7.236 m (1.29*3.5^2/2+(6.41-1.29)*3.5^2/6)/((1.29+6.41)/2*3.5)+3.5
4.863 m (6.41*3.5^2/2+(7.6-6.41)*3.5^2/6)/(6.41+7.6)/2*3.5)
1.625 m
M = 119.57 tn-m Mu = 1.6*M Mu = 191.315 Tn-m
C.G. = M/P =119.572/43.036 Yg = 2.778 m
DIMENSIONAMIENTO DE LA PANTALLA: Calculo de t1: t1 >= 0.25m t1 = 0.300 m Calculo de t2: b = 1.000 m ρ = 0.004 m φ = 0.900 m
43.036 tn-m2
Yg = 2.778 m
w = ρ*fy/f´c w = 0.08 Mu = φ*b*d^2*f`c*w(1-0.59w) 191.315*10^5 = 0.9*100*d^2*210*0.08*(1-0.59*0.08) d = 115.239 cm t2 = d +rec +Øb/2 t2 = 1.200 m Usar:
CONSTRUCTORA CGR INGENIERIA CONSTRUCCION SAC TACNA - PERU
asumiendo: Ø Nº3 = 1.590 cm
t2 = 1.30 m
d = 1.25 m
ELIZABEHT G. ZEBALLOS HUAMANI ING. CIVIL CIP 124611
DISEÑO DE MURO DE CONTENCION CON CONTRAFUERTE Verificación por Corte: 9.89 Tn/m2
8.848 Tn/m2 6.41 Tn/m2
43.036Tn 43.036Tn
1,05
2,45
Y
3,5
P..(1.05) = (9.89-6.41)/3.5*2.45+6.41 P..(1.05) = 8.649 Tn/m2 Y = 43.036- (8.848+9.89)/2*1.05 Y = 31.428 Tn/m
Vud = 1.6*Vd Vud = 50.284 Tn/m
Vc = 0.53*f´c^1/2*b*d Vc = 96.163 Tn/m
ΦVc = 0.85*80.802 ΦVc = 81.738 Tn/m ok¡ cumple
ΦVc >= Vud DIMENSIONAMIENTO DE LA ZAPATA: hz = t2 +5cm hz = 1.35 m h = hz + hp h = 9.85 m Dimensionamiento por estabilidad al deslizamiento: P = (9.89-6.41)/3.5*4.65+6.41 P = 11.24 tn-m2 P1 =0.00tn-m 1 0,5
ELIZABEHT G. ZEBALLOS HUAMANI ING. CIVIL CIP 124611
DISEÑO DE MURO DE CONTENCION CON CONTRAFUERTE
Yg = 3.265 m
Ha = P = 57.300 Tn Mº = 187.095 Tn-m DATOS: Ým = f= Ka = Ýs = FSD = FSV =
2.00 tn-m3 0.6 0.490 º 1900 kg/m3 1.5 1.75
Dimensionamiento por estabilidad al Deslizamiento: Hr = f*Pm Hr = f*Ým*B1*H Ha = 57.3 T/m
Pm
9.85 m
Ha = 57.30 Tn/m
Hr / Ha >= FSD = 1.5 B1 >= 57.3*1.5/(0.6*2*9.85) B1 >= 7.27 m
3.265 m
Hr
Usar :
B1 =
B1
7.30 m
Dimensionamiento por estabilidad al Volteo: Aplicando Mº en "A" Mo = Ha*Yg Mo = 57.3*3.625 Mo = 187.095 Tn-m
9.85 m
Mr = Pm*(B2+B1/2) Mr = Ým*B1*H*(B2+B1/2
Ha = 57.30 Tn/m Pm`
3.265 m
A
Mr / Mo >= FSV = 1.75 (2.0*7.3*9.85*(B2+7.3/2))/187.095 >= 1.75 B2 >= -1.37 m
B2
pero: B2mín = H/10 = 0.99 m Usar :
B2 = 1.00 m
Entonces: B = B1+B2 B = 8.30 m condición:
0.5H = Vud
ok conforme ¡
Refuerzo Transversal: As temp. = 0.0018*b*t As temp. = 24.300 cm2
Ø Nº8 = A Nº8 =
s = 20.864 cm As montaje = 36*( Øb) As montaje = 57.240 cm2
2.540 cm 5.070 cm2 usar: Ø Nº8 @ 0.20m
Ø Nº5 = A Nº5 =
1.590 cm 1.980 cm2 usar: Ø Nº5 @ 0.50m
CONSTRUCTORA CGR INGENIERIA CONSTRUCCION SAC TACNA - PERU
ELIZABEHT G. ZEBALLOS HUAMANI ING. CIVIL CIP 124611
DISEÑO DE MURO DE CONTENCION CON CONTRAFUERTE
DISEÑO DE LA PANTALLA: Contrafuerte
-As
Franjas Horizontales L/3
L`
L
L/3
+As
L = 3.20m
P -As
3L/8
P` = 57.300 Tn L = 3.500 m P = P`/L*(L-3L/8) P = 35.813 Tn Acero Horizontal: Momentos para el diseño: (+)M = PL^2/16 (+)M = 27.42 tn-m
(-)M = PL^2/12 (-)M = 36.56 tn-m
Para (+)Mº : (+)M = 27.42 tn-m donde: As = Mu/(φ*fy*(d-a/2)) a = As*fy/(0.85*f´c*b) a = d/5 = a= a= a=
