.

Known Error

CR 32145

Product

MSC / MD Nastran

Corrected Version 70.5.2 Abstract

Transient Analysis - TRD1 - Received Signal 10 Transient analysis may fail in the TRD1 module with no message. The log file may contain a machine dependent message of the form:

Description *** Received signal 10 (SIGBUS) time: command terminated abnormally

Known Error

CR 32145 Avoidance: The error is machine dependent and is caused by a boundary alignment problem. The error will only occur on HP, SUN and SGI systems (Digital will print warning messages but will complete successfully). The error should be avoided by increasing memory by exactly 2 words on HP and SUN system and by 6 words on SGI systems.

Known Error

CR 32157

Product

MSC / MD Nastran

Corrected Version GL Abstract

Online Documentation - Installation - Not a Valid WorldView Document The MSC/NASTRAN Online Encyclopedia issues a "Not a valid WorldView document:" error message when any hotlink button on a book selected from the main books menu is picked. Iview configuration file entries for fulltextPath and welcomeDoc are valid and the documents could be selected manually from the Open/File menu picks.

Description

Resolution/Avoidance: This problem could occur on any system where: 1) the mne collections are moved from one location to another 2) the mne installation directory is nfs mounted or linked to a differently named location As part of the installation process, several *.cfg files are created on the fly and locations are hardcoded with pathname of the installation directory. If the mne collection directory is changed, it is not sufficient to upd

Known Error

CR 32168

Product

MSC / MD Nastran

Corrected Version 70.5.2 Abstract

Description

Matrix Methods - DCMP - SFM 4276 EC 7777 It is possible that a job that should fail in DCMP with a max ratio error, identifying the problem degrees of freedom, instead fails with a traceback in sparse decomposition. The following is an example of the traceback from an hpux system.

Known Error

CR 32168 Process traceback ... ( 0) 0x0009700c sysrcv + 0x320 [/cae_k_apps/msc/msc70/hpux/analysis.pa2_0] ( 1) 0x00f83310 _sigreturn [/cae_k_apps/msc/msc70/hpux/analysis.pa2_0] ( 2) 0x005efba0 dfmsj_ + 0x130 [/cae_k_apps/msc/msc70/hpux/analysis.pa2_0] ( 3) 0x0022b7b4 dfmsa_ + 0x2b20 [/cae_k_apps/msc/msc70/hpux/analysis.pa2_0] ( 4) 0x004c355c sdcomp_ + 0xb8 [/cae_k_apps/msc/msc70/hpux/analysis.pa2_0] ( 5) 0x00220eb8 dcmpa_ + 0x2b8 [/cae_k_apps/msc/msc70/hpux/analysis.pa2_0] ( 6) 0x000c0fe8 dcmp_ + 0x130 [/cae_k_apps/msc/msc

Known Error

CR 32171

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Composites - PARAM,POST,0 - Missing output Laminar stress and strain output is not written to the xdb file in SOL 103 and 105. Avoidance: Insert the following DMAP alter:

Description

compile sedrcvr alter 'DBC OSTR1' endIF $ SORT2 alter 'endIF $ SORT2'(3),'' endalter

Known Error

CR 32174

Product

MSC / MD Nastran

Corrected Version 70.5.1 Abstract

Installation - xnastran not delivered

Description

The XNASTRAN utility is missing from the Version 70.5 (R1) CD. The executable file, /msc705//Xnastran, can be copied from any earlier version.

Known Error

CR 32176

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - EIGR - Point Normalization

Description

In modal analysis (sol 103), when POINT normalization is selected on the

Known Error

CR 32176 EIGR bulk data entry, and the defined component is zero, NASTRAN does not revert to MAX as specified in the Quick Reference guide for the EIGR bulk data entry: NORM Method for normalizing eigenvectors. (Character: "MASS," "MAX," or "POINT"; Default+"MASS") . . POINT Normalize to a positive or negative unit value of the component defined in fields 3 and 4 (defaults to "MAX" if defined component is zero). Documentation of NORM POINT should read: . . POINT Normalize to a positive or negative unit value of the component defined in fields 3 and 4 (defaults to "MASS" if defined component is zero).

Known Error

CR 32177

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - QRG, INIT FMS - Incorrect Default values

Description

Under the description of the INIT command in the Quick Reference Guide, the default values for DBALL and SCR300 are stated incorrectly as 25000 and 175000 blocks. The correct default value is 250000 blocks for each of the DBSETs.

Known Error

CR 32193

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Nonlinear Analysis - CELAS1, CELAS3, PELAST, NLITER - SFM 2085 If the CELAS1 or CELAS3 element references the PELAST entry in a nonlinear analysis where the TKNID field is used to define the nonlinear force vs. displacement relationship, the job will fail with the following message:

Description

*** SYSTEM FATAL MESSAGE 2085 (NLITER) ELEMENT TYPE 11 NOT SUPPORTED FOR NONLINEAR ANALYSIS. *** SYSTEM FATAL MESSAGE 3007 (NLITER) ILLEGAL INPUT TO SUBROUTINE NLEMG Avoidance: Use the CBUSH entry and define the nonlinear force vs.

Known Error

CR 32193 displacement relationship through the KN field on the PBUSHT entry.

Known Error

CR 32218

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Optimization/Design Sensitivity - CBUSH, DVGRID - SFM 3007 In shape optimization, if the CBUSH element is present, (even when not referenced by a DVGRID), the job fails with the following fatal message, "element type 102 is not supported *** SYSTEM FATAL MESSAGE 3007 (DOPR6) ILLEGAL INPUT TO SUBROUTINE Dopr6a". Avoidance: Don't use the CBUSH element in a shape optimization run.

Known Error

CR 32220

Product

MSC / MD Nastran

Corrected Version 2001.0.1 Abstract

Transient Analysis - TSTEP - UFM 4562 In a modal transient analysis, the following error messages may be erroneously issued after the completion of the job.

Description

0*** USER FATAL MESSAGE 4562, TSTEP (TIME STEP) DATA IS MISSING Avoidance: This message can be safely ignored if all the requested output is obtained.

Known Error

CR 32225

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - QRG, System Cell 206 - Missing Option

Description

Option 9 of system cell 206 which selects the better of METIS and MMD, is not documented in the Version 70.5 Quick Reference Guide.

Known Error

CR 32259

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Aeroelastic Analysis - Incorrect Answers for Unrestrained Hinge Moment Coeff.

Known Error

CR 32259 Two errors have been detected that relate to the printing of unrestrained hinge moment coefficients in SOL 144 (static aeroelasticity): 1. The unrestrained hinge moment coefficient values printed for the "INTERCEPT" coefficients are in error if they are nonzero.

Description

2. If there are multiple subcases with the same Mach and q (dynamic pressure) conditions, the unrestrained hinge moment coefficient values printed for the second and subsequent subcases are in error. The coefficients for the first subcase are deemed correct with the exception of the INTERCEPT value mentioned previously. Avoidance: Make the following DMAP change: compile aestatrs list alter 'totu','kbrzx' dbstatus ipzf//s,n,noipz $ if ( noipz=-1 ) matgen ,/ipzf/7/norset/1 $ add ipzf,/mipzf/-1.0 append mipzf,k

Known Error

CR 32264

Product

MSC / MD Nastran

Corrected Version 69 Abstract Description

Parallel Processing - EMA - Wrong Answers Due to an error in parallel EMA, any system running parallel EMA (even if they are only using one processor), could get wrong answers. Avoidance: Use the serial version.

Known Error

CR 32282

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Description

Utilities - XNASTRAN - xmonast Started with the Wrong File Names The XNASTRAN utility does not properly handle an alternate input data file type, e.g., "example.bdf", when directly starting XMONAST to monitor a job. It will attempt to directly start XMONAST on the files "example.bdf.f04", "example.bdf.f06", and "example.bdf.log". Instead, it should be setting the nastran command's "xmon" keyword and relying upon the nastran command to correctly monitor the job.

Known Error

CR 32282 Avoidance: Set "xmon=yes" in an RC file or as an "advanced argument" and do not use XNASTRAN's ability to start XMONAST.

Known Error

CR 32286

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Superelement - STATSUB, multiple subcases - SFM 6710 (TAFF) When more than one static subcase exists in the bulk data for forming the differential stiffness matrix for a normal modes analysis (STATSUB), and the model contains superelements, then the job will fail with the following unclear messages: *** USER INFORMATION MESSAGE 7325 (SEP2DR) PROCESSING OF SUPERELEMENT 10 IS NOW INITIATED. ^^^ USER INFORMATION MESSAGE 9049 (SEKDR) ^^^ SUPERELEMENT DIFFERENTIAL STIFFNESS GENERATION, ASSEMBLY, AND REDUCTION.

Description *** SYSTEM FATAL MESSAGE 6710 (TAFF) THE THIRD INPUT PARAMETER TO MODULE TAFF REFERENCES AN UNDEFINED LOAD SET ID. 0FATAL ERROR This job will fail even if there is only one static subcase callout, but there are multiple loadings in the bulk data section that are not used. Avoidance: There are two possible Known Error

CR 32294

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract Description

Miscellaneous - ISHELL - Insufficient Memory on CRAY Use of the ISHELL utility on a CRAY computer may cause the job to fail due to insufficient memory. Avoidance: Specify twice the memory that the job would normally take.

Known Error

CR 32296

Product

MSC / MD Nastran

Corrected Version 2005.1 Abstract

Differential Stiffness - STATSUB, Superelements - UFM 5423 (MPYAD)

Description

In SOL 105, or if differential stiffness is requested (STATSUB Command)

Known Error

CR 32296 in SOLs 103 and 107 through 112, when superelements are present and no SUPER command, or SUPER=ALL, is specified, then static loads will be generated for the second or dynamic subcase and the job will fail with the following error messages. *** USER FATAL MESSAGE 5423 (MPYAD) ATTEMPT TO MULTIPLY INCOMPATIBLE MATRICES COLS ROWS FORM TYPE NZWD DENS TRAILER FOR GOAT IS 106 12 50 2 2 60 4333 TRAILER FOR UAS IS 103 1 12 2 2 8 3333 TRAILER FOR UOOX IS 104 2 50 2 2 40 2000

Known Error

CR 32303

Product

MSC / MD Nastran

Corrected Version GL Abstract

Nonlinear Transient Heat Transfer - SUBCASE, SET - Missing Output In nonlinear transient heat transfer (SOL 159), if different subcases request different outputs, only the request for the first subcase will be honored and no output will be obtained for subsequent subcases. In the following example thermal results for grid 1 and 2 will be output for subcase 1 but no thermal output will be obtained for subcase 2.

Description

SUBCASE 1 TSTEPNL = 100 DLOAD = 200 SET 1 = 1,2 THERMAL =1 SUBCASE 2 TSTEPNL = 100 DLOAD = 200 THERMAL = ALL

Avoidance: The only avoidance is to request the same output for all subcases above the first subcase. In the above example, request THERMAL=ALL above the first subcase. Known Error

CR 32320

Product

MSC / MD Nastran

Known Error

CR 32320

Corrected Version 70.7 Abstract

Inertia Relief - PARAM,ALTRED,YES - Wrong Answers If PARAM,INREL,-1 and PARAM,ALTRED,YES are specified then wrong answers are produced. Avoidance: Insert the following DMAP alter:

Description

compile phase0 alter 'LFIXEDB OR INREL\=-1','' IF ( LFIXEDB ) ALTRED='NO' $ alter 'SEID\=0 and (LFIXEDB','' IF ( SEID=0 and (LFIXEDB or cditer>0) ) INREL0=false $ compile sedisp alter 'MPYAD LAO,UA,UOX','IF ( FIXEDB\>-1 ) CALL SEGOA,' if ( inrel0 ) then $ IF ( SEID=0 ) THEN $ IF ( inrel=-1 ) then $ MPYAD UOx,CRX,/UOXx $ else $ equivx uox/uoxx/-1 $ endif $ else $ MPYAD UOx,CRj0,/UOXx $ endif $ else $ equivx uox/uoxx/-1 $ endif $ MPYAD LAO,UA,UOXx/UOY/1 $

Known Error

CR 32321

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Static Analysis - PARAM,ALTRED,YES and MPCFORCE - Missing output MPCForce output is not computed if PARAM,ALTRED,YES is specified. Avoidance: Insert the following alter:

Description

compile sedisp alter 'sdr1'(3,1) ENDIF $ ALTRED alter 'ENDIF \$ ALTRED','' endalter

Known Error

CR 32362

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation, Interface Elements - GMBDC, GMBNDS - DMAP Fatal Message 9050 The Quick Reference Guide bulk data definitions for the GMBNDC and GMBNDS entries needs the following remark added:

Description

The interface elements may generate high or negative matrix/factor diagonal ratios. If there are no other modelling errors, these messages may be ignored and PARAM,BAILOUT,-1 may be used to continue the run.

Known Error

CR 32364

Product

MSC / MD Nastran

Corrected Version 70.5.2 Abstract

Postprocessing - TABPRT, OUTPUT2 - Wrong Answers, SWM 1204 Incorrect data may be output by a TABPRT and/or an OUTPUT2 request using the neutral option. Many occurences of SYSTEM WARNING MESSAGE 1204 may be an indication of a problem.

Description

Avoidance: For the OUTPUT2 neutral option, increase mem such that the value is at least f2 x size of largest record + 2 x nasbuff + compiled length of the NDDL of that datablock For TABPRT NDDL-output, increase mem such that the value is at least 4 x size of largest record + 1 x nasbuff + compiled length of the NDDL of that datablock

Known Error

CR 32365

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation/QRG - SESUP - Problems with free-free Dynamic Reduction

Description

Models with free-free component modal superelement reduction give poor answers (or may fail). This limitation should be documented under the SESUP entry by adding the following remark:

Known Error

CR 32365 5. SESUP bulk data records are not allowed for Part (partitioned bulk data) Superelements. Use the SUPORT bulk data records to identify component rigid body modes.

Known Error

CR 32375

Product

MSC / MD Nastran

Corrected Version 70.5.2 Abstract Description

P-Elements - Transverse Shear Strain Output Mis-Labeled The p-shell element's two transverse shear strain outputs for the default curvature option are switched. Otherwise the values are correct. Avoidance: There is no avoidance.

Known Error

CR 32376

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation/P-Elements - OUTRCV - Missing P-Shell Output

Description

When the PROJ=F option is used on the OUTRCV bulk data entry for p-shell elements, no output is produced in the .f06 file. The option should be used if a postprocessor requires results in terms of 3D vectors or tensors, for example, stress tensors with 6 stress components. The option does not produce output in the print file *.f06.

Known Error

CR 32388

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Nonlinear Transient Analysis - TSTEPNL, ADD5 - UFM 4276 GETSTR ERROR CODE 31 If a nonlinear transient analysis has trouble converging and output is not requested for every timestep, the job mail fail with one of the following type messages in ADD5.

Description

0*** SYSTEM FATAL ERROR 4276.NXTCOL ERROR CODE -31 PID= 0 -> CELAS2 0*** SYSTEM FATAL ERROR 4276.GETSTR ERROR CODE 31 PID= 0 -> CBUSH1D Avoidance: Request output for every timestep.

Known Error

CR 32390

Product

MSC / MD Nastran

Known Error

CR 32390

Corrected Version 70.7 Abstract

Cyclic Symmetry - READ, REIGL - UIM 6137, SFM 3001 The READ module may issue the message: UIM 6137 INPUT MATRIX TO DECOMPOSITION HAS xx SINGULARITIES, followed by *** SYSTEM FATAL MESSAGE 3001 (READ). This is due to null columns in the matrices. For cyclic symmetry AUTOSPC does not remove unused degrees of freedom if they are for grid points listed on CYJOIN records.

Description

Avoidance: For solid element models, add a bulk data record GRDSET,,,,,,456 to remove unused rotation degrees of freedom. Setting NASTRAN SYSTEM(273)=1 (Use earlier version Lanczos method) has been shown to work as well in NAST705. The following ALTER may be applied to version 70.5: COMPILE MODERS ALTER 'MATMOD *CASES' SETVAL //S,N,METHTYP/0 $ MESSAGE //'DO A-SET REDUCTION FOR MASSLESS DEGREES OF FREEDOM'

Known Error

CR 32394

Product

MSC / MD Nastran

Corrected Version 70.5.1 Abstract

Complex Eigenvalue Analysis - EIGC - SFM 3008 (UTMCOR) The new block complex lanczos method in Version 70.5 (selected by setting system(108)=4) does not accurately predict the memory requirement. For large problems this may lead to the following fatal message:

Description

*** SYSTEM FATAL MESSAGE 3008 (UTMCOR) MODULE = CEAD INSUFFICIENT CORE AVAILABLE FOR SUBROUTINE CLDRV USER ACTION: INCREASE OPEN CORE BY AT LEAST 1130847 WORDS PROGRAMMER INFORMATION: LOCATION KEY = TSLSPILL Avoidance: The fatal message may not be able to be avoided by increasing memory. The analysis may have to be performed with another method.

Known Error

CR 32395

Product

MSC / MD Nastran

Corrected Version 70.5.2 Abstract

Eigenvalue Analsysis - EIGRL, READ - SFM 7340 (LNNHERR)

Description

The new lanczos in MSC/NASTRAN Version 70.5 may fail with some variation

Known Error

CR 32395 of the following message: *** SYSTEM FATAL MESSAGE 7340 (LNNHERR) process error reported by subroutine LNNDRVS see LNNDRVS abstract (ier = -1)

The message that should have been output is: FACTORIZATION ERROR DURING FINITE INTERVAL ANALYSIS AT FLEFT. FLEFT = -3.9478D-05 *** SYSTEM FATAL MESSAGE 5299 (LNCS1D) FACTORIZATION ERROR AT A BOUNDARY SHIFT. POTENTIAL FIXES: IF LOWER BOUND IS ZERO USE A SMALL NEGATIVE VALUE. IF LOWER BOUND IS A SMALL NEGATIVE VALUE DECREASE IT. ELIMINATE MASSLESS MECHANISMS THE MODEL MAY CONTAIN. Avoidance: Follow the direction of SFM 5299 above. Known Error

CR 32411

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Aeroelastic Analysis - APD, RESTART LOGICAL - UFM 1245 If a read-only restart (RESTART LOGICAL FMS statement) is performed in SOLs 144, 145, or 146, then the run will fail in the APD module with the following message:

Description

0*** USER FATAL MESSAGE 1245, (BIO) AN ALLOCATION ERROR HAS OCCURRED FOR A DATABASE FILE, FILX = 10. WRITE ATTEMPTED ON FILX WHICH WAS OPENED FOR READONLY. Avoidance: Use RESTART with the COPY option.

Known Error

CR 32426

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

P-Elements - GP0 - Distorted Element Edges May Lead to Traceback If a p-element edge is too distorted, the program may fail with the traceback that follows in GP0 instead of exiting with a meaningful message.

Description SIGTRAP - Trace trap FP division by zero

Known Error

CR 32426 Traceback: Offset 0x00001380 in procedure evlpnd_ Offset 0x00000c54 in procedure gp0dc_ Offset 0x00001710 in procedure gp0da_ Offset 0x00000cd4 in procedure gp0_ Offset 0x000004b0 in procedure xsem02_ Offset 0x000009dc in procedure mainal --- End of call chain --Avoidance: Other than correcting the distorted geometry, there is no avoidance.

Known Error

CR 32438

Product

MSC / MD Nastran

Corrected Version 70.5.2 Abstract

Submittal - Wrong executable may be selected on HP-UX 11 Apparently HP will make both 32- and 64-bit versions of HP-UX 11.0 available. As a result of this, if the client is running the 32-bit version of HP-UX 11.0 on a PA-RISC 2.0 system, the nastran command will incorrectly choose the V-class executable. This error can only occur with MSC/NASTRAN V70 and MSC/NASTRAN V70.5 (r1). The bit size of the OS is determined with the following command: $ getconf KERNEL_BITS

Description

The command will print 64 on a 64-bit kernel, e.g., on a V-Class system; and 32 on a 32-bit kernel. Avoidance: Set the following keyword in the either system (e.g., /conf/nast705rc) or node (e.g., /conf/net//nast705rc) RC files. On a PA-RISC 1.1 system: proc= On a PA-RISC 2.0 system: proc=pa2_0 The processor type can be det

Known Error

CR 32457

Product

MSC / MD Nastran

Corrected Version 70.5.2 Abstract

Description

P-Elements - Beam Error Estimator - Poor Answers, Inefficient Processing The error estimators for the beam p-element are incorrect by a factor based on the length of the beam. This error may lead to over adapting or under adapting. That is the error may lead to poor answers or it may lead to an unnecessarily high p-level. Avoidance: There is no avoidance.

Known Error

CR 32458

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Description

ESTIMATE - P-Elements - Insufficient Memory MSC Estimate underestimates memory for input files with P-elements. This limitation will be removed with version 71 for P-element runs without interface elements (GMINTC/GMINTS). The limitation still exists for runs with interface elements. Avoidance: Do not use estimate to determine memory and disk requirements of runs with p-elements prior to Version 71, and do not use estimate to determine memory and disk requirements of any run with interface elements.

Known Error

CR 32467

Product

MSC / MD Nastran

Corrected Version 70.5.5 Abstract

Parallel Processing - Incorrect CPU Times

Description

When parallel processing is selected, the f04 per processor cpu times may show negative cpu times on Version 70.5 NT systems. This problem has been corrected in the Version 70.5.5 release.

Known Error

CR 32476

Product

MSC / MD Nastran

Corrected Version Abstract

Utilities - RCOUT2, BGPDT - rcout2 utility does not transfer data correctly

Description

The rcout2 utility will not transfer the BGPDT correctly on short-word UNIX systems.

Known Error

CR 32477

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Description

Estimate - SPC/SESET THRU 9999999 - performance If an input file has an SPC entry specifying 1 THRU 9999999, then estimate will take a lot of CPU time. This performance error will be removed in version 71. Avoidance: Specify the last grid id instead of 9999999.

Known Error

CR 32482

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

DMAP - DRMS1 - SFE 4276 EC 1305 in ENDPUT. The DRMS1 module may fail with SFE 4276 EC 1305 in ENDPUT.

Description

Avoidance: Reduce the number of subcases (or modes) in the input data blocks to the DRMS1 module.

Known Error

CR 32489

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Aeroelastic Analysis - AEROF - Incorrect Aerodynamic Box ID's

Description

In SOL 146 for Harmonic Gust (Frequency Response), the AEROF= option is supported. However, if the ALL option is used in Version 70.5, the f06 output listing incorrectly lists the Aerodynamic Box ID's as 0 (zero) for all boxes. Whereas, if a specific SET is used, the correct results are obtained. The complex forces printed in both cases, are correct.

Known Error

CR 32490

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Inertia Relief - UPARTN, PARAM,INREL,-1 - Poor Message, UFM 3007 If PARAM,INREL,-1 is specified without any SUPORTi entries then the run will fail in the UPARTN module with the message:

Description

*** SYSTEM FATAL MESSAGE 3007 (UPARTN) ILLEGAL INPUT TO SUBROUTINE PARTN Avoidance: Remove PARAM,INREL,-1 or specify SUPORTi entries.

Known Error

CR 32495

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Nonlinear Statics - PARAM,NMLOOP,-1 and POST,0 - Missing .xdb Output If PARAM,NMLOOP,-1 and PARAM,POST,0 are specified along with multiple subcases in SOL 106, then only the eigensolution results for the last subcase are written to the .xdb file. Avoidance: Insert the following DMAP alter:

Description

compile nlstatic alter 'call super3'(2),'' CALL SUPER3 CASECC ,casei ,PHA ,OLB , , , ,olb , , , ,,,,, ,PCDB ,XYCDB ,POSTCDB ,FORCE , EMAP ,MAPS ,EQEXINS ,PVTS ,CASES , SLT ,ETT ,GOT ,GOQ , , , , , ,GPLS , USET ,SILS

Known Error

CR 32496

Product

MSC / MD Nastran

Corrected Version Abstract

Description

Documentation - PSDF, ATOC, RALL - Random Requests not yet Supported in PATRAN The documentation for the new random analysis data recovery request options PSDF, ATOC and RALL for DISP, VELO, ACC, FORCE, and STRESS documented in the Version 70.5 Quick Reference Guide is misleading. These options are not yet supported in PATRAN and thus are of no use and should not be selected. Presently if they are selected, the random output is written to output2 file and no random output is written to the f06 file. Currently, nothing is written to the xdb graphics data base as might be implied by the Quick Reference Guide remarks. Furthermore, if PARAM,POST,-1, is set, and the OUTPUT2 file is FORMATTED and the new format of the output requests for RANDOM results is used, such as DISP (PSDF) = all then the run will issue UWM 1206 indicating that the datablocks created by the RANDOM module are not written to the OUTPUT2 file.

Known Error

CR 32496 Avoidance: Currently the avoidance is simply do not use these output requests since they are not supported in PATRAN.

Known Error

CR 32504

Product

MSC / MD Nastran

Corrected Version GL Abstract

Restarts - TEMPD - Inefficient Processing If a bulk data entry used to define a temperature loadings (TEMP,TEMPD,etc) is changed on a restart, the restart logic will delete the stiffness matrix and create a new one. This results in inefficient restarts. Avoidance: Either:

Description

1) Place all TEMPi entries in the initial input file, or 2) Insert the following DMAP in the restart run; $ DMAP alter to remove checking for changed in temperature $ BE CAREFUL WHEN USING THIS, AS IT REMOVES SOME OF THE RESTART LOGIC compile ifpl alter 'restart.*geom3,geom3r','' compile phase0 alter 'restart.*geom3s,geom3sr',''

Known Error

CR 32514

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - LOADSET - Only One LOADSET Command is Allowed per Superelement

Description

The Quick Reference Guide description of the LOADSET command does not explicitly state that only one LOADSET command may be used for each superelement (or, in the case of no superelements, only one per run). This command should occur in the first SUBCASE for each superelement (or above the SUBCASEs). Any LOADSET commands in subsequent SUBCASEs will be ignored.

Known Error

CR 32522

Product

MSC / MD Nastran

Corrected Version 70.5.2 Abstract

External Superelements - CSUPER, SPOINTS - Wrong Answers

Description

If an external superelement is brought in using the CSUPER entry and

Known Error

CR 32522 SPOINTs are used for some of the attached dof, it is possible that the matrices will be attached incorrectly. In the problem demonstrating this, if all GRID points were listed before the SPOINTs on the CSUPER, the matrices were attached correctly. If the SPOINTs were listed, then the GRID points, then the matrices were incorrectly attached. (NOTE - the matrices are attached in the order listed on the CSUPER and care must be exercised to verify that the correct order is listed - do not simply change the order on the CSUPER to correct this problem) Avoidance: If possible, use only GRID points on the CSUPER, or be careful to create the matrices for the external superelement in such a way that the terms for the GRID point

Known Error

CR 32526

Product

MSC / MD Nastran

Corrected Version 70.5.2 Abstract

Matrix Methods - MPYAD - SFM 4276, EC 3012 or Wrong Results On the SUN computer, if a MYPAD operation uses the DOT3RD kernel, then the answers may be incorrect or the job may terminate with one of the following error messages: BIOMSG: ERROR 3012 HAS OCCURRED IN ROUTINE QOPEN , FILE INDEX (FILEX) =

Description

process error reported by subroutine LNNP2CD see LNNP2CD abstract (ier = -728) *** SYSTEM FATAL MESSAGE 7340 (LNNHERR) Avoidance: We have been unable to describe in modeling terms when the erroneous method is chosen. To date the error has only been observed in two similar models using superelements while calculating the system modes at the residual. To prevent the incorrect method from ever being selected it is recommended to add the following system cell to the top of the input file or to the system rc file for all runs on V

Known Error

CR 32550

Product

MSC / MD Nastran

Known Error

CR 32550

Corrected Version 2010.1.0 (MD R4) Abstract

Static Analysis - SDR2, GPFDR - Missing Output, SFM 3002, UWM 5244 If a model contains many subcases with mulitple boundary conditions and the boundary conditions are not "grouped" then UWM 5244 in GPFDR or SFM 3002 in SDR2 may result. If the warning message is encountered wrong answers or missing output may result. USER WARNING MESSAGE 5244 (GPFRBI) HAS IGNORED DATA FROM THE PG MATRIX DUE TO INCOMPATIBILITY WITH THE UGV MATRIX OR

Description

*** SYSTEM FATAL MESSAGE 3002 (SDR2) EOF ENCOUNTERED WHILE READING DATA BLOCK UG2 (FILE 112) IN SUBROUTINE SDR2 Avoidance: Group all subcases with the same boundary condition together or insert the following DMAP alter: compile phase1dr alter 'S,N,load'(2) PARAML CASEq//'DTI'/nskip/1//S,N,subid $ load=100000+subid $ compile sestatic alter 'PARAML CASESX'(2) PARAML CASEsx//'DTI'/nskip/1//S,N,subid $ load=100000+subid $ compile sedisp alter 'PARAML USET'(,-1) PARAML CASEw//'DTI'/nskip/1//S,N,subid $ load=100000+subid $ endalter

Known Error

CR 32551

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Optimization/Design Sensitivity - DESVAR, IFP - SFM 4276, Error Code 7777

Description

If integer values are used for XINIT, XLB, or XUP on DESVAR entries, MSC/NASTRAN may fail in the IFP module with either SIGNAL 8, error 7777, or SFE 4276, EC 7777.

Known Error

CR 32551 Avoidance: Correct the format on the DESVAR entries.

Known Error

CR 32557

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Differential Stiffness - STATSUB, Superelements - UFM 4562 in TRLG When performing transient analysis (SOL 109) with superelements and differential stiffness, with STATSUB, then UFM 4562 may be issued.

Description

Avoidance: Insert the following DMAP alter: compile super3 alter 'equivx CASERS' else if ( nocasrs1>-1 ) then $ equivx CASERS1/CASE0/-1 $ for non-SOL 200 with dynamic looping endalter

Known Error

CR 32561

Product

MSC / MD Nastran

Corrected Version 70.5.2 Abstract

Frequency Response/Random Response - RANDPS - Time Command Terminated Abnormally An underflow error may occur on some machines when the random module squares stress values that are numeric zeroes. If this error is encountered the job will stop in the RANDOM module, the f06 file will not contain a message, and the log file may contain and overflow/underflow message. The DEC ALPHA OSF/1 system issued the message:

Description Time command terminated abnormally. Avoidance: Do not request random xy output for very small output quantities. If the quantity is near 1.e-19, when it is squared for random, it can cause an underflow to occur. Most machines will catch this and output a zero in the results. The ALpha stops with no meaningful messages Known Error

CR 32572

Product

MSC / MD Nastran

Known Error

CR 32572

Corrected Version 70.6 Abstract

Description

Superelements - SUBCASE,SUPER - UFM 5423 in SDR1 or UFM 7324, missing output If there exists more subcases for a superelement than the residual structure, then the run may fail with UFM 5423. If the load sequence number is specified on the SUPER commands for the superelement subcases, then UFM 7324 is issued. However, the run continues and output is missing for the extra superelement subcases. Avoidance: Remove the extra superelement subcases or add residual structure subcases.

Known Error

CR 32608

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Inertia relief - DMIG, UACCEL - UFM 6143 If less than 6 degree of freedom are specified on a single grid point on the DMIG,UACCEL entry, then the job will fail with the following messages: *** USER FATAL MESSAGE 6143, (MERGE1) INPUT MATRICES AND VECTORS ARE INCOMPATIBLE Avoidance: Insert the following dmap alter:

Description

$ $ for v70, v70.5 $ compile statrs alter 'UPARTN USET,UACCEL','' IF ( NOUACCEL>=0 ) UPARTN USET,UACCEL/URAx,,,/'G'/'R'/'S'/1 $ alter 'dbstatus','' dbstatus urax//s,n,noura $ alter 'solve ' endif $ alter 'endif \$ nullqrr','' endalter

Known Error

CR 32609

Product

MSC / MD Nastran

Known Error

CR 32609

Corrected Version 2001 Abstract

Documentation - PARAM,UNSYMF - Missing Documentation

Description

Complex eigenvalue analysis may be performed in nonlinear static analysis, SOL 106, with PARAM,UNSYMF,YES. This feature is documented in the Version 70.5 Release Guide but the PARAM,UNSYMF is not documented in the Version 70.5 Quick Reference Guide. The parameter should be documented and referred to from the cmethod case control command in the QRG.

Known Error

CR 32611

Product

MSC / MD Nastran

Corrected Version 70.5.2 Abstract

Description

P-Elements - Beam Error Estimator If there are beam p-elements in a model with no strain, such as rigid body modes in modal analysis, the error estimator may crash. The EPSTOL parameter does not work with beam p-elements so it will not help avoid this error. Avoidance: Exclude beam p-elements from the error estimate in such models, or turn off the error estimator.

Known Error

CR 32612

Product

MSC / MD Nastran

Corrected Version GL Abstract

P-Elements - BEAMP - Wrong Answers at P=2 A BEAMP p-element has bad residual bending flexibility when p=2. The error is more apparent when small values for the modulus "E" are used.

Description Avoidance: Set NASTRAN SYSTEM(226)=1, to turn off the residual bending flexibility. Known Error

CR 32615

Product

MSC / MD Nastran

Corrected Version GL Abstract

Submittal - A "$" Sign in Command Line Argument Causes Argument to be Truncated

Description

If a command line argument contains a dollar sign ('$'), the command line argument is truncated at the dollar sign. This probably should only occur for NASTRAN cards encountered in RC file processing.

Known Error

CR 32615 Avoidance: There is no avoidance for Windows NT. The error can be avoided on UNIX by quoting the argument and escaping the dollar sign, however, a dollar sign is a very unusual UNIX filename character.

Known Error

CR 32626

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Matrix Methods - DECOMP - UFM 9050 (SEKRRS) Excessive Pivot Ratio If negative terms occur on the factor diagonal matrix during matrix decomposition using the SPARSE (default) solver, UFM 9050 will correctly be printed, but the dof containing negative factors on the factor diagonal matrix will not be identified. Terms which have factor diagonal ratios greater than the value of PARAM,MAXRATIO will be properly identified. Avoidance: If the problem is run using NASTRAN SPARSE=1, the degrees of freedom with negative terms in the factor diagonal matrix will be properly identified in the listing.

Known Error

CR 32633

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

ACCESS - smplr - Program to Read .xdb Does not work Properly. A dynamic factor was added for the access key in MSC/NASTRAN Version 70.5. Thus, the program smplr.f delivered with MSC/NASTRAN Version 70.5 does not work properly.

Avoidance: An illustration of the protocode required is:

Description

Call READR (file,ia,0,iret) -1 ) then $ partn ppf,,vppf/ppf1,,,/1 $ partn rpx,,vppf/rpx1,,,/1 $ mpyad rpx1,ppf1,/pdf/1 $ else $ alter 'mpyad ' endif $ endalter

Known Error

CR 33012

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Superelements - SPCs on Boundary Grids - SFM 6804 If a boundary (exterior) point for a PART (BEGIN SUPER = i) superelement is constrained, then the fatal message below will be issued if different displacement coordinate systems are used for the coincident GRID points. SYSTEM FATAL MESSAGE 6804 (BNDSP3) THE DISPLACEMENT COORDINATE SYSTEM (CD FIELD ON GRID ENTRY)

Known Error

CR 33012 SPECIFIED FOR BOUNDARY GRID ID 4 B IN SUPERELEMENT 1 IS NOT CONGRUENT WITH DISPLACEMENT COORDINATE SYSTEMS IN OTHER CONNECTING SUPERELEMENTS. Avoidance: Either apply the constraints in the downstream superelement (the one which has the coincident point as an interior point) or use the same displacement coordinate system on all of the points which are coincident.

Known Error

CR 33016

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation/QRG - SEEXCLD

Description

The Quick Reference Guide description for the SEEXCLD entry states that SEIDA(field 2) must be larger than zero. A value of 0 (zero) is also allowed. Also, the thru range is indicated as 610 and any structural grid points or SPOINTs are assigned interior or exterior to the fluid superelement then SFM 5423 may be issued. Avoidance: Ensure that no structural points appear in the interior and

Known Error

CR 33274 exterior point list for the fluid superelement. This can be verified in the printout of the superelement map. This includes generalized coordinates used for component mode synthesis on the fluid superelement. The seqset1 should be input on fluid points (grid, CD=-1) rather than scalar points.

Known Error

CR 33285

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

Plotting - Aeroelastic Elements - Missing Plot Output Beginning in Version 70.5 the NASTRAN plotter no longer supports aeroelastic elements. Avoidance: The only avoidance is to use Version 70 or PATRAN Version 8.1 which is due out by the end of this year.

Known Error

CR 33299

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

P-Elements - QUAD4 - Poor Answers for p=1

Description

The QUAD4 p-element may be too stiff when p=1 on some edges. This is most noticible for coarse meshes. An avoidance is to specify p >= 2.

Known Error

CR 33307

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Aeroelastic Analysis - AELINK, TRIM - UFM 5267 The above message was produced by a client whose length units was millimeters and mass units were kilograms. The trim matrix became singular in this case, apparently because of the dynamic range within the equations to be solved.

Description

*** USER FATAL MESSAGE 5267 (ASGLD) ZXX MATRIX IS SINGULAR. TRIM AND AELINK ENTRIES SPECIFY AN INADEQUATE CONSTRAINT SET. Avoidance: In this case, the problem was avoided by scaling the ZZX and PZ matrices going into the trim module by 1.0e-4. This avoidance is likely to be problem dependent, so other factors may be required in other cases. The alter to perfrom the scaling is:

Known Error

CR 33307 compile aestatrs alter 'asg'(,-1) add zzx,/zzxs/1.0e-4 $ add pz,/pzs/1.0e-4 delete /zzx,pz,,,/ $ equivx zzxs/zzx/always $ equivx pzs/pz/always $ A more general

Known Error

CR 33309

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

External Superelements - PARAM, EXTOUT, DMIGPCH - UFM 327 When using the external superelement capabilities with the "param,extout,dmigpch" option in a SOL 103 run, the header entry for the load PAX will also be written out, even though it is not used. This will cause the issue of the following error messages in a subsequent attachment run.

Description

*** USER FATAL MESSAGE 327 (IFS2P) BAD DATA OR FORMAT OR NON-UNIQUE NAME. DMIG PAX SORTED CARD COUNT = 161 ^^^ USER FATAL MESSAGE 9002 (IFPS) ^^^ ERROR(S) ENCOUNTERED IN THE MAIN BULK DATA SECTION ^^^ SEE MESSAGES ABOVE. ERROR ENCOUNTERED IN MODULE IFP, Avoidance: Remove the offending PAX header. This entry is not used in a SOL 103 run.

Known Error

CR 33334

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - DEQATN - Increased Limit

Description

The number of allowable non-blank characters for the DEQATN entry was increased from 12,500 to 32,000 in Version 70; however, the Quick Reference was not updated to reflect this.

Known Error

CR 33367

Product

MSC / MD Nastran

Known Error

CR 33367

Corrected Version 70.6 Abstract

Optimization/Design Sensitivity - DESVAR - UFM 316 The message: *** USER FATAL MESSAGE 316 (IFPDRV) ILLEGAL DATA ON BULK DATA ENTRY DESVAR xx SORTED ENTRY COUNT = yy

Description

was produced when a DESVAR punched at the end of an optimization task had an XINIT that was very slightly less than the XLB value. When a new run is attempted, an equality test is used to see if the input satisfies XINIT .ge. XLB and the entry is rejected even though it had been produced in a previous run. Avoidance: Manually reset any punched DESVAR values to satisfy the relations XLB .LE. XINIT .LE. XUB

Known Error

CR 33401

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Case Control - SEALL, SEMG, SEKR, etc. - UFM 9015, Poor Message If the SEALL, SEMG, SEKR, SELG, SELR, or SEMR command is specified in a subcase which is not the first subcase then the operation requested by that command is not performed and various messages or wrong answers may result. For example, with SEALL or SEMG then UFM 9015 will be issued.

Description

USER FATAL MESSAGE 9015 (SEMODES) THE USET TABLE IS NOT PRESENT. Avoidance: Specify SEALL, SEMG, SEKR, SELG, SELR, or SEMR above all SUBCASE commands.

Known Error

CR 33424

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Aeroelastic Analysis - SPLINEi, AESTATRS - UFM, Incompatible Matrix Multiply

Description

An incompatible matrix multiply can occur in calculating the intercept hinge moment coefficients if the aerodynamic forces are splined only to dependent degrees of freedom (e.g., to m-set and r-set points).

Known Error

CR 33424 Avoidance: A DMAP workaround is to include the following alter: compile aestatrs $ alter 'add *uintl','add *intl' $ type parm,,i,n,nointl $ dbstatus uintl//s,n,nointl $ if ( nointl < 1 ) then $ PARAML ALX//'TRAILER'/2/S,N,NOLSET $ MATGEN ,/MUNTL/7/NOLSET/1 $ MATGEN ,/MINTL/7/NOLSET/1 $ else $ ADD UINTL,/MUNTL/-1.0 $ ADD INTL,/MINTL/-1.0 $ endif $ endalter $

Known Error

CR 33427

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Aeroelastic Analysis - AELINK, RESTART, MPYAD - SFM 5423 An error in the dependencies results in restarts into solution 144 where only the AELINK entries have been changed failing with SYSTEM FATAL MESSAGE 5423 indicating an attempt to multiply incompatible matrices:

Description

SYSTEM FATAL MESSAGE 5423 (DMPYAD) ATTEMPT TO MULTIPLY INCOMPATIBLE MATRICES COLS ROWS FORM TYPE NZWD DENS TRAILER FOR WSKJ IS 101 40 80 2 2 4 250 TRAILER FOR FFAJI IS 102 7 40 2 2 80 10000 TRAILER FOR FFINT IS 103 2 80 2 2 0 0

Avoidance: Do not attempt restarts when only changing AELINK bulk data entries. A simultaneous change in the aerodynamic model geometry will enable the restart, but this would also entail recalulation of the aerodynamics. Alter Known Error

CR 33454

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - EIGC, SYSTEM(108) - Block Complex Lanczos is not the Default

Known Error

CR 33454

Description

The more modern and reliable Hessenberg which supports spill was made the default in Version 69 by switching the meaning of system(108)=0 and 1. However, the documentation was never updated to reflect this change. Furthermore, because of poor performance for some problems the new Block Complex Lanczos was not made the default in Version 70.5. Although this decision is reflected in the release notes the decision was made too late to be reflected in the Quick Reference Guide's description of system(108) under the NASTRAN command and EIGC entry.

Known Error

CR 33476

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Miscellaneous - Elapsed Time Incorrect

Description

The elapsed time will be incorrect if more that 24 hours are spent in any one module.

Known Error

CR 33480

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Postprocessing - SOL 1 through 16, PARAM,POST - Missing output No results will be written to the .op2 or .xdb file if PARAM,POST is specified in SOLs 1 through 16 where SORT2 is the default output format or in all SOLs if SORT2 is explicitly requested. Avoidance: Insert the following DMAP alter in any SOL 1 through 16:

Description compile sol__ $ insert SOL number for __ alter 'IF (POST=0) THEN'(,-1) LABEL LNOSORT1 $ alter 'LABEL LNOSORT1','' endalter Known Error

CR 33481

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Estimate - SPC - Undefined GRID referenced

Description

When an SPC references an SPOINT, the estimate utility may indicate that a undefined GRID has been referenced.

Known Error

CR 33491

Product

MSC / MD Nastran

Corrected Version 70.6.1 Abstract

Description

Optimization/Design Sensitivity - CAABSF - UFM 7115 The acoustic absorber element (PAABSF) is not supported in optimization and design sensitivity (SOL 200). If a PAABSF entry is included in the bulk data, even if it is not one of the design variables, the following message is issued, " *** USER FATAL MESSAGE 7115 (DOM2B) PTYPE 1502 15 IS NOT SUPPORTED". Avoidance: Do not include PAABSF entries in an optimization run.

Known Error

CR 33500

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

Static Aeroelastic Analysis - Wrong Answers for Multiple Interference Groups If multiple interference groups are used with bodies in any interference groups except the last one and control surfaces exist, the DJX matrix generated by ADG (adgdjx routine) is corrupted. Avoidance: Specify a single interference group.

Known Error

CR 33527

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Iterative Solver - ITER, JACOBI - SWM 6715 An error in the iterative solver for real-unsymmetric problems using the default Jacobi preconditions may lead to poor convergence and the message below:

Description

*** SYSTEM WARNING MESSAGE 6715 (SUCGRD) THERE IS A ZERO DIAGONAL TERM IN COLUMN 1 OF DATA BLOCK CEE WHICH WILL BE REPLACED BY 1.0 IN THE PRECONDITIONER. USER ACTION: IT MAY BE BETTER TO USE CHOLESKY PRECONDITIONING (PRECOND=C ON ITER BULK DATA ENTRY) OR THE DIRECT SOLVER (ITER=NO ON NASTRAN STATEMENT) FOR THIS PROBLEM.

Known Error

CR 33527 Avoidance: The error is caused because instead of using the diagonal terms of the stiffness matrix as the Jacobi preconditioner (as intended) the iterative solver is running with an identity matrix as the preconditioner which is the same as running with no preconditioner at all. Use

Known Error

CR 33529

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

DBC - CTRIAR, PARAM,POST - UFM 6498 If a run with a ctriar element is execute back to back and the xdb file is not removed, the job will fail with the following message unclear message:

Description

*** USER FATAL MESSAGE 6498 (MsgGetStr) Message number is not found PROGRAMMER INFORMATION: Check call to MSGPOP from with the message number 0.0 Severity is INVALID ERROR TYPE (0) Parameter 1 is 3 Parameter 2 is CTRIAR Parameter 3 is CTRR Parameter 4 is 0 USER ACTION: Please contact MSC Client support *** USER FATAL MESSAGE 6498 (MsgGetStr) Avoidance: Delete the xdb and re-submit the job.

Known Error

CR 33533

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Description

Superelements - Component Modes, SECSET - Possible Wrong Answers If free-free component modes are used (e.g., secset), then the eigenvectors may be incorrect. A symptom of this error is indicated by the discrepancies between the eigenvalues printed in the eigenvalue table versus the eigenvalues printed at the top of the eigenvector output. Avoidance: Do not use free-free components, use the default fixed-fixed component modes. See related error 32365.

Known Error

CR 33543

Product

MSC / MD Nastran

Corrected Version 70.6

Known Error

CR 33543

Abstract

Estimate - Recommends Setting SPARSE=1

Description

The estimate program may incorrectly recommend turning sparse decomposition off (i.e. setting SPARSE=1) for tet models. Sparse decomposition is virtually always better than standard decomposition for decomposing stiffness matrices for real world models. Sparse should never be turned off.

Known Error

CR 33559

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - PSHELL, STRESS(MAXS) - MAXS is not an Equivalent Stress

Description

A remark should be added to the Quick Reference guide description of the STRESS case control command that MAXS for shell elements is not to be confused with an equivalent stress as is the case for von Mises stress or the octahedral stress.

Known Error

CR 33566

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Static Analysis - PARAM,EXTOUT,DMIGPCH - UFM 327 (IFS2P) If param,extout,dmigpch is used in but there are no loads (for example in an eigenvalue analysis) a header record for the "PAX" load matrix is printed to the punch file. When this punch file is included in the bulk data of a subsequent run, the job will fail with the following message:

Description

*** USER FATAL MESSAGE 327 (IFS2P) BAD DATA OR FORMAT OR NON-UNIQUE NAME. DMIG PAX SORTED CARD COUNT = 52 ^^^ USER FATAL MESSAGE 9002 (IFPS) ^^^ ERROR(S) ENCOUNTERED IN THE MAIN BULK DATA SECTION ^^^ SEE MESSAGES ABOVE. ERROR ENCOUNTERED IN MODULE IFP, Avoidance: Edit the punch file and delete the DMIG entry for PAX.

Known Error

CR 33568

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Optimization/Design Sensitivity - DSAD, PARAM,NOCOMP, PCOMP - SFM 3007

Known Error

Description

CR 33568 When param,nocomps,0 is used in an optimization run with composite stress or strain responses the following message will occur and homogeneous responses are also requested, the following SFM is produced: *** SYSTEM FATAL MESSAGE 3007 (DSAD ) ILLEGAL INPUT TO SUBROUTINE DSAD12 Avoidance: Use param,nocomps,1 which is the default.

Known Error

CR 33572

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Installation - MSC_LICENSE_FILE env var supersedes RC file "auth" keyword The precedence of the "authorize" keyword hierarchy in the "MSC/NASTRAN Configuration and Operations Guide", Section 3.2, is incorrect. The actual hierarchy is:

Description

1) "authorize" keyword on command line. 2) MSC_LICENSE_FILE environment variable. 3) "authorize" keyword in an RC or RCF file. 4) /flexlm/licenses/license.dat 5) /conf/authorize.dat /conf/authoriz.dat # Windows NT 6) LM_LICENSE_FILE environment variable. Note, the first three items are consistent with all other nastran command keywords.

Known Error

CR 33573

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Description

Optimization/Design Sensitivity - DOPTPRM - Mislabeled Output The P2 parameter on the DOPTPRM entry is used to control the output of design optimization results. The output that is produced for composite responses is scrambled in that CFAILURE output appears as CSTRESS, the CSTRESS appears as CSTRAIN and the CSTRAIN appears as CFAILURE. Avoidance: The numerical values are correct. It is only the labeling that is in error.

Known Error

CR 33588

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Optimization/Design Sensitivity - DSAD, CSTRESS, CSTRAIN, CFAILURE - SFM 3007 The message: *** SYSTEM FATAL MESSAGE 3007 (DSAD) ILLEGAL INPUT TO SUBROUTINE DSAD13

Description

can be produced if there is a combination of CSTRESS, CSTRAIN, and CFAILURE response types on DRESP1 entries and they invoke different sets of elements.

Avoidance: Either only use one composite response type or apply the multiple response types to exactly the same set of elements. Known Error

CR 33600

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Aeroelastic Analysis - RESTART, MKAERO - Wrong Answers If a restart is selected with additional MKAERO data, only the new MKAERO pairs will be used in the Flutter or Dynamic Aeroelastic analysis and the original data will be ignored. Avoidance: For SOL 145, apply the following dmap alter in the restart run:

Description

compile flutter alter 'cntr'(2,-1) endif $ alter 'endif'(2),'endif'(2) For SOL 146, the appropriate alter is: compile seaero alter 'cntr'(2,-1) endif $ alter 'endif'(7),'endif'(7)

Known Error

CR 33606

Product

MSC / MD Nastran

Known Error

CR 33606

Corrected Version 70.7 Abstract

SSSALTERs - checka.v705 - SFM 3007, Illegal Input to Subroutine CALCV If the sssalter checka.v705 is used on a deck that has no spcs or rigid elements then the message:

Description

SYSTEM FATAL MESSAGE 3007, ILLEGAL INPUT TO SUBROUTINE CALCV may be encountered. Avoidance: Put in a dummy grid point and constraint.

Known Error

CR 33626

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Postprocessing - Nonlinear Analysis, PARAM,POST,0 - SWM 6066 (DBC) In nonlinear analysis with superelements, MSC/NASTRAN Version 70 and 70.5 may fail with messages similar to those below when it attempts to write results to the XDB file. *** SYSTEM WARNING MESSAGE 6065 (DBC) *** DBCMSG ERROR MESSAGE 44 FROM SUBROUTINE DBCAOL OUTPUT LIST DOES NOT MATCH EXISTING IN THE DATABASE, MERGE/RESTART OPERATION IMPOSSIBLE.

Description MSC/XL DATA BASE CONVERSION FINISHED *** SYSTEM WARNING MESSAGE 6066 (DBC) *** DBCMSG ERROR MESSAGE 34 FROM SUBROUTINE DBC THE DBC MODULE HAS BEEN TERMINATED BECAUSE OF THE ABOVE FATAL DBC ERROR. USER INFORMATION: SUBSEQUENT DBC CALLS WILL NOT BE EXECUTED, AND THE DATABASE CONVERSION IS INCOMPLETE. *** DBCMSG ERROR MESSAGE 14 FROM SUBROUTINE DBCROL UNABLE TO OPEN INPUT RELATION NLLF RETURN Known Error

CR 33628

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Superelements - CSUPEXT - UWM 4155

Description

If an image superelement has SPOINTs for component mode synthesis the the following warning message may be incorrectly encountered:

Known Error

CR 33628 USER WARNING MESSAGE 4155---GRID POINTS FOR SECONDARY SUPERELEMENT 82 ARE COLINEAR. CONFORMITY CHECKS NOT MADE.

Known Error

CR 33629

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation/P-Elements - CBEAM, CQUAD4, CTRIA3 - SFM 6352 If beam and plate p-elements are used in random analyses, the following uninformative message is printed in the .f06 file:

Description

*** SYSTEM FATAL MESSAGE 6352 (SDRP36) LOGIC ERROR: KERROR= 7. USER ACTION: CONTACT MSC CLIENT SUPPORT. PROGRAMMER INFORMATION: SUBCASE ID = 101 IN RECORD NUMBER 29 OF OUGV1 DATA BLOCK DOES NOT MATCH THE SUBCASE ID = 102 IN RECORD NUMBER 2 OF CASEDR DATA BLOCK. 0FATAL ERROR Avoidance: There is no avoidance, p-elements are not supported in random analysis.

Known Error

CR 33644

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Transient Heat Transfer - Multiple subcases with DLOAD - Wrong Answers Different DLOADs may not be applied in different subcases of a transient heat transfer analysis. If attempted the load applied in the first subcase will be lost in the second subcase.

Description

Avoidance: Loads should be combined in a single DLOAD. If multiple subcases are necessary to reference different tstepnl entries, than the DLOAD case control request should be put above the subcase level.

Known Error

CR 33725

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Matrix Methods - MPYAD - System Fatal Message

Known Error Description

CR 33725 If insufficient scratch space is available for a large mpyad, the job may crash and a meaningful message may not be output. Avoidance: Increase the amount of scratch space available ot the job.

Known Error

CR 33726

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Optimization/Design Sensitivity - Aeroelastic Analysis, FLUTTER - SFM 7088 The message: *** SYSTEM FATAL MESSAGE 7088 (DOPR3I) MODE NO. xx ASSOCIATED WITH FLUTTER DRESP1 ID = yy EXCEEDS 0, THE NUMBER OF MODES AVAILABLE FROM THE ANALYSIS.

Description

may be produced in error when NVALUE is not explicitly specified on the FLUTTER entry. Since there is a default value for NVALUE, the input may be valid. The message is also incorrect in that it is (a) listed as a system fatal message when it should have been a user fatal message and (b) the run does not stop despite the supposedly fatal message. Avoidance: If the default value has been used for NVALUE, the message can be ignored.

Known Error

CR 33749

Product

MSC / MD Nastran

Corrected Version 2005.5 Abstract

Composites - No ply failure indices with STRAIN case control When STRAIN ply results are requested, failure indices are not calculated. Avoidance:

Description

Supply a STRESS=n also, where n is the set of elements that will have failure indices calculated, but you get the extra ply stress results in addition to the ply strain results..

See related CR 1-18756447 which is being fixed right now. Known Error

CR 33753

Product

MSC / MD Nastran

Known Error

CR 33753

Corrected Version 2001 Abstract

Documentation/QRG - Replication example in QRG results in UFM 6721 The replication example in the Version 70.5 Quick Reference Guide on page 427 results in USER FATAL MESSAGE 6721. The example: GRID, 101, 17, 1.0, 10.5,,17,3456 =(4),*(1),=,*(0.2),==$

Description Should be changed to: GRID, 101, 17, 1.0, 10.5,,17,3456 =,*(1),=,*(0.2),==$ =3 Known Error

CR 33770

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Documentation - Submittal - submit - Poor Message A Bourne shell cannot be used to process the job file in a user's submit command. If a Bourne shell is used, the following error may occur: -sh: MSC_ASG=/Stemp/TT7293_19.asg: is not an identifier The error message: MSC_ASG=/Stemp/TT7293_19.asg: is not an identifier

Description

was written by the Bourne shell, /bin/sh, and was complaining about an export command. Avoidance: Do not specify a Bourne shell. Section 3.11 of the "Configuration and Operations Guide" does specifically state that a Korn shell must be used. However, the example should be changed from "-s /bin/sh" to "-s /bin/ksh". Note, the use of "/bin/sh" is correct on a POSIX-compliant system, but could be misleading to an inexperienced user.

Known Error

CR 33775

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Optimization/Design Sensitivity - MODES - Missing Output

Description

When an optimization job with ANALYSIS=MODES uses more than one MODES statements

Known Error

CR 33775 in Subcase Control section, the results are printed in *.f06 file only for the first subcase. Avoidance: Do not use the MODES command.

Known Error

CR 33776

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Description

Aeroelastic Analysis - AEROF - Null AEROF Output The AEROF output from solution 146 is all zeroes in Version 70.5. For frequency response analysis, the AEROF case control command should produce force and moment data for the the aerodynamic boxes of the DLM. Avoidance: A workaround is to supply a Case Control SET having the desired ids and referencing that SET in the output request: AEROF=

Known Error

CR 33779

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Description

Grid point stress - PSOLID, GPSTRESS, CORDM - Wrong Answers When higher order solid elements are used in Grid Point Stress Volumes, and their PSOLID references a material coordinate system, the local grid point stress will be incorrect. The invariants, such as Pressure or Von Mises are correct. Avoidance: Use the default basic coordinate system.

Known Error

CR 33797

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Aeroelastic Analysis - GUST - Documentation Clarification

Description

The Version 64 Programmer's Manual indicates that the X0 field of the GUST bulk data entry will change the phase relationship (it can be viewed as a time delay) whenever a harmonic gust is used in SOL 146. Also the streamwise location of aerodynamic elements introduces a phase change (a delay) in the aerodynamic forces caused by a harmonic gust. The statement on page 606 paragraph 2 is not completely accurate. The X0 and the aerodynamic element center streamwise location are terms in the equation that calculates the real and imaginary parts downwash for each aerodynamic element. The

Known Error

CR 33797 phase relation represents a time delay for an excitation at X0 to arrive at an aerodynamic box streamwise position.

Known Error

CR 33809

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Aeroelastic Analysis - SPLINEi, SUPORT - Incorrect Unrestrained Hinge Moments The unrestrained hinge moments are in error in static aeroelastic analysis if the aerodynamic and structural model coupling splines the displacements from the suport points to the aerodynamic mesh. This error is caused by omitting the suport point displacements from the computation of the aerodynamic mesh displacements for aeroelastic feedback.

Description

Avoidance: A DMAP avoidance is: compile aestatrs list noref alter 'mpyad *gdkl.*ukpi','' UMERGE USET,ULPI,URPI/UAPI/'A'/'L'/'R' $ mpyad gdka,uapi,/ukpi $ capture the r-set motion, too

Known Error

CR 33818

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Buckling Analysis - large problem - READ, Segmentation Fault On a very large buckling problem, 2.6 million degrees of freedom in this case, depending on the machine, the job may fail with one of the following error messages either in the log or f06 files. The error is caused by trying to solve THE BUCKLING SHIFT SCALE CALCULATION FBS OF a very large problem in core instead of out of core.

Description

Trap encountered: SIGSEGV - Segmentation violation Traceback: Offset 0x0000007c in procedure dbsmr1_ Offset 0x00000488 in procedure gbkmgr_ Offset 0x00000b50 in procedure ionast_ Offset 0x00000040 in procedure girdbk_ Offset 0x000003f8 in procedure sfupfc_

Known Error

CR 33818 Offset 0x0000041c in procedure ssmf1d_ Offset 0x00000598 in procedure ssm5d_ Offset 0x0000039c in procedure bucksd_ Offset 0x000010c4 in procedure lnnrigl_ Offset 0x000

Known Error

CR 33841

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Description

Nonlinear Analysis - Inaccurate Stresses using Drucker-Prager Yield Criterion The Mohr-Coulomb and Drucker-Prager yield criteria (selected on the MATS1 entry) entry create an inaccurate solution. The error is the result of an incorrect correction factor to the yield stress, which accounts for effects of the internal friction angle. Incorrect factors underestimate the yield stresses, resulting in premature yielding in tension. Avoidance: There is no avoidance, but the error is negligible if the strain is very small.

Known Error

CR 33860

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Miscellaneous - Execution Summary - "nan" in the f04 Output If MSC/NASTRAN is run on a computer which has more than 68 CPUs. Then the F04 file may have "nan" in the output.

Description

15:44:41 0:00 0.0 0.0 nan nan SEMTRN BGN Avoidance: There is no avoidance but the "nan" ouput may be safely ignored.

Known Error

CR 33861

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Description

Optimization/Design Sensitivity - DSAJ, DVGRID - abnormally terminated Shape optimization jobs may fail in the DSAJ module on machines that enforce boundary alignment. This includes SUN, HP and Digital Alpha. The log file will contain a message of the form; *** TERMINATING /software/msc/nastran705/msc705/solaris/analysis.ultra

Known Error

CR 33861 *** Received signal 10 (SIGBUS) time: command terminated abnormally. and then a machine dependent traceback: from SUN: t@1 (l@1) signal BUS (invalid address alignment) in unpack_ at 0x8fcc58 unpack_+0x1d8: std %f2, [%o1] (dbx) where =>[1] unpack_(0x275, 0x1, 0x1dbb92c, 0x1a494e0, 0x1a49430, 0x0), at 0x8fcc58 [2] dsaj4_(0x18a88d4, 0x244598, 0x18a8680, 0x18a86d8, 0x1f6d010, 0x18a8638), at 0x244810 [3] dsaj_(0x18a8680, 0x18a8690, 0x1358, 0x18a8574, 0x0, 0x18a8578), at 0x243510 [4] xsem02_(0x123, 0x18852b0, 0x1

Known Error

CR 33863

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Buckling Analysis - PARAM,FOLLOWK, TAFF - Poor Performance If follower force stiffness is turned on (which is the default) in a buckling analysis, and there are many load entries, then the calculation of the follower force stiffness will be extremely slow.

Description Avoidance: If the effect of the follower force stiffness is not important, add the following parameter to the bulk data section: PARAM,FOLLOWK,TAFF

Known Error

CR 33874

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - EIGRL, SYSTEM(146) - Incorrect Description

Description

The descriptions for system cell 146 in the Quick Reference Guide under the EIGRL entry and the NASTRAN statements are incorrect. The system cell values are no longer a percentage increase of the memory reserved for the sparse method, rather, it is calculated as (3 * x * buffsize), where x is the value specified for system cell 146.

Known Error

CR 33896

Product

MSC / MD Nastran

Known Error

CR 33896

Corrected Version 2010.1.0 (MD R4) Abstract

Dynamic Analysis - TEMP, Thermal loads - UFM 4017 If multiple LSEQ entries exists in a model and the LSEQs reference different TIDs, then the job will fail with the following unclear messages:

Description

*** USER FATAL MESSAGE 4017 (GETEMP) THERE IS NO TEMPERATURE DATA FOR ELEMENT x IN SET yyy 0FATAL ERROR Avoidance: Reference the same TID on all the LSEQ entries.

Known Error

CR 33911

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Restarts - GKAM - Inefficient Data Recovery Restart for Modal Solutions In a data recovery restart run in SOLs 110, 111, 112, 145, and 146, the GKAM module is unnecessarily reexecuted. Avoidance: Insert the following DMAP alter in the restart run:

Description

compile semfreq alter 'call gma','' CALL GMA CASERS ,MATPOOLs,EQDYN ,TFPOOL , , , ,MAA ,GOD ,GMD , USETD ,KAA ,BAA ,K4DD ,PHsA , LAMAs ,DIT ,VAFS ,PHFA ,lamaf , AGG ,kddd / , ,CMDD ,CK2DD ,CB2DD , MHH ,BHH ,KHH ,PHDH ,VPHFS , K2MG ,M2MG ,B2MG ,K2SF ,M2SF , B2SF / LUSETD /SOLTYP /APP /NOUE /NOA / FALSE /FMODE /FALSE /FALSE /FS /

Known Error

CR 33913

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - PARAM,CHECKOUT, PARAM,GPL - Missing Output

Description

The parameter GPL described under PARAM,CHECKOUT in the Quick Reference Guide should be PARAM,PRTGPL.

Known Error

CR 33936

Known Error

CR 33936

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Aeroelastic Analysis - Mislabeled Force Output from a Trim Analysis. If there are multiple interference groups (IGID on the CAEROx entry) and the element ID's are not in ascending order with respect to the IGID's, the trim force output can have incorrectly labeled element id's since it uses monotonically ascending values starting from the lowest element ID.

Description Avoidance: Remove the multiple IGID's or make sure that element id's ascend in order with the IGID's. Known Error

CR 33938

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

RESTARTS - Inefficient Restart between binary compatible machines. If a database is created on one machine and read into NASTRAN on a different binary compatible machine, the RESTART logic may detect that there are minute differences in the model and everything may be re-calculated. Avoidance:

Description compile phase0 alter 'RMGR,RMG,/','RMGR,RMG,/' The above alter should be used only if your are certain there are no changes to the model. or superelement manual restart logic could be used. See SERST parameter. Known Error

CR 33942

Product

MSC / MD Nastran

Corrected Version GL Abstract

Documentation/Differential Stiffness - EIGR, EIGRL - Poor Rigid Body Modes

Description

If the pressurized modes of a free-free structure are desired, the rigid body modes may not be very clean and may only be separated from the flexible modes by 3 orders of magnitude. Negative values may also be observed. This condition may occur in any model with follower stiffness or rigid elements.

Known Error

CR 33942 Avoidance: No avoidance is necessary. Even though eigenvalue analysis without follower forces typically produces 6 orders of magnitude separation between the flexible and rigid body modes the answers should be acceptable.

Known Error

CR 33952

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Description

Component Mode Synthesis - PARAM,METHCMRS Does not work in SOL 107 If residual structure cms is requested and METHCMRS is used to select the eigenvalue solution method in SOL 107, the program will perform a static reduction and will ignore the request for cms. Table 1 in section 6 of the Quick Reference Guide incorrectly indicates that this parameter is supported in solution 107. Avoidance: Use the METHOD command in the CASE CONTROL to request cms for the residual structure.

Known Error

CR 33953

Product

MSC / MD Nastran

Corrected Version 2001.0.9 Abstract

Component Mode Synthesis - QSET - Wrong Answers If residual structure cms is used, unused Q-set dof are not automatically removed by AUTOSPC. This may result in unexpected or incorrect answers.

Description Avoidance: Either specify the correct number of Q-set dof (this may be difficult, as it requires prior knowledge), or use PARAM,SMALLQ,0., which will remove unused Q-set dof from the solution. Known Error

CR 33954

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - PARAM,SMALLQ - Missing Documentation

Description

PARAM,SMALLQ is not documented in the Quick Reference Guide. The purpose of this parameter is to remove unused Q-set degrees of freedom from the solution set. If you are performing residual structure qms, then it is recommended to set PARAM,SMALLQ,0. in order to remove the unused Q-set dof.

Known Error

CR 33955

Product

MSC / MD Nastran

Corrected Version GL Abstract

Elements - CBEAM, CBAR, TEMP(INIT), TEMP(LOAD) - Incorrect Beam Stresses

Description

In Version 70.5 if TEMP(INIT) references TEMPRB or TEMPP1, then TEMP(LOAD) must reference TEMPRB and TEMPP1 for the same elements, conversely if TEMP(LOAD) references TEMPRB or TEMPP1, then TEMP(INIT) must reference TEMPRB or TEMPP1 for the same elements, else wrong answers will results.

Known Error

CR 33957

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Documentation/Composites - CQUAD8, PCOMP - Poor Results The bulk data description of the CQUAD8 in the Quick Reference Guide needs to be changed as follows: - Remove Figure 1 and change the title of Figure 2 to Figure 1, - The description of the MCID field needs to be changed as follows: "MCID

Description

...................MCID coordinate system (defined by the CORDij entry or zero for the basic coordinate system) onto the surface of the element (see Remark 3). MCID is ignored ........." - Change Remark 3 as follows: "3. ........the line of constant xi." - Add the following paragraph to Remark 3: "The definition of the material coordinate system by projection is used to calculate an angle THETA. Please note that since xi changes direction throughout the element based on element shape, the material coordinate system varies similarly. Because of this an orthotropic or anisotropic

Known Error

CR 33957 material will cause the CQUAD8's stiffness to be biased by both it's shape and grid ordering. Use the QUAD4 element if a constant material coordinate system direction is desired."

Known Error

CR 33960

Product

MSC / MD Nastran

Corrected Version Abstract

Documentation/Aeroelastic UG - SOL 110 with Lagrange Multiplier Technique

Description

Section 8.11 in the Aeroelastic User's Guide demonstrates the use of the Lagrange Multiplier Technique with TPL problem ha110a.dat. Currently, solution 110 problems can not be solved reliably with the LMT approach and this example should be removed.

Known Error

CR 33973

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

DMAP - MATMOD Option 25 - Wrong Answers The form of the column vector outputs in MATMOD option 25 is 7 (labeled "ROW VECTOR") and should be 2 (labeled "ROW RECTANG.").

Description

Avoidance: Run MODTRL on the output; for example, MATMOD I1,I2,I3,,,/O1,O2/25 $ MODTRL O1// / /2 $ MODTRL O2// / /2 $

Known Error

CR 33994

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Optimization/Design Sensitivity - scr=no, DVBSHAP - UFM 1126 In Version 70.5, if shape optimization is attempted with the command line option 'scr=no', then the following fatal message occurs:

Description

*** USER FATAL MESSAGE 1126 (GNFIST) DMAP MODULE MDCASE IS ATTEMPTING TO OUTPUT DATABLOCK 201 NAME = CASESTAT, WHICH ALREADY EXISTS. USER ACTION: DELETE THE DATABLOCK, OR USE FILE CASESTAT=OVRWRT

Known Error

CR 33994 Avoidance: Insert the following DMAP alter: compile desopt alter 1 file casestat=ovrwrt $ endalter

Known Error

CR 33997

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Elements - Large Field PSOLID Entry - Stress Results at GAUSS Points, not GRID A missing PSOLID large field format continuation line will incorrectly cause stresses to be returned at the GAUSS points instead of the GRID. This will change the output values to those calculated at the GAUSS points instead of the GRID points. This could cause optimistic results to be inadvertently used for design.

Description

Avoidances: 1) Include the blank continuation line, (you may want to consider specifying the defaults so someone doesn't delete the blank line thinking it is a useless line), 2) Use sma

Known Error

CR 34005

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Description

Optimization/Design Sensitivity - Aeroelastic Analysis - Wrong Answers The Version 70.5 release of MSC/NASTRAN enabled the ability to simultaneously perform static and static aeroelastic analysis and design. It has been found that, if the static aero and static subcases both have load requests, the load calculation can become confused and incorrect or no loads can be applied in the static aeroelastic subcases. Avoidance: The only known avoidance is to not use LOAD requests in static aero subcases in situations where there are also static subcases.

Known Error

CR 34015

Product

MSC / MD Nastran

Corrected Version 70.7

Known Error

CR 34015

Abstract

Rigid Elements - RSPLINE - UFM 4204

Description

The word "WARNING" in "USER WARNING MESSAGE 4204" which warns the user that there are RSPLINE elements with no dependent degrees of freedom was inadvertently changed to "FATAL" in Version 70.5. The run continues and the results are unaffected.

Known Error

CR 34028

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Elements - CBAR, EMG, PARAM,COUPMASS - SFM 4276, EC 7777 If coupled mass is used with CBAR elements with pinflags, the run may fail with the following traceback in the EMG module: Traceback:

Description

Offset 0x00000010 in procedure zerod_ Offset 0x00000130 in procedure ebarkd_ Offset 0x000003ac in procedure emgbrd_ Offset 0x00000a08 in procedure emgpro_ Offset 0x000003c8 in procedure emg_ Offset 0x00000108 in procedure xsem09_ Offset 0x0000097c in procedure mainal --- End of call chain --Avoidance: Do not use coupled mass.

Known Error

CR 34038

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Optimization/Design Sensitivity - DESVAR, DSAJ - SFM 4276, EC 31 When a solution 200 run has both shape and sizing variables and the shape variables have smaller ids than those for the sizing variables, the job may fail in the DSAJ module with "SYSTEM FATAL MESSAGE 4276, ERROR CODE 31". Avoidance: Renumber the DESVAR ids so that the shape DESVAR have larger ids than the sizing variables.

Known Error

CR 34042

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Description

Postprocessing - GPSTRESS, PARAM,POST - Missing xdb Output If your run contains multiple subcases in nonlinear static analysis and you have requested strfield, output will only be obtained for the first subcase and subsequent subcase output will be missing. Avoidance: There is no avoidance other than performing RESTARTs for each subcase.

Known Error

CR 34043

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - ITER - Iterative Solver Support of SOL 153 not Documented

Description

The Quick Reference Guide description of the ITER bulk data entry fails to list solution 153 as a supported solution sequence.

Known Error

CR 34060

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Superelements - PARAM,METHCMRS - UFM 3032 If superelements are present and PARAM,METHCMRS is specified for the residual structure, then UFM 3032 will be issued stating that the program is unable to find the selected set (EIGRL entry). Avoidance: Insert the following alter:

Description

compile cmpmode alter 'methc\=','' if ( seid=0 and methcmrs>0 ) methc=methcmrs $ alter 'read ','' read cmkxx,cmmxx,,,dynamics,uset,cases,vyxw,sils,uset,,,eqexins/ cmlama,cmphixz,cmmi,cmoeigs,eigvmats,/ 'mode'/s,n,nozset//methf/cmset/methc $ endalter

Known Error

CR 34084

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Aeroelastic Analysis - AMP, SPC, METHOD - SFM 4276 EC 1044 QOPEN

Known Error

CR 34084 SYSTEM FATAL MESSAGE 4276. QOPEN ERROR CODE 1044 is issued in SOL 145 if BOTH the METHOD and SPC change (or are not included) for each subcase.

Avoidance: Include the same METHOD and SPC callouts in all residual subcases or place them above the subcase level. Also include the following DMAP alter: Description

compile sefluttr alter 'modefsrs','' $ change cases to casem call MODEFSRS MR,USET,DM,CASEm,DYNAMICS,MAA,KAA,GPLS,SILS,EED, EQEXINS,,pg,gm,got,kfs,ys,lll,kll/ ,,,,PHA,LAMA,PHA0,LAMA0/ app/NORSET/NOASET/false/ 0/NOASET/METH/0/true/NOQSET/nsub/0 $ alter 'call setq','' CALL SETQ CASE1// SEID/PEID/S,MTEMP/S,K2GG/S,M2GG/S,B2GG/S,MPC/ S,SPC/S,LOAD/S,DEFORM/S,TEMPLD/S,P2G/S,

Known Error

CR 34089

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Composites - RESTART, PCOMP, DBLOCATE - Infinite CPU Loop If PCOMPs are changed in a RESTART and there is more than one PCOMP entry in the model, then the run may enter an infinite cpu loop in the DBLOCATE module. Avoidance: You can avoid the error with the following DMAP alter.

Description

malter 'ept,eptr','ept,eptr' restart ept,,/list/ $ malter 'epts,eptsr','epts,eptsr' restart epts,,/hists/ $ This alter will redo the entire analysis. Only use this alter if there is a difference in the number of plies between the restart pcomp card and the new pcomp card.

Known Error

CR 34114

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Optimization/Design Sensitivity - PARAM,OPTEXIT,3 - Missing Output PARAM OPTEXIT 3 is used to exit SOL 200 after evaluating the constraints. However, the results of this evaluation are not printed, making this option of marginal utility. These prints could be of particular benefit if the user has synthesized a response that is not currently available with standard output requests. The user could see the values of the response, but avoid costly sensitivity/optimization calculations.

Description

Avoidance: The following dmap alter provides the P2 output (see the DOPTPRM bulk data entry) when PARAM OPTEXIT= 3 compile desopt $ alter 'optexit=3'(,-1) $ if ( descycle=1 ) DOM10 DESTAB,XINIT,,CNTABRG, CVALRG, , DVPTAB,PROPI,,R1TABRG,R1VALRG,, RSP2RG,R2VALRG,,OPTPRMG,OBJTbg,DRSTBLg,

Known Error

CR 34139

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Dynamic Analysis - LSEQ, STATSUB - Missing UWM 3204 If a dynamic response analysis specifies a static subcase but then in the dynamic subcase the dynamic loads are incorrectly applied such that the LID field of the LSEQ entry references non-existant static load entries, no warning message will be issued and unexpected answers will result. The following user warning message should be issued:

Description *** USER WARNING MESSAGE 3204 (SSG1) UNABLE TO FIND SELECTED SET ( yy) IN TABLE (SLT ) IN SUBROUTINE (SSG1). Avoidance: Other that ensuring that the static load entries exist, there is no avoidance. Known Error

CR 34151

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Miscellaneous - Unknown Error Message, Lost some, 2206 of 2209 eliminated

Description

When the new reordering methods are used, it is possible that the message "Lost some, 2206 of 2209 eliminated" (the numbers may not be the same)

Known Error

CR 34151 may be written to the f04 and the job will stop. This appears to happen when the EXTREME reordering is used and insufficient memory is available. This has only been observed in two client runs. Avoidance: If the message above is encountered, disable the EXTREME method by setting SYSTEM(206) to 1, 8, or 9

Known Error

CR 34153

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Description

Optimization/Design Sensitivity - PCOMP - UFM 6482, Response Types Mislabeled If a composite type response (CSTRESS,CSTRAIN, or CFAILURE) is invoked in a subcase that does not support this type of response (e.g, ANALYSIS=MODES). The designated response type is scrambled; CFAILURE becomes CSTRESS, CSTRAIN becomes CFAILURE, and CFAILURE becomes CSTRAIN. Further, RTYPE CFAILURE is misspelled CFAIURE in USER FATAL MESSAGE 6482. Avoidance: The FATAL message is legitimate, but one needs to infer the correct response type.

Known Error

CR 34200

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Description

Geometric Nonlinear Analysis - CHEXA, CQUAD4, CTRIA3, TEMP(LOAD) Wrong Answers In sol 4, ssg1 puts out an incorrect load vector for CHEXA, CQUAD4 and CTRIA3 elements when thermal loads are present along with a global output system. Avoidance: Use solution 106 or 64.

Known Error

CR 34208

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Optimization/Design Sensitivity - TA1 - SFM 3001

Description

When a design variable overrides an analysis property in a p-element sizing

Known Error

CR 34208 optimization job, it results in the following error message: SYSTEM FATAL MESSAGE 3001 (TA1) THE INPUT DATA BLOCK NAMED EHT AT POSITION 10 DOES NOT EXIST. Avoidance: Ensure that property values for both the analysis and design model are identical or apply the following dmap alter. compile desopt alter 'luset= ' DBVIEW eht0=eht (WHERE DESITER=0) $ EQUIVX eht0/eht/always $ DBVIEW ehta0=ehta (WHERE DESITER=0) $ EQUIVX ehta0/ehta/always $ DBVIEW gdntab0=gdntab (WHERE DESITER=0) $ EQUIVX gdntab0/gdntab/always $ DBVIEW medge0=medge (WHERE DESITER=0) $ EQUIVX medge0/medge/always $ DBVIEW mfac

Known Error

CR 34211

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Shape Optimization - DBLOC, DVSHAP, MATGEN - UFM 6962 When performing shape optimization using an external database for basis vectors, if the dblocated basis vectors (UGD) do not have same GSET size as the analysis model, then the following fatal message will occur:

Description

USER FATAL MESSAGE 6962 (MATGEN) ILLEGAL VALUE FOR PARAMETER 3 = **** Avoidance: Use an external model displacement vector (UGD) compatible with the current analysis model GSET size.

Known Error

CR 34236

Product

MSC / MD Nastran

Corrected Version GL Abstract

Installation/Authorization - FlexLM Failing on NEC SX4 with SIGALARM error -5038

Description

There is a problem on the NEC SX4 machine using the FlexLM network licensing manager that may cause large jobs to fail with the message: SIGALARM Alarm

Known Error

CR 34236 call 5038 error. Avoidance: There is no avoidance, use a node lock authcode instead.

Known Error

CR 34238

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Description

Elements - PBEAM, PBAR, IFP - SFM 4276, EC 7777 HP systems may have fail with a traceback in IFP when it attempts to read bulk data inputs that contain PBAR and/or PBEAM input with very large property values. Avoidance: There is no avoidance.

Known Error

CR 34239

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - TLOADi - Missing Documentation

Description

A remark under the description of the TLOADi entries in the Quick Reference Guide indicates that if time dependent loads are applied in a frequency response solution, that a Fourier transform is performed to transform the loads to the frequency domain and that the results are converted and reported in the time domain. This remark should refer the user to the Section 5.4 in the Advanced Dynamics User's Guide to obtain more information on the process.

Known Error

CR 34254

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Iterative Solver - ITER, BIC - Poor Performance, Poor Convergence If an initial guess is given to the iterative solver with BIC preconditioning (default) in MSC/NASTRAN V70.5 it will be ignored.

Description

avoidance: To be able to use an initial guess with the Version 70.5 set PRECOND=BICWELL or PRECOND=BICILL on the ITER Bulk Data entry and set SYSTEM(241)=2000 on the NASTRAN entry.

Known Error

CR 34259

Product

MSC / MD Nastran

Known Error

CR 34259

Corrected Version 2001.0.1 Abstract

Acoustic Analysis - Superelements - UFM 9101 When a fluid only model with a fluid superelement is run in solution 103, the job may fail with the following messages:

Description

^^^ BULK DATA AND CASE CONTROL PARTITIONING, RESTART CHECKING, AND UNDEFORMED PLOTTING IS ^^^ INITIATED FOR SUPERELEMENT 0 ^^^ USER FATAL MESSAGE 9101 (PHASE0) ^^^ FLUID ELEMENTS ARE DETECTED IN THIS SUPERELEMENT. ^^^ USER ACTION: ENSURE THAT ALL FLUID ELEMENTS ARE ASSIGNED TO SUPERELEMENT yy Avoidances: 1) Do not use a superelements for this analysis, it is not needed. This may require stripping the superelement designation from all of the fluid grids if the model comes from a fluid/structure analysis. 2) Add a dummy structural element similar to the following: grid, 10000 $ token grid point in se 0 celas2,

Known Error

CR 34264

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Description

Estimate - File Names may not Contain Blanks Blanks in pathnames are not handled properly when "memory=estimate" is specified. Only the part of the directory name after the blank is shown and estimate issues the message "This file does not exist." The job continues, but the default memory or buffsize is used. Avoidance: Specify a pathname that does not include blanks.

Known Error

CR 34265

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation/Superelements - PARAM,MINIGOA - Undocumented Parameter

Description

In MSC/NASTRAN Version 70, an undocumented parameter (MINIGOA) was

Known Error

CR 34265 added to allow reduction in the amount of disk space used when using superelements. When this parameter is used, the transformation matrix (GOA) will contain terms only for the degrees of freedom defined in the U5 (USET, USET1, SEUSET, SEUSET1) set. As the GOA matrix is often one of the largest matrices stored in the database, this can allow for a significant reduction in the amount of disk space used. The limitation of using this approach is that data recovery will be available only for these degrees of freedom and the elements connected to them.

Known Error

CR 34266

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - EIGRL - SYSTEM(273) Not Documented in the QRG

Description

In Version 70.5, setting SYSTEM cell 273 to 1 allows the selection of the old (pre-v70.5) Lanczos eigensolver. This is mentioned in the Version 70.5 Release Guide, but is not documented in the QRG.

Known Error

CR 34270

Product

MSC / MD Nastran

Corrected Version GL Abstract

P-Elements - Wrong Answers for p-BEAM Element at p=1

Description

BEAM p-elements with p-order of 1 are stiffer in bending than BEAM helements due to incorrect residual bending flexibility in BEAM p-elements. Avoidance: The avoidance is to start at a p-order of 3.

Known Error

CR 34271

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Optimization/P-Elements - P-BEAM - Wrong Results in OES1 Table

Description

Wrong ENDB max and min stresses are written to the OES1 table for the pBeam element types by Module SDRP. However, the OFP printout of the ENDB max and min stresses is correct since the OES1 table values are not read but computed by the OFP module. This error will affect design optimization results

Known Error

CR 34271 and postprocessors which report these values. Avoidance: There is no known avoidance.

Known Error

CR 34287

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Description

Aeroelastic Analysis - Incorrect Stability Derivative Sensitivities The UXU and UXR matrices produced by DSARLP may be in error. Consequently, this can produce wrong answers for the sensitivities of stability derivatives and will produce unpredictable downstream errors. Avoidance: There is no known avoidance. This capability should be used with caution. Zero or unreasonable stability derivative sensitivities may be an indication that this error has been encountered.

Known Error

CR 34290

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation/QRG - TABLES1 - Discontinuity is not Allowed, UFM 316

Description

The Quick Reference Guide description for the TABLES! entry should explicity state that discontinuities are not allowed and will lead to a fatal message.

Known Error

CR 34325

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

P-Elements - GMLOADs on FEEDGEs with p=1 may give bad answers

Description

GMLOADs on FEEDGEs with p=1 will give incorrect loads if another edge with p>1 was processed. Avoidance: There is no known avoidance.

Known Error

CR 34362

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

P-Elements - Incorrect p-shell Output with PROJ=F Option

Description

If the PROJ=F option is chosen on the OUTRCV entry for p-shells, the moments

Known Error

CR 34362 may be incorrect. In addition, if a coordinate system is specified with the CID=n option, the transformation may be incorrect. Note that the PROJ=F option does not output any data into the f06 file, but it does affect the output in the OP2 and XDB files. The option was created primarily for use by MSC/ARIES.

Known Error

CR 34393

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Utilities - xdb, DBC - msc2ptc Failed to work for NASTRAN Version 70.5 The msc2ptc utility does not run due to a problem with the nast705 script and missing m2p.dsc file. An attempt to convert the xdb file fn.xdb results in the message:

Description

fn: executable for fn not found or not executable. Verify that the fn executable has been installed. The full pathname of the bracket executable is: /nastran705/msc705/solaris/fn

Avoidance: The updated files are posted at http://www.macsch.com/support/support.html Known Error

CR 34415

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Superelements - EPOINT - Wrong Answers In part superelements with extra points, the sequence of grid points provided in the usetd table, produced from the uset table by adding extra point data, may differ. This will cause plausible but wrong answers. In one example discovered in testing the load vectors were in a different sequence than the corresponding terms in the stiffness matrix.

Description

Avoidance: An avoidance which prevents the error is to put in at least one SEQGP entry for a residual structure grid point. It can be input in a manner that will cause no extra resequencing of the model. For example, if the main bulk data file includes grid point 47, the following SEQGP entry will suffice: SEQGP, 47, 47.1

Known Error

CR 34415 This avoidance may be used with any model, of any size, with negligible effect on cost. The presence of an SE

Known Error

CR 34424

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

File Management Section - DBDICT May Fail to List All Keys NDDL datablocks are uniquely defined by their qualifier values. In addition to the NDDL datablock name, a path, or list of applicable qualifiers, is thus used to "point" to a particular datablock. The DBDICT FMS statement (which can also be called in DMAP) can be used to list qualifier values for datablocks stored on the database, and does so by printing out "keys," or unique lists of qualifiers and their values. A code error may prevent some of the keys from being printed out. Avoidance: If this problem is encountered, the DBDIR FMS statment (also callable in DMAP) can be used to obtain a complete qualifier listing.

Known Error

CR 34429

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Miscellaneous - Overflow "*****" in the f04.

Description

If a job requires more than 999999.9 CPU seconds, then the F04 will print ********. If a job requires more than 999999.9G of I/O then ******** will be printed. Avoidance: There is no avoidance.

Known Error

CR 34459

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Heat Transfer - Missing RADLST Information in Punch File If large CHBDYG id's exist, then the punch file which contains the RADLST entries will be incomplete and contain a line such as: RADLST 12 1****************

Description Avoidance: 1) Do not use element ID greater than 10000001 2) Use restart for the subsequent run rather than including the RADLST punch file because all the radiation matrix information is in the NASTRAN database. Known Error

CR 34462

Known Error

CR 34462

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Description

P-Elements - HEXA - Poor Answers, Element too stiff when modeling thin plate The HEXA element with p=1 on most edges is too stiff. This was discovered when analyzing the thin flat plate test problem of the MacNeal Harder test set. For most problems the effect is small, but for the thin flat plate model the effect is dramatic. Avoidance: Use a higher p-order.

Known Error

CR 34467

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

P-Elements - CHEXA, CPENTA, CTETRA - Wrong Answers for Transformed Stresses If stresses and strains are being transformed using the CID= keyword in the OUTRCV bulk data entry, then wrong answers may result.

Description

Avoidance: The only avoidance is to request the stresses in the basic (default) coordinate system.

Known Error

CR 34474

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Security - FLEXlm License may be Refused by the nastran Command The nastran command will refuse to accept an otherwise valid FLEXlm license spec for redundant servers written as: port@host1,port@host2,port@host3 Avoidances:

Description

1) Do not use redundant servers. They are high maintenence with little gain. Multiple servers, specified via "port@host1:port@host:..." on UNIX and "port@host1;port@host;..." are more powerful and less work. 2) Only specify one of the hosts. Each of the hosts in the quorum knows about the other two, so the comma specification is redundant. You could even specify all three hosts as if they weren't redundant, using the ":" or ";" separators as appropriate.

Known Error

CR 34480

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Description

Eigenvalue Analysis - PARAM,RESVEC,YES - Missing Eigenvalues By simply specifying PARAM,RESVEC,YES, incorporated residual flexibility in the solution sequences making the the resflex sssalter unnecessary. There is an error in the capability which may cause missing modes. The error in the results is obvious because there will be fewer rather than more eigenvalues when you compare the eigenvalues "BEFORE AUGMENTATION OF THE RESIDUAL VECTORS" to those "AFTER AUGMENTATION OF THE RESIDUAL VECTORS".

Avoidance : Insert the following DMAP alter: compile resvec alter 'if ( noxset'(3),'' if ( noxset>-1 or append ) then $ endalter Known Error

CR 34482

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

DMAP - Database, DBSTORE - DBSTORE Does not Function on RESTART The automatic restart logic does not schedule modules to run on restart that have no output data blocks. The dbstore subdmap, and the dbstor subdmap which it calls, have this attribute.

Description Avoidance: Use putsys(1,109) before the call statement, or use an alter in the v70.5 sssalter library that includes dummy output data blocks for both modules.

Known Error

CR 34491

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Description

Delivery Database - eie layer unable to extend file On Cray systems, if a user has the Delivery Data Base (SSS*) files on a device that does not have a sector size that is a multiple of 4096 words, and if the user specifies ff_io_defaults=eie.sds.diag, then the following message is printed:

Known Error

CR 34491 eie layer unable to extend file "/apps/mscnast/v7052/msc705/unicosts/SSS.MASTERA" to a multiple of 65536 bytes /apps/mscnast/v7052/msc705/unicosts/SSS.MASTERA : open failed : errno =5048 : Unknown error ffopen(/apps/mscnast/v7052/msc705/unicosts/SSS.MASTERA) using alternate layers system opening layer system /apps/mscnast/v7052/msc705/unicosts/SSS.MASTERA : using layers : syscall The job will then continue to run if the the BUFFSIZE is 4097. However, if BUFFSIZE is set to a different value, then the following error is printed:

Known Error

CR 34517

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Description

P-Elements - STRAIN, SHELLS & SOLIDS -- Incorrect Principal and von mises strain If a problem has either shell or solid p-elements, then the principal, von Mises, and mean pressure strains may be incorrect. Avoidance: There is no avoidance.

Known Error

CR 34520

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Acoustic Analysis - METHOD(STRUCTURE) - Wrong Answers In fluid/structure analysis, in modal frequency response (SOL 111), if the fluid modes are calculated using the modal method, i.e. the case control command METHOD(FLUID)=n, but no METHOD(STRUCTURE) is specified, incorrect results occur.

Description

Avoidances: 1. Use SOL 108, or, 2. use both a METHOD(FLUID) and a METHOD(STRUCTURE), or, 3. put the fluid in a superelement and process it separately, or 4. use the following alter for Version 70.5: compile gma

Known Error

CR 34520 alter 295 partn k1dd,vafse,/k1shh,,, $ partn kddd,vafse,/kdhh,,, $ igh=ig $ call xadd5 k1shh,kdhh,,,/gk1shh/igh/cu/cz/cz/cz $ endalter $

Known Error

CR 34523

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Optimization/Design Sensitivity - DEQATN - SFM 4276 Optimization runs with large DEQATN entries that are near or exceed the limit of 32000 non-blank charachters may fail on Cray computers with the following message: lib-1190 /u/app/nastran/msc/msc705/unicosc90/NAST705: UNRECOVERABLE library error A numeric input field contains an invalid character.

Description

Encountered during a sequential formatted READ from an internal file (character variable) Error initiated at line 656 in routine '_rdfmt'. SIGNAL - Signal SIGABRT(6) caught, job aborting. See signal(2), CRI manual SR-2012 for further information. Beginning of Traceback: Called from line 42 (address 15624627c) in routine 'TRBK'. Called from line 39 (address 132322c) in routine 'RECOVR'. Called from line 112 (address 15073635b) in routine 'sysrcv'. Called from

Known Error

CR 34535

Product

MSC / MD Nastran

Corrected Version GL Abstract

Optimization/Design Sensitivity - PCOMP, MAT8, SDRCOMP - UWM 2020, UFM 5503

Description

In solution 200, if ply failure indice responses are requested for a composite element whose PCOMP entry references a material entry that does not define the composite failure allowables for one or more of the plies, then the

Known Error

CR 34535 following fatal and/or warning messages are issued and the failure index responses are not used for that element in the optimization analysis. ** USER FATAL MESSAGE 5503 (DSAD13) ELEM NO. 42649 PLY NO. 1 REFERENCED ON A DRESP1 ENTRY COULD NOT BE FOUND. *** USER WARNING MESSAGE 2020 (SDRCOMP) ONE OR MORE OF THE ALLOWABLE STRESS CONSTANTS WERE INCORRECT FOR ELEMENT 1 PLY 4 ELEM NO. 1 PLY NO. 1 REFERENCED ON A DRESP1 ENTRY COULD NOT BE FOUND. USER ACTION: CHECK THE ELEMENT IDS REQUESTED ON THE DRESP1

Known Error

CR 34548

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Acoustic Analysis - EPOINT, CAABSF - SFM 6719 (MRGIDX) In frequency response, if EPOINTs exist in a fluid-only analysis with CAABSF elements with no SPCs, the following fatal message will be encountered: *** SYSTEM FATAL MESSAGE 6719 (MRGIDX) MATRICES HAVE DIFFERING NUMBERS OF ROWS: [A] = 48 x 48 [B] = 44 x 44 [C] = 48 x 48 [D] = 48 x 48 0FATAL ERROR

Description

Avoidance: Insert the following DMAP alter or add a dummy grid point and constrain all of its degrees-of-freedom. compile fdrmgen alter 'if ( noa','' type parm,,i,n,noue $ if ( noa=-1 and noue=-1 ) then $ compile freqrs alter 'if ( noa'(3),'' IF ( noa>-1 or noue>-1 ) then $ endalter

Known Error

CR 34552

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Acoustics - EPOINTs, GMA, GKAM - Fails with no message

Known Error

CR 34552 If EPOINTs are used in a fluid-only model in solution 111, the run will fail without message after the eigenvalue extraction and before the frequency response output. Avoidance: Use the following alter:

Description

compile gma alter 'gkam' if ( fonly and noue>-1 ) then $ matgen ,/iee/1/noue $ paraml phfa//'trai'/1/s,n,nohset $ paraml phfa//'trai'/2/s,n,noaset $ type parm,,i,n,nhe,nae $ nhe=nohset+noue $ nae=noaset+noue $ matgen ,/vhe/6/nhe/nohset/noue $ matgen ,/vae/6/nae/noaset/noue $ merge phfa,,,iee,vhe,vae/phdfh/1 $ merge MFHH,,,,vhe,/mfhh1 $ equivx MFHH1/mfhh/-1 $ merge K1FHH,,,,vhe,/k1fhh1 $ equivx K1FHH1/k1fhh/-1 $ endif $ fonly and noue>-1

Known Error

CR 34558

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

P-Elements - BEAM, OUTRCV - Wrong Answers at View Points

Description

The results output at view points for beam p-elements is wrong if a curved coordinate system is specified as the output coordinate system on the OUTRCV entry.

Known Error

CR 34581

Product

MSC / MD Nastran

Corrected Version Abstract

Description

Heat transfer - VIEW3D - FATAL, DIMENSION LENGTH x IS SMALLER THAN "VFZTOL" It is possible running a view factor calculation using the VIEW3D module (this is the default view factor method selected by PATRAN) to encounter the message: *** FATAL *** DIMENSIONAL LENGTH: 1.732432600E-11 IS SMALLER THAN

Known Error

CR 34581 "VFZTOL": 1.000000013E-10 REASSIGN "PARAM,VFZTOL,X.XE-XX" TO BE SMALLER THAN THE DIMENSIONAL LENGTH. Avoidance: Comment out the VIEW3D input so that the older view factor module is used. In the test problem that encountered the poor message, the old view factor module issued the messages below which identified the problem: *** USER FATAL MESSAGE 4528 (VNASIN) ERROR IN CHBDY CARD xx AN AREA4 ELEMENT MUST BE A QUADRILATERAL CONTAINING NO ANGLE GREATER THAN OR EQUAL TO 180 DEGREES. THE GRID POINTS MUST BE SPECIFIED SEQUENTIALLY AR

Known Error

CR 34585

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Database - SFM 1041 (GALLEX) A limit in the database directory size may cause large jobs to fail with the message SYSTEM FATAL MESSAGE 1041 (GALLEX).

Description

Avoidance: This limitation can be overcome by increasing the buffsize and/or setting system(158)=1000 and system(159)=500 to allow for a larger expansion of the database.

Known Error

CR 34590

Product

MSC / MD Nastran

Corrected Version GL Abstract

Eigenvalue analysis - EIGB, SINV, CYCLIC4 - SFE 4276, FREAD EC 3002 In SOL 16, cyclic buckling, if the SINV method is used, and no eigenvalues are found for the current harmonic, then the run fails with the following message in CYCLIC4.

Description *** SYSTEM FATAL ERROR 4276.FREAD ERROR CODE 3002 PID= 0 Avoidance: Use the Lanczos method. Known Error

CR 34591

Known Error

CR 34591

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Cyclic Buckling - SOLs 116 and 16, CYSUP - SFM 3001 and UFM 1126 The use of CYSUP in SOL 116 causes SFM 3001 in UPARTN. In SOL 16, if eigenvalues are requested at more than one harmonic, then UFM 1126 in CYCLIC3 is issued.

Avoidance: Insert the DMAP alter: Description

compile sol16 alter 1 file pvec=save,ovrwrt $ COMPILE MODECYC $ ALTER 'CALL *MODERS'(,-1) $ DELETE /MR1,,,, $ REACT = -1 $ endalter

Known Error

CR 34592

Product

MSC / MD Nastran

Corrected Version 2004.0.7 Abstract

Aeroelastic Analysis/Random Analysis - EPOINT - Missing Random Output Random analysis with an aeroelastic model fails to yield the acceleration random output if any random output requests for EPOINT dofs are made.

Description

Avoidance: Make two separate runs, with the epoint data recovery being requested in a separate runs. The runs will be more efficient if restart is used.

Known Error

CR 34602

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Frequency Response - STRESS(BILIN), STRESS(CORNER) - Wrong Answers

Description

Complex corner stress output for QUAD and TRIA elements is incorrect in MSC/NASTRAN Version 70.5.2. The value for the real part of the stress at the grid point will be overwritten with the imaginary value. The results at the center of the element are not affected.

Avoidance: Other than not requesting the corner stress option, there is

Known Error

CR 34602 no avoidance.

Known Error

CR 34604

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

P-elements - Estimate - Over-prediction of Resources

Description

MSC/ESTIMATE may predict significantly more resources than required for P-elements. This over-prediction is partially a result of the uncertainty of the P value. Avoidance: Do not use MSC/ESTIMATE for P elements.

Known Error

CR 34613

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Cyclic Symmetry - LOADCYN - UFM 4342, Job Aborts If a cyclic symmetry job encounters the fatal message: USER FATAL MESSAGE 4342 (CY1BLD) THE LOAD BULK DATA CARD GIVEN BELOW IS INCONSISTENT WITH SPECIFIED ANALYSIS HARMONICS OR SEGMENT OR SYMMETRY TYPE. then the job will not produce an "END OF JOB" and will issue the traceback below: Traceback:

Description

Offset 0xffffffff in procedure Offset 0x0000014c in procedure WriteUnit Offset 0x00001094 in procedure _xlfWriteFmt Offset 0x00000884 in procedure cy1bld_ Offset 0x0000063c in procedure cy1ccl_ Offset 0x000008c8 in procedure cycl1_ Offset 0x00000114 in procedure xsem12_ Offset 0x000009a0 in procedure mainal --- End of call chain --Avoidance: Although the job should not issue a traceback, the fatal message output is correct and the user should cor

Known Error

CR 34652

Known Error

CR 34652

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - RFORCE, CTRIAX6 - METHOD 1 and 2 Produce the Same Loads Remark 9 in the MSC/NASTRAN V70.5 Quick Reference Guides for the RFORCE bulk data entry states:

Description

9. METHOD=2 should be used for the CTRIAX6. METHOD=1 produces null loads. This is incorrect. Method 1 produces the same loads as method 2.

Known Error

CR 34665

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Estimate - Nonlinear, HEXA, PENTA, TETRA - Under-predicts Memory

Description

In a NonLinear analysis (SOL 66, 99, 106, 129, 153,159) the ESTIMATE utility erroneously assumes the rotational degrees of freedom are fixed for grids attached only to 3-dimensional elements. The result is that the memory and disk requirements may be under-predicted.

Known Error

CR 34666

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Optimization/Design Sensitivity or Superelement- GENEL - Possible Wrong Answers If the number of GENEL's is an odd number greater than 1, the stiffness terms produced by the GENEL's will be in error on the second and subsequent design cycles in SOL 200. Similarly, in other solution sequences, having GENELs in more than one superelement, or in a superelement and residual structure can result in some of the GENELS not generating their respective stiffness matrices which will lead to wrong answers.

Description

Avoidance: Insert the following dmap alter. compile semg1 $ alter 1 $ type parm,,i,n,nsize $ alter 'sma3.*nogenl','' $ if ( nokggx 1) is wrong when there exists a temperature dependent material property. Avoidance: Other than ignoring the intermediate output there is no avoidance.

Known Error

CR 34833

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Frequency Response - Corner Force - Missing or Wrong Corner Force

Description

If corner force output ( stress(corner...)=x ) is requested in a frequency response analysis, the corner force for the QUAD4 will either be missing or incorrect. This error has been corrected for Version 70.5. Avoidance: Use the center stress.

Known Error

CR 34834

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Description

Eigenvalue Analysis - PARAM,RESVEC - Wrong Answers If a C-set is defined for a superelement, the component modes are passed thru a filtering process to remove any which might be a linear combination of the static transformation. In V70, if residual vectors are not requested, the component modes will not be passed thru the filter. This may lead to either rank-deficient matrices or wrong answers. If the filtering is not performed, the reduced stiffness matrix will incorrectly contain the original eigenvalues on the diagonal and there will be no off-diagonal terms (as there should be if the filtering is not performed). Avoidance: If residual vectors are requested with at lease one loading

Known Error

CR 34834 or U6-set dof defined, then the filtering will be performed. Otherwise, use Version 70.5 or later version.

Known Error

CR 34874

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Eigenvalue Analysis - PARAM,RESVEC, Superelements - Poor Answers If residual vectors are requested in dynamic analysis (PARAM,RESVEC,YES) and none are appended, the original modes will be lost without warning. The user should also see related error 34480.

Description

Avoidance: Either do not include residual vectors, make sure that residual vectors are calculated, or include the following DMAP alter: compile resvec alter 'WERE AVAILABLE AFTER FILTERING' equivx phx/aphx/-1 $ equivx lama/alama/-1 $ endalter

Known Error

CR 34902

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Optimization/Design Sensitivity - CBUSH, CVISC, CDAMP - UFM 1126 Optimization (SOL 200) produces User Fatal Messages 1126 when damping element properties ( CDAMP, CVISC, CBUSH) are active design variables and superelements are used in the model. Avoidance: Apply the following DMAP alters:

Description

compile desopt alter 'type DB' type db belmdsf, bdictdsf, belmdsb, bdictdsb $ alter 'dopr5' type db zuzr01 equivx tabdeq/zuzr01/always $ compile fea list alter 'type parm' type db zuzr01 alter 'dspt1'(2),'dspt1'(2) PARAML zuzr01//'TRAILER'/1/S,N,NDVAR $ no. of des. var. alter 'dspt1'(3),'dspt1'(3)

Known Error

CR 34902 PARAML zuzr01//'TRAILER'/1/S,N,NDVAR $ no. of des. var. matprn zuzr01 // $ alter 'trd2'(2),'trd2'(2) TRD2 CASERS,TRL,NLFT,DIT,KHH,BHH,MHH,PHT,zuzr01,,,/ UHTDS,,TOLSCR/ SOLTYP/NOUE/NONCUP/0 $ COMPILE PSLGDV alter 'emg,'(3),'

Known Error

CR 34925

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - QRG - DISPLACEMENT Remark 2b for the DISPLACEMENT Case Control Command should be modified from

Description

SORT2 is the default in transient response analysis (structural and heat transfer). SORT2 is not available for real eigenvalue (including buckling) complex eigenvalue, or flutter analysis. If SORT1 is selected for one or more of the commands ACCE, DISP, ENTH, FORC, HDOT, MPCF, OLOA, SPCF, STRA, STRE, and VELO than the remaining commands will also be output in SORT1 format. to

SORT2 is the default in transient response analysis (structural and heat transfer). SORT1 is the default in frequency response analysis. SORT2 is not available for real eigenvalue (including buckling), complex eigenvalue, or flutter analysis. If SORT1 is selected in a transient solution for one or more of the c Known Error

CR 34926

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Superelements - SEALL - SEP2DR, Logic error 110

Description

If the SEALL command refers to an undefined superelement, directly or via the SET command, then the run terminates with "SEP2DR LOGIC ERROR 110". Avoidance: Correct the undefined superelement references.

Known Error

CR 34940

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Nonlinear Heat Transfer - RADBC, NLITER - SFM 4276, Traceback In the radiation dominate problem, the stiffness term is approximately equal to 4*T**3. Therefore, if the guess at the initial temperature value is too low for the problem, the temperature may rapidly exceed an infinite value and the traceback that follows will occur:

Trap encountered: SIGTRAP - Trace trap FP overflow Traceback:

Description

Offset 0x00000014 in procedure zerod_ Offset 0x00000564 in procedure nrdbcd_ Offset 0x00001124 in procedure nlemg_ Offset 0x00000780 in procedure nliter_ Offset 0x00000088 in procedure xsem15_ Offset 0x00000990 in procedure mainal --- End of call chain --Avoidance: Make a better estimate of the initial temperature on the TEMPD bulk data entry. In general it is safer to have a very high initial temperature than too low The deck with default temperature=0.0 ran to the end without errors on v2005t1 of AIX and LINUX platforms.

Known Error

CR 34949

Product

MSC / MD Nastran

Corrected Version Abstract

Plotting - XYPLOT - Bad Scaling of XYPLOT data The XYPLOT capability fails to scale the xy-plots properly when small values of displacement exist in the entire frequency range of interest.

Description Resolution/Avoidance: Use Microsoft Excel to plot the data or scale the model so the response values are not so small. Known Error

CR 34956

Product

MSC / MD Nastran

Corrected Version

Known Error

CR 34956

Abstract

Aeroelastic Analysis - Panels in XY Plane Produce a Singular Matrix

Description

The Quick Reference Guide AERO and AEROS descriptions caution against placing a lifting surface in the plane of symmetry. The problems associated with this modelling practice in the XZ plane of symmetry have been removed in Version 70.6. However, the XY symmetry was not addressed so that vehicles flying in ground effect (SYMXY=-1) with any panel or body in the XY plane still produce a singular matrix. The user is also cautioned not to attempt to perform a SYMXZ=1 (symmetric) analysis with ALL panels and bodies on the XZ plane.

Known Error

CR 34967

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Eigenvalue Analysis - PARAM,RESVEC - PARAM,RESVINER Ignored If PARAM,RESVINER,YES is specified to calculate residual vectors for the inertial loads due to the unit acceleration of mass and there are no LOADSET-LSEQ loadings or U6 set degree of freedom, then PARAM,RESVINER,YES will be ignored. This may lead to poor answers. Avoidance: Include the following DMAP alter for V70.5

Description

compile semodes alter 'call modef','' CALL MODEFSRS MR,USET,DM,CASEM,DYNAMICS,MAA,MKAA,GPLS,SILS,EED, EQEXINS,,PG,GM,GOT,KFS,YS,LLL,KLL, bgpdts,scstm,cstms,medge/ ,,,,PHA,LAMA,PHA0,LAMA0/ APP/NORSET/NOASET/FALSE/0/NOASET/METH/METHF/TRUE/ NOQSET/NSUB/0 $ compile modefsrs alter 'subdmap','' SUBDMAP MODEFSRS MR,USET,DM,CASES,DYNAMICS,MAA,KAA,GPLS,SILS,EED, EQEXINS,VAFS,PG,GM

Known Error

CR 34969

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Optimization/Design Sensitivity - EMG - UFM 4659, UIM 4656 from EHEXD

Known Error

Description

CR 34969 When superelements are used in a shape optimization task with solids elements, the job may fail in EMG during the sensitivity analysis phase with the user fatal messages: UFM 4659 and UIM 4656 from routine EHEXD. Other similar error message may also be issued depending on the type of elements being used in the model. Avoidance: Do not use superelements.

Known Error

CR 35007

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Optimization/Design Sensitivity - PARAM,DDRMM,0 - UFM 5629, UFM 9058 If PARAM,DDRMM,0 is specified in SOL 200 with ANALYSIS=MFREQ or MTRAN, then the run will fail with UFM 5269 or UFM 9058, respectively. Avoidance: Insert the following DMAP alter:

Description

compile fea alter 'delete \/msf1,bsf1,ksf1,,'(,-1) if ( drmm ) drmm=false $ alter 'IF ( DROPT\=2'(2) delete /msf1,bsf1,ksf1,, $ IF ( DOSPCF ) call CFORCE1 MSF,M2SF,BSF,B2SF,KSF,K4SF,K2SF,,/ msf1,bsf1,ksf1/ APP/APP/false $ delete /MMG1,BMG1,KMG1,, $ IF ( DOMPCF ) CALL CFORCE1 MMG,M2MG,BMG,B2MG,KMG,K4MG,K2MG,,/ MMG1,BMG1,KMG1/ APP/APP/true $ alter 'destrn\=true'(,-1),'destrn\=true'(,2) alter 'ELSE if ( drmm )' destrn=true $ drmm=false $ endalter

Known Error

CR 35029

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Postprocessing - DBC - LAMA Objects have Incorrect Attributes in the XDB

Description

When subcases in optimization refer to eigenvalue or buckling analysis,

Known Error

CR 35029 the LAMA objects in the XDB will have incorrect attributes and this may effect the ability of other products such as MSC/InCheck to process the results. In addition, if a frequency range is specified rather than an explicit number of modes, NASTRAN DBC translation may be incorrectly terminated.

Known Error

CR 35040

Product

MSC / MD Nastran

Corrected Version 2007.0.0 (MD R2) Abstract

Static Analysis - SORT2, PUNCH - Punch Output has Zero Results If SORT2 is requested for static analysis results, zero results are written to the PUNCH file. Avoidance: The following DMAP alter uses OFP to write the data in f06 format to an alternate fortran unit thus avoiding the punch unit.

Description

$ $ Output of QUAD4 Element Stress data $ for post-processing of printed stress in $ a fortran unit separate from the usual $ f06 file. $ COMPILE SEDRCVR,SOUIN=MSCSOU,NOLIST,NOREF ALTER 'OFP.*OES2S,OSTR2,,,,,','' $ type parm,,i,n,linespp $ linespp=getsys(linespp,9) $ paraml kelm//'trailer'/1/s,n,noelem $ No. of nl elem. in model noelem=20*noelem $ calc. lines per page to 20 x no. of elem. putsys(noelem,9) $ set lines per page putsys(13,2) $ write printed output to unit 13 ofp oes2s,ostr2 // s,n,cardno $ putsys(linespp,9) $ reset lines

Known Error

CR 35050

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Miscellaneous - Data Transfer between Window and UNIX

Description

When an input file for MSC/NASTRAN is generated in a Microsoft Windows environment and is moved to a window on a unix computer with the drag and drop feature, it causes input errors. Each line of input has a "|" symbol at its end, symbolizing an illegal, unprintable character (carriage return) in the input,

Known Error

CR 35050 leading to many illegal input messages. Avoidance: An avoidance is to use a file transfer utility such as ftp instead. It may require some experimentation to find out if the ftp utility you use avoids inserting these illegal characters. They are carriage return symbols. MSC has had success using the ftp option in the EXCEED product. MSC/NASTRAN itself will delete these spurious carriage returns from its input files, starting with Version 70.6. If other files are transferred

Known Error

CR 35054

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Optimization/Design Sensitivity - INREL - UFM 6143 If inertia relief (PARAM,INREL,-1) is requested in SOL 200 and there are more than 12 static load cases then the run will fail with UFM 6143 in the MERGE module in subDMAP INERSEN. Avoidance: Insert the following DMAP alter in V70 or V70.5:

Description

compile inersen alter 'nld6\=' $ type parm,,i,n,nz $ nz=nld6-5 $ alter 'vn6r'(2),'' matgen ,/vn6r/4/1/nld6r//6/nz/i661/0/1 $ alter 'vn6r'(4),'' matgen ,/vn6r/4/1/nld6r//6/nz/i661/0/1 $ endalter

Known Error

CR 35066

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Optimization/Design Sensitivity - DRESP2 - UFM 315 When a DRESP2 bulk data entry is missing a continuation line an error message is issued but the message indicates that a subsequent DRESP2 is in error. The message is similar to the following:

Description

*** USER FATAL MESSAGE 315 (IFPDRV) FORMAT ERROR ON BULK DATA ENTRY DRESP2 1001 SORTED ENTRY COUNT = 584 USER INFORMATION : THE FORMAT OF DRESP2 ENTRY HAS BEEN MODIFIED IN

Known Error

CR 35066 MSC/NASTRAN VERSION 68. PLEASE REFER TO THE QUICK REFERENCE GUIDE FOR MORE INFORMATION. USER INFORMATION : PLEASE NOTE THAT THE FORMATS OF THE FOLLOWING DESIGN OPTIMIZATION ENTRIES HAVE BEEN MODIFIED IN MSC/NASTRAN VERSION 68 : DCONSTR DOPTPRM DRESP1 DRESP2 DSCREEN DTABLE DVPREL1 DVPREL2 *** USER FAT

Known Error

CR 35067

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Description

Frequency Response - PBUSH, PELAST - UFM 5423, 6719 In SOL 111, if there are frequency dependent elements, and if the a-set equals the g-set, the modal reduction of the frequency dependent matrices is not performed. In a structural analysis, this results in UFM 5423, and in an acoustic (uncoupled) analysis, the result is SFM 6719. Avoidance: Add a dummy SPC.

Known Error

CR 35096

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Iterative Solver - ITER, DEFORM - SFM 6980 (SB85RD) A job that uses the iterative solver and specifies DEFORM type loads failed with the message:

Description

*** SYSTEM FATAL MESSAGE 6980 (SB85RD) LARGEST BLOCK ROW OF THE INITIAL MATRIX ( 85606 WORDS) EXCEEDS THE SPECIFIED MAXIMUM RECORD LENGTH ( 65536 WORDS). USER ACTION: PLEASE CONTACT MSC CLIENT SUPPORT. *** SYSTEM FATAL MESSAGE 3008 (UTMCOR) MODULE = SOLVIT INSUFFICIENT CORE AVAILABLE FOR SUBROUTINE USER ACTION: INCREASE OPEN CORE BY AT LEAST 20070 WORDS PROGRAMMER INFORMATION: LOCATION KEY = M FATAL ERROR Avoidance: Increasing memory may solve the problem but it is likely that the sparse solver will need to be selected.

Known Error

CR 35117

Product

MSC / MD Nastran

Known Error

CR 35117

Corrected Version 70.7 Abstract

Acoustic Analysis - FORCE(PHASE) - Wrong Answers

Description

When magnitude/phase force output is requested for fluid elements, real/imaginary outputs are printed in the magnitude/phase format instead. Avoidance: There is no avoidance.

Known Error

CR 35121

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Optimization/Design Sensitivity - DRESP1, DRESP2 - UFM 7139 (DOPR3C) When an unreferenced DRESP1 entry of RTYPE=FREQ appears in a superelement optimization job the fatal message below may occur:

Description

*** USER FATAL MESSAGE 7139 (DOPR3C) ON DRESP2 entry ID = 10, RESP1 ID = 1001 DOES NOT REFERENCE AN EXISTING DRESP1 ENTRY. Avoidances: 1) Remove the unreferenced DRESP1 entry using RTYPE=FREQ or 2) Use RTYPE=EIGN instead of RTYPE=FREQ

Known Error

CR 35138

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Documentation/SSSALTER - prldbckla.v706 - no longer needed Buckling with preload has been included in the standard 105 solution sequence in v70.6. Therefore, the prldbcka alter is no longer needed. Avoidance: The new capability is invoked through the STATSUB Case Control command. The documentation for STATSUB in Version 70.6 follows:

Description

Format: STATSUB[(BUCKLING)]=n (PRELOAD) Examples: STATSUB=23

Known Error

CR 35138 STAT=4 STATSUB(PRELOAD)=7 Describer Meaning BUCKLING Subcase id number corresponding to static subcase of buckling or varying load (default in buckling analysis) PRELOAD Subcase id number corresponding to static subcase of preload or constant load (default in dynamic analysis) n Subcase identification number of a prior SUBCASE specified for static analysis (Integer>0) Remarks: 1. Unchanged 2. Unchanged 3. R

Known Error

CR 35139

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Inertia Relief - param,inrel,-1 - UFM 9105 If param,inrel,-1 is included in the input file for a solution sequence that does not use inertia relief (e.g., sol 103), then the job will terminate with the following error messages:

Description

^^^ USER FATAL MESSAGE 9105 (PHASE0) ^^^ A SUPORTI BULK DATA ENTRY IS NOT PRESENT FOR INERTIA RELIEF ANALYSIS (PARAM,INREL,-1). Avoidance: Remove param,inrel,-1 from the input file since it is not used in a non inertia relief run.

Known Error

CR 35141

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Description

Frequency Response/Complex Eigenvalues - PARAM,MODACC, CVISCi Wrong Answers If PARAM,MODACC,>-1 is specified in SOLs 110, 111, 146, or 200 with ANAL=MFREQ and the model contains viscous damping then wrong answers will result. Avoidance: Insert the following DMAP alter:

Known Error

CR 35141 compile gma alter 'call xADD5 K2XDD' equivx b2ydd/b2dd/-1 $ endalter

Known Error

CR 35143

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Optimization/Design Sensitivity - DSADJ - SFM 1015 (GBKMGR) The fatal message: SYSTEM FATAL MESSAGE 1015 (GBKMGR)

Description

may occur in the DSADJ module and has been attributed to an incorrect assessment of the amount of open core available. Avoidance: The message has only occurred when running with a small memory request. A possible avoidance is to increase the memory request.

Known Error

CR 35154

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Superelements - BEGIN SUPER - SFM 3007 In a superelement analysis using PARTS, if more than 12 points occupy the SAME location at the boundary in the same superelement, then the job will fail with the following messages:

Description

*** SYSTEM FATAL MESSAGE 3007 (SEP1X) ILLEGAL INPUT TO SUBROUTINE SEPBSD 0FATAL ERROR Avoidance: Do not define more than 12 points occupying the same location at the boundary for a single part superelement.

Known Error

CR 35158

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

DMAP - LCGEN - SFM 3007, Poor Message

Description

If the first input, usually CASES, to LCGEN is purged then SFM 3007 is issued. SFM 3001 should be issued instead.

Known Error

CR 35158 Avoidance: There is no avoidance.

Known Error

CR 35187

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Miscellaneous - UFM 6440 (MODGM2) If double-field entries are used to enter property ID's longer than 8 digits, then it is possible to obtain USER FATAL MESSAGE 6440 indicating that a property id is not found even though it exists in the input file. The cause of this error is the sorting routine which uses only the first 8 digits of the id. The problem will only occur if property ID's which are both 8-digit and longer than 8-digits exist in the input. Avoidance: Either keep the property ids less than 9 digits, or use all property ids greater than 8 digits in length.

Known Error

CR 35188

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Restarts - SFM 471 The database of large restart runs may be corrupted when data spills from one file to another. In the restart run the error may lead to the message:

Description

** ERROR ** UNABLE TO VALIDATE DATABASE FILE FORMAT. DATABASE MAY NOT HAVE BEEN BUILT ON A COMPATIBLE PLATFORM. BIOPNR ERROR ** TIMESTAMP/RECL VALIDATION FAILED. FILX = 30, LOGNAME = DBALL5 , NSBUF3 = 4096 FILE = /disk/tmp/test.dball TIMESTAMP OFFSET INVALID. *** SYSTEM FATAL MESSAGE 471 (DGETTS) ERROR ATTEMPTING TO OPEN THE FOLLOWING PHYSICAL FILE NAME (PFILEX= 30) : /disk/tmp/test.dball USER ACTION: 1) CHECK THE READ/WRITE PRIVILEGES GRANTED THIS FILE. 2) CHECK MAXIMUM NUMBER OF FILES THAT MAY BE OPENED SIMULTANEOUSLY. 3) CHECK THAT THIS DATABASE FILE IS COMPATIBL

Known Error

CR 35197

Product

MSC / MD Nastran

Known Error

CR 35197

Corrected Version 2001 Abstract

Documentation/Optimization - QRG, PBUSH, DVPRELi - Unexpected Results The Quick Reference Guide fails to document that when a property on a PBUSH entry is designed a negative FID number must be specified on the DVPREL1 and DVPREL2 entries. If a positive FID number is specified on a DVPREL1/2 entry, unexpected results may occur.

Description

Avoidance: Use a negative word position number from the element property table for the FID field on the DVPREL1/2 entry. The following table provides the word positions for the PBUSH entry in the element property table. EPT Section for PTYPE = "PBUSH" Word Type Item 1 I Property ID 2 through 7 R K1 through K6 8 through 13 R B1 through B6 14 R

Known Error

CR 35200

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - QRG - FSLIST Missing from QRG Version 69 and later Quick Reference Guides do not have a description for the FSLIST bulk data entry. Avoidance: See the V68 Quick Reference Guide or the Fluid-Structure Seminar Notes for the description. An abbreviated description follows: FSLIST Defines the fluid points (RINGFL entry) that lie on a free surface boundary.

Description Format: FSLIST, RHO, IDF1,IDF2,IDF3........ Field Contents RHO Mass density at the surface. Real>0.0; the default is taken from DRHO on the AXIF entry). IDFi Identification number of RINGFL entry. (Integer>0 or Character="AXIS"

Known Error

CR 35200 in first and/or last field only) Remarks: 1. This entry is allowed only if an AXIF entry is also present. 2. The order of the points must be sequential with the fluid on the right with respect to the directi

Known Error

CR 35206

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

External Superelements - PARAM,EXTOUT - Wrong Answers, UFM 5423 If external superelements are used and restarts are performed, the restart logic will insist on re-processing the external superelements and any downstream superelements whether or not any changes are made to the model. If the superelements are created using PARAM,EXTOUT,DMIGDB, this may result in incorrect answers or UFM 5423 indicating an incompatible matrix multiply.

Description

Avoidance: When restarting from a run which read in external superelements which were created using PARAM,EXTOUT,DMIGDB insert the following DMAP alter: compile extin alter 'IF.*NOKAA.*0.*THEN','' IF ( NOKAA>0 and nomatk1 ) then $ MATMOD YST,,,,,/YS,/1/1 $ else $ equivx yst/ys/-1 $ endif $ yscol>1 alter 'MATMOD YST'(2),'' paraml yst//'trai'/1/s,n,yscol $ if ( yscol>1 ) then $ MATMOD YST,,,,,/YSt1,/1/1 $ else $ equivx yst/yst1/-1 $ endif $ yscol>1

Known Error

CR 35411

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Submittal - news=yes - UFM 756 (XCSA) If an include statement is the first line of an input deck or follows immediately after a NASTRAN statement and news=yes is requested, then the job may fail with the message:

Description

USER FATAL MESSAGE 756 (XCSA) THE BEGIN CARD IS NO LONGER SUPPORTED IN THE EXECUTIVE CONTROL SECTION. USER INFORMATION: THE BEGIN STATEMENT IN THE EXECUTIVE CONTROL SECTION HAS BEEN REPLACED BY THE SUBDMAP DMAP STATEMENT. SEE USER MANUAL SECTION 5. ENDDATA *** USER FATAL MESSAGE 765 (XREAD) END-OF-FILE ENCOUNTERED ON UNIT 1. THE INPUT FILE IS INCOMPLETE. USER INFORMATION: THE FOLLOWING GUIDE LINES SHOULD BE FOLLOWED FOR PREPARATION OF AN INPUT DECK. FILE MANAGEMENT SECTION (FMS) CAN BE ENDED BY EITHER AN "ENDJOB"

Known Error

CR 35411 OR A NON-FMS CARD.

Known Error

CR 35415

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Optimization/Design Sensitivity - REPCASE, SET - SFM 3003 (DOPR3) The fatal message shown below may be issued in an optimization job if there are REPCASE subcases but no SETt case control commands (all the data recovery requests = ALL)

Description

*** SYSTEM FATAL MESSAGE 3003 (DOPR3) ATTEMPT TO READ PAST RECORD IN DATA BLOCK Avoidance: Place a set command in the case control.

Known Error

CR 35460

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Nonlinear Transient Analysis - NLTRD, PARAM,SNORM - SFM 4276 A nonlinear transient run may give a traceback similar to the following when param,snorm is used.

Description

+80 Offset 0x000001c4 in procedure getnml_ +81 Offset 0x0000003c in procedure gshnod_ +82 Offset 0x00001688 in procedure nqd4d_ +83 Offset 0x00000258 in procedure nembrd_ +84 Offset 0x00001124 in procedure nlemg_ +85 Offset 0x000004c0 in procedure nltrd_ +86 Offset 0x000001a4 in procedure xsem15_ Avoidance: Do not specify param,snorm.

Known Error

CR 35483

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Description

Performance - SGI Only, Implausible Warning Message with ff_io=no MSC/NASTRAN V70.5(r4) mistakenly omitted support for EAG FFIO in the template file. On some jobs this may lead to a slight degradation in I/O performance and hence longer run times.

Known Error

CR 35483 Avoidance: This can be corrected by updating: /bin/nast705.lcl After line 143, which currently reads: %MSC_ARCH=irix64:%%threads:% print "MP_SUGNUMTHD_VERBOSE: %thread_verbose%" the following lines can be added: %MSC_ARCH=irix64:%%ff_io=^[ya]:%%ff_io_opts:% export FF_IO_OPTS='%ff_io_opts%' %MSC_ARCH=irix64:%%ff_io=^[ya]:%%ff_io_defaults:% export FF_IO_DEFAULTS='%ff_io_defaults%' %MSC_ARCH=irix64:%%ff_io=^[ya]:% print "EAG FFIO enabled." %MSC_ARCH=irix64:%%ff_io=^[ya]:% print "FF_IO_OPTS: $FF_IO_OPTS" %MSC_ARCH=irix64:%%ff_io=^[ya]:% print "FF_I

Known Error

CR 35508

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Eigevalue Analysis - READ - UIM 4158, Massless Mechanisms Eigenvalue analysis of models with massless mechanisms may fail in the READ module with the following messages:

Description

*** USER INFORMATION MESSAGE 4158 (DFMSA) ---- STATISTICS FOR SPARSE DECOMPOSITION OF DATA BLOCK KFF FOLLOW NUMBER OF NEGATIVE TERMS ON FACTOR DIAGONAL = 5 MAXIMUM RATIO OF MATRIX DIAGONAL TO FACTOR DIAGONAL = 1.0E+15 AT ROW NUMBER 4*** SYSTEM FATAL MESSAGE 7340 (LNNHERR) process error reported by subroutine LNNP1ED see LNNP1ED abstract (ier = -729) *** SYSTEM FATAL MESSAGE 7340 (LNNHERR) process error reported by subroutine LNNDRVD see LNNDRVD abstract (ier = -729) Avoidance: Add a small amount of mass to the mechanism or remove the mechanism.

Known Error

CR 35547

Product

MSC / MD Nastran

Corrected Version 70.5.5

Known Error

CR 35547

Abstract

ESTIMATE - Will not work if there is a blank space in path

Description

If a directory in the path to the file contains a blank space (for example ('Program Files'), MSC/ESTIMATE will not be able to find the input file and will fail. Avoidance: Do not include blank spaces in directory names.

Known Error

CR 35549

Product

MSC / MD Nastran

Corrected Version 2005.1 Abstract

Superelements - SFM 3007 (SEP1X), Illegal input to subroutine SEPEXT

Description

If an EXTRN entry is not used when trying to use the new (V69+) external superelements, the run will fail and issue SYSTEM FATAL MESSAGE 3007 indicating illegal input to subroutine SEPEXT. The run will then terminate. Avoidance: Be sure to use an EXTRN entry when using the external superelements.

Known Error

CR 35551

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Description

Superelements - THRU, SPOINT, EXTRN - UFM 6739 (SEP2MP) If the THRU range is used on the EXTRN entry for a set of SPOINTs, the program will incorrectly issue UFM 6739 stating that the SPOINTs are specified with a nonzero degree of freedom Avoidance: Do not use the THRU option on the EXTRN for SPOINTs.

Known Error

CR 35562

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Description

Aeroelastic Analysis - TRIM - Wrong Answers Version 70.5 introduced the capability in SOL 144 to trim an aircraft that had more free variables than there are free degrees of freedom. The results from this Generic Control System capability will be in error unless the aerodynamic extra points (AESTAT and AESURF) specified on the TRIM bulk data entry are in ascending ID order. Avoidance: When there are redundant control surfaces, list the known trim variables on the TRIM entry in ascending ID order. The ID's are those

Known Error

CR 35562 entered on the AESTAT and AESURF bulk data entries.

Known Error

CR 35603

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Parallel Processing - Distributed Memory Parallel - Confusing Messages At submittal, confusing error messages may be issued to the terminal when running MSC/NASTRAN V70.5.3 or V70.5.4 on AIX in distributed mode. The various messages may lead you to believe the job has failed even though it hasn't. The error messages will be displayed if the IBM Parallel Environment for AIX V2.4 or later is installed.

Description

Avoidance: The messages may be ignored or they may be avoided by changing the following line in the /bin/nast705.dmp file from: %MSC_ARCH=aix:% print -u3 $host %cpu_use% %adapter_use% to %MSC_ARCH=aix:% print -u3 $host

Known Error

CR 35615

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Aeroelastic Analysis - scr=mini, multiple subcases, SOL 145 - Missing output If multiple flutter subcases are specified in a SOL 145 job and the job is run with scr=mini, then the job will only process the first subcase and ignore subsequent subcases. Avoidance: Insert the following DMAP alter:

Description

Known Error

compile super3 alter 'saverstl\=','' compile sefluttr alter 'call super3'(,1) if ( saverst='sedr' ) saverstl=true $ compile sedisp alter 1 file ol1s=ovrwrt $ endalter CR 35619

Known Error

CR 35619

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Complex Eigenvalue Analysis - Number of Desired Roots not Found

Description

Prior to MSC/NASTRAN 70.7 the Complex Lanczos eigenvalue method would require the user to specify many shifts to find many modes in a lightly damped system. Beginning in Version 70.7, an the system will automatically choose new shifts until the desired number of modes is found.

Known Error

CR 35622

Product

MSC / MD Nastran

Corrected Version 70.5.2 Abstract

DMAP - ISHELL may have Difficulties Locating the Called Program In versions prior to V70.5.2, the ISHELL module may have difficulty locating the called program file. This may result in the fatal message: ^^^ PRECLOSING FORTIO UNIT 25 ^^^ ISHELL PROCESS RETURN CODE: 1 ^^^ ISHELL FAILED WITH RETURN CODE 1

Description

Starting with V70.5.2, the search logic has been improved to search for different file extensions and thru the path correctly. Avoidance: If you are using ISHELL in a version prior to V70.5.2, use a program name containing the exact name specified in the ISHELL statement (upper-case only, maximum of 8 characters including the extension) and make sure that the program is in the current directory.

Known Error

CR 35630

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Postprocessing/Eigenvalue Analysis - PARAM,POST- Wrong Eigenvector Labels in XDB If multiple eigensolutions are requested in SOL 103 with PARAM,POST,0, then the eigenvectors will be labeled incorrectly in the xdb file.

Description

Avoidance: Use PARAM,POST,-1 or insert the following DMAP alter: compile super3 alter 'EQUIVX CASECC',''

Known Error

CR 35630 EQUIVX CASErs/CASESEP4/-1 $ endalter

Known Error

CR 35633

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Acoustic Analysis - Missing Output In solution 108, if displacements are requested for fluid grids, and accelerations are requested for structural grids, then no fluid grid pressures will be output.. Avoidance: Solution 111 works correctly.

Known Error

CR 35646

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Acoustic Analysis/Superelements - CAABSF - UFM 9101 If a fluid superelement is used, and frequency dependent acoustic absorbers (CAABSF) are correctly put in the residual with their fluid grids (in order to keep them frequency dependent), then an error message similar to the following is erroneously invoked causing the run to fail prematurely:

Description

^^^ BULK DATA AND CASE CONTROL PARTITIONING, RESTART CHECKING, AND UNDEFORMED PLOTTING IS ^^^ INITIATED FOR SUPERELEMENT 0 ^^^ USER FATAL MESSAGE 9101 (PHASE0) ^^^ FLUID ELEMENTS ARE DETECTED IN THIS SUPERELEMENT. ^^^ USER ACTION: ENSURE THAT ALL FLUID ELEMENTS ARE ASSIGNED TO SUPERELEMENT 2000 Avoidance: Insert the following DMAP alter: compile phase0 alter '9101'(,-1),'' paraml ects//'trailer'/5/s,n,trwd5 $ bits 161-176 and 65-80 type parm,,logi,n

Known Error

CR 35647

Product

MSC / MD Nastran

Corrected Version 70.7

Known Error

CR 35647

Abstract

Elements - CBEAM, GP2 - UFM 2007, Undefined Grid Point If a model contains both CBAR and CBEAM elements and the value of BIT is set to 0.0 on a CBEAM entry and p-elements are not being used, the run will fail with UFM 2007 stating that the BEAM element references an undefined GRID point.

Description

*** USER FATAL MESSAGE 2007 (GP2) ELEMENT xx REFERENCES UNDEFINED GRID POINT yyy Avoidance: Do not place a value in the BIT field of the BEAM element unless you are using p-elements.

Known Error

CR 35657

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Documentation/QRG - THERMAL - Clarification of Remark 1 The following remark should be added to THERMAL case control command description in the Quick Reference Guide. 3. In a transient heat transfer analysis the SID on the punched TEMP bulk data entries equal the time step number.

