MS-1553

November 13, 2016 | Author: Prapa Karan | Category: N/A
Share Embed Donate


Short Description

MS1553...

Description

Licensed to T G Tan \& Partners Sdn Bhd / Downloaded on : 08-Nov-2010 07:52:04 PM / Single user license only, copying and networking prohibited

MALAYSIAN STANDARD

MS 1553 : 2002

CODE OF PRACTICE ON WIND LOADING FOR BUILDING STRUCTURE

ICS : 91.090 Descriptors :

building structure, wind loading, wind action, wind speed, wind pressure, site exposure multipliers, shape factor

© Copyright DEPARTMENT OF STANDARDS MALAYSIA

DEVELOPMENT OF MALAYSIAN STANDARDS The Department of Standards Malaysia (DSM) is the national standardisation and accreditation body. The main function of the Department is to foster and promote standards, standardisation and accreditation as a means of advancing the national economy,

Licensed to T G Tan \& Partners Sdn Bhd / Downloaded on : 08-Nov-2010 07:52:04 PM / Single user license only, copying and networking prohibited

promoting industrial efficiency and development, benefiting the health and safety of the public, protecting the consumers, facilitating domestic and international trade and furthering international cooperation in relation to standards and standardisation. Malaysian Standards are developed through consensus by committees which comprise of balanced representation of producers, users, consumers and others with relevant interests, as may be appropriate to the subject in hand. To the greatest extent possible, Malaysian Standards are aligned to or are adoption of international standards. Approval of a standard as a Malaysian Standard is governed by the Standards of Malaysia Act 1996 (Act 549). Malaysian Standards are reviewed periodically. The use of Malaysian Standards is voluntary except in so far as they are made mandatory by regulatory authorities by means of regulations, local by-laws or any other similar ways. The Department of Standards appoints SIRIM Berhad as the agent to develop Malaysian Standards. The Department also appoints SIRIM Berhad as the agent for distribution and sale of Malaysian Standards. For further information on Malaysian Standards, please contact: Department of Standards Malaysia Level 1 & 2, Block C4, Parcel C Federal Government Administrative Centre 62502 Putrajaya MALAYSIA

OR

SIRIM Berhad (Company No. 367474 - V) 1, Persiaran Dato’ Menteri P.O. Box 7035, Section 2 40911 Shah Alam Selangor D.E.

Tel: 60 3 88858000 Fax: 60 3 88885060

Tel: 60 3 5544 6000 Fax: 60 3 4410 8095

http://www.dsm.gov.my

http://www.sirim.my

E-mail: [email protected]

MS 1553 : 2002

CONTENTS

Licensed to T G Tan \& Partners Sdn Bhd / Downloaded on : 08-Nov-2010 07:52:04 PM / Single user license only, copying and networking prohibited

Page Committee representation……………………………………………………………………...

v

Foreword………………………………………………………………………………………...

vi

SECTION 1 : GENERAL 1.1 1.2 1.3 1.4 1.5 1.6 1.7

Scope………………………………………………………………………….……….... Application…………………………………………………………….……..…….…… Referenced documents…………………………………………………….……….…. Determination of wind actions…………………………………………..……………. Units…………………………………………………………………………….….……. Definitions……………………………………………………………………….……… Notation…………………………………………………………………………………

1 1 1 1 2 2 6

SECTION 2 : CALCULATION OF WIND ACTIONS 2.1 2.2 2.3 2.4 2.5 2.6 2.7 .

General…………………………………………………..……………………..……… Site wind speed………………………………………………………………..………. Design wind speed…………………………………………………………………... Design wind pressure………………………………………………………………... Wind actions……………………………………………………………………..….... Wind tunnel procedure………………………………………………….…..…..……. Wind induced vibrations…………………………………………………….…..……

14 14 15 15 16 17 18

SECTION 3 : WIND SPEEDS 3.1 3.2

General …………………………………………………………………………..…....… 19 Station wind speeds…………………………………………………………….…….. 19

SECTION 4 : SITE EXPOSURE MULTIPLIERS 4.1 4.2 4.3 4.4

General ………………………………………………………………….……..…….…. Terrain/height multiplier, mz,cat …………………………………………………..…… Shielding multiplier, ms …………………………………………………………….….. Hill shape multiplier, mh………………………………………………………….…….

22 22 25 26

SECTION 5 : AERODYNAMIC SHAPE FACTOR 5.1 5.2 5.3 5.4 5.5

General……………………………………………………………………………..…. Evaluation of aerodynamic shape factor……………………………………..……. Internal pressure for enclosed buildings………………………………………..…. External pressures for enclosed buildings…………………………..………..…… Frictional drag forces for enclosed buildings………………………………….……

i

29 30 31 33 41

MS 1553 : 2002

CONTENTS (continued) Page

Licensed to T G Tan \& Partners Sdn Bhd / Downloaded on : 08-Nov-2010 07:52:04 PM / Single user license only, copying and networking prohibited

SECTION 6 : DYNAMIC RESPONSE FACTOR 6.1 6.2 6.3 6.4

Evaluation of dynamic response factor………………………….…………………… Along-wind response of tall buildings and towers……………………………….…. Cross wind response………………………………..…………………………….…… Combination of along wind and crosswind response…………………………..….

43 43 47 53

Wind speed for various return period…………………………………………..……. Importance factor, I…………………………………………………………………..… Terrain/height multipliers for gust wind speeds in fully developed terrain. Serviceability limit state design and ultimate limit state……………………….…... Roughness lengths for terrain categories………………………………………..….. Shielding multiplier, Ms………………………………………………………………………………………………..…. Hill-shape multiplier at crest ( |x| = 0), z = 0 (for gust wind speeds)…………….... Internal pressure, coefficients, Cp,i, for buildings with open interior plan………... Wall : External pressure coefficients, Cp,e for rectangular enclosed buildings … Roofs : External pressure coefficients, Cp,e, for rectangular enclosed buildings ... Area reduction factor, Ka………………………………………………………………………………………………….. Action combination factors for wind pressure contributing from two or more building surfaces to effects on major structural elements………………. Local pressure factor, Kl ………………………………………………………………. Reduction factor, Kr, due to parapets……………………………………………….. Porous cladding reduction factor, Kp………………………………………………… Frictional drag coefficient for d/h > 4 or d/b > 4…………………………………….. Turbulence intensity (Iz) ultimate limit state design and serviceability limit state design – all regions ………………………………………………………. Values of fraction critical damping of structures (ζ) ……………………………… Terrain height multiplier, Mz,cat ……………………………………………………. External pressure coefficients Cp,e, for leeward wall ……………………………. External pressure coefficients Cp,e, for side walls ……………………………….

19 21

For up-wind slope, u and down-wind slope, d for α
View more...

Comments

Copyright ©2017 KUPDF Inc.
SUPPORT KUPDF