25.041 cm 1.515 cm 1.371 cm 1.371 cm
As = As = As = As =
6.437 cm2 5.829 cm2 5.825 cm2 5.825 cm2
φ = 0.9 fy = 4200 Kg/cm2 f´c = 210 Kg/cm2 d = 125.205 cm b = 100.000 cm Ø Nº8 = 2.540 cm A Nº8 = 5.070 cm2
As = 5.825 cm2 As mín = 0.0018*b*d As mín = 22.537 cm2 s = 22.496 cm usar: Ø Nº8 @ 0.22m
CONSTRUCTORA CGR INGENIERIA CONSTRUCCION SAC TACNA - PERU
ELIZABEHT G. ZEBALLOS HUAMANI ING. CIVIL CIP 124611
DISEÑO DE MURO DE CONTENCION CON CONTRAFUERTE Para (+)Mº : (-)M = 36.56 tn-m donde: As = Mu/(φ*fy*(d-a/2)) a = As*fy/(0.85*f´c*b) a = d/5 = a= a= a=
25.041 cm 2.020 cm 1.832 cm 1.831 cm
As = As = As = As =
8.583 cm2 7.787 cm2 7.782 cm2 7.782 cm2
φ = 0.9 fy = 4200 Kg/cm2 f´c = 210 Kg/cm2 d = 125.205 cm b = 100.000 cm Ø Nº8 = 2.540 cm A Nº8 = 5.070 cm2
As = 7.782 cm2 As mín = 0.0018*b*d As mín = 22.537 cm2 s = 22.496 cm usar: Ø Nº8 @ 0.22m Acero Vertical:
+M +As
-M L /3
-A s
Momentos para el diseño: (-)M = 0.06*P`*L (-)M = 12.03 tn-m
(+)M = (-)M/4 (+)M = 3.01 tn-m
Para (-)Mº : (-)M = 12.03 tn-m donde: As = Mu/(φ*fy*(d-a/2)) a = As*fy/(0.85*f´c*b) a = d/5 = a= a= a=
25.041 cm 0.665 cm 0.030 cm 0.018 cm
As = As = As = As =
2.825 cm2 2.549 cm2 2.543 cm2 2.543 cm2
φ = 0.9 fy = 4200 Kg/cm2 f´c = 210 Kg/cm2 d = 125.205 cm b = 100.000 cm Ø Nº8 = 2.540 cm A Nº8 = 5.070 cm2
As = 2.543 cm2 As mín = 0.0018*b*d As mín = 22.537 cm2 s = 22.496 cm
CONSTRUCTORA CGR INGENIERIA CONSTRUCCION SAC TACNA - PERU
usar: Ø Nº8 @ 0.22m
ELIZABEHT G. ZEBALLOS HUAMANI ING. CIVIL CIP 124611
DISEÑO DE MURO DE CONTENCION CON CONTRAFUERTE Para (+)Mº : (+)M = 3.01 tn-m donde: As = Mu/(φ*fy*(d-a/2)) a = As*fy/(0.85*f´c*b) As = 0.706 cm2 As = 0.636 cm2 As = 0.636 cm2
a = d/5 = 25.041 cm a = 0.166 cm a = 0.150 cm
φ = 0.9 fy = 4200 Kg/cm2 f´c = 210 Kg/cm2 d = 125.205 cm b = 100.000 cm Ø Nº8 = 2.540 cm A Nº8 = 5.070 cm2
As = 0.636 cm2 As mín = 0.0018*b*d As mín = 22.537 cm2 s = 22.496 cm usar: Ø Nº8 @ 0.22m
DISEÑO DE LOS CONTRAFUERTES: Por Flexión:
Mu
?
hp
As
PhpL
t2/2 jd
Tu Tu Cos? d
CONSTRUCTORA CGR INGENIERIA CONSTRUCCION SAC TACNA - PERU
ELIZABEHT G. ZEBALLOS HUAMANI ING. CIVIL CIP 124611
DISEÑO DE MURO DE CONTENCION CON CONTRAFUERTE TOMANDO DATOS ANTERIOERES: P1 =0.00tn-m
SECCION ANALIZADA Mu (Tn-m) Vu (Tn/m) d (cm) Tu (Tn) As (cm2) Nº varillas
A UN TERCIO DE LA ALTURA 121.936 Tn-m 32.049 Tn-m 7*567/850+30-6 490.67 cm 35.062 Tn 9.28 cm2 2 Nº8
EN LA BASE 119.572 Tn-m 31.428 Tn/m 730-6 724.00 cm 22.209 Tn 5.88 cm2 3 Nº5
AL CENTRO 182.904 Tn-m 48.074 Tn-m 7*425/850+30-6 374.00 cm 72.451 Tn 19.17 cm2 4 Nº8
En un contrafuerte no puede haber espaciamiento de 20cm, por lo que se le aumenta a 35cm El refuerzo transversal se calcula de acuerdo a las reacciones que esta ejerce sobre la pantalla vertical: Tu = 3/2*M h = 35
donde M = 12.03 tn-m Tu = 2.235 Tn As = 0.59 cm2 s=
CONSTRUCTORA CGR INGENIERIA CONSTRUCCION SAC TACNA - PERU