Known Error

CR 35695

Product

MSC / MD Nastran

Corrected Version GL Abstract

Restarts - Nastran fails to trap invalid dbset that have been copied. Nastran fails to trap invalid copies of DBSETs used in RESTART (or reuse) runs. The following sequence demonstrates the problem:

Description

Known Error

> nastran s31498a.dat # cold start run creates s31498a.MASTER and s31498a.DBALL > cp s31498a.MASTER s31498b.MASTER # copy s*a.MASTER to s*b.MASTER; DBALL is not copied > nastran s31498b.dat # run using s*b.MASTER; nastran finds s*a.DBALL using autoassign > nastran s31498a.dat # run using s*a.MASTER; nastran fails to recognize s*a.DBALL was modified above and is no # longer in synch with s*a.MASTER CR 35726

Known Error

CR 35726

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Elements - CBUSH - UWM 979 (XYTRAN), THE ID COULD NOT BE FOUND Trying to use XYPLOT for CBUSH postprocessing results in the following error message:

Description

*** USER WARNING MESSAGE 979 (XYTRAN) AN XY-OUTPUT REQUEST FOR POINT OR ELEMENT ID n -FORC- CURVE IS BEING PASSED OVER. THE ID COULD NOT BE FOUND IN DATA BLOCK 106

Known Error

CR 35743

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Description

Aeroelastic Analysis - IFP - UFM, TRIM Entries with no Fxed Parameters If you define a TRIM subcase in MSC/NASTRAN in which all trim parameters (aerodynamic extra points) are FREE, the resultant MSC/NASTRAN execution will fail due to an illegal TRIM Bulk Data Entry.MSC/NASTRAN considers it to be illegal to have a TRIM entry with zero PARAM/VALUE pairs. That TRIM entry would imply that all parameters were FREE, something that is not necessarily illegal, even for regular TRIM. Avoidance: Specify at least one parameter that is fixed at some value.

Known Error

CR 35745

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Elements - PBARL/PBEAML, SOLs 1-16 - UFM 1126 (GNFIST) or 2011 (TA1) PBARL and/or PBEAML entries do not work in SOL 1. They cause the following error message: in V69.0 - V70.0;

Description

*** USER FATAL MESSAGE 1126 (GNFIST) DMAP MODULE MODEPT IS ATTEMPTING TO OUTPUT DATABLOCK 201 NAME = IEPT , WHICH ALREADY EXISTS. USER ACTION: DELETE THE DATABLOCK, OR USE FILE IEPT =OVRWRT FATAL ERROR or UFM 2011 (TA1) in V70.5;

Known Error

CR 35745 *** USER FATAL MESSAGE 2011 (TA1) NO PROPERTY ENTRY FOR ELEMENT TYPE BAR *** USER FATAL MESSAGE 2011 (TA1) NO PROPERTY ENTRY FOR ELEMENT TYPE BEAM 0FATAL ERROR Avoidance: Insert the following DMAP alter in SOLs 1-16: MALTER 'IFP9 EPT','' IFP9 EPT.7/IEPTX/S,N,NOGOIFP9 $ endalter

Known Error

CR 35754

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract Description

Documentation - Missing Beam Server Documentation in NT C.O.G. The documentation for the beam server is missing from the "Configuration and Operations Guide, Windows NT Edition". Avoidance: The UNIX documentation can be used in its place.

Known Error

CR 35760

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

Transient Analysis - MPCFORCES - Inconsistent Answers In a transient analysis, the MPCFORCES may appear incorrect because they may vary when the independent and dependent degrees of freedom are reversed. This is due to the inconsistency between the way the "equilibrium" is calculated using the modified Newmark integration scheme (which is evaluated at 3 time steps-- Un+1, Un, and Un-1) and the MPCFORCE data recovery (which is evaluated at Un). Avoidance: Use a smaller time step if mpcforces are desired. The error is negligible if (delta t)**2 * acc -1 )','IF ( NLKOT>-1 )' IF ( NLKOT>-1 OR RESVEC='YES') THEN $ endalter

Known Error

CR 36076

Product

MSC / MD Nastran

Corrected Version 2004

Known Error

CR 36076

Abstract

Miscellaneous - INPUTT2 - SFM 6551 with READ ONLY file

Description

On NT computers, if the permission of a file used for INPUTT2 is "read-only", the program may fail with SYSTEM FATAL MESSAGE 6551 indicating that the end-of-file was detected incorrectly. Avoidance: Change the file permission to be full access.

Known Error

CR 36078

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Complex Eigenvalue Analysis - SCR=NO - UFM 9050 (SEKRRS) If while running a Complex Eigenvalue Analysis in MSC/NASTRAN Version 70.6 the run encounters

Description

^^^ USER FATAL MESSAGE 9050 (SEKRRS) ^^^ RUN TERMINATED DUE TO EXCESSIVE PIVOT RATIOS IN MATRIX KLL. and SCR = NO, set SCR = YES this may correct the problem.

Known Error

CR 36096

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Eigenvalue Analysis - GIV, MGIV, HOU, MHOU - UWM 4648,3034 When the tridiagonal eigensolution methods GIV, MGIV, HOU, or MHOU are selected, and the roots are closely spaced, the messages below may result: 0***USER WARNING MESSAGE 4648---- THE MODAL MASS MATRIX IS NOT POSITIVE DEFINITE. 0*** USER WARNING MESSAGE 3034, ORTHOGONALITY TEST FAILED. LARGEST TERM = 1.00E+00 ,NUMBER FAILED = 36

Description

Avoidances: An avoidance is to select the Lanczos method instead. It tests for orthogonality as a requirement for stopping the solution process. Another avoidance when using the tridiagonal methods is to stlightly perturb the system so that the repeated roots are separated. It was found by experiment with a 10 by 10 problem with 9 repeated roots in one cluster that only the first four modes had good orthogonality. If 10 stiffness terms

Known Error

CR 36104

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Optimization/Design Sensitivity - DEQATN - Infinite cpu Loop, read error If a large DEQATN entry is used, then depending on the machine, the job may terminate without any messages in the f06 or f04 files or the run may appear to be caught in an infinite loop. Depending on the machine, any of the following messages may appear in the log file. This situation can occur even if the number of non-zero characters are below the 32,000 limits.

Description

1. fmt: read unexpected character apparent state: unit -1 named last format: (I2,4X,I4) Unit -1 is a (null) formatted internal file *** Execution Terminated (115) *** 2. 1525-097 A READ statement using decimal base input found the invalid digit '' in the input file. The program will recover by assuming a zero in its place. Avoidance: Reducing the size the DEQATN entry.

Known Error

CR 36112

Product

MSC / MD Nastran

Corrected Version GL Abstract

Transient Response Analsyis - DRMS1 DMRH1 - UWM 5186, Missing Output DMAP modules DRMS1 and DRMH1 will issue the message: *** USER WARNING MESSAGE 5186. (DRMH1C) A CHANGE IN WORD 2 OF THE OFP-ID RECORDS OF DATA BLOCK 101 HAS BEEN DETECTED. PROCESSING OF THIS DATA BLOCK HAS BEEN TERMINATED.

Description

and no output will be produced when the input OUGV1 matrix contains more than 1 type of grid output request (e.g. displacements AND velocities).

Avoidance: The easiest avoidance is to only include one type of output request in the case control (e.g. DISP or VELO or ACCE). A possible DMAP avoidance would involve breaking the UG matrix into 3 separate matrices (disp, vel, acc) before running through SDR2 to make 3 separate OUGV1s.

Known Error

CR 36133

Product

MSC / MD Nastran

Corrected Version

70.7

Abstract

Optimization/Design Sensitivity - Rigid Element Sensitivity - UFM 1126 in DSVGP5 If rigid element sensitivity is requested in SOL 200 for static and frequency response analysis, then UFM 1126 is issued from module DSVGP5 in subDMAP PSLGDV for data block ENX3. Avoidance: Insert the following DMAP alter:

Description

compile pslgdv alter 1 file enx3=ovrwrt/kmmb=ovrwrt/kmntb=ovrwrt/kmnb=ovrwrt/knnb=ovrwrt/ gtkmn=ovrwrt/ym=ovrwrt/egxx=ovrwrt/egx3=ovrwrt/mmmb=ovrwrt/ mmntb=ovrwrt/mmnb=ovrwrt/mnnb=ovrwrt/gtmmn=ovrwrt/gtmmny=ovrwrt/ gtmyg=ovrwrt/gtkmny=ovrwrt/gtbmny=ovrwrt/gtbyg=ovrwrt/gtkyg=ovrwrt/ gtkyg1=ovrwrt/gtk4yg=ovrwrt/gtk4mny=ovrwrt/egx4=ovrwrt $ endalter

Known Error

CR 36136

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Optimization/Design Sensitivity - PBEAML, PBARL - Incorrect Sensitivities The sensitivities of the stress recovery locations with respect to the section dimensions are in error for the CHAN and Z section types. This error will result in incorrect stress response sensitivities.

Description

Avoidance: There is no avoidance. The magnitude of the error has been under 10% in the examples that have been seen. Thus, the designs produced using the incorrect sensitivities should be adequate.

Known Error

CR 36155

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Description

Design Sensitivity - DSAMODES, SENSITY - Poor Performance The eigenvector sensitivity capability of the dsamodes module requires the identification of the row of the eigenvector which contains the largest value. Currently this is done by a do loop in the subdamp which checks the magnitude of each term in the vector in turn. This can be very time consuming if the size of the eigenvector is large.

Known Error

CR 36155 Avoidance: Insert the following DMAP alter: compile dsamodes alter 'do while ( mode'(,-1) PARAML USET//'USET'//////'f'/S,N,NOfSET $ matgen ,/row1/4/nofset/1 $ row matrix of 1 2 3 4 .... trnsp row1/rowt $ column matrix of 1 2 3 4 .... alter 'ir\=0','ir\=0'(,5) matmod phj,,,,,/phjn/2////1. $ filter out values less than one add phjn,rowt/phjx///1 $ element-by-element multiply norm phjx/junk///s,n,irr $ find row number

Known Error

CR 36160

Product

MSC / MD Nastran

Corrected Version GL Abstract

User's Modifiable - blank common block - Possible Wrong Answers The blank common block name for the User's Modifiable has been changed for Version 70.5. If the old name common / / is used, the results may be unpredictable.

Description

Avoidance: Replace the following common block common / / with common /BLNKCM/

Known Error

CR 36215

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation/QRG - PCOMP - Failure Index Output In the MSC/NASTRAN V70.5 QUICK REFERENCE GUIDE, Remark 7 under the PCOMP bulk data description needs to be changed: from:

Description 7. ELFORCE and ELSTRESS requests must be present for all elements for which ply stress or failure index output is desired. to:

Known Error

CR 36215 7. In order to get failure index output the following must be present: a) ELSTRESS or ELSTRAIN case control commands, b) Sb, FT, and SOUTi on the PCOMP bulk data entry, c) Xt, Xc, Yt, Yc, and S on all referenced MAT8 bulk data entries if stress allowables are used, or Xt, Xc, Yt, Yc, S, and STRN=1.0 if strain allowables are used.

Known Error

CR 36230

Product

MSC / MD Nastran

Corrected Version 2001.0.1 Abstract

Description

Aeroelastic Analysis - SPLINEi, SET1, SET2 - Unexpected Answers If an input file contains both a SET1 and a SET2 Bulk Data entry with the same identification number, one or the other willl randomly be used in the spline(s) that reference that SETi identification number. There is no way to control which entry will be used and no error message is issued that indicates that one of the two inputs is being ignored. Avoidance: There is no real avoidance. You must ensure that your SET1 and SET2 entries do not have common identification numbers.

Known Error

CR 36245

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - DEFUSET - UFM 316 When DEFUSET References PA or PS Sets If a DEFUSET entry references the PA or PS sets the following fatal message will be encounterd:

Description

*** USER FATAL MESSAGE 316 (IFPDRV) ILLEGAL DATA ON BULK DATA ENTRY DEFUSET ******** SORTED ENTRY COUNT = xx

Known Error

CR 36247

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - LOADSET - Wrong Answers

Description

Multiple loadset entries may not be specified in a dynamics run. If there are loadsets in each subcase the results for the subsequent subcases use the initial loadset and are usually zero. However if the user defines the same assumed DAREA id on each of his LSEQ entries wrong results will occur for the subsequent subcase. The load is calculated from

Known Error

CR 36247 using the initial loadset. A warning or fatal message should be issued if the loadset is ignored. This problem has been fixed in the code in V2001.

Known Error

CR 36251

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract Description

Beam Library - PBEAML, PBARL - Incorrect Properties for "T1" Section PBEAML and PBARL produce incorrect I2 and J properteis for the "T1" type section. Avoidance: If possible use the "T" type section.

Known Error

CR 36257

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Nonlinear Analysis - UWM 4698 (DCMPD) Nonlinear analysis may identify degrees of freedom large factor diagonal ratios at every iteration with the UWM 4698 shown below. This may result in a large amount of output. Version 70.7 has been enhanced so that this output may be controlled by setting SYSTEM(60)=-999.

Description

USER WARNING MESSAGE 4698 (DCMPD) STATISTICS FOR DECOMPOSITION OF MATRIX KLLRH . THE FOLLOWING DEGREES OF FREEDOM HAVE FACTOR DIAGONAL RATIOS GREATER THAN 1.00000E+07 OR HAVE NEGATIVE TERMS ON THE FACTOR DIAGONAL.

Known Error

CR 36286

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Description

Loads - RFORCE - Wrong Answers In Version 69 and later systems, RFORCE will produce incorrect moment loads. Moments are produced when CONM2 entries have an offset specified. Moments are also produced for the mass associated with a PBEAM entry when an offset is specified and for the PBEAM entry when a channel cross section is specified. . Avoidance: The only avoidance is to specify an additional GRID at the offset location and use a rigid element to attach it to the main GRID.

Known Error

CR 36287

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Optimization/Design Sensitivity - MODTRAK, scr=no - SFM 3001 in DOM12 When running SOL 200 with mode tracking (MODTRAK) and scr=no, the job may terminate with the following diagnostic message in the f06 file: *** SYSTEM FATAL MESSAGE 3001 (DOM12) THE EXECUTIVE FILE -112 DOES NOT EXIST. PROGRAMMER INFORMATION: SUBROUTINE DOM11C Avoidance: Run with scr=yes or insert the following DMAP alter:

Description compile fea alter 'if ( modetrak'(2) IF ( MODETRAK>0 ) THEN $ delete /mtrak,,,, $ modtrl mtraki//nomod/nomtk $ copy mtraki/mtrak $ endIF $ MODETRAK>0 alter 'delete /mtrak'(,-1),'delete /mtrak'(,3) endalter Known Error

CR 36299

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Miscellaneous - OFP - Inefficient Processing

Description

Efficiency has been improved in the OFP module for MSC/NASTRAN Version 70.7 for jobs that request only plot output.

Known Error

CR 36350

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

FMS - INIT MASTER(NORAM) - SFM 1026 In Version 70.6, if the fms statement INIT MASTER(NORAM) is used on UNIX machines, then the job may terminate with the following error messages:

Description

*** SYSTEM FATAL MESSAGE 1026 (XIO) ATTEMPT TO ACCESS A FILE WHICH IS NOT OPENED 0********* DUMP OF XIO PARAMETERS

Known Error

CR 36350 0XIO NAME = 423 ATTEMPTED OPERATION = FILPSX FILEXX = 23 Avoidance: Remove INIT MASTER(NORAM).

Known Error

CR 36366

Product

MSC / MD Nastran

Corrected Version GL Abstract Description

SSSALTERs - mtacca.vxxx - Wrong Answers SSSALTER mtacca.vxxx assumes that the modes are mass-normalized. If your modes are not mass-normalized, wrong answers will result. Avoidance: Use the default (MASS) eigenvector normalization.

Known Error

CR 36389

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Miscellaneous - Case Control, MODES - Poor Performance If a very large value of x is requested with the modes=x case control command, then the performance will be very inefficient. An example of this situation is illutrated below:

Description

Subcase 1 modes = 20 disp = all Subcase 21 modes = 9000 disp = none Avoidance: Request a reasonable modes value.

Known Error

CR 36391

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Documentation - Superelements/CLOAD - UFM 5423 In the MSC/NASTRAN V70.5 Quick Reference Guide, remark 1 of the CLOAD case control command should read: "1. This command may only appear in the residual structure subcases (see SUPER command) and it must be specified in all of them."

Known Error

CR 36410

Product

MSC / MD Nastran

Corrected Version Abstract

Static Analysis - TEMP(INIT) - Wrong Answers for Multiple Subcases

Description

In Sol 101, if TEMP(INIT) is not defined above the subcase level, it is ignored and incorrect results occur. Contrary to the Quick Reference Guide documentation TEMP(INIT) is the recommended way for specifying the datum (reference) temperature for static analysis with temperature loads. However, TEMP(INIT) must be made above the subcase level.

Known Error

CR 36428

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Optimization/Design Sensitivity - DOPR1 - UWM 7602 The following message is correctly issued but is confusing because it states the analyis value which in this case is not greater than the maximum value allowed. The message should state the design value.

Description

*** USER WARNING MESSAGE 7602 (DOPR1I) ON PROPERTY ENTRY PBEAM WITH PID= 7610 AND FID= -9, THE PROPERTY VALUE 9.93100E+06 IS GREATER THAN THE MAXIMUM PMAX VALUE 1.00000E+07 SPECIFIED ON THE DVPREL2 761001 ENTRY.

Known Error

CR 36450

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

P-Elements - GMBC, Multiple Edge Boundary Conditions - SFM 6363 If there are multiple edge GMBC's for different coordinate directions using different methodon a p-element, the following error results:

Description

*** SYSTEM FATAL MESSAGE 6363 (EVLEDG) THE ENFORCED DISPLACEMENT VECTOR COLUMN DOES NOT EXIST FOR EDGE ID = -21 FOR COMPONENT = 3 USER ACTION: CONTACT MSC CLIENT SUPPORT. PROGRAMMER ACTION: CHECK ENFORCED DISPLACEMENT VECTOR ROUTINE (IERROR=2). Avoidance: A workaround is to use the same method for the multiple boundary conditions.

Known Error

CR 36451

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Superelements - MATMOD option 16 - Wrong Answers When using a determinate interface with an external superelement, using MATMOD option 16 may lose rigid-body modes due to numeric roundoff.

Description

Avoidance: When creating external superelements, do not use a determinate interface for the component models.

Known Error

CR 36463

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Optimization/Design Sensitivity - DVPREL1, PBUSH, PSHELL - UFM 7190 When an optimization task includes DVPRELi entries refrencing PBUSH as well as other property entries, it fails in module DOPR1 with the following error message:

Description

*** USER FATAL MESSAGE 7190 (DOPR1I) PTYPE PBUSH DEFINED ON A DVPREL1 2 ENTRY CAN NOT BE FOUND ON A PROPERTY ENTRY. USER ACTION: DELETE THE DVPREL1 ENTRY OR INCLUDE AN ADDITIONAL PROPERTY ENTRY. Avoidance: Remove DVPRELi entries which do not reference PBUSH entries.

Known Error

CR 36465

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Aeroelastic Analysis - Wrong Answers for QHHL in tpl ha145i The tpl deck ha145i fails in Version 70.6 due to an interaction between the incomplete Case Control used in this test case and the changes made to NASTRAN to support multiple aerodynamic symmetries.

Description

Under those changes, the AERO/AEROS symmetries (which are single valued for a run) are "replaced" by symmetry in Case Control. However, for upward compatibility, the AERO/AEROS symmetries are used in the absence of any Case Control. A subtle requirement of this upward compatiblity logic is that the Cases must be "aerodynamic" cases for the procedure to function. Unfortunately, HA145I doesn't have a complete Case Control, so the fact that the run is aeroelastic cannot be determined from Case. Consequently,

Known Error

CR 36465 the defaulting rules (whereby the AERO/AEROS would have provided the symmetry) were no

Known Error

CR 36528

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Description

Optimization/Design Sensitivity - DEQATN - Infinite CPU Loop If a DEQATN contains a double precision constant (e.g. 10.0D0) in a design optimization task, an infinite loop will be encountered and the job will enter the PREDOM subdmap and never complete. Version 70.7 outputs USER FATAL MESSAGE 224 to correct this problem. Avoidance: Remove the double precision constant from the DEQATN.

Known Error

CR 36530

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

TRANS - MAT5, MAT9, MAT10 - forrtl: error (65): floating invlaid The trans program may fail to convert a binary XDB file to a neutral file when MAT5, MAT9, or MAT10 entries are present in the MSC/NASTRAN input file. This error has only been duplicated on DEC ALPHAs running UNIX thus far. The error message from trans is: forrtl: error (65): floating invlaid.

Description

Avoidance: Set PARAM,GEOMU,0 which eliminates all of the undeformed geometry or edit the PHASE0 subdmap DBC statement to eliminate the writing of the MPT table.

Known Error

CR 36547

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Superelements - Limit of the number of superelements - SFM 4276, EC 1044

Description

Models that contain more than 100 superelements may fail with SYSTEM FATAL MESSAGE 4276, ERROR CODE 1044 caused by an integer overflow in routine GETOFF.

Known Error

CR 36563

Known Error

CR 36563

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Miscellaneous - SGI, OS level 6.5 - Receiving signal number 10: Bus error On the SGI when running OS level 6.5, if the scratch disk is full, then the job may fail with the following unclear messages in the log file:

Description

Receiving signal number 10: Bus error Job aborting.. Avoidance: Allocate more space with the scratch disk..

Known Error

CR 36569

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Description

Miscellaneous - SUBCOM,SUBSEQ - Missing Error Messages, Unexpected Answers The number of coefficients for SUBSEQ are limited to 200, which is documented in the QRG. However, if more than 200 coefficients are used--in the case of combining more than 200 subcases--only the first 200 coefficients are used without any warning or fatal messages. Avoidance: If more than 200 coefficients are needed, create a separate subcase

Known Error

CR 36589

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Performance - MCE1, MPC, RBE - Poor Performance When there are a large number of m-set dofs, the mce1 module may exhibit poor performance. In cases seen to date, the decomp portion of mce1 finishes in a reasonable time, but the next portion, which happens to be an fbs with many right-hand sides, ran for hours without completion.

Description

This condition can be detected by looking at the run time for the decomp operation. If the fbs takes more than 10 times this value, the avoidance below may be worth considering. Use the mce1.v706 subdmap from MSC's web site for sssalters. It has been verified that it works correctly for Version 70.5 as well. On the model in question, it reduced mce1 times from over 15 hours to minutes.

Known Error

CR 36611

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Optimization/Design Sensitivity - BNDGRID, DVGRID, MODTRK - UFM 1126 in GP4 If mode tracking is requested with BNDGRID and DVGRID entries present, then the run will fail with the message:

Description

*** USER FATAL MESSAGE 1126 (GNFIST) DMAP MODULE GP4 IS ATTEMPTING TO OUTPUT DATABLOCK 203 NAME = USET0 , WHICH ALREADY EXISTS. USER ACTION: DELETE THE DATABLOCK, OR USE FILE USET0=OVRWRT Avoidance: Insert the following alter: compile desopt alter 'lcgen '(,-3),'' if ( ambs or gmbs ) then $ endalter

Known Error

CR 36617

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract Description

Matrix - SOLVE - Possible Wrong Answers with Low Memory If insufficient memory is available for the SOLVE module with SPARSE, then the results may be incorrect. Avoidance: Increase memory.

Known Error

CR 36628

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Description

Heat Transfer Analysis - RADSET - Unnecessary Calculation of View Factors According to the MSC/NASTRAN Quick Reference Guide, the RADSET entry "Specifies which radiation cavities are to be included for radiation enclosure analysis." However, in a multiple radiation enclosure model, if an enclosure is NOT referenced on the RADSET entry, the view factors are still calculated.

Avoidance: There is no avoidance. Known Error

CR 36630

Known Error

CR 36630

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

DBC - Changing tstep or freq between subcases causes failure in dbc If tstep or freq is changed between subcases and param,post,0 is specified to create a dbc database, then dbc will not complete and the following messages will be issued to the f06 file:

Description

*** SYSTEM WARNING MESSAGE 6065 (DBC) *** DBCMSG ERROR MESSAGE 44 FROM SUBROUTINE DBCAOL OUTPUT LIST DOES NOT MATCH EXISTING IN THE DATABASE, MERGE/RESTART OPERATION IMPOSSIBLE. *** SYSTEM WARNING MESSAGE 6066 (DBC) *** DBCMSG ERROR MESSAGE 34 FROM SUBROUTINE DBC THE DBC MODULE HAS BEEN TERMINATED BECAUSE OF THE ABOVE FATAL DBC ERROR. USER INFORMATION: SUBSEQUENT DBC CALLS WILL NOT BE EXECUTED, AND THE DATABASE CONVERSION IS INCOMPLETE. Avoidance: The only avoidance is to execute the subcases in different runs.

Known Error

CR 36632

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Grid Point Stress - PARAM,CURV - Floating point overflow If PARAM,CURV,1 is specified then the run may fail in the CURV module with the following traceback:

Description

Trap encountered: SIGTRAP - Trace trap FP overflow Traceback: Offset 0x00000240 in procedure pstr2s_ Offset 0x00001bd4 in procedure curv3_ Offset 0x00000198 in procedure curv_ Offset 0x000000e4 in procedure xsem14_ Offset 0x00000984 in procedure mainal Avoidance: The input that demonstrated the error contained a STRESS=set id. The error was avoided when this request was changed to STRESS=ALL.

Known Error

CR 36636

Known Error

CR 36636

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Heat Transfer - VIEW, RADSET - UWM 6427, UIM 4534, UWM 6137 (UDSNRD) If an initial run is used to generate a radiation matrix punch file and a subsequent run inputs the punch file and defines a RADSET entry that attempts re-calculate the view factor for some but not all of the cavities, then the job will fail with the following messages:

Description

*** USER WARNING MESSAGE 6427 (VIEWD) VIEW FACTORS WILL NOT BE COMPUTED FOR RADIATION CAVITY ID= 85 BECAUSE A RADIATION MATRIX IS ALREADY DEFINED. USER INFORMATION: THE RADIATION MATRIX IS DEFINED ON RADLST OR RADMTX BULK DATA ENTRIES. *** USER INFORMATION MESSAGE 4534 (RMG2) 2 ELEMENTS HAVE A TOTAL VIEW FACTOR (FA/A) LESS THAN 0.99, ENERGY MAY BE LOST TO SPACE. *** USER WARNING MESSAGE 6137 (UDSNRD) INPUT MATRIX IS RANK DEFICIENT, RANK = 10 IERROR USER ACTION: CHECK

Known Error

CR 36645

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Rigid Elements - RBE3, GP4 - UFM 6490 When an extremely large number of RBE3 elements is used, the job may fail indicating an RBE3 input error:

Description

*** USER FATAL MESSAGE 6490 (WRGMTD) FATAL ERRORS HAVE OCCURRED WHILE PROCESSING MPC AND RIGID ELEMENT ENTRIES. PROGRAMMER INFORMATION: SIL NUMBER ******** DOES NOT EXIST IN THE DEPENDENT SIL TABLE. Other symptoms are that run times may increase greatly if the number of RBE3 elements increases. This effect begins to be noticeable at about 10,000 RBE3 elements, and becomes the dominant source of cost in runs where there are hundreds of thousands of RBE3 elements. The RBE3 code was revised in V70.7 to provide increased efficiency. The

Known Error

CR 36645 original code was made with the assumption that no model would have over 100 RBE3 elements. More modern general software tools for

Known Error

CR 36646

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Random Analysis - CBUSH - SWM 3002, UWM 979 PSDF force plots fail for BUSH elements, but RESPONSE plots work. That is: XYPLOT ELFORCE RESPONSE.... (works) XYPLOT ELFORCE PSDF...(fails with the message below)

Description

*** SYSTEM WARNING MESSAGE 3002 (RANDOM) EOF ENCOUNTERED WHILE READING DATA BLOCK OES2 (FILE 107) IN SUBROUTINE RAND2 Avoidance: There is no avoidance.

Known Error

CR 36665

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Description

Aeroelastic Analysis - PFAERO - Infinite Loop PFAERO If the user attempts to run an aeroelastic solution sequence (SOL 144, 145 or 146 or SOL 200 with aeroelastic analyses) without any aerodynamic data, an infinite loop will occur in the PFAERO subdmap. This is caused by a failure to trap the absence of the requisite aerodynamic data. Subsequently, the PFAERO subdmap (responding to data reuse logic) will endlessly attempt to create the aerodynamic model. Avoidance: You must have at least one aeroelasticity-related bulk data entry to avoid the infinite loop and trigger the "missing data" error traps.

Known Error

CR 36678

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Eigenvalue Analysis - EIGR, EIGRL - SFM 7340 The Lanczos method of eigenvalue extraction may give nonstandard error messages. For example a run may terminate with the following messages.

Description *** SYSTEM FATAL MESSAGE 7340 (LNNHERR) process error reported by subroutine LNNP2CD

Known Error

CR 36678 see LNNP2CD abstract (ier = -725) *** SYSTEM FATAL MESSAGE 7340 (LNNHERR) warning reported by subroutine LNNDRVD see LNNDRVD abstract (ier = 725) Avoidance: The LNNDRVD or LNNDRVS messages meanings are given below: ier error condition. -723 insufficient workspace revealed during lanczos iteration -724 failure of tridiagonal ql iteration to converge -725 number of eigenvalues computed exceeds internal storage limitations -726 i/o error with lanczos vector file -727 failure of bidiagonal ql iteration to con

Known Error

CR 36682

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract Description

Miscellaneous - Requesting Huge mem may yield Wrong Answers Reguesting more than 1200mb of memory on an RS6000 system may result in wrong answers or a fatal message.

Known Error

CR 36685

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Inertia Relief - INREL, SUPORT1 - SFM 3007 in UPARTN If there are multiple subcases with SUPORT1 command in some, but not all, subcases and PARAM,INREL,-1 is specified in the Bulk Data then the run will terminate with: *** SYSTEM FATAL MESSAGE 3007 (UPARTN) ILLEGAL INPUT TO SUBROUTINE PARTN

Description Avoidance: Insert the following DMAP alter: compile statrs alter 'if ( norset','' if ( norset0 ) then $ endalter Known Error

CR 36701

Product

MSC / MD Nastran

Corrected Version 2001

Known Error

CR 36701

Abstract

Dynamic Analysis - DAREA - Unexpected Answers If on the DAREA entry the coordinate system is specified as "0" for a grid point it will be interpreted as "1". For example: $ pi ci DAREA 410 3 0 1

Description

is interpeted by the program as DAREA 410 3 1 1 This may cause unexpected answers. Avoidance: Specify the desired degree of freedom.

Known Error

CR 36709

Product

MSC / MD Nastran

Corrected Version 2005.1 Abstract

Optimization/Design Sensitivity - DSVG1D - UFM 5172 When Material has no Density If a designed property (DESVAR/DVPREL1) references a material with zero density, then the job will fail with the following messages:

Description

*** USER FATAL MESSAGE 5172 (DSVG1D) THE VARIATIONAL ELEMENT ID IN MDICTDSF INCONSISTENT WITH THE VARIATIONAL ELEMENT ID IN DSPT1, MODULE DSVG1 IS TERMINATED. *** SYSTEM FATAL MESSAGE 3001 (DSVG1) THE INPUT DATA BLOCK NAMED MDICTDSF AT POSITION 1 DOES NOT EXIST. Avoidance: Specify a non-zero density on the material entry.

Known Error

CR 36727

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Description

Dynamic Analysis w/Differential Stiffness - SUPORTi, STATSUB, scr=yes UFM 4407 If differential stiffness is requested in dynamic analyis, supported degreesof-freedom are specified (see the SUPORT or SUPORT1 entries), and the job is run with scr=yes, then the mass matrix will not be reduced to the supported degreesof-freedom and UFM 4407 will be issued.

Known Error

CR 36727 Avoidance: Run with scr=no or insert the following DMAP alter: compile phase1dr alter 'or kdiff','' if ( true ) then $ endalter

Known Error

CR 36730

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Superelements - SEBULK, SECONCT - UFM 6794 When using part superelement, only a single boundary point is allowed at a particular boundary location (within a specified tolerance), this is design intent. However, it has been observed in a model that the job terminates with the following messages:

Description

*** USER FATAL MESSAGE 6794 (SEPSEB) DUPLICATE BOUNDARY POINTS DETECTED IN UPSTREAM SUPERELEMENT 1 WHILE SEARCHING 0 AT GRID 7001. LIST FOLLOWS: 13403 49682 even though the points identified do not appear to be at the same location within the tolerance. The exact cause of this error is not known at this point. Avoidance: Use the SEEXCLD command to remove all but a single boundary point at each PART.

Known Error

CR 36737

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Optimization/Design Sensitivity - PARAM SOFTEXIT YES, SDR1 - UFM 4574 If PARAM,SOFTEXIT,YES is specified with static or frequency response analysis in SOL 200, then the run will fail with UFM 4574 and SFM 3001 in module SDR1 and subDMAP SEDISP on the final data recovery.

Description

Avoidance: Insert the following DMAP alter: compile desopt alter 'dbdelete','' endalter

Known Error

CR 36741

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Response Spectrum Analysis - RSPEC - SFE 4276 EC 777 If a response spectrum analysis is performed in Version 70.5 on HP computers, then the job may fail with the following message and traceback in the RSPEC module:

Description

Process traceback ... ( 0) 0x00093e90 sysrcv + 0x2a0 [/nast2/msc705t2/hpux/analysis] ( 1) 0x01126d78 _sigreturn [/nast2/msc705t2/hpux/analysis] ( 2) 0x004935e8 rspcod_ + 0x740 [/nast2/msc705t2/hpux/analysis] ( 3) 0x00199024 rspec_ + 0xbc [/nast2/msc705t2/hpux/analysis] ( 4) 0x00098d44 xsem14_ + 0x2fc [/nast2/msc705t2/hpux/analysis] ( 5) 0x0008fbc8 mainal_ + 0x9b0 [/nast2/msc705t2/hpux/analysis] real 19.5 Avoidance: The only avoidances are to run Version 70 or generate the curves on another computer.

Known Error

CR 36752

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Miscellaneous - MSCACT - UFM (mscact) Unknown keyword The MSCACT utility incorrectly flags the keyword assignment "summary=jid" as an error and outputs the message shown below. However, "summary=job" is accepted and generates the requested functionality. USER FATAL MESSAGE (mscact) unknown keyword "summary=jid". Avoidance:

Description 1) Use "summary=job" instead of "summary=jid".

2) Alternatively, the error can be corrected by changing line 1180 of /msc705/util/mscact.c from else if( !strncmp( "job", q, lq ) ) to else if( !strncmp( "jid", q, lq ) )

Known Error

CR 36752 Once the change is made, rebuild MSCACT as described in the "Configuration and Operations Guide".

Known Error

CR 36764

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Acoustic Analysis - FORCE(PHASE), Velocities and Pressure levels - Wrong Answers

Description

The acoustic output titled "COMPLEX ACCELERATIONS VELOCITIES AND PRESSURE LEVELS" prints an incorrect format for the element ID when the MAGNITUDE/PHASE option is requested. The incorrect format is that the "PRESSURE(DB)" column is truncated and the phase values are misaligned. Here is an example of the incorrect MAGNITUDE/PHASE output: (PEAK ) COMPLEXACCELERATIONSVELOCIT IESANDPRESSURELEVELS (MAGNITUDE/PHASE) ELE-ID EL-TYPE X-ACCELERATION Y-ACCELERATION Z-ACCELERATION X-VELOCITY Y-VELOCITY Z-VELOCITY PRESSURE (DB) 1.4994E-43 HEXPR 1.364242E-11 -2.376055E-10

Known Error

CR 36776

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Optimization/Design Sensitivity - PBAL, DLINK, DOM9 - UFM 6499 (DOM9D) An optimization job which designs PBARL dimensions with DLINK entries fails in DOM9 with the following message:

Description

THE GRADIENT OF CONSTRAINT NUMBER NNNNN IS ZERO CONSTRAINT IS REMOVED FROM THE ACTIVE SET ** THIS IS A VIOLATED CONSTRAINT ** A FATAL ERROR WILL BE GENERATED

**** ONE OR MORE VIOLATED CONSTRAINTS HAS A ZERO GRADIENT **** NO PROGRESS IS POSSIBLE OPTIMIZATION TERMINATED

Known Error

CR 36776 *** USER FATAL MESSAGE 6499 (DOM9D) THE DOT OPTIMIZATION ALGORITHM HAS ENCOUNTERED AN ERROR THAT MAKES FURTHER PROGRESS IMPOSSIBLE. SEE MESSAGES ABOVE. Avoidance: There is no avoidance.

Known Error

CR 36777

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Optimization/Design Sensitivity - ANALYISIS=MODES and MFREQ - SFM 3001 in DSAH If a model has fluid-structure interaction in SOL 200 and both ANALYSIS=MODES and ANALYSIS=MFREQ are requested, the run may fail with SFM 3001, stating that data block PHG does not exist.

Description

Avoidance: The following alter will avoid the FATAL error, but has not been confirmed to give correct answers. compile fea alter 'IF.*DOSUPER3 AND NOT.*FSCOUP','' IF ( DOSUPER3 ) THEN $

Known Error

CR 36780

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Submittal - vers= - Does not get right version

Description

If a different version than the latest installed (or latest known by the invoked nastran command if under the form nastxxx where xxx is a version number) is requested, the rc files of the requested version are picked up, but not the executable and SSS.

Known Error

CR 36790

Product

MSC / MD Nastran

Corrected Version GL Abstract Description

Radiation Heat Tranfer Analysis - VIEW, UDSFA - UFM 6136, estimate=mem, unsymmetric decomp MEM=estimate did not yield the correct estimate for a large heat trasnfer radiation problem. The job subsequenty Failed with the message:

Known Error

CR 36790 *** USER FATAL MESSAGE 6136 (UDSFA) INSUFFICIENT CORE FOR NUMERIC PHASE OF SPARSE DECOMPOSITION. USER ACTION: INCREASE CORE BY 5217107 WORDS 0FATAL ERROR Avoidance: Use the following dmap alter to run the symmetric decomp instead of the unsymmetric decomp sol 153 diag 8 compile nlstatic list noref alter 'IF ( DCMPKLLT ) DCMP' (1,-1)$ modtrl kllrh////6/$ cend Heat transfer problem is all symmetirc problem and thus using symmetric decomp is a lot faster.The only exception is when there is fluid elements in the problem such as CONVM or when when the user imported the radiationmatrix from other software that has input an unsymmetric radiation exchange matrix (RADLST and RADMTX with MTXTYP =3 These are the unsymmetric physics applications anyway. As for the N4W avoidance:(there is no dmap available) Therefore the user can use: NASTRAN system(209)=0 in the executive section to force the unsymmetric solver to run UDCOMP which will require less memory or Increase mem=20MW in the NASTRAN submittal command

Known Error

CR 36792

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Aerodynamic Analysis - PARAM,OPGTKG,1 - Missing output PARAM,OPGTKG,1 requests a printout of the aerodynamic splining matrices. The capability was inadvertently deleted from Version 70.6. Avoidance: Insert the following DMAP alter:

Description

compile phase1a alter 'np\=seid','' equivx uset0/aeusets/-1 $ equivx bgpdts/aebgpdts/-1 $ dbdict datablk=(aebgpdts,aeusets) select=(name,size, modltype,aeconfig,symxy,symxz) qualcurr $ dbview bgpdtf=aebgpdts where (modltype='aerostrc' or modltype='structur' ) $

Known Error

CR 36792 dbview usetff=aeusets where (modltype='aerostrc' or modltype='structur' ) $ IF ( OPGTKG>=0 ) then $ MATGPR bgpdtf,usetff,,GPJK//'K'/'G' $ MATGPR bgpdtf,usetff,,GDJK//'K'/'G' $ endIF $ OPGTKG>=0 endalter

Known Error

CR 36815

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Composites - TEMPP3 - Wrong Answers The TEMPP3 thermal loading bulk data entry is obsolete and is no longer supported. The TEMPP3 entry may give wrong answers for composites with inplane or normal thermal gradients. Avoidance: Use the TEMPP1 bulk data entry instead which works correctly in all cases and includes the same features as the TEMPP3.

Known Error

CR 36821

Product

MSC / MD Nastran

Corrected Version Abstract

Optimization/Design Sensitivity - RHO - Incorrect Material Sensitivities The design sensitivities with respect to the material densities of transient response analysis that has a steady state response may be incorrect.

Description Avoidance: Do not specify the material density as a response for a steady state analysis since the response is not affected by the density. Known Error

CR 36823

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Nonlinear Transient Analysis - OTIME, SDR1 - BIOMSG: ERROR 211 in BLDPK In nonlinear transient analyis, if the value of an output time on an OTIME= request exceeds the time value of the final time step, the job will fail in the SDR1 module with the message:

Description

BIOMSG: ERROR 211 HAS OCCURRED IN ROUTINE BLDPK , FILE INDEX (FILEX) =0 STATUS = 0 the same job runs with fewer time step intervals for output (NO) on the

Known Error

CR 36823 TSTEPNL card or with fewer OTIME requests in the case control. Avoidance: Do not use the OTIME entry in nonlinear transient analysis. The Quick Reference Guide does not indicate that OTIME is supported for nonlinear transient solutions.

Known Error

CR 36836

Product

MSC / MD Nastran

Corrected Version GL Abstract

FMS - INIT - UFM 1257 If a large value is assigned to a DBSET member, e.g., init scratch logical(scratch(50gb)) then the job may fail with the following unclear messages:

Description

*** USER FATAL MESSAGE 1257 (DBMAP) THE MAX-SIZE SPECIFIED ON THE INIT FMS STATEMENT OR SMEM VALUE IN THE RC FILE OR SMEM KEYWORD IN THE COMMAND PROCEDURE FOR THE MEMFILE OF DBSET SCRATCH IS 100 BLOCKS AND IS LESS THAN THE RECOMMENDED MINIMUM OF 110 BLOCKS. USER ACTION: SPECIFY A MAX-SIZE OR SMEM VALUE AT OR ABOVE THE RECOMMENDED VALUE. Avoidance: Either increase the buffsize or decrease the dbset value

Known Error

CR 36842

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Superelements - PARAM,SESEF - UFM 5423 If the fraction of total strain energy (PARAM,SESEF) is requested and external superelements exist, the job will fails with USER FATAL MESSAGE 5423 ATTEMPT TO MULTIPLY INCOMPATIBLE MATRICES

Description

Avoidance: Include the following alter: compile postreig, list alter 'MPYAD.*KAA,PHILS','' type parm,,i,n,temp

Known Error

CR 36842 dbview kaanew=kaa, where(seid=temp and wildcard) temp=seid $ paraml kaanew//'trailer'/1/s,n,noaset $ MPYAD KAAnew,PHILS,/FA $

Known Error

CR 36870

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Nonlinear Static Analyis - MPCFORCE, SE, INTOUT - SFM 5423 (DMPYAD) If mpcforce output is requested in a nonlinear analysis, and the model contains superelements and intermediate output is requested, then the job will fail with the following messages:

Description

*** USER INFORMATION MESSAGE 7321 (SEDRDR) DATA RECOVERY FOR SUPERELEMENT 20 IS NOW INITIATED. *** SYSTEM FATAL MESSAGE 5423 (DMPYAD) ATTEMPT TO MULTIPLY INCOMPATIBLE MATRICES COLS ROWS FORM TYPE NZWD DENS TRAILER FOR KMG IS 101108522 1310 2 2 12 3 TRAILER FOR UGJ IS 102 1108522 2 2179608 8275 TRAILER FOR PM IS 103 5 1310 2200 TRANSPO

Known Error

CR 36930

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Miscellaneous - ECHOON, ECHOOFF - Doesn't Always Work Correctly ECHOON and ECHOOFF entries may be used in the Executive, Case Control, or Bulk Data but there are limitations. ECHOOFF must not be the first entry in the Executive Control section else it will be ignored. ECHOOFF does not handle continuation entries (for example SET commands) in the Case Control correctly. If after and ECHOOF command has been placed in the Bulk Data, PARAM entries are the only entries that follow the ECHOON command, they will not printed in the unsorted output.

Known Error

CR 36943

Product

MSC / MD Nastran

Corrected Version 70.7

Known Error

CR 36943

Abstract

Aeroelastic Analyisis - GUST - Missing Output for Gust Analysis

Description

In SOL 146, the gust loads are computed inside the GUST module and then transformed to generalized coordinates. Only the generalized loads are output. This makes it impossible for clients to manipulate these loads in any meaningful way.

Avoidance: There is no simple avoidance. Known Error

CR 36949

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

DMAP - GPFDR - Extra Output

Description

The GPFDR module with the third parameter xflag=1 (the cross strain energy output) gives extra output for the first subcase. There should be no results output for the first subcase.

Known Error

CR 36978

Product

MSC / MD Nastran

Corrected Version 70.6 Abstract

Optimization/Aeroelasticity - DMI, W2GJ - Downwash Matrices not Kept In SOL 200 with static aeroelasticity, user input downwash matrices (W2GJ) are not kept after the first cycle. Avoidance: Apply the following dmap alter in V70 and V70.5:

Description

COMPILE PFAERO ALTER 'dmiin' CALL DBSTORE W2GJ,,,,//0/1/'DBALL'/0 $ $ COMPILE FEA ALTER 'fea' $ TYPE PARM,,I,Y,IFOUND $ ALTER 'pfaero' IF ( DESCYCLE >1 ) CALL DBFETCH /W2GJ,,,,/0/1/0/0/S,IFOUND $ $

Known Error

CR 36997

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Optimization/Design Sensitivity - Premature Termination - UIM 6464

Description

An optimization job starting from a feasible region may terminate for a

Known Error

CR 36997 hard convergence after the first design cycle without showing any improvement in either objective or constraint and showing any changes in the design variables. Here is the termination message: *** USER INFORMATION MESSAGE 6464 (DOM12E) RUN TERMINATED DUE TO HARD CONVERGENCE TO AN OPTIMUM AT CYCLE NUMBER = 1. Avoidance: None.

Known Error

CR 36998

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

SSSALTER - nlgyroa.v706 - Gyroscopic Effects Ignored The version 70.6 nlgyroa.v706 sssalter does not include the gyroscopic effect. Avoidance: Replace nlgyroa.v706 with the following alter. A copy of the revised alter is also available on the MSC web site.

Description

$ $ THIS ALTER IS CONFIDENTIAL AND A TRADE SECRET OF THE $ MACNEAL-SCHWENDLER CORP. THE RECEIPT OR POSSESSION OF $ THIS ALTER DOES NOT CONVEY ANY RIGHTS TO REPRODUCE OR $ DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE, OR SELL $ ANYTHING HEREIN, IN WHOLE OR IN PART, WITHOUT THE $ SPECIFIC WRITTEN CONSENT OF THE MACNEAL-SCHWENDLER CORPORATION. $ echooff $ $ $ nlgyroa.v706 - updated 8-13-99 $ $ updated July 7, 1998 - tlr $ $ added PARAM,RFORCE,i - set i to the RFORCE to be used by this alter $

Known Error

CR 37010

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Optimization/Design Sensitivity - DRESP1 - SFM 4276, EC 31

Known Error

CR 37010 When an optimization deck includes a DRESP2 entry which references the same DRESP1 ID more than once, the following system fatal message is issued from module DOM9: BIOMSG: ERROR 31 HAS OCCURRED IN ROUTINE GETSTR , FILE INDEX (FILEX) =0

Description STATUS = 0 followed by: 0*** SYSTEM FATAL ERROR 4276.GETSTR ERROR CODE 31 PID= 0 Avoidance: Do not duplicate the same DRESP1 ID on a DRESP2 entry. Known Error

CR 37027

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Aeroelastic Analysis - RESTART - SFM 3001 for QHHA or Inefficient Restart A read-only restart in aeroelastic solution 145 will unnecessarily recompute and decompose the AJJT for a list of existing Mach numbers and reduced frequency even though the list is a subset of the original list. Another symptom is SFM 3001 for QHHA.

Description

Avoidance: If the original MKAERO1 entry is re-entered as it was input on the initial run, then the AMG and DECOMP modules in the PFAERO subDMAP will not be re-run.

Known Error

CR 37031

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Aeroelastic Analysis - AESYMXZ, AESYMXY, AECONFIG, IFP - UFM 603

Description

Case control commands are free field input and should allow users to add comments at the end of the lines so long as a dollar sign precedes the comment. The new Version 70.6 aeroelastic analysis case control commands do not allow comments to be specified on the same line as the command. The simple input file below fails in IFP due to the comments onthe AE* case control commands.

Known Error

CR 37031 sol 144 cend aesymxz=symmetric $ this is a comment on the aesymxy line aesymxy=asymmetric $ this is a comment on the aesymxy line aeconfig=csr $ this is a comment on the aeconfig line spc = 1 $ this is a comment on the SPC line begin bulk param,checkout,yes enddata

Known Error

CR 37032

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Eigenvalue Analysis - PARAM,RESVEC - Possible Wrong Answers When residual vector is requested, it has been observed on some models that the additional augmented eigenvalue is lower than the highest calculated mode. This has been observed on a very small problem and also on problems using virtual mass. Avoidance: Insert the following DMAP alter:

Description

compile resvec alter 'matmod oxf','' type parm,,rs,y,resvoxf=.001 $ matmod oxf,,,,,/ox5,/2////resvoxf $ filter again alter 'append=','' append=(noox50 ) CALL xSEDRDR, DUD,EMAP,CASEXX,SLT,ETT,MAPS,bgpdts,USET, GOAT,GOAQ,GM,CASEs,casem/ DUG/ RSONLY/'DYNAMICS'/false $ IF ( NODVD>0 ) CALL xSEDRDR, DVD,EMAP,CASEXX,SLT,ETT,MAPS,bgpdts,U CR 37132

Known Error

CR 37132

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

SSSALTERs - sedampa doesn't supposrt r-set and c-set If R- or C-set dof exist in a superelement and the sssalter sedampa is used, the associated superelement will not have modal damping applied. The alter is intended to terminate the run with a message stating that C- and R-set dof are not supported by the alter. Avoidance: Do not use R- or C-set dof with the alter. The alter has been replaced by a standard feature, which does allow R- or C-set dof to exist in Version 70.7.

Description

To correct the alter, replace paraml uset//'uset'////s,n,nousetxx//'R'/s,n,norset/ 'C'/s,n,nocset $ with paraml uset0//'uset'////s,n,nousetxx//'R'/s,n,norset/ 'C'/s,n,nocset $

Known Error

CR 37146

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Aeroelastic Analysis - RESTART, GUST - SFM 5423, Incompatible Matrices

Description

If an aerelastic gust analysis attempts to change the number of retained modes in a restart, then "SYSTEM FATAL MESSAGE 5423" is issued indicating an "ATTEMPT TO ADD INCOMPATIBLE MATRICES (SADD5)" Avoidance: Perform a cold start.

Known Error

CR 37151

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation/QRG - Plot Command AXES is miss typed as AXIS

Description

In case control section of Quick Reference Guide the Plot command AXES page header and format spell it as AXIS which is incorrect.

Known Error

CR 37152

Product

MSC / MD Nastran

Corrected Version 70.7

Known Error

CR 37152

Abstract

Optimization/Design Sensitivity - MODTRK - SFM 3001

Description

"SYSTEM FATAL MESSAGE 3001" occurs in the MODTRK module when all three of the following are present: 1. shape design variables, 2. at least one subcase with mode tracking 3. and at least one subcase with ANALYSIS=STATICS Avoidance: Place the MODTRAK request above the subcase level

Known Error

CR 37169

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation/QRG - ADAPT - Typographical Error The Quick Reference Guide description of the ADAPT entry contains the typographical error:

Description

TY=PEUNIP, SIGT=OL22 it should be TYPE=UNIP, SIGTOL=22

Known Error

CR 37173

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Optimization/Design Sensitivity - PARAM,SOFTEXIT - Incomplete Design History In SOL 200, if PARAM SOFTEXIT YES is used and soft convergence is achieved, the DESIGN CYCLE HISTORY does not include the results from the final exact analysis.

Description

Avoidance: The information that should be in the DESIGN CYCLE HISTORY can be obtained using the P1 and P2 parameters on the DOPTPRM entry.

Known Error

CR 37178

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Miscellaneous - Missing UFM 315 - Unexpected Answers

Description

If a negative sign is the only character in a field of a bulk data entry

Known Error

CR 37178 it may be ignored. This may lead to unexpected answers. For example if the negative sign was intended for the value in the following field as in the following entry: CBAR 70101 51001 464 1322 0. 0. 1.0 ++000363 ++000363 - .238 - .238 +000364 Avoidance: Specify "ECHO=PUNCH" in the Case Control and perform a search (grep) on negative signs followed by blanks ("- ").

Known Error

CR 37190

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Optimization/Design Sensitivity - PBARL - Wrong Answers Use of PBARL with "T" section in an optimization task may cause an infeasible result with Version 70.5 or earlier release of MSC.Nastran.

Description

Avoidance: 1. Use equivalent PBAR with DVPREL2 equations defining the PBAR properties. 2. Use a new version such as v70.7.

Known Error

CR 37195

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Optimization/Design Sensitivities - Rigid Elements - Incorrect Sensitivities When a shape optimization job has locations of rigid elements being designed it may result in incorrect sensitivities or may have difficulty converging. This may lead to excessive time in the DSVGP5 module.

Description Avoidance: There is no avoidance. Version 70.7 corrects this error and shows a dramatic improvement in performance of the DSVGP5 module for some problems. Known Error

CR 37222

Known Error

CR 37222

Product

MSC / MD Nastran

Corrected Version Abstract

Optimization/Design Sensitivity - RESTART - Inefficient Processing Restarts into SOL 200 will not be efficient if the design model is not included in the cold start run.

Description

Avoidance: 1. Include the design model in the cold start run or 2. Insert the following alter in the cold start run: compile prtsum alter 1 DBEQUIV WHERE (DESITER=0 and WILDCARD) , CONVERT (DESITER=1), OVRWRT $ endalter

Known Error

CR 37224

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Optimization/Design Sensitivity - PCOMP, DSAD - SFM 4276, Poor Message

Description

In solution 200, when using the cfailure criteria force item code 7 (interlaminar stress), NASTRAN will either fail in the DSAD module with system fatal 4276 or give wrong answers if the code is specified for the last lamina (ply). This fatal occurs because there are no interlaminar stresses for the last lamina since interlaminar stresses are between laminae. Also, using the cfailure criteria as force item code 8 (max of FP and FB) will fail unless the lamina (ply) number specified on the DRESP1 is the final one.

Known Error

CR 37227

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Description

Nonlinear Analysis - Creep Law May Cause Overflow - SFM 4276 in nmcrd Some forms of creep law may cause an overflow condition in nonlinear creep analysis. The error causes an overflow in the nmcrd subroutine which will be identified in the log file. Avoidance: A different creep law may avoid the error.

Known Error

CR 37247

Product

MSC / MD Nastran

Known Error

CR 37247

Corrected Version GL Abstract Description

Transient Analysis - TEMP(LOAD) - Wrong Answer In transient analysis, thermal strains are not subtracted from the total strains before computing the state of stress. This leads to wrong answers. Avoidance: This is a limitation, there is no avoidance.

Known Error

CR 37253

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Cyclic Symmetry - Virtual Mass, MFLUID - Wrong Answers Virtual mass will cause wrong results when used with cyclic symmetry if a fluid segment is modeled. This path should be blocked with a fatal error. Fully enclosed fluids in each segment will give correct answers. Avoidance: Use acoustic fluid elements instead.

Known Error

CR 37263

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Virtual Mass - MFLUID - PARAM,VMOPT,1 Does Not Function Properly When param, vmopt, 1 is present, the virtual mass should be added to the structural mass at the g-set, that is, before any constraints are applied. In Version 70.6 and 70.7 and V2001, setting this parameter has no effect and the solution method adds virtual mass after all constraints are applied. This may or may not affect the results Avoidance: The alter below will make vmopt, 1 take effect.

Description

compile semg list noref $ Alter 'if ( vmopt=1 and','' $ always do what user requests IF ( VMOPT=1 ) THEN $ Compile semrm list noref $ Alter 'if ( vmopt=0 or','' $ IF ( VMOPT=0 ) THEN $

Note that the original dmap would over-rule the user's request if it did not seem to "make sense". The alter always honors the vmopt request. Note that if vmopt=1 is used on medium- and large-size mode Known Error

CR 37264

Known Error

CR 37264

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Performance - MPYAD - MPYAD Method 1, Storage 2 not selected

Description

Under certain condition, the MPYAD Method 1, Storage 2 method, which is optimized for dense matrices, will not be correctly selected. This happens when all of the B and D matrices just fit into working memory. Avoidance: The work around is to either increase or decrease memory.

Known Error

CR 37284

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Utilities - MSGCMP.EXE, Windows NT - Missing Utility The msgcmp.exe executable is missing from the Version 70.5 NT release of MSC/Nastran.

Description

Avoidance: Download msgcmp.exe from the MSC ftp site or contact your local support person. The file is located in the /pub/outing directory. Since this is an executable, use the BIN option for downloading.

Known Error

CR 37290

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation/QRG - PARAM,POST - Patran may use the xdb

Description

The Quick Reference Guide documentation of parameter POST,0 does not mention the possibility to use the xdb database with MSC.Patran. This should be added and it should be clarified that the parameters MODEL and SOLID are not supported by MSC.Patran.

Known Error

CR 37291

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Description

Optimization/Design Sensitivity - GE - Wrong Sensitivities In a dynamic optimization job, if the design variables include damping coefficients and the adjoint method path is invoked, then the dynamic response sensitivity coefficients with respect to all design variables will be incorrect. This error has been corrected in Version 70.7.

Known Error

CR 37291 Avoidance: Turn off the adjoint method using the following dmap alter compile descon alter 'dsad'(1,-1) pexist = true alter 'dsad' pexist = false

Known Error

CR 37295

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation/QRG - MATHP - Poor Convergence The following sentence need to be added to the Quick Reference Guide description of the TAB1 parameter of the MATHP entry:

Description

Stresses are negative for compression and positive for tension. If this convention is not followed the job may fail to converge or issue a traceback.

Known Error

CR 37307

Product

MSC / MD Nastran

Corrected Version 2001.0.1 Abstract Description

Nonlinear Analysis - TEMP(MAT), HEXA - Wrong Equivalent Stress The "EQUIVALENT STRESS" for the nonlinear HEXA element is wrong if there are temperature dependent material properties. Avoidance: There is not avoidance.

Known Error

CR 37309

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

DMAP - APPEND - UFM 4276 EC 1039

Description

The APPEND module may fail and issue the message "USER FATAL MESSAGE 4276.OPENDV EC=1039" Avoidance: There is no avoidance. The error is fixed in Version 70.7.

Known Error

CR 37319

Known Error

CR 37319

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Optimization/Design Sensitivity - DESGLB - Unexpected Answers DESGLB is intended for the selection of design constraints at the global level (e.g., weight, volume). If DESGLB is used above the subcase level with the intent to apply the constraints to all the subcases, the constraints will be ignored for the second and subsequent subcases.

Description Avoidance: Use of the DESSUB above the first subcase applies it to all subsequent subcases until a new DESSUB request is entered. DESGLB is reserved for subcase independent response only. Known Error

CR 37335

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Restart - NMLOOP, LOOPID - Inefficient Restart, Modes Recalculated In a restart from SOL 106 to SOL 111, the stiffened modes are being recalculated unnecessarily. Avoidance: Insert the following dmap avoidance.

Description

compile semfreq $ alter 'call modefsrs'(,-1) $ equivx lama/lamas/-1 $ equivx pha/phsa/-1 $ if ( false ) then $ alter 'call modefsrs' $ endif $ endalter

Known Error

CR 37336

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

SSSALTERs - SEGYRO, CYGYR0 Alters - Wrong Results with Parameter DEPEND=-1 The SEGYRO alter puts the gyroscopic terms in the damping matrix and not in the mass matrix for param, depend,-1 and this leads to wrong answers. The assumption eigenvalue lambda = i*Omega is not valid in a rotating reference frame. The Corillis forces are equal to the mass times the cross product of the

Known Error

CR 37336 rotation vector times the velocity vector in the ROTATING SYSTEM. ie. f=m(omega X V ). The assumption that lambda is proportional to i*omega is only good for a limited set of response cases where the applied load has the same frequency as the rotations. An example would be an unbalanced turbine. The problem would diverge at the critical rotational frequency.

Known Error

CR 37341

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Static Analysis - PARAM,CDITER and INREL - Wrong Answers

Description

If PARAM,INREL,-1 is specified along with PARAM,CDITER,n then no message is issued stating that PARAM,INREL will be ignored The Version 70.5 Release Guide and QRG indicate that PARAM,CDITER and INREL are mutually exclusive. A fatal message will be issued in Version 2001.

Known Error

CR 37344

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Acoustic Analysis - ACSRCE, DAREA - Wrong Answers

Description

When using an ACSRCE power input during an acoustic frequency response analysis, if the scale factor on the DAREA is increased, then QDOT is erroneously factored instead of power. Avoidance: Scale the values on the TABLEDi instead.

Known Error

CR 37356

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Nonlinear Transient Heat Transfer - DLOAD - SFM3002 (TAH1)

Description

If transient thermal analysis loads (QVOL, QHBDY) are combined with temperature dependent material properties (MATT4), then the analysis will fail with SYSTEM FATAL MESSAGE 3002 in the TAHT module.

Avoidance: There is no avoidance. Known Error

CR 37382

Product

MSC / MD Nastran

Known Error

CR 37382

Corrected Version GL Abstract

Description

Nonlinear Analyis - CBUSH1D, PARAM,LGDISP - Wrong Answers Small initial values of stiffness for the CBUSH1D element, i.e. K=1, may lead to wrong results when PARAM, LGDISP,1 is specified. The problem occurs because the compression displacement is not limited to the length of the element. Avoidance: Specify a larger value for the stiffness.

Known Error

CR 37392

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Acoustic Analysis - CELAS1, CAABSF - UFM 5423 If frequency dependent elements are present in both the fluid (CAABSF) and the structure (CELAS1) then the run will fail with UFM 5423. Avoidance: Insert the following DMAP alter:

Description

compile freqrs alter 'if ( fs )'(2),'' if ( false ) then $ alter 'if ( fs )'(3),'' if ( false ) then $ alter 'if ( fs )'(4),'' if ( false ) then $ alter 'if ( fs )'(5),'' if ( false ) then $ endalter

Known Error

CR 37399

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Description

DMAP - OUTPTR Module does not Process STRAIN Requests The OUTPRT module introduced in Version 70.7 does not process STRAIN requests. As a results the partitioning vector that is generated will not include these points unless they are requested with other output requests. Avoidance: An avoidance is to also request STRESS for the same output set. At present, this module is used only in sssalter spdra.v707.

Known Error

CR 37400

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Description

P-Elements - RFORCE - Wrong Answers Wrong answers may be obtained when RFORCE is applied to p-elements where p>2. Avoidance: The only avoidance is to use the origin of the basic coordinate system to locate the rotation vector.

Known Error

CR 37402

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Optimization/Design Sensitivity - BNDGRID - UFM 6499(DOM9), UFM 9050(SEKRRS) When the C field on a BNDGRID entry in a shape optimization task is left blank or takes the value of zero, this input error is not detected. Therefore, the job may fail in one of the following ways:

Description

1. UFM 6499 (DOM9) due to a zero gradient of a violated constraint 2. UFM 9050 (SEKRRS) due to excessive pivot rations in Matrix KLL. 3. Wrong Answers Avoidance: Specify a non-zero component on the C field.

Known Error

CR 37403

Product

MSC / MD Nastran

Corrected Version 2001.0.1 Abstract

Description

DMAP - MATMOD - Wrong Answers If the first input, I1, to the MATMOD module, under option 12, is purged then the module will incorrectly report that NONULL=0 and the O1 output is purged without warning or fatal even if the second and third inputs (I2 and I3) are not purged and contain null columns. The documentation for MATMOD option 12 contained in the DMAP Module and Data Blocks Guide states that only I2 and I3 may be purged, which implies that a fatal message should be issued if I1 is purged. Avoidance: Rearrange the inputs so that the first input is not purged.

Known Error

CR 37407

Product

MSC / MD Nastran

Known Error

CR 37407

Corrected Version 2005.1 Abstract

Superelements - SEP1X, DTI, SETREE - SFM 4276 EC 3001 If external superelements are used in a multi-level model containing PART superelements (BEGIN SUPER), and the multi-level tree is defined using a DTI,SETREE entry, the run may fail in the SEP1X module with SYSTEM FATAL MESSAGE 4276. The fatal message will indicate that "ERROR 3001 HAS OCCURRED IN GREAD".

Description

Avoidance: Replace the DTI,SETREE entry with an SETREE entries. Actual error in DTI,SETREE where the user entry was DTI,SETREE,0 when the QRG stipulates DTI,SETREE,1 as the required starting format. Using the latter the job executes properly as a multi-level tree. Code corrected to use default of single level as a processing attempt, and for this job is also successful.

Known Error

CR 37411

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Parallel Processing - DMP - FATAL, Infinite CPU Loop If MSC.Nastran is run with DMP=n (n > 1) on an NEC system, and there is a FATAL message, then the processors which do not get the FATAL hang. They accumulate CPU time, but never finish. Avoidances: Avoidances are given below; however, this and several other problems related to DMP have been corrected in Version 70.7.2. DMP users should install this later version.

Description 1. Modify the $MSC_BASE/bin/nast707.lcl file: insert after line 294: %MSC_ARCH=superux:% errorcode=$? insert at the end of the file: %MSC_ARCH=superux:% exit $errorcode

2. Or run without DMP being specified. Known Error

CR 37437

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Frequency Response - dmp>1 and multiple FREQ subcases - Infinite loop

Description

A job with multiple frequency subcases submitted with Distributed Memory

Known Error

CR 37437 Parallel, dmp>1, in solution 111 will hang. Avoidance: Apply the following dmap alter: compile freqrs alter 'ckdd,cbdd'(,-1) $ putsys(1,287) $ alter 'ckddf,cbddf'(,-1) $ putsys(1,287) $ compile semfreq alter 'fs and'(,2),'' jump endloop $ alter 'if ( loopflag'(,-2) label endloop $ endalter

Known Error

CR 37454

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Parallel Processing - DMP, ITER=YES, SPCF - SFM If distributed memory parallel processing is specified with the iterative solver and spcforces are requested, the the job will fail.

Description Avoidance: Either do not request spcforces, distributed processing, or the iterative solver. Known Error

CR 37457

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Optimization/Design Sensitivity - PBARL, Smax, Smin - Possible Wrong Answers In an optimization run, if PBARL is used and only Smax or Smin is specified instead of the four stress data recovery points, then wrong answers may occur. Avoidance: There are two possible avoidances:

Description

1. Specify all four stress data recovery points instead of using Smax or Smin. or 2. Use PBAR instead of PBARL.

Known Error

CR 37458

Product

MSC / MD Nastran

Corrected Version 2001.0.1 Abstract

DBC - DBC, PARAM,POST - Job Crashes during BLKWRT A job with thousands of subcases may fail in DBC during a BLKWRT. The following message was encountered: MSC.XL DATA BASE CONVERSION STARTED

Description

PROJECT 0 0 0 0 0 00000 PATHQUAL 0 0 0 0 0 00000 PATHLINK 0 0 0 0 0 00000 PATHINT 0 0 0 0 0 00000 POST-PROCESSING DATA RECOVERY INITIATED SUBCASES 1 0 1 0 0 10000 ILLEGAL DATA BASE NUMBER PASSED TO BLKW

Known Error

CR 37462

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Parallel Processing - DMP>1, CBAR, CBEAM, SEQP - SFM 4276 If a statics job is submitted with Distributed Parallel Processing, dmp>1, and the job contains BAR or BEAM elements that specify disjoint GRID points for the orientation vector then the job may fail in the SEQP module or hang. Avoidance: There are several avoidances:

Description 1. Do not use distributed parallel processing. 2. Modify the CBAR, CBEAM entries to explicityly define a coordinate direction. 3. Modify the CBAR, CBEAM entry to reference an attached GRID point. 4. User Version 70.7.2 where this error has been corrected. Known Error

CR 37483

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Nonlinear Analysis - SFM 3007 (NLCOMB)/ILLEGAL INPUT TO SUBROUTINE NLCXGR

Known Error

Description

CR 37483 MSC.Nastran may fail with SYSTEM FATAL MESSAGE 3007 (NLCOMB), ILLEGAL INPUT TO SUBROUTINE NLCXGR on Sun/Solaris systems when run with MEM => 2Gb. Avoidance: Either: 1. Reduce memory below 2Gb 2. Run with version 70.7 or higher.

Known Error

CR 37485

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Description

Optimization/Design Sensitivity - Incorrect Sensitivities for Static Aero Incorrect sensitivities and subsequent poor optimization performance occurs on long word machines, such as the CRAY, for static aeroelastic sensitivity analysis when there are more design variables than there are AESTAT and AESURF entries. Avoidance: Run the job on a short word machine, reduce the number of design variables, or increase the number of AESTAT/AESURF entries to satisfy the above inequality.

Known Error

CR 37486

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

SSSALTERs - GPSP, PARAM,AUTOSPC - be-set dofs may be autospcd The be-set is a new set introduced in Version 70.7. It is not used in any solution sequences at present. Its only use is in the rflaga.v707 alter package.

Description

The be-set should not be autospcd, even when singular. This is analogous to the suport entry. It sometimes is autospcd, although the circumstances when this happens are not well understood yet. Avoidance: An avoidance is to always used an spcoff entry for every be-set point. It may not be necessary, but it should not cause problems either. Example uset, be, 17, 3 spcoff, 17 3

Known Error

CR 37487

Known Error

CR 37487

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Miscellaneous - USET - UFM 2104 (GP4), Poor Message The be-set is new in Version 70.7. When a degree-of-freedom is placed in a mutually exclusive set, such as the s-set, and the be-set, the following truncated message appears:

Description

*** USER FATAL MESSAGE 2101 (GP4) SCALAR POINT 1 ILLEGALLY DEFINED IN SETS US

The phrase "UBE" should also appear. If you see a message of this type look for be-set entries on the same dof . These dofs are entered on USET, BE-type inputs. Known Error

CR 37495

Product

MSC / MD Nastran

Corrected Version 70,7 Abstract

Description

Documentation - Hoffman's Theory incorrect in Composites Seminar Notes (NAS113) The Equation for Hoffman's Failure Theory in Chapter 5 of the NAS113 (Analysis of Composites Materials) semninar notes is incorrect. There is a sign error for one term. The term: (SIG1*SIG2) / (Xt*Xc) should be preceded by a negative sign in the equation.

Known Error

CR 37496

Product

MSC / MD Nastran

Corrected Version 2001 Abstract Description

Frequency Response - CELAS2 , STRESS - Wrong Answers In a direct frequency response analysis, the stress output for the CELAS2 element is incorrect. Avoidance: Use the CBUSH element instead,

Known Error

CR 37503

Product

MSC / MD Nastran

Corrected Version 2001.0.1 Abstract

Acoustic Analysis - Misleading UWM 5462 (IFS5P)

Known Error

CR 37503 The presence of acoustic elements always leads to the following misleading warning message:

Description

*** USER WARNING MESSAGE 5462 (IFS5P) OPTIONS IN PSOLID ID = 800000 FOR FLUID ELEMENT ARE NOT ALLOWED. DEFAULT VALUES WILL BE TAKEN. Avoidance: Ignore the warning message.

Known Error

CR 37585

Product

MSC / MD Nastran

Corrected Version 707 Abstract

Description

Case Control - SET - Duplicate Output If a SET command is used to request grid point output, and the set contains a thru range referencing non-existing grid points, then duplicate output will be printed for the last existing grid point. For the following example, no grid point exists between the range of 10001 and 10010, the displacement for grid point 12 is printed twice. SET 1 = 11,12 , 10001 THRU 10010 $ DISP(PHASE,SORT2) = 1

Avoidance: Remove the reference to the non-existing grid points in the set. Known Error

CR 37590

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

GPFORCE - GPFDR - Output does not include MPC forces in SOL 144 When Grid Point Forces (GPFORCE) are requested in SOL 144 (Static Aero), the forces of multipoint constraint (MPCFORCE) should be included in the output, but are not.

Description

Avoidance: Add the MPCFORCE=ALL or MPCFORCE(PLOT)=ALL output request to Case Control to cause the MPC forces to be computed. Once computed, they will be included in the GPFORCE output.

Known Error

CR 37593

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Superelements - CSUPER, STATSUB, SPC - UFM 1126 (GNFIST)

Known Error

CR 37593 In a normal modes analysis with image superelements (CSUPER), if the structure is preloaded (STATSUB) and spcs are applied to the interior of the primary superelement, then the job will fail with the following unclear error messages:

*** USER FATAL MESSAGE 1126 (GNFIST) DMAP MODULE MATREDU IS ATTEMPTING TO OUTPUT DATABLOCK 202 NAME = KDSF , WHICH ALREADY EXISTS. USER ACTION: DELETE THE DATABLOCK, OR USE FILE KDSF=OVRWRT Description Avoidance: Replace the following nddl statement PATH KDSF PEID,MPC,SPC,MTEMP,NLOOP,DESITER,PVALID, APRCH,HIGHQUAL,K2GG,M2GG,AUXMID,STATSUB,P2G $

with PATH KDSF seid,PEID,MPC,SPC,MTEMP,NLOOP,DESITER,PVALID, APRCH,HIGHQUAL,K2GG,M2GG,AUX Known Error

CR 37597

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

SSSALTER - delmodea.vxx, Part Superelements - Modes Not Deleted When using the delmodea.vxx alter with PART superelements, and the DMI,SKPMODE entry is placed in the main bulk data section, then selected modes will not be deleted. The following warning messages will be issued:

Description

^^^ USER WARNING MESSAGE: MODE PARTITIONING MATRIX NOT FOUND IN BULK DATA ^^^ PLEASE CHECK INPUT DECK FOR DMI, SKPMODE ENTRIES ^^^ ^^^ THE MODE DELETION ROUTINE CANNOT CONTINUE - NORMAL PROBLEM SOLUTION CONTINUING WITH ALL MODES... Avoidance: Either request a copy of the updated alter from your local support engineer or put the DMI, SKPMODE in the last partitioned bulk data section.

Known Error

CR 37598

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Parallel Processing - DMP, Component Modes - Infinite loop If distributed parallel processing is selected by setting dmp>1 on a component modes analysis the job may hang. Avoidance: Insert the following DMAP alter:

Description

compile cmpmode alter 'xofp' if ( getsys(np,265)>1 ) then $ delete /cmlama,cmphixz,cmmi,cmoeigs,eigvmats $ disutil ,,,,/cmlama///3 $ disutil ,,,,/cmphixz///3 $ disutil ,,,,/cmmi///3 $ disutil ,,,,/cmoeigs///3 $ disutil ,,,,/eigvmats///3 $ paraml cmphixz//'trai

Known Error

CR 37600

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Nonlinear Analysis - PSHELL - Incorrect NLSTRESS Format The NLSTRESS format is wrong if both plane-strain and plane-stress shell elements exist in the same input file. That is if multiple PSHELL records exist, some with MID2>-1 and some with MID2=-1.

Description

Avoidance: This output can be turned off by requesting NLSTRESS=NONE. Another avoidance is not to put both types of shell elements into a single nonlinear run. The other results (including the stresses using the linear format) are not affected.

Known Error

CR 37602

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Static Analysis - DMP, dmp>1 and iterative solver - SFM 4276 (UNPACK) If a SOL 101 run is made with Distributed Memory Parallel and the iterative solver is selected, then the job may crash with the following message:

Description

*** SYSTEM FATAL MESSAGE 4276 (UNPACK) ERROR CODE 20 PID= 0

Known Error

CR 37602 Avoidance: Do not use DMP. The error is corrected in Version 70.7.2

Known Error

CR 37606

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Parallel Processing - DMP>1 and mergeresults=yes, OLOAD - Wrong Answers In static analysis with domain decomposition (a.ka., Distributed Memory Parallel, dmp>1) and mergeresults=yes on the nastran submittal line, the OLOAD output and OLOAD maximums will be wrong for the boundary points if distributed loads like PLOAD and GRAV are applied. Avoidance: Insert the following DMAP alter:

Description

compile sedisp alter 'pj0s','pj0s'(,1) upartn usetx,pj/pax,pga,,/'g'/'a'//1 $ merge ,,pax,,,,spcpart/pag0/1 $ Loads at boundary due to local $ distributed loads DISUTIL pag0,,,/pg0///8 $ sum of all boundary dist. loads disutil pg0,,,/pg00///3 $ broadcast to slaves if ( getsys(np,265)>1 ) equivx pg00/pg0/-1 $

Known Error

CR 37615

Product

MSC / MD Nastran

Corrected Version 2001.0.1 Abstract

Eigenvalue Analysis - EIGRL - UWM 4698 (DCMPD), SFM 7340 When Lanczos encounters a massless mechanism it will first provide the following message:

Description

*** USER WARNING MESSAGE 4698 (DCMPD) STATISTICS FOR DECOMPOSITION OF MATRIX (NONE) . THE FOLLOWING DEGREES OF FREEDOM HAVE FACTOR DIAGONAL RATIOS GREATER THAN 1.00000E+15 OR HAVE NEGATIVE TERMS ON THE FACTOR DIAGONAL. GRID POINT ID DEGREE OF FREEDOM MATRIX/FACTOR DIAGONAL RATIO MATRIX DIAGONAL

Known Error

CR 37633

Product

MSC / MD Nastran

Corrected Version GL

Known Error

CR 37633

Abstract

Restart - EIGRL, EIGR - Inefficient Restart

Description

In a restart run, if an unreferenced EIGRL (or EIGR) is added to the restart run input, then the modes will be recalculated even though the entry is not referenced. Avoidance: Remove the unreferenced EIGRL/EIGR entry.

Known Error

CR 37635

Product

MSC / MD Nastran

Corrected Version GL Abstract

Nonlinear Transient Analysis - RESTART, PARAM,G, GE -Different Answers In a nonlinear transient restart analysis, if large displacement is turned on (param,lgdisp,1), and param W3 damping exists in the model (with PARAM,G ), the results may be different than the one in the coldstart run. The difference is due to the possible non-syncronization of the stiffness update between the coldstart and restart runs.

Description

Avoidance: Recommended damping in nonlinear transient (SOL 129) is param, W4 damping with GE value in MAT1. If stiffness update syncronization is desired with param W3 damping, set KSTEP=1 to force the stiffness update. Care must be exercise when there is adaptive gap element since the penalty stiffness can be fictituously high inducing an unrealistic high damping force.

Known Error

CR 37642

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

Description

Restarts - CBUSH, CAABSF, GMINTS, GMINTC - SWM 2072 If a model contains CBUSH elements, then upon RESTART SYSTEM WARNING MESSAGE 2072 will be issued by the RESTART module when it compares the GEOM2 data block. A similar error can occur if the model contains CBEND, CAABSF, GMINTS, or GMINTC entires. Avoidance: No avoidance is necessary, ignore the message.

Known Error

CR 37646

Product

MSC / MD Nastran

Corrected Version 2001

Known Error

CR 37646

Abstract

Documentation/QRG - CSUPER - Improve Remark 3 of CSUPER Entry Remark 3 of the description of the CSUPER bulk data entry in the QRG should be improved to read:

Description

3. For identical or mirror image superelements, the grid point IDs, GPi, may appear in any order. However, if they are not in the same order as the external GRIDs of the primary superelement, then the SEQSEP entry is also required. In case of external superelements, the GRID IDs must be in the order that the terms in the associated matrices occur in.

Known Error

CR 37653

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - CREEP - Thermal Correction

Description

The Quick Reference documentation for the CREEP entry should be changed to further explain what turns on the thermal correction for the creep strain rate. If the T0=0.0 or blank, then the thermal correction is not utilized. However if PARA,TABS is used, TABS is added to T0 and then the thermal correction is utilized even if T0 is blank or 0.0. If thermal correction is utilized then, EXP must be meaningful and have the consistent units.

Known Error

CR 37661

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Description

Superelement - Repeated SUPER Command - UFM 7323, Possible Wrong Answers If the SUPER case control command is repeated incorrectly as shown below . subcase 100 super = 0,1 . subcase 200 super = 0,2 . subcase 300 super = 0,1 . then following unclear fatal message is issued *** USER FATAL MESSAGE 7323 (SEDRA) SUBCASES FOR SUPERELEMENT 0 HAS A LOAD SEQUENCE NUMBER = 1 WHICH IS OUT OF ORDER.

Known Error

CR 37661 The job will continue to execute and the results are unpredictable. Avoidance: Correct the offending SUPER case control command.

Known Error

CR 37700

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Parallel Processing/Statics - Distributed Memory Processing - SFM 7492 If DMP is specified on the command line for a SOL 101 run, the following error message may appear:

Description

*** SYSTEM FATAL MESSAGE 7492 (PRESOL) INCONSISTENT VALUE FOR NUMBER OF LOCAL GRIDPOINTS ON PROCESSOR 1: ACCORDING TO SIL TABLE, THE NUMBER OF LOCAL GRIDPOINTS IS 100763 ACCORDING TO GEQMAP, THE NUMBER OF LOCAL GRIDPOINTS IS 101073 USER ACTION: PLEASE CONTACT MSC.SOFTWARE CLIENT SUPPORT. Avoidance: Do not use DMP. This error is corrected in Version 70.7.2.

Known Error

CR 37719

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Documentation - V70.7 Release Guide - DCMPSEQ Section 2.7 of the Version 70.7 Release Guide documents a new keyword "DCMPSEQ". This section of the guide does not give examples and it contains a typo. The Guide states that this keyword is the same as SYSTBM(206), this is a typo, it should be SYSTEM(206). It states that the new option is invoked by adding 64 to the value of the keyword; however the default of SYSTEM(206) is not documented. The default value of SYSTEM(206) is 4 for all systems except NEC, the default for NEC is 0. This keyword must be set on the NASTRAN command line in the input deck. For all systems except NEC the input to activate this option is: NASTRAN DCMPSEQ=68 or

Known Error

CR 37719 NASTRAN SYSTEM(206)=68

Known Error

CR 37748

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Miscellaneous - V70.7, New Log File Messages - Wrong DOF Output The following new messages are sent to the log file in Version 70.7:

Description

10:32:43 Finite element model generation started. 10:32:43 Finite element model generated 1 degrees of freedom. 10:32:43 Finite element model generation successfully completed. The second message above always reports 1 DOF which is in almost all cases wrong.

Known Error

CR 37764

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Parallel Processing/Frequency Response - DMP, PARAM,RESVEC - UFM Distributed Memory Parallel frequency response analysis will fail when PARAM,RESVEC,YES is used to specify residual flexibility. Avoidance: Either: 1) Run using a newer version (V70.7.2 or newer) 2) Do not use residual vectors with dmp 3) Insert the following DMAP alter:

Description

compile resvec alter 'read '(,-1) $ For dmp>1, deactivate parallel np=getsys(np,197) $ capture NUMSEG if( np>1 ) putsys(0,197) $ set NUMSEG=0 alter 'read ' if( np>1 ) putsys(np,197) $ restore NUMSEG compile cmpmode alter 'read ' if ( getsys(np,197)>1 and getsys(np,265)>1 ) then $ $ Since the master node has all modes, then $ then we will generate a dummy mode on the $ slaves to avoid hang-ups. delete /cmlama,cmphixz,cmmi,cmoeigs,eigvmats $

Known Error

CR 37773

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Description

Matrix Methods - PARTN/MERGE - Poor Performance The PARTN and MERGE modules perform poorly when the partitioning vectors are purged. Avoidance: There is no avoidance but this has been corrected in Version 70.7.2.

Known Error

CR 37775

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Miscellaneous - Q4SKEW,Q4TAPER, TETRAAR, and T3SKEW do not work in Unix rcfile On unix workstations, if you attempt to set SYSTEM cells 189, 190, 191, or 218 in the "rcfile" using the cell name (Q4TAPER, Q4SKEW, TETRAAR, T3SKEW), the default values will be used for these cells with no warning messages issued,

Description

Avoidance: Use the SYSTEM cell number in the "rcfile" for these cells. For example: nastran system(189)=1. nastran system(190)=1. nastran system(191)=100. nastran system(218)=1.

Known Error

CR 37793

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Nonlinear Normal Modes - RESTART, PARAM,FOLLOWK - Wrong Answers

Description

Nonlinear normal mode analysis by a restart in SOL 103 from SOL 106 database gives erroneous solution in presence of follower forces in Version 70.7. The follower stiffness is not included in this restart runs. This error may be avoided if the normal mode analysis is performed in SOL 106 during the coldstart run, or SOL 103 is used with a statsub option for the preload. However, a restart procedure is required if free-free modes are subject to a nonlinear deformation under the preload.

Known Error

CR 37793 Avoidance: For free-free modes, insert the following DMAP alter into the SOL 103 restart compile semg alter 'call semg1' type parm,,char8,y,followk='yes' $ TYPE PARM,,RS,N,stol=0. $ type db slt $ dbstatus slt//s,n,noslt $ PARAML CASES//'DTI'/COLNO/4//S,N,LOADID $ if ( followk='yes' and noslt>0 and loadid>0 and seid=0 ) then $ TAFF SLT,BGPDTS/ESTF,GPECTF/ LUSETS/LOADID/0/1. $ EMG ESTF,CSTMS,MPTS,DIT,,UGni,ETT,EDT, DEQATN,DEQIND,BGPDTS,GPSNTS,,,,/ KFELM,KFDICT,,,,/ 1/0/0//1/////////-1/1. $ EMA GPECTF,KFDICT,KFELM,BGPDTS,SILS,CSTMS,,/ KFGG0,/-1 $ dbview cstm0=cstms where (peid=0) $ emakfr bgpdts,cstms,slt,mjj,cstm0,scstm/ kfrfgg/loadid $ rforce stiffness ADD5 KFGG0,kfrfgg,,,/Kfgg $ PARAML KFGG//'TRAILER'/3/S,N,UNSYM//S,N,NOKFGG $ IF ( UNSYM6 AND NOKFGG>-1 ) THEN $ $ Symmetrize stiffness matrix if unsymmetric TRNSP KFGG/KFGGT $ ADD5 KFGG,KFGGT,,,/KF/1./-1. $ norm kfgg/dummy///s,n,xnorm/1 $ stol = xnorm*1.e-11 $ tolerance recommended matmod kf,,,,,/kfa,/2////stol $ paraml kfa//'null'////s,n,notnull $ if ( notnull=-1 ) modtrl kfgg////6 $ symmetric ENDIF $ UNSYM6 AND NOKFGG>-1 add kfgg,kjj/kfjj $ equivx kfjj/kjj/-1 $ ENDIF $ FOLLOWK='YES ' endalter

Known Error

CR 37797

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Documentation - diag= keyword does not work for all diags

Known Error

Description

CR 37797 The "diag" command line keyword does not work for all possible diag flags. In particular, diag flags 5 and 6 cannot be set from the command line or an RC file. Avoidance: Set these diags in the bulk data file using the standard DIAG statement, DIAG 5,6

Known Error

CR 37799

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Optimization - DRESP2, DRESP1 - SFM 3007 (DOPR3) In an optimization run, if a DRESP2 references both DRESP2 and DRESP1, and the DRESP1 references a property PTYPE (e.g., PBAR) which points to more than one element, then the job will fail with the following error messages: *** SYSTEM FATAL MESSAGE 3007 (DOPR3) ILLEGAL INPUT TO SUBROUTINE DOPR3J 0FATAL ERROR

Description

*** SYSTEM INFORMATION MESSAGE 1156 (XCLNUP) GINO FILE 110 WAS LEFT OPEN AT PROGRAM TERMINATION. Avoidance: There are two possible avoidances: 1. Avoid referencing a DRESP2 with a DRESP2, reference a series of DRESP1 instead. 2. Reference ELEM instead of property on the PTYPE field on the DRESP1 entry.

Known Error

CR 37805

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Description

Optimization/Design Sensitivity - ANALYSIS=MFREQ - UFM 9068 The message "USER FATAL MESSAGE 9068 NO DRESP1 OR DRESP2 ENTRIES EXIST FOR DESOBJ=n" may be issued in error for a solution 200 analysis that contains only frequency or transient analysis subcases and the objective is a WEIGHT or VOLUME response. The fatal will only occur if the DRESP1 ID that is just below the ID called out by the DESOBJ request has a blank ATT1 field on the DRESP1 bulk data entry; i.e., the response is RTYPE = EIGN, FREQ or LAMA. Avoidance: Provide an ID on the DRESP1 entry for the WEIGHT or VOLUME

Known Error

CR 37805 objective that is lower than any other DRESP1 ID or ensure that the ID that is just below the objective ID has a non-blank ATT1 value.

Known Error

CR 37806

Product

MSC / MD Nastran

Corrected Version 2001.0.1 Abstract

Documentation - V70.7 Release Guide Release Notes, p50, "File Size Reduction for Modal Frequency Response"

Description

The efficiencies described in this section require the use of sssalter spdra.v707, available on the msc internal web site. Contact your local MSC Technical Representative to get a copy of this dmap alter.

Known Error

CR 37812

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

P-elements - InterFace Elements - Incorrect EPSILONs

Description

The EPSILON table produced when interface elements are used is incorrect in the NEC Version 70.7.0 release of MSC.Nastran The EXTERNAL WORK is correct however. Avoidance: There is on known avoidance. The error has been corrected in Version 70.7.2.

Known Error

CR 37832

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Heat Transfer - TSTRU, TEMP(INIT) - SFM 3001(TA1) If TEMP(INIT) is set to the same ID as TSTRU then the job will fail with the message:

Description

*** SYSTEM FATAL MESSAGE 3003 (TA1) ATTEMPT TO READ PAST THE END OF A LOGICAL RECORD IN DATA BLOCK ETT (FILE 106) IN SUBROUTINE TA1ETD Avoidance: Specify a different set ID for TEMP(INIT).

Known Error

CR 37833

Known Error

CR 37833

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Installation - INSTALL.txt and INSTALL.htm on CD state incorrect MPT version

Description

The files INSTALL.txt and INSTALL.htm on the V70.7 CD state that for running distributed parallel MSC.Nastran on SGI R8K/ R10K/R12K, MPT 1.5 is required. This is a typo, MPT 1.3 is required.

Known Error

CR 37834

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Estimate - buffsize=estimate keyword broken in V70.7 In Version 70.7, if the keyword buffsize=estimate is used, then the job will fail with the following error messages in the f06 file. NASTRAN BUFFSIZE=ESTIMATE $(/USERS/SWAN/.NAST707RC[26]) *** USER FATAL MESSAGE 17 (LOOKUP) SYMBOL "ESTIMATE" IS UNDEFINED followed later by:

Description

*** USER WARNING MESSAGE 782 (SYSCHK) THE NASTRAN BUFFSIZE PARAMETER CANNOT BE SMALLER THAN MACHINE DEFAULT = 2049 USER INFORMATION: NASTRAN BUFFSIZE PARAMETER IGNORED. USER ACTION: USE THE INIT FMS STATEMENT TO SET THE DESIRED BUFFSIZE FOR EACH INDIVIDUAL DBSET. *** USER INFORMATION MESSAGE 480 (SYSCHK) JOB TERMINATED DUE TO ABOVE ERROR(S) IN THE NASTRAN STATEMENT PROCESSOR. FATAL ERROR Avoidance: Specify a specific buffsize.

Known Error

CR 37835

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Installation - HP-UX, Install Script Reports No Disk Space Available

Description

Under some circumstances on HP-UX systems, mscsetup may report "0 MB" disk space available on NFS or automounted filesystems. The full circumstances

Known Error

CR 37835 are not yet known. Note: The error is a direct result of incorrect information being returned from the df(1) command on HP-UX 10.20 and 11.00. The specific command used by mscsetup is "df -k", and sample output showing the error is: $ df -k /net/trinity/scratch /tmp_mnt/net/trinity/scratch (trinity:/scratch ) : 0 total allocated Kb 0 free allocated Kb 0 used allocated Kb 45 % allocation used Another invocation of df, that does not return sufficient i

Known Error

CR 37837

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Documentation/Estimate - Minimum Values The ESTIMATE utility will apply a minimum value to estimates for the following:

Description

Parameter Keyword Default Value (MB) --------- ---------- -----------------memory memmin 16 disk dskmin 1 sdball dballmin 1 scratch scratchmin 1 scr300 scr300min 1 The minimum value is applied after the conservative value (i.e., "memco", "dskco", "dballco", "scratchco", and "scr300co" respectively). Thus, setting "memco=0.5" to reduce all memory estimates by 50% will have *no* effect if the estimate falls below the minimum value.

Known Error

CR 37843

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Loads - PLOAD4, Large Field Format - UFM 4577 (GP3C)

Description

If a PLOAD4 references an element with large field format, the job may fail

Known Error

CR 37843 with the message: USER FATAL MESSAGE 4577 (GP3C) PLOAD4 LOAD SET= 1 REFERENCES ELEMENT ID =******************* WHICH WAS NOT FOUND AMONG TRIA3, TRIA6, QUAD4, QUAD8, HEXA, OR PENTA ELEMENTS Avoidance: There is no avoidance other than renumbering the elements.

Known Error

CR 37844

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Accounting - XSEMDR - Can not Determine Solution Sequence In releases prior to Version 70.7 the f04 Execution Summary ended with the last module specific to the solution. Beginning in Version 70.7 the f04 Execution Summary ends with the last line XSEMDR END. For example:

Description

13:19:02 0:13 212.0 0.0 12.8 0.0 NLTRAN 527 EXIT BEGN 13:19:02 0:13 212.0 0.0 12.8 0.0 XSEMDR END This prevents the accounting program provided my MSC which reads the last line from determining the solution sequence.

Known Error

CR 37859

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Miscellaneous - Missing TPL file mcso42.dat in V70.7

Description

The file mcs042.dat was missing from the Version 70.7 tpl. It has been added to the Version 70.7.2 tpl.

Known Error

CR 37862

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

Miscellaneous - FLEXlm can not be used with system checkpoint capabilities MSC.Nastran jobs (as well as any other program) that use FLEXlm licensing or any other socket-based communications cannot be checkpointed by system-level checkpoint/restart capabilities, such as SGI's cpr utility. If attempted messages similar to the following will be issued in the log file:

Known Error

CR 37862 Checkpointing id 259527 (type PID) to directory /tmp/test.cpr CPR Error: Uncheckpointable fd, pid 259527 fd 10 type socket Checkpoint failed. Restarted all processes back to their running states CPR Error: ckpt_create child failed: errno 47 (Checkpoint/Restart error) Failed to checkpoint process 259527 --------------------------------Avoidance: Use a node-lock authorization code for licensing and avoid the use of any socket connections by MSC.Nastran.

Known Error

CR 37872

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

SSSALTERs - checka, PARAM,LANSUP - SFM 3007 If PARAM,LANSUP,1 is used in the checka sssalter in version 70.5, 70.6, or 70.7, the run will fail with SYSTEM FATAL MESSAGE 3007 indicating an illegal operation while merging matrices. Avoidance: Replace:

Description

UMERGE USET,DMI,Dar/DM1/'A'/'R'/'L' $ DN changed to DAR with: equivx dar/dm1/-1 $

Known Error

CR 37873

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Old Design Sensitivity - SFM 3001, MPTS Does Not Exist If the old sensitivity (SOL 103) is used and no material entries are present, the run will fail with SFM 3001 indicating that data block MPTS does not exist.

Description Avoidance: 1) use SOL 200 to perform similar task or 2) or add a dummy material to the input file if the old dsa is used. Known Error

CR 37880

Product

MSC / MD Nastran

Corrected Version 70.7.2

Known Error

CR 37880

Abstract

Parallel Processing - DMP - SPCForce Output with Multiple Subcases - UFM 5423 Distributed Memory Parallel jobs, dmp>1, with multiple subcases will fail with the following message if spcforce output is requested. *** USER FATAL MESSAGE 5423 (SADD5) ATTEMPT TO ADD INCOMPATIBLE MATRICES, (SADD5)

Description

COLS ROWS FORM TYPE NZWD DENS TRAILER FOR QG0S IS 1 450 2 2 0 0 TRAILER FOR QGI IS 2 450 2 2 24 267 0FATAL ERROR Avoidance: Either do not select dmp or do not select spcforces.

Known Error

CR 37886

Product

MSC / MD Nastran

Corrected Version 2001 Abstract Description

Nonlinear Analysis - RFORCE, PARAM,FOLLOWK - Poor Performance EMAKFR Nonlinear analysis of large problems with RFORCE as a follower force may exhibit poor performance in EMAKFR. Avoidance: There is no avoidance.

Known Error

CR 37892

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Description

Documentation/COG - V70.7 smaster=estimate fails The "MSC.Nastran V70.7 Configuration and Operations Guide" incorrectly states that "smaster=estimate" is valid, it is not. Avoidance: Set an actual size if the MASTER DBSet default size needs to be increased.

Known Error

CR 37898

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Superelements - SDAMPING; PARAM,SESDAMP,YES - NORM=MAX or POINT, Wrong Answers

Description

Superelement modal damping (PARAM,SESDAMP,YES) produces incorrect answers

Known Error

CR 37898 when MAX or POINT normalization is selected on the EIGR or EIGRL entries. Avoidance: Use MASS normalization which is the default. Verified in R.32. -TIN-

Known Error

CR 37907

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Optimization/Design Sensitivity - DRESP1, PCOMP - UFM 5503 The message: UFM 5503 ELEM NO. n PLY NO.y REFERENCED ON A DRESP1 ENTRY COULD NOT BE FOUND

Description

may be issued in error for composite responses (DRESP1 RTYPE=CSTRESS,CSTRAIN or CFAILURE) if the SOUTi requests on the underlying PCOMP entries have different values for the different layers (i.e., some are YES and some are NO or blank). Avoidance: Make all the SOUTi requests on a given PCOMP entry the same if design responses are to be imposed on elements associated with the PCOMP.

Known Error

CR 37913

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Submittal - nastran Command does not recognize LSF Submittal The nastran command does not automatically recognize a submittal via LSF. For NQS, the nastran command will recognize it is running in a batch job and set the defaults batch=no and notify=no. In addition, if submitted as a DMP job by LSF, the nastran will not recognize the list of selected hosts.

Description

Avoidance: The problem may be avoided by: 1. set notify=no and batch=no in an RC file or on the command line when running under LSF. 2. Set hosts=$(print $LSB_HOSTS | sed 's/^ *//;s/ *$//;s/ */:/g') on the command line when running a DMP job under LSF

Known Error

CR 37918

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation/DMAP - DISUTIL not documented The MSC.Nastran DMAP Modules and Datablocks CD for Version 70.7 mentions, but does not document the module DISUTIL The following is the documentation for this module:

Description

Broadcast data blocks between slave and master processors for parallel processing. Additional processing may occur on the master processor. Format: Format for DISMETH=1 or 2: DISUTIL B,X,R,EQMAP/ EPSSE/ NSKIP/S,N,EPSI/1 or 2 $ Format for DISMETH=3 on master processor: DISUTIL DB,,,////3 $ Format for DISMETH=3 on slave processor: DISUTIL ,,,,/DB///3 $ Format for DISMETH=4 or 5: DISUTIL RESMAX,RESMAX0,CASECC,HEADCNTL////4 or 5 $ Format for DISMETH=6: DISUTIL UG,SPCPART,GEQMAP,/UGG///6 $ Format for DISMETH=7: DISUTIL PG,SPCPART,GEQMAP,/PGG///7 $ Format for DISMETH=8 or 9 on master processor: DISUTIL MATS,,,

Known Error

CR 37925

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Optimization/Design Sensitivity - PCOMP - UFM 5629 (DSAD1C) If RTYPE=STRESS or STRAIN in a composite optimiztion deck with NOCOMPS=1, the following fatal message is issued.

Description

*** USER FATAL MESSAGE 5629 (DSAD1C) THERE ARE DRESP1 ENTRIES FOR RESPONSE TYPE = STRESS BUT THERE ARE NO CORRESPONDING OUTPUT RESPONSES. Avoidance: There is no avoidance. Users need set nocomps=0 or -1.

Known Error

CR 37932

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Optimization/Design Sensitivity - DVMRELi, DVCRELi, scr=no - Wrong Answers In an optimization run, if the design variables involve material properties (DVMRELi) or connectivity (DVCRELi) only, and scr=no is used, then the run will converge prematurely. A symptom of this problem is the unexplainable job termination after the first design cycle with no change in the objective function. Avoidance: Run the job with scr=yes or insert the following alter:

Description compile update alter 'RESTART EPTS,EPTSP' DBVIEW mPTSP=mPTS WHERE (DESITER=DESP) $ RESTART mPTS,mPTSP,/UHIST $ DBVIEW geom2SP=geom2S WHERE (DESITER=DESP) $ RESTART geom2S,geom2SP,/UHIST $ endalter Known Error

CR 37944

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Documentation - VECPLOT - DMAP Module and Datablock Dictionary The Version 70.7 DMAP Module and Data Blocks Dictionary has incorrectly indicates that the VECPLOT module has only one output datablock. Starting in Version 70.7 the VECPLOT module has two output datablocks. This is correctly documented in the V70.7 Release Notes.

Known Error

CR 37952

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Documentation/COG - Estimate Program, Precedence of Keywords The precedence of ESTIMATE processed keywords in the MSC V70.7 Configuration and Operations Guide listed in Section 6.2 should be as follows:

Description

1) ESTIMATE keywords, which are also NASTRAN keywords that are recognized in the bulk data file (Example: NASTRAN BUFFSIZE=4097)

Known Error

CR 37952 2) ESTIMATE keywords on the command line, Example: msc707 estimate myjob.dat memco=2.5 Note: NASTRAN only keywords will cause an error (example: auth=1700@server) 3) ESTIMATE keywords, which are also NASTRAN keywords, contained in the nastran INI and/or RC files (example: buffsize) 4) ESTIMATE keywords contained in data-file-directory/.estimaterc on UNIX, or data-file-directory\estimate.rcf on NT, where data-file-directory is the directory containing the input data file 5) ESTIMATE keywo

Known Error

CR 37969

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Superelements - Poor Message, UFM 6790 (SEPO21)

Description

UFM 6790 shown below is output when a list superelement has no points that can be identified as boundary points. The fatal message is followed by table print which may be ignored. *** USER FATAL MESSAGE 6790 (SEPO21) THE FOLLOWING SUPERELEMENTS ARE DETACHED: 1 3 62000000007 52000000008 212000000002 222000000003 232000000004 242000000005 252000000006 61101529088 71102053376 81102577664 91103101952 101103626240 11 22000000001 42000000007 52000000008 212000000002 22 2000000003 232000000004 242000000005 252000000006 -1 0 0 0 0 0

Known Error

CR 37978

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Nonlinear Analysis - HEXA - Poor Convergence for Small Loads

Description

Geometric nonlinear analysis (SOL 106 with PARAM LGDISP > 0) with solid elements and extremely small loads may fail to converge.

Known Error

CR 37981

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Nonlinear Analysis - UWM 5426 for DEFORM Entry Should be a FATAL Using a DEFORM entry in the case control for SOL 106 (nonlinear statics) will produce: *** USER WARNING MESSAGE 5426, DEFORM BULK DATA CARDS REFERENCED BY DEFORM CASE CONTROL COMMAND ARE NOT DEFINED. THE REQUEST FOR STRESSES AND/OR FORCES IS IGNORED.

Description

This will cause data recovery for stresses and/or forces to be ignored. It will also lead to misleading results, because the DEFORM entry is not applicable to Sol 106. Recommendations: 1) change Warning 5426 to Fatal for sol 106 2) Add the following remark to Deform Bulk data section: 4. The deform entry, when called by the deform case control command, is applicable to linear static, inertia relief, differential stiffness, and buckling (Solutions 101,105,114, and 200) and will produce fatal messages in other solution

Known Error

CR 37990

Product

MSC / MD Nastran

Corrected Version GL Abstract

Nonlinear Analysis - Beam with Warping Failed to Converge - SFM 4549 BEAM elements with warping are not allowed in geometric nonlinear analysis.

Description

A nonlinear analysis of a CBEAM with the warping degree of freedom specified may results in failed convergence or SFM 4549 followed by a traceback: SYSTEM FATAL MESSAGE 4549, SINGULAR (C+KBRR) MATRIX ENCOUNTERED FOR BEAM ELEMENT 1001 Traceback: Offset 0x00003e28 in procedure nmepd_

Known Error

CR 37990 Offset 0x000009d0 in procedure nmatd_ Offset 0x000022dc in procedure nbem2d_ Offset 0x0000017c in procedure nembrd_ Offset 0x00001124 in procedure nlemg_ Offset 0x00000790 in procedure nliter_ Offset 0x00000088 in procedure xsem15_ Offset 0x00000990 in procedure mainal

Known Error

CR 38012

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation/QRG - PARAM,FOLLOWK

Description

The Quick Reference Guide incorrectly states that PARAM,FOLLOWK is available only in solutions 103, 105, and 107. It is also available in solutions 108, 109, 111, and 112.

Known Error

CR 38013

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract Description

DMAP - PARTN - TYPE is Ignored Specification of TYPE is ignored in the PARTN module. This may cause a problem in user dmaps. The avoidance is dependent on the intent of the DMAP.

Known Error

CR 38016

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Description

Superelements - SESET failures in SEP1X using THRU range entry It has been observed that the SESET entry may cause failures when a THRU range is specified where the low GRID ID is less than the starting GRID ID of the model. Avoidance: An avoidance is to make the starting grid equal to the low the low grid identification.

Known Error

CR 38021

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Documentation/COG - Fujitsu, XDB, TRANS

Known Error

CR 38021

Description

The V70.7 Configuration and Operations Guide states that the Fujitsu VPP,Vx UXP/V systems require that the XDB file be translated. This information is incorrect. The correct line would be similar to that of HP HP-UX right underneath the Fujitsu line.

Known Error

CR 38023

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation/QRG - PBEAML - NSM(B) not included on PBEAML entry

Description

The Quick Reference Guide incorrectly omits the field for the NSM (nonstructural mass) on end B of the PBEAML entry. The last field on this entry is the NSM for end B.

Known Error

CR 38031

Product

MSC / MD Nastran

Corrected Version GL Abstract Description

Nonlinear Transient Thermal Analysis - Missing Results from XDB A multiple subcase transient thermal analysis will be missing temperature results in the OP2 and/or XDB files for the 2nd and subsequent subcases. Avoidance: A DMAP avoidance is under investigation.

Known Error

CR 38041

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Optimization/Design Sensitivity - DESGLB, GRAV, Multiple Subcases - UFM 5423 In an optimization run, if the DESGLB global constraint is used, and there are two or more static subcases with gravity loads, then the job may fail with the following error messages: *** USER FATAL MESSAGE 5423 (SADD5) ATTEMPT TO ADD INCOMPATIBLE MATRICES, (SADD5)

Description

COLS ROWS FORM TYPE NZWD DENS TRAILER FOR EGM IS 2 80532 2 2 1830 114 TRAILER FOR EGKL IS 1 80532 2 2 10976 681 0FATAL ERROR

Known Error

CR 38041 Avoidance: Use the DESSUB constraint callout instead.

Known Error

CR 38046

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Miscellaneous - OUTPUT2, TABPRT - Incorrect Format Field Output datablocks (OFP tables) contain information in the header record which describes the information contained in the datablock. Word 9 is used to indicate if the information is (1) REAL, (2) REAL/IMAGINARY, or (3) MAGNITUDE/PHASE. If the data is REAL/IMAGINARY, this flag is incorrectly set to 1. Avoidance: There is no avoidance.

Known Error

CR 38055

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Parallel Processing - DMP - Incorrect SPCforces for constrained & loaded points In a distributed memory parallel execution, dmp>1, SPCforces are incorrect for constrained and loaded interior DOFs. Avoidance: Insert the following DMAP alter:

Description

compile disph1b alter 'pss' call dbstore pss,,,,//0/0/' '/0 $ compile sedisp alter 'kfs,uox,pss'(,-1) call dbfetch /pss,,,,/0/0/0/0/0 $ endalter

Known Error

CR 38056

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Beam Library - PBARL - ILLEGAL INPUT TO SUBROUTINE DOMPFTN When the generalized PBARL is designed using the beam library server, the job fails in DOPR1 with the following message: "ILLEGAL INPUT TO SUBROUTINE DOMPFTN". This message is caused by designing the sixth property (FE) in the EPT table which is currently not used. Avoidance: In the bsbrid subroutine, change the

Known Error

CR 38056 Do 110 i = 1,nprop do 100 j = 1,ndim sentyp(i,j)=3 100 continue 110 continue to Do 110 i = 1,nprop if ( iprop .eq. 6 ) go to 110 do 100 j = 1,ndim sentyp(i,j)=3 100 continue 110 continue

Known Error

CR 38061

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

SSSALTERS - cygyroa.vxx, TEMP(LOAD) - SFM 3003 (EMG) The following message will occur in with the SSSALTER CYGYROA if thermal loads are used. SYSTEM FATAL MESSAGE 3003 (EMG) ATTEMPT TO READ PAST THE END OF A LOGICAL RECORD IN DATA BLOCK ETT (FILE 107) IN SUBROUTINE EMGTAB

Description

The error occurs when the differential stiffness matrix is being generated, and hence the actual output (e.g. displacements, stresses) is correct. However, since differential stiffness is not generated, restarts off this database will not include the desired gyroscopic effects. The error occurs because of the unique way thermal loads are called out in Cyclic solution sequences. The TEMP(LOAD) case control command points to a bulk data LOADCYN entry which inturn points to a temperature set. The EMG module issues the fatal error because it is searching for

Known Error

CR 38062

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Cyclic Symmetry - differential stiffness, modes, tempi - UFM 4342, SFM 3001

Description

In a cyclic symmetry run that uses the differential stiffness (e.g., buckling

Known Error

CR 38062 and normal modes with preload), the applied loads must be uniform. To enforce this requirement, the loads must be applied to segment one only. If loads are applied to segments other than one, then the job will fail with following error messages: *** USER FATAL MESSAGE 4342 (CY1BLD) THE LOAD BULK DATA CARD GIVEN BELOW IS INCONSISTENT WITH SPECIFIED ANALYSIS HARMONICS OR SEGMENTS OR SYMMETRY TYPE. LOADCYN xxxx yyy zzz To avoid this message, remove loads from segments greater than one. Furthermore, if the preload consists of thermal loads, then the job will fail with the following error messages: *** SYSTEM FATAL MESSAGE 3001 (CYCLIC4) THE INPUT

Known Error

CR 38070

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Parallel Processing - DMP - System error message at completion of job DMP jobs may report the following error text at job completion: ERROR 0031-636 User requested child or EOF termination of pm_command

Description

This message does not affect the MSC.Nastran job. Avoidance: Delete the following line from /bin/nast707.dmp: %MSC_ARCH=aix:%export MP_NEWJOB=yes

Known Error

CR 38073

Product

MSC / MD Nastran

Corrected Version GL Abstract

Cyclic Symmetry - RESTART, STATSUB - Inefficient Restart

Description

If a restart from SOL 114 (Cyclic static) into SOL 115 (Cyclic modes) is performed to calculate pre-stressed modes of the model, the static solution will be re-calculated in SOL 115. There is no avoidance.

Known Error

CR 38096

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Miscellaneous - Accounting file, Solution type and CPU time are not written The Version 70.7 accounting program does not properly identify the solution name, CPU, or elapsed times in the account files. Avoidance: Use the following procedure to modify and install a new accounting logging program. 1) Change the current working directory to /msc707/util 2) Change lines 1440 through 1443 in mscact.c from

Description

if( (f04 = fopen( f04f, "r" )) == NULL ) { (void) strcat( f04f, ".f04" ); f04 = fopen( f04f, "r" ); } to (void) strcat( f04f, ".f04" ); f04 = fopen( f04f, "r" ); That is, delete the "if" statement and its matching closing brace. 3) Build a new version of mscact with the command msc707 util mscact 4) Install the new account logger program with the command cp -p mscact ../<

Known Error

CR 38097

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Installation - FLEXlm - /etc/inittab file is wrong. mscsetup for MSC.Nastran Version 70.7 does not set the /etc/inittab line with the full path of the flexlm utility. If the system is subsequently rebooted FLEXlm will not run automatically.

Description Avoidance: If FLEXlm is already installed, and you want the new version of FLEXlm, install it but do not have mscsetup set the /etc/inittab file; if FLEXlm is being installed for the first time, modify the /etc/inittab

Known Error

CR 38097 file after the installation is complete and add the full path for the /bin/flexlm utility.

Known Error

CR 38100

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Installation - No Output When installing MSC.Nastran on Intel computers, the last step in the installation asks if you would like to enter the authorization code. If you choose not to enter the code, the program does not create the authorize.dat file, but the nastxxx.rcf file will incorrectly point to the non-existant file. If you submit a Nastran job, no output files will be created. Avoidance: Either:

Description

1) enter the authorization code when installing. 2) edit the nastxxx.rcf file to remove the "AUTH=" line 3) when you try to run MSC.Nastran, enter the following on either the command line or in the "optional keywords" box pause=yes If you do this, the command window trying to run the program will stay open and you will obtain the error message indicating that the authorize.dat file does not

Known Error

CR 38115

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Description

Installation - Missing library libxlsmp.a[smprt.o] IBM AIX clients that don't have the Fortran compiler installed will be unable to run MSC.Nastran V70.7.0 and V70.7.2 until the libxlsmp.a library is installed on their system or in the /msc707/aix directory. The following message is issued in the log file: MSC/NASTRAN started Mon Jan 03 09:46:03 EST 2000 Could not load program /tmp/vxlq/n707/msc707/aix/analysis Could not load library libxlsmp.a[smprt.o] Error was: No such file or directory

Known Error

CR 38115 Avoidance: Install the missing library.

Known Error

CR 38116

Product

MSC / MD Nastran

Corrected Version Abstract

Superelements - CSUPER, PARAM,INREL - SFM 5423 (DMPYAD) If SOL 101 with inertia relief is used with external superelements, the external superelement data recovery run will fail with: *** SYSTEM FATAL MESSAGE 5423 (DMPYAD) ATTEMPT TO MULTIPLY INCOMPATIBLE MATRICES

Description

indicating that UOO and CRX are not correct. This is due to an error which results in CRX not being written to the EXTDRUNT. Avoidance: Include the following DMAP alter in the residual structure run: compile super3 alter 339 dbview crx0=crx (where seid=0 and wildcard) $ equivx crx0/ol1m/-1 $

Known Error

CR 38119

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Postprocessing - SOL 105, PARAM,POST,0 - Missing Output Under PARAM,POST,0 in SOL 105, the buckling eigenvalues and eigenvectors will not be available in MSC.Patran. Avoidance: Use PARAM,POST,-1 or insert the following DMAP alter:

Description

compile super3 alter 'CASEdr,ol2s'(,-1) app=app1 $ alter 'CASEdr,ol2s' app='reig' endalter Verified , see attachs for files. Chanhed 'reported by to ABBEY as LIBBY no longer with MSC

Known Error

CR 38123

Product

MSC / MD Nastran

Known Error

CR 38123

Corrected Version 2001 Abstract

Optimization/Design Sensitivity - DEQATN, DRESP2 - Wrong Answers If multiple DRESP2's refer to the same DEQATN, only the first (lowest numbered DRESP2 is checked to see if the number of DRESP2 arguments agrees with the number DEQATN arguments. If a subsequent DRESP2 has a mismatch with the number of arguments, the error goes undetected and unpredictable answers are produced.

Description Avoidance: There is no avoidance other than not sharing a DEQATN id on multiple DRESP2's. If this is too tedious, the user must be vigilant in checking that the number of arguments on the DRESP2 agree with the number of arguments on the left hand side of the DEQATN in every DRESP2 except the lowest numbered one. Known Error

CR 38127

Product

MSC / MD Nastran

Corrected Version 2001 Optimization/Design Sensitivity - DRESP2, DSAPRT - Incorrect Sensitivity Data

Abstract

When the formatted prints of sensitivity data (case control command DSAPRT) for DRESP2 responses list a frequency value of the response, the value has been incorrectly scaled upward by a factor of ten. A similar error exists for time values. Also, values that are greater than 100. appear as *******. Description

Avoidance: Frequency/time values for DRESP1 responses are printed correctly. The user must be aware that printed DRESP2 frequency/time values are 10 times greater than they should be. It should also be noted that when a DRESP2 response spans several frequency, only the lowest frequency is printed.

Known Error

CR 38137

Product

MSC / MD Nastran

Corrected R2001 Version Abstract

SSSALTERs - errors in alter1ga.vxx and alter9ga.vxx

Known Error

Descriptio n

CR 38137 SSSALTERs alter1ga.vxx an dalter9ga.vxx have errors in them when using OTM (Output Transformation Matrices) with OUTPUT2 or in frequency response. alter1ga.vxx does not correctly write the tables identifying the terms in the OTM if OUTPUT2 is used. alter9ga.vxx does not correctly use the OTM if it is used in frequency response. Avoidance: Contact MSC and request an updated version of the alters or get them from the MSC web page at: http://www.mechsolutions.com/support/prod_support/nastran/sssalters/index.ht ml

Known Error

CR 38141

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Miscellaneous - OUTPUT2, Year 2000 - Incorrect Year Printout When running nastran jobs in year 2000+, on some unix machines, the output2 trailer information will print out the date incorrectly. For example, when using param,post,,-1, the trailer information for OEF1 coming out right after UIM 4114 with a job ran on January 6, 2000 will appear as follows: 1001 63 1 6 100 0 1

Description

instead of the correct value 1001 63 1 6 0 0 1 In this case field 5 is the year. This problem is fixed in Version 70.7

Avoidance: There is no avoidance. Note that the results are not affected by the date printout. Known Error

CR 38143

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - SYSTEM(173) - Old QUAD4 Formulation

Description

SYSTEM(173) allows the selection of either the pre-V68 QUAD4 formulation or the V68-V70.5 formulation. This system cell is incorrectly documented in the Version 70.7 Release Guide. The documentation should state: 1: Requests pre V68 QUAD4 Formulation

Known Error

CR 38143 2: Requests V68-V70.5 QUAD4 Formulation Likewise the Version 70.7 Release Guide documentation for the keyword OLDQ4K incorrectly states that this keyword is equivalent to setting SYSTEM(173)=2, the keyword is equivalent to setting SYSTEM(173)=1.

Known Error

CR 38167

Product

MSC / MD Nastran

Corrected Version GL Abstract

Installation - nastran command: fails with multiple 70.7.X versions If V70.7.2 of MSC.Nastran is installed in the same directory as V70.7.0, then both cannot run. The intent was to allow users to use "nast7070" for V70.7.0 and "nast707" or "nast7072" for V70.7.2. This feature was broken in the V70.7.x releases. Avoidances: 1. Install V70.7.2 in a directory with a different MSC_BASE than V70.7.0 2. Use V70.7.2 and not V70.7.0

Description

Details: Nastran can not have seperate versions installed in directories like: /msc/md200700/linux /msc/md200701/linux /msc/md200702/linux Rather, the whole tree needs to be under the version. Ie: /msc/md200700/msc2007/linux /msc/md200701/msc2007/linux /msc/md200702/msc2007/linux The /msc/bin/nast* files will need to have links made to /msc/VERSION/msc2007/bin/nast2007

Known Error

CR 38168

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Superelements - Incorrect OUTPUT2 units for different SEs w/ PARAM OUNIT2

Description

If PART superelments are used, and different values are provided for

Known Error

CR 38168 PARAM,OUNIT2 in different PARTs, the program will use these values incorrectly.

1) Setting distinct PARAM, OUNIT2 values in each of the Partitioned Bulk Data Sections is ignored - only the setting for the residual structure is used and the OUNIT2 values set under the BEGIN SUPER=xxx are ignored. 2) Setting distinct PARAM, OUNIT2 values PER SUBCASE using expanded Case Control causes: A) All geometry for all SE to be written to the 1st OUNIT2 specified B) End of Data record on that 1st OUNIT2 C) Results for the residual are then written to that 1st OUNIT2 file D) The 1st OUNIT2 file is rewound and re-labeled (wiping out the geometry and SE0 results) and the correct SE results are written. E) L Known Error

CR 38180

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Frequency Response - DMP>1, SOL 108, fluid-structure decks - Wrong answers If distributed memory parallel, dmp>1, is used with a fluid-structure in SOL 108, then wrong answers result. Avoidance: Insert the following DMAP alter:

Description

compile freqrs alter '197','' if ( acsyml and adjflg1 and GETSYS(np,197)>0 and soltyp='modal') ) then $ endalter

Known Error

CR 38195

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Plotting - .plt File Contains Bad Date String

Description

The plot file will contain an invalid date string on any file generated after Dec 31, 1999. The error is present in all versions of MSC.Nastran, up to and including V70.7.2. On Version 70.7 the year 2000 was written

Known Error

CR 38195 simple as "0", for example 1-10-0; however other strings are possible.

This error does not cause any other problems with the plot data. Avoidance: There is no known avoidance. Known Error

CR 38207

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Design Sensitivity/Optimization - Static Aero, METHOD - UFM 1126 for M1RR If the Case Control for a multi-subcase static aeroelastic solution in SOL 200 contains a METHOD command that varies from subcase to subcase, a FATAL error can occur in which the M1RR matrix is recomputed. Since the M1RR matrix is not declared OVRWRT, this causes UFM 1126 shown below. The error occurs when the METHOD command is the ONLY boundary difference between the two sets of subcases.

Description

*** USER FATAL MESSAGE 1126 (GNFIST) DMAP MODULE MPYAD IS ATTEMPTING TO OUTPUT DATABLOCK 201 NAME = M1RR , WHICH ALREADY EXISTS. USER ACTION: DELETE THE DATABLOCK, OR USE FILE M1RR=OVRWRT 0FATAL ERROR Avoidance: Since static aero analysis in SOL 200 is not affected by METHOD selection, remove the extraneous METHOD selection(s) from the Case Control or insert the follo

Known Error

CR 38221

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - PSHELL, MAT2 - Missing Stress Output for Plate Elements

Description

When a plate element references a MAT2 entry with an MID larger than 99999999, it is assumed that this MAT2 entry has automatically been created from a PCOMP entry (see QRG, MAT2 entry, Remark 13). Thus, stress output will be missing unless PARAM, NOCOMPS, -1 is specified. Avoidance: Do not use MIDs of MAT2 entries larger than 99999999, or use PARAM, NOCOMPS, -1.

Known Error

CR 38237

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Documentation - slaveout=yes, mergeresults=no - Clarify Documentation for DMP Distributed Memory Parallel executions may specify the keywords slaveout and mergeresults on the submittal line. These keywords are documented in the V70.7 Release Guide. The Release Guide should have clarified and emphasized that the non-default values of these keywords, slaveout=yes and mergeresults=no are typically only used for debug purposes. The following should also be noted: 1. If mergeresults=no is specified in a static run the results of the individual domains will not be sent back to the master and the system solution will not be obtained. 2. The keyword mergeresults has no affect on a solution 103 or 111 run. 3. In solution 108, if mergeresults=no is specified and slaveout=yes is not specified, then the results of the slave processors will be lost. 4. In solution

Known Error

CR 38238

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Cyclic Symmetry - SFM 3001 (READ), Poor Message In SOL 115, if the stiffness and mass matrix have common null-columns the following message will be issued:

Description

*** SYSTEM FATAL MESSAGE 3001 (READ) THE INPUT DATA BLOCK IN POSITION 13 DOES NOT EXIST. Avoidance: Make sure degrees of freedom with no stiffness and no mass are constrained. In Version 70.7 parameter AUTOSPC will do this, but in Version 70.5 AUTOSPC would not correctly constrain grids on CYJOIN entries. A better error message is implemented in Version 2001..

Known Error

CR 38254

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Optimization/Design Sensitivity - PBAR - UFM 5626 (DSAD17)

Description

Optimization analysis does not support item codes 18 and 19 for PBAR for complex stress. If specified the following fatal message is issued:

Known Error

CR 38254 *** USER FATAL MESSAGE 5626 (DSAD17) ITEM CODE 18 REFERENCED ON DRESP1 ENTRY 16 WITH RTYPE = FRSTRE IS INVALID FOR ELEMENT TYPE BAR 34. USER ACTION: CHECK THE SPECIFIED ITEM CODE WITH THOSE LISTED IN APPENDIX A OF THE MSC/NASTRAN QUICK REFERENCE GUIDE. Avoidance: There is no avoidance.

Known Error

CR 38257

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

DMAP - FBS - Wrong Answers, BIOMSG: ERROR 31 The FBS module may return poor fatal diagnostics (BIOMSG: ERROR 31) or wrong answers when a left hand fbs is requested incorrectly. An example of a left hand fbs follows. The conventional (right hand) equation solved by the FBS module is: Given the square matrix A, and a collection of vectors X, find B, where A*X< = B $ FBS module A is first decomposed into its factors L and U. $ DECOMP OR DCMP modules.

Description Typically, X and B have many fewer columns than A. There are applications where X has many more rows than A. That type of problem is most naturally posed as X*A8GB) may cause failure of nastran command Machines with physical memory in excess of 8GB may cause the nastran command to fail with a message similar to:

Description

MSC/NASTRAN V70.7 (SUN SPARC SunOS 5.7) Wed Jan 26 14:23:19 2000 *** SYSTEM INFORMATION MESSAGE (pgm: nast707, fn: validate_buffsize_memory) Assuming "memory=-2147483648" as specified by

Known Error

CR 38337 "memorymaximum=0.8*physical". In some instances, an error will not occur, instead the nastran command may generate an incorrect memory request. Avoidance: Set the maximum memory size in a system RC file to the value listed in the "MSC.Nastran V70.7 Configuration and Operations Guide", Table 4-2, pg 90. For example, on Solaris: memorymaximum=4GB

Known Error

CR 38349

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

P-Elements - UFM 9050 DCMP (70.5) or UFM 3001 VECRMA (70.7) It is possible that in a model containing both p- and h-elements that the run may fail with either UFM 9050 or UFM 3001.

Description

Avoidance: This problem is under investigation. The model demonstrating this problem executed successfully when more memory was allocated or the BUFFSIZE was increased.

Known Error

CR 38365

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Elements - PARAM,SNORM - Wrong Answers

Description

The maximum allowed value of the SNORM parameter is 45 degrees. Higer values are automatically set lower. For shells meeting at a large angle, such as a right angle, with a different number of elements on each side, the calculated normal may be greater than 45 degrees from one side. This is legitimate, but will fail the error check.

Known Error

CR 38373

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Rigid Elements and Multipoint Constraint - RBEi, MPC - UFM 5289

Description

If a dof is listed as depednt more than once on an MPC or RBEi entry, Nastran will issue UFM 5289, indicating an error. Unfortunately, the message may point to the wrong dof and may not point to the entry which has the error.

Known Error

CR 38373 Avoidance: There is no avoidance other than inspecting the MPC and rigid element entries.

Known Error

CR 38376

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Static Analysis - DMP>1, GPSTRESS and PARAM,POST,0 - Missing output in xdb If grid point stresses are requested with dmp>1 and param,post,0 then the xdb file will be missing the grid point stresses for the slave domains. Avoidance: Insert the following DMAP alter:

Description

compile sedrcvr alter 'GPLS,EGPSTR'(2),'' DBC OPG1,OUGV1,OEF1X,OES1X,OQG1,GPL,EGPSTR,EGPSF,GPDCT, ELDCT,error1,,,,,,,,,// 'OPG'/'OUG'/'OEF'/'OES'/'OQG'/'GPL'/'GPS'/'SVF'/ 'GPDCT'/'ELDCT'/'perror'////////// -1/DBCPATH/S,N,CP/APP1/ICYCLIC/GEOMU/LOADU/POSTU/ DBCDIAG/DBCCONV/DBCOVWRT/DESCYCLE/////adptindx/lusets $ endalter

Known Error

CR 38378

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

DMAP - MATMOD option 12 - Wrong answers, Missing Fatal Message If the first input, I1, to the MATMOD module, under option 12, is purged then the module will incorrectly report that NONULL=0 and the O1 output is purged without warning or fatal even if the second and third inputs (I2 and I3) are not purged and contain null columns. The documentation for MATMOD option 12 contained in the "DMAP Module and Data Blocks" guide states that only I2 and I3 may be purged, which implies that a fatal message should be issued if I1 is purged. Avoidance: Rearrange the inputs so that the first input is not purged.

Known Error

CR 38381

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Optimization/Design Sensitivity - DRESP1 - UFM 6482 from DOPR3R

Known Error

CR 38381

Description

USER FATAL MESSAGE 6482 indicates that an invoked DRESP1 entry in a SOL 200 subcase is not compatible with the ANALYSIS type for that subcase. Although the message points to a real user input error, it is possible that the identified DRESP1 type is not the type that caused the error. Avoidance: The UFM has the correct RID for the DRESP1. Use the RID and not the response type to identify the incorrect input.

Known Error

CR 38396

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Superelements - NASTRAN LOCBULK=2 - SFM 4192, SFM 3062 in SEMA If the multi-master method is used on a Cray and LOCBULK is set to 2 and there are GRID id's greater than 1000000 (one million) then the run may fail with SFM 4192, indicating undefined grid points. *** SYSTEM FATAL MESSAGE 4192 (SEMA) GRID POINT .... IN SUPERELEMENT 0 IS NOT DEFINED IN BGPDT FOR DOWNSTREAM SUPERELEMENT and 0*** SYSTEM FATAL MESSAGE 3062 MODULE = SEMA FAILURE OCCURRED IN UTILITY MAPBTI CALLED IN SUBROUTINE SEMA . REQUESTED EXTERNAL ID(S) NOT FOUND.

Description Avioidance: There are several avoidances: 1. Insert the following DMAP alter in the residual structure run: compile phase0 alter ',np,' paraml bgpdt//'trai'/6/s,n,maxgid//s,n,nobgpdt $ if ( nobgpdt>-1 ) putsys(maxgid,186) $ endalter 2. Reduce all GRID id's to less than one million. 3. Run using a different computer type, or run using LOCBULK=1 Known Error

CR 38398

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Optimization/Design Sensitivity - DSAPRT, DRESP1 - SFM 4276

Known Error

CR 38398

Description

If the fomatted sensitivity option is used and there are no retained responses associated with DRESP1 entries, but there are retained DRESP2 responses, SYSTEM FATAL MESSAGE 4276 and a traceback in dsaprt is produced. Avoidance: Use the unformatted sensitivity option or force the retention of a DRESP1 response.

Known Error

CR 38401

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Restarts - Superelements - Changes in SPCs may yield Wrong answers If in a superelement restart run, changes are made to the constraints (spcs) of only one superelment, then wrong answers may result. Avoidance: Insert the following DMAP alter:

Description

compile phase0 alter 'IF ( LRESTART )'(2)' IF (KCHNG) CALL CHNGFLG //KCHNG/SEDWN/SEID/PEID $ IF (MCHNG) CALL CHNGFLG //MCHNG/SEDWN/SEID/PEID $ IF (BCHNG) CALL CHNGFLG //BCHNG/SEDWN/SEID/PEID $ IF (PCHNG) CALL CHNGFLG //PCHNG/SEDWN/SEID/PEID $ IF (K4CHNG) CALL CHNGFLG //K4CHNG/SEDWN/SEID/PEID $ endalter

Known Error

CR 38411

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Optimization/Design Sensitivity - DVPREL2, APRCOD, DOM9 - SFM 4276, EC1404 If an input file for optimization has DVPREL2 entries and APRCOD is set to 3 on the DOPTPRM entry, the run may fail and issue SYSTEM FATAL MESSAGE 4276 ERROR CODE 1404 in the DOM9 module. .

Description

Avoidance: 1) If the file contains DVPREL2 entries, do not set APRCOD to 3 or 2) If the deck contains DVPREL1 entries, force them to be retained using a DSCREEN entry.

Known Error

CR 38412

Product

MSC / MD Nastran

Known Error

CR 38412

Corrected Version GL Abstract

Submittal - "pwd: cannot access parent directories" error Under not-fully-understood circumstances a small subset of C shell users may encounter the following error message:

Description

$ /nast/deliv/msc707/unix/bin/msc707 /nast/deliv/msc707/unix/bin/msc707[42]: pwd: cannot access parent directories /nast/deliv/msc707/unix/bin/msc707[97]: cd: bad argument count when submitting a nastran job. Avoidance: One avoidance is to use the Korn shell (ksh) as the login shell.

Known Error

CR 38428

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

Aeroelastic Analysis - PAERO4, AEFACT - UFM 6171 (APD4) If a PAERO4 entry has fewer strips that requested, the program will issue USER FATAL MESSAGE 6171 (APD4) and terminate. Unfortunately, the fatal message will incorrectly state that the error is on an AEFACT entry with the same id as the PAERO4. Avoidance: Provide the correct number of strips on the PAERO4 entry.

Known Error

CR 38443

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - DEQATN - Unexpected Results The documentation for the DEQATN entry does not mention that the arithmetic is carried out using the type of the input data. For example, if a term is raised to a fractional power:

Description

X=A**(1/2) since both values in the exponent are integers, the value returned for the exponent is calculated using integer arithmetic or 1/2=0. Avoidance: Excersize caution when writing equations. If possible, avoid integer terms.

Known Error

CR 38449

Known Error

CR 38449

Product

MSC / MD Nastran

Corrected Version 2001 Abstract Description

GPFORCE - MPCFORCE, TEMP(LOAD) - Missing APP-LOAD Output If there are thermal loads and mpcforces, GPFORCE output may be missing the applied load (APP-LOAD) output. Avoidance: There is no avoidance.

Known Error

CR 38455

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - Configuration & Operations Guide - Maximum Memory on HP-UX Tables 4-2 and C-7 of the "Configuration and Operations Guide" incorrectly state the maximum memory size on HP-UX systems is 2 GB. The maximum memory size on HP-UX systems is:

Description

1 GB (256 MW) on HP-UX 10.20 2 GB (512 MW) on HP-UX 11.00, PA-RISC 2.0 The actual value usable by the "memory" keyword is reduced from this by approximately 35 MB.

Known Error

CR 38458

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

Nonlinear Analysis - QUAD4 - Plastic In-Plane Bending, Wrong Answers If a nonlinear analysis is performed with QUAD4 elements with elastic, perfectly plastic material and the elements are loaded in pure shear and twise (no bending, no axial load), then the results may incorrectly indicate that the model can sustain increasing loads even after the elements in the critical load path have reached the inplane shear plastic limit. This problem only occurs for coarse meshes subjected to pure shear loads. It is not likely to affect real world models.

Known Error

CR 38468

Product

MSC / MD Nastran

Corrected Version 70.7.3

Known Error

CR 38468

Abstract

Miscellaneous - GP4, Possibly Other Modules - Infinite Runtime Sort routines in nastran have an upper limit that may be exceeded if models have many of one type of element. The deck that encountered this error had several hundred thousand rigid elements.

Description Avoidance: There is no avoidance. The limit has been removed in MSC.Nastran V2001. Known Error

CR 38478

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation/QRG - CONNECT, PBARL, PBEAML - Non-Existant Developer's Guide The MSC/NASTRAN Quick Reference Guide documentation for the FMS CONNECT statement, remarks : 5. Custom beam cross-section evaluator libraries developed by users should comply with the MSC/NASTRAN Beam Cross-section Evaluator Developer's Guide.

Description

There is no such document. Avoidance: The remark should instead, refer to: MSC/NASTRAN V69 Release Guide, Section 3.1 Beam Cross-Section Library Appendix C: Adding Your Own Beam Cross Section Library

Known Error

CR 38501

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Optimization/Design Sensitivity - Flutter, Superelements - UFM 1126 for FPHP USER FATAL MESSAGE 1126 occurs if a flutter analysis is attempted with superelements in SOL 200 and complex eigenvector output is requested. See also CSR 37130.

Description

Avoidance: Remove the eigenvector request or make the following dmap changes: compile fea alter 1 type db fphp

Known Error

CR 38501 endalter

Known Error

CR 38502

Product

MSC / MD Nastran

Corrected Version Abstract

Optimiztion/Design Sensitivity - DEQATN - SFM 233 (PRSPOP) In SOL 200, if the DEQATN bulk data entry uses certain keywords such as "OR" as variable names in the equation argument list, an error message similar to the following will occur:

Description

*** SYSTEM FATAL MESSAGE 233 (PRSPOP) UNDERFLOW OCCURRED DURING PROCESSING OF OPERAND STACK DURING DEQATN EQUATION PROCESSING. PROGRAMMER INFORMATION: STACK POINTER = 0 WITH MINIMUM = 1 *** COMPILATION DIAGNOSTIC INFORMATION *** 1. STATEMENT TYPE: DEQATN EQUATION 2. EQUATION ID NUMBER: 14 3. EQUATION: TWALL(OR,IR)=OR-IR *** SYSTEM FATAL MESSAGE 233 (PRSPOP) The error message needs to be improved to add the following: Possible cause: variable name is a keyword such as "OR". Avoidance: Change the variable name

Known Error

CR 38519

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation/QRG - PACABS - Units

Description

The Quick Reference Guide description for the PACABS entry should state that the units of the B, K, and M fields are per unit area.

Known Error

CR 38539

Product

MSC / MD Nastran

Corrected Version 2001 Abstract Description

Distributed Memory Parallel - DMP, DISDCMP - Infinite CPU Loop MSC.Nastran may get caught in an infinite cpu loop when distributed memory parallel is used with inertia relief.

Known Error

CR 38539 Avoidance: Do not use ineria relief with distributed memory parallel in V70.7.

Known Error

CR 38542

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Miscellaneous - VECPLOT - SWM 3062, Insufficient Memory Module VECPLOT does not check for insufficient memory. This may lead to the following unclear message:

Description

0*** SYSTEM WARNING MESSAGE 3062 MODULE = VECPLOT FAILURE OCCURRED IN UTILITY GTXYZD CALLED IN SUBROUTINE DMTRXD . PREXYZ FLAG ARGUMENT WAS SET WITH AN INCORRECT VALUE TO GET THE REQUESTED DATA RETRIEVAL. *** USER WARNING MESSAGE 3199 (VECPLOT) NON-FATAL MESSAGES MAY HAVE BEEN LOST BY ATTEMPTING TO QUEUE MORE THAN 100 MESSAGES.

Known Error

CR 38547

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Aeroelastic Anaysis - Multiple Double Lattice Groups yield Wrong Answers If a doublet lattice model (CAERO1 and/or CAERO2) is created in SOL 144 for use in static aeroelasticity, and the model has more than one interference group, the downwashes representing unit perturbations of the control devices (the DJX matrix) are incorrect under most circumstances. The problem is caused due to the erroneous introduction in Version 70.5 of an assumption that the coordinate system ID and the CAEROi ID are in the same order. This is true for a single interference group, but not for multiple groups. As a result, the wrong coordinate system may be used in the computation of the downwash. Avoidance: There is no avoidance other than to convert the model to have a single interference group. Note, also, that unsteady aerodynamics (SOL 145 and SOL 146) are NOT affected.

Known Error

CR 38555

Known Error

CR 38555

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Installation - NFS Mounted - HP-UX 10.2 and 11.0 The original MSC.Nastran V70.7 (r1) CD may fail to install correctly on some HP-UX 10.20 and 11.00 systems if the installation base directory is NFS mounted from another system. The problem is due to incorrect information being returned from the df(1) utility, this should be visible from the output of the command df -k

Description Avoidance: Choose one of the following avoidances: 1) Use the MSC.Nastran V70.7.2 (r2) release, that works around the HP-UX utility error. 2) Install on the computer exporting the filesystem. If this is not an HP-UX system, you can use the "Custom" installation to deselect the local computer's binaries and select the HP-UX binaries. Known Error

CR 38559

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Optimization/Design Sensitivity - DSAD, DRESP2 - SFM 3007 An optimization job may fail in module DSAD with SFM 3007 when the following conditions are met:

Description

1. The DRESP2 entry only references the DNODE term, 2. The job has more than one subcases, 3. The DESGLB entry references the DRESP2 entry with DNODE terms.

The avoidance is to replace DESGLB with the DESSUB entry and place it in the last subcase. Known Error

CR 38564

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Documentation - Linux: how to enable large files (> 2 GB)

Description

The "Configuration and Operations Guide" incorrectly states that large files are available on Linux. They were not in the version of either the Linux

Known Error

CR 38564 kernel (2.0.36) or libc (2.0) that MSC.Nastran was built with. Note: The support required for this was not built into MSC.Nastran, so using a system with support for large files will not help. Large file support will be available in a new release of MSC.Nastran Version 70.7.2 on Linux that is to have a build date and release date of June 2000. Avoidance: Use INIT and ASSIGN statements to specify multiple physical files for any DBSet that exceeds 2GB.

Known Error

CR 38574

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Optimization/Design Sensitivity - DISPRS - Poor Performance It is possible, when performing modal frequency analysis in SOL 200, to recover results to the g-set in the DISPRS subDMAP twice with each call performing identical operations. For large problems, this can entail significant CPU resources with no benefit.

Description

Avoidance: The following dmap alter removes the redundant call: compile fea alter 'if ( psldf'(2) if (delta) then $ alter 'if (psldf'(2,4) endif $ endalter

Known Error

CR 38595

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Composites - PCOMP, PARAM,S1 PARAM,POST,0 - Wrong Answers in xdb If stresses are to be sorted (PARAM,S1) and composite stresses are requested, then the xdb file will contain incorrect composite stresses.

Description

Avoidance: Insert the following DMAP alter: compile sedrcvr alter 'DBC OES1C','' DBC ES1C,,,,,,,,,,,,,,,,,,,// 'OESC'////////////////////

Known Error

CR 38595 -1/DBCPATH/S,N,CP/APP1/ICYCLIC/GEOMU/LOADU/POSTU/ DBCDIAG/DBCCONV/DBCOVWRT/DESCYCLE/////adptindx $ endalter

Known Error

CR 38608

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation/QRG - FLFACT - Remark 4 contains incorrect equation The formula of Remark 4 on the FLFACT bulk data entry of the Quick Reference Guide V70.5 has two omissions and a typographical error. It should read as follows:

Description

F1 (FNF-FMID) (NF-i) + FNF (FNF-F1) (i-1) Fi = ----------------------------------------------------------------------(FNF-FMD) (NF-i) + (FMID-F1) (i-1) The above formual was taken from the Aeroelastic Supplement and was compared to output generated by Version 70.5.

Known Error

CR 38610

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation/QRG - EIGRL - System Cell 229 Documentation Incorrect

Description

The documentation for SYSTEM cell 229 incorrectly indicates that if it is given a value of 1, then the scratch database usage for Lanczos will be decreased. This system cell applied only to the old Lanczos solver and will not have an impact on the current Lanczos solver in MSC.Nastran Version 70.7 (The old Lanczos solver is available by setting SYSTEM(273)=1).

Known Error

CR 38614

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Nonlinear Analysis - PARAM NMLOOP may give poor answers

Description

Nonlinear SOL 106 with PARAM NMLOOP may give poor answers. The eigenvalues, displacements, and stresses for modes including prestresses and nonlinear geometry may be based upon matrices that do not reflect a converged solution. This error started in version 70.7 when a different version of the history

Known Error

CR 38614 file was used to construct the required matrices. The use of NLPARM method ITER-1 gives fairly good results. Avoidance: An avoidance ALTER is available from MSC to improve results. When using HEXA elements in nonlinear, include NASTRAN SYSTEM(309)=1 , see CSR 38899.

Known Error

CR 38620

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Superelements - DMIG - UFM 327 DMIG matrices in part superelements result in the following fatal message *** USER FATAL MESSAGE 327 (IFS2P) BAD DATA OR FORMAT OR NON-UNIQUE NAME. DMIG also for DMI

Description

The message above occurs when two part superelements adjacent in the processing order have dmigs or dmis with the same name. Avoidance: Add a second dmig or dmi matrix. It does not need to be used anywhere, it is only necessary to have more than one dmig or dmi name.

Known Error

CR 38627

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Subcases - SPC, DEFORM - UFM 9058 In static analysis, if DEFORM and SPC entries are changed between subcases the job will fail with the message:

Description

USER FATAL MESSAGE 9058 (SUPER3) - THE SOLUTION FOR THE RESIDUAL STRUCTURE DOES NOT EXIST Avoidance: Execute the subcases as two separate runs.

Known Error

CR 38629

Product

MSC / MD Nastran

Corrected Version Abstract

Nonlinear Analysis - TEMP(LOAD), PARAM,LGDISP - Incorrect OLOAD Output

Description

MSC.Nastran considers the fictitious forces for thermal expansion to be loads. These are output by a case control command OLOAD. The output is

Known Error

CR 38629 for the initial geometry, even when geometric nonlinear effects are requested. Since only the OLOAD output is wrong, other items like displacements, element forces and SPCFORCEs are not affected. Other load types (like PLOAD and FORCE1) are correctly updated to the new geometry.

Known Error

CR 38632

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Acoustics Analysis - KJJZ of fluid is wrong for prestressed structure An acoustic analysis of a prestressed structure yields an incorrect fluid part of KJJZ. The values are off by a factor of 2. Avoidance: Apply the following dmap alter to Version 70.5 or 70.7:

Description compile semg alter 'add5','add5' add5 kjjl,kjjnl,kdjjnl,,/kjjz $ endalter Known Error

CR 38634

Product

MSC / MD Nastran

Corrected Version 2001 Abstract Description

SSSALTERs - trncompa.v707, SORT1 - Missing Output If sort1 output is requested while using the trncompa sssalter, no ply output will be obtained. Avoidance: Only request sort2 output.

Known Error

CR 38645

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Description

Plotting - XYPLOT - Missing Data Points An XYPLOT of grid points versus temperature results in a heat transfer analysis results in missing data points. Avoidance: There is no avoidance.

Known Error

CR 38653

Known Error

CR 38653

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Mass Matrix - SYSTEM(303), CUTOFF - UFM 17(LOOKUP) The MSC.Nastran Version 70.7 Release Guide states that the name for SYSTEM(303) is CUTOFF. If SYSTEM CUTOFF=1 is specified, the program will issue: USER FATAL MESSAGE 17 (LOOKUP) SYMBOL "CUTOFF" IS UNDEFINED Avoidance: Use the system cell number rather than the name.

Known Error

CR 38654

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Superelements/Nonlinear Analysis - PARAM,POST,0 - SWM 6065 (DBC) If superelements are used in SOL 106 and PARAM,POST,0 is used, it is possible that SWM 6065 may be issued, followed by SWM 6066, indicating that the DBC module has been terminated. If this occurs, no additional information will be written to the .xdb file for post-processing.

Description

Avoidance: Insert the following DMAP alter into the file: compile super3 $ remove ol2s from DBC list alter 'dbc.*casedr.*ol2s.*casecc.*oltype','' DBC CASEDR,,,,,,,,,,,,,,,,,,,// 'CASECC'//////////////////// -1/DBCPATH/S,N,CP/APP/ICYCLIC/GEOMU/LOADU/POSTU/ DBCDIAG/DBCCONV/DBCOVWRT/DESCYCLE/////ADPTINDX $

Known Error

CR 38676

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract

Description

Acoustic Analysis - Missing Panel Participation Factor Output Prior to Version 70.7.2 fluid/structure problems that have no s-set (no constraints) will not allow panel participation factors to be printed with PARAM,FLUIDMP or STRUCTMP. Avoidance: Use AUTOSPC and an unattached GRID to force a degree of freedom

Known Error

CR 38676 in the s-set.

Known Error

CR 38682

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Nonlinear Analysis - NMLOOP - Possible Wrong Answers The use of NMLOOP yields incorrect prestressed modes in Version 70.7 if the user does not enforce a stiffness update. The prestressed modes are correct in Version 70.5 because the stiffness is updated automatically at the end of the subcase. Avoidance: There are three possible avoidances in V70.7, we recommend the first option. 1. Insert the following dmap alter:

Description

ECHOOFF $ SWITCH ESTNL, REPLACE MODULE EMAKFR WITH SUBDMAP CENTRIP COMPILE NLSTATIC $ VER 70.7 BY R.L.H. MARCH 29, 2000 ALTER 'NMLOOP.*CNMLOOP=2','' $ IF ( NEWP>-1 AND NMLOOP0 ) THEN CNMLOOP=2 $ MESSAGE //' DELETE/COPY ESTNL $ CSR 38614' DELETE /MESTNL,,,, $ COPY ESTNLH/MESTNL $ ENDIF COMPILE NLKR $ ALTER 'EMAKFR','' $ TYPE DB,EQEXINS $ CAL

Known Error

CR 38684

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - PSHELL - Remark 14, (ts)10e8(ts) incorrect. Remark 14 under the PSHELL description in the MSC/NASTRAN Verson 70 and 70.5 Quick Reference Guide description is incorrect.

Description It says: 14. If MIDi is greater than or equal to (Ts)10^8(Ts), then parameter

Known Error

CR 38684 NOCOMPS is set to +1 indicating that composite stress data recovery is desired. (MIDi greater than (Ts)10^8(Ts) are generated by PCOMP entries.) It should say: 14. If MIDi is greater than or equal to 10^8, then parameter NOCOMPS is set to +1 indicating that composite stress data recovery is desired. (MIDi greater than 10^8 are generated by PCOMP entries.) The v70.5 online encyclopedia has the correct remark as does pre v70.0 Quick Reference Guides.

Known Error

CR 38722

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Optimization/Design Sensitivity - PCOMP - UFM 315, UFM 316 In Version 70.7 it is possible to output updated propertied in an optimization run. If a model contains PCOMP entries and one or more of the PCOMP entries has an odd number of layers, then any subsequent run using the updated PCOMP entries generated from the previous puch file will fail with the following error messages:

Description

*** USER FATAL MESSAGE 315 (IFPDRV) FORMAT ERROR ON BULK DATA ENTRY PCOMP X *** USER FATAL MESSAGE 316 (IFPDRV) ILLEGAL DATA ON BULK DATA ENTRY PCOMP X

Avoidance: Punch out the PCOMP entries using the small field format (e.g., param,despch1,x) where x can be -1, -2, -3, -5 -,6, or -7. The default is param,despch1,6. Known Error

CR 38740

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

DMAP - DRHM3 corrupts OSE1 table

Description

It has been observed that on Version 70.5 SGI systems that the OES1 table

Known Error

CR 38740 produced bythe DRHM3 module is corrupted and can not be printed.

Known Error

CR 38743

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Optimization/Design Sensitivity - SPCFORCE, DSCREEN - UFM 315 Specifying the response type (RTYPE) of SPCFORCE on the DSCREEN entry in SOL 200 will result in UFM 315 ILLEGAL DATA ON BULK DATA ENTRY DSCREEN. Note that the SPCFORCE response type was first added in V70.7.

Description

Avoidance: Create an equivalent DRESP2 for each DRESP1 of type SPCFORCE that will be constrained. Then specify the response type (RTYPE) of EQUA on the DSCREEN entry. Verified in R. 32. -TIN-

Known Error

CR 38750

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Aeroelastic Analysis - RESTARTS, MKAERO - Inefficient Processing The dynamic aeroelastic restarts are dependent on the sorted order of the MKAEROi (i=1 or 2) bulk data entries whenever multiple entries are present. This creates the situation of regenerating the aerodynamic matrices when the /,1,99999 method of deleting and reinputting the bulk data is used. The MKAEROi entries on the restart MUST be in the same order as the coldstart run otherwise SOL 145 or 146 will rerun AMG/DECOMP even though the MKAEROi entries are identical to the coldstart but in a different sorted order.

Aviodance: To avoid this problem the restart should only delete the specific bulkdata entries required NOT the entire bulkdata input. Known Error

CR 38769

Product

MSC / MD Nastran

Corrected Version 2001.0.3 Abstract Description

Materials - CQUAD4, MAT8, G12 - UFM 4297 In Version 70.7, if the G12 field on the MAT8 entry is blank, then the job will fail with the following misleading error messages: *** USER FATAL MESSAGE 4297 (EQD4D)

Known Error

CR 38769 QUAD4 ELEMENT WITH ID = 1 HAS AN INTERIOR ANGLE POSSIBLY GREATER THAN OR EQUAL 180 DEGREES. Avoidance: There are two possible avoidances: 1. Add the G12 field to the MAT8 entry if appropriate. or 2. Set SYSTEM(173)=2

Known Error

CR 38780

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

SSSALTERs - mmecha.v707 - possible errors It has been observed that the mmecha alter may fail due to a singularity problem. This problem is due to an incorrect maxratio test in the presence of 2x2 pivots. This type of pivot can be caused by the Lagrange Multiplier Method.

Description Avoidance: The revised alter for Version 70.7 is available on the MSC.Software website. If you have trouble getting the updated alter, contact your local support representative. Known Error

CR 38788

Product

MSC / MD Nastran

Corrected Version 70.5 Abstract

Static Analysis - STRESS, CORNER, PUNCH - Missing Grid ID

Description

When requesting punch output for element forces or stress at the corners , the punch file does not print the grid ID. It does not know wich fields are integer and which fields are floating point Avoidance: There is no avoidance.

Known Error

CR 38815

Product

MSC / MD Nastran

Correcte 2005 d Version Abstract Distributed Memory Parallel - DMP - Sigbus Error on SGI Descripti SGI distributed memory parallel jobs that request 8 or more processors may on fail with a "SIGBUS: Bus error" as follows:

Known Error

CR 38815 Core from signal SIGBUS: Bus error (dbx) where > 0 _realloc(0x100193e8, 0x190, 0x19450152, 0x0, 0x110, 0x9436c5a, 0x94369bd, 0x94369d2) ["/xlv43/6.5.7m/work/irix/lib/libc/libc_n32_M4/gen/malloc.c":367,0xfb2a1fc] 1 parse_file(0x111, 0x1, 0x19450152, 0xfb51ef8, 0x110, 0x9436c5a, 0x45,0x94369d2) ["/home/poppy08/kak1/mpt/1.3/mpi/lib/libxmpi/libxmpi_n32_M3/all/all_parse.c":2 64,0x9406214] 2 parse_global_opts(0x9425388, 0x1, 0x19450152, 0xfb51ef8, 0x110, 0x9436c5a, Avoidance: The following changes need to be made to the nast707.dmp file: From: %MSC_ARCH=irix64:% print -nu3 -- "${hosts[$i]} -np 1 ${rcmds[$i]} -c$i -d%r.debug% jid=$jid $args" To: %M

Known Error

CR 38839

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Superelements - SEBULK, Collectors - SWM 3001 (READ) If component modes are requested on a collector superelement then the run will fail with SWM 3001 in READ.

Description

Avoidance: Insert the following DMAP alter: compile phase0 alter 'call ifps1' if ( setype='colltr' ) equivx dynamic/dynamics/-1 $ endalter

Known Error

CR 38841

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Installation - Poor Error Message

Description

If MSC.Nastran is NOT installed on a remote node properly, then the following error may occur: *** USER WARNING MESSAGE (pgm: nastran, fn: validate_dmp_hosts) beowulf21(LAM n1): No response from MSC.Nastran remote query:

Known Error

CR 38841 /scratch/msc/bin/nast707 -d0 -rN70.7 frs=/scratch/DMP/dmp_108.dat drwx=/tmp fw=/scratch/DMP/dmp_108.T6084_15 drwx=/scratch/DMP drwx=dmp_108 drwx=. Segmentation fault (core dumped) Avoidance: Install MSC.Nastran correctly on the remote node. If there is not an authorization file, then the following error may occur: *** USER FATAL MESSAGE (pgm: nastran, fn: validate_authorize) authorize="???????"Å (LM_LICENSE_FILE) This file does not exist. Avoidance: Install the an authorizatoin file.

Known Error

CR 38869

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Description

Documentation -- DMAP Module Dictionary - APPEND 1st param cannot be 0 Both the Version 68 DMAP Module Dictionary and the current Version 70.7 online pdf documentation indicate that the 1st parameter for the APPEND module may be either a "0" or a "1" in order to create an output datablock [IN1:IN2]. However, if "0" is used then "UFM 5005 INVALID VALUE OF OPTION PARAMETER DETECTED 0" is issued, followed by "SFM 3007 MODULE = APPEND ILLEGAL INPUT TO SUBROUTINE APPEND". Avoidance: Set the 1st parameter to "1" instead of "0".

Known Error

CR 38889

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

GPFORCE - TEMP(LOAD) - Wrong Answers The applied load contribution of the GPFORCE output is incorrect in TEMP(LOAD) is applied to only a portion of the model.

Description Avoidance: The only avoidance is to put a small thermal load on ever element. .

Known Error

CR 38892

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Optimization/Design Sensitivity - SYSTEM(2), DOPTPRM - Undocumented Feature If the IPRINT parameter on the DOPTPRM entry is used to obtain intermediate prints from the DOT optimizer, the output is always written to unit 6 regardless of which unit other "f06" output is directed to by NASTRAN SYSTEM(2).

Description Avoidance: Undocumented paramter IWRITE can be used on the DOPTPRM entry to direct the intermediate prints to the unit of the users choice. That is IWRITE=4 places this output in the .f04 file. Known Error

CR 38895

Product

MSC / MD Nastran

Corrected Version 70.7.2 Abstract Description

DMAP - PARAML - U1 Set not Recognized Degree of freedom Set U1 is not recognized by DMAP modules dealing with degree of freedom sets, e.g. PARAML, VEC, etc. Avoidance: The only avoidance is not to use the U1 set.

Known Error

CR 38898

Product

MSC / MD Nastran

Corrected Version 70.7.3 Abstract

Description

Performance - SYSTEM(107) - Poor Performance If Parallel processing is selected with SYSTEM(107) (a.k.a. keyword PARALLEL) on MSC.Nastran Version 70.7 on the Cray J-90 executable cache memory will be disabled and poor performance results. Avoidance: Other than not selecting parallel there is no avoidance.

Known Error

CR 38899

Product

MSC / MD Nastran

Corrected Version Abstract

Nonlinear Analysis - HEXA - Poor Convergence

Description

Poor convergence may be experienced for Nonlinear jobs with HEXA elements

Known Error

CR 38899 in MSC.Nastran Version 70.7. The problem occurs because the new HEXA formulation introduced for linear analysis in Version 70.7 is used on the first iteration and it shouldn't be. Avoidance: Set SYSTEM(309)=1 to revert to the pre-Version 70.7 formulation for all iterations.

Known Error

CR 38907

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Complex Eigenvalue Analysis - CEAD - UWM 5411 (REIGL8) The message below may appear many times when using the complex eigensolver module CEAD.

Description

*** USER WARNING MESSAGE 5411 (REIGL8) NEGATIVE TERM ON DIAGONAL OF MASS(VIBRATION) OR STIFFNESS(BUCKLING) MATRIX DETECTED. ROW NUMBER = 80 VALUE = -1.20000D+02 Avoidance: This message may be safely ignored when encountered in the CEAD module.

Known Error

CR 38925

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Nonlinear Static Analysis - slideline contact, PELAST - SFM 3001 in EMG Job will fail in SOL 106 when line contact problem includes nonlinear springs in the model. For example, any SLIDE-LINE model with PELAST and/or PBUSHT, which refer to TABLEDi bulk data cards, will be terminated during contact nonlinear stiffness generation in SOL 106.

Description

Avoidance: Please insert the following DMAP alter into SOL 106 decks to avoid this difficulty COMPILE NLSTATIC $ ALTER 'CALL NLKR'(3),'' $ CALL NLKR MESTNL ,CSTMS ,BTOPSTF , , , BGPECT ,BGPDTH ,SILS ,USETNL ,GMNL , , ,GPSNTS ,USET1 , ,

Known Error

CR 38925 DEQATN ,DEQIND ,ETT , , , / BKELM ,BKDICT ,BKGG ,BKFS ,BKAA , , , ,BKMG / S,NO

Known Error

CR 38927

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Elements - CTETRA, PSOLID - Poor Answers, UWM 4683 (READ) MASS MATRIX The mass matrices for mid-side-noded CTETRAs are not calculated correctly if the defaults values for IN and ISOP fields on the PSOLID are not used. This may lead to UWM 4683 from the READ module and poor answers. Avoidance: Leave the IN and ISOP fields blank on the fluid PSOLIDs in order to use the defaults.

Known Error

CR 38939

Product

MSC / MD Nastran

Corrected Version 2001.0.1 Abstract

Licensing - FlexLm - Problem with FlexLm on Windows 2000

Description

In some instances, the authorization process on NT and Windows 2000 may take almost a minute to return with the authorization. If this is happening, add the following line to your .rcf file SYMBOL=LM_NO_SNMP=1

Known Error

CR 38949

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Submittal - hosts keyword on nast707 command is ignored If the hosts keyword is defined in any of the RC files, then you will be unable to override it's value on the command line.

Description

Avoidance: A work around is to put the keyword in a local RC file in the directory where the input file resides. This value will override any values set in the other RC files.

Known Error

CR 38951

Product

MSC / MD Nastran

Corrected Version 2001

Known Error

CR 38951

Abstract

Submittal - Execution on remote node may cause input and output to be deleted. If a Nastran analysis is run on a remote system using the the node keyword, and the output file directory is visable to the remote node, then all the output files and the input files will be deleted after the job has run.

Avoidance: There are two avodiances. 1) Run the job in a directory that is not visable to the remote node Description

2) Make the following change near the end of the install_dir/bin/nast707.rmt file. 127,128c127 < %s.rsh% %node% -l %username% /bin/rm -f "%r.out%*" < %r.outvis=y:%/bin/rm -f "%r.out%*" --> %r.outvis=n:%%s.rsh% %node% -l %username% /bin/rm -f "%r.out%*"

Known Error

CR 38955

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

DMAP - PARAML - Overflow Exit, Floating Point Exception When the PARAML module is used to extract an element from a matrix with the DMI option, and the element is larger than the range allowed by single precision parameters, a machine-dependent overflow error exit occurs. On NT MSC/NASTRAN, the output from the f06 file is:

Description

0THE NUMBER OF NON-ZERO TERMS IN THE DENSEST COLUMN = 1 0THE DENSITY OF THIS MATRIX IS 100.00 PERCENT. MAIN: The FPU has been reset after floating point exception. MAIN: For reference, A(MAINAL) = 405290, A(/SYSTEM/) = 1777f60 [similar data is presented in the .log file] There is no mention in any of the diagnostic output that the PARAML module was being executed when the overflow occurs. One diagnostic method is to temporarily put a message statement in front of every suspected module ca

Known Error

CR 38960

Product

MSC / MD Nastran

Corrected Version 2005.5

Known Error

CR 38960

Abstract

Documentation/QRG - PELAST, PBUSHT - Unexpected Answers

Description

If the initial slope of the nonlinear force-displacement relationship defined on a PELAST or PBUSHT entry in a nonlinear solution does not match the corresponding Ki value on the PELAS or PBUSH entry, then the results may be unpredictable. Avoidance: Make sure that the initial slope as defined on the TABLEDi entry matches the corresponding Ki value on the PELAS or PBUSH entry.

Known Error

CR 39031

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Documentation - DMAP Module Dictionary - MATMOD Option 5, Form 3 Example 3 under the DMAP Module Dictionary's description of MATMOD option 5 should be modified from Transform KGGBASIC coordinate system 10.

Description

MATMOD CSTM,SIL,,,,/TRANS10,/5//10 $ TRNSP TRANS10/TRANST10T $ SMPYAD TRANS10,KGGBASIC,TRANS10T,,,/KGG10/3 $ to Transform KGGBASIC to coordinate system 10. MATMOD CSTM,SIL,,,,/TRANS10,/5//10 $ TRNSP TRANS10/TRANST10T $ SMPYAD TRANST10T,KGGBASIC,TRANS10,,,/KGG10/3 $

Known Error

CR 39041

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Optimization/Design Sensitivity - PARAM,NOCOMPS -1 not supported on DRESP1 PARAM NOCOMPS -1 is used to recover shell element stresses for an equivalent homogeneous element. The use of this capability has been blocked in SOL 200 so that if the user invokes the equivalent PSHELL on the DRESP1 entry to obtain stress/strain responses of the element, the corresponding PSHELL will not be found.

Known Error

CR 39041 Avoidance: There is no avoidance. Version 2001 will remove this restriction.

Known Error

CR 39046

Product

MSC / MD Nastran

Corrected Version Abstract

File Management Section - DBDICT - Missing Dictionary If the DBDICT FMS command is used in a run as follows, the dictionary will be blank. assign master='oldrun.MASTER' DBDICT endjob

Description

Avoidance: Use a read-only restart similar to the following to list the database dictionary. assign run1='oldrun.MASTER' restart, logical=run1 dbdict sol 101 cend begin bulk enddata

Known Error

CR 39056

Product

MSC / MD Nastran

Corrected Version 2001.0.1 Abstract

Grid Point Stress - GPSTRESS- 4276 (FREAD) If GPSTRESS output is requested, then following error may occur. SYSTEM FATAL MESSAGE 4276 (FREAD).

Description Avoidance: Ensure that case control requests for stress and force specify the same type of output. If center and grid point output is specified for one, it should also be specified for the other. Known Error

CR 39067

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Distributed Memory Parallel - DMP, READ - Poor Performance

Description

Distributed Memory Parallel eigenvalue jobs may experience poor performance

Known Error

CR 39067 in READ on Compaq Alpha clusters. Avoidance: There is no avoidance. I can't find the data deck. But this csr has the same issue to vvpr 120092 which Joe Griffin had verified the performance of this job. So I consider it's verified. -TIN-

Known Error

CR 39088

Product

MSC / MD Nastran

Corrected Version 2005.1 Abstract

Cyclic Modes - SFM 3001 (DCMP) The following message may occur in a cyclic symmetry modal run (SOL 115) when requesting a tridiagonal solution method such as AHOU or AGIV. The message is output from the DCMP module if the USET and SIL tables are mismatched with the input matrices. *** SYSTEM FATAL MESSAGE 3001 (DCMP) THE INPUT DATA BLOCK IN POSITION 3 DOES NOT EXIST.

Description

Avoidance: An avoidance is to use the Lanczos method which does not perform this operation. Another avoidance is to use the DECOMP module instead: Compile moders list noref $ Alter 'dcmp.*kww1'(,-1) $ If (cyclic) then $ Decomp kww1/lww1,, $ Else $ Alter 'dcmp.*kww1' $ Endif $

Known Error

CR 39098

Product

MSC / MD Nastran

Corrected Version 2001 Abstract Description

Documentation/QRG - PARAM,USETPRT and PARAM,SETSTR1 In Version 70.7 param,usetsel has been changed such that values greater than 0. are not acceptable. If USETSEL is set greater than 0 the following message occurs:

Known Error

CR 39098 ^^^ USER WARNING MESSAGE 9109 (SEKR0) ^^^ USETSEL IS GREATER THAN ZERO WHICH IS OBSOLETE. USETSEL WILL BE RESET TO -1 TO PRINT ALL SETS. ^^^ USER ACTION: SPECIFY PARAM,USETSEL,0 AND SET NAMES ON PARAM,USETSTR1 THRU USETSTR4. Avoidance: The syntax for the r USETSTRi paramerter is: PARAM,USETSTR1,M:R for more info see the description under TABPRT in the Release Guide for Version 70.7.

Known Error

CR 39109

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Description

Eigenvalue Analysis - GIV, MGIV, HOU, MHOU - Poor Answers When using methods GIV, HOU, or their variants, if there are repeated roots their eigenvectors may not be orthogonal. A small test problem with 9 repeated roots produced only three orthognal vectors. Avoidance: An avoidance is to use the LAN method.

Known Error

CR 39125

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Elements - CRAC3D, MAT9 - UFM 3005 If a model has CRAC3D elements that reference MAT9 entries, then the job may fail with the following error messages:

Description

**** USER FATAL MESSAGE 3005 (SNGERR) Attemp to operate on singular matrix AI in subroutine SD92ND. Avoidance: There is no known avoidance.

Known Error

CR 39129

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

DMAP - DIAGONAL - UFM 5250 DIAGNL Negative non-integer exponent

Description

If the diagonal terms of a matrix are raised to a negative power using the DIAGONAL command with the 'SQUARE' option, if there are negative offdiagonal

Known Error

CR 39129 terms, the program will fail with: UFM 5250 DIAGNL Negative non-integer exponent Avoidance: First extract the diagonal terms using a POWER of 1.0, then raise the resulting matrix to the desired negative power.

Known Error

CR 39150

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

DSAPRT, TRIM, STABDER, - Formatted Output not Supported The formatted sensitivity prints produced using the DSAPRT case control command are not supported for aeroelastic responses (DRESP1 RTYPE = TRIM, STABDER or FLUTTER Avoidance: Use the unformatted sensitivity prints.

Known Error

CR 39168

Product

MSC / MD Nastran

Corrected Version Abstract

DMAP - Access Violation Error A dmap had a purged input data block of the form call xyz a,,c . . . It in turn called another dmap, with the format call wyz b// $, where b is the purged input. If an attempt was made to test for the presence of b with paraml or to print it with matprn, an access violation occurs. If all inputs to a subdmap are purged, an executive system error occurs.

Description

Avoidance: An avoidance is to add another non-purged datablock to the calling argument. This purged argument does not need to be used in the subdmap. Its presence avoids the error that results when all inputs to the subdmap are purged

MAIN: "Access violation" (C0000005) exception encountered.

Known Error

CR 39172

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

DMAP - paraml /dbname/'name' - Datablock is discarded If the paraml option 'name' is used on a data block in the calling argument of a subdmap, and the datablock used as input to paraml is an NDDL-scratch data block that has previously been equivalenced, the data block is discarded at the end of the subdmap. Avoidance: There is no known avoidance.

Known Error

CR 39191

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Aeroelastic Analysis - SDR1 - UFM 4574, SWM 3001 UXAX Does not exist Aeroelastic analyses that result in no a-set elastic deformations for unit perturbations of the controllers will result in the following error message: *** USER FATAL MESSAGE 4574 (SDR1) DATA RECOVERY STARTED BUT NO DISPLACEMENT VECTORS AVAILABLE *** SYSTEM WARNING MESSAGE 3001 (SDR1) THE INPUT DATA BLOCK NAMED UXAX AT POSITION 3 DOES NOT EXIST.

Description The problem is that UXAX is purged because there are no elastic deformations. This is a somewhat rare event, that can happen if you attempt to model a "rigid" airplane. There are a number of ways in which a rigid airplane can be better modelled. In particular, in the TRIM specification, you can set the AEQR field to 0.0. That will result in a flexible vehicle with no elastic feedback to modify the aero loads. This is t Known Error

CR 39198

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

DMAP - MATGPR - UWM 3059

Description

If the 2nd parameter is unspecified on the MATGPR DMAP module, then UWM 3059 is issued. This warning can be safely ignored. Avoidance: Specify the 2nd parameter.

Known Error

CR 39203

Known Error

CR 39203

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Nonlinear Analysis - PARAM,POST - Missing Postprocessing Output PARAM,POST does not work correctly in the Case Control of a Version 70.7 Nonlinear run. Avoidance: Insert the following DMAP alter;

Description

COMPILE NLSTATIC alter 'PVT PVT,CASESX2','' dbstatus casesx2//s,n,nocase2 $ if ( nocase2>0 ) PVT PVT,CASESX2/ $ endalter

Known Error

CR 39208

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Plotting - XYPLOT, XYTRAN - Missing Plot Output

Description

If a non-existant grid point is requested by the XYPLOT command, the XYTRAN module makes a premature exit. i.e. when a displacement plot command cannot find the grid point, all of the acceleration and element stress/force plots could be skipped.

Known Error

CR 39213

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Dynamic Anaysis - FRLG - Wrong Answers. In MSC.Nastran it has been found that FRLG can produce incorrect loads when insufficient memory is given.

Description

Avoidance: If the answers are suspect, run the analysis at only the suspected problem frequencies and see if the answers change. If the answers change increase memory and rerun the job.

Known Error

CR 39215

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Mass Matrix - UFM 4646, Grids and Components not Identified

Description

The indefinite mass matrix check may not correctly identify the grid point and degree of freedom.

Known Error

CR 39215 AN INDEFINITE MASS MATRIX DOF DETECTED AT GRID: 0 COMPONENT: 0 Avoidance: The run may be allowed to continue by setting system(303). MSC's elastic elements do not produce an indefinite mass matrix. Massless mechanisms may cause this error, dmig input, or improperly coded rigid elements.

Known Error

CR 39219

Product

MSC / MD Nastran

Corrected Version GL Abstract

Complex Eigenvalue Analysis - EIGC - Missing Eigenvalues In MSC.Nastran Version 70.7 the new Block Complex Lanczos Eigenvalue analysis method automatically reverts to real operations when no damping matrix exists. This may cause roots to be missed in acoustic/fluid problems.

Avoidance: Two possible avoidances are: Description

1. Introduce a false damping matrix by applying the following alter: compile gma alter 'acsyml\=','' acsyml=(acsym='yes' and fs) $ endalter 2. Force the method to always use complex arithmetic by setting system(108)=16384.

Known Error

CR 39224

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Optimiztion/Design Sensitivity - PBEAM - UFM 7055 When an optimization task tries to design K1, K2 and other quantities specified on the last two continuations of a PBEAM entry, then USER FATAL MESSAGE 7055 (DOPR1C/DOPR1Z) will be printed.

Avoidance: Do not design K1, K2 and others on the last two continuations of the PBEAM entry. Known Error

CR 39235

Known Error

CR 39235

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Optimization/Design Sensitivity - UFM 3001 (DSAL) In a SOL 200 senstivity analysis with multiple frequency subcases, an error can result if an initial subcase has no responses that require a direct (as opposed to adjoint) sensitivity analysis and a subsequent subcase does.

Description Avoidance: A possible avoidance is to arrange the subcases so that any that the initial subcase requires a direct analysis. Another avoidance is to force the use of the direct senstivity calculation for all subcsases with PARAM AUTOADJ NO. Known Error

CR 39248

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Optimization/Design Sensitivity - DVPREL1, PBEAML, PBARL - UFM 7193 USER FATAL MESSAGE 7193 may be issued in error when there are both PBARL and PBEAML entries being designed. The error does not occur when a single PBARL is designed.

Description Avoidance: The only avoidance is to replace either the designed PBARL's or the PBEAML's with PBAR's of PBEAM's and use the original dvprel1/dvprel2 techniques to design these properties. Known Error

CR 39269

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Optimization/Design Sensitivity - DRESP2 - SFM 4027 (WRITE), EC 3021 An optimization task may fail with the SYSTEM FATAL MESSAGE 4027 when the following two conditions are met: 1) a DRESP1 response is referenced in the first subcase and 2) a DRESP2 response is retained in the second subcase where the DRESP2 response references to another DRESP2 entry. Avoidance: Do not use a DRESP2 referencing a DRESP2.

Known Error

CR 39272

Product

MSC / MD Nastran

Known Error

CR 39272

Corrected Version 2001 Abstract

Optimization/Design Sensitivity - DRESP2 - Wrong Answers An optimization task may generate incorrect type 2 response values when the nested referenced DRESP2 entries are used in multiple subcases.

Description Avoidance: There is no avoidance.

Known Error

CR 39273

Product

MSC / MD Nastran

Corrected Version 2001.0.1 Abstract

Elements - HEXA, Corner Stresses, SDR2 - Possible Wrong Answers In Version 70.7, if the HEXA element is highly distorted, then the corner stresses may be incorrect. The element center stresses are correct. Avoidances: There are two possible avoidances.

Description

1. Use the version 70.5 HEXA formulation by adding nastran system(309)=1 to the top of the input file 2. Do not use the corner stress values.

Known Error

CR 39275

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Optimization/Design Sensitivity - MODTRK, FREQ3, 4, 5- SFM4276 (GREAD) In SOL 200, SYSTEM FATAL MESSAGE 4276 may be issued if mode tracking is requested and there is a modal frequency subcase that uses the FREQ3, FREQ4, or FREQ5 entries. in the specification of the excitation frequencies.

Description

Avoidance: The use of FREQ3, 4 or 5 is not recommended with sensitivity and optimization analysis since the excitation frequencies are not updated when the structural model is changed. Further, the sensitivity calculations ignore the effect of the change on the excitation frequency on the design response and are therefore inaccurate, at best, and may cause the design to go in the wrong direction.

Known Error

CR 39280

Product

MSC / MD Nastran

Known Error

CR 39280

Corrected Version 2001 Abstract

Documentation - QRG - SET description under OUTPUT(POST) Missing Keywords

Description

The SET description on page 244 of the V70.5 QRG for OUTPUT(POST) is the missing keywords [ELEMENTS, GRID POINTS].

Known Error

CR 39285

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Optimization/Design Sensitivity - PARAM EIGD, DSAPRT(EXPORT), IUNIT SUBDMAP EIGVECDS does not contain the parameter iunit. Thus, when the DSAPRT(EXPORT) Case Control command is used, OUTPUT4 fails because IUNIT is undefined. Avoidance: Apply the following alter:

Description

INIT MASTER(S) assign output4='a200.op4' unit=21 formatted delete $ ID MSC, SWRO TIME 100 DIAG 5,6,8,56 SOL 200 $need to rewind iunit before anything else malter 'file.*append' output4 //-1/iunit $ $ need to modify output2 from rewind to do nothing malter 'output2.*dscmcol','output2.*dscmcol' OUTPUT2 DSCMCOL,,,,//0/IUNIT/'DSCMCOL'/OMAXR $ compile eigvecds,nolist alter 'nddl' TYPE PARM,NDDL,I,Y,iunit $need iunit id subdmap eigvecds alter 'output4' message // 'iunit='/iunit $ alter 'output4'(2,0),'output4'(2,0) $ remove rewind of iunit $exit

Known Error

CR 39288

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Elements - CTETRA, PSOLID - UFM 9050 (SEKRRS)

Known Error

CR 39288 If a CTETRA with midside nodes references a PSOLID that has the IN field equal to "TWO", the following error message occurs:

Description

^^^ USER FATAL MESSAGE 9050 (SEKRRS) ^^^ RUN TERMINATED DUE TO EXCESSIVE PIVOT RATIOS IN MATRIX KLL. ^^^ USER ACTION: CONSTRAIN MECHANISMS WITH SPCI OR SUPORTI ENTRIES OR SPECIFY PARAM,BAILOUT,-1 TO CONTINUE THE RUN WITH MECHANISMS. NASTRAN should give a warning message saying that IN = "TWO" is not allowed and that the suggested IN = "THREE" is used instead, and the run should continue. Avoidance: Use IN equal to "THREE".

Known Error

CR 39294

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Optimization/Design Sensitivity - DRESP2, DNODE - Incorrect Sensitivities

Description

When an optimzation task includes a DRESP2 entry which also references a DNODE and another DRESP2 entry, incorrect sensitivity coeffcients for the DRESP2 entry may be produced. Avoidance: Do not reference both DNODE and DRESP2 on a DRESP2 entry.

Known Error

CR 39304

Product

MSC / MD Nastran

Corrected Version GL Abstract

Postprocessing/Cyclic Symmetry Normal Modes - DBC, PARAM,POST,0 Incorrect Results in XDB

Description

Cyclic Symmetry Modal Analysis produces incorrect XDB outputs. The results for modes may be truncated.

Known Error

CR 39309

Product

MSC / MD Nastran

Corrected Version 2001 Abstract Description

P-elements - GP0 - GMLOAD applied to GMCURV for CBEAMs For p-elements, if a GMLOAD is applied to a GMCURV in order to load CBEAMs, a fatal error with no additional information occurs in GP0.

Known Error

CR 39309 Avoidance: The avoidance is to apply the GMLOAD to the individual FEEDGEs for the CBEAMs.

Known Error

CR 39314

Product

MSC / MD Nastran

Corrected Version Abstract

Nonlinear Analysis - UIM 9005, Saved LOOPID is not correct Even when an increment in nonlinear statics (SOL 106) cannot converge, it still prints the following message, where "n" is the loopid of the unconverged increment:

Description

^^^ USER INFORMATION MESSAGE 9005 (NLSTATIC) ^^^ THE SOLUTION FOR LOOPID= n IS SAVED FOR RESTART This message is not true since increment "n" has not been saved for restart. Avoidance: Ignore the message since only increments up to n-1 have been saved.

Known Error

CR 39326

Product

MSC / MD Nastran

Corrected Version GL Abstract

Database - SFM 1041 (GALLEX) A limit in the database directory size may cause large jobs to fail with the message SYSTEM FATAL MESSAGE 1041 (GALLEX).

Description

Avoidance: This limitation can be overcome by increasing the buffsize and/or setting system(158)=1000 and system(159)=500 to allow for a larger expansion of the database.

Known Error

CR 39342

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

DMAP - DEFUSET - Entry Ignored without Warning

Description

The DEFUSET function was removed in Version 70.7. Any such bulk data entries are now ignored, without warning. Avoidance: There is no known avoidance.

Known Error

CR 39375

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

FMS - ASSIGN, scr=yes - Database Not Deleted :q vi rIn Version 70.7, if an ASSIGN statement is specified for the database, the database will not be deleted at the end of the job even if scr=yes is specified on the command line.

Description

Avoidances: There are two possible avoidances. 1. Add the following FMS statement to the input file init master(s) 2. Add a ",temp" to the end of the assign statement.

Known Error

CR 39378

Product

MSC / MD Nastran

Corrected Version Abstract

Description

Beam Library - CONNECT - Incorrect Properties for Multiple Beam Servers When more than one beam server is used, it may produce incorrect the properties. This error occurs whe the Group names or evaluator class names show certain pattern in which the first portion of the n-th group name is identical to the name of the (n-1)-th group where n is => 2. In addition the CONNECT entry including (n-1)-th group must precede the CONNECT entry containing n-th group name. For example, the CONNECT entries given here will produce the incorrect properties for the beamsrv1 group: CONNECT BEAMEVAL beamsrv locbml and CONNECT BEAMEVAL beamsrv1 locbmls. Avoidance: Do not use the problematic pattern as the group name for multiple beam servers.

Known Error

CR 39386

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation/QRG - PARAM,S1 - Incorrect Documentation for SOL 109 and 112

Description

Stress sorting was implemented in SOL's 109 and 112 in Version 69. The QRG incorrectly shows that the associated parameters are not supported for

Known Error

CR 39386 these solutions. .

Known Error

CR 39387

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Optimization/Design Sensitivity - DRESP2 - SFM 3007 DOM9 An optimization task may fail with the 'SFM 3007 DOM9, SUBROUTINE DOM91' message when the DRESP2 response references another DRESP2 entry. Avoidance: 1) Convert the offending DRESP2 entries into a single DRESP2 entry or 2) Use the following dmap alter:

Description

For v70.7 COMPILE DESCON alter ' DSAD ' DBSTATUS RR2IDR//S,N,NORR2ID $ IF ( NORR2ID>0 ) THEN PARAML RR2IDR//'TRAILER'/1/S,N,NRR2 $ TYPE PARM,,I,N,NRR2I NRR2I = NRR2 PARAML RR2IDR//'DTI'/1/ S,N,NRR2I//S,N,R2ID $ IF (R2ID = 0) THEN MODTRL RR2IDR //0 $ ENDIF ENDIF

Known Error

CR 39391

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Optimization/Design Sensitivity - EIGN, FREQ, FLUTTER - Wrong Sensitivities Incorrect sensitivities can be produced in SOL 200 when all of the following pertain:

Description

a. There are superelements b. A global response is selected as the objective c. The response is not WEIGHT or VOLUME. An example of responses are EIGN, LAMA, FREQ and FLUTTER. Correct answers are provided when the response is constrained. It is only when it is invoked by the DESOBJ case control command that incomplete

Known Error

CR 39391 sensitivity information is provided.

Known Error

CR 39422

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Distributed Memory Parallel - Execution fails with large value of "dmp"

Description

Nastran runs with large values of the "dmp" parameter will fail in the setup of the run. The exact value that is allowed is a function of various factors like the size of the current path name.

Known Error

CR 39426

Product

MSC / MD Nastran

Corrected Version 2001.0.1 Abstract

Description

Optimization/Design Sensitivity - Multiple Eigenvalue Subcases - Missing Output If two eigenvalue subcases with different boundary conditions are run in SOL 200, the second subcases eigenvalues are printed twice but the first is not printed. The eigenvector results are printed correctly and the optimzation is performed correctly. Avoidance: Setting NASPRT=1 will produce correct eigenvalue results at each design iteration, including the last. Version 70.5 can also be used to get the correct prints.

Known Error

CR 39433

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Known Error

Inertia Relief - PARAM,INREL,-2 - UWM 4698 When a matrix to be decomposed requires 2 by 2 pivots, its rows may be identified as having negative factor terms by maxratio and USER WARNING MESSAGE 4698 may be issued. 2 by 2 pivots most commonly occur when using Lagrange Multiplier techniques (LMT). The max ratio test is not valid for this circumstance, so this warning message may be ignored. LMT methods are used in sol 101 for param, inrel, -2.

CR 39436

Known Error

CR 39436

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Aeroelastic Analysis - PARAM,POST,0 - Complex Eigenvectors Missing from xdb If complex eigenvalues/vectors are extracted using the pk method, they cannot be written to the xdb file (PARAM POST 0) due to an error in the datablock labelling Avoidance: The op2 file (PARAM POST -1) can be used to display complex eigenvectors in MSC.Patran

Known Error

CR 39439

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Inertia Relief - PARAM,INREL,-2 - Poor Performance When the automated suport capability for inertia relief is selected (param, inrel, -2) the problem may run many times slower than when other methods of inertia relief are used. Avoidance: A dmap avoidance is given in the sssalter library with the name ir2a.v707.

Known Error

CR 39440

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Optimization/Design Sensitivity - PCOMP - Wrong Answers If any thickness of the various plies on a PCOMP entry is defined as a design variable, Z0 is blank, and a DVPREL1 or DVPREL2 has not been used to define ZO, then wrong answers may occur. This error occurs because the the initial Z0 is used for the entire design optimization task even though Z0 changes as the ply thicknesses change.. Thus, sensitivities and optimization results are wrong.

Description Avoidance: A DVPREL1 or DVPREL2 entry must be used to define Z0 ( Z0 =0.5 times the element thickness). Otherwise, the initial Z0 will be used for the entire design optimization task even though Z0 changes as the ply thicknesses change.. Thus, sensitivities and optimization results are wrong for Z0=blank without DVPREL1 or DVPREL2 definition.

Known Error

CR 39449

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation/Plotting - CTETRA iem codes for nonlinear are wrong The Stress-Strain Item Codes, in Appendix A, of nonlinear HEXA, PENTA and TETRA are wrong in the current Quick Reference Guide, The errors and corrections are listed as follows: 1) The last row of Nonlinear CHEXA (Code=93), "19-146 Items 3 through 17 Repeated for 8 corners", should be changed to

Description

"19-146 Items 3 through 18 Repeated for 8 corners ". 2) The last row of Nonlinear CPENTA(Code=91), "19-146 Items 3 through 17 Repeated for 8 corners", should be changed to "19-114 Items 3 through 18 Repeated for6 corners". 3) The last row of Nonlinear CTETRA(Code=85), "19-146 Items 3 through 1

Known Error

CR 39452

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

External Superelements - ASET, USET, Residual Vectors - Possible Wrong Answers

Description

If an explicit ASET and a user USET (i.e. U1, U2, U3, U4, U5, or U6) are specified, then the USET table is corrupted. The ASET will be reduced by the dof which are common with the user set (u1-u6). and wrong answers may occur.

Known Error

CR 39473

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Nonlinear Analysis/Hyperelastic Elements - PLSOLID, MATHP, PCOMP - SFM 3003

Description

When hyperelastic material properties (PLSOLID and MATHP) are used together with composites (PCOMP) or the alternate form of beam property (PBCOMP) in a nonlinear analysis, Nastran fails in IFP6 if MATHP refers to any TABLES1

Known Error

CR 39473 entry. Avoidances: This error can be avoided if user specifies the material constants instead of using tables.

Known Error

CR 39490

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Nonlinear Transient Analysis - NLTRD2 - SFM 4276 UNPACK It is possible that a nonlinear transient analysis may fail with BIOMSG 33, followed by SYTEM FATAL MESSAGE 4276, indicating an UNPACK error.

Description

Avoidance: The exact cause of this problem is under investigation. One potential cause is epoints. Replacing epoints with spoints may solve the problem.

Known Error

CR 39508

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Nonlinear Analysis/Hyperelastic Elements - PLSOLID, MATHP Nastran job may fail in nonlinear analysis when the specified number(s) of NA (order of polynomial function of the distortional strain energy) and/or ND (order of polynomial function of thethe volumetic strain energy) in MATHP card are higher than the real rank(s). The real ranks are computered from user specified material constants (Aij and Di) or tables (TABLES1) in MATHP bulk data card by NASTRAN automatically. Avoidances: This error can be avoided if user controls the number of order of NA and ND - don't make them higher than the possible ranks based on the user's input of Material constants (Aij) or Tables (TABLES1) in the MATHP bulk data card.

Known Error

CR 39509

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Description

Transient Analysis - PARAM,ADSTAT, LFREQ, STATSUB - UFM 6143 If a modal transient analysis is run using PARAMs ADSTAT and LFREQ and the case control command STATSUB, then the run will fail with UFM 6143 indicating incorrect input to the MERGE module.

Known Error

CR 39509 Avoidance: Insert the following DMAP your file: compile super3 alter 'matmod.*lm1.*mass' type parm,,rs,y,lfreq if(lfreq>0.)then $ $ $ correct error if ADSTAT, LFREQ, STATSUB are all used $ this is a simple correction and will not work for the general case $ paraml freq//'trailer'/2/s,n,nmodes $ type parm,,i,n,rmmodes rmmodes=nmodes-NRUH1 $ number of modes removed by LFREQ - NOTE this alter does $ not check for HFREQ or NMODES matgen ,/lfmodes/6/nmodes/rmmodes/NRUH1 $ partitioning vector based on removed modes partn freq,,lfmodes/,nfreq,,/1 $ partn mass,,lfmodes/,nmass,,/1 $ equivx nfreq/freq/-1 $ equivx nmass/mass/-1 $ endif $

Known Error

CR 39510

Product

MSC / MD Nastran

Corrected Version Abstract

Nonlinear Analysis - Incorrect Loadstep ID after UIM 6189 If a Nonlinear analysis issues the message: *** USER INFORMATION MESSAGE 6189 (NCONVG) *** BEST ATTAINABLE SOLUTION HAS BEEN FOUND ***

Description

Then for the next load increment the 3 permitted bisections are going to take place without convergence. The displacement output for the "BEST ATTAINABLE SOLUTION" will then be labeled with a load factor that includes the increment from the final step with 3 bisections. Avoidance: Set the intermediate output (INTOUT) field 9 on the NLPARM entry to YES.

Known Error

CR 39556

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Eigenvalue Analysis - EIGRL, READ - UFM 5401

Description

USER FATAL MESSAGE 5401 is issued when a Lanczos job does not find any roots. Possible causes are given. One cause that is not given in the message is a large maximum ratio indicating a modeling error.

Known Error

CR 39560

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Optimization/Design Sensitivity - ANALYSIS=FLUTTER SFM 4276 (tbk) at DSAPRT,DSAD A design optimization analysis may fail in the DSAD or DSAPRT modules if ANALYSIS=FLUTTER

Description

*** SYSTEM FATAL MESSAGE 4276 (tbk) ERROR CODE 7777 PID= 0 *** USER INFORMATION MESSAGE 4276 (tbk)

Known Error

CR 39572

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Normal Modes - SOL 103 - Bad Eigenvalues Bad eigenvalues may occur on the Version 70.7.2 NEC system with a build date of December 15, 1999. This error has been corrected in Version 70.7.2 on the R3 CD. The error was fixed without changing the Version. The build date of the corrected executable is June 28, 2000. Avoidance: There is no avoidance.

Known Error

CR 39609

Product

MSC / MD Nastran

Corrected Version GL Abstract

Miscellaneous - SGI ffio may result in a traceback The FFIO feature may cause problems on some SGI operating systems. The jobs may stop with a traceback in ffopen.

Description

Receiving signal number 5: Trace/BPT trap Avoidance; Setting ff_io_opts = 'casecon.DB* casecon.db* casecon*SCR* casecon*scr*

Known Error

CR 39609 may solve the problem. Else turn off FFIO.

Known Error

CR 39612

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

DMAP - ORTHOG Module Incorrectly Declares a Matrix to a Null Matrix The ORTHOG module may incorrectly declare a matrix with small terms to be null and the following message is then issued.

Description *** SYSTEM WARNING MESSAGE 6467 (ORTHRD) A NULL COLUMN WAS ENCOUNTERED AT COLUMN NUMBER = 1 DURING ORTHOGONALIZATION Known Error

CR 39624

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

P-Elements - MATTi - Wrong Answers If temperature-dependent material properties are being used with pelement shells,and the temperature field is not constant, the answers may be incorrect. Avoidance: There is no avoidance.

Known Error

CR 39630

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Modal Frequency Response - multiple subcases, element output - Missing Output If multiple subcases exist in a modal frequency response analysis, and element-type output is requested (e.g., force) in the second or subsequent subcases without requesting it in the first subcase, then the element output will be missing.

Description

Avoidance: There are two possible avoidances. The first one is recommended. 1. Add the same request in the first subcase. If the printed output is not desired, use the (plot) option. 2. Use param,ddrmm,-1. This method is not recommended as it may cause substantial

Known Error

CR 39630 additional runtime.

Known Error

CR 39633

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Nonlinear Buckling Analysis - PARAM,BUCKLE,2 - UWM 8592 (REIG) Nonlinear buckling analysis in a cold start run was made possible in Version 70.7 by specifying param, buckle, 2. A buckling analysis should be able to be selectively perfromed for each subcase that has a method = n specified. However, if a method request is not made in each subcase the job will fail with the following message:

Description

*** USER WARNING MESSAGE 8592 (REIG) THE METHOD RECORD IN CASE CONTROL IS MISSING OR INCORRECT. THIS WILL CAUSE THE FOLLOWING FATAL ERRORS. USER ACTION: PUT A METHOD ENTRY IN CASE CONTROL WHICH POINTS TO AN EIGR, EIGRL, OR EIGB RECORD IN BULK DATA. *** USER FATAL MESSAGE 3032 (READ) UNABLE TO FIND SELECTED SET ( 0) IN TABLE (EED ) IN SUBROUTINE (REIG). 0FATAL ERROR Avoidance: Insert the following DMAP alter or make the

Known Error

CR 39636

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Aeroelastic Analysis - SPLINE - UFM 7358 In an aeroelastic analysis, USER FATAL MESSAGE 7358 may be issued in error. This has been observed to occur when the the structural grid points used by the spline are separated by a length that is much less than one.

Description

Known Error

Avoidance: Recasting the dimensions of the problem so that the distances are greater than one should provide a workaround. Another alternative is to select additional gridpoints that are outboard or inboard of the selection. This error does not occur in Version 70.5 so this version could be used as an avoidance. . CR 39643

Known Error

CR 39643

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Optimization/Design Sensitivity - PCOMP, DSAD13 - Read Past End of Record In a Nastran optimization job (sol 200) the message ATTEMPT TO READ PAST THE END OF A LOGICAL RECORD (DSAD13)

Description

is produced with composite responses (DRESP1 RTYPE = CSTRESS,CSTRAIN or CFAILURE) if the lamina number requested in the ATTA field is greater than the number of lamina on the associated pcomp entry. Avoidance: Correct the incorrect lamina number request

Known Error

CR 39663

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Beam Library - DOM9 - Segmentation Error

Description

A large optimization job that utilized the external beam library capability gave a segmentation error in the DOM9 module. This problem was traced to a time-out problem. Avoidance: Use Node Locked instead of Flexm

Known Error

CR 39682

Product

MSC / MD Nastran

Corrected Version 70.7 Abstract

Aeroelastic Analysis - GUST, RMS - Wrong Answers In a symmetric aeroelastic analysis, if an aerodynamic panel lies on the plane of symmetry wrong GUST RMS values or a rank deficient matrix result.

Description

Avoidable: For symmetric analysis do not define panels that lie on the plane of symmetry. Version 70.7 allows aerodynamic panels to lie on the plane of symmetry by implementation of the AESYMXZ and AESYMXY commands.

Known Error

CR 39695

Product

MSC / MD Nastran

Corrected Version GL Abstract

Eigenvalue Analysis - PARAM,RESVEC,YES - Traceback in READ

Description

PARAM,RESVEC,YES may cause a floating point error in READ. This occurs when the number of modes plus residual vectors exceeds the rank of the

Known Error

CR 39695 mass matrix. This problem typically only occurs in very small test models where all modes may be unexpectedely calculated. Avoidance: Modify the EIGR(L) record so not all modes are computed. If there are disjoint submodels, do not get all of the modes for any submodel for which there will be residual vectors.

Known Error

CR 39697

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

SSSALTER library - pstmac2a.v707, missing eigenvalue table - SFM 3001 When using the pstmac2a.v707 alter, if an eigenvalue table is not provided, then the job will fail with SFM 3001 Avoidance: There are two possible avoidances: 1. Provide an eigenvalue table

Description

or 2. Modify the following statement from lamx ,,lamdum1/lamat $ to lamx lamdum1,/lamat/nummodes $

Known Error

CR 39705

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Virtual Mass - MFLUIED, ZFS - UWM 5411 When using virtual mass, if any grid point of an element listed on an ELIST record lies very near the free surface, a nonpositive definite mass matrix may occur. This may result in the following message:

Description

*** USER WARNING MESSAGE 5411 (REIGL8) NEGATIVE TERM ON DIAGONAL OF MASS(VIBRATION) OR STIFFNESS(BUCKLING) MATRIX DETECTED. ROW NUMBER = 56 VALUE = -3.60212D+01 The number of modes calculated may not match the Sturm sequence

Known Error

CR 39705 output. Avoidance: Change the free surface level slightly so that no grid point lies near the free surface. Near means a distance less than one percent of the square root of the area.

Known Error

CR 39713

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Miscellaneous - DMIG - UFM 2070 (MTRXIN) DMIG matrices may be selected by the (K2gg, M2gg, and B2gg) commands, and the (K2pp, M2pp, and B2pp) commands. If the same matrix is requested twice, for example K2gg = AA $ M2gg = AA $

Description

or K2pp = AAX $ B2pp = AAX $ Then the following misleading fatal message is output: *** USER FATAL MESSAGE 2070 (MTRXIN) REQUESTED DMIG MATRIX AA IS UNDEFINED. Avoidance: Duplicate the DMIG matrix and rename.

Known Error

CR 39714

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Case Control - TFL - Poor Message, BIOMSG, ERROR 3001 MTRXIN If the Case Control contains the command TFL = [sid] but there is no TFL entry in bulk data, a non-standard exit is taken. For Version 70.7 on the NT, the following exit was taken in the MTRXIN module:

Description

BIOMSG: ERROR 3001 HAS OCCURRED IN ROUTINE FREAD , FILE INDEX = 0. STATUS = 0 Avoidance: Correct the input data.

Known Error

CR 39718

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Case Control - MPRES - Missing Output Labels If SORT2 format output is requested with the MPRESS Case Control command, the associated "PRESSURES FOR ELEMENTS ON FLUID STRUCTURE BOUNDARY" output will have no element labeling on it. Avoidance: Request SORT1 output

Known Error

CR 39724

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

SSSALTERs - modevala.v707 -MAX Eigenvector Normalization causes Wrong Ans. SSSALTER modevala.vxx assumes that the eigenvectors are normalized to unit generalized mass. If they are not, incorrect results will occur. Avoidance: Always normalize your eigenvectors to MASS (the default).

Known Error

CR 39742

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Frequency Response - STATSUB - Missing Output If there is a static subcase in SOL 111 to apply a prestress followed by a dynamic subcase, and if output requests are only in the dynamic subcase no output is obtained.

Description

Avoidance: Put the output request above all subcases or insert the following DMAP alter: compile super3 alter 'if ( desopt ) then','' if ( true ) then $ endalter $

Known Error

CR 39751

Product

MSC / MD Nastran

Corrected Version 2001

Known Error

CR 39751

Abstract

Loads - UFM 2008 (GP3) UNDEFINED GRID IN LOADSET If you have a large number of loads the analysis may fail with the message:

Description

USER FATAL MESSAGE 2008 (GP3) UNDEFINED GRID **** IN LOADSET **** Avoidance: Increase BUFFSIZE

Known Error

CR 39771

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Optimization/Design Sensitivity - PBEAML requires SOUT=YES If a tapered PBEAML is being designed and the user has a value of NO for one of the SO stress requests, incorrect sensitivity values will be created. The optimizer will then be unable to make progress. A fatal message may be issued or the job may indicate a hard convergence at design cycle 1. Avoidance: Do not use SO(j) or SO(B) = NO.

Known Error

CR 39772

Product

MSC / MD Nastran

Corrected Version 2001 Abstract Description

Optimization/Design Sensitivity - PCOMP Z0 term is Incorrect in Punch File If a PCOMP with blank Z0 specified is designed in a Design Optimization (SOL 200) run, the punch file incorrectly changes Z0 to -1. Avoidance: The only avoidance is to edit the punch file.

Known Error

CR 39773

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Optimization/Design Sensitivity - PBEAM, PBEAML - UFM 7052, 7197

Description

Solution 200 jobs may fail with USER FATAL MESSAGE 7052 or USER FATAL MESSAGE 7197 when the field name of an intermediate section of a PBEAML is referenced on a DVPREL1 entry. Avoidance: Split a PBEAM with multiple intermediate sections into multiple CBEAM/PBEAML. For the new PBEAMLs, provide properties for end A and B only.

Known Error

CR 39786

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation/QRG - Continuation Entry Replication produces UFM 6721 The "=(C)," immediate continuation format for card replication as defined on page 428 of the v70.5 Quick Reference Guide no longer works. Avoidance:

Description

Use "," instead. For instance, instead of: =(C), , *7, *7, *7, *7, *7, *7, *7 use: , , *7, *7, *7, *7, *7, *7, *7

Known Error

CR 39791

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

DMAP - SDR2 - SFM 3001, Wrong Datablock Position Number The DMAP message: *** SYSTEM FATAL MESSAGE 3001 (SDR2) THE INPUT DATA BLOCK IN POSITION 10 DOES NOT EXIST.

Description may incorrectly identify the missing data block position. Avoidance: Use DBSTATUS before the offending line to verify the status of the input datablocks. Known Error

CR 39806

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Miscellaneous - Missing "BEGIN BULK" causes part of input to be ignored

Description

Starting with Version 70.7, if an input deck contains a "BEGINBULK" entry (no space between "BEGIN" and "BULK") and the bulk data section contains INCLUDE statements, then bulk data cards that appear BEFORE the "INCLUDE" statement will be ignored.

Known Error

CR 39847

Product

MSC / MD Nastran

Known Error

CR 39847

Corrected Version 2001 Abstract

Documentation/QRG - DCONADD and DCONSTR When the same DCID specified by a DESSUB command is referenced by DCONADD and DCONSTR entries, the constraints defined with the DCONSTR entry are ignored.

Description

Avoidance: Two avoidances exist: 1. Do not reference the same DCID with the DCONADD and DCONSTR entries. 2. If one insists on referencing the same DCID with both entries, include that DCID in the DCONADD entry as the DCONSTR identification number.

Known Error

CR 39885

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Materials - MAT2 - UFM 2042 (EMG) Starting with Version 70.5, if a bulk data file includes PSHELL/MAT2s with 9-digit MIDs where any of the MIDs are greater than 400,000,000 then the deck fails with the message:

Description

USER FATAL MESSAGE 2042 (EMG) MISSING MATERIAL TABLE ****** FOR ELEMENT Such PSHELLs/MAT2s are routinly constructed from the PUNCHed echo of a PCOMP entry but they must not be mixed with other PCOMP entries. The message has been improved in Version 2001.

Known Error

CR 39889

Product

MSC / MD Nastran

Corrected Version 2004 Abstract Description

Distributed Memory Parallel - DMP, EMG - Job Hangs A distributed memory parallel Statics, SOL 101, job will hang if one of the tasks gets a fatal error in EMG. Avoidance: Other than correcting the input there is no avoidance.

Known Error

CR 39892

Product

MSC / MD Nastran

Corrected Version 2001

Known Error

CR 39892

Abstract

DMP - Missing Library - libmpi.so not found The distributed version of MSC.Nastran Version 70.7 on linux requires a file libmpi.so.1. This file was not placed on the CDROM. There are two possible avoidances: 1. The file may be created by using the lam-6.3.1.tar.gz file which is in $MSC_BASE/msc707/linux with the following commands:

Description

configure --with-fflags=-fno-second-underscore --with-shared make install These commands create /usr/local/lam-6.3.1/lib/libmpi.so.1. Please copy this file into $MSC_BASE/msc707/linux. 2. The file may be downloaded from the MSC ftp site from: ftp://ftp.macsch.com/pub/msc-products/NASTRAN/V70.7/linux/ or: ftp.mscsoftware.com/pub/msc-products/NASTRAN/70.7/linux/

Known Error

CR 39896

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Eigenvalue Analysis - READ, EIGRL, RBE3 - SFM 7340 (LNNHERR) Lanczos eigenvalue problems that ran in Version 70.5 may fail in 70.7 with the message: *** SYSTEM FATAL MESSAGE 7340 (LNNHERR) process error reported by subroutine LNNP2CD

Description

Avoidance: This error may be related to the re-formulated RBE3 elements, Setting rotational dof set as independent, appears to be the cause of the problem. If this is the case, either setting: NASTRAN SYSTEM(310)=1 or removing all rotational dof from the independent set may fix the problem.

Known Error

CR 39904

Product

MSC / MD Nastran

Corrected Version 2001

Known Error

CR 39904

Abstract

Superelement - heat transfer - UFM 6599 Superelement heat transfer works in SOL 101 by specifying APP HEAT. However, it only works when there is no convection in the problem. NASTRAN heat transfer applies convection by first defining a boundary element (CHBDYG or CHBDYE) and then applying CONV with the same element ID on that boundary element. For example:

Description

chbdyg,101,,area4 ,5,6,17,16 conv,101,1,,,99 However, there is a limitation in superelements that all element IDs must be unique else the following fatal message is encountered: *** USER FATAL MESSAGE 6599 (SEPUEC) DUPLICATE ELEMENT IDS CONV 101 AND CHBDYG 101 IN SUPERELEMENT 0 0FATAL ERROR Avoidance: Do not use superelements.

Known Error

CR 39931

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

DMAP - FIles Required to Create Delivery Database Missing on NT If you are using Windows NT, the files necessary to create a delivery database are not in the "del" directory.

Description

Avoidance: Contact MSC and request a copy of the necessary files Installed 2001 onto my w2k machine holywell, looks like files are inD:\msc\msc2001\nast\del dir. Ken Winkler

Known Error

CR 39942

Product

MSC / MD Nastran

Corrected Version Abstract

Nonlinear Normal Modes - PARAM,FOLLOWK - Wrong Answers

Description

Using SOL 106 to perform a nonlinear static analysis of a rotating beam with followk effects leads to wrong results when the modes are calculated by restarting with SOL 103 using the NMLOOP parameter. Restarting SOL 106 from a converged solution with just the NMLOOP parameter and a

Known Error

CR 39942 METHOD case control request yields onty the results of the nonlinear static analysis, no normal modes are computed. Avoidance: To get the modes from a restart with SOL 106, add a static subcase with the appropriate values of SUBID and LOOPID set with the NMLOOP parameter and METHOD case control command, then the nonlinear normal modes could be obtained.

Known Error

CR 39962

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Superelements - PARAM,RESVEC - Wrong Answers When using superelements or residual vectors, there is a hard-coded limit of 999 eigenvectors in the program for any single component. If a component has more than 999 modes calculated, the program will incorrectly truncate it to 999 modes with no warning.

Description

Avoidance: Insert the following DMAP alter to remove the limit: compile resvec nolist noref alter 'read.*kzz,mzz','' paraml kzz//'trailer'/1/s,n,zzsize $ READ KZZ,MZZ,,,,,,,,,,,/ ALAMA1,APHX1,MX,OX,EX,/ 'MODES'/S,N,NV////-1/'LAN'////zzsize/0////PRTSUM $

Known Error

CR 39963

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Nonlinear Analysis - CELAS1 - Incorrect Sign

Description

The element force output for CELAS1 in nonlinear solutions has an incorrect sign in MSC.Nastran Version 70.7.

Known Error

CR 39994

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Documentation/QRG - YTAXIS - UFM 676

Description

If the XYPLOT command YTAXIS is used, the program will incorrectly issue

Known Error

CR 39994 UFM 676 indicating that it is not recognized. *** USER FATAL MESSAGE 676 (IFP1XY) YTAXIS IS NOT RECOGNIZED ON ABOVE CARD. Avoidance: Remove the command

Known Error

CR 39995

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation - DLINK - UFM 7011 (DOPR1B) with Concatenated DLINKs The following remark show be added to the DLINK bulk data description in the QRG. i

Description

Remark 6. If a design variable is specified as dependent on a DLINK entry, then it cannot be specified as independent on another DLINK entry.

Known Error

CR 39997

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Static Analysis - PARAM,INREL, REPCASE - UFM 6143 or SFE 4276 in MRGCOL If conventional static solutions are mixed with inertia relief in the same run and REPCASEs are used, the run may fail with UFM 6143 indicating incompatible matrices. This error can also occur in SOLs 105, 200, and all dynamic SOLs with preload capability.

Description

Avoidance: Insert the following DMAP alter: compile sestatic alter 'NSKIP1=NSKIP-1','' nskip1=nskipl-1 $ alter 'NSKIP1=NSKIP-1'(2),'' nskip1=nskipl-1 $ endalter

Known Error

CR 40001

Product

MSC / MD Nastran

Corrected Version Abstract

Optimization/Design Sensitivity - SDAMPING - Wrong Answers

Description

The BHH value for modal damping is computed as Bi = 2 * Mi * (omega) *

Known Error

CR 40001 (zeta) . Mi and omega can vary with the design variable and therefore affect the modal damping sensitivity. However, these perturbations are ignored in the current sensivity analysis with ANALYSIS = MFREQ. The discrepancy associated with neglecting this term is most pronounced at resonant peaks. Avoidance: Alternative forms of damping, such as PARAM G, cvisc and cdamp elements and material damping are supported and could be substituted for the modal damping input.

Known Error

CR 40007

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Distributed Memory Parallel - SUPER - Fails in DISFBS

Description

A distributed memory parallel job with SUPER Case Control commands will fail in DISFBS. Version 2001 traps this invalid input earlier in SEQP and issues the following fatal message *** USER FATAL MESSAGE 7567 (SEQP) THE SUPER CASE CONTROL COMMAND HAS BEEN SPECIFIED. USER INFORMATION: THE SUPER COMMAND IS NOT PERMITTED WITH THE AUTOMATIC MODEL PARTITIONER. USER ACTION: CONSOLIDATE AND REWRITE THE SUBCASES WITHOUT THE SUPER COMMAND.

Known Error

CR 40008

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Case Control - K2GG, K2PP, M2GG, M2PP, P2G - Unexpected Answers DMIG entries are selected by the K2GG, M2GG, P2G, and K2PP, M2PP case control commands. If a case control command selects a bulk data DMIG entry, and there are no DMIG or TF entries in the bulk data file, the module that reads this matrix returns without any error messages, and the run may go to completion although it is missing the selected DMIG information. Avoidance: An avoidance is to put in at least one legal DMIG matrix. The program will provide good diagnostics and a fatal error exit if any selected matrices are missing from bulk data.

Known Error

CR 40037

Known Error

CR 40037

Product

MSC / MD Nastran

Corrected Version GL Abstract

Heat Transfer Analysis - VIEW3D - Wrong Answers The View factor calculation may have trouble detecting elements when the elements are very close. This may lead to wrong answers.

Description

Avoidance: Decrease the ETOL error estimate from default 0.1 to a small number such as 0.0001 on the VIEW3D bulk data entry , so that the VIEW3D program will go and calculate the view factor using the contour integration method

Known Error

CR 40040

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

P-Elements - TEMP(LOAD), ADAPT - SFM 3003 When the ADAPT module is retrieving the thermal loads to calculate the error estimators, the following fatal error may occur:

Description

*** SYSTEM FATAL MESSAGE 3003 (ADAPT) ATTEMPT TO READ PAST THE END OF A LOGICAL RECORD IN DATA BLOCK ETT (FILE 109) IN SUBROUTINE GETEMP Avoidance: The error appears to occur with multiple element types. Currently the only workaround is to specify temperatures using TEMPD.

Known Error

CR 40077

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

Documentation - DMAP Programmer's Guide - SUBDMAP NOT EXECUTED If a SUBDMAP is called with no output datablocks or parameters, then it may not execute. Symptoms will be missing output and a statement in the .f04 file "SUBNAME NOT EXECUTED." where SUBNAME is the name of the subdmap. Avoidance: Add an output block to the calling sequence, or add a parameter.

Known Error

CR 40088

Product

MSC / MD Nastran

Corrected Version GL

Known Error

CR 40088

Abstract

SSSALTERs - mtacca - Wrong Answres

Description

SSSALTER mtacca.vxxx correctly calculates the rigid-body acceleration terms based on the initial conditions, however it does not include the effect of the initial rigid-body acceleration on the rigid-body velocity and displacement terms. Avoidance: The flexible results are correct. If the relative solution is obtained (positive value of PARAM,RBMODES), the answers are correct..

Known Error

CR 40094

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Transient Response Analysis - K2PP - SFM 3007 (TRD1) If a complex matrix is input using the K2PP command, a transient response run will fail with the message:

Description

*** SYSTEM FATAL MESSAGE 3007 (TRD1) ILLEGAL INPUT TO SUBROUTINE TRD1H Avoidance: Use only real matrices in transient analysis.

Known Error

CR 40127

Product

MSC / MD Nastran

Corrected Version 2001 Abstract Description

Heat Transfer - RADBND - Wrong Answers In a steady state heat transfer analysis if RADBND is used to model the radiation across a gap then wrong answers may result. Avoidance: Use RADBC to model radiation across gap instead of view factor.

Known Error

CR 40133

Product

MSC / MD Nastran

Corrected Version 2001.0.1 Abstract

Frequency Response - TLOAD1, TLOAD2 - Wrong Answers

Description

TLOAD1 and TLOAD2 entries define a time dependent load. In frequency response a Fourier analysis is used to transform the time-dependent load to the frequency domain. The TYPE field on the TLOAD1 and TLOAD2 entry which specifies whether the dynamic excitation is and enforced displacement, velocity, or

Known Error

CR 40133 acceleration, is ignored in frequency response. Avoidance: There is no avoidance.

Known Error

CR 40134

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Miscellaneous - ESTIMATE crashes when PROJ statement is present The estimate program fails when a PROJ file management statement is present.

Description Avoidance: Remove the PROJ statement.

Known Error

CR 40139

Product

MSC / MD Nastran

Corrected Version 2001.0.1 Abstract

Description

DMAP - MATGPR, USET - Bad DOF Labels When USET entries are present in the bulk data section that place degrees of freedom in user defined displacement sets, Form 1 (MATGPR GPL,USET,SIL, ...) usage of the MATGPR module may cause the degree of freedom output identifier code to change from the expected T1/T2/T3/R1/R2/R3 to simply the component direction number (1 thru 6). This will occur when the degree of freedom internal number associated with the grid/components defined on the USET entry is less than the number of grid points in the bulk data. External grid identification numbers and printed matrix values are correct. Only the component code identifiers may be displayed differently. The identifier (whichever one is displayed) is correct. Avoidance: A possible avoidance is to use the second form of the MATGPR module

Known Error

CR 40141

Product

MSC / MD Nastran

Corrected Version 2001.0.1 Abstract

Optimization/Design Sensitivity - Optimizer has difficulty making progress

Description

It has been observed that the Method of Modified Feasible Directions (Method=1 on the DOPTPRM entry) can sometimes fail to provide a better design even

Known Error

CR 40141 though it seems that it should. This occurs in situations when there are many more active constraints than there are design variables Avoidance: The SQP algorithm (Method=3 on the DOPTPRM entry) may make progress in these situations.

Known Error

CR 40156

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Acoustic Analysis - fluid-only models - Missing Acoustic Pressure Output If a model contains only fluid elements then the "COMPLEX ACOUSTIC RESULTS" output will not be printed.

Description

Avoidance: Insert a dummy structural element or the following DMAP alter: compile sedrcvr alter 'fscoup' fscoup=true $ endalter

Known Error

CR 40157

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Nonlinear Analysis - PARAM,BUCKLE,1, RESTART - SFM 6036 Nonlinear buckling analysis by a restart in SOL 106 with param, buckle, 1 will encounter SFM 6036 (divide by zero) if the number of increments for the restart subcase is different from 2 or the bisection is triggered.

Description

Avoidance: Specify INTOUT=YES on the NLPARM Bulk Data entry in the last subcase or insert the following DMAP alter: compile nlstatic alter 'IF ( BUCKLE=2 ) POUTF=1','' if ( buckle>0 ) poutf=1 endalter

Known Error

CR 40158

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Documentation/Rigid Elements - RBE3 - Different Answers

Description

The reformulated RBE3 element in V70.7 can result in large differences in

Known Error

CR 40158 answers between V70.5 and V70.7. This has only been observed on models where rotations have been selected on the connected grid points. The changes are most noticeable when the distances between connected grid points are much greater than 1.0. The changes in answer between versions do not occur when only translations are used for the independent dof. Avoidance: To obtain same answers as in Versions prior to 70.7 set: NASTRAN SYSTEM(310)=1 to use the old RBE3 formulation or do not use rotations on the "connected" grid points on RBE3 elements. The answers will then be identical between v70.5 and later versions.

Known Error

CR 40165

Product

MSC / MD Nastran

Corrected Version 2001.0.3 Abstract

Description

Nonlinear Transient Analysis - NLRGAP, PARAM,TSTATIC, NLTRD2, UWM 5258, SWM 3002 An NLRGAP entry exists in a nonlinear transient analysis with param,tstatic,1 then the job will fail in the nltrd2 module with UWM 5258 and SWM 3002. Avoidance: Other than removing the NLRGAP entry there is no avoidance.

Known Error

CR 40167

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Optimizaton/Design Sensitivity - CBUSH - Wrong Answers on NEC In MSC.Nastran Version 70.7 the NEC system has special code to enhance the performance of design sensitivity tasks that utilize the adjoint method. This code yields wrong answers when there are no coordinate systems in the bulk data file and a CBUSH element is being designed. Avoidance: Add a dummy coordinate system. For small problems where performance is not a large concern, setting PARAM AUTOADJ NO will avoid the problem by avoiding the adjoint method.

Known Error

CR 40171

Product

MSC / MD Nastran

Known Error

CR 40171

Corrected Version 2001.0.1 Abstract

Eigenvalue Analysis - Maxratio Control in READ module is Indirect.

Description

Parameter MAXRATIO is used by the DCMP module in statics analysis to control the degree of near-singularity that is allowed when computing solutions. It is input to the DCMP module with a user parameter. This parameter is not an input to the eigensolver, the READ module, although READ makes tests based on its value. If the DCMP module has not run first the value READ uses is set to 1.E7. If DCMP has run prior to READ the value input by the user for DCMP is also used for READ. Avoidance: DCMP is called in modal analysis when SUPORTs exist, when superelement reduction is used, when residual vectors are computed, and for several other reasons. However, it is not always called before the READ module, that behavior is problem dependent. Look in the .f04 file for the word DCMP before R

Known Error

CR 40184

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Optimization/Design Sensitivity Analysis - PLOADi, CBAR - Incorrect Sensitivitie In solution 200, sensitivities are incorrect if a distributed load is applied on CBAR and/or CBEAM elements and there are more than one design variable.

Description

Avoidance: There is no avoidance

Known Error

CR 40228

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Superelements - CSUPER - Floating Point Exception in SEP1X A model bringing in an external superelement may fail with a floating point exception in module SEP1X if the GRID points defined on the EXTRN entry do not exist. Avoidance: Always make sure that the GRID points on the EXTRN entry exist in the model.

Known Error

CR 40257

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Dynamic Analysis - PARAM,RSPECTRA, STATSUB - UWM 4568 (INTERR) Response spectra analysis does not work with prestressing (STATSUB Case Control command). If attempted the following message is issued: .*** USER WARNING MESSAGE 4568 (INTERR) THE NUMBER OF SPECTRUMS SELECTED ON THE, DLOAD CARD DOES NOT MATCH THE NUMBER OF SUPPORT POINTS., CALCULATIONS FOR THIS SUBCASE TERMINATED.

Description

Avoidance: Insert the following DMAP alter: compile semodes alter 'call postreig'(,-1) call dbstore casem,,,,//0/0/' '/0 $ compile postreig list alter 'equivx ' call dbfetch /casem,,,,/0/0/0/0/0 $ PA

Known Error

CR 40261

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Description

Documentation/QRG - Part Superelements - PARAM,OUNIT2 is ignored The Nastran Quick Reference Guide indicates that PARAM,OUNIT2 may be specified in either the Case Control or the Bulk Data. If it is specified in the Bulk Data after a BEGIN SUPER entry it will be ignored. Avoidance: Specify the parameter in the case control..

Known Error

CR 40263

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Description

Transient Response Analysis - EPOINTS, PARAM,ADSTAT - UFM 6143 If a model has EPOINTs and PARAM,ADSTAT is specified on a pre-stressed structure in a modal transient response analysis, the run will fail with UFM 6143 indicating that incompatible matrices were attempted to be merged.

Known Error

CR 40263 Avoidance: Insert the following alter: compile super3 alter 'append.*freq0,mass' if(n1nruh1)then $ type parm,,i,n,ted1 $ ted1 = n1 + 1 $ matgen ,/vone2/6/ted1/1/n1 $ merge ,,f0m,,,,vone2/f0m1/1 $ $ else $ n1=nruh1 $ alter 'merge.*f0m,,,,vone' endif $

Known Error

CR 40275

Product

MSC / MD Nastran

Corrected Version 2001 Abstract Description

DMAP - MATMOD Option 20 - Wrong Answers If the first input to MATMOD Option 20 is purged, then wrong answers result. Avoidance: Rearrange the inputs so that the first input is never purged.

Known Error

CR 40276

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Restarts - SCR=MINI - UFM 2071 in DPD In any dynamic solution with static loads used to define dynamic loads, if the initial run is made using SCR=MINI, the restart run may fail with the following message: *** USER FATAL MESSAGE 2071 (DPD2) will be issued indicating that the DAREA set is not defined.

Description

Avoidance: Insert a dummy DAREA or the following DMAP alter in the restart run only: compile (insert main subdmap name; e.g., sedtran for SOL 109, sedfreq for SOL 108, semfreq for SOL 111, semtran for SOL 112) alter 'dpd ',''

Known Error

CR 40276 DPD DYNAMICS,GPLS,SILS,USET,,/GPLD,SILD,USETD, TFPOOL,,PSDL,,NLFT,TRL,EED,EQDYN/ -1/S,N,LUSETD/0/0/0//0/0/1/123/S,N,NOUE $ endalter

Known Error

CR 40280

Product

MSC / MD Nastran

Corrected Version GL Abstract

Nonlinear Analysis - CBUSH, PBUSHT ,CBUSH1D, PBUSH1D - SFM 3003 In SOL 106, the use of CBUSH or CBUSH1D elements with a nonlinear forcedeflection with a lot of zero slope around the origin may lead to the following unclear fatal message SYSTEM FATAL MESSAGE 3003 (NLITER) ATTEMPT TO READ PAST THE END OF A LOGICAL RECORD IN DATA BLOCK MESTNL (FILE 208) IN SUBROUTINE NLINIT

Description

This is due to the fact that all the nonlinear stiffness is zero for this iteration. This should rarely occur-usually with single element decks. If it does add a dummy nonlinear element that will never have a zero slope as for example: $ put in a mnl dummy element $23456789 0 CBUSH 6666 333333 777777 888888 PBUSH 333333 K .1 PBUSHT 333333 KN 1212 TABLED1 1212 -2.3 -9.-9 0.

Known Error

CR 40296

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Description

Optimization/Design Sensitivity - DESPCH - Incorrect Punch File When parameter DESPCH is set to a non-zero value in an optimization task, the updated property entries written in the punch file do not correspond to the current design cycle. In fact, the updated property entries for the previous design cycle will be written. Avoidance: use the following dmap alter where the original inputs of ept, geom2 and mpt are replaced by eptn, geom2n and mptn.

Known Error

CR 40296 compile desopt alter 'dom12 '(2),'dom12 '(2) DOM12 XINIT,XO,CVALO,PROPIF,PROPOF,OPTPRMG,HIS,DESTAB, geom1n,coordo,,,eptn,geom2n,mptn,epttabf,dvptabf,,,,,,,/ HISADD,NEWPRM,,NEWDES/ DESCYCLE/OBJIN/OBJOUT/S,N,CNVFLG/cvtyp/OPTEXIT// MDTRKFLG/DESPCH/DESPCH1/MODETRAK/eignfreq// PROTYP///fsdcyc $

Known Error

CR 40307

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

DMP - UFM 4276 EC 923, Infinite loop on master+slave(s)

Description

In a DMP (distributed memory parallel) analysis if a slave runs out of disk space then the job may hang and become caught in an infinite cpu loop.

Known Error

CR 40310

Product

MSC / MD Nastran

Corrected Version 2001 Abstract Description

Optimization/Design Sensitivity - DSAPRT If a design variable has more than 6 digits in its id, the formatted sensitivity output will replace the design variable id with ******. Avoidance: Do not use design variables with more than 6 digits in the id.

Known Error

CR 40315

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Documentation - DMAP Module Dictionary - DIAGONAL The DMAP Module Dictionary description of the DIAGONAL Module's WHOLE option is incorrect for complex matrices.

Description

In case of a complex matrix, the option WHOLE gives the following result: POWER = 1.: Magnitude of the complex matrix elements POWER != 1.: The real part of the complex matrix element is raised to the power

Known Error

CR 40358

Product

MSC / MD Nastran

Known Error

CR 40358

Corrected Version 2001 Abstract

Acoustic Analysis - PACABS - Possible Unexpected Results

Description

SYNTH=-YES requests the calculation of B, K, and M from the specified tables. However if a value is given for B, K, or M on the PACABS entry, then any table input is ignored and the data in the B, K, and M fields is used. If SYNTH is specified as NO and no data is specified for B, K, or M then TIDi is used.

Known Error

CR 40394

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

GPFORCE - GPFDR, DEFORM, REPCASE, TEMP - Wrong Answers

Description

Grid Point Force gives incorrect answers when thermal (TEMP) loads are combined with DEFORM loads in the same subcase.

Known Error

CR 40395

Product

MSC / MD Nastran

Corrected Version GL Abstract Description

GPFORCE - GPFDR, CQUAD8 with thermal loads - Wrong Answers The applied load may be incorrect for Grid Point Force output when thermal loads are applied to CQUAD8 elements. Avoidance: There is currently no avoidance.

Known Error

CR 40399

Product

MSC / MD Nastran

Corrected Version 2001 Abstract

Optimization/Design Sensitivity - DRESP1,RTYPE=ESE - UFM 1126 (GNFIST) If RTYPE=ESE is specified on the DRESP1 entry then the job may fail with USER FATAL MESSAGE 1126.

Description

Avoidance: compile respsen alter 'IF ( DOWTVOLD\1 and fdmodes ) jump endloop $ endalter Known Error

CR 41437

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Frequency Response - PARAM,DFREQ - Missing Frequencies Parameter DFREQ is used to determine how the program will filter the loading frequencies to remove apparent duplications. This parameter is ignored in SOL 108, which may result in unintentional removal of desired loading frequencies.

Description

Avoidance: Insert the following alter in your file: compile sedfreq alter 'frlgen ','' type parm,nddl,rs,y,dfreq $ frlgen dynamics,,/frl0,frli///dfreq $ endalter

Known Error

CR 41458

Known Error

CR 41458

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Utilities - RCOUT2 - INTERNAL ERROR: buf_next: bad fileposition

Description

RCOUT on the NT will not work with files larger than 2gb. This limitation has been removed in Version 2003.

Known Error

CR 41490

Product

MSC / MD Nastran

Corrected Version 2001.0.1 Abstract

Aerodynamic Analysis - No Splines - Poor message, SFM 3001 or UFM 1126 If an aero model has no splines to the structure then: 1. In V70.7, SFM 3001 will be issued for data block KRZX.

Description 2. In V70.5, SFM 1126 will be issued for data block WGJ. Avoidance: There is no avoidance Known Error

CR 110595

Product

MSC / MD Nastran

Corrected Version 2004.0.3 Abstract

Superelements - SELOC, POINT - UFM

Description

POINT entires can not be used to locate a superelement (on the SELOC entry). If attempted the run will fail. Avoidance: User GRID entries instead of POINT entries.

Known Error

CR 110850

Product

MSC / MD Nastran

Corrected Version 69 Abstract

Description

P-Elements - Missing Output, Incorrect Labels The triangular shellp elements produce incorrect point ids in the displacement output. Also, stress and displacement output is missing for certain elements in the patran op2 file.

Known Error

CR 1-11YIK

Product

MSC / MD Nastran

Known Error

CR 1-11YIK

Corrected Version 2001.0.3 Abstract

Optimization/Design Sensitivity - PBARL, PBEAML, DVPREL2 - Wrong Answers An optimzation task may produce wrong design sensitivity coefficients when it meets the following conditions:

Description

1) pbarl or pbeam properties are designed; 2) a DVxREL2 entry is presented. Avoidance: use PBAR/PEAM to replace PBARL/PBEAML.

Known Error

CR 116498

Product

MSC / MD Nastran

Corrected Version Abstract

SOLVIT - BICILL and System Cell(241)=2000 - Traceback in SBUT5 The tpl deck it101err when modified to request SYSTEM CELL(241)=2000 and PRECOND=BICILL on the ITER bulk data entry, crasehd with the following traceback: Trap encountered: SIGTRAP - Trace trap FP division by zero Traceback:

Description

Offset 0x0000002c in procedure sbut5_ Offset 0x0000100c in procedure sbvrd_ Offset 0x00000c50 in procedure sitdr3_ Offset 0x00000628 in procedure solvit_ Offset 0x000005a0 in procedure xsem07_ Offset 0x00000964 in procedure mainal --- End of call chain ---

Known Error

CR 116508

Product

MSC / MD Nastran

Corrected Version 2007.0.0 (MD R2) Abstract

Description

Submittal - ESTIMATE - fails with NASTRC=yes in a protected directory If estimate is run in a protected directory and NASTRC is either not specified or specified to yes, then the following error occurs: mayotte msc705t2 estimate smaop ESTIMATE - (Version 70.5 Mar 16 1998 07:19:15)

Known Error

CR 116508 *** USER FATAL MESSAGE (nastran.validate_common_keywords) out=./smaop (program default) Alternate output file prefix. If the prefix is a directory, "/" is appended. The default is "out=./". This directory exists, but is not writable. *** SYSTEM FATAL MESSAGE (estimate.get_nastran_values) No usable data was returned by the nastran command: /msc/msc705t2/solaris/nastran -o smaop whence=bpool,buffsize,memory,real,realdelta,smemory,version *** Mar 19 1998 7:47AM *** Joe Griffin ***

Known Error

CR 1-1R8S9

Product

MSC / MD Nastran

Corrected Version 2001.0.3 Abstract

Cyclic Symmetric Buckling - STATSUB - UFM 1126 in CYCLIC3 When running pre-stiffened modes in cyclic symmetry SOL 115 or buckling with SOL 116, using STATSUB, if scr=no is used, UFM 1126 in CYCLIC3 is issued. Avoidance: Either run with scr=yes or use the following alter for both SOL 115 and SOL 116.

Description

COMPILE CYCBUCKL ALTER 'CYCLIC3'(,-1) DELETE /KKK,,,, $ COMPILE CYCMODE ALTER 'CYCLIC3'(,-1) DELETE /KKK,,,, $ ENDALTER

Known Error

CR 121710

Product

MSC / MD Nastran

Corrected Version 2007.0.1 Abstract

Direct Frequency Response - ITER - Incorrect Results for frequency of 0.0.

Description

Iterative solver produces incorrect results for zero frequency.

Known Error

CR 124542

Product

MSC / MD Nastran

Known Error

CR 124542

Corrected Version 2010.1.0 (MD R4) Abstract

Distributed Memory Parallel - Poor Message, SFM 7402 (DFMFRD) When using DMP, if each processor does not have at least one internal and one external dof, then the job will stop with the following messages:

Description

DFMSA: ICOMP= 1 *** SYSTEM FATAL MESSAGE 7402 (DFMFRD) ERROR DURING NUMERIC ASSEMBLY OF MATRIX ROWS. USER ACTION: PLEASE CONTACT MSC.SOFTWARE CLIENT SUPPORT. 0FATAL ERROR Avoidance: Do no use dmp on small models.

Known Error

CR 125213

Product

MSC / MD Nastran

Corrected Version Abstract

Distributed Memory Parallel - MSC.Monitor (xmon=yes) does not work with dmp.

Description

MSC.Monitor (xmon=yes) does not work with distributed memory parallel jobs.

Known Error

CR 125393

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Description

Optimization/Design Sensitivity - EIGC - Poor Answers Any method other than complex Lanczos will not produce left-hand eigenvectors of sufficient accuracy to yield reasonable complex eigenvalue sensitivities. If another method is requested the job should issue a USER FATAL MESSAGE recommend. UFM 7629 (DOPR3) issued if method on EIGC is not CLAN or HESS. 3/28/02 gdc

Known Error

CR 125588

Product

MSC / MD Nastran

Corrected Version GL Abstract

Superelements - multi-MASTER restart - UFM 3046 (TRD1)

Description

A multi-MASTER residual structure run may fail and issue USER FATAL MESSAGE 3046.

Known Error

CR 125588 Avoidance: If this fatal message is encountered add the following commands into the Case Control: SET 99=0 SELR=99 SELG=99 Else, insert NASTRAN OLDDAREA=0 above the FMS and Executive section

Known Error

CR 126109

Product

MSC / MD Nastran

Corrected Version 2001.0.9 Abstract

Frequency Response Analysis - ESE - Missing Last Freq Output If element strain energy output is requested in frequency response analysis in MSC.Nastran V2001 the output for the last frequency may be missing.

[Joe M - May 2010] Sol 111 ESE testing on v2001.0.7 & 2001.0.9 can't produce error. Appears to have occurred in initial v2001.0.0 release, and there was substantial ESE work (CR 126066) for v2001.0.4. Don't have access to any v2001.0.0 to re-produce error. No reports in last 9 years of any freq resp ESE error of this sort. Assume fixed. Avoidance: To get the ESE for all the frequencies a subcase for each frequency must be created and one extra dummy subcase must be added. An example follows: Description

DISP(PLOT,PUNCH)=ALL SUBCASE1 FREQ = 40 ESE(PLOT,PUNCH)=ALL SUBCASE 2 FREQ = 41 ESE(PLOT,PUNCH)=ALL SUBCASE 3 FREQ = 42 ESE(PLOT,PUNCH)=ALL SUBCASE 4 [Joe M - May 2010] Sol 111 ESE testing on v2001.0.7 & 2001.0.9 can't produce error. Appears to have occurred in initial v2001.0.0 release, and there was substantial ESE work (CR 126066) for v2001.0.4. Don't have access to

Known Error

CR 126109 any v2001.0.0 to re-produce error. No reports in last 9 years of any freq resp ESE error of this sort. Assume fixed.

Known Error

CR 1-296X7

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Description

Performance/Nonlinear Analysis - Poor performance in SOL 106 with superelements If superelements are present, then SOL 106 executes subdmap XSEDRDR which may take an excessively long CPU time to complete. Module xsedrdr is no longer executed in v2004

Known Error

CR 1-2M26V

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Description

nlinear Analysis - GPFORCE, NLPCI - UFM 4276 EC 3102 QOPEN In Version 2001 a request for GPFORCE output in a nonlinear run that uses arc-length methods specified on the NLPCI entry may result in USER FATAL MESSAGE 4276 EC 3102. Avoidance: Other than removing the GPFORCE request or NLPCI, there is no known avoidance.

Known Error

CR 1-2WTGH

Product

MSC / MD Nastran

Corrected Version 2001.0.4 Abstract

Elements - CQUAD4 - Wrong Answers for STRAIN(FIBER,BILIN) option

Description

New QUAD4 element formulation (V70.7+) gives wrong answers for strain(fiber,bilin) at corner GRIDS. V70.5 and earlier gives correct answers. Avoidance: Set NASTRAN SYSTEM(173)=2 to get the pre-V70.7 formulation.

Known Error

CR 1-2706201

Product

MSC / MD Nastran

Corrected Version 2001.0.3 Abstract

Optimization/Design Sensitivity - DMIG - Adjoint Method Produces Wrong Answers

Description

If any of the mass damping or stiffness matrices are not symmetric, results

Known Error

CR 1-2706201 obtained using the adjoint sensitivity analysis will be in error. Asymmetry is typically introduced via user input matrices that are not asymmetric. Acoustic matrices generated in MSC.Nastran are handled correctly and do not have this error. Avoidance: Setting PARAM AUTOADJ NO forces the direct senisitivity analysis and avoids the error. A dmap alter in the attachment corrects the error while using the adjoint method. Fix taken in r30

Known Error

CR 1-2754601

Product

MSC / MD Nastran

Corrected Version 2001.0.3 Abstract

Description

Aeroelastic Analysis - Mach label in Aerodynamic Force Output is Incorrect The AEROF request in SOL 146 produces a table which always indicates MACH=0.00000, regardless of the Mach number used in the analysis. If there is a single Mach number input with the MKAEROi entries, then only the label is wrong. With multiple Mach numbers, the print will be based on the lowest Mach number and the data will be in error if the analysis has been performed at other than the lowest Mach number. Avoidance: The following dmap alter produces the correct Mach number print: compile seaero alt

Known Error

CR 1-2771301

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Postprocessing - Formatted OUPUT2 File causes excessive SWM 1204 (UNRTN) When Nastran is writing a formated op2 file for certain large models, it creates thousands of warning message:

Description

*** SYSTEM WARNING MESSAGE 1204 (UNRTN) ABSOLUTE VALUE OF SINGLE PRECISION VALUE IS LESS THAN THE MINIMUM FILTER OF 1.0E-37, AND WILL BE RESET TO THE CORRECTLY SIGNED FILTER VALUE

Known Error

CR 1-2804804

Product

MSC / MD Nastran

Corrected Version 2001.0.3 Abstract

Description

Elements - QUAD4, TEMP(LOAD) - Wrong Answers The new skewed QUAD4 element formulation introduced in Version 70.7 may yield incorrect answers for static analyses with thermal loads. Avoidance: The version 70.5 formulation may be requested by setting SYSTEM(173)=2.

Known Error

CR 1-2859001

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

DMAP - Poor Message, UFM 404

Description

The DMAP compiler gives a bad message, when a "/" delimiter is used instead of a ",". The message is UFM 404 (CTYPE) "A NON-RIGHT PARENTHESIS DELIMITER WAS DETECTED WHERE A RIGHT PARENTHESIS DELIMITER IS REQUIRED".

Known Error

CR 1-2883605

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Acoustic Analysis - ACSRCE, RLOAD1, DPHASE, DELAY - Wrong Answers DPHASE and DELAY functions on fluid loads with ACSRCE and RLOAD1 entries give incorrect delays in Version 2001 leading to wrong answers.

Description Avoidance: Use RLOAD1 with TD and TC combinations for phasing.

Known Error

CR 1-2971701

Product

MSC / MD Nastran

Corrected Version 2001.0.9 Abstract

Cyclic Symmetry - CYSUP with differential stiffness - maxratio errors The CYSUP entry is ignored in the static analysis part of SOLs 115 and 116. This may lead to maxratio errors.

Description

Avoidance: There is no Avoidance. This was fixed for version 2001

Known Error

CR 1-2994320

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Dynamics - LOADSET/LSEQ - Poor Message, UFM 4603

Description

If there is a LOADSET request in the Case Control and no LSEQ entries in the Bulk Data but other static load entries with the same id , the program terminates the job with a very confusing USER FATAL MESSAGE 4603. The program should terminate the job with the more appropriate UFM 4390.

Known Error

CR 1-2994324

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

DMAP - ORTHOG Module - Incorrect Matrix Trailers may lead to various fatal messages

Description

If the ORTHOG module is used to generate the Q and R output matrices for a rectangular matrix A using parameter values of IOPT=1 and ICON=0, the R output matrix, which is an upper traingular matrix, is generated with wrong trailer values. This causes a fatal error if this matrix is subsequently used in a module like MPYAD.

Known Error

CR 1-2999801

Product

MSC / MD Nastran

Corrected Version 2001.0.3 Abstract

Parallel Methods - DOMAINSOLVER ACMS - SE Commands Cause Failure In ACMS case control superelement commands such as SEALL=set will cause ACMS to fail. Avoidance: Comment out all superelement case control commands in runs using DOMAINSOLVER ACMS.

Description

Note that SEQP removes SUPER records from case control. Fatal messages takes the form: *** SYSTEM FATAL MESSAGE 4252 (SEMA) MATRIX XAAV FOR UPSTREAM SUPERELEMENT XX DOES NOT EXIST. where XX is some upstream SE number.

Known Error

CR 1-3011601

Product

MSC / MD Nastran

Corrected Version 2001.0.3

Known Error

CR 1-3011601

Abstract

Nonlinear Transient Analysis - LOADSET - Wrong Answers When a static load set is specified in SOL 129 in version 2001, incorrect result may be produced if: (1) The LOADSET case control command and LSEQ bulk data entries are omitted (an enhancement supported by v2001); and

Description

(2) At least one of the following static loads is referenced by the field of DAREA in TLOADi (i=1,2) bulk data card. They are FORCE1, FORCE2, MOMENT1, MOMENT2, PLOAD, PLOAD4 and PLOADX1. Avoidance: Always use the LOADSET case control command and the LSEQ bulk data entries to specify static loads in nonlinear transient analysis (SOL 129) if the type of static loads is a follower force.

Known Error

CR 1-3012601

Product

MSC / MD Nastran

Corrected Version GL Abstract

Nonlinear Transient Analysis - OLOAD - OLOAD output may not include follower force effect.

Description

In Version 2001, the OLOAD output does not include the follower force effect in SOL 129 when static loads are selected but the case control command LOADSET and bulk data entry LSEQ are omitted. This is a cosmetic problem that will not affect the other results.

Known Error

CR 1-3036805

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Description

Documentation - Missing Documentation for Heat Transfer in P-Elements P-Elements were extended to support heat transfer analysis in MSC.Nastran Version 70.7. The Quick Reference Guide was not issued for 70.7 and the updates have not been added to the 2001 QRG. Avoidance: If you are interested in this capability contact support and the documentation will be provided.

Known Error

CR 1-3063705

Product

MSC / MD Nastran

Known Error

CR 1-3063705

Corrected Version GL Abstract

Distributed Memory Parallel - DOMAINSOLVER, GDMODES, SEQP - No Message If a user attempts to submit a model with superelements in SOL 103 with geometric domain Lanczos the job will fail in the SEQP module and will not issue a meaningful message.

Description Avoidance: This is a limitation. References to superelements must be removed from the model. Known Error

CR 1-3068607

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Optimization/Design Sensitivity - Senstivities of PBEAMLs that include warping may be incorrec Sensitivities of warping coefficients are ignored in the design of PBEAML section types. The effect of this is that warping coefficients are unchanged from their initial value thereby creating wrong answers when these effects are significant.

Description

Avoidance: An awkward avoidance is to design equivalent PBEAM properties using DVPREL1 and DVPREL2 entries. The SA and SB points on the CBEAM entry must be grid points for warping sensitivities to be calculated correctly even when the PBEAM entry is used. Otherwise, it is suggested that if the PBEAML is used, the final PBEAML design be submitted in a new run to see if the neglected warping effects are significant.

Known Error

CR 1-3068612

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

Aeroelastic Analysis - AMP - SFM LAJJT Matrix Not Available If multiple aero methods such as strip theory and the doublet lattice method are used in the same run, the AMP module will produce a message that the LAJJT matrix is not available. Avoidance: Do not run multiple aero methods in the same run or run in a Version 70 or earlier system.

Known Error

CR 1-3103909

Product

MSC / MD Nastran

Corrected Version 2001.0.3

Known Error

CR 1-3103909

Abstract

Optimization/Design Sensitivity - DRESP1 - SFM 3003

Description

The above fatal message can occur when spc forces or element strain energy responses are used in conjunction with grid responses. The problem is caused because the code incorrectly thinks that adjoint sensitivity method is appropriate and subsequent calculations produce incompatible datablocks. Avoidance: Set PARAM AUTOADJ NO to preclude the selection of adjoint senstivity analysis.

Known Error

CR 1-3151101

Product

MSC / MD Nastran

Corrected Version 2001.0.3 Abstract

Description

Optimization/Design Sensitivity - Adjoint Method with Inertia Relief yields Wrong Answers Sensitivity analysis results are in error for a statics analysis with inertia relief when the program selects the adjoint method for the sensitivity analysis. Avoidance: Set PARAM,AUTOADJ,NO to force the direct sensitivity method.

Known Error

CR 1-3151106

Product

MSC / MD Nastran

Corrected Version 2001.0.3 Abstract

Optimization/Design Sensitivity - Gravity effects ignored in adjoint method if PARAM,CDIF,YES The adjoint senstivity calculation ignores the sensitivity of any gravity loads when the PARAM,CDIF.YES is used to specify central difference based element perturbations.

Description Avoidance: Set PARAM,CDIF,NO (the default for property optimization) or obtain a DMAP alter from client support.

Known Error

CR 1-3159901

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Distributed Memory Parallel - DMP - SFM 3001 (DISUTIL)

Description

Small models, demonstration problem v10101.dat with dmp=2 is an example, that are submitted with dmp may fail with SFM 3001 (DISUTIL) THE INPUT

Known Error

CR 1-3159901 DATA BLOCK NAMED QGHD DOES NOT EXIST. The problem is that the partitioner is not able to partition the model into as many domains as desired. Usually this does not cause a problem and the job continues serially. Other jobs that enter the following line in subdmap sedrcvr will have the problem: "if ( prtreslt='yes' and noqg>-1) then .. ) Avoidance; Don't run dmp on small jobs.

Known Error

CR 1-3162504

Product

MSC / MD Nastran

Corrected Version 2001.0.3 Abstract

Description

Optimization/Design Sensitivity - APRCOD=3 - Inaccurate Gradients APRCOD=3 in design optimization approximates the constraint values using the the most conservative prediction on the change in the constraint due to a change in a design variable. The constraints calculated in this fashion are computed correctly, but the gradient of these constraints can be computed incorrectly. Avoidance: Use another APRCOD value (1 or 2). Internal testing has not revealed a case where the incorrect computation has produced a difference in the final design.

Known Error

CR 1-3209214

Product

MSC / MD Nastran

Corrected Version 2001.0.6 Abstract

Dynamics - MEFFMASS - Missing Output It has been observed on some problems that the output for the TOTAL EFFECTIVE MASS FRACTION SUMMARY is missing in some of the directions.

Description Avoidance: Divide the appropriate diagonal term of the EFFECTIVE MASS MATRIX by the corresponding RIGID BODY MASS diagonal term. Known Error

CR 1-3209224

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Optimization - PARAM,EIGD,YES - SFM 6920

Description

If eigenvector sensitivity is requested (PARAM,EIGD,YES) and there is design variable linking (DLINK), then the job may fail with messages similar to

Known Error

CR 1-3209224 the followin: *** SYSTEM FATAL MESSAGE 6920 (MATMOD) FOR MATMOD OPTION 1, THE COLUMN NUMBER 3 IS INVALID. IT MUST BE GREATER THAN ZERO AND LESS THAN 3. Avoidance: Insert the following dmap alter: compile eigvecds list alter 'L XINIT','' PARAML DESTAB//'TRAILER'/2/S,N,NDB $

Known Error

CR 1-3297102

Product

MSC / MD Nastran

Corrected Version GL Abstract

Complex Lanczos - EIGC - UFM 6138 In a complex eigenvalue problem using complex lanczos, if insufficient memory is available for sparse fbs, then the following messages will be issued: *** USER FATAL MESSAGE 6138 (UDSFBI) INSUFFICIENT CORE FOR SPARSE FBS USER ACTION: INCREASE CORE BY 1002 WORDS

Description

However, increasing the MEM keyword may not increase the allocated memory. Avoidance: Use one of the following avoidances. 1. Add nastran system(108)=512 to use the QZ HESS method. 2. Add nastran system(108)=2 to use the old complex Lanczos 3. Add nastran system(108)=131072 to the input file

Known Error

CR 1-3354804

Product

MSC / MD Nastran

Corrected Version 2001.0.4 Abstract

Installation - NT Only - New FlexLM server on NT is missing .dll file

Description

The new FlexLM license server (V7.0) delivered with Nastran V2001 on Windows NT is missing a .dll file that allows the FlexLM GUI (from the Control Panel icon) to check the license server status. Picking on the "Status" button

Known Error

CR 1-3354804 on the NT FlexLM GUI results in a message that it is "unable to obtain status due to missing lmgr326a.dll The same message appears when you choose the HostID button to find out the current FlexLM HostID.

Known Error

CR 1-3379914

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Optimization - PBEAML/PBARL - Incorrect Sensitivity Coefficients In an optimization/sensitivity analysis, if the model contains PBEAML or PBARL entries, then the eigenvector sensitivity coefficients will be incorrect.

Description

V2004 supports 6 new response types in sol 200 for eigenvector sensitivity. The responses must be specified on the DRESP1 entry, specifying param,eigd,yes will not activate this capability. This addresses this error in v2004.

Avoidance: Replace the PBEAML or PBARL entry with the equivalent PBEAM or PBAR entry. Known Error

CR 1-3414201

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Documentation/QRG - TEMP(INIT), TEMP(LOAD)

Description

Table 4-3 in Section 4A of the Quick Reference Guide indicates that TEMP(INIT) is not supported in SOL's 101, 103, and 105, 107, 108, 109, 110, 111, and 112. TEMP(INIT) may be used in SOLs 103, 107, 108, 109, 110, 111, and 112 if STATSUB is used to define the initial temperature. Likewise TEMP(LOAD) may be used in SOLs 103, 107 and 110 if STATSUB is used.

Known Error

CR 1-3422001

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Documentation/QRG - PARAM,INREL,-2 - Missing Documentation The documentation for PARAM,INREL,-2 is missing from the QRG.

Description

The value of param, inrel, -2 provides an inertia relief analysis in SOL 101 without the need for a SUPORTi entry. Remove all such entries. The model must have mass defined. Request TAN 4854 from your client support user documentation and example problems.

Known Error

CR 1-3437715

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

DMAP - TABPRT - NaN in TABPRT output of ONRGY When the ONRGY datablock is printed using TABPRT using the NDDL descriptions, the final -1 is not recognized and is printed as NaN.

Description

compile sedrcvr alter 208 tabprt onrgy1//'onrgy'///1 $ endalter

Known Error

CR 1-3439701

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Description

Optimization/Design Sensitivity - DESGLB, DESSUB - Wrong Answers for Superelement Optimization When a superelement optimization job includes a DESGLB (or DESSUB) command that references a constraint defined by either a volume response or weight response with ATT1=ALL, the contraint values for each SE, along with the one for the whole model are presented to the optimizer which may lead the optimizer to reach a wrong conclusion. Avoidance: There is no avoidance.

Known Error

CR 1-3451401

Product

MSC / MD Nastran

Corrected Version 2001.0.3 Abstract

Nonlinear Analysis - GPFORCE - Missing Output In a SOL 106 run, if grid point force is requested, and the model contains more than one linear element type and thermal loadings are applied, then the following fatal message will be issued.

Description

*** SYSTEM FATAL MESSAGE 3007 (GPFDR) ILLEGAL INPUT TO SUBROUTINE GPFTDL Avoidance: Other than having only one linear element type, there is no known avoidance.

Known Error

CR 1-3458801

Product

MSC / MD Nastran

Known Error

CR 1-3458801

Corrected Version GL Abstract

Nonlinear Transient Analysis - Wrong answers NO>1 w/ AUTO or TSTEP Wrong answers are produced if METHOD=AUTO or TSTEP are specified on the TSTEPNL entry and the NO field (nskip) is > 1.

Description

This error will not be fixed. The functionality of METHOD=AUTO or TSTEP is fully replaced by METHOD= ADAPT. The AUTO and TSTEP methods have been de-documented but are not blocked.

Known Error

CR 1-3477406

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Eigenvalue Analsyis - PARAM,SNORM - SFM 3007 (MERGE) A model containing 59 massless mechanisms failed with SFM 3007 indicating illegal input to MERGE during the eigenvalue solution.

Description

Avoidance: For this model, changing the value of PARAM.SNORM to 0.0 allowed it to run.

Known Error

CR 1-3496527

Product

MSC / MD Nastran

Corrected Version 2001.0.3 Abstract

Description

Modal Frequency Response - ESE - Incorrect Output In a modal frequency response analysis, if element strain energy is requested and a set ID of 2 is used, then erroneous complex acoustic results may be printed, even though there is no acoustic elements in the model. Avoidance: Use a set ID other than 2.

Known Error

CR 1-3507901

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Eigenvalue Analysis - PARAM,RESVEC - Floating Point Overflow in frrd1

Description

Modal frequency response jobs may fail in the frrd1 module with a traceback when param,resvec,yes is specified. Traceback:

Known Error

CR 1-3507901 Offset 0x00001680 in procedure bldpk_ Offset 0x00000790 in procedure frrd1f_ Offset 0x0000215c in procedure sqfreq_ Offset 0x0000000c in procedure freq_ Offset 0x00000124 in procedure xsem10_ Offset 0x00000164 in procedure xsemdr_ Offset 0x0000005c in procedure nastmon_ Offset 0x000009ac in procedure mainal --- End of call chain --Avoidance: Do no specify param,resvec or request fewer eigenvalues.

Known Error

CR 1-3524604

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

SSSALTER - gpftrna alter does not work in modal transient SSSALTER gpftrna.v707 works only in direct transient, not in modal transient.

Description

Avoidance: Change COMPILE SEDTRAN to COMPILE SEMTRAN in the alter or get an updated version from the MSC web page

Known Error

CR 1-3525701

Product

MSC / MD Nastran

Corrected Version 2001.0.3 Abstract

Optimization/Design Sensitivity - DSVG1 - Wrong Answers In design sensitivity (DSVG1), if there is not enough space to hold the solutions in core, the program will hold as many solutions as possible to perform matrix multiplication, then, repeat for the rest of solutions causing wrong results. Avoidance: Increase memory using the following formula:

Description

Minimum memory space to hold all solutions in core = (NSOL * GSIZE * NWORD * NCMP * 4) nsol - number of non-null solution vectors in UG gsize - number of rows in the UG vector NWORD - 2 for short word machine and 1 for long word machine NCMP - 2 for complex number and 1 for real number in UG

Known Error

CR 1-3539967

Product

MSC / MD Nastran

Known Error

CR 1-3539967

Corrected Version 2001 Abstract

Optimization/Aeroelasticity - BC, TEMP, ANALYSIS=SAERO - SFM 1013

Description

Multiple boundary conditions with static aeroelastic optimization and temperature loading results in SYSTEM FATAL MESSAGE 1013. Avoidance: There is no avoidance.

Known Error

CR 1-3543501

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Optimization/Design Sensitivity - Multiple Superelement, Incorrect Complex Eigenvalue Sensitivities

Description

In multiple superelements, the complex eigenvalue sensitivity coefficients are incorrect for the residual superelement (SEID=0). This problem also exists in flutter sensitivity when more than one superelement is in the model. This problem can be avoided with following DMAP alter: compile ceigsens,list $ alter 'EQUIVX CDELK1/CDELK/DMRESD',''(,10) $ IF ( DMRESD0 alter 'lauldx'(3) if ( ncol > 0 ) then $ alter 'lauldx'(5,2) endif $ ncol>0 compile gendv2p

Known Error

CR 1-3743525 alter 'bcdr' PARAML CASE0//'DTI'/s,n,nskip/7//S,N,TEMPLD $ PARAML CASE0//'DTI'/s,n,nskip/6//S,N,DEFORM $ compile xsedrdr alter 'bcdr' (complete alter does not fit in allowed space. See the attachment)

Known Error

CR 1-3745506

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Nonlinear Analysis - Superelements - Missing or Extra Output In nonlinear analysis (SOL 106), if superelements are used, they will use the output requests from the residual structure subcases. Any output requests in the superelement subcases will be ignored.

Description

Avoidance: Insert the following alter into your input file: compile super3 alter 'alter 'IF ( (NOCASRS1>-1','' IF ( NOCASRS1>-1 AND SEID=0 ) THEN $

Known Error

CR 1-3749805

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Elements - ELSUM, PCOMP - SFM 3008 (ELTPRT), Excessve Memory If ELSUM output is requested and the model has composite elements, the run may fail with in ELTPRT or ELTPT4 with a message of the form:

Description

*** SYSTEM FATAL MESSAGE 3008 (ELTPRT) INSUFFICIENT MEMORY AVAILABLE FOR SUBROUTINE PREMAT Avoidance: There is no avoidance other than providing a large amount of memory or not requesting ELSUM output.

Known Error

CR 1-3751401

Product

MSC / MD Nastran

Corrected Version 2004.0.5 Abstract

Post Processing - param,post,0 - Patran can not view postprocess results in the xdb

Description

If a linear heat transfer analysis is followed by a stress analysis in

Known Error

CR 1-3751401 SOL 101, then Patran can only view the temperature output and can not view the displacement output from the xdb. Avoidance: There is no avoidance.

Known Error

CR 1-3754501

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Description

Nonlinear Analysis - param,fksymfac - Difficulty Converging, Follower Forces SOL 106 may diverge with symmetrized follower stiffness as the rotations becomes large. If the effect of asymmetry of the follower stiffness dominates the stiffness, but the default option for param,fksymfac symmetrizes it, then the problem may have convergence difficulty. Avoidance: Set param,fksymfac,0.0.

Known Error

CR 1-3770604

Product

MSC / MD Nastran

Corrected Version 2001.0.3 Abstract

Description

Frequency Response - MEFFMASS - Wrong Answers If modal effective mass output (MEFFMASS) is requested in a frequency response analysis that requests more that 50 modes, than the formatting of the "MODAL EFFECTIVE MASS FRACTION" table will deteriorate and put each additional mode on a new page. Also models with many roots (more than 100) may result in meaningless results being printed to this table. This error has been fixed in Nastran 2001.0.3 except on Cray platforms.

Known Error

CR 1-3771601

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Miscellaneous - NOLIN, NLRGAP - Poor Message

Description

MSC.Nastran issues an incorrect fatal error message when the NOLIN-type Bulk Data entry (including NLRGAP) references an undefined grid point ID.

Known Error

CR 1-3787901

Known Error

CR 1-3787901

Product

MSC / MD Nastran

Corrected Version 2001.0.3 Abstract

Description

Acoustic Analysis - Fluid/Structure Analysis with multiple PANEL bulk data entries - UFM 653 Fluid/Structure analysis using multiple PANEL bulk data entries may fail with a GINO read error. The GP5 module counts EDT PANEL entries incorrectly when there are 3 or more individual PANEL bulk data entries. Avoidance: Use a single PANEL entry to list panel data.

Known Error

CR 1-3788001

Product

MSC / MD Nastran

Corrected Version 2001.0.3 Abstract

P-elements - CORDi - UFM 2025 (VECPLOT) Large p-element models with output displacement coordinate systems may fail in VECPLOT with the following message: error in VECPLOT:

Description *** USER FATAL MESSAGE 2025 (VECPLOT) UNDEFINED COORDINATE SYSTEM ID = 10 Avoidance: A workaround is to increase BUFFSIZE. Known Error

CR 1-3816002

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Case Control - No Warning Message Issue for Invalid Requests

Description

If a case control output request includes unsupported options, there is no warning issued and the request is simply ignored. For example if DISP(POLAR) is specified instead of DISP(PHASE) to get output as magnitude/phase, the output will be real/imaginary and no warning message will be issued.

Known Error

CR 1-3827201

Product

MSC / MD Nastran

Corrected Version 2001.0.6 Abstract

DBC - SWM 6065, DBCMSG Error Message 14

Description

In v70.7, if the geometry datablocks, load datablocks, and the output datablocks are requested on the same DBC call, the job may fail with the following

Known Error

CR 1-3827201 error messages: *** SYSTEM WARNING MESSAGE 6065 (DBC) *** DBCMSG ERROR MESSAGE 14 FROM SUBROUTINE GRIDBK Avoidance: A DMAP avoidance is available that beaks the DBC into two separate calls, one for the geometry and loads, and one for the output datablocks.

Known Error

CR 1-3860101

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Complex Eigenvalue Analysis - OFREQ, OMODES - SFM 6143 (UPARTN)

Description

Using the OFREQ or OMODES feature in modal complex eigenvalue analysis results in SYSTEM FATAL MESSAGE 6143 in the UPARTN module.

Known Error

CR 1-3889242

Product

MSC / MD Nastran

Corrected Version 2001.0.3 Abstract

Case Control - WEIGHTCHECK. CGI=NO - Extra Output

Description

If on the WEIGHTCHECK case control command set is not equal to g, then the CG location, I(S), I(Q), and Q matrices are not printed unless the CGI keyword is set to YES. This is the design intent. The default for CGI is NO. However, if CGI is explicitly set to NO for set not equal to G, then the CG location, I(S), I(Q), and Q will also be printed. For example: weightcheck(set=(n),cgi=no )=yes Avoidance: If this additional information is not desired, leave the CGI keyword out.

Known Error

CR 1-3889601

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Documentation/QRG - GPFORCE - Slideline Forces ignored in the GPFORCE Calculation

Description

Remark 5 of the GPFORCE case Control description in the V2001 QRG needs to be modified to state that Slideline force contributions are ignored in the GPFORCE calculation.

Known Error

CR 1-3948211

Known Error

CR 1-3948211

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Documentation/QRG - PARAM,OMID - Missing Documentation The documentation for parameter OMID is missing from the 2001 Quick Reference Guide. The parameter is documented in the 2001 Release Guide. The documentation should read:

Description

OMID Default=NO To print or punch the results in the material coordinate system, set the parameter OMID to yes. Applicable to forces, strains, and stresses for CTRIA3, CQUAD4, CTRIA6, and CQUAD8. Other elements and outputs are not supported. This capability is not supported by pre-processors (xdb and op2 output are not changed) and grid point stress output that assumes output is in element coordinate systems.

Known Error

CR 1-3961304

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Dynamics - PARAM,RESVEC,YES, SOL 103 -Not Generated

Description

In a SOL 103 run, if the direct load method is used (TLOADi pointing directly to a spatial load, e.g, FORCE entry) instead of the LOADSET/LSEQ combination, then the residual vectors are not generated. Avoidance: If the residual vectors are desired in a SOL 103 run, then use the LOADSET/LSEQ combination

Known Error

CR 1-3961311

Product

MSC / MD Nastran

Corrected Version 2001.0.3 Abstract

Automatic Component Mode Synthesis - RESIDUAL VECTOR, USET,U6 - UFM 2049 If a job employs ACMS, and USET,U6 is used to request a residual vector, then the job will fail with the following error messages:

Description

*** USER FATAL MESSAGE 2049 (GP4) UNDEFINED GRID POINT xx HAS A COORDINATE REFERENCED ON A USET CARD. Avoidance: Use the inertial load method or the applied load method

Known Error

CR 1-3961311 (LOADSET/LSEQ combination)

Known Error

CR 1-3971529

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Elements - CQUAD4 - UFM 4297 Incorrectly Issued for Missing MATi If the PSHELL for a valid-geometry QUAD4 references a non-existent MATi entry, then UFM 4297 (EQD4D) is issued indicating the element has an interior angle greater than 180 degrees. This message is incorrect.

Description

The UFM 4297 is followed by an appropriate UFM 2042 (EMG) that does indicate that the MATi entry is missing. This sequence of messages occurs in both Version 70.7.2 and 2001. In earlier releases (v70 and 70.5), only the appropriate 2042 message is issued. The UFM 4297 message is incorrect/misleading which will increase model debug time for the user and increase support time/cost for MSC. A small test deck demonstrating the problem is attached.

Known Error

CR 1-3975803

Product

MSC / MD Nastran

Corrected Version 2004 Abstract Description

P-Elements - CBEAM, TEMP(MAT) - Wrong Answers For the beam p-elements, the temperatures used for the temperature-dependent material properties are incorrect. Avoidance: There is no avoidance.

Known Error

CR 1-4015495

Product

MSC / MD Nastran

Corrected Version GL Abstract

Heat Transfer Analysis - VIEW3D, CHBDYP - Wrong Answers Bob Harder is looking into it. - Raj

Description

The VIEW3D module gives bad results for the chbdyp,line option for rod structures

Known Error

CR 1-4015495 that span 360 degrees. When there is potential shading where the ERROR=YES, for example 1-18 sees the error,then it will recompute the view factor using contour integration. The error of NASTRAN is that It Does not using the contour integration method,and the view factor 1-18(on the second times) is 0.554. The theory for 1 to 18 using Hottel's String method is 0.02851 *** VIEW FACTOR MODULE *** OUTPUT DATA *** CAVITY ID = 10 *** ELEMENT TO ELEMENT VIEW FACTORS C* PARTIAL SURF-I SURF-J AREA-I AI*FIJ FIJ ERROR SHADING ERROR SCALE 1 - 18 6.5403E+00 6.82983E+00 1.04427E+00 6.8657E+01 NO YES 1 52 6.5403E+00 1.06617E+01 1.63015E+00 2.4993E+02 NO YES 1 18 6.5403E+00 3.62416E+00 5.54126E-01 240/256 1 52 6.5403E+00 1.32828E-01 2.03091E-02

Avoidance: Use the older view module. The older view factor can be selected by commented out the VIEW3D bulk data entry. See attachment :2d_chbdyp_view_dcc_old.dat Known Error

CR 1-4022230

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Elements - CQUAD4, CTRIA3 - Misleading UFM 4297. A missing material entry may cause UFM 4297 (EQD4D) to be incorrectly issued:

Description

QUAD4 ELEMENT WITH ID = 140507 HAS AN INTERIOR ANGLE POSSIBLY GREATER THAN OR EQUAL 180 DEGREES. before issuing a correct message UFM 2042 (EMG) MISSING MATERIAL TABLE 111551 FOR ELEMENT 140507

Known Error

CR 1-4022230 This is misleading when a large number of UFM 4297 are issued before the correct UFM 2042.

Known Error

CR 1-4037006

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Miscellaneous - MPC, blank coefficients - UFM 316 Miscellaneous - MPC, blank coeffiecients - UFM 316 The default for the coefficients of the independent degrees of freedom for an MPC is 0.0. However, if they are left blank, then the job may fail with the following messages:

Description *** USER FATAL MESSAGE 316 (IFPDRV) ILLEGAL DATA ON BULK DATA ENTRY MPC Avoidance: Remove the degrees of freedom that have zero coefficients. Known Error

CR 1-4051301

Product

MSC / MD Nastran

Corrected Version 2001.0.3 Abstract

Elements - CWELD - Incorrect sign of moments in plane 2.

Description

The moments in plane 2 (m_y) of CWELD elements are output with the opposite sign.

Known Error

CR 1-4056201

Product

MSC / MD Nastran

Corrected Version 2001.0.3 Abstract

Elements - CWELD, PWELD - UFM 2042 (EMG) If the CWELD element is used in superelement analysis the job may fail with the message:

Description

*** USER FATAL MESSAGE 2042 (EMG) MISSING MATERIAL TABLE xxx FOR ELEMENT yyy Avoidance: There is no avoidance.

Known Error

CR 1-4056908

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Distributed Memory Parallel - GDMODES, w/multiple BC's - SFM 6143 in DUMERG

Known Error

CR 1-4056908 A sol 103 run w/ multiple subcases having different SPC sets runs in Version 70.7.2 DMP but not Version 2001. More precisely, multiple boundary condition subcases with different s-set size do not run under Geometric Domain Parallel (GDMODES).

Description

The following error results: *** SYSTEM FATAL MESSAGE 6143 (DUMERG) THE SIZES OF THE INPUT MATRICES AND THE DOF SETS ARE INCOMPATIBLE. SPECIFICALLY: The number of rows in PHA1 is not equal to the size of the COMP-set Essentially, when the F-set changes between subcases, an incompatible matrix multiplication with PHA1 is attempted. Multiple BC case works when Domainsolver FDMODES is used.

Known Error

CR 1-4063523

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Description

Superelements - PARAM,SESDAMP - SFM 3001 (GKAM), Wrong Answers If modal damping is requested for PART superelements using PARAM,SESDAMP,YES the run may fail with SYSTEM FATAL MESSAGE 3001 (GKAM) or get incorrect damping. This is due to the program trying to get the TABDMP1 data from the main bulk data. Avoidance: Copy the TABDMP1 entries into the main bulk data section.

Known Error

CR 1-4067301

Product

MSC / MD Nastran

Corrected Version 2001.0.3 Abstract

Miscellaneous - ISHELL module prematurely terminates Nastran

Description

The ISHELL module terminates the Nastran execution if any forked process takes more than about 5 minutes to complete.

Known Error

CR 1-4070108

Product

MSC / MD Nastran

Corrected Version 2001.0.3

Known Error

CR 1-4070108

Abstract

Optimization - PBARLs, PBEAMLs - UFM 6499 In an optimization run, if both PBARL and PBEAML exist in the model, then the job may fail with the following error messages: THE GRADIENT OF CONSTRAINT NUMBER x IS ZERO CONSTRAINT IS REMOVED FROM THE ACTIVE SET ** THIS IS A VIOLATED CONSTRAINT ** A FATAL ERROR WILL BE GENERATED

Description **** ONE OR MORE VIOLATED CONSTRAINTS HAS A ZERO GRADIENT **** NO PROGRESS IS POSSIBLE OPTIMIZATION TERMINATED *** USER FATAL MESSAGE 6499 (DOM9D) Avoidance: Use either all PBARL or all PBEAML or convert them to equivalent PBAR and PBEAM Known Error

CR 1-4082701

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Documentation/QRG - LOADCYN - UFM 4342 (CY1BLD)

Description

A remark needs to be added to the Quick Reference Guide LOADCYN entry that indicates that in cyclic buckling anaysis loads may only be applied to the first segment and only harmonic zero loads may be applied.

Known Error

CR 1-4082801

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Elements - CWELD - Incorrect sign on moment force output.ccordinate system is not published The sign of the m_y element moments of the CWELD is wrong, it must be opposite to be the same as for the CBAR.

Description

In adition, the CWELD element force item codes are not published in the Quick Reference Guide and the rules for the element coordinate system have not been published. A word document is attached to this quality that contains all the necessary information for post processing the CWELD.

Known Error

CR 1-4100101

Known Error

CR 1-4100101

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Documentation/QRG - DIAG 49 - Remove DIAG 49 from QRG

Description

DIAG 49 should be removed for the Quick Reference Guide, see error 33293. The utility f04rprt should be used to summarize the f04 Execution Summary.

Known Error

CR 1-4117910

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Documentation/QRG - PARAM,XYUNIT - Missing Documentation The documentation for parameter XYUNIT is missing from the 2001 Quick Reference Guide. The documentation should read:

Description

XYUNIT n XYUNIT is used in conjunction with an FMS ASSIGN statement to specify the unit number for the storage of design sensitivity data in comma separated value format for use in a spreadsheet.

Known Error

CR 1-4126807

Product

MSC / MD Nastran

Corrected Version 2001.0.3 Abstract

Part Superelements - BEGIN SUPER, CORD - Possible Wrong Answers

Description

For a PART superelement, if the boundary point of a superelement uses a secondary displacement coordinate system, then the results may be incorrect. Avoidance: Use the assembly basic coordinate system at the boundary.

Known Error

CR 1-4150825

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Documentation/QRG - FREQ1 - Incorrect Formula The formula in Remark 3 of the FREQ1 bulk data entry description should say:

Description

(NDF+1) not

Known Error

CR 1-4150825 (NDF=1)

Known Error

CR 1-4168512

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Random - multiple subcases,freq - SWM 3002 In a random analysis, if there are multiple subcases, and each subcase has a different frequency callout, then the following unclear messages will be issued without performing a random analysis:

Description

*** SYSTEM WARNING MESSAGE 3002 (RANDOM) EOF ENCOUNTERED WHILE READING DATA BLOCK OUGV2 (FILE 104) IN SUBROUTINE RAND2 Avoidance: Use the same frequency callout for all the subcases

Known Error

CR 1-4168528

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Documentation/QRG - GPKE Not Available for Dynamic Response

Description

GPKE output is only supported for normal modes analysis. Contrary to what is indicated in Table 4-5 of the QRG, the GPKE output is not supported in SOL 108. GPKE output can be obtained for the normal modes part of the other modal dynamic solutions.

Known Error

CR 1-4195201

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Buckling - CWELD - Possible Wrong Answers

Description

The CWELD element does not support nonlinear analysis nor does it create a differential stiffness matrix. However, if the CWELD element is used in a SOL 105 buckling analysis, depending on the problem and machine that you are running on, the job may terminate without any message, yield incorrect results, or terminate with the following messages: MAIN: The FPU has been reset after floating point exception. MAIN: For reference, A(MAINAL) = 401380, A(/SYSTEM/) = 1915050 MAIN: A(/XNSTRN/) = 3320020

Known Error

CR 1-4195201 MAIN: "Floating point zero divide" (C000008E) exception encountered. MAIN: Exception occurred at address 010654CD. MAIN: Context Flags 0001003F MAIN: EAX 00000006 EBX 03

Known Error

CR 1-4214309

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Dynamic Analysis - Enforced Motion with Static Preload - Wrong Answers If enforced motion is used in a modal solution (SOL 111 or 112) with a static preload, the run will either fail indicating that no loading is defined or will run with incorrect results (if another loading is applied in addition to the enforced motion).

Description

Avoidance: Insert the following DMAP alter: compile SEMTRAN $ SOL 112 or SEMFREQ for SOL 111 alter 'umerge.*ys.*yg'(,-1) lcgen casers,slt,ett,dynamic,geom4s/cases2t/s,n,dummt/'tranresp' $ paraml cases2t//'dti'/1/4//s,n,load $

Known Error

CR 1-4239801

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Description

P-Elements - STRAIN, TEMP - Strain Output does not Include Thermal Strain The strain output for solid p-elements is the mechanical strain, which is the difference of the total and thermal strains. For a solid model undergoing free thermal expansion, the strain output would be zero, rather than the non-zero mechanical strain that is customary. The stress output is calculated from the mechanical strain and is correct.

Known Error

CR 1-4266901

Product

MSC / MD Nastran

Corrected Version 2004.0.4 Abstract

Distributed Memory Parallel - SPCD, DAREA - Wrong Answers for Frequency Response

Description

Sol 111 DMP returns incorrect responses for the responses for all slave processes when both SPCD and DAREA/LOAD type subcases are mixed

Known Error

CR 1-4266901 within same run.

Known Error

CR 1-4273414

Product

MSC / MD Nastran

Corrected Version Abstract

Optimization/Design Sensitivity - DVMRELi - SFM 4276 EC 3001 from DSAB0 In an optimization job, when an existing MATi entry is being designed by a DVMREL1/2 but has not been referenced by any property entry, then the job will fail in DSABO with SFM 4276, EC 3001.

Description Avoidance: Make sure the problematic MATi entry is referenced by a property entry. Known Error

CR 1-4299402

Product

MSC / MD Nastran

Corrected Version 2005.5 Abstract

Documentation/QRG - NLRGAP Contents Description Incorrect

Description

The MSC.Nastran Quick Reference Guide incorrectly describes the TABK field of the NLRGAP entry when it is set to less than zero. When TABK= 0, the element x-axis is set as in Remark 2..."

Description

This should be changed to specify Remark 3 instead of remark 2. I.E. Change the statement to "When CID >= 0, the element x-axis is set as in Remark 3..."

Known Error

CR 1-11725405 Also, the definitions on the TKIDi, TBIDi and TKNIDi fields on the PBUSHT can use some extra clarification. A statement should be added indicating that the data input corresponds to directions 1 through 6. For example, the TKIDi field is defined as follows: "Identification number of a TABLEDi entry that defines the stiffness vs. frequency relationship." This should be clarified to say: "Identification number of a TABLEDi entry that defines the stiffness vs. frequency relationship in directions 1 through 6."

Known Error

CR 1-11748419

Product

MSC / MD Nastran

Corrected Version Abstract

Nonlinear Output - NLPARM, INTOUT=NO, PARAM BUCKLE 2 - Extra Output

Description

When using PARAM BUCKLE 2, even though the NLPARM entry requests NO for INTOUT on the NLPARM entry, intermediate output will occur. The buckling mode plus all the intermediate increments are output. Only the first increment is not output.

Known Error

CR 1-11788602

Product

MSC / MD Nastran

Corrected Version 2004 Abstract Description

Case Control/XYPLOT - MPFORCE - Missing Output The MPCFORCE psdf output is not created when requested using the xyplot, xypeak, or xypunch option. Avoidance: Add the mpcforce=n case control command.

Known Error

CR 1-11794410

Product

MSC / MD Nastran

Corrected Version GL Abstract

Optimization/Design Sensitivity - PARAM EIGD with DVPREL and DVMREL UFM 6920 (MATMOD) IF PARAM,EIGD,YES is set and property plus material sensitivities are requested, the subdmap EIGVECDS will fail with the message:

Description

SYSTEM FATAL MESSAGE 6920 (MATMOD) The problem occurs because the DMAP logic in EIGVECDS has DVSG1 for DKPHI and DVSG1 for DMPHI, then the variables are wrong for MATMOD.

Known Error

CR 1-11794410 Avoidance: Use ONLY property OR material sensitivity in one run. Results for both cases can be combined externally Note: PARAM,EIGD has not been supported since V2004 when Eigenvector optimization was added to MSC.Nastran, therefore the existing issue will not be enhanced and this CR will be marked as a limitation.

Known Error

CR 1-11794426

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Description

Elements - QUAD4, TRIA3, FORCE(BILIN,CUBIC) - Wrong moment forces when SNORM=0. The FORCE(CUBIC) and FORCE(BILIN) data recovery options may produce incorrect moment forces for models when SNORM=0.. Avoidance: Use the SGAGE option.

Known Error

CR 1-11794442

Product

MSC / MD Nastran

Corrected Version 2004.0.3 Abstract

Description

Nonlinear Analysis - RFORCE - SFM 4276 EC 1305 In nonlinear analysis with follower forces, module EMAKFR fails to recognize that there can be more that one RFORCE entry referenced to a single grid point. If this condition exists the run will fail with SYSTEM FATAL MESSAGE 4276 ERROR CODE 1305 ENDPUT2. Avoidance: Adding param,followk,no avoids the fatal message but also turns off follower forces which will affect results. RFORCE entries must otherwise be combined so that there is only one entry per grid point.

Known Error

CR 1-11805508

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Transient Analysis - GPFORCE - SFM 6143 (UMRGE1) The message:

Description

SYSTEM FATAL MESSAGE 6143 (UMRGE1) incompatible size of ISS matrix is output in a SOL 109 Direct Transient with static preload when there is

Known Error

CR 1-11805508 a GPFORCE request ABOVE the subcase level and a change in SPC set size between subcases. Avoidance: Error may be avoided by putting the GPFORCE request in the static preload subcase ONLY.

Known Error

CR 1-11859503

Product

MSC / MD Nastran

Corrected Version Abstract

Distributed Memory Parallel - BSET, CSET - Poor Message, SFM 3007 (SEP1X) If bset and/or cset entries are used with GDMODES the the following fatal message that does not indicate the problem is issued:

Description

SYSTEM FATAL MESSAGE 3007 (sep1x) - illegal input to subroutine sepomt Avoidance: GDMODES does not support BSET, CSET or ASET entries.

Known Error

CR 1-11867901

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

DMAP - PARAML - Poor Diagnostics If the the value for the column index (p2) is set to a number larger than the number of columns in the input matrix the following system fatal exit takes place.

Description

SYSTEM FATAL MESSAGE 4276 (UNPACK) ERROR CODE 31 PID= 0 The .f04 file shows that the program ends with the statement "UNPACK TERM". It is not evident which module makes this .f04 entry. This makes it difficult to debug the user error.

Known Error

CR 1-11909101

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Description

Superelement Analysis - PARAM,FOLLOWK,YES - Wrong Answers Superelement analysis with follower forces (param,followk,yes) can lose follower stiffness if a follower grid specified load such as a force1 is associated with an external grid. This contribution is not currently computed in SEKDR if no physical structure is downstream.

Known Error

CR 1-11909101 Avoidance: Apply the following dmap alter: compile sekdr alter 'IF ( NOKDJJ=','' IF ( NOKDJJ=-1 ) THEN $ alter 'EMG ESTx'(,-1) if ( nogpect>0 ) then $ alter 'EMG ESTx'(,2) else $ equivx kfgg/kdjj/-1 $ endif $ nogpect>0 endalter

Known Error

CR 1-11917502

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Frequency Response - Freq. Dep CBUSH, Enforced Motion, SPCD - UFM 5423 (CFORCE2) In SOL 108, frequency response, if the model contains frequency dependent CBUSH elements and the excitation is direct enforced motion defined in the time domain using TLOAD entries and results are requested in the time domain using the TSTEP entry, SOL 108 usies the Fourier Transform Method but the data recovery will fail and the following fatal message will be issued from the CFORCE2 module:

Description

USER FATAL MESSAGE 5423 (SADD5) ATTEMPT TO ADD INCOMPATIBLE MATRICES, (SADD5) COLS ROWS FORM TYPE NZWD DENS TRAILER FOR QGX IS 501 12 2 2 2 833 TRAILER FOR QSGF IS 101 12 2 4 4 825 Avoidance: Insert the following DMAP alter in V2007/MDR2 or earlier: compile sedfreq alter 'IFT udF' IFT qsgf,CASES,TRL,FOL/ qsgft,TOLx/IFTM $ delete /qsgf,,,, $ DSAR qsgft,,,/qsgf,,,,/-1 $ and for V2008/MDR3: compile sedfreq

Known Error

CR 1-11917502 alter 'IFT PPF' IFT qsgf,CASES,TRL,FOL/ qsgft,TOLx/IFTM/false $ equivx qsgft/qsgf/-1 $ endalter

Known Error

CR 1-11943904

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Direct Frequency Response - iter=yes - Format Error in Table

Description

The iterative solver frequency summary table prints ***** for frequencies greater than 999. 999.

Known Error

CR 1-11974803

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Grid Point Force - GPFORCE, TEMP(LOAD) - Wrong Answers with many subcases SOL 101 may generate wrong translational results in the grid point force balance when more than 9 subcases exists with temp(load).

Description Avoidance: Duplicate the GPFO set and alternate in Case Control GPFO set assignments between duplicated set every nine subcases. Known Error

CR 1-11979905

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

External Superelements - EXTSEOUT - Missing Data Recovery Output

Description

An assembly superelement run employing an external SE created using the EXTSEOUT feature may fail to give data recovery output for the residual. See also quality 1-12962601.

Known Error

CR 1-11981265

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

Nonlinear Analysis - CTETRA(10) Yields Wrong Nonlinear Stress Output at grid points

Description

The nonlinear TETRA(10) element does not extrapolate the Gauss point stresses to the grid points correctly. In one analysis the nonlinear equivalent stress output for a plastic analysis with TETRA(10) elements exceeded the yield

Known Error

CR 1-11981265 stress value at grid points but the same analysis with HEXA(8) elements did not exceed the yield stress.

Known Error

CR 1-11989101

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Description

Optimization/Design Sensitivity - DLINK - Insufficient Memory The DOT optimizer may overestimate the memory allocation for an optimization job with the presence of DLINK entries due to a wrong variable reference. This bug will not affect any result accuracy. Avoidance: Request more memory.

Known Error

CR 1-12017009

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Differential Stiffness/Superelements, STATSUB - Wrong Answers If superelements are present in a buckling analysis, or a dynamic analysis with differential stiffness, and data recovery is not requested for all superelements then wrong answers will be computed. Avoidance: Make sure data recovery is requested for all superelements or insert the following alter: compile super3 alter 'dropt=3' if ( app='bkl0' ) cntl='all' $ endalter

Description

Bob Harder 10/25/05: I have studied the change made for Quality 112017009 and believe it is correct. The case I studied used a SEDR command for only the residual structure. Using Version 2001 with SEDR=[residual], no displacements were recovered for the upstream superelements, and hence no differential stiffness. Without the SEDR command, this Quality fix caused no change. This means that the SEDR=[residual] command used to eliminate the differential stiffness from upstream superelements, but it no longer does. If someone is doing a trick that requires no differential stiffness for upstream superelements, then he should use an ALTER.

Known Error

CR 1-12017009 COMPILE SEKDR $ ALTER 'NOKDJJ=-1','' $ IF (NOKDJJ=-1 AND SEID=0 ) THEN $

Known Error

CR 1-12018401

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Parallel Processing - DMP - Integer Overflow

Description

During wrapup of a DMP analysis, jobs may fail with an integer overflow. This may occur for large jobs that perform large amounts of message passing. It occurs while computing message passing statistics. It does not affect the results of the analysis.

Known Error

CR 1-12028801

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Optimization-missing response columns in DSCM2, optexit,4 An optimization task may fail with the illegal input error (SFM 3007 in DVGP42) when the following conditions are met:

Description

1. A shape optimization job with the rigid elements whose conneting grids being designed. 2. Some of shape variables are being lined with DLINK entries. Avodiance: remove dlink entries.

Known Error

CR 1-12029513

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Utilities - TRANS/RECEIVE - SIM T2 (CVTGET) If an xdb from a Windows V70.7 system is trans'd and received to a V2001 Unix system the following message may occur:

Description

*** SYSTEM INFORMATION MESSAGE T2 (CVTGET) ' ERROR IN TRANSLATING DATA. CHARACTER = ' SUPERS 1 0 0 0 0 0 00 **** SYSTEM INFORMATION MESSAGE T1 (CVTEND) 1 ERRORS OCCURED DURING TRANSMISSION PROCESS Avoidance: Use ascii ftp on the file before receiving

Known Error

CR 1-12029522

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Utilities - DDLADD, V70.7 xdb, Object CBAR DDL and Data Base

Description

ddladd may not work correctly for models with CBAR, CBEAM, CGAP, CBEND, and or CBUSH elements between Version 70.7 and 2001. See the MSC.Nastran 2004 Release Guide for the ddladd fix.

Known Error

CR 1-12055302

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Optimization/Design Sensitivity - Dynamic loads in Superelements - Wrong answers or UFM 3046 If dynamic loads are applied to the interior points of superelements without the use of the LOADSET Case Control command and LSEQ Bulk Data entries, then the loads will be ignored or UFM 3046 will be issued in SQFREQ or SFM 3001 in TRD2.

Description

Avoidance: Respecify dynamic loads with LOADSET and LSEQ or insert the following DMAP alter: compile presens alter 'lcgen ','' type parm,,char8,n,appx='reig' $ LCGEN CASES,SLTx,ETTx,dynamic0,geom4s/CASESX//appx $ endalter

Known Error

CR 1-12061001

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Buckling - EIGRL - Uses bad shift when first root is positive

Description

When f1 on the eigrl entry is blank, the Lanczos buckling solution computes a good estimate of the first root prior to the Lanczos solution. If the root is positive it discards it, and uses 1.0 as a first shift instead . Avoidance: Change the sign of the loads to obtain a negative first root.

Known Error

CR 1-12072604

Product

MSC / MD Nastran

Corrected Version 2004

Known Error

CR 1-12072604

Abstract

Eigenvalue Analysis - IRIX 64 - Signal 10 Bus Error The IRIX64 patch to correct Lanczos error 1-5821710, available for downloaded from: www.mscsoftware.com/support/software_updates Requires that setenv FORMAT_TYPE_CHECKING RELAXED

Description

be set in nast2001t2.lcl or the .cshrc file else Receiving signal number 10: Bus error Job aborting... will be encountered. The system may also require new libftn.so, libfortran.so, and libffio depending on the o/s. level.

Known Error

CR 1-12083006

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Optimization/Design Sensitivity - UFM 1126 The following USER FATAL MESSAGE can occur in a job with fully stressed design (FSDMAX>0) and the P2=16 print option is active. USER FATAL MESSAGE 1126 (GNFIST) DMAP MODULE WEIGHT IS ATTEMPTING TO OUTPUT DATABLOCK WMID WHICH ALREADY EXIST

Description Avoidance: Include the following DMAP alter compile desopt alter 'casdsn,casadj','casdsn,casadj' dbdelete datablk=(r1val,r1tabr,r1valr,drstbl, RQATABR, casdsn,casadj,wmid) , where(solapp=* and seid=*) $

Known Error

CR 1-12104806

Product

MSC / MD Nastran

Known Error

CR 1-12104806

Corrected Version 2004 Abstract

Acoustic Analysis - PARAM,MECHFIX,YES - Poor Performance Specifying PARAM,MECHFIX,YES in conjunction with acoustics (fluidstructure interaction) results in SWM 3081. Results are unaffected but performance may be slightly degraded. Avoidance: Insert the following alter:

Description

compile xread alter 'Equivx  mxx\/mxx2' equivx vaxf/vspc/-1 $ alter 'partn mxx,vspc,\/mxx2' dbstatus vaxf//s,n,novaxf $ if ( novaxf>0 ) then $  partn vaxf,,vspc/vx,,,/1 $  equivx vx/vspc/-1 $ endif $ endalter

Known Error

CR 1-12122861

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Documentation/QRG - CBUSH - UFM 6629 (TA1BSH) The following remark should be added to the QRG description of the CBUSH entry:

Description If the distance betwen GA and GB is less than .0001, or if GB is blank, then CD must be specified. Known Error

CR 1-12122896

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Description

Grid Point Force - GPFORCE, CELAS2 - Wrong Answers In Version 2001 wrong answers for grid point force output may occur when a CELAS2 element connects components of the same grid. A symptom of the error is repeasted a repeated element ID in the GPFORCE output. An example of a CELAS2 entry that causes this error is: celas2,123,55.0,101,1,101,5 Avoidance: There is no avoidance. Version 70.7 gives correct answers.

Known Error

CR 1-12142116

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Description

Utilities - DDLADD, SFM 1001 (BLKRD), SFM 6059 In rare cases the ddladd utility may fail with the message: *** SYSTEM FATAL MESSAGE 1001 (BLKRD) ERROR ENCOUNTERED READING BLOCK 758197808, ERROR CODE = 6007. DATA BASE NUMBER = 1, UNIT = 40, MESSAGE IS -Read block number beyond End-of-file. 0*** SYSTEM FATAL MESSAGE 6059 (DIOMSG) NO ERROR MESSAGE EXISTS FOR DIOMSG INTERNAL CODE NUMBER 999 CALLED FROM BLKRD FATAL ERROR DETECTED Avoidance: There is no avoidance other than to recreate the database.

Known Error

CR 1-12168411

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Case Control - SDAMP, K2PP, M2PP, B2PP - Unexpected Answers, Missing UFM 9041 for SOLs 118, 146, 200 Beginning in Version 2004 changes to TF, K2PP, M2PP, B2PP and SDAMPING between subcases in SOL 107 through 112 are supported and UFM 9041 is no longer issued. However, these changes are still not supported in SOLs 118, 146 and 200 and beginning in Version 2004 they are ignored and unexpected answers result. The following fatal message should still be issued:

Description ^^^ USER FATAL MESSAGE 9041 (PHASE0) ^^^ THERE ARE CHANGES IN K2PP, M2PP, B2PP, SDAMP, OR TFL. ^^^ USER ACTION: SPECIFY K2PP, M2PP, B2PP, SDAMP, AND TFL ABOVE ALL SUBCASES. Avoidance: Other than not making these changes between subcases, there is no avoidance. Known Error

CR 1-12205901

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Elements - CTETRA, TEMP(LOAD) - Wrong Answers on Itanium HPUX

Description

Models with tetra elements, thermal loads, and local coordinate systems may yield wrong results on the in Version 2001 on Itanium HPUX computers.

Known Error

CR 1-12222802

Product

MSC / MD Nastran

Corrected Version 2004 Abstract Description

File Management Section - DBVIEW Using the DBVIEW statement to output a datablock does not work correctly if the WHERE clause is omitted. Avoidance: Add the WHERE clause to the DBVIEW statement.

Known Error

CR 1-12255710

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Dynamics - SPCD/RESVEC - 111 to 103 restart - UWM 2071 (dpd2)

Description

A sol 111 restart to a sol 103 run will fail with ufm 5423 (mpyad) when more than one base motions are specified using more than one RLOADi cards and when residual vectors are requested. However the ufm is only part of the problem. Just before the ufm uwm 2071 (dpd2) shows up indicating that the RLOADis after the first one will be ignored. Avoidance: Use the large mass approach This CR is related to 1-18217901. Please refer to the avoidance schemes given under the description of that CR.

Known Error

CR 1-12263602

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract Description

Buckling Analysis - EIGRL, Lanczos - Missing Eigenvalues In a buckling analysis, if more than one root is requested with the ND field and both F1 and F2 are blanks, the higher roots may not be found Avoidance: Specify a higher ND value than desired or put in the F2 value.

Known Error

CR 1-12265515

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Matrix Methods - DECOMP - Insufficient Memory, Receiving signal number 11: Segmentation fault

Description

Large models with insufficient memory may fail in decomp with the only message being issued to the log file:

Known Error

CR 1-12265515 Receiving signal number 11: Segmentation fault Avoidance: Request more memory

Known Error

CR 1-12277506

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Description

Frequency Response - FREQ, FREQ1, FREQ2 - Missing Output In frequency response analysis if a FREQ entry exists that explicitly defines more than 9999 frequencies or there is a combination of FREQ1 and FREQ2 entries that define more than 9999 frequencies, than not all frequencies will be solved for. If 12000 frequencies are defined, then only the first 2000 frequencies will be solved. Avoidance: Either define the frequency steps with only a freq1 or only a freq2 entry, else break the frequency steps up and solve in separate runs.

Known Error

CR 1-12301602

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Groundcheck - CBEND - Fails Groundcheck

Description

The CBEND element fails the Ground check.

Known Error

CR 1-12310701

Product

MSC / MD Nastran

Corrected Version GL Abstract

Optimization/Design Sensitivity - Superelements, DCONSTR - Missing Fatal Message If a DCONSTR points to a response that does not exist, it is typically a User Fatal Error. However, if the the design task includes superelements, the user input error is not detected and the DCONSTR that points to the nonexistent response is simply ignored.

Description Avoidance: There is no avoidance except to carefully check that the referenced responses exist or to remove the superelements from the job for purposes of checking the user input. Known Error

CR 1-12315301

Product

MSC / MD Nastran

Corrected Version 2004

Known Error

CR 1-12315301

Abstract

Nonlinear Analysis - TEMP(BOTH) - Plane strain analysis yields incorrect out of plane rotations

Description

A nonlinear plane strain analysis using CQUAD4 elements, with thermal loads and temperature dependent material properties results in out-of-plane rotations being calculated when they should be all zero.

Known Error

CR 1-12356001

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

DMAP - INPUTT2 - SFM

Description

The INPUTT2 module will fatal if an attempt is made to rewind ITAPE=-3 on an unlabeled op2 file.

Known Error

CR 1-12388901

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Superelements - enforced motion, external superelements - Wrong answers If a boundary point of an external SE created using the EXTSEOUT feature has enforced motion specified for it in a subsequent assembly run, then its results come out OK as part of the residual output in the assembly run, but come out as null values as part of the external SE output. Avoidance: Specify PARAM,SPARSEDR,NO or insert the following DMAP alter:

Description

compile spdr1 alter 'call xAdd5 vscg0,vmcg,vadr,z01dr0,vyg' add5 v01z,vupse,,,/zzz $ equivx zzz/v01z/-1 $ compile super3 alter 'MPYAD ULS,UH2,\/ULS1','' MPYAD ULS,UH2,yls0/ULS1 $ endalter

Known Error

CR 1-12460901

Product

MSC / MD Nastran

Corrected Version Abstract

Aeroelastic Analysis - Poor Trim specification leads to misleading error

Description

If a user create a trim case that has more supported degrees of freedom

Known Error

CR 1-12460901 than controllers (URDDs, to be specific), the following error may be generated: SYSTEM FATAL MESSAGE 3008 (UTMCOR) MODULE = ASG INSUFFICIENT CORE AVAILABLE FOR SUBROUTINE ZZXHMD USER ACTION: INCREASE OPEN CORE BY AT LEAST 7 WORDS PROGRAMMER INFORMATION: LOCATION KEY = PI1 0FATAL ERROR This message does not indicate the real problem, so it is of no use to the user. The fix is to put in an error check to test that the number of supported degrees of freedom equals the number of URDD controllers. This check should be located at the begining of ASGD.

Known Error

CR 1-12484501

Product

MSC / MD Nastran

Corrected Version 2004 Abstract Description

DMAP - MATMOD option 12 - Wrong answers MATMOD option 12 with P41 on the FREQ3 entry also avoids the error.

Known Error

CR 1-13711524

Product

MSC / MD Nastran

Corrected Version 2004.0.3 Abstract

Description

Miscellaneous - INCLUDE - .blk files not included. In version V2004 the new output file named "filename.blk" is created for every run which contains sorted bulk data for SOL 200. Thus, the nastran command script renames the existing "filename.blk" to filname.blk.1" during the run. IF the NASTRAN command line option OLD=NO is set "filename.blk" will be deleted. To overcome this problem rename "filename.blk" to "filename.xxx", where "xxx" is anything other than "blk". Avoidance: Avoid using "blk" as a include file name extension.

Known Error

CR 1-13713263

Product

MSC / MD Nastran

Corrected Version 2004.0.3 Abstract

Postprocessing/DMAP - PARAM,POST - Incorrect GEOM2X and GEOM3X Output2 data.

Known Error

CR 1-13713263 In MSC.Nastran 2004.0.0 the data written in the OUTPUT2 GEOM2X and GEOM3X data blocks is incorrect. Avoidance: Apply the following dmap alter.

Description

compile out2geom alter 'output2 geom2x','' OUTPUT2 GEOM2x,GEOM3x,GEOM4x,geom1x,bgpdtx//0/OUNIT1//OMAXR/ GEOM2 / GEOM3 / geom4 / geom1 / bgpdt / 'geom2'/'geom3'/'geom4'/'geom1'/'bgpdt' $ endalter

Known Error

CR 1-13715501

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Component Mode Synthesis - CSET - Wrong Answers

Description

A small CMS job using CSET reduction gives erroneous results if all of the component modes are employed. However, the same job gives good results if PARAM,MHRED,NO is specified or if only a subset of the total component modes are employed In Version 2005 this condition is trapped with a message that instructs the user how to avoid the problem.

Known Error

CR 1-13732901

Product

MSC / MD Nastran

Corrected Version 2004.0.5 Abstract

Component Mode Synthesis - CSET, QSET - Wrong Answers

Description

Component Mode Synthesis should give exact results if all eigenvalues are included. A small CMS job employing a part SE and CSET reduction and with Q-set data defined in the part SE Bulk Data gives erroneous results if all of the component modes are calculated. Furthermore, different erroneous results are calculated if the Q-set data in the part SE Bulk Data are replaced by an equivalent SENQSET entry in the Main Bulk Data.

Known Error

CR 1-13760301

Product

MSC / MD Nastran

Corrected Version 2004.0.3 Abstract

SOL 600/Implicit Nonlinear - Extra Datablocks in op2 file

Description

SOL 600 is writng extra datablocks to the op2 file for the initial Nastran 2004 release. Programs such as Medina and Animator may have trouble handling

Known Error

CR 1-13760301 these extra geometry datablocks. Avoidance: This can be avoided by the user employing his own DMAP to control the datablocks written to the op2 file rather than specifying outr=op2 on the SOL 600 entry.

Known Error

CR 1-13760501

Product

MSC / MD Nastran

Corrected Version GL Abstract

Rotor dynamics jobs can go unstable in transient integration Some of the terms used in rotordynamixs are nonlinear (equivalent to NOLINs) and may cause the linear transient integration scheme to go unstable. The manual states that the integration routine is unconditionally stable, but that is only for linear, stable problems.

Description Avoidance: If an instabilty occurs in linear transient rotordynamics, try reducint the integration timestep. If that fails, check the rotordynamics forces to verify that they are not growing unconditionally. Known Error

CR 1-13762804

Product

MSC / MD Nastran

Corrected Version

2004.0.4

Abstract

Installation - Sun Solris64 installation is missing shared object libraries. The MSC.Nastran V2004 installation for Sun Solaris 64 systems is missing shared object libraries. The libraries are needed if the system does not have Fortran compilers installed. These libraries may be downloaded from the MSC.Software web site:

Description

http://www.mscsoftware.com/support/software_updates/index.cfm#nastran and at: http://www.engineering-e.com/download/?productid=15

Known Error

CR 1-13767914

Product

MSC / MD Nastran

Corrected Version 2004.0.3

Known Error

CR 1-13767914

Abstract

Optimization/Design Sensitivity - PARAM,DESPCH1,-1 option fails for PBEAM entries

Description

When a negative number is specifified for PARAM,DESPCH1 to indicate that small field format is to be used and the analysis model contains PBEAM entries, the job will fial with an error message in the log file. Avoidance: Use a positive number, i.e. large field format.

Known Error

CR 1-13776201

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Documentation/QRG - RESVEC Keyword DMPLOD, NODMP Lead to UFM 601, Should be DAMPLOD and NODAMP

Description

The documented keywords for the RESVEC Case Control Command DMPLOD and NODMP do not work. The correct spelling is DAMPLOD and NODAMP. The incorrect spelling leads to UFM 601 (IFP1D) THE KEYWORD ON THE ABOVE CARD TYPE IS ILLEGAL OR MISSPELLED.

Known Error

CR 1-13794801

Product

MSC / MD Nastran

Corrected Version 2004.0.3 Abstract

Rigid Elements - PARAM,AUTOMSET - SFM 4276 EC 5 in UFBS If the dependent node of an RBE is restrained and PARAM,AUTOMSET,YES is specified, the analysis may fail with the message: *** SYSTEM FATAL MESSAGE 4276 (UFBS2) ERROR CODE 5 PID= 0 *** USER INFORMATION MESSAGE 4276 (UFBS2) Avoidance: Apply the following dmap avoidance:

Description

DMAP avoidance is: compile autom alter 'TRNSP RMAL','' $ TRNSP RMAL/RMALTx $ matmod RMALTx,,,,,/Rjunk,RMALTnz/12/s,n,NLnull/1 $ if (NLnull > 0) then $ add rmaltx,RMALTnz/rmalt $ else $ equivx rmaltx/rmalt/-1 $ endif $

Known Error

CR 1-13794801 endalter $

Known Error

CR 1-13802801

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Documentation - Release Guide - Minor Corrections The following modifications should be made to the MSC.Nastran 2004 Release Guide. Release guides are not re-issued so this error report is being marked as addressed in V2005. On page 530, Table 13-1, the descriptor "SRESS" should be modified to "STRESS" On page 533, the first K2PP should be modified to K2GG On page 533, the first M2PP should be modified to M2GG On page 349, the 3rd sentence in the second paragraph should read "Solutions specified in table 3-3 of the standard SOL statement may be used." On page 352, "MSC.Marcs" should be changed to "MSC.Marc" On page 374, 'inlstrs5.DBALL' and 'inlstrs5.MASTER' should be modified to

Description

'nlstrs5.DBALL' and 'nlstrs5.MASTER', respectively. On page 353, MATT should be modified to MATF On page 354, MATV should be modified to MATVE On page 355, MARCSHLT and MARSUMY should be modified to MARCSLHT and MARCSUMY, respectively. On page 611, the description for word 8 of the CWELD should be "Coordinate system for the type of projection" On page 594, the description for OSTR should be changed from stresses to strains. On page 572, the second sentence of the second paragragh should read " To indicate conversion

Known Error

CR 1-13802801 to "OLD" entry structure, the character "O" is placed as the last character of the Special Version field.

Known Error

CR 1-13817704

Product

MSC / MD Nastran

Corrected Version 2004.0.3 Abstract

ACMS - ASET1 - ACMS ignores ASET1 data beyond the first entry

Description

In ACMS analysis grid points on ASET and ASET1 entries are moved into the residual structure. However if there is more than one ASET1 entry in the bulk data, the ASET1 data beyond the first entry is ignored.

Known Error

CR 1-13830101

Product

MSC / MD Nastran

Corrected Version 2004.0.3 Abstract

Description

Miscellaneous - PARAM,CHECKOUT,YES - SFM 3001 (MTRXIN) Jobs using the PARAM,CHECKOUT,YES feature could fail with SFM 3001 from the MTRXIN module if there is a K2GG case control command selecting a stiffness matrix and there is no M2GG command selecting a mass matrix. Avoidance; The error can be avoiding the MTRXIN in with a dmap alter.

Known Error

CR 1-13860606

Product

MSC / MD Nastran

Corrected Version 2004.0.3 Abstract

Superelements - MPCF, SPCF - Wrong Answers with Sparse Data Recovery In V2004, the new sparse data recovery can cause errors in the displacement vector for superelements when displacements are requested for only some of the GRID points in the model at the same time as MPCF or SPCF requests are made. This error occurs only in the direct solution sequences; i.e., 101, 103, 108, 109, and 200 with ANALYSIS=DFREQ.

Description

Resolution: Either use PARAM,SPARSEDR,NO to deactivate sparse data recovery methods or insert the following alter: COMPILE SPDR1 NOLIST $ ALTER 189 $ DIAGONAL V01S/V01SX/'WHOLE'/0. $ EQUIVX V01SX/V01S/-1 $

Known Error

CR 1-13860606 ENDALTER $

Known Error

CR 1-13860635

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Description

Superelements - MPCF - Wrong Answers with Sparse Data Recovery In V2004, in a superelement, if MPCF output is requested for only some of the GRID points of the model, the MPCF output may be in error if sparse data recovery is active, i.e. PARAM,SPARSEDR,YES (default). In addition, an SPCF output request will be ignored. This error occurs only in the direct solution sequences; i.e., 101, 103, 108, 109, and 200 with ANALYSIS=DFREQ. Avodaince: Use PARAM,SPARSEDR,NO

Known Error

CR 1-13875001

Product

MSC / MD Nastran

Corrected Version 2004.0.6 Abstract

Miscellaneous - INPUTT4 - UWM 6445 (INPTT4) A formatted INPUTT4 read for more than one matrix will fail with the following Fortran READ error: UWM 6445 (INPTT4):

Description

A FORTRAN FORMATTED READ ERROR HAS OCCURRED WHILE PROCESSING UNIT = ... USER INFORMATION: THE FILE WAS SPECIFIED IN AN ASSIGN FILE MANAGEMENT STATEMENT USER ACTION: VERIFY THE FILE ASSIGNMENT AND AND CONTENTS OR CONTACT MSC.SOFTWARE. VERIFY DATA AND FORTRAN SPECIFICATION. PROGRAMMER INFORMATION: FORTRAN IOSTAT CODE = ...

Known Error

CR 1-13876601

Product

MSC / MD Nastran

Corrected Version 2004.0.3 Abstract

Impicit Nonlinear (SOL 600) - MATF Can Only Process One Failure Criteria The SOL 600 MATF entry can only handle one failure criteria instead of three.

Description Avoidance: Enter MATF entry three times.

Known Error

CR 1-13894501

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Postprocess - DBC, PARAM,FIXEDB - Unable to Open Input Relations PARAM,FIXEDB in SOLs other than 101 and 103 forces an incorrect approach code into the DBC module causing the following error:

Description

" UNABLE TO OPEN INPUT RELATION TOL RETURN CODE = 1." Avoidance: Remove PARAM.FIXEDB from the input file.

Known Error

CR 1-13897501

Product

MSC / MD Nastran

Corrected Version 2004.0.3 Abstract

Implicit Nonlinear (SOL 600) - MATF - Unnecessary Input All continueation entries and all failure criteria constants are required for the MATF entry even though only the frist constant is needed for the most simple max stress criteria.

Description

This needs to be changed so that only those constants required to satisfy the failure criteria chosen need be entered. Thus, for the max stress criteria, only the first entry is required and only the first constant needs to be defined.

Known Error

CR 1-13915501

Product

MSC / MD Nastran

Corrected Version 2004.0.3 Abstract

Description

Optimization/Design Sensitivity - PBEAML - Wrong Answers In MSC.Nastran Version 2004 an optimization job will produce incorrect dimentions for an intermediate station or at end B of the PBEAML entry if the following conditions are met: 1. PBEAML entry is used that has SO=NO on other stations, 2. Only end A is designed.

Known Error

CR 1-13915504

Product

MSC / MD Nastran

Corrected Version 2004.0.3 Abstract

Optimization/Design Sensitivity - DESPCH, DESPCH1 - UFM 315 (IFPDRV)

Description

When an optimization job designs any real value on a CBEAM, CQUAD4 and/or CTRIA3 entry, bad punch output for these entries may be produced leading to UFM315 (IFPDRV) when they are included in a cold restart job.

Known Error

CR 1-13915504 The same job may also fail with traceback of Segmentation Violation on AIX machine. Avoidance: No practical avoidance exists except to manually modifiy the offending entries. Keywords: DESPCH DESPCH1

Known Error

CR 1-13928902

Product

MSC / MD Nastran

Corrected Version 2004.0.3 Abstract

Dynamic Response - MCFRACTION, MEFMASS - SFM 4276 (UNPACK) EC31 Modal dynamic response analysis that have multiple subcases that reference the same FREQ set but different DLOAD sets and request modal participation factor output may fail with the following message:

Description

*** SYSTEM FATAL MESSAGE 4276 (UNPACK) ERROR CODE 31 PID= 0 Avoidance: A possible avoidance is to define and reference a duplicate set of FREQ data for the second and subsequent subcases.

Known Error

CR 1-13930009

Product

MSC / MD Nastran

Corrected Version 2004.0.4 Abstract

Documentation/QRG - SOL400, RIGID=LGELIM - UFM 7615 (MDG2RG) The case control command RIGID=LGELIM as described in the MSC.Nastran V2004 Quick Reference Guide produces the following error because the option should be LNELIM.

Description

*** USER FATAL MESSAGE 7615 (MDG2RG) FOR NONLINEAR SOLUTION SEQUENCE, THE CASE CONTORL COMMAND 'RIGID=LGELIM' IS ILLEGAL. USER INFORMATION: THE LEGAL VALUE IS 'LNELIM' OR 'LAGR'. *******ALSO the word CONTROL is spelled wrong.****** For SOL400, the RIGID=LGEL method is not available, therefore a fatal error is issued. The wording 'USER INFORMATION: the legal value is 'LNELIM' or

Known Error

CR 1-13930009 LAGR' is corrected to 'USER INFORMATION: the legal value is LINEAR or LAGR'. Also the word CONTROL is corrected.

Known Error

CR 1-13948931

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

Dynamics/Enforced Motion - SPCD - Excessive disk space and CPU In V2004, enforced motion in dynamics may use excessive disk space and CPU.

Description Avoidance: Insert the DMAP alter in the attachment.

Known Error

CR 1-13987701

Product

MSC / MD Nastran

Corrected Version 2004.0.3 Abstract

Spotweld - CWSEAM - UFM 7549, Cannot find projection points for CWSEAM elements

Description

The default pcid of CWSEAM elements was not set appropriately. This error results in USER FATAL MESSAGE 7549 indicating that it cannot find projection points for the CWSEAM elements that are projected along the x-axis.

Known Error

CR 1-13989006

Product

MSC / MD Nastran

Corrected Version 2004.0.2 Abstract

Miscellaneous - XNASTRAN - Error while loading shared libraries

Description

The XNASTRAN interface may fail on some Linux operating systems with the message: "error while loading shared libraries: lib*: cannot open shared object file: No such file or directory." Avoidance: Use the nastran command.

Known Error

CR 1-13998601

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Documentation/QRG - FMETHOD Case Control Command Description Missing

Known Error

CR 1-13998601

Description

The FMETHOD Case Control command was inadvertently deleted from the V2004 Quick Reference Guide. Also remark 1 under the FLUTTER bulkdata entry description should point to the FMETHOD command not the METHOD command

Known Error

CR 1-13998604

Product

MSC / MD Nastran

Corrected Version 2005.5 Abstract

Documentation/Aeroelastic Analysis/QRG - Missing Parameter Description The description of parameter supaero is missing from the Version 2004 Quick Reference Guide. It should read:

Description

SUPAERO Default=ZONA If SUPAERO = ZONA, then the ZONA51 code is used for supersonic aerodynamic calculations. If SUPAERO = CPM, then the CPM method is used. If ZONA51 is not available at a particular installation, PARAM, SUPAERO,CPM must be specified to avoid a fatal error when performing supersonic aerodynamic analyses. Only one supersonic aerodynamics method can be selected in a given run. This parameter is available in solution sequences 144,145,146 and 200 and can be specified in either case control or as a bulk data entry.

Known Error

CR 1-13998611

Product

MSC / MD Nastran

Corrected Version 2005.5 Abstract

Documentation/COG/DMP - ssh/scp not supported

Description

The nastran init scripts currently have rsh and rcp hardcoded and will not work in an environment that uses ssh. This will prevent distributed memory parallel jobs from working in a network that only supports ssh and will also prevent execution of any job on a remote node. If a client wants to use ssh and scp, they either need to: 1. Change all the rsh/rcp to ssh/scp 2. make links between ssh/scp and rsh/rcp

Known Error

CR 1-13998622

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Documentation/QRG - ROTORG, TSTEPNL, Rotordynamics - Traceback in TRD1

Known Error

CR 1-13998622

Description

The new rotordynamics capability in MSC.Nastran 2004 includes nonlinear effects which make the transient response algorithm not unconditionally stable. As such rotordynamics analysis may fail with a traceback in trd1. If this happens the user should specify a smaller timestep.

Known Error

CR 1-14045201

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Optimization/Design Sensitivity - Poor Performance when DRESP applies to more DOFs than DESVAR. The perofrmance gain may be affected negatively for an optimization job with design responses that cover more dofs of the structure than design variables. Avoidance: Use the following dmap alter. Notice that the following alter applies to the case of static/normal mode and buckling. It can be reapplied to a different solution type by modifying the alter statement.

Description

compile pslgdv alter 'outprt'(1),'' if (spdm) outprt caseds,ects,bgpdts,sils,,,,,,, tabevp0,tabevs0,,,/ vgdr,,,,/s,n,sdr/0/'auto'/spdmrat $ compile respsen alter 'outprt'(1),'' if (spdm) outprt caseds,ects,bgpdts,sils,,,,,,, tabevp0,tabevs0,,,/ vgdr,,,,/s,n,sdr/0/'auto'/spdmrat $

Known Error

CR 1-14051758

Product

MSC / MD Nastran

Corrected Version GL Abstract

Licensing - FlexLM uncounted nodelock codes on SGI Altix / Linux Itanium 2 It has been reported in MSC.Nastran 2004 on SGI Altix Linux Itanium 2 computers that uncounted nodelock FlexLM licenses do not work.

Description

The nastran log file shows that the MSCID is different than lmhostid on a SGI Altix computer (Linux - Itanium 2). Avoidance: Use the MSCID reported by Nastran when generating the license.

Known Error

CR 1-14061906

Known Error

CR 1-14061906

Product

MSC / MD Nastran

Corrected Version Abstract

Restarts - sparse data recovery - Wrong Answers In a dynamic data recovery restarts, if only additional output is requested at more points and/or elements then results related to the additional grids and/or elements will be null, missing, or wrong.

Description

Avoidance: Insert the following DMAP alter: compile disprs alter 'equivx upx\/upf'(,-1) delete /upf,,,, $ endalter

Known Error

CR 1-14063502

Product

MSC / MD Nastran

Corrected Version 2004.0.4 Abstract

SOL 600/Implicit Nonlinear - Hyperelastic Element with midside nodes not Properly Mapped to Marc.

Description

The hyperelastic CHEXA element with mid-side nodes is not properly mapped to the corresponding Marc element, instead it is mapped to the corresponding 8-node Marc hyperelasic hexa element. The net result is that deformed plots show the mid-side nodes standing still and strange plots results.

Known Error

CR 1-14068501

Product

MSC / MD Nastran

Corrected Version GL Abstract

DMP - Linux - LAM won't boot with BAT=YES Starting w/ 2001R4 (2001.0.9) MSC.Nastran boots the LAM/MPI daemons for the user. However, with RH7.3 and Slackware systems, the LAM daemons may not boot if "BAT=YES" is specified.

Description

Avoidance: Use BAT=NO This problem does not occur w/ MSC.Linux. The problem is because when BAT=YES is used, the first process completes, and the child processes become ZOMBIES. We set a flg to ignore child zombies. Because of that flag, LAM daemons

Known Error

CR 1-14068501 will not start from within the shell. I think starting the lam daemons for the users is more important then BAT=YES, so I am leaving the code as is.

Known Error

CR 1-14077901

Product

MSC / MD Nastran

Corrected Version 2010.1.3 Abstract

Description

Optimization/Design Sensitivity - Eigenvector Sensitivities Require PARAM SPARSEDR=no Sparse data recovery in SOL 200 and eigenvector sensitivity analysis were both introduced in the 2004 release. It has been found that these two capabilities are not fully compatible. Avoidance: When eigenvector sensitivities are required, set PARAM SPARSEDR NO

Known Error

CR 1-14116602

Product

MSC / MD Nastran

Corrected Version 2004.0.5 Abstract

Dynamic Analysis - EPOINTS, M2PP, B2PP, K2PP, SPCD - UFM 1126 for K2GG EPOINTS and enforced motion with K2PP, B2PP or M2PP input may cause USER FATAL MESSAGE 1126 to be encountered.

Description

Avoidance: Insert the following DMAP alter: compile gma alter 'k2gg'(2,-1) delete /k2gg,,,, $ endalter

Known Error

CR 1-14120001

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Description

Frequency Response - freq-dep elements, MPCForces - SFM 6143 SFM 6143 has been observed when performing a frequency response analysis in SOLs 108, 111, 146, and 200 with frequency dependent elements and MPCForces are being requested

Known Error

CR 1-14120001 User Avoidance: Specify PARAM SPARSEDR NO or insert the following DMAP alter: compile fdrmgen alter 'equivx rxmgx\/rxmg','' alter 'paraml rmgg' if ( spdrm ) then $ equivx rxmgx/rxmg/-1 $ delete /rgm,,,, $ trnsp rxmg/rgm $ endif $ endalter

Known Error

CR 1-14120004

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Aeroelasticity - SOL 146, PBUSHT - UFM 2170 The presense of PBUSHT entries in SOL 146 may cause UFM 2170 to be issued. Avoidance: Insert the following DMAP alter.

Description

compile seaero alter 'call freqrs','' CALL freqrs CASES ,USETD ,DLT ,FRL ,trl , rph ,DIT ,EST ,cstms ,mpts , bgpdts ,gpsnts ,GPECT ,SILS ,edts , khh ,mhh ,bhh , ,qhjl , acpt ,cstma ,qhhl , ,ditid , ,rghfd ,rsgg ,rmgg ,PpF , fol , ,vgfd , ,pyhf , , , , ,ypf1 / aUhF ,qmgf ,qsgf ,phf / soltyp /freqdep /noa /fourier /false / 1 /true /bov /dompcffd/dospcffd/ false /noue /0 $ endalter

Known Error

CR 1-14125525

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Inertia Relief - PARAM,INREL, SUPORT - Multiple load case and DIMG,UACCEL, SFM 6144

Description

Multiple boundary conditions with DMIG,UACCEL in SOL 101 will terminate

Known Error

CR 1-14125525 with SYSTEM FATAL MESSAGE 6144. Avoidance: Insert the following DMAP alter: compile statrs alter 'urax' type db pg $ PARAML pg//'TRAILER'/1/S,N,NCUL $ total no. of loads if ( (ncul-6)nloads ) then $ ncul=ncul-6 $ nskip=nskip-1 $ MATGEN ,/COL/6/NCUL/NSKIP/NLOADS $ PARTN urax,COL,/,,urax1,/1 $ loads equivx urax1/urax/-1 $ endif $ endalter

Known Error

CR 1-14139801

Product

MSC / MD Nastran

Corrected Version 2004.0.4 Abstract

Acoustic Analysis/Enforced Motion - SPCD - SFM 6144 (PARTN1) In direct frequency response, sol 108, the new relative enforced motion capability in MSC.Nastran Version 2004 will encounter a matrix incompatibility fatal message when fluid is added to structure.

Description

*** USER WARNING MESSAGE 2125 (VEC) MODULE VEC - NZ=0, ONE OR MORE COLUMNS OF OUTPUT MATRIX WILL BE NULL. *** SYSTEM FATAL MESSAGE 6144 (PARTN1) THE SIZES OF THE INPUT MATRICES AND PARTITIONING VECTORS ARE INCOMPATIBLE. SPECIFICALLY: The number of rows in KAA is not equal to the number of rows in the row partitioning vector VAY The number of columns in KAA is not equal to the number of rows in the column partitioning vector VAY

Known Error

CR 1-14144521

Product

MSC / MD Nastran

Corrected Version 2006 Abstract

Superelements - BNDFIX1 - Unexpected ASET when QSET omitted

Known Error Description

CR 1-14144521 If BNDFIX1 degrees of freedom are specified, but no QSET is specified, then the BNDFIX1 entry is ignored. Avoidance: Use the ASET entry.

Known Error

CR 1-14155701

Product

MSC / MD Nastran

Corrected Version

2004.0.5

Abstract

Distributed Memory Parallel - DMP - Does not work on Primepower

Description

The 32 bit nastran driver program delivered with MSC.Nastran 2004.0.0 under the Solaris achitecture will not work for Distributed Memory Parallel (DMP) on Primepower systems. Avoidance: Download a new driver program from: http://www.mscsoftware.com/support/software_updates/index.cfm#nastran

Known Error

CR 1-14176601

Product

MSC / MD Nastran

Corrected Version 2004.0.3 Abstract

Description

Dynamic Analysis - MCFRACTION, SET - Missing Output If the MCFRAC case control command selects a SET that contains an implied thru range, only the first degree of freedom in each of the ranges will be output. The implied thru range is a continous range of degrees of freedom for a grid point as in 969/T1,969/T2,969/T3. Avoidance: An avoidance is to select grid/dof combinations that do not imply thru and use restarts changing the MCFRACTION SET content to recover all of the required data.

Known Error

CR 1-14180601

Product

MSC / MD Nastran

Corrected Version 2004.0.4 Abstract

SOL 600 - CQUAD4, CTRIA3 - Variable thicknesses on continuation entry not translated correctly.

Description

For SOL 600, thickness specified by continuation lines on CQUAD4 and CTRIA3 entries are not properly translated. There is also a priority conflict between these thicknesses and those specified by the NTHICK option.

Known Error

CR 1-14186901

Product

MSC / MD Nastran

Corrected Version 2004.0.4 Abstract

Frequency Response Analysis - SPCD, DPD - SFM 4276 when multiple subcases request different spc sets A frequency response problem involving enforced motion fails with SFM 4276 in the DPD module if there are multiple subcases and different spc sets are selected in the case control.

Description

Avoidance: Apply the following dmap alter: compile phase0 alter ' copy yG1\/yG2'(,-1),'' $ create only the first yg2 for dynamics ELSE if ( nskip=1 or app'freqresp' ) then $

Known Error

CR 1-14186907

Product

MSC / MD Nastran

Corrected Version 2004.0.4 Abstract

Dynamics - TLOADi, ACSRSE - Negative real values for the DELAY and DPHASE fields - UFM 316

Description

Use of negative real values for the DELAY or DPHASE fields on the ACSRCE or TLOAD1 or TLOAD2 entries results in UFM 316 in the PREFACE module.

Known Error

CR 1-14191701

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

Optimization/Design Sensitivity - DLINK - Incorrect constraints for dependent design varaibles. When an optimization job has specified a DLINK entry, the corresponding DESVAR entry has a blank DELXV field and P2 on the DOPTPRM is set to 4, the constraints for dependent design variables are printed in the f06 file incorrectly. However, these constraints are computed correctly during the approximate optimization. Avoidance: Specify a non=blank DELXV field on the dependent DESVAR entries.

Known Error

CR 1-14210501

Product

MSC / MD Nastran

Corrected Version 2004.0.4

Known Error

CR 1-14210501

Abstract

Eigenvalue Analysis/Acoustics - RESTART - Modes Unnecessarily Recalculated In V2004, if a restart is performed from a SOL 103 run with acoustics, then the fluid modes may be unnecessarily recalculated. Avoidance: Insert the following alter in SOL 103 cold start:

Description compile semodes alter 1 type parm,nddl,i,n,methf $ endalter Known Error

CR 1-14222717

Product

MSC / MD Nastran

Corrected Version 2004.0.4 Abstract

Superelement - RESTART - Unnecessarily Recalcualtes Modes A superelement restart from sol 103 to 112 may unnecessarily recalculate upstream modes for some superlements. Avoidance: Apply the following dmap alter:

Description compile sekmr alter 'endif \$ atsprt'(,-1) kchng=false $ endalter Known Error

CR 1-14223905

Product

MSC / MD Nastran

Corrected Version 2004.0.4 Abstract

Nonlinear Analysis - TEMP(LOAD), QUADR, TRIAR - Wrong Answers

Description

Temperature loads for the QUADR and TRIAR elements is not implimented correctly for nonlinear analysis. Avoidance: Use the QUAD4 and TRIA3 elements.

Known Error

CR 1-14233604

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Elements - CQUADR, PARAM,CHECKOUT,YES - Incorrect grid point weight generator output

Description

Mass for the CQUADR element is not included in the grid point weight

Known Error

CR 1-14233604 generator results when param,checkout,yes is specified.

Known Error

CR 1-14238367

Product

MSC / MD Nastran

Corrected Version 2005.1 Abstract

ESE - REPCASE - Wrong Element Strain Energy Results If there is an ESE request in the REPCASE only, the results are wrong.

Description Avoidance: Request ESE for at least one element in the primary subcase. Known Error

CR 1-14249707

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Documentation/QRG - SOL 600, PARAM,MARCPTH - Incorrect Default

Description

The MSC.Nastran V2004 indicates that the default for param,marcpth is 1. It is not, it is 0. The value of 0 indicates that marc is run within nastran and will look for the marc executable in the default installation directory.

Known Error

CR 1-14251001

Product

MSC / MD Nastran

Corrected Version 2004.0.4 Abstract

Dynamics - CAXIFi, PARAM,G - Wrong Answers If the old acoustic cavity method (see CAXIFi elements) is selected in SOL 108 or SOL 200 (with ANALYSIS=DFREQ) then PARAM,G will be ignored.

Description

Avoidance: Insert the following DMAP alter: compile sedfreq alter 'fonly=','' endalter

Known Error

CR 1-14251410

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Optimization/Design Sensitivity - RLOAD1 - Enforced Displacement, UWM 2071 (DPD2)

Description

SOL 200, analysis=mfreq, may produce incorrect results for enforced displacement specified with the RLOAD1 entry.

Known Error

CR 1-14251410 Avoidance: This problem can be avoided by expanding output request set to include the grids with enforced motion.

Known Error

CR 1-14251416

Product

MSC / MD Nastran

Corrected Version 2004.0.4 Abstract

Description

Post Processing/ACMS - PARAM,POST,-1 - Lama datablock missing from op2 file A distributed memory parallel (dmp) ACMS analysis does not write the lama table to the op2 file when param,post,-1 and param,post,ext,yes are specified. This data block is critical for post processing acoustic results and is produced in a serial run.

Known Error

CR 1-14261401

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Description

External Superelements - EXTSEOUT - Missing Output due to sparse data recovery A SOL 103 assembly run employing an external superelement created using the EXTSEOUT feature does not produce the requested output for the external SE. Avoidance: Insert PARAM,SPARSEDR,NO.

Known Error

CR 1-14267003

Product

MSC / MD Nastran

Corrected Version 2004.0.4 Abstract

Elements - MFLUID - UFM 4257 (FMXACD) User fatal message 4257 may erroneously appear for virtual mass elements (MFLUID), if the distance between two element centers is exactly equal to the RMAX value from the MFLUID record.

Description Avoidance: An avoidance is to modify RMAX (see MFLUID entry) slightly. It is recommended that the default value always be used, and this error is very unlikely. Known Error

CR 1-14270665

Product

MSC / MD Nastran

Known Error

CR 1-14270665

Corrected Version 2010.1.0 (MD R4) Abstract

Submittal - "\" in .rcf file, USER FATAL MESSAGE (pgm: nastran, fn: validate_lcl_key A back slash in the rc file or submittal line to indicate a directory path (i.e. D:\) may lead to the following fatal message *** USER FATAL MESSAGE (pgm: nastran, fn: validate_lcl_keywords) sdirectory=d:memory=500mb (e:/msc/conf/nast2004.rcf[1])

Description

Avoidance: This error can be avoided by changing the back slash to a forwared slash or by adding a " $" after the back slash as follows: sdir=d:/ or sdir=d:\ $

Known Error

CR 1-14273377

Product

MSC / MD Nastran

Corrected Version 2004.0.4 Abstract

Distributed Memory Parallel (DMP) - FREQ3,FREQ4,FREQ5 - SFM 6833 FREQ3, FREQ4, and/or FREQ5 Bulk Data entries in a DMP analysis may lead to SYSTEM FATAL MESSAGE 6833. Avoidance: Insert the following DMAP alter:

Description

compile semfreq alter ' frlgen '(,-1) if ( procid=1 ) then $ disutil lamas ,,,////3 $ else if ( procid>1 ) then $ delete /lamas,,,, $ disutil ,,,,/lamas ///3 $ endif $ procid>1 endalter

Known Error

CR 1-14284801

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Optimization/Design Sensitivity - scr=no converges slower

Description

SOL 200 with scr=no converges slower than with SCR=yes. Further investigation has found that the slow convergence was due to incorrect sensitivity coefficients supplied to optimizer.

Known Error

CR 1-14284801 Avoidance : Insert the followng alters: $ for v2001 compile pslgdv alter 'if ( dmresd'(2,-2) else $ if (seid=0) delete /delf1,,,, $ $ for v2004 and v2005 compile pslgdv alter 'if ( nndgs'(2,-2) else $ if (seid=0) delete /delf1,,,, $

Known Error

CR 1-14286512

Product

MSC / MD Nastran

Corrected Version 2004.0.4 Abstract

Distributed Memory Parallel (DMP) - SEP1X - Free Floating Grids Cause DMP to Fail in SEP1X In MSC.Nastran 2004.0.3 (released to only one client) a model with free floating grids, meaning grids that are not attached to the structure, may cause dmp jobs to fail. This includes models with grids that are only used as reference points.

Description

Avoidance: Set system(294)=2 (which will print the external IDs of those free grids, search for FREE FLOATING, and then remove the grid entries. If the grids were used as reference points, they have to be replaced by coordinates. Grids that are referenced only on a PLOTEL element are not considered free floating, so attaching the reference grids to PLOTELs is another way to avoid the problem.

Known Error

CR 1-14299201

Product

MSC / MD Nastran

Corrected Version 2004.0.4 Abstract

Description

ACMS - Multiple USETi,U6 entries not handled correctly. In ACMS, unit load degrees of freedom on the USET1 entry are forced to the residual structure. However, if there are more than one USET1 entry in the input, it only forces the points from the first entry. DOF on subsequent entries are not forced to the residual. This leads to fewer than the desired number of residual vectors when those degrees of freedom are not put into the residual structure by the automatic partitioner.

Known Error

CR 1-14305003

Product

MSC / MD Nastran

Corrected Version 2004.0.4 Abstract

SOL 600 - Large Jobs - Insufficient swap space Extremely large SOL 600 jobs may fail on some small computers with a message that indicates that they have run out of swap space.

Description

Avoidance: Other than running on a different platform, there is no avoidance.

Known Error

CR 1-14322801

Product

MSC / MD Nastran

Corrected Version 2004.0.4 Abstract

Optimization/Design Sensitivity - PARAM,XYUNIT - FORMAT ERROR 103 The error message: FORMAT ERROR 103: A POSITIVE VALUE IS REQUIRED HERE

Description

may occur in SOL 200 when PARAM XYUNIT is used to create a CSV file of the optimization results and the number of design variables is 3n+1 where n is any integer starting from zero. To date this behavior has only been observed on Linux platforms. Avoidance: Run on a different platform or add a dummy variable such that the number of variables is not 3n+1.

Known Error

CR 1-14348401

Product

MSC / MD Nastran

Corrected Version 2004.0.4 Abstract

Nonlinear Analysis (SOL 400) - MPC, RBEi, RBAR - Wrong Answers For SOL400, the solution will converge to wrong results if there are MPC constraints or linear rigid elements (RIGID=LINEAR) in the model.

Description Avoidance: There is no avoidance.

Known Error

CR 1-14352403

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Elements - CRAC3D - UFM 5469 (DUMK9D)

Known Error

CR 1-14352403 Input with more than one crac3d element will fail in Verison 2001.0.9 with UFM 5469 as follows:

Description

*** USER FATAL MESSAGE 5469 (DUMK9D) IN CRAC3D ELEMENT 21789 CONNECTION POINT G64 IS REQUIRED IF CONNECTION POINT G55 IS SPECIFIED *** USER FATAL MESSAGE 5467 (DMK9ND) CONNECTION POINT G10 OF CRAC3D ELEMENT 21789 IS REQUIRED BUT NOT DEFINED *** USER FATAL MESSAGE 5467 (DMK9ND) CONNECTION POINT G10 OF CRAC3D ELEMENT 21789 IS REQUIRED BUT NOT DEFINED *** USER FATAL MESSAGE 4660 (EHEXD) FOR ELEMENT WITH ID = 0 THE CORNER POINTS HAVE NOT BEEN SUPPLIED CORRECTLY. . . Avoidance: Use any other version, else analyse the cracks in separate runs.

Known Error

CR 1-14380804

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Acoustic Analysis - SDAMPING(FLUID) - Unexpected Answers In SOL 111, coupled fluid-structure analysis, with multiple subcases, multiple specifications of SDAMPING(FLUID) are ignored and only the first is processed. Avoidance: Insert the following DMAP alter:

Description

compile semfreq alter 'caseg'(2),'' case casem,pvtc/caseg/'comm'/s,n,nskip/////// 'k2pp'/'m2pp'/'b2pp'/'tfl'/'sdamp'/'rgyro'/'sdampf'////// 'g'/'alpha1'/'alpha2' $ endalter

Known Error

CR 1-14382607

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Optimization/Design Sensitivity - ANALYSIS=MODES and MFREQ with SPCD UFM 3046

Known Error

CR 1-14382607 An MFREQ shape optimization task that contains multiple subcases and SPCD type loads will encounter: *** USER INFORMATION MESSAGE 7559 (FRRD1A) THIS FREQUENCY RESPONSE ANALYSIS INVOLVES THE FOLLOWING TYPES OF EXCITATION -* ENFORCED ACCELERATION USING SPC / SPCD DATA *** USER FATAL MESSAGE 3046 (SQFREQ) THIS FREQUENCY RESPONSE ANALYSIS HAS NO EXCITATION SPECIFIED FOR IT. APPLIED LOADS AND ENFORCED MOTION ARE BOTH NULL. THE RESULT WILL THEREFORE BE A ZERO SOLUTION. Avoidance: The subcases must be run separately or insert the following DMAP alter:

Description compile feamode $ for V2005+ $compile fea $ uncomment in V2004 alter 'if ( nopha=','' if ( true ) then $ compile modefsrs alter 'call moders'(,-1) dbstatus phsa//s,n,nophsa $ if ( nophsa=-1 ) then $ alter 'call moders' endif $ alter 'call resveca'(,-1) if ( nophsa=-1 ) then $ alter 'call resveca'(,7) endif $ ************************ Fixed MDR4 V2010.0.0 Known Error

CR 1-14397204

Product

MSC / MD Nastran

Corrected Version 2004.0.4 Abstract

Description

SOL 600 - MATTEP - Add General Temperature-Dependent Stress-Strain Curves SOL 600 temperature-dependent stress-strain curves need to be supported for general shapes. At present such curves are limited to scale with the same slopes as the original curve vs temperature. In MSC.Nastran 2004R2 (Version 2004.0.4 and beyond) new options have

Known Error

CR 1-14397204 been added to the MATTEP entry that allows support for general temperaturedependent stress-strain curves in SOL 600.

Known Error

CR 1-14397207

Product

MSC / MD Nastran

Corrected Version 2004.0.4 Abstract

SOL 600 - DMIG - DMIG Support added to MSC.Nastran 2004R2

Description

Support for DMIG entries in SOL 600 has been added to MSC.Nastran 2004R2 (Version 2004.0.4 and beyond).

Known Error

CR 1-14397801

Product

MSC / MD Nastran

Corrected Version 2004.0.4 Abstract

Elements - CWSEAM - Incorrect Stiffness

Description

The hexa type stiffness matrix for the CWSEAM element is computed in the wrong coordinate system and this will lead to an incorrect stiffness matrix and wrong answers. The stiffness should be computed in the basic coordinate system instead of element coordinate system.

Known Error

CR 1-14405601

Product

MSC / MD Nastran

Corrected Version 2004.0.4 Abstract Description

Static Analysis - RBE3 - Lagrange RBE3 may give wrong answers The Lagrange RBE3 will give wrong results if the reference dof=123 for SOL 101. Avoidance: Specify 123456 for the reference degrees of freedom.

Known Error

CR 1-14405604

Product

MSC / MD Nastran

Corrected Version 2004.0.4 Abstract

SOL 400 - CBEAM, RBAR - CBEAMs with RBARs cause diverging solution

Description

If CBEAM elements are used with RBAR elements in SOL400 the solution may diverge.

Known Error

CR 1-14405901

Known Error

CR 1-14405901

Product

MSC / MD Nastran

Corrected Version 2004.0.4 Abstract

Restarts - DBLOCATE - UFM 477, Timestamp Error The following dblocate restart run will result in USER FATAL MESSAGE 477.

Description

Run1 : create a database. Run2 : dblocate, copy the contents of run1 and restart creating run2 database. Delete run1's database. Run3 : dblocate run2's database. This causes a UFM 477 error saying there is a timestamp error on run2.dball. Avoidance: 1) Use autoasgn=3 in run3 and manually assign the dblocated database, or 2) I did a dbdict, endjob directly into run2's database (dbs=run2) before deleting run1's database. This also avoids the error.

Known Error

CR 1-14410701

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL 400 - Solution diverges with SPCD loads and linear rigid elements for LANGLE=1,2 and SOL400.

Description

For SOL400, the solution diverges if there are SPCD loads and linear rigid elements in the deck for LANGLE=1, or 2. However, the solution will converge if LANGLE=3.

Known Error

CR 1-14412401

Product

MSC / MD Nastran

Corrected Version 2004.0.4 Abstract

SOL 600 - GRAV, CONMi - No gravity loads for concentrated masses

Description

SOL 600 gravity loading does not produce any loads for the concentrated masses (CONMi) in the Marc input deck.

Known Error

CR 1-14461909

Product

MSC / MD Nastran

Corrected Version 2004.0.4 Abstract

Transient Analysis/Enforced Motion - STATSUB - UFM 3046 in TRD1

Description

If enforced motion is specified and STATSUB is also requested in SOL 108

Known Error

CR 1-14461909 or 109 then the job may fail with USER FATAL MESSAGE 3046 Avoidance: Insert the following alter: compile sedtran alter 'call autosprt' else $ equivx lll/lyy/-1 $ ompile sedfreq alter 'call autosprt' else $ equivx lll/lyy/-1 $ endif $ endalter

Known Error

CR 1-14469102

Product

MSC / MD Nastran

Corrected Version 2004.0.4 Abstract Description

ACMS - UFM DISJOINT SUPERELEMENTS EXIST Large ACMS jobs may fail incorrectly with a message that complains about the existence of "DISJOINT SUPERELEMENTS". Avoidance: There is no avoidance.

Known Error

CR 1-14480201

Product

MSC / MD Nastran

Corrected Version 2004.0.4 Abstract

Rotor Dynamics - ROTORG - Unbalanced load in rotor dynamic module In rotor dynamic analysis , if multiple unbalanced loads are applied to points not in the a-set then loads will be ignored and wrong answers will result.

Description Avoidance: If multiple unbalanced loads exist, then make sure that all load points are in the analysis(a) set.

Known Error

CR 1-14485401

Product

MSC / MD Nastran

Corrected Version 2004.0.4 Abstract

SOL 600 - BEGINBULK Causes Failure in trelpl.F

Description

SOL 600 jobs may fail with an error in trelpl.F if BEGINBULK rather than BEGIN BULK is entered.

Known Error

CR 1-14487301

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Documentation/QRG - ECHO The 2004 release has new options for the PUNCH portion of the ECHO command. The QRG description of this command has errors in describing the new options. The PUNCH and NEWBULK describers should be changed as follows:

Description

PUNCH: The entire Bulk Data will be written to the punch file. (i.e,. omit the "in sorted form") NEWBULK: In SOL 200, a complete unsorted bulk data deck is written to the punch file with updated design model entries. (i.e., change "complete and sorted" to "a complete unsorted"

Known Error

CR 1-14523741

Product

MSC / MD Nastran

Corrected Version 2004.0.5 Abstract

Post Processing - PARAM,POST,0 - Missing Results in xdb A combine heat transfer and thermal stress analysis with param,heatstat,yes will not write both the heat transfer and thermal stress results to the xdb or op2 file for postprocessing. If using param,post, 0 to write results to the xdb file, only the temperature result are obtained. If using param,post,-1 to write the results to the op2 file, only the thermal stress result are obtained.

Description

Avoidance: Apply the following dmap avoidance; compile phase0 alter 'output2'(,-1) if ( not(heatstat='yes' and aprch=' ') ) then $ alter 'output2' endif $ alter 'ELSE IF ( (OGEOM=','' ELSE IF ( (OGEOM='YES' OR OGEOM=' ') AND not(dmpop2) and not(heatstat='yes' and aprch=' ') and ((POST=-1 or patplus='yes') AND PATVER>=3.) ) THEN $ endalter

Known Error

CR 1-14533901

Product

MSC / MD Nastran

Known Error

CR 1-14533901

Corrected Version 2004.0.4 Abstract

Description

Optimization/Design Sensitivity - NEWBULK - Incorrect/Missing Bulk Data Echo Output The NEWBULK describer on the ECHO case control command enables punching of a complete unsorted bulk data deck at the end of a SOL 200 run with updated design model data. If the original input deck contains design model data that has been input in free field form and has a continuation that has a comma in column one, the updated design model data is followed by an incorrect punch of the continuation line. Also, if the user has placed comments at the end of a line of data that is included in the design model, the comment does not get written to the punch file. Avoidance: A blank can be inserted in front of the comma on the continuation line and the correct behavior will result. Comments that are at the end of design model entries must be moved to their own line if they are to be retained.

Known Error

CR 1-14556901

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

Matrix Methods - param,inrel,-2 - Lagrange Multipliers, Incorrect matrix to factor diagonal messages When Lagrange Multipliers are used, as in param,inrel,-2, calculations in SOL 101 and several other places, large matrix to factor diagonal matrix ratios may be prined out and they may be in error.

Description Avoidance: If the "MATRIX/FACTOR DIAG. RATIO" is identical to the "MATRIX DIAGONAL" they can be safely ignored. If the run fatals, param,bailout,-1 can be used to avoid the fatal error. Known Error

CR 1-14568012

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Acoustic Analysis - ACMODL - Corrupted pch file output

Description

Acoustic analysis that specifies the CP method on the ACMODL entry may produce a corrupted (skinout) punch file.

Known Error

CR 1-14576201

Product

MSC / MD Nastran

Corrected Version 2004.0.4 Abstract

Distributed Memory Parallel - ACMS May Produce Wrong Answers in Acoustics Distributed Memory Parallel (DMP) with ACMS may produce wrong answers in Acoustics.

Description Avoidance: Use serial ACMS. Contact MSC for DMAP avoidance. Known Error

CR 1-14593609

Product

MSC / MD Nastran

Corrected Version 2004.0.4 Abstract

SOL 600 - PCOMP - Composites not Translated to Marc Correctly

Description

Composites, PCOMP entries, are not tranlated by SOL 600 to the marc input file correctly.

Known Error

CR 1-14595809

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Rotor Dynamics - UNBALNC, transient response, WTMASS, NLLOAD, imbalance

Description

PARAM,WTMASS does not change the load vector (NLLOAD output) leading to wrong answers.

Known Error

CR 1-14600924

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Static Analysis - APP HEAT, PARAM,HEATSTAT,YES, READ, MAT4 - SFM 4276 SOL 101 with APP HEAT or PARAM,HEATSTAT,YES may fail in the READ module with SFM 4276

Description

This is possible if the bulk data entry MAT4 has specific heat or density. Avoidance: Insert the following DMAP alter: compile phase1a alter 'if ( rvrvd )'(,-1)

Known Error

CR 1-14600924 rvdam=false $ rvrvd=false $ endalter

Known Error

CR 1-14602401

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Description

Submittal - SDIR must be write accessible if QUE= is specified If MSC.Nastran is submitted with QUE=NAME, then the script checks that "SDIR" is writable. In the case of QUEUES, a user may be on a headnode of a cluster, and not have write access to SDIR on the headnode, but only on the compute nodes. Avoidance: The check does NOT occur if the job is run with NODE=node_name. The check should not be there if there are queues as well.

Known Error

CR 1-14607302

Product

MSC / MD Nastran

Corrected Version 2004.0.5 Abstract

Performance - EIGRL, READ - When use_aio is on, incorrect cpu reporting leads to poor performance

Description

When use_aio=yes is specified in a Nastran 2004.0.0 on HPUX 64 platforms, it may cause inaccurate and even negative cpu usage. This may cause additional shifts in Lanczos and lead to poor performance. This problem has been fixed in Version 2004.0.5 and later system by linking against corrected libraries from HP.

Known Error

CR 1-14626001

Product

MSC / MD Nastran

Corrected Version 2004.0.5 Abstract

Aeroelastic Analysis - UFM 5259 (MAKAUMD) In aeroelastic analyis UFM 5259 may be issued without any text. Avoidance: The text should read:

Description *** USER FATAL MESSAGE 5259 (MAKAUMD) UXVEC BULK DATA ENTRY WITH ID xx INVOKED BY A AEPRESS BULK DATA ENTRY DOES NOT EXIST.

Known Error

CR 1-14627054

Product

MSC / MD Nastran

Corrected Version GL Abstract

Nonlinear - PELAST, Kn - Possible Wrong Answers If the load deflection capability (Kn) is used with PELAST in a nonlinear analysis, then the results may be incorrect. The results are dependent on the connectivity order.

Description Avoidance: Use the CBUSH/PBUSH/PBUSHT instead. If the length is nonzero, the orientation vector method must be used instead of the CD field Known Error

CR 1-14629706

Product

MSC / MD Nastran

Corrected Version GL Abstract

Nonlinear Analysis - TEMP(LOAD) - Wrong Intermediate Results Hi: This is a general limitation. For nonlinear static analysis with thermal load, all intermediate data recovery of stress and strain is not correcrt to "LINEAR" elements. The definition of "LINEAR" elements including 2 groups of elements (1) All elements have no nonlinear capability, such as CBAR, CSHEAR,..., and (2) All elements have nonlinear capability but there is no geometrical or material nonlinearity behavior applied to them.

Description

Please also see 1-16331802. Regards, Fisher ======================== In nonlinear analysis, sol 106, using temp(load) stresses and nonlinear strains are incorrect for intermediate output (intout=yes on nlparm entry). This is true for MAT1 and MAT1/MATT1 using param,epsilont,secant which is the default. Avoidance: Use param,epsilont,integral and make alfa temperature dependent if not already the case.

Known Error

CR 1-14636601

Product

MSC / MD Nastran

Corrected Version Abstract

sfm 3007, sol 111, domainsolver modes (partopt=dof) A sol 111 run on linux with dmp=2 and domainsolver modes (partopt=dof) may fail with:

Description

SYSTEM FATAL MESSAGE 3007 (READ) ILLEGAL INPUT TO SUBROUTINE MERGE This has been observed rarely.

Known Error

CR 1-14639801

Product

MSC / MD Nastran

Corrected Version 2010.1.1 Abstract

Description

Optimization/Design Sensitivity - DVPREL1, PBUSH - No Warning Message Issued When an optimization job designs a PBUSH property using a positive FID on a DVPREL1 entry that is not allowed, the program does not stop the process. The subsequent result may not be reliable. Avoidance: Use the property name instead. Such as K1 or B4.

Known Error

CR 1-14641801

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

Description

GPFDR - Error set durational processing When multi-Subcase processing was introduced to GPFDR for durational performance issues, the criteria used was the set number, not a validation to the set content. This violate the Case Control Processing re-usage for set id within the a Subcase section. An avoidance is to use unique set identification related to the set content. This will be correct in V2005.

Known Error

CR 1-14646106

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Installation - Uninstall of Nastran 2004 also uninstalls Nastran 2001.

Description

Uninstall of Nastran 2004 also uninstalls Nastran 2001. This has been

Known Error

CR 1-14646106 corrected with version 2005.0 installation/uninstall. (cdp 12/09/04) .

Known Error

CR 1-14651801

Product

MSC / MD Nastran

Corrected Version 2004.0.5 Abstract

SOL 600 - RBE3 has a limit of about 450 continuation cards

Description

For SOL 600 the RBE3 has a limit of about 450 continuation entries. Some models mave large RBE3's that exceed this limit. For such models, a memory over-run occurs and bad data is written to the appropriate section of the Marc input deck

Known Error

CR 1-14651804

Product

MSC / MD Nastran

Corrected Version 2004.0.5 Abstract

SOL 600 - TEMP(LOAD), TEMP(INIT) - Performance Problem

Description

SOL 600 has a performance problem for large models with thermal loading. This occurs when TEMP(INIT) and TEMP(LOAD) are entered. On some computer systems, such as Linux, the performance penalty is very small. On others, such as HP, the performance penalty is large. This is caused by I/O that can be performed in a different way. For the large where this error was discovered, the run took more than 60 minutes to create the model on HP when it should have only take a couple of minutes. The problem has been fixed in Nastran 2004.0.5 on the Nastran 2004r2 cd.

Known Error

CR 1-14667001

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

Elements - NSM1, PSHELL - Missing mass, Wrong Answers The NSM1 command does not work on shell elements.

Description

Avoidance: User the NSM or NSML2 commands.

Known Error

CR 1-14674804

Product

MSC / MD Nastran

Corrected Version Abstract

Optimization/Design Sensitivity - CWELD - Projection not updated, Poor Answers, Poor Convegence

Known Error

CR 1-14674804

Description

A projection is made between the diameter of a CWELD element and its associated shell elements to keep the symetrical connection between the weld and the shell elements. The procedure is implemented by MODGM2 and carried out in the IFP stage. As the diameter of a CWELD element is designed during the optimization phase, the projection of the CWELD needs be updated. Secondly, if the grid locations of shell elements are designed, the projection of weld and shell elements also needs to be updated during the design cycle. Therefore, the modgm2 module should be included in the design cycle.

Known Error

CR 1-14717802

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

Eigenvalue Analysis - EIGR, GIV, HOU - Poor performance in wilvecd

Description

Householder and Givens eigenvalue methods may get poor performance on HP and Linux IA64 systems.

Known Error

CR 1-14720908

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Optimization/Design Sensitivity - OUTPUT4 - Extra records in the output4 dscm2 datablock The rayleigh quotient approximation used for eigen/freq responses in SOL 200 results in three columns in the DSCM2 matrix for each response. When these results are printed to the .f06 file, these additional columns are stripped off but when they are written to a file using OUTPUT4, they are still there. Avoidance: This alter moves the partitioning of the DSCM2 matrix so that is applies to the OUTPUT4 requests as well.

Description COMPILE EXITOPT $ alter 'sdsc' IF (RQANO) THEN $ $ REMOVE SPAWNED GENERALIZED STIFFNESS AND MASS DSA FROM DSCM2 $ PARTN DSCM2,MRQA,/DSCM2NGS, DSCM2GS,,/1 $

Known Error

CR 1-14720908 EQUIVX DSCM2NGS/DSCM2/ALWAYS $ endif $ alter 'rqano'(3),'rqano'(3,3) $ endalter

Known Error

CR 1-14762201

Product

MSC / MD Nastran

Corrected Version 2004.0.5 Abstract

SOL 600 - Marc CONTROL block 3a is not supported

Description

The SOL 600 Marc CONTROL block 3a is not supported. This was intentional in SOL 600 versions before Nastran 2004.0.5 because some version of Marc did not support it. This is only important if different tolerances for displacment and residual are needed.

Known Error

CR 1-14762903

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Description

Optimization/Design Sensitivity - Superelements - Slow Convergence If an eigenvalue optimization task contains superlements and SCR=NO is used, convergence to the optimum design will be slowed due to incorrect sensitivity calculations in the DOM9 module. This only occurs if the Rayleigh quotient approximation is used in the approximate optimization task for the eigenvalue response. Avoidance: Apply the direct (ATTB=1) or inverse (ATTB=2) approximation technique for the eigenvalue response or insert the following alter: compile desopt alter 'cdelk,cdelm,cdelb'(3),'' delete /cdelk,cdelm,cdelb,delgs,delgm $

Known Error

CR 1-14763501

Product

MSC / MD Nastran

Corrected Version 2004.0.5 Abstract

Elements - QUADR - Incorrect Output Coordinate System

Description

The default stress/strain output coordinate system for QUADR is not the one defined in Quick Reference Guide. It is the material coordinate system with theta=0.0.

Known Error

CR 1-14777101

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

Large Problems/Frequency Response - DPD - SFM 4276 (READ) EC 3021 (DPD) Very large SOL 111 jobs may fail with the message:

Description

SYSTEM FATAL MESSAGE 4276 (READ) ERROR CODE 3021 (DPD) Avoidance: There is no known avoidance.

Known Error

CR 1-14777104

Product

MSC / MD Nastran

Corrected Version 2004.0.6 Abstract

Miscellaneous - linux, no space left on device, job does not abort

Description

On linux systems, if there is no space left on device, the job does not abort and the job may hang.

Known Error

CR 1-14779931

Product

MSC / MD Nastran

Corrected Version 2005 Abstract Description

Nonlinear Analysis - plasticity - Failure to converge or wrong answers In nonlinear analysis, sol 106, Nastran does not handle a hardening slope change after the 1st hardening slope in plasticity analysis. This may lead to a failure to converge or wrong answers.

Known Error

CR 1-14813801

Product

MSC / MD Nastran

Corrected Version 2004.0.5 Abstract

Description

Optimization/Design Sensitivity - SFM 6296 (QMATR) Unable to locate datablock dtos2j with The message: SYSTEM FATAL MESSAGE 6296 (QMATR) unaable locate datablock dtos2j attribute dptye: xxxx may occur if the bulk data file contains a mixture of DVPRELi, DVMRELi and DVRELi entries and the DESVAR case control command is used to select a set of design variables that do not includ any of a partcular property type.

Avoidance: Either remove the unneeded DVxRELi entries or include a DESVAR

Known Error

CR 1-14813801 that references each property type or apply the folowing dmap alter when DVMRELi's are the unneeded entries and the deck contains needed DVPRELi's and DVCRELi's. A similar dmap can be constructed for other scenarios:

compile predom alter 'dopr1 ' message //'protyp = '/protyp $ $ For the case of all the DESVARs referenced on DVMREL1 entries are NOT selected by DESVAR command protyp = 3 $ For the case of all the DESVARs referenced on DVPREL1 entries are NOT selected by DESVAR command $protyp = 7 - 1 $ For the case of all the DESVARs referenced on DVCREL1 entries are NOT selected by DESVAR command $protyp = 7 - 2 Known Error

CR 1-14817201

Product

MSC / MD Nastran

Corrected Version 2004.0.5 Abstract

SOL 600 - Not all values for SOL 600 Marc's AUTO INCREMENT are properly translated Not all values for SOL 600 Marc's AUTO INCREMENT are properly translated form NLSTRAT AIxxxxx entries.

Description Avoidance; Other than manually editing the marc input file there is no avoidance. Known Error

CR 1-14860909

Product

MSC / MD Nastran

Corrected Version 2004.0.5 Abstract

Description

Nonlinear Analysis - CBUSH with local coordinate systems cause convergence problems A nonlinear analysis with CBUSH elements with their grid points defined in local coordinate system may have convergence problems. with bushes that have their grid points defined in loc Avoidance: The displacement coordinate systems for points connected by cbush elements in an nonlinear analysis should be the same.

Known Error

CR 1-14861414

Known Error

CR 1-14861414

Product

MSC / MD Nastran

Corrected Version 2004.0.6 Abstract

Description

Rotordynamics - RSPINR, ROTORDR2 - Floating Point Exception or Missing Message If the SPEEDi field is defined incorrectly on the RSPINR entry (e.g., defined as an integer instead of a real), then depending on the machine, the proper error message may not be issued. On some machines, the job may stop without any messages. On other machines, the job may stop with a floating point exception. Avoidance: Correct the offending entry.

Known Error

CR 1-14872738

Product

MSC / MD Nastran

Corrected Version 2004 Abstract

Poor zero frequency modes (SOL103) when model is prestressed by STATSUB.

Description

There are cases where some modal frequencies of an unconstrained and prestressed structure should be zero. These should occur when the forces remain in equilibrium after virtual displacement, which means the loads rotate with the model. Nastran does not get good zeros for these modes due to some inconsistency between the way the loads and elements are formulated. On the other hand, models with FORCE loads that do not rotate with the model are not expected to have zero frequency for modes that involve rotation.

Known Error

CR 1-14895708

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

SOL 600 - CBAR - Null OUTPUT2 file is created when model consists of on CBARs The SOL 600 t16op2 translator (outr=op2 option) requires that elements with stress and strain be present. If a model consists entirely of CBAR and CBEAM elements that only generate internal forces, the generated op2 file will be null and the following message will be written to the f06 file:

Description *** SYSTEM FATAL MESSAGE 6551 (INPTX2) AN END-OF-FILE WAS DETECTED ON UNIT 11 DURING BINARY INPUTT2 PROCESSING PROGRAMMER INFORMATION: 1. A KEY VALUE WAS BEING READ

Known Error

CR 1-14895708 2. THE LAST KEY VALUE READ: 0 0*** FATAL ERROR. 0 NO. FORTRAN RECORDS READ = 0 NO. FORTRAN WORDS READ = 0 0FATAL ERROR

Known Error

CR 1-14923601

Product

MSC / MD Nastran

Corrected Version 2004.0.5 Abstract

Optimization/Design Sensitivity/DMP - SOL 200 w/DMP Fails due to DISUTIL non-execution

Description

A SOL 200 job with DMP, DOMAINSOLVER MODES (part=dof) failed due to non-execution of a DISUTIL call on the master. The non-execution was caused by the restart logic (sys109).

Known Error

CR 1-14928501

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Part Superelements - TOL on SEBULK and SECONCT entries uses SQRT(TOL) instead of TOL

Description

For Part Superelement connections via SEBULK or SECONCT, the TOL field defines the SQRT of the search distance instead of the linear search distance.

Known Error

CR 1-14932102

Product

MSC / MD Nastran

Corrected Version 2004.0.5 Abstract

Optimization/Design Sensitivity - External SE - SFM 4276 In a SOL 200 optimization analysis run with external superelements and shape design variable, the job may fail in the 2nd design cycle with the following messages: *** SYSTEM FATAL MESSAGE 4276 (PACK) ERROR CODE 105 PID= 0

Description Avoidance: Insert the following DMAP alter $ compile update,list $ alter 'dbstatus selist'(,-1) $ type parm,nddl,i,n,zuzri1 $ alter 'if ( noselist',''(,1) $

Known Error

CR 1-14932102 if ( noselist=1 and zuzri1>0) ) then $ if ( begsup or (noselist>0 and zuzri1>0) ) then $ $ compile desopt,list $ alter 'call update'(,-1) $ type parm,nddl,i,n,zuzri1 $ zuzri1 = shapeopt $

Known Error

CR 1-14949104

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Distributed Memory Parallel/Optimization - MODTRK - UFM 6458 A DMP optimization job that requests mode tracking will fail in module MODTRK with UFM 6458 (MTD0RD) complaining the requested mode does not exist.

Avoidance: Apply the following dmap alter

Description

compile fea list alter 'IF ( MODETRAK>0 ) then','' IF ( MODETRAK>0 and PROCID 0 and PROCID 0 ) call CFORCE1, MSS,,M2Ss,,BSS,,B2Ss,,KSS,K4Ss,,K2Ss,,,kdss,,, ,,vspc,uset/ mss1,bss1,kss1,,,,/ APP/APP/'spcforce' $

Known Error

CR 1-15567801 alter 'call cforce1'(3),'' CALL CFORCE1 MMG,,M2MG,,BMG,,B2MG,,KMG,K4MG,,K2MG,,phig,kdmg,,, ,,vmpc,uset/ MMG1,BMG1,KMG1,,,,/ APP/APP1/'mpcforce' $ alter 'call cforce1'(4),'' CALL CFORCE1 MMy,,M2My,,BMy,,B2My,,KMy,K4My,,K2My,,, kdmy,,,,,,uset/ MMy1,BMy1,KMy1,,,,/ APP/APP/'mpcforce' $ compile cforce alter 'call cforce1','' call CFORCE1 MXY,,M2XY,,BXY,,B2XY,,KXY,K4XY,,K2XY,,uy,kdxy,,,,, vxpc,uset/ mxy1,bxy1,kxy1,,,,vxpc1/ APP/APP1/forctype $ endalter

Known Error

CR 1-15573108

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Nonlinear - CBUSH1D, shocka - Possible Wrong Answers

Description

On the PBUSH1D entry the requirement is as follows: For a linear spring K a default value of 0.0 is allowed by not specifying the K entry. For a linear damper C a default value of 0.0 is allowed by not specifying the C entry. If any nonlinearity is specified, (SHOCKA, SPRING, DAMPER, GENER), K>0 is required. If K is not provided in the presence of any nonlinearity, the element will behave as a linear element.

Known Error

CR 1-15641036

Product

MSC / MD Nastran

Correcte GL d Version Abstract SOL 400 - PARAM,POST,0, DBC Module - SWM 6065 (DBC) There are two problems in this CSR --Descripti (1) The subDMAP, nonlin, of SOL 400 does not handle the NLSTRESS correct on in DBC module(s) in the PHASE 2 before calling SUPER3 module when ANALYSIS=NLSTAT.

Known Error

CR 1-15641036 (2) The current logic of DBC does not recognize "SUBCASE-STEP" case control structure that only uses in SOL 400. I have already fixed problem (1) in V2006t1. We may need DBC expert in problem (2) - I have talked to KKK and sent some outputs to him for suggestion. I will hold this CSR before KKK has time to look into it. 04/21/2005 CJY ====================================================================== ============== SOL 400 encounters a problem processing results in the DBC module and issues the following message: *** SYSTEM WARNING MESSAGE 6065 (DBC) *** DBCMSG ERROR MESSAGE 14 FROM SUBROUTINE DBCROL UNABLE TO OPEN INPUT RELATION NLLF RETURN CODE = 1. *** SYSTEM WARNING MESSAGE 6065 (DBC) *** DBCMSG ERROR MESSAGE 14 FROM SUBROUTINE DBCROL UNABLE TO OPEN INPUT RELATION NLLF RETURN CODE = 1. Avoidance: Use PARAM, POST, -1 and the output2 file.

Known Error

CR 1-15653501

Product

MSC / MD Nastran

Corrected Version Abstract

Description

ACMS - DISPL(PLOT)=ALL, PARM,POST,0 - Missing Eigenvector results in xdb If "param,post,0" is specified with ACMS (serial or parallel), and "DISPL(PLOT)=ALL" is specified, then the XDB file will not contain the EIGENVECTORS. Note, that the EIGENVALUES are there, but not the mode shapes. Avoidance: The eigenvectors will be written to the output2 file if param,post,-1 is selected.

Known Error

CR 1-15654005

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

SOL 600 - RBE2/RBE3 nodes are not included in all SOL 600 domains for Parallel Processing

Description

RBE2/RBE3 nodes are not included in all SOL 600 domains for Parallel Processing.

Known Error

CR 1-15654005 Usually all REB2/RBE3's must be included in all domains and all grid points associated with them must also be included in all domains, othewise the job will diverge.

Known Error

CR 1-15664507

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Nonlinear Heat Transfer - Excessive Output Heat transfer, sol 159, may place the: NON-LINEARITERATIONMODULEOUTPUT

Description

for each timestep on a different page. If printed this wastes paper and it also has the potential of doubling the output because page header information is repeated for each page.

Known Error

CR 1-15689201

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

SOL 600 - RFORCE is not translated to Marc properly

Description

SOL 600 RFORCE is not translated to Marc properly. It needs distributed load code 105 rather than 100 or 103.

Known Error

CR 1-15689204

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

SOL 600 - MARCIN (include file) missing data - Nastran aborts

Description

The SOL 600 MARCIN (include file) may result in missing data and may cause Nastran to abort.

Known Error

CR 1-15721126

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

Heat Transfer Analysis - axi-symmetric elements only - UFM 4016 Radiation heat transfer analysis with axi-symmetric elements may fail with the following messages:USER FATAL MESSAGE 4016.

Description ^^^ USER INFORMATION MESSAGE 9048 (NLSTATIC) ^^^ LINEAR ELEMENTS ARE CONNECTED TO THE ANALYSIS SET (A-SET).

Known Error

CR 1-15721126 *** USER FATAL MESSAGE 4016 (GETEMP) THERE ARE NO TEMPERATURES FOR RADBC ELEMENT 100011 IN SET 1 Avoidance: Add a dummy property entry as follows: pshell,1,1,1.0

Known Error

CR 1-15721173

Product

MSC / MD Nastran

Corrected Version 2005.1 Abstract

Nonlinear Heat Transfer - CHBDYG, NLITER - Divide by Zero In SOL 153 with radiation, if the initial temperature guess is not close to the final temperature, the analysis may fail with a divide by zero or the Nonlinear Iteration Output will indicate extremely large epsilons as follows:

Description

1 9.9000E+01 1.2246E+49 1.2246E+49 1.0000E-01 2.3162E+49 1.0000E+00 -1.2212E+49 -1.2212E+49 0 0 2 1 2 9.9000E+01++++++++++++++++++++++++++++++++++++ 5.1517+245 1.0000E+00 0.0000E+00 0.0000E+00 0 0 1 1 3 9.9000E+01???????????????????????????????????????????????? 1.0000E+00 0.0000E+00 0.0000E+00 0 0 0 1 Avoidance: Specify a better value for tempd.

Known Error

CR 1-15731520

Product

MSC / MD Nastran

Corrected Version Abstract

Rigid Elements/Superelements - QSET, RIGID=LAGRANGE - SFM 6143 (DUPART) Using the new Lagrangian rigid elements (RIGID=LAGRANGE) together with QSET entries will give

Description

*** SYSTEM FATAL MESSAGE 6143 (DUPART) THE SIZES OF THE INPUT MATRICES AND THE DOF SETS ARE INCOMPATIBLE. SPECIFICALLY: The number of columns in KVF is not equal to the size of the S+Q+B-set Using RIGID=LAGRANGE with superelements gives the message: BIOMSG: ERROR 201 HAS OCCURRED IN ROUTINE WRITE , FILE INDEX = 0.

Known Error

CR 1-15731520 Avoidance: Do no use RIGID=LAGRANGE with superelements or qsets.

Known Error

CR 1-15738901

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Documentation/QRG - EQUILIBRIUM - Ignored in SE models

Description

Remark 3 of the EQUILIBRIUM Case control command in the QRG should indicate that the EQUILIBRIUM commnad produces no output in the presense of superelements.

Known Error

CR 1-15742849

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Description

Rotor Dynamics - UNBALNC - UFM 7813, floating point exception When the correction option (CFLAG) is used on the UNBALNC entry in rotor dynamics, the grid specified on the UNBALNC entry must be in the aset. Otherwise, UFM 7813 will be issued in some cases, which is the correct message. In other cases, the job will fail with floating point exception. Avoidance: Make sure that the specified grid point is in the aset

Known Error

CR 1-15742867

Product

MSC / MD Nastran

Corrected Version 2004.0.7 Abstract

DDAM - missing output in MSC.FEA When using the new DDAM option in MSC.FEA, the results are missing.

Description

Avoidance: The DDAM and DDAMOUT subdmaps need to be replaced. The error is corrected in Version 2004.0.7 which is only available on the FEA 2004 R2 that is scheduled to be released by the end of May 2004. The error is also corrected in MSC.Nastran 2004.5 scheduled to be released June 15, 2004.

Known Error

CR 1-15782011

Product

MSC / MD Nastran

Corrected Version GL Abstract

Error when rigid body modes, v1, nd are used and v1 is low

Known Error

CR 1-15782011

Description

Occasionally a FACTOR ERROR is reported when the mode is very close to the value of V1 on the EIGRL entry. This can be avoided by changing V1.

Known Error

CR 1-15795828

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

SOL 600 - BCPARA - FTYPE default of coulumb friction is not translated

Description

If FTYPE is not specified on the BCPARA entry no Defaults are used even though the Quick Reference Guide mentions indicates that the default is Coulomb. Avoidance: Explicitly specify FTYPE on the BCPARA entry.

Known Error

CR 1-15831209

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Nonlinear Analysis - ESE - Wrong Answers with INTOUT SOL 106, nonlinear analysis, may create incorrect nonlinear ESE when the 9th field of NLPARM bulk data card, INTOUT, is not set to ALL in Version 2004 and earlier releases.

Description Avoidance: Specify INTOUT=ALL. It has been fixed in V2005.0.0 Known Error

CR 1-15831507

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Frequency Response - SUPORT - SFM 6424 and 6144 Direct Frequency response with SUPORT entries may fail with the messages:

Description

SYSTEM FATAL MESSAGE 6424 (DFNSB) THE NUMBER OF ROWS IN THE LOAD VECTOR AND THE FACTOR MATRIX ARE INCOMPATIBLE LOAD VECTOR ROWS = 2536 FACTOR MATRIX ROWS = 2537 SYSTEM FATAL MESSAGE 6144 (MERGE1) THE SIZES OF THE INPUT MATRICES AND PARTITIONING VECTORS ARE INCOMPATIBLE. SPECIFICALLY: The number of rows in DAY is not equal to the number of zeros

Known Error

CR 1-15831507 in partitioning vector VAY User Information: Size of input matrices and partitioning vectors: DAY : Rows= 2537 by Cols= 1 VAY : Rows= 2537 no. of non-zeros= 1 no. of zeros= 2536 0 Avoidance: compile sedfreq alter 'call mmfind1','' type parm,nddl,char8,n,ltset,llset $ UPARTN USET,Kaa/KLL,,,/ltset/llset $ UPARTN USET,maa/mLL,,,/ltset/llset $ CALL MMFIND1, Kll,Mll,USET,SILS,EQEXINS,,bgpdts/ MECHA,phir,vspc,lll/ s,mmech/'l '/false $ endalter

Known Error

CR 1-15842401

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

SOL 600 - Multiple NLSTRAT entries result in fatal message

Description

Even though multiple NLSTRAT entries are legal, SOL 600 gets a FATAL ERROR when more than one NLSTRAT is defined. Normally there needs to be one NLSTRAT per subcase with an additional one with ID=0 for Marc's phase zero if any at all are entered.

Known Error

CR 1-15847916

Product

MSC / MD Nastran

Corrected Version GL Abstract

Nonlinear Analysis - NLPARM - Incorrect Convergence Message

Description

Nonlinear analysis, SOL 106, may issue the message that the "SOLUTION HAS CONVERGED" even though there are large residual forces which is evidence that the solution is not converged. You should look at the error measures to see if convergence really occurred.

Known Error

CR 1-15848202

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

SOL 600 - Memory request of ... words failed / RSSCON not supported

Description

In Version 2004 solution 600 may fail with the message: memory request of

Known Error

CR 1-15848202 83137782 words failed during the translation phase - no Marc input file gets created. Avoidance: Increasing the memory may not allow the problem to be solved. Running with a very large memory requested resulted in a marc input deck being created and the following message being written to the f06 file: TRANSL WARNING - RSSCON is not supported by the internal Marc translator. Marc will not be executed.

Known Error

CR 1-15848212

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

Elements - STRESS, PSOLID, CHEXA - Stress at Gauss points not available for c IN=2

Description

Writing out the stresses of CHEXA elements at the Gauss points for IN=2 is not possible. Stress at the grid points will be output.

Known Error

CR 1-15854501

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Submittal - node= - V2004 Windows missing nastran.rmt file The PC version of v2004 (both r1 and r2) does not include the nastran.rmt file (.../msc/msc2004/i386). This means that the "node=" option does not function.

Description

Workaround is to copy the one from v2001 (however there are issues with that file as well as you need to include a line that reads: jidtype=%jidtype% as a minimum - this is addressed in a separate CSR - see 1-15854504)

Known Error

CR 1-15854504

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Submittal - UFM, Input file does not exist

Description

While using "node=" command to submit from Windows to unix, the job will fail if the extension of the input file ( .bdf for example) does not match the "jidtype" setting on the remote machine. This error persists even if the "jidtype=bdf" keyword is used on the launching PC side.

Known Error

CR 1-15854504 Avoidance: If the following line is added to the PC's nastran.rmt file, then the jidtype keyword is passed thru correctly and the job recognizes the keywords and will run correctly: jidtype=%jidtype% Note that the "nastran.rmt" file itself is missing completely from the 2004 (r1 or r2) installations. The jidtype command above is in the standard nastran.rmt file for Windows. When it is included in the delivery, this error will be eliminated.

Known Error

CR 1-15862001

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

SOL 600 - SOL 600 incorrectly checks out a nastran nonlinear license

Description

A SOL 600 job may incorrectly check out a nastran nonlinear license as evidenced by the following message in the log file. Acquired 100 licenses for Group CAMPUS (MSC.Nastran Nonlinear)

Known Error

CR 1-15879701

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

SOL 600 - TEMPP1 & TEMPRB may produce incorrect POINT TEMP Marc input leading to wrong answers

Description

SOL 600 TEMPP1 & TEMPRB may produce the wrong POINT TEMP in the Marc deck leading to wrong answers.

Known Error

CR 1-15895505

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Description

Complex Eigenvalue Analysis - CLAN - Wrong Answers In Version 2004, complex Lanczos may produce bad answers if the block size is automatically augmented. The block size is only augmented when the number of repeated roots is greater than the block size or the solver is unable to converge and this rarely occurs in real world models. Avoidance: The problem can be avoided by setting system(108)=8.

Known Error

CR 1-15907201

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

SOL 600 - Eigenvalue analysis after a nonlinear solution with contact gives wrong results

Description

SOL 600 eigenvalue analysis after a nonlinear solution with contact gives wrong results for the nonlinear portion of the job as well as the eigenvalue portion.

Known Error

CR 1-15923905

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

Documentation/SOL 600 - BCBODY - UFM 316 If the documented text of "3D" is entered into the "DIM" field (field 3) of the BCBODY entry, then MSC.Nastran 2004 and 2004r2 fatal out with a UFM 316 format error as it tries to read the "d" as part of an exponent instead of as a character as documented.

Description

Avoidance: Leave this blank (since 3 is the default) or specify just the number "3". BCBODY,1 $ Default is OK BCBODY,2,3 $ Using a number is OK BCBODY,3,3D $ Gives UFM on "3D" field Running even SOL 100 with the above as the bulk data file will demonstrate the problem

Known Error

CR 1-15925501

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

External Superelements - EXTSEOUT - SFM 4276 (BLDPK) EC 211 Large external superelement jobs may fail in the MERGE1 module with the message:

Description SYSTEM FATAL MESSAGE 4276 (BLDPK) ERROR CODE 211 PID= 0; f04: EXTOUT 166 UMERGE1 BEGN BLDPK TERM Known Error

CR 1-15944704

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

Frequency Response - QSET, ASET1 - UIM 7588, SFM 6144

Known Error

CR 1-15944704

Description

In SOL 108 with modal reduction (ASET1, QSET) the GKAM module issues USER INFORMATION MESSAGE 7588 indicating the number of modes that are retained. The number of modes indicated retained is actually the number of modes calculated and the then number of modes calculated is actually the number of q-set degrees of freedom. The residual vectors are subsequently thrown away and later in the solution MERGE1 fails because of incompatibility of datablocks DAY and VAY.

Known Error

CR 1-15950512

Product

MSC / MD Nastran

Corrected Version 2004.0.7 Abstract

SSSALTER - ddam - Wrong Answers The NRL summing convention may not be used due to an inconsistent parameter name used in the ddam* sssalter

Description Avoidance: Download the latest v2001 alter (ddamall.v2001) from our website. This alter replaces the ddama and ddamba alters. Known Error

CR 1-15950532

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Elements - CTRIAX6 - Incorrect Stress Label

Description

When using axisymmetric elements, vonmises stresses are labelled as octahedral stresses. Only the labels are incorrect, the values are correct.

Known Error

CR 1-15962101

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

Elements - CWELD, CFAST, PFAST - Wrong mass when lumped mass specified in field MASS

Description

If the MASS field of the PFAST entry is populated with a value, the mass added is much larger than the lump mass specified. PARAM,GRDPNT,0 reports different masses in different directions and the eigenvalue analysis fails.

Known Error

CR 1-15972201

Product

MSC / MD Nastran

Known Error

CR 1-15972201

Corrected Version 2007.0.0 Abstract

Complex Eigenvalue Analysis - EIGC - 3003 (CEAD) Complex Inverse Power may fail with the message below when the bulk data input also contains an EIGC entry that references the CLAN method.

Description

*** SYSTEM FATAL MESSAGE 3003 (CEAD) ATTEMPT TO READ PAST THE END OF A LOGICAL RECORD IN DATA BLOCK SCRATCH (FILE 310) IN SUBROUTINE CINVPR FATAL ERROR Avoidance: Remove the unused EIGC entry.

Known Error

CR 1-15994609

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

P-elements - GMINTC and GMINTS - SFM 4276 EC 3021 If GMINTC and GMINTS Bulk Data entries are both present in the model then the run will terminate in the GP0 module with:

Description

*** SYSTEM FATAL MESSAGE 4276 (READ) ERROR CODE 3021 PID= 0 Avoidance: There is no avoidance.

Known Error

CR 1-16017810

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract Description

Documntation/QRG - RCROSS - RCROSS Case Control Command In the QRG, there is an error in the description of the RCROSS case control command. It must read CORF instead of CROF. If CORF is mistyped, then the default PSDF is used, and no message is issued.

Known Error

CR 1-16026003

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

Description

SOL 600 - Gasket materials combined with other solid element materials generate error in Marc SOL 600 Gasket materials, MATG, combined with other solid element materials generate error in Marc.

Known Error

CR 1-16028004

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

Optimization/Design Sensitivity - UFM 3001: Datablock CASEDM does not exist The fatal message USER FATAL MESSAGE 3001 DATABLOCK CASEDM DOES NOT EXIST

Description

can result when eigenvector senstivities are requested and the only RTYPE that is used is FORCE. Avoidance: An avoidance is to add other RTYPE's (DISP,STRAIN,ESE,STRESS or TOTSE) that invoke eigenvectors with an id that is equal to or greater than the highest ID appearing on a DRESP1 with RTYPE=FORCE

Known Error

CR 1-16028303

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Description

Transient Analysis - SPCD - Wrong Answers with sparse data recovery. Sparse data recovery usage in transient analysis (both SOL 109 and SOL 112) employing SPCD enforced motion will give wrong answers if the base displacement or velocity is non-zero. This should not affect enforced acceleration scenarios, but may seriously affect enforced displacement or enforced velocity scenarios.

Avoidance: Specify sparsedr=no. Known Error

CR 1-16038804

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Documentation - DMAP Programmer's Guide Aerodynamic Module examples are obsolete

Description

In the DMAP Programmers Guide, the description of the aerodynamic modules is up to date. However, most of the examples still show the old argument lists, e.g. ADG, AMG, ...

Known Error

CR 1-16060036

Product

MSC / MD Nastran

Known Error

CR 1-16060036

Corrected Version 2004.5 Abstract

Description

Frequency Response - METHOD - UFM 9056, METHOD Command required in all subcases In all previous versions of Nastran, under sol 111, the METHOD command was required only in the first subcase. In Version 2004 if multiple subcases are specified in frequency response but a METHOD command is not specified in all subcases the job will fail with the message: USER FATAL MESSAGE 9056 ( MODEFSRS) NO METHOD COMMAND WAS SPECIFIED IN THE CASE CONTROL SECTION.

Known Error

CR 1-16074001

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Dynamics/Enforced Motion/DMP/Acoustics - SFM 6144 (PARTN1) Acoustic models with enforced motion in DMP may fail with the message:

SFM 6144 (PARTN1) Size of input matrices & partitioning vector incompatible Columns of PHSA0 not equal to rows of VR Description Avoidance: Apply the following dmap avoiance: compile modefsrs alter 'if ( relmtn )'(2),'' if ( relmtn and not(procid>1 and (fdmodes or mdmodes)) ) then $ endalter Known Error

CR 1-16090301

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

DMAP - MATOFP module - no print control, ignores paging, uses CARDNO The MATOFP module has several deficiencies:

Description

1. no print control. 2. ignores paging 3. uses old CARDNO processing Avoidance: There is no avoidance.

Known Error

CR 1-16096104

Known Error

CR 1-16096104

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Enforced Motion, SOL 109 - Unexpected Spikes in Acceleration

Description

Direct enforced motion with prescribed displacements (SOL 109) may result in unexpected acceleration spikes at the beginning and end of the enforced displacement. Enhancements to enforced motion have corrected this problem in version 2005.

Known Error

CR 1-16107901

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

Optimization/Design Sensitivity - SPCD, MTRAN - Wrong answers The new relative motion formulation is not supported in SOL 200 for ANALYSIS=MTRAN. (This is because the TRD2 module does not support the new initial condition capabilities). Avoidance: A direct transient solution should be selected.

Known Error

CR 1-16107905

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

DMAP - MATMOD Option 40 - Poor message and wrong answers MATMOD Option 40 has several errors: 1. Incorrectly issues the following message in the f04: *24* Wrttrl Warning - Trailer type of terms for indexed matrix 201 is incorrect: 0. An automatic update has been made. *24*

Description

2. Incorrectly issues SWM 7598 when doing parameter conversion from single to double precision. 3. Does not ouptut the matrix in machine precision if I1 is purged and TYPE parameter is not consistent with machine precision. 4. SFM 6918 and 6920 are fatal errors but do not terminate the run. 5. If output is purged then there is no fatal.

Known Error

CR 1-16107905 6. NZWDS and DENSITY in the trailer may be incorrect. Avoidance: There is no avoidance.

Known Error

CR 1-16109501

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

Documentation/QRG - Nonlinear, PSOLID, TETRA - Nonlinear Supports 5-10 noded TETRA

Description

The PSOLID entry description in the V2001 and V2004 Quick Reference Guide incorrectly indicate that nonlinear is not supported for the 5-10 noded TETRA element.

Known Error

CR 1-16128001

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

Performance - matmod option 16 on hpux

Description

Bad performance of matmod option 16 to punch DMIG has been reported for Nastran 2004 HPUX 2004 systems.

Known Error

CR 1-16132601

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

Data Recovery - ESE ouput for DMIG missing with SETP

Description

When SETP case control is used to combine existing sets in a model with DMIG(s), the DMIG output maybe be missing in the ESE output.

Known Error

CR 1-16132609

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

Data Recovery - ESE/EKE output printed twice when SETP used

Description

When the SETP case control command is used to combine existing SETs, and more than one type of output is requested among ESE, EKE and EDE, the output may be printed twice.

Known Error

CR 1-16143401

Product

MSC / MD Nastran

Known Error

CR 1-16143401

Corrected Version 2004.5 Abstract

Multilevel Superelements - Upstream generalized coordinates are discarded. If KOA is null, which can happen on collector superelements that have no physical boundary points, the coefficients for the generalized coordinates of the upstream superelements may be discarded. Avoidance: An alter that avoids this problem for non-inertia relief runs follows:

Description $ remove line 72 in sekr $ 72 IF ( NOT(STATICS) AND $((XRESVECO='NO' AND XRESVIRO='NO' AND $ INRLM>-1)OR $ SEID=0 OR SEID=FLUIDSE) ) THEN $ alter 72,72 $ if (not statics or seid=0) then $ Known Error

CR 1-16148146

Product

MSC / MD Nastran

Corrected Version Abstract

Nonlinear Analysis - CREEP, tref, PSHELL - Poor Answers with Plane Strain

Description

In nonlinear analysis, plain strain elements give slightly different results with different reference temperatures, tref, even though the creep is set to zero. The observed differences are small. The exact cause is under investigation.

Known Error

CR 1-16148301

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

Optimization/Design Sensitivity - MFREQ/DFREQ, Superelements - Infinite Loop MFREQ/DFREQ SOL 200 optimization jobs may encounter an infinite loop condition if the number of records in FRQPRP is larger than NZ1. This scenario is most likely to happen when superelements are utilized and the number of subcases is high.

Description

Avoidance : Use the following DMAP alter only if the design model is in the residual (debug_dsad2.alter). compile descon $ alter 'dsad ','' $ DSAD RSP1CT,R1TAB,RESP12,OBJTAB,CONTAB,BLAMAX,LAMASX, CLAMAX,DIVTAB,AUXTAB,STBTAB,FLUTAB,OUGVS1,OESS1,

Known Error

CR 1-16148301 ,OEF1AA, , , ,OQGS1,DSCREN,XINIT, tabdeq,COORDN,OLX, FRLSE, FRQRSP,CASEDS,CASEm, , OPTPRM,DVPTABF,PROPIF,BGPDTS,DNODEL,WGTM, , , ,resp3,rmstab,rmsval, UGXF, QGXF, QMPXF, UHXF, , , , ,MODRSP,CASEDMX,PHGX, , , ,upsdtx, RQATAB,RESP12X,RESP3X/ R1VAL,R2VAL,RSP2R,R2VALR,CVAL,CVALR,OBJTBR,CNTABR, R1TABR,R1VALR,DRSTBL,FRQRPR,UG1,AUG1,R1MAPR,R2MAPR, CASDSN,CASDSX,DRDUG,DRDUTB,CASADJ,LCDVECI,rr2idr, r3val,r3valr,resp3r,rmstbr,rmsvlr,FRLR,FOLR, UGM21, QGM21, QMPM21, UHM21,MODRPR,upsdt, RQATABR, RSP2XR,RSP3XR/ vols/vol/S,N,OBJVAL/S,N,NR1OFFST/S,N,NR2OFFST/ S,N,NCNOFFST/APP/ -1/SEID/DESITER/EIGNFREQ/ S,N,ADJFLG/PEXIST/MBCFLG/RGSENS/protyp/autoadjx/ fsdcyc/s,n,nr3offst/inrel/s,n,tadjc/PEID/s,n,ACTFREQ/ s,n,FREQ1/s,n,DLOADDS/FRQ345/DISCYC $ endalter $

Known Error

CR 1-16149704

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Distributed Memory Parallel (DMP - ASET - SFM 7467, SFM 6144 This is now fixed. (Remember don't test MDMODES on tiny job for now.)

Description

DMP does not support the use of ASET/ASET1 entries. If ASET/ASET1 is used, SYSTEM FATAL MESSAGE 7467 is issued correctly in version 2001. In version 2004, SFM 6144--the sizes of the input matrices and partitioning vectors are incompatible--is issued. Since ASET is not supported in DMP, this also implies that DMP does not support ADAMSMNF. Avoidance: For models using DMP, remove the ASET/ASET1 entries. ASET/ASET1 entires are supported in MDACMS and MDMODES and Freq Domain Modes in V2005. GDACMS and GDMODES are not supported.

Known Error

CR 1-16158821

Product

MSC / MD Nastran

Corrected Version GL Abstract

Heat Transfer Analysis - TEMPBC - Unreferenced TEMPB leads to wrong

Known Error

CR 1-16158821 answers.

Description

In nonlinear heat transfer analysis if input includes TEMPBC entries that are not referenced by DLOAD entries at the same degrees of freedom for which there are other TEMPBC entries that are referenced, then wrong answerws will result. Avoidance: Remove the unreferenced TEMPBC entries.

Known Error

CR 1-16163101

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Description

Elements - QUAD4, TEMP, MAT2, MAT8 - Poor Answers In MSC.Nastran a single precision transformation is performed for nonisotropic 2D materials (MAT2 and MAT8). This may lead to poor answers and is especially noticable when zero stresses are expected for a free expansion under thermal loads. Avoidance: Use the QUADR element.

Known Error

CR 1-16181301

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

Description

Elements - CRAC2D, CRAC3D, MAT8, MAT9 - UFM TA1 If the crac2d or crac3d elements reference mat8 or mat9 orthotropic/anisotropic materials the job will fatal in Version 2004.

Known Error

CR 1-16230501

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

Rotordynamics - ROTSEKE - Strain and kinetic energies are incorrect There are error in the ROTSEKE subDMAP that lead to

Description

1) Rotor numbers on output do not change 2) Energies are not calculated correctly.

Known Error

CR 1-16230501

Known Error

CR 1-16267101

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

Description

Optimization/Design Sensitivity - DRESP3 - Unexpected failure in DSTAp2 for DRESP3 optimization job An external response optimization job (DRESP3) may fail in DSTAP2 without an error message. Avoidance: There is no avoidance.

Known Error

CR 1-16270201

Product

MSC / MD Nastran

Corrected Version

2004.5

Abstract

Distributed Memory Parallel (DMP) - LAM/MPI error - IA64, SGI Altix, Itanium Distributed Memory Parallel (DMP) will not work with MSC.Nastran Versions 70.7-2004.0 on IA64 systems running RHEL 3.0 (Red Hat Enterprise). A message stating that the LAM Deamons will not boot will appear. The issues are related to RHEL 3.0 being based on glibc 2.3 which is incompatible with glibc 2.2 that versions of Nastran prior to Version 2004.5 were built with. Note that SGI Altix Propack Version 3.0 is also based on glibc 2.3. The special Version 70.7 Altix system requires the avoidance for serial jobs as well. However the special SGI Altix V2004.0.7 system is built with SGI's proprietary MPI libraries which support Propac 3.0. These special release are only available at: http://www.mscsoftware.com/support/software_updates/index.cfm

Description Avoidance: Use MSC.Nastran V2004.5 (a.k.a. MSC.Nastran 2004 R3) or Install an OS that uses GLIBC 2.2. or Download the updated drivers from: http://www.mscsoftware.com/support/software_updates/index.cfm#nastran that support glibc2.3 for Linux 64. On SGI Altix ia64 the following environmental varibles must also be set on all releases prior to 2005r2: setenv LD_ASSUME_KERNEL 2.4.19 setenv LD_PRELOAD /usr/lib/sgi-compat-preload.so

Known Error

CR 1-16270204

Product

MSC / MD Nastran

Corrected Version 2004.0.3 Abstract

Memory - Unable to Allocate - IA64/Linux

Description

V2004.0.0 IA64/Linux systems cannot allocate more than 2.0 Gb on the "mem" parameter. V2001.0.9 allowed memory allocation over 2Gb. This error was corrected in V2004.0.3.

Known Error

CR 1-16306501

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

Distributed Memory Parallel/ACMS - DMP - DISUTIL option 10 Bus Error

Description

DISUTIL option 10 may incur a Bus Error. This could affect distributed memory parallel ACMS, which is where DISUTIL option 10 is used most.

Known Error

CR 1-16320101

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Aerostatic Analysis - SPCFORCE, MPCFORCE, GPFORCE - SFM 5423 If GPFORCE, SPCFORCE, or MPCFORCE is specified in SOL 144 then the job may fail with SFM 5423. Avoidance: Specify PARAM,SPARSEDR,NO OR insert the following DMAP alter:

Description

compile fdrmgen alter 'IF ( not((AERO ','' IF ( noa>-1 ) then $ endalter

This is linked with 1-16241417 Known Error

CR 1-16323801

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

SOL 600 - MATEP - MATEP workhardening slope, H, is not translated to Marc, Wrong Answers

Description

In SOL 600 the MATEP workhardening slope, H, is ignored and is not translated

Known Error

CR 1-16323801 to Marc.

Known Error

CR 1-16323804

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

SOL 600 - CORDi - Loads applied in cylinderical coords are sometimes incorrect

Description

SOL 600 loads applied in cylinderical coordinates are sometimes incorrect. This can happen even if the loads are in the basic coordinate system but the grids have specified a cylindrical output coordinate system in field 7 of the GRID entry. In most cases, the loads are correct. Only in unusual circumstances are the loads incorrect.

Known Error

CR 1-16326601

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Optimization/Design Sensitivity - DESVAR - UFM 7105 When an optimization job specifies DESVAR IDs > 1 million and the DESVAR command is used to select part of DESVAR entries, the job may fail with the message:

Description

USER FATAL MESSAGE 7105 (DOPR3F) The Fiedl DVID aaaa on DVPREL1 Entry ID = yyyy is not selected by the DESVAR Case Control command. Avoidance: Specify DESVAR IDs < 1 million.

Known Error

CR 1-16332103

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

Static Analysis - PARAM,INREL,-2 - UFM 9050 In Version 2004, when param,inrel,-2, is specified to select inertia relief without the need to specify a SUPORT entry the analysis may fail with USER FATA MESSAGE 9050.

Description

Avoidance: Specify param,inrel,-1 and specify a suport entry. [JoeM] Recommed scaling of DRA (or DRG in the SELG PJ calc's), such that DRA(T)*MAA*DRA diagonal is in the KAA-diag avg range. High augmented KLL

Known Error

CR 1-16332103 factor-diag's should disappear.

Known Error

CR 1-16336101

Product

MSC / MD Nastran

Corrected Version 2005.5.2 Abstract

Eigenvalue Analysis - EIGRL - Extra Rigid Body Mode For one particular model, a slight variation of the mass matrix caused Lanczos to calculate an extra erroneous rigid body mode. The cause of the error is under investigation.

Description Avoidance: For this particular problem, perturbing the model's mass matrix and/or specifying F1 and F2 on the eigrl entry avoided the extra, erroneous rigid body mode. Known Error

CR 1-16420502

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

SOL 600 - Missing SPCs

Description

In SOL 600, an array in a is dimensioned 6 but values are set up to 8. This may cause Linux systems to fail to write SPCs resulting in an unconstrained model or wrong answers.

Known Error

CR 1-16442912

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

Matrix Methods - DCMP - Fails to issue UFM leading to wrong answers.

Description

Version 2004 uses Lagrange multipliers in static analysis and hence negative factor diagonals can now be common and the stiffness well conditioned. Thus, in Version 2004 DECOMP may ignore negative maxratio values and fail to issue a fatal message when it should.

Known Error

CR 1-16443309

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

External Superelements - EXTSEOUT, OUTPUT(PLOT), UFM 2025 (SDR2)

Description

If an external superelment, EXTSEOUT, superelement contains a displacement output request. and OUTPUT(PLOT) commands are used, the following

Known Error

CR 1-16443309 FATAL message will occur: *** USER FATAL MESSAGE 2025 (SDR2) UNDEFINED COORDINATE SYSTEM ID = 268435455 Avoidance: Removing the OUTPUT(PLOT) section will eliminate the error.

Known Error

CR 1-16455901

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Description

Optimization/Design Sensitivity - Eigenvector sensitivity with multiple boundary condtions broken Eigenvector sensitivity analysis based on DRESP1 entries was introduced in the 2004 release of MSC.Nastran. The original release supported multiple boundary conditions, but this capability was broken in the 2004.0.3 release (a.k.a 2004r2) when support for multiple boundary conditions in frequency response optimization was integrated. Avoidance: Use 2004.0.0 or version 2005.

Known Error

CR 1-16470701

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Description

Optimization/Design Sensitivity - Multiple Boudary Conditions not robust with multipl analysis types Mutiple boundary conditions with frequency response analysis was introduced into SOL 200 in Version 2004.0.3 (a.k.a. 2004R2). Testing has shown problems when there are multiple disciplines as well as multiple boundary conditions. In particular, runs with ANALYSIS = MODES and ANALYSIS= MFREQ with different boundary condition can produce fatal messages. Quality report 1-1655901 is related. Avoidance: The dmap changes required to support analysis =MFREQ and analysis=MODES and multiple boundary conditions are extensive so this capability is not considered to be operational. It will be operational in Version 2005.

Known Error

CR 1-16470704

Product

MSC / MD Nastran

Known Error

CR 1-16470704

Corrected Version 2005 Abstract

Description

Optimization/Design Sensitivity - Extra responses in formatted sensitivity prints Generalized mass and stiffness responses are "spawned" when the Rayleigh Quotient approach is applied to eigenvalue sensitivity analysis. These response are typically suppressed when formatted design senstivities are printed, but they appear if two different subcases share a DRES[1 id with type = eign or freq and the sensitivity is computed for both. In this case, the senstivities of the generalized matrices can appear following the eigenvalue sensitivities. Avoidance: An avoidance is to not share a DRESP1 ID for multiple subcases.

Known Error

CR 1-16474104

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

Nonlinear Buckling Analysis - DCMP - Missing UIM 4698 to identify instabilities To identify instabilities and isolate buckling, the user should look for UWM 4698. However, in Version 2004 DCMP does not print the message making it impossible to identify buckling phenomena. The following is an example of the missing message:

Description

*** USER WARNING MESSAGE 4698 (DCMPD) STATISTICS FOR DECOMPOSITION OF MATRIX K(appropriate) . THE FOLLOWING DEGREES OF FREEDOM HAVE FACTOR DIAGONAL RATIOS GREATER THAN 1.00000E+07 OR HAVE NEGATIVE TERMS ON THE FACTOR DIAGONAL. GRID POINT ID DEGREE OF FREEDOM MATRIX/FACTOR DIAGONAL RATIO MATRIX DIAGONAL 102 R2 -1.93940E+03 2.14680E+04 Verified this message has been restored. Tested in V2004.5 and V2005.0.0. lproctor 12/6/04, sorry for delay didn't know it was assigned to me, I guess this can be closed.

Known Error

CR 1-16479901

Product

MSC / MD Nastran

Known Error

CR 1-16479901

Corrected Version 2008.0.0 (MD R3) Abstract

MDACMS fails for all fluid model - SFM 3001 If ACMS is attempted on a model with only fluid elements and no structural elements then the run will fail with: *** SYSTEM FATAL MESSAGE 3001 (MDENZO) THE INPUT DATA BLOCK NAMED MKXX AT POSITION 1 DOES NOT EXIST.

Description

Avoidance: compile modefsrs alter 'mdacms=', '' $ paraml vafs//'null'//s,n,full $ mdacms=(NDOM>0 and full=0) $ all fluid models not allowed endalter

Known Error

CR 1-16498001

Product

MSC / MD Nastran

Corrected Version 2005.5 Abstract

External Superelements - UFM 6802 It has been observed on an external superelement run that the job failed in finding the boundary points with the following messages:

Description

UFM 6802 - SE 0 has failed to automaticaly derive a search key - user action to review model or override search key. Avoidance: Run the reduction run with the DMIGPCH option and include the DMIG entries without using the .asm file.

Known Error

CR 1-16500402

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

Superelements - Print Format error in TABPRT

Description

The Superelement Summary Output in the f06 filem may contain asterisks for large integer grid id's (******).

Known Error

CR 1-16503108

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Acoustics - FLSPOUT, STRUCTMP - Mislabeled Ouput

Description

Modal participation factors are calculated for each subcase but are

Known Error

CR 1-16503108 mislabled as the first subcase.

Known Error

CR 1-16548801

Product

MSC / MD Nastran

Corrected Version 2005.1 Abstract

Heat Transfer - large view factor computation - SFM 3008 (RMG2) Heat transfer jobs with large view computations may fail with the message: *** SYSTEM FATAL MESSAGE 3008 (RMG2) INSUFFICIENT MEMORY AVAILABLE FOR SUBROUTINE RMG2 0FATAL ERROR

Description

Avoidance: increasing memory may avoid this error. If using SOL 400, there is new design using the reflection method which move the decomposition to teh right hand side thus reducing the requirement of using the physical memory. This is activated in SOL 400 using: nlmopts,hemi,,,,,,1 put a 1 on the field 8 on the NLMOPTS will activate the reflection method.

Known Error

CR 1-16567604

Product

MSC / MD Nastran

Corrected Version 2005.5 Abstract

Rigid Elements - RIGID=LAGRANGE, GPFORCE - SFM 3007 GPFDR

Description

RIGID=LAGRANGE may cause jobs to fail in the GPFDR module with SYSTEM FATAL MESSAGE 3007.

Known Error

CR 1-16603701

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

DMAP - NOT, AND, OR - SFM 223 poor diagnostic If the name of an expression like NOT or AND is used as a variable name, it is accepted in some statements but causes a message that is difficult to understand when it appears.

Description

An error report is attached to the back of the test problem, along with some suggested fixes. mag

Known Error

CR 1-16606402

Product

MSC / MD Nastran

Corrected 2005 Version Abstract

SSSALTER - spc101a alter missing In Nastran 2004 the spc101a alter was not included.

Descriptio Avoidance: SSSALTERs are posted to the web at: n http://www.mscsoftware.com/support/prod_support/nastran/sssalters/v2004/toc. cfm Known Error

CR 1-16630701

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Optimization - DRESP1 - Transient response types on the DRESP1 do not support multiple components. Rermark 7 for the DRESP1 entry in the QRG indicates that TDISP, TVELO, TACCL and TSPCF support multiple components. A code bug blocks this to a single component less than or equal to 6.

Description

Also for GPFORCP. the ATTA input is a grid id. therefore there are documentation errors in table 8-9 on the DRESP1 entry in the QRG and in Remark 7, GPFORCP should be omitted. Avoidance: Single components can be used for the transient responses with no loss of functionality. Mutiple components only simplify the input.

Known Error

CR 1-16634301

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Eigenvalue Analysis - RESTART, SOL 106, multiple subcases, stress stiffened normal modes If a normal modes (SOL 103) analysis is restarted from a nonlinear static solution (SOL 106) which contained more than one subcase, the eigenvalues calculated may be incorrect.

Description Avoidance: Insert the following DMAP alter in the SOL 103 restart run

Known Error

CR 1-16634301 ECHOOFF $ COMPILE SEMG LIST $ ALTER 'PARAML.*CASESR','' $ PARAML CASESR//'DTI'/recno/4//S,N,LOADID $ ENDALTER $ ECHOON $

Known Error

CR 1-16658001

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Postprocessing - MCFRACTION - No output written to op2 file

Description

No MCFRACTION results are written to the op2 file.

Known Error

CR 1-16663924

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Differential Stiffness - CBAR - Missing UWM 6174 leads to wrong answers Solutions that use differential stiffness (105, 106 and any SOL with STATSUB) that have CBEAM elements with offsets will correctly issue the message below. However; this message may not be issued for similar models with CBAR elements.

Description

*** USER WARNING MESSAGE 6174 (EBEMD) BEAM ELEMENT (EID=110) WITH OFFSETS ARE NOT SUPPORTED IN DIFFERENTIAL STIFFNESS OR NONLINEAR ANALYSIS. REMODEL WITHOUT USING BEAMS WITH OFFSET. 0FATAL ERROR

Known Error

CR 1-16663960

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Documenation/QRG - CQUAD4/CTRIA3 enhancements for differential stiffness The following paragraph under remark 3 of the CTRIA3 description and remark 6 under the CQUAD4 description is no longer true and should be removed:

Description

The differential stiffness for the offset vectors is not computed. Therefore, solution sequences (SOLs 105 and 200; SOLs 103 and 107 through 112 with STATSUB) that require differential stiffness to get correct result, give wrong results. However, for the nonlinear solution sequences (SOLs 106,

Known Error

CR 1-16663960 129, and 400), the differential stiffness is not required to give correct results, therefore, the results are correct, if the solution converges.

Known Error

CR 1-16700702

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Postprocessing - POST - Missing Output in op2 file

Description

If POST NODISP is specified in one subcase then results may be missing from the op2 files in subsequent subcases.

Known Error

CR 1-16723804

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Description

Frequency Response - MEFFMASS - signal 8 MEFFMASS command may lead to the following error on Nastran 2004 HPUX systems: ---------SIGNAL CAUGHT: Signal number = 8 Signal code = 14 Signal tid = 1 Fault addr = 4000000001352823 FP inexact = 0x0 FP divide0 = 0x8000 FP underflow = 0x0 FP overflow = 0x10000 FP invalid = 0x0 Avoidance: Either remove the MEFFMASS command or run on another machine.

Known Error

CR 1-16761101

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Description

Superelments - EXTSEOUT - Double Field Grids result in SFM 3002 in the BDRYINFO module. External superelements, EXTSEOUT, may fail with SYSTEM FATAL MESSAGE 3200 (LOGIC ERROR 28) in the BDRYINFO module if double field GRID entries are used.

Known Error

CR 1-16761101 Avoidance: Use single field GRID entries or double field GRID entries with the grid IDs in columns 9-16

Known Error

CR 1-16769901

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Documentation - V2004 DMAP Programmers Guide - UMERGE1 The Version 2004 DMAP programmers guide shows the following for the format of the UMERGE1 module:

Description

UMERGE1 USET,A11,A21,A12,A22/MAJOR/SET1/SET2/IOPT $ It should be: UMERGE1 USET,A11,A21,A12,A22/A/MAJOR/SET1/SET2/IOPT $

Known Error

CR 1-16771901

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Composites - PCOMPG - Strength Ratio may cause composite stress & failure index output error

Description

When PCOMPG bulk data entries are used (with a blank FT field) and Strength Ratio output request is turned on (PARAM,SRCOMPS,YES), the composites stress, failure index and strength ratio output may be either missing or incorrect.

Known Error

CR 1-16796101

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Error in DRMH1 - because of round-off there was a format mismatch. Error corrected. If the DRMH1 module is used to create a stress table and a PSHELL entry exists with a thickness of exactly 0.02, the table created will cause an error in the DRMH3 module when the OFP table is reassembled.

Description Avoidance: Use a slightly smaller or large value on the PSHELL entry, e.g. 0.0200001 will allow the module to run correctly. Known Error

CR 1-16815502

Known Error

CR 1-16815502

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Composites - PCOMP - Nastran fails with signal 11 if duplicate IDs for MAT entries exist

Description

If a PCOMP entry references a MAT8 entry that has the same ID as another MAT entry, i.e. MAT1, Nastran fails with signal 11 in the log file. No other error messages are given.

Known Error

CR 1-16821701

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

Installation - HPUX 11 - ERROR: Unable to update RC file MSC.Nastran Version 2004.5 may have trouble installing on older versions of ksh on HPUX 11. If the following messages are encountered during installation then upgrade the ksh to at least 82.10.1.48 which was released in 2002. The error is considered fixed by this upgrade. Begin configuring MSC.Nastran 2004.5 Creating default version links... Configuring licensing... makercentry[4]: /tmp/./msc/conf/nast20045rc: cannot create

Description

ERROR: Unable to update RC file "/tmp/./msc/conf/nast20045rc" Setting user configuration items... makercentry[4]: /tmp/./msc/conf/nast20045rc: cannot create ERROR: Unable to update RC file "/tmp/./msc/conf/nast20045rc" makercentry[4]: /tmp/./msc/conf/nast20045rc: cannot create ERROR: Unable to update RC file "/tmp/./msc/conf/nast20045rc"

Known Error

CR 1-16855001

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Nonlinear Analysis - STRESS(PUNCH) - Bad Output in PUNCH File

Description

In SOL 106, nonlinear analysis, a request for nolinear stresses to be output to the punch file, STRESS(PUNCH), will lead to NanQ or ????? in the punch file.

Known Error

CR 1-16857203

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Transient Analyis - SOL 112, SE, No Physical Residual, BIOMSG 1044, UFM 4276 QOPEN If CMS is performed on Superelement, and enforced motion is performed on Residual with ALL physical dof constrained, then TRD1 will fail with

Description

*** USER INFORMATION MESSAGE 5222 (TRD1) UN COUPLED SOLUTION ALGORITHM USED. BIOMSG: ERROR 1044 HAS OCCURRED IN ROUTINE QOPEN , FILE INDEX = 0. STATUS = 0 ... *** SYSTEM FATAL MESSAGE 4276 (QOPEN) ERROR CODE 1044 PID= 0 *** USER INFORMATION MESSAGE 4276 (QOPEN) Avoidance: Apply the following alter: malter 'paraml.*icspcd.*icspcdx' ICSPCDX=0 $

Known Error

CR 1-16858013

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Documentation - V2004 DMAP Programmers Guide - MTRXIN description for NOMATi The Version 2004 DMAP Programmer's Guide MTRXIN description for the NOMATi flags indicates that the flags are set to a value of +1 whether the matrix is present or not. The description indicates:

Description

NOMATi Output-integer-default=1. Generation flag. Set to +1 if MAT* is generated; 1 otherwise. this should read: NOMATi Output-integer-default=1. Generation flag. Set to +1 if MAT* is generated; -1 otherwise.

Known Error

CR 1-16877703

Product

MSC / MD Nastran

Known Error

CR 1-16877703

Corrected Version 2005 Abstract

Miscellaneous - Disk full on Windows 2000 leads Access Violation A "DISK FULL" condition may lead to an access violation on Windows 2000.

Description

Avoidance: This error can be avoided by specifying "sysfield=mapio=no" in a .rcf file or on the command line when the MSC.Nastran job is submitted. *************************** Requested client to run with sysfield=mapio=no on command line. These jobs have not failed since sysfield=mapio=no.

Known Error

CR 1-16888416

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Description

Installation - Installation Errors on AIX 5.2 - mscinfo[281]: ram+= : syntax error A "full" installation of MSC.Nastran 2004r2 on for AIX 5.2. fails with the following message while the installation is unloading the install script: mscinfo[281]: ram+= : syntax error

Known Error

CR 1-16901604

Product

MSC / MD Nastran

Corrected Version GL Abstract

Elements - CBUSH, PBUSHT, MPC - Wrong Answers

Description

If forces converge to unexpected results in nonlinear-it is recommended that the convergence tolerences be tightened to see if better convergence can be obtained.

Known Error

CR 1-16903301

Product

MSC / MD Nastran

Corrected Version Abstract

DMAP - DECOMP - DET method yields incorrect results for complex matrices

Description

The DET function of DEC0MP yields incorrect results for complex matrices. The scaled determinant is correct but the power term is returned as zero.

Known Error

CR 1-16903901

Product

MSC / MD Nastran

Corrected Version 2005

Known Error

CR 1-16903901

Abstract

External Superelements - EXTSEOUT - Missing Output An assembly run employing an external superelement created using the EXTSEOUT feature does not give any output for the external SE if the creation run has no DISP request. Avoidance: Apply the following dmap alter to the assembly run:

Description compile extotmin alter 'dbstatus x_tug,x_rga',''(,1) $ dbstatus x_tug,x_tef,x_tes,x_tqg,x_rga// s,n,notug/s,n,notef/s,n,notes/s,n,notqg/s,n,norga $ if ( notug>0 or notef>0 or notes>0 or notqg>0 or norga>0 ) then $ endalter $ Known Error

CR 1-16917801

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Description

Optimization/Design Sensitivity - Multiple Boundary Conditions, Output labelled incorrectly. For SOL 200 with ANALYSIS=MFREQ and multiple boundary conditions, BC=, the output for 2nd subcase onwards are labelled incorrectly. Avoidance: Request DMAP alter from client support.

Known Error

CR 1-16917806

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Optimization/Design Sensitivity - DRESP2, DRESP1 - UFM 3007 (dopr3)

Description

SOL 200 jobs may fail if DRESP2 entries that reference DRESP2 entires coexist with DRESP2 entries that reference DRESP1 entries.

Known Error

CR 1-16924801

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Miscellaneous - Include may not working on Windows 2000 if file attributes are chaned from default

Description

On Windows 2000, if a nastran include data file has the attributes (properties, Advanced, uncheck the "file is ready for archiving" and uncheck the "For

Known Error

CR 1-16924801 fast searching") Then the job aborts.

Known Error

CR 1-16936701

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

SOL 700 - SOL 700 in Natran 2004r3 (2004.5) does not work on Windows systems

Description

SOL 700 for Natran 2004r3 (2004.5) does not work on Windows systems because the latest Intel compilers provide full path names for the dytran-lsdyna input file and dytran-lsdyna is not able to accept full path names.

Known Error

CR 1-16937701

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Description

Case Control - ESE THRESH does not work when there is no SUBCASE command The THRESH option of the ESE Case Control command does not work if a SUBCASE command is not present. Avoidance: Add a SUBCASE command.

Known Error

CR 1-16938101

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

SOL 600 - PCOMP - Wrong Answers when Z0 is specified When translating the Nastran PCOMP enty into a Marc deck, if the Z0 field is specified, then the resulting Marc COMPOSITE entry will be wrong.

Description

The current action is to take whatever value is in the PCOMP Z0 field and map it directly into the Marc's COMPOSITE 3rd datablock 4th field. The 'meaning' of the Z0 on the PCOMP entry and this field in Marc are incompatible. In NASTRAN, Z0 on a PCOMP entry defines the distance from the reference plane to the bottom surface of the laminate. In Marc, the field it is mapped to represents the position of the user-defined reference plane. This is the value of the local z-coordinate of the user-defined plane with respect to the geometric midplane.

Known Error

CR 1-16959902

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Superelements - SEEEXCLD - UFM 6788 (SEPMFS) A model that has duplicate boundary grids in the residual structure may fail to exclude the duplicate grid and may fail with the message:

Description

*** USER FATAL MESSAGE 6788 (SEPMSF) SUPERELEMENT 1 GRID 3 AND SUPERELEMENT 0 GRID 13 HAVE CONFLICTING MANUAL DIRECTIVES.

Known Error

CR 1-16969464

Product

MSC / MD Nastran

Corrected Version GL Abstract

Miscellaneous - SYSTEM(55)=0 - UFM 315 (IFPDRV) If SYSTEM(55) is set to 0, Nastran will likely fail in ifpdrv with the message:

Description

*** USER FATAL MESSAGE 315 (IFPDRV) FORMAT ERROR ON BULK DATA ENTRY GRID SYSTEM(55), a.k.a. IPREC, only expects a value of 1 for single precision or two for double precision. The user is never expected to set this system cell.

Known Error

CR 1-16978601

Product

MSC / MD Nastran

Corrected Version Abstract

Frequency Response - Enforced Motion, SPCD - UWM 2108, UFM 3046, SFM 3003, SFM 5423 If multiple boundary conditions are specified with enforced motion in dynamic analysis then the following errors may occur: V2004r1 and V2004r2 : UWM2108,UFM3046 V2004r3 and V2005 : UWM2108,SFM3003 or SFM 5423

Description

Avoidance: Insert the following DMAP alter: compile phase0 alter 'if ( appc='(2),'' type parm,,char8,n,blank $ IF ( APP='FREQRESP' ) THEN alter 'LCGEN.*CASE1X','' LCGEN CASE1X,SLT,ETT,DYNAMIC0,GEOM4S/CASE1//APP $

Known Error

CR 1-16978601 alter 'if ( seid=0 and (app='(2),'' if ( false ) then $ alter 'if ( appc='(3),'' IF ( APP='FREQRESP' ) THEN alter 'gp4.*caseq' paraml casew//'dti'/nskip/1//s,n,subcid $ call dbstore yg1,,,,//subcid/0/blank/0 $ compile phase1dr alter 'call phase1b'(,-1) paraml casew//'dti'/nskip/1//s,n,subcid $ call dbfetch /yg1,,,,/subcid/0/0/0/0 $ equivx yg1/yg/-1 $ compile semfreq alter 'nzyg0',''(,1) alter ' dpd '(,-1) paraml casem//'dti'/1/1//s,n,subcid $ call dbfetch /yg1,,,,/subcid/0/0/0/0 $ equivx yg1/yg/-1 $ matmod yg,,,,,/nzyg0,/6 $ diagonal nzyg0/nzyg/'whole'/0. $ ones at non-null YS rows compile sedfreq alter 'nzyg0',''(,1) alter ' dpd '(,-1) paraml casem//'dti'/1/1//s,n,subcid $ call dbfetch /yg1,,,,/subcid/0/0/0/0 $ equivx yg1/yg/-1 $ matmod yg,,,,,/nzyg0,/6 $ diagonal nzyg0/nzyg/'whole'/0. $ ones at non-null YS rows endalter

Known Error

CR 1-16989601

Product

MSC / MD Nastran

Corrected Version 2004.0.7 Abstract

Miscellaneous - IA32 Linux - Include files > 2Gb - UFM 398

Description

Input files greater than 2Gb may not be included in a data file in Versions 2004.0.6 and prior on IA32 Linux systems. Version 2004.0.7 and later systems allow include files greater than 2Gb. Avoidance: If you must use version 2004.0.6 or earlier, then break the include file into separate files each less than 2Gb

Known Error

CR 1-17005701

Known Error

CR 1-17005701

Product

MSC / MD Nastran

Corrected Version 2005.1 Abstract

External Superelements - EXTSEOUT , SOL 101 - Wrong Answers EXTSEOUT usage in SOL 101 gives wrong results for the external SEs in the assembly run if the external SE has loads applied to its interior points. In other words, the fixed-boundary o-set displacements are not included in the external SE data recovery. Avoidance: Use the following DMAP alters in the external SE creation runs as well as in the assembly run.

Description

compile super3 alter 'call extotmin'(,-2),''(,0) file tug1=ovrwrt/tes1=ovrwrt/tef1=ovrwrt/tqg1=ovrwrt $ call dbfetch /dtis,dtindxs,dmis,dmindxs,/seid/0/0/0/0 $ dtiin dtis,dtindxs/ tug1,tes1,tef1,tqg1,,,,,,/ s,n,notug/s,n,notes/s,n,notef/s,n,notqg $ exterse=(exterse or notug or notes or notef or notqg) $ if ( exterse ) then $ call extotmin maps,dmis,dmindxs,uset,eqexins, xsop2dir,matpools/ tug1,mug1,tqg1,mqg1,tes1,mes1,tef1,mef1, rga,ugo,mug1o,mqg1o,mes1o,mef1o/ statics $ call dbstore mug1o,mqg1o,mes1o,mef1o,//seid/0/' '/0 $ compile phase0 alter 'call ifps' call dbstore dmindxs,dtindxs,dmis,dtis,//seid/0/' '/0 $ compile sedrcvr alter 'MPYAD.*mug1,uls1,','' call dbfetch /mug1o,mqg1o,mes1o,mef1o,/seid/0/0/0/0 $ if ( notug1>0 ) MPYAD mug1,uls1,mug1o/iugx $ alter 'MPYAD.*mef1,uls1','' MPYAD mef1,uls1,mef1o/iefx $ alter 'MPYAD.*mes1,uls1','' MPYAD mes1,uls1,mes1o/iesx $ alter 'MPYAD.*mqg1,uls1','' MPYAD mqg1,uls1,mqg1o/iqgx $ compile extotmin alter 1,1 subdmap extotmin maps,dmis,dmindxs,uset,eqexins, xsop2dir,matpools/

Known Error

CR 1-17005701 tug1,mug1,tqg1,mqg1,tes1,mes1,tef1,mef1,rga,ugo, mug1o,mqg1o,mes1o,mef1o/ statics $ alter 'dbview' dbview x_mugo=extdb where (seid=temp and xname='mug1o' and wildcard) dbview x_meso=extdb where (seid=temp and xname='mes1o' and wildcard) dbview x_mefo=extdb where (seid=temp and xname='mef1o' and wildcard) dbview x_mqgo=extdb where (seid=temp and xname='mqg1o' and wildcard) alter 'if ( xname=','' if ( xname='matrga' or xname='tug1' or xname='mug1' or xname='tes1' or xname='mes1' or xname='tef1' or xname='mef1' or xname='tqg1' or xname='mqg1' or xname='mug1o' or xname='mes1o' or xname='mef1o' or xname='mqg1o' ) then $ alter 'equivx.*x\_tqg',''(,3) if ( statics ) then $ equivx x_mugo/mug1o/-1 $ equivx x_meso/mes1o/-1 $ equivx x_mefo/mef1o/-1 $ equivx x_mqgo/mqg1o/-1 $ endif $ statics else $ dmiin dmis,dmindxs/mug1,mes1,mef1,mqg1,,,,,, $ if ( statics ) dmiin dmis,dmindxs/mug1o,mes1o,mef1o,mqg1o,,,,,, $ matmod tug1,,,,,/tug1x,/32/1 $ equivx tug1x/tug1/-1 $ matmod tef1,,,,,/tef1x,/32/1 $ equivx tef1x/tef1/-1 $ matmod tes1,,,,,/tes1x,/32/1 $ equivx tes1x/tes1/-1 $ matmod tqg1,,,,,/tqg1x,/32/1 $ equivx tqg1x/tqg1/-1 $ mtrxin ,,matpools,eqexins,,/vax,,,,/lusets $ merge ,,,mug1,,vax,/mug1x/1 $ equivx mug1x/mug1/-1 $ merge ,,,mef1,,vax,/mef1x/1 $ equivx mef1x/mef1/-1 $ merge ,,,mes1,,vax,/mes1x/1 $ equivx mes1x/mes1/-1 $ merge ,,,mqg1,,vax,/mqg1x/1 $ equivx mqg1x/mqg1/-1 $ compile extout alter 'SDR2.*CASEs'

Known Error

CR 1-17005701 dbstatus uoo//s,n,nouoo $ if ( nouoo>0 ) then $ umerge uset,uoo,/ugo/'g'/'o' $ dbstatus v01s//s,n,nov01s $ if ( nov01s>0 ) then $ Partn ugo,,v01s/,ugo1,,/0 $ delete /ugo,,,, $ merge ,,ugo1,,,,v01s/ugo/0 $ endif $ nov01s>0 SDR2 CASEs,CSTMS,MPTS,DIT,EQEXINS,,ETT,nulllama,BGPDTS,,qg, ugo,EST,XYCDBs,,,,,,,,,,,,,,/ ,iqg1o,IUG1o,IES1o,IEF1o,,,,,,,/ 'reig'/S,N,NOS2A/S,N,NCOMPS $ DRMH1 Iug1o,Iqg1o,Ies1o,Ief1o/ TUG1o,MUG1xo,TQG1o,MQG1xo,TES1o,MES1xo,TEF1o,MEF1xo/ /1/7/3/1005/1004 $ add5 mug1xo,,,,/mug1o $ add5 mqg1xo,,,,/mqg1o $ add5 mes1xo,,,,/mes1o $ add5 mef1xo,,,,/mef1o $ endif $ nouoo>0 alter 'EQUIVX mug1\/EXTDB' xname = 'mug1o' $ EQUIVX mug1o/EXTDB/-1 $ alter '15.*\'mug1' append ,,/xsop2dir/15///////'mug1o' $ alter 'EQUIVX mqg1\/EXTDB' xname = 'mqg1o' $ equivx mqg1o/extdb/-1 $ alter '15.*\'mqg1' append ,,/xsop2dir/15///////'mqg1o' $ alter 'EQUIVX mes1\/EXTDB' xname = 'mes1o' $ equivx mes1o/extdb/-1 $ alter '15.*\'mes1' append ,,/xsop2dir/15///////'mes1o' $ alter 'EQUIVX mef1\/EXTDB' xname = 'mef1o' $ equivx mef1o/extdb/-1 $ alter '15.*\'mef1' append ,,/xsop2dir/15///////'mef1o' $ alter 'matpch mug1' matpch mug1o,mqg1o,mes1o,mef1o/ $ alter 'xname=\'mug1\''(,2) xname='mug1o' $ dbstatus extdb//s,n,noextdb $ if ( noextdb>0 ) output2 extdb//0/outunit///'matrix' $

Known Error

CR 1-17005701 alter 'xname=\'mqg1\''(,2) xname='mqg1o' $ dbstatus extdb//s,n,noextdb $ if ( noextdb>0 ) output2 extdb//0/outunit///'matrix' $ alter 'xname=\'mes1\''(,2) xname='mes1o' $ dbstatus extdb//s,n,noextdb $ if ( noextdb>0 ) output2 extdb//0/outunit///'matrix' $ alter 'xname=\'mef1\''(,2) xname='mef1o' $ dbstatus extdb//s,n,noextdb $ if ( noextdb>0 ) output2 extdb//0/outunit///'matrix' $ endalter

Known Error

CR 1-17011701

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Description

Optimization/Design Sensitivity - DRESP2 - Illegal Input to dopr3j When a DRESP2 response in a SOL 200 job intends to reference an existing DRESP1 entry but precedes with a DRESP2 flag, the job fails in DOPR3 with the fatal message "illegal input to subroutine DOPR3J". Avoidance: Specify the correct DRESP1 flag for the referenced entries.

Known Error

CR 1-17013601

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

ADAMS/Flex - MNF grid point stress null for quadratic shell mid-side nodes

Description

The ADAMS/Flex modal neutral file's modal grid point stress/strain results are null for mid-side nodes of quadratic shell elements due to the fact that nastran does not compute grid point stress results for mid-side nodes of quad8 and tria6 elements. The ADAMS/Flex element face information for elements of these types should contain only the corner grid data and not the mid-side nodes.

Known Error

CR 1-17025310

Product

MSC / MD Nastran

Corrected Version 2005.1 Abstract

Installation - mscsetup - Linux install fails; cannot determine disk space

Description

Nastran 2004 "mscsetup" script fails on Mandrake Linux 9.1/ 10.0 because it cannot determine the amount of free disk space.

Known Error

CR 1-17025310 Suggestions: "mscsetup" uses "df -k" to determine disk space. However, if "df -k" outputs multiple lines, the "awk" procedure cannot determine the actual disk space. Avoidance: Replace the following line in mscsetup linux* ) set -- $(df -k $dir 2>/dev/null | awk 'NR==2{printf("%d %d\n",$4/1024,$2/1024)}') with: linux* ) set -- $(df -k $dir | awk 'NR==2 && NF>1{printf("%d %d\n",$4/1024,$2/1024);exit} NR==3{printf("%d %d\n",$3/1024,$1/1024);exit}')

Known Error

CR 1-17055508

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Superelements - PARAM,METHCMRS - UFM 3032 In solution 103 if param,methcmrs references an EIGR set id, the job may fail with the message: *** USER FATAL MESSAGE 3032 (READ) UNABLE TO FIND SELECTED SET ( 2000) IN TABLE (EED ) IN SUBROUTINE (REIG).

Description Avoidance: Insert the following DMAP alter: compile phase0 alter 'SEP2.*nGEOM1,GEOM2,GEOM3,GEOM4'(2) if ( seid=0 ) equivx dynamic/dynamics/-1 $ endalter Known Error

CR 1-17064430

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Distributed Memory Parallal - User must specify F2 on EIGR entry

Known Error

Description

CR 1-17064430 If a dmp job only specifies ND on the EIGR entry using method LAN and the DOMAINSOLVER entry specifies the partopt=freq option the job may attempt to solve all frequencies on all processors. Avoidance: The user must select F2 on the eigr entry.

Known Error

CR 1-17071801

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Miscellaneous - INPUTT2 - OP2 files with matrices and tables may lead to UFM in INPUTT2

Description

OP2 files with intermixed tables and matrices that were correctly read in MSC.Nastran V2004.0.6 fail in V2004.5. The problem is caused because code handling end of matrix condition did not properly accept all valid conditions.

Known Error

CR 1-17081504

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Submittal - node=machine does not work on NT

Description

The node=machine nastran submit line option cannot be used from NT to a dissimilar machine.

Known Error

CR 1-17101614

Product

MSC / MD Nastran

Corrected Version 2005.5 Abstract

Documentation/QRG - PARAM,ERROR - Incorrect Default Value

Description

The default value of "0" for the parameter ERROR as shown in the QRG is incorrect. The correct default value is -1

Known Error

CR 1-17101627

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Frequency Response - ESE, OFREQ - OFREQ ignored If there are multiple subcases with different OFREQ callouts, the OFREQ command is ignored for ESE output.

Description

Avoidance: Either don't use OFREQ or only use one subcase when ESE output is desired

Known Error

CR 1-17104601

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

SOL 600, SOL 700 - Windows Version 2004.5 not useable

Description

The switch to Intel Version 8 compiler in MSC.Nastran Version 2004.5 for Windows caused many problems in SOL 600 and SOL 700. Thus, this release should not be used for SOL 600 and 700 on Windows.

Known Error

CR 1-17148302

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Optimization/Design Sensitivity - DOPR1, PCOMP - Poor Message, Illegal input to DOPR1I A composite optimization job fails in DOPR1 with "Illegal Input to Subroutine DOPR1I" if the following two conditions are met: 1. The integer input with FID option is used to sepcify a designed laminate thickness or ply angle on a DVPREL1/2 entry and 2. The laminate thickness or ply angle that the FID represents is Not defined on a PCOMP entry.

Description For example, only two laminates are defined on a PCOMP entry but the FID field on a DVPREL1 entry references the thickness for the third laminate.

Avoidance: Only design the laminate thickness or ply angle on a DVPRELi entry that is defined on a PCOMP entry. Known Error

CR 1-17172902

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Description

Installation - Nastran 2004r3 nast20045.rcf file not created. The rcf file for Version 2004.5 (2004r3) on for Windows is created as a file named "nast2004.rcf" which is ignored. Avoidance: The program will recognize the rc file if it is renamed to "nast20045.rcf".

Known Error

CR 1-17172908

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Installation - Path to License server is ignored

Description

During installation on Windows, the user is asked to enter authorization

Known Error

CR 1-17172908 information. Inputting a valid "port@host" entry is ignored and the default "authoirz.dat" is entered into the rc file for the AUTH= keyword. Avoidance: The user must manually edit to rc file.

Known Error

CR 1-17177340

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Aeroelastic Analysis - Direct Enforced Motion, wrong results

Description

Solution 146 produces wrong results showing when direct enforced motion is used. The call to subDMAP SUPER3 with AULF is missing data block RGY (penultimate input data block). This may cause some grids to deflect incorrectly.

Avoidance: PARAM,DDRMM,-1 will also avoid the data recovery error. Known Error

CR 1-17194201

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Description

ESE - UWM 4506, UIM 4507, subcase, TOTAL ENERGY OF ALL ELEMENTS IN PROBLEM = 0.0 If a job incorrectly specifies SUBCASE1 with no space instead of SUBCASE 1, the subcase number is read as zero. If ESE output is requested, UWM 4506 and UIM 4507 may be issued indicating the total strain energy is zero. No warning message is given that the SUBCASE entry is in error. The ESE output shows TOTAL ENERGY OF ALL ELEMENTS IN PROBLEM = 0.000000E+00 and no list of strain energies by element is output Avoidance: Correct the SUBCASE entry to leave a space between the word SUBCASE and the 1

Known Error

CR 1-17202601

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Acoustics - DAREA entries not converted to static loads if they reference fluid points

Description

Currently, DAREA entries are not converted into equivalent static load entries if they reference fluid grid points.

Known Error

CR 1-17203001

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Distributed Memory Parallel - MDACMS with ESE fails if PARAM,POST specified

Description

Parallel MDACMS with ESE request and PARAM,POST will fail since slave processes are not prevented from attempting to write to the output2 file. Solution is to modify the DMAP to call OUTPUT2 only on the master. (Alter can be generated on request.)

Known Error

CR 1-17210346

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Post Processing - PARAM,POST,-2 - Lama table not output2 with post,-2 The llama table is not output2 to the op2 file with param,post,-2.

Description Avoidance: Use param,postext,yes. Known Error

CR 1-17234402

Product

MSC / MD Nastran

Corrected Version 2005.1 Abstract

Postprocessing - UFM 1004 (CLSPFL) for huge output2 Postprocssing that creates extremely large op2 files may fail with the message: *** USER FATAL MESSAGE 1004 (CLSPFL) FORTRAN UNIT CLOSE ERROR.

Description USER INFORMATION: IOSTAT = 180, Invalid argument (errno=22) LOGICAL = OUTPUT2 FILE = ./topo_02_015.op2 Known Error

CR 1-17242803

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Post Processing - Incomplete XDB File

Description

The DBC/XDB object in the dictionary does not contain the correct control information, it contains the original object template when the create function completes. This may lead to an incomplete xdb file which may cause post

Known Error

CR 1-17242803 processers to fail. This error has only been observed for one test file that contained 55 subcases. Avoidance: A possible avoidance is to change the block size of the xdb in the FMS section.

Known Error

CR 1-17252901

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

External Superelements - UFM 1126, Datablock GOA already exists In Version 2004.5 an external superelement reduction run with ACMS results in the following fatal message: *** USER FATAL MESSAGE 1126 (GNFIST) DMAP MODULE UMERGE1 IS ATTEMPTING TO OUTPUT DATABLOCK 201 NAME = GOA , WHICH ALREADY EXISTS.

Description Avoidance: Insert following DMAP alter: compile phase1b alter 'call segoa'(9,-1) delete /goa,,,, $ endalter Known Error

CR 1-17256104

Product

MSC / MD Nastran

Corrected Version 2005.5 Abstract

Documentation/QRG - MEFFMASS - Incorrect description of wtmass

Description

The MSC.Nastran Quick Reference Guide incorrectly indicates the Modal Effective Weight is the Modal Effective Mass multipled by the parameter WTMASS. This is incorrect, it is divided by WTMASS.

Known Error

CR 1-17278455

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Description

Aeroelastic Analysis - OLOAD - Request Fails in SOL 146 The OLOAD output request for SOL 146 is not being honored when only frequency response analysis is performed. Avoidance: Apply the folloiwng alter which changes the fifth input datablock in the final super3 call from ppf1 to pgf1

Known Error

CR 1-17278455 compile seaero alter 'super3'(3),'' CALL SUPER3 CASECC , ,AULF ,FOL1 ,PgF1 , PSF1 ,frl ,LAMA ,AUHF1 ,DLT , ,,,,, ,PCDB ,XYCDB ,POSTCDB , , EMAP ,MAPS ,EQEXINS ,PVTS ,CASES , SLT ,ETT ,GOT ,GOQ , , , , , ,GPLS , USET ,SILS ,PJ ,EDTs ,YS , GM , ,KFS ,KSS ,QR , , , ,MAR ,MEA , DYNAMICS,BGPDTS ,CSTMS ,MPTS ,DIT , EST ,GEOM2S ,GEOM3S ,ECTS ,EPTS , INDTA ,KELM ,KDICT ,GPECT ,VELEM , ,ditid ,pvtbc ,scstm , , ,GEOM4S ,PG , , , ,EPT ,MPT ,GEOM1 ,GEOM2 , GEOM3 ,GEOM4 ,PTELEM ,MELM ,MDICT , , ,medge ,viewtb , , bgpdtvu ,gpsnts ,pvt ,deqatn ,deqind , gdntab ,oint ,pelsets ,KSF ,KMG , MMG ,MSF ,BMG ,BSF ,K4MG , K4SF ,K2MG ,M2MG ,B2MG ,K2SF , M2SF ,B2SF ,qsgf ,qmgf , , ,,,,, , ,matpool , , , folt , , , , , mss ,bss ,k4ss ,ypfo1 , , , , , ,vgq , xsop2dir, , , , , mmcdb ,geom1qx ,meh ,SESE0f ,KESE0f , DESE0f ,kaa ,maa ,baa ,cmlama1 , , , ,matpools,gei , rgy , / AUPF ,AQPF ,aqmpf , ,iUG1 , iQG1 ,iEF1 ,iES1 ,iEE1 ,iUG2 , iQG2 ,iEF2 ,iES2 ,iEE2 , , ies1mc ,ief1mc ,iee1mc ,ies2mc ,ief2mc , iee2mc , / APP /APP1 /RSONLY /FALSE /FALSE / AERO /dropt /FALSE /S,PFILE /S,CARDNO/ 0 /FALSE /0 /pexist /0 / false /freqdep /false /0 /false / soltyp /false /false /false /spdr / false $

Known Error

CR 1-17280829

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Documentation/QRG - Release Guide, ASSIGN - Output2 Example 4 under the ASSIGN FMS statement is incorrect. The current example is as follow: assign op2 bigendian' ... assign op2='test_op2.12' unit=12 assign op2='test_op2.35' unit=35 form=formatted

Description

The op2 logical name is assigned to unit 12 and this unit number should not be changed on the assign statement. This is usually used for param,post1 and param,post,-2. The example should be modified as follow: assign op2 bigendian ... assign op2='test_op2.12' assign output2='test_op2.35' unit=35 form=formatted

Known Error

CR 1-17280840

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Superelement - SELR, method - SFM 9104 In a static supelement analysis run, if case commands METHOD=n and seqset1 entries are included in the model, the job may fail with the following unclear messages:

Description

^^^ USER FATAL MESSAGE 9104 (SELR) ^^^ THERE IS NO COUPLING BETWEEN INTERIOR POINTS OF THIS SUPERELEMENT AND ITS BOUNDARY POINTS. ^^^ USER ACTION: ADD SOME ELEMENTS CONNECTING THE INTERIOR AND BOUNDARY POINTS. Avoidance: Removing either the method command or the seqset1 entries will avoid the error. Note that neither one of these entities are used in sol 101 so the error is very unlikely.

Known Error

CR 1-17282301

Known Error

CR 1-17282301

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

File Management Section - DBLOCATE - SFM 1013 Three successive DBLOCATE commands, the first 2 with NOCOPY and the last one with the COPY option, results in the following fatal message:

Description

*** SYSTEM FATAL MESSAGE 1013 (GBKMGX) CANNOT FIND CORRECT CLUSTER POINTER RECORD BIOMSG: ERROR 4276 HAS OCCURRED IN ROUTINE GBKMGX , FILE INDEX = 0. STATUS = 0

Avoidance: Do not mix COPY and NOCOPY options. Known Error

CR 1-17297801

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Distributed Memory Parallel - EXTSEOUT - SFM 3008 UTMCOR In MSC.Nastran 2004r3(2004.5) a dmp run with external superlements may fail with the message: *** SYSTEM FATAL MESSAGE 3008 (UTMCOR) MODULE = MDENZO INSUFFICIENT CORE AVAILABLE FOR SUBROUTINE ENZO2 PROGRAMMER INFORMATION: LOCATION KEY = READ IN P

Description

Avoidance: Run without dmp or apply the following alter: compile cmpmode alter 'call mdacms ' (,-1) $ if( nproc>0 ) putsys(nproc,231) $ alter 'if ( fdcmrrs', '' $ if ( fdcmrrs OR mdacms ) then $ alter 'paraml cmphixz', '' $ paraml cmphixz//'trai'/1/s,n,nozset $

Known Error

CR 1-17297961

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Installation - FLEXlm installation not handled correctly on hpia64

Description

The current 'mscsetup' script correctly accounts for the hpuxia64 being

Known Error

CR 1-17297961 distinct from hpux, as far as Patran and Nastran installs are concerned, however, when installing a FLEXlm server, the scripts in the .../msc/bin directory (flexlm, lm*) are based off an older mscsetup that does NOT account for the distinction as such, running those scripts on an IA64 will still search for the default 'hpux' location, when the install actually created an 'hpuxia64' folder, and the script will fail

Known Error

CR 1-17303819

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

DMAP/Matrix Methods - SMPYAD method ABA wrong results for complex matrices The SMPYAD module ABA method produces wrong results for complex matrices under the following conditions:

Description

1. Spill (multiple passes) used. 2. Triple loop kernels used. Avoidance: Set sys129=1 to bypass the ABA method.

Known Error

CR 1-17303823

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Acoustics - METHOD(FLUID) - Missing output and wrong answers

Description

For acoustics, if a METHOD(fluid) entry is not present in the Case Control, the fluid eigensolution is not performed. This conflicts with design intent and Remark 3 under the METHOD command in the QRG. Avoidance: Specify a METHOD(FLUID) entry in Case Control.

Known Error

CR 1-17322311

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Description

Buckling Analysis - multiple buckling subcases - UWM 73, Wrong answers In buckling analysis UWM 73 will be issued if there are more than two buckling subcases in the following solution sequence: 1. SOL 105 with scr=no 2. SOL 200 with ANALYSIS=BUCK regardless of scr keyword Avoidance: Insert the following DMAP alter:

Known Error

CR 1-17322311 compile super3 alter 'DBVIEW qGFs=qG' DBVIEW UGFb=UG WHERE (( (seid>0 and peid>0 and spc=* and mpc=* and suport=* and bmeth=* and mtemp=* and p2g=* and k2gg=* and m2gg=*) or (seid=0 and peid=0 and spc=cspc and mpc=cmpc and suport=csuport and bmeth=cmeth1 and p2g=cp2g and k2gg=ck2gg and m2gg=cm2gg and mtemp=cmtemp) )) $ DBVIEW qGFb=qG WHERE (( (seid>0 and peid>0 and spc=* and mpc=* and suport=* and bmeth=* and mtemp=* and p2g=* and k2gg=* and m2gg=*) or (seid=0 and peid=0 and spc=cspc and mpc=cmpc and suport=csuport and bmeth=cmeth1 and p2g=cp2g and k2gg=ck2gg and m2gg=cm2gg and mtemp=cmtemp) )) $ alter 'SEP4 CASESEP4' else if ( app1='bkl1' ) then $ SEP4 CASESEP4,PCDB,EMAP,XYCDB,UGFb,PUGF,QGFb,mmcdb/ DRLIST/ APP4/'SEID'/S,N,NODRALL/S,N,SEID0/S,N,NOUPL/CNTL $ alter 'DBVIEW UGs=UG ' DBVIEW UGb=UG WHERE (( (seid>0 and peid>0 and spc=* and mpc=* and suport=* and bmeth=* and mtemp=* and p2g=* and k2gg=* and m2gg=*) or (seid=0 and peid=0 and spc=cspc and mpc=cmpc and suport=csuport and bmeth=cmeth1 and p2g=cp2g and k2gg=ck2gg and m2gg=cm2gg and mtemp=cmtemp) )) $ alter 'NUGDWN=(NOGO=-1' else if ( app1='bkl1' ) then $ SEDR EMAPX,CASEX,PCDB,DRLIST,XYCDB,SLT,ETT, MAPSF,UGb,BGPDTSD,GDNTAB,,/ ULS,CASEDR,PCDBDR,XYCDBDR,,/ APP4/SEID/S,N,NOUP/S,N,NOSRT1//S,N,NOOUT/ S,N,NOPLOT/S,N,NOXYPLOT/'SEID'/NCUL $ NUGDWN=(NOGO=-1 AND SEID0) $ must appear right after sedr endalter

Known Error

CR 1-17370601

Known Error

CR 1-17370601

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Optimization/Design Sensitivity - MFREQ, DFREQ, scr=no - Wrong Answers Direct or modal frequency response optimization may produce different optimization results if scr=no is used. Avoidance : Use scr=yes

Description

A related problem has surfaced with a external se deck from GM. The client deck itself is not available. However, the problem can be reproduced with d200pe3 with resvec=no. Adding adelufx to the dbdelete fxied the problem. Or, scr=yes also does the trick.

Known Error

CR 1-17373002

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Enforced Motion - SPCD - Enforced motion in a subset of subcases results in SFM 5423. If a frequency response job with more than one subcase has an SPCD enforced motion specified in only a subset of the subcases, the job terminates with SYSTEM FATAL MESSAGE (SFM) 5423 in the MPYAD module.

Description

Avoidance: If a frequency response job with more than one subcase is to have SPCD enforced motion specified in only a subset of the subcases, define VERY SMALL enforced motion in those subcases where such enforced motion is not really needed.

Known Error

CR 1-17373523

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Description

Elements - PBEAML, MAT8 - Poor Message, Missing UFM 2113 If a pbeaml entry incorrectly references a MAT8 entry a "Fatal Error" without any further information will be output in V2004.0.6. In V2001.0.9 the same job produces a better message*** USER FATAL MESSAGE 2113 (EMG) ELEMENT 1 REFERENCED MATID 1 WHICH CANNOT BE USED TO OBTAIN REQUIRED PROPERTIES. Avoidance: Other than correcting the input there is no avoidance.

Known Error

CR 1-17378501

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Nonlinear Analysis - PCOMP, TEMP(MAT) - Wrong Answers

Description

Unsymmetric composite layups with temperature-dependent materials may produce wrong answers in nonlinear analysis. Avoidance: There is no avoidance.

Known Error

CR 1-17384835

Product

MSC / MD Nastran

Corrected Version 2005.5 Abstract

Aeroelastic Analyis - Attempt to trim with no mass matrix. If a solution 144 trim analysis is executed on a model with no mass the following fatal message that does not describe the problem will occur:

Description

*** SYSTEM FATAL MESSAGE 6144 (PARTN1) THE SIZES OF THE INPUT MATRICES AND PARTITIONING VECTORS ARE INCOMPATIBLE. SPECIFICALLY: The number of columns in PUXLRPV is not equal to the number of rows in the column partitioning vector PVPR User Information: Size of input matrix and partitioning vectors: PUXLRPV : Rows= 2 by Cols= 9 PVPR : Rows= 11 An attachment contains a version of the AEMR.dmap that traps the missing mass matrix. Note: This same error can occur if the PARAM, WTMASS is set to zero or 0.0. It is the same effect as not having mass. This error may be slightly more prevalent in Flight Loads. The reason being is the ability to use equations on some of the flight loads forms is not available. An example would be for the Forward Swept Wing airplane. The direction say to use feet instead of inches for acceleration. So instead of WTMASS being 1/386 or the common .00259, one should be able to enter `1/32.14`. In regular Patran this is acceptable, and will return 0.031081. Flight Loads just writes .0

Known Error

CR 1-17386627

Product

MSC / MD Nastran

Corrected Version 2005

Known Error

CR 1-17386627

Abstract

Miscellaneous - SWM 6498 UFM (1) - Unclear message Corrected usrmsg.F to increase dimension of array from 9 to 10. (cdp 8/24/04) If degrees of freedom are defined illegally in a set (e.g., constraining an dependent dof), the job should fail with a message similar to the following messages: USER FATAL MESSAGE 2101 (GP4) +165 GRID POINT 530 COMPONENT 1 ILLEGALLY DEFINED IN SETS UM US However, in v2004.5, the job may fail with the following unclear messages Windows machine. *** SYSTEM WARNING MESSAGE 6498 (MsgGen) Message number was not found.

Description PROGRAMMER INFORMATION: Check call to MSGPOP from GP4 with message number 538976288.0. Severity is 'USER FATAL MESSAGE' (1) %1: ' 530' %2: ' 1' %3: ' UM' %4: ' US' %5: ' ' %6: ' ' %7: ' ' %8: ' ' %9: ' ' %10: '' Avoidance: Correct the offending entry Known Error

CR 1-17395103

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Description

DMAP - MPYAD - incorrect data in UFM 5423 If the MPYAD module issues SFM 5423, the message may contain an incorrect data block name specified in a prior execution of MPYAD. For example, in the following DMAP: MATGEN ,/A/4/4/3 $

Known Error

CR 1-17395103 MATGEN ,/B/4/3/4 $ MATGEN ,/C/4/3/3 $ MPYAD A,B,C/D $ MPYAD A,B, /E/1 $ the 1st multiply runs OK but the 2nd mpyad fails and references the C matrix in the first mpyad. SYSTEM FATAL MESSAGE 5423 (DMPYAD) ATTEMPT TO MULTIPLY INCOMPATIBLE MATRICES Avoidance: There is no avoidance.

Known Error

CR 1-17417801

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Complex Eigenvalue - CEAD - Eigenvector spill logic in complex Lanczos causes hard crash. The multishift logic in the complex branch of the complex Lanczos method suffers a hard crash when the eigenvectors spill.

Description Avoidance: The avoidance is to increase memory or to use the old single vector complex Lanczos. Known Error

CR 1-17432001

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Optimization/Design Sensitivity - DRSPAN, DOPR3 - SFM 4276

Description

When an optimization job includes both DRSPAN subcases mixed with nonDRSPAN subcases, the job may fail with SFM 4276 with error code = 3001 in the DOPR3 module. Avoidance: Rearrange the subcases so that the non-DRSPAN subcases are put at the top of the DRSPAN subcases.

Known Error

CR 1-17446201

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Aeroelastic Analysis - DMIK

Description

The DMIK bulk data input provides a convient way of entering correction

Known Error

CR 1-17446201 data related to the aerodynamic model. At present, this is supported only in SOL 144 and SOL 200 and is not supported in SOL's 145 and 146. Avoidance: The DMI equivalents of these matrices can be input or the following dmap avoidance can be applied to add the MATPOOL datablock in the call to PFAERO. The alter below applies to SOL 145 with a similar alter required for 146: CALL PFAERO cases ,EDTS ,ects ,bgpdts ,DMI , DMINDX ,PCDBS ,acpt ,aero ,matpool , mklist ,aempcomp,aemonpt ,saemprk ,control , aecomp ,cstma ,aebgpdts,mpjsfn2o,mpjn2o , aeusets / lajjt ,uajjt ,ajj0 ,wskjf ,D1JK , D2JK ,d1je ,d2je ,skj , , ,,,,, ,WKK , , , , ,,/ 'DYNAMICS'/IMACHNO/IKBAR /S,PFILE /SKPAMP $

Known Error

CR 1-17446504

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Rotordynamics - TRD1 - Traceback in TRD1 Rotordynamcis may fail in trd1 with a traceback.

Description Avoidance: There is no avoidance. Known Error

CR 1-17446507

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Rotordynamics - ROTORG, NLTRD2, CDAMPi, CVISCi, UNBALNC - Wrong Answers, Damping Ignored

Description

The rotor damping (CDAMPi, CVISCi) should add instability to transient response but damping is effectively not included.

Known Error

CR 1-17469004

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Rigid Elements - AUTOMSET, DECOMP, UFMPACK - HPUX IA64 under Nastran 2004r3

Known Error

CR 1-17469004 Large models with automset may fail with the message below on Itanium running HPUX. From the f04 file

Description

Your use or distribution of UMFPACK or any modified version of UMFPACK implies that you agree to this License. THIS MATERIAL IS PROVIDED AS IS, WITH ABSOLUTELY NO WARRANTY EXPRESSED OR IMPLIED. ANY USE IS AT YOUR OWN RISK. From the log file: FATAL ERROR: thread: 1 routine: sysrcv reason: signal recvd error: -4 Avoidance: The only avoidance is to use version 2005.

Known Error

CR 1-17482902

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Submittal - libpath set incorrectly when exe= specified with no directory

Description

Fixed in round 16. When using nastran script with exe= keyword to override the default executable, if the pathname of the executable does not have any directory compoment specified, then the libpath will not include the correct directory path.

Known Error

CR 1-17497305

Product

MSC / MD Nastran

Corrected Version 2005.5 Abstract

Rigid Elements - RIGID=LAGRAN - SFM 5483 RIGID=LAGRAN 3000 grid limit Models with RIGID=LAGRAN and more than 3000 points attached to a rigid element will fail with the following message:

Description

*** SYSTEM FATAL MESSAGE 5483 (TA1H) ROUTINE NEEDS TO BE UPDATED, IT DOES NOT SUPPORT ELEMENTS WITH GRIDS MORE THAN = 3000

Known Error

CR 1-17497318

Product

MSC / MD Nastran

Corrected Version 2005.1 Abstract

Rigid Elements - RIGID=LAGRAN, RBE3 - Traceback in EMG Models with RBE3s and RIGID=LAGRAN may fail with a traceback in EMG.

Description

Traceback: Offset 0x00000030 in procedure dminit_ Offset 0x00000288 in procedure dmnewb_ Offset 0x000000ec in procedure emgsoc_ Offset 0x000002ac in procedure emg_ Offset 0x00000108 in procedure xsem09_ Offset 0x00000194 in procedure xsemdr_ Offset 0x0000005c in procedure nastmon_ Offset 0x00000a2c in procedure mainal --- End of call chain --****************** Fixed V2005.1.0

Known Error

CR 1-17505001

Product

MSC / MD Nastran

Corrected Version 2005.5 Abstract

Description

External Superelements - EXTSEOUT, different ID - missing connection For external superelement using the EXTSEOUT command, the boundary points for the assembly structure at which the components will be attached are generated in the ASMBULK file. It is also assumed that the boundary IDs for the component and the assembly structure are the same. If the boundary IDs are not the same, then the structure may not be connected as intented. Avoidance: If the boundary IDs for the component and assembly structure are different, do not use the ASMBULK file, but create a SEBULK entry using the automatic feature instead. This problem has been resolved in Version 2006 by the incorporation of a new option called ASMBULK=AUTO for the EXTSEOUT Case Control command.

Known Error

CR 1-17506102

Product

MSC / MD Nastran

Corrected Version 2001.0.9 Abstract Description

Aeroelastic Analysis - TRIM, AELINK - UFM 5266 (ASGPRS) In aeroelastic analysis the following misleading message may be issued:

Known Error

CR 1-17506102 USER FATAL MESSAGE 5266 (ASGPRS)TOO MUCH DATA ON TRIM OR AELINK BULK DATA ENTRIES. when the message that should be issued is: *** USER FATAL MESSAGE 7526 (ASGPRD) AN INVALID TRIM TASK HAS BEEN POSED. THERE ARE 2 FREE AESTAT DEGREES OF FREEDOM BUT ONLY 1 SUPPORTED DEGREES OF FREEDOM. USER ACTION: SPECIFY A VALID TRIM TASK BY EITHER ADDING SUPPORTED DEGREES OF FREEDOM OR BY REDUCING THE NUMBER OF FREE AESTAT DEGREES OF FREEDOM.

Known Error

CR 1-17510409

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Miscellaneous - MEM - 'Unable to allocate /XNSTRN/ Open Core (memory) on Windows XP MSC.Nastran requires that contiguous memory be allocated. MSC.Nastran requires dlls be loaded and these dlls use open core. The various Windows o/s may allocate the required open core differently causing more or less memory to be available for nastran. Windows XP has been found to allocate the memory in such a way that only 1100mb of contiguous space is left for nastran. MSC.Nastran V2005 dummys out unneeded FLEXlm dlls and this allows more memory to be allocated. Thus, this problem is considered partially addressed in Version 2005. MSC will continue to investigate more efficient ways to allocate memory.

Description Note that it is a limitation of all Windows based operating systems that other applications that are executing will impact the amount of open core that can be allocated. MSC.Nastran V2005 has been further enhanced to improve dll management to maximize the available open core. Currently, it appears that MSC.Nastran can now access approximately 1.8GB of open core on all versions of Windows XP. Known Error

CR 1-17527801

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3)

Known Error

CR 1-17527801

Abstract

Superelements - PARAMs AUTOQSET and Bulk Data entries SECSETi and SEBSETi - Possible wrong answers When using the autoqset feature (PARAM,AUTOQSET,YES) , the system modes may be incorrect if one of the component modes is free-free or fixed-free (see SECSETi, SEBSETi). Avoidance: Insert PARAM,MHRED,NO and, if running V2005r2 or earlier, the following DMAP alter:

Description

$ alter is needed for only V2005r2 or earlier compile semr3 alter 'call semr4'(3),'' call semr4 pg,uset,gm,ksf,bsf,msf,ys,drg,mff,cmpho,lyy,kyy, cmlama,moo,koo,got,cmphrc,vvfs,cmmi,vyv,,bjj,sils, eqexins,rvg,cmeigmat,vgq,pmyg,pbyg,pkyg,cases,, resldo,vvy,gotf,vgfs/ goq,cmlama1,cmemat,mq/ norc/nomvjjs/s,dotrip/fluid/nasout/0/error/ genrldo/splitfs $ endalter

Known Error

CR 1-17557511

Product

MSC / MD Nastran

Corrected Version 2004.5 Abstract

Nonlinear Analysis - CTETRA, MATT - Temperature-dependent material , sdr2 - job aborts In version 2004, if a nonlinear model contains tetra elements and temperature-dependent material properties are used, then the job may abort in SDR2 with the following unclear messages:

Description

MAIN: The FPU has been reset after floating point exception. MAIN: For reference, A(MAINAL) = 73C3B0, This error is fixed in Version 2004.5. Avoidance: Removing either the temperature-dependent material or replacing the tetra elements with hexa elements avoids this error.

Known Error

CR 1-17575313

Product

MSC / MD Nastran

Corrected Version 2004.0.7

Known Error

CR 1-17575313

Abstract

File Management Section - ASSIGN, INPUTT2 - SFM 6551 An FMS ASSIGN statement to UNIT=300 may fail on linux with the message:

Description

*** SYSTEM FATAL MESSAGE 6551 (INPTX2) A READ ERROR WAS DETECTED ON UNIT 300 DURING BINARY INPUTT2 PROCESSING PROGRAMMER INFORMATION: 1. A KEY VALUE WAS NOT BEING READ 2. THE LAST KEY VALUE READ: 2 3. THE FORTRAN READ IOSTAT CODE IS 154 Avoidance: Use a different unit number

Known Error

CR 1-17584301

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Performance - Poor performance for unsymmetric FBS for uncoupled matrices

Description

The performance for unsymmetric FBS is poor when the matrices have very little coupling (i.e. very sparse RHS matrix). In this case, the code should select the special "MCE1-only" sparse FBS.

Known Error

CR 1-17604301

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Data Recovery - GPFORCE, SUBCOM - Missing output If GPFORCE is requested in a SUBCOM then "F-OF-SPC" may not be printed in the SUBCOM's grid point force balance output. Avoidance: Insert the following alter:

Description COMPILE sedrcvr alter 'GPFDR CASEDR,UG,KELMX'(,-1) paraml qmg//'null'////s,n,nullqmg $ if ( nullqmg=-1 ) delete /qmg,,,, $ endalter Known Error

CR 1-17620501

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Superelements/Frequency Response - DELAY, SPCD - SFM 4276 in DPD (in SEDLG subdmap)

Known Error

Description

CR 1-17620501 A SOL 111 superelement job employing DELAY data and SPCD enforced motion fails with SYSTEM FATAL MESSAGE 4276 (ERROR CODE 3021) on a call to the DPD module in the SEDLG subdmap during data recovery.

Known Error

CR 1-17647514

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Postprocessing - PARAM,POST,0 - GRIDX is not present in XDB for Collector Superelements

Description

THE GRIDX datablock is not present in the XDB when the superelement is a collector containing no elements.

Known Error

CR 1-17663601

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

External Superelements - EXTSEOU, PSDF - Missing PSDF output in assembly run. When using the EXTSEOUT feature, the assembly run does not output the PSDF responses for velocities and accelerations for the external superelement.

Description

Avoidance: Insert the following DMAP alter in the assembly run: compile sedrcvr alter 'Multiply OTM' splitdva=-1 $ endalter

Known Error

CR 1-17664010

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Inertia Relief - param,inrel,-2 - Model with no mass does not issue UFM A model with no mass defined may only issue a max ratio warning message and continue when using param,inrel,-2. The job should issue a meaningful fatal message.

Description +++++++++++++++++++++++++ A correct warning message is found in V2005.0.0. -TIN-

Known Error

CR 1-17664010 ^^^ USER FATAL MESSAGE 9088 (SELG) ^^^ PARAM,INREL,-2 IS PRESENT BUT NO MASS IS DEFINED. 1

Known Error

CR 1-17670502

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Size Limitation - DCMP - Floating point exception error in DCMP for large models In MSC.Nastran Version 2004.5, large models may fail in decomp on 64 bit aix systems (AIX 5 and above).

Description

SIGTRAP - Trace trap Signal generated for floating-point exception: FP invalid operation.

Known Error

CR 1-17673201

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

File Management Section - ASSIGN with DELETE option fails - UFM 1277 or UFM 773 In Version 2004.0.7 and 2004.5.0 only: If the DELETE option is used on an ASSIGN MASTER statement and the file already exists, then the file assigned to MASTER is NOT deleted and UFM 1277 is issued. ASSIGN MASTER='model.MASTER', DELETE ASSIGN DBALL='model.DBALL', DELETE $

Description

*** USER FATAL MESSAGE 1277 (DBDEF) THE FILE ASSIGNED TO LOGICAL NAME = MASTER IS NOT A VALID MASTER DBSET FOR A PRIMARY DATABASE. USER ACTION : VERIFY THE FILE NAME SPECIFIED ON THE ASSIGN MASTER STATEMENT. 0FATAL ERROR In Version 2004.0.7 and 2004.5.0 only; If the DELETE option is used on an ASSIGN for a non-MASTER file (e.g. DBALL) and that file exists, then the DELETE is ignored and UFM 773 is issued: ASSIGN MASTER='model.MASTER'

Known Error

CR 1-17673201 ASSIGN DBALL='model.DBALL', DELETE ENDJOB *** USER FATAL MESSAGE 773 (DBDEF) THE FOLLOWING PHYSICAL FILE ALREADY EXISTS. LOGICAL NAME = DBALL PHYSICAL FILE = model.dba USER INFORMATION: NO ASSOCIATED DEFAULT FILES OR ASSIGNED DBSETS CAN EXIST PRIOR TO THE DATA BASE INITIALIZATION RUN. USER ACTION: DELETE THIS FILE AND RESUBMIT THE JOB. Avoidance: Manually remove all files used on ASSIGN statements prior to run

Known Error

CR 1-17706203

Product

MSC / MD Nastran

Corrected Version 2005.5 Abstract

Materials - MCSID - UFM 2025 Large, eight digit, MCSID IDs may incorrectly lead to UFM 2025.

Description

*** USER FATAL MESSAGE 2025 (TA1) UNDEFINED COORDINATE SYSTEM ID = 50500099 Avoidance: Use smaller ids.

Known Error

CR 1-17724607

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Optimization/Design Sensitivity - MFLUID - SFM 1126 If an optimization model contains MFLUID entries, the job will fail with the following messages.

Description

*** USER FATAL MESSAGE 1126 (GNFIST) DMAP MODULE MGEN IS ATTEMPTING TO OUTPUT DATABLOCK 204 NAME = MAR , WHICH ALREADY EXISTS. USER ACTION: DELETE THE DATABLOCK, OR USE FILE MAR=OVRWRT Avoidance: Insert the following alter. compile phase1a alter 'delete.*\/belm' delete /mar,,,, $ endalter $

Known Error

CR 1-17727701

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Dynamics - DELAY - SFM 3002 (DPD), Specifying DELAY for dof with no excitation

Description

Specifying DELAY data for DOFs without any excitation may lead to SYSTEM FATAL MESSAGE 3002 on a call to SKPREC in the DPD module.

Known Error

CR 1-17733738

Product

MSC / MD Nastran

Corrected Version 2005.5 Abstract

Documentation/QRG - PBEND - Remark 3, FSI=1, Wrong Description Remark 3 under the PBEND description in the QRG incorrectly and incompletely describes the equation for FSI=1. It should read as follows:

Description

The flexibility factor is set to unity. The stress intensification factor in plane 2 using the general or alternate format is set to unity and for plane 1 it is set as follows: [equation] where r-elem is C1, D1, E1 or F1 of the stress points. If any of these values are exactly zero, then S1 is set to unity.

Known Error

CR 1-17749511

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Loads - TEMP - Wrong Answers

Description

Remark 2 under the QRG description of the TEMP entry indicates that; Set ID MUST be unique w.r.t all other LOAD-type entries if TEMP(LOAD) is used. However, this is not enforced as a fatal error and can lead to wrong answers.

Known Error

CR 1-17764701

Product

MSC / MD Nastran

Corrected Version 2005.1 Abstract

Optimization/Design Sensitivity - Multiple Static Aero Subcases Incompatible Matrices, SFM 4276

Description

If a SOL 200 run is made with multiple static aero boundary conditions and the subcases have different externally applied loads, the sensitivity analysis can produce either wrong answers and go down paths that cause the solution

Known Error

CR 1-17764701 to fail with a message that indicates incompatible matrices or a divide by zero errors. Avoidance: One avoidance is to remove the external loads. A more complete avoidance is to make the following NDDL change: PATH ULNDEL SEID,PEID,MPC,SPC,SUPORT, DESITER,PVALID,APRCH,HIGHQUAL, AUXMID,ADJOINT,DESINC,DISCRETE $ METH

and make the following dmap alters: compile fea alter 'bcdr'(5),'bcdr'(5) BCDR CASEM//SEID/' '/0//true/ S,N,SPC/S,N,MPC/S,N,SUPORT/s,n,load///S,N,BC $ compile pslgdv alter 'bcdr'(2),'bcdr'(2) BCDR CASEM//SEID/' '/0//true/ S,N,SPC/S,N,MPC/S,N,SUPORT/s,n,load///S,N,BC $ alter 'bcdr'(8),'bcdr'(8) BCDR CASEbc//SEID/' '/s,n,nskip//s,n,bcflag/ S,N,SPC/S,N,MPC/S,N,SUPORT/s,n,load///S,N,BC $ alter 'segoa'(2) dbstatus auads//s,n,noaua $ alter 'nopa'(8),'' if ( nopa 0) then $ alter 'pav' NSKIPL=NLOADS+NSKIPL $ LOADS ACCUMULATOR alter 'pmav' nskplm=nloada+nskplm $ unrestrained loads accumulator alter 'nskplm'(4,-1),'nskplm'(4) compile gendv2p alter 'nddl','nddl' TYPE PARM,NDDL,I,N,MPC,SPC,suport,templd,deform ,load $ alter 'bcdr','bcdr' BCDR CASE0//0/' '/ S,N,NSKIP/S,N,NLOADS/S,N,BCFLAG/ S,N,SPC/S,N,MPC/S,N,SUPORT/s,n,load////-1 $ compile xsedrdr alter 'bcdr','bcdr' BCDR CASEbc//SEID/' '/s,n,nskip//s,n,bcflag/ S,N,SPC/S,N,MPC/S,N,SUPORT/s,n,load///S,N,BC $

Known Error

CR 1-17766002

Product

MSC / MD Nastran

Corrected Version 2007.0.0 (MD R2) Abstract

Documentation/Case Control - SET - Possible Traceback in sdr2c

Description

Depending on the use the SET Case Control command may contain a list of integers or a list of real numbers. However, there is no application where the list would contain both integers and real numbers. MSC.Nastran does not know the intent of the set until it is referenced. If a set contains integers when it should contain real numbers or vice versa, the nastran may issue a traceback. A traceback has been encountered in sdr2c but other routines are possible.

Known Error

CR 1-17767304

Product

MSC / MD Nastran

Corrected Version 2005.1 Abstract

Documentation/QRG - ADAMSMNF - SWM 7804 - No stresses/strains written to ADAMS mnf file Attempt to output solid element strains (CHEXA, CPENTA, CTETRA) into the Adams mnf file using the ADAMSMNF command will not work and will result in the message:

Description

SYSTEM WARNING MESSAGE 7804 (AFERRM) THE ADAMS/FLEX MNF GENERATION MODULE INPUT GRID POINT STRAIN DATA BLOCK OFP TABLE CODE IS NOT RECOGNIZED. OFP TABLE CODE IS 28. REQUEST FOR GRID POINT STRAIN OUTPUT IS IGNORED. No stresses or strains are written. Avoidance: Do not use PRINCIPAL on the VOLUME command. Explicitly use DIRECT to output stresses/strains into the mnf file. It is a restriction in the ADAMS/Flex interafce that it accepts only direct stresses and not principal. The ADAMSMNF command in the QRG needs a comment to this effect.

Known Error

CR 1-17769313

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Submittal - Estimate fails with Access Violation on Window Estimate may fail with an Access Violation message on Windows.

Description

Avoidance: Specify mem= on the nastran submittal line so that estimate does not run.

Known Error

CR 1-17776102

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Performance - Krylov performance may suffer due to DOF-based ordering

Description

The Krylov solver uses CFACTR to do the decomp for frequency response. This path to decomp uses degree-of-freedom based ordering. It should call CFACTR2 instead which uses grid based ordering.

Known Error

CR 1-17777901

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Description

Performance - FASTFR check in GMA not correct If any structural matrices are missing, for example there are no fluid elements, the check in GMA to determine if FASTFR can be used is not correct. This may lead to slower run times. dfbella>>> New checking implemeted.

Known Error

CR 1-17790001

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

SOL 600 - Temperature Loading with offs gives wrong results

Description

For SOL 600 an option has been added to apply thermal loading at the original node, the offset node or both. This is activated by a new parameters in Nastran 2005 named marcofft and moffcore. The defaults for these new parameters cause the temperature loading to be applied at both nodes. Models now gets the same thermal strains using SOL 600 and 106.

Known Error

CR 1-17793896

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Nonlinear Analysis - PARAM SRCOMPS Does Not Work

Description

Nastran PARAM SRCOMPS, strenth ratio for composite analysis, does not work for nonlinear analysis.

Known Error

CR 1-17812511

Product

MSC / MD Nastran

Known Error

CR 1-17812511

Corrected Version 2005.0.2 Abstract

DBC - PARAM,NOCOMPS,-1 - DBC Module, Access Violation Data decks with param,nocomps,-1 may fail in the DBC module in routine dbcgps.

Description Avoidance: Do not use param,nocomp,-1 for 2004 and later systems since it has no meaning any more. The only valid number are 0,1,2. Known Error

CR 1-17812519

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract Description

Composites - STRAIN, PCOMP - SFM 3005 (SDR2) A request of only strain output for composite elements causes SDR2 to issue SYSTEM FATAL MESSAGE 3005. Avoidance: Add a STRESS request.

Known Error

CR 1-17818401

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Description

Elements - CBAR, CBEAM - UFM 2026 when BGG, BGE, or BEE is specified for OFFT UFM 2026 indicating illegal geometry is generated for CBAR/CBEAM elements when the orientation vector for the element is defined using the reference grid point (G0) option and the OFFT (field 9) value specifies BASIC (Bxx codes) for the orientation vector. Avoidance: Specify GLOBAL (Gxx) code for the orientation vector.

Known Error

CR 1-17835201

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Buckling - Multiple buckling subcase - SFM 3002 in GPSP

Description

Solution 105, buckling, may fail in MSC.Nastran 2004 with SYSTEM FATAL MESSAGE 3002 in the GPSP module if multiple buckling subcases exist.

Known Error

CR 1-17845802

Product

MSC / MD Nastran

Known Error

CR 1-17845802

Corrected Version 2005 Abstract

Rotordynamics - LOAD, RFORCE - Wrong Answers In a static analysis with rotors, the gyroscopic moments may be missing from the load vecotr if the LOAD Case Control Command references a LOAD Bulk Data Entry.

Description Avoidance: The LOAD Case Control Command should reference the RFORCE Bulk Data Entry directly without using the LOAD Bulk Data Entry. Known Error

CR 1-17865308

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Optimization/Design Sensitivity - PARAM,XYUNIT,PUNCH(NEWBULK) - No punch file written, csv incomplet The DOM12F subroutine does not place any limits on the length of a record created that is to be written to the csv file. Machine limits exist and the program needs to be redesigned to write within these limits. Error message on AIX:

Description

1525-005 The formatted I/O statement on the internal file cannot be completed because the end of the record was reached. The program will recover by ignoring the remaining data items in the I/O statement. XL Fortran (initialization): Out of memory. time: command terminated abnormally. Error on 32bit Linux: Input/Output Error 154: Wrong length record In Procedure: dom12f At Line: 319 Statement: Formatted WRITE Unit: Internal File Record Number: 1

Known Error

CR 1-17867401

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Acoustics - param,panelmp - Panel grid Mode Participation Factor output incorrect

Description

Structure Mode Participation Factor output for panel grid points is incorrect if any fluid grid point id is less than the largest id of the structural

Known Error

CR 1-17867401 grid points in the problem. All other MPF output is accurate. Avoidance: Make sure that all fluid points have IDs greater than the largest ID of the structure grid points.

Known Error

CR 1-17870204

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Rotordynamics - SPARSEDR - SFM 6143 (UMRGE1) SOL 108 with superelements and rotordynamics may fail with the folloiwng message:

Description

*** SYSTEM FATAL MESSAGE 6143 (UMRGE1) THE SIZES OF THE INPUT MATRICES AND THE DOF SETS ARE INCOMPATIBLE. SPECIFICALLY: The number of rows in RXMG is not equal to the size of the M-set User Information: Size of input matrices and DOF sets: RXMG : Rows= 129 by Cols= 153 Set sizes: Major (G-set)= 5796 Set0 (M-set)= 1988 Set1 (COMP-set)= 3808 Avoidance: Insert param,sparsedr,no or following DMAP alter compile fdrmgen alter 'equivx rxmgx\/rxmg','' alter 'paraml rmgg' if ( spdrm ) then $ equivx rxmgx/rxmg/-1 $ delete /rgm,,,, $ trnsp rxmg/rgm $ endif $ endalter

Known Error

CR 1-17883701

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Optimization/Design Sensitivity - PCOMP, MAT8, DVMREL - UFM 316

Description

Punched output from a SOL 200 analysis that uses DVMREL optimize PCOMP and MAT8 may contain invalid data and cause a subsequent nastran job to fail with USER FATAL MESSAGE 316.

Known Error

CR 1-17889001

Product

MSC / MD Nastran

Known Error

CR 1-17889001

Corrected Version 2005 Abstract

Rigid Elements - PARAM,AUTOMSET,YES fails with multiple boundary conditions or SOL105 Runs with PARAM,AUTOMSET,YES could fail in SOL 105 or with multiple BC with UFM 1126 (GNFIST) (matmod attempting to output GM which already exists).

Description

Avoidance: compile sekr0 alter 'xmce1',''(,1) TYPE PARM,NDDL,CHAR8,Y,automset $ IF ( NOGM=-1 or automset='yes' ) then $ if ( automset='yes' ) delete /gm,,,, $ call xmce1 USET1,RMG1,KGG/GM,nuset/rsonly $ dbstatus nuset//s,n,nonuset $ IF ( getsys(np,400)0 and nonuset>0 ) equivx nUSET/uset1/always $ endif $

Known Error

CR 1-17889901

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Elements - CWSEAM - TABPRT, conflicts in GEOM2 NDDL descriptions

Description

The format of the CWSEAM entry is changed after MODGM2 module. This results in conflicts in NDDL descriptions for this element type and the TABPRT contents of GEOM2 data block won't match the labels.

Known Error

CR 1-17907360

Product

MSC / MD Nastran

Corrected Version 2005.1 Abstract

Rigid Elements - RIGID(LAGRAN) - Lagrange RBE2 with TEMPD and TEMP and alpha produces SFM 3003 Lagrange RBE2 with TEMPD and TEMP causes the following error.

Description

*** SYSTEM FATAL MESSAGE 3003 (SSG1) ATTEMPT TO READ PAST THE END OF A LOGICAL RECORD IN DATA BLOCK ETT (FILE 107) IN SUBROUTINE GETEMP

Known Error

CR 1-17976601

Product

MSC / MD Nastran

Known Error

CR 1-17976601

Corrected Version 2005.0.2 Abstract

Documentation/QRG - MCFRACTION

Description

Remark 7 of the Quick Reference Guide description of the MCFRACTION case control command states that the filter applies to the sorting KEY item. However, this is incorrect. The filter is always applied to the RESPONSE magnitude, regardless of which item has been used to produce the sorted listing. -

Known Error

CR 1-18016846

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

Frequency Response - SDAMPING, TABDMP1, GKAM - Poor Message, SFM 3001 If a SDAMPING request is made in the case control but no TABDMP1 entry is supplied in the bulk data, the analysis will fail in the GKAM module and the following message will be issued: *** SYSTEM FATAL MESSAGE 3001 (GKAM) THE INPUT DATA BLOCK NAMED DIT AT POSITION 5 DOES NOT EXIST.

Known Error

CR 1-18048305

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Installation/Documentation - buildsss.bat missing in V2004 The Version 2004 delivery is missing \msc\msc2004\nast\del\buildsss.bat

Description

Avoidance: Copy the attachment buildsss.bat.del to \nast\del\buildsss.bat. The IOG Documentation indicates: "msc2004 buildsss src=." However, for Windows, the "src=" is an improper format. The correct format for Windows should be: msc2004 buildsss full_path_of_source

Known Error

CR 1-18070913

Product

MSC / MD Nastran

Corrected Version 2005.5 Abstract

Documentation/QRG - MAXMIN(def), QUAD4, TRIA3, Corner Stresses Missing Documentation

Description

The MAXMIN(DEF) for corner stresses of a CQUAD4 or CTRIA3 requires the element specifation to be CQUAD4C or CTRIA3C.

Known Error

CR 1-18076410

Known Error

CR 1-18076410

Product

MSC / MD Nastran

Corrected Version GL Abstract

Heat Transfer - CTETRA - Fails to Converge Nonlinear heat transfer models with CTETRA 10 elements may fail to converge.

Description

Avoidance: Do not use the CTETRA 10 noded element in nonlinear heat transfer. Use the 12 noded CTETRA or the CHEXA element. This is a limitation using SOL 159 for CTETRA 10 element for phase change thermal analysis. Avoidance: Using the SOL 400 for phase change thermal analysis

Known Error

CR 1-18089601

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Description

Optimization/Design Sensitivity - PCOMP Zero sensitivity coffecients for composites A composite optimization job may produce zero sensitivity coefficients if the following conditions are met: 1) two or more material properties are being designed, 2) one of the designed material properties is referenced by the PCOMP entry. Avoidance: Design a material property either being referenced by a PCOMP entry or by other property types, not both.

Known Error

CR 1-18108004

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Superelements - SPARSEDR, SPCD - Wrong Answers When SPCD enforced motion is employed in an environment that involves part superelements or traditional superelements, data recovery in the superelements gives wrong results for the interior points of upstream superlements.

Description Please see the following three test decks in /nast/app/etl: q1-18108004a.dat -- Test deck employing part SEs q1-18108004b.dat -- Test deck employing traditional SEs q1-18108004c.dat -- Test deck employing single SE

Known Error

CR 1-18108004

Avoidance: Two possible avoidances exist. Either turn off sparse data recovery by setting: param,sparsedr,no or apply the following dmap alter. compile spdr1 alter 'call xAdd5 vscg0,vmcg,vadr,z01dr0,vyg' add5 v01z,vupse,,,/zzz $ equivx zzz/v01z/-1 $ endalter $ Known Error

CR 1-18126001

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Data Recovery - SORT2 in static and transient analysis - Excessive disk space usage IIn static and transient analysis when SORT2 or XYPLOT output is requested an unnecessary SDR3 operation occurs. On large problems this can require large amounts of disk space. Avoidance: Insert the following DMAP alter:

Description

compile sedrcvr alter 'strsort' if ( not sort2mm ) sdr3 oes2s,,,,,/oes1x1,,,,, $ alter 'strsort'(,1) if ( not sort2mm ) equivx oes1x/oes1x1/-1 $ alter 'sdr3 oes2s,,,,,',''

Known Error

CR 1-18136004

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Description

Data Recovery - MAXMIN(DEF) two item codes - Wrong Answers The following format of the maxmin(def) commands cause incorrect data recovery. The RMS for the second item code was zero. Also, the Z2 von mises stress was wrong for Z2. MAXMIN(DEF) STRESS QUAD4 9 MAXALG(1) RMS

Known Error

CR 1-18136004 MAXMIN(DEF) STRESS QUAD4 17 MAXALG(1) RMS Avoidance: Combine the items requested on one command, as shown below. MAXMIN(DEF) STRESS QUAD4 9 17 MAXALG(1) RMS

Known Error

CR 1-18137202

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Aeroelastic Analysis - AECOMP, MONPNT1 - Missing Monitor Point Output

Description

No Error message is issued when the COMP field on the MONPNT1 entry points to a nonexistent AECOMP entry. Instead, the MONPNT1 entry is just ignored and no output is generated for it.

Known Error

CR 1-18154902

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Frequency Response - Multiple FREQ subcases and scr=no - UFM 1126 When using scr=no with multiple frequency subcases with one of the subcase having the same DLOAD and FREQ request as a prior subcase the run will fail with:

Description

*** USER FATAL MESSAGE 1126 (GNFIST) DMAP MODULE FRLG IS ATTEMPTING TO OUTPUT DATABLOCK 201 NAME = PPF , WHICH ALREADY EXISTS. USER ACTION: DELETE THE DATABLOCK, OR USE FILE PPF=OVRWRT *** USER FATAL MESSAGE 1126 (GNFIST) DMAP MODULE FRLG IS ATTEMPTING TO OUTPUT DATABLOCK 204 NAME> > = FOL , WHICH ALREADY EXISTS. USER ACTION: DELETE THE DATABLOCK, OR USE FILE FOL=OVRWRT Avoidance: Insert the following DMAP alter: compile semfreq alter 'IF ( NOT NOPH2 and extdr','' dbstatus uhf//s,n,nouhf $ IF ( nouhf0 ) MPYAD mug1,uls1,mug1o/iugx $ alter 'MPYAD.*mef1,uls1','' MPYAD mef1,uls1,mef1o/iefx $ alter 'MPYAD.*mes1,uls1',''

Known Error

CR 1-18182101 MPYAD mes1,uls1,mes1o/iesx $ alter 'MPYAD.*mqg1,uls1','' MPYAD mqg1,uls1,mqg1o/iqgx $ compile extotmin alter 1,1 subdmap extotmin maps,dmis,dmindxs,uset,eqexins, xsop2dir,matpools/ tug1,mug1,tqg1,mqg1,tes1,mes1,tef1,mef1,rga,ugo, mug1o,mqg1o,mes1o,mef1o/ statics $ alter 'dbview' dbview x_mugo=extdb where (seid=temp and xname='mug1o' and wildcard) dbview x_meso=extdb where (seid=temp and xname='mes1o' and wildcard) dbview x_mefo=extdb where (seid=temp and xname='mef1o' and wildcard) dbview x_mqgo=extdb where (seid=temp and xname='mqg1o' and wildcard) alter 'if ( xname=','' if ( xname='matrga' or xname='tug1' or xname='mug1' or xname='tes1' or xname='mes1' or xname='tef1' or xname='mef1' or xname='tqg1' or xname='mqg1' or xname='mug1o' or xname='mes1o' or xname='mef1o' or xname='mqg1o' ) then $ alter 'equivx.*x\_tqg',''(,3) if ( statics ) then $ equivx x_mugo/mug1o/-1 $ equivx x_meso/mes1o/-1 $ equivx x_mefo/mef1o/-1 $ equivx x_mqgo/mqg1o/-1 $ endif $ statics else $ dmiin dmis,dmindxs/mug1,mes1,mef1,mqg1,,,,,, $ if ( statics ) dmiin dmis,dmindxs/mug1o,mes1o,mef1o,mqg1o,,,,,, $ matmod tug1,,,,,/tug1x,/32/1 $ equivx tug1x/tug1/-1 $ matmod tef1,,,,,/tef1x,/32/1 $ equivx tef1x/tef1/-1 $ matmod tes1,,,,,/tes1x,/32/1 $ equivx tes1x/tes1/-1 $ matmod tqg1,,,,,/tqg1x,/32/1 $ equivx tqg1x/tqg1/-1 $ mtrxin ,,matpools,eqexins,,/vax,,,,/lusets $ merge ,,,mug1,,vax,/mug1x/1 $ equivx mug1x/mug1/-1 $ merge ,,,mef1,,vax,/mef1x/1 $

Known Error

CR 1-18182101 equivx mef1x/mef1/-1 $ merge ,,,mes1,,vax,/mes1x/1 $ equivx mes1x/mes1/-1 $ merge ,,,mqg1,,vax,/mqg1x/1 $ equivx mqg1x/mqg1/-1 $ compile extout alter 'SDR2.*CASEs' dbstatus uoo//s,n,nouoo $ if ( nouoo>0 ) then $ umerge uset,uoo,/ugo/'g'/'o' $ dbstatus v01s//s,n,nov01s $ if ( nov01s>0 ) then $ Partn ugo,,v01s/,ugo1,,/0 $ delete /ugo,,,, $ merge ,,ugo1,,,,v01s/ugo/0 $ endif $ nov01s>0 SDR2 CASEs,CSTMS,MPTS,DIT,EQEXINS,,ETT,nulllama,BGPDTS,,qg, ugo,EST,XYCDBs,,,,,,,,,,,,,,/ ,iqg1o,IUG1o,IES1o,IEF1o,,,,,,,/ 'reig'/S,N,NOS2A/S,N,NCOMPS $ DRMH1 Iug1o,Iqg1o,Ies1o,Ief1o/ TUG1o,MUG1xo,TQG1o,MQG1xo,TES1o,MES1xo,TEF1o,MEF1xo/ /1/7/3/1005/1004 $ add5 mug1xo,,,,/mug1o $ add5 mqg1xo,,,,/mqg1o $ add5 mes1xo,,,,/mes1o $ add5 mef1xo,,,,/mef1o $ endif $ nouoo>0 alter 'EQUIVX mug1\/EXTDB' xname = 'mug1o' $ EQUIVX mug1o/EXTDB/-1 $ alter '15.*\'mug1' append ,,/xsop2dir/15///////'mug1o' $ alter 'EQUIVX mqg1\/EXTDB' xname = 'mqg1o' $ equivx mqg1o/extdb/-1 $ alter '15.*\'mqg1' append ,,/xsop2dir/15///////'mqg1o' $ alter 'EQUIVX mes1\/EXTDB' xname = 'mes1o' $ equivx mes1o/extdb/-1 $ alter '15.*\'mes1' append ,,/xsop2dir/15///////'mes1o' $ alter 'EQUIVX mef1\/EXTDB' xname = 'mef1o' $ equivx mef1o/extdb/-1 $

Known Error

CR 1-18182101 alter '15.*\'mef1' append ,,/xsop2dir/15///////'mef1o' $ alter 'matpch mug1' matpch mug1o,mqg1o,mes1o,mef1o/ $ alter 'xname=\'mug1\''(,2) xname='mug1o' $ dbstatus extdb//s,n,noextdb $ if ( noextdb>0 ) output2 extdb//0/outunit///'matrix' $ alter 'xname=\'mqg1\''(,2) xname='mqg1o' $ dbstatus extdb//s,n,noextdb $ if ( noextdb>0 ) output2 extdb//0/outunit///'matrix' $ alter 'xname=\'mes1\''(,2) xname='mes1o' $ dbstatus extdb//s,n,noextdb $ if ( noextdb>0 ) output2 extdb//0/outunit///'matrix' $ alter 'xname=\'mef1\''(,2) xname='mef1o' $ dbstatus extdb//s,n,noextdb $ if ( noextdb>0 ) output2 extdb//0/outunit///'matrix' $ endalter

Known Error

CR 1-18187316

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Description

Elements - CBUSH, PBUSH and PBUSHT (KN) wrong answers In Version 2004, if K1 is left to be blank on the PBUSH or PBUSHT entries, the default value should be zero; however, an error in ifp may results in unexpected values being used resulting in wrong answers.. Avoidance: If a zero stiffness is desired, explicitly specify 0.0, do not leave the k1 field blank.

Known Error

CR 1-18192403

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Description

Matrix Methods - Complex Unsymmetric Decomp , SYSTEM(221) - Wrong Answers MSC.Nastran HPUX systems are the only ones that set the rank of update for complex unsymmetric sparse decomp to greater than 1. This can lead to wrong answers. Avoidance: On HP system set system(221)=1 in the nastran rc file. On

Known Error

CR 1-18192403 all other systems do not set this system cell.

Known Error

CR 1-18215901

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Description

Temperature Loads - CHEXA - Non uniform temperature on HEXA element UFM 4661 HEXA models with constant material values defined on the MATT1 entry may fail to converge even though the same models converge when the MATT1 entry is removed or a constant temperature is applied. Other elements have not demonstrated this behavior. Avoidance: If there is no temperature depencency, remove the MATT1 entry.

Known Error

CR 1-18217901

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Dynamic Response - RESTARTS, SPCD - UFM 5423 Dynamic response restart jobs (SOL 108, 109, 111, and 112) may not handle enforced motion correctly. This may result in wrong answers in V2001 and V2004, but causes termination of the job with UFM 5423 in the FRLG module in V2005.

Avoidance: Two avoidance schemes exist. ------------1. Use a dummy (unused) FORCE or DAREA Bulk Data entry in the restart job. Description 2. Employ the following DMAP alter in the restart job: compile semfreq $ for sol 111 (use sedfreq for sol 108, sedtran for sol109 and semtran for sol112) alter 'dpd '(,-1) $ paraml yg//'trailer'/1/s,n,ygcols $ paraml pg//'trailer'/1/s,n,pgcols $ type parm,,i,n,extracol $ extracol = ygcols - pgcols $ $ append extracol null columns to pg append pg,/pgnew/1//extracol $

Known Error

CR 1-18217901 delete /pg,,,, $ equivx pgnew/pg/-1 $

Known Error

CR 1-18228729

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Miscellaneous - Unicode text causes UFM 300 If a file is saved as unicode text, the nastran job may fail with the following message

Description

*** USER FATAL MESSAGE 300 (RCARD) DATA ERROR IN FIELD UNDERLINED. EMBEDDED BLANK. If you look at the file in Nodepad, it appears to look ok. However, if you look at it in a vi editor, you will see blanks between each character Avoidance: Save the file in standard text format

Known Error

CR 1-18235402

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

CWELD Elements - Wrong Bearing Stresses for CWELD elements The bearing stress should equal the resultant of the shear forces divided by the (cweld diameter x minimum thickness of the connected shell elements).

Description

However, the dependency on the minimum thickness TMIN is broken and the output for the bearing stress is equal to simply the Shear Force divided by the Weld Diameter. This error has been verified by the initiator.

Known Error

CR 1-18239502

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Size Limitation - Maximum of 120 DMI matrices and DTI tables are allowed

Description

A maximum of 120 unique DMI matrices and 120 tables are allowed in the input. In Version 2001 an attempt was made to increase the limit to 1000 but the change was incomplete.

Known Error

CR 1-18291503

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Superelements - EXTSEOUT - SFM 3002 (Logic Error 29) in the BDRYINFO module. Double field GRID entries for interior points of exterior superlements may result in: *** SYSTEM FATAL MESSAGE 3200 (BDYINP) LOGIC ERROR 29 ENCOUNTERED IN SUBROUTINE BDYINP USER ACTION: REPORT THIS PROBLEM TO MSC CLIENT SUPPORT

Description

in the BDRYINFO module. Avoidance: Use single field GRID entries or double field GRID entries with the grid IDs in columns 9-16 Alternatively, as indicated above, first get the Bulk Data deck punched out by Nastran and then use this punched deck as input. This will cause the GRID IDs in the double field entries to be left justified (in columns 9-16).

Known Error

CR 1-18300703

Product

MSC / MD Nastran

Corrected Version 2010.1.2 Abstract

Elements - Different Warping Coefficients for PBEAML with BOX and BOX1 Cross Section

Description

The BOX and BOX1 cross sections of the MSCBML0 group yield inconsistent warping coefficients for the same cross section. The BOX cross section yields a 0.0 value for the warping coefficient while the BOX1 will be nonzero. To include warping included, use the BOX1 cross section. The problem is also present in Patran and its Beam Library so ensure that the fix gets to both programs.

Known Error

CR 1-18300741

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Modal Transient Analysis - TIC - UFM 2133 (DPD) In SOL 112, when a degree of freedom is specified on a TIC entry that is not in the a-set the job will fail appropriately with the message:

Description

USER FATAL MESSAGE 2133 (DPD) *** USER FATAL MESSAGE 2133 (DPD) INITIAL CONDITION IN SET 1 SPECIFIED FOR POINT NOT IN ANALYSIS

Known Error

CR 1-18300741 SET. However, the message does NOT indicate the grid and component. When a large number of TIC are present in the input file it is difficult to identify the problem input.

Known Error

CR 1-18419669

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Postprocessing - MPC data in GEOM4 datablock created by module MAKEOLD is not in single precision If the model contains MPC entries, and the MAKEOLD module is used to convert the MPC entries in the GEOM4 datablock to single precision, the conversion does not take place. This happens for instance when PARAM,POST,-1 or -2 are requested and PARAM,OGEOM,YES (default) is used. The error was reported because IDEAS was terminating when reading an op2 file created using PARAM,POST,-2. In addition to being corrected in the 2005r2 release, this error was corrected in a special build of 2004.5.1 on AIX, IRIX, and Sunos only. This system was not written to cd and is only availalbe from MSC's internal ESD site.

Description

Avoidance: Insert the following DMAP alter for 2004.5. This alter wil create an op2 file compatible with V2001 when either PARAM,POST,-1 or -2 is specified and NASTRAN OP2NEW=0. The alter deletes the erroneous MPC data from the GEOM4 datablock so it does not get written to the op2 file. An alter is also available that converts the double precision MPC data to single precision using the table insert functions of the PARAML module to create a single precision MPC data record which is then added to the GEOM4 datablock after MAKEOLD processing. NASTRAN OP2NEW=0 ECHOOFF $ $ V2004.5 op2 in 2001 format, post -1 and post -2 $ COMPILE OUT2GEOM NOLIST $ ALTER 'MAKEOLD GEOM4','' $ TYPE PARM,,I,N,RECNUM=1 $ $ $ remove MPC entries from GEOM4 DO WHILE (RECNUM>0) $

Known Error

CR 1-18419669 PARAML GEOM4//'DTI'/S,N,RECNUM,/1//S,N,ID1 $ PARAML GEOM4//'DTI'/S,N,RECNUM,/2//S,N,ID2 $ EQUIVX GEOM4/GEOM4Z/RECNUM $ IF (ID1=4901 AND ID2=49) THEN $ PARAML GEOM4/GEOM4Z/'TABDEL'/RECNUM/0 $ RECNUM=-1 $ ELSE $( RECNUM=4901 AND ID2=49) RECNUM=RECNUM+1 $ ENDIF $ (RECNUM=4901 AND ID2=49) ENDDO $ (RECNUM>0) MAKEOLD GEOM4Z,GEOM3,,,/GEOM4X,GEOM3X,,,/ 'GEOM4'/'GEOM3'////'GEOM4'/'GEOM3' $ $ $ for post -2 $ ALTER 'OUTPUT2 CSTMX' $ TYPE PARM,,I,N,NP $ IF (GETSYS(NP,403)=0) THEN $ MATMOD GEOM2X,,,,,/IGEOM2X,/13 $ matprn geom4,geom4x // $ $ OUTPUT2 IGEOM2X,GEOM3X,GEOM4X,GEOM1X,BGPDTX//0/OUNIT1//OMAXR/ $ 'GEOM2'/'GEOM3'/ GEOM4 / GEOM1 / BGPDT / $ 'GEOM2'/'GEOM3'/'GEOM4'/'GEOM1'/'BGPDT' $ OUTPUT2 IGEOM2X,GEOM3X,GEOM1X,BGPDTX//0/OUNIT1//OMAXR/ 'GEOM2'/'GEOM3'/ GEOM1 / BGPDT / 'GEOM2'/'GEOM3'/'GEOM1'/'BGPDT' $ ELSE $ ALTER 'OUTPUT2 GEOM2X' $ ENDIF $ $ $ for post -1 $ ALTER 'ELSE IF ( POST=-1' $ IF (GETSYS(NP,403)=0) THEN $ MATMOD GEOM2X,,,,,/IGEOM2X,/13 $ OUTPUT2 GEOM1X,IGEOM2X,GEOM3X,GEOM4X,EPTX//OTAPE2/OUNIT1//OMAXR/ GEOM1 / GEOM2 / GEOM3 / GEOM4 / EPT / 'GEOM1S'/'GEOM2S'/'GEOM3S'/'GEOM4S'/'EPTS' $ OUTPUT2 MPT,DIT,DYNAMICS//0/OUNIT1//OMAXR $ IF ( POSTEXT='YES' ) OUTPUT2 BGPDTX//0/OUNIT1//OMAXR/BGPDT/////'BGPDTS' $ ELSE $ ALTER 'OUTPUT2 BGPDTX' $

Known Error

CR 1-18419669 ENDIF $ ENDALTER $ ECHOON $

Known Error

CR 1-18435641

Product

MSC / MD Nastran

Corrected Version Abstract

SOL 600/installation - Long Installation Paths - ** Severe Marc Translator Warning ** For SOL 600, long path names for the location of the marc executable will cause a failure on Windows. The default installation paths for MSC.Nastran V2005 are longer and thus this problem is exacerbated.

Descriptio n ** Severe Marc Translator Warning ** Script to run Marc not in expected directory \\benelux1\applic\windows\msc.software\msc.nastran\2005\msc2005\marc\tools\ run_m Known Error

CR 1-18450701

Product

MSC / MD Nastran

Corrected Version 2005.1 Abstract

Description

Nonlinear Analysis - CBAR, CBEAM with offsets and param,lgdisp fails with UFM 6174 USER FATAL MESSAGE 6174 is incorrectly issued when a nonlinear model contains bar or beam elements with offsets and param,lgdisp,-1. When param,lgdisp,1 is specified the differential stiffness is not required, thus the fatal should not be issued. Avoidance: There is no avoidance.

Known Error

CR 1-18482126

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Optimization/Design Sensitivity - DESVAR - SFM 3001 (DOPR4) indicating DTOS2J does not exist

Description

An optimization job that has a DESVAR Case Control command that only activates shape variables but both sizing and shape variables are present, may fail in DOPR4 with SYSTEM FATAL MESSAGE 3001 indicating that DTOS2J does not

Known Error

CR 1-18482126 exist. Avoidance: Apply the following dmap alter: compile predom list alter 'dopr1' type parm,,i,n,protyp $ protyp = 0

Known Error

CR 1-18491202

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Documentation/QRG - MCFRACTION - Wrong Description of Item SCALED

Description

Under the QRG description of the MCFRACTION Case Control Command, SCALED should be described as the " PROJECTION DIVIDED BY THE LARGEST MAGNITUDE OF MODAL RESPONSE".

Known Error

CR 1-18491296

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Description

MCFRACTION - Incorrect description of "SCALED RESPONSE MAGNITUDE" in the f06 Description of the "SCALED RESPONSE MAGNITUDE" under the MODAL CONTRIBUTION FACTORS output in the f06 is not correct. It should read: PROJECTION MAGNITUDE DIVIDED BY THE LARGEST MAGNITUDE OF THE MODAL RESPONSE.

Known Error

CR 1-18501346

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Description

Dynamic Analysis - MEFFMASS fails if the a-set is comprised entirely of q-set The modal effective mass calculation (MEFFMASS Case Control command) will terminate with the following message if the a-set is comprised entirely of q-set. SYSTEM FATAL MESSAGE 3007 (3007) ILLEGAL INPUT TO SUBROUTINE MPYAD

Known Error

CR 1-18501346 In GDACMS (domainsolver acms) and PARAM,AUTOQSET,YES, it is typically the case that the a-set of the residual structure is comprised entirely of q-set. This condition can also occur with component mode analysis. Avoidance: 1. For non-GDACMS problems, insert some physical degrees-of-freedom on the ASETi entries. 2. For GDACMS problems or PARAM,AUTOQSET,YES problems, either switch to MDACMS (domainsolver acms (partopt=dof)) or insert the following DMAP alter: compile augqset alter 'usetq'(2) type parm,,logi,n,npl $ moduset ,,usetq/usetz/'move'/'l'/'o' $ equivx usetz/usetq/-1 $ compile phase0 alter ' gp4 '(,-1) if ( seid=0 ) atqset=false $ endalter If you are running PARAM,AUTOQSET,NO with GDACMS then insert SENQSET,0,0 in the Bulk Data section.

Known Error

CR 1-18504349

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Description

Online Documentation - V2005 Index is labelled as "MSC.Nastran 2004" The "start point" for the MSC.Nastran v2005 documentation on the Online Documentation cd is labled "MSC.Nastran 2004 Books". The links for the Installation & Operations Guide, QRG, and Release Guide DO bring up the v2005 documentation. The link to the DMAP Guide is missing. New graphic pages without the year are to be used for future releases.

Known Error

CR 1-18511311

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

MDACMS - MCFRACTION - Wrong Answers for MFRACTION with MDACMS

Known Error

CR 1-18511311 If MCFRAC is requested with MDACMS (DOMAINSOLVER ACMS(PARTOPT=DOF)) then wrong answers may result in the MCFRAC output. Avoidance: There are 2 possible avoidances: 1. Specify an additional output request, like DISP, for the same points specified on the MCFRAC command. 2. Insert the following DMAP alter:

Description

compile semfreq alter 'call fdrmgen','' if ( sparseph='yes' and mdacms ) CALL FDRMGEN, USET,VGFD,CASERS,USETD,GM,GOt,goq,, MSF,,,,BSF,,,,KSF,K4SF,,,,asf,adsf, MMG,,BMG,,KMG,K4MG,,KDMG,KDSF,, MSS,,BSS,,KSS,K4Ss,,kdss,yg, ects,bgpdts,sils,xycdb,matpool,pg,dynamics,casecc, slist,emap,maps,,,,,mmcdb,oint,pelsets, pmyg,pbyg,pkyg,ajp,,nzyg,/ ,,,,,,, MSF1,BSF1,KSF1,mss1,bss1,kss1,MMG1,BMG1,KMG1,,,, vspcg,vmpcg,v01p,v01dr,vpg,vgdr,vmcfg,,,/ APP/APP/SOLTYP/FALSE/false/NOOSET/NOA/NOMSET/ S,DOMPCF/S,DOSPCF/NOSSET/NOUE/S,DOMPCFFD/ S,DOSPCFFD/FALSE/FALSE/rsonly/' '/ s,spdrs/s,spdrm/pexist/false/s,spdr/adptindx/true $ type parm,nddl,logi,n,seindr $ seindr=true $ add5 vpg,vmcfg,v01p/vxx $ equivx vxx/v01p/-1 $ endalter

Known Error

CR 1-18516872

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Description

Submittal - mem=2800mb on NEC SX-6(SUPER-UX 13.1), SFM7620 occurs. MSC.Nastran 2004.0.6 (2004r2) and 2005.0.0 (2005 R1) on Nec SX-6 computers may fail with the fatal message shown below when a large memory request (mem=2800mb) is made. This error has been corrected in 2005.0.1 delivered on the 2005R1a cd. *** SYSTEM FATAL MESSAGE 7620 (GP3D) Dynamic memory block has incorrect checksum

Known Error

CR 1-18527891

Known Error

CR 1-18527891

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Description

MDACMS - DMP, NUMDOM - K-PARTITIONING FAILED, Possble Wrong Answers If the user specifies a relatively large value for the number of domains, numdom, for a small problem in mdacms, the partitioner may fail and in rare cases produce wrong answers. When failure does happen the only message is "K-PARTIONING FAILED". Nevertheless MDACMS continues. Avoidance: Do no specify high values of numdom for small problems. Do not deviate significantly from the defaults.

Known Error

CR 1-18540430

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Documentation - V2005 online CD may not read properly on some CDs Cannont Copy basic functions The CD has been remanufactured and an installation has been added to eliminate the cyclic redundency error. Please test out the new CD. ----------------------------------------------------------------------------------------------------------------------------------------------------------------------

Description

It has been observed that the 2005 combined documentation CD may not load properly on some CD drives. The following error will occur in this case: Cannot copy basic_functions: Data Error (cyclic redundancy check) Avoidance: If available, use another CD drive.

Known Error

CR 1-18561858

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Documentation/QRG - CELAS - Coincident Points The following remark will be added under the celasi QRG description.

Description

It is recommend that for most applications that the grids connected by celas entries be coincident and the displacement coordinate systems of each grid be congruent. Connecting non-coincident grids and/or noncongruent coordinate systems can lead to models that do not pass strain energy checks (see GROUNDCHECK case control).

Known Error

CR 1-18562191

Product

MSC / MD Nastran

Corrected Version 2005.1 Abstract

External Superelements - EXTSEOUT, DMIGPCH - Extra Output An EXTSEOUT SE creation run may output the stiffness matrix even though the EXTSEOUT command explicitly requested only the LOADS to be DMIGPCH.

Description Avoidance: Apply the alter avoidance scheme given under the description of error number 1-18908795. Known Error

CR 1-18569569

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Description

Model Checkout/Superelements - RBE3, PARAM,CHECKOUT,YES - Bad diagnostics with SELOC PARAM,CHECKOUT,YES may give bad diagnostic information when SELOC is present. The bad diagnostics is for the EMH matrix which is an equilibrium check on MPCs and constraint elements. The bad diagnostics will indicate a modeling error when no error exists. . Avoidance: Use another checking procedure, such as applying SPCDs in static analysis that should move the structure as a rigid body. If the MPCs and constraint elements pass this test they meet the equilibrium requirement.

Known Error

CR 1-18570326

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Elements - CWELD - Missing UFM 7549 (SEPWLD)

Description

Impropely defined cweld elements where the projection onto the surface cannot be found may not be trapped and the job may fail unexpectedly. Avoidance: There is no avoidance.

Known Error

CR 1-18573051

Product

MSC / MD Nastran

Corrected Version 2005.5 Abstract

Rotor Dynamics - NLRGAP - Wrong Answers, null unbalanced load output

Description

If an NLRGAP entry is used in a rotor dynamics analysis (SOL129), then

Known Error

CR 1-18573051 the unbalanced force that is output with the NLLOAD command is equal to zero.

Known Error

CR 1-18589051

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Description

Optimization/Design Sensitivity - DRESP2 with BETAMATCH referenced by DESSUB - SFM 3001 When an optimization job with BETA/MATCH DRESP2 response, it may fail in DOPR1 with SFM 3001 when the response is referenced by a DESSUB command. Avoidance: Remove the offending DESSUB entry.

Known Error

CR 1-18602293

Product

MSC / MD Nastran

Corrected Version 2005.5 Abstract

Eigenvalue Analysis - EIGRL - USER FATAL MESSAGE 4405 (PRTPRN)

Description

For most real world problems the CRAY X1 Unicos system's acrhitecture is such that it realizes a performance gain when MAXSET on the EIGRL entry is set to 12 rather than to default value of 7 used on most other machines. One small test problem (s6821) diverged when trying to solve the eigenvalue problem. This small test completes when MAXSET is changed to 7.

Known Error

CR 1-18612550

Product

MSC / MD Nastran

Corrected Version Abstract

Description

Nonlinear Transient Analysis - TSTEPNL - UFM 5423, TSTEPNL with NO = 2 In SOL 129, the enforce motion with large mass job may fail with the following message ==================================== *** USER FATAL MESSAGE 5423 (SADD5) ATTEMPT TO ADD INCOMPATIBLE MATRICES, (SADD5) ==================================== It happens when (1) all results are null, and (2) NO > 1 and there is no reminder of (NDT/NO) on TSTEPNL. [Avoidance]: (1) Do not produce a null results, or (2) Set NO=1 or make (NDT/NO) have reminder on TSTEPNL.

Known Error

CR 1-18622044

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Topology Optimization - TOPVAR, PWELD - Poor Message

Description

MSC.Nastran 2005 topology optimization does not have a good fatal error message if the PID entry referenced on a TOPVAE entry does not exist.

Known Error

CR 1-18625541

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Description

Postprocessing - param,post - UIM 4114 when writing large data blocks written to op2 file When writing data blocks larger than 1GW to an op2 file in binary format, the UIM 4114 data fields will overflow, causing '*********' to be put in the messages. The correction is to accumulate the values in INTEGER*8 variables and to change the format statements to I12. This will allow data blocks up to 1TW to be written to the op2 files without any UIM 4114 data field overflow. For binary mode OP2 files, this was fixed as part of the code turned in to fix quality number 1-18605381. For the time being, other possible error locations have not been fixed because it has been determined that the possibility of the error occurring is very low.

Known Error

CR 1-18635621

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Mass - NSM1 and NSML1 have alternate forms which do not allow continuation - Missing Fatal Message

Description

Tthe alternate forms of the nsm1 and nsml1 entries were designed and documented not to allow for continuation entries. If the user does have a continuation entry, the entire entry is processed as the basic form with a single ID.

Known Error

CR 1-18636381

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Optimization/Design Sensitivity - Problems when a designed property is zero in SOL 200

Description

The design optimization capability in SOL 200 of MSC.Nastran applies move

Known Error

CR 1-18636381 limits to the properties when solving the approximate optmization problem. If the baseline property is 0.0, the move limits can be very small with the result that a small movement in the design variables will result in a violated constraint. Avoidance: Avoid starting designs that result in a zero property value. Examples are the design of an I12 term in a beam starting from a cross setcion that has a plane of symmetry or the warping coefficents in a PBEAML with a box section type that is square.

Known Error

CR 1-18640031

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Description

Eigenvalue Analysis - EIGRL, MAXSET - Nan values in Eigenvalue Table on Nec SX6 For most real world problems the NEC SX6 system's architecture is such that it realizes a performance gain when MAXSET on the EIGRL entry is set to 15 rather than the default value of 7 used on most other machines. For small problems, nastran will automatically lower the MAXSET value. One small test problem has been found that contained two static subcases (STATSUB) followed by two eigenvalue analysis where the value was lowered to 8 and it should have been lowered to 7. This resulted in Nan's being printed in the Eigenvalue summary table. Avoidance: If this problem is encountered, manually set the MAXSET value to one lower than what is reported for "BLOCK SIZE USED". Solving the eigenvalues for the two sucases in separate runs also avoided the problem. This problem has been corrected in 2005.0.1 delivered on the 2005 R1a cd.

Known Error

CR 1-18642547

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Cyclic Frequency Response - SOL 118, RESTART - Output Labled as Real instead of Complex on Nec SX6 A restart of SOL 118, Cyclic Direct Frequency Response in Version 2005 on Nec SX6, may result in output being labled as Real instead of Complex.

Description Avoidance: Run the job as a cold start. This error is fixed in Versin 2005.0.1 delivered on the 2005 R1a cd. Known Error

CR 1-18642630

Product

MSC / MD Nastran

Known Error

CR 1-18642630

Corrected Version 2005 Abstract

Superelement Component Mode Synthesis - PARAM,METHDCRMS - UWM 8592 (REIG), V2005 Nec SX6 Only If param,methcrms is specified in a superelement eigenvalue analysis on V2005 Nec SX6, then the job may fail with the message:

Description

*** USER WARNING MESSAGE 8592 (REIG) THE METHOD RECORD IN CASE CONTROL IS MISSING OR INCORRECT. THIS WILL CAUSE THE FOLLOWING FATAL ERRORS. USER ACTION: PUT A METHOD ENTRY IN CASE CONTROL WHICH POINTS TO AN EIGR, EIGRL, OR EIGB RECORD IN BULK DATA. *** USER FATAL MESSAGE 3032 (READ) UNABLE TO FIND SELECTED SET ( 2000) IN TABLE (EED ) IN SUBROUTINE (REIG). Avoidance: Other than not specifying this parameter, there is no avoidance.

Known Error

CR 1-18642659

Product

MSC / MD Nastran

Corrected Version 2005 Abstract

Miscellaneous - mem= = - SFM 7620 (GP3D) on Nec SX6 If a mem= is specified to be greater than 2800mb on MSC.Nastran 2004r2 or 2005 on Nec SX 6 the job may fail with the message:

Description

*** SYSTEM FATAL MESSAGE 7620 (GP3D) Dynamic memory block has incorrect checksum Avoidance: Make a smaller memory request

Known Error

CR 1-18643741

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Superelements - Multi-MASTER method, Shell Normals (SNORM) - Wrong Answers Shell normals computed in the "SEMAP" run are not being saved for the subsequent restart run and this may lead to poor answers.

Description

Avoidance: Insert the following DMAP alter in all runs: compile phase0 alter 1 type db gpsnt $

Known Error

CR 1-18643741 endalter

Known Error

CR 1-18673881

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

An Analytic Boundary Shape optimization job fails with UFM2011 in TA1although PBAR is defined In v2001, when an Analytic Boundary Shape optimization job also includes the sizing variables so that the designed model value overrides the analysis model property, the job may fail in TA1 with UFM2011 complaining missing PBAR entry although it is defined.

Description

Avoidance: 1) ensure all the design model properties are identical to those analysis model values or 2) use the following DMAP alter: compile desopt list alter 'PARAML OPTPRMG'(1,-1) DBEQUIV DATABLK=(ept,mpt), WHERE (DESITER=0 AND AUXMID > 0 AND WILDCARD) CONVERT (DESITER=1) , OVRWRT $

Known Error

CR 1-18678552

Product

MSC / MD Nastran

Corrected Version 2005.1 Abstract

Optimization/Design Sensitivity - Incorrect updated PBEAM entries written to the punch file

Description

In design optimization Incorrect updated PBEAM entries are written to the punch file.

Known Error

CR 1-18679258

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

Nonlinear Analysis - GPFORCE, TEMP(LOAD) - GPFORCE incorrect in nonlinear with thermal load The GPFORCE balance is incorrect in SOL 106 when there is thermal load because the themal load contribution is included twice. This is a limitation of SOL 106. Please note that the results in SOL 400 are correct. Avoidance:

Known Error

CR 1-18679258 (1) Replace "SOL 106" by "SOL 400" (2) Add "ANALYSIS=NLSTAT" in the case control deck (you really need not do it in this deck since the default of ANALYSIS is NLSTAT in SOL 400.), (3) Replace "SUBCASE" by "STEP" in the case control deck (you can also skip this change since this test deck is single SUBCASE only.).

Known Error

CR 1-18688331

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

Description

Elements - CQUAD4, TRIA3, K6ROT - Incorrect drilling stiffness for membrane only elements. In MSC.Nastran Version 2004, the default for K6ROT was changed from 0. to 100. The new default works well for most models, but membrane only elements should use a K6ROT of 0.0. Avoidance: For models created entirely of membrane only elements, set param,k6rot,0.0.

Known Error

CR 1-18691831

Product

MSC / MD Nastran

Corrected Version 2005.0.2 Abstract

ACMS - UFM 740 (RDASGN) when using PACMS with PARTOPT=GRID In MSC.Nastran Version 2004.5 (2004r3) and Version 2005 if PACMS is used with PARTOPT=GRID then the job may fail with USER FATA MESSAGE 740 (RDASGN).

Description

*** USER FATAL MESSAGE 740 (RDASGN) UNIT NUMBER 12 HAS ALREADY BEEN ASSIGNED TO THE LOGICAL NAME OP2 USER ACTION: CHANGE THE UNIT NUMBER ON THE ASSIGN STATEMENT AND IF THE UNIT IS USED FOR PARAM,POST,0 and sdrs=-1 ) then $ endalter

Known Error

CR 1-19006294

Product

MSC / MD Nastran

Corrected Version 2005.5 Abstract

Modal Transient/External Superelements - EXTSEOUT, MAXMIN - SFM 5423 The following conditons will lead to SYSTEM FATAL MESSAGE 5423 (DMPYAD), ATTEMPT TO MULTIPLY INCOMPATIBLE MATRICES:

Description

1. Modal transient response (SOL 112) 2. External superelement when external superelements are attached using the EXTSEOUT case control command. 3. MAXMIN data recovery is requested 4. DISP=n where SET n is only some of the GRID points. 5. Sparse data recovery is active (default) - PARAM,SPARSEDR,NO will deactivate

Known Error

CR 1-19006294 Avoidance: Specify PARAM,SPARSEDR,NO

Avoidance: Insert the following alter ECHOOFF $ COMPILE SEDRCVR NOLIST $ $ ALTER 'SDR3 OUG1'(,-1),'' $ IF ( NOT(SORT2MM) OR EXTERSE ) THEN $ $ ALTER 'SDR3 OUG2','' $ DBSTATUS OUG1,OVG1,OAG1,OPG1,OQG1,OQMG1// S,N,NOOUG1/S,N,NOOVG1/S,N,NOOAG1/ S,N,NOOPG1/S,N,NOOQG1/S,N,NOOQMG1 $ IF ( NOOUG10 and not(mdstat) and ( (dbrcvx='scratch' and not(pardcmp)) or (pardcmp and hlpmethx=1 and procid=1) ) ) CALL PHASE1C KAA ,USET ,SILS ,EQEXINS ,maa , PA , , ,cases , , drg , , , / KLL ,LLL ,Dar ,ULL ,mr , mlr ,mll ,mrr ,QR ,PL , LRSEQ , , , , , / SEKR /SEMR /SELR /NOLSET /NORSET / true /ERROR /FIXEDB /NOQSET /NOTSET / ' '/TRUE /false /false /noa / false $ $ for versions 2005.1.0 and 2005.0.0 compile sestatic alter 'call phase1c','' $ tested on version 2005.1.0 and 2005.0.0 IF ( nouset>0 and not(mdstat) and ( (dbrcvx='scratch' and not(pardcmp)) or (pardcmp and hlpmethx=1 and procid=1) ) ) CALL PHASE1C KAA ,USET ,SILS ,EQEXINS , , PA , , ,cases , , drg , , / KLL ,LLL ,Dar ,ULL ,mr , mlr ,mll ,mrr ,QR ,PL , LRSEQ , , , , / SEKR /SEMR /SELR /NOLSET /NORSET / true /ERROR /FIXEDB /NOQSET /NOTSET / ' '/TRUE /false /false /noa / false $ Test file place on /msc/app/etl as q1-25716447.dat

Known Error

CR 1-25721381

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract Description

DMAP - DMAP compiler issues UWM 1 instead of UFM 12 A DMAP compile may issue UWM 1 instead of UFM 12:

Known Error

CR 1-25721381 # *** USER FATAL/WARNING MESSAGE 12 (XGPIDG) ERROR IN DMAP INSTRUCTION NO. %1, ILLEGAL CHARACTER IN DMAP INSTRUCTION NAME.

Known Error

CR 1-25750061

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Description

Connector Elements - PFAST with MCID=-1 and MFLAF=1 may yield strange element coordinate system PFAST entry with MCID=-1 and MFLAG=1 may yield strange elemet coordinate system for force recovery. If MCID=-1, MFLAG should always be blank or 0. The fix will set MFLAG to if MCID=-1 regardless of value specified.

Known Error

CR 1-25759747

Product

MSC / MD Nastran

Corrected Version 2006.0.1 Abstract

GPSTRAIN - CQUADx, CTRIAx - Incorrect MAX Shear Strain

Description

MD Nastran 2006 (r1) introduced an error that causes the maximum shear strain for shell elements to be twice it should be. The error has been corrected in MD Nastran 2006 (r1a).

Known Error

CR 1-25765441

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Connector Elements - CFAST, CWELD may not find projection and may fail to connect

Description

If gridA and gridB are specified on a CFAST or CWELD and grid GS is left blank for the attached model the algorithm may be unable to project.

Known Error

CR 1-25765671

Product

MSC / MD Nastran

Corrected Version 2006 Abstract Description

Acoustic Analysis - PFPANEL - Wrong Answers 1. If Keyword "PHAS" is specified on the PFPANEL command, the real and imaginary part printed in the .f06 are wrong.

Known Error

CR 1-25765671 Avoidance: Do not specifiy "PHAS" keyword. 2. If there are panels that are not part of the wetted surface, the panel names in OAPPF1 and in the .f06 are wrong. Avoidance: Do not define panels that are not on the wetted surface.

Known Error

CR 1-25773137

Product

MSC / MD Nastran

Corrected Version Abstract

Superelements - PARAM,SESDAMP,YES does not work correctly when PARAM,AUTOQSET,YES is also specified. Attempting to apply different damping to different superelements using PARAM,SESDAMP,YES combined with PARAM,AUTOQSET,YES leads to wrong answers. This error can also occur when assembling a superelement created from EXTSEOUT(DMIGPCH). Avoidance 1: Use manual Q-set entries instead of employing PARAM,AUTOQSET,YES

Description

Avoidance 2: Employ the DMAP alter given below when using PARAM,AUTOQSET,YES compile phase1b alter 'call semrb'(9) np=noqset-xnoq $ delete /vq,,,, $ matgen ,/vq/6/noqset/xnoq/np $ matgen ,/vq1/6/noqset/np/xnoq $ partn mbqq,vq,/mbqq0,,, $ delete /mbqq,,,, $ merge ,,,,mbqq0,vq1,/mbqq $

Known Error

CR 1-25775091

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Aeroelastic Analysis - MONPNT2 - SFM 3008 (ILMP1) Insuficient entry _MONPNT2

Description

The message: SYSTEM FATAL MESSAGE 3008 (ILMP1) Insuficient entry _MONPNT2 can be produced if a MONPNT2 bulk data entry invokes an element that is connected to the highest numbered grid point in the model.

Known Error

CR 1-25775091 Avoidance: Do not select an element on a MONPNT2 that is connected to the highest numbered grid point in the model. Else renumber the grids associated with the element so that the grid is not the highest in the model.

Known Error

CR 1-25797677

Product

MSC / MD Nastran

Corrected Version 2005.5.2 Abstract

Heat Transfer - VIEW, RADSET - SFM 3002 (RMG2) When the number of cavities defined on a RADLST entry exceed the number of cavities specified on the RADSET entry the following fatal message will be issued:

Description

*** SYSTEM FATAL MESSAGE 3002 (RMG2) EOF ENCOUNTERED WHILE READING DATA BLOCK EST (FILE 101) IN SUBROUTINE RMG2 0FATAL ERROR

Known Error

CR 1-25801752

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Postprocessing - DBC, PARAM,POST,0 - SFM 6062 (DBC), Poor Message If the XDB size is exceeded the following fatal message is issued.

Description

*** SYSTEM FATAL MESSAGE 6062 (DBC) *** DIOMSG ERROR MESSAGE 6 FROM SUBROUTINE WRTLST OVERFLOW OF DICTIONARY PRIMARY INDEX FOR DATA BASE UNIT 1. This message should be improved to instruct the user to increase the default RECL for the xdb file on an ASSIGN statement.

Known Error

CR 1-25925548

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Elements - PCOMP yields Incorrect results for the BEND option

Description

When the BEND option is added to the pcomp entry, the generated mat2 entry has the Gij terms for membrane instead of the Gij terms for bending . ******************* Fixed V2007.0.0

Known Error

CR 1-25945741

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Nonlinear Analysis - EKE is not available for modal preload analysis. EKE is not available for a modal preload analysis in SOL 106.

Description Avoidance: Supply a dummy linear element Known Error

CR 1-25986051

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Superelements - SFM 3007 (BNDSPC), BNDSP3 A job with many superelements may fail with the following error message: *** SYSTEM FATAL MESSAGE 3007 (BNDSPC) ILLEGAL INPUT TO SUBROUTINE BNDSP3

Description

Avoidance: Possible DMAP avoidance is to test for the presence of coordinate systems and/or SPC's on boundary points of the superelement. If neither of these exists, the call to the BNDSPC module may be skipped with DMAP as neither YS nor USET is updated.

Known Error

CR 1-26047321

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Description

Optimization/Design Sensitivity - UFM 7544 (DSAD13) Issued in error The following error message may be issued in error when a DRESP1 requests a CFAILURE response with item code 7 (interlaminar shear) and this is the last response applied to the element. *** USER FATAL MESSAGE 7544 (DSAD13) DRESP1 ID 7 IS A CFAILURE RESPONSE WITH ITEM CODE 7: INTERLAMINAR STRESS/STRAIN. USER INFORMATION: THIS RESPONSE IS BEING APPLIED TO PLY NUMBER 7, WHICH IS THE FINAL PLY. INTERLAMINAR STRESS/STRAIN RESPONSES ARE NOT AVAILABLE FOR THE FINAL PLY USER ACTION: DO NOT APPLY ITEM CODE 7 TO THE FINAL PLY User Information: Responses are ordered by element id, ply no and item code. If the last cfailure response for an element has item code 7, the above fatal message is produced regardless of the ply no. it is associated with. The message is only correct when the ply is the highest numbered ply for the element.

Known Error

CR 1-26047321 Avoidance: An avoidance is to request an additional CFAILURE response for the element that has a higher item code (8 or 9) or is applied to a higher numbered ply than the item code 7 request.

Known Error

CR 1-26132368

Product

MSC / MD Nastran

Corrected Version Abstract

Nastran Reference Manual:Incorrect documentation of CQUADR use with SNORM and offsets In the V2005 MSC Nastran Reference Manual, Chapter 3, Structural Elements, Section 3.3.3 New QUADR and TRIAR Elements, Shell Models and Shell Normal Section, the last sentence says:

Description

Shell normal yields wrong results for elements with offsets. Therefore, the shell normal should be turned off globally (PARAM,SNORM,0.0) or turned off locally with the Bulk Data entry, SNORM." This is incorrect and should be removed.

Known Error

CR 1-26140321

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Transient Analysis - IC - UFM 5423 (SADD5) A modal transient analysis, SOL 112, that specifies an initial condition of the form: IC(statsub,diffk)= may fail with the message:

Description

*** USER FATAL MESSAGE 5423 (SADD5) ATTEMPT TO ADD INCOMPATIBLE MATRICES FILE# COLS ROWS FORM TYPE NZWD DENS TRAILER FOR ICSTSBYY IS 101 1 1200 2 2 2400 10000 TRAILER FOR ICSPCD IS 102 3 1200 2 2 2400 6667 Avoidance: Insert the following DMAP alter or use SOL 109. compile semtran alter 'call xadd5.*icphysyy,icspcd,,,',''

Known Error

CR 1-26140321 add icphysyy,icspcd/icphysy1 $ alter 'call xadd5.*icstsbyy,icspcd,,,','' add icstsbyy,icspcd/icstsby1 $

Known Error

CR 1-26152834

Product

MSC / MD Nastran

Corrected Version 2005.5.2 Abstract

Aeroelastic Analysis - AEUXREF - Reference stability derivatives incorrect if aeuxref=trim

Description

If the user puts "aeuxref=trim" in the case control for a sol144 analysis, the resulting stability derivatives for the reference point will be wrong.

Known Error

CR 1-26411375

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Description

Nonlinear Analysis - NLPARM Defaults differ with BLANK continuation vs No Continuation PARAM,NTOL provides incorrect values for the error tolerance when the NLPARM continuation entry is included and the EPSU, EPSP, AND EPSW fields are blank.

Avoidance: Either explicitly set the error tolerances or delete the NLPARM continuation entry. Known Error

CR 1-27310471

Product

MSC / MD Nastran

Corrected Version

2005.5.2

Abstract

Performance - DCMP - Poor Performance on HP IA64 V2005.5.0 (a.k.a 2005r3)

Description

The performance in the DCMP module of Version 2005.5.0 HP IA-64 systems may be severely degraded. Since this is a performance critical module, MSC recommends that the analysis executable be replaced. A corrected executable may be found on the product update site at: http://www.mscsoftware.com/support/software_updates/index.cfm#nastran

Known Error

CR 1-27318160

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Elements - PBMSECT - Arbitrary Section, Incorrect direct shear stresses

Known Error

CR 1-27318160

Description

The direct shear stresses are off by a factor of the area. The forces sent to the routines that calculate cross section stresses are inadvertantly divided by the area prior to the stress calculation.

Known Error

CR 1-28171504

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Documentation/QRG - description for K1/K2 of PBAR in QRG

Description

Remark 5 under the QRG description for the PBAR entry should read transverse shear stiffness times unit length instead of per unit length.

Known Error

CR 1-28310299

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Superelements - EXTSEOUT, acoustic cavity, AUTOQSET- SFM 6143 When creating an external superelement with an acoustic cavity and PARAM,AUTOQSET,YES the run may fail with SFM 6143. For example:

Description

SYSTEM FATAL MESSAGE 6143 (UMRGE1) THE SIZES OF THE INPUT MATRICES AND THE DOF SETS ARE INCOMPATIBLE. SPECIFICALLY: The number of columns in EXTDB is not equal to the size of the A-set User Information: Size of input matrices and DOF sets: EXTDB : Rows= 248 by Cols= 33 Set sizes: Major (G-set)= 278 Set0 (A-set)= 248 Set1 (COMP-set)= 30 Avoidance: Insert the folowing DMAP alter: compile extout alter 'MPYAD INTEXTA,AA,'(,3),'' umerge1 usetx,extdb,,,/temp/'g'/'a'//1 $

Known Error

CR 1-28316191

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Aeroelastic Analysis - MONDPS1 - Output missing in SOL 144 runs

Description

The MONDPS1 feature was added in Version 2005R3. Due to a dmap error, the prints associated with this entry are not produced in a static aeroelastic

Known Error

CR 1-28316191 run. User Avoidance: Insert the following dmap alter in the run: compile mnpntdr list alter 'aero'(3,-1) IF ( DSP1=-1 and (statics or app='reig') ) THEN $ MPYAD SDMPIVa,Ua,/UMONDISP/1 $ mppstatc casedr,dispmon,umondisp,//'MONDISP' $ ENDIF $ DSP1=-1 existing tpl deck msimpms.dat shows the affect of this fix. EHJ 5/24/2006 alter 'umondisp'(1,-1),'umondisp'(1,3)

Known Error

CR 1-31110515

Product

MSC / MD Nastran

Corrected Version Abstract

Topology Optimization - MAT2 - Poor Message

Description

In topology optimization, when a PSHELL entry references a non-supported material such as a mat2 entry which is not, UFM 2042 is issued from routine ifp10e and indicates an undefined material property id. The message should indicate that the material is not supported in topology optimization.

Known Error

CR 1-31899071

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

ACMS - MDACMS with PARAM,SPARSEDR,NO causes wrong eigen vectors in SOL 103 MDACMS causes zero eigen vectors for all grids and all modes if PARAM,SPARSEDR,NO is used. GDACMS with PARAM,SPARSEDR,NO seems correct except the xdb problem reported as Quality #1-31899102.

Description

Avoidance: Insert the following DMAP alter: compile modefsrs alter 'if ( mdacms and','' TYPE PARM,NDDL,CHAR8,Y,sparsedr $ if ( mdacms and ((sparseph='yes' and app'reig') or (sparsedr='yes' and app='reig')) ) then $

Known Error

CR 1-31899102

Known Error

CR 1-31899102

Product

MSC / MD Nastran

Corrected Version GL Abstract

Post-processing - param,post,0- Eigen vectors in xdb file are wrong in SOL 103 GDACMS Eigenvectors in the xdb file are wrong if GDACMS is used in SOL 103.

Description Avoidance: op2, f06, and punch files are correct Known Error

CR 1-32732801

Product

MSC / MD Nastran

Corrected Version 2005.5.2 Abstract

MDACMS - READ - Poor Performance for large problems Assumptions made inside the READ module are may be too conservative and may result in poor performance in MDACMS for large models. Avoidance: Increase memory. Fix was made to reigl0.F.

Description

c if the mass matrix is small and dense, store it in core IF (MSGLVL .GT. 0) WRITE(NF04,1111) N, IFILE(7), LCORE, LCORE/3 1111 FORMAT(' Reigl0: ',4i15) IF (N .LT. 20000) THEN c make this test first so as to not square N unnecessarily and have it c overflow ldm = ior( n, 1 ) mincor = ldm*ldm*iprec IF (IFILE(7).GE.9000 .AND. MINCOR.LT.LCORE/3) THEN DENMAT = LCORE - MINCOR - 5 DENMAT = IOR( DENMAT, 1 ) LCORE = DENMAT - 10 CALL GOPEN( IFILE, 0, RDREW ) MPTR = DENMAT DO I = 1,N CALL UNPACK( *54, IFILE, Z(MPTR) ) GO TO 56 54 CALL ZEROC( Z(MPTR), LDM*IPREC ) 56 MPTR = MPTR + LDM*IPREC END DO CALL CLOSE(IFILE, 1)

Known Error

CR 1-32941641

Product

MSC / MD Nastran

Known Error

CR 1-32941641

Corrected Version 2008.0.0 (MD R3) Abstract

SOL 400 - TTEMP, TID, CROD, CONROD, CTUBE - Wrong Answers

Description

If time dependent loads are defined on TTEMP entry in SOL 400 for CROD, CONROD, or CTUBE elements wrong answers will result.

Known Error

CR 1-33227944

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Cyclic Symmetry - SPCD, STATSUB - UFM 3046 or wrong answers The SPCD entry is ignored as a preload in cyclic buckling (SOL 116), cyclic normal modes (SOL 115), and frequency response analysis (SOL 118). Avoidance: Insert the following DMAP alter in V2008:

Description

compile phase0 alter 'gp4.*caseq','' GP4 CASEfr,GEOM4S,EQEXINS,SILS,,BGPDTS,CSTMS, medge,mface,,geom2s,gdntab,ects,gpsnts,geom1s, actnods/ RMG,Yg1,USET0,gpsntn,ymu,/ LUSETS/S,N,NOMSET/0/S,N,NOSSET/s,n,nooset/ S,N,NORSET/NSKIPX/0/0/0/0/SEID/ALTSHAPE/sebulk/ automset/snormprt/s,n,newgpsn/atqset/nlrigid $

Known Error

CR 1-33238331

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Optimization - mattx associated with a matx referenced by a dvmrel1 Wrong Sensitivies If a dvmrel1 (or dvmrel2) references a matx entry (e.g., a mat1) that has an affiliated mattx entry (e.g., a matt1) the senstivities will be wrong whenever the value determined from the mattx entry differs from that given on the matx entry.

Description

User information: It has never been possible to design a material property that varies as a function of temperature provide by a tablem1 entry. However, it should be possible to support desiging a material property that is not a function of temperature when other properties are a function of temperature. For example, if the Young's module is a function of temperature, but the density is not, it should be possible to design the density. Because of a bug, the sensitivities in this case will be incorrect.

Known Error

CR 1-33238331 User avoidance: There is no avoidance except to not use temperature dependent properties for any material id that has designed properties. The probelm has been fixed by another CR1-44744683.

Known Error

CR 1-33441861

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

ADAMSMNF - FLEXONLY=YES option gives large XDB with no results An analysis in Version 2006 or 2007 with ADAMSMNF FLEXONLY=YES may produce a large xdb file that the direct results access code in Patran is unable to read.

Description

Avoidance: The error may be avoided in some situattions by applying the following dmap alter: alter 'dbcapps' dbcapp='reig ' dbcapps='stat '

Known Error

CR 1-33515609

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

External Superelements - No q-set - UFM 6962 (MATGEN) An extseout SOL 103 run to output the acoustic-structure coupling matrix AAAX in DMIG using the FSCOUP option, fails with the message: *** USER FATAL MESSAGE 6962 (MATGEN) ILLEGAL VALUE FOR PARAMETER 2 = -1

Description

Avoidance: Specify undocumented paramter PARAM,AGGPCH,YES or insert the following alter: COMPILE PHASE1B ALTER 'IF ( SPLITFS )','' IF ( SPLITFS AND NOQSET>-1 ) THEN $

Known Error

CR 1-33793531

Product

MSC / MD Nastran

Known Error

CR 1-33793531

Corrected Version 2007.0.0 Abstract

SOL 600 - Translation of BCBODY LINE section into CONTACT option is wrong if 8 or more points

Description

When there are 8 or more points in the LINE section of a BCBODY the translation of the BCBODY LINE section into the CONTACT option is wrong.

Known Error

CR 1-34254660

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Nonlinear Analysis - CQUAD4 with offsets and MATS1 Plastic Material Wrong Answers

Description

An input file with plastic material properties where the highest stress is well below the yield point fails to produce correct stress results when compared to results without the MATS1/TABLES1 entries. SOL 106 and 400 yield the same bad results. The problem is that the presence of a MATS1 entry turns off the effects of the offsets.

Known Error

CR 1-34278877

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Optimization/Design Sensitivity - PBARL, PBAR, PBEAM, PBEAML - Missing entries in punch file When an optimization job includes both PBARL and PBAR entries and PBAR properties are being designed, no updated PBAR entries are written to the punch file at the end of the design. This shows up either with the DESPCH/DESPCH1 request or the ECHO=PUNCH(NEWBULK) request.

Description

Avoidance: Add a dummy pbrsect entry if the input deck has PBARL (or dummy PBMSECT if has PBEAML). An example as follows POINT 80001 0.0 0.0 POINT 80002 1.0 0.0 set1 80003 80001 80002 pbrsect 80004 1 OP OUTP=80003,t=1.0

Known Error

CR 1-34626031

Product

MSC / MD Nastran

Corrected Version 2007.1.0

Known Error

CR 1-34626031

Abstract

Parallel Processing - SYSTEM(107), PARALLEL -Shared Memory Parallel is not functioning on Windows 64

Description

Shared Memory Parallel is not functioning on Windows 64 in MD Nastran R1.

Known Error

CR 1-34778999

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

SOL 600 - CBUSH1D element causes SOL 600 to fail without any messages.

Description

The CBUSH1D element causes SOL 600 to fail without any messages.

Known Error

CR 1-34831285

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Aeroelastic Analysis - Labelling for inertial derivatives in static aeroelasiticity is incorrect

Description

The trim results for rotational accelerations currently show units of length/s/s when PARAM ANITS=1.0 (default) is used. This should be radians/s/s When PARAM AUNITS has some value other than 1.0, the rotational accelerations are labled as LOAD FACTOR. This should be radians/s/s_per_g

Known Error

CR 1-34885331

Product

MSC / MD Nastran

Corrected Version 2006.0.1 Abstract

SOL 700 - BSURF - Translation Error, Undefined Node Number A BSURF entry with many elements may result in the dytran-lsdyna executable failing due to a translation error. The error message will indicate:

Description 0 *** Error undefined node # 0 near input line 3275 280 0 0 0 0 0.000E+00 0.000E+00 1.000E+00 1.000E+00 Known Error

CR 1-34885375

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

SOL 700 - CTETRA10 - Not translated correctly

Description

The model has an error but the error message is not clear. To fix the model, the PSOLID entry should be changed to PSDOLIDD,1,1,16 which designates

Known Error

CR 1-34885375 that a tet10 will be used in the LsDyna calculations including contact. Once this is done, the tet10 elements run properly. CTETRA10 is not supported in SOL700. If inlcuded the translation will cause an error in the explicit solver.

Known Error

CR 1-34974981

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

SOL 400 - QUAD4, PARAM,LGDISP - UFM 4551 or Floaing Point Overflow in xqd4pd

Description

SOL 400 with CQUAD4 elements and PARAM,LGDISP may fail with UFM 4551 or a floating point overflow in xqd4pd.

Known Error

CR 1-34997021

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Dynamics - PARAM,AUTOQSET,YES - SFM 3001 in TA1 If PARAM,AUTOQSET,YES is requested with nonstructural mass specified on the NSM* entry then the run will terminate with: *** SYSTEM FATAL MESSAGE 3001 (TA1) THE OUTPUT DATA BLOCK IN POSITION 9 DOES NOT EXIST. Avoidance: Insert the following DMAP alter:

Description compile phase1dr alter ' ta1 ','' TA1 mpts,ECTS,EPTS,BGPDTS,SILS,ETT,CSTMS, dit,ectas,eht/ EST,,GEI,GPECT,,vgfd,ditid,,nsmest/ LUSETS/-1/S,N,NOSIMP/1/S,N,NOGENL/0/// s,n,freqdeps/shldamp/s,n,mge/nsm $ Known Error

CR 1-35331198

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Superelements/Acoustics - PARAM FLUIDSE, c-set - SFM 5423

Description

A model with PARAM,FLUIDSE and some or all of the fluid superelement's boundary is in the c-set then the run will fail with:

Known Error

CR 1-35331198 *** SYSTEM FATAL MESSAGE 5423 (MPYAD1) ATTEMPT TO MULTIPLY INCOMPATIBLE MATRICES FILE# COLS ROWS FORM TYPE NZWD DENS TRAILER FOR MOT1 IS 101 313 606 2 2 1212 9665 TRAILER FOR GOQ IS 102 10 919 2 2 1838 10000 TRAILER FOR (NONE) IS 0 0 00000 TRANSPOSE FLAG IS 1 Avoidance: Insert PARAM,MHRED,NO or insert the following DMAP alter: compile semr3 alter 'if (mhred='(2),'' IF ( MHRED='YES' AND NOT(FLUID) ) THEN $ endalter

Known Error

CR 1-35365026

Product

MSC / MD Nastran

Corrected Version GL Abstract

Matrix Methods - DECOMP - PARAM,ASING,-1 DCMP, ERR flag In an analysis which has null columns in the stiffness matrix (plane strain for example) where the null columns are retained in the L-set, the DCMP module will cope with these null columns by placing 1.0 on the leading diagonal of the null columns. This behavior is controlled in subDMAP SEKRRS (for SOL 101) by the DECOMP parameter which is forced to a value of 16 if user parameter ASING is left at its default value of 0.

Description

However, if PARAM,ASING,-1 is set the DECOMP parameter retains the value -1, and the action taken in DCMP is the standard action of replacing every zero term on the leading diagonal with 1E-10. Normally (when the zero terms on the leading diagonal are not also part of a null column) this would set the ERR parameter to -1 on exit from the DCMP module and the DMAP would trap this and issue a UFM. However, starting from Version 2004.5, the ERR parameter is not set to -1 when the zero leading diagonal term comes from a null column. The consequence is that any loads applied to singular dofs generate large displacements (if ASING is set to -1) and displacements equal to the value of the applied load (if ASING is left at 0).

Known Error

CR 1-35436091

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

SOL 600 - BCBODY to CONTACT is wrong for 2nd rigid body represented by NURBS

Description

The 2nd (and perhaps all except the 1st) rigid body represented by NURBS is wrong. The Nastran-to-Marc translator does not write the "data" section from BCBODY to CONTACT. Note that the translation of the "application region" section (i.e., NURBS section) is correct for all the rigid bodies.

Known Error

CR 1-35546885

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Eigenvalue Analysis - OMODES, RESTART - Wrong Answers The OMODES Case Control command is ignored on restart. Avoidance: Insert the following DMAP alter:

Description

compile super3 alter 'call sedisp'(,-1) delete /UG,QG,QMG,OL1S,gpke $ endalter

Known Error

CR 1-35665271

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Aeroelastic Analysis - MONPNT2 results missing when AECONFIG request is present - UFM 2170 (PARTN2) A MONPNT2 bulk data entry in an input file that also contains an AECONFIG case control command produces the following error message:

Description

*** USER FATAL MESSAGE 2170 (PARTN2) BOTH THE ROW AND COLUMN PARTITIONING VECTORS ARE PURGED AND ONLY ONE MAY BE. 0FATAL ERROR

User Information: This is caused by a datablock qualifer not being set.

User Avoidance: The easiest avoidance is to omit the AECONFIG case control command so that the default value of AECONFIG=AERO2GSD is used.

Known Error

CR 1-35665271 :

Known Error

CR 1-35683049

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Nonlinear Transient Analysis with rotordynamics - RGYRO, UNBALNC - SFM 3001 If there are multiple subcases in SOL 129 with RGYRO command and UNBALNC loads then the run may fail with SFM 3001 for UNBVECD. Avoidance: Insert the following DMAP alter:

Description

compile nltran alter 1 file UNBVECD=save $ alter 'call gyrotran' DELETE /UNBVECD,,,, $ endalter

Known Error

CR 1-35833199

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Optimization/Design Sensitivity - DOM9, PBRSECT - SFM 4276, EC 7777

Description

A SOL 200 analysis with arbitrary beam (PBRSECT) failed in the DOM9 with SYSTEM FATAL MESSAGE 4276 Error Code 7777

Known Error

CR 1-35917921

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Case Control - Scale Factor applied to P2G lead to UWM 2070, followed by UFM 300

Description

Attempting to apply a scale fact to P2G, (i.e. P2G = 1.25*PAX) may lead to user fatal message 300 in the case control section.

Known Error

CR 1-35963377

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

ACMS - DOMAINSOLVER - UWM 7795 refers to obsolete methods "MDMODES", "GDMODES", "FDMODES"

Known Error

CR 1-35963377 "MDMODES", "GDMODES", "FDMODES" are still used in output messages (these are v2001 heritage domainsolver terms), yet the DOMAINSOLVER terms have been updated to STAT, MODES and FREQ, with partitioning options DOF, GRID, and FREQ.

Description

*** USER WARNING MESSAGE 7795 (PREDRV) AUTOMATIC MODEL PARTITIONER WAS UNABLE TO PARTITION THE MODEL. USER ACTION: 1. SELECT A DIFFERENT NUMBER OF PROCESSORS OR RUN THE JOB SERIALLY, OR 2. IF DOMAINSOLVER MDMODES WAS SELECTED, THEN SWITCH TO DOMAINSOLVER GDMODES, ACMS OR FDMODES. ^^^ SYSTEM FATAL MESSAGE 9130 (MDMODES) ^^^ AN ERROR HAS OCCURRED WHILE CREATING THE PARTITIONS, THE PERMUTATION MATRIX AND THE MAPS IN PRESOL, WHICH ARE NECESSARY FOR MDMODES. THE READ MODULE WILL BE EXECUTED IN PARALLEL USING FDMODES INSTEAD OF MDMODES.

Known Error

CR 1-35970568

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Documentation/ QRG - DOMAINSOLVER - Table 3-1 GEOM/GRID option

Description

Table 3-1 under the QRG documentation for the DOMAINSOLVER commdand refers to the GEOM option. This should be the GRID option.

Known Error

CR 1-36038197

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

Transient Response - XYPUNCH has a default of MaxShear, not von Mises. If a transient response analysis requests stress printout and also xypunch stress output for item code 9, 17, the xypunch stress output will be von Mises stress, because the default for the stress printout in the .f06 is von Mises. However, if printed output is not requested the XYPUNCH output will be Max Shear.

Known Error

CR 1-36038197 The default XYPUNCH stress will be changed to von MIses to match that of printed output. ******************** Fixed V2007.0.0

Known Error

CR 1-36066967

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Optimization - SOL 200 with SE and TEMP(LOAD) - UFM 3003 (SDR2) or (SSG1) Data Block ETT SOL 200 with superelements and analysis = buck and temperature loads with SCR=NO may fail in data recovery with *** SYSTEM FATAL MESSAGE 3003 (SDR2) ATTEMPT TO READ PAST THE END OF A LOGICAL RECORD IN DATA BLOCK ETT (FILE 107) IN SUBROUTINE GETEMP 0FATAL ERROR or with SCR=YES, may fail with: *** SYSTEM FATAL MESSAGE 3003 (SSG1) ATTEMPT TO READ PAST THE END OF A LOGICAL RECORD IN DATA BLOCK ETT (FILE 107) IN SUBROUTINE GETEMP

Description

NOTE SCR=NO is more efficient for design optimization with SE because the SE does not have to be recomputed and re-reduced at each cycle if there are no design variables in the SE. Avoidance: Apply the following dmap alter: compile update,list $ alter 'gp3','' $ IF ( NOT EXTER ) GP3, GEOM3s,BGPDTS,GEOM2s,EDT,UGH,ESTH,BGPDTH,CASEHeat,mpts,/ SLT,ETT/0/0/0 $ compile desinit $ alter 'lpflg = 0' $ tabpt slist,emap,,, // $ alter ' sdsa '(,-1) $ if ( seid=0 ) then $ alter ' sdsa ' $ else $ desvar = 0 $ dresp = 0 $

Known Error

CR 1-36066967 endif

Known Error

CR 1-36079438

Product

MSC / MD Nastran

Corrected Version 2005.5 Abstract

Composites - PRTPCOMP (sys 361) ignored if "MEM" option used on PCOMP - Extra Output

Description

If PCOMP has "MEM" option, the equivalent PSHELL/MAT2 are printed regardless of the PRTPCOMP value

Known Error

CR 1-36316035

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Documentation/QRG - CQUAD4, CTRIA3 - Offsets, ZOFF

Description

Remark 6 of the QRG CQUAD4 and CTRIA3 description is in error. For CQUAD4 and CTRIA3 with offset (due to ZOFFS and/or unsymmetric plies and/or z0 defined on PCOMP or PCOMPG) the differential stiffness is incorrect. Hence solutions with the need for differential stiffness (dynamic analysis with prestress, linear and nonlinear buckling) will produce incorrect results. However solutions with nonlinear geometric behavior (param,lgdisp,1) will produce correct results when the solution has converged. Please note that QUADR and TRIAR with offset will give incorrect results in any case.

Known Error

CR 1-36462622

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract Description

Documentation - QRG - PFAST - case MCID=0 and MFLAG=0 is missing Remark 5 under the PFAST description in the QRG should be changed to read: If MCID>=0 ... instead of MCID>0 ...

Known Error

CR 1-37202949

Product

MSC / MD Nastran

Corrected Version 2010.1.1 Abstract

Documentation/QRG - MCFRACTION - UWM 3001

Description

A request of MCFRACTION output for a SET that contains no degrees of freedom in the analysis set, will result in the message:

Known Error

CR 1-37202949 *** SYSTEM WARNING MESSAGE 3001 (MCFRAC) THE INPUT DATA BLOCK NAMED RPHMCS AT POSITION 5 DOES NOT EXIST. For example: SET 98765 = 61/t1 SET 88765 = 0.1,0.2 $ mcfraction(structure,print,punch,solution=88765, sort=absd,key=fraction,filter=0.0,null=12, items=(fraction,scaled)) = 98765 where t1 of grid 61 is constrained in the s-set will result UWM 300.

Known Error

CR 1-37227076

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

SOL 600 - Loads in SOL 600 subcase get incorrectly applied

Description

For SOL 600, If the same load is applied in two subcases you must use PARAM,MRDISCMB,1 At the request of Marc development, this parameter was introduced together with an algorithm to combine distributed loads with the same magnitudes. This algorithm fails in problems where just one distributed load of the same magnitude is applied in two subsequent load cases. The default for PARAM,MRDISCMB will be changed to zero for such loadings. The avoidance is to apply slightly different distributed loads. It is unlikely likely that In a practical problem with many loads of varying magnitude that this problem will be encountered.

Known Error

CR 1-37426759

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Parallel Processing/Frequency Response - Poor DMP Performance with multiple load cases The code change was

Description

For any SOL 111 modal frequency response analysis with multiple load cases, DMP performance will suffer during MPI communication of the dynamic load matrix. Avoidance: apply the following DMAP alter:

Known Error

CR 1-37426759 compile freqrs alter 'DISUTIL ppfe', '' $ type parm,,i,n,iproc $ iproc=2 $ do while ( iproc0 ) then $ partn k4gg,nzk4,/k4xx,,, $ remove null columns/rows partn rgq,,nzk4/rxq,,,/1 $ and corresponding rows partn rgt,,nzk4/rxt,,,/1 $

Known Error

CR 1-40966401 smpyad rxq,k4xx,rxq,,,/k4qq/3////1////6 $ smpyad rxt,k4xx,rxq,,,/k4tq/3////1 $ delete /rxt,rxq,,, $ else $ smpyad rgq,k4gg,rgq,,,/k4qq/3////1////6 $ smpyad rgt,k4gg,rgq,,,/k4tq/3////1 $ endif $ if ( not beigrd ) then $ matmod bgg,,,,,/nzb,/12/s,n,nzb/1 $ if ( nzb>0 ) then $ partn bgg,nzb,/bxx,,, $ remove null columns/rows partn rgq,,nzb/rxq,,,/1 $ and corresponding rows partn rgt,,nzb/rxt,,,/1 $ smpyad rxq,bxx,rxq,,,/bqq/3////1////6 $ smpyad rxt,bxx,rxq,,,/btq/3////1 $ delete /rxt,rxq,,, $ else $ smpyad rgq,bgg,rgq,,,/bqq/3////1////6 $ smpyad rgt,bgg,rgq,,,/btq/3////1 $ endif $ endif $ not beigrd dbstatus mbqq//s,n,nombqq $ if ( nombqq>0 ) then $ if ( kdampx>-1 ) then $ add5 bqq,mbqq,,,/mbqq1 $ equivx mbqq1/bqq/-1 $ else $ add5 k4qq,mbqq,,,/mk4qq1 $ equivx mk4qq1/k4qq/-1 $ endif $ endalter

Known Error

CR 1-40966515

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Description

Elements - Multiple element types with many property entries - Poor performance in TA1 If there are multiple element types and at least one element type has many property entries then poor performance may be observed in the TA1 module executed in subDMAP PHASE1A. This error can occur if there is a TOPVAR entry present or there is a unique property entry assigned to each element. Avoidance: Insert the following DMAP alter:

Known Error

CR 1-40966515 compile phase1a alter ' ta1 '(2,-1) putsys(1,56) $ alter ' ta1 '(2) putsys(0,56) $ endalter

Known Error

CR 1-41008771

Product

MSC / MD Nastran

Corrected Version 2007.0.0 (MD R2) Abstract

Fatal Error in DBEADD for problem in AESO and MDACMS A duplication of datablock name in DELETE Dmap could lead to a Warning and follows by a Fatal Message. The example below will demonstrate the error because of duplicated MDABQT datablock: DELETE /MDAMQT,MDABQT,MDABQT,MDK4QT, $

Description

*** SYSTEM WARNING MESSAGE 1113 (DBEDEL) WHILE ATTEMPTING TO DECREMENT THE PVA TABLE COUNTER, NO ENTRIES WERE FOUND FOR THIS PATH. USER ACTION: MAKE RUN USING FMS COMMAND DBFIX *** SYSTEM FATAL MESSAGE 1112 (DBEADD) ATTEMPT TO ADD A DBENTRY IN A LOCATION WHERE ANOTHER DBENTRY ALREADY EXISTS. USER ACTION: CONTACT MSC.SOFTWARE. BIOMSG: ERROR 3061 HAS OCCURRED IN ROUTINE SYSTEM , FILE INDEX = 0. STATUS = 0 Avoidance: Remove the duplication of datablock name

Known Error

CR 1-41130517

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract Description

Optimization/Design Sensitivity - SFM 3007 (DSAD) ILLEGAL INPUT TO SUBROUTINE DSAD6, UFM 6553 The message:

Known Error

CR 1-41130517 SYSTEM FATAL MESSAGE 3007 (DSAD) ILLEGAL INPUT TO SUBROUTINE DSAD6 appears when a scaled weight constraint is invoked in a subcase other than the first. This occurs in combination with the message: USER FATAL MESSAGE 6553 (DOPR3R) A WEIGHT RESPONSE HAS BEEN INVOKED BY THE DESSUB COMMAND IN SUBCASE 22, WHICH IS NOT THE FIRST SUBCASE. It is possible that this UFM will not cause the run to stop due to a programming bug. Avoidance: Constraints on weight or volume must be placed above the subcase level or in the first subcase

Known Error

CR 1-41285296

Product

MSC / MD Nastran

Corrected Version GL Abstract

SOL 600; read error: no such option (caused by space in path) .SOL 600 does not support spaces in any path and there is no intent to do so. Such jobs will be fataled out for MD R2. For MD R3 and subsequent releases spaces in the path are allowed. A SOL 600 job that is run from a directory that has a space in the path will fail with a message similar to the following:

Description

Marc will be executed using the command: f:\msc\nast2005r3\msc20055\marc\\tools\run_marc.bat -jid F:\clients\space in path\ddd.marc.dat -v no -iam nanl -sdir g:/scratch -b no *** ISHELL PROGRAM 'f:\msc\nast2005r3\msc20055\marc\\tools\run_marc.bat' STARTED *** read error: no such option: in or input value: path\ddd.marc.dat *** ISHELL PROGRAM 'f:\msc\nast2005r3\msc20055\marc\\tools\run_marc.bat' COMPLETED *** AVOIDANCE: remove spaces from the path

Known Error

CR 1-41330851

Known Error

CR 1-41330851

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Optimization/Design Sensitivity - tpl test dtrustr2 fails in DOM10 - SFM 4276 on AIX An optimization job with an active Trust Region request may fail in DOM10 with SYSTEM FATAL MESSAGE 4276.

Description

Avoidance: use the dmap alter below: compile desopt alter 'if ( trustR ) D','' if ( trustR ) THEN DBEQUIV DATABLK=(XINIT/XINITR,DESTAB/DESTABR, OPTPRMG/OPTPRMGR,R1VALRG/R1VALRGR,R2VALRG/R2VALRGR, RSP2RG/RSP2RGR,R3VALRG/R3VALRGR, R1TABRG/R1TABRGR,CNTABRG/CNTABRGR,DSCMG/DSCMGR, OBJTBG/OBJTBGR,RR2IDRG/RR2IDRGR, RESP3RG/RESP3RGR,RQATABRG/RQATBGR, DRSTBLG/DRSTBLGR,WMIDG/WMIDGR, MODRPRG/MODRPRGR,GEOM1/GEOM1R,GEOM2/GEOM2R, GEOM1QS/GEOM1QSR,GEOM2QS/GEOM2QSR, GEOM4QS/GEOM4QSR,FRQRPRG/FRQRPRGR, R1MAPR/R1MAPRR,R2MAPR/R2MAPRR,MTRAK/MTRAKR), WHERE (DESITER=DESCYCLP AND WILDCARD) , CONVERT (DESITER=DESCYCLP+1) OVRWRT $ DELETE /RSP2RG,CNTABRG,R1TABRG,DRSTBLG,FRQRPRG $ DELETE /R1VALRG,R2VALRG,CVALRG,wmidg,r3valrg $ DELETE /RESP3RG,rr2idrg,wgtmg,RQATABRG,modrprg $ DELETE /DSCMG,DELW,DELV,DELB,DELF $ endif

Known Error

CR 1-41392631

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

SOL 600 - MARCPRNH and MARCPR99 cannot correctly converted In SOL600, MARCPRNH and MARCPR99 cannot BE correctly converted to PRINT ELEMENT by the CQUAD4 element.

Description

For example the input cquad4.bdf with: --param,marcprnh,1 param,marcpr99,-1 --cquad4.marc.dat:

Known Error

CR 1-41392631 --PRINT ELEMENT STRESS CAUCHY STRAIN PLASTIC PR999999 1 to 1 1 to 1 --This input file outputs only point1 and layer1.

Known Error

CR 1-41448459

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Single Point Constraints - AUTOSPC, INPUTT4 - Incorrect Constraints when negative terms on diagonal

Description

A matrix that is brought in via INPUTT4 and has negative numbers on the diagonal may cause the wrong degrees of freedome to be constrained by the AUTOSPC gpsp module.

Known Error

CR 1-41458341

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

File Management Section - APPEND - Output datablock via dbview fails The following simple deck fails in gnfist die to an append datalock geom1 that using the alias dbviewname VIEW0001 ASSIGN inputt2='../complex_107.op2',unit=25 status=old acquire nddl sol mysol

Description

compile mysol list subdmap mysol TYPE PARM,,I,Y,IUNIT=25 $ INPUTT2 /,,,,/-1/IUNIT $ TYPE DB GEOM1,GEOM168 $ FILE GEOM1=APPEND $ DBVIEW VIEW0001=GEOM1 WHERE(AUXMID=1;AFPMID=2;DESITER=3;HIGHQUAL=0) INPUTT2 /GEOM168,,,,/0/IUNIT////////'GEOM168' $ MAKENEW GEOM168,,,,/VIEW0001,,,,/'GEOM1'/////'GEOM1' $ IFPINDX /VIEW0001 $

Known Error

CR 1-41458341 DBDIR $ end cend

*** USER FATAL MESSAGE 1126 (GNFIST) DMAP MODULE IFPINDX IS ATTEMPTING TO OUTPUT DATABLOCK 201 NAME = GEOM1 , WHICH ALREADY EXISTS. USER ACTION: DELETE THE DATABLOCK, OR USE FILE GEOM1=OVRWRT Known Error

CR 1-41585731

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Documentation/QRG - SOL 400 - PARAM,KDIAG The description for user parameter KDIAG requires updating. 1. It does not include SOL 400 in the list of applicable solution sequences. 2. For SOL 400, it does not apply only to nonlinear statics but to nonlinear transient analysis as well. Suggested updated description: Default = -1.0 (SOLs 106, 400 and 153 only)

Description

In SOL 106 (nonlinear static analysis), 400 (both nonlinear static and transient analysis) and 153 (steady state heat transfer), KDIAG may be used to eliminate spurious mechanisms and singularities in the nonlinear stiffness matrix. The absolute value of KDIAG will be added to some or all of the diagonal terms in the nonlinear stiffness matrix according to the following: If KDIAG < 0.0, then add the absolute value of KDIAG to the null diagonal terms only. (Default) If KDIAG = 0.0, then no action is taken. If KDIAG > 0.0, then add the value of KDIAG to all diagonal terms.

Known Error

CR 1-41729401

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Documentation/SOL 600 - MARCOUT Defalt

Known Error

CR 1-41729401 The code was revised to make the default t16 file smaller, but the QRG was not revised accordingly.

Description

MD Nastran Quick Reference Guide ch.8 MARCOUT Remarks 6, 6. If this entry is not used, the following defaults are entered automatically: E1, E11, E18, E27, E301, E321, E341, E401, E47, E48, N1, N2, N5, N35, N37, N39. In MD Nastran 2006, if this entry is not used, only E301, E341, E47, N1, N2, N35, N37, N38 and N39 are output.

Known Error

CR 1-41737627

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

SOL 600/Documentation - QRG incorrect for PARAM, MRFOLLOW The electronic 2005r3 QRG indicates: MRFOLLOW Integer, Default = 0, MSC.Nastran Implicit Nonlinear (SOL 600) only MRFOLLOW=1, FORCE1, FORCE2, MOMENT1, MOMENT2 will act as nonfollower forces. This option must be entered if MSC.Marc versions prior to 2003 r1 are to be used. MRFOLLOW=0, follower forces entered using FORCE1, FORCE2, MOMENT1, MOMENT2 will be mapped to MSC.Marc’s new follower force option available starting with MSC.Marc version 2003r1.

Description MRFOLLOW=-1, follower forces will be turned off even if requested to be on using other options. This is sometimes necessary for multiple load cases where pressures are applied to different elements in the different load cases. ========================================== This is incorrect, the doucmentation should indicate: ========================================== MRFOLLOW Integer, Default = 0, MSC.Nastran Implicit Nonlinear (SOL 600) only MRFOLLOW=0, FORCE1, FORCE2, MOMENT1, MOMENT2 will act as nonfollower forces.

Known Error

CR 1-41737627 This option must be entered if MSC.Marc versions prior to 2003 r1 are to be used. MRFOLLOW=1, follower forces entered using FORCE1, FORCE2, MOMENT1, MOMENT2 will be mapped to MSC.Marc’s new follower force option available starting with MSC.Marc version 2003r1. MRFOLLOW=-1, follower forces will be turned off even if requested to be on using other options. This is sometimes necessary for multiple load cases where pressures are applied to different elements in the different load cases. ==========================================

The actual action is opposite what the manual indicates. Known Error

CR 1-41752101

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Frequency Response - OLOAD is ignored in a frequency response analysis when TSTEP is present OLOAD is ignored in a frequency response analysis when TSTEP is present.

Avoidance: Apply the following dmap alter:

Description

COMPILE SEMFREQ $ INVERSE FOURIER TRANSFORM OLOAD, SPCFO, AND MPCFO ALTER 'CALL FDRMGEN'(2,-1) $ APP = 'TRANRESP' $ ALTER 'CALL FDRMGEN'(2) $ APP = 'FREQRESP' $ ALTER 'DELETE.*PPF.*PSF' $ IFT PPFSAVE,CASEF,TRL,FOL/PP147,FOLXXX/IFTM $ MATMOD PP147,,,,,/PPF,/1/1//3 $ COMPILE SEdFREQ $ INVERSE FOURIER TRANSFORM OLOAD, SPCFO, AND MPCFO ALTER 'CALL FDRMGEN'(,-1) $ APP = 'TRANRESP' $ ALTER 'CALL FDRMGEN' $ APP = 'FREQRESP' $ ALTER 'DELETE.*PPF.*PSF' $ IFT PPFSAVE,CASEF,TRL,FOL/PP147,FOLXXX/IFTM $ MATMOD PP147,,,,,/PPF,/1/1//3 $

Known Error

CR 1-41752101 endalter

Known Error

CR 1-41808171

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Description

Aeroelastic Analysis - FLFACT - Floating point exception, divide by zero, subroutine FASORT A divide by zero fatal message will occur for the pk or pknl methods when two consecutive dynamic pressures (= 1/2 density * velocity**2) are the same. User Avoidance: adjust the flfact input for densities and velocities to avoid the duplicate dynamic pressure.

Known Error

CR 1-41822251

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Documentation/QRG - SOL 600 - PARAM,MARCT16 output

Description

The description of Quick Reference Guide(MARCT16) is not correct. It has been updated for the MD Nastran R2 and MSC.Nastran 2007 releases.

Known Error

CR 1-41822276

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Documentation/QRG - SOL 600 - MARCT16 document

Description

The QRG needs to be modified to indicate that MARCOUT should not be entered when PARAM,MARCT16 is used.

Known Error

CR 1-41832822

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Documentation/QRG - SPC Case Control Command missing reference to SPC2

Description

The QRG description of the SPC case control command needs to be updated to indicate that it can reference a SPC2 bulk data entry.

Known Error

CR 1-41883251

Product

MSC / MD Nastran

Corrected Version 2007.0.0

Known Error

CR 1-41883251

Abstract

Matrix Methods - SMETHOD - CASI solver on ILP-64 AIX Fails The element based iterative solver (CASI) will fail on IBM AIX platforms with a Traceback similar to the one reproduced below. Note that this only occurs with the ILP-64 version ("mode=i8"). Avoidance: A possible workaround is to rerun the job with mode=i4. Signal received: SIGSEGV - Segmentation violation

Description

Traceback: Offset 0x00000030 in procedure casiFree Offset 0x00000054 in procedure deleteFMatrix_159_128 Offset 0x00000ca4 in procedure pcgsl Offset 0x000003d0 in procedure pcglss Offset 0x00000078 in procedure xqcasi_ Offset 0x00001010 in procedure itscas_ Offset 0x000008d8 in procedure solvit_ Offset 0x00000670 in procedure xsem07_ Offset 0x00000198 in procedure xsemdr_ Offset 0x00000064 in procedure nastmon_ Offset 0x00000a78 in procedure mainal --- End of call chain ---

Known Error

CR 1-41884101

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Matrix Methods - SMETHOD - CSEAM element not recognized by Casi solver

Description

The casi element-based iterative solver interface does not currently allow the CSEAM element.

Known Error

CR 1-41885454

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

SOL600 - PSHELL, CQUAD4 - Membrane only element incorrectly translated.

Description

In the nastran bulk data a membrane only shell element is defined with a CQUAD4 entry with the MID1 field of the PSHELL entry defined, but MID2, MID3 and MID4 are left undefined. When SOL600 translates this type of element into a Marc element, it uses type 75, a full shell element. This is incorrect, Marc's membrane-only element is type 18.

Known Error

CR 1-41927461

Product

MSC / MD Nastran

Known Error

CR 1-41927461

Corrected Version 2007.0.0 Abstract

Documentation/QRG - SOL 600 - BRKSQL Remarks 7 Remark 7 of the Quick Reference Guide BRKSQL entry description has been updated to reflect the actual code.

Description

In MD Nastran 2006, if METH =1 and ICORD=0 or 1, an MSC.Marc t19 file will automatically be produced. If METH =0 and ICORD=0 or 1, an MSC.Marc t19 file not generate.

Known Error

CR 1-42002359

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Loading - TEMP(INIT), TEMP(BOTH) - Wrong Answers Specifying both TEMP(INIT) and TEMP(BOTH) can lead to wrong answers as follows:

Description

1) if TEMP(INIT) and TEMP(BOTH) -> WRONG ANSWERS (Delta-T is wrong) 2) TREF will NEVER perform table lookup 3) If TEMP(BOTH) and TEMP(LOAD) are specified, only the last request will be honored 4) In SOL 105 ONLY: If TEMP(BOTH) is specified in the subcase, it does not perform This condition will be trapped with a new fatal message beginning in version 2007. USER FATAL MESSAGE XXX (IFP1D) MULTIPLE TEMP(BOTH) OR COMBINATIONS OF TEMP(BOTH) AND TEMP(INIT) ARE NOT ALLOWED.

Known Error

CR 1-42059473

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Matix Methods - SMETHOD - Casi iterative solver does not support K2GG input matrix data

Description

The casi element-based iterative solver interface does not does not support K2GG input matrix data.

Known Error

CR 1-42074241

Product

MSC / MD Nastran

Corrected Version 2007.0.0

Known Error

CR 1-42074241

Abstract

Documentation/QRG - DOBJ2, DPMIN, FSDALP and FSDMAX missing from DOPTPRM description

Description

The 2005R3 QRG inadvertantly deleted fsdmax, fsdalp,dobj2 and dpmin from the DOPTPRM entry. User Information: Refer to the 2005 Quick Reference Guide for information on these parameters.

Known Error

CR 1-42173286

Product

MSC / MD Nastran

Corrected Version Abstract

Postprocessing - POST TOFILE - op2 file cannot be read by Patran When POST TOFILE is being used to control the results output to the op2 file, Patran or other postprocessors cannot read the geometry. This error is caused by CASECCR being written before the results are output.

Description

Avoidance: Apply the following dmap alter: compile super3 $ alter 'OUTPUT2.*CASECCR','' $

Known Error

CR 1-42236771

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

SOL600 - MATHE-K, MOONEY - Not correctly converted The values of MATHE-K(bulk modulus) is converted to the "coefficient of thermal expansion" and the "bulk modulus" of MOONEY in the marc data. The value of MATHE-Texp is disregarded.

Description

[nastran.dat] MATHE, 2, MOONEY, , 33.0E6, .0003, 2.5E-6, 70.5, .015 , 5.5E6, 1.0E6 , 4.0E6, 0.8E6 , 2.0E6

[marc.dat] MOONEY COMMENT, MATHE 2 1, 2, 5.500000E+06, 1.000000E+06, 7.770000E-07, 3.300000E+07, 8.000000E+05, 4.000000E+06, 2.000000E+06, 3.300000E+07,

Known Error

CR 1-42267596

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

DMAP - MATPRN, DUPVH - SFM 4276, EC 3021 The following MATPRN caused EMG to fail with SYSTEM FATAL MESSAGE 4276 (READ) ERROR CODE 3021

Description compile NONLIN LIST alter 'EMG .*ESTNL.*UGNIX'(1,-1) $ MATPRN DUPVH// $ Known Error

CR 1-42405257

Product

MSC / MD Nastran

Corrected Version Abstract

Optimization/Design Sensitivity - DRESP1, FORCE, STRESS(BILIN) - Incorrect Item Code

Description

A DRESP1 entry that references a force, stress, and/or strain item code for a CQUAD4 element may use the wrong response if the FORCE output request is different than the STRESS or STRAIN output request. For example STRESS(BILIN) is requested and FORCE(CENTER) is requested.

Known Error

CR 1-42425397

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Nonlinear Analysis - CGAP, TEMP(LOAD) - UFM 2044, UFM 3007 Nonlinear analysis with CGAP entries and TEMP(LOAD) may fail with the following fatal messages:

Description

*** SYSTEM INFORMATION MESSAGE 6916 (DFMSYN) DECOMP ORDERING METHOD CHOSEN: BEND, ORDERING METHOD USED: BEND *** USER FATAL MESSAGE 2044 (NLCOMB) UNDEFINED TEMPERATURE SET 104 *** SYSTEM FATAL MESSAGE 3007 (NLCOMB) ILLEGAL INPUT TO SUBROUTINE NLCETT 0FATAL ERROR

Known Error

CR 1-42507691

Product

MSC / MD Nastran

Known Error

CR 1-42507691

Corrected Version 2007.0.0 Abstract

SOL 600 - SPC Incorrectly Translated

Description

In Versions 2005.5.2 and 2006.0.1 enforced displacement of SPC is not translated correctly, though SPCD+SPC is correctly translated.

Known Error

CR 1-42792171

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

SOL 700 - CBEAM - Orientation vector is not correctly translated if BEAMOR is used to define it. If BEAMOR is used to define the orientation vector of a CBEAM, it is not translated correctly. For example, BEAMOR 1. 0. 0. CBEAM 1910002 1000009 1000044 1000045

Description

are translated as shown below into dyt.dat file. CBEAM 1910002 1000009 1000044 1000045 1.00000 and it casuses Error in dytran-lsdyna as shown below. %E *** ErrorMD Nastran Input 153733 CBEAM 1910002 1000009 1000044 1000045 1.00000 invalid integer (1.00000) in field 6 The correct translation for this example is: CBEAM 1910002 1000009 1000044 1000045 1.00000 0.0 0.0

Known Error

CR 1-42803355

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Matrix Methods - DECOMP, METIS - UFM 6413 (DFMSYN) If metis reordering is specified by sys206=8, and more than 2gb of memory is given, the job will always fail with a message similar to:

Description

Known Error

*** USER FATAL MESSAGE 6413 (DFMSYN) INSUFFICIENT MEMORY FOR THE SYMBOLIC PHASE OF SPARSE DECOMPOSITION (METIS). USER ACTION : INCREASE MEMORY BY AN ESTIMATED 524680801 WORDS. CR 1-42936851

Known Error

CR 1-42936851

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Description

Optimization/Design Sensitivity - DRESP1 - SFM 3007 (DSAD) writh RMS or PSD responses The message "SYSTEM FATAL MESSAGE 3007 (DSAD)" can occur when a SOL 200 job contains DREPSP1 entries with RTYPE = PSDXXX and/or RMSxxx and all of the computed response are zero. This typically indicates an error in the user input. Avoidance: Review the specification of the DRESP1 entries with RTYPE = PSDxxxx and/or RMSxxxx to make sure that the requested quantities are non-zero.

Known Error

CR 1-43084871

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Description

SOL 600 - CHEXA (with PSOLID and PLSOLID) is not correctly converted If a model contains CHEXA elements that reference PSOLID entries and others that reference the PLSOLID entry, the input is not translated correctly and the following message is issued: --error message-** Severe Warning in SOL 600 trnslator - CHEXA must have 8 or 20 nodes to be used in SOL 600

Known Error

CR 1-43300972

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Description

Nonlinear Analysis - RFORCE and LOAD(with negative scale factor) - NaN or UFM 4296 (NQD4D) If a SOL 106 run has a LOAD bulk data that references an RFORCE entry with a negative scale factor, either a "NaN" will occur during the first nonlinear iteration or a fatal message will be issued for every quad element in the model. Avoidance: Avoid negative scale factors on the LOAD entry for the RFORCE id.

Known Error

CR 1-43365991

Product

MSC / MD Nastran

Known Error

CR 1-43365991

Corrected Version 2007.0.0 Abstract

SOL 600 - CBUSH1D element is not supported in SOL 600

Description

The CBUSH1D entry is not supported by SOL 600. This entry may cause the sol 600 translator to crash without issuing an error message.

Known Error

CR 1-43440601

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract Description

Matrix Methods - DECOMP, Large Models - Signal 11, Overflow Large dense models over 3 million DOF may cause a signal 11 in DCMP. The error is related to an integer overflow. Avoidance: Submit with more or less memory

Known Error

CR 1-43448777

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Nonlinear Transient Analysis - CMS - UFM 1126 Module UMERGE1 outputtingt GOA which already exists In V2005+, a SOL 129 model with CMS (QSETi) may fail with: *** USER FATAL MESSAGE 1126 (GNFIST) DMAP MODULE UMERGE1 IS ATTEMPTING TO OUTPUT DATABLOCK 201 NAME = GOA , WHICH ALREADY EXISTS. USER ACTION: DELETE THE DATABLOCK, OR USE FILE GOA=OVRWRT Also, if there are unused QSETi degrees-of-freedom then the run may fail with:

Description

*** USER WARNING MESSAGE 6137 (UDSNRD) INPUT MATRIX IS RANK DEFICIENT, RANK = 24 USER ACTION: CHECK MODEL 0*** UNSUCCESSFUL MATRIX DECOMPOSITION. *** SYSTEM FATAL MESSAGE 3007 (NLTRD2) ILLEGAL INPUT TO SUBROUTINE NLTRD2

Avoidance: Insert PARAM,SMALLQ,1.e-10 and the following DMAP alter compile nltran alter 'call segoa'(,6) delete /goa,,,, $

Known Error

CR 1-43465661

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

SOL 600 - MATF - Incorrect maximum compressive stress failure criteria

Description

The maximum compressive stress in the x and y directions as specified on the MATF entry which defines the failure criteria are translated incorrectly.

Known Error

CR 1-43537471

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Aeroelastic Analysis - SPLINE6 - UWM 328, Excessive Output

Description

SPLINE6 entries that do no explicitly define a continuation entry will produce UWM 328 for each entry. This may lead to excessive output.

Known Error

CR 1-43604151

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Nonlinear Analysis - UWM 3057, UFM 3007, for MATS1, NLELAST, TABLES1 w/o origin defined For a material nonlinear run with MATS1 NLELAST and TABLES1, if the origin is not defined on the TABLES1, then the model may go several decomps before finally failing with the following message.

Description

*** USER WARNING MESSAGE 3057 (NLITER) MATRIX IS NOT POSITIVE DEFINITE. *** SYSTEM FATAL MESSAGE 3007 (NLITER) ILLEGAL INPUT TO SUBROUTINE NLINIT This should be trapped as a user input error. The rule is defined in the Quick Ref Guide, MATS1 Remark 3, bullet 2.

Known Error

CR 1-43735881

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

SOL 600 - BCMOVE limitation when BCTABLE with 2 contacts

Description

The BCTABLE implementation in Nastran Version 2006.0.1 and earlier releases does not allow no contact to be defined between a rigid and flexible body. This prevent modelling the contact force from being released gradually.

Known Error

CR 1-43778881

Known Error

CR 1-43778881

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Transient Analysis - GPSTRESS, SORT2, PUNCH - Incorrect time label.

Description

Punched GPSTRESS SORT2 output from a transient analysis may contain incorrect time labels.

Known Error

CR 1-43779004

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Modal Effective Mass - MEFFMASS - UFM 6144 (MERGE1) If MODESELECT is used with MEFFMASS using modal effective mass criterion for mode selection then the run may fail with UFM 6144 (MERGE1):

Description

*** SYSTEM FATAL MESSAGE 6144 (MERGE1) THE SIZES OF THE INPUT MATRICES AND PARTITIONING VECTORS ARE INCOMPATIBLE. SPECIFICALLY: The number of rows in EFMFACS0 is not equal to the number of non-zeros in partitioning vector PARTVECS User Information: Size of input matrices and partitioning vectors: EFMFACS0: Rows= 4 by Cols= 123 PARTVECS: Rows= 6 no. of non-zeros= 6 no. of zeros= 0 Avoidance: A temporary DMAP avoidance: compile modefsrs alter 'noefm' $ noefm=-1 $ A permanent solution to the problem will require code changes to the EFFMAS module.

Known Error

CR 1-43807221

Product

MSC / MD Nastran

Corrected Version 2006.0.1 Abstract

Optimization - ANALYSIS=AERO, DRESP1- SFM 3007 (DSAD) Illegal input to Subroutine DSAD14

Description

The message "SYSTEM FATAL MESSAGE 3007 (DSAD) Illegal input to Subroutine DSAD14" has been observed when DRESP1 entries with RTYPE=FLUTTER are

Known Error

CR 1-43807221 attemped and the flutter method is either PKS or PKNLS. In the case reported, the message was a result of a program bug, but it could also occur properly if a requested flutter root was not extracted. User Avoidance: Use the PK or PKNL flutter methods

Known Error

CR 1-43834511

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Optimization/Design Sensitivity - Missing output for DSAPRT(export,by=1) When keywords export and by=n (n>1) are specified on a DSAPRT Case Control command , the sensitivity data only at the last design cycle is output to the external binary file. Avoidance: use the following dmap alter

Description

compile exitopt list alter 'OUTPUT2 D'(1,-1) type parm,nddl,i,n,zuzri1 $ if ( dsexport) then MESSAGE //'DESIGN CYCLE = '/DESCYCL1 $ if (zuzri1 = 0) then MESSAGE //'=========DSAPRT START =========='/ $ $ alter 'OUTPUT4 D' $ $ Output DSCMCOL And DSCM2 : $ OUTPUT2 DSCMCOL,,,,//-1/IUNIT/'DSCMCOL'/OMAXR $ $ OUTPUT4 DSCM2,,,,//-2/IUNIT $ zuzri1 = 1 else if (zuzri1 >0 and not(lastcyc)) then MESSAGE //'=========DSAPRT MIDDLE =========='/ $ OUTPUT2 DSCMCOL,,,,//0/IUNIT/'DSCMCOL'/OMAXR $ OUTPUT4 DSCM2,,,,//0/IUNIT $ else if (zuzri1 >0 and lastcyc) then MESSAGE //'=========DSAPRT END =========='/ $ OUTPUT2 DSCMCOL,,,,//0/IUNIT/'DSCMCOL'/OMAXR $ OUTPUT4 DSCM2,,,,//-2/IUNIT $ endif $

Known Error

CR 1-43943079

Product

MSC / MD Nastran

Corrected Version 2007.0.0

Known Error

CR 1-43943079

Abstract

Matrix Methods - Singular matrices not flagged with param,asing,-1

Description

PARAM,ASING,-1 should cause nastran to issue a fatal message when a singular matrix is encountered. However, when param,asing,-1 is specified along with autospc=no, a high max ratio may be reported but the execution continues and the offending degrees of freedom are not identified.

Known Error

CR 1-44040531

Product

MSC / MD Nastran

Corrected Version 2006 (MD R1) Abstract

Documentation/SOL 700 User's Guide - Description of WALL/WALLGEO is incorrect. The description of WALL/WALLGEO in the SOL 700 User's Guide is incorrect.

Description Avoidance: Refer to the MD Nastran Quick Reference Guide for the correct description. Known Error

CR 1-44225671

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Documentation/QRG - RBE2/RBE2D description is wrong. The remark 4 of the RBE2D entry in the Quick Reference Guide shown below is wrong. RBE2 without the FULLRIG option can simulate rotations.

Description

4. For modeling a nodal rigid body that undergoes rotations, use RBE2D or RBE2 with the FULLRIG option. Note that the RBE2 without the FULLRIG option can not properly simulate rotations.

Known Error

CR 1-44265142

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract Description

NOLIN - SPOINT - Wrong Answers A NOLIN1 may produce wrong answers when it references an spoint that has its displacement defined using an mpc equation. Avoidance: Insert PARAM,ENFMETH,ABS.

Known Error

CR 1-44398314

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3)

Known Error

CR 1-44398314

Abstract

Nonlinear Analysis - LOAD, Follower Forces, PLOAD4 - Wrong Answers

Description

In SOL 106, if a LOAD bulk data entry references a follower-force type loading (e.g. PLOAD4) and another load set ID that does not exist, AND that missing load set ID is LOWER than the follower force load set's ID, then the follower force loading acts like a linear load and no longer follows the structure as it deforms. If the missing load set ID is higher than the follower force's, then the follower force acts as expected.

Known Error

CR 1-44493881

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

SPCForce Incorrect results SOL112 SPCD vs SOL109 SPCD Client modeled a cantilever beam with a transvers base enforced motion. Client ran in SOL109 and obtained spcforces. Client ran the same problem in SOL112 and the spcforces are different. This appears to be a problem with the implementation of SPCD in modal dynamics. ****************** No avoidance

Known Error

CR 1-44744683

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Description

Optimization/Design Sensitivity - MATT1, MATT9,MATT8 - UFM 2018 (EMG) and/or Wrong Answers 1) When an optimization job includes more than one MATTi types (say MATT1 and MATT9 or MATT1 and MATT8), the job may fail in EMG with UFM2018 or gives wrong sensitivities. 2) When only a sigle MATTi entry exists in a SOL200 job and when some of the property names on its asssoicated MATi entry is also being designed, the resulting sensitivity coefficients may be wrong. The avoidance: do not design MATi that is also associated with a temperature dependent material entry (MATTi). This error is corrected in Version 2007.0.4

Known Error

CR 1-44800991

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3)

Known Error

CR 1-44800991

Abstract

Optimization/Design Sensitivity - MATT1, MATT9 - UFM 2019

Description

A SOL 200 analysis with MATT1 or MATT9 entries will lead to USER FATAL MESSAGE 2019. ************* Fixed MDR3 V2008.0.0

Known Error

CR 1-44900725

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Description

Installation - Unable to find library 'liblapi.sl'. In Version 2005.5 with a MINIMUM install, the following error might occur when attemting to run Nastran: MSC.Nastran started Wed Oct 25 09:50:52 CDT 2006 /usr/lib/pa20_64/dld.sl: Unable to find library 'liblapi.sl'. time: command terminated abnormally. Avoidance: Select a full install

Known Error

CR 1-45244091

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

SOL 700 - PSHELLD* causes UFM 6440 (MODGM2) PSHELLD* causes the fatal error shown below in the MODGM2 module. *** USER FATAL MESSAGE 6440 (MODGM2) ELEMENT 2620121 REFERS TO AN INVALID PROPERTY ENTRY. USER ACTION: SPECIFY APPROPRIATE PROPERTY ENTRY. 0FATAL ERROR

Description

Avoidance: Use the dmap alter below to skip MODGM2 module in SOL 700 MODGM2 IEPT.11,IGEOM2.6,IGEOM1.5,IGEOM4,XBGPDT,XCSTM,IMPT.10/ IGEOM2,IGEOM1Q,IGEOM2DL,IEPT,IMPT/ /OSWPPT/OSWELM/S,N,NSWPPT/S,N,NSWELM/S,N,SWEXIST/ S,N,NOGOMGM2/S,N,RGDEXIST/RIGID/ORIGID/S,N,NLRIGID/ LMFACT/PENFN/NONLNR/CWRANDEL/CWDIAGP/CFRANDEL/CFDIAGP/ S,N,NOEPT/S,N,NOMPT/S,N,NOGEOM1/SOFFSET/CSRANDEL/CSDIAGP $ IF ( NOEPT=-1 ) EQUIVX IEPT.11/IEPT/-1 $ IF ( NOMPT=-1 ) EQUIVX IMPT.10/IMPT/-1 $ IF ( NOGEOM1=-1 ) EQUIVX IGEOM1.5/IGEOM1Q/-1 $

Known Error

CR 1-45244091 IF ( NOGO=0 ) THEN $ IF ( NOGOMGM2 ) THEN $ SPOT WELD CHECK RUN CALL PRTSUM /RSTJUNK $ EXIT $ ENDIF $ NOGOMGM2 ENDIF $ NOGO=0

Known Error

CR 1-45244156

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

SOL 700 - MATD003 can not be used with PBEAMD ELFORM=3 while it is allowed in LS-Dyna. MATD003 can not be used with PBEAMD ELFORM=3 else the following error is output to the dytr_prep.out file.

Description

%E *** Error MD Nastran Inpu pbeamd (= 999999) references wrong material type (= 3) This combination is allowed in LS-Dyna.

Known Error

CR 1-45325022

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Documentation/QRG - System Cell 361(aka PRTPCOMP)

Description

The description of the SYSTEM(361), PRTPCOMP does not state that ECHO=NONE will suppress the printing of the PSHELL/MAT2 equivalent of the PCOMP/MAT8 when it is set to a value of 1. If NASTRAN SYSTEM(361)=1 is used the user must remove the ECHO=NONE to obtain the printed information in the f06 file.

Known Error

CR 1-45325136

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Materials - Missing material entry leads to poor message - UFM 2042 (IFP6) A missing material entry in a large input file issued the following message:

Description

*** USER FATAL MESSAGE 2042 (IFP6) MISSING MATERIAL TABLE 11 FOR ELEMENT 160 *** USER FATAL MESSAGE 2042 (IFP6)

Known Error

CR 1-45325136 MISSING MATERIAL TABLE 11 FOR ELEMENT 161 The message should have indicated that the ids were for the PCOMP not element ids.

Known Error

CR 1-45605382

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Complex Eigenvalue Analysis - CEAD Module UFM 1126 A complex eigenvalue analysis to obtain Campbell diagram data with the keyword scr=no, fails in the CEAD module with: *** USER FATAL MESSAGE 1126 (GNFIST) DMAP MODULE CEAD IS ATTEMPTING TO OUTPUT DATABLOCK 202 NAME = CLAMA , WHICH ALREADY EXISTS. USER ACTION: DELETE THE DATABLOCK, OR USE FILE CLAMA=OVRWRT

Description

Avoidance: Set scr=yes and the attached job runs. Or insert the following DMAP alter: compile sedceig alter 'if ( gcase\>1 or ccase\>1','' if ( gcase>1 or ccase>1 or ddval>0. ) delete /CPHD,CLAMA,lphd,, $ alter 'call super3' if ( ddval>0. ) dbdelete datablk=(cphp,cphqp,cphqmp) , where(wildcard) $

Known Error

CR 1-45630951

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Miscellaneous - RSEQCONT or SYSTEM(357) - UFM 4392

Description

The NASTRAN keyword RSEQCONT=1 (a.k.a. NASTRAN SYSTEM(357)=1) should cause Nastran to ignore all continuation fields. This is very advantageous when you have lots of input decks or pieces of decks coming from different sources. For the most part this feature works. However, in the case where this is an include file, for instance a file with only MAT8’s and the second row is missing (generally left out as it is often all zero) Nastran will issue a USER FATAL MESSAGE 4392. To message doesn’t list the MAT8. It will

Known Error

CR 1-45630951 indicate the problem is with the next entry it finds.. Avoidance: Explicitly enter the continuation entry as follows MAT8 1020009 2.0600+71.1300+6.340000 580000.00.0 0.0 .0 +000001 MAT8 1020014 1.0030+71.0000000.0 1.0000000.0 0.0 .0 +000003 needs to be changed to: MAT8 1020009 2.0600+71.1300+6.340000 580000.00.0 0.0 .0 +000001 +000001 0.0 0.0 MAT8 1020014 1.0030+71.0000000.0 1.0000000.0 0.0 .0 +000003

Known Error

CR 1-46023346

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Documentation/QRG - MONPNT3 error in QRG

Description

Remark 1 of MONPNT3 description in the Nastran QRG indicates that MONPNT3 is available for SOL 101, 144 and 146. This is incorrect, SOL 146 is not supported.

Known Error

CR 1-46027846

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract Description

SOL 700 - DYPARAM,LSDYNA,HOURGLASS is not effective. DYPARAM,LSDYNA,HOURGLASS to control hourglass is not effective in SOL 700. Avoidance: Use PARAM,DYHRGIHQ or DYHRGQH

Known Error

CR 1-46052877

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL 200 job Random response types may fail with SFM 3001

Description

SOL 200 job with DRESP1 with RTYPE=RMSXXXX or PSDXXXX will fail as shown below when one of the following conditions is met:

Known Error

CR 1-46052877 1. autoadj is set to no; 2. Any other condition that turns off Adjoint Method off. In particular, it is true for the above job that includes DVGRID entry that references grid point connecting rigid element such as RBE2 (3). Since Adjoint method is turned off when grid point connecting rigid element is being designed. *** SYSTEM FATAL MESSAGE 3001 (DSVG1) THE INPUT DATA BLOCK NAMED UG21 AT POSITION 8 DOES NOT EXIST. USER INFORMATION: THIS ERROR IS CAUSED BY ONE OF THE FOLLOWING: Avoidance: None.

Known Error

CR 1-46052930

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Optimization/Design Sensitivity - MFREQ with RANDOM - UWM 2071 (DPD2) In SOL 200, with MFREQ and RANDOM, after the 1st design cycle the following message is issued. This message appears to be superfluous and does not affect the answers:

Description

V2004 message *** USER WARNING MESSAGE 2071 (DPD2) DAREA SET 221 REFERENCED IN DYNAMIC LOAD RLOAD2 ENTRY 111 DEFINES NULL ENFORCED MOTION V2005 message *** USER WARNING MESSAGE 2071 (DPD2) EXCITATION SET 221 REFERENCED IN DYNAMIC LOAD RLOAD2 ENTRY 111 DEFINES NULL ENFORCED MOTION

Known Error

CR 1-46077402

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

External Superelements - EXTSEOUT - SFM 3200 BDYINF, Multiple SPC sets If EXTSEOUT is requested with multiple SPCs, then only the 1st set of SPCs will be used to generate KAA/PA and the following fatal message will be issued:

Description

*** SYSTEM FATAL MESSAGE 3200 (BDYINF) LOGIC ERROR 29 ENCOUNTERED IN SUBROUTINE BDYINF USER ACTION: REPORT THIS PROBLEM TO MSC CLIENT SUPPORT 0FATAL ERROR

Known Error

CR 1-46077402 Avoidance: Reduce each SPC set one at a time.: This error may occur for MPC sets.

Known Error

CR 1-46095441

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Description

SOL600 - BEAM SECT Error If Type=ROD of the pbarl/pbeaml is specified, the Effective transverse shear area (As) in the tranlated marc.dat input is wrong. The marc default is As=A, the nastran default is 0.857*A(K=0.857 for MDLPRM,TWBRBML,0) or 0.9*A(K=0.9 for MDLPRM,TWBRBML,1). The effective transverse shear area of marc.dat is 0.5*A. The effective transverse shear area for marc is not the reference area factor for shear(nastran) of the pbar/pbeam entry. If SOL600 data is K=0.9, marc.dat should be As=K*A=0.9*A. However, the effective transverse shear area of marc.dat is As=0.85*A.

Known Error

CR 1-46119514

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Nonlinear Analysis - MATS1 Kinematic hardening or Combined hardening Wrong Answers

Description

A SOL 106 quad4 model with MATS1 PLASTIC TABLES1 and von mises yield criteria with the kinematic hardening rule (HR=2 on MATS1) will report a maximum equivalent stress as the LIMIT1 (i.e., Y1 aka initial yield) even though the loading increases beyond yield. The combined hardening rule (HR=3) will continue to increase the equivalent stress, but it is not the same as Von Mises stress above the yield point. This error applies to all element types.

Known Error

CR 1-46245072

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Fluid Analysis - Wrong effective mass values with MFLUID and PARAM,VMOPT,2 Modal effective mass output will be wrong with PARAM,VMOPT,2

Description

Avoidance: Insert the following DMAP alter:

Known Error

CR 1-46245072 COMPILE MODEFSRS ALTER 'EFFMAS.*PHSA,LAMAS,'(,-1) IF ( VMOPT=2 AND NOCEE>0 ) THEN $ CALL MGEN1 GGE ,USET ,GM ,GOt ,goq , BEC ,CEE ,MEE ,MEC ,msaa / MEA ,MvAA / 0 /NOA /0 /false $ EQUIVX MvAA/MSAA/-1 ENDIF $

Known Error

CR 1-46342723

Product

MSC / MD Nastran

Corrected Version 2007.0.0 (MD R2) Abstract

External Superlement - SFM 4276 (FREAD) EC 3002, with large include file resourse issue This External superelement models with extremely large include files may fail with the message: *** SYSTEM FATAL MESSAGE 4276 (FREAD) ERROR CODE 3002 PID= 0

Description

This limitation was observed in Nastran 2005. In Nastran 2007 and checked again in Nastran 2010 the maximum size of include files has been increased. It is unknown what the new limit is. If this problem is encountered again, very large include file with superelements, please create a new CR and attache the files necessary to duplicate the problem.

Known Error

CR 1-46486346

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL 400 - BCPARA, FTYPE=6 - Core Dump by computing E8x97 Vol.E when FTYPE 6 is used

Description

SOL 400 with contact with FTYPE=6 (bilinear coulomb friction) specified on the BCPARA entry may fail with a traceback.

Known Error

CR 1-46507156

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

DBCMSG ERROR MESSAGE 22, SUBROUTINE ELMBLK - Missing quad4 element stress/strain in xdb

Description

The stress and strain output for quad4 elements may be missing from the xdb when CFAST elements are present. The message:

Known Error

CR 1-46507156 DBCMSG ERROR MESSAGE 22 FROM SUBROUTINE ELMBLK is a clue that this condition may exist. The element type in DBCEQE needs to be changed from 55 to 68 for FASTP.

Known Error

CR 1-46561555

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Description

Topology - CASI solver performance issue when TOPVAR bulk data is present SOL 101 SOLVIT module performance is adversely affected when the casi element-based iterative solver is selected and 1) the model contains a large number of 10-node TET elements to be processed in implicit mode (the SOLVIT default) 2) a TOPVAR bulk data entry is present that selects a PSOLID entry that is referenced by CTETRAs An avoidance is to remove the TOPVAR bulk data entries.

Known Error

CR 1-46581521

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Documentation/QRG - PARAM,AUTOMSET

Description

In QRG of MD 2006r1, the description of PARAM,AUTOMSET is "MD Nastran Implicit Nonlinear (SOL 600) only". The description for other supported solutions such as SOL 101, is missed.

Known Error

CR 1-46584431

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

SOL 600 - Multiple subcase SPCD Incorrectly Translated In multiple subcase, the enforced displacement of SPCD+SPC1 with SPC not translated correctly.

Description

For SOL 600 do not enter SPC or SPC1 for dof's where SPCD is specified. For the MD R2 and MSC.Nastran 2007 releases, if this is done the SPC or SPC1 will be placed before the SPCD at the same dof in the Marc input so it will be ignored.

Known Error

CR 1-46592824

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Aeroelastic Analysis - SOL 146 fails with UFM 5423 when several subcases are defined When several subcases are defined in SOL 146, Nastran fails with the message UFM 5423:

Description

*** USER FATAL MESSAGE 5423 (SADD5) ATTEMPT TO ADD INCOMPATIBLE MATRICES FILE# COLS ROWS FORM TYPE NZWD DENS TRAILER FOR SCRATCH IS 306 81 11 2 3 22 9877 TRAILER FOR PHF IS 110 162 11 2 4 0 0 0FATAL ERROR

Known Error

CR 1-46727939

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Optimization/Design Sensitivity - SFM 5423 (MPYAD1) ATTEMPT TO MULTIPLY INCOMPATIBLE MATRICES An optimizatoin job with a static SPCFORCE response may fail at MPYAD in subdmap RESPSEN with the following message:

Description

*** SYSTEM FATAL MESSAGE 5423 (MPYAD1) ATTEMPT TO MULTIPLY INCOMPATIBLE MATRICES FILE# COLS ROWS FORM TYPE NZWD DENS TRAILER FOR QG IS 101 2 36 2 2 8 1111 TRAILER FOR SPAWQ IS 102 16 1 2 2 2 10000 TRAILER FOR QG1X IS 103 16 36 2 2 4 174 TRANSPOSE FLAG IS 0 Avoidance: Insert the following DMAP alter: compile respsen alter 'diagonal spaw2'(,1),''(,4) dbview lcdvec0=lcdvec where(ncase=0) $ dbstatus lcdvec0//s,n,nolcdvec $ paraml lcdvec0//'trai'/6/s,n,density $

Known Error

CR 1-46727939 if ( nolcdvec>0 and density0) THEN $ EQUIVX LAMA/LAMA2/-1 $ ENDALTER $

Known Error

CR 1-47037011

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Description

Optimization/Design Sensitivity - TPL test d200pe7 UFM 4646 (REIG) TPL optimization test d200pe7 may produce an indefinite mass matrix on some machines and fail during the eigensolution with the following message: *** USER FATAL MESSAGE 4646 (REIG) THE MASS MATRIX INPUT TO THE REAL EIGENSOLVER IS INDEFINITE.

Known Error

CR 1-47123337

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

External Superelements - EXTSEOUT- Statics with TEMP(LOAD), OTM stresses incorrect in assembly In static analyis, for EXTSEOUT external superelements, the assembly run with TEMP(LOAD) will give incorrect results for Forces and Stresses on the external superelement. NOTE: The residual is correct and the displacements/spcforces on the external are correct. Avoidance: : Use PARAM,EXTDROUT and use the 3-step process to recover stresses in the upstream superelements.

Known Error

CR 1-47128492

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Matrix Methods - SMETHOD - SFM 4276 (unpack) ec 20 - casi solver When no loads are applied in a linear statics sol 101 run and the casi solver is requested (smethod = element) then the following error message appears in the f06:

Description

*** SYSTEM FATAL MESSAGE 4276 (UNPACK) ERROR CODE 20 PID= 0 and the job fails. A more meaningful message should be output.

Known Error

CR 1-47162343

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

DMP - DOMAINSOLVER STAT(PARTOPT=DOF) with SUPORT and INREL - SFM 4276 in MRGCOL SYSTEM FATAL MESSAGE 4276 in MRGCOL may be issued with SUPORT and interial relief if used with DMP. Avoidance:

Description

compile sekrrs alter '216'(,-1) return $ compile sestatic alter 'call phase1c','' IF ( nouset>0 and NOT(NONLNR) and ( (dbrcvx='scratch' and not(pardcmp)) or (pardcmp and hlpmethx=1 and procid=1) ) ) CALL PHASE1C KAA ,USET ,SILS ,EQEXINS ,maa , PA , , ,cases , , drg , , , / KLL ,LLL ,Dar ,ULL ,mr , mlr ,mll ,mrr ,QR ,PL , LRSEQ , , , , , / SEKR /SEMR /SELR /NOLSET /NORSET / true /ERROR /FIXEDB /NOQSET /NOTSET / ' '/TRUE /false /false /noa / false $ alter 'or mdstat','' if ( not(gmconv or pardcmp or NONLNR) ) then $ alter 'call statrs','' IF ( NOT(NOPH2) AND (NOLLL>0 OR GETSYS(NP,216)0 or mdstat) ) CALL STATRS LLL ,KLL ,PL ,GPLS ,USET , SILS ,QR ,MATPOOL ,EQEXINS ,DRG , Dar ,GM ,GOT , ,LRSEQ , EDTs ,CASES ,kgg ,kaa ,kelm , kdict ,bgpdts ,cstm ,mpts ,dit , est ,ys ,pg1 / UL ,CRX ,PRECON ,epssex ,qrg / IRES /INREL /LUSETS /NSKIP /NLOADS / NORSET /NOA /PVALOLD /ADPTINDX/PEXIST / s,nullsol $ compile statrs alter 'fbs '(2),''

Known Error

CR 1-47162343 call mdstat kll,pli,uset,sils,eqexins/ ul $ putsys(0,307) $ mergeofp=no -- deactivate distributed data recovery endalter

Known Error

CR 1-47165003

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Installation - Support for Windows Vista The Nastran Windows Installshield based installation does not recognize the Windows Vista operating system and will not allow the installation to continue.

Description Avoidance: The only avoidance is to install nastran on another machine and copy the installation to the Vista machine. Beyond the installation nastran has been certified on Windows. Known Error

CR 1-47167162

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Miscellaneous - Linux RHE 4.0 - No Time Information - time: error waiting MSC.Nastran or MD Nastran V2006.0.1 or ealier on linux, linux8664, or linux64 with the RHEL4 or SuSE 10 (or later) distribution, may have the following message in the log file: time: error waiting for child process: No child processes

Description The results of the analysis are correct. The timing information which is normally in the log file is not there though. Avoidance: Upgrade the "nastran" driver in $MSC_BASE/$MSC_VERSD/$MSC_ARCH to a newer version of Nastran. Known Error

CR 1-47218191

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Acoustics - PANEL PARTICIPATION FACTORS are not correct if a panel does not coupled with fluid

Description

ACOUSTIC PANEL PARTICIPATION FACTORS are not correct if one of panels does not coupled with fluid as shown below.

Known Error

CR 1-47218191 Example: 4 panels are defined and a panel named "bottom" does not coupled with fluid. Then PANEL RESPONSE of "bottom" should be zero, but it is not zero, and "top_right" does not appear. panel,bottom,2 panel,top_left,3 panel,top_cent,4 panel,top_righ,5 set1,2,16367,thru,16402 set1,3,16246,thru,16300 set1,4,16301,thru,16311 set1,5,16312,thru,16366

ACOUSTICPANELPARTICIPA TIONFACTORS GRID POINT = 37, TOTAL RESPONSE (R/I) = 3.05356E+00 / -5.16123E-03, (M/P) = 3.05357E+00 / 359.90 LOAD FREQUENCY = 1.00000E+00, (SUBCASE 1, DLOAD = 4) MAXIMUM PANEL RESP = 1.85680E+00 FOR PANEL = TOP_LEFT, SORTKEY = PANEL , SORT = ALPHANUMERIC , FILTER = 1.00000E-16 PANEL NAME PANEL RESPONSE PANEL RESPONSE PROJECTION REL. PANEL SCALED RESPONSE REAL IMAGINARY MAGNITUDE PHASE MAGNITUDE PHASE FRACTION MAGNITUDE BOTTOM 5.98452E-01 9.71956E-03 5.98531E-01 0.93 5.98435E-01 -358.97 1.95979E-01 3.22294E-01 TOP_CENT 5.98473E-01 9.71655E-03 5.98552E-01 0.93 5.98456E-01 -358.97 1.95986E-01 3.22305E-01 TOP_LEFT 1.85664E+00 -2.45973E-02 1.85680E+00 359.24 1.85668E+00 -0.66 6.08035E-01 9.99933E-01 Known Error

CR 1-47236346

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Acoustic Analysis - CACINF4 - External Acoustics may yield incorrect Panel Participation Factors

Description

External Acoustics may yield incorrect Panel Participation Factors

Known Error

CR 1-47319451

Known Error

CR 1-47319451

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

SOL 400 job will crash when elasto-plastic material MATEP is used without the associated MAT1 For elasto-plastic material data using MATEP in SOL 400, user needs to define both MATEP and MAT1. If only MATEP is defined then the job will crash in the TA1M module Avoidance: Please make sure that MAT1 is defined with the MID referenced by MATEP

Known Error

CR 1-47324010

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Optimization/Design Sensitivity - EXTSEOUT, ANAL=DFREQ or MFREQ - UFM 9104 If an external superelement is attached in a SOL 200 run with ANALYSIS=MFREQ or DFREQ then the job may fail with: ^^^ USER FATAL MESSAGE 9104 (SELR) ^^^ THERE IS NO COUPLING BETWEEN INTERIOR POINTS OF THIS SUPERELEMENT AND ITS BOUNDARY POINTS.

Description

Avoidance: Insert the following DMAP alter: compile feafreq alter 'sep2dr slist,emap','' sep2dr slist,emap// s,n,seid/s,n,peid/s,n,sedwn/s,n,lpflg///// s,n,noup/s,n,scndry/s,n,extrn//'all'//-1/ s,n,partse/s,n,setype/s,n,reid $ alter 'if ( seid\>0','' if ( seid>0 and not(extrn-1 or setype='extrna') ) then $

Known Error

CR 1-47446533

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Matrix Methods - DECOMP - signal number 10: bus error in Decomp

Description

Default changes to system 219 may cause models that ran in previous versions

Known Error

CR 1-47446533 to fail in DECOMP module with the message: Receiving signal number 10: Bus error Job aborting... Avoidances include: 1) set sys219=32 2) set sys206=10 3) increase memory. The recommendation would be to use the value from the UIM 4157: MEMORY REQR'D TO AVOID SPILL = 20228 K WORDS and increase it by at least 10%.

Known Error

CR 1-47649211

Product

MSC / MD Nastran

Corrected Version 2006.0.1 Abstract

Aeroelastic Analysis - UFM 6975 can be issued in error

Description

The nonlinear trim algorithm regards it as an error if a supported degree of freedom does not have any control surfaces that affect it. This is too stringent in that other free parameters in addition to control surfaces can control these degrees of freedom.

Known Error

CR 1-47688921

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Documentation/QRG - SOL 600 - PARAM,MARCSPCD does not work

Description

PARAM,MARCSPCD is documented in the QRG but is not supported. The documentation will be removed.

Known Error

CR 1-47711601

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Aeroelastic Flutter Analysis - Logic error in fa1pke When a singular mass matrix is used in flutter analysis, the job may fail with the message

Description

*** USER FATAL MESSAGE 3200 (FA1) LOGIC ERROR DETECTED BY SUBROUTINEFA1PKE 1 = LOCATE CODE OR VALUE.

Known Error

CR 1-47738693

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Nonlinear Transient Analysis - SE and CMS, NLTRD2 - SFM 1282 (SLCDRV) A nonlinear transient analysis with CMS fails in the NLTRD2 module with:

Description

*** SYSTEM FATAL MESSAGE 1282 (SLCDRV) AN ATTEMPT WAS MADE TO OPEN A NON EXISTENT ASSOCIATED FILE ULNTH ,FNUMERIC, TO READ. PROGRAMMER INFORMATION: CHECK THE NAME OF THE ASSOCIATED FILE TO OPEN. The same message appears when only CMS is used without the SE.

Known Error

CR 1-47826448

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

EXTSEOUT with DMIGPCH option may generate incomplete PLOTEL information in .pch file

Description

When EXTSEOUT is employed with the DMIGPCH option, the resulting .pch file may contain incomplete PLOTEL information. All PLOTELs that reference the highest numbered A-set grid point are ignored.

Known Error

CR 1-47879121

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Description

Matrix Methods - CASI Solver, TET10, TEMP(LOAD) - Incorrect stresses CASI solver temperature loads When TET10 elements are present in the input file, the default behavior of the casi solver is to use the "implicit" formulation for the element. This means that the element stiffness matrix is formulated internally by the casi software. The nastran generated stiffness matrices are not used for the TET10s. This is usually acceptable, unless the applied loads are element-based, as in this case, where temperature loads are used. Furthermore, in this case, in order to achieve stress-free thermal expansion, it is essential that the element stiffness and loads be compatible. Implicit element formulation should not be used. This can be achieved by placing a PARAM,ITOPTX,4032 entry in the bulk data section. Avoidance: insert PARAM,ITOPTX,4032 in the bulk data section to prevent

Known Error

CR 1-47879121 implicit TET10 usage.

Known Error

CR 1-47911501

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Documentatio/QRG - AUTOSPC describer - NOZERO vs. NONZERO

Description

References to "NONZERO' in the QRG description of the AUTOSPC case control command should be "NOZERO".

Known Error

CR 1-48031006

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Nonlinear Analysis - Using NSM in sol 106 or 400 causes SFM 3001 Using NSM in sol 106 or 400 results in the message:

Description

*** SYSTEM FATAL MESSAGE 3001 (TA1) THE OUTPUT DATA BLOCK IN POSITION 9 DOES NOT EXIST. USER INFORMATION: THIS ERROR IS CAUSED BY ONE OF THE FOLLOWING: 1. THE DATA BLOCK IS UNSPECIFIED ON THE DMAP MODULE. 2. THE DATA BLOCK IS SPECIFIED ON THE DMAP MODULE AND ON THE SUBDMAP STATEMENT BUT NOT ON THE CORRESPONDING CALL STATEMENT. Avoidance: Use the following alter. compile phase1a alter ' ta1 ','' TA1 MPTS,ECTS,EPTS,BGPDTS,SILS,ETT,CSTMS,DIT,,/ EST,ESTNL,GEI,GPECT,ESTL,vgfd,ditid,nfdict,nsmest/ LUSETS/S,N,NOESTL/S,N,NOSIMP/2/S,N,NOGENL/SEID/ LGDISP0/NLAYERx/s,n,freqdeps/shldamp/s,n,mge/nsm $

Known Error

CR 1-48240611

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Description

Frequency Response - Wrong Answers (SOL 108 and 111) with K4 & TFL, and Multiple Subcases Wrong answers will result in SOL 108 or SOL 111 when structural damping (K4) is combined with transfer functions. Avoidance: use the following DMAP alter:

Known Error

CR 1-48240611 compile sedfreq alter 'EQUIVX.*K4AA\/K4DD',''(,1) alter 'call gma'(,-1) EQUIVX K4AA/K4DD/NOUE $ IF ( NOUE>-1 ) UMERGE1 USETD,K4AA,,,/K4DD/'D'/'A' $ compile semfreq alter 'EQUIVX.*K4AA\/K4DD',''(,1) alter 'call gma'(,-1) EQUIVX K4AA/K4DD/NOUE $ IF ( NOUE>-1 ) UMERGE1 USETD,K4AA,,,/K4DD/'D'/'A' $

Known Error

CR 1-48291201

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Description

Documentation/QRG - Aeroelastic Analysis - aedw, aepress, aeforce do not support MACH=0.0 The Quick Reference Guide specifies that the MACH input must be .ge. 0.0, but if the user sets this input to 0.0, is is marked as an illegal data. Avoidance: The MACH must be set to a number .gt. 0.0

Known Error

CR 1-48291704

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

MDACMS - SDAMPING - Wrong Answers with K4 Structural Damping

Description

Modal Frequency response (SOL 111) with MDACMS may produce wrong answers with structral (K4) damping. Avoidance: The workaround is to include PARAM,MDK4OPT,0

Known Error

CR 1-48326271

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Description

MDACMS - SOLs 111 and 112 with Enforced Motion fails with PARAM,ENFMETH,ABS MDACMS in SOLs 111 and 112 with Enforced Motion fails with PARAM,ENFMETH,ABS. The following message may be issued: SYSTEM FATAL MESSAGE 5423 (MPYAD1) ATTEMPT TO MULTIPLY INCOMPATIBLE MATRICES

Known Error

CR 1-48326271 FILE# COLS ROWS FORM TYPE NZWD DENS TRAILER FOR MHS1 IS 101 26 30 2 2 60 4615 TRAILER FOR ACCE IS 102 202 1 2 2 2 10000 TRAILER FOR (NONE) IS 0 0 0 0000 TRANSPOSE FLAG IS 0 Avoidance: Insert the following DMAP alter: compile getpyh alter 'call xADD5.*mhs','mpyad.*khs1,disp,pmbh'(,1) equivx yst/disp/-1 $ call xADD5 mhs,m2hs,,,/mhs1/cu/cu/cz/cz/cz $ call xADD5 Bhs,B2hs,,,/Bhs1/cu/cu/cz/cz/cz $ c1g=CMPLX(1.,G) $ CALL xADD5 Khs,K4hs,K2hs,kdhs,/Khs1/C1G/ci/cu/cu/cz $ else $ $ transient response dsar yst,,,/disp,velo,acce,,/-1 $ call xADD5 BHS,B2HS,,,/BHS1/cu/cu/cu/cz/cz $ call xADD5 KHS,K2HS,kdhs,,/KHS1/cu/cu/cu/cz/cz $ call xADD5 mhs,m2hs,,,/mhs1/cu/cu/cz/cz/cz $ endif $ app='freqresp' $ if ( enfmeth='abs' and nonzys>-1 ) then $ partn bhs1,nzys,/,,bhs2,/1 $ partn mhs1,nzys,/,,mhs2,/1 $ partn khs1,nzys,/,,khs2,/1 $ mpyad mhs2,acce, /pmh $ mpyad bhs2,velo,pmh/pmbh $ mpyad khs2,disp,pmbh/pyxt $ else $ mpyad mhs1,acce, /pmh $ mpyad bhs1,velo,pmh/pmbh $ mpyad khs1,disp,pmbh/pyxt $ endif $

Known Error

CR 1-48629874

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Modal Participation Factors - PFMODE - SFM 4276 (PFCALC)

Description

Jobs using the PFMODE case control command may fail in the PFCALC module

Known Error

CR 1-48629874 with a SFM 3007 illegal input into mpyad message or a GINO message trying to open a matrix data block if any grid point resequencing has taken place and the internal grid point order is no longer in external sort. This can occur during superelement processing for example. There is no known avoidance.

*** SYSTEM FATAL MESSAGE 4276 (QOPEN) ERROR CODE 1044 PID= 0 *** USER INFORMATION MESSAGE 4276 (QOPEN) THE DIAG 44 RELATED A NASTRAN DUMP IS SENT TO LOG FILE. Traceback: Offset 0x00000110 in procedure gtdens_ Offset 0x00000108 in procedure mpyad_ Offset 0x000002a4 in procedure mpyadk_ Offset 0x000022cc in procedure pfcalc_ Offset 0x000005ec in procedure xsem07_ Offset 0x00000190 in procedure xsemdr_ Offset 0x00000064 in procedure nastmon_ Offset 0x00000adc in procedure mainal --- End of call chain --Known Error

CR 1-48865131

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Aeroelastic Analysis - SOL 145 may fail if MONPNT is in the deck SOL 145 does not support MONPNT. However, SOL 145 job may fail if MONPNT is simply in the deck.

Description Avoidance: 1. remove or comment out MONPNT entry 2. use attached DMAP alters (add dmonpta/dmonpts to call of SUPER1) Known Error

CR 1-48873671

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Aeroelastic Analysis - infinite loop in sol 144

Description

If a Solution 144 (static aeroelasticity) run is submitted that does not have any TRIM or DIVERG case control commands in any of the subcases, an infinite loop will result in the PFAERO subdmap. Avoidance: Make sure the required TRIM and DIVERG case control

Known Error

CR 1-48873671 commands are included in case control

Known Error

CR 1-48879511

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Miscellaneous - ISHELL jobs terminate abnormally when run using a job scheduler

Description

If Nastran starts an ISHELL job that is suspended by a job scheduler (using a "kill -STOP"), the ISHELL processing routine (doit.c) does not properly recognize this situation and terminates processing with an error.

Known Error

CR 1-48996563

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

SOL 600 - BCBODY - Friction not written correctly, Wrong Answers

Description

The marc CONTACT entry is not written correctly when the BCBODY entry contains a friction coefficient.

Known Error

CR 1-49035502

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

External Superelement - ACMS, ASSIGN OUTPUT2 - segmentation fault If DMIGOP2 is specified on EXTSEOUT and UNIT>100 on the ASSIGN OUTPUT2 and DOMAINSOLVER ACMS is being used then the run may fail with a segmentation fault on AIX mode=i8 only. Avoidance: Specify output2 unit number less than or equal to 100.

Known Error

CR 1-49085732

Product

MSC / MD Nastran

Corrected Version 2006.0.1 Abstract

Elements - PBMSECT - Stress recovery of arbitrary beam elements may fail

Description

Stress data recovery of abitrary beam elements may enter an infinite loop if a FORCE Case Control command is not present.

Known Error

CR 1-49086447

Product

MSC / MD Nastran

Known Error

CR 1-49086447

Corrected Version 2007.0.0 Abstract

Docuementation/QRG - Remark 12 for ASSIGN statement. The following limitation documented in remark 12 of the QRG for the ASSIGN statement was removed in V2005.5.

Description

"Note, however, that the DBLOAD and INPUTT2 modules cannot process input files in other than the native binary format. That is, a binary file in BIGNENDIAN format cannot be processed on a LITTLEENDIAN platform and vice-versa". The MD R2 and MSC.Nastran 2007 QRG has been updated.

Known Error

CR 1-49098315

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Rotordynamics - Hybrid Damping in Rotordynamics SOL 107 or 108 w/ no SE - SFM 3001 (GKAM) A rotordynamics model with hybrid damping and no superelements fails in the call to the READ module in subDMAP HYBRID with the message:

Description

*** SYSTEM FATAL MESSAGE 3001 (GKAM) THE INPUT DATA BLOCK IN POSITION 4 DOES NOT EXIST. USER INFORMATION: THIS ERROR IS CAUSED BY ONE OF THE FOLLOWING: 1. THE DATA BLOCK IS UNSPECIFIED ON THE DMAP MODULE. 2. THE DATA BLOCK IS SPECIFIED ON THE DMAP MODULE AND ON THE SUBDMAP STATEMENT BUT NOT ON THE CORRESPONDING CALL STATEMENT.

Known Error

CR 1-49118561

Product

MSC / MD Nastran

Corrected Version 2010.1.1 Abstract

Utilities - Acounting does not work in MD Nastran (acct=yes)

Description

Acounting does not work in MD Nastran (acct=yes). It does work in MSC.Nastran 2005r3.

Known Error

CR 1-49161431

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3)

Known Error

CR 1-49161431

Abstract

Performance - TAUCS - ILP64 (linux64 / linux8664) If TAUCS (sys166=8192) is used on ILP64 systems, then the perfomance is very bad.

Description

Avoidance: - Run without TAUCS - Create a BLAS shared object containing SSYRK and STRSM and use BLASLIB=New_Blas_lib.so - fixed in MDR3 on x8664 and IA64 ILP64 systems.

Known Error

CR 1-49381161

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract Description

SOL 700 - EOSGAM entry error EOSGAM entry gives the following FATAL ERROR : Illegal name for bulk data entry. Avoidance : Use the TODYNA- ENDDYNA entry to bypass this entry.

Known Error

CR 1-49477782

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Elements - PCOMP Z0 vs ZOFFS, Unsymmetric Layups - Slightly different answers

Description

A stiffness change was made for CQUAD4 and CTRIA3 elements that reference a PCOMP if the membrane coupling (MID4) is nonzero. Usually MID4 is nonzero due to offset, but is also nonzero in non symmetric composite layups. The differences are attributed to a small difference in the way the transverse shear stiffness is calculated. The prior element behavior may be selected by setting system(451)=1.

Known Error

CR 1-49495686

Product

MSC / MD Nastran

Corrected Version 2007.0.3 Abstract

Rotordynamics - SOL 108 or 129, RSDAMP - Hybrid Damping READ Module, UFM 4683 A 3D rotordynamics model fails in the READ module with the following error

Description

*** USER FATAL MESSAGE 4683 (REIG) MASS MATRIX NEEDED FOR EIGENVALUE ANALYSIS

Known Error

CR 1-49495686 when hybrid damping is requested in the case control with RSDAMP command. Quality 1-49098315 may be related since it is a similar setup but without a superelement.

Known Error

CR 1-49496581

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

Description

Aeroelastic Analysis - IFP - AECOMP with a continuation with data in field 9 cause an IFP error The AECOMP entry supports an open-ended list of set ids for the component. If the list of set id's ends with the 9th field of a continuation entry (i.e., there are exactly 14, 23,32, etc. ID's) the job will fail with an invalid data message. Avoidance: The AECOMPL entry can be used to collect multiple AECOMPs so this provides a way to avoid the above liimitation.

Known Error

CR 1-49502651

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

ADAMS Integration - SPOINT/QSETi - SFM 7624(GKAM) in stress recovery run The following message occurs in stress recovery, when the number of SPOINT/QSETi are specified greater than needed in MNF file creation run.

Description

*** SYSTEM FATAL MESSAGE 7624 (GKAM) THE NUMBER OF EIGENVECTORS ( 42) IN THE PHSA MATRIX IS GREATER THAN THE NUMBER ( 38) OF COMPUTED EIGENVALUES IN THE LAMMATS MATRIX Avoidance: Set same values for SPOINT/QSETi.

Known Error

CR 1-49509805

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

SSSALTER - glforce alter gives incorrect results

Known Error

CR 1-49509805

Description

MSC.Nastran Version 2004 and 2005 versions of the glforce alter give incorrect answers. In the previous versions KAA was called up with a type,db statement. In 2004 and 2005 KAA is in the datablock list for the subroutine but not in the called datablocks. This produces a null datablock and hence incorrect results.

Known Error

CR 1-49522526

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Documentation/QRG - EPOINT documentation error

Description

The Quick Reference Guide indicates that there is a ID limit of ID0)','' $ SELIST=(auxmid0) $ COMPILE phase1dr alter 'SEP2DR SLIST' $ if ( auxmid>0 ) noup = -1 $ alter 'IF ( NOKAA','' $ if( nokaa1 ) then $ and use the following DMAP alter for 2007: compile EXTIN $ alter 'if ( nouset','' if ( nouset>0 and not(exter) ) then $ COMPILE spdr1 alter 'PEID=SEID' $ type parm,,i,n,np2 $ type parm,nddl,i,n,desiter $ np2 = desiter $ if ( peid>0 ) desiter = 0 $ alter 'NOASET=LUSETS' $ if ( peid>0 ) desiter = np2 $ COMPILE phase0 alter 'SELIST=(NOSELIST>0)','' $ SELIST=(auxmid0) $ COMPILE phase1dr alter 'SEP2DR SLIST' $ if ( auxmid>0 ) noup = -1 $ alter 'IF ( NOKAA','' $ if( nokaa1 ) then $

Known Error

CR 1-51517141

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Documentation/QRG - PSOLID - TETRA(5-10 node) supported in SOL 106, 129 and 400

Description

In Table 8-43 at the end of the PSOLID description in the Quick Reference Guide it incorrectly indicates that the TETRA 5-10 is not supported in SOL 106, 129 and 400.

Known Error

CR 1-51544187

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Connector Elements - CWELD - UFM 6599 (SEP1C), CWELD with ELEMID, Superelements

Description

When the PWELD entry specifies that MSET is on, USER FATAL MESSAGE 6599 (SEP1C) may be incorrectly output. .

Known Error

CR 1-51552281

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

SOL 600 w/ COORD SYSTEMS - DDM - Parallel does not work This is a Marc limitiation. In order to add coord sys capability for CBUSH and cylindrical/spherical system MCID's the new Marc COORD SYS option needed to be used. For models without CBUSH coordinate orientation or MCID's specified by a coordinate, enter the following parameters PARAM,MRCOORDS,1 PARAM,MRORINTS,1 Starting with tier 1 systems as of 6/22/2007 the above will happen automatically. E Dickerson 6/22/2007 Starting with MD R2, SOL 600 analyses with COORD SYSTEMS will not run parallel. Avoidance: Convert local coordinate systems to the global coordinate system.

Known Error

CR 1-51564461

Product

MSC / MD Nastran

Known Error

CR 1-51564461

Corrected Version 2007.1.0 Abstract

Aeroelastic Analysis - AERODYNAMIC FORCE Output, Incorrect Element ID The aerodynamic force table can sometimes have a 0 as the element ID in the last row of data rather than the highest aerodynamic element ID.

Description User Information: the missing id is confined to the printout and does not affect any other output. Known Error

CR 1-51589547

Product

MSC / MD Nastran

Corrected Version 2007.0.0 Abstract

SOL 600 - MSC_LICENSE_DISCRETE - Nastran Tokens/ALUs are not released before marc is executed When running an MD R1 Nastran or MSC.Nastran 2005r3, SOL600 job with MSC_LICENSE_DISCRETE set to 1, then Nastran doesn't release licenses. The next table shows MD Nastran token usage for a SOL600 job: Application Normal Discrete

Description

MD Nastran 288 288 Translator 334 334 Marc 184 518 MD Nastran 288 518 Translator 334 518 As you can see with MSC_LICENSE_DISCRETE=1 , most of the time 518 tokens are checked out! (this represents 518 tokens * Euro 400 = Euro 200,000 !!!!! (so more than 200K US$ ))

Known Error

CR 1-51706467

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Rotordynamics - SOL 109, Module ROTRUTL, SFM 4276, EC 3001 A linear transient solution, SOL 109, fails with the following message for version MD R2 (aka 2007) but runs successfully with MSC.Nastran 2005r3b.

Description

*** SYSTEM FATAL MESSAGE 4276 (FREAD) ERROR CODE 3001 PID= 0 The failure occurs because there are no RSPINTs entries defined. The interpretation

Known Error

CR 1-51706467 of this should be that the rotors do not spin.

Known Error

CR 1-51854251

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Acoustic Analysis - Grid Point Participation Factor - wrong grid id in punch file Grid IDs in the punch file of an acoustic analysis with grid point participation factor requests will have a value of "4" appended to the end.

Description

The error happens when only the punch file is requested by case control command disp(punch). Avoidance: Request disp(print,punch).

Known Error

CR 1-51861461

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Restarts/External Superelements - EXTSEOUT(DMIGPCH) - Wrong Answers A SOL 111 restart from a previous sol 111 job which contains an external SE created with EXTSEOUT(DMIGPCH) produces incorrect results when K2GG and M2GG have been omitted in the restart. The results are the same as for the cold start. This happens because KAA is available from the restart database.

Description Avoidance: Add the following to the restart run to delete the external SE: begin super /,1,99999999 Known Error

CR 1-51884991

Product

MSC / MD Nastran

Corrected Version

2007.0.1

Abstract

SOL 600 - Certain shell elements with MCID using new COORD SYS option Missing orientation vectors

Description

Certain shell elements with MCID using the new COORD SYS option are missing orientation vectors in the Marc deck in MDR2. See external web: MD R2 update for HPUX IA64 http://www.mscsoftware.com/support/software_updates/index.cfm#nastran

Known Error

CR 1-51919711

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Frequency Response - FRF run with an RLOAD1 entry with null excitation fails with SFM 3200 in DPD

Description

An FRF generation run with an RLOAD1 entry with null excitation will fail with SFM 3200 (Logic error 14) in subroutine DPD9 in the DPD module.

Known Error

CR 1-51942339

Product

MSC / MD Nastran

Corrected Version 2007.0.2 Abstract

SOL 600 - CONM, GRAVi - PARAM,WTMASS multiplier is ignored for conm and density for gravity

Description

PARAM,WTMASS multiplier is ignored for conm and mass density used in gravity loading in SOL 600.

Known Error

CR 1-51945401

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Documetation/IOG - FFIO - New Selection Method Starting with MSC Nastran 2007.0.0 R1 FFIO is no longer selected by setting only FF_IO_OPTS. The addtional new setting is also required: LD_PRELOAD=$MSC_BASE/$MSC_VERSD/linux64/libFFIO.so for example:

Description

export LD_PRELOAD=/opt/msc/msc2007/linux64/libFFIO.so This change will allow FFIO libraries to be dynamically set. Note that the msc2007.0.0 R1 shared object has been tested on ProPack 4 and ProPack 5. It does not work with ProPack 3.

Known Error

CR 1-51995261

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SOL 400 - Incorrect Message, UFM 4512

Description

If there is an error for the NLPARM ID for SOL 400, module ST2DYN give UFM 4512, which is for the DEFORM entry.

Known Error

CR 1-52043741

Product

MSC / MD Nastran

Known Error

CR 1-52043741

Corrected Version 2007.0.2 Abstract

SOL 600 - Tables in large field format may not be correct or may be missing

Description

SOL 600 may incorrectly translated table entries that input in large field format or may fail to translate them at all.

Known Error

CR 1-52044231

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Optimization/Design Sensitivity - sensitivity descrepancy between dresp1 and dresp2 The frequency response sensitivity for the following DRESP1 with RSS should have an identical value and sensitivity with its derived DRESP2 entry when there is a single forcing frequency. dresp1 10001 pres PRES 1 RSS 1001

Description

dresp1 10002 pres PRES 1 RSS 1021

The above statement is not true for cases with very small response value, -1 ) then $

Known Error

CR 1-52459991

Product

MSC / MD Nastran

Corrected Version 2007.0.2 Abstract

Documentation/QRG - SOL 600 - DMIGOUT - Incorrect Default values The default value of "1" for the DMIGOUT-ICTRL, IFREQ and ICORD as shown in the QRG(MD Nastran R2) is incorrect. The correct default value is 2, 1 and 2 respectively for these fields.

ICTRL Controls type of matrix. (Integer; Default = 2) 1=element matrices 2=global matrices 3=element and global matrices Description

IFREQ Controls how often the matrices are output (Integer; Default = 1) 1=output at every increment 2=output every other increment, etc. -1=output only at end of the subcase. ICORD Controls matrix output coordinate system (Integer; Default = 2) 1=Nastran basic coordinate system 2=current transformed coordinate system (at the start of the run, this is the Nastran global coordinate system).

Known Error

CR 1-52650292

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Linear Contact - BCONTACT - Wrong Answers

Description

Linear contact may lead to incorrect results.

Known Error

CR 1-52650292 Avoidance: Too rigorous convergence criteria may lead to false results or divergence. Set the CONV field of the NLPARM entry to P instead of its default, UPW.

Known Error

CR 1-52657971

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

DMP - SuSE 10 / IA64 - mpirun: Bad address Some, but not all, SuSE 10 IA64 systems get an error while running DMP: mpirun: Bad address

Description

It is unknown what specific configuration or package causes this error. Avoidance: - Upgrade to MD 2007 and use either HP/MPI ("proc=hp hpmpi=yes" on the command line) or Intel/MPI ("proc=intel intelmpi=yes"). - Use MD R2.1

Known Error

CR 1-52721371

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

DMP/Frequency Response - DOMAINSOLVER, PARAM,LFREQ - UFM 3047 (GKAM) Use of PARAM,LFREQ in a DMP modal frequency response analysis may result in the fatal message:

Description

*** USER FATAL MESSAGE 3047 (GKAM) NO MODES HAVE BEEN SELECTED FOR USE IN THE ANALYSIS. THEREFORE A MODAL FORMULATION CANNOT BE MADE. 0FATAL ERROR

Known Error

CR 1-52721829

Product

MSC / MD Nastran

Corrected Version GL Abstract

Eigenvalue Analysis - WEIGHTCHECK(SET=(G,A))=YES and PARAM,MHRED,YES - Wrong answers

Description

If PARAM,MHRED,YES is active then the WEIGHTCHECK printout for the Aset will show a reduction in mass from the G-set printout. But this will not affect the subsequent results in the run or in a subsequent restart.

Known Error

CR 1-52721829 Avoidance: Insert PARAM,MHRED,NO.

Known Error

CR 1-52750618

Product

MSC / MD Nastran

Corrected Version 2007.0.2 Abstract

Elements - PBUSHT and PBUSH with the same ID, Unexpected Answers

Description

No errors are produced if PBUSHT and PBUSH with the same ID are entered. When this happens, the PBUSH entry can wipe out the intended PBUSHT entry and produce incorrect results.

Known Error

CR 1-52791051

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Composites - PCOMP, PARAM,POST,0 - Missing data in XDB

Description

Layered composite stress results may be missing from the xdb for SOL 106.

Known Error

CR 1-52819821

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Miscellaneous - Incorrect ReplicatorSymbol lead to UFM307 ILLEGAL NAME FOR BULK DATA ENTRY úÿÿÿ When using the record replicator an input of a "-" instead of an "=" lead to the fatal message:

Description

USER FATAL MESSAGE 307 (IFPDRV) ILLEGAL NAME FOR BULK DATA ENTRY úÿÿÿ which made it difficult to find the actual input error.

Known Error

CR 1-52841658

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Modal Participation Factor - PFMODE - Missing Output

Description

Modal participation factor (PFMODE) is not output when even one meaningless direction is specified. For example, if there is no response in the T1 and the T2 direction and a set references either as shown below, the participation factor for the T3 direction will not be output.

Known Error

CR 1-52841658 $ structure gird set 2 = 105/T3, 104/T1 $ not ok $set 2 = 104/T1 $ not ok $set 2 = 104/T3 $ ok $set 2 = 105/T3, 104/T3 $ ok $ fluid grid set 3 = 1020, 1021, 1022 pfmode(structmp=all) = 2

Known Error

CR 1-52953651

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SOL 400 - GPFORCE, CQUADR, CTRIAR - Incorrect GPFORCES

Description

In SOL 400, the GPFORCE outputs computed for the nonlinear analysis are wrong. Any deck with GPFORCE output request for QUADR and/or TRIAR in SOL 400 will show that the GPFORCEs are not balanced.

Known Error

CR 1-53071681

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Element Strain Energy - OFREQ - Wrong Frequencies Output

Description

A memory overrun processing the OFREQ list may result in incorrect frequencies beign out and/or strange characters in the output.

Known Error

CR 1-53072087

Product

MSC / MD Nastran

Corrected Version 2010.1.1 Abstract

An assembly run of a static AESO job fails with UFM4574 in SDR1

Description

In v2007, a static AESO job may fail in the assembly run with the following message: *** USER FATAL MESSAGE 4574 (SDR1) DATA RECOVERY STARTED BUT NO DISPLACEMENT VECTORS AVAILABLE Avoidace: Turn off the AESO option by setting autose = 0 on the DOPTPRM entry.

Known Error

CR 1-53135565

Product

MSC / MD Nastran

Corrected Version 2007.1.0

Known Error

CR 1-53135565

Abstract

MODE=I8 - OUTPUT4, INPUTT4 - SFM 6445 (INPTX4) on ILP64(mode=i8) INPUTT4 may fail on i8 systems with the following message:

Description

*** SYSTEM FATAL MESSAGE 6445 (INPTX4) READ REQUESTED RETURNED INCORECT DATA LENGTH WHILE PROCESSING UNIT = 49 FOR LOGICAL NAME INPUTT4 EXPECTED 156 WORDS, ACTUALLY READ 78 WORDS USER ACTION: VERIFY THE FILE ASSIGNMENT AND CONTENTS OR CONTACT MSC.SOFTWARE CLIENT SUPPORT.

Known Error

CR 1-53159901

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Numeric Methods - Decomp, SOLVE, SYSTEM(166)=8192 - TAUCS Solver may crash I can get xx0rst0 to crash. That is VVPR 1-60306461. Other jobs now work though, So I will mark this as verified... jjg3/21/08

Description

There have been many fixes imported since this original report, and I have not been able to get the solver to crash in R3. I am marking this as fixed. ...trk

If the TAUCS solver is selected by setting SYS166=8192, then an analysis may crash. Avoidance: Do not use taucs. Known Error

CR 1-53172511

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Description

DBC - PARAM,POST,0 - DBC Module GPSTRAIN, STRFIELD, Access Violation (Signal 11) A model requesting STRFIELD=ALL and GPSTRAIN=ALL fails in the DBC module with an access violation during data recovery of the superelements. Avoidance: Remove the STRFIELD request.

Known Error

CR 1-53345233

Known Error

CR 1-53345233

Product

MSC / MD Nastran

Corrected Version 2007.0.2 Abstract

SOL 600 - NLAUTO - Loads not translated correctly.

Description

This example has the final time specified using NLAUTO. For SOL 600 dynamics problems, the fianl time is goverened by a combination of TSTEPNL and TABLED1 entries, any final time specified by NLAUTO is ignored. This also applies to the intial time step. For SOL 600 dyanmics, most other entries specified on NLAUTO are used with the exception of NRECYC, IDTAB, DAMP, IDMPFLG adn IPHYS. For statics, the initial time step and final time from NLAUTO overrides that provided by NLPARM. The QRG will be revised to clarify this situation. For the attachments provided, using the MD R3 released version, the Marc input decks correctly reflect the philosophy used in SOL 600 - E Dickerson 7/11/2008 Patran 2006 created a SOL 600 input deck that contains NLAUTO and TSTEPNL cards that span the same time. Whent the job is submitted, the point load is not properly translated into the MARC input deck. It only has a point load list that are numerical zeroes. It does not creat the second list showing the full load. Avoidance: NLAUTO should not be used. Manually changing the number of increments in the TSTEPNL from 100 to 101, the MARC deck is translated with both lists of point loads.

Known Error

CR 1-53351439

Product

MSC / MD Nastran

Corrected Version Abstract

SOL 109, Rotordynamics, TSTEP with Continuation In SOL 109, a TSTEP entry with a continuation may fail with the following message:

Description

*** SYSTEM FATAL MESSAGE 2090 (TRD1) TABLE DICTIONARY ENTRY 979 IS MISSING. 0FATAL ERROR

Known Error

CR 1-53444861

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SOL 400 - CQUADR, CTRIAR, PCOMP - Layer strains/stresses are wrong for

Known Error

CR 1-53444861 composites in SOL 400

Description

The layer stresses and strains computed for composite QUADR/TRIAR are wrong in SOL 400.

Known Error

CR 1-53562418

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Single and Multipoint Constraints - PARAM,AUTOMSET - SFM 4276, EC (bldpk) in GP4 Conflicts between an independent or dependent set membership of dofs can lead to the following error message:

Description

*** SYSTEM FATAL MESSAGE 4276 (BLDPRD) ERROR CODE 211 PID= 0 when param,automset,yes is being used. Avoidance: Omitting this parameter can help in finding the problem.

Known Error

CR 1-53658793

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Description

GPSTRAIN - Missing GPSTRAIN Output for Model with QUAD and HEXA Elements The Z1 and Z2 strain output is missing from the output of a model with QUAD4 or QUADR and a HEXA element is present. However the MID and CURV results are output. Removing the HEXA element allows the Z1, Z2 and MID results to be output. A model with only QUADR elements using cylindrical coordinates demonstrates similar symptoms to the QUADR/HEXA model, i.e., only MID and CURV output is obtained. Avoidance: The STRAIN request set must be limited to shell elements and then GPSTRAIN=ALL will provide the correct results for the FIBRE option in the surface declaration, otherwise nastran only provides MID and CURV strain output. We have confirmed this on multiple models.

Known Error

CR 1-53723270

Known Error

CR 1-53723270

Product

MSC / MD Nastran

Corrected Version 2007.0.1 Abstract

ADAMSMNF - Missing mnf file on AIX MD Nastran R2 and MSC.Nastran 2007r1 contain an error on AIX platform which for some variations of the ADAMSMNF case control command results in no mnf output and the following messages:

Description

*** USER FATAL MESSAGE 7811 (MNF_Error) *** SYSTEM WARNING MESSAGE 7810 (AFERRM) The known variation of the ADAMSMNF command that causes the error includes the keywords FLEXONLY and MINVAR. This problem has been corrected in Version 2007.0.2 and subsequent releases. Avoidance: Avoid these keywords.

Known Error

CR 1-53795821

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Connection Elements - CWELD, SWLDPRM - PROJTOL is not recognized for CWELD with MSET=ON

Description

The projection tolerance parameter PROJTOL specified on the SWLDPRM Bulk Data entry is not recognized for CWELD elements with MSET=ON option.

Known Error

CR 1-53832781

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SOL 400 - UFM 1126 with scr=post in tpl decks nltsr03 and nltsub03

Description

If scr=post (or scr=no with NASTRAN SYSTEM(316)=7 or 19), then SOL 400 may fail with USER FATAL MESSAGE 1126. Avoidance: There is no simple avoidance.

Known Error

CR 1-53887611

Product

MSC / MD Nastran

Corrected Version GL

Known Error

CR 1-53887611

Abstract

DMP/Eigenvalue Analysis - SFM 3034 in Lanczos Lanczos sometimes has a problems detecting rank-deficient sets of Lanczos vectors and this may lead to the folloiwng fatal message:

Description Avoidance: Not running dmp or setting system(166)=48 may avoid the problem. Known Error

CR 1-53894031

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Elements - CBEAM3 - Stress recovery for cbeam3 referencing pbmsect may fail in SDR2 or GPSTRPBX Full stress recovery for CBEAM3 element referencing PBMSECT entry with isotropic or composite material, may fail in SDR2 or GPSTRPBX module.

Description Avoidance : If possible, turn off full stress recovery by removing 'param,arbmss,yes' in the input deck. Known Error

CR 1-53923901

Product

MSC / MD Nastran

Corrected Version 2007.0.0 (MD R2) Abstract

External Superelements - k4 , unsymmetric matrix - Inefficient runtime In version 2005.5, if an external superelement is used in an acoustic cabin analysis, and element structural damping is included in the reduction run, the k4 matrix may be generated as unsymmetric which may cause substantial increase in the runtime.

Description

Avoidance: Add the following alter in the assembly run. COMPILE EXTIN NOLIST $ ALTER 'EQUIVX.*X\_K4' MODTRL K4XX////6 $ ENDALTER $

Known Error

CR 1-53986469

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Eigenvalue Analysis - READ - Access Violation or Signal 11

Description

A dense large mass matrix (~95000 dof and 0.5 dense) will cause the default

Known Error

CR 1-53986469 ordering method to encounter an access violation on PC Windows 32 bit systems and a Signal 11 on unix system. Avoidance: Use NASTRAN SYSTEM(206)=132 in the input file or sys206=132 on the command line as an optional keyword.

Known Error

CR 1-54149209

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Connection Elements - CFAST, CWELD - Bad TBEmatrix if all three GS, GA, and GB are specified

Description

If GS, GA, and GB are all specified on the CFAST or CWELD elements a bad TBE matrix occurs. In future releases GS will be ignored if GA and GB are specified.

Known Error

CR 1-54228489

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Composites - PLCOMP, PCOMPLS - Blank DIRECT field causes entire bulk data entry to be ignored

Description

If the DIRECT field on the PLCOMP or PCOMPLS bulk data entry is BLANK, then the entire entry is ignored. .

Known Error

CR 1-54239221

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SOL 400 - RBE and no differential may lead to SFM 7620 (EMG)

Description

In SOL 400, if there are kinematic elements (RBEs) and the differential stiffness is not required to be updated, SYSTEM FATAL MESSAGE 7620 will be issued by the EMG module.

Known Error

CR 1-54248591

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Documentation/QRG - MATF format incorrect for SOL 600

Description

The MD R2 QRG failed to update the MATF entry for fields that are relevant to SOL 600.

Known Error

CR 1-54248591 Avoidance: Please refer to the MD R2 Release Guide or MD R3 QRG.

Known Error

CR 1-54255321

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

MDACMS - DOMAINSOLVER, EXTSEOUT and CSETi causes SFM 5423 (MPYAD1) An MDACMS analysis with external superelements and CSETi (or BNDFREEi) will fail with SYSTEM FATAL MESSAGE 5423 (MPYAD1) Avoidance: Insert the following DMAP alter:

Description

compile phase1dr alter 'if ( seid=0 and mdacms and nooset','' PARAML USET0//'USET'//////'c'/S,N,NOcSET/ 'r'/S,N,NOrSET $ if ( seid=0 and mdacms and nooset>-1 and nocset-1 ) then $ alter 'merge lammats' else $ equivx mis/mi/-1 $ equivx lammats/lammat/-1 $ endif $ compile semr3 alter 'splitfs=','' splitfs=(seid=0 and novgfs>0 and not(fluid)) $ alter 'trnsp.*vvfs'(,-1) if ( methfl>0 ) then $ alter 'call cmpmode'

Known Error

CR 1-54353683 endif $ alter 's,n,nmf','' paraml cmphof//'trai'/1/s,n,nmf//s,n,nocmphof $ if ( nocmphof>-1 ) then $ alter 'diagonal cmmif'(,-1),'' if ( splitfs and nocmphof>-1 ) then $ alter 'merge.*cmphof' else $ merge , ,goq,,, ,vofx/goqq/1 $ endif $ alter 's,n,nmf'(2,-1),''(2,0) if ( splitfs and nocmphof>-1 ) then $ alter 'call newlamax' else if ( splitfs ) then $ merge , ,,,cmpho, ,vofx/cmphoxx/1 $ equivx cmphoxx/cmpho/-1 $ merge , ,,,cmpha, ,vafx/cmphaxx/1 $ equivx cmphaxx/cmpha/-1 $ endalter

Known Error

CR 1-54367171

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Elements - UWM 7651 for QUADR elment may be incorrectly issued

Description

The UWM 7651 for QUADR is issued to warn user that a QUADR element may have very small angle between two sides of the element so that a gird point normal vector is unable to be defined. However, this message may be incorrectly issued for very small retangular elements (1.0-4 on each side).

Known Error

CR 1-54371211

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Linear Contact - BCONTACT, RBE, MPC - Access Violation

Description

A linear contact model in SOL 101 that contains RBE elements or MPC equations will fail with an access violation.

Known Error

CR 1-54381101

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

External Superelements - CSET - SFM 6143 (UPARTPR)

Known Error

CR 1-54381101 An external superelement analysis with C-Set specified wll fail with the message: *** SYSTEM FATAL MESSAGE 6143 (UPARTPR) THE SIZES OF THE INPUT MATRICES AND THE DOF SETS ARE INCOMPATIBLE. SPECIFICALLY: The number of rows in KSVV is not equal to the size of the V-set The number of columns in KSVV is not equal to the size of the V-set User Information: Size of input matrix and DOF sets: KSVV : Rows= 4408578 by Cols= 4408578 Set sizes: Major (V-set)= 4443956 Set0 (O-set)= 4443394 Set1 (COMP-set)= 562 Avoidance: Insert the following DMAP alter $ alter avoidance for CR 1-54381101

Description

compile mhred alter 'merge.*gots,,,gotf' partn kvv,vvfx,/koo,,, $ partn mvv,vvfx,/moo,,, $ call modmodes uset,phio,phic,kv,moo,koo,gots,mv,vvfx,vtfx/ goq,mqq,kqq/norc/1/true/false $ alter 'endif \$ novvfs'(4),'' alter 'call modmodes','' call modmodes uset,phio,phic,kv,moo,koo,got,mv,,/ goq,mqq,kqq/norc/1/true/false $ endif $ novvfs>0 compile semr3 alter 'merge.*kqqf,,,kqq,vfs'(,-1) if ( norc>-1 ) then $ partn kqq,vfs,/kqqf0,,,kqqs $ merge kqqf,,,kqqs,vfs,/kqqw $ matprn kqqf0,kqqf/ $ else $ alter 'merge.*kqqf,,,kqq,vfs' endif $ compile modmodes alter 1,1 SUBDMAP MODMODES USET, CMPHO, CMPHRC, LAMMAT, MOO, KOO, GOT, MI, vvfx,vtfx/ CMPHOX, MIX, KIX/ NORC/NOMVJJS/DOTRIP/uim5490 $

Known Error

CR 1-54381101 alter 'umerge.*uset'(,-1) dbstatus vvfx//s,n,novvfx $ if ( novvfx>0 ) then $ merge cmpho,cmphrc,,,,vvfx/cmphv/1 $ NORM CMPHV/CMPHVN $ delete /cmphv,,,, $ partn cmphvn,,vvfx/cmphon,cmphrcn,,/1 $ delete /cmphvn,,,, $ partn got,vtfx,/,,gorc,/1 $ else $ alter 'UPARTN.*USET,GOT' endif $

Known Error

CR 1-54407131

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SOL 600 - Material orientation causes convergence problems in SOL600

Description

Specifying a material orientation angle by referening a coordinate system may cause convergence problems in SOL 600.

Known Error

CR 1-54412161

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Large Models - SEQP - Integer overflow in matrix reordering routines

Description

Large models that request more than 4gb of memory may fail with an integer overflow in the metis or bend ordering routines.

Known Error

CR 1-54508861

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Dynamic Analysis - HYBDAMP entry - Wrong answers

Description

When hybrid damping (i.e., modal damping is converted to physical damping) is requested in a direct dynamic solution sequence with the HYBDAMP Bulk Data then the internally calcuated eigenvalues may not be the same as those obtained in an equivalent SOL 103 run. Then the subsequent damping values looked-up in the referenced TABDMP1 entry will be wrong. Avoidance: Insert the following DMAP alter ECHOOFF $ COMPILE HYBDAMP NOLIST $

Known Error

CR 1-54508861 ALTER 35,35 $ ENDALTER $ ECHOON $

Known Error

CR 1-54538461

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

External Superelements - PARAM,FIXEDB,-1 but no output request fails with SFM 3001 in MODACC

Description

A SOL 103 external superelement run with PARAM,FIXEDB,-1 but no output request fails with SFM 3001 in the MODACC module in the SEDISP sudDMAP.

Known Error

CR 1-54580661

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

External Superelements - A large external SE job fails with SFM 4276 in the INDXBULK module

Description

A large external SE job fails with SYSTEM FATAL MESSAGE 4276, Error Code 3002 in the INDXBULK module due to an integer overflow in the SAVPS3 c all.

Known Error

CR 1-54644041

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SOL 600 - Access Violation in trgp1cx.F

Description

A large SOL 600 resulted in a memory overflow in trgp1cx.F resulting in a fatal message indicating an access violation.

Known Error

CR 1-54647811

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL 400 - BCONTACT - SIM 8100 (NL3INT), SFM 4276 (PACKI) or UFM 2010 (MCNTCOL) SOL 400 contact problems may fail on some machines with the message:

Description

*** SYSTEM INFORMATION MESSAGE 8100 (NL3INT) No Lagrange Multiplier Degrees-of-freedom were found in Contact analysis.. % 0.4000 4 1 3.08E-01 2.49E-03 2.77E-02 1.000 0 1 0 5.73E-02 9.124E+01 6.46E-03 -5.296E-01 18536 2 1.00 0 5 0 9 analysis ends because of 2 errors in stress recovery

Known Error

CR 1-54647811 *** FATAL NON-LINEAR ELEMENT ERROR or SYSTEM 4276 (PACKI) or USER FATAL MESSAGE 2010 (MCNTCOL) Avoidance: For contact problems the PFNT rather than the AUTO method is recommended. If the AUTO method is selected then switch to PFNT. If the problem is being run on an i8 system, running on i4 may allow the problem to complete.

Known Error

CR 1-54657775

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SOL 600 - Incorrect Thermal Load Translation

Description

When converting thermal loads, SOL 600 may create distributed flux entries that reference tables that do not exist. This may lead to wrong answers.

Known Error

CR 1-54740198

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Design Optimization - External Superelement and MODTRAK - System Fatal Message 6551 (INPTX2) If an external superelement is assembled into a SOL 200 run which also requests mode tracking with MODTRAK and data recovery is requested for the external superelement then the run may fail with SFM 6551 in the INPUTT2 module. This error has been fixed in MD R2.1 when scr=yes; however, when scr=no the same error occurs.

Description Avoidance: Insert the following DMAP alter: compile super3 alter 'IF ( DLOOP'(2,0),'IF ( DLOOP'(2,0) $ CALL EXTIN ,,,,,,XSOP2DIR,EXTDB,,,/ ,,,,,,,,/ SEID/SETYPE/LUSETS/FALSE/S,NP $ Known Error

CR 1-54766131

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Issue fatal error for SLAVE/MASTER ID's that do not have a corresponding BCBODY ID

Description

For SOL 101 and 400, if a SLAVE or MASTER ID that does not have a matching

Known Error

CR 1-54766131 BCBODY a warning is issued, but it should be fatal

Known Error

CR 1-54884981

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SOL 600 - Fails when running from a location that has spaces in its path.

Description

SOL 600 fails when running from a location that has spaces in its path which is allowed and common on Windows systems.

Known Error

CR 1-55020351

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Elements - PBRSECT/PBMSECT with CP/OP - incorrect propeties when segments are nearly parallel PBRSECT/PBMSECT with CP/OP may produce incorrect properties when segments are nearly parallel and having different thickness. In addition, the properties could be wrong if the length of segment is shorter than the thickness of the segment.

Description

Avoidance: merge two nearly parallel segments into one if possible Analysis: 1. nearly parallem problem will be solved with new logic which is more robust 2. a fatal message will be issued for segments with length shorter than thickness 3. additional logic will be implemented to make sure first loop is indeed the outmost of the cross section

Known Error

CR 1-55046437

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Connection Elements - CFAST - UFM 2007, Incorrect element identified The MODGM2 module does not identify the correct poorly specified CFAST element id when the module issues a UFM 2007,

Description

*** USER FATAL MESSAGE 2007 (EPTBED) CFAST ELEMENT 110015 ORIENTATION VECTOR YIELDS BAD PROJECTION Avoidance: If the CFAST definition has the GS field and GA/GB fields specified, as needed for Patran, then try running with only GS specified and the GA/GB fields blank.

Known Error

CR 1-55077699

Product

MSC / MD Nastran

Corrected Version GL Abstract

Elements - TEMPP1, CTRIAX6 - Wrong Answers

Description

TEMPPi entries are not designed to work with CTRIAX6 elements and will produce incorrect results. Avoidance: Define the temperature loading with TEMPD

Known Error

CR 1-55088236

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

Thermal Stress - TEMPP1 cannot be apply to CTRIAX6 - Unexpected Answers, Missing UFM 4016 The CTRIAX6 element does not understand TEMPP1 data. It the data as zero and no warning messages are issued. USER WARNING MESSAGE 4012 followed by USER FATAL MESSAGE 4016 should have been issued. See the documentation on TEMPP1 where CTRIAX6 is NOT on the types.

Known Error

CR 1-55090064

Product

MSC / MD Nastran

Corrected Version 2007.0.2 Abstract

Description

SOL 600 - SOL 600, 153, BCONTACT - Missing jid.ink contact interface file The contact interface file (jid.ink) that is created in a SOL 600, 153 analysis is missing on big endian machines. This causes the nastran analysis to fail with the message: " ** Error in SOL 600 thermal contact iname=blank".

Avoidance: Other than running the analysis in a previous release or on a little endian machine, there is no avoidance. Known Error

CR 1-55104451

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SOL 400 - Lmfact is incorrect if the first increment is linear.

Description

The Lagrange multiplier factor LMFACT and PENFN is computed in NLSOLV for SOL 400 module by default. These values are not correctly computed if the

Known Error

CR 1-55104451 first increment is linear (converged imediately)

Known Error

CR 1-55106821

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Aeroelastic Analysis - Misleading error message, UFM 7019 in DSFLTF If the user attempts to constrain a flutter root that has both real and imaginary parts as zero, the following message is produced:

Description

*** USER FATAL MESSAGE 7019 (DSFLTF) RETAINED FLUTTER EIGENVALUE NO. 0 HAS A VALUE OF (0.0,0.0) USER INFORMATION: IT IS IMPOSSIBLE TO DETERMINE THE SENSITIVITY OF A ZERO EIGENVALUE USER ACTION: DETERMINE THE CAUSE OF THIS ZERO EIGENVALUE AND EITHER REMOVE THE CAUSE OR DO NOT SPECIFY THIS ROOT ON A DRESP1 ENTRY. this message has two flaws: a. the count on the retained flutter eigenvalue is low by 1 b. the message repeats for each design variable so that if there are 100 desgn varibles the same message is printed 100 times. User Avoidance: there is no avoidance and basic message is correct but somewhat misleading and should not be repeated.

Known Error

CR 1-55183371

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL400 job with CBUSH or CFAST elements may result in SYSTEM FATAL MESSAGE 5231 (NLARED).

Description

A strain output request in a MDr3 SOL400 job with CBUSH or CFAST elements may result in SYSTEM FATAL MESSAGE 5231 (NLARED). *** SYSTEM FATAL MESSAGE 5231 (NLARED) INCONSISTENT LENGTH ON NONLINEAR APPENDAGE DETECTED FOR ELEMENT 0 *** SYSTEM FATAL MESSAGE 3007 (SDR2) ILLEGAL INPUT TO SUBROUTINE NLARED 0FATAL ERROR

Known Error

CR 1-55217661

Product

MSC / MD Nastran

Known Error

CR 1-55217661

Corrected Version 2010.1.0 (MD R4) Abstract

Description

Optimization/Design Sensitivity - SSG2 - ATTEMPTING TO OUPUT DATABLOCK WHICH ALREADY EXISTS DMAP MODULE SSG2 IS ATTEMPTING TO OUTPUT DATABLOCK 204 NAME = FPA , WHICH ALREADY The above error message appeared in a SOL 200 run with three subcases with multiple boundary conditions, some of which had design response and others did not. A SOL 200 analysis with multiple subcases and multiple boundary conditions, some of which have design responses and others that do not may fail with the message; DMAP MODULE SSG2 IS ATTEMPTING TO OUTPUT DATABLOCK 204 NAME = FPA , WHICH ALREADY EXISTS Avoidance: The dmap changes required to remedy the problems would be extensive. The best option would be to contact MSC when it appears that a job of the type described above is failing in an way that cannot be diagnosed.

Known Error

CR 1-55221261

Product

MSC / MD Nastran

Corrected Version 2007.0.1 Abstract

Description

Miscellaneou - Missing Timing Constants leads to UWM 6080 (TMALOC) IA64 mode=i8 - Montecito Users may encounter "USER WARNING MESSAGE 6080 (TMALOC)" on Montecito systems running ILP64 (i9). Avoidance: Create Timing constants as descriped in the IOG.

Known Error

CR 1-55221287

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SMP - Tjoin error - IA64 ILP64 Montecito chips Fixed in rnd 33 with INTEGER used instead of "int" in the parallel.c routines.

Description MD Nastran may abort on an SMP parallel runs on Montecito chips running ILP64 mode=8. with:

Known Error

CR 1-55221287 FATAL ERROR: thread: 3664992 routine: tjoin reason: tid_index_lookup error: -999

Avoidance: No know avoidance at this time. Known Error

CR 1-55226901

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Description

SOL 400 - Nonlinear Materials - SFM 6352 (TA1NLM2), LOGIC error 9301 The following error message occurs with a big model using a large buffize of 655537. *** SYSTEM FATAL MESSAGE 6352 (TA1NLM2) LOGIC ERROR: 9301 USER ACTION: CONTACT MSC.SOFTWARE CLIENT SUPPORT. PROGRAMMER INFORMATION: NastType= 33, EID= 100, PID= 60 Avoidance: To avoid the fatal, run with smaller BUFFSIZE, for example, BUFFSIZE=32897

Known Error

CR 1-55227367

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Optimization/Design Sensitivity - Fully stressed design - UWM 7531 For an optimization model, if the model does not contain PROD, PSHEAR, PSHELL, or PCOMP or if the model contains one of the aforementioned entries, but a property is not defined for a fully stressed design, the following warning message (UWM 7531)

Description

NO DESIGNED PROPERTIES IN FULLY STRESSED DESIGN will be issued. Avoidance: If you are not using Fully stressed design, the above warning message can be ignored. If you are using fully stressed design, check your model to make sure that designed properties are deifned for fully stressed design

Known Error

CR 1-55310851

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Documentation/QRG - PARAM,MARVFCUT - Incorrect Default Value

Description

In QRG of 2007r1 and MD r2, the description "Default is 0.001" of PARAM,MARVFCUT is incorrect. The default is 0.0001.

Known Error

CR 1-55343290

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Description

Documentation/QRG - GROUNDCHECK Description of RTHRESH The QRG description of the value of the describer RTHRESH incorrectly states that the default value is 10%. This value needs to be change to a fraction, e.g., the 10% must be changed to 0.10. Otherwise the grounding forces will NOT be output. In fact, if RTHRESH is greater than 1.0, no grounding forces are output. Avoidance: Always have the RTHRESH value less the 1.0 and DATAREC=YES will generate output.

Known Error

CR 1-55358201

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SOL 400 - RBE2, RBAR, and RJOINT give divergent results if cylindrical coordinate system is used.

Description

In SOL 400, the solution will diverge if a cylindrical coordinate system is used for RBE1, RBE2, RBAR, and RJOINT elements.

Known Error

CR 1-55378981

Product

MSC / MD Nastran

Corrected Version 2007.0.2 Abstract

SOL 600 - Translation error for MAXITER parameter of NLSTRAT with multiple SUBCASEs

Description

When multiple SUBCASEs are defined in the case control section, the maximum number of iterations that is defined in the MAXITER parameter of the NLSTRAT is not translated correctly.

Known Error

CR 1-55412111

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SOL 400 - SFM 4276 (UNPACK), EC 31 aix i8 only SOL 400 jobs may fail on aix i8 systems with the message

Description

*** SYSTEM FATAL MESSAGE 4276 (UNPACK) ERROR CODE 31 PID= 0 *** USER INFORMATION MESSAGE 4276 (UNPACK) BIOMSG: ERROR 31 HAS OCCURRED IN ROUTINE UNPACK , FILE INDEX = 0. STATUS = 0 Avoidance: Run on the default i4 system.

Known Error

CR 1-55442675

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SOL 400 - SFM 4549 (NBEM2S) on aix i8 systems in job nlstl01b in redseai8 system. SOL 400 jobs may fail on aix i8 systems with the message:

Description

*** SYSTEM FATAL MESSAGE 4549 (NBEM2S) SINGULAR (C+KBRR) MATRIX ENCOUNTERED FOR BEAM ELEMENT 4 Avoidance: Run on the default i4 system.

Known Error

CR 1-55443121

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SOL 700 - Incorrect error message indicating duplicate TABLED id SOL 700 may incorrectly output the following error message:

Description

*** ErrorMD Nastran Input 103103 TABLED1 2 repeated load curve id ( 2) Avoidance: The error may be avoided by renumbering TABLES entry.

Known Error

CR 1-55502466

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SOL 400 - ANALYSIS=NLTRAN, RIGID - Incorrect Default for RIGID command

Known Error

CR 1-55502466

Description

In SOL 400, the default for the RIGID case control command should be RIGID=LAGR not LINEAR when ANALYSIS=NLTRAN. Avoidance: Explicitly set RIGID=LAGR

Known Error

CR 1-55547101

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Description

CBEAM3 referencing non-composite PBMSECT may produce incorrect result If non-composite PBMSECT(without CORE or LAYER keyword(s) in the definition) is referenced by CBEAM3, sectional properties produced are based on assumed material properties. The assumed material properties are E=3.+6 and mu=0.3. The results from CBEAM3 could be different significantly from the results from CBEAM. Avoidance: reference isotropic PBMSECT only by CBEAM.

Known Error

CR 1-55673351

Product

MSC / MD Nastran

Corrected Version GL Abstract

NLRGAP (and NONINi) with Nastran SPCD relative enforced motion method gives wrong answers.

Description

When using SPCD enforced motion, the integration used the relative displacements (by default). This is incompatible with NOLINs (including NLRGAP) which must use absolute motion. Use PARAM,ENFMETH,ABS to fix this problem. The default has been changed to ABS for Version 2010).

Known Error

CR 1-55735063

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Description

ADAMSMNF - PARAM,AUTOQSET, SPCFORCES - SFM 5423 (MPYAD1) If PARAM,AUTOQSET,YES is requested with ADAMSMNF command and SPCForces are requested then the run will fail with UFM 5423 in the MPYAD module. Avoidance: Insert the following DMAP alter:

Known Error

CR 1-55735063 compile phase1b alter 'ksf1'(2) delete /kfs,,,, $ trnsp ksf/kfs $

Known Error

CR 1-55799501

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SOL 400 - OUTPUT(POST), SDR2 - UFM 2025

Description

There is an error in SDR2 that affects SOL 400 jobs such that UFM 2025 will be issued if there are kinematic elements and the OUTPUT(POST) Case Control command is present.

Known Error

CR 1-55830681

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Description

Aeroelastic Analysis - UFM 315 FORMAT ERROR ON BULK DATA ENTRY UXVEC If the continuation of a UXVEC bulk data entry ends in field 9, the code assumes there is more data for the entry and the next parent entry is processed as a continuation. This will lead to USER FATAL MESSAGE 315, FORMAT ERROR ON BULK DATA ENTRY UXVEC. User Avoidance: A suggested avoidance is to add an additional LABEL and value on an additional continuation vector with the value at 0.0.

Known Error

CR 1-55839394

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Miscellaneousl - DMIG - UFM 4508 (MTRXIN) - a grid and component has been specified twice

Description

If a DMIG entry defines the same component twice it will lead to USER FATAL MESSAGE 4508. However, this message may not correctly identify the duplicate components.

Known CR 1-55876341 Error

Known CR 1-55876341 Error Produc MSC / MD Nastran t Correct ed 2008.0.0 (MD R3) Version Abstrac SOL400 - CQUADX, PSDNL1 - Incorrect Stress Results t Please see following message from Shiva. Changhong ----------------------HI Sanjay, Changhong Descrip This bug was initially assigned to me - I fixed it in cls 42966, 42974, tion 42983 and 42984. It should be working fine now. I thought I had closed it in Siebel. Thanks. Shiva ======================================================================= ==================================== In SOL 400, the STRESS result of the nonlinear axisymmetric element CQUADX that references property entry PSDNL1 is incorrect. Known Error

CR 1-55892751

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

SOL 400 - SPC - Analysis may fail when there is enforced motion in the upstream superelement When there is enforce motion in the upstream superelement(s), SOL 400 job may fail in the Phase 3 - data recovery.

Description

Avoidance: There is no avoidance when there is non-zero enforced motion. However, if Ys is null on the SPC entry, the error may be avoided by substituting the SPC1 entry for the SPC entry.

Known Error

CR 1-55897608

Product

MSC / MD Nastran

Known Error

CR 1-55897608

Corrected Version 2007.1.0 Abstract

SOL 400 - NLIC - UFM 4533 (NLICLP) In a nonlinear transient subcase the user want to reference a step from a previous subcase (NLSTAT). If he use the first step as NLIC all works fine. But if he uses the second step as NLIC two FATAL occure. (No initial conditions found.)

Description

If a SOL 400 nonlinear transient analysis references any step other than the first step as an initial condition, NLIC, the analysis will fail with the message: *** USER FATAL MESSAGE 4533 (NLICLP) THE SPECIFIED INITIAL CONDITION CANNOT BE FOUND IN SUBCASE 1141 STEP 1. *** SYSTEM FATAL MESSAGE 3007 (NLICLOOP) ILLEGAL INPUT TO SUBROUTINE NLICLP 0FATAL ERROR

Known Error

CR 1-55913381

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SOL 400 - QUADR, PLOAD4 - Follower force stiffness symmetrical factor is wrong

Description

In SOL 400, the computation of symmetrical factor for follower stiffness matrix is wrong for the QUADR element. This leads to an unsymmetrical decomp rather than a symmetrical decomp. Thus, the solution iis very inefficient for QUADR with PLOAD4.

Known Error

CR 1-55934951

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Rotordynamics - UNBALNC for Frequence response - SFM 3001 If an UNBALNC entry is used where MASS is set to a real value and therefore there are no TABLEDij entries in the Bulk Data section then the job will terminate with

Description

*** SYSTEM FATAL MESSAGE 3001 (FRLG) THE INPUT DATA BLOCK NAMED DITS AT POSITION 7 DOES NOT EXIST. Avoidance: Insert a dummy TABLEDij entry.

Known Error

CR 1-55974341

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Case Control - GROUNDCHECK - Format error does not lead to UFM This form of the GROUNDCHECK command:

Description

GROUNDCHECK(SET=ALL,DATAREC=ALL,RTHRESH=0.9)=YES should trigger a UFM as DATAREC should not recognize "ALL" as only options YES or NO exist.

Known Error

CR 1-55986678

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

SOL 400 - May fail on ilp64 (mode=i8) systems in the TA1M Module

Description

SOL 400 may fail on ilp64 systems (mode=i8) in the TA1M Module with the followng fatal error. *** FATAL NON-LINEAR ELEMENT ERROR Avoidance: There is no avoidance other than running the default i4 system.

Known Error

CR 1-55992511

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Documentation/QRG - Error in Table of Contents (affects SOL700, SPARSESOLVER and TIME entries)

Description

There is an error in the Table of Contents (Bookmarks tab) of the MD Nastran R2 Quick Reference Guide. This pertains to the PDF file, not the printed book. Under the Executive Control Statement Descriptions, the SOL700, SPARSESOLVER and TIME entries are incorrectly buried under "Restrictions and Limitations of MD Nastran Implicit Nonlinear".

Known Error

CR 1-56030282

Product

MSC / MD Nastran

Corrected Version GL Abstract Description

Heat Transfer Analysis - TEMPBC - DBCMSG 41 The following error message may appear when TEMPBC entries are specified: *** SYSTEM WARNING MESSAGE 6065 (DBC)

Known Error

CR 1-56030282 *** DBCMSG ERROR MESSAGE 41 FROM SUBROUTINE DBCEQE ELEMENT 1000001 WAS PREVIOUSLY ELAS2 AND IS CURRENTLY A HEXA THE DBC MODULES ASSUMPTIONS ARE UNIQUE ELEMENT IDENTIFICATIONS WITHIN A SUPERELEMENT OR RESIDUAL STRUCTURE. This error is caused by the internal generation of CELAS2 entries with element ids of existing elements.

Known Error

CR 1-56095478

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Optimization/Design Sensitivity - BUCKLING - Missing Follower Force leads to wrong answers. When an optimization job perform linear buckling response optimization, the follower force is not included due to a missing table. The eigenvalues do not match with that produced in a SOL105 run. Avoidance: Use the following alter:

Description

compile fea alter 'l sekdr','' CALL SEKDR, SLIST,EMAP,PVT,CASES,CASEM,USET,GPECT,EST, CSTMS,MPTS,DITS,UG,ETT,EDTS,BGPDTS,SILS,MAPS, EQEXINS,GM,GOT,GPSNTS,slt,,SCSTM,MJJ,DEQATN, DEQIND,,, , ,,,,, ,,,,, ,,,,, ,,,,, , , ,THETAM / KDAA,KDMG,KDSF,KDJJ,KDGG,KDSS, / RSONLY/ERROR/LUSETS/COLNO/'BKL0 '/FALSE/FOLLOWK/ 'ALL ' $

Known Error

CR 1-56095773

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

SOL 400 - CQUADX, PLPLANE - UFM 6348, Wrong Answers

Description

A SOL 400 job with CQUADX elements that reference a PLPLANE entry that reference MAT1 rather than the required MATHP material will issue the correct

Known Error

CR 1-56095773 fatal message: *** USER FATAL MESSAGE 6438 (MAT) MATHP ENTRY ID = 1 CAN NOT BE FOUND FOR FINITE DEFORMATION (HYPERELASTIC) ELEMENT ID = 1. but the job will continue and produce incorrect results. -----------------------Fixed MDR4 V2009.0.0

Known Error

CR 1-56123220

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SOL 400 - RBE1 - SFM 6935 (EMGPOM)

Description

SOL 400 with an RBE1 that ran in SOL 106 may fail with a message of the form: *** SYSTEM FATAL MESSAGE 6935 (EMGPOM) ELEMENT-ID = 5390411 FILE TYPE = 1 15 14 196 60 INCONSISTENT NUMBER OF COLUMNS OR TERMS SENT BY ELEMENT ROUTINE FOR PACKING OUT BY EMGPOM, OR INVALID INFORM-OUFORM COMBINATION.

Known Error

CR 1-56149641

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Documentation/QRG - SPARSESOLVER Executive Command Not Documented The MSC.Nastran 2007 SPARSESOLVER Executive Statement is not documented in the MSC.Nastran 2007r1 Quick Reference Guide.

Description

Avoidance: Use the MD Nastran R2 Nastran Quick Reference Guide for information on the SPARSESOLVER Executive Statement. System Cell 206 (DCMPSEQ) also needs to updated to reflect the default change from method 4 to method 8.

Known Error

CR 1-56172081

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SOL 400 - Kinematice elements (RBAR etc.) and superelements results in UFM 5217

Known Error

CR 1-56172081

Description

For SOL 400, if the kinematic elements are used in conjunction with superelements, the job will aborts with USER FATAL MESSAGE 5217 in the GP1 module.

Known Error

CR 1-56172149

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SOL 400 - Missing MPCF output for kinematic elements (RROD)

Description

For SOL 400, under certain condition, the MPCF output will not be printed in f06 file for a model with RROD elements and 3D contact.

Known Error

CR 1-56172177

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract Description

SOL 400 - CONV=UPW and CONV=PV on NLPARM entry cannot be mixed. For SOL 400, if step 1 specifies CONV=UPW, and step 2 specifies CONV=VP on NLPARM entry, the CONV used for both step 1 and step 2 is CONV=VP. Avoidance: There is no avoidance.

Known Error

CR 1-56189563

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Rigid Elements - TEMP(LOAD), SSG1 - UFM 4297 (TQD4D) Incorrectly issued For a model with many RBE2s and/or RBE3s that use the Lagrange rigid elements with thermal load, the following misleading error message may be issued. The problem is due to the BGPDT table being corrupted. *** USER FATAL MESSAGE 4297 (TQD4D) QUAD4 ELEMENT WITH ID =xxxxxx HAS AN INTERIOR ANGLE POSSIBLY GREATER THAN OR EQUAL 180 DEGREES.

Description In this case, the element that is referenced by the fatal message does not have an interior angle anywhere close to 180 degree. Avoidance: There are 2 partial avoidances: 1. The job will run with mechanical loads. 2. The job will run with thermal loads provided alpha is not used on the rtype elements Known Error

CR 1-56191541

Known Error

CR 1-56191541

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Cyclic Symmetry - Memory errors with SOL 115 (Cyclic Normal Modes) Memory error with a SOL 115 (Cyclic Normal Modes) simulation when using MSC.Nastran 2007; the same model runs okay using MSC.Nastran 2005r3. The MSC.Nastran 2007 Release Guide indicates changes were made to "Improved Selection of Reordering Methods". The Release Guide also indicates "If the default method fails, the program will attempt to use another hybrid method (for example, if BEND fails, the program tries METIS).", however in this case it appears the default case is failing but another method is not being attempted.

Description

For the test model attached the following FATAL message occurs using MSC.Nastran 2007. *** SYSTEM INFORMATION MESSAGE 6916 (MREORDR) DECOMP ORDERING METHOD CHOSEN: DEFAULT, ORDERING METHOD USED: METIS *** SYSTEM FATAL MESSAGE 7796 (DFMSA) THE MAXIMUM INTEGER VALUE IS EXCEEDED. USER INFORMATION: THE MAXIMUM INTEGER NUMBER ALLOWED ON YOUR MACHINE IS 1073741823. HOWEVER, THE NUMBER OF REAL STACK ELEMENTS WAS COMPUTED TO BE 1193790349. USER ACTION: USE A DIFFERENT RE-ORDERING SCHEME VIA SYSTEM(206), OR REDUCE THE SIZE OF YOUR MODEL. *** USER FATAL MESSAGE 6136 (DFMN) INSUFFICIENT CORE FOR NUMERIC PHASE OF SPARSE DECOMPOSITION. USER ACTION: INCREASE CORE BY AN ESTIMATED 307941 K WORDS. WARNING: THE ABOVE NUMBER IS ONLY AN ESTIMATE, THE ACTUAL CORE SIZE NEEDED MAY BE HIGHER. 0FATAL ERROR

Avoidance: Apparently the changes for the MSC.Nastran 2007 default ordering method for sparse matrix decomposition requires significantly more memory for this application. To avoide the error change the default sparse matrix decomposition method using a Nastran system cell [NASTRAN SYSTEM(216)]. SYSTEM(206)=4

Known Error

CR 1-56191541 a. On the command line: C:\MSC.Software\MSC_Nastran\bin\nast2007 jid=test_dyn.dat scratch=no SYSTEM(206)=4 b. By adding the following line to the top of the MSC.Nastran input file: NASTRAN SYSTEM(206)=4

Known Error

CR 1-56461590

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Fix error related to extrapolation of stresses for material nonlinear TETRA elements

Description

The error is related to extrapolation of stresses for material nonlinear TETRA elements. The method of extrapolation has been corrected in 2010 and is consistent with that for HEXA and PENTA elements.

Known Error

CR 1-56470203

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Description

Optimization/Design Sensitivity - PBAR/PBARL - Incorrect Punch File When both PBARL and BAR are designed in an optimization job and ECHO=PUNCH(NEWBULK) is specified, the PBAR values may be the original property values. Furthermore, internally generated PBAR entries that should be written to the punch file as a comment, may be missing the preceding "$". Avoidance: Manually update the PBAR entries and comment out the internally generated PBAR entries.

Known Error

CR 1-56475731

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Documentation/IOG - FLEXlm - License Servers separated by colon on windows not allowed

Description

The IOG on page 39 fails to document that unix and windows require different separators between the specification of multiple license servers. Windows requires the use of a semicolon while unix requires a colon. No error message

Known Error

CR 1-56475731 will be displayed on windows unless pause=yes is sepcified.

Known Error

CR 1-56478211

Product

MSC / MD Nastran

Corrected Version Abstract

SOL 153 - No Volumetric Heat Generation (QVOL) load output with material Heat Generation Multiplier SOL 153 - No Volumetric Heat Generation (QVOL) load output with material Heat Generation Multiplier using MATT4

Description

Th eoutput for the actual power into the grid is missing in the F06 file Avoiance: look at the reaction force for the total power input Note: this error also occurs in SOL 400

Known Error

CR 1-56537391

Product

MSC / MD Nastran

Corrected Version GL Abstract

Default setting of radiation enclosure calculations may add heat to system.

Description

Due to inaccuracies, the default setting of view factor calculation in an opened enclosure may result in energy loss (sum of view factors < 1.0) or energy gain (sum of view factors > 1.0) in the system. In most conditions, the radiation will be lost to space because the sum of view factors is less than 1.0; however, there exists some cases that the heat is added to the system because the sum of view factors is greater than 1.0. To achieve accurate results, the user may specify NASTRAN SYSTEM(87)=3 to scale back the sum of view factor to 1.0 so that all radiation energy will be conserved.

Known Error

CR 1-56544651

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Description

DMAP - MAT3 contains incorrect description in the NDDL - Inefficient restarts, Incorrect table print The MAT3 record in the MPT table description in the NDDL is incorrect. This may result in inefficient restarts if MAT3 entries are used and an incorrect neutral or non-native file transfers involving the MPT data block. Avoidance: There is no avoidance.

Known Error

CR 1-56597055

Known Error

CR 1-56597055

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Exterior Acoustic - DOMAINSOLVER ACMS, SPCD - UFM 6144 (PARTN1PR)

Description

An exterior acoustic analysis that uses ACMS and applies enforced displacements via SPC may fail with USER FATAL MESSAGE 6144 (PARTN1PR).

Known Error

CR 1-56614331

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Description

SOL600 - DMIGOUT, KIND=1 - Does not work DMIGOUT with KIND=1 specified is to output dmig matrices for those elements specified; however, no elements will be output. Avoidance: The only avoidance is to output all elements by using the default KIND=2.

Known Error

CR 1-56627786

Product

MSC / MD Nastran

Corrected Version Abstract

SOL 400 - PARAM,LGDISP, BCONTACT - Failued to Converge or Incorrect Result

Description

In SOL 400 3D contact analysis with large displacement, the job may fail to converge or produce wrong results when there is a large rotation increment with no contact occuring, followed by a subase with contact.

Known Error

CR 1-56636361

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Description

Optimization/Design Sensitivity - DRESP1, FRFORC, ATTB=MAX - Incorrect Response, Failure DOPR3 SOL 200 jobs with FRFORC specified for RTYPE and MAX specified in the ATTB field of the DRESP1 entry may produce incorrect response values if the enhanced DRESP1 is itself slected as a constraint. The analysis may fail in the DOPR3 module if the enhanced DRESP1 is further referenced on a DRESP2 entry. Avoidance: The enhanced DRESP1 must be expanded with one dresp1 for each forcing frequency and, a separate DRESP2 entry with MAX in the EQID field

Known Error

CR 1-56636361 to include all DRESP1 must be used.

Known Error

CR 1-56636931

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Performance - MMD Reordering selected for dense structures results in poor performance.

Description

When METIS reordering is selected, it may failure due to any number of reasons, including insufficient memory or too dense a structure. When METIS fails because of a too-dense structure, MMD is selected, which gives very poor performance. BEND should be selected rather than MMD.

Known Error

CR 1-56637009

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

DMP - PRESOL may hang when a partition failure occurs.

Description

When running DMP, the PRESOL module may hang on the slave nodes if it is unable to partition the model into the required number of domains.

Known Error

CR 1-56679235

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

SOL 700 - "WORKSHOP 1 TAPERED BEAM IMPACT" contains bad contact definition

Description

The SOL 700 WORKSHOP 1 TAPERED BEAM IMPACT model contained an incorrect contact definition and would not run. This has been corrected in MD R3.

Known Error

CR 1-56693451

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

Results from Nastran contact analysis (status) NOT on op2/xdb, but ONLY on dball (dra) results from an MD R2 Nastran contact analysis (e.g. SOL400) are only available on the dball file only and not on op2/xdb The op2 is supported in MD 2010.

Known Error

CR 1-56752917

Known Error

CR 1-56752917

Product

MSC / MD Nastran

Corrected Version Abstract

In random Analysis, incorrect description of psdf results appears in punch file

Description

1. In random analysis, the PSDF output in PUNCH file got a wrong label description. It should be "IDENTIFIED BY FREQUENCY", not by "TIME". 2. This is a code bug. 3. No avoidance available.

Known Error

CR 1-56780151

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Multipoint Constraints - LOAD, MPCD - Missing Documentation

Description

The MD R2 QRG for the LOAD Case Control command was not updated to indicate that it may reference and MPCD bulk data entry. Remark 2 under the documentation for the MPCD bulk data entry indicates that in dynamic analysis the EXCITE ID is selected by the EXCITE ID of the ROAD1, RLOAD2, TLOAD1, or TLOAD2, entries but this capability is not yet functional.

Known Error

CR 1-56870064

Product

MSC / MD Nastran

Corrected Version Abstract

Nonlinear Analysis - Non-convergence for a thermal model(iteration temperatures below 0 absolute) Temperature values allowed to fall below 0 degrees absolute during iterations and non- convergence occurring.

Description

A MSC.Nastran steady state thermal analysis with a cooling load and radiation as the primary method of heat transfer is failing with the fatal message as shown below. *** SYSTEM FATAL MESSAGE 7601 (NCONVG) NUMERIC OVERFLOW ENCOUNTERED DURING THE CALCULATION OF CONVERGENCE PARAMETERS. USER INFORMATION: THIS CONDITION MAY BE CAUSED BY ZERO OR LOW INITIAL TEMPERATURES (SEE TEMP AND TEMPD BULK DATA ENTRIES) FOR RADIATION HEAT TRANSFER ANALYSIS AND MAY BE RESOLVED BY RAISING

Known Error

CR 1-56870064 THE INITIAL TEMPERATURE. The problem is that a high initial guess for temperature causes nonconvergence and for this model (with a variable cooling load & radiation as the primary method of heat transfer) a very close initial guess is necessary for convergence (use TEMPD = 60). During the solution iteration (DIAG, 51) it is found that the “NEW DISPLACEMENT VECTOR― provides temperature below zero degrees absolute which is physically impossible. RECOMMENDATION: 1) For simulations involving radiation or if the TABS value is set do not allow the temperatures to fall below zero degrees absolute during the solution/iteration phase (as this is physically impossible) and issue a warning message indicating the iteration temperatures are being reset to zero degrees absolute (based on the TABS value) for any values below zero degrees absolute. If radiation is not present or the TABS value is not set allow temperatures below zero as users may not be modeling in absolute temperature scale. 2) If radiation is present in a simulation issue a warning message if the TABS value is not set. Indicate that the temperatures are assumed to be in absolute scale (Kelvin or Rankin).

Known Error

CR 1-56880211

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Shape Optimization - BNDGRID and superelements and UFM 9067 - Wrong answers If shape optimization is requested in the presence of superelements then UFM 9067 will be issued but the run is not terminated. This may result in wrong answers. Avoidance: Insert following alter:

Description compile desopt alter 'ENDIF \$ (AMBS'(,-1) call prtsum /rstjunk $ exit $ endalter Known Error

CR 1-56928981

Known Error

CR 1-56928981

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Optimization/Design Sensitivity - RIGID=LAGR - Lanczos with SFM7349 (LNNHERR) Three independent bugs are identified in the report for a SOL200 job with RIDID=LAGR Case Control command; A Lanczos eigenvalue analysis in SOL 200 with RIGID=LAGR may fail with the message: SYSTEM FATAL MESSAGE 7349 (LNNHERR) being issued from the READ module. Several problems exist: 1) The differential stiffness matrix is not created. 2) Tthe Lagrange rigid element approach is not supported in SOL200 when the grid points connecting rigid elements are being designed. A user fatal error message should be issued. Avoidance: Use the following dmap alter to avoid the first problem:

Description

compile fea alter 'call super3'(2),'' CALL SUPER3, CASEcc , ,UL , , , ,,,,, crx , ,qrg , , , ,PCDB ,XYCDB ,POSTCDB ,FORCE , EMAP ,MAPS ,EQEXINS ,PVTS ,CASES , SLT ,ETT ,GOT , ,LOO , crj , ,UOO , ,GPLS , USET ,SILS ,PJ ,EDTs ,YS , GM ,PSS ,KFS ,KSS ,QR , ,,,,, DYNAMICS,BGPDTS ,CSTMS ,MPTS ,DIT , EST ,GEOM2S ,GEOM3S ,ECTS ,EPTS , INDTA ,KELM ,KDICT ,GPECT ,VELEM , ,ditid ,pvtbc ,SCSTM , , ,GEOM4S ,PG , , , ,EPT ,MPT ,GEOM1 ,GEOM2 , GEOM3 ,GEOM4 ,PTELEM , , , CASERS ,errorn ,MEDGE ,VIEWTB , , BGPDTVU ,gpsnts ,pvt ,DEQATN ,DEQIND , GDNTAB ,OINT ,PELSETS ,KSF ,KMG , ,,,,, ,,,,, , , , ,eht , ,,,,, lcdvec , ,matpool , , , ,errorg , , ,pcompts ,

Known Error

CR 1-56928981 ,,,,, , , , ,vgq , xsop2dir,vgdr , ,vspcg ,vmpcg , mmcdb ,geom1qx , , , , ,kaa , , , , kgg , , ,matpools,gei , ,,,,, ym , , ,dmis ,dmindxs , dtis ,dtindxs ,pbrmsd ,pbrms , , ,,/ UG ,QG ,qmg , , , ,,,,, ,,,,, ,,,,, ,/ APP /APP /RSONLY /FALSE /FALSE / FALSE /DROPT /FALSE /S,PFILE /S,CARDNO/ DESCYCL1/FALSE /DMRESD /PEXIST /ADPTINDX/ ADPTEXIT/false /true /0 /false / ' '/dstspcf /rgsens /false /false / false $ alter 'call super3'(3),'' CALL SUPER3, CASEcc , ,UL , , , ,,,,, crx , ,qrg , , , ,PCDB ,XYCDB ,POSTCDB ,FORCE , EMAP ,MAPS ,EQEXINS ,PVTS ,CASadj , SLT ,ETT ,GOT , ,LOO , crj , ,UOO , ,GPLS , USET ,SILS ,PJ ,EDTs ,YS , GM ,PSS ,KFS ,KSS ,QR , ,,,,, DYNAMICS,BGPDTS ,CSTMS ,MPTS ,DIT , EST ,GEOM2S ,GEOM3S ,ECTS ,EPTS , INDTA ,KELM ,KDICT ,GPECT ,VELEM , ,ditid ,pvtbc ,SCSTM , , ,GEOM4S ,PG , , , ,EPT ,MPT ,GEOM1 ,GEOM2 , GEOM3 ,GEOM4 ,PTELEM , , , CASERS ,errorn ,MEDGE ,VIEWTB , , BGPDTVU ,gpsnts ,pvt ,DEQATN ,DEQIND , GDNTAB ,OINT ,PELSETS ,KSF ,KMG , ,,,,, ,,,,, , , , ,eht , ,,,,,

Known Error

CR 1-56928981 lcdvec , ,matpool , , , ,errorg , , ,pcompts , ,,,,, , , , ,vgq , xsop2dir, , , , , mmcdb ,geom1qx , , , , ,kaa , , , , kgg , , ,matpools,gei , ,,,,, ym , , , , , , ,pbrmsd ,pbrms , , ,,/ UG ,QG ,qmg , , , ,,,,, ,,,,, ,,,,, ,/ APP /APP /RSONLY /FALSE /FALSE / FALSE /DROPT /FALSE /S,PFILE /S,CARDNO/ DESCYCL1/FALSE /DMRESD /PEXIST /ADPTINDX/ ADPTEXIT/false /true /0 /false / ' '/dstspcf /rgsens /false /false / false $ endalter

Known Error

CR 1-57011098

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Description

Elements - CSHEAR, MAT1 - EMG Module, Subroutine TRANSD Divide By Zero The CSHEAR element may cause the EMG module to encounter a divide by zero when material properties E and G exceed too large a range and NU is left blank on the MAT1 entry. This problem occurs on all shortword (32 bit) operating systems. A long word (64 bit) operating system allows the job to run. Avoidance: Either specify an acceptable value for NU or reduce the range of the E and G values on MAT1 entries that have large E and G.

Known Error

CR 1-57027307

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SOL 400 - M2PP case control command ignored.

Known Error

CR 1-57027307 In SOL 400, a STEP with ANALYSIS=NLTRAN will not process the M2PP case control.

Description

Avoidance: insert the following alter compile nonlin alter 'IF ( TSTATnew\1 and NOMPP\>-1','' if ( true ) then $

Known Error

CR 1-57050333

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

SOl 400 - ANALYSIS=NLTRAN, floating point exception error In SOL 400 with ANALYSIS=NLTRAN, with RBE2 elements and the RIGID=LAGRAN case control option, the job fails with a floating point exception error. ents.

Description

*** USER INFORMATION MESSAGE 6191 (nl3con) *** UNABLE TO ACHIEVE CONVERGENCE FOR THE CURRENT INCREMENT OR TIME STEP, TRY TO FIND THE BEST SOLUTION *** *** USER INFORMATION MESSAGE 6189 (nl3con) *** REPEAT ITERATION, STOPPING AT LOWEST ERROR *** %1.06250E-02 4 5 0.0313 4 2.54E+00 1.00E+00 1.25E+01 0.80 6 0 2.4E+03 2.020E+05 6.19E-02 -3.054E+00 431 6 0 9 38 *** USER INFORMATION MESSAGE 6189 (nl3con) *** BEST ATTAINABLE SOLUTION HAS BEEN FOUND *** MAIN: The FPU has been reset after floating point exception. MAIN: For reference, A(MAINAL) = 401436, A(/SYSTEM/) = 36C4D20 MAIN: A(/XNSTRN/) = 6C20000 MAIN: "Floating point overflow" (C0000091) exception encountered. MAIN: Exception occurred at address 01B91D42. Although the model was apparently failing to converge a floating point exception error should not be occur and Nastran should exit with a more appropriate message. Avoidance: Manually constrain degrees of freedom 456 on the solid elements when using rigid elements.

Known Error

CR 1-57124547

Known Error

CR 1-57124547

Product

MSC / MD Nastran

Corrected Version Abstract

Static Analysis - 3d surface contact - spcforces do not include contact forces

Description

When using the new 3d surface contact in sol 101 and when the contact area contains constrained grids then the equilibrium might be incorrect. The reason is that the contact forces are not included in the spcforces. Please note that this defect does not show up in sol 400.

Known Error

CR 1-57178664

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Description

Eigenvalue Analysis - RESVEC - SWM 9142 ( RESMODES ) When the following warning message is issued in the f06: > ^^^ > ^^^ SYSTEM WARNING MESSAGE 9142 ( RESMODES) > ^^^ THERE WERE PROBLEMS DURING THE RESIDUAL VECTOR EIGENVALUE EXTRACTION > ^^^ USER INFORMATION: THE RUN WILL CONTINUE WITHOUT RESIDUAL VECTORS > FOR THIS SET OF MODES. > ^^^ USER ACTION: POSSIBLE AVOIDANCES: > ^^^ 1. SET F1 ^^^ residual vectors should not be calculated at all. However in this case eigenvalues were calculated having negative generalized mass and infinite stiffness: 48 48 1.000000E+35 3.162278E+17 5.032921E+16 -1.000000E+00 -1.000000E+35 49 49 1.000000E+35 3.162278E+17 5.032921E+16 -1.000000E+00 -1.000000E+35 Avoidance: Insert the following dmap alter: compile resmodes alter 'neigv1'(3,-1) return $ endalter

Known Error

CR 1-57199497

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SOL 600 - BRKSQL entry causes a UFM 307 (IFPDRV) in other solutions

Known Error

CR 1-57199497 The BRKSQL entry will cause solutions other than SOL 600 to fail with the message: *** USER FATAL MESSAGE 307 (IFPDRV) ILLEGAL NAME FOR BULK DATA ENTRY BRKSQL MDR3 beta (V2008.0.0) issues this message

Description

*** USER FATAL MESSAGE 300 (RCARD) DATA ERROR IN FIELD UNDERLINED. POSSIBLE ERROR IN EXPONENT. . 1 .. 2 .. 3 .. 4 .. 5 .. 6 .. 7 .. 8 .. 9 .. 10 . ++000002C:\MSC_APPS\MDR3B\BIN\MDNASTRANW.EXE +000003 ======== it should be ignored.

Known Error

CR 1-57203529

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

MPCD - MPCD with RSSCON does not work with MPCY, Wrong Answers

Description

MPCD entries combined with RSSCON entries may not work correctly and may lead to wrong answers. The MPCY value of Ym on the MPCY entry was not replaced by that of MPCD entry.

Known Error

CR 1-57215871

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SOL 400 - UFM 9103 (NL3INT) MD R2 Nastran SOL 400 nonlinear static simulation may fail with the following message when there is insufficient memory:

Description

*** USER FATAL MESSAGE 9103 (NL3INT) A LOGIC ERROR was encountered WHILE writing data from 3D Contact Component Database to DBALL *** JOB DOES NOT CONVERGE AT THE CURRENT TIME STEP OR INCREMENT. *** FATAL ERROR ENCOUNTED.

Known Error

CR 1-57215871 *** USER FATAL MESSAGE 1133 (GNXFST) INVALID INPUT FIST NUMBER = 0 Avoidance: This message shows up when code try to write data from 3D Contact Component Databast to Nastran Database but INSUFFICIENT MEMORY exists. The message may also be output "INSUFFICIENT MEMORY AVAILABLE FOR SUBROUTINE NL3INT". Increase memory and rerun.

Known Error

CR 1-57215920

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL 400 - MATORT - UFM 2042 SOL 400 does not support MATORT and if referenced by a PSOLID entry will fail with the message:

Description *** USER FATAL MESSAGE 2042 (M3DCONT1) MISSING MATERIAL TABLE 1 FOR ELEMENT 51585 Known Error

CR 1-57219403

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Acoustic Analysis - PARAM,ASCOUP - UFM 6148 (GP5A1) with FLUID only model. A fluid only model will lead to the following fatal message and including PARAM,ASCOUP,NO as directed will not solve the problem. *** USER FATAL MESSAGE 6148 (GP5A1) NO STRUCTURAL ELEMENTS FOUND IN THE BULK DATA FOR FLUIDSTRUCTURE COUPLING.

Description

USER ACTION: INCLUDE STRUCTURE OR USE PARAM,ASCOUP,NO TO AVOID FLUID-STRUCTURE COUPLING. Avoidance: Apply the following dmap alter: compile phase0 alter 'acoustic=2','' $ if( ascoup='yes' and acoustic=2 ) then $ endalter $

Known Error

CR 1-57219431

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SOL 600 - marc command - error, scratch directory "c:/04_appl/scratc" In SOL 600, nastran may truncate the sratch directory name specified on the marc submittal command and this may lead to the message:

Description

*** ISHELL PROGRAM 'c:\04_appl\nastran\md_r2_ccs\md2007\marc_8664\\tools\run_marc' STARTED *** error, scratch directory "c:/04_appl/scratc" does not exist

Known Error

CR 1-57297901

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SOL 400 - QUADR, TRIAR - Element formulation fails, UFM 7681 (SOPMPD) SOL 400 with QUADR or TRIAR elements may fail with the message:

Description

*** USER FATAL MESSAGE 7681 (SOPMPD) IN PLASTIC ANALYSIS, THE DELTA EFFECTIVE STRAIN ( -1.151181E-07 ) IS NEGATIVE FOR ELEMENT ID = xxxx. THIS MAY BE CAUSED BY UNRESONABLE MATERIAL PROPERTIES.

Known Error

CR 1-57303091

Product

MSC / MD Nastran

Corrected Version Abstract

Description

Matrix Methods - iterative solver does not work with PARAM,INREL,-2 When the iterative solver is used with PARAM,INREL,-2 , which is the automatic suports for inertia relief, the following error is received: " ^^^ USER FATAL MESSAGE 9058 (SUPER3) ^^^ THE SOLUTION FOR THE RESIDUAL STRUCTURE DOES NOT EXIST. " Avoidance: Use PARAM,INREL,-1

Known Error

CR 1-57309391

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Frequency Response Analysis - DLOAD entry referencing null enforced motion - UFM 5423

Known Error

CR 1-57309391 A frequency response job with a DLOAD Bulk Data entry referencing null enforced motion fails with UFM 5423 on a call to MPYAD in the FRLG module.

Description Avoidance: Remove reference to null enforced motion from the DLOAD Bulk Data entry. Known Error

CR 1-57340784

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Description

Nonlinear Analysis - PCOMP, TEMP(LOAD) - SFM 4016 (TA1ETD), UFM 2016 Nonlinear analysis with composites and temperature loads may fail in MSC.Nastran 2007r1 and MD Nastran R2 with SYSTEM FATAL MESSAGE 4016 (TA1ETD) indicating that there are missing temperature entries for some elements or USER FATAL MESSAGE 2016 indicating no material properties exist. Not sure why this CR was assigfned back to me. I came across with other data file (CGAP with thermal load) and Nastran issue SFM 4106 (TA1ETD) - there is not temperature data for cgap elements - even though temp is defined at both end- See bdf file 'thermal-cgap.dat'

Known Error

CR 1-57344451

Product

MSC / MD Nastran

Corrected Version Abstract

Superelements - MPCY/MPCD with non-zero constant coefficient term produce wrong results

Description

Non-homogeneous MPC equations (using MPCY and/or MPC/MPCY/MPCD) produce wrong results when they are used in conjunction with superelements. The problem could be limited to MPC that are connected to the SE boundaries.

Known Error

CR 1-57370845

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract Description

Exterior Acoustic Analysis - INTENSITY Case Control - Wrong results In exterior acoustic analysis, if shell elements are wetted on both sides then INTENSITY output may show incorrect results. Avoidance: None.

Known Error

CR 1-57381186

Product

MSC / MD Nastran

Corrected Version 2010.1.1 Abstract

SOL 153 - Tet4 or Tet10 elements with orthotropic thermal properties cann't be temperature dependant SOL 153 - Tet4 or Tet10 elements with orthotropic thermal properties cann't be temperature dependant With Tet4 or Tet10 elements and orthotropic thermal properties, materials properties cann't be temperature dependant.

Description

If material caracteristics are linear, the solution is correct for all elements. If material caracteristics are temperature dependant, the solution is correct only for Hexa8 elements. Avoidance: 1) use SOL 400 with new nonlinear element formulations such as psldn1, then the Tetra will get the correct solutions 2) use CHEXA8 in SOL 153 will also get the correct results

Known Error

CR 1-57406941

Product

MSC / MD Nastran

Corrected Version 2007.0.2 Abstract

SOL 400 - Moment-carrying Glued Contact failed when contacting grids have coordinate transformation

Description

In SOL 400, moment-carrying glued contact may fail when contacting grids have a coordinate transformation and LGDISP is specified.

Known Error

CR 1-57475308

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

External Superelements - DMIGPCH - data recovery missing

Description

If more than one external superelement is created with DMIGPCH then in the assembly run, the data recovery may be incomplete for one or more of the external superelements. Avoidance: There is no good avoidance other than to not use DMIGPCH or to use it on only one external superelement.

Known Error

CR 1-57683171

Product

MSC / MD Nastran

Known Error

CR 1-57683171

Corrected Version 2007.1.0 Abstract

Nonlinear Analysis - AUTOSPC is deactivated with glued (permament) contact in non-static solutions AUTOSPC is deactivated with glued (permament) contact in non-static solution sequences.

Description

Avoidance: Insert the following DMAP alter: Compile sekr0 Alter ‘nocont’ Nocont=0 $ Endalter

Known Error

CR 1-57697805

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Submittal - Nastran Command Processor does not handle the j.env keyword properly

Description

The Nastran Command Processor does not handle the "j.env" keyword as per its documentation and it does not allow "path" specifications as part of an environment variable value definition. It must be extended to properly handle the "j.env==:=:..." specification and to allow colon/semi-colon separated directories as part of the value strings. The colon/semi-colon in the value string mumst be "escaped" by preceding it with a caret (^) on Windows and a backslasn (\) on Linux/UNIX.

Known Error

CR 1-57703594

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

Optimization/Design Sensitivity - PARAM,INREL,-2 - SFM 5423 (MPYAD1) A SOL 200 optimization analysis using the INREL, -2 inertia relief capability will fail. With SUBCASEs that only invoke inertia relief and INREL,-2 is in the BULK or defined in each SUBCASE the SFM 5423 (MPYAD1) is issued after entering design cycle 1. If all subcases invoke inertia relief with parm,inrel,-2 or the parameter is in the bulk data , the job will fail with SFM 5423 in (MPYAD1) indicating an incompatible matrix multiply. See also related CR 1-73356415. SYSTEM FATAL MESSAGE 5423 (MPYAD1) ATTEMPT TO MULTIPLY INCOMPATIBLE MATRICES FILE# COLS ROWS FORM TYPE NZWD DENS

Known Error

CR 1-57703594 TRAILER FOR PT6 IS 101 1 330 2 2 654 9909 TRAILER FOR QRX IS 102 1 6 2 2 12 10000 Avoidance: Insert the following DMAP alter (also includes avoidance for 1-73356415) compile phase1dr alter 'PVT.*PVTS,'(3),'' compile dstatrs alter 'Paraml.*pl'(2),''(2,4) dbview pl6=pl where (inertia) $ if ( ndvar>1 ) then $ paraml pl6//'trai'/1/s,n,ncol $ matgen ,/spaw1/4/ncol/6/0/1/6/1/1/6 $ diagonal spaw1/spawn/'whole'/0. $ smpyad pl6,spawn,qrx,,,/qra/3/-1////1 $ else $ Mpyad pl6,qrx,/qra//-1 $ sign change endif $

Known Error

CR 1-57715830

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL 400, NLTRAN, Contact -> UFM 1 (MCNTINI) A model with a BCBODY of 2D and 3D will fail in IFPS M3DCONT1 with the following message:

Description

*** USER FATAL MESSAGE 1 (MCNTINI) *** USER FATAL MESSAGE Body (dimension) *** USER FATAL MESSAGE 1 (MCNTINI) *** USER FATAL MESSAGE 65 (2) 0*** SYSTEM FATAL MESSAGE 3062 MODULE = M3DCONT1 A more descriptive error message is now issued in 2010

Known Error

CR 1-57748225

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Enhanced error message is required when the initial contact fails

Description

In MDr3.1 and earlier version of MD Nastran, when the initial velocity is defined but contact cannot be found after 1000 trials in the initial contact.

Known Error

CR 1-57748225 System Fatal Message 3062 is issued without explaining the reason. *** SYSTEM FATAL MESSAGE 4 (MCNTINI) *** SYSTEM FATAL MESSAGE Marc (cnx_distrt) 0*** SYSTEM FATAL MESSAGE 3062 MODULE = M3DCONT1 FAILURE OCCURRED IN UTILITY ^@^@^@^@^@^@ CALLED IN SUBROUTINE MCNTINI . 0FATAL ERROR Avoidance: No avoidance available.

Known Error

CR 1-57808041

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Description

Elements - CFAST element may cause job to fail with Signal=11 job aborting in MODUG In certain cases, CFAST element may cause job to fail with Signal=11 job aborting in MODUG Fix has been imported and verified.

Known Error

CR 1-57898528

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Superelements - SOL 400 and 101 with contact will fail with SFM 2007 when superelements are defined

Description

SOL 400 and 101 with contact will fail in CNTLSTR with SYSTEM FATAL MESSAGE 2007 in CNTLSTR when superelements are defined. The message indicates that an element references an undefined grid point 0.

Known Error

CR 1-58051631

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SOL 400 - RBE1, RBE2, RBE3 with Superlements in SOL 400 leads to UFM 6599

Description

If there are RBE1, RBE2, or RBE3 rigid elements in a model with superelements in SOL 400, the job will fail with USER FATAL MESSAGE 6599.

Known Error

CR 1-58051791

Known Error

CR 1-58051791

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Description

External Superelements/Fluid Response - DMIGPCH - Zero Fluid Response The fluid response of grid points that are interior to the fluid cavity and interior to fluid-structure superelement, are zero in an assembly run using DMIGPCH external superelement. Response on DISP output request in Sol 103 EXTSE creation run produces correct response using DMIGOP2 method. An assembly run also produces correct, distinct structure and fluid eigentables with DMIGPCH, so the VAFSX & AAX DMIG's are being processed, but the fluid modal solution is not calculated. Signif work done since 2007r1 to make DMIGPCH as fully operational as DMIGOP2 and other larger storage options - including this fix for interior fluid SE responses in assy data recovery.

Known Error

CR 1-58071249

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Acoustic analysis - FLSPOUT and XYplot commands - Wrong output for PHASE and IMAGINARY values Although FLSPOUT outputs MAGNITUDE/PHASE and REAL/IMAGINARY values, acoustic XY-plot outputs MAG or REAL values only. Avoidance: Specify the item code as follows: For MAGNITUDE and PHASE ;

Description

FLSPOUT ... : OUTPUT(XYPLOT) XYPUNCH FMPF(5) MODE / 1041(T1RM) $ to get the magnitude part punched XYPUNCH FMPF(5) MODE / 1041(T2) $ to get the phase part punched For REAL and IMAGINARY ; FLSPOUT ... PSORT=(REAL,DESCENDING) : OUTPUT(XYPLOT)

Known Error

CR 1-58071249 XYPUNCH FMPF(5) MODE / 1041(T1RM) $ to get the real part punched XYPUNCH FMPF(5) MODE / 1041(T2) $ to get the imag part punched

Known Error

CR 1-58086386

Product

MSC / MD Nastran

Corrected Version Abstract

Description

Frequency Response - PBUSHT with SPCD - Wrong Answers In a frequency response (SOL 108 or SOL 111) analysis using SPCD enforced motion, if frequency dependent properties are defined on a PDAMPT, PELAST, or PBUSHT entry, the frequency dependence is incorrectly interpolated. Avoidance: None.

Known Error

CR 1-58109626

Product

MSC / MD Nastran

Corrected Version Abstract

Nonlinear Analysis - Missing NLSTRESS for SOLID elements in xdb file A SOL 106 analysis with multiple restarts that selected a NLSTRESS that referenced a SET ID as shown below that contained CHEXA and PENTA elements

Description

NLSTRESS=3 SET 3 =700701 THRU 700717,700801 THRU 700848,700901 THRU 701188, 715973 THRU 716404,716645 THRU 717045,800001 THRU 808008 encountered a message in patran that there were no stress results for the target elements.

Known Error

CR 1-58109847

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SOL 600 - MARF entries Fxy field my be positive for Puck and Hashin criteria

Description

In prior releases Fxy on the MARCF entry was required to be negative. This restriction has been removed in MD R2.1 to allow for Puck and Hashin criteriea.

Known Error

CR 1-58120430

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3)

Known Error

CR 1-58120430

Abstract

DDAM - UFM 740 (RDASGN), DDAM example aborts using UNIT=21 In SOL 187, the default Fortran unit number of 21 for the DDAM input file will cause UFM 740.

Description Avoidance: Reassign unit 21 to 24 in the FMS ASSIGN statement and specify PARAM,IUNIT3,24 in the Bulk Data section. Known Error

CR 1-58361626

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SOL 400 - QUADR with offsets gives wrong answers

Description

A model of QUADR elements with offset gives wrong answers in SOL 400.

Known Error

CR 1-58536061

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Acoustic Analysis - MFLUID, VMOPT,2 - SFM 5423 (MPYAD1), SOL 103 If a model contains both an acoustic cavity (fluid mesh) and also uses virtual mass (MFLUID + ELIST entries) and the user parameter VMOPT is set to 2, a SOL 103 analysis may fail with the following message:

Description

*** SYSTEM FATAL MESSAGE 5423 (MPYAD1) ATTEMPT TO MULTIPLY INCOMPATIBLE MATRICES FILE# COLS ROWS FORM TYPE NZWD DENS TRAILER FOR GAE IS 101 * * 2 2 * 100 TRAILER FOR PHSA IS 102 * * 2 2 * 10000 TRAILER FOR (NONE) IS 0 0 00000 where the * characters represnet numbers that are problem dependent. Avoidance: For V2005r3 (2005.5), insert the following DMAP alter: ECHOOFF $ COMPILE MODEFSRS NOLIST $ ALTER 'CALL.*MGEN2A','' $ IF ( VMOPT=2 AND NOCEE>0 ) CALL MGEN2A CASES,USET,GOA,GM,DRG,PHSA,LAMAS,CEE,MEE,GGE, BEC,MEC,LAMMATS,MIS,vafs/ MEH/

Known Error

CR 1-58536061 NASOUT $ PHSA,LAMAS UPDATED WITH VM EF ENDALTER $ $ COMPILE MGEN2A NOLIST $ ALTER 1,1 $ SUBDMAP MGEN2A CASES,USET,GOA,GM,DRG,PHSA,LAMAS,CEE,MEE,GGE, BEC,MEC,LAMMAT,MI,vafs/ MEA/ NASOUT $ ALTER 'MPYAD.*GAE','' $ DBSTATUS VAFS//S,N,NOVAFS $ EQUIVX PHSA/PHSFA/NOVAFS $ IF (NOVAFS>0) MERGE PHSA,,,,,VAFS/PHSFA/1 $ if explicit fluid is defined MPYAD GAE,PHSFA,/GEH/1 $ $ ENDALTER $ ECHOON $

For V2006r2 (MD R2) insert the following alter: ECHOOFF $ COMPILE MODEFSRS NOLIST $ ALTER 'CALL.*MGEN2A','' $ IF ( VMOPT=2 AND NOCEE>0 ) CALL MGEN2A CASES,USET,GOA,GM,DRG,PHSA,LAMAS,CEE,MEE,GGE, BEC,MEC,LAMMATS,MIS,THETAM,vafs/ MEH/ NASOUT $ PHSA,LAMAS UPDATED WITH VM EF ENDALTER $ $ COMPILE MGEN2A NOLIST $ ALTER 1,1 $ SUBDMAP MGEN2A CASES,USET,GOA,GM,DRG,PHSA,LAMAS,CEE,MEE,GGE, BEC,MEC,LAMMAT,MI,THETAM,vafs/ MEA/ NASOUT $ ALTER 'MPYAD.*GAE','' $ DBSTATUS VAFS//S,N,NOVAFS $ EQUIVX PHSA/PHSFA/NOVAFS $ IF (NOVAFS>0) MERGE PHSA,,,,,VAFS/PHSFA/1 $ if explicit fluid is defined MPYAD GAE,PHSFA,/GEH/1 $ $ ENDALTER $ ECHOON $ Known Error

CR 1-58549878

Known Error

CR 1-58549878

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

MFLUID - VMOPT,2 RVDOF - UFM 1126 (GNFIST) If a job defines virtual mass (MFLUID + ELIST) and the user parameter VMOPT is set to 2, if RVDOF entries are present the job may fail with the following message:

Description

*** USER FATAL MESSAGE 1126 (GNFIST) DMAP MODULE APPEND IS ATTEMPTING TO OUTPUT DATABLOCK 201 NAME = RVJ , WHICH ALREADY EXISTS. USER ACTION: DELETE THE DATABLOCK, OR USE FILE RVJ=OVRWRT Avoidance: Apply the following dmap alter: COMPILE PHASE1A NOLIST $ ALTER 'APPEND RVJ1','' $ APPEND RVJ1,PVMG/RVJ2 $ EQUIVX RVJ2/RVJ/-1 $ ENDALTER $

Known Error

CR 1-58564001

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SOL 400 - Roll out the open core with new MDLPRM parameter - SFM 6704 In SOL 400, if there is insufficient open core to allow the stiffness matrix decomposition, the job may fail with SYSTEM FATAL MESSAGE 6704.

Description

A new "MDLPRM,MINCORE,factor " to seclect the factor for which the open core data will be rolled out is implemented in MD R2.1. If the open data is rolled out, the whole open core will be available for decomposition.

Known Error

CR 1-58619601

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Description

Documentation/QRG - SOL 600 - MINSTAT The following changes should be made to the QRG descripton of the MINSTAT entry: 1) The NSET field is not needed for the MINSTAT bulk data entry because the Marc's INITIAL STATE (2,6) is not used.

Known Error

CR 1-58619601 It's only needed for the MCHSTAT bulk data entry. 2) There INIT1 and INIT2 fields in the "Format" section should be labled as INT1 and INT2.

Known Error

CR 1-58619657

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Documentation/QRG - SOL 600 - MCHSTAT There is an error in the QRG description of the MCHSTAT entry.

Description

The FILE field is described as follows: Enter the character string ELEM if IOPT=3. (Character, no Default; Required if IOPT=3) It should be: Enter the character string FILE if IOPT=3. (Character, no Default; Required if IOPT=3)

Known Error

CR 1-58713386

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SOL 700 - GP1, CORD2RX is ignored - UFM 2006 in GP1

Description

The CORD2RX entry is ignored in SOL 700, this will likelly lead to USER FATAL MESSAGE 2006 indicating an undefined coordinate system has been referenced.

Known Error

CR 1-58713429

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL 700 - Themal expansion coeff for MAT8 causes unexpected material failure the failure occurs in LsDyna. The MAT8 entry is correct in jid.dytr.dat. Quality will be re-assigened to Walter - E. Dickerson 9/25/2008

Description

When the thermal expansion coefficient for MAT8 entry is set to 0., elements may fail unexepctedly.

Known Error

CR 1-58746801

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3)

Known Error

CR 1-58746801

Abstract

Documentation/QRG - Incomplete complex force item codes(CELAS1) The complex force item code for the CELAS1 element in the QRG are missing and should be as follow:

Description

Item Code Item Real/Mag. or Imag/Phase 2 force RM 3 force IP

Known Error

CR 1-58787151

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Optimization - DRSPAN, CASI solver, MPC and rigid, multiple boundary conditions - UFM 5423 in MPYAD In a SOL 200 topology analysis, if SMETHOD=ELEM (CASI solver) and DRSPAN are used with multiple boundary conditions (SPC or MPC Case Control command) and either MPC or rigid elements are present then the run may fail with the message:

Description

*** USER FATAL MESSAGE 5423 (MPYAD) ATTEMPT TO MULTIPLY INCOMPATIBLE MATRICES FILE# COLS ROWS FORM TYPE NZWD DENS TRAILER FOR KLL IS 101 * * 62** TRAILER FOR UL IS 201 * * 22** TRAILER FOR PLI IS 102 * * 22** TRANSPOSE FLAG IS 0 where the * values are problem dependent. If no rigid elements or MPCs are present, the answers may be wrong for some subcases because the change in boundary conditions change is not properly handled. Avoidance: Use the SPARSE solver (remove the SMETHOD case control entry) or insert the following DMAP alter: compile fea,list $ alter 'if ( noul=-1 and nouset>0 ) CALL STATRS','' $ 131,131 $ if ( noul=-1 and nouset>0 ) then $ paraml pg//'trailer'/1/s,n,ncul $ if ( ncul=nloads ) then $

Known Error

CR 1-58787151 equivx pg/pg1/-1 $ only one boundary condition else $ np = nskip-1 $ matgen ,/col/6/ncul/np/nloads $ partn pg,col,/,,pg1,/1 $ delete /col,,,, $ endif $ ncul=nloads CALL STATRS LLL,KLL,PL,GPLS,USET,SILS,QR,MATPOOLs, EQEXINS,drg,dar,GM,,,LRSEQ,EDTs,CASES,Kgg,, kelm,kdict,bgpdts,cstms,mpts,dits,est,ys,pg1/ UL,crx,precon,epssex,qrg/ IRES/inrel/LUSETS/NSKIP/NLOADS/ norset/noa/PVALOLD/ADPTINDX/PEXIST/s,nullsol $ endif $

Known Error

CR 1-58837502

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Aeroelastic Analysis - AMP Module, PARAM,GUSTAERO - SFM 4276 EC 31 The presence of PARAM,GUSTAERO,-1 when using Strip Theory aerodynamics will cause the AMP module to fail with a System Fatal Message 4276, Error Code 31.

Description

Avoidance: Remove the PARAM,GUSTAERO,-1 Kevin, I recommend making this a limitation. However, Erwin Johnson should have a say on this too.

Known Error

CR 1-58951871

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SOL600 - MATT, TABLEM1 - translator writes incorrect temperature dependent material table

Description

The SOL 600 translator writes an incorrect temperature dependent material table. This will lead to wrong answers.

Known Error

CR 1-58984913

Product

MSC / MD Nastran

Corrected Version Abstract

Nonlinear Analysis - OLOAD RESULTANT output using geometrically updated load vectors

Known Error

CR 1-58984913 In SOL 106 and 400, the OLOAD RESULTANT is printed at the beginning of each subcase for the UNUPDATED geometry. For loads that change because of geometric deformations (PLOADi, FORCE2, etc.) the output does not match the SPCFORCE RESULTANT. The following DMAP will print the OLOAD RESULTANTS using force vectors based on the updated geometry.

Description

$ alter to print OLOAD in the updated geometric location to account for follower forces $ i.e FORCE1, PLOAD4, etc. $ this alter will print the OLOAD-NL RESULTANT just prior to the SPCFORCE RESULTANT. compile sedrcvr alter 'if.*PRTRESLT.*yes' IF (app='NLST' and NONLNR) THEN MESSAGE//'OLOAD base on FOLLOWER FORCE UPDATES' VECPLOT pj1,BGPDTN,SCSTM,CSTMS,CASEDR,,MEDGE,,/,pjRESx,pjHDx,,/ GRDPNT/S,N,ZERO/RESLTOPT/'OLOAD-NL'///ALTSHAPE//SEID $ ENDIF

Known Error

CR 1-59001648

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Nonlinear Analysis - RFORCE - UWM 6584 (RFORCD) followed by UFM 3003 SLT1 A sol 106 model with an RFORCE entry may fail with:

Description

*** USER WARNING MESSAGE 6584 (RFORCD) METHOD = 1 IS SPECIFIED ON THE RFORCE ENTRY IN COMBINATION WITH PELEMENTS. USER INFORMATION: METHOD = 1 DOES NOT YIELD CORRECT RESULTS WITH P-ELEMENTS AND/OR CONSISTENT(NON-LUMPED) MASS. *** SYSTEM FATAL MESSAGE 3003 (NLITER) ATTEMPT TO READ PAST THE END OF A LOGICAL RECORD IN DATA BLOCK SLT1 (FILE 113) IN SUBROUTINE NLSLTD Avoidance: The model that this was observed for had LOAD=1 and RFORCE

Known Error

CR 1-59001648 1. Changing to LOAD=11 and RFORCE 11 avoided the error. .

Known Error

CR 1-59166049

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Elements - CBAR, PBRSECT - Incorrect shear stress for Vz load

Description

The stress recovery for a CBAR element that references a PBRSECT entry is incorrect for VZ shear force.

Known Error

CR 1-59181381

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SOL 400 - 3D Contact with Bisection specified on the NLPARM entry will fail

Description

For SOL400, if there is 3D contact, the solution will fail if bisection is specified on the NLPARM entry.

Known Error

CR 1-59185711

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Superelements - EXTSEOUT, acoustic cavity, MDACMS - SFM 6143 If EXTSEOUT is requested with acoustic cavity in an external superelement and using MDACMS then the job will fail with SFM 6143:

Description

*** SYSTEM FATAL MESSAGE 6143 (UPARTPR) THE SIZES OF THE INPUT MATRICES AND THE DOF SETS ARE INCOMPATIBLE. SPECIFICALLY: The number of rows in VGFS is not equal to the size of the G-set User Information: Size of input matrix and DOF sets: VGFS : Rows= 3828 by Cols= 1 Set sizes: Major (G-set)= 4022 Set0 (A-set)= 258 Set1 (COMP-set)= 3764

Known Error

CR 1-59206949

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Elements - PBRSECT - Arbitrary Beam coordinate system incorrect, bending stress incorrect.

Description

Arbitrary beam produce incorrect bending stress data recovery.

Known Error

CR 1-59215380

Known Error

CR 1-59215380

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Elements - PBRSECT - Stress recovery stress tensor mapping leads to wrong vonmises in Patran The MSC.Nastran 2005R3 Release Guide for arbitrary beam cross sections has the following mapping. (Chapter 4, Arbitrary Beam Cross-Section, subsection "stress recovery for whole cross-section")

Description

Op2 Stress Tensor | Recovered ABCS Direct Stress Sx | Sx Sy | Sxy Sxy | Szx This mapping will lead to incorrect stress derivations when the op2 is read into Patran. and it is non-intuitive that the stresses displayed in Patran are not what you think they should be. The op2 file should contain a direct mapping so that patran post-processing will be correct.

Known Error

CR 1-59225891

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

SOL 400 - SDR2 - SOL 400 jobs may fail on SGIR14K SOL 400 jobs may fail on SGI Irix systems in the SDR2 module during data recovery.

Description Avoidance: Other than running on a different platform, there is no avoidance. Known Error

CR 1-59287753

Product

MSC / MD Nastran

Corrected Version Abstract

External Superelements - EXTERSE - DTI,TUG1 in residual causes UFM 5423 MPYAD1

Description

If DTI,TUG1 or DTI,TES1, or DTI,TEF1, or DTI,TQG1 are present in the residual structure, then EXTERSE will be set to TRUE and improper processing in SEDRCVR will generate the following error: *** SYSTEM FATAL MESSAGE 5423 (MPYAD1) ATTEMPT TO MULTIPLY INCOMPATIBLE MATRICES

Known Error

CR 1-59287753 FILE# COLS ROWS FORM TYPE NZWD DENS TRAILER FOR MUG1 IS 101 60 60 1 2 2 167 TRAILER FOR ULS1 IS 102 5 30 2 2 60 10000 TRAILER FOR (NONE) IS 0 0 00000 TRANSPOSE FLAG IS 0 Avoidances: 1) Remove DTI entries described above 2) Insert the following DMAP ALTER: $ IF user removes the BEGIN SUPER and treats the DMIG as a DMIG $ instead of an external SE, then an error can occur trying to process DRMH3. $ to avoid this, only mark EXTERSE as TRUE when NOTUG, NOTES, NOTEF, NOTQG $ exist for SEID that are >0 compile super3,nolist alter 'exterse=','exterse=' IF(SEID>0) EXTERSE=(SETYPE='EXTRNA' OR SETYPE='EXTRNG' OR NOTUG OR NOTES OR NOTEF OR NOTQG) $

Known Error

CR 1-59294257

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Description

Acoustic Analysis - PFMODE, PFPANEL - Output may be wrong with a "phase" request. PFMODE and PFPANEL case control commands that request PHASE output may result in incorrect output. Avoidance: Request only REAL, IMAG output.

Known Error

CR 1-59419426

Product

MSC / MD Nastran

Corrected Version GL Abstract Description

SOL 600 - NLAUTO is not effective to control time stepping if MCHSTAT is also used The following scenario will result in the NLAUTO entry not controlling the time stepping:

Known Error

CR 1-59419426 1. Run a SOL 600, 159 (transient thermal anlaysis), and get temperatures in t16 file. 2. Run a SOL 600, 106 (static structural analysis) using initial temperature and temperature load of the t16 file from step 1. In the second run, NLAUTO is used to control time stepping, but it is not effective to control time stepping since the translator uses "AUTO THERM" instead of "AUTO STEP" ignoring parameters defined on the NLAUTO entry such as total time. "NLAUTO" should be tranlated into "AUTO STEP" in marc.dat as written in Quick Reference Guide while "MTHERM" is translated into "AUTO THERM" in marc.dat.

Known Error

CR 1-59529106

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

Connection Elements - CINTC on curved geometry does not pass GROUNDCHECK or PARAM CHECKOUT YES A model with curved geometry (a cylinder for example) and a CINTC line interface will fail the GROUNDCHECK at the NSET level. Other indications are EMH is not null from PARAM,CHECKOUT, YES. The CINTC algorithm must be refined to preserve the rigid-body modes, while retaining the flexibility of CINTC connection. CINTC is not going to be modified, Glued Contact can be used instead.

Known Error

CR 1-59626733

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

Optimization/Design Sensitivity - Superelements, PCOMP, PCOMPG - may fail in cmpzpr

Description

Module cmpzpr uses system cell 93 (NPCOMP) to store the number of PCOMP/PCOMPG bulk data entries.. In general, this is not a problem for list superelements. However, for part superelements, it is possible that each part has its own NPCOMP. When cmpzpr reserves memory space in opencore based on NPCOMP in system cell 93, the job may fail if the NPCOMP is not equal to the actual NPCOMP of a part se. This is only a potential problem in SOL 200.

Known Error

CR 1-59682791

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract Description

SOL 600 - PBEAM - Large field format may fail in SOL 600 for PBEAM PBEAM large field format may fail in SOL 600 for certain combinations of input. Avoidance: Use small field format.

Known Error

CR 1-59690996

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Documentation/QRG - RBJOINT - SOL 700 Only, Should not be in MSC.Nastran QRG.

Description

The RBJOINT is a SOL 700 only entry and it should not be included in the MSC.Nastran QRG.

Known Error

CR 1-59692231

Product

MSC / MD Nastran

Corrected Version Abstract

Buckling - buckling or preload subcase with boundary condition change Inefficient In SOL 105, if the buckling or preload subcase is specified with a change in the boundary condition then an uncessary matrix decomposition will be performed. Avoidance: Insert the following DMAP alter:

Description

compile phase1dr alter 'call phase1c'(,-1) PARAML CASEw//'DTI'/1/256//S,N,STATSuB $ PARAML CASEw//'DTI'/1/241//S,N,STATpre $ if ( statsub=0 and statpre=0 ) then $ alter 'call phase1c' endif $

Known Error

CR 1-59715698

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Eigenvalue Analysis - CGAP - UFM 4016 (TA1ETD)

Description

Nastran 2005r3 and earlier releases may fail with the message: USER FATAL MESSAGE 4016 (TA1ETD) when an eigenvalue analyis contains gap elements and TEMP entries.

Known Error

CR 1-59715698 Avoidance: Include a TEMPD entry.

Known Error

CR 1-59796301

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Complex Eigenvalues - SOL 110 with ACMS produced wrong answers with K2PP, M2PP, B2PP or TFL If K2PP, M2PP, and B2PP are used in SOL 110 along with ACMS then the run will produce wrong answers. Avoidance: Insert the following DMAP alter

Description

compile semceig alter 'dbdelete datablk=vgdr','' delete /vgdr,,,, $ compile fdrmgen alter 'return'(2),'' if ( app='ceigen' and not(mdreig) ) return $ compile spdr1 alter 'return'(2),'' endalter

Known Error

CR 1-59863480

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Documentation/QRG - DMP, Param,POST,-5

Description

DMP geometric doman and frequency domain do not support param,post,5.

Known Error

CR 1-59906396

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Description

Aeroelastic Analysis - CAERO1, MONCNCM - Tolerance is too tight The moncncm entry provides output on aeroelastic strips. the logic for determining whether aero boxes share a strip has been found to incorrectly designate more strips than intended. this has been traced to a tolerance that is too tight for the accuracy that is available from the input bdf file. User Avoidance: Check the CAERO1 entries to check that abutting panels are aligned exactly

Known Error

CR 1-59911241

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Linear Contact - Missing Message when solution does not converge. Linear contact in SOL 101 does not issue a fatal message if it does not converge. A message similar to that issued in SOL 400 shown below needs to be added. *** USER FATAL MESSAGE 4551 (nl3con)

Description

*** STOPPED PROBLEM DUE TO FAILED CONVERGENCE. NJ Teng; 07/29/10 Now we have issued the same FATAL message in SOL 101 contact jobs upon solution divergence.

Known Error

CR 1-59955051

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

FRF - CONM2 - SFM 307 in FRFINFO module

Description

An FRF generation run with stress requests and CONM2 elements fails with the message: SYSTEM FATAL MESSAGE 307 in the FRFINFO module.

Known Error

CR 1-59961781

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

SOL 700 - D2RAUTO is not translated.

Description

The D2RAUTO entry is not translated to the dytr.dat file and there are no warning messages.

Known Error

CR 1-60037683

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Description

FRF - PLOTEL entries result in SFM 3200 (Logic Error 27) in FRFINFO module An FRF generation run with PLOTEL entries and a stress request for a nonexistent element fails with the message: SYSTEM FATAL MESSAGE 3200 (Logic Error 27) in the FRFINFO module. Avoidance: Add a stress or force output request for a valid element

Known Error

CR 1-60037787

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

FRF - PLOTEL entries result in SFM 3200 (Logic Error 12) in FRFINFO module

Description

An FRF generation run with PLOTEL entries and no stress or force output requests fails with the message SYSTEM FATAL MESSAGE 3200 (Logic Error 12) in the FRFINFO module. Avoidance: Add a stress or force output request for a valid element

Known Error

CR 1-60162658

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Description

SOL 600 - Multiple MOMENT or FORCE entries for the same grid leads to incorrect loads For all versions of SOL600 (through mdr2 and v2007), when multiple MOMENT or FORCE entries for the SAME grid are combined using the LOAD Bulk Data Entry, there is a problem during translation that leads to incorrect loads. Avoidance: To get the correct results using current SOL 600, all moments and forces at the same grid which are applied in the same load case must be combined onto one FORCE or MOMENT entry.

Known Error

CR 1-60164831

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

SOL 400 - Hybrid Damping is not implemeted into SOL400 correctly.

Description

The Hybrid Damping for the transient analysis is implemented in SOL129. It is found that this damping is not implemented correctely in SOL 400.

Known Error

CR 1-60164849

Product

MSC / MD Nastran

Corrected Version 2007.1.0 Abstract

SOL 400 - NOLIN2 - UFM, Fails to converge

Description

SOL 400 will diverge if there are NOLIN2 entries in the model together with 'PARAM,TSTATIC,1"

Known Error

CR 1-60165121

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

SOL 400 - Iterative Solver, SMETHOD, MPC - tpl nlc006a_casi, fails to coverge

Known Error

CR 1-60165121 on i8 SOL 400 with rigid elements and/or mpcs using the Casi iterative solver may fail to converge on i8 systems leading to the following messages. This error was discovered with tpl problem nlc006a_casi on ia64 systems. This error has been corrected in MD R2.1.1(version 2007.1.1) which has been posted to the product update web site at: http://www.mscsoftware.com/support/software_updates/mdr211.cfm

Description

*** SYSTEM INFORMATION MESSAGE 4172 (ITSCAS) CASI ITERATIVE SOLVER SOLUTION ERROR ESTIMATION STATISTICS FOLLOW FOR LOAD CASE NUMBER: 1 INPUT ERROR CONVERGENCE EPSILON VALUE = 1.000000E-04 REDUCTION IN 2-NORM OF THE RESIDUAL = 7.239659E-05 REDUCTION IN INFINITY NORM OF THE RESIDUAL = 3.959844E-05 REDUCTION IN PRECONDITIONED NORM OF RESIDUAL = 1.012917E-04 ESTIMATE OF NORMALIZED ENERGY NORM OF ERROR = 2.811392E-04 *** USER WARNING MESSAGE 4675 (NMEPS) EXCESSIVE INCREMENTAL LOAD IS APPLIED IN ELEMENT ID = 201 REDUCE THE LOAD INCREMENT BY A FACTOR OF 2.747758E+02 FOR BETTER SOLUTION . *** USER FATAL MESSAGE 4676 (NMEPS) ERROR EXCEEDS 2.000000E+01 PERCENT OF YIELD STRESS IN ELEMENT ID=201 *** USER WARNING MESSAGE 4675 (NMEPS) EXCESSIVE INCREMENTAL LOAD IS APPLIED IN ELEMENT ID = 1001 REDUCE THE LOAD INCREMENT BY A FACTOR OF 1.434823E+02 FOR BETTER SOLUTION . *** USER FATAL MESSAGE 4676 (NMEPS) ERROR EXCEEDS 2.000000E+01 PERCENT OF YIELD STRESS IN ELEMENT ID=1001

Known Error

CR 1-60222617

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Aeroelastic Analysis - MONITOR=ALL results in Complex Data Output A request for MONITOR point output should result in REAL/IMAGINARY output by default as the Quick Reference Guide states. However, the request:

Description

MONITOR=ALL is the same as MONITOR(PHASE)=ALL.

Known Error

CR 1-60222617 Avoidance: To obtain the REAL/IMAGINARY output, one must specify MONITOR(REAL)=ALL.

Known Error

CR 1-60302368

Product

MSC / MD Nastran

Corrected Version GL Abstract

ILP64: SOL 400 - TA1M - FATAL NON-LINEAR ELEMENT ERROR on Solaris mode=i8

Description

SOL 400 jobs, such as TPL test nclevrbm.dat, may fail in the TA!M module on to Solaris ilp64 (a.k.a i8) system with the message FATAL NON-LINEAR ELEMENT ERROR.

Known Error

CR 1-60303381

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Eigenvalue Analysis - Modal analysis with ACMS and F1>0.0 may yield results outside the range If the F1 field on the EIGRL bulk data entry is greater than 0.0, ACMS will ignore the F1 entry and possibly produce eigenvalues between 0.0Hz and "F1" Hertz.

Description

Avoidance: Insert the following DMAP alter. compile invlan alter 'ufmin\-1 ) mce2 uset,gm,mgg,k4gg,bgg,/mnn,k4nn,bnn, $ if ( nooset>-1 ) vec uset/vno/'n'/'o' $ call getxay mnn ,vny,vno,vna,goy,goa/may/nooset $ call getxay bnn ,vny,vno,vna,goy,goa/bay/nooset $ call getxay k4nn,vny,vno,vna,goy,goa/k4ay/nooset $

Known Error

CR 1-62110416

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

PARAM CDITER should issue FATAL message in all SOLs except SOL 101

Description

If PARAM,CDITER is requested in a static solution other than SOL 101, then incorrect answers may occur. For example, SOL 103 with STATSUB or SOL 105 will result in wrong anwers if used in conjunction with PARAM,CDITER. Avoidance: None. In SOL 200 (V2010), there is an SSSAlter available called cditer_200a.alt

Known Error

CR 1-62110416 in MD 2010, the nonlinear optimization feature supports general contact.

Known Error

CR 1-62121335

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Frequency Response - SOL 111, multiple SPCD subcases, STATSUB - Wrong answers If multiple enforced motion subcases and a preload subcase are specfied in SOL 111 then then the run will produce wrong answers. Avoidance: Insert the following DMAP alter:

Description

compile phase0 alter 'lcgen casers,slt,ett,dynamic0,geom4s' paraml casers//'trai'/1/s,n,norec $ if ( norec>1 and isolapp=2 ) then $ irec=2 $ start with second record do while ( irec 0 ) THEN $ Known Error

CR 1-65561133

Product

MSC / MD Nastran

Corrected Version 2010.1.1 Abstract

Acoustic Analysis - ACMS, MFLUID, PARAM,VMOPT,2 - wrong answers in coupled response

Known Error

CR 1-65561133 If a coupled response analysis is carried out on a model containing an explicit fluid mesh (acoustic cavity mesh) and a structure in which the virtual mass method is also used (MFLUID Case Control and ELIST Bulk Data), while using PARAM,VMOPT,2 then the answers will be wrong.

Description

Avoidance: Set PARAM,SPARSEPH,NO and insert the following DMAP alter: COMPILE GMAM NOLIST $ ALTER 'CALL.*MDDTOH'(,-1) $ TYPE PARM,NDDL,I,Y,VMOPT $ IF (VMOPT=2) REDOPT=1 $ ENDALTER $

Known Error

CR 1-65662259

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Documentation/QRG - SOL 600 Continue option is incorrect

Description

The SOL 600 entry CONTINUE options 3-5 are not supported and will be removed from the QRG.

Known Error

CR 1-65699319

Product

MSC / MD Nastran

Corrected Version Abstract

Rigid body doesn't move in 3D contact. 1. In 3D contact, moving a rigid body (plane surface) with position control, BCBODY/CONTROL=-1, fails. The rigid-body surface does not seem to move.

Description

2. Use velocity control instead or moving the rigid-surface a bit away from the deformable body works. 3. Avoidance a. Use velocity control, CONTROL=0; b. Still use position control, but move the rigid surface a bit away from the deformable body.

Known Error

CR 1-65900127

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Optimization/Design Sensitivity - DSAPRT does not print associated subcases for DRESP3

Description

DSAPRT does not print associated subcases for DRESP3

Known Error

CR 1-65930441

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

SOL 400 - DMAP modification fails with SFA 427 - LOPBLK table has exceeded its maximum entries

Description

When modifying the SOL 400 DMAP with addtional DO-WHILE loops, the job will fail with SFA 427 - The LOPBLK tabe has exceeded its maximum 1200 number of entries.

Known Error

CR 1-65936901

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

ILP64: SOL 400, Linear Contact - SFM 4192 with mode=i8 TPL test deck cnt2super which demonstrates linear contact in SOL 101 wil fail on ILP64 (a.k.a. i8) systems with the message:

Description

^^^ PHASE 1 - SUPERELEMENT GENERATION, ASSEMBLY AND REDUCTION. *** SYSTEM FATAL MESSAGE 4192 (SEMA) GRID POINT 20 IN SUPERELEMENT 0 IS NOT DEFINED IN BGPDT FOR DOWNSTREAM SUPERELEMENT *** SYSTEM FATAL MESSAGE 4192 (SEMA)

Known Error

CR 1-65937261

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

SOL 400 - BCONTACT - Position control of rigid body is incorrect

Description

In SOL 400 if a deformable body and a rigid body are in initial contact, the position control is incorrect.

Known Error

CR 1-65983571

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Numerical Methods - DCMP - Signal 11, Segmentation Violation

Description

The combination of low available Open Core memory and large Nastran BUFFSIZE may lead to a Segmentation Violation (Signal 11) in the DCMP or READ modules during matrix factorization. This non-standard termination causes Nastran to halt with no Fatal message. Error messages generated by the operating system may appear in the log file.

Known Error

CR 1-65983571 Avoidance: There are two potential avoidances: 1. Increase memory via the "mem=" command line keyword. 2. Reduce the BUFFSIZE.

Known Error

CR 1-66004372

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

DBC - CMASS, CFAST- SFM 6062 (DBC) on ilp64 (i8) systems CMASS and/or CFAST elements may lead to the following fatal message on ilp64 (i8) systems when param,post,0 is specified.

Description

*** SYSTEM FATAL MESSAGE 6062 (DBC) *** DIOMSG ERROR MESSAGE 19 FROM SUBROUTINE BLKFIX OBJECT PFAST ENTRY LENGTH AND DATA DEFINITION IS INCONSISTENT FOR HETEROGENOUS OPERATIONS. TRANSMIT AND RECEIVE MUST BE USED TO MIGRATE XDB BETWEEN PLATFORMS.

Known Error

CR 1-66013381

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

SOL 600 - Marc's parameter option LUMP will not be applied in transient heat transfer analysis According to the MD Nastran R2.1 Quick Reference Guide, the "PARAM,MARCLUMP,0 or 1 selects whetherr the lumped specific heat matrix will be used in a transient SOL 600 heat transfer analyses. However, marc's parameter option LUMP will not be applied in transient heat transfer analysis and a consistent specific heat matrix will be used.

Description

***2009/4/1 ANAYAMA*** As shouwn below, PARAM,MARCLUMP is "only used with dynamic analysis". Nolonger works with heat transfer. Ref. MD Nastran R3 Quick Reference Guide or MD Nastran R4 (BETA) Quick Reference Guide March 12, 2009 MARCLUMP Default = 0, SOL 600 only. Integer, Default = 0, MD Nastran Implicit Nonlinear (SOL 600) only.

Known Error

CR 1-66013381 0 Consistent mass will be used for SOL 600 transient dynamics or eigenvalue problems with rotational masses (if applicable). 1 Lumped mass will be used for SOL 600 transient dynamics or eigenvalue problems with rotational masses (if applicable). 2 Consistent mass will be used for SOL 600 transient dynamics or eigenvalue problems without rotational masses. 3 Lumped mass will be used for SOL 600 transient dynamics or eigenvalue problems without rotational masses. Remark: This parameter is only used with dynamic analysis.

Known Error

CR 1-66013451

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

SOL 600 - NLHEATC entry is not translated The NLHEATC entry is not translated for SOL 600 transient heat transfer analysis. it is only translated for steady state heat transfer analyisis.

Description

***2009/4/1 ANAYAMA NLHEATC entries in transient heat transfer analyses worked with MD Nastran R4 Beta1 Release, Version 2009.0.0, MAR 10, 2009.

Known Error

CR 1-66026575

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Optimization - DSAD - BIOMSG: ERROR 3001 HAS OCCURRED IN ROUTINE GREAD The DSAD module attempts to identify grid id's on the dresp1 entry that do not exist. If the missiing grid is called out in the final subcase and there are no other grids invoked by this subcase, the message:

Description

BIOMSG: ERROR 3001 HAS OCCURRED IN ROUTINE GREAD , FILE INDEX = 0. wil be output from the DSAD module. Avoidance: When the above message occurs in the DSAD module, a check should be made to inusre that all the GRID id's referenced on DRESP1 entries exist.

Known Error

CR 1-66026799

Product

MSC / MD Nastran

Known Error

CR 1-66026799

Corrected Version 2008.0.0 (MD R3) Abstract

Optimization/Design Sensitivity - DRSPAN, DESGLB and DESSUB may fail in dsad module - SFM 6926 A SOL 200 job with DRSPAN and DESGLB/DESSUB that point to the same constraint set may fail in the DSAD module with SFM 6296 unable to allocate a data block.

Description Avodiance: This is a user input error which can be avoided by removing the desglb command in the case control. The presence of drspan turns off the checking logic for usage of DRESP1 in DESGLB. The checking logic should be active for those DRESP1s that have nothing to do with DRSPAN. Known Error

CR 1-66194316

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL 200 job with DRESP3 having multiple spaces between arguments in USRDATA may fail with UFM 316 SOl 200 optimization job with DRESP3 with USRDATA option has multiple spaces between arguments may fail with following UFM 316.

Description

*** USER FATAL MESSAGE 316 (IFPDRV) ILLEGAL DATA ON BULK DATA ENTRY DRESP3 Avoidance: use a single space between USRDATA arguments.

Known Error

CR 1-66195125

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Dynamic Analysis - EPOINTs and DELAY entries in dynamic response, wrong answers, UWM 4193 (DPD7) If a model contains EPOINTs where at least one EPOINT has an id lower than a loaded GRID point and the model contains DELAY entries, the answers may be wrong.

Description

The f06 file contains the warning message: *** USER WARNING MESSAGE 4193 (DPD7) NO EXCITATION HAS BEEN SPECIFIED FOR ANY OF THE COMPONENTS SPECIFIED ON DELAY SET X REFERENCED ON TLOADi ENTRY X where X are integer values.

Known Error

CR 1-66195125 Avoidance: Renumber the epoints. Ensure the EPOINT ids are always higher than the largest GRID poiint or SPOINT ids.

Known Error

CR 1-66224284

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Aeroelastic Analysis - SPLINE, SPRELAX, SPBLNDi - Incorrect Results There are two errors that affect spline processing with the spline relax feature and the spline blend feature.

Description

1. If the blend region does not cover the entire overlap region, the splines are averaged in the unblended area when they should take their value from: f_1(x) = 1 and f_2(x) = 0 for x < -D1 f_1(x) = 0 and f_2(x) = 1 for x > D2 2. If the same spline is relaxed on two different SPRELAX entries it is possible that neither is entry is processed.

Known Error

CR 1-66226424

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Description

Aeroelastic Analysis - No velocity input on a AERO entry leads to wrong answers or poor message In aeroelastic analysis if the user neglects to specify a velocity value on the AERO bulk data entry the analysis may fail with the message below or wrong answers may be produced. The FPU has been reset after floating point exception

Known Error

CR 1-66267651

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Description

Optimization/Design Sensitivity - PBMSECT - UFM 7602 (DOPR1I) with arbitrary beasm cross section SOL 200 with arbitrary beam cross sections, PBMSECT, may encounter the message: USER FATAL MESSAGE 7602 (DOPR1I)

Known Error

CR 1-66309821

Known Error

CR 1-66309821

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Acoustic Analysis - GP5 issues UIM 6207 with null method type

Description

The GP5 module issues USER INFORMATION MESSAGE 6207 when there is no ACMODL bulk data entry defined. The message is supposed to indicate the method that will be used, but the field is blank becuase it has not been initialized prior to the message being issued.

Known Error

CR 1-66309911

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Dynamic Analysis - MCFRACTION output incorrect when MODESELECT used

Description

When the MODESELECT case control command is used to select modes to be used in the modal analysis and the MCFRACTION command is also present in the case control, the structure's natural frequency value in the MCFRACTION output may be incorrect. The value is wrong if the number of modes selected is less than the number of modes actually found in the eigenvalue analysis. The mode number is correct when it is only the natural frequncy value that is wrong.

Known Error

CR 1-66380596

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Elements - bar/beam library, part superelements - UWM 73(PRGWHR) If PBARL or PBEAML are present in part superlements then the following warning message will be issued and can safely be ignored.

Description

*** USER WARNING MESSAGE 73 (PRGWHR) THE DBVIEW PARAMETER NAMED ARBMID IS UNDEFINED LOCALLY *** COMPILATION DIAGNOSTIC INFORMATION *** 1. STATEMENT TYPE: WHERE CLAUSE 2. CLAUSE: ARBMID>0 AND (PEID=4 AND DESITER=0 AND PVALID=0 AND APRCH=' ' AND HIGHQUAL=0 AND AUXMID=0 AND DESINC =0 AND DISCRETE=FALSE AND DBLOCFRM=' ') Avoidance: None

Known Error

CR 1-66384331

Known Error

CR 1-66384331

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Acoustic Analysis - PFMODE case control commdand STRUCTMP keyword

Description

The PFMODE case control command requests modal participation factor output (MPF). The format of the command allows for specification of either STRUCTURE or FLUID. The STRUCTURE option produces structural MPF output using structural natural frequencies. The FLUID option produces acoustic MPF output using structural natural frequencies for acoustic structure MPF and fluid natural frequncies for acoustic fluid and panel MPF. For both cases, the STRUCTMP keyword is used to define the number of structural modes that are used during MPF calculations. When both PFMODE(STRUCTURE...) and PFMODE(FLUID...) are present in the input case control, the STRUCTMP keyword is not interpreted according to the QRG description. Rather, the value used in the structure MPF computations is the maximum of the STRUCTMP keyword values supplied in the two commands.

Known Error

CR 1-66435501

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

Matrix Methods - Large Frequency Response Model, UFM 6062 and "Access violation" Matrix Methods - Large Frequency Response Model, UFM 6062 and "Access violation" error. *** SYSTEM FATAL MESSAGE 6062 (DBC) *** DIOMSG ERROR MESSAGE 6 FROM SUBROUTINE WRTLST OVERFLOW OF DICTIONARY PRIMARY INDEX FOR DATA BASE UNIT 1. Possible avoidance: use NASTRAN DBCFACT = 4 Fixed in MD2010.

Known Error

CR 1-66552807

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Acoustics - CHACAB - Incorrect mass for 16 node element

Description

The mass matrix for the 16 node CHACAB acoustic barrier element is not correct.

Known Error

CR 1-66580568

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

RIGID=LAGRANGE in sol 101 produces no mpc forces

Description

When RIGID=LAGRANGE is set in a sol 101 run and mpc forces are requested, no mpc forces are calculated. A sample deck, test_mpc_forces.bdf, is provided to duplicate the problem. test_mpc_forces.bdf includes requests for mpcforces=all and rigid=lagrange and it produces no mpc force output in the .f06. The MAXIMUM MPCFORCES output also is all zero. If you take the RIGID=LAGRANGE card out of test_mpc_forces.bdf, then mpc forces are calculated properly. The only current work around is to pull the mpc force data from the gpforce output.

Known Error

CR 1-66624921

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract Description

Eigenvalue Analysis - NLRSFD - UFM (DPD4) for entry that should be ignored An incorrect NLRSFD entry in eigenvalue analyis will cause the DPD4 module to be executed and a User Fatal Message to be issued. Avoidance: Correct the entry.

Known Error

CR 1-66661307

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

SOL 600 - ISTRESS not honored - Wrong Answers

Description

The NASTRAN ISTRESS is not translated into the Marc input file and the job runs to completion without warning yielding results without the ISTRESS effects.

Known Error

CR 1-66677787

Product

MSC / MD Nastran

Corrected Version Abstract

Description

Superelments - CINTC Elements with Superelements, UIM 3017, Run Terminates CINTC element is not supported in superelements. It must be in the residual structure. A message is issued in GP4 when Nastran processes CINTC in superelements

Known Error

CR 1-66677787 as *** USER INFORMATION MESSAGE 3017 (GP4) NO MESSAGE FOR MESSAGE NO. = 0 PARAMETERS = 0 1381256777 538980934 This message is obviously not adequate. A clear message should be issued for this matter. Avoidance: Do not put CINTC element in the superelements.

Known Error

CR 1-66713627

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Postprocessing - Nastran PlotPs utility doesn't work in 2007r1 Nastran .plt files generated when mode=i8 is in effect do not work with the standard plotps utility program because mode=i8 runs can only recognize and read 32-bit .plt files generated on the same platform. Avoidance: Install the attached "plotps_i8" file into MSC_BASE/MSC_VERSD/MSC_ARCH/plotps_i8 and run with:

Description

md20071 plotps_i8_ia64 JOB.plt Problem Resolution: Starting with MD Nastran 2010, a new utility, mscplotps, is being delivered that will read .plt files generated on any platform (big-endian or littleendian) and with any word length (mode=i4 or mode=i8). Also, .ps files may now be generated directly by Nastran by specifying FORM=FORMATTED on an ASSIGN PLOT statement.

Known Error

CR 1-66825861

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Optimization/Design Sensitivity - DSAD - Eigenvector Contraints, SFM GREAD

Description

A SOL 200 job with eigenvector constraints combined with other analysis types may fail in the DSAD module with an error during GREAD.

Known Error

CR 1-66825861 Avodiance: None. If possible, run SOL 200 job with mode and eigenvector constraints only.

Known Error

CR 1-66833371

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Connect Elements - CWELD, CFAST, CQUAD4, CQUAD8 - UFM 7632 (EWLDPD) If CWELD or CFAST elements are used to connect a patch of CQUAD4 elements with CQUAD8 the following fatal message may be issued:

Description

*** USER FATAL MESSAGE 7632 (EWLDPD) FOR CWELD ELEMENT ID= 102, A CONNECTION TO ONE OF THE SHELL SURFACES CANNOT BE MADE. USER INFORMATION: THE FIRST THREE SHELL GRIDS ARE 51 53 61 *** USER FATAL MESSAGE 2026 (EMG) ELEMENT 102 GEOMETRY YIELDS UNREASONABLE MATRIX. ^^^ USER WARNING MESSAGE 9031 (ERRPH1) ^^^ NOGO ENCOUNTERED IN SUBDMAP SEMG

Known Error

CR 1-66856588

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

CBUSH linear format strain is missing The linear strain output format is missing for the CBUSH element.

Description Fixed in 2010. Known Error

CR 1-66916611

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Description

Optimization/Design Sensitivity - ECHO NEWBULK - Incorrect punched bulk data A SOL 200 model with DVGRID and ECHO = PUNCH(NEWBULK) may contain incorrect information in the punched bulk data deck. Avoidance: The output produced using the despch parameters is correct and can be used to construct a new bulk data deck.

Known Error

CR 1-66918399

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Documentation/QRG - BCTABLE

Description

In the MDR2 QRG, the description of the BCTABLE entry indicates that it is for SOL100, it should indicate SOL 101.

Known Error

CR 1-66941791

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

External Superelements and Acoustics - C-set - SFM 6144 (PARTN1PR) An external superelement creation with an acoustic cavity and C-set will result in SFM 6144 (PARTN1PR):

Description

*** SYSTEM FATAL MESSAGE 6144 (PARTN1PR) THE SIZES OF THE INPUT MATRICES AND PARTITIONING VECTORS ARE INCOMPATIBLE. SPECIFICALLY: The number of columns in KOA is not equal to the number of rows in the column partitioning vector VFT User Information: Size of input matrix and partitioning vectors: KOA : Rows= 4443394 by Cols= 2561 VFT : Rows= 562 VFO : Rows= 4443394 Avoidance: Insert the following DMAP alter: compile semr3 alter 'vfo',''(2) partn koa,vafs,vofs/,,,kotf/1 $ endalter

Known Error

CR 1-66953461

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

SOL 400 - RIGID=LINEAR - SFM 4370 (SDCPRF)

Description

SOL 400 with RIGID=LINEAR may fail with SYTEM FATAL MESSAGE 4370 (SDCPRF)

Known Error

CR 1-66984621

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3)

Known Error

CR 1-66984621

Abstract

Connector Elements - MODGM2, CWELD, CFAST, PARAM,CHKRUN,2 does not funciton correctly

Description

An analysis with CWELD and/or CFAST elements will not be stopped after checking the connector elements when PARAM,CHKRUN,2 is set.

Known Error

CR 1-66988471

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Virtual Mass - PARAM,SOLVIT,YES + PARAM,VMOPT,2 does unnecessary DECOMP of CEE In a dynamic analysis, if MFLUID and ELIST entries are present to model virtual mass and the iterative solver is selected, the solution performs an unnecessary expensive factorization of the CEE matrix. Avoidance: Insert the following DMAP alter.

Description

ECHOOFF $ COMPILE VMDEC NOLIST $ $ ALTER 'PARAML.*USET','' $ TYPE PARM,,CHAR8,Y,SOLVIT='NO' $ TYPE PARM,,I,N,NP $ $ ALTER 'PUTSYS.*209'(,-1) $ IF (SOLVIT='YES' AND GETSYS(NP,216)=1) RETURN $ ENDALTER $ ECHOON $

Known Error

CR 1-67131007

Product

MSC / MD Nastran

Corrected Version

2007.1.1

Abstract

Submittal - mem=estimate does not work after updating MSC.Nastran to version 2007.1.1 After updating MSC.Nastran 2007.0.0 to 2007.1.1 (2007 r1a) by installing the update from: http://www.mscsoftware.com/support/software_updates/nastran200711.cfm

Description a Nastran job with mem=estimate will output the following error messages: nastran instest.dat mem=estimate

Known Error

CR 1-67131007 MSC.Nastran V2007.1 (Intel Windows .NET 5.2 (Build 3790)) Thu Dec 20 10:55:55 2007 *** SYSTEM INFORMATION MESSAGE (pgm: nastran, fn: estimate_job_requirements) Starting ESTIMATE, please wait... *** SYSTEM FATAL MESSAGE (pgm: estimate, fn: main) MSC.Nastran Version 2007.1 is not supported. Supported releases: 68.2, 70.7, 2001.0, 2004.0, 2004.5, 2005.0, 2005.5, 2006.0, 2007.0 *** SYSTEM WARNING MESSAGE (pgm: nastran, fn: estimate_job_requirements) a.estimate=c:/msc.software/msc.nastran/2007r1a/msc20071/i386/estimate.exe (program default) ESTIMATE processing failed. *** SYSTEM INFORMATION MESSAGE (pgm: nastran, fn: estimate_job_requirements) Assuming "memory=8MW" as specified by the "memorydefault" keyword. Avoidance: A compatible estimate program has been put to the product update site. MSC.Nastran beginning job instest.

Known Error

CR 1-67131791

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

AUTOMSET - RBE3 - SFM 4276 (BLDPRD) A simulation with RBE3’s that incorrectly define degrees of freedom as dependent and independent produces the follwing unsatisfactory fatal message if used with AUTOMSET (PARAM,AUTOMSET,YES).

Description

Known Error

*** SYSTEM FATAL MESSAGE 4276 (BLDPRD) ERROR CODE 211 PID= 0 *** USER INFORMATION MESSAGE 4276 (BLDPRD) THE DIAG 44 RELATED A NASTRAN DUMP IS SENT TO LOG FILE. USER ACTION: THIS INFORMATION MAY BE USEFUL TO MSC FOR DEBUGGING YOUR PROBLEM. PLEASE CONTACT MSC CLIENT SUPPORT. CR 1-67191021

Known Error

CR 1-67191021

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

External Superelement - DMIGPCH - BIOMSG: ERROR 201 During an assembly run using the external superelement feature, the job may fail with the following unclear message in IFP if the DMIGPCH option and data recovery is requested for the external superelement. This error is fixed in MDR3. BIOMSG: ERROR 201 HAS OCCURRED IN ROUTINE WRITE , FILE INDEX = 0. STATUS = 0

Description

********* NASTRAN FILE TABLE ********* INDEX LOGNAME STREAM_ID NAME 1 SCRATCH 00000001 c:/scratch/assembly.T3284_17.SCRATCH Avoidance: There are 2 possible avoidances. 1. Use the op2 file option. 2. If data recovery is not needed for the external superelements, remove the DMI and DTI entries from the .pch file.

Known Error

CR 1-67273981

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Nonlinear Statics - ANALYSIS=HOT2COLD, scr=no - UFM 1126 (QQGNI) If scr=no is requested along with ANALYSIS=HOT2COLD and rigid elements or MPCs are present the run may terminate with UFM 1126 on data block QQGNI.

Description

Avoidance: Run with scr=yes and insert the following DMAP alter: compile nlstatic alter 1 file qqgni=ovrwrt $ endalter

Known Error

CR 1-67329861

Product

MSC / MD Nastran

Corrected Version Abstract

Perturbation analysis - Output data storing in postprocessing files

Description

In SOL 400 linear perturbation analyses, the solution results from multiple

Known Error

CR 1-67329861 modal analyses are correctly saved in OP2 file. However, the results are not saved in XDB. In MASTER/DBALL, it is found that only the results from the first modal analysis STEP appear to be saved and others seem to get lost. In the case of XDB, Nastran issues the following messages:

*** SYSTEM WARNING MESSAGE 6065 (DBC) *** DBCMSG ERROR MESSAGE 14 FROM SUBROUTINE GRIDBK UNABLE TO OPEN INPUT RELATION EQEXING RETURN CODE = 1. ^^^ USER INFORMATION MESSAGE 9052 (FEA) ^^^ NORMAL MODES ANALYSIS COMPLETED FOR ANALYSIS= MODES Avoidance: Use OP2 for data post-processing. Known Error

CR 1-67375341

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Complex Eigenvalue Analysis - HESS - Inconsistent Results A complex eigenvalue analysis using the Hess method where the mass matrix is many orders of magnitude different that the stiffness matrix may produce inconsistent results. Avoidance: Use the CLAN method as follows: EIGC 104 CLAN +EIGC +EIGC 1.0 0.0 50 50 500

Description

or to run HESS with the following alter: compile ceigrs, list alter 65 matprn ckdxx,cbdxx,cmdxx//'long' $ add ckdxx,/ckdyy/1.e-8 $ add cbdxx,/cbdyy/1.e-8 $ add cmdxx,/cmdyy/1.e-8 $ equivx ckdyy/ckdxx/always$ equivx cbdyy/cbdxx/always$ equivx cmdyy/cmdxx/always$

Known Error

CR 1-67457421

Product

MSC / MD Nastran

Known Error

CR 1-67457421

Corrected Version 2008.0.0 (MD R3) Abstract

Description

Optimization/Design Sensitivity - PBRSECT/PBMSECT may fail in DOM9 a SOL 200 analysis with PBRSECT/PBMSECT entries in the design model may fail in the VKI code with intersecting boundary segments. This failure may occur as the element is designed since the segment may intersect each other as segments becoming thicker. Avoidance: Allow ample space for segments in abitrary beam elements to "grow" without intersecting.

Known Error

CR 1-67610541

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Documentation/QRG - CBAR, CBEAM OFFT field - Incorrect example

Description

The example in the QRG for both the CBEAM and CBAR shows an "O" as the 1st letter for the OFFT field. Remark 8 documents the allowed specifications.

Known Error

CR 1-67661477

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Aeroelastic Analysis - Multiple SPRELAX entries that share relaxed grids give wrong results. If there are multiple SPRELAX entries and the same grids are "relaxed" by two of more of these entries, the job runs but the results are incorrect.

Description Avoidance: Do not attempt to relax the same aerodynamic grid from differing SPRELAX enties. Known Error

CR 1-67677181

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Optimization/Design Sensitivity - PBMSECT, PBRSECT, DOM9 - Inefficient Processing

Description

SOL 200 with a large number of PBMSECT or PBRSECT, arbitrary beam cross section, and design variables may consume a large amount of cpu time in the DOM9 module. The time is spent updating sensitivity for nonlinear relations between design variable and properties.

Known Error

CR 1-67685315

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Documentation/QRG - OPGEOM parameter description incorrect The parameter description for OPGEOM reads, "OPGEOM < *1 prints the set definition for all degrees-of-freedom, including the aerodynamic degrees-offreedom."

Description

This should be:, OPGEOM > -1 prints the set definition for all degrees-of-freedom, including the aerodynamic degrees-of-freedom.

Known Error

CR 1-67685627

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL 400 - tpl test nbolt02b fails with SYSTEM FATAL MESSAGE 2007 (CNTLSTR) The tpl test deck nbolt02b may fail on some platforms with the message:

Description

*** SYSTEM FATAL MESSAGE 2007 (CNTLSTR) ELEMENT 3165 REFERENCES UNDEFINED GRID POINT 0

Known Error

CR 1-67694384

Product

MSC / MD Nastran

Corrected Version Abstract

Superelements - PARAM,DBUP, PARAM,DBDN UFM 1127(GNFIST) Running superelements, using param,dbup and dbdn. On the restart the dbup database is moved to a different diectory or just deleted. The job fails with the following message.

Description

USER FATAL MESSAGE 1127 (GNFIST) DMAP MODULE OUTPRT IS ATTEMPTING TO ACCESS DATA BLOCK 117 NAME = GPECT WHICH IS ON AN UNAVAILABLE DBSET Avoidance: The following alters will correct the problem. In Version 2005.5 - 2006. compile SPDR1 list noref alter 154,154 $alter 158,158 OUTPRT CASES,ECTS,BGPDTS,SILS,XYCDBS,,,,VUPSE,

Known Error

CR 1-67694384 CASEDS,TABEVP,TABEVS,MMCDB,OINT,PELSETS, EDTS/ V01DR0,VSPCG,VMPCG,JUNK,/ S,N,SDRS//'SPARSE'/SPDRRAT/ADPTINDX/ ADPTEXIT $ endalter In version 2007r2 compile SPDR1 list noref $v2007r2 alter 157,157 OUTPRT CASES,ECTS,BGPDTS,SILS,XYCDBS,,,,VUPSE, CASEDS,TABEVP,TABEVS,MMCDB,OINT,PELSETS, EDTS, ,FRFlabel/ V01DR0,VSPCG,VMPCG,JUNK,/ S,N,SDRS//'SPARSE'/SPDRRAT/ADPTINDX/ ADPTEXIT $ The following alter fixes prereleased v2007r3/2008 compile SPDR1 list noref alter 158,158 OUTPRT CASES,ECTS,BGPDTS,SILS,XYCDBS,,,,VUPSE, CASEDS,TABEVP,TABEVS,MMCDB,OINT,PELSETS, EDTS, ,FRFXITZG/ V01DR0,VSPCG,VMPCG,JUNK,/ S,N,SDRS//'SPARSE'/SPDRRAT/ADPTINDX/ ADPTEXIT $ endalter

Known Error

CR 1-67750169

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Description

Elements - STRAIN, CTRIA6 - Null Strain Output If only STRAIN output is requested with PARAM,OMID,YES and CTRIA6 elements are present in the model, the STRAIN results for all the CTRIA6 elements are output as 0.0 when they should be nonzero. With PARAM,OMID,NO (default) the STRAIN results are nonzero. Avoidance: A request of STRESS output will cause the STRAIN results for the TRIA6 elements to be correct.

Known Error

CR 1-67770500

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3)

Known Error

CR 1-67770500

Abstract

SOL 600 - CBEAM - Orientation does not translate properly

Description

SOL 600 does not translate beams whose orientation references other than the basic coordinate system correctly.

Known Error

CR 1-67775400

Product

MSC / MD Nastran

Corrected Version Abstract

SOL 400 - PARAM,POST,0 - All i8 systems, mode=i8, produce SFM 6062 in DBC SOL 400 with mode=i8 and param,post,0 may fail in the DBC module with the following fatal message:

Description

*** SYSTEM FATAL MESSAGE 6062 (DBC) *** DIOMSG ERROR MESSAGE 19 FROM SUBROUTINE BLKFIX OBJECT NQD4R ENTRY LENGTH AND DATA DEFINITION IS INCONSISTENT FOR HETEROGENOUS OPERATIONS. TRANSMIT AND RECEIVE MUST BE USED TO MIGRATE XDB BETWEEN PLATFORMS. 0FATAL ERROR

Known Error

CR 1-67780355

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

SOL 600 - Translation of MAT9 thermal expansion coefficients is incorrect. In SOL 600 the translation of MAT9's thermal expansion coefficients is incorrect. The old and new mapping is as follows:

Description

New Old α11 A1 A1 α12 A4 A2 α13 A6 A3 α22 A2 A4 α23 A5 A5 α33 A3 A6

Known Error

CR 1-67838600

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

External Superelements - EXTSEOUT, MDACMS, and PARAM,FLUIDSE - SFM

Known Error

CR 1-67838600 6144 for MQQ External superelements, EXTSEOUT, combined with mdacms and param,fluidse will lead to the following fatal message: *** SYSTEM FATAL MESSAGE 6144 (MERGE1PR) THE SIZES OF THE INPUT MATRICES AND PARTITIONING VECTORS ARE INCOMPATIBLE. SPECIFICALLY: The number of columns in MQQ is not equal to the number of non-zeros in partitioning vector VFS The number of rows in MQQ is not equal to the number of non-zeros in partitioning vector VFS User Information: Size of input matrices and partitioning vectors: MQQ : Rows= 116 by Cols= 116 VFS : Rows= 2 no. of non-zeros= 1 no. of zeros= 1 Avoidance: Insert the following DMAP alter:

Description

compile mdphs1b alter 'EQUIVX aG',''(,18) alter 'UPARTN USET, PF' EQUIVX aG/aN/nomset $ if ( nomset>-1 ) then $ UPARTN USET,aG/aNBAR,aM,,/LGSET/LNSET//1 $ MPYAD GM,am,aNBAR/aN/1 $ endif $ equivx an/af/nosset $ if ( nosset>-1 ) UPARTN USET,aN/aF,aS,,/LNSET/LFSET//1 $ UPARTN USET, aF/aO,aA1,,/LFSET//LASET/1 $ EQUIVX aA1/aT1/noqset $ alter 'UPARTN USET,PA1' UPARTN USET,aA1/aT1,,,/LASET/LTSET//1 $ alter 'partn po,,vofs' partn bot,vtfs,vofs/bsot,,,bfot/1 $ alter 'partn btt1,vtfs,' partn at1,,vtfs/ast1,aft1,,/1 $ equivx ast1/at1/-1 $ partn ao,,vofs/aso,,,/1 $ alter 'solve kfoo,kfot','' dbstatus kfoo//s,n,nokfoo $ if ( nokfoo>0 ) solve kfoo,kfot,,,/gotf $ alter 'cmpmode'(,-1) if ( methfl>0 ) then $

Known Error

CR 1-67838600 alter 'call cmpmode' ENDIF $ alter 'paraml cmphof','' paraml cmphof//'trai'/1/s,n,nmf//s,n,nocmphof $ if ( nocmphof>-1 ) then $ alter 'merge cmphof,,,gsoqx,' else $ merge ,,gsoqx,,,,vofx/goqq/1 $ endif $ alter 'diagonal cmmif'(,-1) if ( nocmphof>-1 ) then $ alter 'equivx kqqw' endif $ alter 'mpyad at'(,-1) if ( false ) then $ alter 'mpyad aq'(2) endif $ alter 'paraml cmphof'(2) if ( nocmphof>-1 ) then $ alter 'call newlamax'(,-1) else $ merge ,,,,cmphso,,vofx/cmphoxx/1 $ equivx cmphoxx/cmpho/-1 $ merge ,,,,cmphsa,,vafx/cmphaxx/1 $ equivx cmphaxx/cmpha/-1 $ equivx eigvmats/lammat/-1 $ equivx cmmi/mi/-1 $ endif $ alter 'merge ktt,,,kftt,vtfs,' merge at,,,,,vtfs/at2/1 $ equivx at2/at/-1 $ alter 'merge mqtf,,,'(,-1) if ( nocmphof>-1 ) then $ alter 'equivx bqtr\/bqt' else $ merge ,,,mqt,,vtfx,/mqtr/1 $ equivx mqtr/mqt/-1 $ merge ,,,k4qt,,vtfx,/k4qtr/1 $ equivx k4qtr/k4qt/-1 $ merge ,,,bqt,,vtfx,/bqtr/1 $ equivx bqtr/bqt/-1 $

Known Error

CR 1-67838600 endif $ alter 'MERGE ,,PQ,,,,VQ' MERGE ,,aQ,,,,VQ/aQ1/1 $ alter 'UMERGE USET, PQ1, PT' UMERGE USET, aQ1, aT/aA/LASET/'Q' $ alter 'umerge uset,atfs,aqfs','' endalter

Known Error

CR 1-67870768

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

GPFORCE - SET - UWM 2354 (GPFDR), NERROR was set to -98 If a GPFORCE request is made in different subcases where each request specifies a different set, processing may be inefficient of the job may fail with the message:

Description

*** USER WARNING MESSAGE 2354 (GPFDR) MODULE IS UNABLE TO CONTINUE AND HAS BEEN TERMINATED DUE TO ERROR MESSAGE PRINTED ABOVE OR BELOW THIS MESSAGE. THIS ERROR OCCURRED IN CODE WHERE THE VARIABLE -NERROR- WAS SET = -98 *** SYSTEM WARNING MESSAGE 3002 (GPFDR) EOF ENCOUNTERED WHILE READING DATA BLOCK SCRATCH (FILE 314) IN SUBROUTINE GPFDFR

Known Error

CR 1-67922591

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Description

Elements - CBEAM3, PBMSECT using VAM has swapped y/z axes A composite beam defined using the CBEAM3 and PBMSECT entries will swap the y/z axes. Avodiance: if possible, turn the orientation vector for CBEAM3 90 degree in YZ plan.

Known Error

CR 1-68046176

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3)

Known Error

CR 1-68046176

Abstract

Installation - MD Nastran R2.1 does not contain an i8 version for HP MPI

Description

MD Nastran R2.1 does not contain an i8 version for HP MPI. Critical clients have requested this system and it has been added for MD R3.

Known Error

CR 1-68165091

Product

MSC / MD Nastran

Corrected Version Abstract

Chaning analysis - missing temperature results

Description

In SOL 400 chaining analysis while performing a heat transfer followed by a structural analysis, the OP2 file produced by PARAM,POST,-1 will not contain the temperature results.

Avoidance: none Known Error

CR 1-68288009

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Acoustic, Fluid Analysis - CETRA - PFLUID TET4 element Produces Wrong Answer

Description

The lack of a coupled mass matrix for the fluid formulation of the four noded CTETRA element can result in wrong answers and spurious modes. Setting NASTRAN,SYSTEM(446)=1 will result in the old answers.

Known Error

CR 1-68343941

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract Description

Topology Optimization - Stress constrainst lead to Illegal input to DSAH31 A message that indicates illegal input to DSAH31 will be issued in a SOL 200 topology optimization run when stress constraints are included. Avoidance: Remove the stress constraint from the problem definition

Known Error

CR 1-68477767

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Parallel Processing - DMP - DFMFR*: MAXIMUM ESTIMATED FRONT SIZE MAY BE EXCEEDED, Poor Performance

Description

When dmp processing is selected with MDMOES the ordering method must

Known Error

CR 1-68477767 be Extreme (BEND). However, an error in the code may allow METIS to be chosen this may lead to poor performance and the following message: Â *** SYSTEM INFORMATION MESSAGE 6916 (MREORDR) Â Â Â Â DECOMP ORDERING METHOD CHOSEN: DEFAULT, ORDERING METHOD USED: METIS Â DFMFR*: MAXIMUM ESTIMATED FRONT SIZE MAY BE EXCEEDED. Â DFMFR*: MAXIMUM ESTIMATED FRONT SIZE MAY BE EXCEEDED. Â DFMFR*: MAXIMUM ESTIMATED FRONT SIZE MAY BE EXCEEDED. Â DFMFR*: MAXIMUM ESTIMATED FRONT SIZE MAY BE EXCEEDED.

Known Error

CR 1-68554289

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Description

SOL 600 - CHEXA20 - *** error - alias set up on element type 150 which is not on sizing card― SOL 600 may translate the CHEXA20 element incorrectly. The translated alias entry may point to elment type 20 instead of 21. This may lead to the error message: *** error - alias set up on element type 150 which is not on sizing card―

Known Error

CR 1-68655761

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Aeroelastic Analysis - SPLINE7 - Splining nearly coincident points produces bad spline matrix

Description

Splining two coincident points with a SPLINE7 produces good results. However, if one of the points is moved by a very small amount, the resulting spline matrix is bad.

Known Error

CR 1-68672091

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

SOL600 - QRG MATEP - Missing documentation for addrad method

Description

The QRG description of the MATEP "addrad" method was inadvertantly removed from the QRG. The addrad method should be described as: addrad for additive decomposition using the radial return process (SOL 600

Known Error

CR 1-68672091 only)

Known Error

CR 1-68799191

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Optimization/Design Sensitivity - DRESP2, CEIG, LAMA, EiGN, FLUT - Zero Sensitivity

Description

Optimization, SOL 200, with superelements where DRESP2 entries reference a global response via a DRESP1 entry, such as CEIG/LAMA/EIGN/FLUT, may fail due to zero sensitivity on violated constraints.

Known Error

CR 1-68834573

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL 400 - Casi iterative solver hangs in the nlsolv module on Windows

Description

verified with r4 v2009t2 pt400casi.dat run.abb 4/14/09 SOL 400 using the casi solver, see tpl test pt400casi, have been observed to hang in the nlsolv module.

Known Error

CR 1-68928401

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

DMP - PFMODE, PFPANEL, PFGRID - Extra output The modal participation commands PFMODE, PFPANEL, and PFGRID will result in extra output for the slave processes. Avoidance: The following alter can be used to avoid the problem:

Description

compile feafreq $ alter 'call pfact'(1,-1) $ if ( procid0 and nomphvz>-1 ) then $ alter 'mpyad mvv,phivz' merge mphvz,,,,,vvfx/mphvz1/1 $ equivx mphvz1/mphvz/-1 $ Fixed in MDR3 V2008.0.0

Known Error

CR 1-69113343

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

File Management Section - INIT in RC(F) - UFM723(RDINIT) If INIT statement spans two or more lines in RC(F) file, MSC.Nastran 2007r1 and MD R2 will read only the first line and the folloiwng fatal message will be issued: INIT SCRATCH LOGICAL=(SCR1(2000MB),SCR2(2000MB),SCR3(2000MB),

Description

NASTRAN REAL=902037504 $(PROGRAM DEFAULT) *** USER FATAL MESSAGE 723 (RDINIT) LOGICAL= EXPRESSION HAS AN UNBALANCED NUMBER OF PARENTHESES Avoidance: Enter the INIT lines directly in the input deck.

Known Error

CR 1-69161608

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

DMAP - INPUTT4, sparse, ASCII format - terminates without message

Description

When inputting an OUTPUT4 file created using the sparse format (IUNIT0 or','endif \$ not(exterse' endalter

Known Error

CR 1-72269971

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL 144 (DECOMP) - From S. I. M. 3001 in v2005r2/v2005r3 to S. F. M. 3001 in v2007r1

Description

If a modal method is used for static aeroelasticity and the aerodynamic AIC matrix is null, a misleadding SIM will be produced. Setting AESMETH=DIRECT should produce results that indicate the source of the problem.

Known Error

CR 1-72278576

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Nonlinaer Analysis - PCOMP with MEM option fails to converge when using PARAM,COMPMATT Nonlinear Analysis, SOL 106, may fail to converge when temperature dependent material properties for composites using the MEM flag are requested to be updated with each iteration by setting PARAM,COMPMATT,YES.

Description Avoidance: If MD is available, use CQUADR instead of CQUAD4 and run in SOL400. Fixed NQD4D.F & NTR3D.F for temp. dep. composites with MEM option Known Error

CR 1-72288171

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

The NDAMP may not set correctly when NDAMP=-0.05 in SOL 400

Description

For MD R3 and earlier, the following errors exist in NDMAP parameter in SOL 400: 1. The default of NDAMP may not be correct, and 2. If user input NDMAP = -0.05, the NDAMP = 0.0 is used in the analysis. Avoidance: Set NDAMP= -.0500001 or -0.499999if NDAMP = -0.05 is expected.

Known Error

CR 1-72340381

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Acoustics - MECHFIX - Wrong answers or UFM 6144

Description

If masslass mechanisms are detected in a fluid-structure model and the constraint

Known Error

CR 1-72340381 modes are printed with PARAM,MECHPRT,YES will be wrong and the SPCForces will be wrong in versions prior to MDR3. But all other results are unaffected by this error. In MDR3 and V2008, the run will fail with UFM 6144 for matrix MECHG. Avoidance: Insert the following DMAP alter: compile moders alter ' sdr1 '(,-1) dbstatus vafs//s,n,novafs $ if ( novafs>0 ) then $ MERGE mecha,,,,,VAFS/mecha1/1 $ equivx mecha1/mecha/-1 $ endif $ novafs>0

Known Error

CR 1-72340620

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract Description

DMAP - MATGEN option 6 - Wrong answers If P4, P6, or P8 are zero under MATGEN option 6 will produce an incorrect vector. Avoidance: Remove the zero and respecify P3 thru P8.

Known Error

CR 1-72344531

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Description

Licensing - MSC_LICENSE_DISCRETE - Double Feature Checkout, UFM 3060 Setting the variable MSC_LICENSE_DISCRETE is necessary for correct license processing when two license servers, one with concurrent and one with Masterkey or EALU tokens, is used. An error exists in license processing when the MSC_LICENSE_DISCRETE variable is set that may result in a double checkout of the same feature. The error only occurs when the features on the first server are concurrent, i.e. not Masterkey or EALU, and the license check for the feature exists in multiple places in the code. Although all products make use of MSC_LICENSE_DISCRETE, only nastran tends to check for the same feature in multiple locations, so it is much more likely to encounter the problem. A second problem may result in a failed license checkout when a license feature does not exist at all on the first server but does on the second.

Known Error

CR 1-72344531 Avoidance: If unsetting MSC_LICENSE_DISCRETE or pointing to the token based server first is not practical, then the system may be corrected by updating the lapi.so file in the delivery with a corrected version available at: http://www.mscsoftware.com/support/software_updates/lapi.cfm http://www.mscsoftware.com/support/software_updates/. Please note that due to quality 1-72344531, this problem is not resolved on SGI Irix in Verison 2008.

Known Error

CR 1-72382555

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL600 : MARCIN + CELAS problem with MD R2.1

Description

A SOL 600 model with MARCIN and CELAS cards. - The MARCIN is used to write RELEASE BODY in subcase 2 : Nothing is written in the .marc.dat file Note : In fact the MARCIN arguments are well written in the intermediate .marc.dat file (that is first written during the translation), but not on the final .marc.dat. - The CELAS card is used to define a dummy spring for stabilization or a rigid body during subcase 2 : The spring partially defined in the .marc.dat file which cause exit 13. Only the 2nd data block of the SPRINGS card is written (1st and 3rd are missing)

Known Error

CR 1-72393724

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

Force on a rigid body Error (original): For SOL700 MD R3,a dynamic loading (TLOADi) applied to a rigid body will result in the following error. *** USER FATAL MESSAGE 313 (IFPDRV) ILLEGAL NUMBER OF WORDS ON BULK DATA ENTRY MOMENT 1007 SORTED ENTRY COUNT = 44 USER INFORMATION: THIS MESSAGE IS USUALLY ISSUED WHEN THERE ARE ERRORS ON THE CONTINUATIONS ENTRIES. 1- FIELD 1 IS NOT UNIQUE OR IS BLANK 2- FIELD 10 ON ONE OR MORE ENTRIES IS THE SAME AS FIELD 1 ON THIS ENTRY fixed in 2010

Known Error

CR 1-72420191

Known Error

CR 1-72420191

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Database - PARAM,DBALL,MASTER and DBSETDEL DBALL - UFM 1124 If PARAM,DBALL,MASTER is specified along with DBSETDEL DBALL then the run will fail with UFM 1124. Avoidance: Insert the following DMAP alter:

Description compile ifpl alter 1 type parm,nddl,char8,n,ifpx $ ifpx='master' $ endalter Known Error

CR 1-72492073

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

An AESO run with ANALSYSIS=MTRAN fails with SFM 3001 in DSAR In v2007 (MD R2), when an AESO run includes a modal transient subcase, it fails with the following error message:

Description

^^^ ^^^ USER INFORMATION MESSAGE 9181 (FEA) ^^^ THE JOB IS TERMINATED FOR AN AUTO EXTERNAL CREATION RUN ^^^ *** SYSTEM FATAL MESSAGE 3001 (DSAR) THE INPUT DATA BLOCK NAMED TOL AT POSITION 2 DOES NOT EXIST. USER INFORMATION: THIS ERROR IS CAUSED BY ONE OF THE FOLLOWING: 1. THE DATA BLOCK WAS NEVER CREATED. 2. THE DATA BLOCK WAS DELETED. 3. THE DATA BLOCK IS SPECIFIED ON A TYPE STATEMENT IN THE CURRENT SUBDMAP OR A HIGHER SUBDMAP BUT THE CURRENT QUALIFIER VALUES DO NOT MATCH THE QUALIFIER VALUES OF THE DATA BLOCK(S) ON THE DATABASE. USER ACTION: 1. IF YOU ARE EXECUTING AN MSC.SOFTWARE SUPPLIED SOLUTION SEQUENCE AND NOT USING THE ALTER EXECUTIVE CONTROL STATEMENT, THEN CHECK FOR BULK DATA AND/OR CASE CONTROL INPUT ERRORS. IF NO ERRORS CAN BE FOUND, THEN CONTACT MSC.SOFTWARE CLIENT SUPPORT. 2. IF YOU ARE EXECUTING A DMAP PROGRAM NOT SUPPLIED BY MSC.SOFTWARE, THEN FOR DEBUGGING PURPOSES INSERT STATEMENT DIAGON(20) BEFORE THE MODULE SHOWN

Known Error

CR 1-72492073 ABOVE. PROGRAMMER INFORMATION: THE FIST NUMBER IS 102 AND SUBROUTINE IS DSAR 0FATAL ERROR Avoidance: No avoidance exist. Corrected in 2010.

Known Error

CR 1-72560731

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

MATD015 is not working properly

Description

The MATD015 description in the QRG has been updated and the coding within dytran-lsdyna has been updated for the MD 2010 release. MATD015 should not be used in the MDR3 or earlier releases.

Known Error

CR 1-72578767

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Invalid input on PBUSHT does not issue message, but gives zero results

Description

On the PBUSHT entry, to activate the "fuse" functionality, the LOWER fuse value must be less than the UPPER fuse value. However, entering them in the wrong order (such that UPPER is less that LOWER) does not generate a warning or fatal message. Instead, the CBUSH elements pick up zero load.

Known Error

CR 1-72589921

Product

MSC / MD Nastran

Corrected Version GL Abstract

Licensing - Lapi, Discrete - SGI Irix will not work with Lapi 7.3.0 and above

Description

MD Nastran R3 on SGI Irix has reached the operating system limit of the dso table size and this prevents upgrading the Lapi FLEXlm licensing layer to 7.3 or above. Until this is resolved the DISCRETE double check out problem, quality 1-72344531, can not be addressed on this platform.

Known Error

CR 1-72664491

Product

MSC / MD Nastran

Corrected Version Abstract

Symbolic Substitution - % in comment leads to invalid subst message in log

Description

A comment in the Bulk Data section that contains a % character will produce

Known Error

CR 1-72664491 a benign message in the symbolic substitution report. For example, $ Test the command %unsetrewidth produces the following message: Symbolic substitution request starting at column 9 invalid. Syntax error found at column 23 The message does not clearly indicate the problem. Note that this has no impact on the run. Avoidance: None.

Known Error

CR 1-72804117

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Documentation/QRG - SOL 700, BCTABLE - Error in QRG entry for BCTABLE, METHOD field

Description

The MD 2.1 QRG that is delivered with the software installation has two items transposed in the description of the METHOD field on the BCTABLE entry. It currently appears as follows: "SS1WAY: Surface to Surface Two Way" and "SS2WAY: Surface to Surface One Way." It should be switched so that SS1WAY indicates one-way contact and SS2WAY indicates two-way contact.

Known Error

CR 1-72906331

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

In SOL 600, MAT8 and MAT9 may only have 6 digits. Digits beyond 6 are truncated MAT8 and MAT9 may only have 6 digits in SOL 600, digits beyond 6 are truncated. Fixed in 2010

Known Error

CR 1-72916101

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SPLINEx entry does not support displacement coordinate system(s) on GRID entries

Description

If a structural or aerodynamic GRID entry has a displacement coordinate

Known Error

CR 1-72916101 system(field 7), the spline matrix for SPLINx entries will be incorrect. Avodiance: None.

Known Error

CR 1-72962981

Product

MSC / MD Nastran

Corrected Version 2007.0.1 Abstract

Aeroelastic Analysis - PAERO1 - SFM 3007 Illegal input to subroutine APD12

Description

The above message will be issued if the user inadvertently places an integer in fields 4 thru 8 of a PAERO1 entry when a preceding field has been left blank. Avoidance:Correct the paero1 entry.

Known Error

CR 1-72963956

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

BAROR OFFT "B" causes error When the BAROR bulk data entry is used to specify the CBAR bulk data entry defaults for the offset vectors and the OFFT field contains the "BGG" string, Nastran generates a fatal error indicating that there is a format and/or data error for the CBAR bulk data entries. This behavior has been noticed starting with the MSC 2007.0.1 version. Avoidance: Place the offsets directly on the CBAR bulk data entries.

Known Error

CR 1-72965609

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Initial time step is for SOL 600 is not always obtained from TSTEPNL

Description

The initial time step is not the desired value for the attached model because the default for the initial time step is to use the smaller of DT from TSTEPNL or 1/100.0 of the first non-zero time on the TLOAD1 curve. A new option triggered by PARAM,MARAUTOC,1 has been added to override these defaults and use the initial time step from NLAUTO even when it is larger than the default DT.

Known Error

CR 1-73000881

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Documentation/QRG - NLADAPT SOL 400 - Incorrect field definition

Known Error

CR 1-73000881

Description

The QRG description of the NLAPAPT entry incorrectly references a DMAP field in addition to the correct field description which is IDAMP. This reference should be removed.

Known Error

CR 1-73001379

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

SOL 700, Significant stress/strain oscillations present during rotation (constant load) simulation. Error: For some models, significant stress/strain oscillations are present during a constant load explicit simulation when implicit-explicit switching is used. The stress oscillations are not consistent with the constant load boundary conditions & initial conditions and are significantly higher than those experienced in a comparable MSC.Dytran simulation. The stress/strain variations are significant enough to affect the solution of an impact simulation. fixed in 2010

Known Error

CR 1-73001428

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL 700 - Errors with initial stress (ISTRSSH) output created from implicit (PRESTRS) simulation. WAS: Problem was solved by LSTC developer. Model had some input issues. (6/11/09) Casey/Walter, As Lee told, the problems are solved, I think. The run takes around half day and then I can’t make summary now. I will make summary and distribute the results tomorrow.

Description

The stress oscillation is almost zero. We also need to tell our AE’s about the modeling because there are many errors in the modeling. I updated the items below to the original model. 1. Boundary conditions 2. Drill Projection

Known Error

CR 1-73001428 3. Shell formulation for the same as the implicit run. 4. Initial rotating velocity 5. Bulk modulus The most important items are boundary condition and drill projection. 1. For rotating blades, the drill projection for shell elements must be set to “Full Projection.― 2. Boundary_Prescribed_motion card of LS-DYNA (SPCD2 card of MD Nastran) If the dof of boundary prescribed motion card in ls-dyna is not set, the dof is free (?). For example, the blade base also rotates at y-axis with gap from the rotation center. Then, the DOF of SPCD2 card must be set to 10 (z/x degrees-of-freedom for node rotating about the y-axis at location (OFFSET1,OFFSET2) in the zxplane, point (z,x). Radial motion is NOT permitted. Not applicable to rigid bodies) However, 6 (y-rotational degree-of-freedom) of DOF also needs additionally. Because 10 can make the rotation of points but, the points are fixed on y-axis rotation. +++++ When running a prestress (PRESTRS) simulation with composite shell elements the resultant initial stress information (ISTRSSH) written to the .nastin file has errors. See below for details. Some of the items in the ISTRSSH option are known to be wrong based upon the LS-Dyna documentation, however some options are not documented so the status is not known. However, it is known that using the default .nastin file on a rotating composite shell simulation causes it to diverge early in the simulation while removing the ISTRSSH history variables allows the simulation to complete. Notes on results: • Significant stress/strain oscillations are present in both cases (reference CR ). However, these oscillations worse for the case that includes the default .nastin file • Negative “internal energy― is indicated in the .d3hsp files for both cases, (again this is significantly worse for the case that includes the default .nastin file)

Known Error

CR 1-73001428 • Negative “strain energy density― is visible in some elements for both cases; using Patran to post process results (.d3plot files). (again this is significantly worse for the case that includes the default .nastin file)

Known Error

CR 1-73052213

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

SOL 700 - RFORCE requires grid (G) reference for rotation axis (requirement is not documented) RFORCE (angular velocity/acceleration load) has an optional grid (G) entry to define the center of rotation. In SOL 700 if the grid (G) entry is not entered on the RFORCE a fatal message occurs in the .dytr_prep.out file. This grid option is not required in standard MSC/MD Nastran solution sequences but is required in SOL 700; however this requirement is not documented.

Avoidance: Create a grid at the center of rotation and reference this grid on the RFORCE entry. Known Error

CR 1-73066637

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL 700 requires SPC entries

Description

MD SOL 700 simulation with grounded springs (CELAS) and grids with permanent constraints. Solution fails with the following errors: - error in .log file: forrtl: severe (36): attempt to access non-existent record, unit 91, file C:\data\0-Hamilton_MD_SOL700\CR_-MD_SOL700-106_to_700\spcprm.3dc Avoidance: Create at least 1 SPC (SPC, SPC1, …) Bulk Data entry within MD Nastran input file and reference this from the case control section (SPC=#).

Known Error

CR 1-73140831

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

An FBA run with a DAREA entry for a non-existent point fails with an unhelpful SFM 7540 in GP1

Known Error

Description

CR 1-73140831 An FBA run with a DAREA entry for a non-existent point fails with a very confusing and unhelpful SFM 7540 in the GP1 module. The program should issue a UWM, ignore all DAREA entries (since these entries are not meaningful in FBA runs) and proceed normally with the execution. Avoidance: Remove DAREA entries that reference a non-existent GRID.

Known Error

CR 1-73228870

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Buckling or Preload - STATSUB, REPCASE - SFE 4276 in EMG If STATSUB references a static subcase which appears below a REPCASE then the job will terminate in EMG with SFE 4276.

Description

Avoidance: Re-arrange the subcases so that the subcase referenced by STATSUB appears above REPCASE.

Known Error

CR 1-73336021

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

DMAP - MATGEN option 6 - SFE 4276 If any of the parameters P3, P5, P7, or P9 are negative with MATGEN option 6 (P1=6) then the run may terminate in a later module that uses the MATGEN output. If P2, P4, P6, or P8 are set to a negative number, then the run will assume zero and this should not be allowed because the zero assumption may not apply to all platforms. Avoidance: No avoidance exists.

Known Error

CR 1-73346749

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

The friction force outputs is incorrect for ANALYSIS=NLTRAN in 3D Contact in SOL 400 In MDr3 and earlier, the friction force outputs is incorrect for ANALYSIS=NLSTRAN in 3D Contact analysis in SOL 400. Note that this error only affect the friction force outputs but not the force itself.

Known Error

CR 1-73346749 Avoidance: No avoidance available.

Known Error

CR 1-73356415

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Reduction - PARAMs INREL or FIXEDB - Wrong answers or UFM 6144 or UFM 9050 If PARAMs INREL or FIXEDB are specified in the second or greater subcases with non-default values but not in the first subcase then they will be ignored during the stiffness and mass reduction to the l-set--computing KLL, MLL, etc. resulting in fatal errors or wrong answers. The error occurs in SOL 200 and in SOL 101 with scr=no. See also related CR 1-57703594.

Description Avoidance: Insert the following DMAP alter: compile phase1dr alter 'PVT PVTS,'(3),'' endalter Known Error

CR 1-73371791

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

SOL 700 - PBEAM with tapered cross section translated as constant cross section, Wrong Answers In SOL 700, the PBEAM elements referencing a varying (tapered) cross section is not translated correctly. The tapered PBEAM is translated to SOL 700 as a constant cross section beam (based on the first cross section entered) and no warning message is indicated to inform the user that the tapered beam is not being translated. Avoidance: Since a tapered cross section is not supported in the dytranlsdyna solver, the only avoidance is to input an average constant cross section. MD R4 will be enhanced to automatically calculate the average cross section.

Known Error

CR 1-73386147

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

1d to 3d contact issues UFM 3001 M3DCONT1, BGPDT

Description

If there are no BCBODY/BSURF bulk data entries that correspond to the

Known Error

CR 1-73386147 SLAVE IDs of the BCTABLE entry, M3DCONT1 issues UFM 3001 for a missing BGPDT table. Avoidance: none known. Fixed in 2010

Known Error

CR 1-73429260

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

SOL 400 - View factor computation failed to converged using the Hemi-cube method The SOL 400 view factor calculation may fail to converge using the hemicube method. Avoidance: Do no select the hemi-cube method on the NLMOPTS entry.

Known Error

CR 1-73545872

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL 400 - RFORCE - SFM 5423 (MPYAD), Incompatible Matrix Multiple

Description

When there is RFORCE type follower force, SOL 400 may fail in MPYAD with SYSTEM FATAL MESSAGE 5423 indicating an incompatible matrix multiple when the model also has either 3D Cotnact or nonlinear RBE elements. Avoidance: There is no practical avoidance except to turn off follower forces by setting LGDISP=-1.

Known Error

CR 1-73549211

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

UFM 608 for MODALSE SET Request, 2007 fails, 2005r3b works The following MODALSE command may fail in 2007 with UFM 608 MODALSE(SORT1,PRINT,freq=201,thresh=1.-30)=100

Description

*** USER FATAL MESSAGE 608 (IFP1D) THE SET ID SPECIFIED ON THE ABOVE CARD MUST BE DEFINED PRIOR TO THIS CARD.

Known Error

CR 1-73626721

Product

MSC / MD Nastran

Corrected Version 2008.0.1 Abstract

Parallel Processing - PARALLEL, SYSTEM(107) - Vendor implementation of subroutine TFORK is missing Shared memory parallel processing does not work on Windows 32 MD R3 Nastran (Version 2008.0.0). If attempted (setting parallel (system(107) keyword on the nastran or submittal line) the job will fail with the message:

Description system fatal: Vendor implementation of subroutine TFORK is missing Avoidance: The MD R3 delivery will be corrected with Version 2008.0.1. Known Error

CR 1-73726361

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Documentation/IOG - Get garbled of MD Nastran R3 Installation and Operations Guide Page 61 and 169 of the MD R3 IOG have mangled text.

Description

Avoidance: The mangled text is not significant to the understanding of the section. No avoidance is necessary The first The text is not t

Known Error

CR 1-73741883

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Trap errors unaccpetable values for fields METHOD, RACC, & MB in the RFORCE card for SOL 700 Error: For MD SOL700 R3, METHOD, RACC, & MB in the RFORCE card are not acceptable without any error message.

Description

For 2010: Fixed: QRG was updated in REMARK of RFORCE. "19. Fields METHOD, RACC, MB and IDRF will be ignored for MD Nastran SOL 700." In addition, warning message was added in SOL700. "MEHTOD/RACC/MD/IDRF will be ignored."

Known Error

CR 1-73747346

Product

MSC / MD Nastran

Known Error

CR 1-73747346

Corrected Version 2010.1.0 (MD R4) Abstract

External Superelements and Acoustic Analysis - UFM 6962 in MATGEN or UFM 6144 in PARTN In a fluid-structure model, if the c-set only contains fluid degrees-of-freedom then the run will fail with UFM 6962 or 6144. Avoidance: Insert the following DMAP alter.

Description

compile mhred alter '\/got\/','' upartn uset,vgfs/vft,,,/'g'/'t'//1 $ merge got1,,,gotf,vft,vfo/got/1 $ compile semr4 alter 'if ( mhred','' upartn uset,vgfs/vrcf,,,/'g'/'r+c'//1 $ paraml vrcf//'null'//s,n,fullvrcf//s,n,nullvrcf $ if ( mhred='yes' and fullvrcf=1 ) norc1=-1 $ alter 'if ( mhred'(2) norc=norc1 $

Known Error

CR 1-73810003

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Imporve SOL 600 dynamics loads for multiple subcases

Description

For some models with multiple subcases for dyamics and complex loading the loads are not correct. Change to Marc's "Total Loads" as they appear to be more correct than incremental loads for multiple subcases.

Known Error

CR 1-73816550

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Documentation/QRG - PBRSECT - Composites are not supported

Description

The QRG documentation for the PBRSECT entry incorrectly indicates that it supports composites and can reference Core and/or Layer. This capability is only supported with PBMSECT and if attempted with PBRSECT will lead to an error in IFP indicating illegal format.

Known Error

CR 1-73873851

Product

MSC / MD Nastran

Corrected Version 2008.0.1 Abstract

Miscellaneous - f04 file missing delta cpu information

Known Error

CR 1-73873851

Description

The MD R3 Verson 2008.0.0 f04 file (Execution Summary) on Windows 32 indicates 0.0 for DEL I/0, CPU and DEL CPU. The MD R3 delivery will be corrected in 2008.0.1.

Known Error

CR 1-73880221

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL 400 - tpl test nlsqa468 fails wit ufm 9196, A REQUEST IS MADE TO CHAIN WITH NLIC tpl test nlsqa468 fails wit the message:

Description

USER FATAL MESSAT 9196 A REQUEST IS MADE TO CHAIN FROM NLIC FROM STEP NLIC TO STEP NLIC.

Known Error

CR 1-73921221

Product

MSC / MD Nastran

Corrected 2010.1.0 (MD R4) Version Abstract

Optimization/Design Sensitivity - Enforced Motion - SFM 5423 (MPYAD) SOL 200 with enforced motion may fail in mpyad with the following error:

*** SYSTEM FATAL MESSAGE 5423 (MPYAD1) ATTEMPT TO MULTIPLY INCOMPATIBLE MATRICES FILE# COLS ROWS FORM TYPE NZWD DENS TRAILER FOR RPH1 IS 101 86 276780 2 2553560 10000 TRAILER FOR UHF1 IS 102 7 86 2 4 344 10000 TRAILER FOR YPO1 IS 103 7 276794 Descriptio 2 4****** 10000 n TRANSPOSE FLAG IS 0

Avoidance: Apply the following dmap compile disopts alter 'call fea'(2),'' CALL FEA, $..Input Data Blocks: abe,acpt,,aebgpdts,aecomp,aero,aeusets, , ,bgpdtvu, ,CASECC, caseds,casem,CASERS,CASES,casesx, ,control,cstma,CSTMS, ,

Known Error

CR 1-73921221 DEQATN,DEQIND, ,DIT,dits,DMIs,DMINDXs,drg, , DYNAMIC,DYNAMICS,ectas, ,EDT,eht, ehta,elemvol,EMAP,EPT,epta,EPTS,eqexin,EQEXINS,ETT,extdb,,,FORCE, gdgk0,gdksk,gdntab,GEOM1,geom1qx,geom1s,GEOM2,GEOM2S,GEOM3,GEOM3S, GEOM4,GEOM4S, ,gpgk0,gpksk,GPLS,gpsnts,,INDTA, ,MAPS, matpool,matpools,medge,mklist,mmcdb,MPT,MPTS, ,oint,PCDB,PCDBS, pcompts,pelsets,,POSTCDB, ,pval,PVT,pvtbc,PVTS, , ,scstm, SILS,SLIST,SLT,spline,SPSEL,tabdeq,tabevp,tabevs, ,trx,,,,,VGFS, ,viewtb,XYCDB,XYCDBS,yg,mpjn2o,mpjsfn2o,aempcomp,aemonpt, saemprk,strucomp,monitor,saerg0,aedbstdx,uxvst,pgvst0,,,,,,xsop2dir, CASEDM,LVTABI,geom1qs,geom4qs,selist,pvt0, dmonpta,dmonpts,sdsrg0,sdark,pvperq,dtis,dtindxs,pbrmsd,pbrms, mp1,mpd1,mp3,strplab, edts,ymu,,,,,ifexpnt,vefs,afpmlist,, pjvndx,pjvndxs,/ $..Output Data Blocks: , , , , ,AQG,AUA,AUG, , B2DD,B2MG,B2SF, ,bdict,belm, ,BGPDTS,bgpdt,BHH, , ,BLAMA, BLAMA1,BMG,BPHA,BSF,BUG, ,CB2DD, , CK2DD,clama,CMDD,CMLAMA,CMPHA,CMPHO,cphd,cphh,cphp, crj,crx, , , , ,Dar, , ,DFFDNF, ditid, ,dlt,ECTS,, , ,EST, ,FLAMA, ,FOL,FOL1,FPHH,frl, , , , , ,GM,GOQ,GOT, ,GPECT, , , , K2DD,k2mg, ,K2SF, , , , ,K4MG,K4SF, , , , ,KDICT, ,KELM, KFS,KHH, , ,KMG,KSF,KSS, , , ,LAMA,LAMA1,LAMAF,LAMAS,LLL, , lphd,lphh,lphp, , , M2MG,M2SF,MAR, ,MDICT,MEA,MELM,MHH, , ,mjj, , ,MMG, , ,MSF,MTRAK, , , ,PDF,PDT,PDTDS,PG, ,PHA, ,PHDH,PHF, PHFA, ,PHG, , , , , ,PHQG,PHSA,PJ, , ,PNLH,PPF,PPF1,PPT,PPTDS,PP1DS,PSF,PSF1,PSS,PST, ,PSTDS,PTELEM,QG, , , , , , , , , ,qmg,qmpf,qmpt,QPF,QPT,QR, , , ,TOL,TOL1,TOL2,TR, , , ,UDF,UG, ,,UHF,UHT,UHTDS,UL, ULF, ,ULTDS,UOO,UPF,UPT, , ,USET,USETD, VAFS,VELEM, ,vgfd,VPHFS,WKK, , , ,YS, , , ,,,,,,,,,,,,,,,,,,mdphiq,mdgot,mdgoq,mdvft,mdmap, mdgrdrm,mp2slab,mp2st,mp2ugcp,mp3int,mp3lab,mp3gpf, mp2a,mp3a,mp2sa,mp3sa,s2a,s3a,sdsa,,,,thetam, aciect,sild / $..Input Parameters: AERO/adjflg/AERTYP/ALTRED/APP/AUNITS/AUTOSPC/BUCKCC/cnvflg/true/ CYCLIC/dceigcc/DESCYCLE/deseig/desmax/DFRQCC/DFRQDSA/dfrspcf/DMRESD/ DROPT/DROPTDS/dstspcf/DVRGCC/dtrspcf/ebis/ERROR/EXTERSE/FEAOPT/

Known Error

CR 1-73921221 FIXEDB/fluidse0/FLUTCC/FSCOUP/G/GUSTAERO/HFREQ/IKBAR/IMACHNO/INREL/ IQ/KDAMP/enfmeth/LASTSEID/LFREQ/LMODES/LUSETS/mceigcc/MFRQCC/ MFRQDSA/MODACC/MODECC/MTRNDSA/MTRNCC/NASOUT/nk/NLHEAT/NOPH1/N OPH2/ NOSEDV/OPTIMIZE/PEXIST/PSLOAD/rgsens/RSONLY/SAERCC/SAERODSA/SEKR/ SELG/SELR/SEMG/SEMR/SKPAMG/SKPAMP/SOLTYP/STATCC/STATDSA/false/ $..I/O Parameters: S,ADPTEXIT/S,ADPTINDX/s,BOV/s,BMETH/s,CARDNO/s,freqdep/ s,FS/s,luset/s,METHF/s,MDTRKFLG/s,MODETRAK/s,NMSOL/s,NORSET/ s,NOSASET/s,NSOL/s,PFILE/S,PVALID/s,STATSUB/s,SUPORT/0/0.0 $ compile cforce1 alter 'PARTN MXY,VYFS'(,-1) paraml vyfs//'null'////s,n,nullvyfs $ if ( nullvyfs=-1 ) then $ CALL RSDAMP CASES,DYNAMICS,DIT,MXY,KXY,K4XY, ,,,,,,,/ BXYPD,K4XYPD/ APP/'DIRECT'/FALSE/FALSE/FALSE/ S,NOBPD/S,NOK4PD $ if ( dynspcf='new' or mpcforce ) CALL RSDAMP, CASES,DYNAMICS,DIT,MQXY,,K4QXY, ,,,,,,,/ BQXYPD,K4QXYPD/ APP/'DIRECT'/FALSE/FALSE/FALSE/ S,NOBPD/S,NOK4PD $ else $ alter 'MERGE K4SQXYPD,'(,1) endif $

Known Error

CR 1-73942581

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Using PVA in CONV field of NLPARM in SOL 101 gives SYNTAX FATAL If PVA is entered in the CONV field of an NLPARM entry, SOL 101 will fail with a FATAL error.

Description

Avoidance: Change or remove the NLPARM entry.

Known Error

CR 1-73960321

Product

MSC / MD Nastran

Known Error

CR 1-73960321

Corrected Version 2010.1.0 (MD R4) Abstract

Exterior Superelements - EXTSEOUT with ACMS - Inefficient Processing SOL 103 with EXTSEOUT and ACMS could perform unneeded operations under the following conditions: 1. No data recovery is specified. 2. A sparse data recovery request is made, and the grid points in the data recovery request all reside in the A-set.

Description

In either of the two above cases, the program reacts as if FULL data recovery has been requested. This results in significant unnecessary operations taking place. Avoidnace: Workaround is to use the following DMAP alter: compile mdphs1b alter 'bdryinfo' $ dbstatus caseo//s,n,nocaseo $ if (nocaseo = -1) equivx cases/caseo/-1 $ endalter For one user model, this change resulted in a 33% decrease in runtime (from 412 minutes to 274 minutes).

Known Error

CR 1-74029506

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

External Superelements - SOL 200 - SFM 1222 (LDRTRN) or SFM 6551 (INPTX2)

Description

A SOL 200 run with external SE run and scr=no will fail in V2007 and V2008 with one of the following messages in subdmap EXTOTMIN on an INPUTT2 statement. ============ *** USER INFORMATION MESSAGE 7321 (SEDRDR) DATA RECOVERY FOR SUPERELEMENT 60 IS NOW INITIATED. *** SYSTEM FATAL MESSAGE 1222 (LDRTRN) AN UNEXPECTED END OF FILE WAS DETECTED ON A NEUTRAL FILE DURING A DBLOAD OPERATION USER INFORMATION: THIS ERROR TERMINATES PROGRAM EXECUTION AND GENERALLY OCCURS WHEN THE DBUNLOAD JOB FAILS DURING NEUTRAL FILE CREATION

Known Error

CR 1-74029506 USER ACTION: REVIEW NEUTRAL FILE CREATION JOB FOR FATAL MESSAGES 0FATAL ERROR ============= *** USER INFORMATION MESSAGE 7321 (SEDRDR) DATA RECOVERY FOR SUPERELEMENT 10 IS NOW INITIATED. *** SYSTEM FATAL MESSAGE 6551 (INPTX2) AN END-OF-FILE WAS DETECTED ON UNIT 31 DURING BINARY INPUTT2 PROCESSING PROGRAMMER INFORMATION: 1. A KEY VALUE WAS BEING READ 2. THE LAST KEY VALUE READ: 0 0*** FATAL ERROR. 0 NO. FORTRAN RECORDS READ = 0 NO. FORTRAN WORDS READ = 0 =================== Avoidance: insert the following DMAP alter: compile super3 alter 'call extin','' call extin ,,,,,,xsop2dir,extdb,,,/ ,,,,,,,,,/ seid/setype/lusets/false/s,np $

Known Error

CR 1-74077245

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Optimization/Design Sensitivity - PART SE and missing inlcude file does exit UFM 398 A SOL 200 run with PART superelements and missing include files will issue a fatal message but continue to process.

Description

*** USER FATAL MESSAGE 398 (GETLIN) A REQUESTED INCLUDE FILE WAS NOT FOUND. FILE 'missingfile.dat'

Known Error

CR 1-74123421

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Frequency Response - frequency-dependent elements, CBUSH, enforced motion, acoustics - SFM 6144

Description

In SOL 111 with frequency-dependent elements, enforced motion, and acoustics the following message may be issued

Known Error

CR 1-74123421 *** SYSTEM FATAL MESSAGE 6144 (PARTN1PR) THE SIZES OF THE INPUT MATRICES AND PARTITIONING VECTORS ARE INCOMPATIBLE. SPECIFICALLY: The number of columns in KFDSH is not equal to the number of rows in the column partitioning vector VYFS User Information: Size of input matrix and partitioning vectors: KFDSH : Rows= 12 by Cols= 5080 VYFS : Rows= 6571022 VXFS : Rows= 12 Avoidance: Insert following DMAP alter: compile freqrs alter 'call cforce','' call CFORCE USETd,,ysti,,,,Bfdsh,,kfdsh,k4fdsh, ,,,foli,,,cases,dynamics,dit,vgfs,vphfs,nzyg/ pyfdi/ APP/APP/'enforce'/true/false/fs/fonly $ endalter

Known Error

CR 1-74141249

Product

MSC / MD Nastran

Corrected Version 2008.0.1 Abstract

Description

Licensing - MD R3 Windows 32, Linux x8664, prog= - UFM 3060 (SCA Service Loader) The MD R3 (2008.0.0) Windows 32 and Linux x8664 SCA enabled builds can not be used with vertical application licensing such as SimXpert or SimDesigner unless a full MD Nastran License also exists. If attempted the run will fail with the message: *** USER FATAL MESSAGE 3060 (SCA Service Loader) - AUTHORIZATION ERROR *** UNABLE TO OBTAIN LICENSES FOR SCA.MDSolver.System.PrintServer PLEASE REFER TO THE LOG FILE FOR ADDITIONAL DETAILS

Known Error

CR 1-74160738

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Documentation/QRG - NASTRAN SYSTEM(206)

Description

The NASTRAN SYSTEM(206) QRG documentation is slightly out of date. It currently reads:

Known Error

CR 1-74160738 0 Method selected automatically in symbolic factoring phase (Default for NEC). 4 Extreme ordering. 8 METIS ordering. Metis was developed by George Karpis and Vipin Kumar at the University of Minnesota. More information may be found at http://www.cs.umn.edu/~karypis/metis (Default for all other machines). Should be: 0 Method selected automatically in symbolic factoring phase (Default) 4 Extreme ordering (BEND). 8 METIS ordering. Metis was developed by George Karpis and Vipin Kumar at the University of Minnesota. More information may be found at http://www.cs.umn.edu/~karypis/metis

Known Error

CR 1-74160923

Product

MSC / MD Nastran

Corrected Version Abstract

Output heading sequence seems incorrect In SOL 400 liear perturbation analysis, the output labels look in disorder. For example: Output heading sequence seems to go from STEP 5 to STEP 1 within a subcase. mug_39b.dat was used for this run.

Description

1 BRAKE SQUEAL COMPLEX MODES JUNE 11, 2008 MD NASTRAN 5/ 8/08 PAGE 50 MD NASTRAN ADVANCED NONLINEAR SOLUTION PATH 0 BRAKE SQUEAL MODES AT 100% PISTON LOAD 0.3 FRICTION COEFF SUBCASE 100 STEP 5 ^^^ USER INFORMATION MESSAGE 9051 (FEA) ^^^ MODAL COMPLEX EIGENVALUE ANALYSIS - DATA RECOVERY COMPLETED. DESIGN CYCLE NUMBER= 1 1 BRAKE SQUEAL COMPLEX MODES JUNE 11, 2008 MD NASTRAN 5/ 8/08 PAGE 51 MD NASTRAN ADVANCED NONLINEAR SOLUTION PATH 0 BRAKE SQUEAL MODES AT 100% PISTON LOAD 0.3 FRICTION COEFF SUBCASE 100 STEP 5 1 BRAKE SQUEAL COMPLEX MODES JUNE 11, 2008 MD NASTRAN 5/ 8/08 PAGE 52

Known Error

CR 1-74160923 MD NASTRAN ADVANCED NONLINEAR SOLUTION PATH 0 NONLINEAR STATIC STEP SUBCASE 100 STEP 1 *** USER INFORMATION MESSAGE 8101 (NL3INT) The Lagrange Multiplier Factor and Penalty Function values: LMFACT=2.450417E+07 and PENFN=2.450417E+07 flexible body # 1 (body_4 ) will detect flexible body # 2 (body_5 ) flexible body # 1 (body_4 ) will detect flexible body # 3 (body_6 ) *** USER INFORMATION MESSAGE 6204 (NL3EMA) 1.515527E+01 SECONDS REQUIRED TO DECOMPOSE MATRIX. This is because Nastran must rerun STEP 1 at user-specified loadfactor to re-compute nonlinear stiffness matrix for STEP 5 linear perturbation analysis. No avoidance available.

Known Error

CR 1-74178201

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Documentation/QRG - SMEM - Incorrect Example The example for SMEM under the SMEMORY description in the QRG is incorrect.

Description

ASSIGN SCRATCH(MEM=value) should be changed to INIT SCRATCH(MEM=value)

Known Error

CR 1-74181990

Product

MSC / MD Nastran

Corrected Version Abstract

A shape opt job with designed grids connecting only RBEi elements fails with UFM300 in DSAE

Description

When a shape optimization job only designs the grid points that only connect to RBEi elements, it fails with the following error message:

Known Error

CR 1-74181990 *** SYSTEM FATAL MESSAGE 3003 (DSAE) ATTEMPT TO READ PAST THE END OF A LOGICAL RECORD IN DATA BLOCK TABEVS (FILE 104) IN SUBROUTINE DSAE Avoidance: None

Known Error

CR 1-74197533

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SMETHOD=ELEMENT fails when inside STEP SOL 400 in MDR3 with SMETHOD=ELEMENT case control command within a STEP

Description

resulted in the following confusing message: *** USER FATAL MESSAGE 604 (IFP1D) THE ABOVE CARD HAS A NON-INTEGER IN AN INTEGER FIELD.

Known Error

CR 1-74205731

Product

MSC / MD Nastran

Corrected Version GL Abstract

Performance - Windows Vista 64, Server 2008 Vista 64 and Server 2008 64 have removed a system tuning parameter that controls memory usage. Without this option, when memory usage approaches 100 percent, I/O intensive applications, especially those such as Nastran that generate very large data files overwhelm the system cache, to the point that there is no physical memory left and the machine will appear to hang.

Description

Avoidance: The work-around is to tell the various I/O intensive applications to bypass the use of system caching for their very large files. This is done by specifying the FILE_FLAG_NO_BUFFERING option in the FlagsAndAttributes argument specified for CreateFile when the file is opened. For MSC.Nastran and MD Nastran, the files for which this bypass is necessary are the SCRATCH and SCR300 files. In nastran this is accomplished by specifying RAW=YES as a SYS keyword for the appropriate files. Note that RAW=YES also requires that BUFFIO be requested instead of the default of MAPIO=YES.) Unfortunately, through a documentation oversight, the use of RAW=YES for Windows is not

Known Error

CR 1-74205731 documented in the IOG. This will be corrected. These SYS options may also be specified by using the SYSFIELD command line or RC File keyword option. Example of these specification on the nastran command is nastran jid MEM=4GB SYSFIELD=SCR*(RAW=YES,BUFFIO=YES,WNUM=32,WSIZE=16MB)

Known Error

CR 1-74218823

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Superelements and Dynamics - EXTSEOUT( DMIGOP2) - SFM 6551 in INPTX2 If external superelements, created with EXTSEOUT(DMIGOP2, are assembled into SOLs 107-112 with multiple dynamic subcases then the run may fail in the second subcase with: *** SYSTEM FATAL MESSAGE 6551 (INPTX2) AN END-OF-FILE WAS DETECTED ON UNIT 48 DURING BINARY INPUTT2 PROCESSING PROGRAMMER INFORMATION: 1. A KEY VALUE WAS BEING READ 2. THE LAST KEY VALUE READ: 0 0*** FATAL ERROR. 0 NO. FORTRAN RECORDS READ = 0 NO. FORTRAN WORDS READ = 0

Description

Avoidance: Insert the following DMAP alter: compile sedceig alter 1 type parm,nddl,logi,n,zuzrl1 $ alter 'if ( gcase' zuzrl1=true $ compile super3 alter 'call extin'(,-1) type parm,nddl,logi,n,zuzrl1 $ np=dloop $ save if ( zuzrl1 ) dloop=2 $ force execution of extin alter 'call extin' dloop=np $ restore

Known Error

CR 1-74241050

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Using REPCASE in SOL 400 gives strange behaviour

Known Error

CR 1-74241050 Using REPCASE in SOL 400 gives strange and unpredictable behaviours. To avoid, do not use REPCASE in SOL 400.

Description

MD 2010 will issue the following error message: *** USER FATAL MESSAGE 601 (IFP1RULE) REPCASE command is not supported for SOL 400 and will be ignored.

Known Error

CR 1-74301311

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Cylindrical Coordinate Frame used for Analysis Coordinate Frame and Reference Coordinate Frame

Description

In the case where GRID specifices both fields 3 and 7 in the same cylindrical coord system and the FORCE for that grid has field 3 of "0" the forces are reversed

Known Error

CR 1-74397581

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

RSSCON type=grid is missing from SOL 600

Description

RSSCON type=grid is not supported in SOL 600.

Known Error

CR 1-74419791

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Linear Contact - BCONTACT - UFM 9058 with SCR=NO Linear contact jobs will fail with the following message when SCR=NO: ^^^ USER FATAL MESSAGE 9058 (SESTATIC) ^^^ THE SOLUTION FOR THE RESIDUAL STRUCTURE AND THE CURRENT SUBCASE DOES NOT EXIST

Description

Avoidance: 1) run with SCR=YES 2) insert the following dmap alter: compile phase1dr $ fix for CR 1-74419791 alter 'lnrcont=(app','' paraml ACTNODS//'trailer'/6/s,n,n3dclgd $ lnrcont=(app='statics' and nocont>0 and not(nonlnr and seid=0) and n3dclgd>0) $

Known Error

CR 1-74428631

Known Error

CR 1-74428631

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Approximate mass ELSUM CTETRA, CHEXA, CPENTA with midside nodes

Description

Mass can be calculated by modules GPWG and ELTPRT. For models containing elements with midside nodes, the values output can be different. Module GPWG uses the mass matrix output from module EMG and gives accurate results. Module ELTPRT is an approximate evaluation which does not use the location of the midside nodes.

Known Error

CR 1-74429111

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL 700 - MATDERO with MXPRES or MNPEPS causes failure in dytranlsdyna - Incorrect Translation

Description

MATDERO with the MXPRES field or MNPEPS field defined is transferred directly (as is) to dytran-lsdyna and this leads to failure in dytran-lsdyna.

Known Error

CR 1-74504344

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Modify UFM 6236 message for the case when all lumped areas specified on a PBCOMP entry are collinear The PBCOMP entry specifies lumped areas of the beam cross section. If all the lumped areas are collinear, the moment of inertia is zero.

Description

In 2010, the text for UFM 6236 has been modified to "FOR BEAM ELEMENT nnn THE MOMENT OF INERTIA IS ZERO ABOUT SOME AXIS, SINCE IYY*IZZIYZ*IYZ=0". This modified message is clear as compared to the previous message.

Known Error

CR 1-74511671

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL 700 test that gets an include file fatal message should stop but continues.

Description

tpl test "istrsts" can not find the include file because the previous job that it depends on did not run correctly.

Known Error

CR 1-74513523

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Documentation/QRG - PBCOMP - SFM 4548 (NBEM1D) Remark 8 of the PBCOMP description of the PBCOMP bulk data entry is incomplete and should have the following sentence added, All of the points (input plus mirrored) should not lie on a straight line.

Description

Otherwise the NLITER module issues the following SFM: *** SYSTEM FATAL MESSAGE 4548 (NBEM1D) SINGULAR (C-KRR) MATRIX ENCOUNTERED FOR BEAM ELEMENT 1 Avoidance: Input values that are not colinear for the Y or Z positions for SYMOPT=5 on the PBCOMP entry.

Known Error

CR 1-74519487

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL 400 heat transfer jobs are issuing swm 3001 (SDRHT) In SOL 400, if the DLOAD does not refer to either a TLOAD1 or TLOAD2 entry, the following message will be issued:

Description

*** SYSTEM WARNING MESSAGE 3001 (SDRHT) THE INPUT DATA BLOCK NAMED DLT AT POSITION 8 DOES NOT EXIST. USER INFORMATION: THIS ERROR IS CAUSED BY ONE OF THE FOLLOWING: 1. THE DATA BLOCK WAS NEVER CREATED. 2. THE DATA BLOCK WAS DELETED. 3. THE DATA BLOCK IS SPECIFIED ON A TYPE STATEMENT IN THE CURRENT SUBDMAP OR A HIGHER SUBDMAP BUT THE CURRENT QUALIFIER VALUES DO NOT MATCH THE QUALIFIER VALUES OF THE DATA BLOCK(S) ON THE DATABASE. USER ACTION: 1. IF YOU ARE EXECUTING AN MSC.SOFTWARE SUPPLIED SOLUTION SEQUENCE AND NOT USING THE ALTER EXECUTIVE CONTROL STATEMENT, THEN CHECK FOR BULK DATA AND/OR CASE CONTROL INPUT ERRORS. IF NO ERRORS CAN BE FOUND, THEN CONTACT Avoidance: Make sure that DLOAD refers to a TLOAD1 or TLOAD2

Known Error

CR 1-74530116

Product

MSC / MD Nastran

Known Error

CR 1-74530116

Corrected Version 2010.1.0 (MD R4) Abstract

SOL 400 - MATM - FATAL NON-LINEAR ELEMENT ERROR In MDR3, MATM data get "FATAL NON-LINEAR ELEMENT ERROR" on Windows XP64(analysis.8664.exe). [test data] tpl : ngnoa01.dat

Description

[error message] analysis ends because of 1 data errors *** FATAL NON-LINEAR ELEMENT ERROR 0FATAL ERROR 1 * * * END OF JOB * * *

Known Error

CR 1-74542868

Product

MSC / MD Nastran

Corrected 2010.1.0 (MD R4) Version Abstract

Optimization/Design Sensitivity - UFM 3032 (ROTOR) unable to find DDVAL A design optimization model with RSPINR referencing DDVAL entries may fail with the following error:

*** USER FATAL MESSAGE 3032 (ROTOR) UNABLE TO FIND SELECTED SET ( 66) IN TABLE (DDVAL ) IN SUBROUTINE (ROTOR). *** USER FATAL MESSAGE 3032 (ROTOR) UNABLE TO FIND SELECTED SET ( 67) IN TABLE (DDVAL ) IN SUBROUTINE (ROTOR). *** USER FATAL MESSAGE 3032 (ROTOR) UNABLE TO FIND SELECTED SET ( 68) IN TABLE (DDVAL ) IN SUBROUTINE Descriptio (ROTOR). n 0FATAL ERROR This error occurs in DESOPT and is caused by a call to FEA with missing datablock EDOM. Avoidance: This alter will provide a proper work-around for V2005.5 and 2007.0 compile desopt list deck alter 'l fea'(2),'' CALL FEA,

Known Error

CR 1-74542868 $..INPUT DATA BLOCKS: ABE,ACPT,,AEBGPDTS,AECOMP,AERO,AEUSETS, , ,BGPDTVU, ,CASECC, CASEDS,CASEM,CASERS,CASES,CASESX, ,CONTROL,CSTMA,CSTMS, , DEQATN,DEQIND, ,DIT,DITS,DMIS,DMINDXS,DRG, , DYNAMIC,DYNAMICS,ECTAS,edom,EDT,EHT, EHTA,ELEMVOL,EMAP,EPT,EPTA,EPTS,EQEXIN,EQEXINS,ETT,EXTDB,,,FORCE, GDGK0,GDKSK,GDNTAB,GEOM1,GEOM1QX,GEOM1S,GEOM2,GEOM2S,GEOM3,GEO M3S, GEOM4,GEOM4S,,GPGK0,GPKSK,GPLS,GPSNTS,,INDTA,,MAPS,MATPOOL,MATPOOLS, MEDGE,MKLIST,MMCDB,MPT,MPTS, ,OINT,PCDB,PCDBS,PCOMPTS,PELSETS, , POSTCDB, ,PVAL,PVT,PVTBC,PVTS, , ,SCSTM,SILS,SLIST,SLT, SPLINE,SPSEL,TABDEQ,TABEVP,TABEVS, ,TRX, , , , ,VGFS, VGQ,VIEWTB,XYCDB,XYCDBS,YG,MPJN2O,MPJSFN2O,AEMPCOMP,AEMONPT,SAEMP RK, STRUCOMP,MONITOR,SAERG0,AEDBSTDX,UXVST,PGVST0,,,,,,XSOP2DIR,,, GEOM1QS,GEOM4QS,SELIST,PVT0,DMONPTA,DMONPTS,SDSRG0,SDARK,PVPERQ, DTIS,DTINDXS,PBRMSD,PBRMS,MP1,MPD1,MP3,STRPLAB,EDTS,YMU,,,,/ $..OUTPUT DATA BLOCKS: , , , , ,AQG,AUA,AUG, , B2DD,B2MG,B2SF, ,BDICT,BELM, ,BGPDTS,BGPDT,BHH, , ,BLAMA, BLAMA1,BMG,BPHA,BSF,BUG, ,CB2DD, , CK2DD,CLAMA,CMDD,CMLAMA,CMPHA,CMPHO,CPHD,CPHH,CPHP, CRJ,CRX, ,D1JK, , ,DAR, , ,DFFDNF, DITID, ,DLT,ECTS,EPSSEDSN,

Known Error

CR 1-74542868 , ,EST, ,FLAMA, ,FOL,FOL1,FPHH,FRL, , , , , ,GM,GOQ,GOT, ,GPECT, , , , K2DD,K2MG, ,K2SF, , , , ,K4MG,K4SF, , , , ,KDICT, ,KELM, KFS,KHH, , ,KMG,KSF,KSS, , LAJJ, ,LAMA,LAMA1,LAMAF,LAMAS,LLL, , LPHD,LPHH,LPHP, , , M2MG,M2SF,MAR, ,MDICT,MEA,MELM,MHH, , ,MJJ, , ,MMG, , ,MSF,MTRAK, , , ,PDF,PDT,PDTDS,PG, ,PHA, ,PHDH,PHF, PHFA,PHG, , , , ,PHQG,PHSA,PJ, , ,PNLH,PPF,PPF1,PPT,PPTDS,PP1DS,PSF,PSF1,PSS,PST, ,PSTDS,PTELEM,QG, , , , , , , , , ,QMG,QMPF,QMPT,QPF,QPT,QR, , , ,TOL,TOL1,TOL2,TR, ,UAJJ, ,UDF,UG, ,,UHF,UHT,UHTDS,UL, ULF, ,ULTDS,UOO,UPF,UPT, , ,USET,USETD, VAFS,VELEM,YPF1,VGFD,VPHFS,WKK,WSKJ, , ,YS,YPO , , ,,,,,,,,,,,,,,,,,,MDPHIQ,MDGOT,MDGOQ,MDVFT,MDMAP, MDGRDRM,MP2SLAB,MP2ST,MP2UGCP,MP3INT,MP3LAB,MP3GPF, MP2A,MP3A,MP2SA,MP3SA,S2A,S3A,SDSA,,,,THETAM/ $..INPUT PARAMETERS: AERO/ADJFLG/AERTYP/ALTRED/APP/AUNITS/AUTOSPC/BUCKCC/CNVFLG/TRUE/ CYCLIC/DCEIGCC/DESCYCLE/DESEIG/DESMAX/DFRQCC/DFRQDSA/DFRSPCF/DMRESD /

Known Error

CR 1-74542868 DROPT/DROPTDS/DSTSPCF/DVRGCC/DTRSPCF/EBIS/ERROR/EXTERSE/FEAOPT/ FIXEDB/FLUIDSE0/FLUTCC/FSCOUP/G/GUSTAERO/HFREQ/IKBAR/IMACHNO/INREL/ IQ/KDAMP/ENFMETH/LASTSEID/LFREQ/LMODES/LUSETS/MCEIGCC/MFRQCC/ MFRQDSA/MODACC/MODECC/MTRNDSA/MTRNCC/NASOUT/NK/NLHEAT/NOPH1/N OPH2/ NOSEDV/OPTIMIZE/PEXIST/PSLOAD/RGSENS/RSONLY/SAERCC/SAERODSA/SEKR/ SELG/SELR/SEMG/SEMR/SKPAMG/SKPAMP/SOLTYP/STATCC/STATDSA/ $..I/O PARAMETERS: S,ADPTEXIT/S,ADPTINDX/S,BOV/S,BMETH/S,CARDNO/S,FREQDEP/ S,FS/S,LUSET/S,METHF/S,MDTRKFLG/S,MODETRAK/S,NMSOL/S,NORSET/ S,NOSASET/S,NSOL/S,PFILE/S,PVALID/S,STATSUB/S,SUPORT/0/DELTAB $

alter 'l fea'(3),'' IF ( NOSEDV>-1 AND NOPALOAD>-1 ) CALL FEA, $.............INPUT DATA BLOCKS: ABE,ACPT,,AEBGPDTS,AECOMP,AERO,AEUSETS, , ,BGPDTVU,CASADJ,CASECC, CASEDS,CASEM,CASERS,CASDSN,CASDSN,CASEXX,CONTROL,CSTMA,CSTMS, , DEQATN,DEQIND,DFFDV,DIT,DITS,DMIS,DMINDXS,DRG,DRSTBL, DYNAMIC,DYNAMICS,ECTAS,EDOM,EDT,EHT,EHTA,ELEMVOL, EMAP,EPT,EPTA,EPTS,EQEXIN,EQEXINS,ETT,EXTDB,FPA,FPG,FORCE, GDGK0,GDKSK,GDNTAB,GEOM1,GEOM1QX,GEOM1S,GEOM2,GEOM2S,GEOM3,GEO M3S, GEOM4,GEOM4S,GPDTS,GPGK0,GPKSK,GPLS,GPSNTS,,INDTA,LCDVEC,MAPS,,, MEDGE,MKLIST,MMCDB,MPT,MPTS,MXOMEG,OINT,PCDB,PCDBS,PCOMPTS,PELSETS ,

Known Error

CR 1-74542868 PMA,POSTCDB,PTGA,PVAL,PVT,PVTBC,PVTS,,R1TABR,SCSTM,SILS,SLIST,SLT, SPLINE,SPSEL,TABDEQ,TABEVP,TABEVS,TPG,TRX,UFOO,UG1PVT, ,UTOO, VGFS,VGQ,VIEWTB,XYCDB,XYCDBS, ,MPJN2O,MPJSFN2O,AEMPCOMP,AEMONPT, SAEMPRK,STRUCOMP,MONITOR,SAERG0,AEDBSTDX,UXVST,PGVST0,ADBINDX, ADBUXV,ADBWJV,ADBFJV0,ADBQKV0,XSOP2DIR,CASEDM,LVTABI, GEOM1QS,GEOM4QS,SELIST,PVT0,DMONPTA,DMONPTS,SDSRG0,SDARK,PVPERQ,,, PBRMSD,PBRMS,MP1,MPD1,MP3,STRPLAB,EDTS,YMU,XINIT,DVPTAB,,/ $.............OUTPUT DATA BLOCKS: ,AEQGDKA,AEQGDKL, , ,AQG,AUA,AUG, , B2DD,B2MG,B2SF, ,BDICT,BELM, ,BGPDTS,BGPDT,BHH, , ,BLAMA, BLAMA1,BMG,BPHA,BSF,BUG,CBDD,CB2DD,CKDD, CK2DD,CLAMA,CMDD,CMLAMA,CMPHA,CMPHO,CPHD,CPHH,CPHP, CRJ,CRX, ,D1JK, , ,DAR,DELS,DELX,DFFDNF, DITID, ,DLT,ECTS,EPSSE, , ,EST, ,FLAMA, ,FOL,FOL1,FPHH,FRL, GDAK, , ,GDKL, ,GM,GOQ,GOT,GPAK,GPECT, GPGK,GPLK,IUXLR, K2DD,K2MG,KZRR,K2SF, , , , ,K4MG,K4SF, , ,KALV,KAZR,KDICT, ,KELM, KFS,KHH, ,KLL,KMG,KSF,KSS,L2RR, LAJJ, ,LAMA,LAMA1,LAMAF,LAMAS,LLL, , LPHD,LPHH,LPHP, ,LSALL, M2MG,M2SF,MAR, ,MDICT,MEA,MELM,MHH, ,MIRR,MJJ, , ,MMG, , ,MSF,MTRAK,

Known Error

CR 1-74542868 ,PA,PD,PDF,PDT,PDTDS,PG, ,PHA, ,PHDH,PHF, PHFA,PHG, , , ,PHILZ,PHQG,PHSA,PJ, PL,PLR,PNLH,PPF,PPF1,PPT,PPTDS, ,PSF,PSF1,PSS,PST, PST1DS,PSTDS,PTELEM,QG, , , , , , ,QKKS, , ,QMG,QMPF,QMPT,QPF,QPT,QR, , , ,TOL,TOL1,TOL2,TR, U2RR,UAJJ, ,UDF,UG, ,,UHF,UHT,UHTDS,UL, ULF, ,ULTDS,UOO,UPF,UPT,URLR,USALL,USET,USETD, VAFS,VELEM, ,VGFD,VPHFS,WKK,WSKJ, ,XTMADJ,YS, , SAERG ,SAERA,SAERL, , ,PLVST,AEDBUXV, MPAERV,MPSERV,MPSIRX, PRBDOFS,AEDBINDX,AERRV,AEURV, UERGV,UEUGV,UXDIFV,WQKV,,MDPHIQ,MDGOT,MDGOQ,MDVFT,MDMAP, MDGRDRM,MP2SLAB,MP2ST,MP2UGCP,MP3INT,MP3LAB,MP3GPF, MP2A,MP3A,MP2SA,MP3SA,S2A,S3A,SDSA,SDSRA,SDSRL,VGFDT,THETAM/ $..INPUT PARAMETERS: AERO/ADJFLG/AERTYP/ALTRED/APP/AUNITS/AUTOSPC/BUCKCC/CNVFLG/FALSE/ CYCLIC/DCEIGCC/DESCYCLE/DESEIG/DESMAX/DFRQCC/DFRQDSA/DFRSPCF/DMRESD / DROPT/DROPTDS/DSTSPCF/DVRGCC/DTRSPCF/EBIS/ERROR/EXTERSE/ 'SENSITIVITY'/FIXEDB/FLUIDSE0/FLUTCC/FSCOUP/G/GUSTAERO/HFREQ/IKBAR/ IMACHNO/INREL/IQ/KDAMP/ENFMETH/LASTSEID/LFREQ/LMODES/LUSETS/MCEIGC C/ MFRQCC/MFRQDSA/MODACC/MODECC/DOMTRAN/MTRNCC/NASOUT/NK/NLHEAT/ NOPH1/ NOPH2/NOSEDV/OPTIMIZE/PEXIST/PSLOAD/RGSENS/RSONLY/SAERCC/DOSAERO/ SEKR/SELG/SELR/SEMG/SEMR/SKPAMG/SKPAMP/SOLTYP/STATCC/DOSTATIC/

Known Error

CR 1-74542868 $..I/O PARAMETERS: S,ADPTEXIT/S,ADPTINDX/S,BOV/S,BMETH/S,CARDNO/S,FREQDEP/ S,FS/S,LUSET/S,METHF/S,MDTRKFLG/S,MODETRAK/S,NMSOL/ S,NORSET/S,NOSASET/S,NSOL/S,PFILE/S,PVALID/S,STATSUB/ S,SUPORT/NNDFRQ/DELTAB $ $

Known Error

CR 1-74547455

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Rotor dynamics : eigen value extraction problem Some eigenvalues are not properly sorted during eigenvalue extraction in SOL 107 with rotordynamics.

Description Avoidance: none Fixed in 2010 Known Error

CR 1-74563841

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL 400 - Fails in in SDR2 after divergence

Description

When a divergent condition is detected, SOL 400 always packs the final iteration resuts for output and post-processing before leaving the NLSOLV module. However, in some cases, such as when a job fails because of material divergence, it may leave NLSOLV without saving all required data. In this case, the job will fail later in the SDR2 module. .

Known Error

CR 1-74623771

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

MDR3 - BCTABLE - Segmentation Error in SOL700 ...

Description

SOL 700 may fail with a segmentation error in dytran-lsdyna or may hang on other systems.

Known Error

CR 1-74623771 Avoidance: Modifying the BCTABLE from 3 pairs instead of 6 allowed the job to run.

Known Error

CR 1-74676639

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

ACMS - EIGR, EIGRL - SFM 3008, SFM 7340 (LNNRIGL) It has been observed in an ACMS eigenvalue analysis with high modal density and a small F2 value specified on the EIGR entry that the job failed with the following misleading error messages: SYSTEM FATAL MESSAGE 7340 (LNNRIGL) UNKNOWN INTERNAL ERROR OCCURRED.

Description

SYSTEMM FATAL MESSAGE 30008 (UTMCOR) MODULE - MDENZO INSUFFICIENT CORE AVAILABLE FOR SUBROUTINE ENZ02 PROGRAMMER INFORMATION: LOCATION KEY = READ IN PHQ 0 FATAL ERROR

Avoidance: The avoidance is to add the following parameter to your input file param,ifzero,x where "x" is lower than min(1.0,F2). where x is a small value like 0.1. X must be less than F2. Known Error

CR 1-74793121

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Documentation: MATEP requires PSLDN1 for solids

Description

In the MD Nastran R3 QRG, the MATEP documentation does not mention that this material model will only work if PSLDN1 is used, and that it will not work with PSOLID alone.

Known Error

CR 1-74874775

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4)

Known Error

CR 1-74874775

Abstract

SSSALTER - SSSALTER library is missing readme file for cditer200a.alt The MD R3 and MSC V2008 deliveries are missing the readme file in the SSSALTER directory for the cditer200a.alt. Avoidance: Here is the readme: $ $ THIS ALTER IS CONFIDENTIAL AND A TRADE SECRET OF THE $ MSC.SOFTWARE CORP. THE RECEIPT OR POSSESSION OF $ THIS ALTER DOES NOT CONVEY ANY RIGHTS TO REPRODUCE OR $ DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE, OR SELL $ ANYTHING HEREIN, IN WHOLE OR IN PART, WITHOUT THE $ SPECIFIC WRITTEN CONSENT OF THE MSC.SOFTWARE CORPORATION. $ Alter to allow simple contact in Design Optimization

Alter Name cditer200a.alt

Purpose Description

Enable CDITER in SOL 200

Solution Sequence SOL 200.

Input File Management Section Normal FMS for SOL 200 Executive Control INCLUDE 'SSSALTERDIR:cditer200a.alt' Case Control Normal case control for DESOPT (DESOBJ, DESSUB, etc.) Normal case control to invoke CDITER (proper SPC and MPC callouts)

Known Error

CR 1-74874775 Bulk Data Normal bulk data for DESOPT (DESVAR, DRESP1, DCONSTR, etc) Normal bulk data for CDITER (PARAM,CDITER,YES SPC, MPC, SUPORT) Output Normal output for SOL 200 Limitations PARAM,CDITER,YES is only valid for ANALYSIS=STATICS. Sample Files All the sample files are a cantilever plate with a gap of -.05 on the free end (grids 111, 211). $.......2.......3.......4.......5.......6.......7.......8.......9.......0 $ $ Cantilevered Beam Made of Plates Model $ $ \201 202 203 204 205 206 207 208 209 210 211 $ Y \*----*----*----*----*----*----*----*----*----*----* $ ^ \| | | | | | | | | | | $ | \| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | $ | \| | | | | | | | | | | $ +--->X \*----*----*----*----*----*----*----*----*----*----* $ \101 102 103 104 105 106 107 108 109 110 111 $ $.......2.......3.......4.......5.......6.......7.......8.......9.......0 The gap is modeled with Constrained Displacements (lingaps or linear gaps). There is 1 design variable and 2 designed properties. DESVAR=T Property T1 = 1.5*T (elements 1-5) Property T2 = 1.0*T DDVAL is used for each run. cditer200-1.dat demonstrates a valid solution for 3 different gap configurations: subcase 20001 loading starts and ends with 2 gaps closed subcase 20002 loading starts and ends with 1 gap open, 1 gap closed subcase 20003 loading starts and ends with 2 gaps open

Known Error

CR 1-74874775 cditer200-2.dat demonstrates convergence when there is no change to gap values (all closed) subcase 20001 loading starts and ends with 2 gaps closed. DDVAL is also used cditer200-3.dat demonstrates convergence when there is a change in gap status. subcase 20001 loading starts with 2 gaps open, ends with 1 gap closed, 1 gap open cditer200-4.dat demonstrates convergence when there is no change to gap values (some open, some closed) subcase 20001 loading starts with 1 gap open, 1 gap closed, ends with same gap open, same gap closed cditer200-5.dat demonstrates convergence when there is no change to gap values (all open) subcase 20001 loading starts with 2 gaps open ends with 2 gaps Note: convergence is slower when there is at least one closed gap. Additional Documentation None.

Known Error

CR 1-74887341

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Optimization - D/MFREQ job with PARAM,OPTEXIT,2 may print asterisk for FREQ/TIME of DRESP2

Description

SOL 200 DFREQ or MFREQ job with PARAM,OPTEXIT,2 may print asterisk for FREQ/TIME of DRESP2. DRESP3 has the same problem.

Known Error

CR 1-74910381

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

Optimization/Aeroelastic Flutter Analysis - Traceback in FA1 module on Windows 32 only The tpl test cpmopt.dat will fail with a traceback in the fa1 module in the Windows 32 MD R3 Nastran release. Avoidance: Run on another platform or version.

Known Error

CR 1-74935310

Product

MSC / MD Nastran

Corrected Version 2008.0.0 (MD R3) Abstract

Optimization/Design Sensitivity - SFM 3007 (DOM9), ILLEGAL INPUT TO SUBROUTINE ADS9P4D A model with a large number of design variables and constraints may fail with the message:

Description

*** SYSTEM FATAL MESSAGE 3007 (DOM9) ILLEGAL INPUT TO SUBROUTINE ADS9P4D Avoidance: Use the DOT optimizer instead. This can be selected by specifying OPTCOD DOT on the DOPTPRM entry.

Known Error

CR 1-74937455

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Fiber Crushing Failure Criteria automatically printed. although not requested on MATM

Description

MDr3 Sol400 jobs using the advanced composite progressive failure model would report on "Fiber Crushing Failure", although this was not requested on the MATM input.

Known Error

CR 1-74941232

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL 700 - DYPARAM,VELMAX,,NO/YES does not work as documented

Description

In SOL 700 the options YES/NO on the DYPARAM entry are not working in MD R3. Only the value for VELMAX will work properly.

Known Error

CR 1-74961191

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Optimization/Design Sensitivity - UFM 3001 in DSAD8 SOL 200 jobs with multiple subcases defining multiple frequency sets but a single boundary condition may fail with USER FATAL MESSAGE 3001 in DSAD8.

Description Avoidance: Applying a dummy SPC set avoids the error at the cost of performing

Known Error

CR 1-74961191 an additional eigenvalue analysis.

Known Error

CR 1-74995551

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Connector Elements - CSEAM - UFM 2042

Description

CSEAM elements with superelements may fail with USER FATAL MESSAGE 2042 (EMG) MISSING MATERIAL TABLE

Known Error

CR 1-74999085

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

sol 400 - MD R3 different to MD R2.1 due to nonlinear WELD although linearly used

Description

The problem was in the nonlinear RBE elements, created from the weld elements by the program. The RBE issue is resolved for MD 2010, and thus the weld elements are now OK.

Known Error

CR 1-75002719

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Complexe eigen value are not correctly sorted

Description

There are different criteria for complex eigenvalue sorting. We will revisit the topic when we fix some known accuracy problems of the complex eigenvalue solvers.

Known Error

CR 1-75002766

Product

MSC / MD Nastran

Corrected Version 2010.1.3 Abstract

SOL 400 + Analysis DCEIG Crashes SOL 400 does not support a rotor+dcieg for linear perturbation analysis.

Description

The job crahses when try to use SOL 400 with Rotor + analysis =DCEIG. No avoidance available for this kind of analysis. The message is issued as

Known Error

CR 1-75002766 BIOMSG: ERROR 201 HAS OCCURRED IN ROUTINE WRITE , FILE INDEX = 0. STATUS = 0 After looking closely at the job, I find that it actually runs the regular linear analysis, DCEIG, with rotor dynamics. To make it run, replace STEP by SUBCASE and add RIGID=LINEAR. A User Warning message is added for the user to avoid the unexpected interruption of the job ^^^ ^^^ USER WARNING MESSAGE 9045 (PHASE0) ^^^ FOR CASE CONTROL, RIGID=LAGRAN, ALL R-ELEMENTS MUST BE IN THE RESIDUAL. OTHERWISE, USE RIGID=LINEAR INSTEAD. ^^^

Avoidance: Use RIGID=LINEAR in SOL 400. Known Error

CR 1-75002840

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

Diffrent size of DBDN database due to diffrent storage methode selected in MPYAD versus memory The size of the DBDN data base could be different depending upon the memory available to the MPYAD process and the MPYAD method selected because of the the memory available. Avoidance: none known.

Known Error

CR 1-75044221

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Adaptivity - HADAPT - Bus Error in MBG module on SGI Irix Jobs with h-adaptivity (HADAPT) on sgi irix will fail in the MBG module with the message:

Description

Receiving signal number 10: Bus error Job aborting...

Known Error

CR 1-75044221 Avoidance: Run the analysis with mode=i8 or run on another machine.

Known Error

CR 1-75059961

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Documentation/QRG - Incomplete CBAR/CBEAM Offset Coordinate System Description The last two sentences of the QRG CBAR description Remark 8 and the CBEAM description Remark 9 reads: "The offset system x-axis is defined from GA to GB. The orientation vector and the offset system x-axis are then used to define the z and y axes of the offset system.," do not make it clear to the user the rule for using the orientation vector and a vector in the direction from Grid A to Grid B.

Description

It is recommended that the following be added to both remarks. A vector is formed from a cross product of a vector going from Grid A to Grid B and the oriention vector to create the offset coordinate z-direction. To obtain a nonzero cross product the orientation vector must not be parallel to both vectors from Grid A to Grid B for the offset coordinate system and End A and End B for the element coordinate system.

Known Error

CR 1-75078841

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

sol106, missing output for an increment that gets UFM 4676 (NMEPD)

Description

In SOL 106 you may get a message that the solution converged and yet get no output. This missing output occurs when: 1. The displacement errors indicate convergence 2. UIM 6186 (NCONVG) SOLUTION HAS CONVERGES 3. UFM 4676 (NMEPD) ERROR EXCEEDS % YIELD SERESS IN ELEMENT.nn The followint warning message has been added: *** USER WARNING MESSAGE 4676 (NLITER) THE RESULTS JUST DECLARED CONVERGED HAVE NOT BEEN OUTPUT DUE TO EXCESSIVE INCREMENT DURING ELEMENT STRESS REVOVERY.

Known Error

CR 1-75178397

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Residual Vectors - RESVEC(NODYNRSP) - UFM 1126, Output datablock

Known Error

CR 1-75178397 BSHHX or B2SHH0X If RESVEC(NODYNRSP)=YES and there exists viscous or modal damping then the following fatal errors will occur: V2005.5: *** USER FATAL MESSAGE 1126 (GNFIST) DMAP MODULE PARTN IS ATTEMPTING TO OUTPUT DATABLOCK 201 NAME = B2SHH0X , WHICH ALREADY EXISTS. USER ACTION: DELETE THE DATABLOCK, OR USE FILE B2SHH0X=OVRWRT

Description

V2007/V2008: *** USER FATAL MESSAGE 1126 (GNFIST) DMAP MODULE PARTN IS ATTEMPTING TO OUTPUT DATABLOCK 201 NAME = BSHHX , WHICH ALREADY EXISTS. USER ACTION: DELETE THE DATABLOCK, OR USE FILE BSHHX=OVRWRT Avoidance: Insert the appropiate version dependent DMAP alter: $ V2005.5 to fix error 1-75178397 compile GMA,nolist alter 'PROCESS RESVEC(NODYN)' FILE B2SHH0X=OVRWRT $ V2007, V2008 to fix error 1-75178397 compile GMAM,nolist alter 'PROCESS RESVEC(NODYN)' FILE BSHHX=OVRWRT compile GMA,nolist alter 'PROCESS RESVEC(NODYN)' FILE BSHHX=OVRWRT

Known Error

CR 1-75215571

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL 400 - NLSTRESS(NLOUT=10) - UFM 608 (IFP1D) In SOL 400, an (NLOUT=nlout id) request under a STEP Case Control Command will incorrectly lead to:

Description

*** USER FATAL MESSAGE 608 (IFP1D) THE SET ID SPECIFIED ON THE ABOVE CARD MUST BE DEFINED PRIOR TO THIS CARD.

Known Error

CR 1-75215571 An example of this input is: STEP 1 NLSTRESS(NLOUT=10)=ALL

Known Error

CR 1-75216341

Product

MSC / MD Nastran

Corrected Version Abstract

KRYLOV solver - Access violation on Windows XP64.

Description

When K2PP exists, "Access violation" occurs.. Many quad elements with buffsize=8193 get "Access violation", but no problem if buffsize is set to 65537.

Known Error

CR 1-75237351

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

Optimization/Design Sensitivity - DOPTPRM - Poor Message, SFM 3001, Missing EDOM in Module DOPR1 In SOL 200, the DOPR1 module can issue SYSTEM FATAL MESSAGE 3001 complaining about a missing EDOM datablock when the actual problem is a missing a SET1 when the DOPTPRM parameter P2RSET specifies a SET1 entry that does not exist.

Avoidance: If a message about a missing EDOM appears, check if the P2RSET parameter is specified and, if so, that the associated SET1 exists. Known Error

CR 1-75259841

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

DYTIMHS entry does not work correctly , d3thdt output was not made . Error: SOL700 can not generate element output time history results. Binary time history output, binout file, does not include the element output time history results. For example, the input card below should generate element output time history results in binout fle. DYTIMHS,,0.0001,,,,,,,+ +,ELEM,232637

Known Error

CR 1-75259841 fixed in 2010

Known Error

CR 1-75343891

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Utilities - buildsss.sh - UFM 701 PRCMPL When building a private delivery databases in Version MDR3, the following error may occur:

Description

*** USER FATAL MESSAGE 701 (PRCMPL) THE NUMBER OF SUBDMAPS BEING COMPILED EXCEEDS THE MAXIMUM ALLOWED NUMBER OF 500 FOR THIS VERSION Avoidance: Compile the additional dmaps in a separate run and add them to the delivery. Contact MSC Support for details on how to perform this.

Known Error

CR 1-75374331

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

External Superlements - EXTSEOUT usage without any A-set, B-set or C-set SFM 3012, SFM 3200 Writing of the DMIGPCH or EXTBULK info in Sol 103 EXTSEOUT using ASMBULK=MANQ, under free-free conditions (no Aset, no Bset), results in the following fatal messages:

Description

a) With DISP data recovery: BIOMSG ERROR 3012 (QOPEN), after resvec eigenvalue solution. b) With out DISP: SFM 3200 Logic error 5 in BDYINC, after resvec eigenvalue solution. Notes: 1) Works fine w/ DMIGOP2 no EXTBULK 2) Works fine w/ Bset's added 3) Same errors w/ manual SPOINT/Qsets vs AUTOQSET 4) Same errors w/ versions 2005.5.2, 2007.1.1, 2008.0.0 5) Similar errors (BIOMSG 3021 vs 3012) w/ DMIGOP2 & EXTBULK (2nd attachment) Avoidance: Use DMIGOP2 without EXTBULK.

Known Error

CR 1-75410871

Known Error

CR 1-75410871

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

External Superelement and Restarts - EXTSEOUT(DMIGPCH) - missing output and wrong answers In restart run with EXTSEOUT(DMIGPCH), the operations which produce the DMIG entries in the punch file are skipped. Avoidance: Insert the following DMAP alter:

Description

compile extout $ alter 1 $ putsys(1,109) $ alter 'IF ( KOUT.*MATMOD'(,-1) $ matprt x_kaa// $

Known Error

CR 1-75435591

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Documentation/QRG - Missing description of PARAM,FLUIDNE The description of PARAM,FLUIDNE is missing from the QRG. PARAM FLUIDNE (Default=500)

Description

The Householder method of eigenvalue extraction is more reliable and is automatically selected for the fluid’s system modes if the acoustic cavity is defined in a superelement and there exist fluid boundary points. The switch to Householder occurs if the number of estimated fluid modes is less than or equal to the value specified by PARAMeter FLUIDNE.

Known Error

CR 1-75435883

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

In sol111 without ACMS summary(Before augmentation) of real eigenvalue matches..But not with ACMS. For a job run with ACMS, the eigenvalue table before and after augmentations may not match.

Description

Possible dmap avoidance: compile invlan alter 'Lamx lmt,/lama,/neigv', '' $ Lamx lmt,/lama,/neigv/1 $

Known Error

CR 1-75435883 Fixed in 2010

Known Error

CR 1-75553921

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL 700 - DYPARAM,LSDYNA,BINARY,D3PLOT is not effective.

Description

DYPARAM,LSDYNA,BINARY,D3PLOT to control output time interval isn't effective in SOL 700. Avoidance: Use PARAM,DYDTOUT.

Known Error

CR 1-75637608

Product

MSC / MD Nastran

Corrected Version Abstract

Rotordynamics UNBALNC entry in frequency response (SOL 108 or SOl 111) may result in null load If the UNBALNC entry is used to define an out of balance load on a rotor in frequency response (SOL 108 or SOL 111), and the ID of the reference rotor on which the out of balance load is defined is not the lowest ID of all rotors, this will result in a null load being generated for the out of balance load.

Description Workaround: Either use an RLOAD1 combination with proper phase relationship to generate a rotating load, or make sure the reference rotor (on which the UNBALNC entry applies its load) is the lowest ID of all rotors in the model. Known Error

CR 1-75641588

Product

MSC / MD Nastran

Corrected Version GL Abstract

Nonlinear Heat Transfer - Large # of load cases in sol159 may fail in TAHT A SOL 159 with a large number of load cases may fail in TAHT.

Description

SJF's comments: this is a user error cause by a duplicated TLOAD1 ID. We cannot trapped this error because this is pass ifp already.

Known Error

CR 1-75737851

Product

MSC / MD Nastran

Known Error

CR 1-75737851

Corrected Version 2010.1.0 (MD R4) Abstract

Dynamics - viscous damping, SOLs 110, 111, 112, 145, 146, 200 - Wrong Answers If a model contains a very small number of elements with viscous damping such that the density of the reduced damping matrix is less than .01% then the viscous damping will be ignored resulting in wrong answers.

Description

Avoidance: Insert the following DMAP alter: compile atbc alter 'PARAML.*NZBV' PARAML NZBV//'null'//S,N,fullnzbv $ IF ( DENSbV=10000 and fullnzbv [[ $cmdname = ${prod}[1-9][0-9]* && -n $1 ]] && { 493c493 < [[ $cmdname = $prod[1-9][0-9]* ]] && { --> [[ $cmdname = ${prod}[1-9][0-9]* ]] && {

Known Error

CR 1-80142500

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Documentation/QRG - AXIC - H=0 Should be allowed

Description

The documentation for AXIC entry indicates H must be greater than 0. A value of 0 indicating that only results for the 0th harmonic are desired is allowed.

Known Error

CR 1-80179842

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Documentation/QRG - CONTRLT - Delay field incorrectly documented as must be less than 0.

Description

The QRG documentation for the CONTRLT entry incorrectly documents that the delay field must be less than 0. The delay entry must be positive (Real > 0; Default = 0)

Known Error

CR 1-80302741

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

PBARL doesn't work well A SOL 700 model with PBARL and small radius generates an error in MD R3.

Description

*** Error Part 2 has material type 1 and uses beam integration rule 1 which references a part with material type 0 The material types must be all the same, both for the material referenced by the element PID and for all the PIDs referenced on the integration rule. PBAR and PBEAM use the resultant beam (LS-DYNA beam type 2) and PBARL and PBEAML use the Hugh-Liu beam (LS-Dyna beam type 1). The specific model that this error occured also benefited from increasing the radius.

Known Error

CR 1-80400222

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

STRESS request in sol103 external SE givies fatal1013

Description

If stress output is requested for an external superelement in SOL 103, FATAL 1013 may occur.

Known Error

CR 1-80400222 Avoidance: Remove the STRESS output request for the external superelement.

Known Error

CR 1-80411679

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

NLRGAP in nonlinear harmonic response SENLHARM with a TABLED5 not using table values In a nonlinear harmonic response analysis (SOL SENLHARM or SOL 128), if the model contains NLRGAP entries that reference any TABLED5 entries, the values specified on the TABLED1 entry referenced by the TABLED5 entry are ignored.

Description

Avoidance: Add the following DMAP alter to SOL SENLHARM ECHOOFF $ COMPILE SENLHARM NOLIST $ ALTER 'ROTRUTL DYNAMICS' $ IF (UVAFLAG=1 OR UVAFLAG=4 OR UVAFLAG=5) UVAFLAG=UVAFLAG+2 $ ENDALTER $ ECHOON $

Known Error

CR 1-80499448

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

SOL200 job with DRESP1 on modal frequency and MODTRAK may produce incorrect DRESP1 SOL200 jobs withDRESP1 on modal frequency and MODTRAK may produce punched DRESP1 in the wrong format. Those punched DRESP1 can not be utilized in subsequent SOL 200 jobs. Avoidance: None.

Known Error

CR 1-80499950

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL400 CQUADR TEMP(LOAD) STRESS - UFM 4016 SOL 400 - using CQUADR - UFM 4016

Description

*** USER FATAL MESSAGE 4016 (GETEMP) THERE ARE NO TEMPERATURES FOR QUADR ELEMENT 27890215 IN SET 2

Known Error

CR 1-80499950 Client had a job with Temperature(LOAD) in SOL400 for CQUADR elements and stress data recovery. Avoidance : using CQUAD4. This error is now fixed in MD2010

Known Error

CR 1-80502200

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

MATT1 and MATS1 cards in deck can cause a fatal error due to ID sequence If both MATT1 and MATS1 entries exist in your input file and a MATT1 ID is higher than the MATS1 entry, the run may fail with:

Description

*** USER FATAL MESSAGE 2076 (PREMAT) TABLES1 BULK DATA ENTRY ID 5000101, WHICH IS REFERENCED BY MATS1 ENTRY ID 2, IS INCORRECTLY DEFINED FOR NONLINEAR ANALYSIS. Avoidance: use a higher id for the MATS1 than for the MATT1

Known Error

CR 1-80511832

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Acoustic Analysis - enforced motion, ACMS - UFM 5423 Using DOMAINSOLVER ACMS in acoustic analysis with enforced motion may produce the following fatal message:

Description

*** USER FATAL MESSAGE 5423 (SADD5) ATTEMPT TO ADD INCOMPATIBLE MATRICES FILE# COLS ROWS FORM TYPE NZWD DENS TRAILER FOR PDF1 IS 101 50 27483 2400 TRAILER FOR PYHF IS 102 50 27484 2 4 18652 1697 Avoidance: Insert the following DMAP alter: compile fdrmgen alter 'nm1=','' if ( noue>-1 ) then $

Known Error

CR 1-80511832 nm1=noue+nullfeig $ else $ nm1=nullfeig $ endif $

Known Error

CR 1-80526397

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Dynamics - virtual mass, SPCD, PARAM,VMOPT, 0 or 2 - Wrong answers In SOLs 111 and 112 with PARAM,VMOPT,0 or 2, the virtual mass effects are ignored in the calculation of equivalent loads due to enforced motion using the SPCD method and wrong answers may result. This may also occur in SOL 200 with ANALYSIS=MFREQ. Avoidance: Insert the following DMAP alter: compile sekmr alter 'dbstatus vny'(,-1) CALL MGEN1 Gge , , , , , bec ,cee ,mee ,mec , , / mjex ,Mjjv / ERROR /-1 /seid /false $

Description

equivx mjjv/mnnv/nomset $ if ( nomset>-1 ) mce2 uset,gm,mjjv,,,/mnnv,,, $ upartn uset,mnnv/,msfv,,mssv/lnset/lfset $ add5 msfv,msf,,,/msfw $ equivx msfw/msf/-1 $ add5 mnnv,mnn,,,/mnnw $ alter 'call getxay.*mnn','' call getxay mnnw,vny,vno,vna,goy,goa/may/nooset $ call xMATREDU mjjv,USET,GM,GOa/maav,, $ call dbstore maav,,,,//0/0/' '/0 $ compile modefsrs alter 'call getay','' call dbfetch /maav,,,,/0/0/0/0/0 $ add5 maav,maa,,,/maaw $ call getay lyy,kay,vay,vya,baa,maaw,k4aa,kdaa,aaa, bay,may,k4ay,kday,aay,ys,uset,nzyg,vafs/ day,bdsf,mdsf,k4dsf,kddsf,adsf,ys1/ nooset/-1 $ endalter

Known Error

CR 1-80599782

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

XDB results content is incorrect when duplicate identifications are present

Description

All elements ( for example CBAR, CMASSi or RBAR) that have data recovery responses must have unique identifications. This requirement is now more strictly enforced when PARAM,POST,0 is utilized.

Known Error

CR 1-80624021

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Yield stress for Implicit Creep model in MATEP card isn't transformed into Marc input file

Description

Yield stress for Implicit Creep model in MATEP card isn't transformed into Marc input file. For viscoplastic material - defined through user subroutine ucrplw.f option in MATVP card, it's very general to define plastic behavior through "implicit creep" option in MATEP card. For "implicit creep" option in MATEP. it would be also necessary to input yield stress as the format below, MATEP,1,,,,ImpCreep,,,,+ +,ImpCreep,4.92e7 However, the transformed Marc input file would just show "zero" at the equivalent entry.

Known Error

CR 1-80625441

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

PARAM,ENFMOTN,ABS ignored for internal SE with no output request in Residual In SOL 111 with SPCD enforced acceleration and f there is no data recovery requested in the residual for at least one of the residual boundary grid displacement,then the displacement, velocity, and acceleration results for superelements will be computed in relative instead of absolute--which includes the fixed base motion. Avoidance: Request at least 1 boundary displacement in the residual for each of the superelements where data recovery is required.

Known Error

CR 1-80626457

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4)

Known Error

CR 1-80626457

Abstract

The COPTB entry on the BCBODY option is ignored

Description

In MD R3, the COPTB entry on the BCBODY option is ignored. The workaround is to define COPTS1/COPTM1 or COPTS/COPTM on the BCTABLE option.

Known Error

CR 1-80876934

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

DOPTPRM P2CR output may not in ascending order of constraint values if P2CR on DOPTPRM is greater then the number of retained constraints, P2CR output will not be in the ascending order of constraint values. Instead, it is in the order of internal constraint ID which is the same as P2CR is not specified. Avoidance: None.

Known Error

CR 1-80926331

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

A topology opt run with a FRMASS response with multiple properties fails with SFM6144 (MERGE) In v2008, when a topology optimization job specifies a FRMASS DRESP1 response with multiple properties, it fails with the following error message:

Description

*** SYSTEM FATAL MESSAGE 6144 (MERGE) THE SIZES OF THE INPUT MATRICES AND PARTITIONING VECTORS ARE INCOMPATIBLE. SPECIFICALLY: The number of columns in FRMDS is not equal to the number of zeros in partitioning vector SCRATCH The number of columns in SCRATCH is not equal to the number of non-zeros in partitioning vector SCRATCH This bug was found MD R3 and fixed in MD2010 No avoidance available.

Known Error

CR 1-80975071

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Numeric roundoff on 32 bit machines for large time steps for roror angle

Known Error

CR 1-80975071 defined as single precision

Description

The rotor angle for the UNBALNC loading entry is calculated using single precision. It is possible, that for a large number of time steps, this will result in numeric roundoff on 32-bit systems. The problem does not occur on 64-bit systems.

Known Error

CR 1-81032458

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Restart SOL (110-112,145,146, 200) following by a RESVEC=YES in SOL 103 results in wrong answers If RESVEC=YES is specified in a SOL 103 cold start and followed by a restart into a modal solution (SOLs 110-112, 145, 146, 200) with new loads or enforced motion then the residual vectors may not be recomputed. This bug was found in MD R3 and fixed in MD2010

Description

Avoidance: Insert the following DMAP alter: compile modefsrs alter 'call resveca'(,-1) delete /phsa,mis,lammats,lamas, $ This error was fixed in MDR4 V2010.0.0

Known Error

CR 1-81043801

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Trouble with QBDY3 boundary conditions

Description

An error occurs when QBDY3 in combination with Marc element type 198 with one collapsed node (making it a triangle instead of a quad) is specified.

Known Error

CR 1-81055041

Product

MSC / MD Nastran

Corrected Version GL Abstract

CELAS recovery with resvec=yes. Limitation of the Large Mass Method

Description

For data recovery for the structural line and surface elements or scalar elements there is no provision for a modal damping in the element force calculation. While this is a limitation, it is there because there is no physical way to relate a global modal damping to a local force value. This

Known Error

CR 1-81055041 is a Limitation to the Large Mass Method of analysis.

Known Error

CR 1-81081056

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL 400, no intermediate output if NLPARM and TSTEPNL with same ID

Description

If SOL 400 with ANALYSIS=NLSTAT has same ID's for both NLPARM and TSTEPNL bulk data entries, the "NO" field of TSTEPNL is used. In some cases, this may result in missing intermediate output.

Known Error

CR 1-81083267

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Acoustics - DMP, SOL 108 - PFPANEL, PFMODE, and PFGRID - Missing output If dmp>1 is specified in SOL 108, then the resulting output from PFPANEL, PFMODE, and PFGRID from the slaves will be missing. Avoidance: Insert the following DMAP alter which also fixes similar errors for ACFPMRESULT, ACPOWER, and INTENSITY results:

Description

compile sedfreq alter 'call super3' DBSTATUS AFPMLIST//S,N,NOAFPM $ PARAML CASEf//'DTI'/-1/613//S,N,INTENSET $ PARAML CASEf//'DTI'/-1/416//S,N,ACPOWSET $ paraml casef//'dti'/-1/512//s,n,pfmodes $ paraml casef//'dti'/-1/519//s,n,pfmodef $ paraml casef//'dti'/-1/528//s,n,pfpanel $ paraml casef//'dti'/-1/535//s,n,pfgrid $ if ( nproc>1 and nfreqt>1 ) then $ if ( pfmodes=-1 or pfmodef=-1 or pfpanel=-1 or pfgrid=-1 ) call disfreq fol,udf,pdf,,,ypf,ypf1/ udf0,pdf0,,,ypf0,ypf10/ nfreqt/nproc/procid/false $ if ( noafpm=1 or intenset1 ) then $

Known Error

CR 1-81083267 CALL PFACT CASEF ,BGPDTS ,USET ,USETD ,SILS , GOT ,GOQ ,GM , , , ,UDF ,FOLt ,PDF ,VGFS , ,CKDD ,CBDD ,CMDD ,ABE , AGG , ,YPF10 ,RPY ,YPF0 / SMPF ,SMPFD ,OSMPF1 ,AFMPF ,AFMPFD , OAFMPF1 ,ASMPF ,ASMPFD ,OASMPF1 ,APMPF , APMPFD ,OAPMPF1 ,APPF ,APPFD ,OAPPF1 , AGPF ,AGPFD ,OAGPF1 / NOASET /NOOSET /NOQSET /NOTSET /NOMSET / NOA /NOUE /APP /SOLTYP /FS / FONLY $ IF ( intensetnleft ) then $ istart= (procid-1)*nf + nleft + 1 $ else $ istart= (procid-1)*nf + procid $ endif $

Known Error

CR 1-81083267 nzero= nfreqt - ifreq + 1 $ matgen ,/expand/4/1/nrow//ifreq/nzero/istart $ $ expand to complete freq/load list merge ,,,udf,,expand,/udfe/1 $ merge ,,,pdf,,expand,/pdfe/1 $ merge ,,,ppf,,expand,/ppfe/1 $ merge ,,,qsgf,,expand,/qsgfe/1 $ merge ,,,qmgf,,expand,/qmgfe/1 $ merge ,,,ypf,,expand,/ypfe/1 $ $ weave on master DISUTIL udfe,,,/udf0///-8 $ DISUTIL pdfe,,,/pdf0///-8 $ iproc=2 $ do while ( iproc1 if ( scatter ) then $ $ re-broadcast to all slaves DISUTIL udf0,,,/udf2///3 $ DISUTIL pdf0,,,/pdf2///3 $ DISUTIL ppf0,,,/ppf2///3 $ DISUTIL qsgf0,,,/qsgf2///3 $ DISUTIL qmgf0,,,/qmgf2///3 $ DISUTIL ypf0,,,/ypf2///3 $ if ( procid>1 ) then $

Known Error

CR 1-81083267 equivx udf2/udf0/-1 $ equivx pdf2/pdf0/-1 $ equivx ppf2/ppf0/-1 $ equivx qsgf2/qsgf0/-1 $ equivx qmgf2/qmgf0/-1 $ equivx ypf2/ypf0/-1 $ endif $ procid>1 endif $ return $ end $ disfreq

Known Error

CR 1-81093341

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL600 fails in translation of TITLE or LABEL line containing an '=' sign

Description

When running SOL600 in MDR3 (as well as 2007), if there is an '=' sign in the Case Control TITLE or LABEL command, the translation fails with the only indication of an error in the NASTRAN .log file

Known Error

CR 1-95056651

Product

MSC / MD Nastran

Corrected Version 2008.0.4 Abstract

Description

Aeroelastic Analysis - CAERO1, CAERO2 - Wrong Answers on Windows 32. The Windows 32 release of MD R3 Nastran and MSC.Nastran V2008 may produce wrong answers or fail in AMG with a floating point exception error for subsonic aerodynamics using the default value of quarticdlm=0 for doublet lattice aerodynamics (CAERO1 and/or CAERO2 bulk data entries exist). Avoidance: Set NASTRAN QUARTICDLM=1 in a system rc file to insure avoidance for all runs. The quarticdlm =1 answers may be slightly different than the quarticdlm=0 answers, but the quarticdlm=1 answers are considered to be more accurate.

Known Error

CR 1-95893346

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Different displacement results depending on size of SET during ADAMSMNF generation

Description

For sparse data recovery during ADAMS Flex operations, displacement

Known Error

CR 1-95893346 output could be different depending upon the content of the SET definition. Avoidance: Use DISP=ALL request.

Known Error

CR 1-97043831

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Linux IPF version of MSC.Nastran V2008 missing library on SGI Altix system Linux IPF version of MSC.Nastran V2008 onto an SGI Altix system and obtained a message that there was a missing library, /msc/nast2008r1_ipf/msc2008/linuxipf/nastran: error while loading shared libraries: libunwind-ia64.so.1: cannot open shared object file: No such file or directory.

Description This bug was found in MD R3 and is fixed for MDR4 V2010.0.0 Avoidance: MSC Delivers this file in the linuxipf/i8 directory. To run on RHEL4, please: ln -s $MSC_BASE/md2008/linuxipf/i8/libunwind-ia64.so.1 $MSC_BASE/md2008/linux Known Error

CR 1-97136055

Product

MSC / MD Nastran

Corrected Version GL Abstract

UFM 3060 (SCA Service Loader) Unable to obtain licenses for SCA.MDSolver.System.PrintServer MDr3 will issue a misleading error message if no MD_Nastran feature is available (either it is missing from the license file or the license server is down).

Description

*** USER FATAL MESSAGE 3060 (SCA Service Loader) - AUTHORIZATION ERROR *** UNABLE TO OBTAIN LICENSES FOR SCA.MDSolver.System.PrintServer PLEASE REFER TO THE LOG FILE FOR ADDITIONAL DETAILS

Known Error

CR 1-97302570

Product

MSC / MD Nastran

Corrected Version GL Abstract

Displacements are off in the fifth or sixth significant place in mode I4 as compared to mode I8

Description

Inaccuracies in displacements may occur on mode=i4 machines because of

Known Error

CR 1-97302570 single precision material property processing. These inaccuracies are typically noted in the 5th or 6th decimal place of the displacements. The precision is improved when mode=i8 is used. The reason is that material properties are calculated in single precision across all platforms - this limitation will remain so.

Known Error

CR 1-98531631

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL-400 STEP's, incorrect Title/Subtitle/Label or missing nonlinear stress output SOL-400 using STEP's may have incorrect Title/Subtitle/Label or missing nonlinear stress output. 1) In SOL-400, if TITLE/SUBTITLE/LABEL was specified in any STEP, then the last TITLE/SUBTITLE/LABEL was used for all STEP's. For example, SUBCASE 100 LABEL=MSC STEP 1 LABEL=ELASTIC STEP 2 $ (no LABEL) STEP 3 LABEL=PLASTIC STEP 4 $ (no LABEL)

Description

will result in "PLASTIC" being used as LABEL for every STEP. 2) When NLSTRESS is not specified and STRESS(PLOT) is given, then it's equivalent to NLSTRESS(PLOT,PRINT) unless TSTEPNL is also present. This has been documented in QRG under "STRESS" case-control section. It was done correctly in most cases, but not in some. For example: SUBCASE 100 $ no STRESS or NLSTRESS here or above !! STEP 1 STRESS(plot) $ implies NLSTRESS(plot,print) which was done correctly before. STEP 2 NLSTRESS(plot) $ no NLSTRESS print which was correct. STEP 3 STRESS(plot) $ should also imply NLSTRESS(plot,print), but was NOT !!

Known Error

CR 1-98531631 As a result nonlinear stress output was previously missing from STEP 3 in this case.

Known Error

CR 1-99838960

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

CTRIA element with hyperelastic material properties handled incorrectly in SOL 600

Description

When CTRIA elements with 2Dsolid formulation are defined with hyperelastic material properties, the Marc translator creates type 6 elements. Hermann elements (type 155) should be used. (Workaround : define PARAM,MRALIAS,006155)

Known Error

CR 1-105794811

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL 400 - BCONTACT, UNGLUE - Stress based contact separation does not work in this example Hi per, i fixed in cl. 52898 on march 11 2009.

Description

If stress based contact separation is selected by specifying IBSEP on the BCPARA entry, incorrect results may occur. In one example the contract stresses were unexpectedly zero and no separation took place. Avoidnace: Use force based seperation.

Known Error

CR 1-105967515

Product

MSC / MD Nastran

Corrected Version Abstract

SFM 3007 Appears in SOL 101with K2GG command and GPFORCE/MONITOR Requests are Made Since 2008.0.0, a static solution, SOL 101, yields the following message multiple times (see below) when GPFORCE and MONITOR output is requested using MONPNT3 with ASM for the XFLAG field in the bulk data and then the expected answers are printed.

Description *** SYSTEM FATAL MESSAGE 3007 (GPFDR) ILLEGAL INPUT TO SUBROUTINE GPFPSC

Avoidance: None

Known Error

CR 1-105967719

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

SOL 101 with multiple SUBCASEs and MONPNT3 may have SUBCASE ID mislabelled in MONITOR output For SOL 101 job with multiple SUBCASEs and MONPNT3, the MONITOR output may not have correct SUBCASE ID priinted. Instead of SUBCASE ID, it prints SUBCASE sequence number. Avoidance: None.

Known Error

CR 1-105967819

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Superlements and Dynamics - AUTOQSET, RSSCON, shell normals - GP4 Module, SFM 3011 The presence AUTOQSET, RSSCON, and shell normals may cause SFM 3011 and UFM 6692 to be issued: *** SYSTEM FATAL MESSAGE 3011 (GP4) ATTEMPT TO WRITE A TRAILER ON FILE 204 WHEN IT HAS BEEN PURGED or it may also result in this message:

Description

*** USER FATAL MESSAGE 6692 (GP4RS1) BULK DATA ENTRY RSSCON CAN NOT FIND ELEMENT IDS, USER ACTION: CHECK SUPERELEMENT STRUCTURE. *** SYSTEM FATAL MESSAGE 3001 (GP4) THE INPUT DATA BLOCK IN POSITION 11 DOES NOT EXIST. Avoidance: Include the following DMAP alter compile augqset alter 'gp4 ','' type db gpsnts $ GP4 CASE,GEOM4,eqexin,SIL,GPDT,BGPDT,CSTM,,,,geom2,,,gpsnts,geom1/ RMG,Yg1,USET0,gpsntn/ LUSET/S,N,NOMSET/0/S,N,NOSSET/0/S,N,NORSET/ nskip/0/0/0/0/SEID//sebulk $ endalter

Known Error

CR 1-107539213

Product

MSC / MD Nastran

Known Error

CR 1-107539213

Corrected Version 2010.1.0 (MD R4) Abstract

Description

Parallel Processing - SYSTEM(107) - Traceback in READ with SMP The Windows 32 bit version of MD Nastran R3 (Version 2008.0.0 and 2008.0.1) may fail in the READ module with a traceback when SMP parallel is selected by setting SYSTEM(107) greater than 1. Avoidance: Do not set SYSTEM(107) greater than 1.

Known Error

CR 1-108130295

Product

MSC / MD Nastran

Corrected Version GL Abstract

Description

Dynamics - PARAM,MODACC, superelements - Wrong answers With PARAM,MODACC, the displacement results for all residual structure GRIDs, including superelement boundary GRIDs include the modal acceleration method adjustments. But displacement results for upstream superelement at same boundary GRIDs do NOT include the modal acceleration method adjustments. Subsequent derivative results (internal DISPLs, stresses) for the upstream SEs are based upon the un-adjusted boundary responses and match runs w/out Modal Aceleration. Avoidance: None

Known Error

CR 1-108542056

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL 400 linear perturbation with normal modes analysis fails with Eigensolver.

Description

1. SOL 400 linear perturbation of normal modes with contact got a FATAL error without other information. 2. The error message has no ID with it. 3. This is an internal code misfit and it has been fixed in 2010

Known Error

CR 1-108542589

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Aeroelastic Analysis - SOL 146 w/ SESET and External Parts SE - UFM 3005 in FRRD2 module

Known Error

CR 1-108542589 An aeroelastic response analysis using Lagrange multipliers for enforced motion and containing an External Parts SE and a SESET superelement, fails in the FRRD2 module with a fatal error: *** USER FATAL MESSAGE 3005 (FRRD2) ATTEMPT TO OPERATE ON THE SINGULAR MATRIX (NONE) IN SUBROUTINE FRRD2

Description

Prior to the fatal error a warning message is issued for the DMIG for for the Lagrange multiplier. *** USER WARNING MESSAGE 2070 (MTRXIN) REQUESTED DMIG MATRIX ENFORCE IS UNDEFINED. Prior to the UWM 2070 a UFM 2065 is issued *** USER FATAL MESSAGE 2065 (MTRXIN) UNDEFINED GRID POINT 2000000009 ON DMIG ENTRY. but the job keeps running. Avoidance: Convert the SESET superelement to a PART supelement.

Known Error

CR 1-109316059

Product

MSC / MD Nastran

Corrected Version 2010.1.1 Abstract

Parallel Processing - DMP - segmentation fault When running dmp, if there is a communication/authentication problem, the nastran command program may issue the following warning:

Description

*** USER WARNING MESSAGE (pgm: nastran, fn: init_rmt_command) hosts=na-nastdev2:na-nastdev4 (command line[6]) Unexpected failure of remote execution request. and then terminate with a segmentation fault. Avoidance: none.

Known Error

CR 1-110722355

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Acoustic example of box with a flap filled with acoustic fluid produced incorrect results in SOL107

Known Error

Description

CR 1-110722355 Acoustic example of box with a flap filled with acoustic fluid produced incorrect results in MDR3 V2008.0.1. The modes calculated were different as compared to V2005.1.0 and there were missing modes. This bug was foud in MD R3 and fixed in MD2010 No avoidance

Known Error

CR 1-112137330

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL 112, rigid body acceleration gives no excitation error, runs in SOL 109 Model has rigid body acceleration. All nodes in the model have acceleration in DOF 3. SOL 112 run fatal with

Description

*** USER FATAL MESSAGE 3046 (TRD1) THIS TRANSIENT RESPONSE ANALYSIS HAS NO EXCITATION SPECIFIED FOR IT. APPLIED LOADS, ENFORCED MOTION, INITIAL CONDITION AND NON-LINEAR FORCES ARE ALL NULL. THE RESULT WILL THEREFORE BE A ZERO SOLUTION. Same error is reported even if the magnitudes of the accelerations are different (not rigid body accleration). It only seems to matter that all nodes have an SPC for DOF 3. If one node does not have an acceleration, the job will run.

Known Error

CR 1-121007791

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

MRCONVER,11 incorrect translation

Description

PARAM,MRCONVER,11 had an incorrect translation. This problem has been fixed for the 2010.1 (MDR4) release.

Known Error

CR 1-121007800

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

output of many MARCIN

Description

When many MARCIN was specified, it is output halfway by marc.dat. It is output only to the 10811 lines though the user is using MARCIN of

Known Error

CR 1-121007800 11588 lines. fixed in 2010

Known Error

CR 1-123457311

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

A static aero optimization job fails with UFM6482 with rtypes=spcforce,ese, totse, gpforce, gpforcp In v2001, If a static aero optimization job invoke any of the above reponse types in a static aeroelastic subcase, it will result in an error of the form: USER FATAL MESSAGE 6482 (DOPR3R)

Description

FOR SUBCASE 1, THE ANALYSIS TYPE IS SAERO BUT THE DESSUB COMMAND REFERENCES AN INCOMPATIBLE DRESP1 ENTRY WITH RID = 20490 AND RTYPE = SPCFORCE. User Avoidance: There is no avoidance, the reference to the unsupported rtypes must be removed.

Known Error

CR 1-126404681

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

A job with triangular axisymmetric solid element (CTRIAX) stops. A Sol 400 job with triangular axisymmetric solid element (CTRIAX) stops.

Description

Avoidance: No avoidance available

Known Error

CR 1-129429251

Product

MSC / MD Nastran

Corrected Version Abstract

CWELD, CFAST, and CSEAM may give bad results when connecting higher order shell elements This problem related to CQUAD8 and CTRIA6 shell elements.

Description

CWELD, CFAST, and CSEAM may give bad results when connecting higher order shell elements and their use should be avoided when associated with CQUAD8

Known Error

CR 1-129429251 and CTRIA6 shell elements patches.

Known Error

CR 1-131604681

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

CQUADR/CRIAR with PCOMP and TEMP(LOAD) -SFM 4276 CQUADR/TRIAR with PCOMP using TEMP(LOAD)-SFM 4276 *** SYSTEM FATAL MESSAGE 4276 (BCKREC) ERROR CODE 3021 PID= 0 *** USER INFORMATION MESSAGE 4276 (BCKREC)

Description

This error was observed with QUADR/TRIAR elements with PCOMP data requesting stress output. The first subcase has no TEMP(LOAD) and a later subcase has TEMP(LOAD). An avoidance would be to put the TEMP(LOAD) in the first subcase. This error is now fixed using MD2010

Known Error

CR 1-132270571

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

Frequency Respons, TSTEP with 1 excitatation freq - wrong answers in IFT, Inverse Fourier Transform In a frequency response analysis (direct or modal) where the user specifies a TSTEP entry in the case control that references a TSTEP bulk data entry, the analysis will perform an inverse Fourier transform of the frequency response and output the results in the time domain. If the analysis consists of only one excitation frequency, the inverse transform is not performed correctly and the peak response will show a factor of 2*f too great, where f is the excitation frequency. Avoidance: Specify at least 2 excitation frequencies if the inverse Fourier transform is to be used.

Known Error

CR 1-135879841

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

sol600 - MRCONVER,11 is incorrect translation

Description

When PARAM,MRCONVER,11 is inserted by 600, the conversion of BCTABLE is

Known Error

CR 1-135879841 incorrect. This has been corrected for the 2010.1 (MDR4) release.

Known Error

CR 1-151570722

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

nonlinear corner strains for CQUAD4 Remark 1 of the STRAIN output request in the QRG should read as follows:

Description

1. Fully accurate nonlinear strains for nonlinear elements are requested by the STRESS command and appear in the nonlinear stress output. In SOLs 106 and 129, if LGDISP ≥ 0 the center, and if requested for CQUAD4 the corner, strains are computed from the displacements alone and are only approximate. If LDDISP=-1 and material nonlinear then no STRAIN output will be created. In SOL400, if enhanced material options are used, the computed strains are accurate and in this case a CQUAD4 corner request is ignored.

Known Error

CR 1-158333039

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Component Modes - fluid-structure, AUTOQSET - SFM 6036 or SFM 6143 If PARAM, AUTOQSET, YES is specified for a fluid-structure model then the run may fail in CMPMODE with: SYSTEM FATAL MESSAGE 6036 (XQAERR) ATTEMPT TO DIVIDE BY INTEGER ZERO or:

Description

SYSTEM FATAL MESSAGE 6143 (UPARTPR) THE SIZES OF THE INPUT MATRICES AND THE DOF SETS ARE INCOMPATIBLE. SPECIFICALLY: The number of rows in VGFS is not equal to the size of the G-set User Information: Size of input matrix and DOF sets: VGFS : Rows= 88 by Cols= 1 Set sizes: Major (G-set)= 126 Set0 (A-set)= 38 Set1 (COMP-set)= 88 Avoidance: Insert the following DMAP alter: compile phase1b alter 'if ( splitfs',''

Known Error

CR 1-158333039 dbstatus vgfs//s,n,novgfs $ if ( novgfs>0 or splitfs or fluidse>0 ) then $ compile semr3 alter 'vafs','' equivx vgfs/vafs/noaset $ if ( noaset>-1 ) UPARTN USET,Vgfs/VaFs,,,/lgset/laset//1 $

Known Error

CR 1-164877040

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

A SOL200 run with DRESP1s having both RTYPE=TOTSE and ESE fails with SFM3007/illegal input in dsad19 When a SOL200 run includes both a total strain energy response (RTYPE=TOTSE) and element strain energy responses (RTYPE=ESE) it will fail with a message like SFM 3007 illegal input to subroutine dsad19. User avoidance - don't attempt to use TOTSE and ESE in the same run.

Known Error

CR 1-175913955

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

A static aeroelastic run with many aerodynamic strips may fail with UFM7710 in MAPCTI In v2007 (MD R2), when a static aeroelastic run includes many aerodynamic stips, it can encounter the following fatal message due to improper processing of the moncncm bulk data entry

Description

*** USER FATAL MESSAGE 7701 (MAPCTI) COMPONENT ID: STRP[1], WAS NOT FOUND. PROGRAMMER INFORMATION: COMPONENT STRP[1] DOES NOT APPEAR IN THE TABLE. User Avoidance: the only reliable avoidance is to remove the moncncm requests.

Known Error

CR 1-180738247

Product

MSC / MD Nastran

Corrected Version GL Abstract

Flexible elements that reference SPOINTs instead of GRIDs causes unpredictable results

Description

A flexible element (such as a CQUAD4) that references an SPOINT can

Known Error

CR 1-180738247 produce erroneous results. Avoidance: do not use SPOINTs for flexible elements.

Known Error

CR 1-181293901

Product

MSC / MD Nastran

Corrected Version Abstract

Buckling - ESE, set - wrong output If a set is used to request output (e.g., ESE) in a buckling analysis, and the number of buckling subcases are different than the number of static subcases, then the answer (incorrect set) will be printed. An example of such a setup is shown below (1 static subcase and 2 buckling subcase)

Description

set 1 = 1,2,3,4 set 2 = 5 thru 10 $ SUBCASE 1 LOAD = 10 $ SUBCASE 10 statsub = 1 METHOD = 10 ese = 1 $ SUBCASE 20 statsub = 1 METHOD = 10 ese = 2 Avoidance: If the set option is desired, then create equal number of static and buckling subcases.

Known Error

CR 1-184621321

Product

MSC / MD Nastran

Corrected Version Abstract

SOL400 - The result of CQUADX in DBALL for Patran is incorrect.

Description

The result of CQUADX in DBALL (SCRATCH=POST) for Patran is incorrect. Use PARAM POST -1.

Known Error

CR 1-186618051

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4)

Known Error

CR 1-186618051

Abstract

SOL 200 with PCOMP having 100+ plies and PARAM DESPCH1= 1 may fail with signal 11 error in log file In v2001, if SOL 200 job with PCOMP entries having more than 100 plies and PARAM,DESPCH1,1(or 5), the job may end abruptly with a message similar to the following in the log file:

Description

Signal caught, signal=11 job aborting User signal caught, errno=0 Command exited with non-zero status 1 Avoidance: Remove the PARAM,DESPCH1 entry or set it to 4.

Known Error

CR 1-189632011

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Exterior Acoustics - SPCD, SOL 108 - SFM 6144 When enforced motion is requested in SOL 108 with exterior acoustics then the run may fail with:

Description

* ENFORCED DISPLACEMENT USING SPC / SPCD DATA *** SYSTEM FATAL MESSAGE 6144 (PARTN1PR) THE SIZES OF THE INPUT MATRICES AND PARTITIONING VECTORS ARE INCOMPATIBLE. SPECIFICALLY: The number of columns in MSH is not equal to the number of rows in the column partitioning vector VYFS User Information: Size of input matrix and partitioning vectors: MSH : Rows= 29 by Cols= 26992 VYFS : Rows= 26096 VXFS : Rows= 29 Avoidance: Insert the following DMAP alter: compile sedfreq alter 'call getpyh'(,-2) call dbstore vafse,,,,//0/0/' '/0 $ compile cforce1 alter 'UPARTN USET,VGFS'(2) call dbfetch /vafse,,,,/0/0/0/0/0 $ paraml uset//'uset'//////'e'/s,n,noeset $ if ( noeset>-1 ) equivx vafse/vyfs/-1 $ compile getpyh

Known Error

CR 1-189632011 alter 'call cforce','' call CFORCE USETd, ,yst,,Msh,,Bsh,, KSh,k4sh,,kdsh,,ol,,a1sh, cases,dynamics,dit,vgfs,vphfs,nzyg/ pyxt/ APP/APP/'enforce'/true/false/fs/fonly $

Known Error

CR 1-189635526

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

CARD "DYRELAX" error in sol700 Error: The translation of the parameters in card "DYRELAX" is wrong in MD SOL700 R3. The option of DRFCTR and DRTERM in DYRELAX card are not assigned correctly. When DRFCTR(dynmic relaxation factor) is assigned to 0.995, dynamic relaxation termination time is set to 0.995 instead that dynmic relaxation factor is set to 0.995. DRTERM (dynamic relaxation time) is dumped to scale factor. The bug was fixed in MD R4.

Known Error

CR 1-189764551

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Nonlinear Harmonic Response - UNBALNC entry, SOL SENLHARM (or SOL 128) - null loads If the UNBALNC entry is used in nonlinear harmonic response (SOL 129), then no loads are generated as indicated by:

Description

*** USER FATAL MESSAGE 4346 (FRLGA) THE DYNAMIC LOAD SET xx SELECTED BY THE DLOAD CASE CONTROL COMMAND IS NOT DEFINED IN THE BULK DATA BY RLOADi, TLOADi OR ACSRCE ENTRIES. Avoidance: Insert the following DMAP alter: ECHOOFF $ COMPILE SENLHARM NOLIST $ ALTER 'FRLG.*CASEF.*USETD','' $ FRLG CASEF,USETD,DLT,FRL,,,DITS,,APPLOD,ENFLODK,

Known Error

CR 1-189764551 ENFLODB,ENFLODM,ENFMOTN,ROTORT,UNBVECG,EQDYN,,/ PPF,,,FOL,,YPF,,,,,,/ SOLTYP/S,N,FREQY/S,N,APPF $ ENDALTER $ ECHOON $

Known Error

CR 1-189935142

Product

MSC / MD Nastran

Corrected Version Abstract

Description

*** SYSTEM FATAL MESSAGE 4276 (ENDPUT) Client running SOL111 for random analysis with MFLUID on a 135,967 grid model. Job aborted with SFM 4276 *** SYSTEM FATAL MESSAGE 4276 (ENDPUT) ERROR CODE 1305 PID= 0 The conditions that cause this are under investigation.

Known Error

CR 1-189955780

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Incorrect CREEP material conversion in SOL 600 A SOL 600 model with CREEP data may have an incorrect translation to marc: MATVP 1 TABLE 1.0 101 TABLEM1 101 It is converted to marc entry

Description

CREEP, DATA COMMENT, MATHVP 1 18, 0, 0, 0, 1.000000E+00, 5.000000E-01, 1.000000E-01, , 1, 1 which is a temperature table (18 in field 1). If MATVP table ID 101 is in field 6, then Marc input deck will have stress table (18 in field 2). It seems the order of independent parameters is different in Nastran and Marc. Fixed in 2010

Known Error

CR 1-189960851

Product

MSC / MD Nastran

Corrected Version Abstract

SOL 106 HOT2COLD, error with "ANALYSIS=MODES" in 2nd subcase (wrong answers). If a modal analysis is performed as the 2nd subcase (with the 1st subcase using "ANALYSIS=HOT2COLD") the differential stiffness (stress stiffening / follower force effects) effects are included. However according to the documentation the "ANALYSIS=HOT2COLD" subcase should only "reset" the geometry (grids), and the 2nd subcase should not include any loading history, differential stiffness, ...

Description

Reference: MSC Nsstran QRG, "ANALYSIS" Case Control option, note 8. In SOL 106, ANALYSIS=HOT2COLD allows the user to input the ‘stressed’ or deformed geometry (normal bulk data input) and ‘unload’ the structure to determine the unstressed shape. The specified load will be reversed to calculate the displacement of the ‘unloaded’ structure. This feature will also ‘reset’ the geometry to the ‘unstressed’ position for additional subcases. For example: SUBCASE 1 $ UNLOAD STRUCTURE ANALYSIS=HOT2COLD LOAD= 100 NLPARM= 100 SUBCASE 2 $ NORMAL MODES UNLOADED STRUCTURE ANALYSIS= MODES METHOD= 100 DISP=ALL ... Subcase 1 unloads the model and subcase 2 calculates the modes of the ‘undeformed’ structure; the differential stiffness and follower force effects will not be included.

AVOIDANCE: Insert a 2nd subcase that references a LOAD with a scale factor of "0.0".

Known Error

CR 1-189960851 Then run the modal analysis as the 3rd subcase.

Known Error

CR 1-190510485

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Static Analysis - SOL 101, MONITOR Command - Missing output

Description

Running SOL 101 with only a MONITOR=ALL in the Case Control without any other output requests results in no structural monitor point integrated loads output. Avoidance: add a DISPLACEMENT request in the Case Control

Known Error

CR 1-190522121

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

The HASHIN Fabric or Tape failure criteria for MATF are not properly printed in f06 file The output for the HASHIN Fabric failure criteria input for MATF in SOL 400 is printed as Tape while the Tape criteria input is printed as Fabric

Description Avoidance: No avoidance available Known Error

CR 1-190562844

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

PARAM, OPTEXIT, 7 is not honored by a Sol200 run with DDVAL entries When DDVAL is being used and the optimization converges the sensitivities are not being output using param, optexit, 7 or DSAPRT(START=LAST).

Description

Resolution: Design Sensitivity analysis is never performed following a discrete design optimization. Therefore, no sensitivity output will be produced with DSAPRT(END=LAST) when discrete optimization is performed at the end of a job. The documentation for DSAPRT is updated for 2010.

Known Error

CR 1-190565751

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4)

Known Error

CR 1-190565751

Abstract

SOL 145 flutter with K-Method and All Normal Modes Used may produce incorrect results SOL 145 flutter analysis utilizing all modes in the calculations and the K-Method may produce incorrect results.

Description

Avoidance: Set parameter LMODES and NVALUE on the FLUTTER bulk data entry to a number less than the total number of DOFs in the model

Known Error

CR 1-190933681

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

Access violation in DCMP (for auto-suport) for V2008 however job runs in V2007 Access violation in DCMP (for auto-suport) for V2008 however job runs in V2007 One possible workaround is to set sys206=4 fixed in 2010

Known Error

CR 1-190938893

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Frequency Response Analylsis - DISP(CID) and INTENSITY - UFM2170 When 'DISP(CID)' request to print CD for grid point related output is input in frequency response analysis, the following UFM2170 is printed after responses in V2007r1, V2008r1, MD R2, and MD R3.

Description

*** USER FATAL MESSAGE 2170 (PARTN2) BOTH THE ROW AND COLUMN PARTITIONING VECTORS ARE PURGED AND ONLY ONE MAY BE. Avoidance: None. But this fatal message can be safely ignored and does not afffect the displacement results. However, INTENSITY Case Control will not work properly with the CID option.

Known Error

CR 1-191279910

Product

MSC / MD Nastran

Corrected Version Abstract

Postprocessing - SOL 106 or 129, PARAM,POST,0 - missing results

Known Error Description

CR 1-191279910 In SOL 106 or 129 restart with a previously created xdb database, the new results may not be written to the xdb file. Avoidance: none.

Known Error

CR 1-191285241

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Sol700 finds an error when BCBODY and related BCGRID don't have the same ID Error: When SPOTWELD contact is used, the SLAVE refers BCGRID directly instead of BCBODY. Although the SLAVE body must refer BCBODY connecting to BCGRID, it refers BCGRID directly and skips BCBODY. For example, If a spotweld contact is defined like this

Description

BCBODY, 1, 3D, DEFORM, 3 BCGRID, 3, n1, n2, … BCBODY, 2, 3D, DEFORM, 4 BCPROP, 4, 1, 2 BCTABLE, 1, +, SLAVE, 1, +, +, , , ,SPOTWELD, +, MASTERS, 2 Then Sol700 crashes with the following error message in the d3hsp: %E *** Error MDNastran input contact ( 1) : BCGRID ( 1) does not exist In fact, it runs only when the BCBODY and the related BCGRID have the same ID: BCBODY, 3, 3D, DEFORM, 3 BCGRID, 3, n1, n2, … BCTABLE, 1, +, SLAVE, 3, +, +, , , ,SPOTWELD, +, MASTERS, 2 It was fixed in MD R4.

Known Error

CR 1-191422623

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Miscelleneous - nastran command keyword node - fatal message When an attempt is made to run the job with node= option following sample message is issued.

Description

*** USER FATAL MESSAGE (pgm: nastran, fn: main) jid=/scratch/ssp/pt1111.exp (command line[2]) This file does not exist. Avoidance: None.

Known Error

CR 1-191480951

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Increase Maximum number of Output2/Output4 files The number of files assigned by the user is limited. Depending on the type of solution, this limit is in the range of 50-75 user files.

Description The number of total allowable files, including the required Nastran files, has been raised to 125 in MD 2010 Known Error

CR 1-191688201

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Superelements and Dynamics - SEDAMP, element forces - wrong answers If the SEDAMP (instead of RSDAMP) is used for a non-superelement model then the SEDAMP is ignored in the calculation of element forces affected by damping factors G, W3, and W4.

Description

Avoidance: Insert the following DMAP alter: compile sedrcvr alter '554'(,1) if ( damping=0 ) add5 bjj1,bjjparm,,,/bjj $

Known Error

CR 1-200401004 endalter

Known Error

CR 1-201131735

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL 200 job with auxiliarymodel may require PARAM,SPARSEDR,NO SOL 200 shape optimization with auxillary model may require turning off sparse data recovery, PARAM,SPARSEDR,NO.

Description

Avoidance: Insert 'PARAM,SPARSEDR,NO' for SOL 200 shape optimization job with auxillary model

Known Error

CR 1-201279995

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Aerostatic Analysis - SPCForces, sparse data recovery, MPC, rigid elements Wrong answers In SOL 144 (or SOL 200 with ANALYSIS=SAERO), if sparse data recovery is on and there are loads applied directly (or via the aero mesh) to dependent degrees of freedom which are constrained at their independent degree of freedom, then the SPCForce results may be wrong. Avoidance: Insert the following DMAP alter:

Description compile spdr1 alter 'outprt.*vpx' equivx vpx/vpg/-1 $ endalter Or set PARAM,SPARSEDR,NO Known Error

CR 1-202440855

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

SOL 200 job with PARAM,NASPRT,n may have missing SUBCASEs of last cycle in OP2 In SOL 200 Optimization with analysis=dfreq, no results are written to OP2 for for the last cycle of the second SUBCASE if PARAM, NASPRT,n n is used and the frequency range for the first subcase is higher than the frequency range of second. For example, 100 to 150Hz. for the first SUBCASE and 50 to 100Hz for the second SUBCASE.

Known Error

CR 1-202440855 Avoidance: None.

Known Error

CR 1-202518501

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

When PARAM,CHECKOUT,YES is input, you used to get a false UWM 5276 (EQD8D).

Description

You used to get an erroneous message UWM 5276 (EQD8D) when PARAM,CHECKOUT,YES. The message falsely stated there was excessive curvature.

Known Error

CR 1-204840621

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Linear Perturbation - ANALYSIS=DFREQ, SOL 106, param,coritan,yes - SFM 6143 (UPARTPR) In SOL 106 with ANALYSIS=DFREQ and scr=no and PARAM,CORITAN,YES will fail with: *** SYSTEM FATAL MESSAGE 6143 (UPARTPR) THE SIZES OF THE INPUT MATRICES AND THE DOF SETS ARE INCOMPATIBLE. SPECIFICALLY: The number of rows in GYBJJ is not equal to the size of the N-set The number of columns in GYBJJ is not equal to the size of the N-set If PARAM,CORITAN,YES is removed the simulation runs past the 1st subcase without error, but then another fatal message is issued.

Description

*** USER FATAL MESSAGE 1126 (GNFIST) DMAP MODULE SDRX IS ATTEMPTING TO OUTPUT DATABLOCK 203 NAME = OSTR1X , WHICH ALREADY EXISTS Avoidance: Insert the following DMAP alter: compile nlstatic alter 1 file gybaa=save,ovrwrt $ compile nlkr alter 1 file gybaa=save,ovrwrt $ alter 'UPARTN USETNL2,gybjj','' IF ( NOSSET>-1 ) UPARTN USETNL2,gybnn/gybaa,,,/lnset/lfset $

Known Error

CR 1-206090939

Product

MSC / MD Nastran

Corrected Version Abstract

Ref. Manual Figure 13-7 Some Isotropic Yield Surfaces in Principal Stress Space - equation error

Description

Ref. Manual Figure 13-7 Some Isotropic Yield Surfaces in Principal Stress Space - equation error Equation:tan θ = sqrt(6) 2sin φ/sqrt(3)(3 – sin θ) should read: tan θ = sqrt(6) 2sin φ/sqrt(3)(3 – sinφ)

Known Error

CR 1-207025816

Product

MSC / MD Nastran

Corrected Version Abstract

SOl 400- The HBDY output is missing from the CQUADX and CTRIAX in thermal axi-symmetric solid SOL 400 - The HBDY output is missing from the CQUADX and CTRIAX in thermal axi-symmetric solid element

Description

The energy balance is missing from the following output 0 SUBCASE 1 STEP 1 LOAD STEP = 1.00000E+00 HEATFLOWINTOHBDY E L E M E N T S (CHBDY) ELEMENT-ID APPLIED-LOAD FREE-CONVECTION FORCED-CONVECTION RADIATION TOTAL 100001 0.000000E+00 0.000000E+00 0.000000E+00 0.000000E+00 0.000000E+00 100002 0.000000E+00 0.000000E+00 0.000000E+00 0.000000E+00 0.000000E+00

Known Error

CR 1-210724527

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

Exterior Acoustics FFT generates "FP division by zero" in Log File for a 0.0 forcing frequency The FFT for the acoustic field point mesh computations cannot be performed at 0.0 forcing frequency since division by 2PI*ffreq is required. Possible avoidance: remove the 0.0 forcing frequency.

Known Error

CR 1-210724533

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

A SOL 200 job with DRESP1=AFPWR may fail with SFM 6143 SOL 200 optimization job with DRESP1 having RTYPE=AFPWR may fail with System Fatal Message 6143. This bug was found in MDR3 but fixed in MD2010 Avodiance: None.

Known Error

CR 1-210926816

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Note about SETP being used only for EDE, EKE, and ESE is missing from QRG

Description

"SETP usage is limited to the EDE, EKE, and ESE Case Control Commands" this note is not available in QRG however is mentioned in release guide.

Known Error

CR 1-211679787

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL 129, DCMP, maxratio not honored, GRID ID =0 for warning message In a SOL 129 run, the matrix to factor diagonal may issues messages that identify the grid point ID as "0" instead of the actual ID.

GRID POINT ID DEGREE OF FREEDOM MATRIX/FACTOR DIAGONAL RATIO MATRIX DIAGONAL

Description

0 R2 1.50499E+06 2.51554E+08 0 R2 2.11867E+07 2.51370E+08 0 R2 2.14707E+07 2.51590E+08 0 R3 2.58778E+07 2.68724E+07 This is due to the fact that data blocks required for the proper identification of degrees of freedom contain data that is dynamics-oriented rather than statics-oriented in some of the solution processes in SOL 129.

Known Error

CR 1-211679787 Furthermore, PARAM,MAXRATIO may not be honored in some decompositions since they are internal to a module that does not access to the parameter. Avoidance: None known.

Known Error

CR 1-211713291

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Bead vector direction in SOL200 topography is wrong Bead vector direction in SOL200 topography is wrong if NORM = BLANK used on BEADVAR entries. The topography optimization job runs through but the generated bead is on reverse side of the PSHELL.

Description

This bug was found in MD R3 but fixed in MD2010 Avoidance. Use XD/YD/ZD on BEADVAR entries to define bead vectors.

Known Error

CR 1-211956382

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

sol 101 - uim 5274 (LAPEIGD) - heatstat,yes

Description

When doing heat and structural analysis in one 101 run the program is mistakenly trying to do residual vector damping calculation.

Known Error

CR 1-211956706

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

sol 400 - MAIN: "Access violation" (C0000005) exception encountered.

Description

For some large jobs on Windows 32 with low memory request, the job may fail in DECOMP when using Metis reordering. Several error messages may appear. The error message may or may not say it was an error in Metis. In each case there would be an access violation due to an allocation error. Errors may look like this: *** SYSTEM FATAL MESSAGE 6916 (MREORDR) MALLOC FAILED INSIDE EXTREME. USER ACTION: DECREASE THE MEMORY GIVEN TO THE JOB IN ORDER

Known Error

CR 1-211956706 TO INCREASE THE MEMORY AVAILABLE FOR MALLOC OR USE METIS OR GRID BASED MMD REORDERING by RE-SUBMITTING THE JOB WITH ONE OF THE FOLLOWING VALUES FOR SYSTEM(206): SYSTEM(206)=1 (GRID BASED MMD) SYSTEM(206)=8 (GRID BASED METIS) OR SYSTEM(206)=9 (SELECTS BEST OF THE TWO ABOVE) 0FATAL ERROR

MAIN: "Access violation" (C0000005) exception encountered. MAIN: For reference, A(MAINAL) = 4011B2, A(/SYSTEM/) = 3605C80 MAIN: A(/XNSTRN/) = 7940000 MAIN: Exception occurred at address 7C911689. MAIN: Program attempted to access data at location 00000001.

Metis Error: ***Memory allocation failed for Allocate2WayPartitionMemory: rdata. Requested size: 1368 bytes Avoidance: Change system cell 206 to a different method. Known Error

CR 1-211981733

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL200 run with scr=no may result in a fatal error MESSAGE 1126 (GNFIST) SOL200 run with scr=no may result in a fatal error MESSAGE 1126 (GNFIST) *** USER FATAL MESSAGE 1126 (GNFIST) DMAP MODULE TA1 IS ATTEMPTING TO OUTPUT DATABLOCK 203 NAME = GEI , WHICH ALREADY EXISTS. USER ACTION: DELETE THE DATABLOCK, OR USE FILE GEI=OVRWRT This bug was found in V2007 /MDR3 and fixed in MD2010

Description

Avoidance Run with scr=yes or include the following dmap alter for Versions 2008 and earlier

compile phase1a alter 'file' file gei=ovrwrt $

Known Error

CR 1-212013461

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Linear Perturbation Analysis - SOL 106, ANALYSIS=MODES, scr=no - wrong answers In SOL 106 with scr=no, if nonlinear subcases appear after ANALYSIS=MODES subsase then the nonlinear displacements will be null. Avoidance: Submit analysis with the "scratch=yes" option OR insert the following DMAP alter:

Description

compile nlstatic alter 'case.*caset' type parm,,char8,n,oanal $ oanal=anal $ alter 'scid' if ( oanalanal ) then $ delete /oefnlxx,oesnlxx,oesnlyy,, $ dbdelete datablk=(ugni,qgni,qmgni,pgni,cvect) , where(wildcard)$ endif $

Known Error

CR 1-212138881

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

MATD098 can not apply for SOLID ELEMENT Error: For MD SOL700 R3, PSOLID+MATD098 combination generate error message in SOL700. psolid (= 3) references wrong material type (= 98). It was fixed in MD R4

Known Error

CR 1-212160225

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL111 job with mcfraction fails with Floating Point Trap - 32 bit Modal Contributioon Fraction computations involving very small values may fail with a floating point operation trap error on 32 bit implementations. This failure has been noticed in 2008 on linux systems.

Description Possible avoidance: do not request MCFRACTION output for Degrees of Freedom exhibiting very small modal responses.

Known Error

CR 1-212160225 Fixed in 2010

Known Error

CR 1-212194344

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

A SOL 145 run does not produce AEROF results with the AEROF=n request

Description

AEROF Case Control Command is not supported in SOL 145

Known Error

CR 1-212465241

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL 200 with eigenvector sensitivity and constraints in upstream SE may fail in DOM10 module SOl 200 job may fail in DOM10 module if following conditions are met

Description

1. eigenvector constraints in upstream SE 2. modes involved in eigenvector sensitivity are not referenced in residual SE Avodiance: make sure all modes involved are referenced in residual

Known Error

CR 1-213147195

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Data Recovery - MAXMIN, CTRIA3, CQUAD4 - missing output

Description

MAXMIN Case Control command does not recognize item names TMAX1 and TMAX2 for CQUAD4 and CTRIA3. Avoidance: Use SMAX1 and SMAX2.

Known Error

CR 1-215419593

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Misleading User Fatal Message 6482 for a SOL200 run with a Analysis=MODES subcase

Description

In v2001, if the user constrains an element/grid response in an ANALYSIS=MODES subcase and neglects to identify the mode number in the ATTB field of the DRESP1 entry, this will result in a misleading message such as:

Known Error

CR 1-215419593 *** USER FATAL MESSAGE 6482 (DOPR3R) FOR SUBCASE 2, THE ANALYSIS TYPE IS MODES BUT THE DESSUB COMMAND REFERENCES AN INCOMPATIBLE DRESP1 ENTRY WITH RID = 17 AND RTYPE = STRESS . The problem is not that the analyis type is incompatible, but that it requirs specifying the mode in the attb field of the DRESP1 entry. User Avoidance: Specify the mode number in the ATTB field of the DRESP1 entry when design an eigenvector response.

Known Error

CR 1-216054731

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

Unique PIDs required for SOL600 models A model with the following PID & MID combinations will result in a marc.dat file with all elements using MID 1. CQUAD --> PSHELL #1 --> MAT1 #1 CTETRA --> PSOLID #1 --> MAT1 & MATS1 #2 The Nastran model must be created like this: CQUAD --> PSHELL #1 --> MAT1 #1 CTETRA --> PSOLID #2 --> MAT1 & MATS1 #2

Known Error

CR 1-216190171

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

Dynamic Analysis with Preload - BCONTACT, STATSUB - wrong answers or various fatal messages The BCONTACT Case Control command for general (unglued) contact is ignored in a static preload subcase (see STATSUB command) resulting in either wrong answers and/or various fatal/warning messages. Avoidance: Remove the request for unglued contact.

Known Error

CR 1-217253508

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Acoustic Analysis - CQUAD4 and CELASi in SOL109 sloshing - UFM 2170

Known Error

CR 1-217253508 (PARTN2) Acoustic analysis with sloshing in SOL 109 may produce the following message: *** USER FATAL MESSAGE 2170 (PARTN2) BOTH THE ROW AND COLUMN PARTITIONING VECTORS ARE PURGED AND ONLY ONE MAY BE. Avoidance: Run with SOL 112 or insert the following DMAP alter:

Description

compile sedtran alter 'call fdrmgen','' call fdrmgen uset,,caseg,usetd,gm,got,goq,, MSF,mdsf,M2SF,m2dsf,BSF,bdsf,B2SF,b2dsf, KSF,K4SF,k4dsf,K2SF,k2dsf,asf,adsf, MMG,M2MG,BMG,B2MG,KMG,K4MG,K2MG,kdmg,kdsf,kddsf, MSS,M2ss,BSS,B2ss,KSS,K4Ss,k2ss,kdss,yg, ects,bgpdts,sils,xycdb,matpool,pg,dynamics,casecc, slist,emap,maps,,,,,mmcdb,oint,pelsets, pmyg,pbyg,pkyg,ajp,day,nzyg,goy,,,gpect,edts,,vgfs, dits,,,thetam,axic/ ,rpd,rgs,rgm,,,, msf1,bsf1,ksf1,mss1,bss1,kss1, MMG1,BMG1,KMG1,,,, vspcg,vmpcg,v01p,v01dr,vpg,vgdr,,,rpy,,/ app/app/soltyp/false/false/nooset/noa/nomset/ s,dompcf/s,dospcf/nosset/noue/false/false/false/false/ rsonly/' '/s,spdrs/s,spdrm/pexist/false/ $ for v2008 s,spdr/adptindx/true/false/fs/fonly/0 $ $ for v2007 $ S,SPDR/ADPTINDX/TRUE/FALSE/FS/FONLY $

Known Error

CR 1-219428708

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

NSML1 and PBEAML may give incorrect mass

Description

If an NSML1 refers to a PBEAML entry the resulting nonstructural mass is incorrect.

Known Error

CR 1-219452535

Product

MSC / MD Nastran

Corrected Version

Known Error

CR 1-219452535

Abstract

Linear Perturbation Analysis - Missing results in database if multiple NLSTAT and MTRAN/MFREQ This a duplicate CR report. The problem happens when both nonlinear and linear analyses run together in a single job. The cause is that the OP2 file is rewound every time PHASE0 is called for a new group of analysis types.

Description

No error message is issued for this matter. Avoidance: Run regular linear analyses in a job and nonlinear analyses+linear perturbations in another one. Note: This error is only in OP2 output file.

Known Error

CR 1-219452551

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract Description

Arbitrary beam properties via PBRSECT/PBMSECT may be incorrect Arbitrary beam properties via PBRSECT/PBMSECT may not be correct due to aggressive intersection detection logic. Avodiance : if possible, avoid using short segment with thick thickness.

Known Error

CR 1-219488629

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

BCPARA should support SOL103 also. In MD Nastran R3, BCPARA does not support SOL103. Avoidance: Define ERROR (Distance Tolerance) for each body

Description

In MD Nastran 2010, We support BCPARA in ALL solutions, including SOL 111, for both 3D general contact and permanently glued contact

BCPARA or similar function is needed for SOL103 and others. Known Error

CR 1-219561485

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4)

Known Error

CR 1-219561485

Abstract

MPF, bad panel definition produces UFM 2170 in PARTN2 When a panel definition contains only nonexisting grid points, the matrix partitioning module issues UFM 2170 and Nastran stops after the modal phase.

Description

Description

DMAP Avoidance: compile pfact $ alter 'TYPE,PARM,,RS,N,DENMIN=0.90','' $ TYPE,PARM,,RS,N,DENROW,DENCOL,DENMIN=0.90 $ alter 'IPANEL = IPANEL' $ DENCOL = 0.0 $ DENROW = 0.0 $ alter 'IF ( DENCOL\ 1. In SOL 101 general contact, Case Control, NLPARM, used in the 1st SUBCASE is also used in the 2nd SUBCASE; 2. There is no error message issued. The solutions are wrong. fixed in 2010

Known Error

CR 1-219784024

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

MD R3b Nastran touch contact w BCTABLE 0 and multiple subcases overrides MASTER-SLAVE from other BCT In MD Nastran a BCONTACT prior to all other Subcases (BCONTACT=0) was overwriting local Subcase BCONTACT/BCTABLE settings. In MD Nastran 2010 this has been resolved.

Description

Additionally, in previous versions if say a BOUTPUT(SORT1,REAL)=ALL was called in the first Subcase but then a ‘PLOT’ request was made, BOUTPUT(PLOT,SORT1,REAL)=ALL, the non-PLOT would hold for all Subcases. This was an error not covered by this CR but also resolved in this in this version of Nastran. This was resolved under CR 1-226741991

Known Error

CR 1-219907221

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Acoustics - DMP, SOL 108 - ACPOWER, INTENSITY, and ACFPMRESULT Missing output

Description

If dmp>1 is specified in SOL 108, then the resulting output from PFPANEL,

Known Error

CR 1-219907221 PFMODE, PFGRID, ACPOWER, INTENSITY, and ACFPMRESULT from the slaves will be missing. Avoidance: Insert the following DMAP alter which also fixes similar errors for PF* and ACPOWER results: compile sedfreq alter 'call super3' DBSTATUS AFPMLIST//S,N,NOAFPM $ PARAML CASEf//'DTI'/-1/613//S,N,INTENSET $ PARAML CASEf//'DTI'/-1/416//S,N,ACPOWSET $ paraml casef//'dti'/-1/512//s,n,pfmodes $ paraml casef//'dti'/-1/519//s,n,pfmodef $ paraml casef//'dti'/-1/528//s,n,pfpanel $ paraml casef//'dti'/-1/535//s,n,pfgrid $ if ( nproc>1 and nfreqt>1 ) then $ if ( pfmodes=-1 or pfmodef=-1 or pfpanel=-1 or pfgrid=-1 ) call disfreq fol,udf,pdf,,,ypf,ypf1/ udf0,pdf0,,,ypf0,ypf10/ nfreqt/nproc/procid/false $ if ( noafpm=1 or intenset1 ) then $ CALL PFACT CASEF ,BGPDTS ,USET ,USETD ,SILS , GOT ,GOQ ,GM , , , ,UDF ,FOLt ,PDF ,VGFS , ,CKDD ,CBDD ,CMDD ,ABE , AGG , ,YPF10 ,RPY ,YPF0 / SMPF ,SMPFD ,OSMPF1 ,AFMPF ,AFMPFD , OAFMPF1 ,ASMPF ,ASMPFD ,OASMPF1 ,APMPF , APMPFD ,OAPMPF1 ,APPF ,APPFD ,OAPPF1 , AGPF ,AGPFD ,OAGPF1 / NOASET /NOOSET /NOQSET /NOTSET /NOMSET / NOA /NOUE /APP /SOLTYP /FS / FONLY $ IF ( intensetnleft ) then $ istart= (procid-1)*nf + nleft + 1 $ else $ istart= (procid-1)*nf + procid $ endif $ nzero= nfreqt - ifreq + 1 $ matgen ,/expand/4/1/nrow//ifreq/nzero/istart $ $ expand to complete freq/load list merge ,,,udf,,expand,/udfe/1 $ merge ,,,pdf,,expand,/pdfe/1 $ merge ,,,ppf,,expand,/ppfe/1 $ merge ,,,qsgf,,expand,/qsgfe/1 $ merge ,,,qmgf,,expand,/qmgfe/1 $ merge ,,,ypf,,expand,/ypfe/1 $ $ weave on master DISUTIL udfe,,,/udf0///-8 $ DISUTIL pdfe,,,/pdf0///-8 $ iproc=2 $ do while ( iproc1 if ( scatter ) then $ $ re-broadcast to all slaves DISUTIL udf0,,,/udf2///3 $ DISUTIL pdf0,,,/pdf2///3 $ DISUTIL ppf0,,,/ppf2///3 $ DISUTIL qsgf0,,,/qsgf2///3 $ DISUTIL qmgf0,,,/qmgf2///3 $ DISUTIL ypf0,,,/ypf2///3 $ if ( procid>1 ) then $ equivx udf2/udf0/-1 $ equivx pdf2/pdf0/-1 $ equivx ppf2/ppf0/-1 $ equivx qsgf2/qsgf0/-1 $ equivx qmgf2/qmgf0/-1 $ equivx ypf2/ypf0/-1 $ endif $ procid>1 endif $ return $ end $ disfreq

Known Error

CR 1-220425731

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Error with BCONTACT=BCBOX

Description

A model with BCBOX to define contact body may fail with the following error

Known Error

CR 1-220425731 message in the log file: forrtl: severe (64): input conversion error, unit -5, file Internal Formatted Read This problem was fixed for the 2010.1 (MDR4) release.

Known Error

CR 1-220643571

Product

MSC / MD Nastran

Corrected Version Abstract

EPOINT in SOL400 with Lagrange Multipliers can cause bad sort of LM GRIDs SOL 400 - EPOINT should not be used with lagrange Multiplier - incorrect solution may be obtained

Description

The situation where lagrange multiplier is used is when you have contact in the problem. Avoidance: repalce EPOINT by GRID

Known Error

CR 1-220643741

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

ACMS - Special DECOMP for INVLAN subDMAP can produce wrong answers and an invalid sturm count The special INVLAN decomp can produce wrong answers. The avoidance is to set param,mdlgdef,99999999

Description

There error does not always occur, but there is no way to tell apriori based on the model characteristics which models will produce the error. A symptom of the error is a Sturm count error when READ is called from INVLAN. This error is corrected in MD R4/Version 2009.0.0. A correction for MSC.Nastran 2007.0.0 for Linux x8664 is also available on the Product Update Site at: http://www.mscsoftware.com/software_updates/ The build date of this updated executable is July 10, 2009.

Known Error

CR 1-220681761

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Nonlinear Analysis - EPOINT in SOL 400 - wrong results

Known Error Description

CR 1-220681761 If EPOINT entries are present in a SOL 400 nonlinear static analysis then the results will be wrong. Avoidance: None.

Known Error

CR 1-220732801

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL 400 fails to converge using CASI solver when EPOINT is present

Description

SOL 400 may fail to converge using the CASI element-based solver if there are EPOINTs present in the input. There is no known avoidance. Fixed in 2010

Known Error

CR 1-220930902

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

A job with with NINC(NLPARM) greater than 1 in combination with Solid Composite will stop A Sol 400 job with Solid Composite elements will stop when the NINC of the NLPARM card is greater than 1. In this specific example, NINC is set to 10. *** SYSTEM FATAL MESSAGE 3003 (NLSOLV) ATTEMPT TO READ PAST THE END OF A LOGICAL RECORD IN DATA BLOCK MRELM (FILE 253) IN SUBROUTINE evecad 0FATAL ERROR Avoidance: No avoidance available

Known Error

CR 1-221252824

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

The printout for MONDSP1's CP and CD data in f06 is incorrect and incomplete in SOL 101

Description

The MONDSP1 bulk data entry allows a CP and CD field for coordinate system identification and usage in the results when running SOL 101. However, the printed output in the f06 file only outputs the CP cooridnate system id and labels it ICID. The CD coordinate system id is not provided in the table of information for the structural monitor point displacements table

Known Error

CR 1-221252824 in the f06. Version 2005r3, 2007r1 and 2008r1 exhibit this same error.

Avoidance: Use the MONDSP1 input bulk data entry to determine the CD coordinate system. SOL 144 in version MDR4 Nastran has the correct labeling information. Known Error

CR 1-221342021

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

The stress output for assumed strain CHEXA elements (solid shell) is incorrect A Sol 400 job with assumed strain CHEXA elements (a.k.a. solid shell element), the stress output is incorrect. For a model that should show stress variation through the element thickness, but the stress output is constant. Avoidance: No avoidance available

Known Error

CR 1-222985071

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

DMAP, External superelements - OUTPUT4, INPUTT4, EXTSEOUT(MATOP4) UWM 6445 Op4 files created with sparse (negative IUNIT option on OUTPUT4 module call) and neutral or ASCII (FORMATTED option on ASSIGN FMS statement) options using OUTPUT4 module are not readable with INPUTT4. This can occur for external superelements created with MATOP4 option on EXTSEOUT Case Control command. Avoidance: Do not use sparse option on OUTPUT4 module.

Known Error

CR 1-223406150

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

PFMODE, SOL 112, no output

Description

No Modal Participation Factor output is generated by the PFMODE case control

Known Error

CR 1-223406150 request for modal transient SOL 112. Avoidance : Use MCFRACTION.

Known Error

CR 1-223522069

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL112 - FILTER of MCFRACTION - doesn't filter correctly The FILTER in MCFRACTION doesn't filter correctly in SOL112.

Description

Avoidance : None. Fixed in 2010

Known Error

CR 1-223579091

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Error message when shell element form 25, 26 or 27 is used Error: In PSHELLD card, ELFORM=25,26 and 27 (only for testing) do not work correctly. Bug discovered for shell formulation options 25, 26 or 27. A default value was not set properly in the code. There is no work-around, except to choose another shell formulation option. (6/10/09)

Description *** Error element ID 2 has invalid connectivity. Try decouple thickness degrees of freedom between elements with thickness stretch on *SECTION_SHELL. Avoidance:Pleas use other element formulations. Known Error

CR 1-224542238

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Campbell Diagrams : USER FATAL MESSAGE 2170 The request for Campbell Diagrams may cause USER FATAL MESSAGE 2170. Avoidance: Insert the folllowing DMAP alter:

Description

COMPILE POSTCAMP ALTER 'VB1'(,1),'NFPREB' $ $ DBSTATUS VB1//S,N,STATVB1 $ IF (STATVB1 > 0) THEN $ PARTN BNRF,,VB1/BNRFNEW,,,/1 $

Known Error

CR 1-224542238 $ PARTN VFCUR,,VB1/VFCURB,,,/1 $ EQUIVX VFCURB/VFCUR/-1$ $ PARTN UDCUR,VB1,/UCB,,,/1 $ EQUIVX UCB/UDCUR/-1 $ $ ELSE $ EQUIVX BNRF/BNRFNEW/-1 $ ENDIF $ STATVB1 > 0 endalter

Known Error

CR 1-225557065

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

FATAL 2170 PARTN2 when Acoustics added to Rotordynamics SYNC run Sol 108 If acoustics and rotordynamics are both present in a model in SOL 108, the model might fail in ASSEMGMA with UFM 2170 due to the partition vector not existing. Avoidance: Insert the following DMAP alter to your input file:

Description

compile assemgma alter 'DBSTATUS.*M2DD' DBSTATUS VSDFD//S,N,NOVSDFD $ alter 'PARTN.*M2DD'(,-1) IF( NOVSDFD1 )THEN $ EQUIVX m2DD/m2DD1/-1 $ ELSE $ alter 'MERGE.*M2SS' endif $ alter 'PARTN.*B2DD'(,-1) IF( NOVSDFD1 )THEN $ EQUIVX b2DD/b2DD1/-1 $ ELSE $ alter 'MERGE.*B2SS' endif $ alter 'PARTN.*K2DD'(,-1) IF( NOVSDFD1 )THEN $ EQUIVX k2DD/k2DD1/-1 $ ELSE $ alter 'MERGE.*K2SS' endif $

Known Error

CR 1-225560475

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Wrong responses when Acoustics added to Rotordynamics SYNC run If the fluid uses the symmetric formulation incorrect answers might result when acoustics is added to rotordynamics SYNC run in Sols 108 or 111. This occurs if the nominal damping matrix is symmetric and the gyroscopic terms are added to the damping matrices. The resulting (frequency-dependent) damping matrix is incorrectly flagged as symmetric, causing the program to use the symmetric solver, rather than the unsymmetric solver. Avoidances:

Description

1) set PARAM,ACSYM,NO in your input (forces the unsymmetric fluid formulation) or 2) insert the following alter in your file (correctly sets the matrix trailer for the combined damping matrix) compile freqrs, list alter 'PARAML CBDD'(,1) PARAML CBDDF1//'TRAILER'/3/S,N,FORMf//S,N,NOCBDDf $ if(nocbddf -1)form = formf $ $ alter 'IF ( NOCKDD=-1 )' PARAML CkDDF1//'TRAILER'/3/S,N,FORMf//S,N,NOCkDDf $ if(nockddf -1)form = formf $

Known Error

CR 1-225561603

Product

MSC / MD Nastran

Corrected Version Abstract

Unable to create XYPLOT for random with multiple subcases When multiple subcases are present for random analyis and XYPLOT is requested, the following messages may occur:

Description

*** USER WARNING MESSAGE 6914 (RAND5) DATA OF RESPONSE, STRE, FOR GRID/ELEMENT ID, 101001, IS NOT FOUND. THE XYPLOT REQUEST OF PSDF/AUTO IS IGNORED. *** USER WARNING MESSAGE 979 (XYTRAN) AN XY-OUTPUT REQUEST FOR POINT OR ELEMENT ID 130002 -FORC- CURVE IS BEING PASSED OVER. THE ID COULD NOT BE FOUND IN DATA BLOCK 102

Known Error

CR 1-226501964

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Documentation - Quick Reference Guide for CBEAM, CBAR, PBESECT and PBRSECT

Description

Under the CBEAM and CBAR descriptions in the MDR3 (V2008 and earlier) Quick Reference Guide, there is no remark about PID being able to reference a PBESECT entry on the CBEAM entry and a PBRSECT on the CBAR entry.

Known Error

CR 1-226628886

Product

MSC / MD Nastran

Corrected Version Abstract

The GPFORCE output is ZERO for deck with Lagrange rigid elements and multiple steps in SOL 400. In a SOL 400 run with these conditions: 1) multiple STEPs within a SUBCASE 2) RIGID=LAGRANGE is defined 3) a STEP with ANALYSIS=STATIC or ANALYSIS=LNSTATIC Then the GPFORCE output for rigid elements will be zero

Description

Note that if the static case is in a SUBCASE w/o multiple steps, the GPFORCE output will be correct. Two workarounds exist: 1) if the problem is small displacement, use RIGID=LINEAR 2) add the ESE data recovery request

Known Error

CR 1-226741991

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

CR1-226741991: BOUTPUT(PLOT) always prints out contact status information in F06 in SOL 101 and 400 In MDr3.1 and earlier, when runnig the gerneral contact analysis in SOL 101 and 400, the contact status information is always printed out in the F06 even if BOUTPUT(PLOT) is applied. Avoidance: No avoidance available.

Known Error

CR 1-226752015

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4)

Known Error

CR 1-226752015

Abstract

Rayleigh damping in RSPINR with CLAN modal extraction When Rayleigh damping is added in the RSPINR card, it is possible that Nastran will extract modes with null frequency even the imaginary part of the eigenvalue is greater than 0.

Description

For rotodynamic jobs, Hessenberg method is believed to produce more accurate numeric results than Lanczos method. However, the user should check for singularities in the mass matrix with an dmap alter to ensure numeric accuracy of the Hessenberg method. Contact MSC Support for more info (fixed in MD 2010) avoidance: set sys108=8192 on the command line to turn off symmetric processing.

Known Error

CR 1-226802212

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Remark 6 of the MSC.Nastran 2008 QRG MFLUID description should include CTRIAR, CQUADR MSC.Nastran 2008 QRG, the description of MFLUID bulk data entry, remark 6 are as follows,

Description

6. The current list of elements that may be placed in ELIST1 and ELIST2 include CTRIA3 and CQUAD4. It should include CTRIAR and CQUADR as well.

Known Error

CR 1-226898705

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

tcheck and tdmin for a topology optimization job are not functioning with the Weight objective When a topology optimization job defines the structural weight response as the objective, checkboard and minimum member size control are not functioning.

This was not a bug for MDR3 but an enhancement. In MD2010, we have

Known Error

CR 1-226898705 TCHECK=2 that works for this case Avoidance: Don't use wegith as objective. Otherwise, no avoidance

Known Error

CR 1-226938643

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Virtual Mass - PARAM,VMOPT,2 and MEFFMASS command - inefficient An inefficiency has been introduced for models with MFLUID, VMOPT=2 and a request for MEFFMASS. For version 2005 there was one DECOMP of the CEE matrix for MFLUID. For version MDR3 there are two DECOMPs of the CEE matrix for MFLUID. This inefficiency is apparent for models with many elements in the ELIST. Avoidance: Remove the MEFFMAS command or insert the following DMAP alter:

Description compile mgen2a alter 'uee,lee' call dbstore lee,uee,,,//0/0/' '/0 $ compile mgen1 alter 'lee,uee'(,-3) call dbfetch /lee,uee,,,/0/0/0/0/0 $ dbstatus lee//s,n,nolee $ if ( nolee8, ACMS - poor message If dmp>8 on nastran command with DOMAINSOLVER ACMS, then SFM 4276 will be issued.

Known Error

CR 1-251312865 Avoidance: None.

Known Error

CR 1-251542416

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

PCOMPLS Remark 7 - ASTN can be +1 or -1 In MDR3, the PCOMPLS entry: The QRG remark 7 has a figure with a note: * Only DIRECT=1 is allowed. The remark needs to be updated with * Only DIRECT=1 or -1 are allowed

Known Error

CR 1-251689018

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SEELT card with THRU option

Description

If we use the SEELT card and we define the element list with the THRU option, then the following warning appears : *** USER WARNING MESSAGE 6799 (SEP1C) QUAD4 ELEMENT 2 IS REFERENCED ON MORE THAN ONE SEELT ENTRY. USERS INFORMATION: SEE SEELT ENTRIES FOR SUPERELEMENTS 1 AND 1.

Known Error

CR 1-251814171

Product

MSC / MD Nastran

Corrected Version Abstract

Buckling and Superelements - SEDR - Extra output

Description

In SOL 105, when SEDR is used to request data recovery for the residual structure only, displacements are still printed for upstream superelements for the first subcase. Avoidance: Use the DISP(PLOT) to suppress the static displacement printout.

Known Error

CR 1-251837917

Product

MSC / MD Nastran

Corrected Version Abstract

Transient Heat Transfer - SOL 159 - excessive CPU

Description

The reordering method in SOL 159 is deactivated which may cause excessive run times.

Known Error

CR 1-251837917 Avoidance: Insert the following DMAP alter: compile nltran alter 'putsys(10', '' $

Known Error

CR 1-251921531

Product

MSC / MD Nastran

Corrected Version Abstract Description

Linear perturbation analysis - wrong value for OUNIT2 in MFREQ STEP In linear perturbation analysis in SOL 400, PARAM,OUNIT2 is ignored in all but the first STEP. Avoidance: None.

Known Error

CR 1-252010831

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL 200 - Flag responses that violate constraints

Description

In response to a customer request, Design Response output in SOL 200 controlled by DOPTPRM parameter p2=8 has been augmented to flag active and violated constrains.

Known Error

CR 1-252161241

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

SOL600 SPC is not changed with subcase

Description

SPC's are not always changed properly in Marc input file when they differ between load cases. This is a random error with some models working others not working prior to the fix. There is no workaround for models that did not work.

Known Error

CR 1-252285811

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

System Fatal Message 7340 (LNNRIGL)-Eigen Value calculation of presetressed job with Lanczos method

Description

The following System Fatal Message is occuring in specific type of test

Known Error

CR 1-252285811 cases: *** SYSTEM FATAL MESSAGE 7340 (LNNRIGL) UNKNOWN INTERNAL ERROR OCCURRED.

1 – A job with non-linear contact analysis in SUBCASE 1 and Frequency Response (MFREQ) in SUBCASE 2 cannot calculate eigenvalues using LANCZOS method 2 – The same job without preload run successfully 3 – Looking at KXX and MXX (input to READ) they seems to be the same in the two run 4 – Using either of the methods: SINV,INV,GIV,MGIV,HOU,MHOU, the job seems to work properly The error is occurring in the test decks which have ALL THE FOLLOWING: 1. Contact problem with NON-GLUING contact 2. SUBCASE 1 has NLSTAT (or NLSTAT with Liner Perturbation) 3. SUBCASE 2 is linear analysis - MFREQ (or MODES) using LANCZOS method Known Error

CR 1-252308941

Product

MSC / MD Nastran

Corrected Version Abstract

Glued Contact Analysis - SOL 103 restart into SOL 111 - wrong answers If a SOL 103 analysis uses glued contact and the database is used in a dynamic analysis restart (SOL 111 for example), then the glued contact will be ignored in the restart. The modes will be re-calculated on the structure with no contact present. Avoidance: Use the following DMAP (MD R3) to avoid the error. The same error is present in MD 2010, but the DMAP may need to be ported.

Description

ECHOOFF $ COMPILE IFPL NOLIST $ ALTER 357 $ save a copy before RESTART squishes it EQUIVX ACTNOD/ACTNODZ/-1 $ ALTER 372 $ $ restore ACTNOD EQUIVX ACTNODZ/ACTNOD/-1 $ ENDALTER $ $ COMPILE PHASE0 NOLIST $ ALTER 1480 $ ELSE $

Known Error

CR 1-252308941 IF ( RSONLY ) THEN $ EQUIVX ACTNODX/ACTNODS/-1 $ ELSE $ GP1 GEOM1S,GEOM2S,,GDNTAB,MEDGE,SGPDTS,DYNAMICS,, ACTNOD/ GPLS,EQEXINS,GPDTS,CSTMS,BGPDTS,SILS,VGFS,,, ACTNODS/ S,N,LUSETS/0/0/////SEID $ ENDIF $ ENDALTER $ ECHOON $

Known Error

CR 1-252577903

Product

MSC / MD Nastran

Corrected Version Abstract

Description

External Superelements - PARAM,AUTOQSET and EXTSEOUT - UWM 2053 in GP4 When EXTSEOUT and PARAM,AUTOQSET.YES are specified then UWM 2053 may be issued from GP4 module. The message is benign. Aviodance: None

Known Error

CR 1-252776589

Product

MSC / MD Nastran

Corrected Version Abstract

Upstream Data Recovery - multiple subcases even when SEDR=no for nonlinear run and fatal is issued For an external superement run, the data recovery for the upstream superelements may be executed even though SEDR specifies the residual only.

Description

Some models may also terminate with the following error: *** SYSTEM FATAL MESSAGE 5423 (MPYAD1) ATTEMPT TO MULTIPLY INCOMPATIBLE MATRICES FILE# COLS ROWS FORM TYPE NZWD DENS TRAILER FOR MUG1 IS 101 410 420 2 2 2 24 TRAILER FOR ULS1 IS 102 7 410 2 2 820 10000 TRAILER FOR MUG1O IS 103 1 420 2200

Known Error

CR 1-252776589 This is under investigation.

Known Error

CR 1-252890431

Product

MSC / MD Nastran

Corrected Version Abstract

Multistep nonlinear analysis (SOL 400) with PLOAD, PLOAD2, PLOAD4 and follower force is unsupported Multistep nonlinear analysis (SOL 400) with PLOAD, PLOAD2, PLOAD4 and follower force is unsupported and will result in the following message:

Description

*** SYSTEM WARNING MESSAGE 4619 (TA0NL003) PLOAD, PLOAD2 AND PLOAD4 WITH FOLLOWER FORCE ARE UNSUPPORTED IN MULTI-STEP ANALYSIS EXCEPT WHEN THEY ARE REFERENCED IN THE LAST STEP ONLY Avoidance: No avoidance available

Known Error

CR 1-253035698

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

Superelements - PARAM,EXTDROUT,DMIGDB or DMIGOP2 - various fatals, wrong answers, large output files When using PARAM,EXTDROUT,DMIGOP2 or DMIGDB and the solution matrix (UL) is square then the solution will be improperly processed in the PARAM,EXTDR,YES resulting is various problems depending on the solution sequence: fatal errors oversized results files, or wrong answers. The UL matrix is square when the number of solutions is the same as the number of a-set degreesof-freedom.

Avoidance: Insert the following DMAP alter: compile extdrout alter 'mpyad.*intext,ulg' modtrl extdb////2 $ Known Error

CR 1-253109301

Product

MSC / MD Nastran

Known Error

CR 1-253109301

Corrected Version 2010.1.0 (MD R4) Abstract

Convergence failure of 360 degree rigid rotation tests for SOL 400 before MDR4 Before 2010, the solution may diverges if the following conditions are met:

Description

1. SOL 400. 2. The model has large rigid body rotation equal to or larger than 360 degrees. In this case, the solution may diverge near 360 degrees. For MD 2010, the defect has been fixed. Now the solution converges at or larger than 360 degrees.

Known Error

CR 1-253109313

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

In SOL 400, a model has large rotation larger than 180 degrees may diverges before 2010 Before 2010, a model may diverges if the following condition are met: 1. SOL 400. 2. The model has large rotaion equal to larger than 180 degrees.

Description In this case, the solution may diverges. For 2010, the defect has been fixed. Now the solution converges at or larger than 180 degrees. Known Error

CR 1-253136311

Product

MSC / MD Nastran

Corrected Version Abstract

SOL 400 transient thermal (ANALYSIS = HTRAN) with SPOINTs, UFM 2079 SOL 400 transient thermal (ANALYSIS = HTRAN) using TEMPBC option , UFM 2079

Description The TEMPBC option is not supported in SOL 400 , one needs to use SPCD and SPC1 bulk dat entries as shown in the QRG under TEMPBC remark 9. Known Error

CR 1-253159641

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4)

Known Error

CR 1-253159641

Abstract

Several bugs in Dytran-to-SOL700 Translator Version 0.5.1 In using Dytran-to-SOL700 Translator (Version 0.5.1, Sep. 7, 2009),several different bugs were found in the translated file: 1) Floating point fields entered as an integer on the Dytran input deck, are not translated on the CORD2R entry. SOL700 does not accept integers on float fields. Workaround: add decimal point manually. Solved in next version. 2) DYMAT24 not translated, however SOL700 does not support DYMAT24. Workarround: replace by MATD024 manually. Solved in next version.

Description

3) SET1 entry with "THRU" not properly translated. Workaround: reformat the SET1 entry manually with THRU only appearing in columns 4-8 (first line) resp. 3-8 (continuation lines) Solved in next version. 4) PARAM,CONTACT,THICK not supported by SOL700. Workaraound: remove this entry from the input deck. Solved in next version. 5) translated FAILMPS entry contains in integer on field 4 where a floating point value is expected. Workaraound: add decimal point manually. Solved in next version. 6) CFACE cards not translated to BCSEG completely. Workaround: Add missing information on BCSEG entries manually. Solved in next release.

Known Error

CR 1-253163862

Product

MSC / MD Nastran

Corrected Version Abstract

FBA (Frequency Based Assembly) job results are not available on the XDB FBA (Frequency Based Assembly) job results are not available on the XDB.

Description Avoidance: use PARAM,POST,-1 to get OP2 file results. Known Error

CR 1-253216392

Product

MSC / MD Nastran

Corrected Version

Known Error

CR 1-253216392

Abstract

EFEA No account of beam orientations

Description

If a beam has either asymmetric section properties or is not oriented aligned with the basic coordinate system, this information does not get transported to the model-all.dat file - for example, the model-all.dat file is not changed by a change in beam orientation on the CBEAM entry. Of course, one solution would be to modify the PBAR properties, but in a model that contains many stiffeners this would be a large amount of work, work which has already been carried out in the model definition phase.

Known Error

CR 1-253515959

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Description

No stop after failed projection, job with chkrun=2 Model contains CWELDs with ELEMID and ELPAT two of the ELPATs don't work, UFM 7635 (MDG2ED) but job continues to run if chkrun=2 is specified on swldprm chkrun=0 or 1 stops as expected The job should also stop if chkrun=2 is requested.

Known Error

CR 1-253725753

Product

MSC / MD Nastran

Corrected Version GL Abstract

limit on intrinsic functions, SWM 203(PRCFOI) Intrinsic functions MAX and MIN are limited to 0) DIAGONAL FORSCALO/FORPWR/'WHOLE'/PWR $ IF (ANYSTR>0) DIAGONAL STRSCALO/STRPWR/'WHOLE'/PWR $ ENDALTER $ ECHOON $

Known Error

CR 1-258161471

Product

MSC / MD Nastran

Corrected Version GL Abstract

SOL 200 sensitivity on mass moment of inertia in rotordynamic is incorrect

Description

SOL 200 sensitivity on Ixx, mass moment of inertia, terms in rotordynamic is incorrect. In rotordynamic, Ixx produces damping terms which is not properly handled in Ixx perturbation. Avodiance: None.

Known Error

CR 1-258234412

Product

MSC / MD Nastran

Corrected Version GL Abstract

SOL106 with Temprature LBCs and Large displacement ON, modes are not correct

Description

When SOL 106 or 400 are used to perform nonlinear analysis, followed by perturbation analysis about the converged solution, it is essential to ensure the matrices are updated to the converges solution. The best way to insure this is to select a method like "ITER-1" or "PNT". The "AUTO" method is likely to geve poor results for the ensuing perturbation analusis. Perturbation types supported are vibration modes, nonlinear buckling and dynamic response.

Known Error

CR 1-258246641

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

The transverse shear for composites was not accurate

Known Error

CR 1-258246641

Description

If PCOMP records are used, Nastran used to calculate the transverse shear flexibility wrong. The fix for CR 1-20376918 did not always work. This should have only a minor effect upon results (greatest effect is for thick shells).

Known Error

CR 1-258297685

Product

MSC / MD Nastran

Corrected Version Abstract

UFM6352 (CELADCOB) with "adaptive mesh". A model with HADAPT may fail with the following message:

Description

*** USER FATAL MESSAGE 6352 (CELADCOB) LOGIC ERROR: 2 USER ACTION: CONTACT MSC.SOFTWARE CLIENT SUPPORT. USER INFORMATION: Too many elements meet at a face. The mesh is not suitable for mesh refinement -----------------------------------As the error message briefly explains, this specific mesh is not suitable for mesh refinement. There are 'superposed' 3D elements which make refinement impossible using the current algorithms.

Known Error

CR 1-258478452

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

PARAM,AUTOMSET,YES ignored in SOL400 when RIGID=LINEAR When using the RIGID=LINEAR case control command, in both linear statics and SOL400, it is telling the program to use the linear fomulation of the rigid elements... in SOL101, the PARAM,AUTOMSET,YES takes care of any mutually dependent DOF issues.

Description

In SOL400, where RIGID=LINEAR is used, the PARAM is ignored. But, if you change to RIGID=LAGR (which is the default in SOL400), then the job will solve... this is because the lagrangian formulation of the rigid elements doesn't put the dependent DOF into the MSET, but into the LM set, which remains in the solution set.

Known Error

CR 1-258478801

Product

MSC / MD Nastran

Corrected Version Abstract

MDr3 QRG VCCT bulk data entry remark 8 refers to "n1", but this hsould be

Known Error

CR 1-258478801 "G1"

Description

The MDr3 QRG VCCT bulk data entry in remark 8 makes a reference to "n1", but this should be "G1".

Known Error

CR 1-258498871

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Bulk Data TSTEPNL Remark 1 There is following description in remark 1 in TSTEPNL.

Description

"Multiple subcases are assumed to occur sequentially in time with the initial values of time and displacement conditions of each subcase defined by the end conditions of the previous subcase." This is correct for SOLs 129 and 159 only. "Subcase" should be changed to "STEP" for SOL 400. And it should be shown that each subcases are independent for SOL 400.

Known Error

CR 1-258524461

Product

MSC / MD Nastran

Corrected Version 2010.1.0 (MD R4) Abstract

Bulkdata TSTEPNL remark 15 Remark 15 of TSTEPNL should be updated as follows:

Description

MAXR is used to define the upper and lower bounds for adjusted time step size, i.e., MIN( DT/(MAXBIS) , (DT/(MAXR) ) -1 ) umerge uset,nzys,/nzyx/'g'/'s' $ call CFORCE USET, ,yst,,Msh,,Bsh,, KSh,k4sh,,kdsh,,ol,,a1sh, cases,dynamics,dit,vgfs,vfs,nzyx/ pyxt/ APP/APP/'enforce'/true/false/fs/fonly $ compile spdr1 alter 'if ( mdreig and novgfs','' dbstatus vpg//s,n,novpg $ if ( mdreig and novgfs>0 and noz01dr0>0 and novpg
View more...

Comments

Copyright ©2017 KUPDF Inc.
SUPPORT KUPDF